HomeMy WebLinkAboutPermit D11-224 - HATTON RESIDENCE - UPGRADESHATTON RESIDENCE
3935 S 113 ST
EXPIRED 03 -12 -12
Dl 1 -224
City �ukwila
S
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3351400105
Address: 3935 S 113 ST TUKW
Suite No:
Project Name: HATTON RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -224
Issue Date: 09/14/2011
Permit Expires On: 03/12/2012
Owner:
Name: HATTON RALPH L
Address: 3935 S 113TH , SEATTLE WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI919OA
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $29,458.00 Fees Collected: $1,092.10
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D11 -224 Printed: 09 -14 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant: N Number: 0
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
Size (Inches): 0
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complied
N
Private: Public:
Profit: N Non - Profit: N
Private: Public:
II Ii'' Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not pre
construction or the performance of
to this permit.
Signature:
to give authority to violate or cancel the provisions of any other state or local laws regulating
. I am authorized to sign and obtain this development permit and agree to the conditions attached
Date: WO (i)
Print Name: -3-6...4c 4 )%(1 -/=
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11 -224 Printed: 09 -14 -2011
this reauireinnt.
•
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -224 Printed: 09 -14 -2011
CITY OF TUKWILA)
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.wa.us
Building Permit°. blt, 1Z-
Mechanical Permit No
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 3935 S. 113th St.
Tenant Name: Ralph L. Hatton
Property Owners Name: Ralph L. Hatton
Mailing Address: 3935 S. 113th St.
King Co Assessor's Tax No.: 3351400105
Suite Number: Floor:
New Tenant: ❑ Yes ®..No
Seattle
WA
98168
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION =
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
E -Mail Address:
H: Applications\Porms- Applications On Line\2009 Applications \1 -2009 - Pe,mit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFOR 'i ION — 206 - 431 -3670
0
Valuation of Project (contractor's bid price): $ 29,458 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If ' yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H :'Applications \Forms- Applications Ooline\2009 Applications4-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1' Floor
1,022
2nd Floor
3rd Floor
Floors thru
Basement
250
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If ' yes', attach list of materials and storage locations on a separate 8-1/2" x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H :'Applications \Forms- Applications Ooline\2009 Applications4-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
PLUMBING AND GAS PIPIN(.ERMIT INFORMATION — 206 -437
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Intl Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
•
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR _ • ' ED AGENT:
Signature:
Date:
Print Name: othy J. Fen : s• , SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777
Mailing Address: 4000 Delri. ,e Way SW, Suite 200 Seattle WA 98106
City
State
Zip
Date Application Accepted:
(
Date Application Expires:
1
(,
Staff Initials:
H:'Applications •.Forms - Applications On Line,2009 Applications \1-2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
CitlOof Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: htiv. //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011
RECEIPT NO: R11 -01600
Initials: WER
Payment Date: 07/28/2011
User ID: 1655 Total Payment: 13,064.48
Payee: PAMELA K KUEHL
SET ID: 071911 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D11 -222 748.15
D11 -223 716.64
D11 -224 1,092.10
D11 -225 993.76
D11 -226 622.10
D11 -227 653.61
D11 -228 1,067.51
D11 -229 685.13
D11 -230 685.13
D11 -231 716.64
D11 -232 1,018.34
D11 -233 559.07
D11 -234 811.18
D11 -235 1,042.93
D11 -236 1,652.19
TOTAL: —/487t5--
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 13,064.48
TOTAL: 13,064.48
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 7,876.95
000.345.830 5,120.03
640.237.114 67.50
TOTAL: 13,064.48
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D11 -224
HATTON RESIDENCE
3935 S 113 ST TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 03/12/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fer Marshall
it Technician
File: Permit File No. D11 -224
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
PE
a C��
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -224
PROJECT NAME: HATTON RESIDENCE
SITE ADDRESS: 3935 S 113 ST
X Original Plan Submittal
Response to Correction Letter #
DATE: 07 -19 -11
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
i ` 'vision ` l
ul ding Ilvlsion ��
Pub 'v IPA tn.7'
Pb is or
A-
ire Prevention
Structural
P ming Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete n Incomplete ❑
DUE DATE: 07-21-11
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route n Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
Approved with Conditions
DUE DATE: 08-18-11
Not Approved (attach comments)
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
1
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCC19190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135245
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Landmark American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.0003
/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
ectrical
numbing
as Pip#ng
City of Tukwila
Rol DING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
'777: ro visions will require a new plan submittal
crdd may include additional plan review fees.
