Loading...
HomeMy WebLinkAboutPermit D11-362 - 17250 BUILDING - VANILLA SHELLVANILLA SHELL 172500 SOUTHCENTER PY Di 1-362 City o*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7888920020 Address: 17250 SOUTHCENTER PY TUKW Suite No: Project Name: VANILLA SHELL Permit Number: D11 -362 Issue Date: 12/01/2011 Permit Expires On: 05/29/2012 Owner: Name: WIG PROPERTIES LLC -SS Address: 4811 134TH PL SE , BELLEVUE WA 98006 Contact Person: Name: GREG EDWARDSON Address: 4811 134 PL SE , BELLEVUE WA 98006 Phone: 253 - 686 -6277 Contractor: Name: OWNER AFFIDAVIT - MON WIG Phone: Address: Contractor License No: Expiration Date: DESCRIPTION OF WORK: INTERIOR FINISHES TO EXISTING 1896 SQ FT. ADD ONE RESTROOM, ELEC, DROP CEILING Value of Construction: $35,000.00 Fees Collected: $1,215.02 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11-362 Printed: 12 -01 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Start Time: N Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: 1)---(- / I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to vio •- or cancel the provisions of any other state or local laws regulating construction or the performance of work. I • • authorized to si• y:: d obtain this development permit and agree to the conditions attached to this permit. Signatur:. ��� ��� / Date: /Z" Print Name: Cp le)Cro 75:b610- (kbS l'( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11-362 Printed: 12 -01 -2011 this requirement. 7: There shall be no occupancy of a building until final inspection has been completed and approved oved by Tukwila building inspector. No exception. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one -third and lower one -third of the water heater's vertical dimension. A minimum distance of 4- inches shall be maintained above the controls with the strapping. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 13: ** *FIRE DEPARTMENT CONDITIONS * ** 14: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 nun). (IFC 906.7 and IFC 906.9) 17: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 20: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 21: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 22: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 23: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 24: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access doc: IBC -7/10 D11-362 Printed: 12 -01 -2011 corridor is more than 100 feet (30,480 mm) o0 listed viewing distance for the sign, whiche Pr is less, from the nearest visible exit sign. (IFC 1011.1) 25: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 26: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) 27: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot - candle (11 lux) and a minimum at any point of 0.1 foot - candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot- candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 28: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 29: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (1FC 901.4) 30: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 31: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 32: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 38: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 39: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 40: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 41: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -362 Printed: 12 -01 -2011 CITY OF TUKW Community Develop Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Site Address: 17 2-5-0 SOFT CEN -tcR PARKii( Suite Number: / 1 Floor: Tenant Name: �PRO)F`ERTYOWNR,,> x.,Y J TO�ect t ,., r, <. Name: WIG PROP 1E r h Fz..�s City: KL RFai4N� State:GJ 7p O3 7 �� Address: CI S'11 13LITN PL SE S City:ri 1E 11 R. V O t Stater 1 Zippgc Yq F aY 2 R LY f( ] J 7 11 i CONTACT PERSON person receiv>Iii i�. ?R' �Yl�r �"r �:t'r� i- >�L.v commumcaonci {hd4 .. J TO�ect Name: P RQ F JR-, -■ Address: City: KL RFai4N� State:GJ 7p O3 7 �� Address: y l/ l y 714 .PL S State: City:. R_ vij State: Phone: Zip: 9B.664 Phone: 7_S3 4.8-4. Ear 4=2,7 I . Contr Reg No.: Email: Email: Exp Date: Tukwila Business License No.: GEN..... .,NlW. . OR INF litik .T)CO: Company Name: I C P RQ F JR-, -■ Address: City: KL RFai4N� State:GJ 7p O3 7 �� Phon LL 8-2,-7 'al Fax: Email: City: State: State: Zip: Phone: Zip: Fax: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:Vlpplications\porms- Applications On Line \2011 ApplicationsWermit Application Revised - 8 -9 -1 l.docx Revised: August 2011 bh New Tenant: ❑ Yes (V.. No �kCI ''CTCIFRCU1tD►k�h ° i � "'a`�t���" Company Name: FR t N g _ e ti O Architect Name: Tom SP I D A • Address: . s ao9 Lk, 0ASN;NCa7-6N sKL.ifO City: KL RFai4N� State:GJ 7p O3 7 �� Phon LL 8-2,-7 'al Fax: Email: L'NO!NE R l�i'pECORD p j1 ��..K_r� i 11 'Y'Lh't. t'TSyi :. 3, y,,,, ..":' �°uz�U.33Rt'�.cdt °u4 C. u8��"-�r*.$ Company Name: Engineer Name: Address: State: Zip: City: State: Zip: Phone: Fax: Email: QND ISSUED �.katt s P` quired `for. projects $S,000sbr ^t r *x d, d'n {,+, 't'";i• A u Y Yir2�'tlwk,,�!'u 'x a3;'. Name: Address: City: State: Zip: Page 1 of 4 NERMIGTiINF � A� Wia6�`431.