Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-301 - ACTION FURNITURE - ADA RESTROOMS
ACTION FURNITURE 730 ANDOVER PK E Dl 1 -301 City o*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049095 Address: 730 ANDOVER PK E TUKW Suite No: Project Name: ACTION FURNITURE DEVELOPMENT PERMIT Permit Number: D11 -301 Issue Date: 09/23/2011 Permit Expires On: 03/21/2012 Owner: Name: 790 ANDOVER LLC Address: PO BOX 287 , MEDINA WA 98039 Contact Person: Name: DAVID KEHLE Address: 1916 BONAIR DR SW , SEATTLE WA 98116 Contractor: Name: P HUNTER GENERAL CONTRACTOR Address: 17421 SE 298 , KENT WA 98042 Contractor License No: PHUNTGC 167JZ Phone: 206 - 433 -8997 Phone: 253 630 -2232 Expiration Date: 02/15/2013 DESCRIPTION OF WORK: REMOVE EXISTING RESTROOM, INSTALL (2) NEW ADA RESTROOMS WITH CEILINGS, AND DEFINE RETAIL TO WAREHOUSE W/ RACK SUPPORTED WALL (RACK SEPARATE PERMIT) Value of Construction: $8,000.00 Fees Collected: $401.49 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0025 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11-301 Printed: 09 -23 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read an governing this work will be compli N N N Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non - Profit: N Public: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or performance of work to this permit Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating • am authorized to sign and obtain this development permit and agree to the conditions attached el-tpu T� Date: 9 72-- 3 /7/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State doc: IBC -7/10 D11 -301 Printed: 09 -23 -2011 of Washington. • • 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 11: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ** *FIRE DEPARTMENT CONDITIONS * ** 15: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) doc: IBC -7/10 D11-301 Printed: 09 -23 -2011 24: Door handles, pulls, latches, locks and o operating devices on doors required to be essible by Chapter 11 of the International Building Code shall not requir t grasping, tight pinching or twisting of the t to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 27: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 28: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 29: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot -candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot -candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 30: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 31: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (EEC 901.4) 32: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 33: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 34: An approved manual fire alarm system including audible /visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2051. 35: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 36: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 37: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 38: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 39: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 40: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 41: Arty overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC-7/10 D11 -301 Printed: 09 -23 -2011 42: These plans were reviewed by Inspecto l . If you have any questions, please call Tul Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11-301 Printed: 09 -23 -2011 CITY OF TUKWIL• Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Imp: .1: 11 11 r tui,lt r/r 1:'rr.1'■ Building Permit No. 30 ( Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1019 414tax ea i006 L M Tenant Name: 461101\1 F1.1 Q N I TU ee Property Owners Name: 14O,qkW/VW- � Mailing Address: PO, e:tX King Co Assessor's Tax No.: "r ce2 191 otP Suite Number: Floor: New Tenant: jg1.....Yes ❑..No HE1DI isIPt City Wb . 