FI COPY Li
Permit No., .1 �" 2ZI
Pun revi3w approval is subject to errors and omissions.
kp :. ;roval of construction documents does not authorize
th violation of any adopted code or ordinance. Receipt
os approved Fiel edged:
City Of Tukwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
A-7-
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
,JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
International Mechanical Code
3351400105
ZONING: 5F1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Charge)
Y B NON SPRINKLERED
LEGAL DESCRIPTION:
HILLMANS C D MEADOW GARDENS* 3 TGW POR VAC 40TH AVE 5 ADJ
DUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
MAR ,1 22012
DRAWING INDEX
Told
AI.O
A2.0
A2.1
422
423
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
MI.0 LEGENDS, SCHEDULES, ABBRI=v., GENERAL NOTES 4 DWG INDEX
M20 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
E1.0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 95108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: SharynParkerekingcounty. ov
ARCHITECT:
S.M. Stemper Architects PLL.C.
4000 Delrldge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryeametemper.com
melody esmstemper.com
tlmesmstemper.com
ACOUSTICAL ENGINEER
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. S39. 0S19
Fax: 206. ass. 0824
Contact: Mohamed Alt Allaoua Contact: Brent Rollin
E -mail: mohamedessaacousticscom E -mail: bcretreswest.com
ELECTRICAL ENINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 58409
Ph: 253. 412. 3300
Fax: 253.412.3463
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98119
Ph: 206.31S. 0569
Fax: 206.318.0641
Contact: Chris Agar
E -mail: ChrlsAegreenbuschcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4100
Contact: Tim Ogden
E -mail: tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. ii200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwelleJonespayne.com
VICINITY MAP (NTS)
D1
214
ECEIVED
JUL 19 2011
PL {'. f.TO LATER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (206) 624 -2873
REGISTERED.
scoTT 1 TEMPE
STATE OF 11 1- NGTON
0810.03.1734
2/24/11
MPROVEMENTS
KING COUNTY
AIP NUMBER
5- 53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1734
STORAGE
FUR
'
LL
FAMILY
ROOM
BASEMENT PLAN
1/4" = 1'
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT I5 PRESENT AT TI-115 RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
KITCHEN
NORTH
BATH
LIVING
ROOM
- 18" x 1S" EXIST.
ATTIC ACCESS
PANEL
A
PRI 0 R TO COMMENCING WITH
DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OuNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK„ PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECT.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POUER OUTAGE IS EIGHT HOGS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. 4 AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WI -IERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
1-
N
O
0
C
ET
!BEDROOM
BEDROOM
2
MAIN FLOOR PLAN
1/4" = 1'
o<
12' -1"
21' -3"
cfl
r
TYF'.
r
J
1 1 • I.
r
. . . _ . . . _ . . . . J NEU12j " x 24 "- . .
ATTI ACCESS
V 11
I = =
`.18 ".x 18" EXIST.1
. ATTIC ACCESS!
- PANEL
_JI I11
C� ru
NN
NIN N
N
r1
I I
r l
r I
/
Cr /1
II 1
II 1
u I
1
r
L
I
n \\ 1
I -I
L- - - -1
1 �� L E.-- ..
- 7iki=TT-T-T1 R - -�1
. r , I 4 I - - I - I I - II - I -1 1 1, I- I . I-
/I� 1I H - - • /1 I• II. I- I - I -I - I -I -I - -
- -/. -1 -�`- - -1.1 - . . . - - - - 11- - - /I- 1.1.11.1 -I i F I- I-1- - -1
I 1- - - - - - - -- y
-\ I
r A/
CC 1 r 1 1
/___I
7 r- ---Li
r L-- _ -ft
T.
