HomeMy WebLinkAboutPermit D11-227 - BAKER RESIDENCE - UPGRADESBAKER RESIDENCE
11658 42 AV S
EXPIRED 03 -12 -12
Di 1-227
Parcel No.:
' Address:
'Suite No:
Project Name:
City oPTukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
3347400180
11658 42 AV S TUKW
BAKER RESIDENCE
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D11 -227
09/14/2011
03/12/2012
Owner:
Name:
Address:
BAKER ROGER E
11662 42ND AVE S , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $15,390.00
Type of Fire Protection: NONE
Type of Construction: V -B
Electrical Service Provided by: SEATTLE CITY LIGHT
Fees Collected:
International Building Code Edition:
Occupancy per IBC:
$653.61
2009
0022
* *continued on next page **
doc: IBC -7/10
D11 -227 Printed: 09 -14 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
N
N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
Public:
Non - Profit: N
Public:
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pr
construction or the performance of work
to this permit.
Signature:
Print Name:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
• I am authorized to sign and obtain this development permit and agree to the conditions attached
F 44--
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date: Ofhi
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-227 Printed: 09 -14 -2011
this requirement.
• •
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -227 Printed: 09 -14 -2011
CITY OF TUKWIL•
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No. b \ .
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 11658 42nd Ave. S.
Tenant Name:
Roger E. Baker
Property Owners Name: Roger E. Baker
Mailing Address: 11658 42nd Ave. S.
King Co Assessor's Tax No.: 3347400180
Suite Number: Floor:
New Tenant: ❑ Yes ..No
Tukwila
WA
98168
City
State
Zip
CONTACT PERSON — who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
Zip
H:\Applications \Forms - Applications On Line\2009 Applications \t -2009 - Permit Application.doc
Revised: 1 -2009
bb
Page 1 of 6
BUILDING PERMIT INFORM/00N — 206 - 431 -3670
Valuation of Project (contractor's bid price): $ 15,390 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
.
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1s` Floor
975
2nd Floor
'
3`d Floor
Floors - thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:- 'Applications `.Forms - Applications On Line /009 Applications '\ I -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 2 of 6
PLUMBING AND GAS PIPIN(RMIT INFORMATION - 206 - 431.70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Intl Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\ Applications \Forms- Applications On-Line \2009 Applications \1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review -- Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AU
Print Name: Ti • by J. Fenlas•�, SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Signature:
AGENT:
Date:
City
State
Zip
Date Application Accepted:
-1"'
19
Date Application Expires:
I
1 q— P—
Staff Initials: ,�
/�I
H :',Applications\For ns- Applications On Line Applications■l -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
Ci f of Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: htty: //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011
RECEIPT NO: R11 -01600
Initials: WER
Payment Date: 07/28/2011
User ID: 1655 Total Payment: 13,064.48
Payee: PAMELA K KUEHL
SET ID: 071911 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D11 -222 748.15
D11 -223 716.64
D11 -224 1,092.10
D11 -225 993.76
D11 -226 622.10
D11 -227 653.61
D11 -228 1,067.51
D11 -229 685.13
D11 -230 685.13
D11 -231 716.64
D11 -232 1,018.34
D11 -233 559.07
D11 -234 811.18
D11 -235 1,042.93
D11 -236 1,652.19
TOTAL:
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 13,064.48
TOTAL: 13,064.48
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 7,876.95
000.345.830 5,120.03
640.237.114 67.50
TOTAL: 13,064.48
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D11 -227
BAKER RESIDENCE
1165842 AV STUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 03/12/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 03/12/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
ifer Marshall
it Technician
File: Permit File No. D11 -227
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
40
PLAN EVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -227
PROJECT NAME: BAKER RESIDENCE
SITE ADDRESS: 11658 42 AV S
X Original Plan Submittal
Response to Correction Letter # _
DATE: 07 -19 -11
Response to Incomplete Letter #
Revision # After Permit Issued
D PART ENTS: 8,1,..t
Budding Division
'l..,II
Ic Wor s
fmn Nor c().1
Fire Prevention
Structural
L: l
►CIA 01 12111
Planning Division
Permit Coordinator
1
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -21-11
Complete Incomplete ❑
Comments:
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route M Structural Review Required n No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 08-18-11
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pter Friendly Page • Page 1 of 1
General /Specialty Contractor
A business registered as a construction contractor with LEI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135245
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.00
03/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni /bbip /Print.aspx 09/14/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
e'chanical
ectrical
P tubing
as Piping
City of Tukwila
EItwl''r..` ING DIVISION
REVISIONS
NA changes shall be made to the scope
Of work without prior approval of
Tukwila Building Division.
