HomeMy WebLinkAboutPermit D11-231 - ENYEART RESIDENCE - UPGRADESENYEART RESIDENCE
11818 44 AV S
EXPIRED 03 -12 -12
D11 -231
City Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3347400985
Address: 11818 44 AV S TUICW
Suite No:
Project Name: ENYEART RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D11 -231
Issue Date: 09/14/2011
Permit Expires On: 03/12/2012
Owner:
Name: ENYEART JADANNE L
Address: 30118 27TH S , FEDERAL WAY WA 98003
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $17,932.00 Fees Collected: $716.64
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D11-231 Printed: 09 -14 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
N
N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
Number: 0
Start Time:
Volumes: Cut 0 c.y.
Size (Inches): 0
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
I hereby certify that I have read an ex
governing this work will be compli d wit
The granting of this permit does not . es
construction or the performance of wor
ernut.
to this p
Signature:
Public:
Non - Profit: N
Public:
Date: 091Iwlli
ed this permit and know the same to be true and correct. All provisions of law and ordinances
, whether specified herein or not.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
am authorized to sign and obtain this development permit and agree to the conditions attached
Print Name:
Date: 7 //q/0
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-231 Printed: 09 -14 -2011
this requirement.
• 0
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Thkwila
Building Department (206- 431 - 3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -231 Printed: 09 -14 -2011
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Asoft
Building Permit No.
Mechanical Permit No.
Plumbing /Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
1
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address: 11818 44th Ave. S.
Tenant Name: Jadanne L. Enyeart
Property Owners Name: Jadanne L. Enyeart
Mailing Address: 11818 44th Ave. S.
King Co Assessor's Tax No.: 3347400985
Suite Number: Floor:
New Tenant: ❑ Yes
Tukwila
WA
City
State
No
98178
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA
98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised. 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFOR1L ION - 206 -431 -3670
Valuation of Project (contractor's bid price): $ 1 7,932 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
10.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None El Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
HAApplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised. 1 -2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
15` Floor
745
2nd Floor
3'd Floor
Floors thru '
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None El Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
HAApplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised. 1 -2009
bh
Page 2 of 6
PLUMBING AND GAS PIPIN "ERMIT INFORMATION - 206-431 1 70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and /or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:\Applications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc
Revised: 1 -2009
bh
Page 5 of 6
oW I
PERMIT APPLICATION NOTES - Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR A
ED - NT:
Print Name: Ti • •thy J. Fenla J • , SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777
Signature:
Date:
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
City
State
Zip
IDate Application Accepted:
`1-(9- ( (
Date Application Expires:
Staff Initials:
H. \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
Page 6 of 6
CitOof Tukwila.
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http : //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011
RECEIPT NO: R11 -01600
Initials: WER
Payment Date: 07/28/2011
User ID: 1655 Total Payment: 13,064.48
Payee: PAMELA K KUEHL
SET ID: 071911 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D11 -222 748.15
D11 -223 716.64
D11 -224 1,092.10
D11 -225 993.76
D11 -226 622.10
D11 -227 653.61
D11 -228 1,067.51
D11 -229 685.13
D11 -230 685.13
D11 -231 716.64
D11 -232 1,018.34
D11 -233 559.07
D11 -234 811.18
D11 -235 1,042.93
D11 -236 1,652.19
TOTAL:
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 13,064.48
TOTAL: 13,064.48
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 7,876.95
000.345.830 5,120.03
640.237.114 67.50
TOTAL: 13,064.48
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D11 -231
ENYEART RESIDENCE
1181844 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 03/12/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 03/12/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
ifer Marshall
it Technician
File:
Permit File No. D11 -231
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
40 GOP
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -231 DATE: 07- 19 -11.
PROJECT NAME: ENYEAKIvRESIDENCE
SITE ADDRESS: 11818 44 AV S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit. Issued
DEPARTMENTS:
ET AwC
uTding Division °1'
Public Works
NIA- in -
iF re Prevention
Structural
1.
QV— Or 01.24.i
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 07 -21 -1 1
Not Applicable n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route
Structural Review Required
REVIEWER'S INITIALS:
nNo further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 08-18-11
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page Page 1 of 1
•
1
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135245
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
Landmark
American Ins Co
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M
5- 53- 0058 -043
SEPARATE. PERMIT
REQUIRED FOR:
(Mechanical
electrical
Plumbing
Was Piping
City of Tukwila
BUILDING DIVISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOT": Revisions will require a new plan submittal
and may Include additional plan review fees.
