Loading...
HomeMy WebLinkAboutPermit D11-364 - VAUGHN RESIDENCE - CARPORTVAUGHN CARPORT 4531 S 137 ST Dl 1-364 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7347600410 Address: 4531 S 137 ST TUKW Suite No: Project Name: VAUGHN CARPORT DEVELOPMENT PERMIT Permit Number: D11 -364 Issue Date: 02/10/2012 Permit Expires On: 08/08/2012 Owner: Name: VAUGHN PAUL Address: 4531 S 137TH ST , TUKWILA WA 98168 Contact Person: Name: PAUL VAUGHN Address: 4531 S 137 ST , TUKWILA WA 98168 Phone: 206 349 -7962 Contractor: Name: OWNER AFFIDAVIT - PAUL VAUGHN Phone: Address: Contractor License No: Expiration Date: Lender: Name: Address: DESCRIPTION OF WORK: CONSTRUCTION OF DETACHED CARPORT (206 SF) WITH ENCLOSED STORAGE ROOM BEHIND (112 SF). Value of Construction: $13,518.18 Fees Collected: $945.78 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 26 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -364 Printed: 02 -10 -2012 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N Permit Center Authorized Signature: Private: Profit: N Private: Public: Non - Profit: N Public: W c A Date: f)---10— I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this pernfit. Signature: Print Name: RCLuA, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. G44,1■3 Date: PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431 - 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for special inspection. doc: IBC -7/10 D11-364 Printed: 02 -10 -2012 7: All wood to remain in placed concrete s e treated wood. i 8: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -364 Printed: 02 -10 -2012 CITY OF TUKTA Community Developr,..,.d Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 4c-51 Tenant Name: Name: Address:(kc �. tr "2J State: (4..) (5% Zip. k L/e) . ,,, ,n Name: 1 Cam\ Wit~ L,>v Architect Name: Address: ( I City:. ice`, wAes, State:Co A Zipoic2,t( Phone ct _--1 etteiax: City: Email: L.A ` / l 3- /) C7 +MCA c Zip: Company Name: Address: City: e_ State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:Wpplications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh King Co Assessor's Tax No.: 9)4 1 ( Do — oLt I'd Suite Number: Floor: New Tenant: ❑ Yes ❑.. No Company Name: N , Architect Name: Address: City: State: Zip: Phone: Fax: Email: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: Page 1 of 4 iloa>co" o�a3�l36T �r .ems Valuafio`n'of =Project (contractor's bid prieW $ 4 500. t Existing building Valuation: $ , Describe,theFscope of work (please provide detailed information): Ae-ce e kAea CAS '('- C204 Sc6 Will there be new rack storage? ❑ .... Yes X.No If yes, a separate permit and plan submittal will be required. :'S .iC !°a$, j "" tvE.f'TF #>xe .may ,>.y. "; i+ ' it`2vi"r�am. � ✓,�, ' , �;-,, ;Y,u ,' n Y � at' . t :4xfy. r� � 1'li mt4 k '3'" C k.+i'ut doh zri' ° . , &t .Y%_ " ,Ex'x�t"�$�''" , . x i sttn i' mF} ...•,}.� :.�IaY �M" .. d'K k.r: t, • . `�Y� �' t'zwz: s u 3LS�q 050 O. 4;Y ,' . ".`s a^u t ?.� ^"3 Ex>sh n"�e fi. 'ii x " "�.:i^�iPt 'Y' , �', Y - i� 1� ... ti pt +�' "> $f Y:, i' ,at,. e Qcc-:{u p'a?r InB.rB -c_y errJ?r , i „......,4.e4:„ z h•.-;. n„ trictur i151 o Flor o„r..� �7 IL�.1� ,.E 3�4f...i.l•,36�%Y��c7 =.-�- r>�.:.Y.nf �'.r Floor t y, Float�``,``::thru Basetnent Acces mss., t� �' rte, '',� �ji !�35 mnT i r k Y A�ttached �rage� � y�;`,� S ',Oa-16 u eGa age�f :` "fly. }v''"''��f�v'ix{ Attaehed Carpor ” r +111 Vt t u avetei #7Dk� , Uf }{� Sc c��fj�— :.s'W"iT"XESyiY`6 ' PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? Compact: Handicap: ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No If 'Yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Sa ty ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line12011 Applications\Permit Application Revised - 8 -9 -11. does Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value' construction amount should be entered by the applicant. This figure will be reviewed and is subject , to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI NER11OR` AUTHORIZED AGENT: Signature: G �l Print Name: Tetm..k V e , L r..3 Mailing Address: 4 \. 5, I3"1 -rt„ ( . H:\Applications\Forms- Applications On Line\201 I Applications\Permit Application Revised - 8-9-11 docx Revised: August 2011 bit Date: I \ I y-' l \ Day Telephone: 2C7(.r3tA — �%(pZ \LA4.0AcA Wc, 9 `6(CP City State Zip Page 4 of 4 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7347600410 Address: 4531 S 137 ST TUICW Suite No: Applicant: VAUGHN CARPORT RECEIPT Permit Number: D11 -364 Status: APPROVED Applied Date: 11/08/2011 Issue Date: Receipt No.: R12 -00602 Initials: User ID: Payee: WER 1655 Payment Amount: $714.90 Payment Date: 02/10/2012 04:04 PM Balance: $0.00 PAUL VAUGHN TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4063 714.