HomeMy WebLinkAboutPermit D11-281 - FOSTER PRESBYTERIAN CHURCH - EXTERIOR IMPROVEMENTFOSTER PRESBYTERIAN CHURCH 1440156 AV S Dl 1 -281 City 4/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206. 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 3365900060 Address: 14401 56 AV S TUKW Suite No: Project Name: FOSTER PRESBYTERIAN CHURCH Permit Number: D11 -281 Issue Date: 08/19/2011 Permit Expires On: 02/15/2012 Owner: Name: FOSTER PRESBYTERIAN CHURCH Address: P 0 BOX 88576 , TUKWILA WA 98188 Contact Person: Name: FRED MEYER Address: 16468 MARINE VIEW DR SW , BURIEN WA 98166 Contractor: Name: FRED MEYER ROOFING Address: 16468 MARINE VIEW DR SW , BURIEN WA 98166 Contractor License No: t 1,k MIL M9 Phone: 206 478 -3733 Phone: 206 - 478 -3733 Expiration Date: 02474013 0112.417,4V7 DESCRIPTION OF WORK: 1) REMOVE EXISTING ASPHALT SHINGLES 2) INSTALL 1/2" PLYWOOD OVER EXISTING TONGUE AND GROOVE SHIP LATHE. 3) INSTALL LANDMARK LIMITED LIFETIME ARCHITECTURAL SHINGLES. 4) INSTALL NEW CONTINUOUS GUTTERS AND DOWNSPOUTS. Value of Construction: $28,000.00 Fees Collected: $1,672.28 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0005 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11-281 Printed: 08 -19 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N N N • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: The granting of construction or t to this permit. Signature: h Date: rmit does not ance of wo Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development permit and agree to the conditions attached Print Name: Q S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -281 Printed: 08 -19 -2011 litf tot CITY OF TUKA Community DevelMnent Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.ctov Building Pe. No. Mechanical Permit No. till— 2�1 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: /99'©/ 4-6 -ft., Aire King Co Assessor's Tax No.: � '.4/A-1() j L Suite Number: Tenant Name: ��kPi TVk_lv\LL fad h. %2(;a. i'AtNo4 - Property Owners Name: 4—‘39-6 r v44 \l i G Mailing Address: GOUNAQ.) Floor: New Tenant: ❑ Yes ❑.. No City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Mailing Address: ( ( d ' 7 t4a ; h L Vi 01 O. S 1'✓ j✓ r; Day Telephone: ?� h- 3733 ortor clw /t'oep Zip (�11� ((�� City E -Mail Address: rt'-1'Y1 /2-4-1er i' 0 0 4i Tv htiSYl C Om Fax Number: State GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: tMQ Q l ROCg Mailing Address: L (o %144.1r1, , Q V ;Q. W DT- S v✓ Contact Person: E -Mail Address: AA °"4-e.r Contractor Registration Number: o -h `fir Q c—oy, Nuw2- i9119 1 City State Zip k, 'riff 3733 Day Telephone: Fax Number: Expiration Date: (3112°1 i5 ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:1Applications\Por s- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: May 2011 bh Page 1 of 6 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid pr : $ 2)G OUO Existing wilding Valuation: $ Scope of Work (please provide detailed informa tion): :.Q Mnpvo QK? <-4-` ' ti A 1t v P (riwoz)cn ti t'g O,Ce.r C3\1 ® (os.,- , t �s � a CAC) Will there be new rack storage? ❑ ....Yes If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: May 2011 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line12010 Applications17 -2010 - Permit Application.doc Revised: May 2011 bh Page 2 of 6 PERMIT APPLICATION NOTES — 41icable to all permits in this application • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: UTHORIZED AGENT: Print Name: Mailing Address: Ko k(a )1/4,6x,-,,,. V a e is -Qr. SAI Date Application Accepted: mitisit■ Date: Day Telephone: `LG,to Pric6 (b1-33 \Jt .71-.t.kCo City Date Application Expires: 02_1 I' 1_ H:\Applications\Forns- Applications On Line\2010 Applications \7 -2010 - Permit Application doc Revised: May 2011 bh State Zip Staff Initials: 6 w Page 6 of 6 1 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3365900060 Permit Number: D11-281 Address: 14401 56 AV S TUKW Status: APPROVED Suite No: Applied Date: 08/15/2011 Applicant: FOSTER PRESBYTERIAN CHURCH Issue Date: Receipt No.: R11 -01811 Initials: User ID: JEM 1165 Payment Amount: $629.35 Payment Date: 08/19/2011 12:40 PM Balance: $0.00 Payee: FRED W MEYER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04508B ACCOUNT ITEM LIST: Description 629.35 Account Code Current Pmts BUILDING - NONRES 000.322.100 629.35 Total: $629.35 doc: Receiot -06 Printed: 08 -19 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 3365900060 Permit Number: D11-281 Address: 14401 56 AV S TUKW Status: PENDING Suite No: Applied Date: 08/15/2011 Applicant: FOSTER PRESBYTERIAN CHURCH Issue Date: Receipt No.: R11 -01767 Initials: User ID: JEM 1165 Payment Amount: $1,042.93 Payment Date: 08/15/2011 01:08 PM Balance: $0.00 Payee: FRED W MEYER, FMR TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 04161Z ACCOUNT ITEM LIST: Description 1,042.93 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $1,042.93 629.35 409.08 4.50 doc: Receiot -06 Printed: 08 -15 -2011 INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 PERMIT NO. Project: F-0-5711.°,' PreeC46ykti4 Type of Inspection: & F, v61 / Address: / 47/4/fl 6-6 Au S Date Called: Special Instructions: Date Wanted: . 9 _ 9 -- / / .m. Requester: Phone No: c2c, 4 - v7g 3 7 ? ppFoved per applicable codes. I Corrections required prior to approval. COMMENTS: f/rarl (/�ta.Listo /#- /F' /:(/ ►4 / INS "ECTION FEE REQUI ° D. Prior to text inspection. fee must be 6300 Southcenter Blv' . Suite 100. all to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 0` (206) 431 -367b Permit Inspection Request Line (206) 431 -2451 Project: __Type of Inspection: Address: 1LUO I s Eb Stu S Date Called: Special Instructions: • Date Wanted: . 310—'11 . a:m . PP: Requester: Phone No: g0 (0 - LI-1 125 -3.73 _.. proved per applicable codes. a Corrections required prior to approval. COMMENTS: SPECTION FEE REQU ED. Prior to n t inspection, fee must be id at 6300 Southcenter Bl ., Suite 100. all to schedule rdinspectiion. _*i INSPECTION RECORD Retain a copy with permit INSPECTIONINO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 00, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projeat: Type of Inspectio :. /��,.,�-. Ad1re ;s:� O ( �� G T� Date Call n _ �j _ a/'� J� J� Special Instructions: Date Wa�nnted:. _ '.a7 &'2.Z - �� p•m Requester: • Phone N ire 4 - ' Approved per applicable codes. Corrections required prior to approval. COMMENTS: In¢pector: rate;Fs , 2 REINSPECTION FEE REQU ED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectioh. Permit No. Ply^ rpview approval is subject to errors and omissions. �;• • . •....�;i of cti ,'truction documents does not authorize fi : : tion y 0 opted code or ordinance. Receipt n ;ipproveo ' J el and conditions is acknowledged. By - -: ►, Date: S L91 Of 1L7 BU1= SE1 -, ;ATE PERMIT REQUIRED FOR: Eftechanical le'lectrical (Plumbing CiodSs Piping ii J of Tukwila DIVISION r----- No changes shah of work witho T ,,k,►ila Bt ,:.c /001 RE VISION be ma it prior hiding quire �`'ional kwila IVISION e to the scope pproval of ivision. new plan submittal 12n n,. irvi 56,t4 11-keS 7 REVIEWEd FO CODE COMPLIANC APPROVED AUG 172011 b City of Tukwila iUILDING DIVISIO i n k ?c 1 ,l ei;c .. Chure4 \4'o; S(0 ✓e S TvLy\cdA, (A/A- cig/(-r env b� AUG 15-201 qcur6"cl %Rpm ; qv! Ao-i- -r� SCetti Pit-25I Ileferrah Noure,c(--C ve_- Name -FO56e C c; Site 1410 h /0 Atte S City Zip cl% Billing phone ( phone ( phone ( email Date PO City Zip rpitz_. rtreMail LE= Sr.J Notes Perm It No. Pitch gable hip cut-up Layers metal built up Soffits open closed Recover Y N Style gable hip cut-up Gutters metal built up Spouts Y N Metal color inside outside Te.C.L.0 CYCP CZANAChki2. tiLA (2>el Ski ht. LqnpLik- C40111-c 4ZDY:tik. Co#j 3‘ak..24- sjL tA/.4-DLZ2 1\cd_v■J \tr.: C.A>k --Viv•Gjv.St. r\Q-VJ C-e)cN a9 (-0Qweak- U:'w\AAeD `5\1•6,,ks atA/4„52,2 c 0-v-vk Atk &2 (S a fr i n . 