FIL COPY
Permit No. . )„4 l
Phri r vIew approval is sublat to errors and omissions.
t roval of construction documents does not authorize
I olation of any adopted code or =finance. Receipt
of approved Field +`i is acknowledged:
By /!
i
Date:
City Of Tltkwila
BUILDING DIVISION
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG o 3 2011
A)S
City of Tukwila
BUILDING DIVISION
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
international Fire Code,
international Mechanical Code
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTRUCTION TYPE: (No Chance)
V 5 NON SPRINKLERED
3341400985
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV • 1 W 140 FT OF FOLD 3 AND N 30 FT OF 4
BUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
MAR .1 2. 2012
DRAWING INDEX
T0.0
41.0
42.0
A2.1
42.2
42.3
TITLE SHEET, PROJECT INFO.
FLOOR PLANS 4 NOTES
WINDOW TYPES, SCHEDULE 4 DETAILS
DOOR TYPES, SCHEDULE 4 DETAILS
MISCELLANEOUS DETAILS
WINDOW FLASHING DETAILS
M1.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX
M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS
E1.0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County international Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296.0190
Contact: Sharyn Parker
E-mail: &harynParlcereklngcounty .gov
ARCHITECT:
S,M. &temper Architects PLL.C.
4000 Delrldge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624. 2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyasmstemper.com
tlmeemstemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839 0819
Fax: 206.839.0824
Contact:. Mohamed Alt Allaoua
E -mail: mohamedassaacoustics.com
MECHANICAL ENGINEER:
The Greerbusch Group
1900 West Nickerson St., Suite 201
Seattle, WA 98119
Ph: 206. 315. 0569
Fax: 206.318.0641
Contact: Chris Ager
E -mail: Chr1sAegreenbuschcom
ELECTRICAL ENGINEER
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcratreswest.com
REGULATED MATERIALS:
P8S Engineering and Environmental
2511 Eastlake Ave. Ey Suite 100
Seattle, WA 98102
Ph 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E -mail: tim ogdenapbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. +'200
Boston, MA 02114
Contact: Tim Fenlason/ Jim Cornell
E -mail: JCornwellaJonespayne.com
ECEIVED
JUL 19 2011
P4`l,R�'V�E f
TCTR
b 11-9
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 824 -2777 • FAX (208) 824 -2973
REGISTERED.
bill''
.,Con # TEMPE•
SATE .O f 11!NGTDN ..
0810.03.1832
2/24111
i--
0
aC
—J
z
z
w
z'
z
0
0
z
MPROVEMENTS
AIP NUMBER
5- 53- 0058 -043
z
0
z
1—
LJJ
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
0810.03.1832
PRIOR TO COMMENCING WITH
DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
I. CONTRACTOR TO PROTECT GONERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. I- IMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 0:00 AM EACH DAY.
I4CMEOWNERS WILL HAVE COMPLETE ACCESS TO TI4E RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00 P11.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY.
'3. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS I- IATCI -{E5.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SWEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POUER OUTAGE I5 EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M.
I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11 CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
13 EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
CLOSET
BEDROOM
BATH
1-
w
N
0
1)
LAUNDRY
ROOM
11
NEW ELECTRICAL
PANEL
KITCHEN
(E) STOVE
24" x 24" EXIST. ATTIC
ACCESS PANEL
LIVING
ROOM
MAIN FLOOR PLAN
1 /4" = 1'
0
A. EAST ELEVATION
B. SOUTH ELEVATION
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0
ODEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET A2.I
OBLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC,REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND
DISCONNECT. REF. 5/A2.2 FOR DETAIL.
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I /422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
OINSTALL VENT BAFFLE(5) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/422 FOR DETAIL.
OINSTALL VENT BAFFLE(5) AT EXISTING RIDGE VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL.
IDCOORDINATE CEILING GRILL WITH MECHANICAL.
OSURPLUS BOTH (E) LIVING ROOM AND LAUNDRY ROOM DOORS TO HOMEOWNER
OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
ACCESS TO SITE AND PARKING
1. NE CONTRACTOR MD THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
16'-5"
3' -10"
E
r
r
I1
J
I
-RAISE INSULATION -
- CU IC4EIGWT AT . .
EXLS . ,14Ttic ?ICCES
P LI.
