Loading...
HomeMy WebLinkAboutPermit D11-350 - UPLAND BUILDING 1 - REROOFUPLAND BUILDING 1 1127 ANDOVER PK W Dl 1 -350 City okukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049102 Address: 1127 ANDOVER PK W TUKW Suite No: Project Name: UPLAND BUILDING 1 DEVELOPMENT PERMIT Permit Number: D11 -350 Issue Date: 11/15/2011 Permit Expires On: 05/13/2012 Owner: Name: AMB PROPERTY CORP Address: 60 STATE ST STE 1200 C/O RE TAX , BOSTON MA 02109 Contact Person: Name: JENNIFER WRIGHT Address: PO BOX 9339 , TACOMA WA 98490 Contractor: Name: WRIGHT ROOFING INC Address: 6035 S ADAMS , TACOMA WA 98409 Contractor License No: WRIGHRI174QZ Phone: 253 - 472 -3321 Phone: 253 - 472 -3321 Expiration Date: 11/05/2013 DESCRIPTION OF WORK: REMOVE EXISTING ROOFING DOWN TO VAPOR BARRIER, INSTALL NEW 1/2" COVER BOARD MECHANICALLY ATTACHED, INSTALL IN HOT ASPHALT (1) BASE SHEET, (2) PLY SHEETS & (1) GRANULATED CAP SHEET. Value of Construction: $365,240.00 Type of Fire Protection: Type of Construction: Electrical Service Provided by: PUGET SOUND ENERGY Fees Collected: $6,054.06 International Building Code Edition: 2009 Occupancy per IBC: * *continued on next page ** doc: IBC -7/10 D11-350 Printed: 11 -15 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied N Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pre . s• - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance o work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: i i i �� Date: ' j l ) S 1(1 Print Name: Vi This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary doc: IBC -7/10 D11-350 Printed: 11 -15 -2011 sewer connections, and properly fill or otheigke protect all basements, cellars, septic tank -lls, and other excavations. Final inspection approval will termined by the building inspector based tisfactory completion of this requirement. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: Application of roof coverings with the use of an open -flame device or a propane - fueled asphalt tank/kettle requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi - purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 14: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 15: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -350 Printed: 11 -15 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 SouthcenterBlvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.pov B ik P ui Ing errant No.ti4 �' U Mechanical hermit No. Plumbing /Gas Permit No. Public Works Permit No. Project No. (F" r °Pce use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** TE LOCATION King Co Assessor's Tax No.: 352304 -9102 Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No Site Address: '725-1139 Andover Park West Tenant Name: Upland Building 1 Property Owners Name: Prologis, L.P. Mailing Address: 12720 Gateway Drive, #110 Tukwila City State 98188 Zip CONTAC ON who t1 contact whe our perm ready t e issued Name: Wright Roofing,Inc. - Jennifer Wright Mailing Address: PO Box 9339, Tacoma, WA 98490 E -Mail Address: wrightroofing @msn.com Day Telephone: (253) 472 -3321 City State Fax Number: (253) 474 -5423 Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Elumbing and G pg 5)) Company Name: Wright Roofing, Inc. Mailing Address: PO Box 9339, Tacoma, WA 98490 Contact Person: Jennifer Wright, Vice President E -Mail Address: wrightroofing @msn.com Contractor Registration Number: WRIGHRI174QZ City State Day Telephone: (253) 472 -3321 Fax Number: (253) 474 -5423 Expiration Date: 11/05/2013 Zip ARCIfit' ECT OF RECORD Alt plans must be stamped by Architect of Record Company Name: N/A Mailing Address: State Contact Person: E -Mail Address: City Day Telephone: Fax Number: Zip ENGINEER OF RECOR All plans mu t be stamped by Engineer of Record Company Name: N/A Mailing Address: Zip Contact Person: E -Mail Address: H: \Applications \Farms - Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised. 7 -2010 bh City Day Telephone: Fax Number: State Page 1 of 6 S.