Loading...
HomeMy WebLinkAboutPermit D11-224 - HATTON RESIDENCE - UPGRADESHATTON RESIDENCE 3935 S 113 ST EXPIRED 03 -12 -12 Dl 1 -224 City �ukwila S Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3351400105 Address: 3935 S 113 ST TUKW Suite No: Project Name: HATTON RESIDENCE DEVELOPMENT PERMIT Permit Number: D11 -224 Issue Date: 09/14/2011 Permit Expires On: 03/12/2012 Owner: Name: HATTON RALPH L Address: 3935 S 113TH , SEATTLE WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI919OA Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $29,458.00 Fees Collected: $1,092.10 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -224 Printed: 09 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied N Private: Public: Profit: N Non - Profit: N Private: Public: II Ii'' Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pre construction or the performance of to this permit. Signature: to give authority to violate or cancel the provisions of any other state or local laws regulating . I am authorized to sign and obtain this development permit and agree to the conditions attached Date: WO (i) Print Name: -3-6...4c 4 )%(1 -/= This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11 -224 Printed: 09 -14 -2011 this reauireinnt. • 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -224 Printed: 09 -14 -2011 CITY OF TUKWILA) Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Building Permit°. blt, 1Z- Mechanical Permit No Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3935 S. 113th St. Tenant Name: Ralph L. Hatton Property Owners Name: Ralph L. Hatton Mailing Address: 3935 S. 113th St. King Co Assessor's Tax No.: 3351400105 Suite Number: Floor: New Tenant: ❑ Yes ®..No Seattle WA 98168 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION = (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: H: Applications\Porms- Applications On Line\2009 Applications \1 -2009 - Pe,mit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFOR 'i ION — 206 - 431 -3670 0 Valuation of Project (contractor's bid price): $ 29,458 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If ' yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H :'Applications \Forms- Applications Ooline\2009 Applications4-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 1,022 2nd Floor 3rd Floor Floors thru Basement 250 Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If ' yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H :'Applications \Forms- Applications Ooline\2009 Applications4-2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PLUMBING AND GAS PIPIN(.ERMIT INFORMATION — 206 -437 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR _ • ' ED AGENT: Signature: Date: Print Name: othy J. Fen : s• , SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777 Mailing Address: 4000 Delri. ,e Way SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: ( Date Application Expires: 1 (, Staff Initials: H:'Applications •.Forms - Applications On Line,2009 Applications \1-2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 CitlOof Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: htiv. //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011 RECEIPT NO: R11 -01600 Initials: WER Payment Date: 07/28/2011 User ID: 1655 Total Payment: 13,064.48 Payee: PAMELA K KUEHL SET ID: 071911 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D11 -222 748.15 D11 -223 716.64 D11 -224 1,092.10 D11 -225 993.76 D11 -226 622.10 D11 -227 653.61 D11 -228 1,067.51 D11 -229 685.13 D11 -230 685.13 D11 -231 716.64 D11 -232 1,018.34 D11 -233 559.07 D11 -234 811.18 D11 -235 1,042.93 D11 -236 1,652.19 TOTAL: —/487t5-- TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,064.48 TOTAL: 13,064.48 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 7,876.95 000.345.830 5,120.03 640.237.114 67.50 TOTAL: 13,064.48 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D11 -224 HATTON RESIDENCE 3935 S 113 ST TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall it Technician File: Permit File No. D11 -224 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PE a C�� PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -224 PROJECT NAME: HATTON RESIDENCE SITE ADDRESS: 3935 S 113 ST X Original Plan Submittal Response to Correction Letter # DATE: 07 -19 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: i ` 'vision ` l ul ding Ilvlsion �� Pub 'v IPA tn.7' Pb is or A- ire Prevention Structural P ming Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete ❑ DUE DATE: 07-21-11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 08-18-11 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 1 • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCC19190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135245 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.0003 /07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: Mechanical ectrical numbing as Pip#ng City of Tukwila Rol DING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. '777: ro visions will require a new plan submittal crdd may include additional plan review fees. FI COPY Li Permit No., .1 �" 2ZI Pun revi3w approval is subject to errors and omissions. kp :. ;roval of construction documents does not authorize th violation of any adopted code or ordinance. Receipt os approved Fiel edged: City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 A-7- City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION ,JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3351400105 ZONING: 5F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Charge) Y B NON SPRINKLERED LEGAL DESCRIPTION: HILLMANS C D MEADOW GARDENS* 3 TGW POR VAC 40TH AVE 5 ADJ DUILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: MAR ,1 22012 DRAWING INDEX Told AI.O A2.0 A2.1 422 423 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS MI.0 LEGENDS, SCHEDULES, ABBRI=v., GENERAL NOTES 4 DWG INDEX M20 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 95108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: SharynParkerekingcounty. ov ARCHITECT: S.M. Stemper Architects PLL.C. 4000 Delrldge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryeametemper.com melody esmstemper.com tlmesmstemper.com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. S39. 0S19 Fax: 206. ass. 0824 Contact: Mohamed Alt Allaoua Contact: Brent Rollin E -mail: mohamedessaacousticscom E -mail: bcretreswest.com ELECTRICAL ENINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 58409 Ph: 253. 412. 3300 Fax: 253.412.3463 MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle, WA 98119 Ph: 206.31S. 0569 Fax: 206.318.0641 Contact: Chris Agar E -mail: ChrlsAegreenbuschcom REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4100 Contact: Tim Ogden E -mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. ii200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwelleJonespayne.com VICINITY MAP (NTS) D1 214 ECEIVED JUL 19 2011 PL {'. f.TO LATER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (206) 624 -2873 REGISTERED. scoTT 1 TEMPE STATE OF 11 1- NGTON 0810.03.1734 2/24/11 MPROVEMENTS KING COUNTY AIP NUMBER 5- 53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1734 STORAGE FUR ' LL FAMILY ROOM BASEMENT PLAN 1/4" = 1' NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT I5 PRESENT AT TI-115 RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. KITCHEN NORTH BATH LIVING ROOM - 18" x 1S" EXIST. ATTIC ACCESS PANEL A PRI 0 R TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OuNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK„ PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECT. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POUER OUTAGE IS EIGHT HOGS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. 