ATTIC PLAN
1 /4" = 1'
A. WEST ELEVATION
B. NORTH ELEVATION
PLAN KEYNOTES
EDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
ODEMOLISH EXISTING DOOMS), FRAME, CASING, AND THRESHOLD. INSTA -L NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR PETAL. COORDINATE WITH
MECHANICAL.
G:: INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER.
OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES.
OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/A22 FOR DETAIL.
0 ADDITIONAL SUPPORT AT BAY WINDOW REQUIRED REF. DETAIL 5/422 FOR DETAIL.
OSURPLUS (E) DOOR HARDWARE PER HOMEOWNERS REQUEST.
OAT (E) BAY WINDOW AREA, INSTALL 2X WOOD FRAMING AT ROUGH OPENINGS TO SUPPORT INSTALLATION OF NEW WINDOWS.
REF. 1/A22 FOR STRUCTURAL SUPPORT DETAIL BELOW SILL.
pl.,,,.., 21.
ACCESS TO SITE AND PARKING
I ,, r ,
.1
l
BEDROOM
2
MAIN FLOOR PLAN
1/4" = 1'
o<
12' -1"
21' -3"
cfl
r
TYF'.
r
J
1 1 • I.
r
. . . _ . . . _ . . . . J NEU12j " x 24 "- . .
ATTI ACCESS
V 11
I = =
`.18 ".x 18" EXIST.1
. ATTIC ACCESS!
- PANEL
_JI I11
C� ru
NN
NIN N
N
r1
I I
r l
r I
/
Cr /1
II 1
II 1
u I
1
r
L
I
n \\ 1
I -I
L- - - -1
1 �� L E.-- ..
- 7iki=TT-T-T1 R - -�1
. r , I 4 I - - I - I I - II - I -1 1 1, I- I . I-
/I� 1I H - - • /1 I• II. I- I - I -I - I -I -I - -
- -/. -1 -�`- - -1.1 - . . . - - - - 11- - - /I- 1.1.11.1 -I i F I- I-1- - -1
I 1- - - - - - - -- y
-\ I
r A/
CC 1 r 1 1
/___I
7 r- ---Li
r L-- _ -ft
T.
ATTIC PLAN
1 /4" = 1'
A. WEST ELEVATION
B. NORTH ELEVATION
PLAN KEYNOTES
EDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
ODEMOLISH EXISTING DOOMS), FRAME, CASING, AND THRESHOLD. INSTA -L NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR PETAL. COORDINATE WITH
MECHANICAL.
G:: INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER.
OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES.
OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/A22 FOR DETAIL.
0 ADDITIONAL SUPPORT AT BAY WINDOW REQUIRED REF. DETAIL 5/422 FOR DETAIL.
OSURPLUS (E) DOOR HARDWARE PER HOMEOWNERS REQUEST.
OAT (E) BAY WINDOW AREA, INSTALL 2X WOOD FRAMING AT ROUGH OPENINGS TO SUPPORT INSTALLATION OF NEW WINDOWS.
REF. 1/A22 FOR STRUCTURAL SUPPORT DETAIL BELOW SILL.
