HomeMy WebLinkAboutPermit D11-228 - BAKER RESIDENCE - UPGRADESBAKER RESIDENCE
11662 42 AV S
EXPIRED 03 -12 -12
Dl 1 -228
Parcel No.:
Address:
Suite No:
Project Name:
City oftukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
3347400185
11662 42 AV S TUKW
BAKER RESIDENCE
DEVELOPMENT PERMIT
Permit Number:
Issue Date:
Permit Expires On:
D11 -228
09/14/2011
03/12/2012
Owner:
Name:
Address:
BAKER ROGER E
11662 42ND AVE S , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $28,890.00
Type of Fire Protection: NONE
Type of Construction: V -B
Electrical Service Provided by: SEATTLE CITY LIGHT
Fees Collected:
International Building Code Edition:
Occupancy per IBC:
$1,067.51
2009
0022
* *continued on next page **
doc: IBC -7/10
D11 -228 Printed: 09 -14 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
N
N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
r •
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
Date:
Public:
Non - Profit: N
Public:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not p
construction or the performance of work.
to this permit.
Signatur
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
Date: 7 /yhl
Print Name: --c-e4 6i: 4i9/1 -6-
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-228 Printed: 09 -14 -2011
this requirement.
III •
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -228 Printed: 09 -14 -2011
CITY OF TUKWILI.
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.citukwila.waus
Building Permit No. 9
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 3347400185
Site Address: 11662 42nd Ave. S.
Tenant Name: Roger E. Baker
Property Owners Name: Roger E. Baker
Suite Number: Floor:
New Tenant: ❑ Yes 0 ..No
Mailing Address: 11662 42nd Ave. S.
Tukwila
WA
98168
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:Wpplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORNt. .'ION 206- 431 -3670
Valuation of Project (contractor's bid price): $ 28,890 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1't Floor
975
2n° Floor
3rd Floor
Floors thru "
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application doc
Revised: 1-2009
bh
Page 2 of 6
PLUMBING AND GAS PIPINC ERMIT INFORMATION - 206 -431 7
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
not yet awarded
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:Wpplications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
PERMIT APPLICATION NOTES — Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUT 11/ ' / AGENT:
er Timo J. Fenlason Stemper Architects, PLLC
Signature.
Print Name:
Mailing Address: 4000 Delridge
ay SW, Suite 200
Date:
Day Telephone: (206) 624 -2777
Seattle WA 98106
City
State
Zip
Date Application Accepted: 1 � I t
I
Date Application Expires:
1--4 9-
Staff Initials:
r', II -
H:\Applications\Fonns- Applications On Line\2009 Applications \ 1-2009 -Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
Citbof Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwi' Washington 98188
Phone. .,6- 431 -3670
Fax: 206-431-3665
Web site: httn: //www.ci.tukwila.wa.us
SET RECEIPT
Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011
RECEIPT NO: R11 -01600
Initials: WER
Payment Date: 07/28/2011
User ID: 1655 Total Payment: 13,064.48
Payee: PAMELA K KUEHL
SET ID: 071911 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D11 -222 748.15
D11 -223 716.64
D11 -224 1,092.10
D11 -225 993.76
D11 -226 622.10
D11 -227 653.61
D11 -228 1,067.51
D11 -229 685.13
D11 -230 685.13
D11 -231 716.64
D11 -232 1,018.34
D11 -233 559.07
D11 -234 811.18
D11 -235 1,042.93
D11 -236 1,652.19
TOTAL: -/•= 8-15--
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 13,064.48
TOTAL: 13,064.48
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 7,876.95
000.345.830 5,120.03
640.237.114 67.50
TOTAL: 13,064.48
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D11 -228
BAKER RESIDENCE
11662 42 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 03/12/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fifer Marshall
it Technician
File: Permit File No. DI 1 -228
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
1 PE w.fi l COPY.
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -228
DATE: 07 -19 -11
PROJECT NAME: BAKER RESIDENCE
SITE ADDRESS: 11662 42 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
i ding 1i ision
T1 ti
N x Cr1,
Public Works
ire Pre eh on 1� II
Structural
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Incomplete ❑
Planning Division
Permit Coordinator
DUE DATE: 07 -21 -11
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
DUE DATE: 08-18 -11
Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
•
General /Specialty Contractor
A business registered as a construction contractor with LW to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135245
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011
KING COUNTY
NTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
lectrical
numbing
as Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOT : f svisians will require a new plan submittal
and may include additional plan review fees,
FILE COPY
Permit No.
