Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-332 - WESTFIELD SOUTHCENTER MALL - THE COOL - TENANT IMPROVEMENT
THE COOL 988 SOTJTHCENTER MALL Dl 1 -332 City olhukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 988 SOUTHCENTER MALL TUKW Suite No: Project Name: THE COOL Permit Number: D11 -332 Issue Date: 11/01/2011 Permit Expires On: 04/29/2012 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARK HILLIARD Address: 2601 4 AV #350 , SEATTLE WA 98121 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Contractor License No: BNBUII *990K3 Phone: 206 718 -1896 Phone: 206 382 -3443 Expiration Date: 09/12/2013 DESCRIPTION OF WORK: NEW TENANT: ADD ALUMINUM STOREFRONT, GLAZING, AND GB HEADER. (SEE EXPIRED PERMIT D10-245) Value of Construction: $10,000.00 Fees Collected: $273.75 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 011 -332 Printed: 11 -01 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: OS. Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wort 1- authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: {V1tAr24 A I--1) U \ ;e, r Date: l 1 1, 1 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. doc: IBC -7/10 D11 -332 Printed: 11 -01 -2011 7: Remove all demolition rubble and loose '-ellaneous material from lot or parcel of grou roperly cap the sanitary sewer connections, and properly fill or oth e protect all basements, cellars, septic tank s, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tulcwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors m the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface m accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 min). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinter heads. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: IBC -7/10 D11 -332 Printed: 11 -01 -2011 26: All new sprinkler systems and all mod' ons to existing sprinkler systems shall have f epartment review and approval of drawings prior to installation or modification. New sprinkler systems and all mo ations to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: Post address on storefront per approved Westfield Standards. 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -332 Printed: 11 -01 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA qov Mechanica Permit No. Plumbing /Gas Permit No. orks Permit No Project No, (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: .880 Southcenter ktmk King Co Assessor's Tax No.: 920547 -0010 Tenant Name: The Cool Property Owners Name: WEA Southcenter, LLC. Mailing Address: 2800 Southcenter Suite Number: - 9'88— New Tenant: Tukwila City Floor: 1 ❑ Yes m .. No State 98188 Zip CONTACT PERSON - e contact when your permit is ready to be issued Name: Mark Hilliard Mailing Address: 2601 4th Ave #350 E -Mail Address: mark.hilliard @bnbuilders.com Day Telephone: (206) 718 -1896 Seattle City Fax Number: (206) 382 -3440 WA state 98121 Zip GENERAL CONTRACTOR INFORMATION - (Contractor Information for Mechanical (fig ,:4) "for Plumbing and G Piping (Pt; 5))''. Company Name: BNBuilders, Inc. Mailing Address: 2601 4th Ave #350 Contact Person: Mark Hilliard E -Mail Address: mark.hilliard @bnbuilders.com Contractor Registration Number: BNBUII *990K3 Seattle City Day Telephone: 98121 State (206) 718 -1896 Zip Fax Number: (206) 382 -3440 Expiration Date: 12/31/2011 ARCHITECT OF RECORD "- All plans must be stamped by Architect of Record Company Name: S.M. Stemper Architects, P.L.L.0 Mailing Address: 4000 Delridge Way, SW Suite 200 Contact Person: Wayne Johnson E -Mail Address: wayne@stemper.com Seattle City Day Telephone: 98106 State (206) 624 -2777 Zip Fax Number: (206) 624 -2973 ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: N/A Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATION — 206 - 431 -3670 