‘Y BUILDING` PERMIT INFORMATION —206,401- 670 Valuation of Project (contractor's bid price): $ 365,240.00 Existing Building Valuation: $ Scope of Work (please provide detailed information): Remove existing roofing down to vapor barrier, install new 1/2" coverboard mechanically attached, install in hot asphalt (1) base sheet, (2) ply sheets & (1) granulated cap sheet Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. wide 11 Building Are n Square Footage Below' 1 °(Floor Interior Remod+ Addition to Existing Structure Type of Construction per IBC Type of Occupancy per 2 " Floor 3rd Floor' Floors Bas+ AcceSSot Attached oars Detached G Detached Carpet) Covered De Uncov PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H: \ApplicationsTorms- Applications On Line \2010 Applications \7 -2010 - Permit Application doc Revised: 7- 2010 bh Page 2 of 6 R,ERMIT4AP CATI .. W:t EkHiarka9V 4i h,Fbtd NPNO4TESA `pplicabletolall;permtts inIthts appltcat on 1 ? 'it3$i• r� Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHO Signature: Print Name: Jennifer Wr Mailing Address: PO Box ED A ENT Date: 10/25/2011 Day Telephone: 253- 472 -3321 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H:Wpplications \Forms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049102 Address: 1127 ANDOVER PK W TUKW Suite No: Applicant: UPLAND BUILDING 1 RECEIPT Permit Number: D11 -350 Status: APPROVED Applied Date: 10/25/2011 Issue Date: Receipt No.: R11 -02487 Initials: User ID: Payee: JEM 1165 Payment Amount: $3,670.90 Payment Date: 11/15/2011 11:37 AM Balance: $0.00 WRIGHT ROOFING INC, JENNIFER WRIGHT TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 003433 ACCOUNT ITEM LIST: Description 3,670.90 Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $3,670.90 3,666.40 4.50 doc: Receipt -06 Printed: 11 -15 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3523049102 Address: 1127 ANDOVER PK W TUKW Suite No: Applicant: UPLAND BUILDING RECEIPT Permit Number: D11 -350 Status: PENDING Applied Date: 10/25/2011 Issue Date: Receipt No.: R11 -02337 Initials: User ID: Payee: WER 1655 Payment Amount: $2,383.16 Payment Date: 10/25/2011 02:21 PM Balance: $3,670.90 JENNIFER WRIGHT TRANSACTION LIST: Type Method Descriptio Amount • Payment Credit Crd VISA Authorization No. 001167 ACCOUNT ITEM LIST: Description 2,383.16 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 2,383.16 Total: $2,383.16 doc: Receiot -06 Printed: 10 -25 -2011 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 a' (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 b/ /.-3 Project: ,..„ 2' //.L la ,./J s z i ,„ 4„ /n/ 6 of Inspection: .i 1 It.iil Lr Address: , /427 /awl) cc' PK 0-1 Called: Special Instructions: d & y,- -S-3 - 0 / Date Wanted:. �.rcEr //' 30- /2. p.m. Requester Phone No: a 3 - /7Z.-33Z/ Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: {) `( e..)(' Date: 1 / ? 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD • Retain a copy with permit -,3S PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ,p_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ZbaLf/il.1i Type of Inspection: /3,cf- %400/: Address: /727 4 P GtJ Date Called: Special Instructions: Date Wanted:. /a- i`1 -// a.m. P' • Requester: Phone No: 0,253 -V72 3, / Approved per applicable codes. D Corrections required prior to approval. COMMENTS: (Dater -`, n REI 5 ECTION FEE REQUI D. Prior t next inspection, fee must be pa t 6300 Southcenter Blvd., Suite 10 . Call to schedule reinspection. _. • _4__ -a. — _ MapQuest Maps - Driving Directions - Map F LE COPY Permit No., b l,— ' SQ plrn review approval is subject to amore and Ana of construction documents does not authorize th^t: • aton of any adopted code or ordinance. Receipt d1 f pproved Co •■ and conditions Is a is owIedged: City Of ltdcwila Vis BUILDING DIVISION SEPARATE PERMIT REQUIREDf rise content, road condiitto��'or L ilechanic aJ C?'Etectrical 'Plumbing ioras Piping •f Tukwila isiori Triibnd Dr Page 2 of 2 I 135-1 139 wvki0Ve/ Par le w 35a3o� - ci t 02 COD COMPLIANCE A PPRO °.` D NOV 0 9 2011 City of Tukwila BUILDING DIVISION a 3 3 REVISION N©ichanges shall be made to the scope 3 of work without prior a'pprovai of Tukwila Building Division. ::f )T7: risvisions will require a view plan submittal and may include additional ptan review fees. _ _S 18 f)t h St ©2011 MapQuest c3 Portic is (412011-7NAVIEQ, Intermap I�Ierms f directions and maps is subject to the MapQuest Terms of Use. We make no guarantee of the accuracy of their ute usability. You assume all risk of use. View Terms of Use 3s0 ECE VEF OCT 25 a� http: / /www.mapquest.com /print ?a= app.core.b4657a 17d2f7d589243267dd TCENTEF 10/25/2011 LEGEND: ® SKYLIGHT / SMOKE VENT IN ROOF HATCH HVAG UNITS © HEATER VENT • GRAVITY VENT o SOIL VENT • ROOF JACK • PITCH PAN ▪ THROUGH WALL SCUPPER KEY NOTES z5-- DETAIL NLMI3 J DETAIL REFERENCE - DETAIL NLMBER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 9 2Q11 City of Tukwhz BUILDING D ;V;S;ON: KEY NOTES 1. TAPERED EDGE STRIPS TO FORM SUMP AT THROL11-1 WALL SGLPPERS. SEAL RELIEF GUTS IN GAP SHEET SL/RFAGE WIT-11 J'vl PERMAFLASH SYSTEM AND GOAT WITH ALLMIN,M ROOF COATING. 