��6�bR; Valuation of Project (contractor's bid pr; $ COO Existin ding Valuation: $ Describe the scope of work (please provide detailed information): ov2 r= ; n1 N 1 S E. S To E)6 S Y; P(6 l 8-? s' r` At e Nrz Res✓STcRe=6t^r4 !`FiC 4)R6P e12i t! iN Will there be new rack storage? ❑ ....Yes ..No If yes, a separate permit and plan submittal will be required. xN..?kk, ••�i:.. ,•;,�, ..c.. " a!rp - .E.�.#,::TMes;c'`�•"�, •- t,e. `:*.��Cr 2zxg� Zia, d ,i` f- - %� L i .. 4Lt aY :yy h xi ,:,,� x, .�.1Fr; -i~P�'ci�i,•. �?3'.e rr • ,vt .+ a. 3 p 'F «{• �t <..i;"d k.� - ,(":y TS >�Y.. k Interior�Remodel� ;i�;r � - .:::,e :r'. <'�Addit"io i t •> ��� F T k ' -m i ��t�f R . ..� . ���Sticucture � :::�k; 'a,i.3. s3k ^'°^4� rte, ' sr. _ . N , .t ., 1.�. 'r+ �}. 3�z1 +� T . �G,A- -k fi lst '� x,� 1 ,w YpY ��,New, �1 h.� "ire :. 1_":a ,- Type Of : •• :. y�,�¢ 5.� y i - :3:.i•`+!- L*,%` 4^. .s ,Construction r m, :. a lie is .t Y 1 �:s � IBG,:k��-r,�T. :_,z.''" • -r;S_, ,� : .,, � , TyPe k 'i.E ^.,9. F2ise - :t;.2ti , Occu erg panty P, Pr � ,f '' ''1' Floor u l •2Foorll •*;t_ 3r °Floor`�C's, "IFloorsa�i2 {?ttyh[ru� >,Y z3�KSt_Y,.tc .... ....?nd,. ..✓, .lima +.14...n .r._tS� ccessory Struct,.u��re±i,� °. 1 y`,.' i4 �• r r 41 "'y� o f �- e 4 AttachedxGarage ��` � � , �� icAfe Detached;G if. agey;;T* Attached Carportx 1 , t :I. .I eticl ed Carport,t� ov e�ek''� Uncoir.'Ca ecl �� �, .• , i PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes -A, No If "yes'. attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:1Applications\Forms- Applications On Line1201 1 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 2 of 4 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin ° #1` for'fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate 0... Highline ❑ ...Valley View ❑...Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑... Geotechnical Report 0... Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage 0... Abandon Septic Tank 0... Curb Cut 0... Pavement Cut 0... Looped Fire Line ❑ .. Permanent Water Meter Size... ❑ .. Temporary Water Meter Size .. ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public WO # WO # WO # Private ❑ Private ❑ 0... Grease Interceptor ❑... Channelization 0... Trench Excavation 0... Utility Undergrounding ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- I1.docx Revised: August 2011 bh Page 3 of 4 Value of Construction - In all cases, a value construction amount should be entered by the app ant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review- Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT : • ED AG Signature: Print Name: 6 R &o E01t) i>Q %l'( Mailing Address: Li $ 11 13/4 H PL. 5 (i H,\Applications\Forms- Applications On Line12011 Applications\Permit Application Revised - 8 -9 -11. docx Revised: August 2011 bh Date: /f -y -.11 Day Telephone: ZS" lots4. Ip Z71 0E1_1 klit) City LJ ?Bao4 State Zip Page 4 of 4 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 7888920020 Permit Number: D11 -362 Address: 17250 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 11/07/2011 Applicant: VANILLA SHELL Issue Date: Receipt No.: R11 -02601 Initials: User ID: Payee: WER 1655 Payment Amount: $738.15 Payment Date: 12/01/2011 02:19 PM Balance: $0.00 MANMOHAH WIG (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04642G ACCOUNT ITEM LIST: Description 738.15 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 733.65 640.237.114 4.50 Total: $738.15 doc: Receipt -06 Printed: 12 -01 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.Qov RECEIPT Parcel No.: 7888920020 Permit Number: D11-362 Address: 17250 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/07/2011 Applicant: VANILLA SHELL Issue Date: Receipt No.: R11 -02427 Initials: User ID: WER 1655 Payment Amount: $476.87 Payment Date: 11/07/2011 10:58 AM Balance: $738.15 Payee: GREGORY EDWARDSON TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 02760G ACCOUNT ITEM LIST: Description 476.87 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 476.87 Total: $476.87 doc: Receiot -06 Printed: 11 -07 -2011 INSPECTION RECORD Retain a copy with permit ,dpi -362 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 � (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ' £4 A/% .5�Ae/ / Type of Inspection: .4 / Address; / 72 5-(,) 5,0/61,405.,4-.. / Date Called: Special Instructions: n 5'6796 -d/ Date Wanted:. /e.? - )c !/ .m.' P.m. Requester: Phone No: 0253 -69.4 -42 77 • Approved per applicable codes. E Corrections required prior to approval. COMMENTS: f)4' Ak, Date: /_2-- ?/F SPECTION FEE REQUIRED. rior to net inspection� must be d at 6300 Southcenter Blvd.. Site 100. ll to schedule reinspection. e. • INSPECTION NO. INSPECTION RECORD Retain a copy with permit 011-3(3 Z. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: V 1.11L-Lra GI.iE Li- Type of Inspection: 21SP PJcP6 (',ii-'J/ Address: So) , I iv i,r 6...