Loading...
HomeMy WebLinkAboutPermit D11-228 - BAKER RESIDENCE - UPGRADESBAKER RESIDENCE 11662 42 AV S EXPIRED 03 -12 -12 Dl 1 -228 Parcel No.: Address: Suite No: Project Name: City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 3347400185 11662 42 AV S TUKW BAKER RESIDENCE DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D11 -228 09/14/2011 03/12/2012 Owner: Name: Address: BAKER ROGER E 11662 42ND AVE S , TUKWILA WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $28,890.00 Type of Fire Protection: NONE Type of Construction: V -B Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: International Building Code Edition: Occupancy per IBC: $1,067.51 2009 0022 * *continued on next page ** doc: IBC -7/10 D11 -228 Printed: 09 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie r • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or the performance of work. to this permit. Signatur e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: 7 /yhl Print Name: --c-e4 6i: 4i9/1 -6- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-228 Printed: 09 -14 -2011 this requirement. III • 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -228 Printed: 09 -14 -2011 CITY OF TUKWILI. Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.waus Building Permit No. 9 Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 3347400185 Site Address: 11662 42nd Ave. S. Tenant Name: Roger E. Baker Property Owners Name: Roger E. Baker Suite Number: Floor: New Tenant: ❑ Yes 0 ..No Mailing Address: 11662 42nd Ave. S. Tukwila WA 98168 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:Wpplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORNt. .'ION 206- 431 -3670 Valuation of Project (contractor's bid price): $ 28,890 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1't Floor 975 2n° Floor 3rd Floor Floors thru " Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application doc Revised: 1-2009 bh Page 2 of 6 PLUMBING AND GAS PIPINC ERMIT INFORMATION - 206 -431 7 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: not yet awarded City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:Wpplications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT 11/ ' / AGENT: er Timo J. Fenlason Stemper Architects, PLLC Signature. Print Name: Mailing Address: 4000 Delridge ay SW, Suite 200 Date: Day Telephone: (206) 624 -2777 Seattle WA 98106 City State Zip Date Application Accepted: 1 � I t I Date Application Expires: 1--4 9- Staff Initials: r', II - H:\Applications\Fonns- Applications On Line\2009 Applications \ 1-2009 -Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 Citbof Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwi' Washington 98188 Phone. .,6- 431 -3670 Fax: 206-431-3665 Web site: httn: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011 RECEIPT NO: R11 -01600 Initials: WER Payment Date: 07/28/2011 User ID: 1655 Total Payment: 13,064.48 Payee: PAMELA K KUEHL SET ID: 071911 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D11 -222 748.15 D11 -223 716.64 D11 -224 1,092.10 D11 -225 993.76 D11 -226 622.10 D11 -227 653.61 D11 -228 1,067.51 D11 -229 685.13 D11 -230 685.13 D11 -231 716.64 D11 -232 1,018.34 D11 -233 559.07 D11 -234 811.18 D11 -235 1,042.93 D11 -236 1,652.19 TOTAL: -/•= 8-15-- TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,064.48 TOTAL: 13,064.48 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 7,876.95 000.345.830 5,120.03 640.237.114 67.50 TOTAL: 13,064.48 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D11 -228 BAKER RESIDENCE 11662 42 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fifer Marshall it Technician File: Permit File No. DI 1 -228 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 1 PE w.fi l COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -228 DATE: 07 -19 -11 PROJECT NAME: BAKER RESIDENCE SITE ADDRESS: 11662 42 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: i ding 1i ision T1 ti N x Cr1, Public Works ire Pre eh on 1� II Structural DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Planning Division Permit Coordinator DUE DATE: 07 -21 -11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 08-18 -11 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 • General /Specialty Contractor A business registered as a construction contractor with LW to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135245 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011 KING COUNTY NTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: Mechanical lectrical numbing as Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT : f svisians will require a new plan submittal and may include additional plan review fees, FILE COPY Permit No. 8 Plan review approval Is subject to errors and omissions. Ap:irova1 of construction documents does not authorize t� ;• c' ,t an of any adopted code or ordinance. Receipt a approved FiQlci.%.,.�* knowledgcd: City Of l icwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, 1114 APPLICABLE CODES: 2009 International Residential Code, international Fire Code, international Mechanical Code 3341400185 LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV • 1 ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE 22NStii1,lCTION TYPE: (No Change) v B NON SPRINKLERED DUiLDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: MAR .1 22012 DRAWING INDEX T0.0 A1.0 A2.0 42.1 A22 A23 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBREv, GENERAL NOTES 4 DWG INDEX M2.0 BASEMENT, MAN, AND UPPER FLOOR MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle 1114 98108 Pig 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: Sharyn.Parkerekingcounty.gov ARCHITECT: S.M. Stemper Architects P1.L.C. 4000 Perridga Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryeamstemper.com melodyesmstemper.com tlmesmstempercom ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua ELECTRICAL ENGINEER Tres Went Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 96.409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: mohamedessaacoustics.com E -mall: bcretreswest.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: aria Ager E -mail: ChrlaAegreenbuschcom REGULATED MATERIALS: PBS Engineering and Environmental 2811 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E- mail:. tiro ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 4100 Boston, MA 02114 Contact: Tim Fenlaeon/ Jim Cornwell E -mail: JCornwellejonespayns.com VICINITY MAP (NTS) RECEIVE JUL 1/�9 2011 0 ,wni`v� iTCENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (20B) 624 -2973 4220 ,m/Pr SCOT. # STATE;. OF 0810.03.1829 TEMPE wi „NGTDNii 2/24/11 H CL 0 CL ct Nt 7=t z 0 ct z w z KING COUNTY z w 0 0 0 w w w C/) O Z w 0 LLl AIP NUMBER 5- 53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1829 (E) FAMILY ROOM BASEMENT FLW PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. NW A MO S NT PLAN 1/4" = 1' 1- 0 0 NOTE: 1. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081. BEDROOM 1 (E) CLOSET 1— w d) 0 0 BATH (E) ( KITCHEN LIVING ROOM (I) 0 DINING ROOM (E) MAIN FLOOR PLAN 1/4" = 1' NOTE: INTERIOR TRIM TO BE FINISHED OAK NOTE: SECURITY ALARM SYSTEM PRESENT. COORDINATE WITH HOMEOWNER FOR TEMPORARY DISCONNECTION AND RECONNECTION OF THE SECURITY SYSTEM PRIOR TO START OF WORK GENERAL NOTES I. CONTRACTOR TO PROTECT OU1 ERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. B. ALL WORK AREAS 514ALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. II. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET Alm FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. I. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POLIER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M. I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECI- INICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY A5 COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. ( ATTIC 0 0 BEDROOM 3 V r 1- N 0 0 ATTIC (E) BEDROOM 2 ATTIC UPPER FLOOR PLAN 1/4 "= 1' 26' -3" 61 N I— H H L_ __1/ \ / \ / \ / \ i u \ 1 11 �L 11 6' -2" H H / J / :– -.