2 . 4 , C 4 , 6 b P Q Aly% k--D okl-Dp.s.AS c9I■c, c-A c)I \42(2-f Access bad OK good Pack in Y N Pack out Y N Power inside outside FIELD ST RIDGE RIDGE VENT VALLEY DRIP RVO PBK B001 8X12 3X5 5X13 REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 7 2011 S. City of Tukwila BUILDING DIVISION enylnik, TDG AUG 152011 scupPERPERMITCEMI FASCIA CAP DII V1 ./ Technical Data Sheet LANDMARKTM Premium Shingles LANDMARKTM Plus Shingles LANDMARK TM Shingles LANDMARK Prerniurn /ArchitectTM REVIEWED FOR CODE COMPLIANCE APPROVED AUG 18 2011 City of Tukwila 434PriR410(PWINNA CertainTeed SAIINT GOBAIN only) PRODUCT INFORMATION Landmark shingles reflect the same high manufacturing standards and superior warranty protection as the rest of CertainTeed's line of roofing products. Landmark Premium (and Algae Resistant -AR), Landmark Plus (and AR) and Landmark (and AR) are built with the industry's toughest fiber glass mat base, and their strict dimensional tolerance assures consistency. Complex granule color blends and subtle shadow lines produce a distinctive color selection. Landmark is produced with the unique NailTrakTM nailing feature. Please see the installation instruction section below for important information regarding NailTrak the Northwest (NVV) Region Landmark Premium (AR) is double - branded aikLandmarkilt Premium/Architect 80 (AR). - Landmark algae - resistant (AR) shingles have the additional attribute of resisting the growth of alga especially in damp regions. AR shingles are not available in all regions Colors: Please refer to the product brochure or CertainTeed website for the colors available in your region. Limitations: Use on roofs with slopes greater than 2" per foot. Low -slope applications (2" to 4" per foot) require additional underlayment. In areas where icing along eaves can cause the back -up of water, apply CertainTeed VVnterGuardT'" Waterproofing Shingle Underlayment, or its equivalent, according to application instructions provided with the product and on the shingle package. Product Composition: Landmark series shingles are composed of a fiber glass mat base. Ceramic - coated mineral granules are tightly embedded in carefully refined, water - resistant asphalt. Two pieces of the shingle are firmly laminated together in a special tough asphaltic cement. All Landmark shingles have self - sealing adhesive strips. to algae' Applicable Standards ASTM D3018 Type I ASTM D3462 ASTM E108 Fire Resistance: Class A ASTM D3161 Class F Wind Resistance ASTM D7158 Class H Wind Resistance UL 2390 /ASTM D6381 Class H Wind Resistance UL 790 Fire Resistance: Class A Technical Data: Weight/Square (approx.) Dimensions (overall) Shingles/Square (approx.) Weather Exposure Landmark (and AR) 235 -245 lb 13 1/4" x 38 3/4" 64 5 5/8" *includes °Landmark Premium AR/Architect 80" RECEIVED 08- 18 -'11 11:00 FROM- 2068299557 UL 997 Wind Resistance ICC Evaluation Report ESR -1389 NYC -MEA- 120 -79 -M (Regional) CSA Standard A123.5 -98 (8-05) (Regional) Ontario BMEC Auth. 97- 10-219 (Regional) Miami -Dade Product Control Approved Florida Product Approval # FL5444 (Regional) TDI Windstorm Resistance (Regional) Landmark Plus (and AR) 260 -280 lb 131 /4" x 38 3/4" 66 5 5/8" Landmark Premium" (and AR) 300 -330 lb 13 1/4" x 38 3/4" 66 5 5/8" TO- publicworks /dcd P002/004 