Loading...
HomeMy WebLinkAboutPermit D11-389 - DITCHWITCH NORTHWEST - STORAGE RACKSDITCHWITCH NW 12900 48 AV S Di 1-389 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0004800005 Address: 12900 48 AV S TUKW Suite No: Project Name: DITCHWITCH NW DEVELOPMENT PERMIT Permit Number: D11 -389 Issue Date: 12/21/2011 Permit Expires On: 06/18/2012 Owner: Name: STRANDER FAMILY L L C II Address: PO BOX 88636 , TUKWILA WA 98138 Contact Person: Name: ROGER STUESSI Address: 9883 40 AV S , SEATTLE WA 98118 Contractor: Name: ENGINEERED PRODUCTS Address: 18271 ANDOVER PK W , TUKWILA WA 98188 Contractor License No: ENGINPC931C0 Phone: 206 394 -3331 Phone: 206 - 394 -3300 Expiration Date: 02/20/2013 DESCRIPTION OF WORK: INSTALL 4 SECTIONS OF PALLET STORAGE RACKS AND 20 SECTIONS OF SMALL PANTS SEINING. Value of Construction: $0.00 Fees Collected: $369.97 Type of Fire Protection: International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: Electrical Service Provided by: SEATTLE CITY LIGHT * *continued on next page ** doc: IBC -7/10 D11 -389 Printed: 12 -21 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: N Number: 0 Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: JA Date: 1 hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: 4��-/� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. doc: IBC -7/10 D11 -389 Printed: 12 -21 -2011 6: All rack storage requires a separate per sued through the City of Tukwila Permit C Rack storage over 8 -feet in height shall be anchored or braced to pr overturning or displacement during seis ents. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: Clearance between ignition sources, such as light fixtures, heaters and flame- producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 12: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 13: Storage shall be maintained 2 feet or more below the ceiling in nonsprinldered areas of buildings or a minimum of 18 inches below sprinlder head deflectors in sprinldered areas of buildings. (IFC 315.2.1) 14: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 19: Maintain fire extinguisher coverage throughout. 20: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 21: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. doc: IBC -7/10 D11 -389 Printed: 12 -21 -2011 24: These plans were reviewed by Inspect° 1. If you have any questions, please call Tuft Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -389 Printed: 12 -21 -2011 CITY OF TUKW1 Community Developm,..g Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: / /www.TukwilaWA.gov CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: /c?” ? 0-Z.) V (r /Q✓e -- -s Tenant Name: #0/ -11, t 1-ti a r<-- 4 /V • LA/ ' City: 1?0 Illy �1n j h State: 1 r Zip: tt'l4 -. ., .. Company Name: �% JJ rf 1,7ie ‹ -i-e- i r7 g---o GGce .e4 _s .l lei Name: , et c'...,,,_ .S7 `t `SS / Contr Reg No.rAi , /7 Exp Date: Address: Architect Name: City: (---e. 7„7-6 State:14,4 Zip:l f..//r- Phone: 2.6 6 „,.71.,_e, _ 13 .3/ Fax: R �.. ,, y___6.,,, 3 7 Email: / ..0 c/ _ City: 1-1 Wpplicationaorms- Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 docx Revised. August 2011 bh King Co Assessor's Tax No.: (VL11)0 Suite Number: Floor: New Tenant: J] Yes ❑.. No � Company Name: �% JJ rf 1,7ie ‹ -i-e- i r7 g---o GGce .e4 _s .l lei Address: City: ‹ States, Zip? f / /l- Phone,?-i 6 3 ?i/ -3'31 Fax:266.36F--d Y37 Contr Reg No.rAi , /7 Exp Date: Tukwila Business License No.: iv, — 0 i or)"\ oo 1-1 Wpplicationaorms- Applications On Line \2011 Applications\Permit Application Revised - 8-9-11 docx Revised. August 2011 bh King Co Assessor's Tax No.: (VL11)0 Suite Number: Floor: New Tenant: J] Yes ❑.. No � Engineer Name: R f City: „a, //� ,�71 State:, Zip:S i% el ; Company Name: ...---"' Architect Name: Address: City: State: Zip: Phone: Fax: Email: Company Name: 'eh Engineer Name: R Address /ear_ 6-4„,, e ,yz,,y in (id City: „a, //� ,�71 State:, Zip:S i% el ; Phone:, 6 , a5- _ 3 d 7. Fax: Email: 4cN /Lie &,,L c /h,T- nor Page 1 of 4 Valuation of Project (contractor's bid p Existingauilding Valuation: $ Describe the scope of work (please provide detailed information): /n fro /l p // ,sro■s-.Q /c /tea c 4-5 <y Sew ‘• ) d-- .5-",41, R.L i..r s e-G viri�C Will there be new rack storage? ....Yes ❑ ..No If yes, a separate permit and plan submittal will be required. Budding A reasnSquare Eoo "VA.3,3tit 11241:44 2 .. , n. g-4•} x ;v 4 - s�' * S.`{.t. " * is. ,�, ucg- o rt'"fis q l�' "•,s rF�'. - f..,kc n #erioriRem odel ... .: - :, ' .., k atrAddtt>on to ..�`,7�»;r trr cue, ... .4r §.s• '$i ^. ew - aw> �T of, -; onst'z r uc t io� nz�t } r , . •�a;pr � l B .. e of,$; f . r u .] 7� C? ,e Ke� r ixst St y5"(f-S-7 fo J)-/ ,w V/ �i e� / s rip)) �T'�:y:�x,a�.�..°.�`��t�.:Y f�t, s`.4�= .:�i�r�•.cr:� 3w.,u F1.00r33.` -!'zr. S lS i�' d wi asement iirl rls Accessorq #Structure Attached Crage "'' Detached Garage �" y Detached Carport' V.t..- . �±4.i�.:i2� itn:r.