Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-234 - MILLER RESIDENCE - UPGRADES
MILI.F,R RESIDENCE 11803 44 AV S EXPIRED 03 -12 -12 D11 -234 City Aukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400565 Address: 11803 44 AV S TUKW Suite No: Project Name: MILLER RESIDENCE DEVELOPMENT PERMIT Permit Number: D11 -234 Issue Date: 09/14/2011 Permit Expires On: 03/12/2012 Owner: Name: MILLER GARTH Z Address: 11803 44TH AVE S , TUKVVILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $20,710.00 Fees Collected: $811.18 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -234 Printed: 09 -14 -2011 Os • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: _ I 1 l I ►, ' II.: Date: 61111-qii I hereby certify that I have read an ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compli- • whether specified herein or not. The granting of this permit does not p : e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: S6 %F. 41A7t Date: /Aylti This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-234 Printed: 09 -14 -2011 this requirement. 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 011 -234 Printed: 09 -14 -2011 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.eLtukwila.wa.us Building Permit No. ,.,- Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 11803 44th Ave. S. King Co Assessor's Tax No.: 3347400565 Suite Number: Floor: Tenant Name: Garth Z. Miller New Tenant: ❑ Yes 0 .No Property Owners Name: Garth Z. Miller Mailing Address: 11803 44th Ave. S. Tukwila WA 98178 City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H \Applications\Porms- Applications On Line\2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFO ' _ION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 20,710 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 18t Floor 870 2nd Floor 3rd Floor Floors thru , Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 PLUMBING AND GAS PIPINCERMIT INFORMATION - 206 - 431"7 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications\Forms- Applications On-Line \2009 Applications \1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 AU IZED AGENT: Signature: Date: Print Name: Ti- othy J. Fenla , SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777 Mailing Address: 4000 Delridg'' ay SW, Suite 200 Seattle WA 98106 City State Zip Date Application Accepted: �` I 1` • ( Date Application Expires: v I c✓ �� Staff Initials: �,I, I H:\Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: t -2009 bh Page 6 of 6 Citipof Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 9 8188 Phone: 206 - 431 -3670 Fax: 20 6- 431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011 RECEIPT NO: R11 -01600 Initials: WER Payment Date: 07/28/2011 User ID: 1655 Total Payment: 13,064.48 Payee: PAMELA K KUEHL SET ID: 071911 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D11 -222 748.15 D11 -223 716.64 D11 -224 1,092.10 D11 -225 993.76 D11 -226 622.10 D11 -227 653.61 D11 -228 1,067.51 D11 -229 685.13 D11 -230 685.13 D11 -231 716.64 D11 -232 1,018.34 D11 -233 559.07 D11 -234 811.18 D11 -235 1,042.93 D11 -236 1,652.19 TOTAL: —148735-- TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,064.48 TOTAL: 13,064.48 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 7,876.95 000.345.830 5,120.03 640.237.114 67.50 TOTAL: 13, 064.48 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D11 -234 MILLER RESIDENCE 11803 44 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 03/12/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fifer Marshall it Technician File: Permit File No. D11 -234 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 PLAN TING SLIP r• ACTIVITY NUMBER: D11 -234 PROJECT NAME: MILLER RESIDENCE SITE ADDRESS: 11803 44 AV S X Original Plan Submittal Response to Incomplete Letter # DATE:.: 0749 -1`1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS:Q_1 C (T uilding