I�Uy IV I I I I I GV IVIGUVI I`.....",1111111 y t LVV V L JV VV I Technical Data Sheet (Continued) Landmark Shingles Page 2 of 3 INSTALLATION Installation instructions, including diagrams, are supplied on each bundle of shingles, or separate application sheets may be obtained from CertainTeed. Following is a general summary of the installation methods. NOTE - Refer to application instructions supplied with the shingles for further information and procedures. Roof Deck Requirements: Apply shingles to minimum 3/8" thick plywood, minimum 7/16" thick non - veneer (e.g. OSB), or minimum 1" thick (nominal) wood decks. The plywood or non - veneer decks must comply with the specifications of APA -The Engineered Wood Association. Ventilation: Provisions for ventilation should meet or exceed current HUD Standards. To best insure adequate ventilation, use a combination of continuous ridge ventilation (using Ridge FillerVent or Ridge Filter ShingleVent II, manufactured by Air Vent Inc, or a comparable product with an external baffle) and balanced soffit venting. Valleys: Valley liner must be applied before shingles. The Closed -Cut valley application method is recommended, using CertainTeed WinterGuard Waterproofing Shingle Underlayment or its equivalent to line the valley prior to being fully covered by the shingles. Underlayment: On slopes 4" per foot or greater, CertainTeed recommends one layer of DiamondDeckT" Synthetic Underlayment, or Roofers' SelectTM High - Performance shingle underlayment, or shingle underlayment meeting ASTM D226, D4869 or ASTM D6757. Always ensure sufficient deck ventilation, and take particular care when DiamondDeck or other synthetic underlayment is installed. For UL fire rating, underlayment may be required. Corrosion - resistant drip edge is recommended and should be placed over the underlayment at the rake and beneath the underlayment at the eaves. Follow manufacturer's application instructions. On low slopes (2" up to 4" per foot), one layer of CertainTeed's WinterGuard Waterproofing Shingle Underlayrnent (or equivalent meeting ASTM 01970) or two layers of 36" wide felt shingle underlayment (Roofers' Select High - Performance Underlayment or product meeting ASTM D226, D4869 or ASTM D6757) lapped 19" must be applied over the entire roof, ensure sufficient deck ventilation. When DiamondDeck or other synthetic underlayment is installed, weather -lap at least 20" and ensure sufficient deck ventilation. When WinterGuard is applied to the rake area, the drip edge may be installed under or over WinterGuard. At the eave, when WinterGuard does not overlap the gutter or fascia, the drip edge should be installed under WinterGuard. When WinterGuard overlaps the fascia or gutter, the drip edge or other metal must be installed over it. Follow manufacturer's application instructions. Fastening (NailTrakT"): Low & Standard Slopes: On low and standard slopes, four nails are required per shingle. There are three nail lines on NailTrak shingles. Position nails vertically between the upper and lower nailing -guide lines. It is acceptable to nail between either the middle and lower lines or between the upper and middle lines. Nails must be of sufficient length to penetrate into the deck 3/4" or through the thickness of the decking, whichever is less. They are to be located 1" and 12" in from each side of the shingle (see instructions on product wraps.) Nails are to be 11 or 12 gauge, corrosion- resistant roofing nails with 3/8" heads. Steep Slopes: On slopes greater than 21" per foot, fasten each shingle with six nails and four 1" diameter spots of asphalt roofing cement (ASTM D4586 Type II) placed under each shingle according to application instructions