HomeMy WebLinkAboutPermit D11-236 - RUSSELL FOUR-PLEX - UPGRADESRUSSELL 4 -PLEX
11602 42 AV S
EXPIRED 03-1 2-1 2
D11 -236
City ("Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 3347400070
Address: 11602 42 AV S TUKW
Suite No:
Project Name: RUSSELL 4 -PLEX
DEVELOPMENT PERMIT
Permit Number: D11 -236
Issue Date: 09/14/2011
Permit Expires On: 03/12/2012
Owner:
Name: RUSSELL WILLIAM P
Address: 2801 S 128TH ST #100 , TUKWILA WA 98168
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: TRON CONSTRUCTION INC
Address: 2845 N MAROA AV , FRESNO CA 93704
Contractor License No: TRONCCI9190A
Phone: 206 - 296 -7437
Phone: 559 559 -7992
Expiration Date: 09/01/2013
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $53,581.00 Fees Collected: $1,652.19
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
* *continued on next page **
doc: IBC -7/10
D11 -236 Printed: 09 -14 -2011
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
N
N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Number: 0 Size (Inches): 0
Start Time:
Volumes: Cut 0 c.y.
End Time:
Fill 0 c.y.
Start Time: End Time:
Private:
Profit: N
Private:
Date:
Public:
Non - Profit: N
Public:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pr
construction or the performance of work.
to this permit.
Signature:
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this development permit and agree to the conditions attached
Date: / / /y /lJ
Print Name: 1645 h 4A7E
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D11-236 Printed: 09 -14 -2011
this requirement.
0 4
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431- 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D11 -236 Printed: 09 -14 -2011
CITY OF TUKWIL
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No b IA ,.. 2...3
Mechanical Permit No
Plumbing /Gas Permit No
Public Works Permit No
Project No.
(For office use only)
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 4201 S. 116th St.
King Co Assessor's Tax No.: 3347400070
Suite Number: Floor:
New Tenant: ❑ Yes 10 ..No
Tenant Name: William P. Russell
Property Owners Name: William P. Russell
Mailing Address: 4201 S. 116th St.
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296 -7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker @kingcounty.gov
City State
Fax Number: (206) 269 -7315
Zip
GENERAL CONTRACTOR INFORMATION -
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
City
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
State
Zip
ARCHITECT OF RECORD All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Melody Leung or Timothy Fenlason
E -Mail Address: melody @smstemper.com or tim @smstemper.com
City State
Day Telephone: (206) 624 -2777
Fax Number: (206) 624 -2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
H: \Applications\Forms- Applications On Line\2009 Applications \1 -2009 - Permit Application.doc
Revised: 1 -2009
bh
State
Zip
Page 1 of 6
BUILDING PERMIT INFORM PION - 206 -431 -3670
Valuation of Project (contractor's bid price): $ 53,581 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
0.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:'Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
1° Floor
1,940
rd Floor
1,075
3r° Floor
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard:
Compact: Handicap:
Will there be a change in use? ❑ Yes 0 No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No
If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:'Applications\Forms- Applications On Line\2009 Applications \1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Oft
PLUMBING AND GAS PIPING 2ERMIT INFORMATION - 206 -43 70
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water: Sewer:
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
Clothes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and /or vent
Industrial waste treatment
interceptor, including trap
and vent, except for kitchen
type_grease interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen ( >750
gallon capacity)
Repair or alteration of
water piping and/or water
treatment equipment
Repair or alteration of
drainage or vent piping
Medical gas piping
system serving 1 -5
inlets /outlets for a
specific gas
Each additional medical
gas inlets /outlets greater
than 5
Backflow protective
device other than
atmospheric -type vacuum
breakers 2 inch (51 mm)
diameter or smaller
Backflow protective device
other than atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1 -5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H:Wpplications\Forms- Applications On- Line\2009 Applications \I -2009 Permit Application.doc
Revised. 1 -2009
bh
Page 5 of 6
PERMIT APPLICATION NOTES— Applicable to all permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature: Date:
Print Name: Timothy J. Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624 -2777
Seattle
Mailing Address: 4000 Delridge Way SW, Suite 200
WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires: 1~ 1
--rte
Staff Initials:
H ^Applications\Forms- Applications On Line\2009 Applications \I-2009 - Permit Application doc
Revised, 1 -2009
bh
Page 6 of 6
CitOof Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 07 -28 -2011 at 11:16:08 07/28/2011
RECEIPT NO: R11 -01600
Initials: WER
Payment Date: 07/28/2011
User ID: 1655 Total Payment: 13,064.48
Payee: PAMELA K KUEHL
SET ID: 071911 SET NAME: KING COUNTY HOUSING
SET TRANSACTIONS:
Set Member Amount
D11 -222 748.15
D11 -223 716.64
D11 -224 1,092.10
D11 -225 993.76
D11 -226 622.10
D11 -227 653.61
D11 -228 1,067.51
D11 -229 685.13
D11 -230 685.13
D11 -231 716.64
D11 -232 1,018.34
D11 -233 559.07
D11 -234 811.18
D11 -235 1,042.93
D11 -236 1,652.19
TOTAL:
TRANSACTION LIST:
Type Method Description Amount
Payment Credit C VISA 13,064.48
TOTAL: 13,064.48
ACCOUNT ITEM ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
PLAN CHECK - RES
STATE BUILDING SURCHARGE
000.322.100 7,876.95
000.345.830 5,120.03
640.237.114 67.50
TOTAL: 13,064.48
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit No. D11 -236
RUSSELL 4 -PLEX
11602 42 AV S TUKW
Dear Permit Holder:
In reviewing our current records, the above noted permit has not received a final inspection by the City of
Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform
Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the
provisions of these codes shall expire by limitation and become null and void if the building or work authorized
by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 03/12/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final
inspection. Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is
due to expire. Address your extension request to the Building Official and state your reason(s) for
the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is
determined that your extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and /or receive an extension prior to 03/12/2012, your permit will
become null and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall
t Technician
File: Permit File No. Dl 1 -236
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: D11 -236
PROJECT NAME: RUSSELL 4 -PLEX
SITE ADDRESS: 11602 42 AV S
X Original Plan Submittal
Response to Correction Letter #
DATE: 07 -19 -11
Response to Incomplete Letter #
Revision # After Permit Issued
EPARTMENTS:
Bikw' ing Division
I� o 1-
Public Works
u
l�w� ►��� 01‘15C'11
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete ❑
DUE DATE: 07 -21 -11
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route NIX Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved
Notation:
n
Approved with Conditions
DUE DATE: 08-18 -11
Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Printer Friendly Page
•
•
General /Specialty Contractor
A business registered as a construction contractor with L &I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name TRON CONSTRUCTION INC UBI No. 602940001
Phone 5592297992 Status Active
Address 2845 N Maroa Ave License No. TRONCCI9190A
Suite /Apt. License Type Construction Contractor
City Fresno Effective Date 9/1/2009
State CA Expiration Date 9/1/2013
Zip 93704 Suspend Date
County Out Of State Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
DONALDSON, RON ARDEN
President
09/01/2009
Amount
DONALDSON, SHARYN
Secretary
09/01/2009
LHA135245
DONALD, SHARYN
Treasurer
09/01/2009
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
OLD REPUBLIC
SURETY CO
WCL1256498
09/01/2009
Until Cancelled
$12,000.00
08/05/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
3
American Ins Co Landmark
American
LHA135245
03/01/2011
03/01/2012
$1,000,000.00
03/07/2011
2
LANDMARK
AMERICAN INS
CO
LHA134615
03/01/2010
03/01/2011
$1,000,000.0003
/10/2010
1
LANDMARK
AMERICAN INS
CO
LHA133917
03/01/2009
03/01/2010
$1,000,000.00
08/05/2009
Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
https: // fortress .wa.gov /lni/bbip/Print.aspx 09/14/2011
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
AS Ilk
City of Tukwila
BUILDING DIVISION]
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00625C11 BID PACKAGE M -24
5- 53- 0058 -043
SEPARATE PERMIT
REQUIRED FOR:
C Mechanical
gitiectricai
efflumbing
Gas Piping
City of Tukwila
OI N�; DIVISION
MAR ,1 .2 2012
FILE' COPY
Permit No. D i v- 23(p
Plr.T review approval is subject to errors and omissions.
A ;:i o al of construction documents does not authorize
th`: violation of any ado e or ordinance. Receipt
of approved Field 's acknowledged:
By
Date: 7 9'%fh
City Of 1Ukwiia
BUILDING DIVISION
PRIOR TO COMMENCING WITH
DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
For alb
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
Fs visions will require a new plan submittal
ah, may inc:ude additional plan review fetes. I
SITE AND BUILDING INFORMATION
JURISDICTION:
Department of Planning and Development
City of Tukwila, WA
APPLICABLE CODES:
2009 International Residential Code,
International Fire Code,
international Mechanical Code
3341400010
LEGAL DESCRIPTION:
HILLMANS MEADOW GARDENS DIV • I
ZONING: SF1200
OCCUPANCY: (No Change)
SINGLE FAMILY RESIDENCE
CONSTi,JCTION TYPE: (No Chance)
V B NON SPRINKLERED
DUILDING AREA:
No change to building footprint.
Addition:.
Remodel:
Sound Insulation:
DRAWING INDEX
T0.0 TITLE SHEET, PROJECT INFO.