�r
ri
-
24" x 24" EXIST. ATTIC
ACCESS PANEL
1
1
IA
J
I
L_
i r
L
dl
v
ATTIC PLAN
1/4" = 1'
MAR .1 22012
L
C. WEST ELEVATION
pl\
D. NORTH ELEVATION
LEGEND
r
J _.._.__ ACOUSTICAL WINDOW
-�- I NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.1
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
VENT BAFFLE
•
IGAS
NOT USED
NOT USED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
arm INSULATIOI ERMIT CENTER
INSTALL BATTERY OPERATED SMOKE
DETECTORS
NOT USED
GAS METER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A ''HITECT
0810.03.1832
TEMP
SHINGTON •
2/24/11
NTERNATIONAL AIRPORT
KING COUNTY
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
A A, LB &J H
FLOOR
PLANS
NOTES
A1.0
0810.03.1832
WINDOW TYPES
18" MIN.
SINGLE HUNG/ FIXED /SINGLE HUNG
2
SINGLE HUNG
3
SLIDER
4
CASEMENT
WINDOW SCHEDULE
1
ROOM
WIND.
f
TRIM FINISH
f
EGRESS
DETAIL
SINGLE HUNG/ FIXED /SINGLE HUNG
2
SINGLE HUNG
3
SLIDER
4
CASEMENT
WINDOW SCHEDULE
WIND.
ROOM
WIND.
SIZE
TRIM FINISH
REMARKS
EGRESS
DETAIL
NO
LOCATION
TYPE
W x H
INT./ EXT.
SET
A
LIVING ROOM
I
6' -0" x 4' -4"
PAINT/PAINT
SAFETY GLAZING REQUIRED
1/42.0
B
BEDROOM 1
2
2' -9" x 4' -5"
PAINT/PAINT
I /A2.0
C
BEDROOM I
4
2' -9" x 4' -5"
PAINT/PAINT
Y
1/42.0
D
BEDROOM 2
4
2' -3" x 4' -5"
PAINT/PAINT
Y
1/42.0
E
BEDROOM 2
2
2'-9" x 4' -5"
PAINT/PAINT
2/A2.0
F
LAUNDRY
3
2' -5" x 2' -8"
PAINT/PAINT
2/42.0
G
LIVING ROOM
3
4' -11" x 2' -10"
PAINT/PAINT
2/42.0
I-1
LIVING ROOM
3
5' -10" x 3' -9"
PAINT/PAINT
2/A2.0
(E) = EXISTING
NOTE: SURPLUS ALL EXISTING VINYL WINDOWS TO HOMEOWNER
(E) CEMENTI1IOUS SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) CEMENTITIOUS AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF - ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE HELD DETERMINED
BACKER ROD 4 SEALANT
u
ACOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) WALL UNDERLAYMENT
WnW
WINDOW HEAD
CAREFULLY CUT BACK CEMENTITIOUS SIDING TO
ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT
(E) WALL UNDERPAYMENT AND INSTALL SELF
ADHERING MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OVER NAILING FLANGE
AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK,
TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY
CRACKS WHICH DEVELOP IN SIDING FROM
INSTALLATION OF FLASHING
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FN
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE CEMENTITIOUS
SIDING FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) CEMENTITIOUS SIDING
(E) WALL UNDERLAYMENT
(E) IUD. PANELING
(E) EXTERIOR SHEATHING
SELF - ADHERING MEMBRANE
CUT (E) WD. PANELING
AS REQUIRED. REPLACE
AND MATCH (E) PANELS
AND TRIM WHERE
DAMAGED DURING
CONSTR
SEALANT 4 BACKER ROD
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
TRIM- MATCH (E) TRIM.
PRIME ALL SIDES AND
PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD
DETERMINED
WINDOW JAMB
CUT (E) WO. PANELING AS
REQUIRED. REPLACE AND
MATCH (E) PANELS AND
TRIM WHERE DAMAGED
DURING CONSTR
WINDOW SILL
BACKER ROD 4
SEALANT
3/4" WD. SILL - STAIN TO
MATCH (E)
CUT (E) UJD. PANELING
AS REQUIRED. REPLACE
AND MATCH (E) PANELS
AND TRIM WHERE
DAMAGED DURING
CONSTR.
