Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-284 - COSTCO - TENANT IMPROVEMENT
COSTCO INTERIOR DEMO 400 COSTCO DR EXPIRED 05 -02 -12 Dl 1-284 City olkukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 2523049063 Address: 400 COSTCO DR TURIN Suite No: Project Name: COSTCO INTERIOR DEMOLITION Permit Number: D11 -284 Issue Date: 09/19/2011 Permit Expires On: 03/17/2012 Owner: Name: COSTCO WHOLESALE CORPORATIO Address: PROPERTY TAX DEPT 006 , 999 LAKE DR 98027 Contact Person: Name: BRIAN DOBRY Address: 1110 - 110 AV NE, STE 500 , BELLEVUE WA 98004 Contractor: Name: INTERSTATE CONST GROUP INC Address: 437 29 ST NE, SUITE F , PUYALLUP WA 98372 Contractor License No: INTERCG974QR Phone: 425 463 -2000 Phone: 253 - 435 -0949 Expiration Date: 11/19/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT: REMOVAL OF REFRIGERATION WALL AND CEILING PANELS, RELOCATE EXISTING FIRE ALARM SYSTEM TO PROVIDE COVERAGE AS REQUIRED BY CODE, AND REMOVE ALL ELECTRICAL AND LIGHTING IN ROOMS TO BE DEMOLISHED. Value of Construction: $206,617.00 Fees Collected: $3,889.67 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 011 -284 Printed: 09 -19 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N N N • • Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: Private: Profit: N Private: Date: End Time: Fill 0 c.y. End Time: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not construction or the pe • rman - of wo to this permit. Signa to give au rity to violate or cancel the provisions of any other state or local laws regulating attthorized to si•' and obtain this development permit d a• ee to the conditions attached Print Name: Date: This permit shall become null . d void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 6: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special doc: IBC -7/10 D11-284 Printed: 09 -19 -2011 inspection agency and shall be submitted to.Building Official prior to and as a condition -nal inspection approval. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. 9: All wood to remain in placed concrete shall be treated wood. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDMONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: Accumulation of combustible waste material is prohibited during the demolition phase of this project. Remove and properly dispose of all waste material prior to the close of the working day and as often throughout the day as needed. 17: Maintain coverage and operability of portable fire extinguishers, sprinkler systems and fire alarm systems during demolition and construction. 18: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 19: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 20: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 21: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -284 Printed: 09 -19 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.qov Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 400 Costco Drive, Tukwila, WA 98188 Tenant Name: Costco Wholesale Property Owners Name: Costco Wholesale Mailing Address: 999 Lake Drive King Co Assessor's Tax No.:� Suite Number: New Tenant: 2 Floor: ❑ Yes m ..No Issaquah, WA City 98102 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Brian Dobry Mailing Address: 1110 - 110th Avenue NE, Suite 500 E -Mail Address: brian.dobry@mulvannyg2.com Day Telephone: (425) 463 -2000 Bellevue WA 98004 City State Fax Number: (425) 463 -2095 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Interstate Construction Group, Inc. Mailing Address: 437 29th Street NE, Suite F Contact Person: Larry Prescott E -Mail Address: larry@ interstateconstructiongroup.com Contractor Registration Number: INTERCG974QR Puyallup, WA City State Day Telephone: (253) 435 -0949 Fax Number: (253) 435 -0953 Expiration Date: 11/19/2012 98372 Zip ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: MulvannyG2 Architecture Mailing Address: 1110 - 10th Avenue NE, Suite 500 Contact Person: Brian Dobry Bellevue, WA 98004 E -Mail Address: brian.dobry@mulvannyg2.com City State Day Telephone: (425) 463 -2000 Fax Number: (425) 463 -2002 Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: city Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application doe Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATION — 206 -431 -3670 Valuation of Project (contractor's bid price): $ 206,617.00 Existing Building Valuation: $ Scope of Work (please provide detailed information): Removal of existing refrigeration wall and ceiling panels, relocate existing fire alarm system to provide coverage as required by code, remove all electrical and lighting in existing rooms being demolished. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: * Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 786 Compact: Handicap: 16 Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Saf ty ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Permit Application :doe Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor 181,641 12,011 0 0 3 -B M 2nd Floor 3rQ Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: * Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: 786 Compact: Handicap: 16 Will there be a change in use? ❑ Yes m No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: m Sprinklers m Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Saf ty ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Permit Application :doe Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ER 0 " AU , ORIZED AG Signature: Date: 8 /(7 /,La I1 Print Name: Mostafa Ahanc i Day Telephone: 425.463.2000 Mailing Address: 1110 - 110 Avenue NE, Suite 500 Bellevuew WA 98004 IDate Application Accepted: TibIvtlu City State Zip Date Application Expires: H. \ Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised 7 -2010 bh N-7,11 1 I I1.