41.0 FLOOR PLANS 4 NOTES
42.0 WINDOW TYPES, SCHE=DULE 4 DETAILS
42.1 DOOR TYPES, SCHEDULE 4 DETAILS
422 MISCELLANEOUS DETAILS
42.3 WINDOW FLASHING DETAILS
111.0 LEGENDS, SCI- IEDULES, ABBREV., GENERAL NOTES 4 DUJG INDEX
M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS
Et0 FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
1211 Perimeter Road South
Seattle WA 98108
Ph: 206. 263. 9233
Fax: 206.296. 0190
Contact: Sharyn Parker
E -mail: Sharyn.Parkerekingcounty.gov
ARCHITECT:
S.M. Stemper Architects PL.L.C.
4000 Delridge Way SW, Suite 200
Seattle, WA 98106
Ph: 206. 624.2111
Fax: 206.624.2913
Contact: Jerry Osborn, Melody Leung,
Tim Fenlason,
E -mail: Jerryesmstemper.com
melodyesmetemper.com
timeemstemper.com
ACOUSTICAL ENGINEER:
SSA Acoustics
222 Etruria Street, Suite 100
Seattle WA 98109
Ph: 206. 839. 0819
Fax: 206.839.0824
Contact: Mohamed Alt Allaoua
E -mail: mohamedeesaacoustica.com
MECHANICAL ENGINEER:
The Greenbusch Group
1900 West Nickerson St, Suite 201
Seattle, WA 98115
Ph: 206. 318. 0569
Fax: 206.318.0641
Contact: Chris Ager
E -mail: ChrisAegreenbuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 S. 42nd Street, Suite 301
Tacoma, WA 98409
Ph: 253. 412. 3300
Fax: 253.412.3463
Contact: Brent Rollins
E -mail: bcretreswest.com
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E., Suite 100
Seattle, WA 98102
Ph: 206. 232. 9639
Fax: 206.162.4180
Contact: Tim Ogden
E -mail: tim ogdenepbsenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. 4200
Boston, MA 02114
Contact: Tim Feniason/ Jim Cornwell
E -mail: JCornwellejonespayne.com
RECEIVED
JUL 19 2011
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824 -2777 • FAX (20B) 824 -2973
4220
SCOTT I
srATE< OF
0810.03.1838
TENOE
3RN(,TON
2/24/11
ce
0
0
ct
>-
Q
LLI
O
Et
� W
Z W
ce
Z
z 0
0 —i
Z
W
0
C/)
W
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
PROJECT
INFORMATION,
DRAWING
INDEX,
VICINITY MAP
DIRECTORY
T0.0
081 0.03.1 838
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
NE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 020S1 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
�U
V
5 E. 0 ROOM
efEDi" Oc 1"1
2
?A°-4
L�
r T GPI -1%
LIVING
ROOM
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
I. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO S•.00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
Z. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
S. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
I1. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR. THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A10 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET EIS FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM DOVER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5 :00 PM.
I. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
IS. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
UNIT A
a:
MAIN FLOOR PLAN
1/4" = 1'
Li
LI VFW
ROOM
LLa I E�J Ja,t -a
�I
1'
OCA-
7 ..L_� -_J�
II�
5A", H
PLAN KEYNOTES
ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0
2 O DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET A2.I
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REEF. ELECT. FOR 5PEE0
CONTROL AND DISCONNECT. REF. 1/A22 FOR PETAL.
OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION
DETAIL.
OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
ACCESS TO SITE AND PARKING
I. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO I- IMEOUNER DRIVEWAY.
0
UNIT
3I D ROOM
r
E<
DP. Oi"f
2
LEGEND
I•
i
J
\-2Ap
I
ACOUSTICAL WINDOW
NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.I
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
A. NORTH ELEVATION
B. EAST ELEVATION
C. EAST ELEVATION
D. SOUTH ELEVATION
E. WEST ELEVATION
WALL GRILL
IGAS
NOT USED
MAR .12'2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
INSTALL BATTERY OPERATED SMOKE
DETECTORS
NOT USED
GAS METER
RECEIVED
JUL 19 2011
P`.oe .TCENTEP.
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1838
2/24/11
—J
.e�
z
0
z
w
z
KING COUNTY
MPROVEMENTS
a
w
w
ct
w
0
z
IL
U
ce
co
ct
AIP NUMBER
5 -53- 0058 -043
z
0
F-
z
w
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1838
WINDOW TYPES
SINGLE HUNG
2
CASEMENT
•
3
SLIDER/ FIXED/ SLIDER
4
CASEMENT/ FIXED
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
BEDROOM I
2
2' -10" x 3' -10"
STAIN/PAINT
SAFETY GLAZING REQUIRED
Y
1/A2.0
B
BEDROOM I
I
5' -10" x 1' -I0"
STAIN/PAINT
I /A2.0
C
BEDROOM 2
I
5' -10" x 1' -I0"
STAIN/PAINT
I /A2.0
D
BEDROOM 2
2
2' -I0" x 3' -10"
STAIN/PAINT
Y
I /A2.0
E
KITCHEN
I
2' -0" x 2' -10"
STAIN/PAINT
I /A2.0
F
LAUNDRY ROOM
3
5' -4" x 4' -4"
STAIN/PAINT
SAFETY GLAZING REGURED
I /42.0
G
LIVING ROOM
4
4' -4" x 3' -10"
STAIN/PAINT
SAFETY GLAZING REQUIRED
1/42.0
(E) = EXISTING
(E) STUCCO
(E) STUCCO UNDERLAYMENT
SEALANT
COUNTERSINK SCREWS AND
FILL HOLES TYP.
(E) EXTERIOR SHEATHING
NEW STUCCO PATCH, MAINTAIN WIRE MESH
REINFORCEMENT.
STUCCO DRIP SCREED
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
SACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
MANUFACTURED Z -BAR FRAME
ACCOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) STUCCO TO REMAIN
STUCCO FIN BEHIND (E) LATH
211
WINDOW HEAD
(E) GWB
(E) WD. JAMB LINING. TO
REMAIN
WOOD TRIM, FINISH TO MATCH
WOOD BLOCKING PER
Z -BAR FRAME
INSTALLATION
SEALANT
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
STUCCO FIN BEHIND (E) LATH
WINDOW NAIL FLANGE
(E) STUCCO TO REMAIN
(E) BUILDING PAPER
(E) EXTERIOR SHEATHING
WINDOW JAMB
0
WINDOW SILL
(E) GWB
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
BACKER ROD 4 SEALANT
IX WOOD LEDGER
SEALANT BED
SEALANT 4 BACKER ROD
3/4" WD. SILL - STAIN
TO MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
IX WOOD LEDGER
SEALANT BED
(E) GWB
STUCCO - WINDOW DETAIL SET
3" = 1' - 0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
VI— 2.3(e
EXP
MAR ,12 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 192011
PERMIT CENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
COTT T.EMPE
STATE OF HINGTON'
0810.03.1838
2/24/11
H
O
a
Q J
Z
0
z
w
H
z
z
0
U
0
Z
MPROVEMENTS
D
W
W
W
0
H
U
Q
J
Q
Z
W
co
D
W
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1838
DOOR TYPES
®,®
0
,4
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
EXTERIOR SINGLE LEAF
STORM W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
3' -0" x 6' -8"
STAIN/STAIN
1-1W-1/ 626
DK -2
LOCK -1
1/42.1
2
LAUNDRY ROOM
A
2' -S" x 6' -S"
STAIN/STAIN
HW —I / 626
DK -2
LOCK -1
I /42.1
3
ENTRY
5
3' -0" x 6' —S"
I /42.1
4
LAUNDRY ROOM
B
2' —S" x 6' -S"
1/42.1
(E) STUCCO TO REMAIN
BACKER ROD AND SEALANT
PRE— PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MN.
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
LATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
BACKER ROD AND SEALANT
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KEW AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MN.
AUTOMATIC DOOR SWEEP
ALUMNUM THRESHOLD
ADJUSTABLE SWEEP
DOOR JAMB
EXISTING FLOOR STRUCTURE
0
DOOR SILL
STUCCO - DOOR DETAIL SET
(E) EXTERIOR PLYWOOD
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
3 "= 1' -0"
TYPICAL DOOR SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS N THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
EXPI ` ED
MAR 1 2 2011
III -2,5e
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELEIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
COTT
STATE OF
0810.03.1838
TEMPE:
.aHINGTON
2/24/11
0
0
ce
J
z
0
z
c
w
1—
z
z
0
U
z
MPROVEMENTS
AIP NUMBER
5- 53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1838
(E) STUCCO TO REMAIN
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
SACKER ROD 4 SEALANT
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT NTERIOR WI
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN NE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
(E) EXTERIOR SHEATHING
2X2 BLOCKING, 4 SIPES
(PT.)
AIR INTAKE DETAIL AT EXTERIOR
3 "= 1' -0"
I --2_,;(R
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
WHERE WIDTH OF SOFFIT EXCEEDS
n 16 ", INSTALL 2X4 STUDS * 16" O.C.
5 /S" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
2x2 CONT. NAILER
12"X16" ACCESS HATCH
FOR MAINTENANCE
BLENDING AIR UNIT ACCESS PANEL
1 1/2"=1'-O "
EXISTING
CEILING
STRUCTURE
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE W/ ADJ.
ARCHITECTURAL FEATURES PER
PLAN. COORDINATE SOFFIT
DIMENSIONS WITH MECHANICAL
CONTRACTOR AND FIELD
CONDITIONS
SOFFIT DETAIL
EX MED
MAR 1 2 2011
ATTACH 2x3 LEDGER TO EXIST. DECK
ATTACH SOFFIT FRAMING: TO LEDGER.
COAT)" x 1" WD BLOCKING W/
ADHESIVE AND INSERT AT (E) GWS
PANEL EDGE.