8
Plan review approval Is subject to errors and omissions.
Ap:irova1 of construction documents does not authorize
t� ;• c' ,t an of any adopted code or ordinance. Receipt
a approved FiQlci.%.,.�* knowledgcd:
City Of l icwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, 1114
APPLICABLE CODES:
2009 International Residential Code,
international Fire Code,
international Mechanical Code
3341400185
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV • 1
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
22NStii1,lCTION TYPE: (No Change)
v B NON SPRINKLERED
DUiLDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
MAR .1 22012
DRAWING INDEX
T0.0
A1.0
A2.0
42.1
A22
A23
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBREv, GENERAL NOTES 4 DWG INDEX
M2.0 BASEMENT, MAN, AND UPPER FLOOR MECHANICAL PLANS AND DETAILS
E1.0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle 1114 98108
Pig 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stemper Architects P1.L.C.
4000 Perridga Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryeamstemper.com
melodyesmstemper.com
tlmesmstempercom
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua
ELECTRICAL ENGINEER
Tres Went Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 96.409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: mohamedessaacoustics.com E -mall: bcretreswest.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98119
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: aria Ager
E -mail: ChrlaAegreenbuschcom
REGULATED MATERIALS:
PBS Engineering and Environmental
2811 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph 206. 232. 9639
Fax: 206.162. 4180
Contact: Tim Ogden
E- mail:. tiro ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 4100
Boston, MA 02114
Contact: Tim Fenlaeon/ Jim Cornwell
E -mail: JCornwellejonespayns.com
VICINITY MAP (NTS)
RECEIVE
JUL 1/�9 2011
0 ,wni`v� iTCENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824 -2777 • FAX (20B) 624 -2973
4220
,m/Pr
SCOT. #
STATE;. OF
0810.03.1829
TEMPE
wi „NGTDNii
2/24/11
H
CL
0
CL
ct
Nt
7=t
z
0
ct
z
w
z
KING COUNTY
z
w
0
0
0
w
w
w
C/)
O
Z
w
0
LLl
AIP NUMBER
5- 53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1829
(E)
FAMILY
ROOM
BASEMENT
FLW
PRIOR TO COMMENCING WITH
DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
NW A
MO
S NT PLAN
1/4" = 1'
1-
0
0
NOTE:
1. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081.
BEDROOM
1
(E)
CLOSET
1—
w
d)
0
0
BATH
(E)
(
KITCHEN
LIVING
ROOM
(I)
0
DINING
ROOM
(E)
MAIN FLOOR PLAN
1/4" = 1'
NOTE:
INTERIOR TRIM TO BE FINISHED OAK
NOTE: SECURITY ALARM SYSTEM PRESENT. COORDINATE WITH HOMEOWNER
FOR TEMPORARY DISCONNECTION AND RECONNECTION OF THE SECURITY
SYSTEM PRIOR TO START OF WORK
GENERAL NOTES
I. CONTRACTOR TO PROTECT OU1 ERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
B. ALL WORK AREAS 514ALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
II. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET Alm FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
I. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POLIER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M.
I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECI- INICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY A5 COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
(
ATTIC
0
0
BEDROOM
3
V
r
1-
N
0
0
ATTIC
(E)
BEDROOM
2
ATTIC
UPPER FLOOR PLAN
1/4 "= 1'
26' -3"
61
N
I—
H
H
L_
__1/
\ /
\ /
\ /
\ i u
\ 1 11
�L 11
6' -2"
H
H
/
J
/
:– -.- -, -, - - -.- ^IF Z —_ —.—
4
/
r
FILJ
\ -1
1
ROOF PLAN
1/4" = 1'
L _
1// \ MAR •1 2'2012
A. WEST ELEVATION
C. EAST ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42,0
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, MD STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A2.2 FOR DETAIL. COORDINATE WITH
j MECHANICAL.