-- Staff Initials: Page 6 of 6 i • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2523049063 Permit Number: D11 -284 Address: 400 COSTCO DR TUKW Status: APPROVED Suite No: Applied Date: 08/19/2011 Applicant: COSTCO INTERIOR DEMOLITION Issue Date: Receipt No.: R11 -02043 Payment Amount: $2,359.15 Initials: JEM Payment Date: 09/19/2011 12:39 PM User ID: 1165 Balance: $0.00 Payee: INTERSTATE CONSTRUCTION GROUP INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014637 2,359.15 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $2,359.15 2,354.65 4.50 doc: Receiot -06 Printed: 09 -19 -2011 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049063 Address: 400 COSTCO DR TUKW Suite No: Applicant: COSTCO WHOLESALE RECEIPT Permit Number: D11 -284 Status: PENDING Applied Date: 08/19/2011 Issue Date: Receipt No.: R11 -01815 Initials: User ID: Payee: JEM 1165 Payment Amount: $1,530.52 Payment Date: 08/19/2011 03:40 PM Balance: $2,359.15 ROBERT S BRAZIER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04504C ACCOUNT ITEM LIST: Description 1,530.52 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,530.52 Total: $1,530.52 doc: Receiot -06 Printed: 08 -19 -2011 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 0o'Srec Type of Inspection: - r/? Iiou G Address: 4/0 41 (to's? (1 d Date Called: �. Special Instructions: Date Wantedf� // /4/ a p.m. m. Requester: ./tl Phone No: o246 - —7/47—&33 7 11.A..p.proved per applicable codes. El Corrections required prior to approval. COMMENTS: IDay:///7/7/ EINSPECTION FEE RiQUIRED. Prig to next inspection, fee must be paid at 6300 Southcenter Blvd., Suit4 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit L ( l4` INSPEC ION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project -� Type of Inspection: ■ Address: ,., = ..JNSPECTION RECORD Retain a copy with permit INSPECTION No:. PERMIT NO. .zrY) go /i-z,9 V CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter.glvd.,. #100, Tukwila. WA 98188 filL, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Pioject: .' .• • Type of Inspection: Address: • . .. /BA. £'S7) ,),2 Date Called: Special Instructions: - . Date Wante :. /0 //3 �/ a.m p.m. Requester: Phone No: G246.... 7/x`633 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?4 Date: jj /6 /43 // IN ' ECTION FEE REQUIRED. P1or to. ext inspection, fee must be it 6300 Southcenter Blvd.. Suit 100. Call to schedule reinspection. ,13:1 INSPECTION RECORD Retain a copy with permit 01(464 INSPECTION'NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 re Project: rkr-1--i Type of pection: ■ Address: Od a c 4) j't c-o 4E. Date Called: --.. Special Instructions: r.. Date Wanted:. _ 4.m, I O _ (p (( p.m. 1 Requester: Phone No: 253 - 4210• -2.223 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: A-) mod. rkr-1--i (4 tr4 ` - a- ,` It. s ') `hvm -P or,( ofe_. 44;5' ^ w ,QM 1v SN J c7.) fr M. Cg-7 3L. (C v' S:4 p .f/AA;r ::_ OAP rin .6C/3 4 - `¢-lf S •71" Iffspeci'or: fl 1Date:10 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSPECT' N NO. PERMIT N0: CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 • Permit Inspection Request Line (206) 431 -2451 Q(0 -Z11 Projecti. Type of Inspectiop: Address: . ..:ss>.1 5S _ ...� ' Q 'r / Date Called: Date -�� Special Instructions: • ••Zo Date Wanted:. ..a m,;, / Q- (0 - 6 p.m. Requester: Phone No: (p -2SS- 3 (7/ JApproved per applicable codes. aCorrections required prior to approval. COMMENTS:, • - 5j &' ie cj-1/4 — -1--.. H 1 r, �✓ ' •0 J L1a - A-0 c-$6, , 4-- t z • ... 0 --= e,-0J k: -I 0 c E M 1 a J4, • ••• - RA`SI e_ Li kr-U , a V-- AtLibkoL/Pv • r Inspec r: Dater 0 ' t J ` REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER ,SPECTION RECORD Retain a copy with permit 0 — Ogf_. S.— PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: I Ca5 cv •\ Type of Inspection: ' Co 0.4:- Address' C6 Suite #: D2- Contact Person: Special Instructions: ' Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: SP .0 4-C / C gar ---- Needs Shift Inspection: •\ Sprinklers: Fire Alarm: f "Hood & Duct: Monitor: ' Pre -Fire: Permits: Occupancy Type: Inspector: /f- / .,)- -. - Date: 4/y /// Hrs.: f $100:b0 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: I Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • b • 4 ::J 04 -02 -2012 cif 0,x'7' ii Jim Haggerton, Mayor Department of Community Development BRIAN DOBRY 1110 -110 AV NE, STE 500 BELLEVUE WA 98004 RE: Permit No. D11 -284 COSTCO INTERIOR DEMOLITION 400 COSTCO DR TUKW Dear Permit Holder: Jack Pace, Director In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 05/02/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 05/02/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, GOO? er Marshall t Technician File: Permit File No. D11 -284 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 MU LVANNYj 12 September 2011 • G2 DESIGN AT WORK Dave Larson Senior Plans Examiner City of Tukwila 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 Re: Tenant Improvement - Southcenter Costco 400 Costco Drive Tukwila, WA 98188 Project Number: 93- 0440 -25 Subject: Permit Comment Response Dear Mr. Larson: Please find this to be our response to your letter received 7 September 2011, and Memo dated 30 August 2011, requesting additional information for the permit submittal for the tenant improvement at the above mentioned site. Items: 1. Code references on the plan cover sheet need to be changed to 2009 instead of 2006 except Electrical, 2008 is ok. See attached transmittal, and TS1.01 sheet with revision date of 13 September 2011, and item clouded and corrected. 2. A long thin room is being created along grid A.4 and between 1.9 and 4.3. Please label this room for its use. - See attached transmittal, and A1.01 sheet with revision date of 13 September 2011, and item clouded. 3. The floor plans should include a scale to review exiting. Please add scale to sheet A1.01 and A1.02. - See attached transmittal, and A1.01 and A1.02 sheets with revision date of 13 September 2011, and item clouded. CORRECTION 425.463.2000 425.463.2002 1110 112TH AVENUE NE I SUITE 500 I BELLEV MulvannyG2.com iECEIVEf SEP 12 2011 Tenant Improvement - Southcenter Costco 12 September 2011 Page 2 of 2 4. Please provide typical wall cross - sections for all new wall types and wall infills. Include fasteners and spacing for top and bottom tracks. See attached transmittal, and A1.02 sheet with revision dated 13 September 2011 and showing wall cross section and details, and item clouded. 5. Please remove the word demolition from the cover page of the plans and permit application and use the term "Tenant Improvement ". The addition of new walls and infills make this a tenant improvement permit. Other references to demolition are OK when describing scope of work. Demolition Permits imply removal only. - See attached transmittal and TS1.01 sheet with revision dated 13 September 2011 and showing change of title to "Tenant Improvement ", and item clouded. Should you require any additional information regarding this matter, please contact me at 425.463.1616. Thank you. Sincerely, c _ �1 Brian Dobry Associate BD /bsd c: MulvannyG2 Architecture /briand document2 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 7, 2011 Brian Dobry MulvannyG2 Architecture 1110 10`h Av NE, Suite 500 Bellevue, WA 98004 RE: Correction Letter #1 Development Permit Application Number D11 -284 Costco Interior Demolition — 400 Costco Dr Dear Mr. Dobry, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D11 -284 W:\Permit CenterCorrection Letters\2011\D11 -284 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila.- 3uilding Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: August 30, 2011 Project Name: Costco Permit #: D11 -284 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. 1. Code references on the plan cover sheet need to be changed to 2009 instead of 2006 except Electrical, 2008 is ok. 2. A long thin room is being created along grid A.4 and between 1.9 and 4.3. Please label this room for its use. 3. The floor plans should include a scale to review exiting. Please add scale to sheet A1.01 and A1.02. 4. Please provide typical wall cross - sections for all new wall types and wall infills. Include fasteners and spacing for top and bottom tracks. 5. Please remove the word demolition from the cover page of the plans and permit application and use the term "Tenant Improvement ". The addition of new walls and infills make this a tenant improvement permit. Other references to demolition are OK when describing scope of work. Demolition Permits imply removal only. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • • PE e q COPV PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -284 DATE: 09 -12 -11 PROJECT NAME: COSTCO INTERIOR DEMOLITION SITE ADDRESS: 400 COSTCO DR Original Plan Submittal X Response to Correction Letter # 1 Revision # After Permit Issued Response to Incomplete Letter # PART ENT ui ding Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 09 -13 -11 Complete Incomplete ❑ Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10 -11 -11 Approved Approved with Conditions IX/ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 *)13ERM1T COORD COM1101 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -284 DATE: 08/19/11 PROJECT NAME: COSTCO INTERIOR DEMOLITION SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued E A THE TS' qq�� j �Vi ��tl B it ing ivi ion »J/+- e \ Public Works ire Prevention Structural -lrc El (Vi On .40 Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1X1 Comments: Incomplete DUE DATE: 08/23/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route T/y, REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 09/20/11 Not Approved (attach comments) NI DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 9 -i-'' Bldg'- Fire ❑ Ping ❑ PW ❑ Staff Initials: w: Documents /routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: September 12, 2011 Plan Check/Permit Number: D11 -284 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Cosco Interior Demolition 400 Costco Drive Brian Dobry Phone Number: (425) 463 -2000 Summary of Revision: Updates to TS1.01: Code reference change from 2006 to 2009 for IBC "Tenant Improvement" as title verses Demolition Updates to A1.01: Title and Scale reference for plan Updates to A1.02: Title and Scale reference for plan, Room designation, Update to Key Notes, Detail Marks at interior elevation, Details for wall and infill wall attachments. ,(7: CNS ti 1KWILA Sheet Number(s): TS1.01, A1.01, A1.02 "Cloud" or highlight all areas of revision including dat rev' ii Received at the City of Tukwila Permit Center by: Entered in Permits Plus on SEP122011 lEa \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: 1 -2009 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company INTERSTATE CONST GROUP INC 2534350949 437 29Th St Ne, Ste F Puyallup WA 98372 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602339476 Active INTERCG974QR Construction Contractor 11/19/2003 11/19/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PACIFIF915DU PACIFIC INTERSTATE FCLTY CNTRS Construction Contractor General Unused 3/31/2009 3/31/2011 Expired Business Owner Information Name Role Effective Date Expiration Date PRESCOTT, LARRY President 11/19/2003 Amount LORENZ, KENNETH Vice President 11/19/2003 G24099945002 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SF2715 11/13/2003 Until Cancelled $12,000.00 11/19/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 WESTCHESTER G24099945002 11/18/2009 11/18/2011 $1,000,000.0011 /18/2010 FIRE INS 6 CHARTER OAK FIRE INS CO 526D990000F 11/18/2007 11/18/2009 $1,000,000.00 10/29/2008 5 GREAT GLP9252761 11/18/2007 11/18/2008 $1,000,000.00 11/08/2007 AMERICAN INS GREAT 4 AMERICAN E & S GL0566441903 11/18/2006 11/18/2007 $1,000,000.00 11/09/2006 INS CO 3 GREAT AMERICAN E & 5 GL05664419- 02 11/18/2005 11/18/2006 $1,000,000.00 11 /18/2005 INS CO GREAT 2 AMERICAN E & S GL0566441901 11/18/2004 11/18/2005 $1,000,000.00 11/02/2004 INS CO Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/19/2011 FILE COPY Now V 1.1-- E CAPSTCO WHOLESALE TUKWILA, WA #06 400 COSTCO DRIVE TUKWILA, WA 98188 1Pennit ��� Flan maw :.4 R,4 : 1/111110LESAIL - of construction documents ile *WM of any does not authorize COd@t, ,, .. ; Y, :. . COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 WWW.costco.com kA A I. • -; U KW I A WA flit yofTu►�I A BUILDDA DIVISION I N R OR NAN IMPROV M N, _A, __A_ _ _ _ . -- - '. SITE PLAN PROJECT NOTES DRAWING INDEX DATA THESE PROJECT GENERAL NOTES APPLY TO THE ENTIRE PROJECT. CONSULT DRAWINGS OTHER THAN ARCHITECTURAL FOR ADDITIONAL GENERAL NOTES, ABBREVIATIONS AND SYMBOLS. FIRE PROTECTION /ALARM DRAWINGS TO BE SUBMITTED AS A DEFFERED SUBMITTAL. FIELD VERIFICATION AND COORDINATION: DRAWING INDEX TS1.01 TITLE SHEET & SITE PLAN A1.01 BUILDING DEMOLITION PLAN A1.02 FLOOR PLAN REVIEWED FOR CODE COMPLIANCE APPROVED SEP 1 5 20 1 City of U Ise BUILDING VISION ' EXIST. BUILDING DATA: EXIST. BUILDING AREA 176 967 S.F. EXIST. TIRE CENTER 4,674 S.F. 1110 112TH AVE. NE I SUITE 500 I Q` o Itt / ; 57% \ r I ns G EXI,ST. TOTAL BUILDING 181 641 S.F. �+ ' EXIST. OPTICAL FACILITY 34,544 S.F. BELLEVUE WA 1 98004 I ■ No /, ' 1. SURVEY DIMENSIONS: DIMENSIONS OF SITE CONDITIONS ARE FROM SURVEY BY OTHERS. THE ARCHITECT BEARS NO RESPONSIBILITY FOR ACCURACY OF SAME. 2. EXISTING UTILITY LOCATIONS: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF THE SIZE HAVE LOCATION OF ALL EXISTING ED FROM AVAILABLE REOCORDS AND AORE SHOWN GROUND UTILITIES. ICONVENIE CONVENIENCE ONLY. THE SHOWN CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ADDITIONAL UTILITY LOCATIONS NOT SHOWN. CARE SHOULD RESPONSIBLE FOR REPAIRING ANY DAMAGE TO THE UTILITY. UTILITIES. THE CONTRACTOR SHALL BE 3. THE CONTRACTOR SHALL CONSULT THE DRAWINGS OF ALL TRADES FOR OPENINGS THROUGH SLABS, WALLS CEILINGS, AND ROOFS FOR DUCTS PIPES, CONDUIT CABINETS AND EQUIPMENT AND SHALL VERIFY THE SIZES AND LOCATIONS WITH SUBCONTRACTORS. 