PROVIDE FINISH -GRADE PAINTABLE
GM EDGE AND CAULK JOINT
DUCTS PER PLAN WITHIN SOFFIT
WHERE WIDTH OF SOFFIT EXCEEDS I6 ",
PROVIDE 2x2 SOFFIT FRAMING ® 16" O.
2x2 CONT. NAILER
8" GWS- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
1 1 /2" = 1' - 0"
MATCH EXIST. SOFFIT HT.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
•
S.M.STEMPER
ARCHITECTS
A Profeaeional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(208) 624 -2777 • FAX (208) 824 -2973
REGISTERED
HITE:CT
GOTT 4TEMPE •
STATE OF SHINGTON
0810.03.1838
2/24/11
0
0
J
<
�
Q
O w ix
Z
U1 O
H Z
z �
gll-
Z
O
U <
0 --I
Z Q
z
w
0
w
ce
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
Z
O
H
0
z
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1838
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASH RAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEIUNG
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEIUNG DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL ABBR
XX
OR XX
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
0 ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
ED
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
SG -X
XXX
4- I DN I IF
up I
f t
+ f +
■
DN
UP
VD
RA /EA
RG
SA
SA
-el- 0-1- RA /EA
CjZOR
EQUIP ID#
.l:
171
SD
EA
MOD
NG NG
•
0
D'a
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
<.08" WG
8"
8"
WALL
DECO
1, 2, 3
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
WALL
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1838
602
2
90 CFM
90 CFM
IN CEMENT SLAB OR IN GROUND
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION I MIN VALUE INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
MAR .1 .22011
III-- 23(a
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) la
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION la.
QF = 45 / (1 X 1/2) = 90 CFM
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Professional Tinned liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (20e) 624 -2073
THE GREENBUSCH GROUP, INC
)))
NYIIO Z tit 201 MI. E.INEa010
Tarn �r sir s6� MOUE. IN 1111110
(206) 378 -0660 (206) 376 -0641 FAX
0810.03.1838
KING COUNTY INTERNATIONAL AIRPORT
F-
z
w
ME
0
w
0
a
w
w
w
O
z
F-
w
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1838
BEDROOM
2
SEE M2 O TYP ALL
WALL GRILLES
SOFFIT BY
OTHERS
BV -1 LOCATED IN
CLOSET SOFFIT
BEDROOM
UNIT A
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
CLOSET
SOFFIT
COORDINATE ACCESS
HATCH FOR ELECTRICA
AND MAINTENANCE
ACCESS MN TECHNIC L
REPRESENTATIVE
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
KITCHEN
LIVING
ROOM
NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
2. HEATING IS PROVIDED BY ELECTRIC UNIT
HEATERS.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN SOFFIT.
COORDINATE MAINTENANCE HATCH WITH
TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO NE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
2.(p
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE INSTALLATION DETAIL
4
() NONE
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
�D
MAR 1.2 2011
RECEIVED
JUL 19 2011
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Proferdo eal Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200• SEATTLE, RA 98106
(20e) e24 -2777 • FAX (200) 024 -297'
THE GREENBUSCH GROUP, INC
10102101/ DINNEBI
)))
1 MlaON SIREN CIE 201 t 9
(200) 378 -0589 (200) 378-0541 FM
0810.03.1838
KING COUNTY INTERNATIONAL AIRPORT
i-
z
w
w
0
Elf
0
w
w
w
O
z
LL
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1838
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5: 00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
PANEL
MP
LOCATION:
SERVING:
0810.03.1838
SYMEOL
10,000
120!240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
RESIDENCE
AIC,
100
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
I I I
CKT
LOAD DESCRIPTION
TYPE
KVA
APP
PHASE]
A"P
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
EXISTING LOAD
—�-
E3
40/2
A
B
30/2
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY.
EXISTING LOAD
2
4
5
EXISTING LOAD
20/2
A
30/2
EXISTING LOAD
6
7
9
11
SPACE
SPACE
SPACE
PHASE LOAD PHASE A=
KVA
PHASE B=
2011
1511
#VALUE!
A
KVA.
B
B
1511
20/1"
EXISTING LOAD
BLENDING UNIT
8
10
12
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS
❑ RAINTIGHT NEMA-3R ENCLOSURE ❑ DOUBLE LUGS
MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE
SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH
1
❑
REMARKS:
** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM.
ELEcTRIcAL LEGEND
SYMBOL
DESCRIPTION
SYMEOL
DESCRIPTION
G
UGHIING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
I I I
1
9
DAMPER CONNECTION
❑'
NON- FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
❑S'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
OD
SMOKE DETECTOR
—�-
E3
ELECTRICAL METER
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY.
TO
THERMOSTAT
— - —
1IEci- IANIcAL ! ELEcTIRIcAL cooRD IN4TION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15
16
N/A
15
16
N/A
REMARKS
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
5E D ROOM
2
SEDROOM
MP /12
15ATI -1
LAUNDRY'
MAR 1.2 2012
ED
0810.13.1838 UNIT A
EXISTING ELECTRICAL PANEL
KITCI -1N
LIVING
ROOM
KITCHEN
LIVING
ROOM
NORTH
15ATH
SEDIROOM
5EDF
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
ENGINEERS, INC
IRS MINH 4/110 Smr. 111111 wr
7M9oIK WA oNSN •TSN
MINIM IMP NB tasa
I $asaa«.
0810.03.1838
0
IZ
-J
z
0
F-
z
LLI
F-
z
z
0
U
0
z
AIP NUMBER
MPROVEMENTS
D
W
W
W
0
Ct
z
D
5 -53- 0058 -043
z.
0
F-
0
z_
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1838
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT I5 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
>e
MATH
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5 :00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL WAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT SE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
8. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS I SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQD MD RE- CONSTRUCT
SHELVING IN COORDINATION WIN SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMI9"I POUER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. I AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
UNIT A
2
L4UNL)
1
KITCHEN
LIVINcix
ROOM
1t
UNIT 1 7 v
r�
L, I VINE
ROOM
T
I
MAIN FLOOR PLAN
1/4" = 1'
UNIT 5
E
MAR 12'Z011
PLAN KEYNOTES
OI DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, MD THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON 5HEET A2.1
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
OBLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED
CONTROL AND DISCONNECT. REF. 2/A22 FOR DETAIL.
OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION
DETAIL.
OINSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
1:") \ 1 ..... 2:0000b(„
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
NORTH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
A. NORTH ELEVATION
B. EAST ELEVATION
C. EAST ELEVATION
D. SOUTH ELEVATION
E. WEST ELEVATION
LEGEND
f I ACOUSTICAL WINDOW
NOT USED
EXTERIOR STORM DOOR
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.1
O SEE WINDOW SCHEDULE FOR
WINDOW TYPES
T
/ E
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
WALL GRILL
NOT USED
ATTIC INSULATION
RECEIVED
JUL 19 2011
TC
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
I, I
NOT USED
GAS METER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAK (206) 824 -2973
REGISTERED
A` HITE.CT
0810.03.1839
TEMPE
i+SHINGTON
2/24/11
�C
0
a_
J
z
O
I—
z
w
H
z
z
0
U
0
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1839
WINDOW TYPES
FIXED
U/ OBSCURE SAFETY
GLAZING
2
CASEMENT
2i0" MIN_
3
SLIDER/ FIXED /SLIDER
4
CASEMENT/ FIXED
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
LIVING ROOM
1
1' -0" x 6' -6"
STAIN/PAINT
1/42.0
B
LIVING ROOM
4
4' -4" x 3' -10"
STAIN/PAINT
1/A2,0
c
BEDROOM 1
3
5' -I0" x I' -10°
STAIN/PAINT
CUT SILL TO 40" AFF FOR EGRESS (E) HT. 55"
y
1/42.0
0
BEDROOM 2
3
5' -I0" x I' -10"
STAIN/PAINT
1/42.0
E
BEDROOM 2
2
2' -10" x 3' -10"
STAIN/PAINT
Y
1/42.0
(E) • EXISTING
(E) STUCCO
(E) STUCCO UNDERLAYMENT
SEALANT
COUNTERSINK SCREWS AND
FILL HOLES TYP.
(E) EXTERIOR SHEATHING
NEW STUCCO PATCH, MAINTAIN WIRE MESH
REINFORCEMENT.
STUCCO DRIP SCREED
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE HELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
MANUFACTURED Z -BAR FRAME
ACCOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) STUCCO TO REMAIN
STUCCO FIN BEHIND (E) LATH
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOU ASSEMBLY
BACKER ROD t SEALANT
WINDOW HEAD
,J11
tyl■
1L
WINDOW JAMB
STUCCO FIN BEHIND (E) LATH
WINDOW NAIL FLANGE
(E) STUCCO TO REMAIN
(E) BUILDING PAPER
(E) EXTERIOR SHEATHING
0
WINDOW SILL
(E) GWB
(E) WD. JAMB LINING. TO
REMAIN
WOOD TRIM, FINISH TO MATC
WOOD BLOCKING PER
Z -BAR FRAME
INSTALLATION
SEALANT
(E)G
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
BACKER ROD 4 SEALANT
IX WOOD LEDGER
SEALANT BED
SEALANT 4 BACKER ROD
3/4" WD. SILL - STAIN
TO MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
IX WOOD LEDGER
SEALANT BED
(E) GWB
STUCCO - WINDOW DETAIL SET
3 " =1' -0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 0SS00 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
EXPI
MAR 12'2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
JERM1TCENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
RE.GI < =rERED
�,TTlllP 'i,...:TurrECT Y'... ,.