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 710.40 640.237.114 4.50 Total: $714.90 doc: Receiot -06 Printed: 02 -10 -2012 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 7347600410 Address: 4531 S 137 ST TUKW Suite No: Applicant: VAUGHN CARPORT RECEIPT Permit Number: D11 -364 Status: PENDING Applied Date: 11/08/2011 Issue Date: Receipt No.: R11 -02442 Initials: User ID: JEM 1165 Payment Amount: $230.88 Payment Date: 11/08/2011 10:27 AM Balance: $714.90 Payee: PAUL R. VAUGHN TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4058 230.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 230.88 Total: $230.88 doc: Receiot -06 Printed: 11 -08 -2011 INSPECTION RECORD Retain a copy with permit i -3(.4 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3671 Permit Inspection Request Line (206) 431 -2451 PERMIT NO. Project: _ U c, tt- AI arpo,--11 Type ct_ iqn: j 6 \ Address ')3 I . 13�- Date Called: Special Instructions: • � Date Wanted:- .� .-------- A 1 ��a,u�t p.m- Requester: P ?. &°:— .34/ --17` ? Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 5-- (1j -1)" ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 P— D11-361 Project: IJAu6ft k/ (f p � r Typgof Inspection. 1 ! hk.. ' t,c j 44A SGk e/4 Address: Pt. �#53i 131 sr Date Called: Special Instructions: �• Date Wanted:. �` a 3 - 13 _� Z p.m. Requester: Phone No Z0 6 --7? 'Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Inspect Date: "—I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. I. • 6. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1'(206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �1 t —3i C Project JOA �NAi C-10 r( Type o _Inspection: ro o( ., P--06F Address:,. _ Date a d: Specia l Instructi8ns: Date Wanted:. - 7 �.,a..� 2 -Fr -I L• P.m. Requester: Phone No: • pproved per applicable codes. E Corrections required prior to approval. Z. COMMENTS: 7 Inspec or: Date:2 2 _ REINSPECTION FEE REQUIRED. rior to next inspection, fee must be paid at 6900- Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION 0. INSPECTION RECORD Retain a copy with permit 0 It -361 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Projec : / �J .A, l)& / p (J\ pJ% 1 Type of Inspection: Re J-4,0 Jc S� J� Address: -1 3 ' 3 �l f ST Date Called: Special Instructions: Date Wanted: / 2 ( . a rq. Z p.m. Requester: Phone O b r .34 — Cr Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ins ector: ❑ REINSPECTION FEE REQUIRE'. Prior i next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD approved By:, Date:,- -� ---1— 4531 S. 137th St. Tukwila SEPARATE PERMIT REQUIRED FOR: ei rectrical @ft'tumbing lirtas Piping City of Tukwila BLiii_DINO DIVISION Property , ine Retaining Wall r - COPY Pe Rio., — 3 (04 Ph^ r^view approval is subject to errors and ora tors. k: ` o construction documents does r;oi auttnize o3 any adopted code or ordinance. Reo :pt C Lppro Copy and conditions is ac know1edg :d: By. �� \)c-k4-60 Dete: , 21k0 11Z City Of Tbkwile BUILDING DIVISION U, REVISIONS No chenpes shall be made to the scope of work 1"ithout prior approval of Tuk". Lila Building Division. will require a new plan submittal may include additional plan review fees. Macadam Road S lawn LET S EVIEWED FOR DE COMPLIANCE APPROVED FEB 0 3 2012 v City of Tukwila B ILDING DIVISION RECEIVED CITY OF TUKWIIA NOV 0 8 2011 PERMIT CENTER I Ridge Be 2x10 4531 S. 137th. St., Tukwila, 98168 Side View 2x6 Ceiling Jois p.L. 2x4 wall studs. IV O.L. 2x4 Treated Sill Plate � ,2 x8 Roof Rafters 2x4 Barge,Rafte i r ., r Is 3r4 "poard r „ , r 1I .. ._,...�, I I 1 1 I 1 to to lo o I. o 1 0 I Foam Seal Sill Anchors Wall Sheathing 1/2" T -111 4531 S. 137th St., Tukwila 98168 Existing Structure Top View 112 sq. ft. 9• 17 6° 16'6^ 206 sq. ft. 6' REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 3 2012 . I City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKIMLA NnV 0 8 2011 PERMIT CENTER FILE COPY Permrt 4531 S. 137th St., Tukwila, 98168 Foundation Plan Anchor Bolt Spacing 4' O.C. Anchor Bolt 5/8" diameter 8" imbedment P. T. Sill Plate Foam Seal REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 3 2012 City of Tukwila BUILDING DIVISION 1< 2 Bolts Per Plate Section W/ One Bolt Located 8" from End Of Plate 5/8" Galvanized Nut Galvanized Washer (2) #4 Continuous #4 16" O.C. CITY REC OF t�V Tu LA JAN' 13 2012 PERMIT CENTER I INCOMPLETE (01-1 4531 S. 137th St., Tukwila, 98168 Typical 3 Tab Asphalt Roofing 40 lb. Felt Paper 5/8" OSB Roof Sheathing p. 2x8 Roof Rafters „2• Plywood Flooring A,..