�v.::.a 5:3i:f ^w Coverel ecl _ { Uncovered gir �' PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) kFor an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers Or Automatic Fire Alarm None ❑ Other (specify) ❑ Yes No Will there be storage or use of flammable, combustible or hazardous materials in the building? If 'Yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:lApplicationslForms- Applications On Line12011 Applications\Permit Application Revised - 8- 9- 11.docx Revised: August 201 1 bh Page 2 of 4 Value of Construction — In all cases, a valuWconstruction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: AUTHORIZED G, T: �� Print Name: ,y e si t-c 05,3" Mailing Address: 991-f 3 '/ 6 Ave-- Sr Date: / ? /// Day Telephone: ? g 3 - 3 3 3/ v H:Wpplications\Forms- Applications On Line\2011 Applications\Permit Application Revised - 8- 9- 11.docx Revised- August 2011 bh City State Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0004800005 Address: 12900 48 AV S TUKW Suite No: Applicant: DITCHWITCH NW RECEIPT Permit Number: D11 -389 Status: APPROVED Applied Date: 12/07/2011 Issue Date: Receipt No.: R11 -02770 Initials: User ID: Payee: WER 1655 Payment Amount: $226.00 Payment Date: 12/21/2011 03:39 PM Balance: $0.00 ROGER STUESSI TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 123681 ACCOUNT ITEM LIST: Description 226.00 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 221.50 640.237.114 4.50 Total: $226.00 doc: Receipt -06 Printed: 12 -21 -2011 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.Rov Parcel No.: 0004800005 Address: 12900 48 AV S TUKW Suite No: Applicant: DITCHWITCH NW RECEIPT Permit Number: D11 -389 Status: PENDING Applied Date: 12/07/2011 Issue Date: Receipt No.: R11 -02660 Payment Amount: $143.97 Initials: JEM Payment Date: 12/07/2011 03:36 PM User ID: 1165 Balance: $226.00 Payee: ROGER H STUESSI TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 153553 ACCOUNT ITEM LIST: Description 143.97 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 143.97 Total: $143.97 doc: Receiot -06 Printed: 12 -07 -2011 1' t' • INSPECTION RECORD Retain a copy with permit DI( -31 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of I Address: I t 447 Date Called: Special Instructions: Date Wanted:. 1 Z -2 5---- // gym.' p.m. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: /2-' T Lu'r AA tit tA Inspector. 1Date:1 Z S l I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. a• -4t- INSPECTION' NO. INSPECTION RECORD Retain a copy with permit -Olt -3 61 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Projects 1- n,‘ 1 Type of Inspection: Address: 24 00 4f Auk_ Qc I 'OAS Date Called: Date Wanted:. l --ZS— t, a m P.m. ,1 Special InstructiiCons: R A (As ' A S 70 See, '(L4"(S Requester: Phone No: 9.40G,' 3q4 - 333 I Approved per applicable codes. El Corrections required prior to approval. COMMENTS: t) OP-0 0 IJ e@ '.2 Q 9 Inspe: 'Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 7. 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tr_, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 171i-369 Project: . "T IA 11.7 0 t-i tJ tai Type of Inspection: '1.r.) AL, Address: . V;. *� L { On � 0 n\i Date Called: Special tnstructions: • _ rim /Ar'� • C6�eA1 -0(_ Date Wanted:. I1--2.a- 11 a.m. Requester: �0��� Phone No: 06, - ciy- 333 1 IDAppoved per applicable codes. 'COMMENTS: ECorrections required prior to approval. (1('.P I G J Date: / / -2Z' —( / EINSPECTION FEE REQUIRED. Pufor to next inspection. fee must be ' paid at 6300' Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER -- -- - • .:F4, 2e -4:.pi :1 .. . . • . : ... . . .p.a •- -..�,. wA :.;;;:.,:.;:��RR+4 —ice^ • INSPECTION RECORD Retain a copy with permit ti- - 381 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206 - 575 -4407 Project L. 1,J Sprinklers: Fire Alarm: Ty • -: •f Inspection: Address: /a q 00 Suite #: y e t- vtu� s CorAact Person: Special Instructions: ; Phone No.: -354- 330 roved per applicable codes. Corrections required prior to approval. COMMENTS: RA-c-ES o Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: . Permits: Occupancy Type: 1 Inspector: F.),... c-c9--_ Date: /2/1W/ / Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • • Fireproofing Aggregates Shotcrete Concrete M a s o n r y A s p h a l t R o o f i n P i l i n S t e e S o i l W o o d g g s December 27, 2011 File: 11 -341 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit No.: Ditch Witch N.W. 12900 48th Ave. S. 011 -389 RECEIVED DEC 30t DEVELOPMENT A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and /or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Oade45v- Kimberle Anderson President CC: Easy Up Storage -Roger Stuessi Tel: (425) 881 -5812 Fax: (425) 881 -5441 • 7126 180th Ave. NE • P.O. Box 2523 * Redmond, WA 98073 Client: Easy Up Storage 9883 40th Ave. S. Seattle, WA 98118 Contact: Roger Stuessi RECEIVED DEC 30 Ng i Field Report ogr" T,514 126 180th /Ave.N:E Project Number: 11 -341 Permit #: D11 -389 Project Name: Ditch Witch N.W. Address: 12900 48th Ave. S. Inspection Performed: Proprietary Anchors Date: 12/20/2011 Time: Temperature: Verified anchors to be Hilti KB -TZ 1/2" x 4 1/2" for rack and 3/8" x 3 3/4" for shelving. Verified hole cleanliness and embedment of 3 1/4" for 1/2" and 2" for 3/8 ". Torque was tested with calibrated wrench #132A and was found meeting 40 ft.-lb. requirement for 1/2" and 20 ft.