2. ONE —EIGHTH PER FT FACTORY TAPERED RIGID' INSLLAr10N BELOW RECOVER BD. 3. NEW SGLPPER SLEEVE AND GGLL EGTOR HEAD PER PETAL No. '02 "" (E) D.S. TO REMAIN. 4. NEW PREFINIS 1EP METAL COPING OVER ICE All) WATER DAM PROTECTION MEMBRANE PER PETALS No. "01„ & '04 ". 5. RETROFIT (E) ROOF HATCH OVER NEW STACKED NAILERS THAT MATA-1' THE THICKNESS OF THE RIGID INSLLATION CRICKETS. SECURE AND FLASH PER PETAL DRAWING ' "Il "" REPLACE (E) SAFTEY RAIL AROUND ROOF HATCH WITH (N) KEEHATGH RHSR —SS MAN,FAGTLRED PY THE SAFETY RAIL Sa,RGE, INC., [1TTP: / /SAFETYRAILSOLARGE.GGM] AND PROVIDE 'LADDER LP SAFETY POST BY BILGO CORP. (HTTP: //BILGO.GGM] 0. CRICKETS ON HIGH SIDE OF ALL CURBS (TYP.) 7. ADD ALTERNATE: REPLACE SMOKE VENT' LNIT WITH (N) SIJIWAVE UNIT BY FBPGo • FURNISH AND INSTALL WOOD BLOCKING AT ALL GALVANIZED STFFI ROOF JACKS PER PETAIL DRAWINGS. LEAD JACKS DO NOT REQUIRE BLOCKING. 9 PROVIDE (N) P.T. OR REDWOOD SLEEPERS OVER PROTECTION PAD FOR PIPE SUPPORTS PER PETAL No. "09 "" 10 REPAIR OR REPLACE BENT METAL GAP BELOW HVAG UNIT Il. GLEAN AND PAINT RUSTED VENT STACKS WITH RLSTOLEUM ALLMINLM PAINT. 12. REPLACE PLYWOOD DECK PANEL() AND STRINGERS AT PONDING AREAS: REBUILD ROOF WITH BASE SHEET, FILLER BOARD, RECOVER BD. AND (N) MEMBRANE AS SPEG17. REPLACE UNDERSIDE F.G. INSULATION (IF REQUIRED). ESTIMATE 192 S.F. 13. TAPERED EDGE STRIP (O" TO 1/2) X /2" AT PERIMETER PER PETAIL No. "01 "" FURNISH AND INSTALL EXTRA PLY FELT WITHIN 5 -0"OF THE ROOF PERIMETER. 14. REPLACE (E) STORM GAPS ON HEATER VENT STACKS WITH (N) ALUM. GAPS TO MATCH EXISTING. DESIGN PARAMETERS GORE— INTERNATIONAL BUILDING GODS 2009 WIND DESIGN: 90 MPH /3 SECOND PEAK GUST &ROUND ROUGHNESS FIRE RESISTANCE, UL. GLASS A. MFR'S GUARANTEE` 20 YEAR NDL Permit No DESCRIPTION OF NEW ROOF: REMOVE AND DISPOSE OF (E) GAP SHEET BUR, CANT STRIPS, RELATED FLASHINGS, AND (E) Il /IG " F.G. INSLLATION DOWN TO (E)' VAPOR RETARDER. OVER (E) VAPOR RETARDER, FURNISH AND INSTALL A (N) SINGLE LAYER, OF 1/2" RETROFIT BD. MECHANICALLY' FASTENED, ONE PLY OF NON — POROUS 15,45E SHEET, Z PLIES GF TYPE IV F.G. FELTS AND AI WHITE F.G. GAP SHEET ADHERED WITH' HOT' ASPHALT. FURNISH AND INSTALL RELATED FL' A ZINGS AT G{JRP6, WALL AND PENETRATIONS TO COMPLY WITH MFRS 20 YR. GUARANTEE REQUIREMENTS. PROVIDE A MAN,FAGTLRERS 10' YEAR NDL WATERTIGHT ROOF' GUARANTEE.. csl 0 e ®I cfm blt3so RECEIVED OCT 25 2011 P ;':.i: TCENTEF SHEET NO. R -1 DRAWN BY: R. BURKE CHECK BY N. LOVATO BRENT TITLE ROOF PLAN SHEET SIZE B SCALE 1' = 80' Upland Distribution Center (Bldg 293) 1125 -1139 Andover Park West Tukwila, Washington 98188 FOR: PROLOGIS Denver, Colorado, CyberCon Consulting Inc. oofing and Waterproofing Consultants P.O. Box 621832 Littleton, Colorado (17111r 80162 -1832 6482 South Quebec St., Bldg. 3 Centennial, Colorado 80111 TEL.: (303) 741 -6020 DOCUMENT RECORD DATE GD 8 -25-11 2 ADDENDUM #I S -20-11 1A 1 r (0) D� ' N INC. Written Narrative Site Address: 1125 -1139 Andover Park West King Co Assessor's Tax No: 352304 -9102 Existing roof is comprised of a 4 -ply built -up roof system over a 1/2 coverboard over a vapor retarder comprised of (2) glass ply sheets and an asphalt flood coat. The new roof system is a 4 -ply built -up roof comprised of a'I/" coverboard mechanically attached with screws and plates per Mfg standard fastening patterns. Install 1 -ply of fiberglass base sheet, 2 -plies of glass ply sheets, and 1- granular surfaced cap sheet in hot asphalt per Mfg standard installation practices. � •. , `; ` ■cr c- NOV 0 0 2011 • ft- 3 Con. No. WR- IG -HR -I- 174 -QZ 6035 S. Adams PO. Box 9339 Tacoma, WA 98490 Office (253) 472 -3321 1- 800 - 533 -0310 FAX (253) 474 -5423 RECEIVED OCT 25 2011 TER Johns Manville FILE COPY Permit N ®• °UR Asphalt - Applied Specifications; 4GNC