HomeMy WebLinkAboutPermit D11-288 - HOOPER HOLMES - COUNTERSHOOPER HOLMES 15445 53 AV S Di 1-288 City atTukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1157200035 Address: 15445 53 AV S TUKW Suite No: Project Name: HOOPER HOLMES DEVELOPMENT PERMIT Permit Number: D11 -288 Issue Date: 09/27/2011 Permit Expires On: 03/25/2012 Owner: Name: QESTAR THREE L L C Address: PO BOX 24060 , FEDERAL WAY WA 98093 Contact Person: Name: GREG DIENER Address: 15445 53 AV S, SUITE 100 , TUKWILA WA 98188 Contractor: Name: ADVANCE BLDRS /TECHNOLOGIES LLC Address: 6805 STEWART AVE E , PUYALLUP WA 98371 Contractor License No: ADVAN * *954P1 Phone: 206 - 431 -7970 Phone: 253 - 268 -0052 Expiration Date: 11/02/2011 DESCRIPTION OF WORK: TENANT IMPROVEMENT: 2 NEW COUNTERS Value of Construction: $10,000.00 Fees Collected: $464.52 Type of Fire Protection: AFA International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0008 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -288 Printed: 09 -27 -2011 • • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this pe construction or the perfo - c - to this permit. �/ Signature: i I/ I l N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: (f4*\ d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. oes not pre ork. Print Name: to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this development permit and agree to the conditions attached c- Date: \ 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11-288 Printed: 09 -27 -2011 7: All construction shall be done in confornee with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75 or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain automatic fire detector coverage per N.F.P.A. 72. Addition/relocation of walls, closets or partitions may require relocating and/or adding automatic fire detectors. 26: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) doc: IBC -7/10 D11 -288 Printed: 09 -27 -2011 27: Maintain fire alarm system audible /visu tification. Addition/relocation of walls or pa ns may require relocation and/or addition of audible /visual cation devices. (City Ordinance #2051) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 30: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -288 Printed: 09 -27 -2011 • CITY OF W JKWILA Community Development Department Public Works'Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.ciov • Q Building Permit No. • L l -)-8 8 Mechanical Permit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 15yy5 5r',4 ✓c S Tenant Name: J/coDo r' 140 /nom Property Owners Name: G e1.c- Mailing Address: f . 0. k7ox 2 'f04,0 King Co Assessor's Tax No.: //i 20003 Suite Number: 110 Floor: New Tenant: Yes ❑ ..No qty/ l4- l./A 110/3 C state Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: ld Mailing Address: E -Mail Address: erl.c-,r— Day Telephone: 7-0C /6ggS 53tA,4,c 3 &A./4 IGO Se- 44/1. 4/31 - 9f7o l./1} 171 IT @rc2.6. pn0.co City Fax Number: (ZOC) State Zip 3g-_ lbgf GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Akalnc.