4. THE CONTRACTOR SHALL BE AWARE OF ANY CONDUIT, PIPING, OBSTRUCTIONS, AND ATTACHMENTS UNDER THE ROOF, AND SHALL AVOID DURING CONSTRUCTION /RE -ROOF. DIMENSIONS: t 425.463.2000 I f 425.463.2002 ( / I ir j i i I j j i a / iy PARKING DATA. PARKING PROVIDED ' ®10 WIDE STALLS 677 STALLS 2 9' WIDE STALLS 74 STALLS HANDICAP STALLS 15 STALLS # HC �J MulvannyG2.com PROJECT DESCRIPTION v .7 \ \fl �I / v 0 ISSUE FOR PERMIT V %) % i ! SCOPE OF WORK INCLUDES: REMOVAL OF EXISTING REFRIGERATION PANEL WALLS AND ROOF, AND ELECTRICAL WIRING AT EXISTING OPTICAL DISTRIBUTION. REMOVE AND RELOCATE EXISTING FIRE ALARM SYSTEM TO PROVIDE COVERAGE AS PER CODE. INFILL EXISTING OPENINGS IN EXISTING CONCRETE BLOCK WALL AND REFRIGERATION WALL AS SHOWN. PATCH AND REPAIR FLOOR AS NECESSARY DUE TO CONSTRUCTION AND DEMOLITION: �I�I��I'- i I 0� �// .,.•. ,. ., LI " " -- - "1 I / I U � .-9119 I Ela,_I_I_I_1_1_1_1 �o j !!1 ENTRANCE Cosirco EXIST. TIRE INSTALLATION 77:77/9/ .7 S EXIST. TOTAL PARKING 766 STALLS NO OF STALLS PER 1 000 S.F. OF BUILDING AREA. 3.61 STALLS EXpi NAY o RIE 2. 2012 ' ¢ �� �� RECEIVING 1. DO NOT SCALE THE DRAWINGS TO OBTAIN DIMENSIONS. WRITTEN DIMENSIONS GOVERN. USE ACTUAL FIELD MEASUREMENTS. NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 2. DIMENSIONS ARE TO THE: - CENTERLINE OF COLUMNS OR GRID -FACE OF STUDS OPENINGS -FACE OF CONCRETE OR MASONRY (NOMINAL) 3. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS OR DETAILS SHALL BE 6" FROM THE FACE OF INTERSECTING WALL TO EDGE OF DOOR OPENING. 4. ALL DIMENSIONS NOTED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF ALL FINISHES INCLUDING CARPETING, TILE, AND TRIM. 5. ALL HEIGHTS ARE DIMENSIONED FROM THE TOP OF THE SLAB UNLESS NOTED OTHERWISE. 6. ROUGH IN DIMENSIONS: VERIFY ALL ROUGH -IN DIMENSIONS FOR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE CONTRACTOR, SUBCONTRACTORS, OWNER OR OTHERS. GENERAL REQUIREMENTS: 1. VERTICAL CLEARANCES: PLACE NO MAINS, PIPING, CONDUIT OR OBSTRUCTIONS OF ANY KIND SO AS TO IMPAIR GIVEN CEILING HEIGHTS AND CLEARANCES. 2. IMPACT TO EXISTING OPERATIONS OF WAREHOUSE SHALL BE KEPT TO A MINIMUM. CONSTRUCTION AFTER BUSINESS HOURS REQUIRED IF TEMPORARY DISCONNECT OF UTILITIES SUCH AS ELECTRICITY, GAS, WATER, SANITARY AND SEWAGE. GOVERNING AUTHORITY REQUIREMENTS: SCOPE OF W O R F IL) , PROJECT CONSISTS OF: 1. LOCATE, TRACE BACK TO SOURCE AND DISCONNECT ALL ELECTRICAL IN AREA OF WORK. 2. REMOVE EXISTING REFRIGERATION PANELS AND CEILING. 3. RELOCATE EXISTING FIRE ALARM SYSTEM TO PROVIDE COVERAGE AS REQUIRED BY CODE. 4. GRIND DOWN EXISTING RAISED CONCRETE SLAB, AND PROVIDE NEW TOPPING COAT TO MATCH ADJACENT EXISTING FINISH. 5. INFILL EXISTING DOOR OPENING AT REMAINING REFRIGERATION WALL WITH SALVAGED PANELS. 6. PROVIDE NEW PARTITION AND INFILL AS SHOWN AT EXISTING CMU WALL NOTES: EXISTING CONDITIONS TO BE FIELD VERIFIED. ®�� / J 1 r ®� 7T! /TTi /-1T/ PTT 7•rr/ / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 'TIP i 77'7 terry /Tri , , / / / / / / / / / / / / / / / / / / / /// / / / / % / / / / / / / / / / / / / /// // / / / / / / / / / / / / / / / / /// / /// / / / / / / / / / / / / / / / /// / /// ��� �..c.4.� t.� Lc.c /LG // /////////// ° g////////// I //////// ii m V I C I NITY M/ Q __ .I �� ! P , , , /-ter o \P .� _ I II , ,-1 , , _ _ = -' I SAXON DRIVE _ a PROJECT DIRECTORY • 0 ,, � I �� ►- ' III p • . = (.9); ®,, ®c _ _ - 4 5 0 TUKWILA PKWY W. VALLEY HWY I z �, � q � I e --- _ �� 11-114 - - -- � ���" u ARCHITECT MULVANNYG2 ARCHITECTURE 1110 112TH AVE. N.E. SUITE 500 BELLEVUE, WA 98004 T: (425) 463.1576 F: (425) 463.2129 PROJECT MANAGER: BRIAN DOBRY FIRE NRG FIRE CONSULTING, LLC PROTECTION 650 NW 54TH STREET SEATTLE, WA 98107 T: (206) 789 -0165 PROJECT CONTACT: SEAN PISONI , EXISTING E !F; _ - - -° � - I - - -I �! \ I 1. COWNER a. W IZ 1- Z W W 0 0 = 0 I- Z D < co )VER PKWY E. 1�I - " - 2009 UNIFORM PLUMBING CODE INCLUDING LOCAL AMENDMENTS 2009 WASHINGTON STATE ENERGY CODE 2. OCCUPANCY CLASSIFICATION: GROUP ' M (MERCANTILE) 3. EXISTING BUILDING CLASSIFICATION: TYPE 3 -B FULLY SPRINKLERED Nr 1 °` t a I O1• C K 0 0 r o to 20' 40' 80' AREA OF WORK IS SHOWN AS HATCHED 0 Z < COSTCO EXISTING SITE PLAN IBUILDINGDory kSEPARATE PERMIT REQUIRED FOB Et Mithenical 41 el ti Plumbing � la Gas PIpkg ii.„1, SAXON D R. S. 180TH RUSSELL H. HAZZARD, ARCHITECT � REVISIONS � � shalt ae made to tn� SCALE: NOT TO SCALE ` of work without prior gppr01v81 Tukvr��a Building Owision- I�3T"�:.: Rev=sions wl'N requires nllw plan sl�l and may include additional pOan review fees. 0 MulvannyG2 All rights reserved. reproduced in any permission in writing 8079 REG ,TEREO f TECT ri RUS � " H. HAZZARD STATE tF WASHINGTON Architecture: No part of this document may be form or by any means without from MulvannyG2 Architecture. FOR ADDITIONAL ABBREVIATIONS: SEE OTHER DESIGN DISCIPLINES ARCHITECTURAL ABBREVIATIONS AND A6.01 ARCHITECTURAL SYMBOLS . ACOUS ACOUSTICAL ENCL ENCLOSURE LIQ LIQUID QT QUARRY TILE TEMP TEMPERED GLASS ADJ ADJUSTABLE, ADJACENT EQ EQUAL MAS MASONRY QTR QUARTER TYP TYPICAL AFF ABOVE FINISHED FLOOR (SLAB) EXH EXHAUST MAX MAXIMUM R RADIUS UTIL UTILITY ALUM ALUMINUM EXIST EXISTING MBS METAL BUILDING SUPPLIER RC REFRIGERATION CONTRACTOR UBC UNIFORM BUILDING CODE ANOD ANODIZED EXI EXPANSION MECH MECHANICAL RCP REFLECTED CEILING PLAN UNO UNLESS NOTED OTHERWISE APPROX APPROXIMATE EXT EXTERIOR MFG MANUFACTURING RD ROOF DRAIN VCT VINYL COMPOSITION TILE BD BOARD FD FLOOR DRAIN MFR MANUFACTURER RL RAIN LEADER VERT VERTICAL BFF BELOW FINISHED FLOOR (SLAB) FDN FOUNDATION MH MANHOLE RECD RECEIVED VIF VERIFY IN FIELD BLDG BUILDING FF FACTORY FINISH MIN MINIMUM REFRIG REFRIGERATION W/ WITH BLK BLOCK FHS FLAT HEAD SCREW MIP METAL INSULATED PANEL REINF REINFORCING W/0 WITHOUT BLK'G BLOCKING FL FLOOR MISC MISCELLANEOUS REQ'D REQUIRED WD WOOD BM BEAM FIO FURNISHED AND INSTALLED BY OWNER MO MASONRY OPENING RO ROUGH OPENING WDW WINDOW BOT BOTTOM FIN FINISH MR MOISTURE RESISTANT SCHED SCHEDULE WHS WELDED HEAD STUD BTWN BETWEEN FRPP FIBER REINFORCED PLASTIC PANEL(S) MULL MULLION SC SOLID CORE WP WATERPROOF O CB CATCH BASIN FRT FIRE RETARDANT TREATED MTD MOUNTED SHT SHEET WR WATER RESISTANT CG CORNER GUARD FTG FOOTING MTG MOUNTING SIM SIMILAR WT WEIGHT CI CAST IRON GA GAUGE MTL METAL SIO SUPPLIED AND INSTALLED BY