-- Continuous Ridge Vent 2x10 Ridge Board \■ x Dt_2x4 Studs 2x4 Top Plates 4x8 Headers Over Interior Doors (-5/8" T -111 Siding 2x6 Ceiling Joists 2/4 Bottom Plate P.T. Sill Plate 2x4 On Foam Seal Anchor Bolt: 10x5/8" Diameter With 8" Embedded, 1/4" Galvanized Washer, 5/8" Nut Concrete Slab EXPIRES 1-/S-- 2c '3 j Introduction FILE COPY PermQ ®. Lateral Load Evaluation For Building At 4531 S. 137th St Tukwila, WA 98168 By Henry J Welland PE REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 3 2012 City of Tukwila BUILDING DIVISION Page 1 of 40 CITY OF WALA JAN' 13 2012 PERMIT CENTER INCOMPLETE LTR# P11 -3(,y Evaluation: a1110=1.111111■+ rf Introduction The building is a 12 1/2 foot wide by 25 1/2 foot long with a 16 1/2 foot deep walled carport on one end and a 9 foot deep room on the other end. The walls are 10 foot high and the roof slope is 12:12. The building is sided with T -111 plywood siding, roofing will be asphalt composition roofing. Building walls are 2x4 with16 inch spacing. Roof rafters are 2x8 at 24 inch spacing. Ceiling joists are 2x6 at 24 inch spacing. The rafters and joists are connected at the ends above each side wall. Each rafter /joist is connected to the side wall top plates with metal clips. The sill plate is bolted to the concrete slab with 1/2" diamater bolts at 4 foot spacing. The roof is sheathed with 1/2 OSB and the attic floor with 1/2 plywood. There is a 2 foot by 3 foot opening in the attic floor in the center about 5 foot from the back wall. The inside wall on the 9 foot room has 2x4 studs with 1/2 plywood sheathing on the carport side of the wall. A 3 foot wide by 7 foot tall door is installed on the side of the inside wall. The slab is concrete 12 1/2 foot wide by 25 1/2 foot long 4 inch thick with a 2 1/2 inch high by by 6 1/2 inch wide curb on the 2 long sides and the back (opposite of carport entry) end of the slab and a 16 x18 footing aroung the edge. This evaluation examined the lateral support requirements based ASCE -7 -10 and the 2008 edition of Special Design Provisions for Wind and Seismic and recommend any modifacions necessary to ensure the building meets all of the requirements. Lateral seismic loads were insignificant compared to wind loads. The structure was analyzed for the loads applied by wind and the structural requirements were reviewed for both wind and seismic requirements. The following building modifications are required to provide adequate lateral support. Page 2 of 40 :i,I.Wikifs,sMi 1:3 -3i.1Q 5i1�1 ::i'!-1 ti Install hold downs at wall ends: stud Introduction Install 1/2" dia carbon steel anchor bolt and holddown at each stud location shown (10 places) Strongtie DTT2Z holdown (allowable load =1825 lbf) 1/4 x 1 1/2 SDS screws (8 places) Red Head Trubolt Wedge Anchor 1/2 dia x 8" long w /nut and washer (allowable load =1575 lbf) sill plates 4 1/8 inches oncrete slab /foundatio Page 3 of 40 ./ 1 Introduction Structure to resist vertical up load on short internal wall When the wind is from the side that causes the framing on the side of the door to be loaded in tension, structure is required to carry the load over to the outside wall on the other side of the door. Install an additional attic joist adjacent to the joists on each side of the internal wall. Install 2 - 2x6 cross ties to connect the end of the wall just above the side door frame to each of the built up joists as shown below. Note A Rafters � C install 1/2 dia bolts nuts and washers each side of cross tie, each set of joists 1" edge margin, 6" spacing (8 bolts total) New 2x6 joists Top of internal wall Install 2 - 2x6 cross ties centered above 3 studs at top of door (approx 3 ft from outside wall) Install joist hanger installed to accept vertical up load (upside down) (Simpson LUS26 -2 - 1684 lbf wind load) Note A - install hurricane clips same as on existing joists on each end of each new joist. (Simpson H2.5 - 415 lbf uplift) Page 4 of 40 r Attic floor and joists Introduction install 2x6 blocking between opening in floor joists each side of opening MINN =IN III=111 ■ add 2x6 blocking at all panel edges 8d nails 6" spacing all panel edges 12" spacing field nailing Internal Wall Introduction add 2 x 4 blocking at edge of panels 8d nails at 6" spacing all panel edges 12" spacing at remaing studs Page 6 of 40 Wind Load Evaluation: Parameters From ASCE -7 -10 Building Risk Category Basic Wind Speed (V) Wind I or II Table 1.5 -1 110 Figure 26.5 -1A for Category II 100 Figure 26.5-1C for Category I Wind Load Parameters kd 0.85 Table 26.6 -1 and Section 26.6 Exposure B Section 26.7 Kzt 1 Sect 26.8.2 Enclosure Classification Part encl Section 26.10 GCpi 0.484461 Table 26.11 -1 and Sect 26.11 - 0.48446 Kz 0.7 Table 28.3 -1 qz 18.43072 Eq 28.3 -1 GCpf varies Fig 28.4 -1 wind pressure (p) varies Eq 28.4 -1 Worst load combination for lateral loads on building from Chapter 2 Section 2.4.1 Load combination 5 D +.6W Calculation for exposure classification Ao = 125 Aroof = 450.7806 Aside = 510 A back = 164.0625 Ag = 164.0625 Aoi = 2.6 Agi = 1124.843 reduction factor for GCpi 0.880839 Page 7 of 40 1.1Aoi = 2.86 Aoi /Agi = 0.002311 Partially Enclosed Wind Estimate wind load on long side of garage: This orientation will result in highest diaphragm loads Length of garage = 25.5 ft 12 12 1 6.25 ft 1 10 ft 12.5 ft Page 8 of 40 Load Case A from Figure 24.4 -1 a =3ft h= 13.25 ft -0.48 -0.37 -0.48 open end — 0.69 wind direction -0. 