- Bu.IC rs awl ;anv�estc3i -a-S (.A- Mailing Address: (� g05 5 kewa. -`4 Aim- '_ f iii., W ll Cf 7/ State Zip Contact Person: T. T, In (1 r" Day Telephone: .25.3 218 egg) E -Mail Address: i4uanct. bc..adLvs ekd 63 1, s @c c.,si-.ke Fax Number: d.J3 t/tl5 S7 % ontractor Registration Number: ADUa41U'g"'k ?S4PL Expiration Date: l ii /S .l Z ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: E -Mail Address: State Zip ENGINEER OF RECORD - All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H: 1Applications\Forms- Applications On Iine\2010 Appliiations7 -2010 - Permit Application.doc Revised: 7 -2010 bh ' I∎A 'vim. 4SS City State Zip Day Telephone: c> - 4-57,1- -1 1 Fax Number:. « 11 `°' , Page 1 of 6 BUILDING PERM TT INFORMATIO1r 206 -431 -3670 Valuation of Project (contractor's bid price): $ tae a IV Existing Building Valuation: $ 1,7 ") Scope of Work (please provide detailed information): ��' Will there be new rack storage? ❑ Yes cg. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 0m. Floor area of principal dwelling? Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers pi Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No 1f `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications \Forms - Applications On line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la` Floor Wien \I3k. v 4:5 115 rd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): 0m. Floor area of principal dwelling? Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers pi Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No 1f `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 "paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \Applications \Forms - Applications On line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE AWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT Signature: Print Name: H�, ENT: -IC lP4 k t* '5 Mailing Address: Date: tZ3\Ztdt Day Telephone: 2Z6 City State Zip Date Application Accepted: Q,�? Date Application Expires: .11 1 X. Staff Initials: H:\Applications\Forms- Applications On Line\20I0 Applications\ 7-2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 • • City of Tukwila tiDepartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 1157200035 Address: 15445 53 AV S TUKW Suite No: Applicant: HOOPER HOLMES RECEIPT Permit Number: D11 -288 Status: PENDING Applied Date: 08/23/2011 Issue Date: Receipt No.: R11 -01841 Payment Amount: $464.52 Initials: WER Payment Date: 08/23/2011 02:50 PM User ID: 1655 Balance: $0.00 Payee: PACIFIC ENGINEERING DESIGN TRANSACTION LIST: Type Method Descriptio Amount Payment Check 90772 464.52 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $464.52 278.80 181.22 4.50 doc: Receiot -06 Printed: 08 -23 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,C)// 69® PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: ,/boo i'-‘ e //on?o S Type of Inspection: /A/, Y L Address: /''`VY5'5'34Us Date Called: Special Instructions: Date Wanted:. a.m. Requester: Phone No: 90 6- -..r/- 7`i7b ® Approved per applicable codes. a Corrections required prior to approval. COMMENTS: 0 Sf f AeAlrtogel (} 0,7,,,/ 5 - /1"., /,!/, /% ►.,�) I" eta-vi ,)., C - /;),, p,/ „!' Pe7,-,,, ; 4 a" i# I- /,---;,1,,4 / y I4spector: Date: I,,,,,t*) / j q- g0— /i PECTION FEE REQU RED. Prior to next inspection. fee must be at 6300 Southcenter Blv .. Suite 100. Call to schedule reinspection. ■ ...••"••l .scam - -s. . -, -- ...o-.wq'q,;r —; rte- "- - - - --•. -- _�� a;r _ -p• .. .. .., .