OWNER WWF WELDED WIRE FABRIC CIP CAST IN PLACE GALV GALVANIZED NIC NOT IN CONTRACT SIV SUPPLIED AND INSTALLED BY VENDOR YD YARD DRAIN CL CENTER LINE GC GENERAL CONTRACTOR NOM NOMINAL SOIC SUPPLIED BY OWNER INSTALLED BY CLR CLEAR GWB GYPSUM WALLBOARD, GYPSUM NTS NOT TO SCALE CONTRACTOR CLG CEILING HB HOSE BIBB OA OVERALL SOIV SUPPLIED BY OWNER INSTALLED BY CMU CONCRETE MASONRY UNIT HC HANDICAPPED OC ON CENTER VENDOR COLUMN HM HOLLOW METAL OD OVERFLOW DRAIN SQ SQUARE CONC CONCRETE HORIZ HORIZONTAL OH OVERHEAD . SS SERVICE SINK, SANITARY SEWER CONT CONTINUOUS HP HIGH POINT OP 'G OPENING SST STAINLESS STEEL CONSTR CONSTRUCTION HT HEIGHT OPP OPPOSITE STD STANDARD CONTR CONTRACTOR HTR HEATER 0 TO 0 OUT TO OUT STL STEEL CT CERAMIC TILE HVAC HEATING, VENTILATION, AND AIR PTN PARTITION STRUCT STRUCTURE, STRUCTURAL DBL DOUBLE CONDITIONING PERP PERPENDICULAR SUSP SUSPENDED DIM DIMENSION IBC INTERNATIONAL BUILDING CODE PL PLATE, PROPERTY LINE SYS SYSTEM DTL DETAIL INSUL INSULATION PLASLAM PLASTIC LAMINATE T TREAD, TOP DF DRINKING FOUNTAIN INT INTERIOR PLYWD PLYWOOD TOJ TOP OF JOIST DS DOWNSPOUT JT/JTS JOINT, JOINTS PLBG PLUMBING TOM TOP OF MASONRY DWG DRAWING L LONG, LENGTH PNL PANEL, PANELING TOP TOP OF PARAPET EA EACH LAM LAMINATE, LAMINATED PR PAIR TOS TOP OF STEEL EFS EXTERIOR FINISH SYSTEM LF LINEAR FOOT PROJ PROJECT TOW TOP OF WALL EIFS EXTERIOR INSULATION AND FINISH SYSTEM LP LOW POINT PRV PRESSURE REDUCING VALVE T&B TOP AND BOTTOM ELEV ELEVATION LT FIXT LIGHTING FIXTURE PT PRESSURE TREATED TEL TELEPHONE ELEC ELECTRICAL LTWT LIGHT WEIGHT SYMBOLS MATERIALS REFLECTED CEILING WALL TYPES /� DATE DESCRIPTION DETAIL NORTH ARROW REVISION CLOUD AND DELTA ITEM SIO OR NIC i i I I I ACOUSTICAL TILE SUSPENDED CEILING GRID CMU TO -0" AFF WITH METAL BUILDING __ SYSTEM W/ LAY IN PANELS - SYSTEM TO TOP OF PARAPET 4' X 2' UNO 08.17.11 Permit Release DETAIL IDENTIFICATION PROJECT NORTH INDICATOR 1- 1 CUT LINE - DEFINES THE a Mk TRUE NORTH INDICATOR © I I 1 09.13.11 BUILDING DEPT. CORRECTIONS % %/ ALUMINUM DETAILED ELEMENT L J ® ,, A7.01 SHEET WHERE DRAWN ITEM SOIC OR SIC A CMU OR BRICK .. • ..... , . SHADED AREA DENOTES METAL CONCRETE WALL SECURITY DECK ABOVE ............ DOOR MARK WALL SECTION DOOR NUMBER - WORK, CONTROL OR DATUM POINT O ..:: '1 CONCRETE • SPRINKLER DROP 3 5/8" METAL STUDS UNO AT 16" OC WITH GWB - PAINTED EACH FACE UNO PER SCHEDULE DETAIL IDENTIFICATION REFER TO SCHEDULE 50' -0" AFF �! iii i-°:1i EARTH .. CUT LINE - DEFINES THE NEW CONSTRUCTION -SHOWN SOLID DETAILED ELEMENT WINDOW, RECITE OR DROP r EIFS Q CORD (SEE ELECT) 3 5/8" METAL STUDS AT 16" OC WITH SOUND ® AIR HOSE INSULATION BATTS AND FINISH PER SCHEDULE SLOPE DIRECTION WITH DATUM __a A7.01 LOUVER MARK SHEET WHERE DRAWN WINDOW NUMBER - MARK ((SLOPE DOWN 118" �] J(�� FINISHED WOOD REFER TO SCHEDULE PER FOOT Y \\ \\ BUILDING SECTION GRAVEL" y • `' " "' "' "' ' " '°' " " -" " " " """'" " ' DETAIL IDENTIFICATION SPRINKLER MAIN EQUIPMENT MARK -" ® WATER DROP METAL INSULATED PANELS EXHAUST VENT OR RETURN FREEZER / COOLER WALLS (SIO) / 93- 0440 -25 PM. KEVIN KOTAN DRAWN: bsd AUGUST 17, 2011 6 0 EQUIPMENT NUMBER - EXISTING CONSTRUCTION TO REMAIN - •. :.. •COL GYPSUM BOARD / FRPP A3.01 REFER TO SCHEDULE SHOWN LIGHT BACKGROUND SHEET WHERE DRAWN PROPERTY LINE IN ELEVATIONS i iiimfii INSULATION - BATT AIR GRILLE ,,�, .:. ... . ,.. »....- <.. ROOM MARK .. . NI .. o [ '� HUAC DIFFUSER EXTERIOR ELEVATION Roots ROOM NAME -- DETAIL IDENTIFICATION 100 I- --ROOM NUMBER FENCE INSULATION -RIGID RECEIVED TITLE SHEET "TS-1_ 01 O x x x x x x x "- INSULATION -SOUND FLUORESCENT LIGHTING- rtON �ORRE 12 2011 COLUMN GRIDS EXISTING CONSTRUCTION TO BE REMOVED - A3.02 COLU G $ SHEET WHERE DRAWN BREAKLINE SHOWN DASHED FIXTURE SEP FLUORESCENT LIGHTINGLTR# FIXTURE PERMIT CENTER PLYWOOD - - - INTERIOR ELEVATION 0 DETAIL IDENTIFICATION _ ID �I STEEL /� INCANDESCENT OR HID i i LIGHTING FIXTURES 24 I.- I WOOD BLOCKING b 1 I got- 2. 8 SHEET WHERE DRAWN WOOD MEMBER n .I 3 115' STEEL' .. 15' STEELI 5 ABOVE EXISTING • OPTICAL . PACKAGING • EXISTING OPTICAL PACKAGING mmn 5 = _TTT1 I EXISTING ELECTRICAL PANELS TO BE REMOVED I 1 I I EXISTING OPTICAL PACKAGING L EXISTING OPTICAL SORTING 6 6 ABOVE ABOVE EXISTING PRODUCE COOLER e EXIST. TRANSFORMER TRANSFORMER FIRE PROTECTION STAND PIPES FIRE HYDRANT GAS VALV EXISTING CMU WALL TO REMAI OFFICE USDA OFFICE 15' STEEL SUPPLY AREA COMPACTOR TELEPHONE CLOSET BALER /COMPACTOR ROOM WATER METER WATER VALVE BATTERY CHARGER MAINTENANCE ELECT. J =OX JANITOR 1ST. TRANS. PARTIAL DEMOLITION FLOOR PLAN SCALE: 1 /16 " =1' -0" EXP1REu MAY 022012 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 15 2011 City of Tukwila BUILDING DIVISION DEMOLITION KEY NOTES GENERAL NOTES BUILDING STATISTICS EGRESS SUMMARY 2 5 6 8 9 REMOVE REFRIGERATION PANELS. SEE OPERATION NOTES #3 & #4 DEMOLISH CMU WALL SEE OPERATION NOTES #1, #2, #3, #4, #6 AND #7. REMOVE STEEL RACKS AND ANCHOR BOLTS EMBEDDED IN CONCRETE FLOOR. SEE OPERATION NOTES #3 AND #4. - DEMOLISH STUD FRAME WALL. SEE OPERATION NOTES #1, #2, #3, #4, AND #6. DEMOLISH GYP BD. WALL ABOVE REFRIGERATION PANELS TO DECK ABOVE. REMOVE REFRIGERATION ROOF PANELS AND ASSOCIATED FIRE SPRINKLERS AND LIGHTING. SEE OPERATION NOTES #2, #3 AND #4. RAISED CONCRETE FLOOR AT PACKAGING ROOM TO BE CUT, GROUND DOWN AND RECEIVE SURFACE/SKIM CONCRETE COAT TO MATCH ADJACENT SLAB LEVEL. ALTERNATE TO REMOVE AND REPLACE CONCRETE IN THIS AREA. CONCRETE CURB AT GRIDLINE 'B' TO BE REMOVED. REMOVE DOOR HARDWARE AND AUTOMATED /ELECTRIC CLOSURE. LIGHTING TO BE LOCATED, TRACED TO SOURCE, DISCONNECTED AND REMOVED. RELOCATE AS NECESSARY EXISTING ELECTRICAL PANELS AND CIRCUITS. FIRE SPRINKLER SYSTEM TO BE ISOLATED DURING DEMOLITION OF REFRIGERATION ROOF PANELS, AND TO REMAIN IN PLACE AFTER REMOVAL. DEMOLITION & REMODEL CONSTRUCTION GENERAL NOTES THE BUILDING WILL BE OCCUPIED AND IN FULL USE BY THE OWNER DURING CONSTRUCTION. 1. CONSTRUCTION THAT MAY AFFECT THE PUBLIC SHALL BE DONE DURING OFF -HOURS 2. AREAS OF DEMOLITION SHALL INCLUDE, BUT ARE NOT LIMITED TO, ANY STRUCTURAL, PLUMBING, ELECTRICAL, MECHANICAL, FIRE SPRINKLER, ETC. ITEMS NECESSARY TO COMPLETE THE DEMOLITION WORK. THE CONTRACTOR IS TO REMOVE ALL WALLS, BOLLARDS, MISC. STEEL, PLUMBING, ELECTRICAL, RAISED CONCRETE SLAB, CURBS, REBARS, ETC. ASSOCIATED WITH DEMOLITION OF AREAS. SHOWN. 3. ALL REMOVED ITEMS NOT DESIGNATED FOR REUSE SHALL BE OFFERED IN GOOD CONDITION TO THE OWNER. DURING THE BIDDING PERIOD, COORDINATE AND VERIFY WITH THE OWNER AS TO WHICH ITEMS ARE TO BE SALVAGED. 