HomeMy WebLinkAboutPermit D11-236 - RUSSELL FOUR-PLEX - UPGRADESRUSSELL 4 -PLEX 11602 42 AV S EXPIRED 03-1 2-1 2 D11 -236 City ("Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400070 Address: 11602 42 AV S TUKW Suite No: Project Name: RUSSELL 4 -PLEX DEVELOPMENT PERMIT Permit Number: D11 -236 Issue Date: 09/14/2011 Permit Expires On: 03/12/2012 Owner: Name: RUSSELL WILLIAM P Address: 2801 S 128TH ST #100 , TUKWILA WA 98168 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: TRON CONSTRUCTION INC Address: 2845 N MAROA AV , FRESNO CA 93704 Contractor License No: TRONCCI9190A Phone: 206 - 296 -7437 Phone: 559 559 -7992 Expiration Date: 09/01/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $53,581.00 Fees Collected: $1,652.19 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -236 Printed: 09 -14 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: N N Water Main Extension: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pr construction or the performance of work. to this permit. Signature: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: / / /y /lJ Print Name: 1645 h 4A7E This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-236 Printed: 09 -14 -2011 this requirement. 0 4 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -236 Printed: 09 -14 -2011 CITY OF TUKWIL Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Building Permit No b IA ,.. 2...3 Mechanical Permit No Plumbing /Gas Permit No Public Works Permit No Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4201 S. 116th St. King Co Assessor's Tax No.: 3347400070 Suite Number: Floor: New Tenant: ❑ Yes 10 ..No Tenant Name: William P. Russell Property Owners Name: William P. Russell Mailing Address: 4201 S. 116th St. Tukwila WA 98178 City State Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296 -7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker @kingcounty.gov City State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H: \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORM PION - 206 -431 -3670 Valuation of Project (contractor's bid price): $ 53,581 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1° Floor 1,940 rd Floor 1,075 3r° Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:'Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 Oft PLUMBING AND GAS PIPING 2ERMIT INFORMATION - 206 -43 70 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type_grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:Wpplications\Forms- Applications On- Line\2009 Applications \I -2009 Permit Application.doc Revised. 1 -2009 bh Page 5 of 6 PERMIT APPLICATION NOTES— Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: Print Name: Timothy J. Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777 Seattle Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted: Date Application Expires: 1~ 1 --rte Staff Initials: H ^Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application doc Revised, 1 -2009 bh Page 6 of 6 CitOof Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011 RECEIPT NO: R11 -01600 Initials: WER Payment Date: 07/28/2011 User ID: 1655 Total Payment: 13,064.48 Payee: PAMELA K KUEHL SET ID: 071911 SET NAME: KING COUNTY HOUSING SET TRANSACTIONS: Set Member Amount D11 -222 748.15 D11 -223 716.64 D11 -224 1,092.10 D11 -225 993.76 D11 -226 622.10 D11 -227 653.61 D11 -228 1,067.51 D11 -229 685.13 D11 -230 685.13 D11 -231 716.64 D11 -232 1,018.34 D11 -233 559.07 D11 -234 811.18 D11 -235 1,042.93 D11 -236 1,652.19 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,064.48 TOTAL: 13,064.48 ACCOUNT ITEM ITEM LIST: Description Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 7,876.95 000.345.830 5,120.03 640.237.114 67.50 TOTAL: 13,064.48 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 98108 RE: Permit No. D11 -236 RUSSELL 4 -PLEX 11602 42 AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 03/12/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall t Technician File: Permit File No. Dl 1 -236 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -236 PROJECT NAME: RUSSELL 4 -PLEX SITE ADDRESS: 11602 42 AV S X Original Plan Submittal Response to Correction Letter # DATE: 07 -19 -11 Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: Bikw' ing Division I� o 1- Public Works u l�w� ►��� 01‘15C'11 Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 07 -21 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route NIX Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 08-18 -11 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page • • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TRON CONSTRUCTION INC UBI No. 602940001 Phone 5592297992 Status Active Address 2845 N Maroa Ave License No. TRONCCI9190A Suite /Apt. License Type Construction Contractor City Fresno Effective Date 9/1/2009 State CA Expiration Date 9/1/2013 Zip 93704 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date DONALDSON, RON ARDEN President 09/01/2009 Amount DONALDSON, SHARYN Secretary 09/01/2009 LHA135245 DONALD, SHARYN Treasurer 09/01/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO WCL1256498 09/01/2009 Until Cancelled $12,000.00 08/05/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 American Ins Co Landmark American LHA135245 03/01/2011 03/01/2012 $1,000,000.00 03/07/2011 2 LANDMARK AMERICAN INS CO LHA134615 03/01/2010 03/01/2011 $1,000,000.0003 /10/2010 1 LANDMARK AMERICAN INS CO LHA133917 03/01/2009 03/01/2010 $1,000,000.00 08/05/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 AS Ilk City of Tukwila BUILDING DIVISION] KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24 5- 53- 0058 -043 SEPARATE PERMIT REQUIRED FOR: C Mechanical gitiectricai efflumbing Gas Piping City of Tukwila OI N�; DIVISION MAR ,1 .2 2012 FILE' COPY Permit No. D i v- 23(p Plr.T review approval is subject to errors and omissions. A ;:i o al of construction documents does not authorize th`: violation of any ado e or ordinance. Receipt of approved Field 's acknowledged: By Date: 7 9'%fh City Of 1Ukwiia BUILDING DIVISION PRIOR TO COMMENCING WITH DEMOLITION A "pre -demo inspection" is required. Contractors shall provide documentation that an "asbestos survey" has been completed. If needed, abatement procedures per "Puget Sound Clean Air Agency" shall be completed and documentation of compliance shall be provided at time of final inspection. For alb REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Fs visions will require a new plan submittal ah, may inc:ude additional plan review fetes. I SITE AND BUILDING INFORMATION JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, international Mechanical Code 3341400010 LEGAL DESCRIPTION: HILLMANS MEADOW GARDENS DIV • I ZONING: SF1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE CONSTi,JCTION TYPE: (No Chance) V B NON SPRINKLERED DUILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: DRAWING INDEX T0.0 TITLE SHEET, PROJECT INFO. 41.0 FLOOR PLANS 4 NOTES 42.0 WINDOW TYPES, SCHE=DULE 4 DETAILS 42.1 DOOR TYPES, SCHEDULE 4 DETAILS 422 MISCELLANEOUS DETAILS 42.3 WINDOW FLASHING DETAILS 111.0 LEGENDS, SCI- IEDULES, ABBREV., GENERAL NOTES 4 DUJG INDEX M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS Et0 FLOOR PLANS AND NOTES PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296. 