- -, -, - - -.- ^IF Z —_ —.— 4 / r FILJ \ -1 1 ROOF PLAN 1/4" = 1' L _ 1// \ MAR •1 2'2012 A. WEST ELEVATION C. EAST ELEVATION PLAN KEYNOTES 0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42,0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, MD STORM DOOR REF. DOOR SCHEDULE ON SHEET 42.1 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/A2.2 FOR DETAIL. COORDINATE WITH j MECHANICAL. 0 NSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. c INSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER OINSTALL FIREPLACE CAP .4T (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. c:: INSTALL VENT BAFFLE(S) AT EXISTING RIDGE VENT(S) IN ATTIC, RIcF. 3/A22 FOR DETAIL. O & DEMOLISH EXISTING DOOR(5), INSTALL NEW ATTIC ACCESS PANEL DOOR(S) REF. DOOR SCHEDULE ON SHEET A2.I. FLUSH SOLID CORE INTERIOR WOOD DOOR rq t. tooll'` 90.mf.i.t ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND TI4EIR SUBCONTRACTORS SHALL NOT PARK OR B_OCK ACCESS TO HOMEOWNER DRIVEWAY. B. NORTH ELEVATION D. SOUTH ELEVATION LEGEND 1 1 ACOUSTICAL WINDOW NOT USED EXTERIOR/ INTERIOR/ STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. 42.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE NOT USED REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 ATTIC INSULATION PE`- `y +'TCE TER SO INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED AS GAS METER w S.M.STEMPER ARCHITECTS A Prateasional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED A HITE:CT 0810.03.1829 2/24/11 Il 0 Ct J E 0 F'— LL w F- E z 0 E MPROVEMENTS FT NOISE REMEDY ct J z w 0 (75 w AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1829 WINDOW TYPES COTTAGE 2 FIXED 3 SLIDER 4 SINGLE HUNG WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 1' -0 x 4' -5" STAIN/PAINT - 2/A2.0 B LIVING ROOM 1 3' -0" x 4' -5" STAIN/PAINT 2/42.0 C BEDROOM I 2 3' -4" x 1' -9" STAIN/PAINT 2/42.0 D BEDROOM I 4 4' -0" x 4' -5" STAIN/PAINT y 2/A2.0 E KITCHEN 4 3' -2" x 3' -6" STAIN/PAINT 2/4.2.0 F KITCHEN 4 3' -2" x 4' -2" STAIN/PAINT 2/42.0 G KITCHEN 4 2' -9" x 2' -6" STAIN/PAINT 2/A2.0 14 DINING ROOM 2 1' -0" x 4' -5" STAIN/PAINT 2 /A2.0 I LIVING ROOM 2 2' -0" x 1' -9" STAIN/PAINT 2/42.0 J LIVING ROOM 2 2' -0" x 1' -9" STAIN/PAINT 2/A2.0 K LIVING ROOM 2 1' -0 x 4' -5" STAIN/PAINT SAFETY GLAZING REQUIRED 2/42.0 L FAMILY ROOM 3 4' -0" x 11-6" STAIN/PAINT SAFETY GLAZING REQUIRED 3/42.0 M FAMILY ROOM 3 4' -0" x 1' -6" STAIN/PAINT SAFETY GLAZING REQUIRED 3/4210 N HALLWAY/ LANDING 3 4' -2" x 3' -V STAIN/PAINT SAFETY GLAZING REQUIRED 1/A2.0 0 BEDROOM 2 3 4' -2" x 3' -7" STAIN/PAINT SAFETY GLAZING REQUIRED y 1/42.0 P BEDROOM 3 3 4' -2" x 3' -7" STAIN/PAINT SAFETY GLAZING REQUIRED Y 1/A2.0 Q KITCHEN ENTRY 2 1' -6" x 3' -0" STAIN/PAINT SAFETY GLAZING REQUIRED 1/A2.0 (E) = EXISTING NOTE: ADD A 2X WOOD FRAME TO WINDOWS N, 0, AND P TO MAKE THE WIDTH 48" TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN TI.4AT UNIT ARE TO 8E TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, 8UT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. War IfIf EXISTING SOFFIT AND FRAME SEALANT VZLIZZLZGI TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED ACOUSTICAL WINDOW ASSEMBLY r- CAREFULLY GUT BACK (E) WD. SIDING t0 ALLOW FOR REATTACHMENT t0 RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (,E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY GRAMS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN u 11 III I � WINDOW HEAD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING L I II WINDOW JAMB IX WOOD LINER WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IUD. JAMB LINING. FINISH TO MATCH (E) SEALANT 4 BACKER ROD (E)GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD JAMB LINING SEALANT SHIM A5 NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD 4 SEALANT 3 /8" 3/4" WD. SILL - STAIN TO MATCH (E) WINDOW SILL WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING �J PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E) GWB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WOOD TRIM TO MATCH E), PAINT /STAIN TO MATCH (E) TRIM ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN -------`- WINDOW HEAD WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) WP SIDING II WINDOW JAMB (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP 111/ BATT INSULATION ICI 3/8" 3/4" WD. SILL - STAIN TO wiloi �111 MATCH (E) '411111c111 WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT WINDOW SILL SELF- ADHERING MEMBRANE (E) GWB WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD (E) GUS (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER I4EADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY WINDOW HEAD MEMBRANE WOOD TRIM TO MATCH E), PAINT /STAIN TO MATCH (E) TRIM WD. JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION ACOUSTICAL WINDOW ASSEMBLY. USE TAP -CON SCREWS FOR INSTALLATION At (E) CMU WALL n r ICJ 11 11 I II I WINDOW JAMB (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IUD JAMB LINING SEALANT SH111 AS NECESSARY FILL GAP W/ BATT INSULATION EXPIRED BACKER ROD AND SEALANT 2 "X8" PRESSURE TREATED WOOD ii «1 i I r «<rii i i i �� A MAR 1 2 2012 REVIEWED FOR CODE COMPLIANC APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISIO SEALANT 4 BACKER ROD 3/8" MIN. /4" WOOD SILL PAINT /STAIN TO MATCH (E) TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED FLEX FLASHING REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING. PAINT TO MATCH (E) SIDING (E) CONCRETE WALL WINDOW SILL WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0„ GUS EDGE METAL CUT (E) GWB AS REQUIRED. PATCH TO MATCH (E) TEXTURE AND PAINT FULL EXTENT OF WALL TO MATCH (E) WALL COLOR TAPE AND FEATHER MUD JOINT RECEIVE JUL 19 201 PERMITCENTI D S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • PAX (208) 824 -2973 422,0 COTT STATE OF 0810.03.1829 REGISTERED Aa HITEICT TEMPE SHINGTON 2/24/11 ct 0 0 ce —J z 0 Q z W z z 0 U (9 z MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 z 0 0 z co DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1829 DOOR TYPES 0 A FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW HALF -LITE W/ 2 PANELS W/ SAFETY GLAZING C EXTERIOR SINGLE LEAF STORM W/ SAFETY GRILLE FLUSH SCW INTERIOR DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -S" STAIN/STAIN 1-1W -1 / 612 DK -2 LOCK -1 I /A2J 2 KITCHEN ENTRY B 2' -8" x 6' -8" STAIN/STAIN 1-111J-1 / 612 DK -2 LOCK -1 1/A2.1 3 ENTRY C 3' -0" x 6' -S" STAIN/STAIN 1 /A2J 4 KITCHEN ENTRY c 2' -S" x 6' -8" STAIN/STAIN 1/A2J 5 HALL (attic access) D 2' -0" x 4' -6" STAIN/STAIN HW -2 / 612 DK- 5(Access Door) N/A 2/A2.1 6 EEDROOM 2 (attic access) D 2' -0" x 4' -6" STAIN/STAIN HW -2 / 612 DK- 5(Access Door) N/A 2 /A2.1 1 HALL (attic access) D 2' -0" x 4' -6" STAIN/STAIN HW -2 / 612 DK- 5(Accees Door) N/A 2/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 1 TRIM. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE MELD CONTINUOUS SEALANT BEHIND Z BAR FRAME ST0101 DOOR PER SCHEDULE 2" MIN. SELF - ADHERING MEMBRANE (E) EXTERIOR SHEATHING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB 51-11M AS NECESSARY FILL GAP W/ GATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FRAMING EXISTING FLOOR STRUCTURE DOOR SILL WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM 514IM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3 "= 1' -0" CONTINUOUS WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KERF IN CONTINUOUS WEATHER STRIPPING WOOD BLOCKING CONTINUOUS WOOD TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KERF IN CONTINUOUS WEATI4ER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR HEAD EXISTING FRAMING DOOR JAMB DOOR SILL CONTINUOUS WOOD TRIM INTERIOR DOOR PER SCHEDULE EXISTING FRAMING CONTINUOUS WOOD TRIM DOOR PER SCHEDULE ATTIC ACCESS - DOOR DETAIL SET 3 " =1' -0" ill -J.2.1 EX IRED MAR 1 22012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 HITEICT COTT V4TEM.PE'' STATE OE ! HINGTO 0810.03.1829 2/24/11 H it O a J Z O z w z 0 0 v z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1829 CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADIERING MEMBRANE. TYP. AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALY. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF - ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL. FIELD PAINT FLASHING - COLOR TO BE SELECTED IN THE HELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR WI ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. REMOVE / REPLACE SIDING AS REQUIRED. EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS (E) WALL UNDERLAYMENT SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" INSULATION DAM DETAIL 3" = 1' - 0" INSULATION INSULATION DAM (E) WALL FRAMING EXISTING VENT COVER EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION EX*iiriED NEW 2 "X SPACER AS REQUIRED TO PROVID 6" CLEAR AIR SPACE MA I 2 2012 NEW 2 "X SPACER LATERAL SECTION VENT BAFFLE DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION 6" MIN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. 1 1/2" = 1' - 0" RECEIVED JUL 19 2011 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 REGTEFED Ati HITE:CT rtii° COTT +iTEMP STATE OF f THINGTON'• 0810.03.1829 2/24/11 i- ce 0 0 J Q z 0 z Ct w z 0 U 00 z AIP NUMBER MPROVEMENTS 0 w w ce w U) 0 z LL J 5 -53- 0058 -043 z 0 C9 z C/) DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03A 829 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY COMERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUt4 FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING I -I/2" OVER (E) BLDG. PAPER AT SILL. EXTEND 1 in BEYOND R.O. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH R.O. AS ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING Ii" MIN 1.„14,,,2" TYP. MEMBRANE FLASHING AT SILL Ji/ 5.. ir BUTTERFLY COMER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 514OWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLAKE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER At SILL. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES C WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOU1N OVER FLANGE FLASHING AT JAMBS $� SCALE: NTS MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT NOUN! FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r WHERE RE" [RED, TRIM (E) BLDG ' APER AT HEAD TO - PARE FOR INST • LATION OF HEAD FL • ING AND WINDOW TRI (FOLLOW] ' STEPS). L J HEAD FLASHING PREPARATION (E) BLDG. PAPER NOTE: REMOVE (E) SIDNG BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING t FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 ` MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. j INSTAL NAIL F 0 0 0 D 11 0 0 0 L SILL FLANGE FLASHING OVER WINDOW LANCE AND FLASHING. INSTALL BHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS TRIMMED EDGE OF (E) SIDING, SHOWN D IAGRAMAT ICAL LY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I /8" ¢LEARANCE BETWEEN FLASHING AND BOT. EDGE bF (E) SIDING. (9 HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 1 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. J • — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 6 I MEMBRANE FLASHING AT JAMB SCALE: NTS GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADWEARING MEMBRANE FLASHING" TYPICALLY REFEREE) TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO 514EET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE in GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. 0 0 J WINDOW FLASHING INSTALLATION SCALE: NTS MAR 1 2. 