91P3a CONTACT PERSON - who do we contact when your permit Is ready to be issued Name: GAY + ti* 1tii Mailing Address: 11k VP ?6Q % E -Mail Address: 4 F� h t @ G4 e htea rttl1 • COW1 Day Telephone: 'W(O - 433 `P1614 121n n U)b • Iht 160 Ciry AAte�,,� nn State Zip Fax Number: "1Jlp - 4 (, -b3(0 9 GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: i� Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: c140 001116 , 11 R61 -wro - Mailing Address: iq 1(o eDw e Vg Contact Person: Qvi(Q 1/ E -Mail Address: A lie i k e el IZaYt%1i • tyvlNl r I-trttL U . Into, City State e� 2Zip t(.0 Day Telephone: � - 4' '8 14 Fax Number: ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Zip Contact Person: E -Mail Address: Q:WppIications Worms- Application On L1'163-2006 - Pcimil Application doe Revlacd: 9.2()16 bh City Day Telephone: Fax Number: State Page I of6 BUILDING PERMIT INFORM ION - 206 -431 -3670 Valuation of Project (contractor's bid price): S D) 7 nnom�Y" J,M, Existing Building Valuation: S (itl1 IAAC4.1 V Scope of Work (please provide detailed information): E W1 1 CEIULkC, 4itIP a LA. Roo EXtstiLiq r s taco rt, l kIstbu. L e1 i, -10 LW/Etta-ft WI Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) _ 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: �` /�� Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:Gf v4-�}E "(/i��l'2e f orr Mice/Oise - PxJLr lL. Roods Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list o% maleriab and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safe_ ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. FIRE PROTECTION /HAZARDOUS MATERIALS: Q:`Applicaticnal arm►ApplieaionA On rine13-2l5 6. Pcm1H Applicuioadoc R.ovi ed: 9 -215t6 bh Page 2 of 6 Existing InteriorrRemodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1 " Floor p,�,, J! 0'"/ I() -- — / li 1j –�'[ hf/I 2nM Floor 3`d Floor Floors thru Basement Accessory Structure' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) _ 'For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: �` /�� Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain:Gf v4-�}E "(/i��l'2e f orr Mice/Oise - PxJLr lL. Roods Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ .......Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'yes', attach list o% maleriab and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safe_ ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. FIRE PROTECTION /HAZARDOUS MATERIALS: Q:`Applicaticnal arm►ApplieaionA On rine13-2l5 6. Pcm1H Applicuioadoc R.ovi ed: 9 -215t6 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.12 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW R O ' ' UPI RIZED AGENT: Signature: Print Name: VIL7 i mo ��}, Mailing Address: 11& I Q 140 05411E I LW. Date:aktr« Day Telephone: to-4374W 7" City State Zip Date Application Accepted: -31 -1` Date Application Expires: Staff Initials: Q: 1ApplicationslForms- Applicaliau On Um13-2006 • Permit Applicatino.doc Revised: 9 -21106 bh Page 6 of 6 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2623049095 Address: Suite No: Applicant: ACTION FURNITURE 730 ANDOVER PK E TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: D11-301 ISSUED 08/31/2011 09/23/2011 Receipt No.: Initials: User ID: R11 -02292 LAW 1632 Payment Amount: $63.00 Payment Date: 