0190 Contact: Sharyn Parker E -mail: Sharyn.Parkerekingcounty.gov ARCHITECT: S.M. Stemper Architects PL.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624.2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Fenlason, E -mail: Jerryesmstemper.com melodyesmetemper.com timeemstemper.com ACOUSTICAL ENGINEER: SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Alt Allaoua E -mail: mohamedeesaacoustica.com MECHANICAL ENGINEER: The Greenbusch Group 1900 West Nickerson St, Suite 201 Seattle, WA 98115 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Chris Ager E -mail: ChrisAegreenbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswest.com REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162.4180 Contact: Tim Ogden E -mail: tim ogdenepbsenv.com DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. 4200 Boston, MA 02114 Contact: Tim Feniason/ Jim Cornwell E -mail: JCornwellejonespayne.com RECEIVED JUL 19 2011 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824 -2777 • FAX (20B) 824 -2973 4220 SCOTT I srATE< OF 0810.03.1838 TENOE 3RN(,TON 2/24/11 ce 0 0 ct >- Q LLI O Et � W Z W ce Z z 0 0 —i Z W 0 C/) W MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 081 0.03.1 838 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. NE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 020S1 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. �U V 5 E. 0 ROOM efEDi" Oc 1"1 2 ?A°-4 L� r T GPI -1% LIVING ROOM NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO S•.00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. Z. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. I1. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A10 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET EIS FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM DOVER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5 :00 PM. I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. IS. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. UNIT A a: MAIN FLOOR PLAN 1/4" = 1' Li LI VFW ROOM LLa I E�J Ja,t -a �I 1' OCA- 7 ..L_� -_J� II� 5A", H PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0 2 O DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET A2.I ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL. OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REEF. ELECT. FOR 5PEE0 CONTROL AND DISCONNECT. REF. 1/A22 FOR PETAL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO I- IMEOUNER DRIVEWAY. 0 UNIT 3I D ROOM r E< DP. Oi"f 2 LEGEND I• i J \-2Ap I ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.I O SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION WALL GRILL IGAS NOT USED MAR .12'2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED GAS METER RECEIVED JUL 19 2011 P`.oe .TCENTEP. S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1838 2/24/11 —J .e� z 0 z w z KING COUNTY MPROVEMENTS a w w ct w 0 z IL U ce co ct AIP NUMBER 5 -53- 0058 -043 z 0 F- z w DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1838 WINDOW TYPES SINGLE HUNG 2 CASEMENT • 3 SLIDER/ FIXED/ SLIDER 4 CASEMENT/ FIXED WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A BEDROOM I 2 2' -10" x 3' -10" STAIN/PAINT SAFETY GLAZING REQUIRED Y 1/A2.0 B BEDROOM I I 5' -10" x 1' -I0" STAIN/PAINT I /A2.0 C BEDROOM 2 I 5' -10" x 1' -I0" STAIN/PAINT I /A2.0 D BEDROOM 2 2 2' -I0" x 3' -10" STAIN/PAINT Y I /A2.0 E KITCHEN I 2' -0" x 2' -10" STAIN/PAINT I /A2.0 F LAUNDRY ROOM 3 5' -4" x 4' -4" STAIN/PAINT SAFETY GLAZING REGURED I /42.0 G LIVING ROOM 4 4' -4" x 3' -10" STAIN/PAINT SAFETY GLAZING REQUIRED 1/42.0 (E) = EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD SACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH 211 WINDOW HEAD (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATCH WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING WINDOW JAMB 0 WINDOW SILL (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT IX WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IX WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3" = 1' - 0" TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. VI— 2.3(e EXP MAR ,12 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 192011 PERMIT CENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 COTT T.EMPE STATE OF HINGTON' 0810.03.1838 2/24/11 H O a Q J Z 0 z w H z z 0 U 0 Z MPROVEMENTS D W W W 0 H U Q J Q Z W co D W AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1838 DOOR TYPES ®,® 0 ,4 FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -8" STAIN/STAIN 1-1W-1/ 626 DK -2 LOCK -1 1/42.1 2 LAUNDRY ROOM A 2' -S" x 6' -S" STAIN/STAIN HW —I / 626 DK -2 LOCK -1 I /42.1 3 ENTRY 5 3' -0" x 6' —S" I /42.1 4 LAUNDRY ROOM B 2' —S" x 6' -S" 1/42.1 (E) STUCCO TO REMAIN BACKER ROD AND SEALANT PRE— PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MN. (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR LATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP ALUMNUM THRESHOLD ADJUSTABLE SWEEP DOOR JAMB EXISTING FLOOR STRUCTURE 0 DOOR SILL STUCCO - DOOR DETAIL SET (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE 3 "= 1' -0" TYPICAL DOOR SCHEDULE NOTES 1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. EXPI ` ED MAR 1 2 2011 III -2,5e REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELEIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT STATE OF 0810.03.1838 TEMPE: .aHINGTON 2/24/11 0 0 ce J z 0 z c w 1— z z 0 U z MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1838 (E) STUCCO TO REMAIN (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING SACKER ROD 4 SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT NTERIOR WI ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN NE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIPES (PT.) AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" I --2_,;(R SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS n 16 ", INSTALL 2X4 STUDS * 16" O.C. 5 /S" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12"X16" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 1 1/2"=1'-O " EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS SOFFIT DETAIL EX MED MAR 1 2 2011 ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING: TO LEDGER. COAT)" x 1" WD BLOCKING W/ ADHESIVE AND INSERT AT (E) GWS PANEL EDGE. PROVIDE FINISH -GRADE PAINTABLE GM EDGE AND CAULK JOINT DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS I6 ", PROVIDE 2x2 SOFFIT FRAMING ® 16" O. 2x2 CONT. NAILER 8" GWS- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 1 1 /2" = 1' - 0" MATCH EXIST. SOFFIT HT. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.M.STEMPER ARCHITECTS A Profeaeional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 624 -2777 • FAX (208) 824 -2973 REGISTERED HITE:CT GOTT 4TEMPE • STATE OF SHINGTON 0810.03.1838 2/24/11 0 0 J < � Q O w ix Z U1 O H Z z � gll- Z O U < 0 --I Z Q z w 0 w ce MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 Z O H 0 z DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1838 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP H VAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR XX OR XX DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK 0 ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION ED EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL SG -X XXX 4- I DN I IF up I f t + f + ■ DN UP VD RA /EA RG SA SA -el- 0-1- RA /EA CjZOR EQUIP ID# .l: 171 SD EA MOD NG NG • 0 D'a DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1838 602 2 90 CFM 90 CFM IN CEMENT SLAB OR IN GROUND 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. MAR .1 .22011 III-- 23(a THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) la &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION la. QF = 45 / (1 X 1/2) = 90 CFM SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Professional Tinned liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (20e) 624 -2073 THE GREENBUSCH GROUP, INC ))) NYIIO Z tit 201 MI. E.INEa010 Tarn �r sir s6� MOUE. IN 1111110 (206) 378 -0660 (206) 376 -0641 FAX 0810.03.1838 KING COUNTY INTERNATIONAL AIRPORT F- z w ME 0 w 0 a w w w O z F- w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1838 BEDROOM 2 SEE M2 O TYP ALL WALL GRILLES SOFFIT BY OTHERS BV -1 LOCATED IN CLOSET SOFFIT BEDROOM UNIT A MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE CLOSET SOFFIT COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS MN TECHNIC L REPRESENTATIVE NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL KITCHEN LIVING ROOM NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO NE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL 2.(p NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE INSTALLATION DETAIL 4 () NONE SEPARATE PERMIT AND APPROVAL REQUIRED �D MAR 1.2 2011 RECEIVED JUL 19 2011 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Proferdo eal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200• SEATTLE, RA 98106 (20e) e24 -2777 • FAX (200) 024 -297' THE GREENBUSCH GROUP, INC 10102101/ DINNEBI ))) 1 MlaON SIREN CIE 201 t 9 (200) 378 -0589 (200) 378-0541 FM 0810.03.1838 KING COUNTY INTERNATIONAL AIRPORT i- z w w 0 Elf 0 w w w O z LL AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1838 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5: 00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810.03.1838 SYMEOL 10,000 120!240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE AIC, 100 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. I I I CKT LOAD DESCRIPTION TYPE KVA APP PHASE] A"P KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD —�- E3 40/2 A B 30/2 AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. EXISTING LOAD 2 4 5 EXISTING LOAD 20/2 A 30/2 EXISTING LOAD 6 7 9 11 SPACE SPACE SPACE PHASE LOAD PHASE A= KVA PHASE B= 2011 1511 #VALUE! A KVA. B B 1511 20/1" EXISTING LOAD BLENDING UNIT 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS ❑ RAINTIGHT NEMA-3R ENCLOSURE ❑ DOUBLE LUGS MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH 1 ❑ REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. ELEcTRIcAL LEGEND SYMBOL DESCRIPTION SYMEOL DESCRIPTION G UGHIING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. I I I 1 9 DAMPER CONNECTION ❑' NON- FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD ❑S' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN OD SMOKE DETECTOR —�- E3 ELECTRICAL METER TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. TO THERMOSTAT — - — 1IEci- IANIcAL ! ELEcTIRIcAL cooRD IN4TION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 N/A 15 16 N/A REMARKS BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH 5E D ROOM 2 SEDROOM MP /12 15ATI -1 LAUNDRY' MAR 1.2 2012 ED 0810.13.1838 UNIT A EXISTING ELECTRICAL PANEL KITCI -1N LIVING ROOM KITCHEN LIVING ROOM NORTH 15ATH SEDIROOM 5EDF SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 ENGINEERS, INC IRS MINH 4/110 Smr. 111111 wr 7M9oIK WA oNSN •TSN MINIM IMP NB tasa I $asaa«. 0810.03.1838 0 IZ -J z 0 F- z LLI F- z z 0 U 0 z AIP NUMBER MPROVEMENTS D W W W 0 Ct z D 5 -53- 0058 -043 z. 0 F- 0 z_ DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1838 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. >e MATH NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5 :00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL WAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT SE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS I SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQD MD RE- CONSTRUCT SHELVING IN COORDINATION WIN SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMI9"I POUER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. I AFTER 5:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. UNIT A 2 L4UNL) 1 KITCHEN LIVINcix ROOM 1t UNIT 1 7 v r� L, I VINE ROOM T I MAIN FLOOR PLAN 1/4" = 1' UNIT 5 E MAR 12'Z011 PLAN KEYNOTES OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, MD THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON 5HEET A2.1 ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH MECHANICAL. OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/A22 FOR DETAIL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. 1:") \ 1 ..... 2:0000b(„ ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. NORTH REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION LEGEND f I ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 O SEE WINDOW SCHEDULE FOR WINDOW TYPES T / E FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED WALL GRILL NOT USED ATTIC INSULATION RECEIVED JUL 19 2011 TC SD INSTALL BATTERY OPERATED SMOKE DETECTORS I, I NOT USED GAS METER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAK (206) 824 -2973 REGISTERED A` HITE.CT 0810.03.1839 TEMPE i+SHINGTON 2/24/11 �C 0 a_ J z O I— z w H z z 0 U 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1839 WINDOW TYPES FIXED U/ OBSCURE SAFETY GLAZING 2 CASEMENT 2i0" MIN_ 3 SLIDER/ FIXED /SLIDER 4 CASEMENT/ FIXED WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 1 1' -0" x 6' -6" STAIN/PAINT 1/42.0 B LIVING ROOM 4 4' -4" x 3' -10" STAIN/PAINT 1/A2,0 c BEDROOM 1 3 5' -I0" x I' -10° STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 55" y 1/42.0 0 BEDROOM 2 3 5' -I0" x I' -10" STAIN/PAINT 1/42.0 E BEDROOM 2 2 2' -10" x 3' -10" STAIN/PAINT Y 1/42.0 (E) • EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE HELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOU ASSEMBLY BACKER ROD t SEALANT WINDOW HEAD ,J11 tyl■ 1L WINDOW