0 NSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
c INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER
OINSTALL FIREPLACE CAP .4T (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION INSTALL PER
MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES.
c:: INSTALL VENT BAFFLE(S) AT EXISTING RIDGE VENT(S) IN ATTIC, RIcF. 3/A22 FOR DETAIL.
O & DEMOLISH EXISTING DOOR(5), INSTALL NEW ATTIC ACCESS PANEL DOOR(S) REF. DOOR SCHEDULE ON SHEET A2.I. FLUSH SOLID CORE
INTERIOR WOOD DOOR
rq
t. tooll'` 90.mf.i.t
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND TI4EIR SUBCONTRACTORS SHALL NOT PARK OR B_OCK ACCESS TO HOMEOWNER DRIVEWAY.
B. NORTH ELEVATION
D. SOUTH ELEVATION
LEGEND
1 1 ACOUSTICAL WINDOW
NOT USED
EXTERIOR/ INTERIOR/ STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. 42.1
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
VENT BAFFLE
NOT USED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
ATTIC INSULATION PE`- `y +'TCE TER
SO INSTALL BATTERY OPERATED SMOKE
DETECTORS
NOT USED
AS GAS METER
w
S.M.STEMPER
ARCHITECTS
A Prateasional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A HITE:CT
0810.03.1829
2/24/11
Il
0
Ct
J
E
0
F'—
LL
w
F-
E
z
0
E
MPROVEMENTS
FT NOISE REMEDY
ct
J
z
w
0
(75
w
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1829
WINDOW TYPES
COTTAGE
2
FIXED
3
SLIDER
4
SINGLE HUNG
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
LIVING ROOM
2
1' -0 x 4' -5"
STAIN/PAINT
-
2/A2.0
B
LIVING ROOM
1
3' -0" x 4' -5"
STAIN/PAINT
2/42.0
C
BEDROOM I
2
3' -4" x 1' -9"
STAIN/PAINT
2/42.0
D
BEDROOM I
4
4' -0" x 4' -5"
STAIN/PAINT
y
2/A2.0
E
KITCHEN
4
3' -2" x 3' -6"
STAIN/PAINT
2/4.2.0
F
KITCHEN
4
3' -2" x 4' -2"
STAIN/PAINT
2/42.0
G
KITCHEN
4
2' -9" x 2' -6"
STAIN/PAINT
2/A2.0
14
DINING ROOM
2
1' -0" x 4' -5"
STAIN/PAINT
2 /A2.0
I
LIVING ROOM
2
2' -0" x 1' -9"
STAIN/PAINT
2/42.0
J
LIVING ROOM
2
2' -0" x 1' -9"
STAIN/PAINT
2/A2.0
K
LIVING ROOM
2
1' -0 x 4' -5"
STAIN/PAINT
SAFETY GLAZING REQUIRED
2/42.0
L
FAMILY ROOM
3
4' -0" x 11-6"
STAIN/PAINT
SAFETY GLAZING REQUIRED
3/42.0
M
FAMILY ROOM
3
4' -0" x 1' -6"
STAIN/PAINT
SAFETY GLAZING REQUIRED
3/4210
N
HALLWAY/ LANDING
3
4' -2" x 3' -V
STAIN/PAINT
SAFETY GLAZING REQUIRED
1/A2.0
0
BEDROOM 2
3
4' -2" x 3' -7"
STAIN/PAINT
SAFETY GLAZING REQUIRED
y
1/42.0
P
BEDROOM 3
3
4' -2" x 3' -7"
STAIN/PAINT
SAFETY GLAZING REQUIRED
Y
1/A2.0
Q
KITCHEN ENTRY
2
1' -6" x 3' -0"
STAIN/PAINT
SAFETY GLAZING REQUIRED
1/A2.0
(E) = EXISTING NOTE: ADD A 2X WOOD FRAME TO WINDOWS N, 0, AND P TO MAKE THE WIDTH 48"
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN TI.4AT
UNIT ARE TO 8E TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, 8UT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
War IfIf
EXISTING SOFFIT AND FRAME
SEALANT
VZLIZZLZGI
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
ACOUSTICAL WINDOW ASSEMBLY
r-
CAREFULLY GUT BACK (E) WD. SIDING
t0 ALLOW FOR REATTACHMENT t0 RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(,E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PANT FASTENER HEADS
AND ANY GRAMS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN
u
11
III I �
WINDOW HEAD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WD SIDING
L I II
WINDOW JAMB
IX WOOD LINER
WOOD TRIM TO
MATCH (E),
PAINT /STAIN TO
MATCH (E) TRIM
IUD. JAMB LINING.