-lb. for 3/8" anchors. All work was found in conformance with manufacturer's recommendations and ESR #1917. Distribution: Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Chandler, Loren Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden 12/26/2011 03:59 Fireproofing Aggregates Shotcrete Concrete Masonry A s p h a l t R o o f i n g P i l i n g S t e e l S o i l s W o o d 425 - 881 -5441 December 27, 2011 File: 11 -341 Building, Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit No.: Ditch Witch N.W. 12900 486 Ave. S. D11 -389 AAR TESTING LABORATO PAGE 02/04 A.A.R. TESTING LABORATORY, INC. rowinverrre INBPECt; I ANC MAMMA TESTING 'UJIONALLV nccEPlEb LAPCMTOnv This is to advise you that sp'ecia'l inspections are completed on the above referenced project. The following inspection was required and a copy of our report is attached: 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila. Building DepartMent,approved piens, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. Klmbei le Anderson President aode4sv- CC: Easy Up Storage -Roger Stuessi Tel: (425) 881 -5812 Fax: (425) 881 -5441 7126 180th Ave. NE ° P.O. Box 2523 * Redmond, WA 98073 12/26/2011 03:59 425 - 881 -5441 AAR TESTING LABORATO Field Report Report #: 53614 '�ija''�r,f•i�:_c_1'�_:f.:..l :.n� /��tl_i;:;: •C= •'i::.:j: :,��j'' _L�:,':`l�:ia., -;n: Client: Easy Up Stbtage 9883 40th Ave. S. Seattle. WA 98118 Canted: Roger Stuesel PAGE 03/04 Project Number: 11.341 Permit 0: D11-389 Project Name: Dttch WItbh N.W. Address: 12900 48111 Ave. S. Inspection Perforfied: Proprietary Anchors Data: 12/2012011 Time: Temperature: Verified anchors to be HIM KB•TZ 1/2" x 4112" for rack and 3/8" x 3 3/4" for shelving. Verified hole cleanliness and embedment of 3 114" for 1/2" and 2" for 3/8 ". torque•was tested with calibrated wrench #132A and was found meeting 40 ft.-lb. requirementfor 1/2" and. 20 ft.-lb. for 3/8" anchors. All work was found in conformance with manufacturer's recommendations and ESR #1917. Distribution: ( J Dilatribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Otelr Bute Owner I Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Chandler, Loren Reviewed by Mike Blackwell All reports are considered cortfidenti0l and are the property of the Client and A.A.R: Testing Labohttory. Inc. Reproduction except in full without the Written consent of A.A.R. Testing Is strictly fbrbiddel C:\ Users\ BEN \Dropbox\ Public \ACAD \DRAWINGS \R211311.dwg, 12/5/2011 12:40:12 PM • STORAGE RACK 3' -8' z J a U BRACE UPRIGHT 12' -0' z D J a L) 14 GA THK 3/8'x 5'x 8' BASEPLATE (2) 1/2'0 ANCHORS 1/8 r 1 -1/2' EA FACE COLUMN & BASE PL LOAD BEAM 1 -5/8'H x 1' W STEP 14 GA THICK PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 3400# CAPACITY @ 40', 75', 110', 144' 9' -0' LOAD BEAM ELEVATION C 1.5 x 1.5 1.5 14 GA THK I 2' OF 1/8' FILLET WELD EA END TO COLUMN BRACE (3) PIN CONN 0 0 1 -5/8x 3x o 3/16' THK PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATI ❑N STATING 1000# CAPACITY @ 40', 48', 58', 66' 3400# CAPACITY @ 75', 110', 144' 9' -0' LOAD BEAM tu 7 10' 2' -10' H 11' 2' -11' LOAD BEAM L 11' 10'[ cc 2' -11' 8' CO r m H i- 4' CONNECT OR 0 3' -4' 1 D _ LOAD BEAM CD z J U BRACE CONN (3) AISI A502 -2 RIVETS LOAD BEAM 7/16'0 2'oc HOOK THRU SLOTS IN COLUMN CONNECTOR 1/8V VERT EDGES LOAD BEAM ELEVATION 1/8 COLUMN 1 -1/2' 3/8x 5x 8 BASEPLATE (2) 1/2'0 ANCHORS 6'oc EA SIDE 5' i FF 3.25' 5' CONCRETE SLAB ON GRADE COLUMN BASE X- SECTION CONNECTOR SAFETY PIN TO RESIST 1000# UPLIFT LOAD COLUMN -BEAM CONN Perri! tint - _ s CON: REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 1 2011 City of Tukwila BUILDING DIVISION (n w F- O w 1- (4 1/1 CL W Cl, z Q 2 O - -CD U CL� 111 u U UJ UJ U J Ce J w Cw co W a, 0) > W A O CL w pg Kt th /tU CITY OF TUKWLA ULU 072011 PERMIT CENTER lt") 0 1-d x Q N o _J Ce eL Cn w f'or DITCHWITCH TUKWILLA, LOAD BEAM CONNECT OR LOAD BEAM 2'- \ `CONNECT OR LOAD BEAM 2'- \-CONNECTOR LOAD BEAM 2'- H UPRIGHT L T1 1- \-CONNECTOR t.3 a_ 3'- LOAD BEAM ELEVATION C 1.5 x 1.5 1.5 14 GA THK I 2' OF 1/8' FILLET WELD EA END TO COLUMN BRACE (3) PIN CONN 0 0 1 -5/8x 3x o 3/16' THK PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATI ❑N STATING 1000# CAPACITY @ 40', 48', 58', 66' 3400# CAPACITY @ 75', 110', 144' 9' -0' LOAD BEAM tu 7 10' 2' -10' H 11' 2' -11' LOAD BEAM L 11' 10'[ cc 2' -11' 8' CO r m H i- 4' CONNECT OR 0 3' -4' 1 D _ LOAD BEAM CD z J U BRACE CONN (3) AISI A502 -2 RIVETS LOAD BEAM 7/16'0 2'oc HOOK THRU SLOTS IN COLUMN CONNECTOR 1/8V VERT EDGES LOAD BEAM ELEVATION 1/8 COLUMN 1 -1/2' 3/8x 5x 8 BASEPLATE (2) 1/2'0 ANCHORS 6'oc EA SIDE 5' i FF 3.25' 5' CONCRETE SLAB ON GRADE COLUMN BASE X- SECTION CONNECTOR SAFETY PIN TO RESIST 1000# UPLIFT LOAD COLUMN -BEAM CONN Perri! tint - _ s CON: REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 1 2011 City of Tukwila BUILDING DIVISION (n w F- O w 1- (4 1/1 CL W Cl, z Q 2 O - -CD U CL� 111 u U UJ UJ U J Ce J w Cw co W a, 0) > W A O CL w pg Kt th /tU CITY OF TUKWLA ULU 072011 PERMIT CENTER lt") 0 1-d x Q N o _J Ce eL Cn w f'or DITCHWITCH TUKWILLA, C:\ Users\ BEN \Dropbox\ Public \ACAD \DRAWINGS \R211311.dwg, 12/5/2011 12:40:26 PM SHELVING TYPE "A" PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN C❑NSPICU ❑US L❑CATI ❑N STATING 150# CAPACITY @ 4', 30', 56', 84' 4' -0' 2' -0' '�1 MAX 7' -0' 7' -0' FRONT END ELEVATI ❑N 1 2.25' 1.38' EASY UP PARTS 2.5' 7/8' 0 /8 TYPE "B" PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN C❑NSPICU ❑US L❑CATI ❑N STATING 75# CAPACITY @ 4', 24', 44', 64', 84' 4' -0' 18' or- 7' MAX 7' -0' 2.25" x 2.50" x 0.13 " FOOTPL 12 GA. POST i'''0 HILTI TZ .6( CONCRETE WEDGE ANCHOR -0' FRONT END ELEVATI ❑N 12.5' EMB. d 1 5' CONCRETE FLOOR POST & BASE DETAIL REVIEVVED FOR CODE OMPLIANCE ROVED DEC 21 2011 BUILDING Tukwila VISION N W 0 z I I 11 I I I I I I RECEIVED C1TY OF TUK�LA DE.0 0 7 2011 :EuR: T CENTER W w e W A� o 1 N W CU W pq c� Cn w xQC� �w (4 o_JUJ CU> 0, W A W� � MI C_ 06 In o 3Z ZFAO u 1-1 I JIU W 1-1 W I >,Ja _J (4JWO oILQ Q 1- o \ U Cu U CbWW�W Cr, >pgCUC_ 0! W II W (4 Wa {!1 JWLLZ 0_ (4 1_ 0 1 -1 AQ Luce v) W � U C_ cz < Z z O A Z N I- Q U 2 �-, C_ W WQ WOZ�(4 r. .