Loading...
HomeMy WebLinkAboutPermit D11-358 - SHIPCO - TENANT SPACESHIPCO 14900 INTERURBAN AV S Dl 1 -358 City oftukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -43 1 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 0003200009 Address: 14900 INTERURBAN AV S TUKW Suite No: Project Name: SHIPCO Permit Number: D11 -358 Issue Date: 03/06/2012 Permit Expires On: 09/02/2012 Owner: Name: SCHNEIDER LYLE D Address: C/O JSH PROPERTIES INC , 14900 INTERURBAN AVE S #130 98168 Contact Person: Name: TORJAN RONHOVDE Address: 14900 INTERURBAN AV S, #138 , TUKWILA WA 98168 Contractor: Name: BRADY MAINT & HANDYMAN SRVCS Address: 2217 E GEORGE ST , TACOMA WA 98404 Contractor License No: BRADYMH943L3 Lender: Name: Address: Phone: 206 859 -5500 Phone: 206 240 -6748 Expiration Date: 06/24/2012 DESCRIPTION OF WORK: EXPAND EXISTING TENANT SPACE INTO ADJOINING BAY. TENANT SPACE WILL BE INCREASED BY 822 SF. Value of Construction: $30,000.00 Fees Collected: $1,092.10 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11 -358 Printed: 03 -06 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: I hereby certify that I have read and : ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • whether specified herein or not. The granting of this permit does not pr e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 3 - Co- / Z Print Name: iJ C !� t� / % c� /` Pd r--1r (� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D11 -358 Printed: 03 -06 -2012 7: All construction shall be done in conforre with the approved plans and the require of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ** *FIRE DEPARTMENT CONDITIONS * ** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mrn). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 24: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) doc: IBC -7/10 D11 -358 Printed: 03 -06 -2012 26: All new sprinkler systems and all modif' ns to existing sprinkler systems shall have epartment review and approval of drawings prior to installation or ification. New sprinkler systems and all mo tions to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 27: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 29: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 30: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 31: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 32: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 33: Arty overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7110 011-358 Printed: 03 -06 -2012 CITY OF TUSILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov BuddIngTermtt; projectiNoL Date ARP11Caoncseteci -7 Date, plicatioir ges: 7M101 (For,office.use,only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax **Please Print** Site Address: 14900 interurban ave s King Co Assessor's Tax No.: 359700-0006 Tenant Name: shipco Suite Number: 215 ils:MtgiftitiVit#,T15-- 4 -' A' 0 i'1%.N.: 7.41.tj', .1„:.:00:44-: Name: 1.d. schneider & assoc. Address: Address: 14900 interurban ave s, #101 Address: City: tukwila State: wa Zip: 98168 PCONTACT4PERSON -- person'recewmtall,projec ile,A.,-wkiwzr.-aztx4.4*..,4,g , .10 -, \- communication ' - '.. . - ... . . , ...= Name: same as architect Address: City: lAriovv\A State: Zip: 01 1144 Address: Contr Reg No.: !hi/4mi AAAA1123"Eare Date: Email: torjan@ronhovdearchitects.com City: State: Zip: Phone: Fax: Email: Tdt - : -.::1.1, titi:Nt-tAttitiitiSIOttiVatreit***0?: Company Narne: fhrit Oh( hlomilx ca. Address: City: lAriovv\A State: Zip: 01 1144 Phone: Fax: Contr Reg No.: !hi/4mi AAAA1123"Eare Date: Email: torjan@ronhovdearchitects.com Tukwila Business License No.: pikc 0/1 9._<(,) HAApplicationsWotms-Applionions On Line\ 2011 Applications\ Pessoii Application Revised - 8-9-11.doex Revised: August 2011 bb New Tenant: Floor: 2 0 _Yes VI..No FotioNtooka:00-2, • '...:=_, ..,,gszteark :;,- .„.: Company Name: the ronhovde architects, llc Architect Name: torjan ronhovde Address: 14900 interurban ave south, #138 City: tukwila State: wa Zip: 98168 Phone: (206) 859-5500 Fax: (206) 859-5501 Email: torjan@ronhovdearchitects.com FotioNtooka:00-2, • '...:=_, ..,,gszteark :;,- .