NOV 0 9 2011 • Four -Ply Mineral- Surfaced Fiber Glass Built -Up Roof. For use over wood or other nailable decks on inclines of up to G" per ft (500 mm /m). Materials per 100 ft' (9.29 m2) of roof area Sheathing Paper. Wood board decks only 1 layer Felts: (Gla'sBase RILTss,+t 1 ply GI isPly IV dies (GlasKap !'DI Asphalt (Interply): Trumbull®" or other JM- approved asphalt Incline per foot Asphalt Nominal Weight Up to 1" (83 mm /m) 170 °F (77 °C), Type 11, Flat 69 Ib (31 kg) 1" to 3" (83 to 250 mm /m) 190 °F (88 °C), Type III, Steep 69 Ib (31 kg) 3" to 6" (250 to 500 mm /m) 220 °F (104 °C), Type IV, Special Steep 69 Ib (31 kg) Up to 6" (500 mm/m) PermaMop 69 lb (31 kg) Approximate installed weight: 175 - 260 Ib (79.4 - 117.9 kg(. General This specification is for use over any type of approved structural deck (without insulation) which can receive and adequately retain nails or other types of mechanical fasteners that may be recommended by the deck manufacturer. Examples of such decks are wood and plywood. This speci- fication is not for use directly over lightweight, insulating concrete decks. Design and installation of the deck and /or substrate must result in the roof draining freely and to outlets numerous enough and so located as to remove water promptly and completely. Areas where water ponds for more than 24 hours are unacceptable and are not eligible to receive a JM Peak Advantage Guarantee. Note: All general instructions contained in the current JM Commercial/ Industrial Roofing Systems Manual should be considered part of this specification. Flashings Flashing details can be found in Section 3 of the JM Commercial /Industrial Roofing Systems Manual. Application Over wood board decks, one ply of sheathing paper must be used under the base felt and on top of the wood board deck. Note: On roof decks with slopes up to 1" per ft (83 mm /m), the roofing felts may be installed either perpendicular or parallel to the roof incline. On slopes over 1" per ft (83.3 mm/m), refer to Paragraph 11.0 of Section 3b for special requirements. Using GlasBase Plus, PermaPly 28 or Ventsulation Felt, start with a 12" (305 mm) width (a specific base sheet may be a condition of Guarantee(. The following base sheet courses are to be applied full width, lapping the preceding felt 2" (51 mm) on the side laps and 4'1102 mm) on the end laps. Nail the side laps 9" (229 mm) o.c. Down the longitudinal center of each felt, place two rows of nails spaced approximately 11" (279 mm) apart, with the nails staggered on approximately 18" (457 mm) centers. Use nails or fasteners appropriate to the type of deck with 1" (25 mm) minimum diameter caps. tokk--35r) City of Tukry �9e Nailable Deck Sheathing Paper (If Required) GlasBase Plus, PermaPly 28 or Ventsulation Felt uU.O!NC gE-+aVIS.'Ot Asphalt- GlasKap Mineral - Surfaced Cap Sheet 4GNC GlasPly Premier or GlasPly IV 2" Lap 1 4" End Lap �— For additional fastener information, refer to the "Roof Deck" section of the current JM Commercial /Industrial Roofing Systems Manual. Using GlasPly Premier or GlasPly IV, apply a piece 18" (457 mm) wide, then over that, a full width piece. The following felts are to be applied full width overlapping the preceding felts by 19" (483 mm) so that at least 2 plies of felt cover the base felt/substrate at all locations. Install each felt so that it is firmly and uniformly set, without voids, into the hot asphalt (within ±25 °F [±14 °C] of the EVT) applied just before the felt at a nominal rate of 23 lb/100 ft2 (11 kg/9.29 m2) over the entire surface. Surfacing Prior to application of GlasKap, cut the cap sheet into handleable lengths (12' - 18' 13.66 m - 5.50 m)(. Lay the material out on the roof and allow it to relax and flatten. To accommodate a full width sheet, apply a mopping of hot asphalt, approximately 20 °F (11 °C) above the EVT, at a nominal rate of 23 lb /100 ft2 (11 kg/9.29 m2(. (The higher temperature of asphalt maximizes the bonding of the cap sheet to the ply felts.) Then flop the cap sheet into the hot asphalt On subsequent courses, the cap sheet is positioned upside down, directly over the sheet in the preceding course such that the side lap area of the preceding sheet is exposed. Care should be taken to maintain 2" (51 mm) side laps and 4" (102 