4 AFTER 5:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WI -IERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 1- N O 0 C ET !BEDROOM BEDROOM 2 MAIN FLOOR PLAN 1/4" = 1' o< 12' -1" 21' -3" cfl r TYF'. r J 1 1 • I. r . . . _ . . . _ . . . . J NEU12j " x 24 "- . . ATTI ACCESS V 11 I = = `.18 ".x 18" EXIST.1 . ATTIC ACCESS! - PANEL _JI I11 C� ru NN NIN N N r1 I I r l r I / Cr /1 II 1 II 1 u I 1 r L I n \\ 1 I -I L- - - -1 1 �� L E.-- .. - 7iki=TT-T-T1 R - -�1 . r , I 4 I - - I - I I - II - I -1 1 1, I- I . I- /I� 1I H - - • /1 I• II. I- I - I -I - I -I -I - - - -/. -1 -�`- - -1.1 - . . . - - - - 11- - - /I- 1.1.11.1 -I i F I- I-1- - -1 I 1- - - - - - - -- y -\ I r A/ CC 1 r 1 1 /___I 7 r- ---Li r L-- _ -ft T. ATTIC PLAN 1 /4" = 1' A. WEST ELEVATION B. NORTH ELEVATION PLAN KEYNOTES EDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOMS), FRAME, CASING, AND THRESHOLD. INSTA -L NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 42.1 ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR PETAL. COORDINATE WITH MECHANICAL. G:: INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER. OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/A22 FOR DETAIL. 0 ADDITIONAL SUPPORT AT BAY WINDOW REQUIRED REF. DETAIL 5/422 FOR DETAIL. OSURPLUS (E) DOOR HARDWARE PER HOMEOWNERS REQUEST. OAT (E) BAY WINDOW AREA, INSTALL 2X WOOD FRAMING AT ROUGH OPENINGS TO SUPPORT INSTALLATION OF NEW WINDOWS. REF. 1/A22 FOR STRUCTURAL SUPPORT DETAIL BELOW SILL. pl.,,,.., 21. ACCESS TO SITE AND PARKING I ,, r , .1 l BEDROOM 2 MAIN FLOOR PLAN 1/4" = 1' o< 12' -1" 21' -3" cfl r TYF'. r J 1 1 • I. r . . . _ . . . _ . . . . J NEU12j " x 24 "- . . ATTI ACCESS V 11 I = = `.18 ".x 18" EXIST.1 . ATTIC ACCESS! - PANEL _JI I11 C� ru NN NIN N N r1 I I r l r I / Cr /1 II 1 II 1 u I 1 r L I n \\ 1 I -I L- - - -1 1 �� L E.-- .. - 7iki=TT-T-T1 R - -�1 . r , I 4 I - - I - I I - II - I -1 1 1, I- I . I- /I� 1I H - - • /1 I• II. I- I - I -I - I -I -I - - - -/. -1 -�`- - -1.1 - . . . - - - - 11- - - /I- 1.1.11.1 -I i F I- I-1- - -1 I 1- - - - - - - -- y -\ I r A/ CC 1 r 1 1 /___I 7 r- ---Li r L-- _ -ft T. ATTIC PLAN 1 /4" = 1' A. WEST ELEVATION B. NORTH ELEVATION PLAN KEYNOTES EDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOMS), FRAME, CASING, AND THRESHOLD. INSTA -L NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 42.1 ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR PETAL. COORDINATE WITH MECHANICAL. G:: INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER. OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/A22 FOR DETAIL. 0 ADDITIONAL SUPPORT AT BAY WINDOW REQUIRED REF. DETAIL 5/422 FOR DETAIL. OSURPLUS (E) DOOR HARDWARE PER HOMEOWNERS REQUEST. OAT (E) BAY WINDOW AREA, INSTALL 2X WOOD FRAMING AT ROUGH OPENINGS TO SUPPORT INSTALLATION OF NEW WINDOWS. REF. 1/A22 FOR STRUCTURAL SUPPORT DETAIL BELOW SILL. pl.,,,.., 21. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. EAST ELEVATION 1- l r N MAR 1 : 22012 1 D. SOUTH ELEVATION LEGEND ACOUSTICAL WINDOW E[Y T NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. 42.0 SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL EXISTING KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED NOT USED NOT USED ATTIC INSULATION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISIOF,: RECEIVED JUL 19 2011 PE +,TC CENTER AS SD INSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE Qg GAS METER I�!�I S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A;'HITECT COTT 1 STATE OF 0810.03.1734 TEMP SHINGTON • 2/24/11 0 LL ct -J ct T O z W 1- z KING COUNTY AIP NUMBER MPROVEMENTS 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1734 WINDOW TYPES SINGLE HUNG 2 FIXED 3 SLIDER 4 SLIDER / SLIDER / FIXED SLIDER / FIXED / SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A KITCHEN 2 4' -0" x 4' -5" PAINT/PAINT SAFETY GLAZING 1/42.0 B KITCHEN 5 9' -I0" x 4' -5" PAINT/PAINT I/42.0 C KITCHEN 3 5' -0" x 2' -I0" PAINT/PAINT I/42.0 D LIVING ROOM 3 5' -3" x 4' -3" PAINT/PAINT 1/420 E LIVING ROOM 1 2' -4" x 4' -10" PAINT/PAINT SAFETY GLAZING 3 /A2.0 F LIVING ROOM 2 5' -2" x 