NOTE; Revisions will require a new plan submittal
cnd may Include additional plan review fees.
FITME COPY
Permit No.
"7
Plan roview approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of appro ved Field ��= ;w�'�:. owledged:
Date: , c1 /4/ 1
City Of lbkwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 03 2011
4 —
w11--
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
international Fire Code,
international Mechanical Code
3341400180
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV 01
ZONING: SF 1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Change)
V B NON SPRINKLERED
DUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
MAR .1 '12012
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
410 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHEDULE 4 DETAILS
42.1 DOOR TYPES, SCHEDULE 4 DETAILS
422 MISCELLANEOUS DETAILS
A23 WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCI- IEDULES, ABBRi v., GENERAL NOTES 4 DWG INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
E1.0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharp Parker
E -mail: Sharyn.Parkere+kingcounty.gov
ARCHITECT:
S.M. Stemper Architects P.L.L.C.
4000 Oelridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624.2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyasmstemper.com
tlmeematemper.com
ACOUSTICAL ENGINEER
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0324
ELECTRICAL ENGINEER
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Mohamed Alt Allaoua Contact: Brent Rollins
E -mail: mohamed+ssaacousticscom E -mail: bcretreswest.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson Sty Suite 201
Seattle, WA 98119
Ph: 206.31a0569
Fax: 206.316.0641
Contact: Chris Ager
E -mail: C171sAegreenbuschcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.-162. 41S0
Contact: Tim Ogden
E-mail: tiro ogdenapbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. *200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornwell
E -mail: JCornwellf*Joneepakne.com
VICINITY MAP (NTS)
Nov,-
RECEIVED
JUL 19 2011
T UlllITER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (208) 824 -2973
4220
REGISTERED.
TERED
.
n ,y iTECT
,lhi►'
scOTr I TEMPE
Sr,arc OF Ski iNGTON
0810.03.1828
2/24/11
nC
0
dC
z
0
i-
<
w
z
z
0
0
0
z
U)
z
W
W
0
ce
0
>-
0
w
w
w
0
z
u_
0
W
0
AIP NUMBER
5- 53- 0058 -043
z
0
z
CJ)
5
I—
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1828
L_GAS I
J
PRIOR TO COMMENCING WITH
DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT 15 PRESENT At THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
tAIL
BASEMENT
i
BASEMENT PLAN
1/4" = 1'
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN TI-EM TO THEIR ORIGINAL LOCATIONS AT NE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL SE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5 :00 FM TO 8:00 411 EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO 8E REPLACED SHALL NOT SE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW i5 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM- CLEANED AT NE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
II. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY NE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AID FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMA"! POKIER OUTAGE 15 EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 A1'1. 4 AFTER 5:00 PM.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11 CONTRACTOR IS TO VERIFY CHAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT, JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: EFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WIN MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WNDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
is. EXISTING WINDOW COVERINGS MUST BE REINStALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
1
18" x 24" EXISt.
ATTIC ACCESS
PANEL
KITCI -EN
BATH
CLOSET
F- ---H
LIVING
ROOM
BEDROOM
2
CLOSET
BEDROOM
/
MAIN FLOOR PLAN
1/4" = 1'
10' -11"
1
TYP.
