Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-353 - DELI - REROOF
DELI 345 ANDOVER PK E Dl 1 -353 City akukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0223400040 Address: 345 ANDOVER PK E TUKW Suite No: Project Name: DELI DEVELOPMENT PERMIT Permit Number: D11 -353 Issue Date: 11/15/2011 Permit Expires On: 05/13/2012 Owner: Name: SRO PROPERTIES INC Address: 1411 4TH AVE #1315 , SEATTLE WA 98101 Contact Person: Name: PEARLLA KAESTNER Address: PO BOX 82894 , KENMOR WA 8028 Contractor: Name: ASSOCIATED ROOFING INC Address: PO BOX 82894 , KENMORE, WA 98028 Contractor License No: ASSOCRI16206 Phone: 206 364 -4448 Phone: Expiration Date: 05/06/2012 DESCRIPTION OF WORK: WORK TO EXCLUDE FORMER SKARBOS: TEAR OFF EXISTING ROOFING AND INSTALL 1/2" COVERBOARD, 28 LB BASE SHEET MECHANICALLY ATTACHED. INSTALLATION OF MODIFIED BITUMEN GRANULAR SURFACED ROOF SYSTEM. Value of Construction: $26,730.00 Fees Collected: $1,018.34 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11 -353 Printed: 11 -15 -2011 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: { 1 K' L l I hereby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. � I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Pcctif min/ wiwr Date: )50( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDI'I'fONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IBC -7/10 D11 -353 Printed: 11 -15 -2011 7: Prior to final inspection for this building nit, a copy of the roof membrane manufactuS warranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Application of roof coverings with the use of an open -flame devices requires a separate permit from the Tukwila Fire Department located at 444 Andover Park East, Tukwila, Washington, 98188; telephone - (206)575 -4407. There shall be not less than one multi- purpose portable fire extinguisher with a minimum 2 -A 20 -B:C rating on the roof being covered or repaired. (IFC 105.6.24, 1417.3) 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 13: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 14: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11-353 Printed: 11 -15 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www. TukwilaWA. qov ck 11MAot- wc5-011/Ma Building Permit No. Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION ? /� rn �� f� King Co Assessor's Tax No.: O ZZ 3 4 U- no `( L7 Site Address: 315 AIVt .. ` o-kisE uite Number: Floor: j� (C 2W'(t 5^ A r ' Tenant Name: -V��� n� ���'nErc> � S> New Tenant: ❑ Yes � ..No Property Owners Name: , f� f t 1`" r CY -(%!"i ES c Mailing Address: 1 `t' 1 1C4‘ Ave, d I3 &5 �?`ca e City Stat �jg e Zip col CONTACT PERSON — who do we contact when your permit is ready to be issued Name:_°LLr (GE— Tej(lephoneAW o L6g- YY4 Mailing Address: 0 e'2-COP girt 2--gi E -Mail Address4 r &(& Q 42-)ex/ ,Q ? 7PIE. C4fax Numbers O 6 6 () -0Ud 3 ty State Zip GENERAL CONTRACTOR INFORMATION — (Contractor Informa'on for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) A--1' lo'l'l 1'1 Company Name: Mailing Address: Contact Perso 0 L. E -Mail Address: r C4 IA ti a aCCrA7r or II, gRAI d Contractor Registration Number: /Q . 0(2J_ 1 In 2(, ltr Day Telephone: 2% 36 I( gq4i6 C Number: Z© 36 p' SCI-5 Expiration Date: ( C ( 2& / Z • Zip 42r ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: f\- City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: ,, Mailing Address: Contact Person: City Day Telephone: E -Mail Address: Fax Number: State Zip H:\Applica bons \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATIO1 '— 206 -431 -3670 / 2 dtJ Valuation of Project (contractor's bid price): $ e 6 t '7 30 ` Existing Building Valuation: $ g--11.1 u 1 Scope of Work (please provide detaile4 information) l 4# £ E eik?e- f`]Yl5 , 2 (9jCl1 1," C uelr b 02r/4. b Surma '' R&.(_96 s?e3/ Will there be new rack storage? ❑ Yes /‘.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: 1\( Pc Single family building footprint (area of the foundation o all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No 1f "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H :\Applications\Fonns-Applications On Line \2010 Application0-2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure . New Type of Construction per IBC Type of Occupancy per IBC 1' Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: 1\( Pc Single family building footprint (area of the foundation o all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No 1f "yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H :\Applications\Fonns-Applications On Line \2010 Application0-2010 - Permit Application.doc Revised: 7 -2010 bh Page 2 of 6 • • PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NER OR AUTHORIZED AGENT: Signature: JA/1/.1 ( ��,[/�/� Mil// Print Name: Pj4rUk/ l( A I vtik- Mailing Address: Pin, , £ ,2 8 / Date Application Accepted: Date: l0 /iV D$y Telephone: f -a) / 7iee 7,09- ./ oz9 City State Zip to 1I Date Application Expires: 09 2-1 IL State Initials: H:\Applications\Fnrns- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 • I "'q City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0223400040 Address: 345 ANDOVER PK E TUKW Suite No: Applicant: DELI RECEIPT Permit Number: D11 -353 Status: APPROVED Applied Date: 10/27/2011 Issue Date: Receipt No.: R11 -02481 Initials: JEM User ID: 1165 Payment Amount: $618.95 Payment Date: 11/15/2011 10:00 AM Balance: $0.00 Payee: ASSOCIATED ROOFING INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 93085 618.95 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $618.95 614.45 4.50 doc: Receipt -06 Printed: 11 -15 -2011 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0223400040 Address: 345 ANDOVER PK E TUKW Suite No: Applicant: DELI RECEIPT Permit Number: D11 -353 Status: PENDING Applied Date: 10/27/2011 Issue Date: Receipt No.: R11 -02347 Payment Amount: $399.39 Initials: JEM Payment Date: 10/27/2011 09:55 AM User ID: 1165 Balance: $618.95 Payee: ASSOCIATED ROOFING INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 92945 399.39 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 399.39 Total: $399.39 doc: Receiot -06 Printed: 10 -27 -2011 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12. (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 0 Project: DELI Type of Inspection: r= .In,'G 1 Address: / .2'/ c � de 7 Ade4.0- s r71 e- Date Called: Special Instructions: .2. U C. A'- / (9 -6 7/.7 / ?/ te/ r) 5ec6- 7 - o ( Date Wanted:. y - - /Z - /2 Vim. p.m. Req,y,ester: figdi;tA/ Phone No: .206-3 6 `i/ - 9v' /' Approved per applicable codes. Corrections required prior to approval. COMMENTS: -e jet 1 r--Dkt)te-te Inspe or. pay+ 121 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N.. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .0/ ( -33-3 6300 Southcenter Blvd., #100, Tukwila. WA 98188 b., (206) 431-3670 permit Inspection RequestAinelZar:41111451 Project: ---- in 6 L: Type-o, finspretisq: Addrifii 11- 5 Akio aalif- Date Called: Specialjnstructions: • Date Wanted: . 2 -tit ....km., p.m. Requester: Phone No: -ZOedo -344-4448 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: •i 1 eP '. 7--.): A n z.,1 in )7A-A (.--• --i-:, 1--1- 1,i `t I\ n'. G ' ...._..... 1 - InspecK:. Date: 7 tr 1• REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be "7. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ® ,Associated Roofing, Inc. OWNER: P.O. Box 82894 206 364 4445 Kenmore, WA 800 358 3119 98028 Fax 206 368 2303 PERFORMANCE AGREEMENT SRO•PROPERTIES, INC. JARIUS STRATTON 1411 FOURTH AVENUE, #1315 SEATTLE, WA 98101 MANUFACTURER AND SYSTEM INSTALLED: POLYGLASS POLYFLEX G GRANULAR SURFACED MODIFIED BITUMEN ROOF SYSTEM PROJECT AND LOCATION: DELI 345 ANDOVER PARK EAST TUKWILA, WA AREA OF ROOF INSTALLATION: 5,600 SQUARE FEET DATE OF SUBSTANTIAL COMPLETION (EFFECTIVE WARRANTY DATE): DECEMBER 14, 2011 cIr y u LA APR 1'2 2012 PERMIT CENTER For a FIVE (5) year period, from the date of substantial completion, we will inspect and make emergency repairs to leaks in the roof system within 24 to 48 hours of receipt of notice from the Owner. We will make permanent repairs and restore the affected areas. All of this work will be done without additional cost to the Owner, except if it is determined such Teaks and defects were caused by abuse, lack of roof maintenance, earthquake, lightning, hurricane, windstorm, tomado, hail storm, or other unusual natural phenomena, structural failure or failure of related work done by others. CONTRACTOR WARRANTY: FIVE (5) YEARS MANUFACTURER'S WARRANTY: POLYGLASS TEN (10) YEAR LTD MATERIAL We advise that a maintenance program be put into effect as soon as possible. A maintenance log should be maintained at all times. A semi - annual inspection would be the minimum that we recommend. This inspection should include, but not limited to, a thorough inspection of all copings, counterflashings, caulk joints, roof membrane, as well as cleaning of gutters, drains, downspouts, and roof areas. Maintenance is not only essential, but is required to maintain the integrity of your investment for the long term. As part of this warranty, implied or otherwise stated, it is the owner's responsibility to perform the periodic inspection during the warranty period and thereafter. Penetrations to the roof cannot be made without prior approval from Associated Roofing or the roofing system manufacturer during their respective warranty period. CONTRACTO-• SSOCIATED BY : �% ' ST ''' TITL . RESIDENT DATE EXECUTED: 12 -/ '- I G, INC. Serving the Pacific Northwest since 1979 W.11 EIPIdmFIS■ Y,i i Ek1.0 AND iS fi'i.i -1 >G it STEMS a m o u r Owner's Name: 12 Year (10 Year Non - Coated)* LIMITED ROOFING MATERIAL WARRANTY ('Warranty Is self-executed by user) .S2o Owner's Address: I y' /( l floe e( g i..