4' -10" PAINT/PAINT SAFETY GLAZING 3/42.0 G LIVING ROOM I 2' -4" x 4' -10" PAINT/PAINT SAFETY GLAZING 3/42.0 H BEDROOM 1 3 4' -I0" x 4' -0" PAINT/PAINT Y I /42.0 I BEDROOM 1 3 4' -1" x 4' -3" PAINT/PAINT I /42.0 J BEDROOM 2 3 4' -l" x 4' -3" PAINT/PAINT Y I /A2.0 K FAMILY ROOM 4 10' -1" x 2' -10" PAINT/PAINT SLIDER TO MATCH WINDOW "I" 2/42.0 L FAMILY ROOM 3 4' -10" x 2' -10" PAINT/PAINT 2/42.0 M FAMILY ROOM 3 3' -10" x 2' -10" PAINT/PAINT 2/42.0 (E) • EXISTING TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING REF. PHOTO 5/A22 FOR EXISTING CONDITION (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE CF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, COOL FLUSH, AND PAINT FASTENER HEADS AND MY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT WINDOW HEAD tuD. JAMB LINING SEALANT 51-11M AS NECESSARY FILL GAP W/ BATT INSULATION ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN -- . TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING WINDOW JAMB (E) GU. WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD JAMB LINING SEALANT SHIM ,4S NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3/8" 3/4" WD. SILL - STAIN TO MATCH (E) WINDOW SILL WOOD TRIM TO MATCI4 (E), PAINT /STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GOB WOOD SIDING - WINDOW DETAIL SET 3" = 1' - 0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TIP AT HEAD AND JAMB ti REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT 70 MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY (E) WALL UNDERLAYMENT (E) WD. PANELING (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE CAREFULLY CUT SACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING, INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER LEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) IUD. SIDING WINDOW HEAD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN WINDOW JAMB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION (E) WD. PANELING WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATGH (E) TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION LI TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D t0 MAINTAIN COURSING. PAINT TO MATCH (E) SIDING (E) EXTERIOR 514EATHING (E) WD. SIDING WINDOW SILL BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM (E) WD. PANELING SELF - ADHERING MEMBRANE WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" EXIST. SIDING (E) BAY CONSTRUCTION WINDOW NAIL FIN, TYPICAL TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT SELF- ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL. s hOttitttl■ A f:. CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTRUCTION, TYPICAL SEALANT III -2-21 (2) LAYERS OF SELF- ADI- IERING MEMBRANE, TYPICAL BACKER ROD 4 SEALANT, TYPICAL ACOUSTICAL WINDOW ASSEMBLY - WINDOW NAIL FIN, TYPICAL .DOW TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT, TYPICAL HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM (E) GWB SILL AT BAY WINDOW ACOUSTICAL WINDOW ASSEMBLY CAREFULLY REMOVE (E) SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN PANEL PATTERN 4 PAINT TO MATCH (E) SIDING, TYPICAL WINDOW JAMB HARDWOOD TRIM TO MATCI4 (E), PAINT /STAIN TO MATCH (E) TRIM SELF- ADHERING MEMBRANE BACKER ROD 1 SEALANT WINDOW NAIL FIN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO 5E FIELD DETERMINED BACKER ROD 4 SEALANT WINDOW SILL CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL WOOD SIDING - BAY WINDOW DETAIL SET 3" = 1' - 0" E pi MAR 1 Z2012 REVIEWED ED CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVE[ JUL 19 2011 PERMITCENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 4220 REGISTERED A; HITE:cT ,1111" °fir CUTT STATE OF 0810.03.1734 2/24/11 TE MPE WINGTON 0 d. ce J z 0 z w 1- 0 U MPROVEMENTS 0 cw w w 0 z LL U 1- 0 w ce AIP NUMBER 5 -53- 0058 -043 0 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1734 DOOR TYPES O A FLUSH SCW W/ OBSERVATION PORT SECONDARY SLIDING GLASS DOOR W/ SAFETY