JAMB STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING 0 WINDOW SILL (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATC WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT (E)G WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT IX WOOD LEDGER SEALANT BED SEALANT 4 BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM IX WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3 " =1' -0" TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 0SS00 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. EXPI MAR 12'2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 JERM1TCENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 RE.GI < =rERED �,TTlllP 'i,...:TurrECT Y'... ,. COTT TEPE STATE OF r HINGTON 2/24/11 0810.03.1839 H O CL J Z O z w F- z z 0 U 0 Z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 0 z DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN A A, LB &J H WINDOW TYPES, SCHEDULE & DETAILS A2.0 081 0.03.1839 DOOR TYPES Oik O FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM ID/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE W x H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -S" STAIN/STAIN 14-1 / 626 DK -2 LOCK -I 1 /A2.1 2 ENTRY B 3' -0" x 6' -S" 1 /A2.1 PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN NE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER - STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP 2" MIN. DOOR JAMB EXISTING FLOOR STRUCTURE 0 DOOR SILL STUCCO - DOOR DETAIL SET (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP WI BATT INSULATION DOOR PER SCHEDULE 3 "= 1' -0" EXPI': ED MAR 1 2'2012 TYPICAL DOOR SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING POOR OPENING DIMENSIONS. 171 •• 7,59 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER ■ S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (200 624 -2973 REGI }TEFED ti HITE:CT COTT 4TEMPE! STATE OF r SHINGTON 0810.03.1839 2/24/11 0 0 ce a J Z Z W H Z Z O U C� Z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 z 0 I- (9 Lctz_ C!) co DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1839 (E) STUCCO TO REMAIN SACKER ROD 4 SEALANT Pte- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR WI ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL WHERE WIDTH OF SOFFIT EXCEEDS I6 ", INSTALL 2X4 STUDS e 16 OC. 5 /S" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12 "X16" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 1 1 /2" = 1' - 0" EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS EX MAR .1 22012 ATTACH 2x3 LEDGER TO EXIST. DECK ATTACH SOFFIT FRAMING TO LEDGER SOFFIT DETAIL 11/2 " =1' -0" COAT x I" WD BLOCKING WI ADHESIVE MD INSERT AT (E) GWB PANEL EDGE. PROVIDE FINISH -GRADE PAINTABLE GM EDGE AND CAULK JOINT DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS 16 ", PROVIDE 2x2 SOFFIT FRAMING • 16" O.C. 2x2 CONT. NAILER 54" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. MATCH EXIST. SOFFIT HT. ED REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 IPERMITCENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1839 2/24/11 0 cc a z w O W Ce Z CC Cr) 11-1 0 z Z Z V O U Q J Z a Y ~ Z W 0 CO W MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03A 839 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP H VAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB WI WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR XX 0 OR XX 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON NE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL ABBR $G X XXX + f + r%J DN UP VD RA /EA RG >CI SA SA RA /EA SD EQUIP ID# �- ICI EA MOD NG NG • 0 D'4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WIN TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALOES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 140 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 2 SG -1 140 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALOES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1839 597 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. EXPIRED MAR 1 2 2012 1- 2__Vto THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 4a &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Prefe..lonal Limned 'MAW" Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (20e) 624 -8777 • FAX (206) 884-8 973 THE GREENBUSCH GROUP, INC M••Sii. Se) 19(206) te 3-6n AD 9 VIDEO i 11192181001. ENGINEERING ST EET SD 901 SEATTLE. 90110 (20e) 37e -0041 FAX 0810.03.1839 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1839 KITCHEN LIVING ROOM [I BEDROOM UNIT 13 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1P-0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE COORDINATE ACCESS HATCH FOR ELECTRICA AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE C-2) SOFFIT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 2. HEATING IS PROVIDED BY ELECTRIC UNIT HEATERS. DUCT PER PLAN FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL EX 1 ED MAR 1 2 2012 PI 1 2z(ia NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 08108 (206) 624 -2777 • FAX (206) 624 -2073 THE GREENBUSCH GROUP, INC 10011.180 11TrS,r Allma 1iI11E0 1 �1 gA11ll 9 (209) 378 -06811 (206) 379-0841 FAX 0810.03.1839 z w ft 0 O oC Q z w 0 w rt w z Z � V O V < J Z Q ;- z w w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID GROUP M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, DO, MM &JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1839 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN 5:00 PM. ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810.03.1839 5111501. 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE ABC, 100 AMP with MAIN BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. III I 1� 0 DAMPER CONNECTION CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD i 4012 A B 30/2 ®T THERMOSTAT EXISTING LOAD 2 4 5 EXISTING LOAD 20/1 A 30/2 EXISTING LOAD 6 r 7 9 11 SPACE SPACE BLENDING UNIT PHASE LOAD PHASE A= KVA PHASE B= 15/1 15/1 2011** #VALUE! A KVA. B B 20/1 EXISTING LOAD 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS ❑ RAINTIGHT NEM1\-3R ENCLOSURE ❑ DOUBLE LUGS MAIN BKR SHUNTTRIP ❑ PANEL SKIRTS ❑ SURFACE SERVICE ENTRANCE LABEL 0 INTEGRAL TVSS ❑ FLUSH ■ D REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM, ELECTRICAL LEGEND SY111301 DESCRIPTION 5111501. DESCRIP'T'ION G LIGHTING OR POWER PANEL m EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. I INDICATES ISOLATED GROUND. III I 1� 0 DAMPER CONNECTION ❑' NON -FUSED DISCONNECT SWITCH o MAST, WEATHERHEAD ❑S' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN 0) SMOKE DETECTOR ELECTRICAL METER i TIMER OPERATED SWITCH AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. ®T THERMOSTAT — - — 11ECMANICAL I ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 N/A 15 16 N/A REMARKS BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH KITCHEN 1vING ROOM 7 0810.13.1839 UNIT B EXISTING ELECTRICAL PANEL 54TH 5EIDROCM EKED ROOM 2 MP /11 MAIN FLOOR PLAN 114" = 1' EXPIRED MAR 1 2'2012 SEPARATp D PERMIT APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMITCENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 E NGINEERS, INO N w NOON MO MIR NA• ON 7AMNA. WA MIME MINIM OM IN MM ✓ x SIN 4111 ONO 0810.03.1839 H ce O a J Z 0 H Q z w H z z 0 U C7 Z AIP NUMBER MPROVEMENTS 5- 53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1839 -L1 5tHE ( mil ✓4..11 I J 1 N 1 f rat I .._ VING ROOM &-E ROOK i 3 I I' L ,4TH ■ LAUNDRY" KITCHEN / \ 1 / / LI° `ING / / ROOM / 1_��, / I / I LL -- KITCHEN IN \ EXIST. ROOF LINE \ L IV!NG\ ROOM \ 1 I L UNIT 5 2 r MAIN FLOOR AND ROOF PLAN 1/4" = 1' NOTE: I. LEAD PAINT IS PRESENT AT TI-115 RESIDENCE. REFER TO SECTION 01011 AND 02081. NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OWNERV FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE MD ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 8 :00 AM AND 5:00 Ml. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. B. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERVERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D MD RE- CONSTRUCT SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SI4ELVNG SO AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. HELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST EE PROVIDED AT RESIDENCE BEFORE 8:00 All. 4 AFTER 5 :00 F.M. l6. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. J BEDROOM CLOSET 5,4T1-1 18" x 24" EXIST. ATTIC ACCESS PANEL CLOSET (7/' KITCI-4EN DINING ROOM BEDROOM 2 CLOSET L1 CLOSET BEDROOM 3 LIVING ROOM U jr IC - - --� r- --ter —_J I I I I I L__1 J L P / - 18" x 24" EXIST. ATTIC ACCESS PANEL A UPPER FLOOR PLAN 1/4" = 1' / / / / \ / / / -I 1 r— NO INSULATION REQUIRED - \ \ I II �✓ V \ MAR 12'20121 1 I�/ = n _ N 1 L_ .\1 A. NORTH ELEVATION B. EAST ELEVATION PLAN KEYNOTES 00000000 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0 DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET 42.1 DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH MECHANICAL. BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED N ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. COORDINATE CEILING GRILL WITH MECHANICAL. INSTALL VENT BAFFLE(S) AT EXISTING RIDGE VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL. INSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/422 FOR DETAIL INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. C. SOUTH ELEVATION D. WEST ELEVATION LEGEND ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL EXISTING KITCHEN EXHAUST /7E ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE NOT USED NOT USED NOT USED REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVE JUL 19 2011 p-. xoTCENTER SD INSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE GAS METER _ 71110 S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 824 -2973 REGISTERED A;,HITECI 2/24/11 0810.03.1840 MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS CX NOTES A1.0 0810.03.1840 WINDOW TYPES SINGLE I4UNG 2 SLIDER/ FIXED/SLIDER 3 CASEMENT WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 6' -0" x 4' -0" STAIN/PAINT - 1/42.0 B LIVING ROOM I 3' -2" x 3' -10" STAIN/PAINT 1/A2.0 C LIVING ROOM I 3' -2" x 3' -I0" STAIN/PAINT 1/42.0 D DINING ROOM I 3' -2" x 3' -10" STAIN/PAINT 1/42.0 E DINING ROOM 2 6' -6" x 2' -6" STAIN/PAINT 1/42.0 F KITCHEN I 3' -6" x 4' -0" STAIN/PAINT 1/42.0 G BEDROOM 1 I 2' -4" x 5' -5" STAIN/PAINT 1/42.0 H BEDROOM 1 I 3' -4" x 5' -5" STAIN/PAINT 1' 1/42.0 I BEDROOM 2 I 3' -4" x 5' -5" STAIN/PAINT Y I /42.0 J BEDROOM 2 I 2' -4" x 3' -4" STAIN/PAINT 1/42.0 K BEDROOM 3 3 2' -4" x 4' -0" STAIN/PAINT Y I/42.0 L CORRIDOR (ABOVE STAIRS) I 2' -8" x 3' -2" STAIN/PAINT 1/42.0 (E) = EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL HOLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE - PRIMED, GALV 51-IEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN STUCCO FIN BEHIND (E) LATH 114 WINDOW HEAD (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MAT WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING WINDOW JAMB IIII IIII 11 11 ICI 0 WINDOW SILL (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD I SEALANT IX WOOD LEDGER SEALANT BED SEALANT 4 SACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM 1X WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3 " =1' -0" TYPICAL WINDOW SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 05800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL SEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. 1EXPI ED MAR 1 2 2012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER • S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT STATE OF 2/24/11 0810.03.1840 TEMP aHINGTON 0 a z 0 z w z 0 v z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1840 DOOR TYPES 0 IA FLUSH SCW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 2'4" x 6' -6" STAIN /STAN HW -I / 619 DK -1 LOCK -I 1/A2.1 2 ENTRY B 2' -S" x 6' -6" 1 /A2.1 INSTALL SPRING LOADED HINGES TO DOOR 1 (E) STUCCO TO REMAIN BACKER ROD AND SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MN. (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BAIT INSULATION WOOD FRAME KEW AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTNUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT (E) EXTERIOR PLYWOOD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP 2" MN. DOOR JAMB EXISTING FLOOR STRUCTURE DOOR SILL EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SH111 AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE STUCCO - DOOR DETAIL SET 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 05600 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. 17Il -7,3(e EXPIRED MAR 1 2 2012 ; REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER ■ S . M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 REGISTERED A.CHITECT lollP! COTT V T:EWE: STATE OF. SHINGTUN 2/24/11 0810.03.1840 Et O a Q J Z 0 Q z ac w z z 0 0 0 Z AIP NUMBER MPROVEMENTS 5- 53- 0058 -043 z 0 F- 00 Lil z_ DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1840 (E) STUCCO TO EMAIN BACKER ROP 4 SEALANT ME-PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR WI ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC At EXTERIOR TRIM. PRE - PRIMED, GALV SWEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING (E) EXTERIOR PLYWOOD (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3 " =1' -0" PREMANUFAGTIIRED ROOF BAFFLE ! AN- MODEL EXIST DUCTWORK •Pk EAL4,k NAILS WITH ROOF CEMENT SEAL SHINGLES TO ROOF CAP ON TOP AND SIDES NOTE: I PREMANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURE'S INSTRUCTIONS. KITCHEN EXHAUST BAFFLE 11/2 " =1' -0" BLENDING AIR UNIT ACCESS PANEL 1 1/2 "= 1' -0" SUSPEND MECI.4 UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL DISPLACE (E) INSULATION TO FACILITATE INSTALLATION OF MECHANICAL UNIT, DUCTS AND ACCESS HATCH CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL INSULATION STOP AT PERIMETER OF ACCESS HATCH OPENING, 4 SIDES - 2x WD BLOCKING EXISTING VENT COVER EXISTING ROOF STRICTURE EXISTING ROOF VENT EXISTING ROOF STRUCTURE CROSS SECTION NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS * 16" O.C. J -METAL EDGE AND CAULK JOINT (E) ATTIC LATERAL SECTION RIDGE VENT BAFFLE 11/2 " =1' -0" DUCT CHASE 4064 /1 /! Fr 411114111111 14 r c SOFFIT DETAIL EX MAR 1 2'2012 6" MIN. TYPICAL TOP 4 BOTTOM NEW P' INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. DEMOLISH (E) GWB REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FULL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETWEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5 /S" GWB- FAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE LW ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WD FRAME WALL ASSEMBLY 11/2 " =1' -0" RECEIVEr JUL 19 2011 PERMIT CENTEF • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 COTT 4 T.EMPE STATE OF l HINGT)N 2/24/11 0810.03.1840 O 0 J Q z 0 z w H z 0 U z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1840 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTU H CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEIUNG BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEIUNG DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANI ZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STA11C PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STA11C PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE IMTH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR AC) OR XX 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEIUNGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 10. 11. 12. SYMBOL SG -X XXX ABBR UP I + f f Swm- N -11) I- 4R-I- DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT 4.VD RA /EA OR EQUIP ID NG • 3 0 DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SA SUPPLY AIR DUCT RA /EA RETURN AIR OR EXHAUST AIR DUCT SD SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WI11-I BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STA11C PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" CEILING DECO 1, 2, 3 OG -1 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" CEILING DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WI11-I BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1840 1148 3 90 CFM 90 CFM 1,3 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. EXPI E MAR 1 22012 THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) II &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION ] QF = 45 / (1 X 1/2) = 90 CFM RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE T AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2Y73 THE GREENBUSCH GROUP, INC 011•00 ))) A001)SflCM., AUpO VIDEO t ME WIa*L Eg0IE�IG 1900 9F91 sir SUITE 701 9FA1Rz M Mill (206) 376 -069 (206) 378 -0041 FAX 0810.03.1840 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1840 BEDROOM SEE BATH BEDROOM 2 BEDROOM B.C2=1 3 25 IDINING ROOM TYP ALL CEILING GRILLES LIVING ROOM UPPER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE USE EXISTING ATTIC ACCESS HATCH FOR ELECTRICAL AND MAINTENANCE ACCESS ATTIC NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE UNIT C NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE FLAG NOTES: 13V -1 AND DUCTWORK ROUTED IN ATTIC. USE EXISTING ATTIC ACCESS HATCH FOR MAINTENANCE AND ELECTRICAL ACCESS. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. DUCT PER PLAN SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE DUCT PER PLAN NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER 2. SEE PLANS FOR VOLUME DAMPER LOC 3. CEILING SUPPLY INSTALLATION SHOWN, COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE CAULK FOAM BACKER ROD ARCHITECT TO PROVIDE 2X4 BLOCKING TO SUPPORT CEILING CUTTING FLOOR OR CEILING JOIST CEILING SLEEVE AND ESCUTCHEON GRILLE MANUFACTURER'S WRITTEN INSTRUCTIONS. ATI ONS. RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE EXPIRED MAR 1 2 2012 RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE PERMIT AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS A Pro2ei tonal Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, 1►A 98106 (2011) 624-2777 • FAX (206) 624 -8973 THE GREENBUSCH GROUP, INC 0... ))) uoR .ENO lee) & IE IWI L OL IO slil6Er m1 S .►.eii. (206) 376 -0589 SPASM 378-01141 FAX 0810.03.1840 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLANS AND DETAILS M2.0 0810.03.1840 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN 5:00 PM. ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES 0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. O4 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. PANEL MP LOCATION: SERVING: 0810.03.1840 SYMBOL 100,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE AIC, 100 AMP with MAIN AND EQUIP R INDICATED ON PLANS. CONDUIT (WIRING AND! CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. Ink 1k 0 CKT LOAD DESCRIPTION TYPE KVA A/P PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD ELECTRICAL METER ® 40/2 A B 30/2 TIMER OPERATED SWITCH EXISTING LOAD 2 4 5 7 9 11 EXISTING LOAD EXISTING LOAD EXISTING LOAD SPACE PHASE LOAD PHASE kz #VALUE! KVA PHASE B- 20/1 20/1 20/1 #VALUE! A A KVA. B B 20/2 2011** 2011 ** EXISTING LOAD BENDING UNIT SMOKE DETECTORS 6 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ISOLATED GROUND BUS RAINTIGHT NEMA -3R ENCLOSURE ❑ FEED THRU LUGS DOUBLE LUGS ❑ MAIN BKR SHUNTTRIP SERVICE ENTRANCE LABEL PANEL SKIRTS ❑ SURFACE INTEGRAL TV SS ❑ FLUSH III ■ ❑ ■ ■ 11 REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. 15/1 t'1 BLACK L —O O N WHITE ELECTRICAL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION G LIGHTING OR POWER PANEL EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. AND EQUIP R INDICATED ON PLANS. CONDUIT (WIRING AND! CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. i INDICATES ISOLATED GROUND. Ink 1k 0 DAMPER CONNECTION D' NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD OS' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS BRANCH CIRCUIT HOME RUN 1 D FIRE ALARM SMOKE DETECTOR 120V OPERATED �- I-131 ELECTRICAL METER ® FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED AERIAL SERVICE CONDUCTORS, COORDINATE WITH U111JTY. TIMER OPERATED SWITCH — - — T® THERMOSTAT tA\--9.ze BLACK WHITE RED BK BLACK WHITE SMOKE DETECTOR WIRING DIAGRAM NO SCALE RED MECHANICAL ! ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 N/A 15 16 N/A REMARKS BV -1 BLENDING UNIT VENTILATOR 120 1 X X 1,2 SWITCHES (ON, 11MER) 120 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL AL) 2 - DISCONNECT SWITCH 0810.13.1840 UNIT C ELECTRICAL PANEL IS LOCATED IN HALLWAY ON MAIN LEVEL NEAR THE STAIRWELL ®INING R®01'1 EXPI "ED UNIT C SEPARATE PERMIT AND APPROVAL REQUIRED MAR 1 2 2012 RECEIVED JUL 19 2011 PERMITCENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 1111011111111113. 