�'^f: nom•: •� :-r..?s^�riaGysi INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 6a 8g PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project ' c PAC &.N )Neer '1'411 Type�of Inspection: Hood & Duct: Address: Suite #: / S-N Y c �1 s 3 S Contact Person: Special Instructions: e Phone No.: (4pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 4�^ 5.--,9-... Date: 947-#//( Hrs.: t $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • Gity of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 14, 2011 Greg Diener 15445 53 Av S, Suite 100 Seattle, WA 98188 RE: Correction Letter #1 Development Permit Application Number D11 -288 Hooper Holmes —15445 53 Av S Dear Mr. Diener, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Bill Rambo Permit Technician encl File No. D11 -288 W:\Permit Center \Correction Letters \2011\D11 -288 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: September 7, 2011 Project Name: Hooper Holmes Permit #: D11 -288 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The plan indicates one space divided into two spaces. This alters the means of egress for each tenant. Please provide an egress plan that clearly identifies all common paths of egress for these tenants to the exit discharge. Emergency illumination shall be provided along the common paths of egress and shall have at least an average 1 foot - candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways and any related discharge components that lead to a public way. Show any revise directional exit signs. (IBC Section 1006) 2. For clarification on the occupant count, provide an occupant count with the separate square footage of the two separate tenant spaces. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. • • City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: 12 11/ - IA Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Summary of Revision: Phone Number: 7...4:6) " "43 .- 11 z1511 tos-or54. txcl )4,0■64.vdoPts-5. roirwu AUG 3 01011 tjeimacEivrei Sheet Number(s): 1 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Cent; by: xEntered in Permits Plus on D '7V ■ HAAppiicatinns\Fmms- Applimtmns On Line\2010 ApplicationsV2 -2010 - Revision Sulminal.doc Revised: May 2011 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director August 26, 2011 Greg Diener 15445 53 Av S, Ste 100 Seattle, WA 98188 RE: Incomplete Letter #1 Development Permit Application D11 -288 Hooper Holmes —15445 53 Av S Dear Mr. Diener, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 23, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, fer Marshall t Technician res File: i 11 -288 W:\Permit Center\Incomplete Letters\2011\D11 -288 Incomplete Ltr #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: August 25, 2011 Project Name: Hooper Holmes Permit #: D11 -288 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Code references are out of date. Please update code references to reference 2009 building codes and energy codes. Plan details and designs shall meet current codes. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. *EMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -288 DATE: 09/16/11 PROJECT NAME: HOOPER HOLMES SITE ADDRESS: 15445 53 AV S Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # after Permit Issued DEP TMENTSm Z II B I ng Ivision 11-111 Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete L)4 Incomplete DUE DATE: 09/20/11 Not Applicable Comments: Permit Center Use'Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required ri REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/18/11 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 HERMIT COORS COPlfj PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -288 PROJECT NAME: HOOPER HOLMES DATE: 08/30/11 SITE ADDRESS: 15445 53 AV S Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPAR MEN S: Bui ding Division Public Works Fire Prevention ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1X,1 Incomplete n DUE DATE: 09/01/11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route yi Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09 /29/11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg tik Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 op • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: 011 -288 DATE: 08 -23 -11 PROJECT NAME: HOOPER HOLMES SITE ADDRESS: 15445 53 AV S X Original Plan Submittal Response to Correction Letter # Revision # After Permit Issued Response to Incomplete Letter # DEPARTMENTS: m 0 ui ding lIision �• Puc Works 90,\ Auk q-&11 /� o� 2S• 1� Fire Prevention p Planing' Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete Comments: DUE DATE: 08-25-11 Not Applicable n Permit Center Use Only pp�� ^ f 21 , INCOMPLETE LETTER MAILED: VDl U Departments determined incomplete: Bldg] Fire ❑ Ping ❑ PW ❑ Staff Initials:„ dV LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route ❑ Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-22-11 Approved ❑ Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 605/20/1 Plan Check/Permit Number: O I I - z_Fg- ❑ Response to Incomplete Letter # jResponse to Correction Letter # 4. ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 14 eJ— 6✓plv>i�S Project Address: J5 ) y5 53'`A AVe- Contact Person: V 0' Phone Number: Zo( X131- 170 Summary of Revision: Aced toc OCec,pa v2 -1` cK ar r4 -A- -fib Cow VSh.. -I-. re-6s rode ,tea 6h - 0.03. L►a -��octY,s a/cd , a t, r n v13e&C seid(eGQ �Siol✓t6. REeevee CITY OF ruicwitA SEP152011 HERMIT CENTER Sheet Number(s): l -O ac.J "Cloud" or highlight all areas o!revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: 1 -2009 Contractors or Tradespeople Pr ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ADVANCE BLDRS /TECHNOLOGIES LLC UBI No. 602548493 Phone 2532680052 Status Active Address 6805 Stewart Ave E License No. ADVAN "954P1 Suite /Apt. License Type Construction Contractor City Puyallup Effective Date 11/2/2005 State WA Expiration Date 11/2/2011 Zip 98371 Suspend Date County Pierce Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company ADVANCEBUILDERSANDTECHNOLOGIES Business Owner Information Name Role Effective Date Expiration Date FULLER, JEREMIAH Partner /Member 10/22/2005 Amount MACKEY, CLIFF Partner /Member 10/22/2005 B1S000049803 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SG0702 10/18/2005 Until Cancelled $12,000.00 10/27/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 DEVELOPERS SURETY & INDEM CO B1S000049803 10/18/2010 10/18/2011 $1,000,000.00 10/01/2010 4 DEVELOPERS SURETY & INDEM CO BIS0000049802 10/18/2009 10/18/2010 $1,000,000.00 09/30/2009 3 DEVELOPERS SURETY & INDEM CO bis0000049801 10/18/2008 10/18/2009 $1,000,000.00 10/06/2008 2 CBIC C11SG0702 10/18/2006 10/18/2008 $1,000,000.00 09/27/2007 1 CBIC C11SG0702 10/18/2005 10/18/2007 $300,000.00 09/19/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 