GLAZING EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I KITCHEN A 2' -8" x 6'4" STAIN /SLAIN I•IW -I 1 609 DK -4 (Camelot) LOCK -1 I /A2.1 2 LIVING B I' -11" x 6' -8" 2/A2.1 3 FAMILY ROOM A 4' -0" x 6' -3" STAIN/STAIN 1 -NU) -1 / 609 DK -4 (Camelot) LOCK -1 3 /42.1 4 KITCHEN c 2' -S" x 6' -8" 1/A2.1 5 FAMILY ROOM C 4' -0" x 6' -3" 3/A2.1 TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHEN SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED N SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH TI4E OPERATION OF tHE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REM) FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STOp1 DOOR PER SCHEDULE 2" MIN. SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM DOOR HEAD CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP .T I \�11, --; pzAis Fi— ►" MI. DOOR JAMB SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 " =1' -0" (E) WD. SIDING PRE- PRIMED, GALV SHEET METAL FLASHING OVER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD SELF- ADI- IERING MEMBRANE. TURN DOWN OVER FRONT EDGE OF TRIM. ENSURE NO MEMBRANE IS VISIBLE BELOW FLASHING EDGE 2X CANTED CAP REMOVE (E) SIDING TO FACILITATE INSTALLATION OF FLASHING AND DOOR HEAD ASSEMBLY TRIM- PAINT TO MATCH (E) TRIM CONTINUOUS 2x SOLID BLOCKING AROUND PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS (E) BLDG. PAPER BACKER ROD AND SEALANT SELF- ADI4EARING MEMBRANE TRIM- PAINT TO MATCH (E) TRIM DOOR HEAD (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF - ADHERING MEMBRANE REMOVE (E) WOOD SIDING AND REPLACE AS REQ'D. CAREFULLY LIFT (E) WALL UNDERLAYMENT MD INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. EXTEND SELF - ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. AT I4EA0 AND JAMB (E) PRIMARY SLIDING DOOR ASSEMBLY. PRE- PRIMED GALV. FRY REVEAL TRIM CONTINUOUS 2x SOLID BLOCKING AROUN PERIMETER OF DOOR FRAME. PAINT ALL EXPOSED EDGES TO MATCH (E) TRIM SELF- ADHERING MEMBRANE SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS WD. TRIM BEYOND SECONDARY SLIDING STORM DOOR ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS SEALANT EXISTING GRADE OR SUBSTRATE i" MIN. BETWEEN PRIMART AND SECONDARY SLIDING GLASS DOOR FRAMES DOOR JAMB (E) BEVELED WD. SIDING (E) EXTERIOR SHEATHING LIFT (E) WALL UNDERLAYMENT. LAP NEW UNDERLAYMENT UNDER (E) UNDERLAYMENT 2" AND CONTINUE OVER SLIDING GLASS DOOR FRAME (E) PRIMARY SLIDING GLASS DOOR (E) SLIDING GLASS DOOR (E) FINISH FLOOR (E) INTERIOR CONC. SLAB. OR (E) WD. FLOOR FRAMING DOOR SILL WOOD SIDING - DOOR DETAIL SET 3" = 1' -0" (E) WD. BIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF-ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. SELF- ADl- 4ERING MEMBRANE (E) EXTERIOR SHEATHING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING J CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEAT14ER- STRIPPING DOOR JAMB HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR 6140E 2" MIN, AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE (E) EXTERIOR SHEATHING EXISTING FRAMING WOOD TRIM TO MATCH (E), FAINT/STAIN TO MATCH (E) TRIM 514IM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR SILL DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 " =1' -0" MAR 1 2 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City Of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 COTT ` W'T.EM4PE. :STATE .,HINGTON 0810.03.1734 2/24/11 0 J 0 Z W z z 0 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1734 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP. AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF- ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. FIELD PAINT FLASHING - COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. 