Valuation of Project (contractor's bid price): $ 10,000.00 Existing Building Valuation: $ Scope of Work (please provide detailed information): Add aluminum storefront and glazing and GB header Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below IS` Floor 2 "a Floor 3ra Floor Interior Remodel 974 Addition to Existing Structure Type of Construction per IBC Type of Occupancy per IBC Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Ca sort Covered Deck Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes m No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application' Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: Print Name: Mark Hilliard Mailing Address: 2601 4th Ave # 250 Date: 10, i i, 1 1 Day Telephone: 206.718.1896 Seattle City WA State 98121 Zip Date Application Accepted: to Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line \2010 Applications \74010- Permit Application.doc Revised'. 'l -2010 bh Pagc 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: D11 -332 Address: 988 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 10/11/2011 Applicant: THE COOL Issue Date: Receipt No.: R11 -02379 Initials: User ID: Payee: WER 1655 Payment Amount: $143.90 Payment Date: 11/01/2011 08:55 AM Balance: $0.00 MARK HILLIARD TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11792 143.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 139.40 640.237.114 4.50 Total: $143.90 doc: Receiot -06 Printed: 11 -01 -2011 • • (N�`LA wqs City of Tukwila ``?�yti Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11 -332 Address: 988 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/11/2011 Applicant: THE COOL Issue Date: Receipt No.: R11 -02218 Payment Amount: $129.85 Initials: BLH Payment Date: 10/11/2011 01:12 PM User ID: ADMIN Balance: $334.67 Payee: BNB BUILDERS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 61479 129.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 129.85 Total: $129.85 doc: Receipt-06 Printed: 10 -11 -2011 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proje . : ' - t kAJ PG4 PIG( cif 0P°1-4-/ Type of Inspection: l i ►.1 A Address: � 4?› INAAtt Date Called: Special Instructions: Date Wa ted: 11 C N f 1 1 a.m. p.m. Requester: Phone No: • Approved per applicable codes. 1 Corrections required prior to approval. COMMENTS: tvl } (fie -vv lF { P Date: /sib/ 1 I / sib SPECTION FEE REQUIRED. Prioe'to next inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ERMIT COORD COP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -332 PROJECT NAME: THE COOL DATE: 10 /11 /11 SITE ADDRESS: 988 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS �. �P . IrtT �'V Building Divi Ion glicwo,s(Pc. A:' Atm- t - -41 NAB Fire Prevention Planning Division Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/13/11 Complete 1:k Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 /10 /11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name B N BUILDERS INC UBI No. 602056687 Phone 2063823443 Status Active Address 2601 4Th Ave Ste 350 License No. BNBUII`990K3 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/23/2001 State WA Expiration Date 9/12/2013 Zip 98121 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company icenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTESL913K1 WESTERN STATES LOGISTIX LLC Construction Contractor General Unused 5/8/2009 5/8/2013 Active BASTINB0000J BASTIAN NIELSEN BUILDERS INC Construction Contractor General Unused 9/11/2000 9/7/2001 Archived PURODSI984JN PURODI SYSTEMS INC Construction Contractor Plumbing Unused 6/19/2002 7/2/2010 Expired Business Owner Information Name Role Effective Date Expiration Date BASTIAN, BRADLEY JAMES President 05/23/2001 Bond Amount NIELSEN, JEFFREY J Vice President 05/23/2001 6642084 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 