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 TOTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, iYA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED EOTT 0= HISTEf,4PE' HINGTON STATE 0810.03.1829 2/24/11 Et 0 a Q J Z 0 Z w H Z Z 0 U 0 Z AIP NUMBER MPROVEMENTS >- 0 w w W 0 z u_ J cc 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1829 0 O O 0 0 0 0 0 0 0 0 ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES C WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOU1N OVER FLANGE FLASHING AT JAMBS $� SCALE: NTS MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT NOUN! FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. r WHERE RE" [RED, TRIM (E) BLDG ' APER AT HEAD TO - PARE FOR INST • LATION OF HEAD FL • ING AND WINDOW TRI (FOLLOW] ' STEPS). L J HEAD FLASHING PREPARATION (E) BLDG. PAPER NOTE: REMOVE (E) SIDNG BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING t FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING 2 ` MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. j INSTAL NAIL F 0 0 0 D 11 0 0 0 L SILL FLANGE FLASHING OVER WINDOW LANCE AND FLASHING. INSTALL BHT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS TRIMMED EDGE OF (E) SIDING, SHOWN D IAGRAMAT ICAL LY. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. ALLOW I /8" ¢LEARANCE BETWEEN FLASHING AND BOT. EDGE bF (E) SIDING. (9 HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 1 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. J • — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 6 I MEMBRANE FLASHING AT JAMB SCALE: NTS GENERAL NOTES: I: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADWEARING MEMBRANE FLASHING" TYPICALLY REFEREE) TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO 514EET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE in GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. 0 0 J WINDOW FLASHING INSTALLATION SCALE: NTS MAR 1 2. 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 TOTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, iYA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED EOTT 0= HISTEf,4PE' HINGTON STATE 0810.03.1829 2/24/11 Et 0 a Q J Z 0 Z w H Z Z 0 U 0 Z AIP NUMBER MPROVEMENTS >- 0 w w W 0 z u_ J cc 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1829 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1 000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR 4 I DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW OR XX EQUIPMENT ITEM XX UNE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y l EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 BASEMENT, MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL $G-X XX DN 1-"` UP I + UP t f s VD RA /EA -!N RG -1*. 4I-F RA /EA SA SA }:j".4 EQUIP IDR `. II SD EA MOD NG NG 3 0 • D'4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISIOP INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 344 <.08 "WG 8 "0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 120 344 <.08 "WG 8 "0 EXTERIOR 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1829 2855 3 120 CFM 120 CFM 1 1. VENTILATION PROVIDEI? PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 _ NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. Pi '221 EX ED MAR 1 22012 THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) 5.Q &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION la. QF = 60 / (1 X 1/2) = 120 CFM RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Limited liability company 4000 DELRIDGE WAY SW BUTTE 200 • SEATTLE, WA 98108 (008) 6114-Wfl' • FAX (208) 524 -2973 THE GREENBUSCH GROUP, INC ))) wow v_ LIE 201 RIME. 91119 1900 ,IE T i i r WTE 2G1 9LAmr4 IIH19 (206) 378 -0669 (206) 378 -0041 FAX 0810.03.1829 0 0 J 0 i- < z w z 0 U z MPROVEMENTS 0 w w w U) 0 z ce i J 1— z w w AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1829 1 SEE 1 (E)SG HOLD TIGHT TO JOISTS AND (E) DUCT 00 ROUTE UNDER BEAM AND A OID DOOR SWING FAMILY ROOM (E)SUPPLY I \ 0 0 BEMENT (E)SG CH FLU E BEAM BASEMENT MECHANICAL PLAN 1 SCALE: 1/4" = V-0" CEILING J a_ 0 D in w AC FURNACE NORTH VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN MOD, INTERLOCK TO FURNACE POC FLU E FLOOR OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE BEDROOM (E)SG ®� BATH ESG� (E)SG KITCHEN (E)SG LIVING ROOM (E)SG DINING ROOM (E)sc (E)SG 11 MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NORTH NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP CONNECTION DETAIL SCALE: NONE UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY— CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. NORTH SEPARATE PERMIT AND APPROVAL REQUIRED ,:z„,, MAR 1 22012 RECEIVED JUL 19 2011 PERMIT GINTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional United Liability Company 4000 DELRIDGE WAY SW SUITS 200 • SEATTLE, WA 98100 (eoe) 624-2777 • FAX (206) eet —awry THE GREENBUSCH GROUP, INC ))) taco rear wD10 m dale °,BIN o (206) 378 -0069 (206) 378 -0041 FAX 0810.03.1829 KING COUNTY INTERNATIONAL AIRPORT MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 1— 0 z W J H W DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA BASEMENT, MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1829 BLACK WHITE BK BLACK WHITE RED BK ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. 0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH. 0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. BLACK WHITE 1 P WH � SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED FAMILY IROOM PASEMENT BASEMENT PLAN 1/4" = 1' 1NIE CAN I CAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION WIRE. BKR DESCRIP11ON VOLTS PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. k 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X FIRE ALARM SMOKE DETECTOR 120V OPERATED -►- X ELECTRICAL METER @ X A 1,2 - THERMOSTAT 24 1 X TO THERMOSTAT X 20(1 20/1 X B B 1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 4 6 8 9 11 13 EXISTING LOAD EXISTING LOAD EXISTING LOAD 20/1 1511 15/1 A A B 20/1 15 /1 15/1 REMARKS: 1 - VER 2 - DISCONNECT FY QUANTITY FROM PLANS (TYPICAL ALL) SWITCH PEDfROCM PATH LIVING iOOM NORTH MAIN FLOOR PLAN 1/4" = 1' ELECTRICIAN. LEGEND SYMBOL DESCRIPTION SYM8O1. DESCRIPTION 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G LIGHTING OR POWER PANEL m A EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. X12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. k 111111 4 DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH O MAST, WEATHERHEAD L' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS KVA BRANCH CIRCUIT HOME RUN ®D FIRE ALARM SMOKE DETECTOR 120V OPERATED -►- cal ELECTRICAL METER @ FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED A AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. i TIMER OPERATED SWTCH - - - EXISITNG LOAD 2 TO THERMOSTAT PANEL MP LOCATION: SERVING: 0810.03.1829 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR RESIDENCE AJC, 200 AMP with MAIN CKT LOAD DESCRIPTION TYPE KVA AIP PHASE PIP KVA TYPE LOAD DESCRIPTION CKT 1 EXISTING LOAD 30/2 A 15/1 EXISITNG LOAD 2 3 5 7 EXISTING LOAD EXISTING LOAD 20(1 20/1 A B B 15/1 20/1 20/1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 4 6 8 9 11 13 EXISTING LOAD EXISTING LOAD EXISTING LOAD 20/1 1511 15/1 A A B 20/1 15 /1 15/1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 10 12 14 15 17 19 EXISTING LOAD SMOKEDEi'ECTORS 15/1 2014 ** A B B 15/1 20/1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 16 18 20 21 23 25 EXISTING LOAD EXISTING LOAD 20/1 -20/1 30/2 A A B 20/1 20 /1 20/1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 22 24 26 27 29 31 EXISTING LOAD 30/2 A B B 2011 20/1 20/1 EXISITNG LOAD EXISITNG LOAD EXISITNG LOAD 28 30 32 33 PHASE LOAD PHASE A= #VALUE! KVA, PHASE B= A KVA. 60/2 EXISITNG LOAD 34 LOAD TYPE L R . M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS RAINTIGHT NEMA -3R ENCLOSURE FEED THRU LUGS DOUBLE LUGS MAIN BKR SHUNT TRIP SERVICE ENTRANCE LABEL PANEL SKIRTS INTEGRAL SURFACE FLUSH ■ ■ ■ ■ ■ ■ ■ ■ TVSS ■ REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. Zug 4TTIC CONNECT TO LOITER CIRCUIT -\ SEDIROOM 3 ATTIC ATTIC PEDROOM 2 MAR 1 2201 4'844 7- £lPo RECEIVED JUL 19 2011 PERMITCENTER S.MSTEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 IN ENGINEERS. INC snsui#.si w wan a WPM ."". WWWANA i NW Mili IMO 4M MN 0810.03.1829 LL O L.L J z 0 I- Q z W z z O U O z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 z C!) W DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1829