P^
Ir
r
r8 "x24 "E(IST.
ATTIC ACCESS
PANEL-
\
J \I . - . . . . . . . . - .\
1\
• • . • . . ▪ 1 -I \ . . . . . . . -I–/
I \
• i� .—.. .
\\ _ 11_ \\ / 1
-� __ - --I - - -'- /
h\>__ _- .1r- � _I 7/. _ C` - 1
/5E CURB
1-1E11-1T AT EXJST.
AITT(IC ACCESS
t rt4EL
/
/
/
/
/
/
I
r
/
/
/
-A-
/
/ /
/ /
/ 1
/ /
7 /
/ V
/
I j 1 � \ I
Its . . .0 = .7 . . .- ...- .....LL�� EI\
J
J L J L J L_
ATTIC PLAN
1/4" = 1'
4T -9°
PLAN KEYNOTES
EDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
�DEMOLISH EX'T'ERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
OINSTALL VENT BAFFLE(6) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 3/422 FOR PETAL.
OINSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL.
ODEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR
WITH TRIM PACKAGE BON ELEVATIONS, INCLUDE INTERIOR HARDWARE SET.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
LEGEND
5' -4"
1 ACOUSTICAL WINDOW
L
I NOT USED
EXTERIOR/ STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. 42.1
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
E
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
A. NORTH ELEVATION
B. EAST ELEVATION
C. SOUTH ELEVATION
D. WEST ELEVATION
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
VENT BAFFLE
11111 NOT USED
NOT USED
MAR 1 2 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
ATTIC INSULATION
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
!GAS
NOT USED
GAS METER
RECEIVED
g�q�{ JUL 19 2011
0 6�t~`d Tli TCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
4220
REGISTERED
A "HITE:CT
SCOTT
STATE OF
0810.03.1828
EMPE
SHINGTON •
2/24/11
Et
0
Et
a
—J
Z
0
F-
Q
Ct
z
w
z
z
0
0
Z
MPROVEMENTS
FT NOISE REMEDY
0
t�C
J
z
W
0
CJ)
ce
W
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1828
WINDOW TYPES
SLIDER
2
FIXED
3
SLIDER/ FIXED /SLIDER
/%
4
SINGLE HUNG
WINDOW SCHEDULE
WIND.
NO
-
-r-
3
SLIDER/ FIXED /SLIDER
/%
4
SINGLE HUNG
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
BEDROOM 1
1
5' -0" x 3' -0"
STAIN/PAINT
CUT SILL TO 40" AFF FOR EGRESS (E) HT 46"
I /A2.0
B
BEDROOM 2
I
5' -0" x 3' -0"
STAIN/PANT
CUT SILL TO 40" AFF FOR EGRESS (E) HT 46"
1 /42.0
C
KITCHEN
I
4' -0" x 4' -0"
STAIN/PAINT
1/42.0
D
KITCHEN
4
3' -0" x 3' -9"
STAIN/PANT
1 /A2.0
E
LIVING ROOM
3
5' -I0" x 3' -0"
STAIN/PANT
1 /A2.0
F
LIVING ROOM
2
1 -0" x 5' -0"
STAIN/PANT
SAFETY GLAZING REQUIRED
1 /A20
(E) • EXISTING
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING t PANT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO EE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHNG
SELF ADHERING
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
SEALANT
II II II FILL GAP W/ BATTY
INSULATION
WINDOW HEAD
r1
--(E) GWB
WINDOW JAMB
WINDOW NAILING FIN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WD SIDING FOR
INSTALLATION OF WINDOW ASSEMBLY
AND TRIM. REPLACE W/ NEW SIDING AS
RI=Q'D TO MAINTAIN COURSING 4 PAINT
TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
II
WINDOW SILL
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
SACKER ROD 4
SEALANT
3/8"
3/4" WD. SILL - STAN
TO MATCH (E)
(E) WD. JAMB LINING
SELF - ADHERING
MEMBRANE
(E) CERAMIC TILE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 "= 1' -0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
N SECTION OS800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
EX
MAR .1 22012
2.21
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624 -2777 • FAX (208) 624 -2973
REGISTERED
A;,,HITEICT
C•OTT
STATE OF
0810.03.1828
2/24/11
0
0
J
z
0
Q
z
w
z
0
0
0
z
MPROVEMENTS
CD
w
2
w
w
0
L.L.