mm) end laps. Asphalt is applied in the same manner as before, making sure to also cover the 2" (51 mm) exposed side lap. Asphalt may also be applied to the exposed "upside down" cap sheet, prior to "flopping" it into the hot asphalt The cap sheet must be firmly and uniformly set, without voids, into the hot asphalt with all edges and laps well sealed. tap, Asphalt Asphalt should meet the requirements of ASTM D 312. JM guarantees require the use of Trumbull®" asphalt or a JM- approved asphalt. LI OCT 25 2011 ..t •:f�.l li (J l... Check with a JM Technical Services Specialist for special asphalt requirements in hot climates. Note: For the most current information on general guidelines, please refer to the System Considerations tab under Systems Introduction & Selection on the JM Roofing Web site. For specifications, flashing details and general installation information please refer to the System Application tab. "Trumbull is a registered trademark of Owens Corning. Refer to the Material Safety Data Sheet and product label prior to using this product. RS -2049 5 -11 (Replaces 5 -10) TGFU.R10167 - Roofing Systems FILE COPY TGFU.R10167 Roofing Systems Page Bottom Roofing Systems See General Information for Roofing Systems JOHNS MANVILLE 717 17TH ST DENVER, CO 80202 USA R10167 Page 1 of 5 CODE CCMPL ANCE NOV 0 9 2011 City of Tukviine BUiLD!NG DIV!SEON 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® or 1/4 in. thick (min) United States Gypsum Co. SECUROCK'" Glass -Mat Roof Board (Type SGMRX) may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board or overlayment board are offset 6 in. with the joints in the deck. If polystyrene insulation is used in the existing noncombustible deck Classification, it must be placed beneath the gypsum board or DensDeck®. "DuraFoam" may be used in lieu of "Fesco- Foam" applicable Classifications. " Fesco HD" is a suitable alternate to "Duraboard" in any applicable Classification. "RetroPlus" is an acceptable alternate to "Retro -Fit" or "ENRGY 3" in any applicable Classification. ECEWEC OCT 2 5 2011 r il! Any of the following insulations may be used in lieu of "ENRGY 3" in any applicable Classification: 'Tapered ENRGY 3 ", "EN G' psi ", apered ENRGY 3 25 psi ", "ENRGY 3 AGF ", "Tapered ENRGY 3 AGF ", "ENRGY 3 25 psi AGF ", "Tapered ENRGY 3 25 psi AGF ", "ENRGY 3 CGF ", "Tapered ENRGY 3 CGF ", "ENRGY 3 25 psi CGF ", 'Tapered ENRGY 3 25 psi CGF ", "ISO -3 ", "Tapered ISO -3 ", "ENRGY 3 Foil Faced ", "Tapered ENRGY 3 Foil Faced ", "AP Foil Faced Sheathing ", "Tapered AP Foil Faced Sheathing ", "ValuTherm ", "Tapered ValuTherm ", "ValuTherm 25 psi ", "Tapered ValuTherm 25 psi ", "ValuTherm AGF ", "Tapered ValuTherm AGF ", "ValuTherm 25 psi AGF ", "Tapered ValuTherm 25 psi AGF ", "ValuTherm CGF ", "Tapered ValuTherm CGF ", "ValuTherm 25 psi CGF ", "Tapered ValuTherm 25 psi CGF ". "InvinsaFoam" or "Tapered InvinsaFoam" may be used in lieu of the combination of "Invinsa Roof Board" and "ENRGY 3" in any Classified system where "Invinsa Roof Board" is directly over "ENRGY 3 ". "Urethane Insulation Adhesive" may be used to adhere insulation in any of the following Classifications. Base sheets and ply sheets may be adhered with hot asphalt (15 -25 Ib /sq) or "BUR Adhesive ", applied at 1 to 2 gal /sq. unless otherwise specified adhesive may be applied by brush, roller, notched squeegee or spray equipment. Vapor barriers or ply sheets are optional beneath roof insulation on all systems. b1I3so http : / /database.ul.com /cgi- bin/XYV /template /LISEXT/ 1 FRAME /showpag... 10/25/2011 TGFU.R10167 - Roofing Systems Page 2 of 5 r � Unless otherwise indicated, 7/16 in. (min) thick non - veneer APA rated oriented strand board may be substituted for wood fiberboard in the following systems. Unless otherwise indicated, wood fiberboard may be substituted for polyisocyanurate insulation in any of the following non - combustible systems. "GlasPly IV" and "GlasPly Premier" are suitable alternates to Type G1 ply sheet. "GlasBase XT" is an acceptable alternate to "GlasBase" in all applicable Classifications. Base /Ply Sheet Listed: Acceptable Alternative DynaBase DynaBasePR* DynaMopGL 2.2 P /S* DynaMop GL 2.2 P/S QL* DynaWeld Base DynaWeld GL 2.2 P/P DynaWeld Base DynaWeld GL 2.2 P/P DynaGrip Base DynaGrip Base SD /SA DynaGrip Base SA /SD Dibiten SAS Base DynaGrip Cap Dibiten SAS Cap DynaWeld GL 2.2 P/P DynaBase HW DynaPly DynaPly Heat Welded * Limited to noncombustible roof deck Membrane Listed: Acceptable Alternative DynaLastic 180S DynaLastic 180 DynaBase PR DynaWeld PR 3.0 P/P DynaWeld 180S DynaMopGL 2.2 P/S DynaMop GL 2.2 P/S QL DynaLastic 180 DynaWeld Cap 180 http : / /database.ul.com /cgi- bin/XYV /template /LISEXT/ 1 FRAME /showpag... 