10/20/2011 10:19 AM Balance: $0.00 Payee: J.J.B. INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. ACCOUNT ITEM LIST: Description 7316 63.00 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 Total: $63.00 63.00 doc: Receiot -06 Printed: 10 -20 -2011 �J��� wqs City of Tukwila C J �J 190a • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049095 Permit Number: D11-301 Address: 730 ANDOVER PH E TUKW Status: APPROVED Suite No: Applied Date: 08/31/2011 Applicant: ACTION FURNITURE Issue Date: Receipt No.: R11 -02092 Payment Amount: $245.10 Initials: JEM Payment Date: 09/23/2011 11:14 AM User ID: 1165 Balance: $0.00 Payee: P HUNTER CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 354490 ACCOUNT ITEM LIST: Description 245.10 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 240.60 640.237.114 4.50 Total: $245.10 doc: Receiot -06 Printed: 09 -23 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049095 Permit Number: D11-301 Address: 730 ANDOVER PK E TUKW Status: PENDING Suite No: Applied Date: 08/31/2011 Applicant: ACTION FURNITURE Issue Date: Receipt No.: R11 -01906 Initials: User ID: WER 1655 Payment Amount: $156.39 Payment Date: 08/31/2011 10:19 AM Balance: $245.10 Payee: DAVID KEHLE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01583C ACCOUNT ITEM LIST: Description 156.39 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 156.39 Total: $156.39 doc: Receipt-06 Printed: 08 -31 -2011 -Aw INSPECTION RECORD Retain a copy with permit /)L. D t -361 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t✓ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION NO. Project: A'&`I o' - r /�.`tUIR Type of nspection: � kJ A R,..):0. Aa. Address: 13D . -NvXJCJ E. Date Called: Special Instructions: Q S 4 S C-6 ( / Date Wanted:. //�� a.m. Requester: Phone No: 7 0 .ct + o (0 07 Approved per applicable codes. a Corrections required prior to approval. COMMENTS: N N\ f..) L M P .' 1 I D -F--. ❑ REINSPECTION FEE REQ IRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. s �� �S INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj t: /t Type okInspec on: . Al 3 0 4 AJO U vu- 6 + Date Called: Special Instructions: , Fe s oc() , t ,c Date Wanted: ..."—_---103,. d: Z / _ (/ p.m. Requester: Phone No �y 7,d - `7 1' - .0 tG. C2 C7 �Approved per applicable codes. Corrections required prior to approval. COMMENTS: OW) R InspectorK Date:' 4a — z i-- t( n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTIQN NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vz► (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 -3°( Project 0A) •cd t A,`fvre Type of Inspection tA/ 5 . • . /-r.1, Address: `73O 1,04.)LLl- L. Date Called: • . Special Instructions: Date Wanted:. '� a in� / e9 -- (0 — ft p.m. Requester: Phone No: 2_t7(0 -g55 — o 60a . Approved per applicable codes. Corrections required prior to approval. et COMMENTS: ' �� / csif e. N . r a<: c a -n. • 1 Insppftor: Date :r f REfNSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 les (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Prolef_ / ..r . JN Rr rr irk--- Type of Inspection: c IM? Address: -73v AA1604 Date Called: Special Instructions: Date Wanted:. a.m. Requester: Y V' I Phone lqg- -$9 00 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: DNS .44 1T - OT 0 J AIV Y V' I 0Q (1.0 f 4 � I�.,, (-o / 2.eU � s ,3-1 1 --6 /-- �; (--oi vf7- .e 5 4,.-e - Nee a j -c'5 K -3 7-- 6( AL- ^- - — ,-1-0 L--1 a 11-Ai i - : c_ e i --- z)i- Inspect r: 'Date .,0 ❑ REINSPECTION FEE REQUIRE. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. -�v INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 F" (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project:,—, Pro' ct:, -, , . JAI J1)IN: Yaif Type Inspection: • t ArAA t/\;6 Addres : Date Called: Special Instructions: Date Wanted:. '0.--S'".' %l l a.m. p.m. Requester: Phone No: 2,0 -117 - 0 0 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1Inspect4!. IDate:,r,( ❑ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSP CTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IF., (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: -1 / G . �-� f....-_, ��/. �� Type f Inspectiop: y�A-M • 1 e Addre , J 0 t7dtj T £ Date Called: Special Instructions: Date Wanted: a.m. GI "Z�_(I Pm Requester: Ph e- 2i0 r- y .._ O G C7 O EJApproved per applicable codes. 1 erections required prior to approval. COMMENTS: KJ ST- ---A -o - Nor' ik*J _e pi „ pf&k( Inspector: r7 REINSPECTION FEE REQUIRE Id,. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit DI/ -.301 A L -5 - as 1 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project: /UC_�rd u - rty0•4�-ur� Type of Inspection: Se' Cov -ec-- Address: 7 3 0 4O Suite #: Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 6 4 - 70 Coo bfrA, , . h /otv -e �v,ti a eu Si' k QW . r n1 6Q-e.._._ Needs Shift Inspection: _ Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: z,, ca.._ Date: j /O! Hrs.: ( / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 than REVISIONS rtes shall be made to the scope of work without prior a T u�kwila Building vAron. of ;tf;sjGr�s 9 Division, will require a new plan submittal ` include additional plan review fees. SE,;IRITE PERMIT EaQU1RED FOR: Ciilechanical &Electrical RIM lumbing s Piping of Tukwila '"d" DIVISION xs \ OdrirvI N FILE. COPY : COPY raft No., b SO 1, r ^view approval is subject to errors and omlssions. of construction documents does not authorize on of eny adopted cods or ordinance. Rsce pt e Lproveci Fi91J Copy and conditions is acknowiedg d: R" COD A IEWED FO COMPLIAN ROVED 0 2011 OC T City of BUILDING E kwila IVISION Date: R CITY OF ECEIVED TUKW1LA 0 T 14 2011 PERMIT CENTER Cidy Of Tukwila BUILDING DIVISION REVISION 1)11 3oC l 1 91/4 IC H REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 0 2011 City of Tukwila BUILDING DIVISION • 1 BPX3MY DESCRIPTION Teknion OCIOBER 2009 FINISHES Monolithic Acoustical Panel with Vertical Wire Channel for use with 2008 Electrical Components 89X3180 Provides visual and acoustic privacy and allows for vertical cable passage from tap Panel frame finish. lay -in channel to bottom raceway within panel. Class "A" Fire rated fabric • Centre septum above raceway overlaid on either side with 1" fiberglass sound absorbent. • Acoustic rating of .70 NRC and 25 STC. Metal raceway cover standard in • Includes integrated vertical wire channel. corresponding frame color. PRODUCT PRICE SIZE /MM SIZE /INCHES WEIGHT VOL CODE GR1 GR2 OPT' H W H W LBS KG FP M' PX3MV3430 278 291 304 864 162 34 30 15 6.82 2.139 0.061 PX3MV3436 30) 330 357 864 914 34 36 17 7.13 2.540 0.072 PX3MV3442 324 349 377 864 1067 34 42 18 8.18 2.941 0.083 PX3MV3448 348 373 401 864 1219 34 48 20 9.09 3.342 0.095 PX3MV3454 371 396 424 1312 34 54 22 10.00 3.743 0.106 PX3MV3460 394 419 447 864 1524 34 60 24 10.91 4.144 0.111 PX3MV4230 303 320 338 067 762 42 30 17 1.73 2.852 0.081 PX3MV4236 327 361 391 061 914 42 36 19 8.64 3.387 0.096 PX3MV4242 353 392 428 061 1067 42 42 21 9.32 3.921 0.111 PX3MV4248 317 411 447 061 1219 42 48 23 10.45 4.456 0.126 PX3MV4254 403 437 473 067 1372 42 54 25 11.36 4.991 0.141 PX3MV4260 427 461 491 067 