COTT TEPE
STATE OF r HINGTON
2/24/11
0810.03.1839
H
O
CL
J
Z
O
z
w
F-
z
z
0
U
0
Z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
0
z
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
A A, LB &J H
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
081 0.03.1839
DOOR TYPES
Oik
O
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
EXTERIOR
SINGLE LEAF STORM
ID/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
3' -0" x 6' -S"
STAIN/STAIN
14-1 / 626
DK -2
LOCK -I
1 /A2.1
2
ENTRY
B
3' -0" x 6' -S"
1 /A2.1
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN NE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
BACKER ROD AND SEALANT
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER - STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
2" MIN.
DOOR JAMB
EXISTING FLOOR STRUCTURE
0
DOOR SILL
STUCCO - DOOR DETAIL SET
(E) EXTERIOR PLYWOOD
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP WI BATT
INSULATION
DOOR PER SCHEDULE
3 "= 1' -0"
EXPI': ED
MAR 1 2'2012
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING POOR OPENING DIMENSIONS.
171 •• 7,59
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
■
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (200 624 -2973
REGI }TEFED
ti HITE:CT
COTT 4TEMPE!
STATE OF r SHINGTON
0810.03.1839
2/24/11
0
0
ce
a
J
Z
Z
W
H
Z
Z
O
U
C�
Z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
z
0
I-
(9
Lctz_
C!)
co
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1839
(E) STUCCO TO REMAIN
SACKER ROD 4 SEALANT
Pte- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR WI
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
(E) EXTERIOR SHEATHING
2X2 BLOCKING, 4 SIDES
(P.T.)
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
WHERE WIDTH OF SOFFIT EXCEEDS
I6 ", INSTALL 2X4 STUDS e 16 OC.
5 /S" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
2x2 CONT. NAILER
12 "X16" ACCESS HATCH
FOR MAINTENANCE
BLENDING AIR UNIT ACCESS PANEL
1 1 /2" = 1' - 0"
EXISTING
CEILING
STRUCTURE
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE W/ ADJ.
ARCHITECTURAL FEATURES PER
PLAN. COORDINATE SOFFIT
DIMENSIONS WITH MECHANICAL
CONTRACTOR AND FIELD
CONDITIONS
EX
MAR .1 22012
ATTACH 2x3 LEDGER TO EXIST. DECK
ATTACH SOFFIT FRAMING TO LEDGER
SOFFIT DETAIL
11/2 " =1' -0"
COAT x I" WD BLOCKING WI
ADHESIVE MD INSERT AT (E) GWB
PANEL EDGE.
PROVIDE FINISH -GRADE PAINTABLE
GM EDGE AND CAULK JOINT
DUCTS PER PLAN WITHIN SOFFIT
WHERE WIDTH OF SOFFIT EXCEEDS 16 ",
PROVIDE 2x2 SOFFIT FRAMING • 16" O.C.
2x2 CONT. NAILER
54" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
MATCH EXIST. SOFFIT HT.
ED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
IPERMITCENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
0810.03.1839
2/24/11
0
cc
a
z w
O W
Ce
Z
CC Cr)
11-1 0
z Z
Z V
O
U Q
J
Z a
Y ~
Z
W
0
CO
W
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03A 839
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
WI
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEIUNG
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEIUNG DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL ABBR
XX
0
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON NE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -O" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL ABBR
$G X
XXX
+ f +
r%J
DN
UP
VD
RA /EA
RG
>CI
SA
SA
RA /EA
SD
EQUIP ID# �-
ICI
EA
MOD
NG NG
•
0
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WIN TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALOES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
140
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
2
SG -1
140
<.08" WG
8"
8"
WALL
DECO
1, 2, 3
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
WALL
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALOES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1839
597
2
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION I MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
EXPIRED
MAR 1 2 2012
1- 2__Vto
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51 -52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) 4a
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Prefe..lonal Limned 'MAW" Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(20e) 624 -8777 • FAX (206) 884-8 973
THE GREENBUSCH GROUP, INC
M••Sii. Se)
19(206) te 3-6n AD 9 VIDEO i 11192181001. ENGINEERING ST EET SD 901 SEATTLE. 90110
(20e) 37e -0041 FAX
0810.03.1839
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1839
KITCHEN
LIVING
ROOM
[I
BEDROOM
UNIT 13
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1P-0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
COORDINATE ACCESS
HATCH FOR ELECTRICA
AND MAINTENANCE
ACCESS WITH TECHNIC L
REPRESENTATIVE
C-2)
SOFFIT
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
2. HEATING IS PROVIDED BY ELECTRIC UNIT
HEATERS.
DUCT PER PLAN
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN SOFFIT.
COORDINATE MAINTENANCE HATCH WITH
TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DUCT PER PLAN
CAULK
FOAM BACKER ROD
WALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
EX 1 ED
MAR 1 2 2012
PI 1 2z(ia
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
NONE
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 08108
(206) 624 -2777 • FAX (206) 624 -2073
THE GREENBUSCH GROUP, INC
10011.180 11TrS,r Allma 1iI11E0 1 �1 gA11ll 9
(209) 378 -06811 (206) 379-0841 FAX
0810.03.1839
z
w
ft 0
O oC
Q
z w
0 w
rt
w
z
Z �
V
O
V <
J
Z Q
;-
z
w
w
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID GROUP M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, DO, MM &JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1839
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN
5:00 PM.
ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
PANEL
MP
LOCATION:
SERVING:
0810.03.1839
5111501.
10,000
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
RESIDENCE
ABC,
100
AMP with MAIN
BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
I INDICATES ISOLATED GROUND.
III I 1�
0
DAMPER CONNECTION
CKT
LOAD DESCRIPTION
TYPE
KVA
NP
PHASE
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
EXISTING LOAD
i
4012
A
B
30/2
®T
THERMOSTAT
EXISTING LOAD
2
4
5
EXISTING LOAD
20/1
A
30/2
EXISTING LOAD
6
r
7
9
11
SPACE
SPACE
BLENDING UNIT
PHASE LOAD PHASE A=
KVA
PHASE B=
15/1
15/1
2011**
#VALUE!
A
KVA.
B
B
20/1
EXISTING LOAD
8
10
12
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS
❑ RAINTIGHT NEM1\-3R ENCLOSURE ❑ DOUBLE LUGS
MAIN BKR SHUNTTRIP ❑ PANEL SKIRTS ❑ SURFACE
SERVICE ENTRANCE LABEL 0 INTEGRAL TVSS ❑ FLUSH
■
D
REMARKS:
** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM,
ELECTRICAL LEGEND
SY111301
DESCRIPTION
5111501.
DESCRIP'T'ION
G
LIGHTING OR POWER PANEL
m
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2"C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
I INDICATES ISOLATED GROUND.
III I 1�
0
DAMPER CONNECTION
❑'
NON -FUSED DISCONNECT SWITCH
o
MAST, WEATHERHEAD
❑S'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
0)
SMOKE DETECTOR
ELECTRICAL METER
i
TIMER OPERATED SWITCH
AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY.
®T
THERMOSTAT
— - —
11ECMANICAL I ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15
16
N/A
15
16
N/A
REMARKS
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
KITCHEN
1vING
ROOM
7
0810.13.1839 UNIT B
EXISTING ELECTRICAL PANEL
54TH
5EIDROCM
EKED ROOM
2
MP /11
MAIN FLOOR PLAN
114" = 1'
EXPIRED
MAR 1 2'2012
SEPARATp D
PERMIT
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
E NGINEERS, INO
N w NOON MO MIR NA• ON
7AMNA. WA MIME
MINIM OM IN MM
✓ x SIN 4111 ONO
0810.03.1839
H
ce
O
a
J
Z
0
H
Q
z
w
H
z
z
0
U
C7
Z
AIP NUMBER
MPROVEMENTS
5- 53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1839
-L1
5tHE ( mil ✓4..11 I
J
1 N
1
f
rat
I .._ VING
ROOM
&-E ROOK i
3
I
I'
L
,4TH
■
LAUNDRY"
KITCHEN
/ \
1 /
/ LI° `ING
/ / ROOM
/
1_��,
/ I
/ I
LL --
KITCHEN
IN
\
EXIST. ROOF LINE
\
L IV!NG\
ROOM \
1 I
L
UNIT 5
2
r
MAIN FLOOR AND ROOF PLAN
1/4" = 1'
NOTE:
I. LEAD PAINT IS PRESENT AT TI-115 RESIDENCE. REFER TO SECTION 01011
AND 02081.
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OWNERV FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO NE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE MD ROOMS IN THE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON NE SAME DAY BETWEEN 8 :00 AM AND 5:00 Ml.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
B. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS NTERVERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D MD RE- CONSTRUCT
SHELVING N COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SI4ELVNG SO AS NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
11. DIMENSIONS ARE FOR REFERENCE ONLY. HELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET 41.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST EE PROVIDED AT RESIDENCE BEFORE 8:00 All. 4 AFTER 5 :00 F.M.
l6. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
J
BEDROOM
CLOSET
5,4T1-1
18" x 24" EXIST.
ATTIC ACCESS
PANEL
CLOSET
(7/'
KITCI-4EN
DINING
ROOM
BEDROOM
2
CLOSET
L1
CLOSET
BEDROOM
3
LIVING
ROOM
U jr
IC - - --� r- --ter
—_J I I
I I I
L__1
J L
P
/
-
18" x 24" EXIST.
ATTIC ACCESS
PANEL
A
UPPER FLOOR PLAN
1/4" = 1'
/
/
/
/ \
/
/
/
-I
1
r—
NO INSULATION
REQUIRED -
\
\
I II �✓ V \
MAR 12'20121 1 I�/ = n _ N
1 L_ .\1
A. NORTH ELEVATION
B. EAST ELEVATION
PLAN KEYNOTES
00000000
DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2.0
DEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET 42.1
DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/422 FOR DETAIL. COORDINATE WITH
MECHANICAL.