„.: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: 'fifirsibtitiblif*OglittirAtialffolioWeEtii;s;i101101 rti4V4 -_,_ Name: Address: City: State: Zip: Page 1 of 4 Valuation of Project (contractor's bid price): $ 30,000 Existing Building Valuation: $ 5,295,000 Describe the scope of work (please provide detailed information): Expand the existing shipco tenant space (#215) into the adjoining bay. The tenant space will be expanded by approx. 822 sf. Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. 32,000 0 0 5 -b b 25,671 822 0 5 -b b ooi ia:Se—E n VA'ccessor Attaclied:Ga�a' edeGacage 1 iiacied Carp l Defched`Cai 6— =44ir +Co"verediD�ck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) 'For an Accessory dwelling, provide the following Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: •Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11 " paper including quantities and Material Sa ety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Heahh Department. H tApplimti n .Form- Applimtions On rmel2011 Apptieetion,Waroa Application Revised - 9A- 1l.daa Revised: Angus: tot 1 bh Page 2 of 4 PEitNt T AB L%C�TION UT =ESA Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable range demonstrated. Section 105.32 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN ! "�►`.! �1 � � �' ' . � ED AGENT: Si Print Name: torjan ronhovde Mailing Address: 14900 interurban ave south, #138 Date: 11/03/2011 Day Telephone: (206) 859 -5500 tukwila wa 98168 City HAapyticat;rms1Fonm- Applications On Ime\2011 ApplicaticeraPermit Application Revised - 8- 9- 11.daa Revised: Ant 2011 bh State Page 4 of 4 • J,�.`N�' -Q wq City of Tukwila C p/ Z J Q � 190E Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.00v Parcel No.: 0003200009 Address: 14900 INTERURBAN AV S TUKW Suite No: Applicant: SHIPCO RECEIPT Permit Number: D11 -358 Status: APPROVED Applied Date: 11/03/2011 Issue Date: Receipt No.: R12 -00912 Payment Amount: $663.65 Initials: JEM Payment Date: 03/06/2012 09:40 AM User ID: 1165 Balance: $0.00 Payee: MICHAEL B FORTENBERRY, BMHS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 206798 ACCOUNT ITEM LIST: Description 663.65 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 659.15 640.237.114 4.50 Total: $663.65 doc: Receiot -06 Printed: 03 -06 -2012 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003200009 Permit Number: D11-358 Address: 14900 INTERURBAN AV S TUKW Status: PENDING Suite No: Applied Date: 11/03/2011 Applicant: SHIPCO Issue Date: Receipt No.: R11 -02408 Payment Amount: $428.45 Initials: JEM Payment Date: 11/03/2011 03:47 PM User ID: 1165 Balance: $663.65 Payee: RONHOVDE ARCHITECTS LLC PS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1089 428.45 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 428.45 Total: $428.45 doc: Receiot -06 Printed: 11 -03 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit -358 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 r, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Protest: : I occ Type o Inspection: t~, N A L Address: `• _ .. e . ��' u it 431 Da — Special Instructions: • . Date Wanted:. a.m` Requester: Phone No: 20(::, —zgo -iQ 7y ea r2I-Approved per applicable codes. Corrections required prior to approval. COMMENTS: 7c1'3,1'114,-t C6-vviub \de, i 17- ■.1/4Pover nsp ctor: Date: REINFECTION FEE REQUI ED. Prior to next inspection, fee must be paid fat 6300 Southcenter Bl .. Suite 100. Call to schedule reinspection. INSPECTION RECORD • Retain a copy' with permit t . -_35:S.� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 . (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 h- Project: h11£0 i T SS — t---I 1 A Type of Inspection: .yli‘.)42) 6-,1.AZ IrJt' — tJ)• Address: ` 1'-lg00 3Ni°dbLd13 Date Called: N`�� Special Instructions: Date Wanted: (a.m. - e 1- 1 -2 p.m. Requester: Pholnet :f , L4/V_ 6,7 /Q - Approved per applicable codes. a Corrections required prior to approval. r COMMENTS: i T SS — t---I 1 A 6-,1.AZ IrJt' — tJ)• :9 Date: I sp ctor: nAtt. -A-, 1 pi INSPECTION FEE REQUI D. Prior to next inspection. fee must be ai at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r INSPECTION RECORD Retain a copy with permit INSPECT ON O. PERMIT NO. bu 3Sk CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 re._ (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: kw / Type f.1nspectiont Address: _ 120a .!A1`` TJr P/ Date Called: Special In tructions: • 0 S -2 ,,Q Date Wanted: . Requester: - Phone No: 24q _' 7 pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 3 ri REINSPECTION FEE REQUIRED. rior o next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. - Cip INSPECTION NUMBER . -.r• ,. • - - - INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: - Type of Ins ection: t_ � \Q-� tvn.9 ,,,, \—‘C C∎, L Address: /4-D -M., A .5 Suite #: z. z.--0 Contact Person: r Monitor: A�a'v, (sk, -.k--cc F o c - ev,\g‘.c r-,r Special Instructions: Phone No.: CR Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: ..z_5 - 5,,,.,;16, ■rc. Fire Alarm: -s o Hood & Duct: Monitor: A�a'v, (sk, -.k--cc Pre -Fire: Permits: Occupancy Type! c� •,, +fi'''t'.. �k� F\:� G� b�� l J — . Needs Shift Inspection: >No Sprinklers: ..z_5 - 5,,,.,;16, ■rc. Fire Alarm: -s o Hood & Duct: Monitor: A�a'v, (sk, -.k--cc Pre -Fire: Permits: Occupancy Type! Inspector:S 1 Date: Q 3‘t \ Z Hrs.: } $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 tea. - . �. •fy. .. - : aam� r ... !'� • . r} Y...r, .y �. • 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Of/ - 3 r' // S- 2 S-t/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: Si) .'p c a Sprinklers: Type of Inspection: 54.0,- ,‘ a /L /.t.� %ro+-'1"- • Address: /'/9o) Suite #: 2240 I pq s Contact Person: . 7/ In Permits: Special Instructions: Phone No.: 2s3 - 9Z — IN•o Approved per applicable codes. Corrections required prior to approval. COMMENTS: Die IT, k Needs Shift Inspection: ' Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 0.745- k Date: .3/3 ,1/ z_ Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from fhe City of Tukwila Finance Department. Call to schedule a reinspection. Billing Ad_ ress • Attn: 1 Company Name: Address: City: State: Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 • • 08 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director TORJAN RONHOVDE 14900 INTERURBAN AV S, #138 TUKWILA WA 98168 RE: Permit No. D11 -358 SHIPCO 14900 INTERURBAN AV S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 09/09/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 09/09/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marsh Tec1 nisi File: Permit File No. D11 -358 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206 - 431 -3665 1 HERMIT COORD COPY PLAN REVIEW /ROUTI6VG SLIP ACTIVITY NUMBER: D11 -358 DATE: 11/03/11 PROJECT NAME: SHIPCO SITE ADDRESS: 14900 INTERURBAN AV S. STE 215 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: Air , rt /C 1\ ik Lng Division Fire Prevention a Planning Di Pik n ,,vb d3 is o Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Usi, Incomplete n DUE DATE: 11 /08 /11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route ly■1 Structural Review Required n REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 /06 /11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pifer Friendly Page s General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BRADY MAINT & HANDYMAN SRVCS UBI No. 601607822 Phone 2062406748 Status Active Address 2217 E George St License No. BRADYMH943L3 Suite /Apt. License Type Construction Contractor City Tacoma Effective Date 6/23/2006 State WA Expiration Date 6/24/2012 Zip 98404 Suspend Date County Pierce Specialty 1 General Business Type Individual Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date FORTENBERRY, MICHAEL B Owner 06/23/2006 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC INS CO YLI261380 