■ i er4 Date Called: Special Instructions: • . / Date Wanted :. a.m. 1 2- 2 3 r( P.m. Requester: Phone No: ..)53 (SG -6277 ,Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Date: /2— Z,-// NSPECTION FEE REQ IRE . Prior to next inspection. fee must be aid at 6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. Qc1 -3(:,Z PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 do_ Permit Inspection Request Line (206) 431 -2451 Project: ,4 1/ r/ l l—L'`1 S 1-1 E L L Type of Inspection: l= 2 A r� � ,./ b Address: 1"7250 c►.i- rkic'fp.rrk Date Called: Pct Special Instructions: . Date Wanted:. Imo- ►3- 11 m: p• Requester: Phone No: X53- C,vC- C:Z•_---7 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (0 1.1-17 *441 ki £m a-i h ✓ 01/440 S 1 1.1• E ,4-DD 4-v,strodwa (etc I Date: 12 -1�' IN PECTION FEE REQUIRED. Prior to fiext inspection. fee must be id -t 6300 Southcenter Blv . Suite 100. Call to schedule reinspection. INSPECTION NUMBER ."Ps.,' .7,0. Jr -01' Ikr •. ... .p... `•'rn = .' ±• :44.1.-. ... . r INSPECTION RECORD Retain a copy with permit Dll -- 34g-- 11 P a7/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: 11 -P1),1 i 6- R ZS k Type of Inspection: �4 -- --;'f �. 'it) 4.1 Address: ) 7 g O Suite #: ii b 5.(._ fd l'' 'f Contact Person: Special Instructions: Occupancy Type: Phone No.: rk-Afjproved per applicable codes. Corrections required prior to approval. COMMENTS: -P4 0/L Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: yn a-- Date: /2 /a 9 /// Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: 1 State: Zip: Word /Inspection Record Form.Doc 6/11/10 :�F,, D. Form F.P. 113 • • Freiheit & Ho architects November 22, 2011 WIG PROPERTIES, LLC 4811 134TH PLACE SE BELLEVUE, WASHINGTON 98006 ATTN: CLAUDINE SIEDLER RE: Claudine: FILE COPY De, woe^I. PO A_ SUITE S116 TENANT IMPROVEMENTS SOUTHCENTER SQUARE TUKWILA, WASHINGTON In regards to the work being done at suite S116 at Southcenter Square, please note the following changes to the drawings: The demising walls are existing, so no fireblocking will be added. The new restroom walls can be constructed to 12' -0" a.f.f. These walls need to be braced using 3 5/8" studs attached to the top of the wall, and spaced at not more than 4' -0" apart. These braces should be attached to the roof structure or an adjacent wall. Please let us know if you need anything further. Sincerely, FREIHEIT & HO ARCHITECTS, INC., P.S. Thomas L. Spader, /CIA Associate Principal CC: EVISIO NIL_L tl1 3(ol REVIEWED FOR CODE COMPLIANCE APPROVED DEC 07 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 01 2011 PERMITCENTER TEL: 425 827 2100 FAX 425 828 6899 WEB: www.FHOARCH.COM ADDRESS: 5209 Lake Washington Blvd N.E. 1 Ste 200 1 Kirkland 1 WA ( 98033 RftRRfCf�fCF6fCPefnFCf6F�'( �` i�' in` fCRf6' fCF�` f$ F" �i6' fCFCiCF6PfAf�' fCf�' f6fefCi$ F�' fEPi0fAF6f6f6f$ f6' f6f� 'PFi'F6f6Rf$FifCiSfCf$f6'f6i$ fCfC ftftRItItI RRRFf; RRRRRRRRRRRRRRRRRRFBRRRRRRRRRRRRftIVItINftRRRRRRRRftPtRRRRRRRSfCPR ftRRRRRRRRRRRRRitRRRRRRRRRRRRRRRRRRRIIMMItIttftftattltitittRRRRRRRRRRRftftRRf6RRRRR FREIHEIT E HO ARCHITECTS, IN oPE PLAN REVIEW /R • ING SLIP ACTIVITY NUMBER: D11 -362 DATE: 12 -01 -11 PROJECT NAME: VANILLA SHELL SITE ADDRESS: 17250 SOUTHCENTER PY Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued EPART TS: I ?-- CI u ding Div ion N Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -06 -11 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 01-03-12 Not Approved (attach comments) Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 on I PLAN REVIEW /ROUTING SLIP i ACTIVITY NUMBER: D11 -362 DATE: 11 -07 -11 PROJECT NAME: VANILLA SHELL SITE ADDRESS: 17250 SOUTHCENTER PY - SUITE 116 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DE RTTM,l�NTIS: LI ding uivisio% / + Public Works Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-08-11 Complete Comments: Incomplete n Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 3 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 12 -06 -11 Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: Vatei I 1) 51, I ' SITE ADDRESS: \V-n NOJ'M.evt-L— �y PERMIT NO: U 1 1 ORIGINAL ISSUE DATE: .. REVISION LOG REVISION NO. DATE RECEIVED STAFF INIT ALS ISSUED DATE STAFF INITIALS Summary of Revision: ('PSG. rdnin . cdt/a lk elvAb e S Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 Plan ChecWPermit Number: ) 1 k -60)- ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: 14 1,1`i Project Address: / 7Z5 S00J714 i'J2,VTt2 tom/ 1t cw xi Contact Person: , zz--A,vc4 -$1 0g ( Phone Number: zS3 �7� Summary of Revision: N • ur I UttWILA ,uti, 011011 PERMITCENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date o revisio Received at the City of Tukwila Permit Center by: 11.___Entered in Permits Plus on H: Applic iio u Forms- Applicthons On Line\2010 Applicstions\7 -2010 - Revision Submi0sl.doc : 8-13-2004 Revised: 7 -2010 11/21/2011 22:14 4258658648 WIG PROPERTIES LLC 11- 21 -'11 11:22 MOM pu cworks /Jud 20643Libb5 CITY ±' TVICWILA Department OfCommonly Development 6300 Bout :emir Boulevard, TLbuiln, WA 98,88 Alephone: (m6)431-9670 PAX (206) 432 -9665 • PAGE 01/01 P002/003 F -423 Portnit Center /Budding Division 206432-3670 Public Works Department 206 4S8 -o179 Planning Division 206 431 -3670 AFFIDAVIT IN LIETJ OF CQNyTRACrOR REGISTRATION STATE OF WASHINGTON) ) tae. COUNTY OF RING ) Gpleasc prim name] 1 & states as follows: P R3�r T Non 11 9) (02- 1. 