09/27/2011 REVISION': UPDATED REFERENCE TO 2009 IBC AND WSEC 2011- 08 -30; UPDATED OCCUPANCY CALCULATIONS 2011 -09 -12 4 SEC 23, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M. CITY OF TUKWILA _S 146th St :- —( . s- 48th-St---- MapPofnt .St S- 156th'St 5 VISITO ST 158th •fit S 160th St1 ;:-162nd St -•. ±164th St-- SeaTac oulhcente� _ti16 HOOPER HOLMES OFFICE BOUNDARY / R.O.W. LINE CENTERLINE -�D- — — CATCHBASIN (TYPE 1). W/ ST LINE 4-•44 FIRE HYDRANT ASSEMBLY z WATER VALVE DOMESTIC WATER METER. 6" BUILDING SEWER CLEANOUT LEGAL DESCRIPTION LOT 2, CITY OF TUKWILA SHORT PLAT NUMBER 78- 29 -SS, ACCCORDING TO THE SHORT PLAT THEREOF RECORDED OCTOBER 17, 1979 UNDER RECORDING NO 7910170915, RECORDS OF KING COUNTY, WASHINGTON. TOGETHER WITH A NON - EXCLUSIVE EASEMENT FOR INGRESS AND EGRESS AS DELINEATED ON CITY OF TUKWILA SHORT PLAT NUMBER 78- 29 -55, RECORDED UNDER . RECORDING NO 7910170915, RECORDS OF KING COUNTY, WASHINGTON. SHEET INDEX COI COVER SHEET /COMPOSITE UTILITIES PLAN - -1 CO2 FLOOR PLAN, SCHEDULES CO3 REFLECTED CEILING AND LIGHTING PLAN C04 DETAILS C05 EXISTING CONOI T IONS EXISTING BUILDING INFORMATION PARKING STALLS: 51 PARKING STALLS + 2 H/C STALLS 53 TOTAL. STALLS 6 STALLS 7 STALLS 1 STALL LANDLORD BUILDING AREA OCC. TYPE: OWNER STROUT FINANCIAL OFFICE PACIFIC ENGINEERING DESIGN, LLC 15445 53RD AVE S SEATTLE, WA 98188 PHONE (206) 4.31-7970 FAX: (206) .388-1648 SITE INFORMATION PARCEL NO. SITE ADDRESS 8,700 SQ. FT. B (OFFICE) UNCHANGED QESTAR THREE LLC P.O. BOX 24060 FEDERAL WAY, WA. 98093 -1060 1157200035 15445 53RD AVE. SOUTH TUKWILA, WA. 98188 FILE COPY Permit No., DI Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of ny : dopted code or ordinance. Receipt of s�pproved rift and conditions Is acknowledged: BY SCALE: 1' -20' SEPARATE PERMIT REQUIRED FOR Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION CODE: OCCUPANCY TYPE: OVERALL AREA: HOOPER HOLMES OCCUPANCY: STROUT FINANCIAL OCCUPANCY PACIFIC ENGINEERING DESIGN OCCUPANCY 5,494 S.F. / 100 = 55 a REV INED FOR CODE COMPLIANCE APPROV!ia SEP 2 6 2011 2009 IBC, 2009 WSEC W/ AMENDMENTS B (OFFICE) 8,700 S.F. 1,934 S.F. / 100 = 19 1,272 S.F. / 100 = 13 PROJECT NO.: 05050 ENERGY. CODE RECAP DRAWN BY: CJB NO NEW CEILING PROPOSED ALL OTHER CEILING AREAS EXISTING. RELOCATE FIXTURES AS REQUIRED TO AVOID NEW PARTITIONS. BUILDING SHELL ALL SHELL INSULATION IS EXISTING ISSUE DATE: SHEET REV.( 09-12-27) PLANNING APPROVED No changes can be made. to these plans without approval from the Planning Division of DOD cP11iwd\ Dads: (� 1 PROJECT DESCRIPTION PROJECT VALUATION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. AREA OF WORK: $10,000 1,934 SF RECONFIGURE EXISTING OFFICE SPACE BY ADDING NEW WALLS AND REMOVING OLD WALLS. ACCESSIBILITY COMPLIANCE 1. BUILDING SHELL AND PARKING AREAS ARE EXISTING. ALL TENANT SPACES ARE ACCESSIBLE BY AN ACCESSIBLE ROUTE FROM THE PARKING AREAS. 2. ALL DOOR HARDWARE TO BE LEVER TYPE. 3. HANDICAP TOILETS CONFIGURED PER WAC . 