�1 LA-1/31 J Y 1 p City: S� �']y� State: C Zip: 1 316_1 Building Name: '! L am/ — L/ Building Address: T C // //DOI/EA fr,i9/e-K n City: -(.t %C Gi� 1 LA 'State: /if' % zip: ge%�d' Roofing Contractor Name: ,�) �� � ©p �!�ci �NC Roofing Con or Address: v - iY 62c'i 9y City: % State: GC.I 9% Zip: Roofing Contractor Phone t'n-26; 9 - %5P/.S . Polyglass Registered Contractor #: Polyglass Product(s) Used: Project Size: 5r 6 CO Square Feet Completion Date: Roofing Specification Used: 6206 CO /a Pd?Tb% TERMS AND CONDITIONS: Definitions: ' Polyglass' shall mean Polyglass° U.S.A, Inc 1111 W. Newport Center Drive; Deerfield Beach, FL 33442. 'Owner shall mean the original party listed above as Ovmer's Name whose building the Poyglass root membrane product is installed. Polyglass warrants; the Polyglass' membrane to be free from manufacturing defects wtddt affects the ebdiy of the product to perform in a watertight manner (herein considered defective) for the period of Twelve (12) years from the date of original installation of the roofing membrane for all Mineral Surfaced, Aluminum and Acrylic coated membranes, Fifteen (15) years for Emulsion/Aluminum or Emulsion/Acrylic mated, smooth surfaced membranes will be limited to Ten (10) years. This warranty is for the sole benefit of Owner described above ('Owner") and Is not transferrable or assignable. Warranty must be registered with Polyglass to become in effect otherwise the Polyglass membrane shall have warranty protection as provided by its Product LiabUity Coverage. A legible copy of this Warranty and proof of purchase must be registered with Polyglass USA, Inc, Attn: Warranty Department 1111 W. Newport Center Drive Deerfield Bead, FL 33422 within 90 days of the original date of purchase. Should Polyglass' membrane be deemed defective by Polyglass, as desalbed above, Polyglass shall exerdse the option to repair or replace such defective materials, excluding any associated labor to perform these tasks. Polyglass' maximum liability, under any circumstances, shag not exceed the 0031 Of the defective membrane at time of dais; excluding all installation related labor costs; costs of flashing, metal work, or other materials not supplied or furnished by Polyglass. This sum shall be prorated at year TWo (2) of its term, reduced by 1/12; (1/16) for EmrdsloWC.oated (1/10) for smooth surfaced; remaining in the warranty period and fuller reduced by any cost prevbusly incurred by Polyglass for the repair or replacement of any Polyglass materials wider this warranty. Any such repair or replacement to remedy leakage shall be owner's SOLE AND EXCLUSIVE REMEDY against Polyglass. Polyglass shall have no obligation based upon the following exclusions under this warranty: 1) Damage by natural disasters, inducting but not limited to lightning, halt gale force or other strong winds exceeding 8 on the Beaufort Scare, Hoods, hurricanes, tornadoes, wind launched debris, earthquakes or similar acts of god or natural causes; 2) Damage by wilful or negligent ads, fee, vandalism, or other misuse; 3) Damage by use of materials not furnished by Polyglass; 4) Owner or lessee falls to use reasonable rare in maintaining and repairing the Polyglass membrane or other required components of the roofing system. 5) Damage by structural failure, Inducting, without limitation. settling or shifting of the building, or movement, aadcing, Or deflection of the roof deck, roof substrate, roof insulation. bugling design or construction. inadequate attic ventilation; 6) Damage by any deml al condition not disclosed to Polyglass, or traffic or storage of materials Or infiltration of condensation or moisture in, through or around the walls, coping. building structure of the underlying or suncunding areas; 7) Aitarations or repairs made on or through the roof or objects (inducting, without limitation. machines. structures, fixtures, or utilities) are placed on Me roof without prior written authorization of Polyglass; 8) Metal work or other materials not furnished by Poygless and used in the roofing system resulting in leaks; 9) Poor workmanship in the application of materials as determined in Polyglass sole judgment; 10) Failure to utilize Polyglass' latest instructions and recommendations as to installation procedures; 11) Damage resulting from lack of positive, proper or adequate drainage; 12) Loss in part or in whole of granule or otter surfacing; 13) Damage or injury arising in any way from an actual or alleged discharge or release of any pollutant or waste, environmental or airhome contaminates; 14) Damage or injury arising In any way from testing/sampling of underlayment, design and consulting errors or omissions. 15) Failure to register tins warranty within 90 days of purchase to Polyglass. In addition to items 1 -15 above, owner agrees that Pdyglass shall have no responsibility whatsoever for bodily injury to any person or damage to the structure or its contents directly or indirectly arising out of any defects in its roof undedaymeM or any other consequential or incidental damages or attorneys fees. Poyglass' sole responsibility is the repair or replacement of defective underlayme0 membrane that b drectly related to leakage. This warranty does not include the cost of removal of existing, or the Cost of labor to repair or replace the defective wderiayment and/or rooting covering /systept Installed to the Polyglass underlayment. Claim Procedure: Polyglass shell have no obligation under this warranty unless Owner shag have promptly notified Polyglass in writing along with attached Proof of Purchase to Polyglass by registered or certified mail. Direct all dabs to Paygtass, U.SA Inc. 1111 W. Newport Center Drive, Deerfield Bead, Florida 33442, ATTN: Warranty Department Any claim shall provide a copy of warranty and detailed information of the leakage and alleged defect. Polyglass must receive such notice within tan (10) days after discovery of the claimed defect. - Owner shall provide Pot/glass. and its agents and employees, free, safe and reasonable access to the roof during regular business hours during Me lain of the warranty, Owner shall be responsible for all costs related to safe and reasonable access to investigate claim. Polyglass' good -faith detemdnation piths fouroe of leakage, damage. or alleged defect to the roof shall be exclusive and finding to owner. Polyglass failure at any time to enforce any of the terms and condttons of this warranty shag not be construed is a waiver of such provisions. Poygtass reserves eta fight to dmoonttnue or modify any of its products and shall not be liable to Owner as a result of any such discontinuance or modification. yy0kk G - /y— / THIS WARRANTY SUPERCEDES AND IS IN UEU OF ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABULrrY AND FITNESS FOR A PARTICULAR PURPOSE. THIS WARRANTY SHALL BE OWNER'S EXCLUSIVE REMEDY AGAINST POLYGLASS OR:.ITS AFFILIATES, AND NEITHER POLYGLASS NOR ITS AFFILIATES SHALL BE LIABLE FOR ANY CONSEQUENTIAL OR INCINDENTAL DAMAGES. POLYGLASS' AGENTS HAVE NO AUTHORITY TO GIVE WARRANTIES BEYOND THOSE PROVIDED IN THS WARRANTYALL RIGHTS AND DUTIES ARISING UNDER THIS WARRANTY SHALL BE GOVERNED BY FLORIDA LAW. Warranty presented and determined as incomplete or Inaccurate shall be considered null and void. Oeteber4011 SEPARATE PERMIT REQUIRED FOR: Tilechanical olectrical @numbing alaPs Piping fy of Tukwila DIVISION NOV 0 9 2011 I REVISIONS No changes s shall be made to the scope of work without prior approval of Tukwila Building Division. f ---- 7...::ons will require as new plan submittal . . i i i -,L'ude. additional' plan rev:ew focs FILE COPY Permit No. `15 \KJ "ity of iti:vec.. DlV!S!Oltj P frview approval is subject to ems and omissions. --vat of construction documents does not authorize tL 3!ation of any adopted code or ordinance. Receipt oqprovedFieldcopyand • 1,1 is acknowledged: v City Of Tukwila BULL:NG DIVISION ••••••••• ci4SFORA orr 27 ZOO PERMITCENTER 1 , : 1 ' i , 1 : ! • I , i 1 tV 1 <,4111111' 1-- .. =... ...... i.......1 kill ell. oill7,1..