INS CO OF AMERICA 6642084 06/02/2009 Until Cancelled $12,000.00 06/05 /2009 4 HARTFORD FIRE INS 52BSBBK5617 01/01/2002 Until Cancelled 06/02/2009 $12,000.0012/04 /2001 3 TRAVELERS CAS & SURETY CO 103355900 08/30/2001 Until Cancelled 04/07/2009 $12,000.0009/06 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 Zurich American Ins Co GLA380504401 09/07/2011 09/07/2012 $1,000,000.0009 /01/2011 12 ZURICH AMERICAN INS CO gla380504400 09/07/2010 09/07/2011 $1,000,000.00 09/07/2010 11 WAUSAU UNDERWRITERS INS. CO TBJZ91442966029 09/07/2009 09/07/2010 $1,000,000.00 09/03/2009 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/2008 09/07/2009 $1,000,000.00 09/05/2008 https://fortress.wa.gov/lni/bbip/Print.aspx 11/01/2011 WESTFIELD MAL T Code Summary CODE SUMMARY: - WASHINGTON STATE BUILDING CODE WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN TO 5E SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. THIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK IN PREPARATION FOR FUTURE TENANT. SITE INFORMATION: TENANT SPACE 444 TENANT ADDRESS: 988 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 910241- 0010 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: 914 S.F. TOTAL REVISED SQUARE FEET: 914 SF - NO ADDITIONAL TENANT SQUARE FEET AS PART OF THIS WORK OCCUPANCY GROUP: WESTFIELD MALL - M COVERED MALL OCCUPANCY LOAD (TABLE 100411): OCCUPANCY LOAD FACTOR - 30 5F/ 914 / 30 32 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 'M' IS 49. (TABLE 1015.1) OCCUPANCY LOAD IS 32 THEREFORE ONE EXIT REQUIRED. TWO EXITS ARE PROVIDED THEREFORE OK MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED THEREFORE ACCEPTABLE EGRESS WIDTH - 32 (.2) m 6.5 INCHES - PAIR OF 36" WIDE DOORS SHALL BE PROVIDED AT MALI.. STOREFRONT AND EXISTING EXIT DOOR TO BACK OF HOUSE CORRIDOR IS 36'1 WIDE - THEREFORE OK TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM 15 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 250 - THEREFORE OK SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT O. ENTRANCE TO THE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WITHIN TENANT SPACE I5 LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.4.5.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL BE PROTECTED BY 1 -14OUR FIRE DOOR ASSEMBLY THAT IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.4.83. SECTION 402.12 - EACH TENANT SHALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL AT SOUTHCENTER REFR NT T R T General Notes 1. ALL WORK TO BE PERFORMED N COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. • CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL HAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OF THE BUILDING INDUSTRY. DRAWINGS SHOW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT SHOW EVERY DETAIL. 1. DETAILS SHOO! IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. C,,NTRACTOR TO PROTECT EXISTING FURNISHINGS, FIXTURES, EQUIPMENT AND LANDSCAPING PROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OIINER, NCLUDNG: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OM ER. 10. ALL INTERIOR GWB IS I" • TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GLIB. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PiZOVIDE FINISH WALL BEI•IIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E- 2A -105C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, IS. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" AT AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 18. FURNISH AND NSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON THE PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. Scope of Work SCOPE OF WORK SHALL INCLUDED THE LANDLORD BUILD OUT OF TENANT IMPROVEMENT TO ,4N EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER IN PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: - CONSTRUCTION OF NEW TENANT MALL STOREFRONT - CONSTRUCTION OF NEUTRAL PIERS AT TENANT MALL STOREFRONT - INSTALLATION OF TYPE X GYPSUM WALL BOARD ON EXISTING WALLS WITHIN TENANT SPACE AND PAINT EXISTING DESIGNATED WALLS TO A LEVEL 4 FINISH Drawing Index ARCHITECTURAL T0.0 TITLE - COVER SHEET A1.0 FLOOR PLAN, ELEVATION, WALL SECTION, AND DETAILS ■ Separate Permits . _. L.. _ •y l li_. L. ^ate._ S _ it B' ► 1_ • ...1 - . ►.)r SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING U\A • ____ ____ T SEPARATE PERMIT REQUIRED FOR: Mechanical lectrical Plumbing 1206as Piping City of Tukwila Li?)-DING DIVISION PLANNING APPROVED No chameleon be made.to plans without appro l from Vie Plaint n Division 410 DCD � Project Directory WEA SOUTHCENTER LLC 2800 Southcenter Seattle, WA 98188 SENIOR GENERAL MANAGER: ANDREW CIARROCHI . T - 206246.0423 F - 2062448601 MALL OPERATIONS: PAT BURNS T - 206246.0423 F - 2062448601 C - 206186.9011 PBURNSCIESTFIELD.COM ARCHITECT 5M. STEMPER ARCHITECTS, P.LL.C. 4000 Delrfdge Way SW Suites 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -211'1 (206) 624 -2913 FAX wayneeemstemper.com PY Permit mil No, )Plan reviewx7 approval Is to em and omission. �1�. . •�^•F 7:4# of construction documents does not authorize Pt: .. D ion of any adopted code or ordinance. Rece pt Lp provad Field Coy s acknowledged: z By Date : 1 , 1 , 1 I City Of rUkwih BUILDING DIVISION REVISIONS 1!9 changes shall be made to the scope of work without prior approval of Tukwila Building Division. Fisvisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED mervyrrs 2 LEVELS TENANT. SPACE 988 SOUTHCENTER NORDSTROM 3 LEVELS 3 LEVELS NORTH RECEIVED CITY OF TUKWILA OCT 1 1 2011 PERMIT CENTER DII-332 17�St%ZC'� Sou th cen ter 833 Sauthcentar Parkway TDIMa, WA., 96166-2888 200- 240 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile • 310 478 4468 THIS ORAMNO IS AN NSTRUAENT OF SERVICE. IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECTS PERMISSION NM UNLESS THE REPRODUCTION CARRIES THE ARCHITECTS NAME. ALL OESIGN AND OTHER INTORMATION SHOWN ON THE DRANNO ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT ■ S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 z 2 w >z O O a_ I-- I-- 0 z © co ct LL Q O* I- Z z W ISSUE cog W�-- I- CO C) W Q co D CD I'- ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA #1022.10 CELING 14'-0" AFF wi Z: at. 6 •. A1.0 (E) NEUTRAL PIER PATCH GUJE3 AND PAINT - LEVEL 4 FINISH BOTTOM OF MULLION 101-0" (E) STEEL COLUMN BEYOND STONE 15,45E - OWNER FURNISHED, CONTRACTOR INSTALLED FIRST LEVEL FF 0._011 A 1 (E) CEILING AT MALL CONCOURSE ALUM. BREAK METAL SHAPE (E) NEUTRAL PIER PATCH GM AND PAINT - LEVEL 4 FINISH DEMO (E) GRANITE - FULL HE IGHT OF NEUTRAL PIER • , • PAIR OF GLASS ENTRY DOORS - RE: SCHEDULE STOREFRONT ELEVATION 1/4" - INTERIOR GLAZED AREAS (Store front glazing) Where interior glazing is installed adjacent to a walking surface, the differential deflection of .two adjacent unsupported edges shall not be greater than the thickness of the panels when a force of 50 pounds per linear foot (plf) is applied horizontally to one panel at any point up to 42 inches above the walking surface. (IBC Section 2403.4) CEILING 14'-�" AP (E) CEILING AT MALL CONCOURSE ALUMINUM BREAK METAL SHAPE AT TOP Of STOREFRONT BOTTOM OF MULLION 101-0" PAIR OF STOREFRONT DOORS - TYPICAL + FIRST LEVEL FF 01-0" V (E) METAL STUD FRAMING TO REMAIN (E) STEEL BEAM • TO REMAIN )" THICK GLAZING - TEMPERED BUTT GLAZED AT VERTICALS (E) STEEL COLUMN TO REMAIN DOOR HARDWARE - SEE SCHEDULE (E) FLOORING TO REMAIN ENTRY WALL SECTION 1/2" = 1'-0" STONE BASE - OWNER FURNISHED, CONTRACTOR INSTALLED (E))i" REVEAL TO REMAIN STONE 13A8E - REPLACE AS REQUIRED. AT NEUTRAL PIER )6" ALUM. REVEAL MALL STOREFRONT FRAM - ALIGN TO LEASE LINE TENANT STOREFRONT MALL COMMON AREA • • •MS• • • M.