06/23/2006 Until Cancelled $12,000.00 06/23/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Liberty Northwest Ins Corp BKS53514602 06/23/2011 06/23/2012 $1,000,000.00 04 /29/2011 3 LIBERTY NORTHWEST INS CORP 5H053514602 06/23/2010 06/23/2011 $1,000,000.0005 /17/2010 2 OHIO CAS BH053514602 06/23/2008 06/23/2010 $1,000,000.0006 /03/2009 1 OOHIO CAS INS BH052490248 06/23/2006 06/23/2008 $1,000,000.0005 /21/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: // fortress .wa.gov /lni/bbip/Print.aspx 03/06/2012 =BO flhj tuna la111�. Wu REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION 6625 S. IclOth St. Suite B -105 KENT, WASHINGTON gSO32 (425) 656 -0500 FAX (425) 656 -0501 ronhovdearchitects.com - •4344" TO'R -JAN RONNOVDE STATE OF WASHINGTON 10 5 co co I— Z cc O a_ t co (7) < Z ac w s 111 0 OCL CO bl\ 6 RECEIVED nay OF TI IKIMLA 3 Nrn�n32011 PER r&T' CENTER 2 10/31/2011 PERMIT SUBMITTAL NO. DATE DESCRIPTION REVISIONS SHEET CONTENTS: SITE PLAN PROJECT NOTES LEGAL DESCRIPTION JOB NO.: 2001.01Y DRAWN BY: DNS CHECKED BY: TJR DATE: 10/31/11 SHEET NO. CS PROJECT INFO ABBREVIATION SNOTE Giarif with Architect alI abbreviations not Ilsted. �� �$ ;S44 c0 _ w , ID ,, . - ' it - . 111,, BLDG. OWNER: L.D. SGHNEIDER AND ASSOCIATES 14100 INTERURBAN AVE. 5. TUKWILA, WA 18168 (206) 243 -8123 REP KURT SCHNEIDER EXISTING BUILDING INFO: I 00 INTERURBAN URBAN AVE. 5., #215 PROJECT ADDRESS: 41 ER A , TUKWILA, WA 18168 CODE OF CONSTRUCTION: 200q IBC (NEW WORK ONLY) OGG. TYPE: (B) OFFICE ZONING: RCM SITE AREA 165,338 SF (3.8 AG PER KGR) , CONSTRUCTION TYPE'S 3 -6 SPRINKLED BUILDING AREA: 51,611 SQ. FT. TENANT IMPROVEMENT AREA THIS APPLICATION: 3,340 50. FT. AB. ANCHOR BOLT I.D. INSIDE DIAMETER AGT ACOUSTICAL CEILING TILE INSUL. INSULATION A.F.F. ABOVE FINISHED FLOOR INT. INTERIOR ASGR: AGGREGATE AL. ALUMINUM JAN. JANITOR ALT. ALTERNATE JNT. JOINT T JOINT APPROXAPPROXIMATE J5 T. ARCH. ARCH ITEGTURAL KIT. KITCHEN BD. BOARD BLDG. BUILDING LAB. LABORATORY BLK BLOCK LAM. LAMINATE { BLK G. BLOCKING LAY. LAVATORY BM. BEAM BOT. BOTTOM LT. LIGHT SINN. BETWEEN MAX. MAXIMUM B.U.R. BUILT UP ROOFING MEGH. MECHANICAL B.W. BOTH WAYS MEMB. MEMBRANE mC9 — j ` \' \ CR . �EiV 41 ��R •_. _..� CINf • `� OF ��/ PPP J E C T �� M— z ,4,. O �, N 21'24'03° pp -_ F� III — � I I I I ,.C8 I f ������.� 1 1 1 1 ' 1 1 OC . n ; ` . of Sco�.. : :,: , ,00141D-FLOOR • N -_ ' -, 1s.00 , ` �---- '•------ "" ��- .. ' -- ,. WEST LINE '� � -• _ . . • - . — — • — • _ • . _ . _ .,� -�__ .._.._ �`.._.._.._.._..- 4'03■ dM ,15815..0' _ .._.. -• _ . _ .. _ / ' JRBAIJ RR 60', w e � � M — — _ _ _ _ "` --- -- -- - - - = - -- - .. _ - .._.._:._.._.._ ._.. — ._. - M fil111 I �\' &1� '' - TW0 STOREY MA STRUCTURE �';� ^ o 'Y AND STEEL . — ®C9 (� -- .C6 - -- t I 1 . - F t t I I - I 1 - -_ t ill _ I � ���f �t I - -- - -- -__ _ `� '• � .� ' �• i° m - ��� � 1 - �-� Q -2. _ 892 +46.90 mce mce / 235.09 co ° _ — 2•' z A) - 87.44' __._ tgb" ' 24's . 0 T5 — 5t ,t {r MFR. MA G.J. CONTROL JT. M.F. MA1HOLE 1UFAGTURER - - = _ - �.. o L =zs /' ' GLG. CEILING a - :-.o ecr— GLKG. CAULKING M GLR. CLEAR M.O. G.M.U. CONCRETE MASONRY UNIT MTL. N. M1tANEOUS MASONRY METAL OPENING - - _ 1370.21' _ _ o o= or48'2s^ - - - - - - - - - N 21'23'30" W 2314.13' MEA. (2314.07' ROS "A) PE E . INTERURBAN AVENUE S. a D ---------------- COL. COLUMN MUL. MULLION GONG. CONCRETE GONN. CONNECTION N NORTH CONSTR. CONSTRUCTION N.I.G. NOT IN CONTRACT CONT. CONTINUOUS NO NUMBER G.T. CERAMIC TILE NOM. NOMINAL DEG. DEGREE N.T.S. NOT TO SCALE DET./DTLDETAIL 0.G. ON CENTER D.F. DRINKING FOUNTAIN O.D. OUTSIDE DIAMETER DIAL. DIAGONAL OH. OVERHEAD DIA3ie DIAMETER OP: OPENING DOWN P PSE DS. DOWNSPOUT DWG. DRAWING E EAST PCT. PRE -CAST P.L. PROPERTY LINE (E) EXISTING P.LAM. PLASTIC LAMINATE (E) EACH PLAS. PLASTER E.J. EXPANSION JOINT PLYWD. PLYWOOD E.I.F.S. EXTERIOR INSULATION AND PR. PAIR FINISH SYSTEM EL. ELEVELEVATION Q.T. QUARRY TILE ELEC. ELECTRICAL ELEV. ELEVATION R. RISER EMER EMERGENCY R.D. ROOF DRAIN ENGL. ENCLOSURE RE: REFER TO ... EQ. EQUAL