1110 U M WM ISO .nor. SIMI wI =Men UM A.R. II..I IA MOUS 0810.03.1840 F- 0 a J Z 0 z w H z z 0 0 0 Z AIP NUMBER MPROVEMENTS 5 -53- 0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1840 NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT TH15 RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL 8E RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. 7 E Imo+ C,7i1 2 R ..00M um-r MAIN FLOOR PLAN 1/4" = 1' NOTE: INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1. CONTRACTOR TO PROTECT OII,NERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3, ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO S:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 All AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WIN SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WIN THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. II. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M. 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY NAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED. 13 EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. r KI 1..IViN ROOM rr BEDROOM 3 l ._._..�-- ..- .-- ..._r_._.? I I I ! I ! I 1 i I 5ELD ROOM MAR 1 2 2012 ,ATM PLAN KEYNOTES I DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2,0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF. DOOR SCHEDULE ON SHEET All ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH MECHANICAL. 4 O BLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL. OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION DETAIL. ® INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL. c wl �� 40.5.0° 20„,... S t ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. E3EIDROOM 2 L IN1T REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION A. NORTH ELEVATION B. EAST ELEVATION C. EAST ELEVATION D. SOUTH ELEVATION E. WEST ELEVATION LEGEND T T ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR: DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. A2.1 SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL NOT USED ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. NOT USED 11111 WALL GRILL !GAS NOT USED NOT USED ECEIVED JUL 19 2011 P _,-..Y,.TCENTER INSTALL BATTERY OPERATED SMOKE DETECTORS NOT USED GAS METER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 824 -2973 REGISTERED A HITECT 0810.03.1841 TEMP u SHINGTON • 2/24/11 0 a. J z 0 1 z w z z O 0 00 z MPROVEMENTS AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS NOTES A1.0 0810.03.1841 WINDOW TYPES 2'L 0" 1'11N. SINGLE HUNG 2 SLIDER/ FIXED/SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A LIVING ROOM 2 5' -4" x 4' -4" STAIN/PAINT SAFETY GLAZING REQUIRED I/A2.0 B KITCHEN I 2' -0" x 2' -10" STAIN/PAINT I /A2.0 C BEDROOM 1 1 2' -10" x 3' -10" STAIN/PAINT I /42.0 D BEDROOM I 2 5' -10" x 1' -10" STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 5T' Y 1/42.0 E BEDROOM 2 2 51-1011x I' -I0" STAIN/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) Ht. 5i" y 1/42.0 F BEDROOM 3 I 2' -10" x 2' -I0" STAIN/PAINT 1/A2.0 G BEDROOM 3 2 5' -S" x 2' -0" STAIN/PAINT SAFETY GLAZING REQUIRED Y 1442.0 (E) 2 EXISTING (E) STUCCO (E) STUCCO UNDERLAYMENT SEALANT COUNTERSINK SCREWS AND FILL 1-IDLES TYP. (E) EXTERIOR SHEATHING NEW STUCCO PATCH, MAINTAIN WIRE MESH REINFORCEMENT. STUCCO DRIP SCREED PRE - PRIMED, GALV SHEET METAL FLASHING UNDER SELF- ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN MANUFACTURED Z -BAR FRAME ACCOUSTICAL WINDOW ASSEMBLY (E) EXTERIOR SHEATHING (E) BUILDING PAPER (E) STUCCO TO REMAIN 1 Imo �I x hud WINDOW HEAD (E) GWB (E) WD. JAMB LINING. TO REMAIN WOOD TRIM, FINISH TO MATCH (E) WOOD BLOCKING PER Z -BAR FRAME INSTALLATION SEALANT STUCCO FIN BEHIND (E) LATH BACKER ROD I SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT STUCCO FIN BEHIND (E) LATH WINDOW NAIL FLANGE (E) STUCCO TO REMAIN (E) BUILDING PAPER (E) EXTERIOR SHEATHING WINDOW JAMB 0 WINDOW SILL (E) GWB WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM BACKER ROD 4 SEALANT 1X WOOD LEDGER SEALANT BED SEALANT I BACKER ROD 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM lx WOOD LEDGER SEALANT BED (E) GWB STUCCO - WINDOW DETAIL SET 3" = 1' - 0" TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 0S800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. MAR 1 21012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 032011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMIT CENTER • S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • PAK (206) 624 -2973 COTT ,STATE OF 0810.03.1841 2/24/I1 F- O J z O Q z w F z z 0 0 0 AIP NUMBER MPROVEMENTS w 2 w w 0 z LL U OC a 5- 53- 0058 -043 DATE ISSUED 2/24/11 BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1841 DOOR TYPES 0 A FLUSH 5CW W/ WAGON WHEEL AND 4 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT EXTERIOR SINGLE LEAF STORM WI SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET / FINISH KNOB / LEVER SET LOCK SET DETAIL SET I ENTRY A 3' -0" x 6' -8" STAIN /STAIN 14W -I / 626 DK -2 LOCK -I 1 /A2.1 2 ENTRY B 3' -0" x 6' -8" I /A2.1 (E) STUCCO TO REMAIN BACKER ROD AND SEALANT PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED N THE FIELD CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE 2" MIN. (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE DOOR HEAD BACKER ROD AND SEALANT CONTINUOUS SEALANT BEHIND Z BAR FRAME STOW' DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING JAMB BEYOND DOOR JAMB WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP ALUMINUM THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE se DOOR SILL (E) EXTERIOR PLYWOOD EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR PER SCHEDULE STUCCO - DOOR DETAIL SET 3 " =1' -0" 174\ TYPICAL DOOR SCHEDULE NOTES L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. EXPIRED MAR 1 22012 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JUL 19 2011 PERMITCENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (208) 624 -2973 REGISTERED Ac ,HITE:CT 2/24/11 0810.03.1841 H ce O a J Z 0 z w z z 0 U 0 Z MPROVEMENTS D ce W W W 0 Zce ce H AIP NUMBER 5- 53- 0058 -043 z O 0 z_ DATE 2/24111 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1841 MAR 1 2012 (E) STUCCO TO REMAIN SACKER ROD 4 SEALANT (E) WALL UNDERLAYMENT SELF ADHERING BITUMINOUS MEMBRANE FLASHING PRE- PRIMED, GALV SWEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. SET IN MASTIC AT EXTERIOR TRIM. PRE- PRIMED, GALV SHEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD BACKER ROD 4 SEALANT (E) STUCCO TO REMAIN (E) EXTERIOR PLYWOOD (E) EXTERIOR SHEATHING 2X2 BLOCKING, 4 SIDES (P.T.) AIR INTAKE DETAIL AT EXTERIOR 3" = 1' - 0" SUSPEND MECH UNITS FROM (E) STRUCTURE RE: MECHANICAL MECH UNIT AND DUCTS - REF MECHANICAL CONTINUOUS VIBRATION DAMPENING PAD RE: MECHANICAL EXISTING CEILING STRUCTURE ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL CONTRACTOR AND FIELD CONDITIONS WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS a 16" O .C. 5/5" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 2x2 CONT. NAILER 12 "XI6" ACCESS HATCH FOR MAINTENANCE BLENDING AIR UNIT ACCESS PANEL 11/2 " =1' -0" SOFFIT DETAIL REVIEWED FOR CODE COMPLIANCE APPROVED AUG 0 3 2011 City of Tukwila BUILDING DIVISION ATTACH 2x3 LEDGER TO EXIST. PECK ATTACH SOFFIT FRAMING TO LEDGER COAT 1 " x 1" WD BLOCKING WI ADHESIVE AND INSERT AT (E) GWB PANEL EDGE. PROVIDE FINISH -GRADE PAINTABLE GWB EDGE AND CAULK JOINT DUCTS PER PLAN WITHIN SOFFIT WHERE WIDTH OF SOFFIT EXCEEDS 16 ", PROVIDE 2x2 SOFFIT FRAMING ® 16" O.C. 2x2 CONT. NAILER %" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. 