SELF- ADHERING
MEMBRANE
(E) WD. PANELING
CEMENTITIOUS SIDING - WINDOW DETAIL SET
3 "= 1' -0"
(E) WO. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF WINDOW
ASSEMBLY 4 FLASHING. REPLACE W/
NEW SIDING 4 PAINT TO MATCH (E)
SIDING
PRE- PRIMED, GALV SHEET METAL FLASHING
UNDER SELF- ADHERING MEMBRANE. COLOR
t0 BE SELECTED IN THE FIELD
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
(E)GI11B
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
SELF ADHERING
MEMBRANE
WOOD TRIM TO MATCH
E), PAINT/STAIN TO
MATCH (E) TRIM
ACOUSTICAL WINDOW ASSEMBLY
CAREFULLY CUT BACK (E) WP. SIDING
TO ALLOW FOR REATTACHMENT TO R.O.
FRAMING. LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF ADHERING
MEMBRANE WINDOW NAILING FLANGE
AGAINST SHEATHING. INSTALL SECOND
LAYER OF SELF ADHERING MEMBRANE
OVER NAILING FLANGE AND LAP UNDER
(E) WALL UNDERLAYMENT. CAULK, TOOL
FLUSH, AND PANT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN
SIDING FROM INSTALLATION OF
FLASHING
(E) WD. SIDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
WD. JAMB LINING
SEALANT
II II III swim
� NECESSARY
WINDOW HEAD INSULATION
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
WINDOW NAILING FIN --��
TRIM- MATCH (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
CAREFULLY REMOVE (E) WOOD SIDING
FOR INSTALLATION OF WINDOW
ASSEMBLY AND TRIM. REPLACE W/ NEW
SIDING AS REQ'D TO MAINTAIN
COURSING 4 PAINT TO MATCH (E) SIDING
(E) EXTERIOR SHEATHING
(E) Up SIDING
O1 t
II II II
WINDOW JAMB
(E) GUJ8
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
WD JAMB LINING
SEALANT
SHIM AS NECESSARY
FILL GAP LW BATT
INSULATION
BACKER ROD 4
SEALANT
3/5"
3/4" IUP. SILL - STAIN TO
MATCH (E)
WINDOWSILL
WOOD SIDING - WINDOW DETAIL SET
3 " =1' -0"
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
SELF - ADHERING
MEMBRANE
(E) GU1B
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08500 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. HELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
711- 2"; 1
EX
ED
MAR 122012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City &fi T'ukwil a
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERM1TCENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
A,,HITECT
COTT +WTE� PE;
STATE OF r . HINGTON
0810.03.1832
2/24/11
0
a
J
Z
O
z
w
F-
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
5 -53 -0058 -043
z
0
z_
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1832
DOOR TYPES
A
FLUSH 5CW W/ WAGON
WHEEL AND 4 PANELS W/
SAFETY GLAZING W/
OBSERVATION PORT
FLUSH SCW
1 LITE W/
W/ SAFETY GLAZING
C
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
Wx H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
1
LIVING ROOM
A
2' -11" x 6' -S"
STAIN/STAIN
HW -I 1 616
DK -2
LOCK -I
1 /A2.1
2
LAUNDRY ROOM
B
2' -8" x 6' -S"
STAIN/STAIN
WW -1 1 616
DK -2
LOCK -I
2/42.1
3
LIVING ROOM
C
2' -11" x 6' -S"
1/42.1
4
LAUNDRY ROOM
c
2' -S" x 6' -S"
2/42.1
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08000 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE 70 8E TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
(E) CEMENTITIOUS SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF- ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP O
SELF - ADHERING MEMBRANE. TYP AT HEAD
AND JAMB
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF DOOR ASSEMBLY 1
TRIM. REPLACE W/ NEW SIDING 4 PAINT
t0 MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
SELF- ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
CAREFULLY CUT BACK (E) SIDING TO ALLOW
FOR. REATTACHMENT to RO. FRAMING. LIFT
(E) WALL UNDERLAYMENT AND INSTALL SELF
ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP N SIDING
FROM INSTALLATION OF FLASHING
(E) CEMENTITIOUS SIDING
DOOR HEAD
HARDWOOD TRIM TO MATCH
(E), PAINT /STAIN 10 MATCH
(E) TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATINER-
STRIPPING
DOOR PER SCHEDULE
CONTINUOUS SEALANT BEHIND
z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER - STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
OAK AND METAL THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
DOOR JAMB
DOOR SILL
(E) EXTERIOR SHEATHING
EXISTING FRAMING
HARDWOOD TRIM TO MATCH
(E), FAINT/STAIN TO MATCH
(E) TRIM
SWIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
CEMENTITIOUS SIDING - DOOR DETAIL SET
3 "= 1' -0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF - ADHERING
MEMBRANE AGAINST SHEATHING. LAP (E)
WALL UNDERLAYMENT OVER TOP OF
SELF- ADHERING MEMBRANE. TYF AT HEAD
AND JAMB
REMOVE (E) WOOD SIDING AS REQ'D
FOR INSTALLATION OF DOOR ASSEMBLY
4 TRIM. REPLACE W/ NEW SIDING 1 PANT
TO MATCH (E) SIDING
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED IN
THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
CAREFULLY CUT BACK (E) WD. SIDING TO
ALLOW FOR REATTACHMENT TO R.O. FRAMING.