10/25/2011 TGFU.R10167 - Roofing Systems Page 3 of 5 r � DynaLastic 180 FR DynaWeld Cap 180 FR DynaLastic 250 FR DynaWeld Cap 250 FR DynaLastic 250 DynaWeld Cap 250 DynaLastic 250S DynaWeld 250S DynaKap FR DynaKap FR Heat Welded Unless otherwise indicated, the term "Referenced SBS Base Sheets" will include the following: "DynaLastic 250 ", "DynaLastic 250S ", "DynaWeld Cap 250 ", "DynaWeld 250S ", "DynaKap ", "DynaPly ", "DynaPly Heat Welded ", "JM SBS 170 ", "DynaBase ", "DynaBase PR ", "DynaBase XT ", "DynaWeld Base Sheet ", "DynaWeld GL 2.2 P /P ", "DynaMop GL 2.2 P /S ", "DynaMop PR 2.2 P /S ", "DynaMop GL 2.2 P/S QL ", "DynaMop PR 2.2 P/S QL ", "DynaLastic 180 ", "DynaLastic 180S ", "DynaWeld Cap 180 ", "DynaWeld 180S ", "DynaWeld PR 3.0 P /P ", "DynaGlas ", "DynaGlas 5", "Nord Flex Duo Ply FR Base Sheet ", "JM CleanBond Base ", "Dibiten SAS Base ", "DynaGrip Base ", "DynaGrip Base SD /SA ", "DynaGrip Base SA /SD ", "DynaGrip Base SA /SA ", mechanically fastened, hot mopped or heat welded. "JM E3 Co, a Johns Manville company dedicated to emerging energy technologies ", produces the "JM E3 co PowerBlanketTM" product, a factory laminated solar blanket consisting of United Solar Ovonic LLC's Field- Assembled Photovoltaic (Solar) Module Systems "PVL -29, -31, -58, -60, -62, - 64, -68, -87, -93, -116, -120, -124, -128, -136, -144" attached to a specific UL Classified Johns Manville membrane, may be installed over any UL Classified Johns Manville BUR, SBS modified bitumen or TPO roofing system. For BUR and SBS modified bitumen systems, the Module System is adhered to a layer of "JM TPO FB" in the factory, which is then attached to the roofing membrane in the field using ribbons of MBR Bonding Adhesive, at 6 in. OC to 12 in. OC. The maximum incline and Classification (Class A, B or C) for BUR and SBS modified bitumen systems shall be in accordance with the Classification established for the membrane roofing assembly, however the incline cannot exceed 1:12. For TPO systems, the Module System is self- adhered to the roofing membrane in the field, or is attached to a layer of "3M TPO" in the factory, which is then attached to the roofing membrane in the field using heat welding. The Classification applies to combustible and non - combustible decks. The maximum incline and Classification (Class A, B or C) for TPO systems shall be in accordance with the Classification established for the membrane roofing assembly, however the incline cannot exceed 2:12." "JM Asphalt Primer" (not UL Classified) may be used to prepare the substrate in any of the following systems. ASPHALT FELT SYSTEMS WITH HOT ROOFING ASPHALT Unless otherwise specified, min insulation thicknesses shall be "Fesco" or "DuraBoard" 3/4 in., "ISO 3" 1.4 in., "ENRGY 3" 1.4 in., "Fesco- Foam" 1.5 in. min, "Fesco- Foam" 1.5 in. min placed foam side down over min 3/4 in. thick "Fesco" or "DuraBoard ", mechanically fastened to the deck, is a suitable alternate for 1.5 in. min "Fesco- Foam ". Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. The following products may be used in lieu of "ENRGY 3" or "ISO -3 ": "PSI- 25 -2 ", "Nailboard ", "ENRGY 3 Plus ", "ISO 3 Foil Faced ", "ENRGY 3 Gypsum Composite" or "Fesco- Foam ". " GlasBase Plus" is a suitable alternate to "GlasBase" or "DynaBase ". "Fiber Glass Roof Insulation" or "Laminator Board" may be used in any noncombustible deck roofing systems. Fiberglas Canada "Base Cap Roof Insulation" may be used as an alternate to "Fiber Glass Roof Insulation ". http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpag... 10/25/2011 . , TGFU.R10167 - Roofing Systems Page 4 of 5 1/2 in. thick "Invinsa Roof Board" is an acceptable alternate to 1/4 in. thick "Invinsa Roof Board ". Taped joints are optional with "Fiber Glass Roof Insulation ". "PermaMop" modified asphalt is an acceptable