n xce",„,golk■ RIP Fire Prevention Structural PFanning Divis0 n n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 07 -21 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route M Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -18-11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135245 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 Landmark American Ins Co LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.00 03/10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.0008 /05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - COO625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: ErMechanical ritlectrical Plumbing traas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be de to the scope c#,3.?ork without prior approval of ukwila Building Division. 1 NC—s. i : ;,,:sions will require n e a submittal w a :d r� Y include additional plan review FILE COPY Permit No. PIr t review approval is subject to errors and omisstons. /,;.;.)rovai of construction documents does not autho1ize :•oletion of any adopted code or ordinance. Receipt C cpproved Field C�p�a� Is acknowledged: City Of 'ilukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code 3341400% 7OW NG: SF 1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTRUCTION TYPE: (No Chance) V B NON SPRINKLERED LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV ' I 105 AND S 1/2 OF 106 5UILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: MAR 1 2 2012 DRAWING INDEX TO.0 TITLE SHEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS A2.1 DOOR TYPES, SCHEDULE 4 DETAILS A22 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS Ml. LEGENDS, SCHEDULES, ABBREV., GENERAL NOTES 4 DWG INDEX M2.0 MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS E1.0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206. 2%. 0190 Contact: Sharyn Parker E -mail: Sharyn.Parkere+kingcounty.gov ARCHITECT: SM. Stemper Architects PLL.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryesmetemper.com melodyesmstemper.com timeemstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 58109 Ph: 206. 539. 0519 Fax: 206.535.0524 ELECTRICAL ENGINEER Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98405 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Mohamed Alt Allaoua Contact: Brent Rollins E -mail: mohamedessaacoustica.com E -mail: bcretreswest.com MECHANICAL ENGINEER: The Greenbusch Group 1500 West Nickerson St., Suite 201 Seattle, WA 98115 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Chris Ager E -mail: C1risAegreenbuschcom REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E, Suite 100 Seattle, WA 98102 Ph: 206. 232. 5635 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenepbee nv.com DESIGN SUPPORT SERVICES Ths Jones Payne Group I23 North Washington St. *200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwelleionespayne.com VICINITY MAP (NTS) RECEIVED JUL 1: 9 2011 'ERMiC CENTEIs S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (20B) 824 -2973 COJT t.. TE,MPE S fATE OF , +SH NGTOM 2/24/11 0810.03.1835 i-- Ce 0 0 —J 0 ce H Z z 0 C.) 0 z H z w w 0 ce a 0 w w w 0 z I-- LL U Q AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1835 MAIN FLOOR PLAN 1/4" = 1' PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. NOTE: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081. r 13' -9" 23' -1" L. ■ L NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OIINERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE NE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, MD REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SWEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMIt1 POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 PM. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION Ii. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, MD WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. le. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. T T 1 ai -NEIU 24° x-24" ATTIC ACCESS-PANEL L RA -ISE INSULATION CURB HEIGHT -Al: ATTIC, ACES L - - - PANEL- L_ 19' -I0" BEDROOM 3 IT -0" �r v SECOND FLOOR PLAN/ ATTIC PLAN 1/4" = 1' A. EAST ELEVATION r L r T (E) S1Cl'L IGHTS r L (E) SKYLIGHT 0 Ilill11111111I J L B. SOUTH ELEVATION PLAN KEYNOTES cDDEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 42J OINSTALL SECONDARY SKYLIGHT UNDER (E) SKYLIGHT. MAXIMUM AIR SPACE BETWEEN SKYLIGHTS SHALL BE 4 ". VERIFY EXISTING CONDITIONS AND NOTIFY TECHNICAL REPRESENTATIVE IF EXISTING CONSTRUCTION DOES NOT ALLOW FOR THIS. REF. 6/A22 FOR DETAIL. OBLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED IN ATTIC REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 1/422 FOR DETAIL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. OINSTALL VENT 5AFFLE(5) AT EXISTING GABLE END VENT(5) IN ATTIC, REF. 3/422 FOR PETAL. OINSTALL VENT SAFFLE(S) AT EXISTING ROOF VENTS) IN Attic, REF. 4/A22 FOR DETAIL. OCOORDINATE CEILING GRILL WITH MECHANICAL. ONSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. 10 DEMOLISH EXISTING DOOR(S), INSTALL NEW INTERIOR DOOR REF. DOOR SCHEDULE ON SHEET A2.1. FLUSH SOLID CORE INTERIOR WOOD DOOR WITH TRIM PACKAGE 80114 ELEVATIONS, INCLUDE INTERIOR HARDWARE SET. II COORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL SE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. WEST ELEVATION r Q 1 J 11' -0" ATTIC PLAN 1/4" = 1' MAR 1 22012 D. NORTH ELEVATION LEGEND REVIEWED FOR COnF COMPLIANCE APPROVED j ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. 42.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE WALL VENT AUG 0 3 2011 City of Tukwila BUILDING DIVISI FEATHER TEXTURED CEILING OVER AT A 7'7'9MIN. OF 24" FROM EDGE OF PATCHING. MATCH (E) TEXTURE AND PAINT ATTIC ACCESS PANEL +— CEILING DEMOLITION FOR ATTIC PANEL q AND WHOLE HOUSE VENT INSTALLATION. • • REF. MECH. t ELECT. REF. GENERAL NOTE 11 ATTIC INSULATION RECEIVED JUL 19 2011 P Ag S`r'i sT CENTER SD INSTALL BATTERY OPERATED SMOKE DETECTORS 'GAS NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A HITECT , miff COTT IILTEMP STATE OF iASHINGTON' 0810.03.1835 2/24/11 i'- O a. J z O z W F- z z 0 0 z MPROVEMENTS ;r- a W W W C/) 0 z L.L U ©C 1- z AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1835 WINDOW TYPES SINGLE HUNG 2 FIXED 3 SLIDER f 4 SINGLE HUNG/ FIXED/ SINGLE HUNG B SLIDING SECONDARY SKYLIGHT 6 ALUMINUM REMOVEABLE SECONDARY WINDOW CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE WxH TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 4 T-10" x 4' -0" STAIN/PAINT I /42.0 B DINING ROOM 3 4' -10" x 3' -I0" STAIN/PAINT 1 /A2.0 C DINING ROOM 6 3' -10" x I' -8" STAIN/PAINT SAFETY GLAZING 2/42.0 D KITCHEN 1 2' -4" x 2' -I0" STAIN/PAINT 1/42.0 E BEDROOM I 3 2' -10" x 2' -10" STAIN/PAINT 1/42.0 BEDROOMI 1 (E) 2' -I0" x 2' -11 STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 46" Y I /42.0 BEDROOM 2 (E) 2' -I0" x 2' -11 STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 46" 1/42.0 14 BEDROOM 2 1 3' -I0" x 3' -10" STAIN/PAINT 1/42.0 KITCHEN SKYLIGHT 5 1' -8" x 3' -0" STAIN/PAINT SAFETY GLAZING 6/A22 J LIVING ROOM SKYLIGHT 5 4' -0" x 8' -0" STAIN/PAINT SAFETY GLAZING 6/A22 K BEDROOM 3 1 (E) 2' -10" x 2' -I0" STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT_ 45" Y I /42.0 L BEDROOM 3 3 3' -10" x 2' -10" STAIN/PAINT 1 /42.0 M BEDROOM 3 SKYLIGHT 5 2' -0" x 2' -0" STAIN/PAINT SLIDING SECONDARY SKYLIGHT, SAFETY GLAZING 6/42.2 (E) • EXISTING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING FLASHING 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING FLASHING REMOVE (E) VINYL SIDING AS R EQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 ACCESSORIES TO MATCH (E) PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD ACOUSTICAL WINDOW ASSEMBLY. (E) BACKER BOARD SOLID P.T. BLOCKING (E) EXTERIOR SHEATHING WINDOW HEAD (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), PANT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD PRE- PRIMED GALV. JAMB FLASHING LAP INTO SILL PAN FLASHING. EMBED LAP IN SEALANT. FIELD PAINT FLASHING - COLOR TO BE SELECTED IN THE FIELD CAREFULLY REMOVE (E) VINYL SIDING. CUT BACK (E) BACKER BOARD AND (E) VINYL SIDING FOR INSTALLATION OF SELF ADHERING MEMBRANE. INSTALL SOLID P.T. BLOCKING TO PROVIDE NAILING FOR BACKER BOARD. RE- INSTALL REPLACEMENT BACKER BOARD 4 (E) VINYL SIDING (E) EXTERIOR SHEATHING (E) BUILDING PAPER SILL PAN FLASHING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY SELF - ADHERING MEMBRANE ACOUSTICAL WINDOW ASSEMBLY. JAMB FLASHING SEALANT 4 BACKER ROD SILL VINYL UNDER SILL TRIM NEW BLOCKING 1111 11 WINDOW JAMB WD. JAMB LINING. FINISH TO MATCH (E) BACKER ROD SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM CAREFULLY REMOVE TOP COURSES OF (E) VINYL AND BACKER BOARD FOR INSTALLATION OF WINDOW ASSEMBLY 4 TRIM. REPLACE W/ NEW SIDING TO MATCH (E) (E) BACKER BOARD (E) VINYL SIDING WINDOW SILL VINYL SIDING - WINDOW DETAIL SET 3 "= 1' -0" SELF - ADHERING MEMBRANE LAP OVER (E) WALL UNDERLAYMENT 4 ". LAP SELF ADHERING MEMBRANE AT JAMBS OVER TOP OF SILL MEMBRANE EXTENSIONS (E) GWB (E) GWB HARDWOOD TRIM TO MATCH (E), PANT /STAIN TO MATCH (E) TRIM ALUMINUI SECONDARY WINDOW ASSEMBLY 3/4" WD. SILL - PAINT /STAIN TO MATCH (E) WINDOW HEAD (E) GLUE HARDWOOD TRIM TO MATCH (E), PANT /STAN TO MATCH (E) TRIM ALUMINUI SECONDARY WINDOW ASSEMBLY / 3/4" WD. SILL - PAINT /STAIN TO f MATCH (E) WINDOW JAMB WINDOW SILL (E) WINDOW ASSEMBLY ALUMINUM SECONDARY WINDOW ASSEMBLY 3/4" WD. SILL - PAINT /STAIN TO MATCH (E) HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM (E) GWI3 VINYL SIDING - WINDOW DETAIL SET 3 "= 1' -0" TYPICAL WINDOW SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. EX MAR 1 2 2012 ED REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED HITE:Ci /FP PA /' 0810.03.1835 2/24/11 O 0 J Q w O 2 Q � z w C LU z Ce z � z U O U < 0 Z z w 0 w ce MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z O z w DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1835 DOOR TYPES Alpf O El rA FLUSH SCW W/ RECTANGLE LITE AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT 13 FLUSH SCW W/ SIX PANELS INTERIOR C EXTERIOR SINGLE LEAF STOW W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I LIVING ROOM(w/ keypad entry) A 3' -0" x 6' -8" STAIN/STAIN 14111-1 / 605 DK -4 (Camelot) LOCK -2 I /A2.1 2 DINING ROOM (INTERIOR) B 2' 43" x 6' -8" STAIN/STAIN HW -I / 605 DK -3 (Neptune) NA I /A2.1 3 ENTRY C 3' -0" x 6' -S" I/A2.1 TYPICAL DOOR SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. STORM DOOR PER SCHEDULE oar a CAREFULLY LIFT (E) WALL UNDER LAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST 51-EATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL AS REQ'D FOR INSTALLATION OF DOOR ASSEMBLY I TRIM. REPLACE WI NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E) PRE - PRIMED FF GALV SHEET METAL FLASH( UNDER SELF - ADHERING MEMBRANE. EXTEND FLASHING 4" UP WALL DOOR HEAD WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FLL GAP W/ BATT INSULATION WDOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING POOR PER SCHEDULE CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE JAMB BEYOND (E) EXTERIOR SHEATHING (E) BACKER BOARD SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM 841M AS NECESSARY FLL GAP W/ BATT INSULATION HOOD FRAME KERF AS REQUIRED FOR HEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE WOOD DOOR PER SCHEDULE DOOR SHOE 2" MIN. AUTOMATIC DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE DOOR JAMB DOOR SILL VINYL SIDING - DOOR DETAIL SET 3 " =1' -0" L E ID MAR 1Z2012 2x CEILING FRAMING CONNECTED TO UNDER SIDE OF EXIST. TRUSS FRAMING W/ ONE LAYER, 5 /s" GWB, TAPED, FINISHED, PRIMED AND