- . imeg,;•7.r.: .41 (fi . re- -11 (...) • 1" -1- ■ . , i--- 1 1 _....1 , 1 ci4SFORA orr 27 ZOO PERMITCENTER Associated Roofing, Inc. RO, Box 82894 Kenmore, WA 98028 SEPTEMBER 15, 2011 CITY OF TUKWILA DEPT OF COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD., SUITE 100 TUKWILA, WA 98188 RE: DELI SECTION 345 ANDOVER PARK EAST TUKWILA, WA ASSOCRI 16206 206 364 4445 800 358 3119 Fax 206 368 2303 FILE COPY Pennti No., The existing roofing is two 'layers Class "B" built -up asphalt roofing installed deck. Existing roofing is to be tom off. The new roof system to be installed is a Polyglass Polyflex G granular surfs heat welded /torch applied system installed over one layer of 1/2" coverboard fastened 501 modified base sheet. We have attached product literature and data for your review. RESPECTFULLY SUBMITTED, TIM RESSLER SALES ENGINEER TR /jms enc CODS NOV 0 9 2011 City of TUk fi ' IILC €WG DIVISION over a 5/8" plywood ced modified bitumen and a mechanically Serving the Pacific Northwest since 1979 It) RECEIVED CITY OF TUKWILA OCT 2 7 2011 PERMIT CENTER - ILE COPY 'Associated Roofing, Inc. ASSOCRI16206 • PROPOSAL AND CONTRACT P.O. Box 82894 This is a "plain - English" contract. "We," "us," and "our" means Kenmore, Washington 98028 Associated Roofing, Inc. "You" means the customer. 206 364 -4445 • 800 358 -3119 • 206 368 -2303 (Fax) Date: 08 -29-11 PAGE 1 OF 2 Proposal Submitted To: JARIUS STRATTON 206 -622 -7393 5no /'?t,evh4s, .T r . . 1411 4TH AVE, #1315 SEATTLE, WA 98101 Job Name and Location: DELI 6/"...: 345 ANDOVER ,-ARK: TH REVIEWED FOR TUKWILA, C DE COMPLIANCE File Code: E6 +14 / 1 / T jms APPROVED NnV 0 9 2n11 d he PROPOSAL: We a1f�seglioE,s�r t� h Aopl�s�l �oRft z Ac�ie wells U .AR eSURFACE MODIFIED BITUM 'ROOF SYSTEM _ SCOPE OE_THE WORK: he specific scope of the wn k Fir This project is: - - . _ _ _ _ _ _City of Tukwila 1. Remove edge metal and haul away for disposal. BUILDING DIVISION 2. Tear off the existing roof covering[s] down to the wood substrate. If roofing material is mo ped'selidtrto=substraterit=wil be removed to best suitable surface. Set all protruding fasteners and sweep dean and dry as necessary. During the roof removal, the substrate will be inspected for structural soundness. It is understood the owner or their approved representative will be available during the demolition and removal. This is necessary to avoid any delay while the roof is uncovered and exposed to the weather. Roof deck and structural repairs will be made and invoiced on a time [$65.00 /per man -hour] and material [plus 15 %] basis. Plywood replacement will be invoiced as follows: 3 l8in.- 1/2in. @ $1.75/square foot, 5/8in. @ $2.00 /square foot, and 3 /4in. @ $2.75 /square foot. Plywood replacement rates include labor, material, cartage, and disposal fees. 3. Fumish and install 1/2" perlite coverboard or 1/4" primed Dens -Deck. 4. Install 31b lead pipe fleshings on plumbing soil vent pipes and multiple -ply membrane stripping.. 5. Install one ply 281b fiberglass base sheet and mechanically fasten with simplex stronghold nails. 8. Install a Firestone APP -160, or equal, granular surface modified bitumen roof system per manufacturer's specifications. This is a torchgrade membrane with a manufacturer's ten (10) year limited material warranty. 7. All cants, curbs, and sharp angles will have additional flashing materials, installed per manufacturer's specifications, to indude multiple -ply membrane stripping. 8. Install new 24 gauge sheet metal perimeter flashing with baked enamel finish using gasketed galvanized nails or hex head gasketed screws. RECEIVjQ 9. Clean up and remove all debris from contracted work. CITY OF TU IA OTHER ITEMS INCLUDED IN THE SCOPE OF WORK: OCT 2 7 2011 A. Fumish and install new perlite cant strip. B. Install 70-If 24 -gauge surface mount reglet flashing with caulk joint. PERMIT CENTgR C. Raise mechanical units, install specified roof system, loose lay an additional layer of cap sheet under unit timbers reset existing timbers and/or replace unserviceable timbers with pressure treated wood; reset mechanical units D. Provide and install five (5) 3 -inch drop style scuppers_ Reconnect existing downspouts. _ _ __ __ ._. _ _ - E. install 24 -gauge sheet metal skirt flashing around curb mounted equipment as needed. T 1^ F. Fumish and install galvanized sheet metal pitchpans around gas pipe and electrical conduit penetrations. Seal in pitchpan with specified roofing materials. Fill pitchpan with plastic roof cement. Pitchpans are maintenance items. G. Remove remnants of mechanical screen and haul away for disposal. Rebuilding of screening is not included in our scope of work. - THE FOLLOWIIsLcom IFIGTIONSMOND QUALIFICATIONS ARE A PART OF THIS SCOPE OF WORK: CC VVffVV GGEE Dollars $ Terms and Conditions Listed On Reverse Side PLUS SALES TAX WARRANTIES: Our warranty for workmanship, as described on the reverse The manufacturer's warranty, which is described in their warranty which will AUTHORIZED: side, is for years. be provided to you, is for years. SIGNATURE: Associated Roofing, Inc. Associated Roofing, Inc. CUSTOMER ACCEPTANCE OF PROPOSAL This proposal is accepted. The scope of work, price, terms and conditions contained on the front and reverse of this ment co tirute the c ct IMIP SIGNATURE TITLE RETURN ORIGINAL OF THIS PROPOSAL TO: P.O. BOX 82894, KENMORE, WASHINGTON 98028 r•. Associated Roofing, Inc. ASSOCRI1620G • PROPOSAL AND CONTRACT P.O. Box 82894 This is a "plain- English" contract. "We," "us," and "our" means Kenmore, Washington 98028 Associated Roofing, Inc. "You" means the customer. 206 364 -4445 • 800 358 -3119 • 206 368 -2303 (Fax) Date: 08 -29-11 PAGE 2 OF 2 Proposal Submitted To: JARIUS STRATTON 206 -622 -7393 S TS ca0 Pr-C— 1411 4TH AVE, #1315 SEATTLE, WA 98101 Job Name and Location: DELI eet S-I-- 345 ANDOVER PARK tq' TUKWILA, WA File Code: E6+14 / 1 / TR -jms PROPOSAL: W g1 Ig�se IRo�s t i ��opt60, OR EQUAL, URFACE MODIFIED BITUMEN ROOF SYSTEM SCOPE. OF_THE_WO LRK: Thespe' `cific scope of the wnrk for_this projectis• . _ _._. EXCLUSIONS: • Temporary disconnecting, relocation, and hook -up of mechanical units to facilitate this project are not included in the scope of work and are the responsibility of the building owner. • Temporary relocation and/or realignment of satellite dishes(s) to facilitate this project are not included in the scope of work and are the responsibility of the building owner. '' QUALIFICATIONS TO BID: A. There will be dirt and debris associated with this project. If decking repairs are necessary, there is the potential for sheetrock (ceiling) damage while replacing decking. Repair to such damage is the sole responsibility of the property owner. To protect important items tenants should move, cover, or secure objects to prevent damage. Notification to the tenant(s) is the responsibility of the owner or owner's representative. Associated Roofing is not responsible for consequential damages to the structure or contents. B. As this is a construction project, there will be additional vehicle traffic and an increased level of noise. Also, as we are installing a built -up roof system, there will be an asphalt odor present. Some people may find this objectionable, however, please be assured this smell, as far as we know, has not been shown to be a health hazard. C. By acceptance of this contract, the owner or owner' s representative is stating to the best of their knowledge there is not the existence of any asbestos containing materials that will be disturbed by the performance of the specified work. D. The cost excludes all permits and fees (i.e. ,building, street/sidewalk use, or fire/torch). If required, we will obtain at the owner's expense. E. Owner to provide parking through duration of project. F. The construction industry is subject to material availability problems and escalating prices relating to asphalt and asphalt- based roofing products due to world conditions. The availability and pricing of these products are subject to sudden and significant changes beyond the control of construction contractors and their suppliers. Because of the difficulty in obtaining firm prices for petroleum —based products from suppliers, we cannot provide fixed, firm prices for asphalt products for future projects. If there is an increase in the price of petrole rrn- based_products chargedso___ _ Associated Roofing subsequent to making this proposal /contract, the price set forth in this proposal/contract shall be increased to reflect the additional cost to the roofing contractor upon roofing contractor's submittal of written documentation of the increased charges. Price valid for thirty (30) days. THE FOLLOWIIrJ,j��j,S, �i �julAU Agb SEVENUHUNDRED TH ARE THIRTY NO/100 HIS SCOPE OF WORK: 26,730.00 w� r T trV Dollars $ Terms and Conditions Listed On Reverse Side PLUS SALES TAX WARRANTIES: Our warranty for workmanship, as described on the reverse The manufacturer's warranty, which is described in their warranty which will AUTHORIZED: side, is for FIVE years. be provided to ou, is for y s. SIGNATURE: 1,ice•.