alternate to hot roofing asphalt in the asphalt felt built -up roofing systems. Red rosin paper must be used over combustible decks when "GlasPly IV" or "GlasPly Premier" are nailed as base sheets in asphalt membrane systems. "PermaPly 28" is a suitable alternate to "GlasBase" fiber glass base sheet. The Class A and B roof coverings are suitable for installation over min 3/4 in. thick "Fesco ", "DuraBoard" or "Fiber Glass Roof Insulation ". Min 3/4 in. thick wood fiber roof insulation is suitable any for assemblies over noncombustible decks unless otherwise specified. "GlasTite Flexible" is a suitable alternate for "DynaBase ", "GlasBase" or "PermaPly 28 ". "DynaWeld Cap FR" is suitable substitute for "DynaGlass 30 FR ". Barrett "Ram -Tough KLB -100" modified asphalt may be used in lieu of standard hot mopping asphalt in all applicable Classifications. "Roof Defender Fiber Glass Cap Sheet" is a suitable alternate to "PermaPly 28" in all applicable Classifications. " DynaGlas S " and "DynaLastic 250S" may be used in lieu of "DynaPly" in all applicable Classifications. s .q A "Class r w 1. Deleted. 2. Deck: C -15/32 Incline: 1 Insulation (Optional): — Any thickness, one or more layers "Fesco" or "DuraBoard ", " Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro -Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. Base Sheet: — One ply Type G1 or "GlasPly IV" or "GlasPly Premier ", or Type G2 "Glas- Base" or "Ventsulaton ", or "DynaBase" or "DynaGrip SD /SA" (modified bitumen), nailed or hot mopped or self- adhered. PIy Sheet: — Two or more plies Type G1 or "GlasPly IV ", "GlasPly Premier ", hot mopped. Surfacing: — Gravel, crushed stone or slag and hot roofing asphalt. 3. Deck: C -3/4 Incline: 3 Insulation (Optional): — Any thickness, one or more layers "Fesco" or "DuraBoard ", "Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro -Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. Base Sheet: — Type G2 "PermaPly 28 ", "GlasBase" or "Ventsulation" or "DynaBase" (modified bitumen), nailed or hot mopped. PIy Sheet: — Two or more plies Type G1 or "GlasPly IV ", "GlasPly Premier ", hot mopped. Surfacing: — Gravel, crushed stone or slag and hot roofing asphalt. http: // database. ul. com /cgi- bin/XYV /template/LI SEXT/ 1 FRAME /showpag... 10/25/2011 , TGFU.R10167 - Roofing Systems Page 5 of 5 4. Deck: C -3/4 Incline: 3 Insulation (Optional): — Any thickness, one or more layers "Fesco" or "DuraBoard ", "Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro -Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. Ply Sheet: — Three or more plies Type G1 or "GlasPly IV ", "GlasPly Premier ", nailed or hot mopped. Surfacing: — Gravel, crushed stone or slag and hot roofing asphalt. 5. Deck: NC Incline: 1 -1/2 Insulation (Optional): — Any thickness, one or more layers "Fesco" or "DuraBoard ", "Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro -Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. Base Sheet: — Type G2 "PermaPly 28 ", "GlasBase" or "Ventsulation" or "DynaBase" (modified bitumen), nailed or hot mopped. Surfacing: — Type G3 "GlasKap ", hot mopped. 6. Deck: NC Incline: 1 -1/2 Insulation (Optional): — Any thickness, one or more layers "Fesco" or "DuraBoard ", "Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, hot mopped or mechanically fastened in combination (optional) with 1/2 in. "Retro -Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. Ply Sheet: — Two or more plies Type G1 or "GlasPly IV ", "GlasPly Premier ", nailed or hot mopped. Surfacing: — Type G3 "GlasKap ". 7. Deck: C -15/32 Incline: 1 1.. �•6 to Insulation (Optional): — Any thickness, one or more layers of 1/2 in. "Retro- Fit ", "DuraBoard ", "Fesco" or "DuraBoard ", "Fesco- Foam ", "Fiber Glass Roof Insulation ", "ISO 3 ", "ENRGY 3" or any UL Classified polyisocyanurate insulation, in combination (optional) with 1/2 in. "Retro-Fit" cover board, or 3/4 in. "Fesco" or "DuraBoard" over polystyrene. All insulation joints offset from plywood deck joints, 6 in. min. Base Sheet: — • " - •• pe- 62 --PefnaaPly 28 ", lGI� _s� saasse2 " hot mopped. Ply Sheet: — One or more plies , rGlly Surfacing: — Type G3 "GlasKap "o hot mopped. t hot mopped. http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME/showpag... 