REFR. REFRIGERATOR EQUIP. EQUIPMENT REINF. REINFORCED E.W. EACH WAY REQ. REQUIRED E.W.G. ELECTRIC WATER COOLER RM ROOM EXP. EXPANSION R.O. ROUGH OPENING EXT. EXTERIOR 5 SOUTH F.A. FIRE ALARM 5.G. SOLID GORE F.D. FLOOR DRAIN SCHED. SCHEDULE F.D.G. FIRE DEPARTMENT GONN. 5ECT. SECTION FOOT ION FDN. FOUNDATION S.F. SQUARE F.E. FIRE EXTINGUISHER 5HT. SHEET F.E.G. FIRE EXTINGUISHER CABINET SIM. SIMILAR F.F. FINSH FLOOR SPEC. SPECIFICATION F.H.G. FIRE HOSE CABINET 50. OR q SQUARE FIN. FINISH 5.5. STAINLESS STEEL F.L. FLOW LINE STAGG. STAGGERED FLR. FLOOR STD. STANDARD FLUOR. FLUORESCENT STIFF STIFFENER FNS. FOUNDATION STL. STEEL F.O.B. FACE OF BRICK STRUG. STRUCTURAL F.O.G. FAGS OF CONCRETE SUSP. SUSPENDED F.S. FULL SIZE FT. FOOT OR FEET TR TREAD FIG. FOOTING T 4 B TOP AND BOTTOM FURR. FURRING TER. TERRAllO T � Si TONGUE � GROOVE GA. GAUGE THK. THICK GALV. GALVINIZED T/ TOP OF G.G. GENERAL CONTRACTOR TYP. TYPICAL G.L. GLASS 6R. GRADE U.O.N. UNLESS OTHERWISE NOTED GYP. GYPSUM GYP. BD.GYPSUM BOARD TILE VCT VINYL COMPOSTION L VER VERIFY H.B. HOSE 516B VERT. VERTICAL H.G. HOLLOW GORE H/G HANDICAPPED W WEST HDWD. HARDWOOD W/ WITH HDWE. HARDWARE H.M. HOLLOW METAL W.G. WATER CLOSET HR. HOUR WD. WOOD HT. HEIGHT W/0 WITHOUT HYAG HEATING, VENTILATION AND AIR CONDITIONING PLATE i� PLATE V E T INDEX �, G5 COVER SHEET / SITE PLAN AGI.I CODE REVIEW AND EXISTING PLAN AI.I FLOOR PLAN AND SCHEDULES .:�- A8.1 CEILING PLAN A1l.I DETAILS NTS D� ARC HITECTURAL SYMBOLS OWNER/CONTRACTOR COORDINATION NOTES LEGAL DESCRIPTION ��R - 55'1100 -0006 is ' _ �, SECTION: Q, EXTERIOR ELEVATION: THE FOLLOWING NOTES SHALL SERVE A5 A GUIDE TO THE CONTRACTOR TO VERIFY EACH CONDITION EITHER THE PRODUCT MANUFACTURER OR SUPPLIER, AND /OR LOCAL JURSDICT'ONS FOR THEIR REQUIREMENTS PRIOR TO SUBMITTING A BID TO THE OWNER OR PROCEEDING WITH THEIR WORK. THE ITEMS OUTLINED BELOW ARE NOT INTENDED TO BE AN EXHAUSTIVE ANALYSIS OF ALL POSSIBLE AREAS OF CONCERN OR CONFLICT, BUT RATHER TO SERVE AS A BEGINNING POINT IN IDENTIFYING COMMONLY OVERLOOKED AREAS IN THE CONSTRUCTION PROCESS. I• REVIEW MANUFACTURERS PRODUCT LITERATURE AND GENERAL NOTES FOR INSTALLATION. INSTRUCTIONS UNIQUE TO THE PROJECT CONSTRUCTION TYPE A. RECEPTACLE BOXES (I.E. T.V., TELEPHONE, ELECT., PLUMBING) 2. REVIEW LOCAL JURISDICTION REQUIREMENTS FOR COMPLETE INSTALLATIONS OF THE FOLLOWING : A. FIRE SPRINKLER SYSTEM B. MANUAL 4 AUTOMATIC FIRE ALARM SYSTEM AS REQUIRED G. FIRE EXTINGUISHER SIZE AND LOCATION 3. COORDINATE WITH THE FOLLOWING UTILITIES AND COMPLY WITH LOCAL JURISDICTIONAL REQUIREMENTS. TELEPHONE : GABLE T.V. UTILITY : POWER UTILITY (VAULT REQUIREMENT - EASEMENTS) : TRASH SERVICE : WATER UTILITY : 4. THE FOLLOWING ITEMS SHALL BE BIDDER DESIGN SYSTEM. THE CONTRACTOR SHALL PROVIDE A COMPLETE SYSTEM TO THE OWNER AND BUILDING DEPARTMENT WHICH COMPLIES WITH ALL JURISDICTIONAL REQUIREMENTS. A. BUILDING AND 5I TE ELECTRICAL B. HVAC SYSTEM (HEATING ONLY) C. PLUMBING SYSTEM REVISIONS No chap Qes shaft k,o mado t o the sco' of uvor;k i� ►itho oval tit prior G,p�r of T ta��t�dit Building o Division. :on,, will r q� a new ! e giro and may include additional plan man submittal p n revr,,w fees. PARCEL A: THAT PORTION OF TRACT I OF INTERURBAN ADDITION TO SEATTLE, ACCORDING TO PLAT RECORDED IN VOLUME 10 OF PLATS AT IN KING COUNTY WASHINGTON LYING SOUTHERLY OF A PAGE(5) 55, , LINE WHICH EXTENDS NORTHEASTERLY, PERPENDICULAR WITH THE WESTERLY LINE OF SAID TRACT, FROM WHICH A POINT ON SAID WESTERLY LINE WHICH 15 685 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT, AND LYING NORTHERLY OF A LINE WHICH EXTENDS .NORTHEASTERLY, PERPENDICULAR WITH THE WESTERLY LINE OF SAID TRACT, FROM A POINT ON SAID WESTERLY LINE WHICH 15 1556 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT: ALSO THAT PORTION OF THE VACATED PUGET SOUND ELECTRIC RAILWAY RIGHT -OF -WAY LYING SOUTHEASTERLY OF SOUTH I41th STREET, AS CONVEYED BY PUGET SOUND POWER AND LIGHT COMPANY TOTHE CITY OF TUKWILA BY DEED DATED OCTOBER 25,1165 AND FILED UNDER RECORDING