FINISH TO MATCH (E)
SEALANT 4 BACKER
ROD
(E)GWB
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM A5 NECESSARY
FILL GAP W/ BATT
INSULATION
BACKER ROD 4
SEALANT
3 /8"
3/4" WD. SILL - STAIN TO
MATCH (E)
WINDOW SILL
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
�J
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E) GWB
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT /STAIN TO
MATCH (E) TRIM
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN -------`-
WINDOW HEAD
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) WP SIDING
II
WINDOW JAMB
(E) GWB
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP 111/ BATT
INSULATION
ICI
3/8"
3/4" WD. SILL - STAIN TO
wiloi �111 MATCH (E)
'411111c111 WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
BACKER ROD 4
SEALANT
WINDOW SILL
SELF- ADHERING
MEMBRANE
(E) GWB
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF- ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
(E) GUS
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WD. SIDING
TO ALLOW FOR REATTACHMENT TO RO.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PAINT FASTENER I4EADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
WINDOW HEAD
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT /STAIN TO
MATCH (E) TRIM
WD. JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
ACOUSTICAL WINDOW ASSEMBLY. USE
TAP -CON SCREWS FOR INSTALLATION
At (E) CMU WALL
n
r ICJ
11 11 I II I
WINDOW JAMB
(E) GWB
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
IUD JAMB LINING
SEALANT
SH111 AS NECESSARY
FILL GAP W/ BATT
INSULATION
EXPIRED
BACKER ROD AND SEALANT
2 "X8" PRESSURE TREATED WOOD
ii «1
i I r «<rii i i i �� A
MAR 1 2 2012
REVIEWED FOR
CODE COMPLIANC
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISIO
SEALANT 4 BACKER ROD
3/8" MIN.
/4" WOOD SILL PAINT /STAIN
TO MATCH (E)
TRIM- MATCH (E) TRIM. PRIME ALL SIDES
AND PAINT TO MATCH (E) TRIM. COLOR TO
BE FIELD DETERMINED
FLEX FLASHING
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF WINDOW ASSEMBLY AND
TRIM. REPLACE W/ NEW SIDING AS REQ'D TO
MAINTAIN COURSING. PAINT TO MATCH (E)
SIDING
(E) CONCRETE WALL
WINDOW SILL
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0„
GUS EDGE METAL
CUT (E) GWB AS REQUIRED.