pl.,,,.., 21.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. EAST ELEVATION
1-
l
r
N
MAR 1 : 22012
1
D. SOUTH ELEVATION
LEGEND
ACOUSTICAL WINDOW
E[Y
T
NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. 42.0
SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
EXISTING KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
NOT USED
NOT USED
ATTIC INSULATION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISIOF,:
RECEIVED
JUL 19 2011
PE +,TC CENTER
AS
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
Qg GAS METER
I�!�I
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
A;'HITECT
COTT 1
STATE OF
0810.03.1734
TEMP
SHINGTON •
2/24/11
0
LL
ct
-J
ct
T
O
z
W
1-
z
KING COUNTY
AIP NUMBER
MPROVEMENTS
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1734
WINDOW TYPES
SINGLE HUNG
2
FIXED
3
SLIDER
4
SLIDER / SLIDER / FIXED
SLIDER / FIXED / SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
KITCHEN
2
4' -0" x 4' -5"
PAINT/PAINT
SAFETY GLAZING
1/42.0
B
KITCHEN
5
9' -I0" x 4' -5"
PAINT/PAINT
I/42.0
C
KITCHEN
3
5' -0" x 2' -I0"
PAINT/PAINT
I/42.0
D
LIVING ROOM
3
5' -3" x 4' -3"
PAINT/PAINT
1/420
E
LIVING ROOM
1
2' -4" x 4' -10"
PAINT/PAINT
SAFETY GLAZING
3 /A2.0
F
LIVING ROOM
2
5' -2" x 4' -10"
PAINT/PAINT
SAFETY GLAZING
3/42.0
G
LIVING ROOM
I
2' -4" x 4' -10"
PAINT/PAINT
SAFETY GLAZING
3/42.0
H
BEDROOM 1
3
4' -I0" x 4' -0"
PAINT/PAINT
Y
I /42.0
I
BEDROOM 1
3
4' -1" x 4' -3"
PAINT/PAINT
I /42.0
J
BEDROOM 2
3
4' -l" x 4' -3"
PAINT/PAINT
Y
I /A2.0
K
FAMILY ROOM
4
10' -1" x 2' -10"
PAINT/PAINT
SLIDER TO MATCH WINDOW "I"
2/42.0
L
FAMILY ROOM
3
4' -10" x 2' -10"
PAINT/PAINT
2/42.0
M
FAMILY ROOM
3
3' -10" x 2' -10"
PAINT/PAINT
2/42.0
(E) • EXISTING
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
REF. PHOTO 5/A22 FOR EXISTING CONDITION
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE CF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RA.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, COOL
FLUSH, AND PAINT FASTENER HEADS
AND MY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
WINDOW HEAD
tuD. JAMB LINING
SEALANT
51-11M AS NECESSARY
FILL GAP W/ BATT
INSULATION
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN -- .
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
WINDOW JAMB
(E) GU.
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM ,4S NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3/8"
3/4" WD. SILL - STAIN TO
MATCH (E)
WINDOW SILL
WOOD TRIM TO MATCI4
(E), PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GOB
WOOD SIDING - WINDOW DETAIL SET
3" = 1' - 0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL
UNDERLAYMENT AND INSTALL TOP
EDGE OF SELF - ADHERING MEMBRANE
AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TIP AT
HEAD AND JAMB
ti
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT 70 MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
(E) WALL UNDERLAYMENT
(E) WD. PANELING
(E) EXTERIOR SHEATHING
SELF ADHERING MEMBRANE
CAREFULLY CUT SACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING, INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER LEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) IUD. SIDING
WINDOW HEAD
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
WINDOW JAMB
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E) TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
(E) WD. PANELING
WOOD TRIM TO MATCH
(E), PAINT/STAIN TO
MATGH (E) TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
LI
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING AS
REQ'D FOR INSTALLATION OF
WINDOW ASSEMBLY AND TRIM.
REPLACE W/ NEW SIDING AS
REQ'D t0 MAINTAIN COURSING.
PAINT TO MATCH (E) SIDING
(E) EXTERIOR 514EATHING
(E) WD. SIDING
WINDOW SILL
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
(E) WD. PANELING
SELF - ADHERING
MEMBRANE
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0"
EXIST. SIDING
(E) BAY CONSTRUCTION
WINDOW NAIL FIN, TYPICAL
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND
PAINT TO MATCH (E)
TRIM. COLOR TO BE
FIELD DETERMINED
BACKER ROD 4 SEALANT
SELF- ADHERING MEMBRANE
ACOUSTICAL WINDOW
ASSEMBLY
CUT (E) WOOD PANELING AS
REQ'D TO INSTALL WINDOW
ASSEMBLY. REPLACE AND
MATCH (E) PANELING WHERE
DAMAGED DURING CONSTR,
TYPICAL.
s hOttitttl■ A
f:.