7 windward corner 0.69 Wind Page 9 of 40 p1 1.392232 19.25017 P2 1.392232 19.25017 p3 - 15.7483 2.109605 p4 - 15.7483 2.109605 p 1 E 3.788226 21.64617 p2E 3.788226 21.64617 p3E - 17.7757 0.082225 p4E - 17.7757 0.082225 Roor horizontal and WL2v = 8101451 WL2h = 8/01451 WL2Ev = 23.67641 WL2Eh = 23.67641 Wind P3 = 15.74834 psf P3 = - 2.1096 psf L3 = 8.838835 ft P4 = 15.74834 psf P4 = - 2.1096 psf L4 = 10 ft P2 = 1.392232 psf P2 = 19.25017 psf L = 8.838835 ft / main wall P3E = 17.77572 psf P3E = - 0.08223 psf P4E = 17.77572 psf P4E = - 0.08223 psf vertical loads: 120.3136 lbf/ft 120.3136 lbf/ft 135.2885 lbf/ft 135.2885 lbf/ft P1 = 1.392232 psf P1 = 19.25017 psf L1 = 10 ft P2E = 3.788226 psf P2E = 21.64617 psf edge (6 ft long) P1 E = 3.788226 psf PIE= 21.64617 psf WL3v = 98.42711 13.18503 lbf/ft WL3h = 98.42711 13.18503 lbf/ft WL3Ev = 111.0982 - 0.51391 lbf/ft WL3Eh = 111.0982 - 0.51391 lbf/ft Wind Side wall upper and lower end loads: W L 1 = 6.961161 96.2 5087 lbf/ft WL4 = 78.74169 - 10.548 lbf/ft WL1 E = 18.94113 108.2308 lbf/ft WL4E 88.87858 -0.41113 lbf/ft Horizontal load on upper edge of side wall from wall and roof horizontal loads: left right 1st 6 ft of wall (or last 6 ft for wind at opp corner) Pupr 199.9768 - 0.92504 42.61754 243.5194 lbf/ft 19.5 ft of wall Pupr = 177.1688 2.637006 15.66261 216.5645 lbf/ft Vertical Loads on wall from roof 1st 6 ft of wall (or last 6 ft for wind at opp corner) 19.5 ft of wall The wind load with the negative CGpf with the wind shear wall ( rear wall and interior wall at 9ft from ba Horizontal load at top of wall Pv : 111.0982 - 0.51391 23.67641 135.2885 1bf /ft 98.42711 13.18503 8.701451 120.3136 1bf /ft from the side results in the highest load on the the short ck). = 242.5944 lbf/ft for 6 foot at windward corner 219.2015 lbf/ft for remaining 19.5 ft of wall The windward corner loading long side shear wall, and the the highest shear loading on The left side vertical load is The right side vertical load is at the open end will cause the highest loading in the windward corner loading on the back end will cause the short shear walls. 0.513909 lbf/ft down on the windward corner section and 13.18503 lbf/ft up on the remaining wall 135.2885 lbf/ft down on the windward corner section and 120.3136 lbf/ft down on the remaining wall Page 11 of 40 • Wind Reaction loads on walls parallel to wind load will be proportional to length of wall to any opening: Back wall = 12.5 ft Intermediate wall = 9.5 ft => length of wall - width of door fraction of load in back wall = fraction of load in intermediate wall = 0.568182 0.431818 horizontal loads on shear walls for design purposes Total transverse load = 5729.995 Ibf Rswb = 3255.679 Ibf = 242.5944 lbf/ft ww = 219.2015 Ibf /ft 19.5 Page 12 of 40 Rshi = 2474.316 Ibf Diaphragm with max load on long shear walls moment = 52157.07 ft-lbf Rswb = 3255.679 lbf = 2474.316 lbf 4 I- 4- 4- 4- 4- I 4- 4- 4-- 4- 4- 4- 4--- • 4- Top Plate Load = Chord stress = 4172.566 lbf 397.3872 psi Wind 9ft 16.5 ft 1 w11 = 219.2015 lbf/ft 6ft w12 = 242.5944 lbf/ft Horizontal Diaphragm: Diaphragm nail loads 1/2 inch plywood on 2x6 joists, blocking at all panel edges From moment loads = From transverse loads = Total Nail Load = 163.63 lbf/ft 300.5745 lbf/ft 342.2277 lbf/ft peak shear load at internal wall Use 8d nails - 6 inch spacing Wind Nominal shear value for 15/32 wood structural panel with 8d nails spaced at 6" vs = 755 lbf/ft Table 4.2A SDPWS ASD factor = 0.5 Sect 4.2.3 SDPWS allowable load = 377.5 lbf/ft Weight of building and foundation: Roof: multiplier for sloped roof = 1.414214 asphalt shingles 3 lbf/ft2 4.242641 lbf/ft2 felt 1 lbf/ft2 1.414214 lbf/ft2 sheathing 5/8 OSB 1.875 lbf/ft2 2.65165 lbf/ft2 Rafters 2x8 @ 24 oc 1.451059 lbf/ft2 2.052107 lbf/ft2 attic decking 1/2 plywood 1.5 lbf/ft2 attic joists 2 *6 @24 oc 1.1228 lbf/ft2 total weight of roof 4138.462 lbf ridge beam 2x10 3.372 lbf/ft roof load per foot per side 82.83232 lbf/ft Add 25% for