PATCH TO MATCH (E)
TEXTURE AND PAINT FULL
EXTENT OF WALL TO MATCH
(E) WALL COLOR
TAPE AND FEATHER
MUD JOINT
RECEIVE
JUL 19 201
PERMITCENTI
D
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(206) 624 -2777 • PAX (208) 824 -2973
422,0
COTT
STATE OF
0810.03.1829
REGISTERED
Aa HITEICT
TEMPE
SHINGTON
2/24/11
ct
0
0
ce
—J
z
0
Q
z
W
z
z
0
U
(9
z
MPROVEMENTS
AIP NUMBER
5- 53- 0058 -043
z
0
0
z
co
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1829
DOOR TYPES
0
A
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
FLUSH SCW
HALF -LITE W/
2 PANELS
W/ SAFETY GLAZING
C
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GRILLE
FLUSH SCW
INTERIOR
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
3' -0" x 6' -S"
STAIN/STAIN
1-1W -1 / 612
DK -2
LOCK -1
I /A2J
2
KITCHEN ENTRY
B
2' -8" x 6' -8"
STAIN/STAIN
1-111J-1 / 612
DK -2
LOCK -1
1/A2.1
3
ENTRY
C
3' -0" x 6' -S"
STAIN/STAIN
1 /A2J
4
KITCHEN ENTRY
c
2' -S" x 6' -8"
STAIN/STAIN
1/A2J
5
HALL (attic access)
D
2' -0" x 4' -6"
STAIN/STAIN
HW -2 / 612
DK- 5(Access Door)
N/A
2/A2.1
6
EEDROOM 2 (attic access)
D
2' -0" x 4' -6"
STAIN/STAIN
HW -2 / 612
DK- 5(Access Door)
N/A
2 /A2.1
1
HALL (attic access)
D
2' -0" x 4' -6"
STAIN/STAIN
HW -2 / 612
DK- 5(Accees Door) N/A
2/A2.1
TYPICAL DOOR SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
1 TRIM. REPLACE W/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE MELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
ST0101 DOOR PER SCHEDULE
2" MIN.
SELF - ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO RA. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP N SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
DOOR HEAD
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
DOOR JAMB
51-11M AS NECESSARY
FILL GAP W/ GATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FRAMING
EXISTING FLOOR STRUCTURE
DOOR SILL
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
514IM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3 "= 1' -0"
CONTINUOUS WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KERF IN CONTINUOUS
WEATHER STRIPPING
WOOD BLOCKING
CONTINUOUS WOOD TRIM
WOOD FRAME
SURFACE APPLIED
CONTINUOUS WEATHER
STRIPPING
KERF IN CONTINUOUS
WEATI4ER STRIPPING
JAMB BEYOND
WOOD DOOR
PER SCHEDULE
DOOR HEAD
EXISTING FRAMING
DOOR JAMB
DOOR SILL
CONTINUOUS WOOD
TRIM
INTERIOR DOOR PER
SCHEDULE
EXISTING FRAMING
CONTINUOUS WOOD TRIM
DOOR PER SCHEDULE
ATTIC ACCESS - DOOR DETAIL SET
3 " =1' -0"
ill -J.2.1
EX
IRED
MAR 1 22012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
HITEICT
COTT V4TEM.PE''
STATE OE ! HINGTO
0810.03.1829
2/24/11
H
it
O
a
J
Z
O
z
w
z
0
0
v
z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1829
CAREFULLY LIFT (E) WALL UNDERLAYMENT AND
INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF SELF- ADIERING
MEMBRANE. TYP. AT HEAD AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING 4
PAINT TO MATCH (E) SIDING
PRE- PRIMED, GALY. SHEET METAL
FLASHING W/ F.F. END CAPS UNDER
SELF - ADHERING MEMBRANE. EXTEND
FLASHING 4" UP WALL. FIELD PAINT
FLASHING - COLOR TO BE SELECTED IN
THE HELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR WI
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
REMOVE / REPLACE SIDING AS
REQUIRED.
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
(E) WALL UNDERLAYMENT
SELF- ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
INSULATION DAM DETAIL
3" = 1' - 0"
INSULATION
INSULATION DAM
(E) WALL FRAMING
EXISTING VENT COVER
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
EX*iiriED
NEW 2 "X SPACER AS
REQUIRED TO PROVID
6" CLEAR AIR SPACE MA I 2 2012
NEW 2 "X SPACER
LATERAL SECTION
VENT BAFFLE DETAIL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW I" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
1 1/2" = 1' - 0"
RECEIVED
JUL 19 2011
PERMIT CENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
REGTEFED
Ati HITE:CT
rtii°
COTT +iTEMP
STATE OF f THINGTON'•
0810.03.1829
2/24/11
i-
ce
0
0
J
Q
z
0
z
Ct
w
z
0
U
00
z
AIP NUMBER
MPROVEMENTS
0
w
w
ce
w
U)
0
z
LL
J
5 -53- 0058 -043
z
0
C9
z
C/)
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03A 829
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
COMERS, TYP.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOUt4 FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING I -I/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND 1 in
BEYOND R.O. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH R.O. AS
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
Ii" MIN
1.„14,,,2" TYP.