4. DO NOT INTERRUPT ANY SERVICES (WATER, PLUMBING, FIRE SPRINKLER, ETC.) WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER. 5. MAINTAIN FIRE SPRINKLER AND FIRE ALARM SYSTEM IN OPERATING CONDITION AT ALL TIMES. NOTIFY THE OWNER AND COORDINATE AT LEAST 48 -HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING THE FIRE SPRINKLER OR FIRE ALARM SYSTEMS. PROVIDE FIRE -WATCH AS REQUIRED BY THE JURISDICTION. 6. PROVIDE AND MAINTAIN EGRESS PATHS THROUGHOUT CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EXIT SIGNS, LIGHTING, FIRE SPRINKLERS, ETC. OBTAIN FIRE MARSHAL APPROVAL PRIOR TO CLOSING ANY EGRESS OPENINGS AND /OR EGRESS PATHS DURING DEMOLITION /CONSTRUCTION. 7. THE CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND UTILITIES WITHIN PROXIMITY OF THE WORK AREA PRIOR TO EXCAVATION. AVOID CUTTING EXISTING CONDUIT OR PIPE EMBEDDED WITHIN FLOOR SLAB OR DIRECTLY BENEATH FLOOR SLAB, LASER SCAN OR SIMILAR METHOD SHALL BE CONDUCTED BY CONTRACTOR PRIOR TO CUTTING CONCRETE FLOOR. 8. PROVIDE TEMPORARY DUST PARTITIONS AS REQUIRED TO PREVENT DUST AND DEBRIS FROM SETTLING ON ADJACENT AREAS NOT UNDER CONSTRUCTION. REVIEW WITH AND OBTAIN OWNER'S APPROVAL FOR LOCATIONS. 9. THEiCONTRACTOR IS RESPONSIBLE FOR REPAIRING OR REPLACING ITEMS DAMAGED DURING DEMOLITION AND CONSTRUCTION. 10. WHEN CUTTING AND PATCHING, THE CONTRACTOR SHALL USE METHODS LEAST LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING SURFACES. CUT HOLES AND SLOTS AS SMALL AS PRACTICAL/POSSIBLE, NEATLY TO SIZE REQUIRED AND WITH MINIMUM DISTURBANCES OF ADJACENT MATERIALS. 11. WHERE EXISTING CONSTRUCTION IS REMOVED, CUT OR OTHERWISE DISTURBED, PATCH TO MATCH THE EXISTING ADJACENT SURFACES. SEAMS TO BE AS INVISIBLE AS PRACTICAL. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, ETC. 12. WHERE NEW WORK ABUTS OR ALIGNS WITH EXISTING, PERFORM A SMOOTH AND EVEN TRANSITION. PATCHED WORK TO MATCH EXISTING ADJACENT WORK IN TEXTURE AND APPEARANCE. 13. REMOVE AND REPLACE AREAS, SURFACES OR ITEMS THAT CANNOT BE SATISFACTORILY PATCHED. 14. AS A MINIMUM, THE LEVEL OF WORKMANSHIP SHOULD MATCH THE GENERAL LEVEL OF EXISTING WORKMANSHIP. 15. WHERE REQUIRED, TRIM EXISTING WOOD DOORS AS NECESSARY TO CLEAR FLOORING. SEAL CUT EDGES. 16. UNLESS SHOWN ON THE DRAWINGS OTHERWISE, DO NOT SUPPORT OR SUSPEND ITEMS, EQUIPMENT, HANGERS, ETC. FROM EXISTING STRUCTURAL MEMBERS (BEAMS, TRUSSES, JOIST, ETC.) WITHOUT WRITTEN APPROVAL OF A LICENSED STRUCTURAL ENGINEER. 17. DO NOT CUT OR DRILL ANY STRUCTURAL MEMBER (PARTICULARLY ROOF JOIST) WITHOUT WRITTEN APPROVAL OF A LICENSED STRUCTURAL ENGINEER. 18. SHORING OF STRUCTURAL. FOUNDATIONS, STRUCTURES, AND /OR TRENCHING REQUIRED TO COMPLETE THE WORK DESCRIBED IN THE DOCUMENTS IS CONSIDERED A MEANS, METHOD OR TECHNIQUE AND IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IF A REGULATORY AGENCY REQUIRES A LICENSED ENGINEER TO SUPERVISE, APPROVE, AND /OR PROVIDE DRAWINGS FOR STRUCTURAL FOUNDATIONS, STRUCTURES, AND /OR TRENCHING, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTRACT WITH THE ENGINEER DIRECTLY AND THE COST SHALL BE INCLUDED IN THE BASE BID. 19. ALL SYSTEMS AND SERVICES ARE TO BE LEFT OPERATIONAL PRIOR TO THE END OF EACH WORKDAY. 20. CONTRACTOR TO COORDINATE RELOCATION OF FIRE ALARM SYSTEM WITH WAREHOUSE MANAGER. 21. THE CONTRACTOR SHALL REMOVE ALL RUBBLE AND DEBRIS FROM THE JOBSITE DAILY AND LEAVE THE BUILDING AND GROUNDS BROOM CLEAN UPON COMPLETION OF THE WORK. OPERATIONAL PHASING NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL CONSTRUCTION PHASING SO AS NOT TO IMPACT THE OWNER'S OPERATIONS. 2. REMOVE WALLS, BOLLARDS, PLUMBING, ELECTRICAL, ETC. AND CAP UTILITIES AS REQUIRED TO ACHIEVE THE OPERATIONAL PHASING. 3. PROVIDE TEMPORARY UTILITIES AS REQUIRED DURING PHASING. 4. WHEN THE WORK INCLUDES DEMOLITION OF OR TEMPORARILY COVERING OF THE EXISTING EXTERIOR SIGNAGE, THE CONTRACTOR SHALL PROVIDE A TEMPORARY "COSTCO WHOLESALE" SIGNAGE (OF SIZE COMPARABLE TO EXISTING SIGN) UNTIL PERMANENT SIGN IS INSTALLED. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. PROVIDE ILLUMINATION FOR THE TEMPORARY SIGN. CONFIRM LOCATIONS WITH THE OWNER. FLOOR AREA: EXISTING WAREHOUSE = ADDED SALES = TIRE CENTER = TOTAL = NUMBER OF STORIES: 1 AUTOMATIC FIRE SPRINKLER SYSTEM: FIRE ALARM SYSTEM: 176,967 SF 12,011 SF 4,674 SF 193,652 SF YES NO [X] [ ] [X] [ l WAREHOUSE: TOTAL OCCUPANTS - EXIST. WAREHOUSE: TOTAL OCCUPANTS - ADDED: TOTAL OCCUPANTS EGRESS WIDTH PER PERSON: 0.20 REQUIRED EGRESS WIDTH (IN INCHES): 1,260 EGRESS WIDTH PROVIDED (IN INCHES): (23) 48" DOORS AT 45" NET (4) 51" DOORS AT 48" NET (1) 40" DOORS AT 37" NET (1) 36" DOORS AT 33" NET TOTAL 5,899 400 6,299 = 1035 = 192 = 37 = 33 = 1297 TIRE INSTALLATION: TOTAL OCCUPANTS- TIRE INSTALLATION: 23 EGRESS WIDTH PER PERSON: 0.20 REQUIRED EGRESS WIDTH (IN INCHES): 6 EGRESS WIDTH PROVIDED (IN INCHES): (3) 36" DOORS AT 33" NET = 99 TOTAL = 99 RECEIVED SEP 12 2011 PERMIT CENTER COSMO WHOLESALE TUKWILA WA #06 400 COSTCO DRIVE TUKWILA, WA 98188 COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com 1110 112TH AVE. NE I SUITE 500 BELLEVUE, WA 1 98004 t 425.463.2000 I f 425.463.2002 MulvannyG2.com ISSUE FOR PERMIT RUSSELL H. HAZZARD, ARCHITECT 1 © MulvannyG2 Architecture: All rights reserved. No part of this document may be reproduced in any form or by any means without permission in writing from MulvannyG2 Architecture. DATE 08.17.11 09.13.11 DESCRIPTION Permit Release BUILDING DEPT. CORRECTIONS 93- 0440 -25 PM: KEVIN KOTAN DRAWN: bsd AUGUST 17, 2011 DEMOLITION PLAN A1.01 J I UKHUI_ WOMEN'S MEN'S RESTROOM RESTROOM EXP1REu MAY 022012 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 15 2011 City of Tukwila BUILDING DIVISION DEMOLITION KEY NOTES GENERAL NOTES BUILDING STATISTICS EGRESS SUMMARY 2 5 6 8 9 REMOVE REFRIGERATION PANELS. SEE OPERATION NOTES #3 & #4 DEMOLISH CMU WALL SEE OPERATION NOTES #1, #2, #3, #4, #6 AND #7. REMOVE STEEL RACKS AND ANCHOR BOLTS EMBEDDED IN CONCRETE FLOOR. SEE OPERATION NOTES #3 AND #4. - DEMOLISH STUD FRAME WALL. SEE OPERATION NOTES #1, #2, #3, #4, AND #6. DEMOLISH GYP BD. WALL ABOVE REFRIGERATION PANELS TO DECK ABOVE. REMOVE REFRIGERATION ROOF PANELS AND ASSOCIATED FIRE SPRINKLERS AND LIGHTING. SEE OPERATION NOTES #2, #3 AND #4. RAISED CONCRETE FLOOR AT PACKAGING ROOM TO BE CUT, GROUND DOWN AND RECEIVE SURFACE/SKIM CONCRETE COAT TO MATCH ADJACENT SLAB LEVEL. ALTERNATE TO REMOVE AND REPLACE CONCRETE IN THIS AREA. CONCRETE CURB AT GRIDLINE 'B' TO BE REMOVED. REMOVE DOOR HARDWARE AND AUTOMATED /ELECTRIC CLOSURE. LIGHTING TO BE LOCATED, TRACED TO SOURCE, DISCONNECTED AND REMOVED. RELOCATE AS NECESSARY EXISTING ELECTRICAL PANELS AND CIRCUITS. FIRE SPRINKLER SYSTEM TO BE ISOLATED DURING DEMOLITION OF REFRIGERATION ROOF PANELS, AND TO REMAIN IN PLACE AFTER REMOVAL. DEMOLITION & REMODEL CONSTRUCTION GENERAL NOTES THE BUILDING WILL BE OCCUPIED AND IN FULL USE BY THE OWNER DURING CONSTRUCTION. 