11 11 SINGLE -FRAME WINDOW ASSEMBLY. (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES AIR INTAKE DETAIL AT EXTERIOR 3 =1 -0 PIVOT HINGE CAULKING ADHESIVE INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS 0 24" O.C. EXTEND BLOCKING TO (E) CEILING JOISTS (TYP) (E) GWB SNAP FRICTION CATCH REMOVABLE DOOR PAINT DOOR AND FRAME TO MATCH (E) COLOR OF CEILING ATTIC ACCESS HATCH DETAIL 3 " =1' -0" BACKER ROD 4 SEALANT SELF - ADHERING MEMBRANE CUT (E) WOOD PANELING AS REQ'D TO INSTALL WINDOW ASSEMBLY. REPLACE AND MATCH (E) PANELING WHERE DAMAGED DURING CONSTR, TYPICAL WINDOW NAILING FIN BAY TRIM- DIME ALL SIDES AND PAINT TO MATCH (E) TRIM. ALLOW 1/2" CLEARANCE TO WINDOW FRAME FOR SEALANT JOINT METAL BRACKET± MIN. (2) PER BAY APRON TO MATCH EXIST. SIDING 2X WOOD LEDGER± INSTALL BLOCKING AT EXIST. WALL FOR ADDITIONAL SUPPORT BACKER ROD ANS SEALANT EXIST. SIDING BAY WINDOW STRUCTURE DETAIL 3 " =1' -0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 " =1' -0" INSULATION INSULATION DAM (E) WALL FRAMING TRIM PHOTO DETAIL NTS EXISTING CEILING STRUCTURE FINISH TO MATCH (E) PAINT AND TEXTURE SELF - ADHERING MEMBRANE TO WRAP ENTIRE CORNER POST ACOUSTICAL WINDOW ASSEMBLY X Ix ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING TO LEDGER DUCTS PER PLAN WITHIN SOFFIT RE: MECHANICAL 2x2 CONT. NAILER 5le" GM- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR / TERMINATE EDGE W/ AD.) ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL DUCT SOFFIT DETAIL 1 -1/2" = 1' - 0" (E) WD FRAME WALL ASSEMBLY CORNER POST DETAIL VINYL COVER TRIM TO MATCH WINDOW ASSEMBLY UNIT CONTINUOUS SEALANT AT PERIMETER OF WINDOW FRAME NEW SOLID P.T. BLOCKING (2) SIDES AROUND PIPE COLUMN. ATTACH W/ 1/4 -20 COUNTER- SUNK SCREWS W/ WASHERS IN DRILLED AND TAPPED HOLES a 24" 0.C, TYP. INSULATION (E) PIPE COLUMN IUD. TRIM. FINISH TO MATCH EXIST. SEALANT AND BACKER ROD, TYP. 3 " =1' -0" MAR 1 22012 tilt REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of TulzwilE BUILDING DIVISION ECEIVED JUL 19 2011 TC NTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 90106 (208) 624 -2777 • FAX (208) 824 -2973 REGISTERED A . HITECT 0810.03.1734 2/24/11 z W W Q Q ct >,— 4tC W O E ®C � Z Lt W 0 Z Ct Z F o 0 < 0 —I Z Q W 0 W AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1734 0 0 0 0 0 0 0 0 0 • 0 0 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR XX OR X. DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X/Y X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL $G -X xxX ABBR -ads 4-F- 0 M CD 0 R EQUIP NG ICI • D'Q DN UP VD RA /EA RG SA SA RA /EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 407 <.08 "WG 9 "4 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 180 407 <.08 "WG 9 "4 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1734 1721 2 180 CFM 180 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. 174 v-1-1 EX ED MAR 1 22012 THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 3 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) Oa &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION l/ QF = 60 / (1 X 1/3) = 180 CFM SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98100 (206) 624 -2777 • FAX (206) 624 -2273 THE GREENBUSCH GROUP, INC ■■■• • •■•■ • • • e ) 140091106.1113T AUDIO_[ vow t YEOFNNOAL UlOIEEiNR 190 N41®®wl SEW SUITE 901 SOUns. it 01110 (106) 371 -0669 (206) 378 -0641 FAX 0810.03.1734 1— rx 0 ce J z O_ z ce w F- z F- z 0 z U) w w 0 0 !>- 0 cnCw w w 0 Li- z 0 AIP NUMBER 5 -53 -0058 -043 0 GO 0 z I- Q CO DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, MM & JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1734 BEAM ROUTE DUCT IN SOFFIT AND 'TIGHT TO JOISTS STORAGE ROUTE DUCT )OWN TO POC ROUTE UNDER BEAM W SOFFI T BY OTHERS ROUTE DUCT IN JOISTS ` JOIST\ J o) CORE DRILL /CONCRETE , --C 180 UP (E)SG STORAGE BASEMENT MECHANICAL PLAN SCALE: 1/4" = 1' -0" CEILING NORTH SEE CRAWLSPACE CRAWLSPACE ACCESS ROUTE DUCT DOWN AND TIGHT TO WALL VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING MOD, INTERLOCK TO FURNACE POC FLOOR z w w 0 cL cn w FURNACE OUTSIDE AIR TO FURNACE ELEVATION OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN SCALE: NONE (E)SG KI TCI —TEN (E)SG z (E)EG LIVING ROOM (E)SG (E)SG CLOSET (E)SG BEDROOM N BEDROOM 2 O U (E)SG MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NORTH NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP CONNECTION DETAIL SCALE: NONE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY — CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2 CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. 