- 3 Associated Roofing, Inc. Associated Roofing, Inc. CUSTOMER ACCEPTANCE OF PROPOSAL This proposal is accepted. The scope of work. price. terms and conditions contained on the front and reverse of this document constitute the contract. SIGNATURE • r TITLE R— `1" 444 DATE 4/, t/14 URN ORIGINAL OF THIS PROPOSAL TO: P.O. BOX 82894, KENMORE, WASHINGTON 98028 _ TGFU.R14571 - Roofing Systems Page 1 of 8 ONLINE CERTIFICATIONS DIRECTORY TGFU.R14571 Roofing Systems Page Bottom See General Information for Roofing Systems POLYGLASS USA INC 150 LYON DR FERNLEY, NV 89408 USA Roofing Systems SINGLE PLY MEMBRANE SYSTEMS R14571 Unless otherwise indicated, the insulation and base sheet are mechanically fastened in place; the membrane is heat welded in place. (Optional) Noncombustible deck classifications are applicable for use over combustible (15/32 in. min plywood) decks when 1/2 in. (min) gypsum board or 1/4 in. (min) G -P Gypsum "DensDeck ® Roofboard ", "DensDeck Prime@ Roofboard ", "DensDeck DuraGuard•" Roofboard" or Vs in. (min) USG Corp SECUROCKTM Roof Board Type FRX -G are used directly over the combustible deck with all joints staggered 6 in. (min) from plywood joints. Unless otherwise indicated, in any noncombustible roof deck Classification any UL Classified insulation may be utilized underneath a layer of 1/4 in. (min) G -P Gypsum "DensDeck ® Roofboard ", "DensDeck Prime@ Roofboard ", "DensDeck DuraGuard "" Roofboard" or %/a in. (min) USG Corp SECUROCKTM Roof Board Type FRX -G. General statement for use of vapor retarders and /or deck/insulation adhesives (NC decks only): When such vapor retarders or deck/insulation adhesives are acceptable to POLYGLASS they may be utilized. "POLYGLASS BASE ", "MODIBASE ", "Polyglass G2 Base" may be used in lieu of any Type G2 base sheet in any NC Classification. These products may also be used in any C -15/32 Classification in which a generic Type G2 is referenced (i.e. not brand specific). " POLYGLASS Ply 4 ", " POLYGLASS Ply 6" (Type GS) and "POLYGLASS VENTED BASE" may be used in any NC Classification. These products may also be used in any C -15/32 Classification in which a generic Type G1 is referenced (i.e. not brand specific). References to polyisocyanurate insulation may Include Polyglass Products "POLYTHERM ®" and "POLYTHERM® Tapered ". Acceptable alternates to the membranes listed are given below: Membrane Listed Acceptable Alternatives "POLYBOND" "MODIBOND" "POLYBOND G" "MODIBOND G" "Polytherm ", " Polytherm Tapered" or "Polytherm Composite" insulations may be used wherever polyisocyanurate insulations are specified in the Classifications below. Insulation may be optional for any non - combustible deck roofing system unless the insulation acts as a coverboard over another insulation. Class A - Ballasted Incline: 3 1. Deck: C -15/32 Insulation: — Polyisocyanurate, urethane, perlite / polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic or perlite, any thickness. Ply or Base Sheet: — One ply "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or "ELASTOSHIELD TS G ". Membrane: — One or more layers "POLYGLASS 350 CAP ", "POLYFRESKO 350 CAP ", "POLYBOND ", " POLYBOND G ", "POLYFLEX ", "POLYFRESKO TORCH" or "POLYFLEX G" (modified bitumen), heat welded, or one or more layers "ELASTOFLEX V ", " ELASTOFLEX V -C ", "ELASTOBASE ", " ELASTOFLEX S6 ", " ELASTOFLEX P -C" or "ELASTOSHIELD TS G ", mopped in hot asphalt or heat fused. Surfacing: — Gravel, embedded in hot mopping asphalt. Class B - Ballasted http: // database. ul .com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 9/15/2011 i ur u.1c1'+J 11 - /cowing aystems rage L 01 1. Deck: C -15/32 Incline: 3 Base Sheet: — Type G2. Membrane: — "POLYBOND ", " POLYGLASS 350 CAP", "POLYFRESKO 350 CAP ", "POLYBOND G ", "POLYFLEX ", " POLYFRESKO TORCH ", "POLYFLEX G" (modified bitumen), heat welded, or one or more layers " ELASTOFLEX V ", " ELASTOFLEX V -C ", "ELASTOBASE ", " ELASTOFLEX S6 ", " ELASTOFLEX P -C" or "ELASTOSHIELD TS G ", mopped in hot asphalt. Surfacing: — Gravel, embedded in hot mopping asphalt or heat fused. Class A - Fully Adhered 1. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite/urethane composite, glass fiber, phenolic or perlite, any thickness. Base Sheet: — One or more layers "ELASTOBASE ", "POLYFLEX ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", " POLYFRESKO TORCH" or "POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Kokem Products "Sunguard Acrylic Roof Coating" at 1 gal/sq; or Kamak No. 97 Fibrated Aluminum Asphalt Roof Coating or Karnak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 44 -1 gal. /sq. . 2. Deck: C -15/32 Incline: 1/2 Insulation: — Two or more layers (insulation joints staggered a min of 6 in. from plywood deck joints) polyisocyanurate, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic or perlite, any thickness. Base Sheet: — One or more layers "ELASTOBASE ", "POLYFLEX ", " ELASTOFLEX V" , " ELASTOFLEX V -C" or Type G2 base sheet. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", " POLYFRESKO TORCH" or "POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal/sq. or Kokem Products "Sunguard Acrylic Roof Coating" at 1 gal /sq; or Kamak No. 97 Fibrated Aluminum Asphalt Roof Coating or Kamak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq.. 3. Deck: C-15/32 Incline: 1/2 Insulation: — 1/4 in. thick G -P Gypsum DensDeck®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Base or Ply Sheet: — One or more layers "POLYFLEX" (mechanically fastened or heat welded), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (mechanically fastened or hot mopped). Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", " POLYFRESKO TORCH" or "POLYFLEX G" (modified bitumen), heat welded or hot mopped. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3-4 gat /sq. or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro-Grade Aluminum Roof Coating ", 1.5 gal /sq; or Karnak No. 97 Fibrated Aluminum Asphalt Roof Coating or Kamak No. 97 Asbestos Free Aluminum Roof Coating at 1 to 2 gal/ sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3A4 -1 gal. /sq.. 4. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite, wood fiber, any combination, any thickness. Base Sheet: — " POLYFLEX" (mechanically fastened or heat welded) or Type G2, mechanically fastened or hot mopped. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", " POLYFRESKO TORCH" or "POLYFLEX G" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Grundy Industries "al MB Aluminum Roof Coating" at 1 -2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 3/4-1 gal. /sq.. 5. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, urethane, perlite /polyisocyanurate composite, perlite /urethane composite, glass fiber, phenolic, perlite or wood fiberboard, any thickness. Base Sheet: — One or more layers "POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V", "ELASTOFLEX V- C" or Type G2 base sheet (hot mopped, heat fused or mechanically fastened). Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 6. Deck: C -15/32 Incline: 1/2 Base Sheet: — One or more layers "POLYFLEX" or "POLYGLASS Base" (heat fused or mechanically fastened), "ELASTOBASE ", "ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped, heat fused or mechanically fastened). Ply Sheet: — One or more layers "POLYFLEX" or "POLYGLASS Base" (heat fused) or " POLYGLASS Base ", "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped) or mechanically attached. Membrane: — "DUFLEX G FR ", " POLYFRESKO TORCH FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 7. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 In. min), perlite (3/4 in. min), glass fiber (7/16 in. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min) or (2 In. min) polyisocyanurate covered with 1/2 in. perlite or wood fiberboard. http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 9/15/2011 TGFU.R14571 - Roofing Systems Page 3 of 8 Base Sheet: — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V- C" (heat fused, mechanically fastened or hot mopped) or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet — One or more layers " POLYFLEX" (heat fused) "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped) or mechanically fastened. Membrane: — "DUFLEX G FR", "POLYFRESKO TORCH FR" or " POLYFLEX G FR" (modified bitumen), heat fused. 8. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, urethane, periite /polyisocyanurate composite, perlite /urethane composite, glass fiber or wood fiberboard, phenolic or periite, any thickness. Base Sheet — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V- C" (hot mopped, mechanically fastened or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — "ELASTOSHIELD TS G FR ", " ELASTOFLEX S6 G FR" or "POLYFRESKO MOP FR" (modified bitumen), hot mopped or heat fused. 9. Deck: C -15/32 Incline: 1/2 Base Sheet: — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet: — One or more layers "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically attached). Membrane: — " ELASTOFLEX S6 G FR', "POLYFRESKO MOP FR" or "ELASTOSHIELD TS G FR" (modified bitumen), hot mopped or heat fused. 10. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), periite (3/4 in. min), glass fiber (15/16 in. min), periite / poiyisocyanurate composite, periite /urethane composite (2 in. min). Base Sheet: — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V- C" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet: — One or more layers "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically attached). Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or "ELASTOSHIELD TS G FR" (modified bitumen), hot mopped or heat fused. 11. Deck: NC Incline: 1 Insulation (Optional): — Cellular concrete, gypsum concrete, vermiculite concrete, perlite concrete or structural concrete. Primer: — Not UL Classified — as required by manufacturer. Membrane: — "POLYBOND ", "POLYBOND G ", "POLYFLEX ", " POLYFLEX G ", " POLYFLEX G FR ", " POLYFRESKO TORCH FR ", "POLYFLEX ", "POLYFLEX G ", "DUFLEX G FR" or "POLYFLEX G FR ". Surfacing: — (not required for "POLYFLEX G FR ", " POLYFRESKO TORCH FR" or "DUFLEX G FR" ) "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Monsey Products "Endure Aluminum Roof Coating ", at 1.5 gal /sq; or Grundy Industries "al MB Aluminum Roof Coating ", at 1 -2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 34 -1 gal. /sq. 12. Deck: NC Incline: 1 Insulation (Optional): — Any thickness, one or more layers UL Classified periite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate /composite, EPS /wood fiber, EPS /perlite or EPS /composite. Base Sheet: — One or more layers Type G1 or G2. Membrane: — One or more layers "POLYBOND ", "POLYBOND G ", " POLYFLEX" or "POLYFLEX G" (modified bitumen), heat fused. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Fields "F350 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating ", 1 -1/2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPius 60 ", applied at 34 -1 gal. /sq. 13. Deck: NC Incline: 1/2 Barrier Board (Optional): — 1/2 in. gypsum board. Insulation (Optional): — Polyisocyanurate, any thickness. Base Sheet (Optional): — Type G2, "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or "POLYFLEX ". Membrane: — " POLYFLEX G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR" (heat fused), "ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" (hot mopped) or "ELASTOSHIELD TS G FR" (heat fused or hot mopped). 14. Deck: C -15/32 Incline: 1 Insulation: — 1/4 in. thick G -P Gypsum DensDeck®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Ply Sheet — Type G2, mechanically fastened. Membrane: — "POLYBOND ", " POLYFLEX" (modified bitumen), heat welded. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro -Grade Aluminum Roof Coating ", 1.5 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at 34 -1 gal. /sq. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 9/15/2011 TGFU.R14571 - Roofing Systems Page 4 of 8 15. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, perlite, glass fiber or wood fiberboard, any thickness. Base Sheet: — On ply Type G2, hot mopped or mechanically fastened or "ELASTOBASE ", heat fused, hot mopped or mechanically fastened. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or " ELASTOSHIELD TS G FR" hot mopped or heat fused. 16. Deck: C -15/32 Incline: 1/2 Base Sheet: — One ply Type G2 or "ELASTOBASE ", mechanically fastened. Ply Sheet: — One ply Type G2 (hot mopped or mechanically fastened) or "ELASTOBASE" (hot mopped, heat fused or mechanically fastened). Insulation (Optional): — Polyisocyanurate, perllte, glass fiber, any thickness. Membrane: — " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR" or, ELASTOSHIELD TS G FR " hot mopped or heat fused. 17. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite / polyisocyanurate composite, perlite /urethane composite (2 in. min). Base Sheet: — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V- C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet (Optional): — One or more layers "POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" (hot mopped or heat fused) or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — " DUFLEX G FR ", " POLYFRESKO TORCH FR" or "POLYFLEX G FR" (modified bitumen), heat fused. 18. Deck: C-15/32 Incline: 1/2 Insulation: — Polylsocyanurate (2 In. min), glass fiber (15/16 In. min), perlite/polylsocyanurate composite, perlite /urethane composite (2 In. min). Base Sheet: — One or more layers " POLYFLEX" (heat fused or mechanically fastened), "ELASTOBASE ", " ELASTOFLEX V" or Type G2 base sheet (hot mopped or mechanically fastened). Ply Sheet (Optional): — One or more layers " POLYFLEX" (heat fused), "ELASTOBASE ", " ELASTOFLEX V ", " ELASTOFLEX V -C" or Type G2 base sheet (hot mopped or mechanically fastened). Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX 56 G -C" or "POLYFRESKO MOP" (modified bitumen), hot mopped. 19. Deck: C -15/32 Incline: 1 Insulation: — 1/4 in. thick G -P Gypsum DensDeck ®, perlite, wood fiber or glass fiber, 1 in., mechanically fastened. Ply Sheet: — Type G2, mechanically fastened. Membrane: — "POLYFLEX ", heat welded. Surfacing: — Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro-Grade Aluminum Roof Coating ", 1.5 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPlus 60 ", applied at Vis-1 gal. /sq.. 20. Deck: C -15/32 Incline: 2 -1/2 Barrier Board: — 1/4 In. (min) G -P Gypsum DensDeck® with all joints staggered 6 In. from the plywood joints. Base Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX G FR" or "POLYFRESKO TORCH FR ", heat fused in place. 21. Deck: C -15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate/perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all jolnts staggered 6 in. from the plywood joints. Base Sheet: — " ELASTOBASE" (poly /sand), mechanically fastened or "ELASTOFLEX SA V PLUS FR "or "ELASTOFLEX SA V FR BASE VENT" (self adhered). Ply Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT ", (self adhered) or "POLYFLEX G FR ", " POLYFRESKO TORCH FR ", " DUFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", "ELASTOSHIELD TS G FR ", heat fused. 22. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Polylsocyanurate 1.5 in. (min.) with all joints staggered 6 -in. (min.) from the plywood joints. Base Sheet: — Type G2, mechanically fastened followed by "ELASTOBASE ", mechanically fastened. Ply Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT", (self adhered). Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", or "DUFLEX G FR ", "POLYFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", " ELASTOSHIELD TS G FR ", heat fused. 23. Deck: NC Incline: 2 http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME/showpage.html ?name =T... 9/15/2011 TGFU.R14571 - Roofing Systems Page 5 of 8 Insulation (Optional): — Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H- Shield ", any thickness. Base Sheet: — " ELASTOBASE" (poly /sand), heat fused or mechanically fastened or "ELASTOFLEX SA V FR ", " ELASTOFLEX SA V PLUS FR" or " ELASTOFLEX SA V FR BASE VENT', (self adhered). Membrane: — "POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or "POLYFLEX G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", " ELASTOSHIELD TS G FR ", heat fused. 24. Deck: C -15/32 Incline: 3 Insulation (Optional): — Polyisocyanurate, pulite, wood fiber or polyisocyanurate /perlite board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck ®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — " ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet (Optional): — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT, (self adhered). Membrane: — " ELASTOFLEX S6 G FR" or " POLYFRESKO MOP FR ", heat fused. 25. Deck: NC Incline: 3 Insulation (Optional) : — Atlas Roofing "ACFoam III" or "ACFoam II" or Hunter Panels "H- Shield ", any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR" or " ELASTOFLEX SA V FR BASE VENT" (self adhered). Membrane: — "POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR" or " POLYFRESKO SBS SA P FR" (self adhered). 26. Deck: NC Incline: 1/2 Base Sheet: — Type Gi or G2, mechanically fastened. Membrane: — "POLYFLEX G" or "POLYBOND G ", heat fused. 27. Deck: NC Incline: 3 Membrane: — "POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR", " POLYFRESKO SBS SA P FR "or "ELASTOFLEX SA P FR" (self adhered). 28. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V ", " ELASTOFLEX SA V PLUS" or "ELASTOFLEX SA V BASE VENT', self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Membrane: — "POLYFLEX SA P" or "POLYFRESKO APP SA P" self- adhered. 29. Deck: C -15/32 Incline: 1/2 Insulation: — Polyisocyanurate (2 in. min), glass fiber (15/16 in. min), perlite /polyisocyanurate composite, perlite /urethane composite (2 in. min). Barrier Board: — 1/4 In. (min) G -P Gypsum DensDeck ®, mechanically fastened, with 6 In. offset to plywood joints. Base Sheet: — " ELASTOFLEX S6 ", " ELASTOFLEX P -C" (heat fused or mechanically fastened). Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or "POLYFRESKO MOP ", (heat fused). 30. Deck: NC Incline: 1/2 Insulation (Optional) — Atlas Roofing "ACFoam III" or "ACFoam II ", any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT', (self adhered). Membrane: — "POLYKOOL SA" (self adhered). 31. Deck: 5/32 Incline: 1/2 Base Sheet: — G2 Base sheet mechanically fastened followed by "ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT', (self adhered). Membrane: — "POLYKOOL SA" (self adhered). 32. Deck: NC Incline: 1/2 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V PLUS" or " ELASTOFLEX SA V BASE VENT ", self- adhered or " ELASTOBASE" (poly /sand), mechanically fastened. Membrane: — " ELASTOFLEX S6 G ", " ELASTOFLEX S6 G -C" or "POLYFRESKO MOP ", heat fused. 33. Deck: NC Incline: 1 -1/4 Insulation (Optional): — Any UL Classified Isocyanate or polyurethane, any thickness. http: // database. ul. com /cgi- bin/XYV /template/LISEXT/ 1 FRAME /showpage.html ?name =T... 9/15/2011 ti �, TGFU.R14571 - Roofing Systems Page 6 of 8 Base sheet: — " ELASTOFLEX SA V PLUS FR" or "ELASTOFLEX SA V FR BASE VENT", self adhered. Membrane: — "POLYKOOL SA" self adhered. 34. Deck: NC Incline: 1 Insulation (Optional): — Any UL Classified polylsocyanate, any thickness. Base Sheet: — " ELASTOFLEX SA V PLUS FR" or " ELASTOFLEX SA V FR BASE VENT ", self adhered. Membrane: — "POLYBIANKO APP SAP ", self adhered. 35. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, glass fiber, perlite or wood fiberboard any thickness, any combination, mechanically fastened or hot mopped in place. Base Sheet: — Type G2, "ELASTOBASE ", "MODIBASE" or " ELASTOFLEX V ", mechanically fastened. Ply sheet (Optional): — Type G2, "ELASTOBASE ", "MODIBASE" or "ELASTOFLEX V ", \' ELASTOFLEX S6 ", " POLYFLEX" or "DUFLEX" adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", " POLYFLEX G FR" (sand- backed) or DUFLEX G FR" (sand-backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 36. Deck: C -15/32 Incline: 1 Insulation (Optional): — Polyisocyanurate (1.3 in. min), glass fiber (7/16 in. min) or perlite (3/4 in. min), mechanically fastened or hot mopped in place. Base Sheet: — Two plies Type G2, first ply mechanically fastened and the second ply fully adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", " POLYFLEX G FR" (sand- backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 37. Deck: C -15/32 Incline: 1 Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Insulation (Optional): — Polyisocyanurate, glass fiber, wood fiberboard, any thickness, mechanically fastened. Base sheet: — Type G2, one or more plies, mechanically fastened. Ply sheet (Optional): — Type G2, "ELASTOBASE ", " ELASTOFLEX V ", " POLYFLEX" or "DUFLEX" (sand- backed) adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", "ELASTOSHIELD TS4 FR ", " POLYFLEX G FR" (sand- backed) or DUFLEX G FR" (sand- backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. 38. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, polyisocyanurate /perlite composite, glass fiber, perlite or wood fiberboard, any combination, any thickness or polystyrene any thichness covered with 44 in. perlite, 1/4 In. (min) G -P Gypsum DensDeck®, 7/16 in. glass fiber or 1 in. wood fiberboard, mechanically fastened. Base Sheet: — "Type G2, "ELASTOFEX V ", adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal /sq. Membrane: — " ELASTOFLEX G S6 FR ", " ELASTOFLEX VG FR ", ELASTOSHIELD TS4 FR ", " POLYFLEX G FR" (sand - backed) or DUFLEX G FR" (sand- backed), adhered with Alco Products "SBS Modified Bitumen Adhesive No. 269" at 1 to 1 -1/2 gal/sq. Class B - Fully Adhered 1. Deck: C -15/32 Incline: 1/4 Base Sheet: — Two or more layers "POLYFLEX" (mechanically fastened or heat fused), "ELASTOBASE ", Type G2 GAF Building Materials "GAFGIas #75 ", Johns Manville "GLASBASE" or Celotex "Vaporbar GB" (mechanically fastened or hot mopped in place). Membrane: — " POLYFLEX G" (modified bitumen), heat welded. 2. Deck: C -15/32 Incline: 1/2 Insulation (Optional): — Any thickness, one or more layers UL Classified perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate /composite, EPS /wood fiber, EPS / perlite or EPS /composite roof insulation. Base Sheet — One or more layers Type G1 or G2. , Membrane: — One or more layers "POLYFLEX G FR ", "POLYFRESKO TORCH FR ", "POLYBOND ", "POLYBOND G ", " POLYFLEX" or " POLYFLEX G" (modified bitumen), heat fused. Surfacing: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Fields "F530 Heat Shield Aluminum Coating" or "F630 Heat Shield Fibered Aluminum Coating ", 1 -1/2 gal /sq; or Monsey Products "Endure Aluminum Roof Coating ", "Weather Check" or "Pro - Grade Aluminum Roof Coating ", 1 -1/2 gal /sq; or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq., followed by "PolyPius 60 ", applied at 3/4-1 gal. /sq. 3. Deck: C -15/32 Incline: 1 -1/2 Base Sheet: — Type G2 or "ELASTOBASE ", mechanically fastened. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 9/15/2011 TGFU.R14571 - Roofing Systems Page 7 of 8 Ply Sheet: — "Polyglass Base ", heat fused. Membrane: — " POLYFLEX G FR" or " POLYFRESKO TORCH FR" (modified bitumen), heat fused. 4. Deck: 15/32 Incline: 1 -1/2 Insulation: — Glass fiber (15/16 in. min.), mechanically fastened. Base Sheet: — Type G2 base or "ELASTOBASE ", hot mopped or mechanically fastened. Membrane: — " POLYFLEX G FR" or "POLYFRESKO TORCH FR" (modified bitumen), heat fused. 5. Deck: C -15/32 Incline: 1/2 Base Sheet: — Type G2, mechanically fastened. Membrane: — " POLYFLEX G" or "POLYBOND G ", heat fused. 6.. Deck: NC Incline: 1 Insulation (Optional): — Polyisocyanurate, any thickness. Base sheet (Optional): — " ELASTOFLEX SA V PLUS" or "ELASTOFLEX SA V BASE VENT', self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet (Optional): — "POLYFLEX ", heat fused. Membrane: — " POLYFLEX SA P ", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", " POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G ", heat fused. 7. Deck: C -15/32 Incline: 1 /2 Insulation (Optional): — Polyisocyanurate, any thickness. Barrier Board: — 1 /4 -In. (min) GP Gypsum DensDeck® or DensDeck Prime®, mechanically fastened. Base sheet: — "ELASTOBASE" (poly /sand), mechanically fastened. Ply sheet (Optional): — " ELASTOFLEX SA V PLUS" or " ELASTOFLEX SA V BASE VENT", self- adhered. Membrane: — " POLYFLEX SA P ", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", " POLYFRESKO SBS SA P ", self - adhered or 'POLYFLEX G ", heat fused. 8. Deck: C -15/32 Incline: 1/4 Base sheet (Optional): — "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet: — " ELASTOFLEX SA V PLUS" or "ELASTOFLEX SA V BASE VENT', self- adhered or "ELASTOBASE ", mechanically fastened. Membrane: — " POLYFLEX SA P ", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", " POLYFRESKO SBS SA P ", self - adhered or 'POLYFLEX G ", heat fused. 9. Deck: NC Incline: 1 Insulation: — Any UL Classified, any thickness. Barrier Board: — 1/4, 3/8, 1/2 or 5 /8 -in. thick USG Corp "SECUROCK" Roof Board (Type FRX -G)" Base sheet (Optional): — " ELASTOFLEX SA V PLUS" or "ELASTOFLEX SA V BASE VENT ", self- adhered or "ELASTOBASE" (poly /sand), mechanically fastened. Ply Sheet (Optional): — "POLYFLEX ", heat fused. Membrane: — " POLYFLEX SA P", " POLYFRESKO APP SA P ", " ELASTOFLEX SA P ", " POLYFRESKO SBS SA P ", self- adhered or 'POLYFLEX G ", heat fused. 