BLENDING UNIT LOCATED ADJACENT TO (E) HATCH INSTALLED N ATTIC, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED CONTROL AND
DISCONNECT. REF. 2/422 FOR DETAIL.
COORDINATE CEILING GRILL WITH MECHANICAL.
INSTALL VENT BAFFLE(S) AT EXISTING RIDGE VENT(S) IN ATTIC, REF. 4/422 FOR DETAIL.
INSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/422 FOR DETAIL
INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
C. SOUTH ELEVATION
D. WEST ELEVATION
LEGEND
ACOUSTICAL WINDOW
NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.1
SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
EXISTING KITCHEN EXHAUST
/7E
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
VENT BAFFLE
NOT USED
NOT USED
NOT USED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVE
JUL 19 2011
p-. xoTCENTER
SD INSTALL BATTERY OPERATED SMOKE
DETECTORS
KITCHEN EXHAUST BAFFLE
GAS METER
_ 71110
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 824 -2973
REGISTERED
A;,HITECI
2/24/11
0810.03.1840
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
CX
NOTES
A1.0
0810.03.1840
WINDOW TYPES
SINGLE I4UNG
2
SLIDER/ FIXED/SLIDER
3
CASEMENT
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
LIVING ROOM
2
6' -0" x 4' -0"
STAIN/PAINT
-
1/42.0
B
LIVING ROOM
I
3' -2" x 3' -10"
STAIN/PAINT
1/A2.0
C
LIVING ROOM
I
3' -2" x 3' -I0"
STAIN/PAINT
1/42.0
D
DINING ROOM
I
3' -2" x 3' -10"
STAIN/PAINT
1/42.0
E
DINING ROOM
2
6' -6" x 2' -6"
STAIN/PAINT
1/42.0
F
KITCHEN
I
3' -6" x 4' -0"
STAIN/PAINT
1/42.0
G
BEDROOM 1
I
2' -4" x 5' -5"
STAIN/PAINT
1/42.0
H
BEDROOM 1
I
3' -4" x 5' -5"
STAIN/PAINT
1'
1/42.0
I
BEDROOM 2
I
3' -4" x 5' -5"
STAIN/PAINT
Y
I /42.0
J
BEDROOM 2
I
2' -4" x 3' -4"
STAIN/PAINT
1/42.0
K
BEDROOM 3
3
2' -4" x 4' -0"
STAIN/PAINT
Y
I/42.0
L
CORRIDOR (ABOVE STAIRS)
I
2' -8" x 3' -2"
STAIN/PAINT
1/42.0
(E) = EXISTING
(E) STUCCO
(E) STUCCO UNDERLAYMENT
SEALANT
COUNTERSINK SCREWS AND
FILL HOLES TYP.
(E) EXTERIOR SHEATHING
NEW STUCCO PATCH, MAINTAIN WIRE MESH
REINFORCEMENT.
STUCCO DRIP SCREED
PRE - PRIMED, GALV 51-IEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
MANUFACTURED Z -BAR FRAME
ACCOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) STUCCO TO REMAIN
STUCCO FIN BEHIND (E) LATH
114
WINDOW HEAD
(E) GWB
(E) WD. JAMB LINING. TO
REMAIN
WOOD TRIM, FINISH TO MAT
WOOD BLOCKING PER
Z -BAR FRAME
INSTALLATION
SEALANT
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
STUCCO FIN BEHIND (E) LATH
WINDOW NAIL FLANGE
(E) STUCCO TO REMAIN
(E) BUILDING PAPER
(E) EXTERIOR SHEATHING
WINDOW JAMB
IIII IIII 11 11
ICI
0
WINDOW SILL
(E) GWB
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
BACKER ROD I SEALANT
IX WOOD LEDGER
SEALANT BED
SEALANT 4 SACKER ROD
3/4" WD. SILL - STAIN
TO MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT/STAIN TO
MATCH (E) TRIM
1X WOOD LEDGER
SEALANT BED
(E) GWB
STUCCO - WINDOW DETAIL SET
3 " =1' -0"
TYPICAL WINDOW SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 05800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL SEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
1EXPI ED
MAR 1 2 2012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
•
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
COTT
STATE OF
2/24/11
0810.03.1840
TEMP
aHINGTON
0
a
z
0
z
w
z
0
v
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1840
DOOR TYPES
0
IA
FLUSH SCW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
EXTERIOR
SINGLE LEAF STORM
W/ SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
Wx H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
2'4" x 6' -6"
STAIN /STAN
HW -I / 619
DK -1
LOCK -I
1/A2.1
2
ENTRY
B
2' -S" x 6' -6"
1 /A2.1
INSTALL SPRING LOADED HINGES TO DOOR 1
(E) STUCCO TO REMAIN
BACKER ROD AND SEALANT
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MN.
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BAIT
INSULATION
WOOD FRAME
KEW AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTNUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
BACKER ROD AND SEALANT
(E) EXTERIOR PLYWOOD
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
JAMB BEYOND
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
2" MN.
DOOR JAMB
EXISTING FLOOR STRUCTURE
DOOR SILL
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SH111 AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
STUCCO - DOOR DETAIL SET
3 " =1' -0"
TYPICAL DOOR SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 05600 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
17Il -7,3(e
EXPIRED
MAR 1 2 2012
;
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
■
S . M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
REGISTERED
A.CHITECT
lollP!
COTT V T:EWE:
STATE OF. SHINGTUN
2/24/11
0810.03.1840
Et
O
a
Q J
Z
0
Q
z
ac
w
z
z
0
0
0
Z
AIP NUMBER
MPROVEMENTS
5- 53- 0058 -043
z
0
F-
00
Lil
z_
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1840
(E) STUCCO TO EMAIN
BACKER ROP 4 SEALANT
ME-PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR WI
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC At
EXTERIOR TRIM.
PRE - PRIMED, GALV SWEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
(E) EXTERIOR PLYWOOD
(E) EXTERIOR SHEATHING
2X2 BLOCKING, 4 SIDES
(P.T.)
AIR INTAKE DETAIL AT EXTERIOR
3 " =1' -0"
PREMANUFAGTIIRED ROOF
BAFFLE ! AN- MODEL
EXIST DUCTWORK
•Pk
EAL4,k NAILS WITH ROOF
CEMENT
SEAL SHINGLES TO ROOF
CAP ON TOP AND SIDES
NOTE:
I PREMANUFACTURED ROOF BAFFLE. INSTALL PER
MANUFACTURE'S INSTRUCTIONS.
KITCHEN EXHAUST BAFFLE
11/2 " =1' -0"
BLENDING AIR UNIT ACCESS PANEL
1 1/2 "= 1' -0"
SUSPEND MECI.4 UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
DISPLACE (E) INSULATION
TO FACILITATE INSTALLATION
OF MECHANICAL UNIT, DUCTS
AND ACCESS HATCH
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
INSULATION STOP AT
PERIMETER OF ACCESS
HATCH OPENING, 4 SIDES -
2x WD BLOCKING
EXISTING VENT COVER
EXISTING ROOF
STRICTURE
EXISTING ROOF VENT
EXISTING ROOF
STRUCTURE
CROSS SECTION
NEW 2"X SPACER AS
REQUIRED TO PROVIDE
6" CLEAR AIR SPACE
NEW 2 "X SPACER
ANCHOR CEILING NAILER
TO (E) RESILIENT
CHANNEL ONLY. DO NOT
ANCHOR TO JOIST
WHERE WIDTH OF SOFFIT
EXCEEDS 16 ", INSTALL 2X4
STUDS * 16" O.C.
J -METAL EDGE AND
CAULK JOINT
(E) ATTIC
LATERAL SECTION
RIDGE VENT BAFFLE
11/2 " =1' -0"
DUCT
CHASE
4064
/1 /!
Fr
411114111111 14
r
c
SOFFIT DETAIL
EX
MAR 1 2'2012
6" MIN. TYPICAL TOP 4
BOTTOM
NEW P' INSULATION BOARD
GLUED TO NEW 3/4"
EXTERIOR GRADE
PLYWOOD.
DEMOLISH (E) GWB
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
NOTCH TOP PLATE AND TRIM STUDS
OF PARTITION AS REQ'D TO ACCOMMODATE
PASSAGE OF MECH. COMPONENTS. WALL
PENETRATIONS SHALL BE CUT FULL SIZE
OF SOFFIT AREA, TYPICAL
2x BLOCKING BETWEEN STUDS
WHICH REQUIRE TRIMMING
2x2 CONT. NAILER
5 /S" GWB- FAINT TO MATCH (E) TEXTURE 4
COLOR OF CEILING.
ENCLOSE DUCTS TIGHTLY, OR TERMINATE
EDGE LW ADJ. ARCHITECTURAL FEATURES
PER PLAN. COORDINATE SOFFIT DIMENSIONS
WITH MECHANICAL
(E) WD FRAME WALL ASSEMBLY
11/2 " =1' -0"
RECEIVEr
JUL 19 2011
PERMIT CENTEF
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
COTT 4 T.EMPE
STATE OF l HINGT)N
2/24/11
0810.03.1840
O
0
J
Q
z
0
z
w
H
z
0
U
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
MISC.
DETAILS
A2.2
0810.03.1840
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTU H
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEIUNG
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEIUNG DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANI ZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STA11C PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STA11C PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
IMTH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
AC)
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEIUNGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
8. THERMOSTATS 4' -0" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
10.