nails, blocking and misc 20.70808 lbf/ft Roof load onto top of wall 103.5404 lbf/ft Page 14 of 40 Wall Top plates 2 -2x4 studs 2x4 @ 16 oc Bottom Plate 2x4 T -111 siding total wall weight per foot add 25% for misc Total weight of wall per foot Slab Slab weight per foot on each side density = 145 Ibm/ft3 Wind 2.552 lbf/ft 10.50824 lbf/ft 1.276 lbf/ft 11.25 lbf/ft 25.58624 lbf/ft 6.396559 lbf/ft 31.98279 lbf/ft 309.8032 lbf/ft Gable end wall weight per foot = 41.97742 lbf/ft Page 15 of 40 Wind Net loads on top of foundation due to gravity includin wind vertical loads (wind from side) Fnd r = 122.3382 lbf/ft Fnd I = roof + wall + wind = 255.8368 Ibf /ft Side wall shear panel: I r 10 ft 1 25.5 ft --� wt = 255.8368 lbf/ft 111111111111111 right side wall Wind P = 4172.566 lbf Overturning moment = 41725.66 ft-lbf restoring moment = 83178.94 ft-lbf Therefore hold downs not required Load on comp chord = 1636.3 lbf Load on corner studs = 1977.416 lbf stress in 3 studs = 125.5502 psi shear /ft = 163.63 lbf/ft wall & roof load is more than enough resist tension load Nominal shear value for 3/8 wood structural panel with 8d nails spaced at 6" vs = 730 lbf/ft Table 4.3A SDPWS ASD factor = 0.5 Sect 4.3.3 SDPWS allowable load = 365 lbf/ft Left side wall: restoring moment = 39775.2 ft-lbf still larger than overturning moment so no hold down require. Page 17 of 40 Wind End wall Shear wt = 41.97742 lbf/ft i 10 ft 1111111111! 12.5 ft Rc = 2866.902 lbf shear /ft = 260.4543 lbf/ft d R t = 2342.184 lbf Horizontal 3255.679 lbf shear on foundation bolts = 3255.679 lbs bolt allowable = 5 bolts installed = => Nominal shear value for 3/8 wood structural panel with 8d nails spaced at 6" Table 4.3A SDPWS Sect 4.3.3 SDPWS vs = ASD factor = allowable load = 730 lbf/ft 0.5 365 lbf/ft Page 18 of 40 665 Ibf 3325 lbf capable Internal end wall shear 1 10 ft Wind L = 31.98279 Ibf /ft 111111111 9.5 ft = 2474.316 lbf Rc = 2756.461 Ibf Rt = 2452.625 Ibf shear /ft = 260.4543 lbf/ft shear /ft = 275.6461 Ibf /ft shear /ft = 245.2625 Ibf /ft top and bottom edge compression edge tension edge Nominal shear value for 15/32 wood structural panel with 8d nails spaced at 6" vs = 730 lbf/ft Table 4.3A SDPWS ASD factor = 0.5 Sect 4.3.3 SDPWS allowable load = 365 lbf/ft Page 19 of 40 Wind Structure to resist wall uplift when wind load is from left rather than right: Because of the door on the left side of the inner wall, the tension load occurs about 3 ft from side wall. The slab is not thick enough to use a hold down to resist the entire 2452.625 lbf load. A floor anchor will hold a total of 490 lbf. The remainder will be transferred to the outer wall by attaching a cross tie above the end of the door frame to the joists on each side of the inner wall and the shear wall section above the door. RI1 12.5 ft 12 9.5 1962.625 lbf Rr1 RI1 = RI2 & Rr1 = Rr2 RI1 = 745.7974 lbf Rr1 = 235.515 lbf Cross Tie: 2 - 2x6 DF Bearing load at top of wall brg stress = 186.9166 psi brg allowable stress= 831.25 psi 1962.625 lbf Page 20 of 40 21 in PI = Pr = M max = S= stress = 2x6 DF std lb = shear stress = allowable = 981.3124 lbf 10303.78 in-lbf 7.5625 in3 681.2417 psi & btr allow 2074.8 psi 178.4204 psi 252.7 psi Load on joist: Wind 745.7974 Ibf 235.515 Ibf 981.3124 Ibf M max = Stress = 26848.71 in-lbf 3550.242 psi 1775.121 psi 1 joist per side 2 joists per side Install an additional joist on each side of the inner wall and install a cross tie to distribute the load to each set of 2 joists. Install 2 1/2 inch bolts on load per bolt = 245.3281 lbf each side of cross tie attachment point allowable load per bolt= 576 lbf Concrete Slab Load * 490 lbf affected length of concrete slab = 91.24138 in moment at end of affected length. 1862.845 in -Ibf moment at center = - 3725.69 in-lbf we = 5.37037 lbf/ft Page 21 of 40 Wind allowable tension in concrete = 88 Ibf /in2 Section Modulus of affected slab: 42.66667 in3 max allowable moment = 3754.667 in-lbf Portion of load carried by end of shear wall: 3 T= 781.3629 approximate shear load = load carried by joists = 260.4543 Ibf/ft 1181.262 lbf deflection of joist at point of load application: 0.295225 in the joists can carry the total load if required, but the floor anchor, and wall above door, can work together to minimize the deflection on all members to ensure no objectional damage during peak wind loads. Page 22 of 40 Foundation Loads: P= Wind 25.5 ft P2 = 2452.6251bf P1 = 2342.184 lbf 343,z „i,ifaa- ,ft I i 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Load = 309.8032 lbf/ft span 1 = span 2 = 25.5 ft 16.5 ft P1 concrete conditions: L affected concrete = 4.140768 ft end reaction of affected footing = P - wL = 