provided on the shingle package. Fasteners must penetrate the two -layer common bond area that is indicated by the middle and lower NailTrak lines, also illustrated on the shingle package. RECEIVED 08- 18 -'11 11:00 FROM- 2068299557 TO- publicworks /dcd P003/004 Technical Data Sheet (Continued) Landmark Shingles Page 3 of 3 Application: The recommended application method is the 'Five- Course, Diagonal Method' found on each bundle of shingles. In this method, shingle course offsets are 6" and 11 ". Instructions also may be obtained from CertainTeed. These shingles may be used for new construction or for reroofing over existing Metric -sized shingles. Flashing: Use corrosion- resistant metal flashing. Hips and Ridges: For capping hip and ridge apply CertainTeed Shadow RidgeTM, Cedar Crest" or Mountain RidgeTU shingles of a like color. MAINTENANCE These shingles do not require maintenance when installed according to manufacturer's application instructions. However, to protect the investment, any roof should be routinely inspected at least once a year. Older roofs should be looked at more frequently. WARRANTY Landmark Premium (and AR), Landmark Premium /Architect 80, Landmark Plus (and AR), and Landmark (and AR) shingles carry a lifetime limited, transferable warranty to the consumer against manufacturing defects. In addition, Landmark Premium (and AR). Landmark Premium /Architect 80, Landmark Plus (and AR), and Landmark (and AR) carry 10 -years of SureStartTM Protection. For specific warranty details and limitations, refer to the warranty itself (available from the local supplier, roofing contractor or on -line at www.certainteed.com). FOR MORE INFORMATION Sales Support Group: 800 - 233 -8990 Web site: www.certainteed.com See us at our on -line specification writing tool, CertaSpec, at www.certainteed.com/certasoec. CertainTeed Roofing P.O. Box 860 Valley Forge, PA 19482 CO Copyright CertainTeed Corporation, 2011. All rights reserved. Updated: 07/2011 RECEIVED 08- 18 -'11 11:00 FROM- 2068299557 CertainTeed SAINT- GOSAIN TO- publicworks /dcd P004/004 �ERN�IT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -281 DATE: 08/15/11 PROJECT NAME: FOSTER PRESBYTERIAN CHURCH SITE ADDRESS: 14401 56 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: �0 Building l vision Public Works awn V'A e7�tIp- Fire Prevention Iti Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 08/16/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ' Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/13/11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping El PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople-ter Friendly Page General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name FRED MEYER ROOFING KLEENWAYS UBI No. 603122430 Phone 2064783733 Status Active Address 16468 Marine View Dr Sw License No. FREDMMR893M9 Suite /Apt. License Type Construction Contractor City Burien Effective Date 7/29/2011 State WA Expiration Date 7/29/2013 Zip 98166 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company FMR ENTERPRISES INC ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FREDMMR935C7 FRED MEYER ROOFING Construction Contractor General Unused 2/27/2007 2/27/2013 Re Licensed Business Owner Information Name Role Effective Date Expiration Date MEYER, ALFRED WILLIAM President 07/29/2011 MEYER, JENNIFER DAWN Vice President 07/29/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 Contractors Bonding & Insurance Co SE2073 07/12/2011 Until Cancelled $12,000.00 07/29/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 Burlington Ins Co HGL0026632 02/11/2011 02/11/2012 $1,000,000.00 07/29/2011 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 08/19/2011