11.
12.
SYMBOL
SG -X
XXX
ABBR
UP I +
f f
Swm-
N
-11) I- 4R-I-
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
4.VD
RA /EA
OR
EQUIP ID
NG
•
3
0
DUCT FLEX
CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RG RETURN AIR GRILLE
SA SUPPLY AIR OUTLET, SIDEWALL
SA SUPPLY AIR DUCT
RA /EA RETURN AIR OR EXHAUST AIR DUCT
SD SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE /DUCT ELBOW DOWN
PIPE /DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WI11-I BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
165
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STA11C
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
3
SG -1
165
<.08" WG
8"
8"
CEILING
DECO
1, 2, 3
OG -1
90
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WI11-I BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1840
1148
3
90 CFM
90 CFM
1,3
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION I
MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
EXPI E
MAR 1 22012
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) II
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION ]
QF = 45 / (1 X 1/2) = 90 CFM
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE T AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2Y73
THE GREENBUSCH GROUP, INC
011•00
)))
A001)SflCM., AUpO VIDEO t ME WIa*L Eg0IE�IG
1900 9F91 sir SUITE 701 9FA1Rz M Mill
(206) 376 -069 (206) 378 -0041 FAX
0810.03.1840
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1840
BEDROOM
SEE
BATH
BEDROOM
2
BEDROOM
B.C2=1 3
25
IDINING
ROOM
TYP ALL
CEILING GRILLES
LIVING
ROOM
UPPER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1' -0"
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
USE EXISTING ATTIC
ACCESS HATCH FOR
ELECTRICAL AND
MAINTENANCE
ACCESS
ATTIC
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
UNIT C
NORTH
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
FLAG NOTES:
13V -1 AND DUCTWORK ROUTED IN ATTIC. USE
EXISTING ATTIC ACCESS HATCH FOR
MAINTENANCE AND ELECTRICAL ACCESS.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
DUCT PER PLAN
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
NONE
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
DUCT PER PLAN
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER
2. SEE PLANS FOR VOLUME DAMPER LOC
3. CEILING SUPPLY INSTALLATION SHOWN,
COORDINATE SOFFIT WITH
TECHNICAL REPRESENTATIVE
FIELD FABRICATE PLENUM
BEHIND CEILING GRILLE
CAULK
FOAM BACKER ROD
ARCHITECT TO PROVIDE 2X4
BLOCKING TO SUPPORT CEILING
CUTTING
FLOOR OR CEILING JOIST
CEILING
SLEEVE AND ESCUTCHEON
GRILLE
MANUFACTURER'S WRITTEN INSTRUCTIONS.
ATI ONS.
RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
NONE
EXPIRED
MAR 1 2 2012
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Pro2ei tonal Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, 1►A 98106
(2011) 624-2777 • FAX (206) 624 -8973
THE GREENBUSCH GROUP, INC
0...
)))
uoR
.ENO lee) & IE IWI L OL IO
slil6Er m1 S .►.eii.
(206) 376 -0589 SPASM 378-01141 FAX
0810.03.1840
KING COUNTY INTERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
MAIN FLOOR
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.1840
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN
5:00 PM.
ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH
INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
0 PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
0 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
O4 DEMO EXISTING SMOKE DETECTORS. PROVIDE PATCH WORK TO MATCH EXISTING CONDITIONS. PROVIDE INTERCONNECTED 120V SMOKE
DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE
ATTIC.
PANEL
MP
LOCATION:
SERVING:
0810.03.1840
SYMBOL
100,000
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
RESIDENCE
AIC,
100
AMP with MAIN
AND EQUIP R INDICATED ON PLANS. CONDUIT (WIRING AND! CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
Ink 1k
0
CKT
LOAD DESCRIPTION
TYPE
KVA
A/P
PHASE
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
EXISTING LOAD
ELECTRICAL METER
®
40/2
A
B
30/2
TIMER OPERATED SWITCH
EXISTING LOAD
2
4
5
7
9
11
EXISTING LOAD
EXISTING LOAD
EXISTING LOAD
SPACE
PHASE LOAD PHASE kz
#VALUE!
KVA
PHASE B-
20/1
20/1
20/1
#VALUE!
A
A
KVA.
B
B
20/2
2011**
2011 **
EXISTING LOAD
BENDING UNIT
SMOKE DETECTORS
6
8
10
12
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
ISOLATED GROUND BUS
RAINTIGHT NEMA -3R ENCLOSURE
❑
FEED THRU LUGS
DOUBLE LUGS
❑
MAIN BKR SHUNTTRIP
SERVICE ENTRANCE LABEL
PANEL SKIRTS ❑ SURFACE
INTEGRAL TV SS ❑ FLUSH
III
■
❑
■
■
11
REMARKS:
** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM.
15/1
t'1 BLACK
L —O O
N
WHITE
ELECTRICAL LEGEND
SYMBOL
DESCRIPTION
SYMBOL
DESCRIPTION
G
LIGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
AND EQUIP R INDICATED ON PLANS. CONDUIT (WIRING AND! CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
i INDICATES ISOLATED GROUND.
Ink 1k
0
DAMPER CONNECTION
D'
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
OS'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
BRANCH CIRCUIT HOME RUN
1 D
FIRE ALARM SMOKE DETECTOR 120V OPERATED
�-
I-131
ELECTRICAL METER
®
FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U111JTY.
TIMER OPERATED SWITCH
— - —
T®
THERMOSTAT
tA\--9.ze
BLACK
WHITE
RED
BK
BLACK
WHITE
SMOKE DETECTOR WIRING DIAGRAM
NO SCALE
RED
MECHANICAL ! ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
15
16
15
16
N/A
15
16
N/A
REMARKS
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
1,2
SWITCHES (ON, 11MER)
120
X
X
X
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL AL)
2 - DISCONNECT SWITCH
0810.13.1840 UNIT C
ELECTRICAL PANEL IS LOCATED
IN HALLWAY ON MAIN LEVEL NEAR THE
STAIRWELL
®INING
R®01'1
EXPI "ED
UNIT C
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
MAR 1 2 2012
RECEIVED
JUL 19 2011
PERMITCENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
1111011111111113. 1110
U M WM ISO .nor. SIMI wI
=Men UM A.R.
II..I IA MOUS
0810.03.1840
F-
0
a
J
Z
0
z
w
H
z
z
0
0
0
Z
AIP NUMBER
MPROVEMENTS
5 -53- 0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1840
NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT TH15 RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED
TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL 8E
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR
REGULATED MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011
AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
7
E Imo+ C,7i1
2
R ..00M
um-r
MAIN FLOOR PLAN
1/4" = 1'
NOTE:
INTERIOR TRIM TO BE FINISHED TO MATCH EXISTING
GENERAL NOTES
1. CONTRACTOR TO PROTECT OII,NERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST.
2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE
DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY.
3, ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS.
5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO S:00 AM EACH DAY.
HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN NE RESIDENCE FOR WEEKENDS.
6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 All AND 5:00 PM.
1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
S. ALL WORK AREAS SHALL BE BROOM - CLEANED AT THE END OF EACH WORK DAY.
9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT
SHELVING IN COORDINATION WIN SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING SO AS NOT TO INTERFERE WIN THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES.
II. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE SEVERAL
GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE PROJECT
LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT.
13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET A1.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL
SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS.
14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE.
15. MAXIMUM POWER OUTAGE IS EIGHT HOURS. POWER MUST BE PROVIDED AT RESIDENCE BEFORE 8:00 AM. 4 AFTER 5:00 P.M.
16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL
FOR TIMER LOCATION
11. CONTRACTOR IS TO VERIFY NAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL.
IS. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT,
TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION IS UNCOVERED.
13 EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT
AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED.
r
KI
1..IViN
ROOM
rr
BEDROOM
3
l
._._..�-- ..- .-- ..._r_._.?
I I
I !
I ! I
1 i I
5ELD ROOM
MAR 1 2 2012
,ATM
PLAN KEYNOTES
I DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET A2,0
ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR, FRAME, CASING, AND STORM DOOR REF.
DOOR SCHEDULE ON SHEET All
ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I/A22 FOR DETAIL. COORDINATE WITH
MECHANICAL.
4 O BLENDING UNIT LOCATED IN NEW SOFFIT, NEW ACCESS HATCH INSTALLED IN SOFFIT, REF. MECH. FOR UNIT, REF. ELECT. FOR SPEED
CONTROL AND DISCONNECT. REF. 2/422 FOR DETAIL.
OCOORDINATE WALL GRILL WITH MECHANICAL. WALL PENETRATION SHALL BE CUT FULL SIZE OF DUCT AREA. REF. MECH. FOR INSTALLATION
DETAIL.
® INSTALL PROGRAMMABLE TIMER SWITCH FOR CONTROL OF BLENDING AIR UNIT. COORDINATE. MECHANICAL AND ELECTRICAL.
c
wl ��
40.5.0° 20„,...
S t
ACCESS TO SITE AND PARKING
1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY.
E3EIDROOM
2
L IN1T
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
A. NORTH ELEVATION
B. EAST ELEVATION
C. EAST ELEVATION
D. SOUTH ELEVATION
E. WEST ELEVATION
LEGEND
T
T
ACOUSTICAL WINDOW
NOT USED
EXTERIOR STORM DOOR:
DIMENSIONS WILL VARY.
SEE DOOR SCHEDULE ON ARCH. A2.1
SEE WINDOW SCHEDULE FOR
WINDOW TYPES
FLOOR / CEILING GRILL
NOT USED
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE. REF. MECH.
FOR UNIT.