-� CU c) •- t!-) n EN. (4 w V) W V) W V) 0 W for DITCHWITCH TUKWILLA, 48th AVE S, LD 0 Calculations for : DITCHWITCH TUKWILLA, WA 12/05/2011 Loading: 3400 # load levels 4 pallet levels @ 40,75,110,144 Seismic per IBC 2009 100% Utilization Sds = 0.980 Sdl = 0.507 I = 1.00 108 " Load Beams Uprights: 44 " wide C 3.000x 3.000x 0.075 Columns C 1.500x 1.500x 0.075 Braces 5.00x 8.00x 0.375 Base Plates with 2- 0.500in x 3.25in Embed Anchor /Column 4.50x 2.750x 0.075 Load beams w/ 3 -Pin Connector by : Ben Riehl Registered Engineer REVIEWED FOR CODE COMPLIANCE APPROVED DEC 21 2011 City of Tukwila BUILDING DIVISION WA# 21008 RECEIVED CITY OF TUKVM' Ike 0 71011 PERMIT CENTER Cold Formed Channel Depth 3.000 in Fy = 55 ksi Flange 3.000 in Lip 0.750 in Thickness 0.0750 in R 0.1000 in COLUMN SECTION Blank = 9.96 in wt = 2.5 plf A = 0.747 in2 Ix = 1.191 in4 Sx = 0.794 in3 Rx = 1.263 in Iy = 0.935 in4 Sy = 0.544 in3 Ry = 1.119 in a 2.6500 Web w/t 35.3333 a bar 2.9250 Flg w/t 35.3333 b 2.6500 x bar 1.2423 b bar 2.9250 m 1.6690 c 0.5750 x0 - 2.9114 c bar 0.7125 J 0.0014 u 0.2160 x web 1.2798 gamma 1.0000 x lip 1.7202 R' 0.1375 h/t 38.0000 Section Removing: 0.640 inch slot 0.75 inches each side of center on web 0.375 inch hole 0.87 inches from web in each flange A- = 0.152 in2 A' = 0.595 in2 x bar = 1.478 in I'x = 1.014 in4 S'x= 0.676 in3 R'x= 1.305 in I'y = 0.743 in4 S'y= 0.476 in3 R'y= 1.117 in Cold Formed Channel Depth 1.500 in Fy = 55 ksi Flange 1.500 in Lip 0.000 in Thickness 0.0750 in R 0.1000 in Blank = 4.23 in wt = 1.1 plf ; ,.: r':' A = 0.317 in2 Ix = 0.125 in4 Sx = 0 166 in3 Rx = 0.627 in ly = 0.075 in4 Sy = 0 079 in3 Ry = 0.487bin a 1.1500 Web w/t 15.3333 • a bar 1.4250 Flg w/t 17.6667 b 1.3250 x bar 0.5060 b bar 1.4625 m 0.6531 c 0.0000 x0 - 1.1592 c bar 0.0000 J 0.0006 u 0.2160 x web 0.5435 gamma 0.0000 x lip 0.9565 R' 0.1375 h/t 18.0000 BRACE SECTION s In Upright Plane Seismic Load Distribution per 2009 IBC Weight I = Sds = 0.980 1.00 Allowable Stress Increase 1.00 R = 4.0 V = (Sds /R) *I *P1 *.67 60 # per level frame weight Columns @ 44 " Levels Load WiHi Fi FiHi Column: (inches) ( #) (k -in) ( #) (k -in) C 3.000x 3.000x 0.075 144 3460 498 887 128 110 3460 381 677 74 75 3460 260 462 35 KLx = 40 in 40 3460 138 246 10 KLy = 41 in 0 0 0 0 0 A= 0.595 in 0 0 0 0 0 Pcap = 16000 lbs - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 13840 1277 2272 247 Column 78% Stress Max column load = 12526 # Min column load = -1919 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -1218 # MIN 8791 # MAX -1919 # Anchors: 1 T = 1919 # 2 0.5 in dia HILTI TZ 3.25 "embedment in 2500 psi concrete Tcap = 2801 # 68% Stressed V = 1136 # per leg Vcap = 4858 # _ COMBINED = Braces: Brace height = 41 " Brace width = 44 " Length = 60 " P = 2329 # Use : C 1.500x 1.500x 0.075 A = 0.317 in L/r = 124 Pcap = 3155 # 74% OK 23% Stressed 62% Stressed B PAGE 1 MSU STRESS -11 VERSION 9/89 - -- DATE: 12/05/;1 - -- TIME OF DAY: 12:23 :14 INPUT DATA LISTING TO FOLLOW: Structure Storage Rack in Load Beam Plane 4 Levels Type Plane Frame Number of Joints 18 Number of Supports 10 Number of Members 20 Number of Loadings 1 Joint Coordinates 1 0.0 40.0 S 2 0.0 75.0 S 3 0.0 110.0 S 4 0.0 144.0 S 5 55.5 0.0 S 6 55.5 40.0 7 55.5 75.0 8 55.5 110.0 9 55.5 144.0 10 166.5 0.0 S 11 166.5 40.0 12 166.5 75.0 13 166.5 110.0 14 166.5 144.0 15 222.0 40.0 S 16 222.0 75.0 S 17 222.0 110.0 S 18 222.0 144.0 S Joint Releases 5 Moment Z 10 Moment Z 1 Force X Moment Z 2 Force X Moment Z 3 Force X Moment Z 4 Force X Moment Z 15 Force X Moment Z 16 Force X Moment Z 17 Force X Moment Z 18 Force X Moment Z Member Incidences 1 1 6 2 2 7 3 3 8 4 4 9 5 5 6 6 6 7 7 7 8 8 8 9 9 10 11 10 11 12 11 12 13 4 9 3 8 2 7 1 6 5 14 13 12 18 17 16 11 15 1 0 /d PAGE 2 MSU STRESS -11 VERSION 9/89 - -- DATE: 12/05/;1 - -- TIME OF DAY: 12:23:14 12 13 14 13 6 11 14 11 15 15 7 12 16 12 16 17 8 13 18 13 17 19 9 14 20 14 18 Member Properties 1 Thru 4 Prismatic Ax 1.038 Ay 0.727 Iz 2.599 5 Thru 12 Prismatic •Ax 0.595 Ay 0.298 Iz 1.014 13 Thru 20 Prismatic Ax 1.038 Ay 0.727 Iz 2.599 Constants E 29000. All G 12000. All Tabulate All Loading Dead + Live + Seismic Joint Loads 6 Force Y -1.730 7 Force Y -1.730 8 Force Y -1.730 9 Force Y -1.730 11 Force Y -1.730 12 Force Y -1.730 13 Force Y -1.730 14 Force Y -1.730 6 Force X 0.034 7 Force X 0.063 8 Force X 0.092 9 Force X 0.120 11 Force X 0.034 12 Force X 0.063 13 Force X 0.092 14 Force X 0.120 Solve PROBLEM CORRECTLY SPECIFIED, EXECUTION