CUT (E) WOOD PANELING AS
REQ'D TO INSTALL WINDOW
ASSEMBLY. REPLACE AND
MATCH (E) PANELING WHERE
DAMAGED DURING
CONSTRUCTION, TYPICAL
SEALANT
III -2-21
(2) LAYERS OF SELF- ADI- IERING
MEMBRANE, TYPICAL
BACKER ROD 4 SEALANT, TYPICAL
ACOUSTICAL WINDOW ASSEMBLY
- WINDOW NAIL FIN, TYPICAL
.DOW
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT, TYPICAL
HARDWOOD TRIM TO MATCH
(E), PAINT/STAIN TO MATCH
(E) TRIM
(E) GWB SILL AT BAY WINDOW
ACOUSTICAL WINDOW
ASSEMBLY
CAREFULLY REMOVE (E) SIDING FOR
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING AS
REQ'D TO MAINTAIN PANEL PATTERN 4
PAINT TO MATCH (E) SIDING, TYPICAL
WINDOW JAMB
HARDWOOD TRIM TO MATCI4
(E), PAINT /STAIN TO MATCH
(E) TRIM
SELF- ADHERING MEMBRANE
BACKER ROD 1 SEALANT
WINDOW NAIL FIN
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND PAINT
TO MATCH (E) TRIM. COLOR
TO 5E FIELD DETERMINED
BACKER ROD 4 SEALANT
WINDOW SILL
CUT (E) WOOD PANELING
AS REQ'D TO INSTALL
WINDOW ASSEMBLY.
REPLACE AND MATCH (E)
PANELING WHERE
DAMAGED DURING CONSTR,
TYPICAL
WOOD SIDING - BAY WINDOW DETAIL SET
3" = 1' - 0"
E pi
MAR 1 Z2012
REVIEWED ED
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVE[
JUL 19 2011
PERMITCENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
4220
REGISTERED
A; HITE:cT
,1111" °fir
CUTT
STATE OF
0810.03.1734
2/24/11
TE MPE
WINGTON
0
d.
ce
J
z
0
z
w
1-
0
U
MPROVEMENTS
0
cw
w
w
0
z
LL
U
1-
0
w
ce
AIP NUMBER
5 -53- 0058 -043
0
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1734
DOOR TYPES
O
A
FLUSH SCW
W/ OBSERVATION
PORT
SECONDARY SLIDING
GLASS DOOR
W/ SAFETY GLAZING
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
KITCHEN
A
2' -8" x 6'4"
STAIN /SLAIN
I•IW -I 1 609
DK -4 (Camelot)
LOCK -1
I /A2.1
2
LIVING
B
I' -11" x 6' -8"
2/A2.1
3
FAMILY ROOM
A
4' -0" x 6' -3"
STAIN/STAIN
1 -NU) -1 / 609
DK -4 (Camelot)
LOCK -1
3 /42.1
4
KITCHEN
c
2' -S" x 6' -8"
1/A2.1
5
FAMILY ROOM
C
4' -0" x 6' -3"
3/A2.1
TYPICAL DOOR SCHEDULE NOTES
I. NOTE: WHEN SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED
N SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH TI4E OPERATION OF tHE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REM)
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STOp1 DOOR PER SCHEDULE
2" MIN.
SELF- ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
DOOR HEAD
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RA. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
.T
I \�11,
--; pzAis
Fi— ►" MI.
DOOR JAMB
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FLOOR STRUCTURE
DOOR SILL
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
(E) WD. SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
OVER SELF - ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
SELF- ADI- IERING MEMBRANE. TURN DOWN
OVER FRONT EDGE OF TRIM. ENSURE
NO MEMBRANE IS VISIBLE BELOW
FLASHING EDGE
2X CANTED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION OF FLASHING AND DOOR
HEAD ASSEMBLY
TRIM- PAINT TO MATCH (E) TRIM
CONTINUOUS 2x SOLID BLOCKING
AROUND PERIMETER OF DOOR FRAME.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) BLDG. PAPER
BACKER ROD AND SEALANT
SELF- ADI4EARING MEMBRANE
TRIM- PAINT TO MATCH (E) TRIM
DOOR HEAD
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF - ADHERING MEMBRANE
REMOVE (E) WOOD SIDING AND
REPLACE AS REQ'D. CAREFULLY LIFT
(E) WALL UNDERLAYMENT MD
INSTALL TOP EDGE OF
SELF- ADHERING MEMBRANE AGAINST
SHEATHING. EXTEND SELF - ADHERING
MEMBRANE 4" UP WALL FROM TOP OF
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP. AT
I4EA0 AND JAMB
(E) PRIMARY SLIDING DOOR
ASSEMBLY.
PRE- PRIMED GALV. FRY REVEAL TRIM
CONTINUOUS 2x SOLID BLOCKING AROUN
PERIMETER OF DOOR FRAME. PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
SELF- ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
WD. TRIM BEYOND
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
SEALANT
EXISTING GRADE OR SUBSTRATE
i" MIN. BETWEEN PRIMART
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
(E) BEVELED WD. SIDING
(E) EXTERIOR SHEATHING
LIFT (E) WALL UNDERLAYMENT.
LAP NEW UNDERLAYMENT UNDER
(E) UNDERLAYMENT 2" AND
CONTINUE OVER SLIDING GLASS
DOOR FRAME
(E) PRIMARY SLIDING
GLASS DOOR
(E) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAB.
OR (E) WD. FLOOR FRAMING
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
3" = 1' -0"
(E) WD. BIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF-ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
SELF- ADl- 4ERING
MEMBRANE
(E) EXTERIOR SHEATHING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO R.O. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
J
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEAT14ER- STRIPPING
DOOR JAMB
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR 6140E
2" MIN,
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
(E) EXTERIOR SHEATHING
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
FAINT/STAIN TO MATCH (E)
TRIM
514IM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR SILL
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 " =1' -0"
MAR 1 2 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City Of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
COTT ` W'T.EM4PE.
:STATE .,HINGTON
0810.03.1734
2/24/11
0
J
0
Z
W
z
z
0
0
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1734
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF - ADHERING
MEMBRANE. TYP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE- PRIMED, GALV. SHEET METAL
FLASHING W/ F.F. END CAPS UNDER
SELF- ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
11
11
SINGLE -FRAME WINDOW
ASSEMBLY.
(E) WALL UNDERLAYMENT
SELF ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 =1 -0
PIVOT HINGE
CAULKING ADHESIVE
INSTALL 2X BLOCKING
AROUND OPENING AND
FASTEN EDGES OF
DRYWALL TO BLOCKING.
ASSUME (E) CEILING
JOISTS 0 24" O.C. EXTEND
BLOCKING TO (E) CEILING
JOISTS (TYP)
(E) GWB
SNAP FRICTION CATCH
REMOVABLE DOOR
PAINT DOOR AND FRAME
TO MATCH (E) COLOR OF
CEILING
ATTIC ACCESS HATCH DETAIL
3 " =1' -0"
BACKER ROD 4 SEALANT
SELF - ADHERING MEMBRANE
CUT (E) WOOD PANELING
AS REQ'D TO INSTALL
WINDOW ASSEMBLY.
REPLACE AND MATCH (E)
PANELING WHERE
DAMAGED DURING CONSTR,
TYPICAL
WINDOW NAILING FIN
BAY TRIM- DIME ALL SIDES
AND PAINT TO MATCH (E) TRIM.
ALLOW 1/2" CLEARANCE TO
WINDOW FRAME FOR SEALANT
JOINT
METAL BRACKET±
MIN. (2) PER BAY
APRON TO MATCH
EXIST. SIDING
2X WOOD LEDGER±
INSTALL BLOCKING AT
EXIST. WALL FOR
ADDITIONAL SUPPORT
BACKER ROD ANS SEALANT
EXIST. SIDING
BAY WINDOW STRUCTURE DETAIL
3 " =1' -0"
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
INSULATION DAM DETAIL
3 " =1' -0"
INSULATION
INSULATION DAM
(E) WALL FRAMING
TRIM PHOTO DETAIL
NTS
EXISTING
CEILING
STRUCTURE
FINISH TO MATCH (E) PAINT AND
TEXTURE
SELF - ADHERING
MEMBRANE TO
WRAP ENTIRE
CORNER POST
ACOUSTICAL
WINDOW ASSEMBLY
X
Ix
ATTACH 2x3 LEDGER TO EXIST. DECK
ATTACH SOFFIT FRAMING TO LEDGER
DUCTS PER PLAN WITHIN SOFFIT
RE: MECHANICAL
2x2 CONT. NAILER
5le" GM- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR
/ TERMINATE EDGE W/ AD.)