1 have made applicat iou for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington: The eameptions to this requirement are stated tinder Section 18.27.096 of the Revised Code of Waahiogton, a.eopy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27,090. 9. I understand tbat.prio, to issuance of a permit for work which is to be done City of Tukwila must vrlrify either that the contractor is by any contractor, the one of the exemptions y the State of Washington, or that pt4oris Mated under RCW x8.27.090 applies. 4. in order to provide veiitcation to the City of Tukwila of my compliance with this requirement, I hereby attest that after treadittgg the exemptions from the registration requirement of RCW 18417.090, I consider the work authorized under this permit to be exempt under number �� fbe performed by a mgistered contractor. 1L, and will therefore 5. I understand that thelioensinsg rovmlon of RCW 19.28.161 through 19.28.271 sbaf not a pe r ens vn the remises 1 • ns on their own property or to regubidy employed pies of a aenw btntd g four rent, Bale or ]�e ,The pmpoaed elm work le not for the coast ruetfotn I understand that I maybe waiving certein rights that I might otherwise have under state law in any decision to engage an unregistered con.trentor to perfoun construction work. RECEIVED 11- 22 -'11 11:14 FROM- Signed and sworn to before me thin L day of A__))4.. i & be+2.. 201_4 NOT , ' PUBLIC in and for the State of Washington Residing at County Name as commissioned: X11]_ -a' c5W4ER. My commission expires: 71)0, 4258658648 TO- publicworks /dcd P001/001 LANDLORD WORK SUITE S116 17250 SOUTHCENTER PARKWAY SUITE S116 SOUTHCENTER SQUARE SOUTHCENTER PKWY. & MINKLER BLVD. TUKWILA, WASHINGTON 98188 FELE 'OP! Penn No. Plan review approval is subject to errors and =Wont Approval of construction- doeurants clops act the violation of any adopted codo or ordinanca Re-.;,c,!pt of approved Field Copy °$ wietto 12-/ City Of witikwila RWLDING DIVLSION YAArehibmithiral Prrtiortir111114.1YA11-4RAIR IRRFAIT PHARF nwrm9 Rhatatc‘A11-ARA RI nn R-1 1R Ani rlwn Alm n9 9(111 _in-sn.m.rtrnmar C.1 Zi:WPW mpaW /0:1-•: „.•ft 7812 .0MAS, • , STATE CF .'• REV DESCRIPTION COVER SHEET DATE A0.1 PROJECT NUMBER: A11-484 11/02111 FREIHEIT & HO ARCHITECTS, INC., P.S. APPLICABLE CODES VICINITY MAP ITLE INDEX REVIEWED FOR BUILDING CODE - 200q INTERNATIONAL BUILDING CODE PLUMBING CODE - 200qr UNIFORM PLUMBING CODE ELECTRICAL CODE - 2008 NATIONAL ELECTRIC CODE MECHANICAL COPE - 200q1 INTERNATIONAL MECHANICAL CODE FIRE PROTECTION - 200°1 INTERNATIONAL FIRE CODE ENERGY CODE - WAG 51-11 WASHINGTON STATE ENERGY CODE HANDICAP CODE - 20001 IBC AND ICC ANSI A111.1-2005 f • ANCE ARCHITECTURAL APPROVED ... .. - -- . .... . --- ::.:f::•x•:- • ltIvi , ''' .. -- A-0.I COVER SHEET , NOV 1 7 2011 A-2D REFERENCE SITE PLAN A-30 FLOOR PLAN / DETAILS / SCHEDULES A-6D RESTROOM PLANS / DETAILS CitY of ila A--7.0 REFLECTED CEILING PLAN / DETAILS BUILDING I ISION _ \\L'I LVID li Y PROJECT DATA 5 I 110T ST t 5 I E T LOCATION SUITE 5116, 1250 SOUTHCENTER PAR KWAY, TUKWILA, INA ZONING: TUKWILA URBAN CENTER (TUC) OCCUPANCY: M, (MERCANTILE) NUMBER OF STORIES: I CONSTRUCTION TYPE: TYPE v-5, FULL'( SPRINKLERED TENANT SQUARE FOOTAGE: SUITE S148 1,8416 S.F. OCCUPANT LOAD: 1,8°16 S.F. / 50 = 64 OCCUPANTS BUILDING SQUARE FOOTAGE: BUILDING 'N' 46,611 S.F. ..,„, ACCESSORS PARCEL (NUMBERS 262304°1080 262504°1081 262504°1111 DESCRIPTION OF INORK: PROVIDE NEW RESTROOM, CEILING AND LIGHTING 4 11 a 111 E N<LE1 DI -,--- li i 5 PROPOS ir -4' No cohle,flogreksv,srithRhaoE11:17spiOrmioNarSdaepptorot‘h„:71 cope r) p e Tukwila Building Division NOT:: Ezvis:ons will require a new plan subrntcl &roll rnzy rude addonal plan re'/C' fzes .... j ili it--- SITE V. etz 5 Lu iii > > 0 • 0 ST .-x- i) Di , Is-- x z 0 < . < I --,_ is) 5 1 TH S 1 symBoLs ABBR E V 1 AT IONS G E N E RAL No S ALI SUf3-00 NTRACTORS MUST BE WORKING FROM A 1911 SET OF DOCUMENTS. ALL SUB-CONTRACTORS TO VERIFY ALL DIMENSIONS FOR THEIR SCOPE OF WORK. IN EVENTS OF CONFLICTS OR CHANGES 13ETWE5■1 DETAILS OR BETWEEN PLANS AND SPECIFICATIONS, NOTIFY THE ARCHITECT IMMEDIATELY. NO MATERIALS OR PRODUCTS CONTAINING ASBESTOS ARE TO BE UTILIZED IN THIS PROJECT. NO PRODUCTS ARE TO E3E UTILIZED IN THIS WORK THAT WILL REQUIRE SPECIAL INSPECTIONS OF HAZARDOUS MATERIALS SHOULD THEY BE REMOVED. ALL CONSTRUCTION SHALL CONFORM TO THE 200q EDITION OF THE INTERNATIONAL BUILDING CODE. ALL CONSTRUCTION SHALL BE DONE IN ACCORDANCE WITH THESE PLANS 4 PROJECT SPECIFICATIONS. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS. IN THE EVENT OF CONFLICTS OR CHANGES BETWEEN DETAILS OR BETWEEN THE PLANS 4 SPECIFICATIONS, NOTIFY THE ARCHITECT IMMEDIATELY. FINISH FLOOR REF. DATUM EQUALS (1001-0"). REFER TO TOPOGRAPHIC SURVEY FOR ACTUAL SITE ELEVATION. ALL DIMENSIONS ARE TO FACE OF CONCRETE, MASONRY, FACE OF FRAMING OR COLUMN CENTER LINES U.N.O. ALL MOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED WOOD OF ANY SPECIES OR FOUNDATION GRADE CEDAR OR REDWOOD, ALL MARKED BY AN APPROVED TESTING, AGENCY. ALL WOOD FORMS USED FOR CONCRETE, IN THE GROUND OR BETWEEN FOUNDATION SILLS 4 THE GROUND SHALL BE REMOVED. PROVIDE HORIZONTAL F1REBLOCKING IN ALL FRAME WALLS AT 10I-0" O.G. 4 WHERE FRAME WALLS PENETRATE CEILING. FIREBLOCK IN ACCORDANCE WITH 1.5.0. SECTION 1112. DRAFTSTOPPING IN FLOORS 15 NOT REQUIRED IN BUILDING'S EQUIPPEI7 'THROUGHOUT WITH SPRINKLER SYSTEMS IN ACCORDANCE WITH 1.13.C. SECTION q033.1.I. (IB.0 SECTION 717.33) DRAFTSTOPPING IN ATTICS 15 NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC. SPRINKLER SYSTEM IN ACCORDANCE WITH I.B.G. SECTION q033.1.1. (IB.C. SECTION 111.43) PROVIDE A FLOOR OR LANDING NOT GREATER THAN 1' BELOW THRESHOLD AT ALL DOORWAYS. PROVIDE BLP G,. ADDRESS PER OWNERS WILDING, STANDARDS. EGRESS DOORS SHALL I3E READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 1BL. SECTION 1008•1•q.1 HARDWARE. 1700R HANDLE-5, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES ON DOORS REQUIRED TO BE ACCESSIBLE BY CHAPTER 11 SHALL NOT REQUIRE RIGHT GRASPING, TIGHT PINCHING OR TWISTING OF 'ME WRIST TO OPERATE. LOCKS AND LATCHES PER !B .C. SECTION 1008.1.413. LOCKS AND LATCHES SHALL BE PERMITTED TO PREVENT OPERATION OF DOORS WHERE ANY OF THE FOLLOWING EXISTS: 2. IN BUILDINGS 114 OCCUPANCY GROUPS M, THE MAIN EXTERIOR DOOR OR DOORS ARE PERMITTED TO BE EQUIPPED WITH KEY-OPERATED LOCKING DEVICES FROM THE EGRESS SIDE PROVIDED: 2.1 THE LOCKING P'/IC 15 READILY DISTINGUISHABLE AS LOCKED, 22 A READILY VISIBLE DURABLE SIGN 15 POSTED ON THE EGRESS SIDE OR ADJACENT TO THE DOOR STATING: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. THE SIGN SHALL BE IN LETTERS I INCH HIGH ON A CONTRASTING, BACKGROUND. ALL ROOMS OR AREAS HAVING AN OCCUPANT LOAD OF 50 (1,500 SF OF RETAIL SPACE) OR MORE SHALL HAVE AT LEAST 2 EXITS TO THE EXTERIOR OR TO AN EXIT CORRIDOR ( ONE-HOUR CONSTRUCTION). ( IB.C. SECTION 1015.1 ) EXITS SHALL HAVE A MIN. SEPARATION OF ONE HALF TI-E MAX. OVERALL DIAGONAL OF THE BUILDING OR AREA SERVED, MEASURED IN A STRAIGHT LINE BETWEEN EXITS. (I.B.C. SECTION 10152.1) EXCEPTION 2 - WHERE A BUILDING 15 EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH 1B•. SECTION 61033.1J OR q03.3.12, THE SEPARATION DISTANCE OF THE EXIT DOORS OR EXIT ACCESS DOORWAYS SHALL NOT I3E LE55 THAN ONE-THIRD OF THE LENGTH OF TI-E MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED. EXPOSED INSULATION MATERIALS INCLUDING FACINGS AND VAPOR BARRIERS, SHALL HAVE A FLAME SPREAD RATING NOT TO EXCEED 25, AND A SMOKE DENSITY NOT TO EXCEED 450, OR SHALL BE IN SUBSTANTIAL CONTACT WITH THE NALL OR CELINE/ SURFACE FINISH. (IB.C. SECTION aos) ELECTRIC RESISTANCE HEAT 15 NOT ALLOW UNLESS THE INASHINSTON STATE NON-RESIDENTIAL ENERGY CODE COMPLIANCE FORM 15 REVISED. LIMIT AIR LEAKM PER 115.EL SECT 1314 E .. . . WHEN THE FLOOR AREA OF 'GROUP B OR GROUP M' OCCUPANCIES EXCEED 3000 S.F•, TINO BARRIER FREE RESTROOMS VIILL BE REQUIRED. 2102.1.1 WASHINGTON STATE AMENDMENTS WHEN THE OCCUPANT LOAD EXCEEDS 50 THE DOORS MUST SWING, IN THE DIRECTION OF EXIT TRAVEL. IBC SECTION 1006.12 DEAD END CORRIDOR IBL. SECTION 1018.4 EXCEPTION 2: 114 OCCUPANCIES IN GROUPS B AND F WHERE Ti-IE BUILDING 15 MIFFED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM 114 ACCORDANCE WITH !B•C. SECTION 61033•1•1, THE LENGTH OF DEAD END CORRIDOR SHALL NOT EXCEED 50 FEET (15240 MM) PROVIDE SUITE NUMBER ON MAIN ENTRY DOOR PER FIRE DEPARTMENT REQUIREMENTS. BUILDING SECTION or,:-/-7":$14k, \ NORTH ARROW $ AND EQ. EQUAL O.G. ON CENTER. L ANGLE EQUIP. EQUIPMENT 0/ OVER AT EXPO. EXPOSED OPP. OPF'OSITE CENTERLINE EXIST. EXISTING 1:13' E7IAMETER OR EXT. EXTERIOR PL. PLATE ROUND F.O.1.C. FURNISHED 5Y OWNER PLYWD. PLYWOOD _L PERPENDICULAR INSTALLED BY CONT'R. PP. POWER POLE # POUND OR NUMBER F.D. FLOOR DRAIN PLAM PLASTIC LAMINATE A.B. ANCHOR BOLT F.E. FIRE EXTING,- ACOU5. ACOUSTICAL U15HER R. RADIUS OR RISER A.F.F. ABOVE FINISH FLR. F.H. FIRE HYDRANT R.D. ROOF DRAIN A6GR. AGGREGATE FIN. FINISH REC. RECOMMENDED ALUM. ALUMINUM FLASH. FLASHING, REF. REFERENCE ANOD. ANODIZED FLR. FLOOR REINF. REINFORCED APPROX. APPROXIMATE FLUOR. FLUORC:-.4ENT REQ'D. REQUIRED ARCH. ARCHITECTURAL FOUND. FOUNDATION RM. ROOM ASPH. ASPHALT FIRKG. FRAMING FT. FOOT OR FEET 5. SOUTH BD. BOARD FTG. FOOTING 5.C. SOLID CORE BLD6. BUILDING FURR. FURRING SCHED• SCHEDULE BLK. BLOCK 6A. GAUGE SHT. SHEET MK'S,. BLOCKING GALV. GALVANIZED !HT'. SHEATHING BM. BEAM G.C. (GENERAL CONTRACTOR SIM. SIMILAR BOT. BOTTOM L. GLASS SPEC. SPECIFICATIONS B.U.R. BUILT UP ROOF 6,ND. GROUND SQ. SQUARE 6,R. GRADE 5M:7. STANDARD CAB. CABINET 6P. GROUP STL. STEEL C.B. CATCH BASIN G.W.B. GYPSUM WALL STOR. STORAGE GEM. CEMENT BOARD STRIJC. STRUCTURAL H. CHANNEL 6YP. (GYPSUM SUSP. SUSPENDED C..1. CONTROL JOINT 5.4 V. STAIN AND VARNISH CLAP. CEILING HDVIR. HARDWARE SVC. SERVICE CUR. CLEAR HDCP. HANDICAP SYM. SYMMETRICAL CD. CLEAN OUT HDVID. HARDWOOD 5/1A1 SIDEWALK COL COLUMN H.B. HOSE BIBS CONC. CONCRETE H.G. HOLLOW CORE T. TREAD CONN. CONNECTION H.M. HOLLOW METAL