0
J
0
U.!
Or!
AIP NUMBER
5 -53- 0058 -043
0
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1828
DOOR TYPES
Aft
O
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
� G
FLUSH SCW EXTERIOR
HALF -LITE W/ SINGLE LEAF STORM
2 PANELS W/ SAFETY GRILLE
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
ENTRY
A
2' -11" x 6' -6"
STAIN/STAIN
HW -I / 616
DK -2
LOCK -1
1/A2.1
2
KITCHEN (INTERIOR)
B
2'-l" x 6' -8"
STAIN/STAIN
14111-2 / 616
DK -5
N/A
2/A2.1
3
ENTRY
C
2' -11" x 6' -6"
STAIN/STAIN
I /A2.1
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHEN SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED
N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH NE OPERATION OF THE
EXISTING SLIDING GLA55 DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E) WD- SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP At HEAD
AND JAMS
REMOVE (E) Loop SIDING AS REQ'0
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STOW DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RO. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
DOOR HEAD
CONTINUOUS SEALANT BEHND
Z BAR FRAME
STORM DOOR PER SCHEDULE
SP!
�" MIN.
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTNUOUS WEATHER - STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
DOOR JAMB
SHIM AS NECESSARY
FILL GAP W/ BAIT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS U EATHER-
STRIPPING
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FLOOR STRUCTURE
DOOR SILL
WOOD SIDING - DOOR DETAIL SET
3 "= 1' -0"
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
2x CEILING FRAMING
CONNECTED TO UNDER
SIDE OF EXIST. TRUSS
FRAMING W/ ONE LAYER,
5/8" GUJB, TAPED,
FINISHED, PRIMED AND
PAINTED 2 COATS
WOOD BLOCKING
HARDWOOD TRIM TO MATCH
(E), PAINT /STAIN TO MATCH
(E) TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KERF IN CONTINUOUS
WEATHER STRIPPING
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
DOOR HEAD
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KEW IN CONTINUOUS
WEATHER STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR SHOE
DOOR JAMB
AUTOMATIC DOOR SWEEP
HARDWOOD TRIM TO
MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
INTERIOR DOOR PER
SCHEDULE
EXISTING FRAMING
HARDWOOD TRIM TO
MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
DOOR PER SCHEDULE
DOOR SILL
INTERIOR - DOOR DETAIL SET
3 " =1' -0"
EX *E
r;
MAR .1 22012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 1 9 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824 -2777 • FAX (208) 824 -2973
REGISTERED
A, HITE:CT
;'i/rl fi''`r
C01T
STATE OF
0810.03.1828
2/24/11
TEMPE;
HINGTON
0
0
ce
J
z
0
z
w
z
z
0
U
00
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1 828
(E) BACKER BOARD
(E) VINYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL. FLASHING AND EXTEND SELF
ADHERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDING AS REQ'D FOR
INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING,
ACCESSORIES, 4 BLOCKING TO MATCH (E).
PRE - PRIMED, GALV SHEET METAL ti -
UNDER SELF- ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REPLACEMENT SIDING AS REQUIRED
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
SHIM BACKER BOARD AS
REQUIRED
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
(E) EXTERIOR SHEATIING
2X2 BLOCKING, 4 SIDES
(PT.)
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
X11 -��'I
INSULATION DAM DETAIL
3 " =1' -0"
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
INSULATION
INSULATION DAM
(E) WALL FRAMING
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2"X SPACER
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW P' INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
RIDGE VENT BAFFLE DETAIL
1 1 /2" = 1' - 0"
EX , ED
MAR 1 2 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
P RMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • PAK (206) 824 -2973
4220
REGISTERED
A ,HITEICT
'COTT VTEMPE.