ARCHITECTURAL FEATURES PER PLAN.
COORDINATE SOFFIT DIMENSIONS WITH
MECHANICAL
DUCT SOFFIT DETAIL
1 -1/2" = 1' - 0"
(E) WD FRAME WALL ASSEMBLY
CORNER POST DETAIL
VINYL COVER TRIM
TO MATCH WINDOW
ASSEMBLY UNIT
CONTINUOUS SEALANT AT
PERIMETER OF WINDOW FRAME
NEW SOLID P.T. BLOCKING (2)
SIDES AROUND PIPE COLUMN.
ATTACH W/ 1/4 -20 COUNTER-
SUNK SCREWS W/ WASHERS
IN DRILLED AND TAPPED
HOLES a 24" 0.C, TYP.
INSULATION
(E) PIPE COLUMN
IUD. TRIM. FINISH
TO MATCH EXIST.
SEALANT AND
BACKER ROD, TYP.
3 " =1' -0"
MAR 1 22012
tilt
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of TulzwilE
BUILDING DIVISION
ECEIVED
JUL 19 2011
TC NTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 90106
(208) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A . HITECT
0810.03.1734
2/24/11
z
W
W
Q Q
ct
>,—
4tC W
O E
®C �
Z
Lt
W 0
Z
Ct
Z F
o
0 <
0 —I
Z Q
W
0
W
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1734
0
0
0
0
0
0
0
0
0 •
0
0
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
XX
OR X.
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X/Y X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
$G -X
xxX
ABBR
-ads
4-F-
0
M
CD 0 R
EQUIP
NG
ICI
•
D'Q
DN
UP
VD
RA /EA
RG
SA
SA
RA /EA
SD
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
407
<.08 "WG
9 "4
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
180
407
<.08 "WG
9 "4
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1734
1721
2
180 CFM
180 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
174 v-1-1
EX
ED
MAR 1 22012
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) Oa
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION l/
QF = 60 / (1 X 1/3) = 180 CFM
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(206) 624 -2777 • FAX (206) 624 -2273
THE GREENBUSCH GROUP, INC
■■■• • •■•■ • • • e )
140091106.1113T AUDIO_[ vow t YEOFNNOAL UlOIEEiNR
190 N41®®wl
SEW SUITE 901 SOUns. it 01110
(106) 371 -0669 (206) 378 -0641 FAX
0810.03.1734
1—
rx
0
ce
J
z
O_
z
ce
w
F-
z
F-
z
0
z
U)
w
w
0
0
!>-
0
cnCw
w
w
0
Li-
z
0
AIP NUMBER
5 -53 -0058 -043
0
GO
0
z
I-
Q
CO
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1734
BEAM
ROUTE DUCT IN
SOFFIT AND 'TIGHT
TO JOISTS
STORAGE
ROUTE DUCT
)OWN TO
POC
ROUTE
UNDER BEAM
W
SOFFI T
BY OTHERS
ROUTE
DUCT IN
JOISTS `
JOIST\
J
o)
CORE DRILL
/CONCRETE
, --C
180
UP
(E)SG STORAGE
BASEMENT MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
CEILING
NORTH
SEE
CRAWLSPACE
CRAWLSPACE
ACCESS
ROUTE DUCT
DOWN AND
TIGHT TO WALL
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
z
w
w
0
cL
cn
w
FURNACE
OUTSIDE AIR TO FURNACE ELEVATION
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
SCALE: NONE
(E)SG
KI TCI —TEN
(E)SG
z (E)EG
LIVING
ROOM
(E)SG
(E)SG
CLOSET
(E)SG
BEDROOM
N
BEDROOM
2
O
U
(E)SG
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NORTH
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP CONNECTION DETAIL
SCALE: NONE
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY — CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
121\ 2.2-41
EXHi'ED
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
MAR 1 22012
RECEIVED
JUL 19 2011
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(208) 024 -2777 • FAX (zae) e24 -273
THE GREENBUSCH GROUP, INC
)))
AODlsacw. VIDEO a YEOINNOI. ENOINEE1910
1100 11ef Sheer BUIE 201 9212114 1A ISI1
(208) 37s -09ee Nolo 378 -0941 FAX
0810.03.1734
KING COUNTY INTERNATIONAL AIRPORT
z
Li!