MEMBRANE FLASHING AT SILL
Ji/ 5.. ir
BUTTERFLY COMER FLASHING
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 514OWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLAKE AND
SHOULD FILL FLANGE
NAIL HOLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
At SILL.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
C WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOU1N OVER
FLANGE
FLASHING AT
JAMBS
$� SCALE: NTS
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT NOUN! FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
WHERE RE" [RED, TRIM
(E) BLDG ' APER AT
HEAD TO - PARE
FOR INST • LATION OF
HEAD FL • ING AND
WINDOW TRI
(FOLLOW] ' STEPS).
L J
HEAD FLASHING PREPARATION
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDNG BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING t
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
2 ` MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
j
INSTAL
NAIL F
0
0
0
D 11
0
0
0
L SILL FLANGE FLASHING OVER WINDOW
LANCE AND FLASHING.
INSTALL BHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
TRIMMED EDGE
OF (E) SIDING,
SHOWN
D IAGRAMAT ICAL LY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW I /8" ¢LEARANCE
BETWEEN FLASHING AND
BOT. EDGE bF (E)
SIDING.
(9
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 1 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
J
•
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
6 I MEMBRANE FLASHING AT JAMB
SCALE: NTS
GENERAL NOTES:
I: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADWEARING MEMBRANE FLASHING" TYPICALLY
REFEREE) TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO 514EET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE in GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
0 0
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
MAR 1 2. 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
TOTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, iYA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
EOTT 0= HISTEf,4PE'
HINGTON
STATE
0810.03.1829
2/24/11
Et
0
a
Q
J
Z
0
Z
w
H
Z
Z
0
U
0
Z
AIP NUMBER
MPROVEMENTS
>-
0
w
w
W
0
z
u_
J
cc
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1829
0
O
O
0
0
0
0
0
0 0 0
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
C WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT SHOWN
FOR CLARITY.
LAY (E) BLDG
PAPER BACK
DOU1N OVER
FLANGE
FLASHING AT
JAMBS
$� SCALE: NTS
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT NOUN! FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
r
WHERE RE" [RED, TRIM
(E) BLDG ' APER AT
HEAD TO - PARE
FOR INST • LATION OF
HEAD FL • ING AND
WINDOW TRI
(FOLLOW] ' STEPS).
L J
HEAD FLASHING PREPARATION
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDNG BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING t
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
2 ` MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
j
INSTAL
NAIL F
0
0
0
D 11
0
0
0
L SILL FLANGE FLASHING OVER WINDOW
LANCE AND FLASHING.
INSTALL BHT. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
TRIMMED EDGE
OF (E) SIDING,
SHOWN
D IAGRAMAT ICAL LY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED. ALLOW I /8" ¢LEARANCE
BETWEEN FLASHING AND
BOT. EDGE bF (E)
SIDING.
(9
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 1 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
I -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
J
•
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
6 I MEMBRANE FLASHING AT JAMB
SCALE: NTS
GENERAL NOTES:
I: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADWEARING MEMBRANE FLASHING" TYPICALLY
REFEREE) TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO 514EET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE in GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
0 0
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
MAR 1 2. 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
TOTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, iYA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
EOTT 0= HISTEf,4PE'
HINGTON
STATE
0810.03.1829
2/24/11
Et
0
a
Q
J
Z
0
Z
w
H
Z
Z
0
U
0
Z
AIP NUMBER
MPROVEMENTS
>-
0
w
w
W
0
z
u_
J
cc
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1829
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CI RC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
M TG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1 000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL ABBR
4 I
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
OR XX EQUIPMENT ITEM XX
UNE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
X/Y
l
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 BASEMENT, MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
$G-X XX
DN
1-"` UP I + UP
t f
s
VD
RA /EA
-!N RG
-1*. 4I-F RA /EA
SA
SA
}:j".4
EQUIP IDR `.