T•C• TOP OF CURB CONSTR. CONSTRUCTION HORIZ. HORIZONTAL TEL. TELEPHONE CONT. CONTINUOUS HR. HOUR T.4 G. TONGUE AND (GROOVE C.T. CERAMIC TILE HT. HEIGHT THK. THICK CENTER T.O.P. TOP OF PLATE CTSK. COUNTER SUNK INST. INSTALLATION T.P. TOP OF PAVEMENT INSUL. INSULATION T.W. TOP OF WALL DBL. DOUBLE INT. INTERIOR TYF'. TYPICAL DEPT. DEPARTMENT PET. DETAIL LAM. LAMINATED U.B.C. UNIFORM BUILDING DIA. DIAMETER LB. POUND CODE DIM. DIMENSION LOC. LOCATION UNF. UNFINISHED N. DOWN U.O.N. UNLESS OTHERWISE DR. DOOR MATL. MATERIAL NOTED D.S. DOWNSPOUT MAX MAXIMUM DING. DRAWING, MFR. MANUFACTURER VERT. VERTICAL M•H. MANHOLE E. EAST MECH. MECHANICAL W. INEST EA. EACH MIN. MINIMUM kV WITH E.I.F.S. EXTERIOR INSULATION MI5C. MISCELLANEOUS YID. V•1000 FINISH SYSTEM MTD. MOUNTED MK WINDOW •• EXPANSION JOINT MTL. METAL W/0 WITHOUT EL. ELEVATION W.R. WATERPROOF ELEC. ELECTRICAL N. NORTH W•P. WATER RESISTANT ELEV. ELEVATOR N.I.G. NOT IN CONTRACT MOT. WAINSCOT ENCL. ENCLOSURE NO. NUMBER INT• WEIGHT EP. ELECTRICAL PANEL N.T.S. NOT TO SCALE L ION GAL D SCRIP A-3 A SECTION IDENTIFICATION . <---- LOCATED ON SHEET-. WALL sEcTION ---- [\ ) DESCRIPTION: PARCEL A: THAT PROTION OF THE NORTHWEST WEST QUARTER OF SECTION 26, TOWNSHIP BEGINNING AT THE NORTHEAST CORNER TI-ENCE NORTH 66°05'42' NEST ALONG, FEET TO THE PEST LINE OF THE EAST 'THENCE SOUTH 01°4112q" WEST ALONG I3EGINNING; THENCE CONTINUING ALONG SAID NEST GARTER OF THE SOUTHF-AST QUARTER; THENCE NORTH 81°55'02" WEST ALONG, QUARTER OF THE SOUTHEAST QUARTER; THENCE NORTH 01°121251 EAST ALONG TI-ENGE SOUTH 66°00'36" EAST 673.30 EXCEPT THAT PORTION CONVEYED q4082°10323 FOR MINKLER BOULEVARD; SITUATE IN THE CITY OF TUKWILA, COUNTY • PARCEL B: THAT PORTION OF THE NORTHEAST RANGE 4 EAST, W• M., DE-SCRIBED A5 BEGINNING AT THE NORTHEAST CORNER THENCE NORTH 66°05142" WEST ALON6 FEET TO THE EAST LINE OF SAID NORTHEAST THENCE SOUTH 01°121251 WEST ALONG THENCE CONTINJING SOUTH 01°1225" SOUTHWEST QUARTER; NCE NORTH 8755'53' WEST ALONG THENCE NORTH 01°56'21" EAST 344.°15 THENCE NORTH 87°55'53" VEST 48 FEET; THENCE SOUTH 02°041071 WEST 10 THENCE NORTH 61°55'53' WEST 3/1.45 THENCE SOUTHWESTERLY ALONG SAII7 34.61 FEET; THENCE NORTH 01°0835" EAST TO A THENCE STOUTH 66°00136" EAST TO EXCEPT THAT PORTION CONVEYED TO q 4082°1032 3 FOR MINKLER B OULEVARD; SITUATE 114 'ME CITY OF TUKWILA, COUNTY PARCEL C• THAT PORTION OF THE NORTHEAST RANGE 4 EAST, W.M• , DESCRIBED AS BEGINNING AT THE NORTHEAST CORNER THENCE NORTH 88°05421 VEST ALONG FEET TO THE EAST LINE OF SAID NORTHEAST THENCE SOUTH 01°121251 WEST ALONG TO THE SOUTH LINE OF SAID NORTHEAST THENCE NORTH 81°5553" WEST ALONG THENCE CONT1JNUINS NORTH a7°5553" PARKWAY; THENCE NORTH 01°08'35" EAST 3I45q RIGHT WITH A RADIUS OF 25 FEE; THENCE NORTHEASTERLY ALONG, SAID 3.67 FEET; THENCE SOUTH 87°55'53" EAST 311•43 'MEN GE NORTH 02°04101° EAST 10 THENCE SOUTH 81°5553" EAST 48 FEET; THENCE SOUTH 01°58,1271 PEST 3441•95 QUARTER OF THE SOUTH EA'S- T-QUARTER AND OF THE NORTHEAST QUARTER OF 'THE SOUTH 23 NORTH, RANGE 4 EAST, KM., DESCRIBED AS FOLLOWS; OF THE SOUTHEAST QUARTER OF SAID SECTION 26; THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF lqq8b8 654.34 FEET OF SAID NORTHWEST QUARTER OF THE SOUTHEAST QUARTER; SAID WEST LINE A DISTANCE OF 65825 FEET TO THIS TRUE POINT OF LINE, A DISTANCE OF 662.05 FEET TO THE SOUTH LINE OF SAID NORTHWEST SAID SOUTH LINE, 66656 FEET TO TI4E VEST LINE OF THE NORTHWEST SAID WEST LINE, 661.03 FEET; FEET TO THE POINT OF BEGINNING; TO THE CITY OT TUKWILA BY DEED RECORDED UNDER RECORDING NO. OF KING, 5TATE OF WASHINGTON. QUARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, FOLLOWS: , I OF TEH SOUTHEAST QUARTER OF SAID SECTION 26; THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF 2616.66 QUARTER OF THE SOUTHWEST QUARTER; SAID EAST LINE 6572q FEET TO THE TRUE POINT OF 13E&INNING,; NEST 661.03 FEET TO THE SOUTH LINE OF SAID NORTHEAST QUARTER OF THE 1 , SAID SOUTH LINE, 18528 FEET; FEET; FEET; FEET TO A TANGENT CURVE TO THE LEFT, WITH A RADIUS OF 25 FEET; CURVE THROUGH A CENTRAL ANGLE OF q0°5551", AN ARC DISTANCE OF Cf---5■1,-)/t---:- -- POINT NORTH 880001360 VEST FROM THE TORE POINT OF E356,INNIN6; 1/4.:Cf-i•Art, 11 iz Rzi-IMIT THE TRUE POINT OF 13EGINNIEn fiZQUIRED FOR 0 Mechanical 'THE CITY OF TUKNIILA BY DEED RF_CORDF_D UNDER RECORD1N& NO. Electrical Plumbing OF KING, STATE OF WASHINGTON. Gas Piping City of Tukwila LY DIVISION GARTER OF THE SOUTHWEST QUARTER OF SECTION 26, TOWNSHIP 23 NORTH, FOLLOWS: OF THE SOUTHEAST QUARTER OF SAID SECTION 26; THE NORTH LINE OF SAID SOUTHEAST QUARTER, A DISTANCE OF 2618•68 QUARTER OF THE SOUTHWEST QUARTER; RECEIVED SAID EAST LINE 1318.32 FEET QUARTER OF THE SOUTHWEST QUARTER; NOV 07 2011 SAID SOUTH LINE, 18528 FEET TO THE TRUE POINT OF BEGINNING WEST 43.2 FEET TO THE EAST RIGHT-OF-MY LINE OF SOUTHCENTER PERMIT CENTEF FEET ALONG SAID EAST RIGHT-OF WAY LINE TO A TANGENT CURVE TO THE ,.. CURVE THROUGH A CENTRAL ANGLE OF 410°5551", AN ARC DISTANCE OF FEET; FEET; FEET TO THE TRUE POINT OF E3EGIN4ING; SECTION IDENTIFICATION ELEVATION MARKER A-3 < LOCATED ON SHEET.. DETAIL *--- DETAIL IDENTIFICATION FINISH GRADE ELEVATION 1 .0 . TOP OF CURB T .16.0 TOP OF PAVEMENT T .15.5 1 A-5 A-1 <--- LOCATED ON SHEET INTERIOR ELEVATION <----- ELEVATION IDENTIFICATION OFFICE .