LIFT (E) WALL UNDERLAYMENT AND INSTALL
SELF ADHERING MEMBRANE WINDOW NAILING
FLANGE AGAINST SHEATHING. INSTALL
SECOND LAYER OF SELF ADHERING
MEMBRANE OVER NAILING FLANGE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
TOOL FLUSH, AND PAINT FASTENER HEADS
AND ANY CRACKS WHICH DEVELOP IN SIDING
FROM INSTALLATION OF FLASHING
(E) WOOD SIDING
4
II
II
SELF- ADHERING
MEMBRANE
(E) EXTERIOR SHEATHING
Wool, TRIM TO MATCH (E),
PAINT /STAIN To MATCH (E)
TRIM
DOOR HEAD
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
HARDWOOD JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MIN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
DOOR JAMB
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
(E) EXTERIOR SHEATHING
EXISTING FLOOR STRUCTURE
DOOR SILL
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
WOOD SIDING - DOOR DETAIL SET
3" =1' -0"
EX
ED
MAR 1 22012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (208) 824 -2973
REGISTERED
�= 'HITE:CT
1,11106
COTT T.EMPE;
STATE OF .5HGNGTO i
0810.03.1832
2/24/11
0
ce
a
-J
z
O
z
w
z
z
0
v
0
z
MPROVEMENTS
D
ce
W
W
W
0
ce
z
Z
AIP NUMBER
5 -53 -0058 -043
z
0
F-
0
z
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1832
(E) BACKER BOARD
(E) VINYL SIDING
BACKER BOARD
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL TOP EDGE OF SELF ADHERING
MEMBRANE AGAINST SHEATHING. LAP OVER
METAL FLASHING MD EXTEND SELF
ADI.4ERING MEMBRANE 4" UP WALL FROM TOP
OF FLASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF SELF ADHERING MEMBRANE
REMOVE (E) VINYL SIDING AS REQ'D FOR
INSTALLATION OF VENT FIXTURE 4
FLASHING. REPLACE W/ NEW SIDING,
ACCESSORIES, 4 BLOCKING TO MATCH (E).
PRE- PRIMED, GALV SHEET METAL •Y'- '
UNDER SELF- ADHERING MEMBRANE. COLOR
TO BE SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COtIPOUND. 5ET IN MASTIC AT
EXTERIOR TRIM.
REPLACEMENT SIDING AS REQUIRED
SHIM BACKER BOARD AS
REQUIRED
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
(E) EXTERIOR SHEATHING
2X2 BLOCKING, 4 SIDES
(PT.)
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
EXISTING VENT COVER
EXISTING ROOF
STRUCTURE
NEW 2 "X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2"X SPACER
LATERAL SECTION
6" MIN. TYPICAL TOP 4
BOTTOM
NEW 1" INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
ROOF VENT BAFFLE DETAIL
1 1/2" = 1' - 0"
EXISTING ROOF
(E) ROOF FRAMING
(E) SOFFIT VENTS
INSULATION DAM DETAIL
3 "= 1' -0"
INSULATION
INSULATION DAM
(E) WALL FRAMING
BLENDING UNIT ATTACHMENT
11/2 " =1' -0"
EXIST. WALL
CONSTR
(2) SIMPSON A -34
• EACH SIDE PANEL
OPEN TOP
EXIST. GABLE
VENT
NEW #" GALV.
HARDWARE
CLOTH
LS
" CDX PLYWOOD
AT (3) SIDES
1" OWENS CORNING 'x"103
INSULATION, TYPICAL.