II
SD
EA
MOD
NG NG
3
0
•
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISIOP
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
REMARKS
DESCRIPTION
VOLTS
PH
344
<.08 "WG
8 "0
EXTERIOR
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
LOCATION
REMARKS
WC -1
EXTERIOR
120
344
<.08 "WG
8 "0
EXTERIOR
1,2
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1829
2855
3
120 CFM
120 CFM
1
1. VENTILATION PROVIDEI? PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
_
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
Pi '221
EX ED
MAR 1 22012
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / (&EGR X F)
QR = (FROM TABLE 403.8.1) 5.Q
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION la.
QF = 60 / (1 X 1/2) = 120 CFM
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Limited liability company
4000 DELRIDGE WAY SW
BUTTE 200 • SEATTLE, WA 98108
(008)
6114-Wfl' • FAX (208) 524 -2973
THE GREENBUSCH GROUP, INC
)))
wow v_ LIE 201 RIME. 91119
1900 ,IE T i i r WTE 2G1 9LAmr4 IIH19
(206) 378 -0669 (206) 378 -0041 FAX
0810.03.1829
0
0
J
0
i-
<
z
w
z
0
U
z
MPROVEMENTS
0
w
w
w
U)
0
z
ce
i
J
1—
z
w
w
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1829
1 SEE
1
(E)SG
HOLD TIGHT TO
JOISTS AND
(E) DUCT
00
ROUTE UNDER
BEAM AND A OID
DOOR SWING
FAMILY
ROOM
(E)SUPPLY
I \
0
0
BEMENT
(E)SG
CH
FLU E
BEAM
BASEMENT MECHANICAL PLAN
1 SCALE: 1/4" = V-0"
CEILING
J
a_
0
D
in
w
AC
FURNACE
NORTH
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
MOD, INTERLOCK
TO FURNACE
POC
FLU E
FLOOR
OUTSIDE AIR TO FURNACE ELEVATION
SCALE: NONE
BEDROOM
(E)SG
®�
BATH
ESG�
(E)SG
KITCHEN
(E)SG
LIVING
ROOM
(E)SG
DINING
ROOM
(E)sc
(E)SG
11
MAIN FLOOR MECHANICAL PLAN
SCALE: 1 /4" = 1' -0"
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL CAP
SLEEVE AND ESCUTCHEON
WALL
NORTH
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP CONNECTION DETAIL
SCALE: NONE
UPPER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY
OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC
401.5.1.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR
AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO
SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER
51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS
SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT
ENERGIZING OTHER ENERGY— CONSUMING APPLIANCES). COORDINATE FINAL
TIME SETTING WITH PROJECT REPRESENTATIVE.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP.
REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE
OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8.
INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING
FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR
BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED
VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR
TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY
BE REUSED.
NORTH
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
,:z„,,
MAR 1 22012
RECEIVED
JUL 19 2011
PERMIT GINTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional United Liability Company
4000 DELRIDGE WAY SW
SUITS 200 • SEATTLE, WA 98100
(eoe) 624-2777 • FAX (206) eet —awry
THE GREENBUSCH GROUP, INC
)))
taco rear wD10 m dale °,BIN o
(206) 378 -0069 (206) 378 -0041 FAX
0810.03.1829
KING COUNTY INTERNATIONAL AIRPORT
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
0
1—
0
z
W
J
H
W
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
BASEMENT,
MAIN AND
UPPER FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1829
BLACK
WHITE
BK
BLACK
WHITE
RED
BK
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS
AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS
WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED.
ELECTRICAL PLAN NOTES
0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE
DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE
ATTIC.