-- D LOCATE ON SHEET ROOM SYMBOL CENTER LINE ROOM NAME 101 ROOM NUMBER PROPERTY LINE ROOM MATERIAL CODES IA2 1St No FLOOR/I3ASE 2nd No WALLS/WAINSCOT j 5rd No CEILING, NEW CONTOUR q' - 0" CEILING HEIGHT 1 GRID MARKERS 1 .. A LETTERS IN ONE DIRECTION EXISTING CONTOUR NUMBERS IN THE OTHER .......----15 DOOR SYMBOL REVISION CLOUD NUMBER ..--DOOR A MRK A IDENTIFYING NUMBER A ----DOOR < WALL SYMBOL 1*1 l< WALL IDENTIFICATION 1^11N1701,44 SYMBOL A,ININDOIN IDENTIFICATION LINES REPRESENT EXISTING TO REMAIN MATCH LINE BLACK LINES REPRESENT CONSUL AN S NEW CONSTRUCTION OWNER: ARCHITECT: W16, PROPERTIES L.L.C. 5•5 • I-134TH PLACE SE FREIHEIT 4 HO ARCHITECTS, INC•, P•S. 5201 LAKE WASHINGTON BLVD NE. SUITE 200 BELLEVUE, WA 418006 KIRKLAND, WASHINGTON '48055 PH: (425) 644-6126 FAX: (425) 865-8648 E -MAIL: W PH (425) 821-2100 FAX: (425) 828-68cc CONTACT: ANJALI WIG CONTACT: TOM 5PADER 11) SHADED PORTION 15 THE SIDE CONSIDERED - - DASHED LINES INDICATE EXISTING -- - TO BE REMOVED YAArehibmithiral Prrtiortir111114.1YA11-4RAIR IRRFAIT PHARF nwrm9 Rhatatc‘A11-ARA RI nn R-1 1R Ani rlwn Alm n9 9(111 _in-sn.m.rtrnmar C.1 Zi:WPW mpaW /0:1-•: „.•ft 7812 .0MAS, • , STATE CF .'• REV DESCRIPTION COVER SHEET DATE A0.1 PROJECT NUMBER: A11-484 11/02111 FREIHEIT & HO ARCHITECTS, INC., P.S. CL INTERSE ?TION STA 50+001 NORTH ROA STA 45 +95;38 SOUTHCE +50 co N WIG BOULEVARD WIG BOULEVARD tnn inn:. ..- .. -... S4. NORTH RO STA TA 86 +57.90 63 +392 EAST ROAD AD 0 U 0 m '/// i i i i i i i i /117 ►r 0 U co O O R BOULEVARD E\JA.R.i AREA OF WORK REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2011 City of Tukwila BUILDING DIVISION SITE PLAN @ SUITE S116 NI RECEIVED NOV 0 7 2011 PERMIT CENTEF OM TEL 425 827 2100 1 WA 1 98033 5209 Lake Washington Blvd NE Gs 0 w 7812 1— 0 co ox 0 z 4 1 REGIS T ARCHITECT I REV DESCRIPTION C SPIDER .\S ING i ON SITE PLAN DATE A2.0 PROJECT NUMBER: A11.484 11/02/11 0 FREIHEIT & HO ARCHITECTS, INC., P.S. 1 DOOR SCHEDULE DOOR NO. MARK MARK A (EXISTING) SIZE/THK 1- 0 r cc x J N I a. CS DETAIL ot - BSCHI DETAILS FF = FACTORY FINISH 54V = STAIN *VARNISH 5.6.= 5EMI- GLOSS ANOD= FACTORY ANODIZED ALUMINUM REMARKS 3' -0"x7' -0" A ALUM TEMP ANOD EXIST EXISTING DOOR, SEE REMARK *1 BELOW B (EXISTING) 3' -0"0-0" B H.M. PAINT H.M. PAINT EXIST EXISTING, DOOR 3' -0"0 -0" SA PAINT H.M. PAINT G 2/A3.O EE REMARK *2 BELOW DOOR TYPES NARROW STYLE INSUL. SAFETY 6LAAS AO STOREFRONT DOOR ® EXTERIOR HOLLOW METAL DOOR O INTERIOR SOLID WOOD DOOR REMARKS: I. PROVIDE DECAL 51611 WITH I' BLACK LETTERS READING: THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS. LOCATE ON INSIDE OF TRANSOM. . PROVIDE AND INSTALL 6' SQUARE INTERNATIONAL SYMBOL OF ACCESS 5I6N ON WALL ADJACENT TO DOOR STRIKE. DOOR HARDWARE DOOR HARDWARE: A. I SETS TOP, MIDDLE, BOTTOM PIVOT HIN6E5 I MORTISE LOCK W/ THUMB TURN 3 -POINT I PUSH BAR I" 01UBE (1 a 51N6LE DOOR ) I SURFACE MTD. CLOSER LGN * 4010N/DEL SERIES OR EQUAL I 5E1' WEATHERSTRIPPING 4 SWEEP I THRESHOLD B. REAR SINGLE DOOR I -EACH EXIT ALARM: EXIT PANIC DEVICE WITH ALARM (VON DUPRIN GUARD X SERIES 2610) WITH ONE (1) ELECTRIC POWER TRANSFER (EPT) DEVICE (VON DUPRIN IEPT -ID) I -1/2 PR. BUTT HINGES: NAVY DUTY BUTTS HA6AR BB I27q 4.5X4.5, U26D I -EACH CLOSER: LGN SMOOTHES 4040, ALUMINUM. I -EACH THRESHOLD: HAGAR 5205A V3FT. I-EACH VIEWER: TACO TA33I0PG (MOUNT AT 5'-O" AFF) G. 1 I/2 PAIR BUTT HINGES I LEVER LOGKSET I CLOSER I DOOR STOP MALL MOUNTED IF APPLICABLE) BD.. � METAL YPRE'S l�', f'C,�f.:�„'i'. .s"Y.:� "`•.. "r:'::` ^� \ "� '':i /�`O ,':fk -f FRONIDE &IP TRACK • TOP OP MALL - PU1 fsAP9 Y'V 90104) 443U.ATION NEM METH. MO WALL PER FLOOR PLAN STOP GYP. 6" ABOVE CCUN& NB°1 GYP. BD. OWNS RESTROOM EOSINS CONCRETE FLOOR SLAB WALL SECTION SCALE: I/2 " =1' -0" DOOR JAMB DETAIL SCALE: 5 " =1'-O" ROOM FINISH SCHEDULE F W C FLOOR/BASE WALL/WSCT CEILING SEALED CONCRETE A TAPED, SMOOTH 4 READY FOR PAINT LAY -IN ACOUSTICAL CEILING 6:IO' -0' AFF 2 SHEET VINYL 6' VINYL BASE TAPED, TEXTURED d PAINTED W/ SEMI - &LOSS PAINT 48' 141614 PLASTIC LAMINATE WAINSCOT 2 TAPED, SMOOTH 4 READY FOR PAINT WALL TYPES SEE FINISH SCHEDULE FOR ALL FINIS1 E5_ 20 (MUSE 3 5/8" MTL. 5 0 16' D.G. 3' SOUND BATT INSUL. 5/8" TYPE 'X' 6JNB. ON BOTH SIDES EXTEND TO ROOF FRAMING r RE MEWS%' FOR G3DE COMPLIANCE APPROVED NOV 17 2011 City of Tukwila BUILDING DIVISION SUITE 116 (AREA: 1,896 S.F.) 116 A RR 2 B EXIT CORRIDOR 'S' BUILDING FLOOR PLAN @ SUITE 116 SCALE. I/4"= I -0 O �� 1 1 0 1 2 4 8 FT. 1) 11-3(ia� RECEIVE' NOV 072E1 PERMIT CENTEF 98033 wwweFHOARCHLCOM TL 425 827 2100 5209 Lake Washington Blvd NE 1 Ste 200 REV DESCRIPTION A001 'THOMAS O SPADER I STATE OF VAST-1INGTON ISTE REG -, \L 7 FLOOR PLAN / DETAILS / SCHEDULES DATE A3.0 PROJECT NUMBER: A11-484 11/02/11 ® FREIHEIT & HO ARCHITECTS, INC., P.S. 6J1B., PAINTED O tt 4'-6" 3'-6° 5' -0" CZ / 6' VINYL BASE 6J1B., PAINTED 4' -2' • 3' -0" 2' -0" I' -0" 2'-O' INSULATE HOT WATER 4 DRAIN PIPE 6 -1/2" MAX. DEPTH INSULATE HOT WATER 4 DRAIN PIPE 6" VINYL,BASE 6J113., PAINTED 2'-0 I /2' d3 1 W Aj %J T 6' VINYL BASE GOAT HOOK \N'ir 6JNB., PAINTED 6' VINYL BASE REST1200M KEYNOTES: ® WATER CLOSET AMERICAN STANDARD CADET ADA ELONGATED TOILET, 1.6 6PF (NWITE) © LAVATORY AMERICAN STANDARD LUCERNE WALL MOUNT SINK, 20" X 18' (WHITE) WITH DELTA 523 -11FHDF (CHROME) © PLASTIC LAMINATE WAINSCOT © INSTANT WATER HEATER, 208V ALL TOILET ROOM ACCESSORIES SHALL BE MANUFACTURED BY BOBRIGK OR APPROVED EQUAL unless otherwise noted. 