1. CONSTRUCTION THAT MAY AFFECT THE PUBLIC SHALL BE DONE DURING OFF -HOURS 2. AREAS OF DEMOLITION SHALL INCLUDE, BUT ARE NOT LIMITED TO, ANY STRUCTURAL, PLUMBING, ELECTRICAL, MECHANICAL, FIRE SPRINKLER, ETC. ITEMS NECESSARY TO COMPLETE THE DEMOLITION WORK. THE CONTRACTOR IS TO REMOVE ALL WALLS, BOLLARDS, MISC. STEEL, PLUMBING, ELECTRICAL, RAISED CONCRETE SLAB, CURBS, REBARS, ETC. ASSOCIATED WITH DEMOLITION OF AREAS. SHOWN. 3. ALL REMOVED ITEMS NOT DESIGNATED FOR REUSE SHALL BE OFFERED IN GOOD CONDITION TO THE OWNER. DURING THE BIDDING PERIOD, COORDINATE AND VERIFY WITH THE OWNER AS TO WHICH ITEMS ARE TO BE SALVAGED. 4. DO NOT INTERRUPT ANY SERVICES (WATER, PLUMBING, FIRE SPRINKLER, ETC.) WITHOUT PRIOR WRITTEN APPROVAL OF THE OWNER. 5. MAINTAIN FIRE SPRINKLER AND FIRE ALARM SYSTEM IN OPERATING CONDITION AT ALL TIMES. NOTIFY THE OWNER AND COORDINATE AT LEAST 48 -HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING THE FIRE SPRINKLER OR FIRE ALARM SYSTEMS. PROVIDE FIRE -WATCH AS REQUIRED BY THE JURISDICTION. 6. PROVIDE AND MAINTAIN EGRESS PATHS THROUGHOUT CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EXIT SIGNS, LIGHTING, FIRE SPRINKLERS, ETC. OBTAIN FIRE MARSHAL APPROVAL PRIOR TO CLOSING ANY EGRESS OPENINGS AND /OR EGRESS PATHS DURING DEMOLITION /CONSTRUCTION. 7. THE CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND UTILITIES WITHIN PROXIMITY OF THE WORK AREA PRIOR TO EXCAVATION. AVOID CUTTING EXISTING CONDUIT OR PIPE EMBEDDED WITHIN FLOOR SLAB OR DIRECTLY BENEATH FLOOR SLAB, LASER SCAN OR SIMILAR METHOD SHALL BE CONDUCTED BY CONTRACTOR PRIOR TO CUTTING CONCRETE FLOOR. 8. PROVIDE TEMPORARY DUST PARTITIONS AS REQUIRED TO PREVENT DUST AND DEBRIS FROM SETTLING ON ADJACENT AREAS NOT UNDER CONSTRUCTION. REVIEW WITH AND OBTAIN OWNER'S APPROVAL FOR LOCATIONS. 9. THEiCONTRACTOR IS RESPONSIBLE FOR REPAIRING OR REPLACING ITEMS DAMAGED DURING DEMOLITION AND CONSTRUCTION. 10. WHEN CUTTING AND PATCHING, THE CONTRACTOR SHALL USE METHODS LEAST LIKELY TO DAMAGE ELEMENTS RETAINED OR ADJOINING SURFACES. CUT HOLES AND SLOTS AS SMALL AS PRACTICAL/POSSIBLE, NEATLY TO SIZE REQUIRED AND WITH MINIMUM DISTURBANCES OF ADJACENT MATERIALS. 11. WHERE EXISTING CONSTRUCTION IS REMOVED, CUT OR OTHERWISE DISTURBED, PATCH TO MATCH THE EXISTING ADJACENT SURFACES. SEAMS TO BE AS INVISIBLE AS PRACTICAL. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, ETC. 12. WHERE NEW WORK ABUTS OR ALIGNS WITH EXISTING, PERFORM A SMOOTH AND EVEN TRANSITION. PATCHED WORK TO MATCH EXISTING ADJACENT WORK IN TEXTURE AND APPEARANCE. 13. REMOVE AND REPLACE AREAS, SURFACES OR ITEMS THAT CANNOT BE SATISFACTORILY PATCHED. 14. AS A MINIMUM, THE LEVEL OF WORKMANSHIP SHOULD MATCH THE GENERAL LEVEL OF EXISTING WORKMANSHIP. 15. WHERE REQUIRED, TRIM EXISTING WOOD DOORS AS NECESSARY TO CLEAR FLOORING. SEAL CUT EDGES. 16. UNLESS SHOWN ON THE DRAWINGS OTHERWISE, DO NOT SUPPORT OR SUSPEND ITEMS, EQUIPMENT, HANGERS, ETC. FROM EXISTING STRUCTURAL MEMBERS (BEAMS, TRUSSES, JOIST, ETC.) WITHOUT WRITTEN APPROVAL OF A LICENSED STRUCTURAL ENGINEER. 17. DO NOT CUT OR DRILL ANY STRUCTURAL MEMBER (PARTICULARLY ROOF JOIST) WITHOUT WRITTEN APPROVAL OF A LICENSED STRUCTURAL ENGINEER. 18. SHORING OF STRUCTURAL. FOUNDATIONS, STRUCTURES, AND /OR TRENCHING REQUIRED TO COMPLETE THE WORK DESCRIBED IN THE DOCUMENTS IS CONSIDERED A MEANS, METHOD OR TECHNIQUE AND IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. IF A REGULATORY AGENCY REQUIRES A LICENSED ENGINEER TO SUPERVISE, APPROVE, AND /OR PROVIDE DRAWINGS FOR STRUCTURAL FOUNDATIONS, STRUCTURES, AND /OR TRENCHING, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONTRACT WITH THE ENGINEER DIRECTLY AND THE COST SHALL BE INCLUDED IN THE BASE BID. 19. ALL SYSTEMS AND SERVICES ARE TO BE LEFT OPERATIONAL PRIOR TO THE END OF EACH WORKDAY. 20. CONTRACTOR TO COORDINATE RELOCATION OF FIRE ALARM SYSTEM WITH WAREHOUSE MANAGER. 21. THE CONTRACTOR SHALL REMOVE ALL RUBBLE AND DEBRIS FROM THE JOBSITE DAILY AND LEAVE THE BUILDING AND GROUNDS BROOM CLEAN UPON COMPLETION OF THE WORK. OPERATIONAL PHASING NOTES 1. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL CONSTRUCTION PHASING SO AS NOT TO IMPACT THE OWNER'S OPERATIONS. 2. REMOVE WALLS, BOLLARDS, PLUMBING, ELECTRICAL, ETC. AND CAP UTILITIES AS REQUIRED TO ACHIEVE THE OPERATIONAL PHASING. 3. PROVIDE TEMPORARY UTILITIES AS REQUIRED DURING PHASING. 4. WHEN THE WORK INCLUDES DEMOLITION OF OR TEMPORARILY COVERING OF THE EXISTING EXTERIOR SIGNAGE, THE CONTRACTOR SHALL PROVIDE A TEMPORARY "COSTCO WHOLESALE" SIGNAGE (OF SIZE COMPARABLE TO EXISTING SIGN) UNTIL PERMANENT SIGN IS INSTALLED. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS. PROVIDE ILLUMINATION FOR THE TEMPORARY SIGN. CONFIRM LOCATIONS WITH THE OWNER. FLOOR AREA: EXISTING WAREHOUSE = ADDED SALES = TIRE CENTER = TOTAL = NUMBER OF STORIES: 1 AUTOMATIC FIRE SPRINKLER SYSTEM: FIRE ALARM SYSTEM: 176,967 SF 12,011 SF 4,674 SF 193,652 SF YES NO [X] [ ] [X] [ l WAREHOUSE: TOTAL OCCUPANTS - EXIST. WAREHOUSE: TOTAL OCCUPANTS - ADDED: TOTAL OCCUPANTS EGRESS WIDTH PER PERSON: 0.20 REQUIRED EGRESS WIDTH (IN INCHES): 1,260 EGRESS WIDTH PROVIDED (IN INCHES): (23) 48" DOORS AT 45" NET (4) 51" DOORS AT 48" NET (1) 40" DOORS AT 37" NET (1) 36" DOORS AT 33" NET TOTAL 5,899 400 6,299 = 1035 = 192 = 37 = 33 = 1297 TIRE INSTALLATION: TOTAL OCCUPANTS- TIRE INSTALLATION: 23 EGRESS WIDTH PER PERSON: 0.20 REQUIRED EGRESS WIDTH (IN INCHES): 6 EGRESS WIDTH PROVIDED (IN INCHES): (3) 36" DOORS AT 33" NET = 99 TOTAL = 99 RECEIVED SEP 12 2011 PERMIT CENTER COSMO WHOLESALE TUKWILA WA #06 400 COSTCO DRIVE TUKWILA, WA 98188 COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com 1110 112TH AVE. NE I SUITE 500 BELLEVUE, WA 1 98004 t 425.463.2000 I f 425.463.2002 MulvannyG2.com ISSUE FOR PERMIT RUSSELL H. HAZZARD, ARCHITECT 1 © MulvannyG2 Architecture: All rights reserved. No part of this document may be reproduced in any form or by any means without permission in writing from MulvannyG2 Architecture. DATE 08.17.11 09.13.11 DESCRIPTION Permit Release BUILDING DEPT. CORRECTIONS 93- 0440 -25 PM: KEVIN KOTAN DRAWN: bsd AUGUST 17, 2011 DEMOLITION PLAN A1.01 i i EXISTING CONCRETE BLOCK WALL EXIST. TRANSFORMER TRANSFORMER