TO PROCEED Seismic Analysis per 2009 IBC wi di widi2 fi fidi # in # 3460 0.3088 330 68 21.0 34 68 3460 0.3998 553 126 50.4 63 126 3460 0.4594 730 184 84.5 92 184 3460 0.4912 835 240 117.9 120 240 0 0.0000 0 0 0.0 0 0 0 0.0000 0 0 0.0 0 0 13840 2448 618 273.8 g = 32.2 ft /sec2 T = 0.9558 sec I = 1.00 Cs = 0.0884 or Sdl = 0.507 Cs min = 0.098 or 1.5% R = 6 Cs = 0.0980 V = (Cs *I *.67) *W *.67 V = 0.0657 W *.67 = 618 # 0.1633 II 618 100% PAGE 3 MSU STRESS -11 VERSION 9/89 - -- DATE: 12/05/;1 - -- TIME OF DAY: 12:23:14 Structure Storage Rack in Load Beam Plane 4 Levels Loading Dead + Live + Seismic MEMBER FORCES MEMBER JOINT AXIAL FORCE SHEAR FORCE 1 1 0.000 -0.133 1 6 0.000 0.133 2 2 0.000 -0.056 2 7 0.000 0.056 3 3 0.000 -0.019 3 8 0.000 0.019 4 4 0.000 0.006 4 9 0.000 -0.006 5 5 6.821 0.304 5 6 -6.821 -0.304 6 6 5.106 0.246 6 7 -5.106 -0.246 7 7 3.400 0.174 7 8 -3.400 -0.174 8 8 1.703 0.060 8 9 -1.703 -0.060 9 10 6.821 0.314 9 11 -6.821 -0.314 10 11 5.106 0.304 10 12 -5.106 -0.304 11 12 3.400 0.250 11 13 -3.400 -0.250 12 13 1.703 0.180 12 14 -1.703 -0.180 13 6 -0.024 -0.148 13 11 0.024 0.148 14 11 0.000 -0.162 14 15 0.000 0.162 15 7 -0.009 -0.081 15 12 0.009 0.081 16 12 0.000 -0.105 16 16 0.000 0.105 17 8 -0.022 -0.052 17 13 0.022 0.052 18 13 0.000 -0.084 18 17 0.000 0.084 19 9 0.060 -0.022 19 14 -0.060 0.022 20 14 0.000 -0.049 20 18 0.000 0.049 MOMENT 0.00 - 7.41 0.00 -3.11 0.00 -1.07 0.00 0.31 0.00 12.16 3.56 5.04 2.73 3.36 0.78 1.27 0.00 12.56 4.51 6.13 4.02 4.73 2.59 3.53 - 8.32 -4.66 - 4.30 - 5.85 0.00 -3.07 -2.66 - 4.66 0.00 - 1.58 - 0.82 - 2.71 0.00 PAGE 4 MSU STRESS -11 VERSION 9/89 - -- DATE: 12/05/;1 - -- TIME OF DAY: 12:23:14 APPLIED JOINT LOADS, FREE JOINTS JOINT FORCE X FORCE Y 6 0.034 -1.730 7 0.063 -1.730 8 0.092 -1.730 9 0.120 -1.730 11 0.034 -1.730 12 0.063 -1.730 13 0.092 -1.730 14 0.120 -1.730 MOMENT Z 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 REACTIONS,APPLIED LOADS SUPPORT JOINTS JOINT FORCE X FORCE Y 1 0.000 -0.133 2 0.000 -0.056 3 0.000 -0.019 4 0.000 0.006 5 -0.304 6.821 10 -0.314 6.821 15 0.000 0.162 16 0.000 0.105 17 0.000 0.084 18 0.000 0.049 MOMENT Z 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 FREE JOINT DISPLACEMENTS JOINT X- DISPLACEMENT 6 0.3088 7 8 9 11 12 13 14 0.3998 0.4594 0.4912 0.3089 0.3999 0.4595 0.4910 Y- DISPLACEMENT - 0.0158 - 0.0262 - 0.0331 - 0.0364 - 0.0158 - 0.0262 - 0.0331 - 0.0364 SUPPORT JOINT DISPLACEMENTS ROTATION - 0.0021 - 0.0012 - 0.0009 - 0.0006 - 0.0019 - 0.0010 - 0.0006 0.0000 I3 PAGE 5 MSU STRESS -11 VERSION 9/89 - -- DATE: 12/05/;1 - -- TIME OF DAY: 12:23:14 JOINT X- DISPLACEMENT Y- DISPLACEMENT ROTATION 1 0.3088 0.0000 0.0006 2 0.3998 0.0000 - 0.0001 3 0.4594 0.0000 - 0.0005 4 0.4912 0.0000 - 0.0007 5 0.0000 0.0000 - 0.0104 10 0.0000 0.0000 - 0.0105 15 0.3089 0.0000 0.0014 16 0.3999 0.0000 0.0012 17 0.4595 0.0000 0.0012 18 0.4910 0.0000 0.0010 14- Beam - Column Check C 3.000x 3.000x 0.075 A = 0.595 in2 Sx = 0.676 in3 Rx = 1.305 in kx = 1.00 Stress Factor 1.000 Fy = Ry = ky = 55 ksi 1.117 in 1.00 Point P M Lx Ly Pcap Mcap Ratio 11 6.8 12.6 40.0 41.0 16.00 22.30 99% 12 5.1 6.1 35.0 41.0 16.00 22.30 59% 13 3.4 4.7 35.0 41.0 16.00 22.30 42% 14 1.7 3.5 34.0 41.0 16.00 22.30 26% 0 0.0 0.0 40.0 41.0 16.00 22.30 0% 0 0.0 0.0 40.0 41.0 16.00 22.30 0% Load Beam Check 4.50x 2.750x 0.075 A = 1.038 in2 Sx = 1.096 in3 Length = 108 inches Fy = E = Ix = 55 ksi 29,500 E3 ksi 2.599 in4 Pallet Load 3400 lbs Assume 0.5 pallet load on each beam M = PL /8= 22.95 k -in fb = 20.95 ksi Fb = 33 ksi Mcap = 36.15 k -in 48.20 k -in with 1/3 increase Defl = 0.36 in = L/ 297 63% w/ 25% added to one pallet load M = .232 PL = 21.30 k -in 59% 19 Base Plate Design Column Load Allowable Soil Assume Footing Soil Pressure 9.4 kips 1500 psf basic 30.0 in square on side 1500 psf Bending: Assume the concrete slab works as a beam that is fixed against rotation at the end of the base plate and is free to deflect at the extreme edge of the assumed footing, but not free to rotate. Mmax = wl"2/3 Use 5 "square base plate w = Load factor = Shear : 10.4 psi 1.67 1 = M = 5 in thick slab f'c = s = 4.17 in3 fb = Fb = 5(phi) (f'c".5) = Beam fv = Punching fv = Base Plate Bending 1 = fb = 35 psi Fv = 70 psi Fv = 10.02 in 582 # -in 2500 psi 140 psi 163 psi 85 psi 170 psi Use 0.375 " thick 1.5 in w = 376 psi 18037 psi Fb = 37500 psi OK !! OK !! OK !! OK !! �6 Calculations for : DITCHWITCH TUKWILLA, WA 12/05/2011 Loading: 3400 pallet levels @ 75 ", 110 ", 144" 1000 pallet levels @ 40 ",48 ",58 ",66" Seismic per IBC 2009 10096 Utilization Sds = 0.980 Sdl = 0.507 I = 1.00 108 " Load Beams Uprights: 44 " wide C 3.000x 3.000x 0.075 Columns C 1.500x 1.500x 0.075 Braces 5.00x 8.00x 0.375 Base Plates with 2- 0.500in x 3.25in Embed Anchor /Column 4.50x 2.750x 0.075 Load beams w/ 3 -Pin Connector by : Ben Riehl Registered Engineer WA# 21008 In Upright Plane Seismic Load Distribution per 2009 IBC Weight I = Sds = 0.980 1.00 Allowable Stress Increase 1.00 R = 4.0 V = (Sds /R) *I *P1 *.67 60 # per level frame weight Columns @ 44 " Levels Load WiHi Fi FiHi Column: (inches) ( #) (k -in) ( #) (k -in) C 3.000x 3.000x 0.075 144 3460 498 877 126 110 3460 381 670 74 75 3460 260 457 34 66 1060 70 123 8 KLx = 40 in 58 1060 61 108 6 