NO. 655 -163q AND LYING NORTHWESTERLY OF A LINE WHICH EXTENDS SOUTHWESTERLY, PERPENDICULAR WITH THE EASTERLY LINE OF SAID PUGET SOUND ELECTRIC RIGHT -OF -WAY WHICH 15 ALSO THE WESTERLY LINE OF SAID TRACT I, INTERURBAN ADDITION, FROM A POINT ON SAID WESTERLY LINE WHICH 15 1565 FEET SOUTHEASTERLY FROM THE NORTHWEST CORNER OF SAID TRACT; EXCEPT ANY PORTION THEREOF LYING WITHIN 5R 181. PARCEL B: IN THE SOUTHEAST QUARTER OF THE NORTHEAST QUARTER OF SECTION 23, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M., IN KING COUNTY, WASHINGTON, THOSE PORTIONS, IF ANY, OF TRACT I OF INTERURBAN ADDITION TO SEATTLE, ACCORDING TO PLAT RECORDED IN VOLUME 10 OF PLATS AT PAGE(5) 55, IN KING COUNTY WASHINGTON; AND OF VACATED PUGET SOUND ELECTRIC RAILWAY RIGHT -OF -W AY ADJOINED THERETO ON THE WEST, LYING SOUTHERLY OF A LINE DRAWN PERPENDICULAR TO THE WEST LINE OF SAID TRACT I AND LYING 1565 FEET SOUTHEASTERLY FROM 0 SECTION LETTER D ELEVATION LETTER SHEET NUMBER SHEET NUMBER ENERGY CODE; RECAP p DETAIL: INTERIOR ELEVATION: - LIGHTING: m DETAIL NUMBER e ELEVATION LETTER I) SEE SHEET AB.I FOR RECAP SHEET NUMBER i DOOR NUMBER EQUIPMENT NUMBER - BUILDING SHELL I) ALL BUILDING SHELL INSULATION 15 EXISTING 4 UNCHANGED. 1 i WINDOW TYPE O •• ELEVATION TAG SHEET LAYOUT DESIGNATION 102.5 PROJECT DESCRIPTION PROJECT VALUATION : $ 30,000 BUILDING VALUATION: $5,215,000 (PER KGR) VACANT LEASING SPACE EXPAND EXISTING OFFICE INTO ADJACENT VACANT OFFICE SPACE. TENANT 215 WILL BE EXPANDED BY APPROX 822 5F ACCESSIBILITY COMPLIANCE VIEW NUMBER SPOT ELEVATION ® SHEET NUMBER a REVISION ® 12 COLUMN GRID I CENTER LINE _ I CONTOUR LINE PROPERTY LINE NEW CONTOUR LINE 21 �42i EXISTING , ., NORTH DESIGNATION I) BUILDING SHELL 4 PARKING AREAS ARE EXISTING. ALL TENANT SPACES ARE ACCESSIBLE BY AN ACCESSIBLE ROUi"E FROM THE PARKINS AREAS. 2) ALL DOOR HARDWARE TO BE LEVER TYPE 3) ALL TOILETS ARE EXISTING. N0 NEW HG ACCESSIBLE TOILETS ARE REQ'D PER WAG 51 -10 I I" DN. g , �a� n ���,? ��..,. „ -.w, GRAPHIC SCALE CHANGE IN ELEVATION S ROOF SLOPE INDICATION - cE :'Pip. ,I F ���'` "`' � -'' G I f: -� i��iT ,� #�f ��: ".� E�•�Q, �� -��tr I.u� FOR: 1• ���VchanrCG) iectrica► Piumbin 9 as Piping 9 City of Tukwaa Ct,t i_ igUG DIVISION - VICINITY A P � L4 . , „` tY, �OOm �� \ ;�_r� � THE NORTHWEST CORNER THE WEST LINE THEREOF; FOR ROAD. OF EXCEPT SAID TRACT AS MEASURED ALONG ANY PORTI PORTION THEREOF TAKEN'`" . `}� � :f � � • At ».. ¢ 149th.. tlOft " Fof Y �'t >��� pJ.,..+ review approval Is subject to errors and om dons. �;;_ k:ql of construction documents does not aUfhGrIZB �:, 11,. ., ;'' f ''. adopted code or ordnance. Rec*✓ t .:�:,.::lt'tl �, s:°t� � p# � { 1approve FI ICI CCpj/and 1S acknowledged: 151st ;� h �� � , � �► � `,,��� B' Y,�/ - � Date: . r 7 �..- tS1 # S 158rd City l7 Tukwila BUILDING DIVISION P. . � � 2001 MaDQuasi•com. Inca 02001 Navioatlon Technoboie rt 6625 S. IclOth St. Suite B -105 KENT, WASHINGTON gSO32 (425) 656 -0500 FAX (425) 656 -0501 ronhovdearchitects.com - •4344" TO'R -JAN RONNOVDE STATE OF WASHINGTON 10 5 co co I— Z cc O a_ t co (7) < Z ac w s 111 0 OCL CO bl\ 6 RECEIVED nay OF TI IKIMLA 3 Nrn�n32011 PER r&T' CENTER 2 10/31/2011 PERMIT SUBMITTAL NO. DATE DESCRIPTION REVISIONS SHEET CONTENTS: SITE PLAN PROJECT NOTES LEGAL DESCRIPTION JOB NO.: 2001.01Y DRAWN BY: DNS CHECKED BY: TJR DATE: 10/31/11 SHEET NO. CS T H E RONHOVDE ARCHITECTS C 6625 5. IciOth 5t. Suite 6-I05 KENT, WASHINGTON f:032 (425) 656-0500 • FAX (425) 656-0501 ronhovclearchVcts.com WORST CASE TRAVEL DISTANGE • =206' FEET < 300 FEET PER TABLE 1016.1 TIT SUITE 208 EXIT • HORST CASE COMMON PATH OF \ 0 1 TRAVEL DISTANCE = 26' FEET < 100 1 FEET PER 10143 •••••■=0. 1 n 1 -J TENANT LOCATION SUITE it215 I— co CC co 0 Z fl 0 • co (7) < Z Z < < < 0 0_ GENERAL CODE AND EXITING NOTES NET TENANT AREA PER 502.1 = 3,340 5F OCCUPANT LOAD PER TABLE 1004.1.1 = 33 EXITS REQUIRE]) FROM TENANT- SPACE PER TABLE 10I c1.2 = 1, PROVIDED = 2 EXITS REQUIRED FROM BOILDIVG: 3, PROVIDED: 3 EXIT PROTECTION REQUIRED PER 1011.I 4 : NO EXIT SIGNAGE REM) PER 10111.1: NO EXIT ILLUMINATION REG1119 PER1006.1: ONLY WHEN mum 15 OCCUPIED EXIT EMERGENCY ILLUMINATION REM) PER 10063: NO PER 1006.3.2 BUILDING SHELL 15 EQUIPPED NITH EXIT ILLUMINATION AND EMERGENCY EXIT SIGNAGE. BUILDING SHELL 15 EQUIPPED NITH PANIC DEVICE HARDWARE ON ALL EXIT DOORS. 