SECURE WITH PIN TYPE
FASTENERS TO PLYWOOD
BACK MD SIDE PANEL
NOTE:
1 AFTER FABRICATION, BAFFLE SHALL BE SECURELY
ATTACHED IN POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OPENING.
GABLE VENT BAFFLE DETAIL
1 1/2" = 1' - 0"
SUSPEND MECH UNIT FROM (E)
STRUCTURE RE: MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
MAR 1 2. 2012
D
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A ,HITECT
;. COTT
-STATE OF
0810.03.1832
2/24/11
TEMP
HINGTON
O
0_
0 ›-
Z W M
O W
Z W
c
w p
z
Z �
L.L
Z U
O
U <
(7
Z Q
w
0
CO
W
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
0
Z
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1832
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT JAMBS
AND HEAD
BUTTERFLY
CORNERS, TYP.
NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
12"
LAP SILL MEMBRANE
FLASHING 1 -1/2" OVER
(E) BLDG. PAPER AT
SILL. EXTEND I in
BEYOND RA. AT EA.
END OF SILL.
(E) BLDG.
PAPER AT
SILL
(E) SHEATHING
CUT SILL
FLASHING 4 FOLD
THROUGH RO. AS
SHOWN.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE
OF WALL
SHEATHING
i" MIN
15UTTEi LY CORNER FLASHING
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATHING AT
JAMBS AND HEAD.
(E) SIDING NOT
SHOWN FOR CLARITY.
NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
WINDOW NAIL FLANGE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE COMPLETE
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW OUT
BEYOND EDGE OF
WINDOW FLANGE AND
SHOULD FILL FLANGE
NAIL I4OLES. REMOVE
EXCESS MATERIAL.
DO NOT SEAL FLANGE
AT WINDOW SILL
(E) BLDG. PAPER
AT SILL.
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT 5HOW■
FOR CLARITY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
1
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 514O1LN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
0
3' TYP.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 51-1T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
TRIMMED EDGE
OF (E) SIDING,
51401LN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
ALLOW I /8" CLEARANCE
BETWEEN FLASHING AND
150T. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND
oR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
r
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
MAR .122012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
4220
REGISTERED
A;'HITECT
0810.03.1832
TEMPE
7SHINGTON
2/24/11
0
II
Ice
.r�
J
z
0
z
ct
w
1—
z
1--
z
0
U
0
z
CJ)
z
w
w
0
0
0
w
2
w
w
0
z
L.L
J
ce
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1832
0
0
o,
0
0
0
o
0 0 0
MEMBRANE
FLASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
BEND
ANCHORAGE
NAILS DOWN
OVER NAIL
FLANGE, HEAD
ONLY.
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS.
NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
REMOVED
EDGE OF (E)
SIDING, SHOWN
DIAGRAMATICALLY.
(E) SIDING
NOT 5HOW■
FOR CLARITY.
(E) SHEATHING
NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
LAY (E) BLDG
PAPER BACK
DOWN OVER
FLANGE
FLASHING AT
JAMBS
1
WHERE REQUIRED, TRIM
(E) BLDG PAPER AT
HEAD TO PREPARE
FOR INSTALLATION OF
HEAD FLASHING AND
WINDOW TRIM
(FOLLOWING STEPS).
L
HEAD FLASHING PREPARATION
SCALE: NTS
(E) BLDG. PAPER
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT 514O1LN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
CUT JAMB FLASHING 4
FOLD AROUND WINDOW
OPENING AS SHOWN.
EXTEND 1 -1/2" BEYOND
EDGE OF OPENING AT
HEAD, JAMBS, AND SILL.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
MEMBRANE FLASHING AT JAMB
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. A5 REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
0
3' TYP.
INSTALL SILL FLANGE FLASHING OVER WINDOW
NAIL FLANGE AND FLASHING.
INSTALL 51-1T. METAL
HEAD FLASHING
UNDER (E) BLDG
PAPER.
MEMBRANE FLASHING AT SILL
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
TRIMMED EDGE
OF (E) SIDING,
51401LN
DIAGRAMATICALLY.
(E) SIDING NOT
SHOWN FOR
CLARITY.
ALLOW I /8" CLEARANCE
BETWEEN FLASHING AND
150T. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE: NTS
(E) BLDG. PAPER
CUT HEAD
FLASHING 4 FOLD
AROUND WINDOW
OPENING AS
SHOWN. EXTEND
1 -1/2" BEYOND
RO. AT HEAD
AND JAMBS.