BLACK
WHITE
1 P
WH �
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
FAMILY
IROOM
PASEMENT
BASEMENT PLAN
1/4" = 1'
1NIE CAN I CAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
WIRE.
BKR
DESCRIP11ON
VOLTS
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
k
15
16
15
16
N/A
15
16
N/A
-
MOTOR OPERATED DAMPER
24
1
X
FIRE ALARM SMOKE DETECTOR 120V OPERATED
-►-
X
ELECTRICAL METER
@
X
A
1,2
-
THERMOSTAT
24
1
X
TO
THERMOSTAT
X
20(1
20/1
X
B
B
1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
4
6
8
9
11
13
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
20/1
1511
15/1
A
A
B
20/1
15 /1
15/1
REMARKS: 1 - VER
2 - DISCONNECT
FY QUANTITY FROM PLANS (TYPICAL ALL)
SWITCH
PEDfROCM
PATH
LIVING
iOOM
NORTH
MAIN FLOOR PLAN
1/4" = 1'
ELECTRICIAN. LEGEND
SYMBOL
DESCRIPTION
SYM8O1.
DESCRIPTION
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
LIGHTING OR POWER PANEL
m
A
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
k
111111
4
DAMPER CONNECTION
❑'
NON -FUSED DISCONNECT SWITCH
O
MAST, WEATHERHEAD
L'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
KVA
BRANCH CIRCUIT HOME RUN
®D
FIRE ALARM SMOKE DETECTOR 120V OPERATED
-►-
cal
ELECTRICAL METER
@
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
A
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
i
TIMER OPERATED SWTCH
- - -
EXISITNG LOAD
2
TO
THERMOSTAT
PANEL
MP
LOCATION:
SERVING:
0810.03.1829
10,000
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
RESIDENCE
AJC,
200
AMP with MAIN
CKT
LOAD DESCRIPTION
TYPE
KVA
AIP
PHASE
PIP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
EXISTING LOAD
30/2
A
15/1
EXISITNG LOAD
2
3
5
7
EXISTING LOAD
EXISTING LOAD
20(1
20/1
A
B
B
15/1
20/1
20/1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
4
6
8
9
11
13
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
20/1
1511
15/1
A
A
B
20/1
15 /1
15/1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
10
12
14
15
17
19
EXISTING LOAD
SMOKEDEi'ECTORS
15/1
2014 **
A
B
B
15/1
20/1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
16
18
20
21
23
25
EXISTING LOAD
EXISTING LOAD
20/1 -20/1
30/2
A
A
B
20/1
20 /1
20/1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
22
24
26
27
29
31
EXISTING LOAD
30/2
A
B
B
2011
20/1
20/1
EXISITNG LOAD
EXISITNG LOAD
EXISITNG LOAD
28
30
32
33
PHASE LOAD PHASE A=
#VALUE!
KVA,
PHASE B=
A
KVA.
60/2
EXISITNG LOAD
34
LOAD TYPE
L
R .
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑
ISOLATED GROUND BUS
RAINTIGHT NEMA -3R ENCLOSURE
FEED THRU LUGS
DOUBLE LUGS
MAIN BKR SHUNT TRIP
SERVICE ENTRANCE LABEL
PANEL SKIRTS
INTEGRAL
SURFACE
FLUSH
■
■
■
■
■
■
■
■
TVSS ■
REMARKS:
** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM.
Zug
4TTIC
CONNECT TO
LOITER CIRCUIT -\
SEDIROOM
3
ATTIC
ATTIC
PEDROOM
2
MAR 1 2201
4'844 7-
£lPo
RECEIVED
JUL 19 2011
PERMITCENTER
S.MSTEMPER
ARCHITE CTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
IN ENGINEERS. INC
snsui#.si w wan a
WPM ."". WWWANA
i NW
Mili IMO 4M MN
0810.03.1829
LL
O
L.L
J
z
0
I-
Q
z
W
z
z
O
U
O
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
z
0
z
C!)
W
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1829