10/25/2011 • 11 -01 -2012 JENNIFER WRIGHT PO BOX 9339 TACOMA WA 98490 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. D11 -350 UPLAND BUILDING 1 1127 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/13/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. Or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/13/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. ...._...._._.=:4to Rambo Permit Technician File: Permit File No. DI 1-350 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206-431-3665 June 6, 2012 City of f Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jennifer Wright Wright Roofing, Inc. PO Box 9339 Tacoma, WA 98490 RE: Request for Extension Development Permit No. D11 -350 Upland Building 1 -1127 Andover Pk W Dear Ms. Wright, This letter is in response to your written request for an extension to Permit Number D11-350. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration, through December 13, 2012. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. DI 1 -350 W: \Permit Center\Extension Letters\Permits\201 I \DI 1 -350 Permit Extension.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 RIGHT K DOPING INC. June 5, 2012 City of Tukwila 6300 Southcenter Boulevard, Ste #100 Tukwila, WA 98188 Re: Permit No. D11 -350 Upland Building 1 1127 Andover Pk W We need to ask for this permit to be extended; the weather this winter has delayed the completion of this project. If you have any questions or need any further information please don't hesitate to call. Sincerely, RIGHT ROOFING, INC. right e ' �sident j, N 05 2012 1 S (9— ( to — IL_ PERMIT CENTER /:666644 ,4 14'I1 Con. No. WR- IG -HR -I- 174 -QZ 6035 S. Adams PO. Box 9339 Tacoma, WA 98490 Office (253) 472 -3321 1- 800 - 533 -0310 FAX (253) 474 -5423 05 -01 -2012 JENNIFER WRIGHT PO BOX 9339 TACOMA WA 98490 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. D11 -350 UPLAND BUILDING 1 1127 ANDOVER PK W TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 06/16/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 06/16/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, -1,.1)U Bill Rambo Permit Technician File: Permit File No. DI 1 -350 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -350 PROJECT NAME: UPLAND BUILDING 1 SITE ADDRESS: 1127 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # DATE: 10 -25 -11 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT • ,f I ui ing Division Public Works A-v' Awc Are Prevention I7 Planning Division Structural Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-27 -11 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route $ Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions DUE DATE: 11-24 -11 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WRIGHT ROOFING INC UBI No. 600124445 Phone 2534723321 Status Active Address 6035 S Adams License No. WRIGHRI174QZ Suite /Apt. License Type Construction Contractor City Tacoma Effective Date 11/9/1983 State WA Expiration Date 11/5/2013 Zip 98409 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 2 Effective Ex e on Expiration Date Status WRIGHR"265LSWRIGHT ROOFING Construction Contractor Roofing Water Proofing 6/10/1974 11/5/1983 Archived Business Owner Information Name Role Effective Date Expiration Date WRIGHT, DAVE C Cancel Date 01/01/1980 Bond Amount WRIGHT, BUNNIE L 8 01/01/1980 023017522 WRIGHT, JENNIFERA Until Cancelled 01/01/1980 MARCELLE, RICK A 10/06/2011 01/01/1980 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 First National Ins Co 023017522 11/05/2011 Until Cancelled $12,000.00 10/06/2011 7 TRAVELERS CAS & SURETY CO 0815103351168 11/05/2001 Until Cancelled 11/05/2011 $12,000.0010/16 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 27 Valley Forge Ins Co 4016325322 05/06/2011 05/06/2012 $1,000,000.0004 /26/2011 25 VALLEY FORGE INS CO 4016325322 05/06/2009 05/06/2011 $1,000,000.00 05/05/2010 24 FIRST MERCURY INSURANCE CO FMWA000170 05/06/2008 05/06/2009 $1,000,000.0005 /02/2008 23 FIRST MERCURY INSURANCE FMFL001686 05/06/2007 05/06/2008 $1,000,000.00 04/10/2007 22 FNSST MERCURY FMFL000757 05/06/2005 05/06/2007 $1,000,000.00 04/04/2006 21 CONTINENTAL CASUALTY CO 2000571808 05/01/2005 05/01 /2006 $1,000,000.00 04/22/2005 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lniThbip/Print.aspx 11/15/2011