STATE OF ! ,SHINGTON •
0810.03.1828
2/24/11
0
0
ce
J
z
0
ce
w
1—
z
z
0
U
Ca
z
MPROVEMENTS
AIP NUMBER
5- 53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1828
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT 5140WN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
WAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 1 -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND 1 i"
BEYOND RO. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. A5
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
II" MIN
1/2" TYP.
C1.
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
Jr 5 1/
BUTTERFLY COtaNER FLASHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
8
0
0
0
0
0
0
0
0
0 0 0
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'R5 SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
1
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PRE ARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRI
(FOLLOW! STEPS).
L J
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
2
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
0
0
0
0
0
0
0
TYP.
l
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
r
C-5- MEMBRANE FLASHING AT SILL
} SCALE: NTS
INSTALL SHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW 1/8" CLEARANCE
BETWEEN FL • ING AND
80T. EDGE . (E)
SIDING.
TRIMMED EDGE
OF (E) SIDING,
SHOWN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
C-9-
HEAD FLASHING INSTALLATION
} SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
R.O. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
- INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
GENERAL NOTES:
1: MEMBRANE FLASHING 15 SPECIFIED N 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS SEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS SEEN INSTALLED.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
C10
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
0 0
WINDOW FLASHING INSTALLATION
SCALE: NTS
MAR .12 2012
evalanewomeynn
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
TGTEE h
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
0810.03.1828
TEMPE'
SHINGTON
2/24/11
1-
ce
0
a_
Z
0
z
w
z
z
O
0
z
MPROVEMENTS
>-
0
w
2
w
ce
w
CO
0
1—
u_
W
w
ce
AIP NUMBER
5 -53- 0058 -043
z
0
F-
0
LLI
Z
Cn
C/)
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1828
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPI CAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ASS
AC>
XX
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
UNE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT AND MAIN FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL A@E
5G -X
XXX
F-m-DNI DN
UP I + UP
f f
VD
RA /EA
RG
SA
SA
RA /EA
SD
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
® OR THERMOSTAT
EQUIP IDS EQUIPMENT LOCATION
ICI
MOD
NG NG
D
O
•
Db
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
344
C08 "WG
8 "93
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
120
344
C08 "WG
8 "93
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1828
1674
2
120 CFM
120 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
_
NOTES: - --
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
911-9..221
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
ft •
XPI ED
MAR 122012
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (BEGR X F)
QR = (FROM TABLE 403.8.1) Q.
&EGR = VENTILATION EFFEC11VENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 142.
QF = 60 / (1 X 1/2) = 120 CFM
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Comp.gy
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(eoe) 824 -8777 • P11 (20e) e24 -2078
THE GREENBUSCH GROUP, INC
1,00 r (IC1�19CN AIM i �,FIIQ 19
(208) 378 -0580 (206) 378-0041 FAX
0810.03.1828
i-
ct
0
0
J
z
0
I—
w
z
z
0
0)
w
w
0
ct
>-
0
w
2
w
cc
w
0
z
u_
AIP NUMBER
5 -53 -0058 -043
O
0
co
Z
W Q
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1828
GAS
METER
BASEMENT
1
a
BASEMENT MECHANICAL PLAN
SCALE: 1 = 1' —O"
CEILING
T
1 WC -1 SEE
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
FLOOR
FURNACE
120
NORTH
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
MOD, INTERLOCK
TO FURNACE
POC <1-
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
KITCHEN
J
BATH
CLOSET
(E)SG
(E)SG
BEDROOM
2
(E)SG
LIVING
ROOM
BEDROOM
(E)SG
(E)SG
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS. REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP CONNECTION DETAIL
SCALE: NONE
1
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10
FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE
HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY,
INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE
WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL
BE CAPABLE OF OPERATING THE VENTILATION SYSTEM
WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES).