ADHERE
PENETRATION
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
(TYP. EACH SIDE
OF WALL)
MEMBRANE FLASHING AT HEAD
SCALE: NTS
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND
oR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
— INSTALL JAMB FLANGE FLASHING OVER WINDOW
NAILING FLANGE AND FLASHING.
MEMBRANE FLASHING AT JAMB
SCALE: NTS
INSTALL HEAD
FLANGE FLASHING
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
r
WOOD TRIM INSTALLATION
SCALE: NTS
INSTALL WD. TRIM. BUTT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETWEEN WINDOW
TRIM AND SIDING.
LEAVE i" GAP BETWEEN
WINDOW TRIM AND
WINDOW FRAME. INSTALL
CONT. BEAD OF
SEALANT AND BACKER
ROD IN GAP.
GENERAL NOTES:
1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF
ADHEARING MEMBRANE FLASHING" TYPICALLY
REFERED TO AS "PEEL AND STICK"
2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE
INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE,
SHIMMED, AND ANCHORED.
4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD
FLASHING.
5: DETAILS 10 REFER TO WOOD TRIM AND CAULK
JOINTS.
NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D
(E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
J
WINDOW FLASHING INSTALLATION
SCALE: NTS
MAR .122012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
4220
REGISTERED
A;'HITECT
0810.03.1832
TEMPE
7SHINGTON
2/24/11
0
II
Ice
.r�
J
z
0
z
ct
w
1—
z
1--
z
0
U
0
z
CJ)
z
w
w
0
0
0
w
2
w
w
0
z
L.L
J
ce
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
FLASHING
DETAILS
A2.3
0810.03.1832
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTU H
CD
CFM
CI RC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
XX
OR ZX
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
X/Y
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
SG
+ r +
1><I
-el- 0-1-
CI 0 R
EQUIP ID �._
#
x
NG
I ■I
•
3
0
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP
VD
RA /EA
RG
SA
SA
RA /EA
SD
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
<.08" WG
8"
8"
CEILING
DECO
1, 2, 3
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1832
802
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION 1 MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
EX
MAR 1 2 2012
D
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) 4a
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION ].
QF = 45 / (1 X 1/2) = 90 CFM
RECEIVED
JUL 19 2011
PERMITCENTER
SEPARATE
PERMIT AND D
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional United liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(206) 624 -2777 • FAX (2o11) 1124 -2078
THE GREENBUSCH GROUP, )NC
A VIDEO & YEOVSKOL ENONEERING
ta1111 tEVT me SINN 20111 201 ISNIIX at gm
(206) 378 -0389 (206) 378 -0041 FAX
0810.03.1832
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1832
SEE
4.0=1
90
SEE
ISEDROOM
2
TYP ALL
CEILING GRILLES
TYP
RG -1
25
BATI -I
4 "0
25
7 "0 BEDROOM
TYP
LAUNDRY
ROOM
4 "0
SEE
7 "0
u-)
KITGNEN
LIVING
ROOM
SG -1
140
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
ATTIC
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE
ACCESS
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
2. HEATING IS PROVIDED BY ELECTRIC
BASEBOARD HEATERS.
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN ATTIC. USE
EXISTING ATTIC ACCESS HATCH FOR
MAINTENANCE AND ELECTRICAL ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
DUCT PER PLAN
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1 /A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
\)\\ 73\
DUCT PER PLAN
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
�CEILING GRILLE INSTALLATION DETAIL
NONE
EXPI
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
MAR 1 2. 2012
D
RECEIVED
JUL 1 9 2011
PERMJTCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A, Professional Limited Liability company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98108
(206) 624 -2777 • FAX (206) 624-2073
THE GREENBUSCH GROUP, INC
•• • • • VI • 111)))
16 MST 166M1011 SIFT NIX 201 216114 161 611110
(206) 378-0560 (206) 379 -0641 FAX
0810.03.1832
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
ISSUED
02/24/11
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1832
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM do AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE COMPLETE POWER AND CONTROL CONNEC110N FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
O HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE
DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE
ATTIC.
PANEL
MP
LOCATION:
SERVING:
0810.03.1 832
SYMBOL
10,000
120/240 VOLT, 1 PHASE, 3 WIRE.