10 10/31/2011 PERMIT SUBMITTAL REVIEWED FOR CODE. COMPLIANCE APPROVED NO. DATE REVISIONS DESCRIPTION City of Tukwila BUILDING • DIVISION iitGEIVED TV OE TUKWILA (9111/Oi 2011 PERMIT CENTER SHEET CONTENTS: CODE REVIEW JOB NO.: 2001.01Y • DRAWN 13Y LIA1S CHECKED BY, TJR DATE: 10/31/11 SHEET NO. AC1.1 >< TIT SUITE 208 EXIT • HORST CASE COMMON PATH OF \ 0 1 TRAVEL DISTANCE = 26' FEET < 100 1 FEET PER 10143 •••••■=0. 1 n 1 -J TENANT LOCATION SUITE it215 I— co CC co 0 Z fl 0 • co (7) < Z Z < < < 0 0_ GENERAL CODE AND EXITING NOTES NET TENANT AREA PER 502.1 = 3,340 5F OCCUPANT LOAD PER TABLE 1004.1.1 = 33 EXITS REQUIRE]) FROM TENANT- SPACE PER TABLE 10I c1.2 = 1, PROVIDED = 2 EXITS REQUIRED FROM BOILDIVG: 3, PROVIDED: 3 EXIT PROTECTION REQUIRED PER 1011.I 4 : NO EXIT SIGNAGE REM) PER 10111.1: NO EXIT ILLUMINATION REG1119 PER1006.1: ONLY WHEN mum 15 OCCUPIED EXIT EMERGENCY ILLUMINATION REM) PER 10063: NO PER 1006.3.2 BUILDING SHELL 15 EQUIPPED NITH EXIT ILLUMINATION AND EMERGENCY EXIT SIGNAGE. BUILDING SHELL 15 EQUIPPED NITH PANIC DEVICE HARDWARE ON ALL EXIT DOORS. 10 10/31/2011 PERMIT SUBMITTAL REVIEWED FOR CODE. COMPLIANCE APPROVED NO. DATE REVISIONS DESCRIPTION City of Tukwila BUILDING • DIVISION iitGEIVED TV OE TUKWILA (9111/Oi 2011 PERMIT CENTER SHEET CONTENTS: CODE REVIEW JOB NO.: 2001.01Y • DRAWN 13Y LIA1S CHECKED BY, TJR DATE: 10/31/11 SHEET NO. AC1.1 WALL TYPE LEGEND EXISTING WALL TO REMAIN NEW 3 I /2 ", 25 GA. METAL STUD @ I6" OG WALL TENANT WALL. RUN TO EXISTING CEILING. PER DETAIL 5 /AII:I. NON- BEARING EXISTING WALL TO DEMO SYMBOL. LEGEND O EXISTING JUNCTION BOX (rn DUPLEX OUTLET DUPLEX OUTLET MOUNTED ABOVE BACKSPLASH 4 -PLEX OUTLET iii IMF DUPLEX TELEPHONE/DATA OUTLET (DI DATA OUTLET I: FILL IN EXISTING DOOR 4 WINDOW 8`- 51/2" ALIGN W/ EXIST WALL • FILL IN EXISTING DOOR FILL IN EXISTING WINDOW T 1 4•• ••• rL. OFFIGE III ELEG 11 11 11 ROOM FINISH NO. FINISH SCHEDULE BASE NOTES: I. ALL EXISTING FINISHES TO REMAIN 2. EXISTING ENTRY TILE TO REMAIN 3. EXISTING GEILING GRID TO REMAIN 4. REPAINT 5. REGARPET b. INSTALL NEW AGT REMARKS a OFFICES GONG GPT. GIB PT AGT FAG q' -0" 3,4,5 BREAK GONG JV ACT FAG' GI' 011 3,4,6 ROOM FINISH LEGEND FLOOR WALLS GONG. GONGRETE PT EXP EXPOSED GONGRETE PT 5V SHEET VINYL, ARMSTRONG IMPERIAL TEXTURE. STANDARD EXGELON, 51839 FORTRESS WHITE TILE VGT VINYL COMPOSITION TILE MR TILE TILE GWB GPT CARPET BASE RB COVE TILE WOOD 4" RUBBER BASE, ROPPE BLACK 6" SHEET VINYL (COVED) 4" TILE BASE 4" WOOD BASE CEILINGS AGT EXP GWB PAINT 48" PLASTIC LAMINATE WAINSCOT AT WET WALLS 4 WITHIN 2 FT OF FIXTURES 48" TILE AT WET WALLS 4 WITHIN 2 FT OF FIXTURES MOISTURE RESISTANT GYPSUM HALL BOARD ACOUSTICAL TILE (SUSPENDED) EXPOSED STRUGTURE GYPSUM WALL BOARD cv 0 OFFICE 11 Ir© BREAK 1 0 ELEG e - OFFIGE u @1 OFFIGE r 0 LOFFIGE `J. FL r -I FLOOR PLAN SCALE: 1/4" = I' -0" ALL DIMENSIONS TO FAGE OF STUD UNLESS NOTED OTHERWISE 1 11 1 0 ELEG OFFICE EX -3 n 0 DOOR AND FRAME SCHEDULE MARK TYF E MAT'L. FINISH NOMINAL SIZE WIDTH HEIGHT DEPTH MATL. FINISH EX -1 WOOD STAIN 3' 1/3/4" EX-2 WOOD STAIN 3' EX -3 WOOD STAIN I/3/4" WOOD STAIN 1/3/4" 5T GENERAL DOOR NOTES -ALL INTERIOR AND EXTERIOR DOORS NOTED SHALL HAVE LOCKS PROVIDED W/ HARDWARE THAT 15 READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE U5E OF A KEY OR SPECIAL KNOWLEDGE PER IBC 1008.1.8 -ALL HARDWARE PULLS, ,HANDLES, LOCKS, LATCHES OR OTHER OPERATING DEVICES SHALL NOT REQUIRE TIGHT GRASPING, PINGHING OR TWISTING OF THE WRIST TO OPERATE PER IBC 10082.1 -ALL EXTERIOR DOORS TO BE EQUIPPED WITH THRESHOLDS WITH A MAXIMUM RISE OF 1/2' PER ANSI 404.2.4. -ALL DOORS IF NOT SPECIFICALLY NOTED OTHERWISE SHALL BE PROVIDED WITH HG LEVER HANDLE HARDWARE COMPLYING WITH ANSI 4042.6. -ALL HARDWARE TO BE MOUNTED WITH OPERABLE PARTS LOCATED BETWEEN 34" AND 48" ABOVE THE FLOOR PER ANSI 404.2:6. PANIC AND FIRE EXIT I IARDWARE SI IALL BE rROVIDED ON ALL DOOR. W/ LOGKC AND LATGI ICS PER IBG 1008.1.1. -DOOR CLOSERS SHALL BE ADJUSTED 50 THAT FROM THE OPEN POSITION OF 610 DEGREES, THE TIME REQURIED TO MOVE THE DOOR TO AN OPEN POSITION OF 12 DEGREES SHALL BE 5 SECONDS MINIMUM 1 11 OFFICE 11 0 0 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 15 2011.. City of Tukwila BUILDING DIVISION' NOTES: I. EXIST. LOCKING DOOR TO SUITE TO REMAIN 2. EXIST 5I -FOLD TO REMAIN 3. EXISTING DOOR TO REMAIN AS 15. UPGRADE TO LEVER HANDLE HARDWARE IF NOT PRESENT. 4. BUILDING STANDARD INTERIOR DOOR. PROVIDE LEVER HANDLE LOGKSET 5 DOOR TO BE RELOCATED /TEMPERED PLASS DOOR RECEIVED B CITY OF TUKIMLA NOV 032011 PERMIT CENTER TYPES T H E FONHO V DE ARCHITECTS C 6625.5. IciOth St. Suite, B -105 KENT, V' ASH I NGTON 88032 (425) 656 -0500 ■ FAX (425) 656 =0501 ronhovdearchit- cts.c m ,344 �R -JAN "ONHOVDE. STATE OF WASHINGTON bii 3s8 10 8 1 6 5 4 3 2 I 10/31/2011 NO. DATE REVISIONS PERMIT SUBMITTAL DESCRIPTION SHEET CONTENTS: FLOOR PLAN JOB NO.: 2001.OgY DRAWN BY: LW5 CHECKED BY: TJR DATE: 10/31 /11 SHEET NO. Ai.1 LIGHTING LIGHTING ENERGY GALG. PER MEG 2001 EDITION TABLE 15 -1 USE: OFFICE BUILDING COMPLIANCE METHOD: PRESCRIPTIVE NET AREA: 3340 5F NOTES SUSPENDED CEILING AT 9' -0" AFF RELOG.TE EXISTING FIX1 5U5PE DED GELLING AT V -0" AFF RE SUSPENDED CEILING AT 9' -O" AFF PER MEG 2009 SECTION 11323 WHERE LESS THAN 60 PERCENT OF THE FIXTURES IN A SPACE ENCLOSED BY WALLS OR CEILING HEIGHT PARTITIONS ARE NEW, THE INSTALLED LIGHTING WATTAGE SHALL BE MAINTAINED OR REDUCED. THERE 15 NO CHANGE TO THE NUMBER OF PROPOSED FIXTURES RELOCATE FIXTURES AS NOTED PER PLAN: EXISTING. LIGHT FIXTURE DEMO LIGHT FIXTURE X RELOCATED LIGHT FIXTURE 11 11 11 11 11 REFLECTED CEILING PLAN NOTE: SUSPENDED CEILING GRID 15 EXISTING. INSTALL NEW CEILING LAY -IN PANELS. MATCH BUILDING STANDARD. HVAG SUPPLY AND RETURN REGISTERS ARE EXISTING. VERIFY LOCATIONS WITH NEW LIGHT FIXTURES AND RELOCATE AS NECESSARY: FIRE SPRINKLER HEADS ARE EXISTING. VERIFY LOCATIONS WITH NEW LIGHT FIXTURES AND RELOCATE AS NECESSARY. ADJUST HEAD LOCATIONS IF NECESSARY FOR CODE MANDATED CLEARANCE OR COVERAGE. SUSPENDED CEILING AT '-0" AFF b I V-- 3: REVIEWED FOR CODE COMPLIANCE APPROVED NOV 15`2011 City of Tukwila BUILDING DIVISION RECEIVED C1TV OF TUKVUILA NOV 0 3 2011 PERIVI1T CENTER T H E RONHOVDE DE ARCHITECTS L C 6625 S. IciOth St., Suite B -105 KENT, WASH I NOTON q 8032 (425) 656 -0500 ■ FAX (425) 656 -0501 ronhovdearch itects.com RONHOVDE WASHINGTON 10 10/31/2011 PERMIT SUBMITTAL NO. DANE DESGRI PT ON REVISIN: SHEET CONTENTS: REF. CEILING PLAN. JOB NO.: DRAWN BY: CHECKED BY: DATE: 2001.0c1Y LW5 TJR 10/31/11 SHEET NO. A8.1 SEE WALL TYPE SCHEDULE ALUM. BREAKSHAPE TO MATCH GLAZING SYSTEM FINISH SEALANT BEAD GLAZING MULLION T H E RONHOVDE ARCHITECTS C 6625 S. IclOth St. Suite B -105 KENT, 1NA5H I NGTON (18032 (425) 656 -0500 • FAX (425) 656 -0501 ronhovdearGhitects.com -JAN ONHOVDE E OF WASHINGTON WALL 0 GLAZING MULLION SCALE 3" _ 1 '_0.. IAIMM -I psi ram ermarAirmri -1/4" GLASS (SEE PLAN FOR SAFETY 4 EIRE REQUIREMENTS I/2 "x1 -1/2" TRIM 3/4" JAMB 1/2 "x1 -1/2 TRIM METAL STUDS SEE WALL TYPES F•-• z w WON � a w INTERIOR WINDOW DETAIL SCALE 3" _ lWWJ -1 DOOR PER SCHEDULE: 1/2 x2-1/2" TRIM METAL STUDS SEE WALL TYPES • REVIEWED fry,.' CODE. COMPLIANCE • APPROVE) NOV 15 2011 City of Tukwila BUILDING DIVISION DOOR JAMB. SCALE 3" = (HEAD SIMILAR) 7DMJ -4 10 -METAL STUDS CONNECTED TO ROOF STRUCTURE AT 8' -0" O.C. MAX. SUPPORTS ATTACHED DIRECTLY TO TOP PLATE OF WALL THROUGH OPENING IN SAG SEE WALL SCHEDULE. 1 -1/4" RAM -SET GONG. PINS @ 24" 0.C. 10/31/2011 GONG. FLOOR NO. DATE PERMIT SUBMITTAL DESCRIPTION REVISIONS SHEET CONTENTS: DETAILS WALL / FLOOR CONNECTION 2F5 -1 JOB NO.: 2001.O6Y DRAWN BY:. L1A15 CHECKED BY: TJR DATE: 10/31/11 RECEIV A CITY OF TLI�VIIILA NOV 0.32011 PERMIT CENTER SHEET NO. A1i.1