COORDINATE FINAL TIME SETTING WITH PROJECT
REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51- 52- 0403.8.2 -5.8.
INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
EXH!ED
MAR 1 2.2012
RECEIVED
JUL 19 2011
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 06100
(206) 024 --2777 • FAX (206) 624 -2973
THE GREENBUSCH GROUP, INC
)))
i r 110elh MO IETWIISILN. ENOINEE 1110
1900 fBf SIT SITE 901 £ T1IE, IR 16119
(206) 378- 0009 (206) 378 -0941 FAX
0810.03.1828
w
w
(X O
ct
< w
O w
rt
eZ
w
Z
z �
o
�..� <
{,) -J
Z
w
C/)
w
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
BASEMENT
AND MAIN
FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1828
15/1
L —0 0
N
BLACK
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACIUTATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
04 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE
DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE
Arne.
BLACK
MECHANICAL i ELECTRICAL COOP 'NATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15
16
N/A
15
16
N/A
REMARKS
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
THERMOSTAT
24
1
x
x
X
1
REMARKS: 1 — VER FY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLACK
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
_F
a
ISASEMENT
1
TO Hi 14C
POWER SUPPLY
FUR
BASEMENT PLAN
1/4" = 1'
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SQL
DESCRIPTION
120 /240
VOLT,
1 PHASE, 3
WIRE.
BKR
UGHIING OR POWER PANEL
AIC,
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
I I I
I 1
DAMPER CONNECTION
❑'
NON —FUSED DISCONNECT SWITCH
o
MAST, WEA1HERHEAD
Q'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
CKT
BRANCH CIRCUIT HOME RUN
@
FIRE ALARM SMOKE DETECTOR 120V OPERATED
g
ELECTRICAL METER
®
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
i
2
4
6
8
TIMER OPERATED SWITCH
— — —
O
THERMOSTAT
PANEL
MP
LOCATION:
SERVING:
0810.03.1828
10,000
120 /240
VOLT,
1 PHASE, 3
WIRE.
BKR
RESIDENCE
AIC,
100
AMP with MAIN
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
5
7
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
30/2
20/1
20/1
A
A
B
B
50/2
1511
20/1
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
2
4
6
8
9
11
EXISTING LOAD
EXISTING LOAD
20/1
20/1
A
$
2011
20/1
EXISTING LOAD
EXISTING LOAD
10
12
13
15
17
19
21
23
EXISTING LOAD
SPACE
SPACE
SPACE
SPACE
SPACE
20/1
A
A
A
9
B
g
MI"
SMOKE DETECTORS
SPACE
SPACE
SPACE
SPACE
SPACE
14
16
18
20
22
24
PHASE LOAD PHASE A=
#VALUEI
KVA PHASE B=
KVA
LOAD TYPE
L
R
M
H
WH
0
A
K
LM
TOTAL LOADS
C ON N _ LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑ ISOLATED GROUND BUS FEED THRU LUG$ Q MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE
❑ RAINTIGHT NEMA -3R ENCLOSURE El DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL p INTEGRAL TVSS ❑ FLUSH
REMARKS: "* PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM.
KITCHEN
5ATN
CLOSET
i
MP /24
TO FURNACE
DAMPER
LIVINC1
ROOM
P EDROOM
2
BEDROOM
NORTH
17 1
MAIN FLOOR PLAN
1/4" = 1'
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
MAR 1 'Z2012
RECEIVED
JUL 19 2011
PER ITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (206) 624 -2973
ENOINNCIIN. INO
Mil OM 4•10 maw sum
wow ONSIMS
MMINIM MO OR WM
I$ NM 411 S
0810.03.1828
0
0
J
z
0
L.L.
w
1-
z
z
0
0
00
MPROVEMENTS
0
w
w
w
0
z
U
rt
J
w
AIP NUMBER
5 -53- 0058 -043
0
1—
(9
Lct
z
I-
Q
LLJ
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1 828