10. Deck: C -15/32 Incline: 2 Insulation (Optional): — Polyisocyanurate, perlite, wood fiber or polyisocyanurate/perllte board, any thickness. Barrier Board: — 1/4 in. (min) G -P Gypsum DensDeck®, mechanically fastened with all joints staggered 6 in. from the plywood joints. Base Sheet: — "ELASTOBASE" (poly /sand), mechanically fastened, heat fused or hot mopped. Ply Sheet (Optional): — "ELASTOBASE" (poly /sand), mechanically fastened, heat fused or hot mopped. Membrane: — " POLYFLEX SA P FR ", " POLYFRESKO APP SA P FR ", " ELASTOFLEX SA P FR ", " POLYFRESKO SBS SA P FR ", " ELASTOFLEX SA V FR HT", (self adhered) or "POLYFLEX G FR ", " POLYFRESKO TORCH FR ", "DUFLEX G FR ", " ELASTOFLEX S6 G FR ", " POLYFRESKO MOP FR ", "ELASTOSHIELD TS G FR ", heat fused or hot mopped. Class C - Fully Adhered 1. Deck: C -15/32 Incline: 2 Base Sheet: — Johns Manville "Perma Ply IV" (Type G2). Membrane: — " POLYBOND G ", " POLYFLEX G ", " POLYFRESKO TORCH FR" or "POLYFLEX G FR" (modified bitumen), heat welded. OTHER SYSTEMS http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 9/15/2011 TGFU.R14571 - Roofing Systems 1. Deck: C -15/32 or spaced sheathing Incline: Unlimited Underlayment: — One layer Elk Corp "VersaShield ", mechanically fastened. Ply Sheet: — One ply "Polystick MTS" (self adhered). Surfacing: — Any UL Listed or Classified copper or steel standing seam panels or shingles, 26 gauge min. 2. Deck: NC Incline: Unlimited Insulation: — Any UL Classified polyisocyanurate, any thickness. Underlayment: — One ply "Polystick MTS" (self adhered). Surfacing: — Any UL Listed or Classified copper or steel standing seam panels or shingles, 26 gauge min. 1. Deck: C -15/32 MAINTENANCE AND REPAIR SYSTEMS Class A, B and C Incline: 1 Page 8 of 8 Existing Roof System: — (To maintain existing Classifications) - Any Class A, B or C, uncoated, insulated or uninsulated, modified bitumen membrane or Type G3 mineral surfaced cap BUR system. Base Coat: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq. Top Coat: — "PolyBrite 70 ", applied at 1.5 gal. /sq. 2. Deck: C -15/32 Incline: 1 Existing Roof System: — (To maintain existing Classifications) - Any Class A, B or C, uncoated, insulated or uninsulated, modified bitumen membrane or Type G3 mineral surfaced cap.BUR system. Base Coat: — "PG 800 Asphalt Emulsion Roof Coating ", applied at 3 -4 gal /sq. or Brewer "Fortress 5001 Asphalt Emulsion ", applied at 4 gal. /sq. Top Coat: — "PolyPlus 60 ", applied at 3/4-1 gal. /sq. Last Updated on 2011 -08 -23 Questions? Print this page Notice of Disclaimer Page Top Copyright © 2011 Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and /or Listings (files) must be presented in their entirety and in a non - misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright O 2011 Underwriters Laboratories Inc.®" An independent organization working for a safer world with Integrity, precision and knowledge. http: // database. ul. com /cgi- bin/XYV /template/LISEXT /1 FRAME /showpage.html ?name =T... 9/15/2011 Cap Sheet Roofing Guide Specification For: • WATERPROOFING MATERIALS AND INSULATING SYSTEMS Spec # 200W APP TOR Project Name: DELI Address: 345 Andover Park East City, State, Zip: Tukwila,WA,98188 Size: 5,600 Base Sheet - --- `Mechanically Attached, Per Specification) Base Sheet : Polyglass Base Cap Sheet : Polyflex G Prepared by: Neisinger, William Please see the POLYGLASS Technical Guide or contact POLYGLASS Technical Support for further information regarding slope limitations and specific application requirements a POLYGLASS Torch Applied Roofing System. This specification is provided as a general guide for use of POLYGLASS products based on typical building conditions and standard roofing practices. POLYGLASS is strictly a manufacturer of roofing systems and has no experience, training or expertise in the areas of architecture /engineering or in the area of consulting with respect to matters related to such areas. PART 1 GENERAL 1.01 General Notes Preceding the start up of job, the contractor shall decide to his satisfaction that all the specifications are workable as specified, that there is nothing that would deter the contractor s required warranty, and that no existing conditions at the site prevent the contractor from performing the job in a professional and safe manner. When the job starts, it will be assumed that the contractor approves the existing conditions and the specifications. 1.02 Description Provide all labor, materials, equipment, supervision and incidentals as needed to install a complete Polyglass reinforced modified bituminous roofing system over a new or accepted, prepared exiting roof substrate. All details of installation shall conform to Polyglass Specifications, Details and General Recommendations. 1.03 Quality Assurance Products used in the work of this Section shall be manufactured by Polyglass or accepted for use in conjunction with the products manufactured by Polyglass. The Roofing Contractor and his personnel shall be currently accepted by Polyglass as qualified to install the materials of this section. Do not apply roofing during inclement weather. Do not apply roofing membrane to damp frozen, dirty or dusty surfaces. Part 2 PRODUCTS 2.01 Polyglass Base - An APP modified bitumen roofing membrane base sheet, reinforced with a fiberglass mat, saturated and coated with a polymerized asphaltic compound with exceptional waterproofing and weatherability. Specially designed for heat welding, cold -apply and mechanically attached applications. Top and bottom surfaces are finished with polyolefin film or sand. 2.02 Polyflex G - Premium, polyester reinforced APP modified bitumen roofing membranes specially designed for heat welded and cold -apply applications. Membrane is also used as a flashing in all applicable specifications, in accordance with recommended installation practices. Membrane is polyester reinforced, lightweight, weather resistant and durable. Top surface of membrane is granular except at selvage, which is granule free. 2.03 Asphalt Primer Meeting ASTM D 41 specification, applied in strict conformance to manufacturers recommendations. 2.04 Asphalt Meeting ASTM D 312 Type III or IV. Follow installation recommendations of the NRCA (National Roofing Contractors Association) 2.05 Surface Coating (where required by specification) emulsion coating, asphalt latex emulsion roof surfacing material, asphaltic based aluminum roof coating (fibrated or non- fibrated) or a colored acrylic coating, may be required to meet necessary fire code approvals. Consult Polyglass Technical Service Department, 1- 800 - 894 -4563 for fire rated assembly information. 2.06 Product Handling a. All materials, except those that are shop fabricated shall be delivered to the job site with their original labels intact. Bulk materials shall be identified by the manufacturer as to specification issued. b. All materials shall be stored in accordance with the instructions of the manufacturer prior to their application or installation. No wet or damaged materials will be used in the application. Materials stored on the job site shall be a minimum 4" off the ground of the roof. c. Application of all roofing shall be (6 stave accomplished in such a way that each area will be complete at the end of each days work. All roof edges and incomplete flashing shall be protected against water entry, particularly between work periods. d. When ambient temperature is below 40 degrees F, care must be exercised in handling and storing Polyglass membrane. Only rolls for immediate application shall be exposed to the elements. All masonry, concrete and sheet metal surfaces incorporated into the roof system shall be primed with asphalt primer meeting ASTM 0-41 specification and allowed to dry prior to installing bituminous roofing materials. e. Wood curbs or nailers, where required, shall be pressure treated with accepted pressure treatment meeting AWAP Standard P-5. Part 3 Execution 3.01 General Preparation The roof surface, which is to receive the Polyglass roofing system, shall be smooth, clean, free from loose gravel, dirt and debris, dry and structurally sound 3.02 Reroofing a. Remove existing roof flashings from curbs and parapet walls down to the surface of the roof. Remove existing flashings at roof drains and roof penetrations. b. Remove all wet, deteriorated, blistered or delaminated roofing membrane or insulation and fill in any low spots occurring as a result of removal work, to create a smooth even surface for application of new roof membranes. c. Existing roof surfaces shall be primed as necessary with asphalt primer meeting ASTM 0-41 specification and allowed to dry prior to installing the Polyglass roofing system. 3.03 Installation a. Decks Prime where required, in accordance with requirements and recommendations of the primer and deck manufacturer (if applicable). b. Where a vapor retarder is required by the specifier Follow the instructions with regard to the particular materials specified and install in accordance with the recommendations of the manufacturer and the requirements of the architect. 