NOT USED
11111 WALL GRILL
!GAS
NOT USED
NOT USED
ECEIVED
JUL 19 2011
P _,-..Y,.TCENTER
INSTALL BATTERY OPERATED SMOKE
DETECTORS
NOT USED
GAS METER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 824 -2973
REGISTERED
A HITECT
0810.03.1841
TEMP
u SHINGTON •
2/24/11
0
a.
J
z
0
1
z
w
z
z
O
0
00
z
MPROVEMENTS
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
FLOOR
PLANS
NOTES
A1.0
0810.03.1841
WINDOW TYPES
2'L 0" 1'11N.
SINGLE HUNG
2
SLIDER/ FIXED/SLIDER
WINDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
EGRESS
DETAIL
SET
A
LIVING ROOM
2
5' -4" x 4' -4"
STAIN/PAINT
SAFETY GLAZING REQUIRED
I/A2.0
B
KITCHEN
I
2' -0" x 2' -10"
STAIN/PAINT
I /A2.0
C
BEDROOM 1
1
2' -10" x 3' -10"
STAIN/PAINT
I /42.0
D
BEDROOM I
2
5' -10" x 1' -10"
STAIN/PAINT
CUT SILL TO 40" AFF FOR EGRESS (E) HT. 5T'
Y
1/42.0
E
BEDROOM 2
2
51-1011x I' -I0"
STAIN/PAINT
CUT SILL TO 40" AFF FOR EGRESS (E) Ht. 5i"
y
1/42.0
F
BEDROOM 3
I
2' -10" x 2' -I0"
STAIN/PAINT
1/A2.0
G
BEDROOM 3
2
5' -S" x 2' -0"
STAIN/PAINT
SAFETY GLAZING REQUIRED
Y
1442.0
(E) 2 EXISTING
(E) STUCCO
(E) STUCCO UNDERLAYMENT
SEALANT
COUNTERSINK SCREWS AND
FILL 1-IDLES TYP.
(E) EXTERIOR SHEATHING
NEW STUCCO PATCH, MAINTAIN WIRE MESH
REINFORCEMENT.
STUCCO DRIP SCREED
PRE - PRIMED, GALV SHEET METAL
FLASHING UNDER SELF- ADHERING
MEMBRANE. COLOR TO BE SELECTED
IN THE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
MANUFACTURED Z -BAR FRAME
ACCOUSTICAL WINDOW ASSEMBLY
(E) EXTERIOR SHEATHING
(E) BUILDING PAPER
(E) STUCCO TO REMAIN
1
Imo
�I
x
hud
WINDOW HEAD
(E) GWB
(E) WD. JAMB LINING. TO
REMAIN
WOOD TRIM, FINISH TO MATCH (E)
WOOD BLOCKING PER
Z -BAR FRAME
INSTALLATION
SEALANT
STUCCO FIN BEHIND (E) LATH
BACKER ROD I SEALANT
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD 4 SEALANT
STUCCO FIN BEHIND (E) LATH
WINDOW NAIL FLANGE
(E) STUCCO TO REMAIN
(E) BUILDING PAPER
(E) EXTERIOR SHEATHING
WINDOW JAMB
0
WINDOW SILL
(E) GWB
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH
(E) TRIM
BACKER ROD 4 SEALANT
1X WOOD LEDGER
SEALANT BED
SEALANT I BACKER ROD
3/4" WD. SILL - STAIN
TO MATCH (E)
WOOD TRIM TO MATCH
(E), PAINT /STAIN TO
MATCH (E) TRIM
lx WOOD LEDGER
SEALANT BED
(E) GWB
STUCCO - WINDOW DETAIL SET
3" = 1' - 0"
TYPICAL WINDOW SCHEDULE NOTES
I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 0S800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
MAR 1 21012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 032011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMIT CENTER
•
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • PAK (206) 624 -2973
COTT
,STATE OF
0810.03.1841
2/24/I1
F-
O
J
z
O
Q
z
w
F
z
z
0
0
0
AIP NUMBER
MPROVEMENTS
w
2
w
w
0
z
LL
U
OC
a
5- 53- 0058 -043
DATE
ISSUED
2/24/11
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.1841
DOOR TYPES
0
A
FLUSH 5CW
W/ WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
W/ OBSERVATION PORT
EXTERIOR
SINGLE LEAF STORM
WI SAFETY GLAZING
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
Wx H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
I
ENTRY
A
3' -0" x 6' -8"
STAIN /STAIN
14W -I / 626
DK -2
LOCK -I
1 /A2.1
2
ENTRY
B
3' -0" x 6' -8"
I /A2.1
(E) STUCCO TO REMAIN
BACKER ROD AND SEALANT
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE SELECTED
N THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STORM DOOR PER SCHEDULE
2" MIN.
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
WOOD TRIM TO MATCH (E),
PAINT/STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
WOOD FRAME
KERF AS REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
DOOR HEAD
BACKER ROD AND SEALANT
CONTINUOUS SEALANT BEHIND
Z BAR FRAME
STOW' DOOR PER SCHEDULE
KERF AS REQUIRED FOR WEATHER
STRIPPING INSTALLATION
CONTINUOUS WEATHER- STRIPPING
JAMB BEYOND
DOOR JAMB
WOOD DOOR PER SCHEDULE
DOOR SHOE
2" MN.
AUTOMATIC DOOR SWEEP
ALUMINUM THRESHOLD
ADJUSTABLE SWEEP
EXISTING FLOOR STRUCTURE
se
DOOR SILL
(E) EXTERIOR PLYWOOD
EXISTING FRAMING
WOOD TRIM TO MATCH (E),
PAINT /STAIN TO MATCH (E)
TRIM
SHIM AS NECESSARY
FILL GAP W/ BATT
INSULATION
DOOR PER SCHEDULE
STUCCO - DOOR DETAIL SET
3 " =1' -0"
174\
TYPICAL DOOR SCHEDULE NOTES
L NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED
IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COYER
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
EXPIRED
MAR 1 22012
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
RECEIVED
JUL 19 2011
PERMITCENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (208) 624 -2973
REGISTERED
Ac ,HITE:CT
2/24/11
0810.03.1841
H
ce
O
a
J
Z
0
z
w
z
z
0
U
0
Z
MPROVEMENTS
D
ce
W
W
W
0
Zce
ce
H
AIP NUMBER
5- 53- 0058 -043
z
O
0
z_
DATE
2/24111
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA,LB &JH
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
0810.03.1841
MAR 1
2012
(E) STUCCO TO REMAIN
SACKER ROD 4 SEALANT
(E) WALL UNDERLAYMENT
SELF ADHERING BITUMINOUS
MEMBRANE FLASHING
PRE- PRIMED, GALV SWEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
EXTERIOR VENTILATION FIXTURE.
REF. MECH.- PAINT INTERIOR W/
ACOUSTICAL DAMPING
COMPOUND. SET IN MASTIC AT
EXTERIOR TRIM.
PRE- PRIMED, GALV SHEET METAL
FLASHING UNDER SELF - ADHERING
MEMBRANE. COLOR TO BE
SELECTED IN THE FIELD
BACKER ROD 4 SEALANT
(E) STUCCO TO REMAIN
(E) EXTERIOR PLYWOOD
(E) EXTERIOR SHEATHING
2X2 BLOCKING, 4 SIDES
(P.T.)
AIR INTAKE DETAIL AT EXTERIOR
3" = 1' - 0"
SUSPEND MECH UNITS FROM
(E) STRUCTURE RE:
MECHANICAL
MECH UNIT AND DUCTS -
REF MECHANICAL
CONTINUOUS VIBRATION
DAMPENING PAD RE:
MECHANICAL
EXISTING
CEILING
STRUCTURE
ENCLOSE DUCTS TIGHTLY, OR
TERMINATE EDGE W/ ADJ.
ARCHITECTURAL FEATURES PER
PLAN. COORDINATE SOFFIT
DIMENSIONS WITH MECHANICAL
CONTRACTOR AND FIELD
CONDITIONS
WHERE WIDTH OF SOFFIT EXCEEDS
16 ", INSTALL 2X4 STUDS a 16" O .C.
5/5" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
2x2 CONT. NAILER
12 "XI6" ACCESS HATCH
FOR MAINTENANCE
BLENDING AIR UNIT ACCESS PANEL
11/2 " =1' -0"
SOFFIT DETAIL
REVIEWED FOR
CODE COMPLIANCE
APPROVED
AUG 0 3 2011
City of Tukwila
BUILDING DIVISION
ATTACH 2x3 LEDGER TO EXIST. PECK
ATTACH SOFFIT FRAMING TO LEDGER
COAT 1 " x 1" WD BLOCKING WI
ADHESIVE AND INSERT AT (E) GWB
PANEL EDGE.
PROVIDE FINISH -GRADE PAINTABLE
GWB EDGE AND CAULK JOINT
DUCTS PER PLAN WITHIN SOFFIT
WHERE WIDTH OF SOFFIT EXCEEDS 16 ",
PROVIDE 2x2 SOFFIT FRAMING ® 16" O.C.
2x2 CONT. NAILER
%" GWB- PAINT TO MATCH (E)
TEXTURE 4 COLOR OF CEILING.
1 1/2" = 1' - 0"
MATCH EXIST. SOFFIT HT.
RECEIVED
JUL 19 2011
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
REGISTERED
A,H[TE_CT
0810.03.1841
2/24/11
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
DATE
2/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML &TF
DRAWN
AA, LB &JH
MISC.
DETAILS
A2.2
0810.03.1841
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASH RAE
BFC
BFF
BOD
BTU H
CD
CFM
CI RC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
Ao
XX
OR XX
0
X/Y
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
5. AIRTIGHT.
PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 10' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
6.