51 -10. COVER SHEET/ COMPOSITE UTILITIES PLAN; GRADING AND DRAINAGE PLAN 05055CV01 —001. DWG SHEET 1 OF 5 REVISIONS: RANGE 4 EAST, W.M. SYMBOL LEGEND. OFFICE REMOVE-:'' 000 OCC SENSOR. F.E. EX. DATA OUTLET EX. TELEPHONE OUTLET �- EXISTING. WALLS TO BE REMOVED ' EXISTING WALLS TO STAY NEW WALLS I 1 EXISTING RELITE EX: LIGHT SWITCH EMERGENCY LIGHTING FIXTURE CEILING MOUNTED EXIT FIXTURE WITH DIRECTIONAL 'ARROWS AS INDICATED WALL MOUNTED EXIT FIXTURE FIRE ALARM MANUAL PULL STATION OCCUPANCY SENSOR WALL MOUNTED FIRE EXTINGUISHER FIRE ENUNCIATOR/STROBE ROOM RNISH SCHEDULE FLOOR CARPET BASE 4' RUBBER OR VINYL BASEBOARD WALLS - PAINT OVER G.W.B. CLG. 5U5P. ACOUS. CEILING TILES FLOOR - SHEET VINYL/VCT BASE 6" RUBBER OR VINYL BASEBOARD WALLS - ENAMEL OVER G.W.B. CLG. - SUSP. ACOUS. CEILING TILES 0°8 (A 013 WO 0 00 > IN lir 2 (0 ij L r 00 W U �-�W M ~Z i'<—tOtok@coo oow to coaa..�ua., a.. bA � 1.4 471 u oeN eirci bo 4.1�� w A TORAG P.n,Ar�e� .,.;,.2.J.,,, ®�.s„o�,,,;,Yirk/% REMOVE WALL REMOVE. WdLL EXI 71 G ABINETS / /SH L REMdVFUPPER' CABINETS RELAMN,A TE/COUN.TERI ADD OdORS.TO CABINE S SE ,DETAI,L/TjHIS�SHEET. NEW LAMINATE ALL SIDES NEW WALLS 3' 10" 23.5" 23.5" COUNTER TOP 2' 6" 8.5 LF NEW FULL HEIGHT WALL NEW FRONT DESK COUNTER 8'Lx2.5'Wx36 "H SHELVES ',UNDERNEATH.` SEE DETAIL: THIS SHEET. U Cb I modal" mail ' wrzeigrarci i 1-nlmo mmerio1 _t• . U. EX. STONE T1LE ENTRY r- EX. WALL r EX. DOOR REMOVE DOOR EX T1LE FLOOR NEW 2 SHELF CABINET WITH DOORS WEST ELEVATION 8DE FRONT DESK COUNTER SCALE 1 " =2' LAMINATE ALL SURFACES OF NEW CABINET OCC,. SENSOR fn 19E EX.-' WALL. ALL STAINED CEILING ' TILES TO BE REPLACED. TILES: ON HAND. REKEY BOTH ENTRY. DOORS BY OTHERS. REPROGRAM SECURITY SYSTEM FOR NEW SPACE BY STANLEY SECURITY SYSTEMS. EX. KEYPAD TO REMAIN LL 0 0 0 i N 0`y N r .. 0 IL 403 ro W (0 }N cc X3N _1" .. i--mwz mwOw= OIL IL IL GRAPHIC SCALE: 1/4' -1' -0" NEW LAMINATED t CABINET DOORS TO BE INSTALLED ON ALL THREE SECTIONS 2 8 1.5" THICK COUNTER TOP BUILDING PLUMatIG FIXTURE CALCULATIONS STEP 1: OCCUPANTS TOTAL AREA — DEDICATED STORAGE AREA OCCUPANT LOAD FOR "B" TYPE OCCUPANCY. OCCUPANTS 8700 eq.ft. -1192 sq.ft. 50 SHELVES ADJUSTABLE AT 1" INCREMENTS TOTAL OCCUPANTS Sr 150 50 (FIRST 50 OCCUPANTS) 100 (REMAINDER) STEP 2: PLUM. FIXTURES = 25 + 50 TOTAL PLUM. FIXTURES REQUIRED - 4 TOTAL PLUM. FIXTURES PROVIDED - 5 TOTAL H/C STALLS REQUIRED - 1 TOTAL H/C STALLS PROVIDED - 1 SHELF VIEW (CABINET DOORS REMOVED) .75" THICK LAMINATED SHELVES SOUTH ELEVATION SIDE EXISTING CABINET W/ SHELVES SCALE 1 " =2' NEW LAMINATE ALL SURFACES EXCEPT SHELVES PROJECT NO.: 05050 DRAWN BY: CJB ISSUE DATE: 08-09 -2011 SHEET REV.:. FLOOR PLAN, SCHEDULES 050501101— CO2.DWG CO2 SHEET 2 OF 5 v V V V VvvV REVISION ADDED EGRESS ROUTE INFORMATION AND SHOWED REVISED EXIT SIGNS 2011 -09 -12 1/4 SEC ' 23, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M. LIGHTING PLAN. SYMBOL LEGEND EXISTING GRID TO REMAIN. LIGI -IT FIXTURES TO BE REPLACED WITH NEW 3 -BULB T8 FIXTURES OFFICE RELOCATE EX EMERGENCY LIGHTING/ ENUNCIATOR DA TA, ;: -P IONE;-, AND ELEC.< OUTLETS TO BE REMOVED (TYP) OCC SENSOR SYMBOL LEGEND RELOCATE EMERGENCY LIGHTING OFFICE REVIEWED FOR CODE COMPLIANCE APPROVED KITCHEN STORA( 22T 'Wall Mount EX PHONE y(TYP) `,.. NEW ELECTRICAL OUTLET NEW DATA OUTLET NEW TELCO OUTLET City of Tukwila BUILDING DIVISION _33D NE BAT; NE, AND' ELE • 1 ETS,. ` INSTALLED ABOVE REMOVE EXIT�,SIGN LIGHTING EMERGENCY LIGHTING FIXTURE CEILING MOUNTED EXIT FIXTURE WITH DIRECTIONAL ARROWS AS INDICATED WALL MOUNTED EXIT FIXTURE FIRE ALARM MANUAL PULL STATION OCCUPANCY SENSOR r, NEVI DATA, PHONE, AND ELEC. OUTLETS INSTALLED ABOVE COUNTER SERVER ROO 2E oCC SENSOR__ TELCO ROOM ocC SENSOR GRAPHIC SCALE: 1/4'-1' -0' REFLECTED CEILING AND LIGHTING PLAN 05050EL01- CO3.0WG SHEET 3 OF 5 REVISIONS: SEE WALL TYPE SCHEDULE ALUM. E3REAKSNAPE TO MATCH GLAZING SYSTEM FINISH BLOCKING SEEAI -ANT BEAD WALL 0 GLAZING SCALE : 3' _ . I'-O" 7WMM -2 SEE WALL TYPE SCHEDULE 1. BREAKSHAPE • MATCH GLAZING. SYSTEM FINISH SEALANT BEAD GLAZING MULLION ALL 0 GLAZING MULLION SCALE • 3" = 11-0" 1WMM -I R - :2I INSULATION CONSTRUCT TENT PROM CEILING TILE MATERIAL. (TENT NOT REQLJZED P IC IDXTLIRE USED) -0. 7 .I2' -O• MAX: AGO STIGAL GEILI +16 TILE (2'x41 CEILING BRACING PLAN SCALE : I /4' ■ I'-0" BASE TYP. WALL 1 I /4 ". RAM-SET GONG. PINS 0 24" O.G. GONG. FLOOR WALL /FLOOR iC NNECTION SCALE _ 3' = I'-O ". METAL STUDS CONNECTED TO ROOF STRUCTURE AT 8' -0" 0.0 MAX. SUPPORTS ATTACHED DIRECTLY TO TOP PLATE OF WALL THROUGH OPENING M SAC LIGHT FIXTURE CEILING GRID CEILING TILE-- LIGHT FIXTURE INSULATION TENT. SCALE I' =11-0" SAC TYPICAL WALL _ WALL /— CEILING CONNECTION SCALE s I -1/2' • 1' -P1" ECS -3 (2) 2x6 STEEL STUD BOX BEAM .-. 665-,6 71x4' ACOUSTICAL CEILING TILE (A69- JOIST THREAD GLG... SUSP. WIRE \ATTAGHMEN GLG. WIRE 4 #I2 GA. WIRE SEISMIC DRAGE PER U8G STANDARD 25 -2 STRUCTURAL FRAh4 ACT 2x4 NOTE:: ENTIRE ACT SHALL I3E INSTALLED PER UBG STANDARD 25 -2 CEILING 4'-C" e�nON BRACING DETAIL SCALE = I/2" • I' -0" SEE IUAL.L TYPE LEGEND 9/8' GAM -SAC. 2F5-q WALL TYPE SCALE : I -I(2" = I'-O" 3 1/2" 25gat METAL STUDS • 21" O.C. 5/8" G.W.B. BOTH SIDES REVIEWED FOR CODE COMPLIANCE APPROVED SEP26:2011 City of Tukwila BUILDING DIVISION DEMO WALL SCALE: I -I/ • I' -(d" REMOVED LOWER PORTION aF WALL METAL STUDS CONNECTED TO LOOP STRUCTURE A O.C: TTASC: . SUPPORTS ATTACHE DIRECTLY TO TOP PLATE OP WALL THROUGH OPE SAC 45' METAL EDGE TRIM 1" CONF. JOINLCOMPOUN9 -" SAC TYPICAL WALL ALL / GEEING CONNECTION ALE s I -I/2" . 1'-0" 2WS-2 III HI,_ • INSULATE PIPES n COUNTER/SINK . MIRROR 5K SPOUT NEAR F.F. DR & FOUNTAIN D Iq" F.F GRAB B GB TO ' ISP - HANDHELD SHOWER W/ HO SC .. 1>: PROVIDE SOLID BLOCKING (TYPICAL) TOILET PAPER DI5P. T. RIM ELONGATED BOWL V F.F. URINAL" U FOLD SEAT SHOVER STALL DISPENERS/ kEGEPTAGLES biZ88 F TOILET ROOM FIXTURE MOUNTING HEIGHTS SCALE : 1/4" = 110" RECEIVED. CITY dFTUKVv9LA SEP 162011 PERMIT CENTER 17) cn g IR) cu o .5c) 0 Up-+ H Z co W W j 0 I 2 0� cc wZ 0 0 w • 1— z 0 . 0 oo co N ON 0 v c~7 8u. 0) co a .I W(OOQN CC Q• 3N • izt awWZ It It 0) . O IL O�Li� PROJECT NO 05050 DRAWN BY: CJB ISSUE DATE: 08-09 -2011 SHEET REV.: 05050DT01— C04.DWG C04 \ SHEET 4 OF 5 JJ REVISIONS: OCC SENSOR OCC SENSOR -6q-- ■•111111■ ■11511 L J <� y 2E 33D 4E OCC SENSOR OCC SENSOR 22T Wall Mount 2E 31T OCC SENSOR OCC SENSOR SYMBOL. LEGEND . 2E RECEPTICALS TO REMAIN RECEPTICALS TO BE REMOVED occ SENSOR F.E. EX. DATA OUTLET EX. TELEPI -LONE OUTLET CEILING MOUNTED EXIT. FIXTURE WITH DIRECTIONAL ARROWS AS INDICATED WALL MOUNTED EXIT FIXTURE FIRE ALARM MANUAL PULL STATION OCCUPANCY SENSOR FIRE ENUNCIATOR/STROBE REViEIi'ED FOR CODE COMPLIANCE APPROVED SEP 2 6 2011 i City of Tukwila BUILDING DIVISION GRAPHIC SCALE: 1/4' =1' -0' RECEIVER WI_ OF TIIKII�IILA SEP 16 2011 PERMIT CENTER ,0) Q ij0 to O_ U Qoxom o ow Z W (02 WW 20 0m CC wZ a. Ow IF— u_ 0 0 00 03 00 N 0� N 0 v 0 00 tL 0 do WoaN N XJ.. .. I--WWZ tQW0 Oa.LLo_ PROJECT NO.: 05050 DRAWN BY: VK ISSUE DATE: 08 -04-05 SHEET REV.: 09 -01 -05 05050EC01- C05.DWG C05 SHEET 5 OF 5