= • • •■■• • • •11•••, ) THICK GLAZING - TEMPERED -BUTT GLAZED (E) METAL STUD AND GLUES TENANT DEMISING WALL +/- 4V-1 3/4" +/- 12'-3 1/4" OUTLINE CV SOFFIT ABOVE H •■•••■••••■■•••■■••••••• (E) GWE3 PROVIDE LEVEL 4 FINISH CONCRETE FLOOR TO REMAIN • 4■I • ••••■ IMMM • • •■•• • =M. • • OM. • • 1•••• ••■•• dn.= ••••• ■••■•■ LEASE LINE ••■ • • .■ • CONTRACTOR SHALL INSTALL VACANT TENANT • GWE3 AT WALL AS REQUIRED SPACE TO FINISH SHEATHING AND PAINT TO LEVEL 4 FINISH 100 H (E) GUJ15 - PROVIDE LEVEL 4 FINISH +/- 4'-6 1/2" +/- 3'-5" (E) ELECTRICAL PANEL • RE: ELECT. (E) DOOR TO REMAIN 6 (E) STOCK ROOM 101 NO WOW IN (E) STOCK ROOM LEASE LINE • •••••••••••■••••■•••■•••••■■■••• • .4•••• ••••• • • Min. • • ••••• • • MOM • LEASE LINE 60-10" .•M•• • • Olm•PI • • ••••I, MOM OWNS • • 11•1••• • • ■■• • • ■■■ 0 NORTH , FLOOR PLAN 1 4" = 11-0" DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE 11 ‘ DOOR MATL. HM FR. TYPE FRAME MATL. RATING STONE 15,45E - OWNER FURNISHED, CONTRACTOR INSTALLED FIRST LEVEL FF 0._011 A 1 (E) CEILING AT MALL CONCOURSE ALUM. BREAK METAL SHAPE (E) NEUTRAL PIER PATCH GM AND PAINT - LEVEL 4 FINISH DEMO (E) GRANITE - FULL HE IGHT OF NEUTRAL PIER • , • PAIR OF GLASS ENTRY DOORS - RE: SCHEDULE STOREFRONT ELEVATION 1/4" - INTERIOR GLAZED AREAS (Store front glazing) Where interior glazing is installed adjacent to a walking surface, the differential deflection of .two adjacent unsupported edges shall not be greater than the thickness of the panels when a force of 50 pounds per linear foot (plf) is applied horizontally to one panel at any point up to 42 inches above the walking surface. (IBC Section 2403.4) CEILING 14'-�" AP (E) CEILING AT MALL CONCOURSE ALUMINUM BREAK METAL SHAPE AT TOP Of STOREFRONT BOTTOM OF MULLION 101-0" PAIR OF STOREFRONT DOORS - TYPICAL + FIRST LEVEL FF 01-0" V (E) METAL STUD FRAMING TO REMAIN (E) STEEL BEAM • TO REMAIN )" THICK GLAZING - TEMPERED BUTT GLAZED AT VERTICALS (E) STEEL COLUMN TO REMAIN DOOR HARDWARE - SEE SCHEDULE (E) FLOORING TO REMAIN ENTRY WALL SECTION 1/2" = 1'-0" STONE BASE - OWNER FURNISHED, CONTRACTOR INSTALLED (E))i" REVEAL TO REMAIN STONE 13A8E - REPLACE AS REQUIRED. AT NEUTRAL PIER )6" ALUM. REVEAL MALL STOREFRONT FRAM - ALIGN TO LEASE LINE TENANT STOREFRONT MALL COMMON AREA • • •MS• • • M.= • • •■■• • • •11•••, ) THICK GLAZING - TEMPERED -BUTT GLAZED (E) METAL STUD AND GLUES TENANT DEMISING WALL +/- 4V-1 3/4" +/- 12'-3 1/4" OUTLINE CV SOFFIT ABOVE H •■•••■••••■■•••■■••••••• (E) GWE3 PROVIDE LEVEL 4 FINISH CONCRETE FLOOR TO REMAIN • 4■I • ••••■ IMMM • • •■•• • =M. • • OM. • • 1•••• ••■•• dn.= ••••• ■••■•■ LEASE LINE ••■ • • .■ • CONTRACTOR SHALL INSTALL VACANT TENANT • GWE3 AT WALL AS REQUIRED SPACE TO FINISH SHEATHING AND PAINT TO LEVEL 4 FINISH 100 H (E) GUJ15 - PROVIDE LEVEL 4 FINISH +/- 4'-6 1/2" +/- 3'-5" (E) ELECTRICAL PANEL • RE: ELECT. (E) DOOR TO REMAIN 6 (E) STOCK ROOM 101 NO WOW IN (E) STOCK ROOM LEASE LINE • •••••••••••■••••■•••■•••••■■■••• • .4•••• ••••• • • Min. • • ••••• • • MOM • LEASE LINE 60-10" .•M•• • • Olm•PI • • ••••I, MOM OWNS • • 11•1••• • • ■■• • • ■■■ 0 NORTH , FLOOR PLAN 1 4" = 11-0" DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK . DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB THRESH 100 COMMON MALL - RETAIL AREA N/A GLASS PR 3'-0" X I0'-0' 1/2" GLASS N/A WA NR. 2,3 2,3 2,3 1 2, 3, 4, 5 101 RETAIL AREA - STOCK ROOM EXISTING 31•0" x11-0" N.R 1 102 STOCK ROOM - CORRIDOR EXISTING 3'.0" x T-0" I HR REMARKS 1. EXISTING DOORS ARE TO REMAIN - NO MODIFICATIONS TO DOORS OR PRAMS 2: FUR4I51-1 MD INSTALL TILE TO MALL CONCOURSE TILE TO LEASE LINE 3. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS MEETING ALL REQUIREMENTS FOR GLASS DOORS INCLUDED 'ADJACENT !BORROWED LITES. 