1524 41 60 27 12.21 5.525 0.156 PX3MV5030 385 410 438 270 762 50 30 19 8.64 3.370 0.095 PX3MV5036 416 467 521 210 914 50 36 22 0.00 4.002 0.113 PX3MV5042 445 496 550 210 1067 50 42 25 1.14 4.634 0.131 PX3MV5048 417 534 588 270 1219 50 48 26 1.59 5.266 0.149 PX3MV5054 506 557 611 270 1372 50 54 27 2.27 5.898 0.161 PX3MV5060 537 588 642 270 1524 50 60 29 3.18 6.530 0.185 PX3MV6630 450 492 538 616 162 66 30 12 0.00 4.407 0.125 9X3MV6636 482 550 622 676 914 66 36 26 1.82 5.234 0.148 PX3MV6642 515 583 655 676 1067 66 42 28 2.73 6.060 0.172 PX316V6648 . 548 616 688 676 1219 66 48 30 3.64 6.881 0.195 9831896654 579 647 119 676 1372 66 54 32 4.55 7.113 0.218 PX3MV6660 612 690 162 616 1524 66 60 34 5.45 8.539 0.242 DESCRIPTION FINISHES Monolithic Glazed Full- height glazing provides visual accessibility. Panel for use with 2008 Electrical Components • Glazing is replaceable on site. • Tempered glass standard. RE�/~9EVVEi� EOI� CODE COMPLIANCE APPROVEP OCT -:24 2 11 • L City of Tukwila PRODUCT PRICE CODE 89831865024 513 89831865030 651 8PX36165036 690 89831665042. 728 89831865048 766 89836466624 638 81136166630 694 89836406636 750 8983/306642 805 8983/806648 859 Panel frame finish. Metal raceway cover standard in corresponding frame color. SIZE /MM SIZE/INCHES WEIGHT- VOL H W H W LBS KG FP M' 270 610 50 24 25 1153 2.738 0.077 270 162 50 30 29 13.26 3.310 0.095 270 914 50 36 33 14.99 4.002 0.I13 270 1067 50 42 36 16.54 4.634 0.131 270 1219 50 48 41 18.48 5.266 0.149 616 610 66 24 33 15.20 3.581 0.101 616 762 66 30 39 11.57 4.401 0.125 676 914 66 36 44 19.94 5.234 0.148 616 1067 66 42 49 22.33 6.060 0.172 676 1219 66 48 54 24.70 6.881 0.195 `OPT = laminate, Whlaboord or Corkboard GlobalContract REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 0 2011 City of Tukwila BUILDING DIVISION Boulevard Systems Executive Office Page 2 of 4 Boulevard offers ingenious solutions for task-intensive, prone -to- change environments. Managers can easily accommodate additional employees and/or multiple shifts. Boulevard Systems Hoteling oulevard's floor -to- ceiling anel configurations provide rivacy. Elegant wood veneer furniture is distinctive for any executive. Boulevard makes perfect sense for people who come and go. Files are rolled out of a central storage depot for non - traditional workers who spend most of heir time away from the office. Boulevard Systems Management Office Boulevard includes panels and components, freestanding furniture, and casegoods that can be used separately or in combination to create highly individual environments. A http: / /www. globalcontract. com/view_data.php ?c ategory= Systems &sub_category = Bouleva... 10/5/2011 Joanna Spencer From: Todd Reedy Sent: Wednesday, September 07, 2011 7:25 AM To: Joanna Spencer Subject: RE: TI @ 730 APE D11 -301 Hello Joanna, An inspection at 730 APE revealed: -This space is part of a retail /warehouse complex with addresses 720 -790 APE. -The complex is served by a single fireline connection that is current on backflow prevention install and testing. There is an 8" DCDA inside the building and the FDC has a Storz adapter. The next test is due November 2011. - The property is served by two 2" domestic meters. One of the services (south of the building on Minkler Blvd) is being used for just irrigation and has a 1" DCVA installed but it is overdue for testing. The last time it was tested was October 2009 and the property's test month for all the backflow preventers is November. - The other water service is used for domestic use and has a 2" RPPA installed, however it