KLy = 41 in 48 1060 51 90 4 A = 0.595 in 40 1060 42 75 3 Pcap = 16000 lbs - - -- - --- - - -- ==== 14620 - - -- - - -- - - -- 14620 1363 2400 256 Column 82% Stress Max column load = 13128 # Min column load = -1923 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = - 1220 # MIN 9248 # MAX - 1923 # Anchors: 1 T = 1923 # 2 0.5 in dia HILTI TZ 3.25 "embedment in 2500 psi concrete Tcap = 2801 # 69% Stressed V = Braces: 1200 # per leg Vcap = 4858 # = COMBINED = Brace height = 41 " Brace width = 44 " Length = 60 " P = 2460 # Use : C 1.500x 1.500x 0.075 A = 0.317 in L/r = 124 Pcap = 3155 # 78% OK 25% Stressed 63% Stressed In Upright Plane Seismic Load Distribution TOP LOAD ONLY per 2009 IBC Sds = 0.980 Weight I = 1.00 Allowable Stress Increase 1.00 R = 4.0 V = (Sds /R) *I *P1 60 # per level frame weight Columns @ 44 " Levels Load WiHi Fi FiHi Column: (inches) ( #) (k -in) ( #) (k -in) C 3.000x 3.000x 0.075 144 3460 498 890 128 75 60 5 8 1 66 60 4 7 0 KLx = 40 in 58 60 3 6 0 KLy = 41 in 48 60 3 5 0 A = 0.595 in 40 60 2 4 0 Pcap = 16000 lbs - - -- - - -- - - -- ==== 3760 - - -- - - -- - - -- 3760 515 921 130 Column 30% Stress Max column load = 4836 # Min column load = -1334 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -1848 # MIN 4856 # MAX -1848 # Anchors: 1 T = 1848 # 2 0.5 in dia HILTI TZ 3.25 "embedment in 2500 psi concrete Tcap = 2801 # 66% Stressed V = Braces: 461 # per leg Vcap = 4858 # = COMBINED = Brace height = Brace width = Length = P = Use : 41 " 44 " 60 " 944 # C 1.500x 1.500x 0.075 A = 0.317 in L/r = 124 Pcap = 3155 # 30% OK 9% Stressed 52% Stressed Base Plate Design Column Load Allowable Soil Assume Footing Soil Pressure 9.8 kips 1500 psf basic 30.7 in square on side 1500 psf Bending: Assume the concrete slab works as a beam that is fixed against rotation at the end of the base plate and is free to deflect at the extreme edge of the assumed footing, but not free to rotate. Mmax = w1'2/3 Use 5 "square base plate w = 10.4 psi Load factor = 1.67 Shear : 1 = M = 5 in thick slab f'c = s = 4.17 in3 fb = Fb = 5(phi) (f'cA.5) = Beam fv = Punching fv = Base Plate Bending 1 = fb = 36 psi Fv = 74 psi Fv = 10.37 in 624 # -in 2500 psi 150 psi 163 psi 85 psi 170 psi Use 0.375 " thick 1.5 in w = 394 psi 18904 psi Fb = 37500 psi OK !! OK !! OK !! OK !! 7,P Calculations for : DITCHWITCH TUKWILLA, WA 12/05/2011 Loading: 150 # load levels 4 shelf levels @ 4,30,56,84 Seismic per IBC 2009 100% Utilization Sds = 0.980 Sdl = 0.507 Uprights: I = 1.00 48 " Load Beams 24 " wide 2.25x 2.50x 0.100 Base Plates with 1- 0.375in x 2.50in Embed Anchor /Column by : Ben Riehl Registered Engineer WA# 21008 In Upright Plane Seismic Load Distribution per 2009 IBC Sds = 0.980 Weight I = 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 *.67 20 # per level frame weight Columns @ 24 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 170 14 36 3 56 170 10 24 1 30 170 5 13 0 4 170 1 2 0 0 0 0 0 0 0 0 0 0 0 680 30 74 5 Max column load = 538 # Min column load = -17 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -11 # MIN 401 # MAX -17 # Anchors: 1 V = T = Tcap = 17 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 2% Stressed 37 # per leg Vcap = 904 # = COMBINED = OK 4% Stressed 1% Stressed ZZ In Upright Plane Seismic Load Distribution TOP LOAD ONLY per 2009 IBC Sds = 0.980 Weight I = 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 20 # per level frame weight Columns @ 24 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 170 14 33 3 56 20 1 3 0 30 20 1 1 0 4 20 0 0 0 0 0 0 0 0 0 0 0 0 0 - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 230 16 38 3 Max column load = 240 # Min column load = -25 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -60 # MIN 244 # MAX -60 # Anchors: 1 V = T = Tcap = 60 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 8% Stressed 19 # per leg Vcap = 904 # = COMBINED = OK 2% Stressed 2% Stressed 2� Calculations for : DITCHWITCH TU KW I LLA, WA 12/05/2011 Loading: 75 # load levels 5 shelf levels @ 4,24,44,64,84 Seismic per IBC 2009 100% Utilization Sds = 0.980 Sdl = 0.507 I = 1.00 48 " Load Beams Uprights: 24 " wide 2.25x 2.50x 0.100 Base Plates with 1- 0.375in x 2.50in Embed Anchor /Column by : Ben Riehl Registered Engineer WA# 21008 In Upright Plane Seismic Load Distribution per 2009 IBC Weight I = Sds = 0.980 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 *.67 20 # per level frame weight Columns @ 24 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 95 8 20 2 64 95 6 15 1 44 95 4 10 0 24 95 2 6 0 4 95 0 1 0 0 0 0 0 0 - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 475 21 52 3 Max column load = 372 # Min column load = -8 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -0 # MIN 284 # MAX -8 # Anchors: 1 V = T = Tcap = 8 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 1% Stressed 26 # per leg Vcap = 904 # = COMBINED = OK 3% Stressed 0% Stressed 2� In Upright Plane Seismic Load Distribution TOP LOAD ONLY per 2009 IBC Sds = 0.980 Weight I = 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 20 # per level frame weight Columns @ 24 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 95 8 21 2 64 20 1 3 0 44 20 1 2 0 24 20 0 1 0 4 20 0 0 0 0 0 0 0 0 175 11 29 2 Max column load = 177 # Min column load = -14 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = - 42 # MIN 182 # MAX - 42 # Anchors: 1 V = T = Tcap = 42 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 5% Stressed 14 # per leg Vcap = 904 # _ COMBINED = OK 2% Stressed 1% Stressed Calculations for : DITCHWITCH TUKWILLA, WA 12/05/2011 Loading: 75 # load levels 5 shelf levels @ 4,24,44,64,84 Seismic per IBC 2009 1006 Utilization Sds = 0.980 sal = 0.507 I = 1.00 48 " Load Beams Uprights: 18 " wide 2.25x 2.50x O.1OC Base Plates with 1- 0.375in x 2.50in Embed Anchor /Column by : Ben Riehl Registered Engineer WA# 21008 In Upright Plane Seismic Load Distribution per 2009 IBC Weight I = Sds = 0.980 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 *.67 20 # per level frame weight Columns @ 18 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 95 8 20 2 64 95 6 15 1 44 95 4 10 0 24 95 2 6 0 4 95 0 1 0 0 0 0 0 0 - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 475 21 52 3 Max column load = 417 # Min column load = -53 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1 +0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = - 23 # MIN 307 # MAX - 53 # Anchors: 1 V = T = Tcap = 53 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 7% Stressed 26 # per leg Vcap = 904 # = COMBINED = OK 3% Stressed 1% Stressed In Upright Plane Seismic Load Distribution TOP LOAD ONLY per 2009 IBC Sds = 0.980 Weight I = 1.00 Allowable Stress Increase 1.00 R = 6.0 V = (Sds /R) *I *P1 20 # per level frame weight Columns @ 18 " Levels Load WiHi Fi FiHi (inches) ( #) (k -in) ( #) (k -in) 84 95 8 21 2 64 20 1 3 0 44 20 1 2 0 24 20 0 1 0 4 20 0 0 0 0 0 0 0 0 - - -- - - -- - - -- - - -- ---- - - -- - - -- - - -- 175 11 29 2 Max column load = 207 # Min column load = -44 # Uplift Overturning (. 6-. 11Sds )DL +(0.6- .14Sds).75PLapp- .51EL= (1 +0.11Sds)DL+ (1+0.14Sds).75PL+ .51EL = REQUIRED HOLD DOWN = -72 # MIN 212 # MAX -72 # Anchors: 1 V = T = Tcap = 72 # 1 0.375 in dia HILTI TZ 2.5 "embedment in 2500 psi concrete 794 # 9% Stressed 14 # per leg Vcap = 904 # = COMBINED = OK 2% Stressed 2% Stressed 29 CCityofTukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director December 9, 2011 Roger Stuessi 9883 40 Avenue S Seattle, WA 98118 RE: Incomplete Letter #1 Development Permit Application D11 -389 Ditchwitch NW —12900 48 Av S Dear Mr. Steussi, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on December 7, 2011 is determined to be incomplete. Before your application can continue the plan review process the attached /following items from the following department(s) need(s) to be addressed: Fire Department: Alan Metzler at 206 971 -8718 if you have any questions concerning the following comment: 1. Provide details of commodities /materials to be stored on racks. 2. Provide total height of storage. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Enclosures File: DI1 -389 W:\Permit Center\Incomplete Letters\20I 1\DI 1 -389 Incomplete Ltr #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 OPERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -389 DATE: 12/13/11 PROJECT NAME: DITCHWITCH NW SITE ADDRESS: 12900 48 AV S Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued ft4Ji(J D EPARTM TS: C�� C � iin !vision ire Prevention Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete N. Incomplete DUE DATE: 12/15/11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route, Structural Review Required 1, 1 No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/12/12 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -389 DATE: 12/07/11 PROJECT NAME: DITCHWITCH NW SITE ADDRESS: 12900 48 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division IN Public Works a t/W- 4 I Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete RI DUE DATE: 12/08/11 Not Applicable Comments: Permit Center Use Only /� �y INCOMPLETE LETTER MAILED: 1 4011 I( Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire k Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/05/12 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: / 2_// 3/// Plan Check/Permit Number: D 1 1 -3 89 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Ditchwitch NW Project Address: 12900 48 Av S Contact Person: RECEIVED CITY OF Tl14fffL4 DEC 13 2011 PERMIT ,t3Ft t, e,s1 " Phone Number: d` 1 6 - s' `t -333/ Summary of Revision: ,o r / — (� D wit a Jre"/ - /a_ s -1-0 e f ,lo ci 7-17 T r4 c - F_ Q 4. -1-.s / l9 2/i /AP-, i r� .4 s e.,,474- b ax es �c• 1.7 w✓ 2c <�, cr � , «� G 6 •9 0 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 1 \applications forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ENGINEERED PRODUCTS, A PAPE CO UBI No. 602684203 Phone 2063943300 Status Active Address 9883 40Th Ave So License No. ENGINPC931C0 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 2/20/2007 State WA Expiration Date 2/20/2013 Zip 98118 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ENGINSP142RA ENGINEERED STORAGE PRODUCTS CO Construction Contractor General Unused 12/1/1986 1/1/2000 Archived GADCOMH991K4 GADCO MATERIAL HANDLING LLC Construction Contractor General Unused 5/24/2001 1/3/2009 Expired ENGINPI013JK ENGINEERED PRODUCTS INC Construction Contractor General Unused 4/12/1999 1/6/2010 Out Of