W
0
ce
0
2
>-
W
Li]
W
0
O
z
LL
J
W
d
W
AIP NUMBER
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, MM & JA
BASEMENT
AND MAIN
FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1734
15/1
/"1 BLACK
L -0 0
N WHITE
PANEL
MP
LOCATION:
SERVING:
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
DESCRIPTION
RESIDENCE
AIC,
200
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
16
15
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE AP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
5
EXIST CKT
EXIST CKT
X
30/2
20
A
A
30/2
B
16
1,2
-
EXIST CKT
EXIST CKT
2
4
6
7
X
— - —
15
O
B 20/2
X
EXIST CKT
8
9
11
13
15
17
19
EXIST CKT
EXIST CKT
EXIST CKT
EXIST CKT
EXIST CKT
15
15
15
20
I A
A
A
B 15
20
B 30/2
13 30/2
EXIST CKT
EXIST CKT
EXIST CKT
EXIST CKT
10
12
14
16
18
20
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
20
20
21
EXIST CKT
30
A
22
23
25
27
29
SPACE
SPACE
SPACE
SPACE
A
A
B " 1511
B
0.01
0
SMOKE DETECTORS
SPACE
SPACE
SPACE
24
26
28
30
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
0.01
0.01 KVA
0.04 AMP
COMPUTED LOAD
0.01
0.01 KVA
0.04 AMP
❑ ISOLATED GROUND BUS
❑ RAINTIGHT NEMA-3R ENCLOSURE
FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP
DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL
PANEL SKIRTS ❑ SURFACE
INTEGRAL TVSS ❑ FLUSH
■
]
❑
❑
REMARKS:
** PROVIDE BREAKER TO MATCH EXISTING
CUTLER HAMMER PANEL
MECI- ANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
TIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
BRANCH CIRCUIT HOME RUN
®D
X
EJ
X
1,2
-
THERMOSTAT
24
1
X
— - —
X
O
THERMOSTAT
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLACK BLACK
WHITE
RED
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
STORRAE
FUR
UP
STORAGE
BASEMENT PLAN
1/4" = 1'
ELECTRICAL LEGEND
8Yh18OL
DESCRIPTION
5`fh18•L
DE6CRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
in AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
I I I
I 1
4
DAMPER CONNECTION
❑'
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
S❑'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
®D
FIRE ALARM SMOKE DETECTOR 120V OPERATED
EJ
ELECTRICAL METER
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY.
TIMER OPERATED SWITCH
— - —
O
THERMOSTAT
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOUT1ON OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
O PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
O PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
0 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE BACK
BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 120Vac AND PROVIDE
COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL SEE GENERAL NOTES FOR CEILING PENETRATION REQUIREMENTS.
O HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL
PENETRATION WORK.
0 PROVIDE NEW 15/1 BREAKER IN PANEL AND 2#14 &G TYPE NMB CONDUCTOR FOR SMOKE DETECTORS TO MATCH EXISTING. SEE PANEL
SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY WALL PENETRATION WORK.
KITCHEN
t01RJAGE
D,4INPER
BATH
LIVING
ROOM
CLOSET
1-
LH
0
0
15EDfsooM
2
SCPARATE
P
MITAND
APPROVAL
MAIN FLOOR PLAITEQUIRRD
1/4" = 1'
MAR 1 22012
RECEIVED
JUL 19 2011
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
■N.INCNIIN, INO
0810.03.1734
0
0
J
z
0
z
W
z
z
0
U
00
z
MPROVEMENTS
0
W
2
cnW
W
0
z
u_
W
co
AIP NUMBER
5 -53 -0058 -043
z
0
I--
z
C!)
W
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1734