0 lbf moment at end of affected concrete (PL- wL ^2/2) *12 = 58190.65 in -Ibf footing width = footing height = c= 1= allowabe tensile stress = 18 in 16 in 8 in 6144 in4 88 psi Max allowable moment = 67584 in-lbf Page 23 of 40 E Wind P2 concrete conditions: L affected concrete = 4.336017 ft moment at end of affected sections = 5317.311 in -Ibf moment at center of effected section = - 10634.6 in-lbf Max allowable moment = 67584 in -Ibf Page 24 of 40 Wind Y Deflection of Shear Walls and Diaphragm: see SDPWS 4.2.3 & 4.3.2 horizontal diaphragm A = area of chord (in2) 10.5 in2 W = diaphragm width (ft) 12.5 ft E = elastic modulus (lbf/in2) 1800000 lbf/in2 Ga = mod of rigidity (lbf/in2) 9.5 lbf/in2 L = diaphragm length (ft) 25.5 ft v = shear load (lbf/ft) 300.5745 lbf/ft sumdx = sum of chord splice slip (in) 0.1104 in deflection = 0.325286 inches shear walls side rear internal A Area of boundary element (in2) 10.5 10.5 10.5 in2 b wall width (ft) 25.5 12.5 9.5 ft da deflection due to anchorage (in) 0.06 0.06 0.06 in E elastic modulus (lbf/in2) 1800000 1800000 1800000 lbf/in2 Ga mod of rigidity (lbf/in2) 12 12 10 lbf/in2 h wall height (ft) 10 10 10 ft v shear load (lbf/ft) 163.63 260.4543 260.4543 lbf/ft deflection 0.162604 0.273865 0.335217 in max deflection of front edge of roof = 0.697859 in Deflection must not be more than 1/2 the thickness of the wall which is 3.5 inches Page 25 of 40 2ft x 3ft opening in horizontal diaphragm 4172.566 Ibf • Wind 4 25.5ft 210IbrX1111111111111111111 414Ullii 3 ft —1 4172.566 Ibf 3255.679 Ibf 5ft t 2474.316 Ibf 2ft 242.5944 If /ft 1 12.5 ft shear di agram 260.4543 Ibf /ft R 1 102.6292 Ibf /ft 300.5745 Ibf /ft 137.7015 lbf/ft 172.7737 Ibf /ft shear diagram 116.4453 Ibf /ft Page 26 of 40 _163.63 lbf/ft q = 3255.679 <x > ^ -1 - 219.202 <x > "0 -V = 3255.679 <x > "0 - 219.202 <x> M = 3255.679 <x> - 219.202/2 <x > "2 X -V M TorC 0 3255.679 0 0 3 2598.074 9767.036 781.3629 5 2159.671 16278.39 1302.272 6 1940.47 19534.07 1562.726 7 1721.269 22789.75 1823.18 9 1282.866 29301.11 2344.089 a 1079.836 Ibf 227.3338 Ibf /ft b ra Wind Ibf /ft n op Ibf /ft open 260.4543 207.846 172.7737 227.3338 155.2376 204.26 137.7015 181.1862 102.6292 a = 1358.466 Ibf b = 204.26 Ibf c 219.2015 Ibf /ft 1562.726 Ibf i 4.75 ft 970.235 Ibf 204.26 Ibf /ft Page 27 of 40 1562.726 Ibf 970.235 Ibf 204.26 Ibf /ft 6 0 a = 1766.986 Ibf b = 204.26 Ibf t c • 1079.836 Ibf 227.3338 Ibf /ft 5 6 ■ IV i. Wind 219.2015 Ibf/ft i 4.75 ft 860.6343 Ibf 181.1862 Ibf/ft 0 0 Ibf d = 1335.392 Ibf c = 227.3338 Ibf t 1 4.75 ft 970.235 Ibf 204.26 Ibf /ft 1562.726 Page 28 of 40 970.235 Ibf 204.26 Ibf /ft 1562.726 4_____ 6 ■ 0 a d = 1743.912 Ibf c = 181.1862 Ibf c 4-- I. c d Wind 1 4.75 ft 860.6343 Ibf 181.1862 Ibf /ft Chord Forces w/o opng w opng change 5a 1302.272 C 1358.466 C 56.1943 C 5b 0 204.26 C 204.26 C 5c 0 227.3338 T 227.3338 T 5d 1302.272 T 1335.392 T 33.12046 T 7a 1823.18 C 1766.986 C 56.1943 T 7b 0 204.26 T 204.26 T 7c 0 181.1862 C 181.1862 C 7d 1823.18 T 1743.912 T 79.26814 C Page 29 of 40 Shear w/o opng change resultant 3 a -b 207.846 28.09715 235.9431 b -c 207.846 130.2272 338.0731 c-d 207.846 16.56023 224.4062 5 a -b 172.7737 28.09715 200.8709 b -c 172.7737 130.2272 303.0009 c -d 172.7737 16.56023 189.334 7 a -b 137.7015 - 28.0972 109.6043 b -c 137.7015 - 130.227 7.474331 c -d 137.7015 - 39.6341 98.06741 9 a -b 102.6292 - 28.0972 74.5321 b -c 102.6292 - 130.227 - 27.5979 c -d 102.6292 - 39.6341 62.99518 Wind Page 30 of 40 F b m d 243.65 84.26 198.39 168.21 Wind 84.26 168.52 148.67 87.95 ca 9 243.65 57.77 173. 4 94.19 53.58 47.85 74.34 3.69 233.7 158.28 148.67 78.002 252.47 168.52 282.65 188.38 188.46 Page 31 of 40 82.81 -26.49 Wind Shear stresses in blocking between 3/5 and 7/9 sum forces horizonal = F35 +F56 + F67 + F79 - F'79 - F'35 F'35 = F'79 F'35b = F'35c = 571.56 571.575 lbf shear = lbf shear = 285.78 lbf/ft 285.7875 lbf/ft Blocking from 3 through 9 will tranfer any increase stresses from opening Page 32 of 40 Wind Estimate windloads with wind parallel to the ridge line of the roof: -0.53 -0.48 0.4 -0.45 -0.37 - 0.29 0.61 wind direction windward corner same - 1.07 - 0.48 Load Case B - Fig 28.4 -1 -0.43 rev Page 33 of 40 rev Wind Horizontal loads on upper end of side walls: left wall right wall windward edge= 17.77572 - 0.08223 17.77572 - 0.08223 psf away from edge= 17.22279 - 0.63515 17.22279 - 0.63515 psf Load on upr end windward edge= 88.87858 - 0.41113 88.87858 - 0.41113 lbf/ft away from edge= 86.11397 - 3.17573 86.11397 - 3.17573 lbf/ft Total Load on upper edge of wall - wall and roof horizontal loads windward edge= 205.7364 4.834564 267.9401 67.03824 lbf/ft away from edge= 184.5411 - 16.3608 