1 1/2" = 1' - 0" MATCH EXIST. SOFFIT HT. RECEIVED JUL 19 2011 PERMIT CENTER S.MSTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 REGISTERED A,H[TE_CT 0810.03.1841 2/24/11 MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH MISC. DETAILS A2.2 0810.03.1841 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTU H CD CFM CI RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR Ao XX OR XX 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 6. 7. 8. 10. 11. 12. SYMBOL SG ABBR f + S'Em-mA.0 .4+ x + f + -el- el-- (ZOR EQUIP ID# . NG • O 0 D'4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT VD RA /EA RG SA SA RA /EA SD DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 4" 4" X DECO 1, 2, 3 X REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 1,2 - SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 165 .5" WG 32 "Lx12.25 "Wx8.5 "H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 165 <.08" WG 8" 8" WALL DECO 1, 2, 3 OG -1 90 <.08" WG 7» 7" WALL WALL CAP 1, 2, 3, 4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 3 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1841 875 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION I MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. EXpi MAR 1 2 2012 ED THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / ( &EGR X F) QR = (FROM TABLE 403.8.1) 5 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/1. QF = 45 / (1 X 1/2) = 90 CFM RECEIVED JUL 19 2011 PERMIT CENTER SEPARATE PERM AND APPROVAL REQUIRED EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited liability company 4000 DELRIDGE WAY SW SU1T11 200 • SEATIL6, WA 98106 (20e) 624 -8777 • FAX (206) 1124 -2973 THE GREENBUSCH GROUP, INC .....ai...) ADOIISIN'N, N1d0_/ VDED 3 YECIMNGIL ENOtEE116 1006 !ESL. sir BUBE 901 9FARE, 00110 (206) 378 -0309 (206) 378 -0641 FAX 0810.03.1841 KING COUNTY INTERNATIONAL AIRPORT U) 0 0 2 0 w w ce w O z Q w AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M1.0 0810.03.1841 SOFFIT BY OTHERS 7"o 410 /BEDROOM EU- 25 UNIT D SOFFIT BY OTHERS Ba II 25 BEDROOM 6"� 2 Agh M2.0 8"d BATH SEE KITCI4EN LAUNDRY MAIN FLOOR MECHANICAL PLAN INSTALL PER THE MANUFACTURER'S WRITTEN INSTRUCTIONS OUTSIDE AIR DUCT 16" MIN RETURN AIR DUCT FILTERS ACCESS MOTOR ACCESS HOLD TIGHT TO STRUCTURE COORDINATE ACCESS HATCH FOR ELECTRIC AND MAINTENANCE ACCESS WITH TECHNIC L REPRESENTATIVE SOFFIT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSULATE ALL DUCT AS SCHEDULED. BLENDING UNIT INSTALLATION DETAIL NONE 4"0 4, 1 65 SEE uo n TYP ALL WALL GRILLES NORTH B25 ] LIVING ROOM B DROOM 3 SHEETMETAL TRANSITION TO GRILLE NECK SIZE CAULK FOAM BACKER ROD WALL CAP OR SIDEWALL GRILLE DUCT PER PLAN SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP INSTALLATION DETAIL 3 NONE SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. FLAG NOTES: BV -1 AND DUCTWORK ROUTED IN SOFFIT. COORDINATE MAINTENANCE HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCTS AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. DUCT PER PLAN EX RED MAR 1 2 2012 1c)\\Mg CAULK FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. CEILING GRILLE INSTALLATION DETAIL NONE SEPARATE p� PERMIT APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS • Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 98106 (806) 624-2777 • FAX (206) E24 -8979 THE GREENBUSCH GROUP, INC ••••011111101111))) AMID NRE) 8 IEDWICIIL OIA111519 1909 11881 SIIiEr 9UIE ffi1 gRl11Fi. it 11!1114 (206) 378 -0569 (209) 378-0941 FAX 0810.03.1841 KING COUNTY INTERNATIONAL AIRPORT AIP NUMBER 5 -53 -0058 -043 SEATTLE WASHINGTON DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1841 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE UMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION. PAINT TO MATCH SURROUNDING CONDITIONS. ELECTRICAL PLAN NOTES C : PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS. O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE. 03 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. PANEL MP LOCATION: SERVING: 0810.03.1841 SYMBOL 10,000 120/240 VOLT, 1 PHASE, 3 WIRE. BKR G RESIDENCE AIC, 100 AMP with MAIN BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 1 1 1 1 1 1 4 CKT LOAD DESCRIPTION TYPE KVA A/P I= NP KVA TYPE LOAD DESCRIPTION CKT 1 3 EXISTING LOAD ELECTRICAL METER 40/2 A 30/2 AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. TO EXISTING LOAD 2 4 5 EXISTING LOAD X 30/2 A ■ 20/1 1 EXISTING LOAD 6 7 9 11 SPACE PHASE LOAD PHASE A= KVA, PHASE B= 20/2 #VALUE+, A KVA. B B 15/1 15/1 2011' REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH EXISTING LOAD BLENDING UNIT 8 10 12 LOAD TYPE L R M H WH D A K LM TOTAL LOADS CONN. LOAD KVA AMP COMPUTED LOAD KVA AMP ❑ ISOLATED GROUND BUS ❑ RAINTIGHT NEMA -3R ENCLOSURE FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH ■ ❑ REMARKS: ** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM. ELECTRICAL LEGENID SYMBOL PESCRIPtION SYMBOL DESCRIPTION FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION G LIGHTING OR POWER PANEL PH EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. 15 1 1 1 1 1 1 4 DAMPER CONNECTION D' NON -FUSED DISCONNECT SWITCH 0 MAST, WEATHERHEAD 0' TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS 120 BRANCH CIRCUIT HOME RUN RUN frg1 SMOKE DETECTOR EJ ELECTRICAL METER i 11MER OPERATED SWITCH 1,2 AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY. TO THERMOSTAT - - - X X MECLANICAL / ELECTRICAL COOS «NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION NSTALLED UNDER DIVISION WIRED UNDER DIVISION DESCRIPTION VOLTS PH 15 16 15 16 N/A 15 16 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X X X 1,2 - SWITCHES (ON, 11MER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH MAR 1 2 2012 vi01 -2-� UNITD SE D IROOM 1 KITCHEN LAUNDRY 5EDROOM 3 LIVING ROOM SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED JUL 19 2011 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 EN•INE!NI, INO IMO Baru 41111. 111111M wn..N MOM WA 11141111411111111 M..ua. NOM ORS IVIK Mew NS Mr 0810.03.1841 F- 0 0 J z 0 F- Q LL w I- z z O U 0 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 F- 0 z F- t- DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1841