FIRE PROTECTION STAND PIPES FIRE HYDRANT GAS VAL L EXISTING MEZZANINE ABOVE TO REMAIN 38' -1 b" EXISTING PRODUCE COOLER =15' STEED OFFICE USDA OFFICE 115' STEELi SUPPLY AREA CONTROL;/ HE/LTH I BREAK ROOT COMPACTOR TELEPHONE CLOSET BALER /COMPACTOR ROOM WATER METER WATER VALVE BATTERY CHARGER MAINTENANCE ELECT. J JANITOR 1ST. TRANS. PARTIAL FLOOR PLAN 1 SCALE: 1/16 " =1' -0" GYP. BD. WALL TO DECK ABOVE TYP. ■r MINI I�r1 IlAlI1 I I- - -- Ir I �s� —IAI -- - •1-- N =I1r1 1 Mal 111111110—r —i —r IIIlI1�17 1 Ilrtl■rtal�Iil1■tl11 it111ul —a1111lx 1101illl—Ir111111llw— ■1111111 N ti I Irtf1.1111 1N -11111 i- -1111 111111111M1111011111111111•1111 lr CONCRETE MIX NOTE: TYPE III HIGH EARLY STRENGTH CONCRETE SHALL BE USED AT SLAB REPAIR EXIST. CONC. SLAB 0 FINSIH FLR O' -0" INTERIOR ELEVATION 2 SCALE: NTS SAW CUT & REMOVE SLAB AS REQ'D. ADD #4 © 18" 0/C TYP. @ -C (LAP 24" MIN.) NEW CONC. SLAB FY = 4000 PSI MIN. • 4 U- > III— III -III- 111=111=111= 11111111 COMPACTED SUBGRADE 5" TYP. 0c o. C, 0 0 0 000 0, III•• 11 =1y I= SLAB REPAIR (ALT #4 @18 "0 /C@- C (LAP 24 "MIN.) STAGGER E.S. OF TRENCH. EPDXY w/ HILTI HY -150 ADHESIVE. EMBED 5" MIN. w/ SPECIAL INSPECTION. SCALE: 3/4" = 1' -0" ENI 0 EXISTING PLYWOOD EXISTING 2x 2x4 DF © 24" O.C. w/ SIMPSON HU HANGERS EA. END 14GA. n DEFLECTION TRACK w/ (2) FLANGES. (2) 10d NAILS AT EACH 2x 5/8" GYP AT EA. SIDE. DO NOT ATTACH TO DEFLECTION TRACK 6005162 -43 (C6x1 5/8"x18GA) AT 24" O.C. (MAX HT. = 25' -0 ") 18GA. BOTTOM TRACK w/ 0.177"0x11/2 "LOW VELOCITY PINS AT 18" O.C. EM EXISTING CONC. SLAB DEMISING WALL DETAIL SCALE: 3/4" =11-0" +1- 26' -0" V.I.F. ( 6, DEFLECTION TRACK AT BOTTOM OF JOISTS COPTION #1 5 SCALE: 3/4" = 1' -0" EXISTING 8" CMU WALL VERIFY SOLID GROUT CELLS AT BOLT LOCATIONS 2x H.F.#2 P.T. w/ 1/2" 0 THREADED RODS AT 48" O.C. EMBED 4 1/2" w HILTI HY -150 MAX (ESR -1967) AND SPECIAL INSP. REFRIGERATION PANEL FLUSH WITH CMU ON WAREHOUSE SIDE COMPUI A .C'. SEP 5 2011 City of Tukwila BUILDING DIVISION 'p7A OPTION #2 EXISTING 8" CMU WALL VERIFY SOLID GROUT CELLS AT PIN LOCATIONS 18GA. TRACKS w/ 0.177" 0 LOW VELOCITY DRIVE PINS AT 24" O.C. EMBED. 1 1/2" 6" x 1 5/8" X 18GA STUDS 24" O.C. GYP SHEATHING EA. SIDE SCALE: 3/4" = 1' -0" IEXPIREP MAY 0 22.012 KEY NOTES e 1 2 4 5 18 ga. 6" METAL STUDS @ 24" OC w/ 5 /8" GYP. BD. EACH SIDE AS SHOWN TO DECK =OVE /DEFLECTION TRACK. INF!LL DOOR OPENINGS AS SHOWN WITH EXISTING SALVAGED REFRIGERATION PANELS OR GWB @ EACH SIDE. SEE OPTION 1 AND 2 BELOW. CONCRETE FLOOR TO BE PATCHED TO MATCH EXISTING CONCRETE SLAB. ALTERNATE TO PROVIDE NEW CONCRETE SLAB IN THIS AREA. PATCH CONCRETE SLAB AS REQUIRED WHERE ANCHOR BOLTS WERE REMOVED. 3 5 / 8" METAL STUDS AT 24" OC w/ 5 /8" GYP. BD. EACH SIDE TO BOTTOM OF EXISTING MEZZANINE. RECEIVED SEP 12 2011 PERMIT CENTER COST= =WHOLESALE TUKWILA, WA #06 400 COSTCO DRIVE TUKWILA, WA 98188 COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com 1110 112TH AVE. NE I SUITE 500 BELLEVUE, WA 1 98004 t 425.463.2000 I f 425.463.2002 MulvannyG2.com ISSUE FOR PERMIT RUSSELL H. HAZZARD, ARCHITECT 1 RUSS STATE t © MulvannyG2 Architecture: All rights reserved. No part of this document may be reproduced in any form or by any means without permission in writing from MulvannyG2 Architecture. ERED ITECT H. HAZZARD WASHINGTON DATE 08.17.11 09.13.11 DESCRIPTION Permit Release BUILDING DEPT. CORRECTIONS 93- 0440 -25 PM: KEVIN KOTAN DRAWN: bsd AUGUST 17, 2011 FLOOR PLAN A1.02 WOMEN'S MEN'S RESTROOM RESTROOM GYP. BD. WALL TO DECK ABOVE TYP. ■r MINI I�r1 IlAlI1 I I- - -- Ir I �s� —IAI -- - •1-- N =I1r1 1 Mal 111111110—r —i —r IIIlI1�17 1 Ilrtl■rtal�Iil1■tl11 it111ul —a1111lx 1101illl—Ir111111llw— ■1111111 N ti I Irtf1.1111 1N -11111 i- -1111 111111111M1111011111111111•1111 lr CONCRETE MIX NOTE: TYPE III HIGH EARLY STRENGTH CONCRETE SHALL BE USED AT SLAB REPAIR EXIST. CONC. SLAB 0 FINSIH FLR O' -0" INTERIOR ELEVATION 2 SCALE: NTS SAW CUT & REMOVE SLAB AS REQ'D. ADD #4 © 18" 0/C TYP. @ -C (LAP 24" MIN.) NEW CONC. SLAB FY = 4000 PSI MIN. • 4 U- > III— III -III- 111=111=111= 11111111 COMPACTED SUBGRADE 5" TYP. 0c o. C, 0 0 0 000 0, III•• 11 =1y I= SLAB REPAIR (ALT #4 @18 "0 /C@- C (LAP 24 "MIN.) STAGGER E.S. OF TRENCH. EPDXY w/ HILTI HY -150 ADHESIVE. EMBED 5" MIN. w/ SPECIAL INSPECTION. SCALE: 3/4" = 1' -0" ENI 0 EXISTING PLYWOOD EXISTING 2x 2x4 DF © 24" O.C. w/ SIMPSON HU HANGERS EA. END 14GA. n DEFLECTION TRACK w/ (2) FLANGES. (2) 10d NAILS AT EACH 2x 5/8" GYP AT EA. SIDE. DO NOT ATTACH TO DEFLECTION TRACK 6005162 -43 (C6x1 5/8"x18GA) AT 24" O.C. (MAX HT. = 25' -0 ") 18GA. BOTTOM TRACK w/ 0.177"0x11/2 "LOW VELOCITY PINS AT 18" O.C. EM EXISTING CONC. SLAB DEMISING WALL DETAIL SCALE: 3/4" =11-0" +1- 26' -0" V.I.F. ( 6, DEFLECTION TRACK AT BOTTOM OF JOISTS COPTION #1 5 SCALE: 3/4" = 1' -0" EXISTING 8" CMU WALL VERIFY SOLID GROUT CELLS AT BOLT LOCATIONS 2x H.F.#2 P.T. w/ 1/2" 0 THREADED RODS AT 48" O.C. EMBED 4 1/2" w HILTI HY -150 MAX (ESR -1967) AND SPECIAL INSP. REFRIGERATION PANEL FLUSH WITH CMU ON WAREHOUSE SIDE COMPUI A .C'. SEP 5 2011 City of Tukwila BUILDING DIVISION 'p7A OPTION #2 EXISTING 8" CMU WALL VERIFY SOLID GROUT CELLS AT PIN LOCATIONS 18GA. TRACKS w/ 0.177" 0 LOW VELOCITY DRIVE PINS AT 24" O.C. EMBED. 1 1/2" 6" x 1 5/8" X 18GA STUDS 24" O.C. GYP SHEATHING EA. SIDE SCALE: 3/4" = 1' -0" IEXPIREP MAY 0 22.012 KEY NOTES e 1 2 4 5 18 ga. 6" METAL STUDS @ 24" OC w/ 5 /8" GYP. BD. EACH SIDE AS SHOWN TO DECK =OVE /DEFLECTION TRACK. INF!LL DOOR OPENINGS AS SHOWN WITH EXISTING SALVAGED REFRIGERATION PANELS OR GWB @ EACH SIDE. SEE OPTION 1 AND 2 BELOW. CONCRETE FLOOR TO BE PATCHED TO MATCH EXISTING CONCRETE SLAB. ALTERNATE TO PROVIDE NEW CONCRETE SLAB IN THIS AREA. PATCH CONCRETE SLAB AS REQUIRED WHERE ANCHOR BOLTS WERE REMOVED. 3 5 / 8" METAL STUDS AT 24" OC w/ 5 /8" GYP. BD. EACH SIDE TO BOTTOM OF EXISTING MEZZANINE. RECEIVED SEP 12 2011 PERMIT CENTER COST= =WHOLESALE TUKWILA, WA #06 400 COSTCO DRIVE TUKWILA, WA 98188 COSTCO WHOLESALE CORPORATION 999 LAKE DRIVE ISSAQUAH, WA 98027 T: 425.313.8100 www.costco.com 1110 112TH AVE. NE I SUITE 500 BELLEVUE, WA 1 98004 t 425.463.2000 I f 425.463.2002 MulvannyG2.com ISSUE FOR PERMIT RUSSELL H. HAZZARD, ARCHITECT 1 RUSS STATE t © MulvannyG2 Architecture: All rights reserved. No part of this document may be reproduced in any form or by any means without permission in writing from MulvannyG2 Architecture. ERED ITECT H. HAZZARD WASHINGTON DATE 08.17.11 09.13.11 DESCRIPTION Permit Release BUILDING DEPT. CORRECTIONS 93- 0440 -25 PM: KEVIN KOTAN DRAWN: bsd AUGUST 17, 2011 FLOOR PLAN A1.02