is inside the building. This RPPA is current on testing with the next test due November 2011. Let me know if you have any questions, Todd From: Joanna Spencer Sent: Tuesday, September 06, 2011 11:54 AM To: Todd Reedy; Han Kirkland Subject: FW: 11 @ 730 APE D11 -301 Hello - Are they current on their backflows ? Thanks, Joanna PERMANENT ANENT FILE COPY D11301 IWERM1T COORD COP)* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -301 DATE: 10/14/11 PROJECT NAME: ACTION FURNITURE SITE ADDRESS: 730 ANDOVER PK E Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: ,II din. 1i ision Public Works ti Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete, Incomplete DUE DATE: 10 /18 /11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 /15 /11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only . CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *PE Ya PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -301 PROJECT NAME: ACTION FURNITURE SITE ADDRESS: 730 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # DATE: 08 -31 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ter rill ll gD�ionOl i ril Public Works iwt‘ rfok,.o cf Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 09-01-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required No further Review Required n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-29-11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: ('CI0 111)k I(Zjy �11(i PERMIT NO:• SITE ADDRESS: 1'2 Q 0 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 4I'Ulk q ` /4?-6/// Summary of Revision: p-pb t Lo N D V.r✓ QA,0 -1101) Received by: 4/7,/,L., REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Cif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /O/ . /Z o d / Plan ChecWPermit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Dil-9,ol © Revision # f after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Ac-st 0a ■j t/,4 4-9s e4 /1/4.) Project Address: % 3O AN Op ✓.k.2 PAO cc F 5T Contact Person: Pffn. i-,-' fir. re_ Phone Number: 2O 6 - 49 9- 06043 Summary of Revision: /too re K All d,-' c' # r cr 0,7•4 e27 s-r ■ a ry ?ii ,e. v� envRnCE!V p WILA OC '"EAMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: kEntered in Permits Plus on H:\AppliationsWotms- Applications On Line\2010 Applications \7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7 -2010 Contractors or Tradespeople Poer Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name P HUNTER GENERAL CONTRACTOR UBI No. 600519622 Phone 2536302232 Status Active Address 17421 Se 298Th License No. PHUNTGC167JZ Suite /Apt. License Type Construction Contractor City Kent Effective Date 4/9/1984 State WA Expiration Date 2/15/2013 Zip 98042 Suspend Date County King Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date HUNTER, PHILIP Owner 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 12 CBIC SF4788 03/27/2004 Until Cancelled $12,000.00 04/28/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 CBIC INSSF4788 03/27/2011 03/27/2012 $1,000,000.0002 /09/2011 6 CBIC INSSF4788 03/27/2004 03/27/2011 $1,000,000.0001 /28/2010 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip /Print.aspx 09/23/2011 CONTINUOUS TOP TRACK 6" CEILING JOISTS (SEE 5TH T -3X1)/ SOUND aATT INSULATION IIIIIIw , 1,063 P. '4. WA HOUSE = 16.785 5 TOT =: 16,185 5'. .311 SPACE 720 TOTAL = 18,365 5F. EXISTING WARE FILE COP ' Permit No. ` Plan Ievfew a rovat s errors and am! „-'..;� App ,xi of construction documents does not out thy; VI !on of any adopted cad or ordinance. Re of - , , , . / j88Clb�,. REVIEWED FOR CODE COMPLIANCE APPROVED SEP 2 1 2011 City of uk �1 BUILL1IM.._.,,_ ISION 0 O. U 8 [t1 cki ANDOVER PARK EAST 13UILP INCA AND 5I 'M STATISTICS: BUILDING CODE :' IBC 2009 ZONING: TUC SITE AREA: APPROX. 