4- PULLS TO BE STAINLESS STEEL 5. DOORS TO HAVE SIGN (1" HIGH LETTERS) LOCATED ABOVE DOORS UJINN VACANT SPACE STATING "THIS 1 DOOR TO REMAIN UNLOCKED 11,1-1EN /WILDING IS OCCUPIED' ---,-- — - - - , ___ ABBREVIATIONS AL FL FR HM NR STOR wr) ALUMINUM FLUSH DOOR FRAME HOLLOW METAL NON-RATED STOREFRONT DOOR WOOD (E) ADJACENT TENANT STOREFRONT TO REMAIN (E) TENANT DEMISING WALL TO REMAIN LEASE LINE PROVIDE LEVEL 4 FINISH TO (E) GUJI3 WALL NEUTRAL PIER DETAIL 1 1/2" = 1'-0" HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER (CRL) 2 PRS. 1" DIA. 1S" BACK TO BACK PULLS (CRL GLASS MOUNTED STRAIGI-4T) 2 QTY. DEAD BOLT FLOOR RAIL LOCK (CRL DOOR FLOOR RAIL LOCK) 2 QTY. CYLINDER (CRL MORTISE KEYED CYLINDER) FINIS-4 OF HARDWARE AND 81ILES SHALL BE BRUSHED STAINLESS STEEL STOREFRONT FRAME - ALIGN WITH LEASE L INE ij Ni DEMO (E) GRANITE RILL HEIGHT OF NEUTRAL PIER STONE 13ASE - OFCI GLASS DOOR RE: SCHEDULE G11.43 AND METAL STUD FRAMING AS REQUIRED, LEVEL 4 FINISH /PROVIDE LEVEL 4 FINISH TO (E) GUS WALL ••••••••••••••••■■■•••■■•••••••• .www • ■■■ (E) TENANT DEMISING WALL TO REMAIN LEASE LINE ADJACENT STOREFRONT TO REMAIN NEUTRAL PIER DETAIL 1 1/2" = MALL STOREFRONT STOREFRONT DESCRIPTION - EXTRUDED SADDLE TYPE FRAME AT JAMBS 4 1/2" WIDE JAMBS - EXTRUDED SADDLE TYPE FRAME AT HORIZONTAL MULLIONS, SILL AND HEAD - SILL SHALL BE 6)i" HIGH - MULLION SHALL BE 4 1/2" HIGH - SHALL BE 4 1/2" - FRAME FINISH SHALL 15E BRUSHED STAINLESS STEEL - VERTICAL JOINTS IN STOREFRONT SHALL 15E )6" WIDE MAXIMUM BUTT GLAZED SYSTEM • (E) CEILING AT MALL CONCOURSE BREAK MET AL SHAPE AT HEAD - MATCH STOREFRONT FRAMING STOREFRONT FRAME - ALIGN WITH LEASE LINE )i THICK GLAZING - TEMPERED -E3UTT GLAZED 1' 2" FIELD VERIFY BULK HEAD DETAIL 1 1/2" = 1'-0" (E) METAL STUD FRAMING METAL STUD FRAMING AND GLIB (E) STRUCT. STEEL BEAM AND COLUMN (E) METAL STUD AND GWE3 TENANT DEMISING WALL (E) DOOR TO REMAIN (E) METAL STUD AND GLUE) TENANT EM IS ING WALL NOTES: I. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR 61-IALL VERIFY EXISTING MD NEW DIMENSIONS AND NOTIFY ARCHITECT OF ?Ni' DISCREPANCIES. 2. WALL TYPES SHALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS NOTED OTHERWISE IN WALL TYPES. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAN- LEAVING MN. 6" GAP AT TOF OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL f3E SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PEWIT. 5. ALL MATERIALS SHALL BE NON-COMISUSTIBLE AND/OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO .4NY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 6. CONTRACTOR 51-IALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION ANY DESCREFENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION'. 1. CONTRACTOR 51-IALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WOIRK, OR DUST 64-IALL ENTER OR BE WITHIN MALL COMMON AREA • REVIEWED FOR CODE COMPLIANCE APPROVED • OCT 27 2011 City of Tukwila BUILDING DIVISION et)1144/410332. ci4094j1E(atiLA OCT 1 1 2011 PERMITCENTER sde South cen ter WA., 55188-286 206-248-0423 WESTFIELD DESIGN & _ CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025-1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS M INSTRUMENT Cf SEFACE, IS THE PROPERTY or tHE ARCHITECT AND MAY NOT BE REPRODUCED VADICUT THE ARCHITECTS PERMISSION MO UNLESS ME REPRODUCRON CARRIES THE ARCHITECTS NAME AIL DESCH AND OTHER INFORMATION SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY ANO SHALL NOT BE USED OTHERWISE WITHOUT MUTTER PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (208) 824-2777 • FAX (200 824-2973 TENANT STOREFRONT IMPROVEMENTS ISSUE rvCO Ln —co ;5 Z3) C.) < F— D < 0 c0 c0 (3) ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN WALL SECTION ELEVATION AND DETAILS Al .0 SMSA #1022.10