DESCRIPTION
RESIDENCE
AIC,
200 AMP with MAIN BKR
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
m
III
BRANCH CIRCUIT 1MRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
CKT
LOAD DESCRIPTION
TYPE
KVA
AIP
PHASE A/P
KVA
TYPE
LOAD DESCRIPTION
CKT
1
EXISTING LOAD
BRANCH CIRCUIT HOME RUN
CO
40/2
4012
ELECTRICAL METER
EXISTING LOAD
2
3
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
TIMER OPERATED SWITCH
— - —
B
Q
THERMOSTAT
4
5
EXISTING LOAD
3012
A
2012
EXISTING LOAD
6
7
6
8
9
EXISTING LOAD
2012
A
6012
EXISTING LOAD
10
11
B
12
13
EXISTING LOAD
20/2
A
■
2011
EXISTING LOAD
14
15
6
2011
EXISTING LOAD
16
17
EXISTING LOAD
15/1
A
2011
EXISTING LOAD
18
19
EXISTING LOAD
1511
B 20/1
EXISTING LOAD
20
21
EXISTING LOAD
16/1
A
2011
BLENDING UNIT
22
23
EXISTING LOAD
3011
B 2011
SMOKE DETECTS
24
25
A
26
27
6
28
29
A
30
PHASE LOAD PHASE Az
KVA PHASE B�
KVA
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS
MAIN BKR SHUNTTRIP ❑ PANEL SKIRTS ❑ SURFACE
•
0 RAINTIGHT NEMA -3R ENCLOSURE [] DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL l INTEGRAL
FLUSH
TVSS I♦
REMARKS:
15/1
�1 BLACK
L -0 0
N WHITE
BLACK
WHITE
RED
BLACK
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE 1
RED
1 EC1ANICAL ! ELECTRICAL Coo ,D INATIoN
ITEM
N0.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
BV -1
15
16
15
NSTALLED
UNDER DIVISION
16
BLENDING UNIT VENTILATOR
120
1
X
N/A
WIRED
UNDER DIVISION
15
16
SWITCHES (ON, TIMER)
120
1
X
X
X
X
N/A
REMARKS
1,2
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
PROVIDE NEW S.E. RATED
PANEL BOARD. INTERCEPT
AND EXTEND EXISTING
CIRCUITS AND CONNECT TO
NEW BREAKERS.
DEMO EXISTING ELECTRICAL
PANEL. USE AS JUNCTION
BOX. EXTEND EXISTING
CIRCUITS TO NEW PANEL
LAI�NDi1'
ROOM
KITONEN
L IvING
ROOM
MP /22
MAIN FLOOR PLAN
1/4" = 1'
MAR 1 2 2012
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1832
O
0
J
Z/
L.L
w
z
Z
0
0
0
MPROVEMENTS
0
w
2
w
w
(/)
O
z
u_
0
J
•
Z
w
0
L.L
AIP NUMBER
5 -53- 0058 -043
Z
0
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1832
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
m
III
BRANCH CIRCUIT 1MRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
11
4
DAMPER CONNECTION
0'
NON -FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
CO
FIRE ALARM SMOKE DETECTOR 120V OPERATED
ELECTRICAL METER
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
TIMER OPERATED SWITCH
— - —
Q
THERMOSTAT
1 EC1ANICAL ! ELECTRICAL Coo ,D INATIoN
ITEM
N0.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
BV -1
15
16
15
NSTALLED
UNDER DIVISION
16
BLENDING UNIT VENTILATOR
120
1
X
N/A
WIRED
UNDER DIVISION
15
16
SWITCHES (ON, TIMER)
120
1
X
X
X
X
N/A
REMARKS
1,2
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
PROVIDE NEW S.E. RATED
PANEL BOARD. INTERCEPT
AND EXTEND EXISTING
CIRCUITS AND CONNECT TO
NEW BREAKERS.
DEMO EXISTING ELECTRICAL
PANEL. USE AS JUNCTION
BOX. EXTEND EXISTING
CIRCUITS TO NEW PANEL
LAI�NDi1'
ROOM
KITONEN
L IvING
ROOM
MP /22
MAIN FLOOR PLAN
1/4" = 1'
MAR 1 2 2012
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1832
O
0
J
Z/
L.L
w
z
Z
0
0
0
MPROVEMENTS
0
w
2
w
w
(/)
O
z
u_
0
J
•
Z
w
0
L.L
AIP NUMBER
5 -53- 0058 -043
Z
0
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1832