Loading...
HomeMy WebLinkAboutPermit D11-231 - ENYEART RESIDENCE - UPGRADESENYEART RESIDENCE 11818 44 AV S EXPIRED 03 -12 -12 D11 -231 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400985 Address: 11818 44 AV S TUICW Suite No: Project Name: ENYEART RESIDENCE DEVELOPMENT PERMIT Permit Number: D11 -231 Issue Date: 09/14/2011 Permit Expires On: 03/12/2012 Owner: Name: ENYEART JADANNE L Address: 30118 27TH S , FEDERAL WAY WA 98003 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $17,932.00 Fees Collected: $716.64 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11-231 Printed: 09 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: I hereby certify that I have read an ex governing this work will be compli d wit The granting of this permit does not . es construction or the performance of wor ernut. to this p Signature: Public: Non - Profit: N Public: Date: 091Iwlli ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development permit and agree to the conditions attached Print Name: Date: 7 //q/0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-231 Printed: 09 -14 -2011 this requirement. • 0 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Thkwila Building Department (206- 431 - 3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -231 Printed: 09 -14 -2011 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Asoft Building Permit No. Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) 1 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 11818 44th Ave. S. Tenant Name: Jadanne L. Enyeart Property Owners Name: Jadanne L. Enyeart Mailing Address: 11818 44th Ave. S. King Co Assessor's Tax No.: 3347400985 Suite Number: Floor: New Tenant: ❑ Yes Tukwila WA City State No 98178 Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFOR1L ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 1 7,932 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 10.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None El Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15` Floor 745 2nd Floor 3'd Floor Floors thru ' Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None El Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. HAApplications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised. 1 -2009 bh Page 2 of 6 PLUMBING AND GAS PIPIN "ERMIT INFORMATION - 206-431 1 70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms- Applications On- Line\2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 oW I PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A ED - NT: Print Name: Ti • •thy J. Fenla J • , SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777 Signature: Date: Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 City State Zip IDate Application Accepted: `1-(9- ( ( Date Application Expires: Staff Initials: H. \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 CitOof Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http : //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011 RECEIPT NO: R11 -01600 Initials: WER Payment Date: 07/28/2011 User ID: 1655 Total Payment: 13,064.48 Payee: PAMELA K KUEHL SET ID: 071911 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D11 -222 748.15 D11 -223 716.64 D11 -224 1,092.10 D11 -225 993.76 D11 -226 622.10 D11 -227 653.61 D11 -228 1,067.51 D11 -229 685.13 D11 -230 685.13 D11 -231 716.64 D11 -232 1,018.34 D11 -233 559.07 D11 -234 811.18 D11 -235 1,042.93 D11 -236 1,652.19 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,064.48 TOTAL: 13,064.48 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 7,876.95 000.345.830 5,120.03 640.237.114 67.50 TOTAL: 13,064.48 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D11 -231 ENYEART RESIDENCE 1181844 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 03/12/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer Marshall it Technician File: Permit File No. D11 -231 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 40 GOP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -231 DATE: 07- 19 -11. PROJECT NAME: ENYEAKIvRESIDENCE SITE ADDRESS: 11818 44 AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit. Issued DEPARTMENTS: ET AwC uTding Division °1' Public Works NIA- in - iF re Prevention Structural 1. QV— Or 01.24.i Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07 -21 -1 1 