221.4025 20.50068 lbf/ft Horizontal Load on Diaphragm: windward edge= 62.20368 62.20368 lbf/ft away from edge= 36.86144 36.86144 lbf/ft These loads are significantly lower than winds from side condition Page 36 of 40 Wind . , Estimate of Trubolt Wedge Anchor 1/2 dia bolt with 4 1/8' embedment and 2 1/2 inch edge distance 2000 psi concrete rating 4000 psi concrete rating full load rating edge distance 65% rating edge distance 4660 lbf Ultimate 9640 lbf Ultimate 3 1/8 inch 1 9/16 inch Estimated rating for 3000 psi concrete = 7150 lbf ultimate Estimated edge margin reduction = 0.86 Bolt Load safety factor = 4 Allowable bolt load at 2.5 edge distance = 1537.25 lbf Allowable load for DTT2Z hold down = 1825 lbf in 1 1/2 DF stud w /8SDS screws Page 37 of 40 Estimate of seismic loads. Seismic Parameters Risk Category Seismic Importance Spectral Response Ss = S1 = Fa = Fv = Sms = Sm1 = Site Class Design Spectral acc parameters Sds = Sd 1 = Response Modification Factor Analysis Procedure Used Factor 1.501 0.518 1 1.5 1.501 0.777 Seismic Design Base Shear I or II Table 1.5 -1 ASCE -7 -10 1 Table 1.5 -2 ASCE -7 -10 USGS earthquake design maps USGS earthquake design maps USGS earthquake design maps USGS earthquake design maps ASCE 7 11.4.3 ASCE 7 11.4.3 D ASCE 7 11.4.2 1.000667 ASCE 7 11.4.4 0.518 ASCE 7 11.4.4 6.5 ASCE 7 Table 12.14 -1 item 13 simplified ASCE 7 12.14.8 V = F *Sds*W /R F= 1 Base Shear = Vertical distribution of Force Fx top of slab = Fx top of Wall = 3719.535 lbf Fx = WxNV*V 1287.15 lbf 974.4948 lbf Page 38 of 40 ASCE 7 12.14.8.1 Seismic Length of garage = 25.5 ft 12 12 Weight of Roof 6329.996 lbf Weight of Walls 2030.907 lbf Weight of building 8360.903 lbf Weight of Slab 15799.97 lbf Loads on attic ceiling diaphragm: Rh1 = 553.6902 lbf _® 9ft Rh2 = 420.8044lbf 16.5 ft 1 • 1 12.5 ft 6.25 ft 10ft 12.5 ft F = 974.4948 lbf Rvl = 691.0054 lbf Rvr : 691.0054 lbf Page 39 of 40 Seismic shear wall at Rh2 = 9.5 ft long lateral shear load peak = vertical shear load = Loads on rear shear wall: 50.44444 lbf/ft 27.09825 lbf/ft wt = 73.96021 lbf/ft Rvl = 905.2035 lbf 12.5 ft 1 F =� 553.6902 lbf I 10ft Rvr = - 19.2992 lbf lateral shear load = 44.29522 lbf/ft vertical shear load = 90.52035 lbf/ft Loads on interior shear wall: wt = 31.98279 lbf/ft Rvl = 594.8704 Ibf 9.5 ft 1 F = 420.8046 lbf 10ft Rvr = 291.0339 lbf lateral shear load = 44.29522 lbf/ft vertical shear load = 59.48704 lbf/ft Page 40 of 40 • city of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director November 14, 2011 Paul Vaughn 4531 S 137th St Tukwila, WA 98168 RE: Incomplete Letter #1 Development Permit Application D11 -364 Vaughn Carport — 4531 S 137 St Dear Mr. Vaughn, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 8, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Dave Larson at 206 431 -3678 if you have any questions regarding the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, , p ROJ-- v� Bill Rambo Permit Technician Enclosures File: D11 -364 W:\Permit Center \Incomplete Letters \20I1\D11 -364 Incomplete Ltr # 1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Determination of Completeness Memo Date: November 10, 2011 Project Name: Vaughn Carport Permit #: D11 -364 Plan Review: Dave Larson, Senior Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Please provide a foundation plan. 2. Please provide a typical cross - section specific to your project. I have included an example of one with this letter. Do not submit this example as it does not match your project. 3. The front opening of the garage will need lateral wall bracing panels. There is a generic code method of bracing this wall line that involves two 16 inch wing walls, one on each side of the opening. If you prefer to not add these brace walls a structural engineer would be needed to evaluate the lateral bracing system. I am also enclosing a copy of the generic brace walls for your review. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • • R602.10.3.3 Method PFH: Portal frame with hold- downs. Method PFH braced wall panels constructed in accordance with one of the following provisions are also permitted to replace each 4 feet (1219 mm) of braced wall panel as required by Section R602.10.3 for use adjacent to a window or door opening with a full - length header: 1. Each panel shall be fabricated in accordance with Figure R602.10.3.3. The wood structural panel sheathing shall extend up over the solid sawn or glued - laminated header and shall be nailed in accordance with Figure R602.10.3.3. A spacer, if used with a built -up header, shall be placed on the side of the built -up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full - length outer studs of each panel. One anchor bolt not less than 5/8inch- diameter (16 mm) and installed in accordance with Section R403.1.6 shall be provided in the center of each sill plate. The hold -down devices shall be an embedded -strap type, installed in accordance with the manufacturer's recommendations. The panels shall be supported directly on a foundation which is continuous across the entire length of the braced wall line. The foundation shall be reinforced as shown on Figure R602.10.3.2. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line. 2. In the first story of two -story buildings, each wall panel shall be braced in accordance with item 1 above, except that each panel shall have a length of not less than 24 inches (610 mm). EXTENT OF HEADER DOUBLE PORTAL FRAME (TWO BRACED WALL PANELS) EXTENT OF HEADER SINGLE PORTAL FRAME (ONE BRACED WALL PANEL) MAX HEIGHT 10' 6' TO IS' FASTEN TOP PLATE TO HEADER WITH TWO ROWS OF 16D SINKER NAILS AT 3' O.C. TYP. 1000 LB STRAP OPPOSITE SHEATHING FASTEN SHEATHING TO HEADER WITH RD COMMON OR GALVANIZED BOX NAILS IN 3" GRID PATTERN AS SHOWN AND 3' O.C. INALL FRAMING (STUDS, BLOCKING, AND SILLS) TYP ION.WiDTH = 16' FOR ONE STORY STRUCTURE MN. WIDTH = 24' FOR USE IN THE FIRST OF TWO STORY STRUCTURES MIN_ 2x4 FRAMING 3®' M1N_ THICIWESS WOOD STRUCTURAL PANEL SHEATHING MN. DOUBLE 2x4 POST MN. 4200 LB 71E-DOWN DEVICE (EMBEDDED INTO CONO2ETE AND NAILED INTO FRAMING) SEE SECTION R602.10.3.3 itt4 For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound force = 4.448 N. TYPICAL PORTAL FRAME CONSTRUCTION FOR A PANEL SPIJCE (IF NEITf), PANEL EDGES SHALL BE BLOCKED, AND OCCUR WITHIN 24' OF MID- HEIGHT. ONE ROW OF TYP. SHEATHING -TO- FRAMING NAILING 18 REQUIRED. IF 2x4 BLOCKING IS USED, THE 2x4'S MUST BE NAILED TOGETHER WITH 9 160 SINKERS FIGURE R602.10.3.3 METHOD PFH: PORTAL FRAME WITH HOLD -DOWNS MIN. 1000 LB TIE DOWN DEVICE ERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -364 DATE: 01/13/12 PROJECT NAME: VAUGHN CARPORT SITE ADDRESS: 4561 S 137 ST Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building ivision Fire Prevention Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 01/17/12 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire El Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 02/14/12 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 "EMIT COORD COPY, PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -364 PROJECT NAME: VAUGHN CARPORT DATE: 11/08/11 SITE ADDRESS: 4531 S 137 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPA TMEI�TS: ( MA AM I b.-- Ong Building Division Public WNW— � Structural Fire Prevention Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 11/10/11 Not Applicable Comments: Permit Center Use Only J� INCOMPLETE LETTER MAILED: 11 • 1-Lt LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg- Fire ❑ Ping ❑ PW ❑ Staff Initials: V�P� TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 12/08/11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • "ti City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIVED CriVornstwu IJAN 11.3 10121 Main' Com Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: t l 1- 312v1�- Plan ChecWPermit Number: D 11-364 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Vaughn Carport Project Address: �4561 S 137 St Contact Person: � c.L. \ '1 cou+-) Summary3f Revision: O uL�_ Phone Number: 7-0 Cr 3gq-1"19.6Q1- 1' C7 tti - O +Q Lo t I S uCG.< 02k,.., I r to>� Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: A dEntered in Permits Plus on ,5d-s 5 \applications \forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -3670 FAX (206) 431 -3665 E -mail: tukplan@ ci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433-0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) RA-ta \k.A cIn [please print name] , states as follows: PERMIT NO: t 1 I v 63/4 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction work. RC‘,A V `n+J Owner /Owner's Agent Signed and sworn to before me this day of ' /Z ,20// . • .14\ NOTARY PUBLIC in and or the State of Washington Residing at Name as commissioned: My commission expires: , County ��/Lah4,14- 18.27.090 Exemptions. The region provisions of this chapter do not apply to. 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; ii. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a certified residential specialty electrician, or an electrical trainee meetiffhe , requirements of chapter 19.28 RCW to erforni plumbing work that is incidentally, directly, an immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power'and limited waste and /or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions.