Loading...
HomeMy WebLinkAboutPermit D11-379 - SHIPPERS TRANSPORT EXPRESS - TRAILER AND ADA RAMPSHIPPERS TRANSPORT 10180 WEST MARGINAL WY S EXPIRED 07 -31 -12 Di 1-379 City (A/Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 0423049073 Address: 10180 WEST MARGINAL PL S TUKW Suite No: Project Name: SHIPPERS TRANSPORT EXPRESS Permit Number: D11 -379 Issue Date: 01/03/2012 Permit Expires On: 07/01/2012 Owner: Name: MELLON DESIMONE Address: C/O BNY MELLON NA , 1201 3RD AVE #5010 98101 Contact Person: Name: ROGER STARKWEATHER Address: 5511 SW HANFORD ST , SEATTLE WA 98116 Phone: 206 306 -5541 Contractor: Name: OWNER AFFIDAVIT - ROGER STARKWEATHER Phone: Address: Contractor License No: Expiration Date: DESCRIPTION OF WORK: TRANSPORT AND SET UP ONE 480 SF L&I OFFICE TRAILER. CONSTRUCT ADA ACCESS RAMP. PROJECT ON VALLEY VIEW SEWER AND TUKWILA WATER. SEPARATE PERMIT REQUIRED FOR UTILITY HOOK -UPS. Value of Construction: $59,936.00 Fees Collected: $4,769.04 Type of Fire Protection: SMOKE DETECTORS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 8 Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11-379 Printed: 01 -03 -2012 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit construction or ; p - rfo to this pe Signature: N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: es not p e of work. Public: Non - Profit: N Public: Date: 0(1(021r2-- ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this development permit and agree to the conditions attached Date: t Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila doc: IBC -7/10 D11 -379 Printed: 01 -03 -2012 Building Department (206- 431 - 3670). • 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ** *FIRE DEPARTMENT CONDITIONS * ** 11: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. 13: Local U.L. central station supervision is required. (City Ordinance #2051) 14: Maintain square foot coverage of detectors per manufacturer's specifications in all areas including: closets, elevator shafts, top of stairwells, etc. (NFPA 72- 5.5.2.1) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 17: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 18: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 23: For all commercial, multifamily and single family subdivisions, hydrants shall be placed so that a hydrant is within 150 feet of a building and so that no point of a building (around its perimeter) is greater than 300 feet from a hydrant. Distance from a hydrant to a building is measured along the path of vehicular travel. (City Ordinance #2052) 24: All required hydrants and surface access roads shall be installed and made serviceable prior to and during the time of construction. (IFC 503.1, 508.1) 25: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the doc: IBC -7/10 D11 -379 Printed: 01 -03 -2012 International Building Code shall not requirear t grasping, tight pinching or twisting of the,t to operate. (IFC 1008.1.8.1) 27: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 28: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 29: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 30: Any overlooked hazardous condition and /or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 31: ** *PUBLIC WORKS DEPARTMENT CONDITIONS * ** 32: Any material spilled onto any street shall be cleaned up immediately. 33: Prior to moving the building on -site, a copy of the WSDOT moving permit, route map and proposed moving schedule shall be submitted to the City Development /Permits Engineer for validation. NO MOVING ACTIVITY SHALL BE COMMENCED UNTIL THIS VALIDATION HAS BEEN FORMALLY RECEIVED OR THE MOVER HAS CONTACTED THE DEVELOPER/PERMITS ENGINEER AT (206)433 -0179 TO VERIFY THE SAME. If a WSDOT permit has not been approved for the move, the City OVERSIZED LOAD MOVING permit will need to be applied for. 34: Applicant is proceeding at his own risk,since utilities hook -up permits has not been applied for. Poject is within Valley View Sewer District service area and Tukwila provides water service. 35: Office shall not be occupied untill building is hooked up to water and sewer. 36: Public Works fianal shall not be given until a separate permit is obtained for utility connections and water and sewer services are in place and running. 37: Traffic Concurrency Certificate Application shall be submitted with $1800.00 fee before building can be occupied doc: IBC -7/10 D11-379 Printed: 01 -03 -2012 CITY OF TUKi,A Community Develops,. Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: 3 t �C7yC Q 7 Site Address: 10 I $O \sloe r M &r of mai - 0Lrk Q`hL (AS Suite Number: Floor: Tenant Name: S p e c E,tpc6, New Tenant: ❑ Yes ❑.. No Name: YrlN Farr E_xpr6ss Address: ` ��,., ( 050 FcL�r qrr innl lA1c ( 5otrtil City: e)esittie, Stat i 1 Lip:(1 10 e. it Name: % No9c, r i ckf-k t-i4,rc. r Address: n5 il 50 N `mot' i.+rui 11 i 1"6' r City: C State: Zip:acAi 1 el Phone: ,)(4,6/ c•54-1 1 Fax: �P Email: roa()r-. --resrIG.ItriAm& [iva.rL, Company Name; Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: HA Applications On Line \2011 Applications Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: E .: Company Name: Engineer Name: City: Phone: Email: State: Zip: Fax: Page 1 of 4 ` B�DIN��P�REIt;T,�I - �iSaVt+1 3 K. +1t n +. '••- °1nl{%7.rLix :n .r- d:'!'� i -1K L s • Valuation of Project (contractor's bid priiP $ r� v Existing ding Valuation: $ Describe the scope of work (please provide detailed information): 4%VfAk 4 at --h� - 'Bela( kvA (24j 910 51" (hit?' (t) Will there be new rack storage? ❑ .... Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Butlding reasiin? quare Foo +'ir r. ' Y r ��r °" u'S+ ;xC '� d�'r�r - :�.3r.•'� %+&' `"L�" ¢ r,�'c» . l fa : NRiY .'�s�SA;$'L:. y�:'�"?���} ¢ "..i - 14�Y. `kt...Pk Y^. „vrw't J 4 t P$�' . C it 5 .rs: 1 xx i+ " al, 'krt.�,: i t :.(� � t �Y_ � °�....C1�r :1 � �g'r'z � .. � .'! �h ..M?a.T%' `' .': ei ,,_a . ;= Existing t ,� -4R' ..�+•-� y> 'p'�,? ye ?�i: < 7 t a�n��F y�� � gx� k?j ( p9 N'}�•'t� }d"'s� ki:r_ ' 3,.A 4.a 'FT?•S'T Y�i q�s'f: Q 3nterioril einc. e ; .. ,tom _'^..crk r•,,"Addrtign #� r �{y��j"�1 ,��'`'V�1 �^�µ���` `yqi, .�.5�a'4� ,..Y,""jY_ i., Existrng Y ni..,�,�. a �•9a�.. ; s x Structure_ +a ,J.."'r`tizr ..5. Eta S F"f � +si.�,fa r t ' G SK'e: i^i 4.. �ST� l,�sS 1V y ..i , i. '"i. "'"rth r ty . NeW .� . .;, .+y- ,}= a`S"�r. . -f' '�z { ,.-, 4i',,,. S' k' �.�N:..��'.W4"a l./��sY� c?f�.E onsiruction her fir., t s'S r�"r_ , x € IDC:t ,? ; t ..e i`i � as Type of ,� /�.��.....� o.. .12'... -..'� t •VL upancy er `'.'I'J p IBC st :Floor tx aFy� itF iY tJ �"."�d%- '- ±T.3:FL6>iti T• X5}'1 -vlT.'Cit,. Si ^k FIder. , i { mtS {:7i s.,,,i ;i ::15:x? Floors 5 sthru� < 1` 4Basem�_pt SC Ffati /l`t ,,if •Accessory 'r1 .` •' ...':,4 -s' F- A P F Attached} Garage tachedtC,arage Attached Carpoit�L+" '�';i.i`" .3o a^HDCt„ i _t, pctrl '� t sa x t- f :fit' E ..�44; ?.. 1{s�`_b....'•�`:+RSt is Covered?DeckT ^ a Untova ered`Deck�k Ct°�I PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes] No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: i` ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None Other (specify)E -_S Will there be storage or use of flammable, combustible or hazardous materials in the building ? / ❑ Yes No If "yes', attach list of materials and storage locations on a separate 8 -1 /2" x 11 " paper including quantities and Material Saf ty Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System – For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms- Applications On Line\2011 Applications\Permit Application Revised - 8- 9.11.docx Revised: August 2011 bh Page 2 of 4 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin - #1 far fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate 0... Highline ❑...Valley View ❑...Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance 0... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right -of -way Use - Nonprofit for less than 72 hours ❑ .. Right -of -way Use - No Disturbance ❑ .. Construction/Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards 0... Geotechnical Report 0... Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) 0... Right-of-way Use - Profit for less than 72 hours 0... Right-of-way Use — Potential Disturbance 0... Work in Flood Zone 0... Storm Drainage ❑ .. Sanitary Side Sewer 0... Abandon Septic Tank 0... Grease Interceptor ❑ .. Cap or Remove Utilities 0... Curb Cut 0... Channelization ❑ .. Frontage Improvements 0... Pavement Cut 0... Trench Excavation ❑ .. Traffic Control 0... Looped Fire Line 0... Utility Undergrounding ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size ... WO # ❑ .. Temporary Water Meter Size .. WO # ❑ .. Water Only Meter Size WO # ❑ ...Deduct Water Meter Size ❑ .. Sewer Main Extension Public ❑ Private ❑ ❑ .. Water Main Extension Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms- Applications On Line \2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh Page 3 of 4 r Value of Construction — In all cases, a value construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 'I W ', .30_' UT S' IZED AGENT: Signature: Print Name: Mailing Address: G,rj 1-11 1- ' -O Date: ° L.I1 5bl ( Day Telephone: 26(1 3o40 City H:1Applications\Forms- Applications On Line12011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 2011 bh ft(f L State Zip Page 4 of 4 of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R12 -00008 Initials: JEM Payment Date: 01/03/2012 User ID: 1165 Total Payment: 5,879.78 Payee: SHIPPERS TRANSPORT EXPRESS, INC. SET ID: 0103 SET NAME: SHIPPERS TRANSPORT EXPRESS SET TRANSACTIONS: Set Member Amount C12 -001 1,800.00 D11 -379 4,079.78 TOTAL: 1,800.00 TRANSACTION LIST: Type Method Description Amount Payment Check 2567546 5,879.78 TOTAL: 5,879.78 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES FIRE IMPACT FEES PARK IMPACT FEES STATE BUILDING SURCHARGE TRAFFIC CONCURRENCY TRAFFIC MITIGATION FEES 000.322.100 90830402.5000.53 90330109.5000.53 640.237.114 104.367.121.00 104.367.120 TOTAL: 1,060.40 779.52 401.76 4.50 1,800.00 1,833.60 5,879.78 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0423049073 Permit Number: D11 -379 Address: 10180 WEST MARGINAL PL S TURN/ Status: PENDING Suite No: Applied Date: 11/30/2011 Applicant: SHIPPERS TRANSPORT EXPRESS Issue Date: Receipt No.: R11 -02591 Initials: User ID: JEM 1165 Payment Amount: $689.26 Payment Date: 11/30/2011 02:00 PM Balance: $1,064.90 Payee: SHIPPERS TRANSPORT EXPRESS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2561728 689.26 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 689.26 Total: $689.26 doc: Receiot -06 Printed: 11 -30 -2011 INSPECTION NO. INSPECTION RECORD Retain a copy with permit D 11-3(71 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proieict: .� GN p et5 1 f fpl d i i Type o Inspection: ' r Nt. , Ne, r Address: Date Called: L) Cam-_ ._ Special Instructions: ,&* 4-....1 i J [/I l r Date Wante . -31 _ r . /a.mm Requester: Phone No: '2..A6-"713 -1251 Approved per applicable codes. a Corrections required prior to approval. COMMENTS: A ,h4 Alp /0 V•- r O V-- s 13 p e — L) Cam-_ ._ 1) Y "-.. V c./ f( `r j. (d . 1 ,&* 4-....1 i J [/I l r 4 e liCr - . 4 1Inspector: ,Date: 1-. 3� i REINSPECTION FEE REQUIRED.. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0: PERMIT N0. AA CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v., (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj c . . ` 7 s . , AAd if 0 }eves Type of nspection Address:. .et �' / i0 { . N v . r r/ % % A/4 (e�Ap 4 Date Called: �.0 L, ,s 1 `�ny�• --r�� ..- 604 1 /r" ". Special Instructions: Date Wanted:. 1Z-24( /'a.m. I— (j " / p.m. Requester: '1— Phone No: - 7 f q,, C 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: V t.,3e1U--- ou0 A-6 A (Ez?,),reAitei . - . -A k-c t, u ; re M e. s -FI . A: Ail bf- (LA) (,U &JrA 1 � . S r AAA.: nO -e. s r 64 /P. f. oe_ `i F' ..-- - .. ,, t A l Inspec or: Date: ' + z___ REINSFECTION FEE REQUIRED. Prior t next inspection. fee must be paid at 000 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 06 -01 -2012 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director ROGER STARKWEATHER 5511 SW HANFORD ST SEATTLE WA 98116 RE: Permit No. D11 -379 SHIPPERS TRANSPORT EXPRESS 10180 WEST MARGINAL PL S TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 07/31/2012. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 07/31/2012, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, ifer Marshall it Technician File: Permit File No. D11 -379 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206 -431 -3670 • Fax 206-431 -3665 4' 1 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 2, 2011 Roger Starkweather 5511 SW Hanford Street Seattle, WA 98116 RE: Incomplete Letter #1 Development Permit Application D11 -379 Shippers Transport Express —10180 West Marginal PI S Dear Mr. Starkweather, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on November 30, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433 -7163 if you have any questions regarding the attached comments. Public Works Department: Joanna Spencer at 206 431 -2440 if you have any questions regarding the attached comments Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Jenn fer,Ma Pe it -ch shall ician Enclosures File: D11 -379 W:\Permit CenterkIncomplete Letters \2011\D11 -379 Incomplete Ltr #I.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Allen !Johannessen, Plan Examiner Determination of Completeness Memo Date: December 1, 2011 Project Name: Shippers Transport Express Permit #: D11 -379 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The site plan submitted does not accurately match the GIS map in proportion. Provide an accurate site map with the information showing where this trailer shall sit and any other buildings on the lot. Provide dimensions to show the trailer setback distance from the property line. 2. The address indicated on the plan does not match the address provided on the permit application. Show the correct address for this lot for this permit. 3. The ADA bathroom does not meet accessibility. No other fixtures or obstructions shall be within the required water closet clearance. A clearance around a water closet 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall, shall be provided. Provide dimensions for the bathroom. Show the clearance around the water closet per code. Show grab bars with the specifications and dimensions for grab bars around the water closet. (2003 ANSI 604.3, 604.3.2 & 604.5.1) 4. Provide specific details for the ADA ramp. Specify all materials and fasteners. Show all dimensions and slope of the ramp including width and ramp landing per ADA code. 5. Identify type tie downs for the trailer and provide manufactures specifications and instructions for the tie downs. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PUBLIC WORKS DEPARTMENT COMMENTS DATE: December 2, 2011 PROJECT: Shippers Transport Express PERMIT NO: D11 -379 PLAN REVIEWER: Contact Joanna Spencer (206) 431 -2440 if you have any questions regarding the following comments. 1) Plan showing utility hook -ups was not submitted. a) Sewer service is provided by Valley View Sewer District, 3460 South 148th Street, Suite 100,Tukwila, WA 98168, phone number (206)242 -3236. Applicant shall submit a SEWER Availability Letter from the District, see attached form and obtain a sanitary sewer permit from the District. b) Show location of the existing water meter. c) Per Mike Cusick, Public Works Senior Water Engineer @ 206 431 -2441 each building shall be metered separately. This means that the proposed building shall have a separate water tap off the main, separate water meter and a Reduced pressure Principle Assembly (RPPA) immediately downstream of the new WM. See PW Bulletin A -1 for water meter fee schedule. d) Provide construction cost for water service to the proposed building, see attached Bulletin A1,2. 2) Submit Traffic Concurrency Certificate Application and pay $1,800.00 fee to Public Works. Project is subject to Transportation Impact fee in the amount of $3.82 per square foot of gross floor area. 3) Before building can be transported to the site the applicant shall submit a copy of the WSDOT oversized load permit to Public Works for validation together with move schedule and hauling route map within Tukwila city limits. If there is no WSDOT permit an oversized load move permit shall be obtained from Public Works. W:Other /Joanna /D11 -379 inc • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -379 DATE: 11/30/11 PROJECT NAME: SHIPPERS TRANSPORT EXPRESS SITE ADDRESS: 10180 WEST MARGINAL PL S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPA TMEN S: 'I Bui i(ng Division 1 l(k1 ,d2 -`■ u is Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete DUE DATE: 12 /01 /11 Incomplete ij Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 11— O 7 1I LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW Staff Initials:.) A& TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/29/11 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 WERINIT COORD COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -379 DATE: 12/12/11 PROJECT NAME: SHIPPERS TRANSPORT EXPRESS SITE ADDRESS: 10180 WEST MARGINAL PL S Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # after Permit Issued DEPARTMENTS: Auc 16-41 Bui ding Division Public orks PW iW 1)--)-0141 Planning Division Fire Prevention Structural Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 12/13/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 01/10/12 Not Approved (attach comments) ri DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through: the mail, fax, etc. Date: OtAxii Plan Check/Permit Number: D11-379 Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued C�b�ATtN LA ❑ Revision requested by a City Building Inspector or Plans Examiner DEC 1 2 2011 PEBMn - CENTER Project Name: Shippers Transport Express Project Address: 10180 West Marginal P1 S Contact Person:YD4fAt Phone Number: Z (e 3bCe Summary of Revision: , � Pa Pr VaA7y 6Usfa 4 to pevRie Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: b' Entered in Permits Plus on 1211 Z( it C 'ff,tact-t--bP A - key 01 1414cl 1zMiew- 1-v5>4 GALte,01 �eqil61'CiY; \applications \forms - applications on line\revision submittal Created: 8 -13 -2004 Revised: CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431 -367o FAX (206) 431 -3665 E -mail: tukplanaci.tukwila.wa.us Permit Center /Building Division 206 431 -3670 Public Works Department 206 433-0179 Planning Division 206 431 -3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) G .i1-c4 , states as follows: [please print name] PERMIT NO: —?j1 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requireme t of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 1 , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that . t oth have under state law in any decision to engage an unregistered contractor to perform cons Owner /Owner's Signed and sworn to before me this day of vL4-11 £-CCt KJ_ , 201 . N ARY PUBLIC in and for the State of Washington Residing at / G] , County Name as commissioned: 71-6(/64-_ My commission expires: 05-d-P 61 18.27.090 Exemptions. The regis Lion provisions of this chapter do not apply 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of factures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile /manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; c-d An owner* who performs maintenance, repair, and eration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile /manufactured home dealer or manufacturer who subcontracts the installation, set -up, or repair work to actively registered contractors. This exemption only applies to the installation, set -up, or repair of the mobile /manufactured homes that were manufactured or sold by the mobile /manufactured home dealer or manufacturer, 18. An entity who holds' a valktelectrical contractor's license under chapter'; }?c�`.28 RCV1 employs a certified journeyman elect rl ; ;'�a•cer ified deiitial specialty electrician, or an el ' ` ` ` ectiacal trainee meatinithe requirements of chap i 19.28 RCW to`perr corm plumbing work that is incidentally, directly, and icriediately appropriate to th likk+in -kind replaccine4t of a household appliance or otherignaWhousehOld,utilitiition equipment that requires limited*cfctic.powtif and4imited waste and /or water connection fir' i ctziciil trainee must be supervised by a certified electridan while performing plumbing work. • Per Washington State Department of Labor and Industries, lessee has been interpreted to be equivalent to owner for the purpose of these exemptions. Parcel # 0423049001 4P/4 Ca)4U4, amp( acce,, ,/0 r*_jO o' ,b41 l/p4tµ A 100 IL nci surfac€ shall bP ha. rot sKvfac aspAa,rte co cede or s1,K1'10qhr, ra• llc,l„ -' doer na .^ 05, l Y1p t.(601-t. /aD /4 ar bot * =J 680 t y r C N a bay ,y'ar ctp /q rvµfr•ve Water Meter PLANNING APPROVED No changes can be made to these plans without approval from the Planning Division of DCD Approved By: v Proposed New Office Building Existing Office Building Parcel # 0423049073 30' Gated Entrance 380' w Marginal pi s. Legal Description Parcel 042304 -9073 POR N 512.5 FT OF NW'/ OF SE 14 LY SWLY OF NELY BDRY LN OF PROPOSED EXT OF DUWAMISH WATERWAY WCH IS 225 FT NELY MEAS AT R/A FR SELY PROJ OF C/L OF CWW & LY NELY LN PRIMARY ST HWY NO 1 LESS POR SELY OF SOUTH MGN OF 60 FT STRIP UNDER AUD FILE NO 4759860 DESC AS LY APPROX 600 FT SELY OF CENTER COR OF section 4 & BEARING SOUTH 48 -08 -16 W TGW POR GL 5 LY NELY & SELY OF PRIMARY ST HWY NO1 Project Notes: 1. Transportation of office trailer by others & are to procure necessary permits 2. Specific to water & electricity - GC /owner is responsible for obtaining necessary permits REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. WM.: s {'' T : Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED Gliethanicat Cr�1 erkumbIng Comas plpfng C:17 of Tukwila Bi., `NG DIVISION FILE COPY Perri* No.?7't1 pn review approval is field to error, a 1 neiselons. A : :;. =v at of construction documents dog rc; uthorize III \-:olaton of any /adopted code or ord ntc -,. Receipt 01 Ti- Fr 1) Copy � conditions Ls a il/maior ed: By /4:4 City Of Tukwila BUILDING DIVISION ee\. r 10-C\ Ex D JUL 3 1 2012 ed entrance * * Landscaping - add six "Emerald Green" Arborvitae Property Line Fence North Scale: 1" = 60' SITE PLAN Project Directory Project Name: Shippers Transport Express Project Address: 10180 W marginal Place S Tukwila, WA 98168 Property Owner: Shippers Transport Express Scope of Work: Set One (1) 12' x 40' (480 square feet) Factory Assembled Building. Use: Office Trailer. ADA ramp to be site built. L& I approved Building Gold Seal Number - F623- 009 -000 at, REVIEWED FOR DE COMPLIANCE APPROVED DEC 2 3 2011 Clay of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW ILA Uk 22011 PERMIT CENTER INCOMPLETE LTR V\ 11-20-2011 N cD N 0 a) co .; E 0 D hi.•ers rans•ort Expres 0180 West Marsinal Place out ukwila WA 9816; rawn by: Ro. er Starkweather, reative pace Typical Set / Tie down End View General notes: Building Design Loads as follow: - roof 30 P.S.F. - Wind90 M.P.H. Exposure B - Floor50 P.S.F. Or 2000 Ibs - Seismic...Zone D BLOCKING & TIE DOWN DETAILS TYPICAL TIE -DOWN ANCHORS SHALL BE ATTACHED TO BEAM FRAME USING CERTIFIED GALVANIZED STRAPPING PROVIDED BY TIE -DOWN MANUFACTURER BEAM WEDGES PIER BLOCKS 8x13 16 HOLLOW CONCRETE IIIEIII III =III =IIIE EIII III =III -III- ANCHORS AT 60 DEGREES +/- ANGLE. N 40' Elevation View JUL 31 2012 4 x 18.4' ramp in w/ p -* I Plan View 5' x 5' landing 5' x 5' landing Tuie Down Strap Specs: TJT Idaho, Chehalis, WA 12" Strap w/ buckle & 30" approved Anchors Straps: min 1.25" wide x .035 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 3 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OW 12 2011 PERMIT CENTER u_ 11-20-2011 co 0 Revised: 12 -10 -2011 . hi • •ers ransport xpres 0180 West Mar• inal P ace out LTIMSIara Brawn b : Ro s er Starkweather, reative pace 1995 Commercial Trailer has been approved and permitted through L &I Serial number affixed to office trailer Scale = 3/16 = 1' -0" I I I MHA Vinyl or metal skirting around perimeter of buildings. Complies with IBC Sec 2304.11.2.6 co 12x 12 office Bathroom 8' x 5.75' Hallway 12x 12 office Grade Access Panel to be installed with a minimum access opening of 18 x 24" ADA Ramp construction to be aluminum, pre - made modular sections: Manufacturer is Disability Systems (or equivalent) www.disabilitysystems.com 1:12 Ramp 4x18.4" rampinw/ 5' x 5.6" landing. Positioned 18" from existing windows JUL 31 2012 Typical ADA Sections CURB ThEVATION VERTICAL RAIL Handrails shall be: 1. Required at slopes > 1:20 2. Cin each side d ramp. 3. Continuous the full length of ramp. 4. NOT required at Curb Ramps. Ramp Width: 1. Determined by occupant load [O.L.) served, min. 44 ". 2. May be min. 36" wide when O.L. is less than or equal to 49. 3. Handrails may project 3.5" into required width on each side. 4. Other projections: Max. 1.5" into required width. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 3 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 122011 PERMIT CENTER O N O N LL 0 O N O 0 0) tea) I..L Ed iej pi4 gain 11:1 0 a) U (6 0 (6 00 00 co (3) 2 Q (1) a) CO CD •� Q l- rawn b : Ro • er Starkweather, reative pace