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-18-11 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 • 1 General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135245 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M 5- 53- 0058 -043 SEPARATE. PERMIT REQUIRED FOR: (Mechanical electrical Plumbing Was Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT": Revisions will require a new plan submittal and may Include additional plan review fees. FIL COPY Permit No. . )„4 l Phri r vIew approval is sublat to errors and omissions. t roval of construction documents does not authorize I olation of any adopted code or =finance. Receipt of approved Field +`i is acknowledged: By /! i Date: City Of Tltkwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG o 3 2011 A)S City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, international Fire Code, international Mechanical Code ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Chance) V 5 NON SPRINKLERED 3341400985 LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV • 1 W 140 FT OF FOLD 3 AND N 30 FT OF 4 BUILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: MAR .1 2. 2012 DRAWING INDEX T0.0 41.0 42.0 A2.1 42.2 42.3 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE 4 DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County international Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E-mail: &harynParlcereklngcounty .gov ARCHITECT: S,M. &temper Architects PLL.C. 4000 Delrldge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryesmstemper.com melodyasmstemper.com tlmeemstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839 0819 Fax: 206.839.0824 Contact:. Mohamed Alt Allaoua E -mail: mohamedassaacoustics.com MECHANICAL ENGINEER: The Greerbusch Group 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 315. 0569 Fax: 206.318.0641 Contact: Chris Ager E -mail: Chr1sAegreenbuschcom ELECTRICAL ENGINEER Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcratreswest.com REGULATED MATERIALS: P8S Engineering and Environmental 2511 Eastlake Ave. Ey Suite 100 Seattle, WA 98102 Ph 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenapbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. +'200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornell E -mail: JCornwellaJonespayne.com ECEIVED JUL 19 2011 P4`l,R�'V�E f TCTR b 11-9 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 REGISTERED. bill'' .,Con # TEMPE• SATE .O f 11!NGTDN .. 0810.03.1832 2/24111 i-- 0 aC —J z z w z' z 0 0 z MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 z 0 z 1— LJJ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1832 PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT 15 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES I. CONTRACTOR TO PROTECT GONERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. I- IMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 0:00 AM EACH DAY. I4CMEOWNERS WILL HAVE COMPLETE ACCESS TO TI4E RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN S:00 AM AND 5:00 P11. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. '3. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS I- IATCI -{E5. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SWEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POUER OUTAGE I5 EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M. I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11 CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 13 EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. CLOSET BEDROOM BATH 1- w N 0 1) LAUNDRY ROOM 11 NEW ELECTRICAL PANEL KITCHEN (E) STOVE 24" x 24" EXIST. ATTIC ACCESS PANEL LIVING ROOM MAIN FLOOR PLAN 1 /4" = 1' 0 A. EAST ELEVATION B. SOUTH ELEVATION PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0 ODEMOLISH EXISTING DOOR(5), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET A2.I OBLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC,REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 5/A2.2 FOR DETAIL. ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I /422 FOR DETAIL. COORDINATE WITH MECHANICAL. OINSTALL VENT BAFFLE(5) AT EXISTING GABLE END VENT(S) IN ATTIC, REF. 3/422 FOR DETAIL. OINSTALL VENT BAFFLE(5) AT EXISTING RIDGE VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL. IDCOORDINATE CEILING GRILL WITH MECHANICAL. OSURPLUS BOTH (E) LIVING ROOM AND LAUNDRY ROOM DOORS TO HOMEOWNER OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. NE CONTRACTOR MD THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 16'-5" 3' -10" E r r I1 J I -RAISE INSULATION - - CU IC4EIGWT AT . . EXLS . ,14Ttic ?ICCES P LI. �r ri - 24" x 24" EXIST. ATTIC ACCESS PANEL 1 1 IA J I L_ i r L dl v ATTIC PLAN 1/4" = 1' MAR .1 22012 L C. WEST ELEVATION pl\ D. NORTH ELEVATION LEGEND r J _.._.__ ACOUSTICAL WINDOW -�- I NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE • IGAS NOT USED NOT USED REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 arm INSULATIOI ERMIT CENTER INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED GAS METER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED A ''HITECT 0810.03.1832 TEMP SHINGTON • 2/24/11 NTERNATIONAL AIRPORT KING COUNTY MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN A A, LB &J H FLOOR PLANS NOTES A1.0 0810.03.1832 WINDOW TYPES 18" MIN. SINGLE HUNG/ FIXED /SINGLE HUNG 2 SINGLE HUNG 3 SLIDER 4 CASEMENT WINDOW SCHEDULE 1 ROOM WIND. f TRIM FINISH f EGRESS DETAIL SINGLE HUNG/ FIXED /SINGLE HUNG 2 SINGLE HUNG 3 SLIDER 4 CASEMENT WINDOW SCHEDULE WIND. ROOM WIND. SIZE TRIM FINISH REMARKS EGRESS DETAIL NO LOCATION TYPE W x H INT./ EXT. SET A LIVING ROOM I 6' -0" x 4' -4" PAINT/PAINT SAFETY GLAZING REQUIRED 1/42.0 B BEDROOM 1 2 2' -9" x 4' -5" PAINT/PAINT I /A2.0 C BEDROOM I 4 2' -9" x 4' -5" PAINT/PAINT Y 1/42.0 D BEDROOM 2 4 2' -3" x 4' -5" PAINT/PAINT Y 1/42.0 E BEDROOM 2 2 2'-9" x 4' -5" PAINT/PAINT 2/A2.0 F LAUNDRY 3 2' -5" x 2' -8" PAINT/PAINT 2/42.0 G LIVING ROOM 3 4' -11" x 2' -10" PAINT/PAINT 2/42.0 I-1 LIVING ROOM 3 5' -10" x 3' -9" PAINT/PAINT 2/A2.0 (E) = EXISTING NOTE: SURPLUS ALL EXISTING VINYL WINDOWS TO HOMEOWNER (E) CEMENTI1IOUS SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) CEMENTITIOUS AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE HELD DETERMINED BACKER ROD 4 SEALANT u ACOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) WALL UNDERLAYMENT WnW WINDOW HEAD CAREFULLY CUT BACK CEMENTITIOUS SIDING TO ALLOW FOR REATTACHMENT TO RA. FRAMING. LIFT (E) WALL UNDERPAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FN TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE CEMENTITIOUS SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) CEMENTITIOUS SIDING (E) WALL UNDERLAYMENT (E) IUD. PANELING (E) EXTERIOR SHEATHING SELF - ADHERING MEMBRANE CUT (E) WD. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR SEALANT 4 BACKER ROD SHIM AS NECESSARY FILL GAP W/ BATT INSULATION TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED WINDOW JAMB CUT (E) WO. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR WINDOW SILL BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) CUT (E) UJD. PANELING AS REQUIRED. REPLACE AND MATCH (E) PANELS AND TRIM WHERE DAMAGED DURING CONSTR. SELF- ADHERING MEMBRANE (E) WD. PANELING CEMENTITIOUS SIDING - WINDOW DETAIL SET 3 "= 1' -0" (E) WO. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR t0 BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED BACKER ROD 4 SEALANT (E)GI11B (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WOOD TRIM TO MATCH E), PAINT/STAIN TO MATCH (E) TRIM ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WP. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PANT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT WD. JAMB LINING SEALANT II II III swim � NECESSARY WINDOW HEAD INSULATION ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FIN --�� TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WINDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCH (E) SIDING (E) EXTERIOR SHEATHING (E) Up SIDING O1 t II II II WINDOW JAMB (E) GUJ8 WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM WD JAMB LINING SEALANT SHIM AS NECESSARY FILL GAP LW BATT INSULATION BACKER ROD 4 SEALANT 3/5" 3/4" IUP. SILL - STAIN TO MATCH (E) WINDOWSILL WOOD SIDING - WINDOW DETAIL SET 3 " =1' -0" WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SELF - ADHERING MEMBRANE (E) GU1B TYPICAL WINDOW SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08500 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. HELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 711- 2"; 1 EX ED MAR 122012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City &fi T'ukwil a BUILDING DIVISION RECEIVED JUL 19 2011 PERM1TCENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A,,HITECT COTT +WTE� PE; STATE OF r . HINGTON 0810.03.1832 2/24/11 0 a J Z O z w F- z z 0 U 0 z AIP NUMBER MPROVEMENTS 5 -53 -0058 -043 z 0 z_ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1832 DOOR TYPES A FLUSH 5CW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT FLUSH SCW 1 LITE W/ W/ SAFETY GLAZING C EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING ROOM A 2' -11" x 6' -S" STAIN/STAIN HW -I 1 616 DK -2 LOCK -I 1 /A2.1 2 LAUNDRY ROOM B 2' -8" x 6' -S" STAIN/STAIN WW -1 1 616 DK -2 LOCK -I 2/42.1 3 LIVING ROOM C 2' -11" x 6' -S" 1/42.1 4 LAUNDRY ROOM c 2' -S" x 6' -S" 2/42.1 TYPICAL DOOR SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08000 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE 70 8E TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. (E) CEMENTITIOUS SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP O SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 1 TRIM. REPLACE W/ NEW SIDING 4 PAINT t0 MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY CUT BACK (E) SIDING TO ALLOW FOR. REATTACHMENT to RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP N SIDING FROM INSTALLATION OF FLASHING (E) CEMENTITIOUS SIDING DOOR HEAD HARDWOOD TRIM TO MATCH (E), PAINT /STAIN 10 MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATINER- STRIPPING DOOR PER SCHEDULE CONTINUOUS SEALANT BEHIND z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER - STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL (E) EXTERIOR SHEATHING EXISTING FRAMING HARDWOOD TRIM TO MATCH (E), FAINT/STAIN TO MATCH (E) TRIM SWIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE CEMENTITIOUS SIDING - DOOR DETAIL SET 3 "= 1' -0" (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF - ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYF AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING 1 PANT TO MATCH (E) SIDING PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO R.O. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING 4 II II SELF- ADHERING MEMBRANE (E) EXTERIOR SHEATHING Wool, TRIM TO MATCH (E), PAINT /STAIN To MATCH (E) TRIM DOOR HEAD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING HARDWOOD JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE (E) EXTERIOR SHEATHING EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE WOOD SIDING - DOOR DETAIL SET 3" =1' -0" EX ED MAR 1 22012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (208) 824 -2973 REGISTERED �= 'HITE:CT 1,11106 COTT T.EMPE; STATE OF .5HGNGTO i 0810.03.1832 2/24/11 0 ce a -J z O z w z z 0 v 0 z MPROVEMENTS D ce W W W 0 ce z Z AIP NUMBER 5 -53 -0058 -043 z 0 F- 0 z DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1832 (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING MD EXTEND SELF ADI.4ERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PRE- PRIMED, GALV SHEET METAL •Y'- ' UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COtIPOUND. 5ET IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (PT.) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2"X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1 1/2" = 1' - 0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 "= 1' -0" INSULATION INSULATION DAM (E) WALL FRAMING BLENDING UNIT ATTACHMENT 11/2 " =1' -0" EXIST. WALL CONSTR (2) SIMPSON A -34 • EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW #" GALV. HARDWARE CLOTH LS " CDX PLYWOOD AT (3) SIDES 1" OWENS CORNING 'x"103 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK MD SIDE PANEL NOTE: 1 AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. GABLE VENT BAFFLE DETAIL 1 1/2" = 1' - 0" SUSPEND MECH UNIT FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL MAR 1 2. 2012 D REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED A ,HITECT ;. COTT -STATE OF 0810.03.1832 2/24/11 TEMP HINGTON O 0_ 0 ›- Z W M O W Z W c w p z Z � L.L Z U O U < (7 Z Q w 0 CO W MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 0 Z DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1832 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I in BEYOND RA. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING i" MIN 15UTTEi LY CORNER FLASHING MEMBRANE FLASHING AT SILL SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING SACK FROM (E) R.O. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL I4OLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT 5HOW■ FOR CLARITY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS 1 WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). L HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 514O1LN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 0 3' TYP. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL 51-1T. METAL HEAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. TRIMMED EDGE OF (E) SIDING, 51401LN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. ALLOW I /8" CLEARANCE BETWEEN FLASHING AND 150T. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND oR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING r WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. J WINDOW FLASHING INSTALLATION SCALE: NTS MAR .122012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 4220 REGISTERED A;'HITECT 0810.03.1832 TEMPE 7SHINGTON 2/24/11 0 II Ice .r� J z 0 z ct w 1— z 1-- z 0 U 0 z CJ) z w w 0 0 0 w 2 w w 0 z L.L J ce AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1832 0 0 o, 0 0 0 o 0 0 0 MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT 5HOW■ FOR CLARITY. (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RA. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS 1 WHERE REQUIRED, TRIM (E) BLDG PAPER AT HEAD TO PREPARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). L HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT 514O1LN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. A5 REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 0 3' TYP. INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. INSTALL 51-1T. METAL HEAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. TRIMMED EDGE OF (E) SIDING, 51401LN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. ALLOW I /8" CLEARANCE BETWEEN FLASHING AND 150T. EDGE OF (E) SIDING. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND 1 -1/2" BEYOND RO. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOtLN FOR CLARITY. REPLACE AND oR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB SCALE: NTS INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING r WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "1, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. J WINDOW FLASHING INSTALLATION SCALE: NTS MAR .122012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 4220 REGISTERED A;'HITECT 0810.03.1832 TEMPE 7SHINGTON 2/24/11 0 II Ice .r� J z 0 z ct w 1— z 1-- z 0 U 0 z CJ) z w w 0 0 0 w 2 w w 0 z L.L J ce AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1832 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU H CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX OR ZX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION X/Y EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL SG + r + 1><I -el- 0-1- CI 0 R EQUIP ID �._ # x NG I ■I • 3 0 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP VD RA /EA RG SA SA RA /EA SD DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" CEILING DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1832 802 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. EX MAR 1 2 2012 D THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 4a &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION ]. QF = 45 / (1 X 1/2) = 90 CFM RECEIVED JUL 19 2011 PERMITCENTER SEPARATE PERMIT AND D APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional United liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (2o11) 1124 -2078 THE GREENBUSCH GROUP, )NC A VIDEO & YEOVSKOL ENONEERING ta1111 tEVT me SINN 20111 201 ISNIIX at gm (206) 378 -0389 (206) 378 -0041 FAX 0810.03.1832 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1832 SEE 4.0=1 90 SEE ISEDROOM 2 TYP ALL CEILING GRILLES TYP RG -1 25 BATI -I 4 "0 25 7 "0 BEDROOM TYP LAUNDRY ROOM 4 "0 SEE 7 "0 u-) KITGNEN LIVING ROOM SG -1 140 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE ATTIC USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC BASEBOARD HEATERS. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN ATTIC. USE EXISTING ATTIC ACCESS HATCH FOR MAINTENANCE AND ELECTRICAL ACCESS. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE DUCT PER PLAN SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE \)\\ 73\ DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. �CEILING GRILLE INSTALLATION DETAIL NONE EXPI SEPARATE PERMIT AND APPROVAL REQUIRED MAR 1 2. 2012 D RECEIVED JUL 1 9 2011 PERMJTCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A, Professional Limited Liability company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (206) 624 -2777 • FAX (206) 624-2073 THE GREENBUSCH GROUP, INC •• • • • VI • 111))) 16 MST 166M1011 SIFT NIX 201 216114 161 611110 (206) 378-0560 (206) 379 -0641 FAX 0810.03.1832 RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE ISSUED 02/24/11 BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1832 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM do AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNEC110N FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. O HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. 0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. PANEL MP LOCATION: SERVING: 0810.03.1 832 SYMBOL 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. DESCRIPTION RESIDENCE AIC, 200 AMP with MAIN BKR G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. m III BRANCH CIRCUIT 1MRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. CKT LOAD DESCRIPTION TYPE KVA AIP PHASE A/P KVA TYPE LOAD DESCRIPTION CKT 1 EXISTING LOAD BRANCH CIRCUIT HOME RUN CO 40/2 4012 ELECTRICAL METER EXISTING LOAD 2 3 AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. TIMER OPERATED SWITCH — - — B Q THERMOSTAT 4 5 EXISTING LOAD 3012 A 2012 EXISTING LOAD 6 7 6 8 9 EXISTING LOAD 2012 A 6012 EXISTING LOAD 10 11 B 12 13 EXISTING LOAD 20/2 A ■ 2011 EXISTING LOAD 14 15 6 2011 EXISTING LOAD 16 17 EXISTING LOAD 15/1 A 2011 EXISTING LOAD 18 19 EXISTING LOAD 1511 B 20/1 EXISTING LOAD 20 21 EXISTING LOAD 16/1 A 2011 BLENDING UNIT 22 23 EXISTING LOAD 3011 B 2011 SMOKE DETECTS 24 25 A 26 27 6 28 29 A 30 PHASE LOAD PHASE Az KVA PHASE B� KVA LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS MAIN BKR SHUNTTRIP ❑ PANEL SKIRTS ❑ SURFACE • 0 RAINTIGHT NEMA -3R ENCLOSURE [] DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL l INTEGRAL FLUSH TVSS I♦ REMARKS: 15/1 �1 BLACK L -0 0 N WHITE BLACK WHITE RED BLACK WHITE SMOKE DETECTOR WIRING DIAGRAM NO SCALE 1 RED 1 EC1ANICAL ! ELECTRICAL Coo ,D INATIoN ITEM N0. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION BV -1 15 16 15 NSTALLED UNDER DIVISION 16 BLENDING UNIT VENTILATOR 120 1 X N/A WIRED UNDER DIVISION 15 16 SWITCHES (ON, TIMER) 120 1 X X X X N/A REMARKS 1,2 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH PROVIDE NEW S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONNECT TO NEW BREAKERS. DEMO EXISTING ELECTRICAL PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL LAI�NDi1' ROOM KITONEN L IvING ROOM MP /22 MAIN FLOOR PLAN 1/4" = 1' MAR 1 2 2012 RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1832 O 0 J Z/ L.L w z Z 0 0 0 MPROVEMENTS 0 w 2 w w (/) O z u_ 0 J • Z w 0 L.L AIP NUMBER 5 -53- 0058 -043 Z 0 DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1832 ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. m III BRANCH CIRCUIT 1MRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 11 4 DAMPER CONNECTION 0' NON -FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN CO FIRE ALARM SMOKE DETECTOR 120V OPERATED ELECTRICAL METER FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. TIMER OPERATED SWITCH — - — Q THERMOSTAT 1 EC1ANICAL ! ELECTRICAL Coo ,D INATIoN ITEM N0. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION BV -1 15 16 15 NSTALLED UNDER DIVISION 16 BLENDING UNIT VENTILATOR 120 1 X N/A WIRED UNDER DIVISION 15 16 SWITCHES (ON, TIMER) 120 1 X X X X N/A REMARKS 1,2 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH PROVIDE NEW S.E. RATED PANEL BOARD. INTERCEPT AND EXTEND EXISTING CIRCUITS AND CONNECT TO NEW BREAKERS. DEMO EXISTING ELECTRICAL PANEL. USE AS JUNCTION BOX. EXTEND EXISTING CIRCUITS TO NEW PANEL LAI�NDi1' ROOM KITONEN L IvING ROOM MP /22 MAIN FLOOR PLAN 1/4" = 1' MAR 1 2 2012 RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1832 O 0 J Z/ L.L w z Z 0 0 0 MPROVEMENTS 0 w 2 w w (/) O z u_ 0 J • Z w 0 L.L AIP NUMBER 5 -53- 0058 -043 Z 0 DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1832