PANTED 2 COATS WOOD BLOCKING HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING p "V rp LKLEEZHN R TRppNG DOOR HEAD SHIM AS NECESSARY FILL GAP W/ BATT INSULATION BACKER ROD AND SEALANT HARDWOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM WOOD FRAME SURFACE APPLIED CONTINUOUS WEATHER STRIPPING KERF IN CONTINUOUS WEATHER STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE DOOR JAMB AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD EXISTING FLOOR STRUCTURE DOOR SILL INTERIOR - DOOR DETAIL SET HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM INTERIOR POOR PER SCHEDULE EXISTING FRAMING HARDWOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM DOOR PER SCHEDULE 3 "= 1' -0" REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED 'HITEICT ,1'I /F..: COTT '9 TEMPE.' STATE Q.; • 'SHINGTQN 0810.03.1835 2/24/11 O a J Z 0 w H z z 0 U 0 Z AIP NUMBER MPROVEMENTS 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1835 (E) BACKER BOARD (E) VINYL SIDING BACKER BOARD CAREFULLY LIFT (E) WALL UNDERLAYMENT MD INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP OVER METAL FLASHING AND EXTEND SELF ADHERING MEMBRANE 4" UP WALL FROM TOP OF FLASHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF ADHERING MEMBRANE REMOVE (E) VINYL SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE t FLASHING. REPLACE W/ NEW SIDING, ACCESSORIES, 4 BLOCKING TO MATCH (E). PRE- PRIMED, GALV SWEET METAL • - UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH: PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. et IN MASTIC AT EXTERIOR TRIM. REPLACEMENT SIDING AS REQUIRED SHIM BACKER BOARD AS REQUIRED (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" EXISTING VENT COVER EXISTING ROOF STRUCTURE EXISTING ROOF VENT EXISTING ROOF STRUCTURE V CROSS SECTION NEW 2 "X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION b" MIN. TYPICAL TOP 4 BOTTOM NEW I" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. 4 M RIDGE VENT BAFFLE DETAIL 1 1/2" = 1 - 0 EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS INSULATION DAM DETAIL 3 " =1' -0" r SUSPEND MECH UNIT FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL BLENDING UNIT MECH ATTACHMENT 11/2 " =1' -0" PIVOT HINGE CAULKING ADHESIVE ATTIC HATCH DETAIL 3 " =1' -0" INSULATION INSULATION DAM (E) WALL FRAMING INSTALL 2X BLOCKING AROUND OPENING AND FASTEN EDGES OF DRYWALL TO BLOCKING. ASSUME (E) CEILING JOISTS a 24" 0.C. EXTEND BLOCKING TO (E) CEILING JOISTS (TYP) (E) GWB SNAP FRICTION CATCH REMOVABLE DOOR PAINT DOOR AND FRAME TO MATCH (E) COLOR OF CEILING EXIST. WALL CONSTR. (2) SIMPSON A -34 e EACH SIDE PANEL OPEN TOP EXIST. GABLE VENT NEW i" GALV. HARDWARE CLOTH i" CDX PLYWOOD AT (3) SIDES I" OWENS CORNING 'T03 INSULATION, TYPICAL. SECURE WITH PIN TYPE FASTENERS TO PLYWOOD BACK AND SIDE PANEL NOTE: 1. AFTER FABRICATION, BAFFLE SHALL BE SECURELY ATTACHED IN POSITION. 2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS THE EXISTING VENT OPENING. GABLE VENT BAFFLE DETAIL 1 1/2 "= 1' -0" 171 SEALANT, ALL SIDES 1/4" TEMPERED GLASS EXIST. SKYLIGHT CONSTRUCTION ALUMINUM SLIDING SECONDARY SKYLIGHT WINDOW EXIST. CEILING SECONDARY SKYLIGHT - WINDOW DETAIL SET 1 1/2" = 1' - 0" EXPIRED MAR 1 22012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT STATE OF 0810.03.1835 TEMPE' .SHINGTON 2/24/11 F- O a 0 >- J a W Z 2 O w Q ce Z w Z LL-g V Ce U Q (' J Z Y ~ Z W D W MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 O z cn DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH MISC. DETAILS A2.2 0810.03.1835 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12" LAP SILL MEMBRANE FLASHING 1 -1/2" OVER (E) BLDG. PAPER AT SILL. EXTEND I i" BEYOND RO. AT EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASHING 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I" MN �1 1/2" TYP. (1 MEMBRANE FLASHING AT SILL Zg BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT SHOWN FOR CLARITY. NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. WINDOW NAIL FLANGE: - EMBED WINDOW HEAD AND JAMB NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND SHOULD FILL FLANGE NAIL HOLES. REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. B D ` ti 0 O a 0 O 0 o 0 0 0 0 MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. SEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGR4MAtICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER SACK DON OVER FLANGE FLASHING AT JAMBS (E) SHEATHING NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. r WHERE REQUIRED, TRIM (E) BLDG RAPER AT HEAD TO PRE ARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRI (FOLLOWI STEPS). L J HEAD FLASHING PREPARATION SCALE: NTS (E) BLDG. PAPER 2 SCALE: NTS NOTE: REMOVE (E) SIDING SACK FROM (E)120. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOW. EXTEND 1 -1/2" BEYOND EDGE OF OPENING AT HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB NOTE: REMOVE (E) SIDING SACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. INSTALL SNT. METAL HEAD FLASHING UNDER (E) BLDG PAPER. D 0 a 0 0 0 3 ' TYP. ( INSTALL SILL FLANGE FLASHING OVER WINDOW NAIL FLANGE AND FLASHING. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING WAS SEEN INSTALLED. ALLOW 1/8" CLEARANCE BETWEEN FLASHING AND SOT. EDGE OF (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOtLN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER MEMBRANE FLASHING AT HEAD 3� SCALE: NTS CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOUIN. EXTEND 1 -1/2" BEYOND R.O. AT HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) GENERAL NOTES: 1: MEMBRANE FLASHING IS SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND 1" REFER TO MEMBRANE INSTALLATION AFTER WINDOW HAS BEEN SET N PLACE, SHIMMED, AND ANCHORED. 4: DETAILS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. — INSTALL JAMB FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. MEMBRANE FLASHING AT JAMB NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOUN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. SCALE: NTS (E) SIDING (E) BLDG. PAPER BENEATH SIDING 0 WOOD TRIM INSTALLATION SCALE: NTS INSTALL WD. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND SACKER ROD IN GAP. ;It 0 L__ J WINDOW FLASHING INSTALLATION SCALE: NTS MAR 1 2 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVE JUL 19 2011 P i.»;w, +,, °v"d aTCENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 4220 REGISTERED A HITECT COTT STATE OF 0810.03.1835 TEMP SHINGTON 2/24/11 F- ce 0 I ce J z 0 z W F- z z 0 U 0 z C/) F- LU 2 W 0 fit > 0 W 2 W W 0 z u_ U cn ct AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1835 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR w WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL OR X 0 X/Y D DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. 6. 7. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4'-D» AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. 11. 12. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX ABBR + DN I 4" DN f l-UP� f S f f 1><1 GID R EQUIP ID #\•... �.�� x NG 171 • 3 0 D'Q UP DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA /EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SA SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X 25 1,2 - SWITCHES (ON, TIMER) ,-.J 120 1 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: AIDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" CEILING DECO 1, 2, 3 0G -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 3 RG -2 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1835 1331 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. 