2:9 ACRES EXISTING BI.IOG. FOOTPRINT NET): 63,120 SF TENANT AREA: 130 • 13385 SF. WAREHOUSE (130))= 4,253 SF. BULK RETAIL (130)■ 9,052 5F. ATTACH BOTTOM TRACK TO CONC. FLOOR IU/ POWDER DRIVEN ANCHORS AT 24" O.C. 5/8" GYP. BP. (TYPE 'X' • FIRS RATED WALLS.) OCCUPANCY GROUP: M RETAIL, 5 -1 WAREHOUSE TOTAL PARKING EXISTING: 94 NO CHANGE TYPE OF CONSTRUCTION: V -B (FULLY SPRINKLED) TOTAL SQUARE FOOTAGE ALLOCATION SUITE 120 : RETAIL • 11,302 SF SUITE 110 : RETAIL = 0 SF SUITE 190 RETAIL = 2,000 SF TOTAL : RETAIL • I3„302 SF SUITE 130 : RETAIL = WV SF TOTAL : RETAIL ■ 22294 SF WHSE ■ 1063 SF WHBE = 16,185 SF WNW = 13,185 SF WHSE = 31033 5F WISE = 4,253 SF WHSE = 41,326 5F RETAIL; 22,254 5,F. • 2.511000 = 56 CARS W1-15E.: 41 ,326 SF. 1 1/2000 ■ 21 CARS 11 CARS SCOPE OF WORK: (: INSTALL I NEW 4DA RESTROOM AND CREATE NEW RETAIL AREA WITH PLYWOOD SEPARATION ON BACK OF RAKING APPROXIMATE CASTS: $ 6000 APPROXIMATE EVALUATION: *5.8 MILLION OLUNPR 190 ANDOVER LLC A: BOX 281 MEDINA, WASHINGTON 98039 425 - 451 -1511 TAX IQ NUMBER 262304 - 9095 -06 SEPARATE PERMIT REQUIRED FOR: Mechanal peCblcal 0 Plumbing Gas Piping City of Tukwila BUILDING DIVISION LEGAL DFSCRIPTION THAT PORTION OF THE NORTHEAST QUARTER OF THE SOUTHEAST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, RANGE 4 EAST, W. M. IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: BEGINNING AT NE SOUTHWEST CORNER OF LOT 8 OF NE PLAT OF ANDOVER INDUSTRIAL PARK NO. 5, A6 RECORDED IN VOLUME 83 OF PLATS, PAGES 22 AND 23, N KING COUNTY, WASHINGTON* THENCE SOUTH 01041'28” ZEST ALONG THE SOUTHERLY EXTENSION OF NEWEST LINE OF SAID LOT 8, A DISTANCE OF 545.00' FEET TO THE TRUE POINT OF BEGINNING* THENCE SOUTH 88012'32" EAST, A DISTANCE OF 291.00 FEET± THENCE SOUTH 0104T28" WEST, A DISTANCE OF 42221 FEET± THENCE NORTH 88012'32" WEST, A DISTANCE OF 241.00 FEET TO ,4 POINT OF CURVE± THENCE ALONG .4 CURVE TO THE RIGHT HAVING A RADIUS OF 50 FEET AND A CENTRAL ANGLE OF 90000'00 ", AN ARC DISTANCE OF 18.54 FEET TO THE EASTERLY MARGIN OF ANDOVER PARK EAST± THENCE NORTH 01041'28" EAST, A DISTANCE OF 312.21 FEET TO THE TRUE POINT OF BEGINNING. 1. EXISTING ROOF 15 INSULATED W/R -21 WITH F.5, 25 FACING 2. EXISTING ADJACENT TENANT SP ES TO 120 BOTI-I SIDES ARE ARE ALREADY HEATED. 3. EX. STOREFRONT 1S ALUMINUM E W/THERMAL BREAK AN 1" OVERALL CLEAR INSULATED GL WITH 1/2" AIR SPACE lU - 060) WITH SHGC = .45 4. MEAT IS VIA GAS, NO ELECTRIC AL . CAULK AND SEAL ALL OPENINGS T WEATI•IERSTRIPING AT ALL EXTERIO MAXIMUM ALLOWABLE LOAD FOR 5W1 LIGHTING: EXISTING LIGHTING TO REI' RELOCATE AS REQUIRED. ED. TSIDE, INCLUDE OORS. IS 80% of 20 AMP. CIRCUIT. IN, 140 CHANGE IN WATTAGE, SITE PLAN 4 VICINITY MAP GENERAL DATA PROPOSED FLOOR PLAN BLOW UP FLOOR PLAN RESTROOM AND\LEVATION REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division: NOTE: Revisions will require a new plan submittal and may include additional plan MI fees. DOOR SCNgDULE EXISTING STOREFRONT POOR WITH LOCKSET, CLOSER, WEATHERSTRIP, 1/2" MAX. THRESHOLD Q EXISTING 3'X1' WOOD DOOR WITH. METAL FRAME, PRIVACY LOCK Q EXISTING OVERHEAD DOOR ▪ EXISTING: 3'X1' HOLLOW METAL DOOR WITH METAL FRAME, LOCKSET EXISTING OVERHEAD DOOR • EXISTING 3'X1' HOLLOW METAL POOR WITH METAL FRAME, LOCKSET • EXISTING OVERHEAD DOOR WALL SCHEDULE: m EXISTING 6 "X25 GA. SM. STUD WALL TO 10' AFF Vs" GYP. BOARD W/ R -2I INSULATION TO 10', R -2I STICK PIN INSULATION o 10' TO ROOF, VAPOR BARRIOR ON WARM SIDE. (Us 000) m EXISTING 6 "X20 GA. 5TL. STUD * 24" 0.C. FOR 26' HEIGHT, FULL HEIGHT TO ROOF DECK W/ %'' GYP BOARD EA SIDE NON - INSULATED, PAINTED PTE: 1. THE EXIT SIGNS SHALL BE ILLUMINATED WBATTERY BACK -UP AND EMERGENCY LIGHT IEXITI 2. PROVIDE EMERGENCY LIGHTING W/ BATTERY BACK -UP TO MEET COms REMOVE EXISTING RESTROOM, WALLS, FLOORING, PLUMING FIXTURES, CEILING ETC, PREP FOR NEU1 RESTROOMS DEVQ FLOOR PLAN SCALE 1 /16 " =1 0" NOTE: EMERGENCY LIGN?ING FACILITIES SHALL ARRANGED TO PROVIDE INITIAL. ILLUMINATION THAT IS AT I.EAST AN AVERAGE OF 1 FOOT- CANDLE AND A MINIMUM AT ANY PONT CF 0.1 FOOT-CANDLE MEASURED ALONG THE PATH OF EGRESS AT FLOOR LEVEL. ILLUMINATION LEVELS SHALL BE PERMITED TO DECLINE TO 0.6 FOOT- CANDLE AVERAGE MP A MINIMUM AT MY POINT CC 006 FOOT - CANDLE AT THE END' CF THERGANCY LIGHTING TIME DURATION. A MAXIMUM -TO -MINIM ILLUMNATION UNIFORMITY RATIO OF 40 TO 1 SHALL NOT 13E EXCEEDED. NEW PERMANENT ANENT PLYWOOC WALL ATTACHED TO NEW I RACKING TO DEFINE WAREHOUSE AND-RETAIL PATHWAY LIGNtINC� .4 : T; ED FOR CODE COMPLIANCE ROVED Sp 21 2011 Ct EX .HEATED ENYIRV'1ENT EX -R-21 BA7i IN3lJItA7tON EX. ROOF DECK; FS 25 FACING SULK RET,41L (9,092 OCC. 9,(A92Ig 1/30.: 303 5F) OCC T WO EXITS, 03 x .15 =46" PROVIPEP EX. HEATED ENVIRONMENT EX. R- 21134TT INSULATION EX. ROOF IPECK, FS 25 FACI1 PATHWAY LIGHTING EX. LOADING DOCK JINNI 0 MIN BIM SAW r MAW MEN/ MEW ISM NMI IMMO NMI MEM ■ter■ ■■�w \ \Wkst -4 \documents \CAD\2003 \0369 BREKKE PRQP\SUITE 730 CD 08- 30- 11 \T -1,T- 2,T-3.DWG, 8/30/20113:45.49 PM, DMAAAR MAIN 1 LIGHTING ENERGY CODE NOTES: 1. CHANGES TO EXISTING MAIN LIGHTING UNDER SEPARATE PERMIT (RETAIL 11 WATTS PER SF., WAREHOUSE AT 0:5 WATTS PER SF) 2. ADD NEW 2 QULB COMPACT FLUORSECENT WALL MOUNTED LIGHT FIXTURE IN NEW RESTROOM 20 WATT EACH = 40 WATTS. ALLOWAt3LE 15 52.5 SF X .9 : 41 WATTS 3. MAXIMUM WATTAGE PER %WITCH IS 80 % OF 20 AMP CIRCUIT. PROVIDE EXHAUST FAN TO OUTSIDE, TIE TO LIGHT SWITCH PER MECH. CODE NEW 6" X 20 GA STEEL JOISTS AT 24" O.C. WITH 5/8" GYP 130 AND 1/2''' PLYWOOD ON TOP, SOUND INSULATE PROVIDE EXHAUST FAN TO OUTSIDE, TIE TO LIGFNT SWITCH PER MECH. CODE REELECTED CEILI\C SCALE: 1/4"=1'0" GYP. BD. PAINTED SEMI -GLOSS ENS PLASTIC LAMNATE WAINSCOT 11 /4" DIA:GR43 BARS HORIZ. AND VERT.. COVED FRONT REViE:V1 CODE COMPLIANCE APPROVE SEP 21. 2011 City of TuIcwila INSULATE EXPOSED WATER SUPPLY LINES -- AND DRAINPIPES UNDER LAV.' NO SWARPOR ABRASIVE SURFACES SHALL OE EXPOSED UNDER THE LAY. SIDEROQr1 SCHlE I FLOOR NEW SHEET VINYL BASE: NEW 6" COVED SHEET VINYL WALLS: NEW 4' PLATIC LAM WAINSCOT ALL WALL$ NEW GYP BD PAINTED (SGE) ABOVE CEILING: NEW GYP.13P. PAINTED (SCE) 2 FLOOR: SHEET VINYL 84$E: b" COVED SHEET VINYL WALLS: 4' PLATIC LAM WAINSCOT ALL. WALLS GYP. I30. PAINTEP (SrsE) A80VE CEILING: GYP.BD. PAINTED (BCE) 3 FLOC EX. CONC. BASE: 4" RUBBER ;BASE WALLS: GYP. 8P PAINTED (EE) CEILING: EXP. TO STRICTURE .1790ft SCHEDULE El EX 3' -0" X 'I' -0" STET DOOR WITH 1/2 THRESHOLD, CLOSER, WEATHERSTRIP E2 NOT USED NEW 3'4" X 1' -0" S.C. WHOOP DOOR W/ PAINTED METAL FRAME W/ I I/2 PAIR BUTTS (HINGE CLOSER); PRIVACY LOCK WALL STOP, SILENCERS WALL SG 4 PULE: NEW 3 I/2 "X20 GA. STL. 511.1D WALL TO 10' AFF PERIMETER TO CEILING INSIDE WITH 54" GYP. 84AR0 :E.S. (WATERPROOF GYP. 80. IN RESTROOM$»OUND INSULATE LLS. LIJ000 DOOR HOLLOW METAL DRY WALL 'FRAME 5/8" GYP. 8D. BOTH SIDES STEEL STUDS 4-1, nT11u41.1ti0111111110 1.•ti '.....Yr., SECTION ►!wirer d►.lMrrrn,nnfelrenVInATUTZAo RDPI1 VP DDnc►CI ITT= 7211 .rn n11.2n_1 i \T_1 T_7:T_2 man QPPA! fl11 2.e�.