7.
8.
10.
11.
12.
SYMBOL
SG
ABBR
f +
S'Em-mA.0
.4+ x
+ f +
-el- el--
(ZOR
EQUIP ID# .
NG
•
O
0
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
VD
RA /EA
RG
SA
SA
RA /EA
SD
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL / ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
4"
4"
X
DECO
1, 2, 3
X
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
1,2
-
SWITCHES (ON, TIMER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
165
.5" WG
32 "Lx12.25 "Wx8.5 "H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
3
SG -1
165
<.08" WG
8"
8"
WALL
DECO
1, 2, 3
OG -1
90
<.08" WG
7»
7"
WALL
WALL CAP
1, 2, 3, 4
RG -1
25
<.08" WG
4"
4"
WALL
DECO
1, 2, 3
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
3. PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
4. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
WAC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.1841
875
3
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION I MIN VALUE (NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R -8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING
R -8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R -8
1,3
IN CEMENT SLAB OR IN GROUND
R -5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 01011 AND 02080 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO
EXTERIOR WINDOW TRIM PAINT.
EXpi
MAR 1 2 2012
ED
THERMOSTAT /SWITCH HOURS OF OPERATION
SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
MECHANICAL VENTILATION CALCULATION
PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES)
QF = QR / ( &EGR X F)
QR = (FROM TABLE 403.8.1) 5
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/1.
QF = 45 / (1 X 1/2) = 90 CFM
RECEIVED
JUL 19 2011
PERMIT CENTER
SEPARATE
PERM AND
APPROVAL
REQUIRED
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited liability company
4000 DELRIDGE WAY SW
SU1T11 200 • SEATIL6, WA 98106
(20e) 624 -8777 • FAX (206) 1124 -2973
THE GREENBUSCH GROUP, INC
.....ai...)
ADOIISIN'N, N1d0_/ VDED 3 YECIMNGIL ENOtEE116
1006 !ESL. sir BUBE 901 9FARE, 00110
(206) 378 -0309 (206) 378 -0641 FAX
0810.03.1841
KING COUNTY INTERNATIONAL AIRPORT
U)
0
0
2
0
w
w
ce
w
O
z
Q
w
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED
BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M1.0
0810.03.1841
SOFFIT BY
OTHERS
7"o
410
/BEDROOM
EU-
25
UNIT D
SOFFIT BY
OTHERS
Ba II
25
BEDROOM 6"�
2
Agh
M2.0
8"d
BATH
SEE
KITCI4EN
LAUNDRY
MAIN FLOOR MECHANICAL PLAN
INSTALL PER THE
MANUFACTURER'S
WRITTEN INSTRUCTIONS
OUTSIDE AIR
DUCT
16" MIN
RETURN AIR
DUCT
FILTERS ACCESS
MOTOR ACCESS
HOLD TIGHT TO
STRUCTURE
COORDINATE ACCESS
HATCH FOR ELECTRIC
AND MAINTENANCE
ACCESS WITH TECHNIC L
REPRESENTATIVE
SOFFIT
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSULATE ALL DUCT AS SCHEDULED.
BLENDING UNIT INSTALLATION DETAIL
NONE
4"0
4,
1 65 SEE uo n TYP ALL
WALL GRILLES
NORTH
B25 ]
LIVING
ROOM
B DROOM
3
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
CAULK
FOAM BACKER ROD
WALL CAP OR SIDEWALL GRILLE
DUCT PER PLAN
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS,
REFERENCE 1/A2.2 FOR DETAIL.
WALL CAP INSTALLATION DETAIL
3 NONE
SHEETMETAL
TRANSITION
TO GRILLE
NECK SIZE
DRAWING NOTES:
FIELD VERIFY OUTSIDE AIR INLET LOCATION IS
AT MINIMUM 10 FEET AWAY OR 2 FEET
BELOW ANY HAZARDOUS OR NOXIOUS
SOURCE PER SMC 401.5.1.
FLAG NOTES:
BV -1 AND DUCTWORK ROUTED IN SOFFIT.
COORDINATE MAINTENANCE HATCH WITH
TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE
TIMER SWITCH BY TECHNICAL SPECIFICATIONS
SECTION 16100. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51 -52- 0403.8.2 -5.8.
TRANSITION DUCT TO AIR TERMINAL NECK
SIZE IMMEDIATELY BEFORE MAKING FINAL
GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS
REQUIRED TO INSTALL OUTSIDE AIR INLET,
REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCTS AS SCHEDULED. REFER
TO THE MINIMUM DUCT INSULATION
THICKNESS SCHEDULE ON M1.0.
DUCT PER PLAN
EX
RED
MAR 1 2 2012
1c)\\Mg
CAULK
FOAM BACKER ROD
WALL GRILLE
SLEEVE AND ESCUTCHEON
WALL
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
CEILING GRILLE INSTALLATION DETAIL
NONE
SEPARATE
p�
PERMIT
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMITCENTER
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
• Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 SEATTLE, WA 98106
(806) 624-2777 • FAX (206) E24 -8979
THE GREENBUSCH GROUP, INC
••••011111101111)))
AMID NRE) 8 IEDWICIIL OIA111519
1909 11881 SIIiEr 9UIE ffi1 gRl11Fi. it 11!1114
(206) 378 -0569 (209) 378-0941 FAX
0810.03.1841
KING COUNTY INTERNATIONAL AIRPORT
AIP NUMBER
5 -53 -0058 -043
SEATTLE WASHINGTON
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CA
PROJECT MANAGER
CA
DRAWN
CA, JA
MAIN FLOOR
MECHANICAL
PLAN AND
DETAILS
M2.0
0810.03.1841
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE UMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8: 00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
C : PROVIDE COMPLETE POWER AND CONTROL CONNECTION FOR BLENDING UNIT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
O PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS TO BLENDING UNIT. SEE SPECIFICATIONS FOR TYPE.
03 HOME RUN CIRCUIT TO PANEL -MP AND MAKE ALL CONNECTIONS COMPLETE. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY
CEILING OR WALL PENETRATION WORK.
PANEL
MP
LOCATION:
SERVING:
0810.03.1841
SYMBOL
10,000
120/240
VOLT,
1 PHASE, 3
WIRE.
BKR
G
RESIDENCE
AIC,
100
AMP with MAIN
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
1 1 1 1 1 1
4
CKT
LOAD DESCRIPTION
TYPE
KVA
A/P
I=
NP
KVA
TYPE
LOAD DESCRIPTION
CKT
1
3
EXISTING LOAD
ELECTRICAL METER
40/2
A
30/2
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY.
TO
EXISTING LOAD
2
4
5
EXISTING LOAD
X
30/2
A
■
20/1
1
EXISTING LOAD
6
7
9
11
SPACE
PHASE LOAD PHASE A=
KVA,
PHASE B=
20/2
#VALUE+,
A
KVA.
B
B
15/1
15/1
2011'
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
EXISTING LOAD
BLENDING UNIT
8
10
12
LOAD TYPE
L
R
M
H
WH
D
A
K
LM
TOTAL LOADS
CONN. LOAD
KVA
AMP
COMPUTED LOAD
KVA
AMP
❑ ISOLATED GROUND BUS
❑ RAINTIGHT NEMA -3R ENCLOSURE
FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ PANEL SKIRTS ❑ SURFACE
DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL ❑ INTEGRAL TVSS ❑ FLUSH
■
❑
REMARKS:
** PROVIDE NEW BREAKER TO MATCH EXISTING SYSTEM.
ELECTRICAL LEGENID
SYMBOL
PESCRIPtION
SYMBOL
DESCRIPTION
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
G
LIGHTING OR POWER PANEL
PH
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPECIFIC REQUIREMENTS.
BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES
AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE.
#12 AWG, 1/2 "C. MIN. EMT OR RIGID STEEL. 1 INDICATES EQUIP GND.
1 INDICATES ISOLATED GROUND.
15
1 1 1 1 1 1
4
DAMPER CONNECTION
D'
NON -FUSED DISCONNECT SWITCH
0
MAST, WEATHERHEAD
0'
TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
120
BRANCH CIRCUIT HOME RUN RUN
frg1
SMOKE DETECTOR
EJ
ELECTRICAL METER
i
11MER OPERATED SWITCH
1,2
AERIAL SERVICE CONDUCTORS, COORDINATE WITH U11UTY.
TO
THERMOSTAT
- - -
X
X
MECLANICAL / ELECTRICAL COOS «NATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
DESCRIPTION
VOLTS
PH
15
16
15
16
N/A
15
16
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
X
X
1,2
-
SWITCHES (ON, 11MER)
120
1
X
X
X
1
REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
MAR 1 2 2012
vi01 -2-�
UNITD
SE D IROOM
1
KITCHEN
LAUNDRY
5EDROOM
3
LIVING
ROOM
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
RECEIVED
JUL 19 2011
PERMIT CENTER
S.M.STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624 -2777 • FAX (206) 624 -2973
EN•INE!NI, INO
IMO Baru 41111. 111111M wn..N
MOM WA 11141111411111111
M..ua. NOM ORS
IVIK Mew NS Mr
0810.03.1841
F-
0
0
J
z
0
F-
Q
LL
w
I-
z
z
O
U
0
z
MPROVEMENTS
AIP NUMBER
5 -53- 0058 -043
z
0
F-
0
z
F-
t-
DATE
02/24/11
ISSUED BID PACKAGE M -24
100% CD
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
JAB
FLOOR
PLANS
NOTES
E1.0
0810.03.1841