121\ 2.2-41 EXHi'ED SEPARATE PERMIT AND APPROVAL REQUIRED MAR 1 22012 RECEIVED JUL 19 2011 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (208) 024 -2777 • FAX (zae) e24 -273 THE GREENBUSCH GROUP, INC ))) AODlsacw. VIDEO a YEOINNOI. ENOINEE1910 1100 11ef Sheer BUIE 201 9212114 1A ISI1 (208) 37s -09ee Nolo 378 -0941 FAX 0810.03.1734 KING COUNTY INTERNATIONAL AIRPORT z Li! W 0 ce 0 2 >- W Li] W 0 O z LL J W d W AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, MM & JA BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1734 15/1 /"1 BLACK L -0 0 N WHITE PANEL MP LOCATION: SERVING: EQUIPMENT CONTROL EQUIPMENT REMARKS 120/240 VOLT, 1 PHASE, 3 WIRE. BKR DESCRIPTION RESIDENCE AIC, 200 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 16 15 CKT LOAD DESCRIPTION TYPE KVA NP PHASE AP KVA TYPE LOAD DESCRIPTION CKT 1 3 5 EXIST CKT EXIST CKT X 30/2 20 A A 30/2 B 16 1,2 - EXIST CKT EXIST CKT 2 4 6 7 X — - — 15 O B 20/2 X EXIST CKT 8 9 11 13 15 17 19 EXIST CKT EXIST CKT EXIST CKT EXIST CKT EXIST CKT 15 15 15 20 I A A A B 15 20 B 30/2 13 30/2 EXIST CKT EXIST CKT EXIST CKT EXIST CKT 10 12 14 16 18 20 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH 20 20 21 EXIST CKT 30 A 22 23 25 27 29 SPACE SPACE SPACE SPACE A A B " 1511 B 0.01 0 SMOKE DETECTORS SPACE SPACE SPACE 24 26 28 30 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 0.01 0.01 KVA 0.04 AMP COMPUTED LOAD 0.01 0.01 KVA 0.04 AMP ❑ ISOLATED GROUND BUS ❑ RAINTIGHT NEMA-3R ENCLOSURE FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL PANEL SKIRTS ❑ SURFACE INTEGRAL TVSS ❑ FLUSH ■ ] ❑ ❑ REMARKS: ** PROVIDE BREAKER TO MATCH EXISTING CUTLER HAMMER PANEL MECI- ANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION TIRED UNDER DIVISION DESCRIPTION VOLTS PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X BRANCH CIRCUIT HOME RUN ®D X EJ X 1,2 - THERMOSTAT 24 1 X — - — X O THERMOSTAT X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLACK BLACK WHITE RED WHITE SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED STORRAE FUR UP STORAGE BASEMENT PLAN 1/4" = 1' ELECTRICAL LEGEND 8Yh18OL DESCRIPTION 5`fh18•L DE6CRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. I I I I 1 4 DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD S❑' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN ®D FIRE ALARM SMOKE DETECTOR 120V OPERATED EJ ELECTRICAL METER FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. TIMER OPERATED SWITCH — - — O THERMOSTAT ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOUT1ON OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES O PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. 0 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE BACK BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 120Vac AND PROVIDE COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL SEE GENERAL NOTES FOR CEILING PENETRATION REQUIREMENTS. O HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. 0 PROVIDE NEW 15/1 BREAKER IN PANEL AND 2#14 &G TYPE NMB CONDUCTOR FOR SMOKE DETECTORS TO MATCH EXISTING. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY WALL PENETRATION WORK. KITCHEN t01RJAGE D,4INPER BATH LIVING ROOM CLOSET 1- LH 0 0 15EDfsooM 2 SCPARATE P MITAND APPROVAL MAIN FLOOR PLAITEQUIRRD 1/4" = 1' MAR 1 22012 RECEIVED JUL 19 2011 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ■N.INCNIIN, INO 0810.03.1734 0 0 J z 0 z W z z 0 U 00 z MPROVEMENTS 0 W 2 cnW W 0 z u_ W co AIP NUMBER 5 -53 -0058 -043 z 0 I-- z C!) W DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1734