0 TOILET PAPER HOLDER, 115-2150 SURFACE MOUNTED © PAPER TOWEL DISPENSER 118 -262, SURFACE MOUNTED 6 MIRROR, 418 -165, 24'x56 ", SURFACE MOUNTED ® SOAP DISPENSER, 418 -2111, SURFACE MOUNTED Q GRAB BARS, IB -6806 SERIES, IS', S6 ", 42" MOUNTED ON WALL ® WASTE RECEPTACLE, #SOBRIGK 13 -3644, REGCZf.ED (MOUNT PER MANUFAGTURER5 SPECS) Q SANITARY SEAT COVER DISPENSER, #B -2II, SURFACE MOUNTED RESTROOM ELEVATIONS SCALE: V2" = l'-O" TAMPONS DE E 0 45' CLEAR MIN. PATH OF TRAVEL FROM FACE OF ACCESSORY • 4" MAX PROTRUSION FOR ACCESSORIES HIGHER THAN 21" ACCESSORY u 11 O 0 0 4 in TAMPON DID URINAL PAPER TOWEL DISPENSER/ WASTE CONTAINER 51' MIN. 41' MAX. 12' MAX. 36" MAX. S.M. SOAP DISPENSER SURFACE MOUNTED PAPER TOWEL DISPENSER 54' MIN. � 4 PAN Q' MAX. FROM SEAT TO 6RA13 BAR SURFACE MOUNTED HAND DRYER MIRROR TOILET PAPER HOLDER W/0 STOPS PLACEMENT SHALL NOT PREVENT U5E OF GRAB BAR 36' MIN. 24' FOLD DOWN BABY CHANSIN6 STATION 6' MAX. WALL - MOUNTED WATER CLOSET 4 GRAB BARS 5117E VIEW WALL- MOUNTED WATER CLOSET 4 GRAB BARS FRONT VIE1 TOILET ACCESSORY MOUNTING DETAIL z f in N \ \ SURFACE MOUNTED TOILET PAPER DID SURFACE MOUNTED TOILET SEAT DOVER DISPENSER SURFACE MOUNTED SHELF m 0 MOP AND BROOM GOAT HOOK BRACKET FIRE HOLDER EXTINSUISHER RECEPTACLE THERMOSTAT DRINKING FOUNTAIN ADA MOUNTING HEIGHTS SCALE: NOT SCALED 4 O BARRIER FREE S• SIGN � "-Jr WALL BASE LINE OF CEILING BEYOND SOLID GORE WOOD DOOR ADA SIGNAGE MOUNTING LOCATION SCALE: I/2 ": ILO° 1 0 1 2 4 FT. Jil''aW, 1' -0" FLOOR CLEARANCE SPACE TYP. SEMI - RECESSED PAPER TOWEL DISPENSER PV WASTE RECEPTACLE LAVATORY W/ INSTA -HOT 1' -3" SOAP DISPENSER 24X56 MIRROR SANITARY SEAT DOVER DISPENSER RESTROOM ENLARGED FLOOR PLAN SCALE: 1" = 1'-0" 6' STAINLESS STEEL GRAB BARS - PROVIDE BLK6. TO SUPPORT 250* LOADING PROVIDE SPRINKLER HEAD 4 FIRE ALARM DETECTOR DEVICES PER CODE REQ'T NEW GYP. BD. CEILING, 0 S' -0' 1 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 17 2011 City of Tukwila BUILDING DIVISION RECESSED IX4 FLOURESGENT LIGHTING FIXTURE W/ ACRYLIC LENS DOVER. TYP. O2 RESTROOM REFLECTED CEILING PLAN SCALE: I' = I' -0" RECEIVED NOV 07 2011 PERMIT CENTER 425 827 2100 z 0 98033 wwwwFH 0 0 w 40 5209 Lake Washington Blvd NE .12 CSC in rg 0 C3 z J 7812 REGSTERE:E; ARCHi ;TC- REV DESCRIPTION 1 THOMAS /C SPARER STATE OF NA,SH!NGTON RESTROOM PLANS/ DETAILS DATE A6.0 PROJECT NUMBER: A11.484 11102111 ® FREIHEIT & HO ARCHITECTS, INC., P.S. TO 5Tr W TURF ABOVE MAIN RUNNER GROSS RUNNER INSTALL *12 6A VERTICAL WIRE AT 4' -0" O.G. CONNECTED TO MAIN RUNNER AND STRUCTURE ABOVE. INSTALL *12 6A. WIRE GROSS BRACING IN EACH PLANE OF MAIN RUNNER AT 12-0' O.G. AT 45 DEGREE SHALL BE ANGLES IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6'-O" FROM EACH WALL. INSTALL A STRUT (I 5/8° MINA ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRES. THESE 45 HORIZONTAL RESTRAINT POINTS SHALL BE PE X E5 PLACED 12 FT (3658 MM) ON GENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN 6 FT (18241 MM) FROM EACH WALL. NOTE: 1. INSTALL AS REQUIRED UNDER ASTM E580, ASTM G635 AND ASTM 6636. 2. SUPPORTING WIRES TO BE GAUGED AND SPADED PER ASTM 0841 TABLE 3. 3. PROVIDE LIGHT FIXTURE SUPPORT ATTACHMENT PER ASTM E580. CEILING SPLINE BRACING ITT J SCALE: NOT TO SCALE 10 &A HANGER WIRES AT 4' -0' ON CENTER MAXIMUM EACH WAY (TYPICAL) CONTINJOUS ANGLE AT WALL EDGE TYPICAL 8' MAX. 10 6A WIRE HANGERS AT PERIMETER SUPPORTING MAIN RUNNERS AND GROSS RUNNERS an MAX FROM EDGE. RECESSED LIGHT FIXTURE WHERE OCCURS 10 GA LATERAL BRACING WIRES 2' -0' MAXIMUM FROM CHANNEL INTERSECTION AT APPROXIMATELY 45° IN EACH DIRECTION. LOCATED ON A 8' -0" X121-0" O.G. GRID AND A MAX. 6' -0' FROM WALLS. NOTE: PROVIDE I" X 2' CLOSURE ANGLE AROUND PERIMETER AT WALLS. MAIN RUNNERS: I I/2" GOLD ROLLED GHANNEL5 AT 4' -0' ON CENTER MAXIMUM V8" X 22 6A GALV. HAT FURRING CHANNEL AT 16" O.G. MAX. ACOUSTIC CEILING ACOUSTICAL CEILING GRID SUPPORT AT•O SCALE: NOT TO SCALE NEW EXIT LIGHT NEW BUILDING STANDARD CEILING TILE AND GRID 0 10' -0' Al. F EXTEND FIRE SPRINKLER SYSTEM AS NECESSARY. NEW 2X4 RECESSED FLUORESCENT LIGHTS, TYP. NEW GYP. BD. CEILING ® 8' -0" AND LIGHTING COpEC� �F APPROVED FOR ROVED NOV 17 2011 BUILDING City DIVI5ION NEW EXIT LIGHT 1 ;(p 2.. RECEIVED NOV 0 7 2011 PERMITCENTER 'S' BU I/4 °= II' L-0DING REFLECTED CEILING PLAN @ SUITE 116 SCALE: ° 1 1 N 0 1 2 4 8 FT. 98033 wwweFHOARCH.COM TEL; 425 827 2100 5209 Lake Washington Blvd NE 1 Ste 200 a mime u 1 REV DESCRIPTION REGISTERED ARCHITECT a / d THO� r . SPADER STATE OF ■"'ASH■NCTON REFLECTED CEILING PLAN DATE A7.0 PROJECT NUMBER: A11-484 11/02/11 ® FREIHEIT & HO ARCHITECTS, INC., P.S.