2,3q EXF MAR 1 21012 THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 4 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1 QF = 45 / (1 X 1 /2) = 90 CFM SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 1.9 2011 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Frotemiomrl Limited liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (200) 624 -2777 • FAX (205) 024 -2973 THE GRBENBUSCH GROUP, INC )6 Oa 0 0 4 alb 0) A0010 tlSIED i YEciwa 1. ElIOSiF7Ul0 1900 9S3f sir 9UIE 901 8ER11. it 9111111 (206) 376 -0609 (206) 378 -0041 FA% 0810.03.1835 KING COUNTY INTERNATIONAL AIRPORT U) F- z w w O 0 w w w co O F V ce e>t J z w 0 U) w Et AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1835 GAS METER W DINING ROOM ALL GRILLES LIVING ROOM CEILING GRILLES BEDROOM 2 MAIN FLOOR MECHANICAL PLAN SCALE: 1 /4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE ATTIC NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1 /A2.2 FOR DETAIL. BLENDING UNIT INSTALLATION DETAIL 01 WALL CAP INSTALLATION DETAIL NONE NONE RG -2 25 4"0, CONTINUED ON 1/M 2.0 BEDROOM 3 UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CUT AND PATCH CEILING AS REQUIRED TO INSTALL RETURN AIR DUCT AND GRILLE IN BEDROOM 2. DUCT PER PLAN EXi1ED MAR 1 2 2012 CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE INSTALLATION DETAIL NONE SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (208) eP.4 -2777 • FAX (806) 684 -!978 THE GREENBUSCH GROUP, INC ))) t� f� 11 STREET SUIE 901 SUM& 1M 118112 (200) 378- 0869 (206) 378 -0041 FAX 0810.03.1835 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN AND UPPER FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1835 15/1 P.-"N BLACK L -0 O N WHITE PANEL MP LOCATION: SERVING: DINING CONTROL EQUIPMENT 10.000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR WIRED UNDER DIVISION DESCRIPTION AIC, 200 AND with MAIN 15 16 CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 5 7 EXISTING LOAD EXISTING LOAD EXISTING LOAD X 60/2 20 20 A A B B 6012 40/2 - SWITCHES (ON, TIMER) EXISTING LOAD EXISTING LOAD 2 4 6 8 9 11 EXISTING LOAD EXISTING LOAD X 20 20 A B 20 20 1 EXISTING LOAD EXISTING LOAD 10 12 13 15 17 EXISTING LOAD EXISTING LOAD 2012 20 A A B 30/2 20 EXISTING LOAD EXISTING LOAD 14 16 18 19 21 EXISTING LOAD 30/2 A B 15 20/2 EXISTING LOAD EXISTING LOAD 20 22 23 25 27 29 SPACE SPACE SMOKE DETECTORS BLENDING UNIT M 1A 2 2011 ** 20/1** A A B B SPACE SPACE SPACE 24 26 28 30 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD 1.12 1.12 1.12 KVA 4.67 AMP COMPUTED LOAD 1.12 0.28 1.40 KVA 5.83 AMP p ISOLATED GROUND BUS 0 FEED THRU LUGS RAINTIGHT NEMA-3R ENCLOSURE p DOUBLE LUGS MAIN BKR SHUNTTRIP SERVICE ENTRANCE LABEL PANEL SKITS INTEGRAL SURFACE FLUSH ■ 1 • 0 ❑ TVSS ■ REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM MECHANICAL I ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLACK WHITE RED BLACK WHITE 1 BK WH R SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED ELECTRICAL LEGEND 8 ' M1 OL DESCRIPTION V DESCRIPTION IJGHTING OR POWER PANEL nil Li BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AM, 1/2 "C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. EQUIPMENT CONNEC11ON, SEE EQUIPMENT CONNEC11ON SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION a NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN FIRE ALARM SMOKE DETECTOR 120V OPERATED ELECTRICAL METER FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. TIMER OPERATED SWITCH THERMOSTAT ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 02 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PROVIDE NEW BREAKER IN EXIST PANEL TO MATCH EXISTING. 0 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. MAIN FLOOR PLAN 114" = 1' NORTH MAR 1 22012 ED EEDROOM 3 SEPARATE' PERMIT AND APPROVAL REQUIRED UPPER FLOOR PLAN RECEIVED JUL 19 2011 PERMTCENTER 1/4" = 1' S.M.S 1 EMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973. 0810.03A 835 I- Ct 0 0 J Z 0 F- W F- z Z 0 U 0 Z AIP NUMBER MPROVEMENTS 5 -53- 0058 -043 DATE ISSUED 02/24/11 BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1835