3.04 Membrane a. The corresponding application methods will appear here b. For each method selected 3.05 Flashing a. The flashing shall be installed using Polyglass flashing sheets and minimum 6" wide Polyglass stripping sheets. The stripping sheet shall be installed with a minimum of three inches in both the horizontal and vertical surfaces. The flashing sheets shall be installed with a minimum of six inches on the horizontal surface and extend a minimum of eight inches above the finished roof surface. b. The flashing sheets shall be installed by the same application method used for the roof membranes. In hot mop applications the flashing sheets may be installed by heat weld application provide the proper flashing materials are utilized. The top edge of the flashing sheet shall be secured using a termination bar (only when the wall surface above is waterproofed), or nailed 4" on center and covered with an acceptable counter flashing. c. Items related to reproofing operations such as sheet metal gravel stops, roof vents, and similar items shall be incorporated into the new roof system in accordance with the recommendations described in the current issued of the Polyglass "Specifications and Details" manual NOTE: Never use torch or apply torched materials to areas of combustible materials. Any combustible material must first be overlaid Page 3 eA MAW with a protective barrier or alternatively remove such materials from the location. Use common sense in the application of torches. Always keep a suitable, prepared, fire extinguisher available at each area where torching occurs. POLYFLEX® G PRODUCT DESCRIPTION Polyflex G membranes are premium, polyester reinforced APP modified bitumen roofing membranes specially designed for heat-welded applications. Constructed with premium Atactic Polypropylene resins, and incorporating superior polyester reinforcing, Polyflex G provides an exceptionally durable roofing product which is easy to install and will provide long -term weathering performance. With a granulated surface (available in several colors) and either a polyolefin or sand backing, Polyflex G exceeds all minimum ASTM standards for tensile strength, puncture resistance and flexibility. Polyflex G membranes can also be used as flashing membranes in all applicable specifications, in accordance with recommended installation practices. USES • Heat- welded or cold - applied cap sheet • Applied directly over an acceptable substrate or as part of a multi -ply system • New roofing, re- roofing, re -cover and for flashing details FEATURES AND BENEFITS • Exceptional weathering characteristics • Puncture and tear resistant • low -temp flexibility, exceptional tensile strength and elongation properties TECHNICAL DESCRIPTION ES .TT METHOD •': ASTM D5147 PROPERTY, ' ; Thickness, typical, mm (mils) TYPICAL -'VALUE. 4.5 (180) ASTM D5147 Peak Load @ 23 + / -2C (73.4 + /- 3.6F), MD and XMD, min, kN /m (Ibf /in.) 8.8 (50) ASTM D5147 Elongation @ 23 + / -2C )73.4 + /- 3.6F), MD and XMD, min ( %) 23 ASTM D5147 Tear Strength @ 23 + / -2C (73.4 + /- 3.6F), min, N (Ibf) 311 (70) ASTM D5147 Low Temperature Flexibility, max, C (F) 0 (32) ASTM D5147 Granule Embedment, g 2 AVAILABLE COLORS Top surface granule protection is available in a variety of colors such as: Black Buff Chestnut Grey Slate Oak White Red Blend Pine Green Heather Blend Weatherwood 10/2010 PRODUCT DATA Coverage (Approx) 100 sq ft Weight 110 Ibs Roll Size 32'10" x 39 3 /e" (l Om x 1 m) Rolls /Pallet 20 APPLICABLE STANDARDS • ASTM D 6222 Type I • Miami Dade Code Compliance • Factory Mutual Approved • UL Classified for use in class A, B or C roofs, as listed in the latest UL "Roofing Materials and Systems Directory' • ICC ESR -2018 • TDI 61 asp wwam IN PRODUCT WARRANTY Unless otherwise incorporated into or part of a supplemental manufacturer's warranty, Polyglass warrants its product(s) for a period of 10 years against manufacturing defects in its product that directly results in leakage. Warranty coverage is an annually declining pro-rated warranty. WATERPROOFING MATERIALS AND INSULATING SYSTEMS POLYGLASS' G R O U P Adis eatae! 1- 800 -222 -9782 www.polyglass.com POLYFLEX° G APPLICATION INSTRUCTIONS Polyflex G is intended to be used as the primary weathering surface in new or re -roof applications. Polyflex G is to be applied as the outermost layer of a multi -ply roof system over a compatible Polyglass base or inner ply sheet. Polyflex G may be applied directly to non -combustible substrates. • Apply over clean, dry, dust and debris -free substrates. Prime concrete decks prior to application with PG 100 Asphalt Primer. • When re- roofing, remove all prior roofing materials down to a clean debris -free substrate and properly close -off all abandoned roof penetrations. • Concrete or steel decks shall be designed with proper expansion devices. • Wood decks shall have all joints blocked and properly supported. • Ensure the fire rating of the assembly over any combustible substrate. • Ensure the installation of Polyflex G does not prevent the ventilation of existing construction. • Do not apply over shingles or any granulated surface. • While installing Polyflex G: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax in the sun for at least 15 minutes. 3. Install with traditional torch roofing techniques ensuring proper heating of the roofing material as not to expose the reinforcement. 4. Do not heat the substrate. 5. Position successive rolls providing a minimum 6" end lap and 3" side lap. Asphalt bleed out shall be 1/4" to 3/8" on all seams. 6. Laps shall be rolled with a 6" -wide roller immediately after heat welding. • Details and flashing may be installed using Polyflex G with torch applied techniques. Do not use cold adhesives or hot asphalt. Check project details for proper installation requirements. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Winter Haven, FL ETERPROOFIN&MATERIALS AND INSULATING SYSTEMS ALL DATA FURNISHED REFERS TO STANDARD PRODUCTION AND 15 GIVEN IN GOOD FAITH WITHIN THE APPUCAAIF MANUFACTURING AND TESTING TOLERANCES POLYG1AS5 USA, INC., RESERVES THE RIGHT TO IMPROVE AND CHANGE ITS PRODUCTS AT ANY TIME WITHOUT PRIOR NOTICE. POLYGLASS USA, INC. CANNOT BE HELD RESPONSIBLE FOR THE USE OF ITS PRODUCTS UNDER CONDITONS BEYOND ITS OWN CONTROL. OLYGLASS G R O U P lib two' 1- 800 -222 -9782 www.polyglass.com ASTM C728 - 05(2010) Standard Specification for Perlite Thermal Insulation Board Back to Thermal Insulation Standards ASTM C728 - 05(2010) Page 1 of 2 ASTM C728 - 05(2010) Standard Specification for Perlite Thermal Insulation Board Active Standard ASTM C728 Developed by Subcommittee: C16.22 (Book of Standards Volume: 04.06 Buy Standard (PDF) more info 3 pages $ 34.00 Buy Standard (Print) more info 3 pages $ 34.00 ASTM C728 Abstract This specification covers the composition and physical properties for perlite thermal insulation board used principally above structural roof decks and as a base for built -up, modified, and elastomeric membrane roofing in building construction. Perlite thermal insulation board is classified as follows: type 1 - roof insulation board, and type 2 - roof cover /recover board. The basic material of the insulation bo s a p e er rte expanded by the application of heat to torm glassy, cellular aggregates. The finished board may be either single -ply or multiple -ply. Perlite thermal insulation boards shall conform to the thermal resistance prescribed. The thermal resistance, compressive strength, tensile strength, flame speed classification, and water absorption shall be tested to meet the requirements prescribed. This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date. 1. Scope 1.1 This specification covers the composition and physical properties for perlite thermal insulation board used principally above structural roof decks and as a base for built -up, modified, and elastomeric membrane roofing in building construction. 1.2 The use of thermal insulation materials covered by this specification may be regulated by building codes or other agencies that address fire performance, or both. The fire performance of the material should be addressed through standard fire test methods established by the appropriate governing documents. 1.3 The values stated in inch -pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 2. Referenced Documents (purchase separately) (D ASTM Standards http:/ /www.astm.org/Standards /C728.htm 9/15/2011 04 -02 -2012 City of Tit 0 iia Jim Haggerton, Mayor Department of Community Development PEARLLA KAESTNER PO BOX 82894 KENMOR WA 8028 RE: Permit No. D11 -353 DELI 345 ANDOVER PK E TUKW Dear Permit Holder: Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 05/30/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 05/30/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, i\A4AtiSd er Marshall Technician File: Permit File No. DI 1 -353 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 -431 -3665 ERMIT COORD COP4 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -353 DATE: 10/27/11 PROJECT NAME: DELI SITE ADDRESS: 345 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: g9in 'vision 1`d " d Public Works C, h-l-t P4\ re Prevention 1(1 ❑ Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 /01 /11 Complete Incomplete n Not Applicable n Comments: Permit Center Use Only • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/29/11 Approved ❑ Approved with Conditions ET. Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02