Business Business Owner Information Name Role Effective Date Expiration Date CT CORP SYSTEMS Agent 02/20/2007 Amount SALMAN, DAVID E President 02/16/2007 ZAGLB9124000 RIECKE, ROBERT J Secretary 02/16/2007 SAYLOR, THOMAS H Treasurer 02/16/2007 ARCH INS CO HOLLINGSHEAD, DANNY W Vice President 02/16/2008 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 FIDELITY is DEPOSIT CO OF MD 08748464 02/13/2007 Until Cancelled $12,000.00 02/16/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Arch Specialty Ins Co ZAGLB9124000 09/30/2011 10/30/2012 $1,000,000.00 10/05/2011 3 ARCH INS CO ZAGLB9118200 09/30/2010 09/30/2011 $1,000,000.00 09/24/2010 2 ARCH INS CO ZAGLB9070400 09/30/2008 09/30/2010 $1,000,000.00 09 /28/2009 1 TRANSPORTATION INS CO C2081198749 01/01/2007 01/01/2009 $1,000,000.00 12/21/2007 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: / /fortress.wa.gov /lni/bbip /Print. aspx 12/21/2011 4.4 VACINITY MAP BUILDING ELEVATION I 120th PI_ 124th Zt ir+ :'. 7C-..' .. ; W ;\ ::C: - .f.• It )...\ s ...? ••, ...am 4 ?4; i"i . i .)i .0 _. _...........J:._:..._.. ,.:;.:,..:,,.,.......;:: ,.. :Ipt,:7-1 d.---. 1 •,..1<li .. .. 1 1 2 IL ..-: , ..11..._ Li ...... „...1 -,:t, C2 ''. ..) ,*d. ., I I ■ ,.... 0 . 6 • ' :Li 1: -',.........,...,:"..,-, 1-:-/-7.-7.■'.•,,."..,:‘, ..... ,.... - '....!.::.\::'.. ... ": . .. • ...' ,......'...::,:,.1,: ,,,. $ .::' 8 loOth St,. ..,. s,,,„;. ,.. !,,...4......., ....„...„...„...,.„„..,..„...7, ..,)\ . 77, •; • 61%.4;,.,■..:„. N<N: i I k 't 49,-3D • •,',.. -Ot , '...',,,e.,.,:.... ',...:,... .. . ..,,,„\:.1:.. -: :..!,-,--,...,., ,\....1 ... .. pr--=-.--., •,... , . ..... ,...:..,.,0.-,ct, .. . . ...:s.,...L.:,51p.;,..;,—.. -,...f et-',.,<:,..r::;zt • ) 1/4..,./..... ' - f f ... 12;.128th ipothAL TOP OF LOAD. 15' 1 , 1,, NA,,t, , . t IV', ' S 1 38 i . c,. ; .., –., Riverton r 21' hat-- • 'I , if; . 11 • :1 1 81.137th $t t. I , t■•••••••••-•-•-• "."1"/ >;;;?..• aijh.1 • `---foiter 1./ 1 --- Eft 141' cP 'i • i 1 z.,-.I . , , ,. II 115,11 I, ''''''''1: 2] '' : ! 1 1 L.S4‘,L- , i ....- - C....:1 , , i __ I ,,,.. .. li ..,.... ....... ,;04':.--'t1)."---- 1 r- . 1E3' — 2" SEPARATE PERMIT REQUIRED FOR: Mektan NI Electrical l Plumbing tI Gas Piping City of Tukwila BUILDING DIVISION ' . . BUILDING STATISTICS OCCUPANCY CLASSIFICATION: CONSTRUCTION TYPE: FLOOR AREA: FIRST FLOOR (F-1) = FIRST FLOOR (B) = SECOND FLOOR (B) = TOTAL SQ FT = B (BUSINESS) F-1 (FACTORY INDUSTRIAL) V-B 3,144 SF 2,743 SF 958 SF 6,836 SF NUMBER OF STORIES: 2 MAX BUILDING HEIGHT (ABOVE FLOOR): 22'-0" FEET YES NO [ [ X ] FIRE ALARM SYSTEM: [ X [ • AUTOMATIC FIRE SPRINKLER SYSTEM: EGRESS SUMMARY FIRST FLOOR: TOTAL OCCUPANTS: 107 EGRESS WIDTH PER PERSON: 0.20 REQUIRED EGRESS WIDTH (IN INCHES): 21.4 (32 MIN.) ACTUAL EGRESS WIDTH. (IN INCHES): (7) 36" DOORS AT 33" NET = 231 SECOND FLOOR: TOTAL OCCUPANTS: STAIR WIDTH PER PERSON: REQUIRED STAIR WIDTH (IN INCHES): ACTUAL STAIR WIDTH (IN INCHES): 8 0.30 2.4 (36 MIN.) 42 FILE COPY No...p I I- 271A... 108" 108" 108" 108" ENGINEERED PRODUCTS A PAPS CO 9883 44TH AVENUE SOUTH Seattle, Phone: 206- 394 -3300 Fax: 206- 575 -6688 REVIEVVED–FOR CODE COMPLIANC APPROVED DEC 2 1 2011 Plen Approval of con the violation of any of BY ., to effors rind documents does not autivrize ;1,4141 ;AI or ordinance. Ron4fpt ‘4',! 4°44 •/, 4 #Virladilit;d: City OfThkwlIa BUILDING DIVISION FIRE ESCAPE PLAN REVISIONS No . shall b made to the moos of work without prior approve, of Tukwila Budding Division. Nan:: Revisions will rsquiro n rtsti pen subm!'7I and may Include allitional plan r5Vvy RECEIVED CITY OF TUKWILA DEC 0 71011 PERMIT CENTER DRAWN BY: CL SCALE: STATED DATE: 9/12/2011 JOB NO: 052605-001B CHECKED BY: JG SHEET NO. OF 3 SHEETS w 24 "x48" 24 "x48" 24 "x48" 24 "x48" 24"x48" 24 "x48" 24 "x36" 5' -6" N 02 02 24 "x48" 24 "x48" o2 24 "x48" 24 "x36" 24 "x36" 24 "x36" 24 "x48" 24 "x48" 24 "x36" 24 "x36" 4' -7" 3 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 21 2011 City of Tukwila BUILDING DIVISION tAi3 81 PLAN NORTH RECEIVED CITY OF TUKWILA urn; 0 7'.2011 PERMIT CENTER O 0 kW fct 0. 0. u) 1- 0 0. W ce W W z t9 z W 40TH AVENUE SOUTH t•r) oo 00 (0 CO (.0 ) r•-• 0 N • c 0 0 0 12900 48T1-1 AVE S TUKWILA, WA 98168 DRAWN BY: CL SCALE: 3/14»_ 1 -0„ DATE: 9/12/2011 JOB NO: 052605 -001 B CHECKED BY: JG SHEET NO. OF 3 SHEETS C:\ Users \BEN \Dropbox \Public\ACAD\ DRAWINGS \R211311.dwg 12/5/2011 12:40:12 PM STORAGE RACK 3' -8' z X J 0 BRACE UPRIGHT 12' -0' z 2 J a U 3/8"x 5'x 8' BASEPLATE (2) 1/2'16 ANCHORS COLUMN & BASE PL LOAD BEAM 1 -5/8'H x 1' W STEP 14 GA THICK PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS • LOCATION STATING 3400# CAPACITY @ 40', 75', 110', 144' LOAD BEAM ELEVATION C 14 .5 GA HK I—I 2" OF 1/8' FILLET WELD EA END TO COLUMN BRACE (3) PIN CONN 10' 1" 1' • Qi) BRACE CONN z X 0 PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 1000# CAPACITY @ 40 ", 48', 58', 66" 3400# CAPACITY @ 75', 110', 144' 9' -0' LOAD BEAM LOAD BEAM m 8 m 101: w m8' 1 01 o (3) AISI A502 -2 RIVETS 43 0 LOAD BEAM 7/16'0 2'oc HOOK THRU SLOTS IN COLUMN 1-5/8x 3x� O 3/16' THK 1/8V VERT EDGES 'CONNECTOR LOAD BEAM 2' -11" ID ID ID 2' -11" ID il I- ID to CONNECTOR w 3' -4' a a. 1 LOAD BEAM ELEVATION z a a 0 COLUMN 1/8 V1 -1/2' EA SIDE 3/8x 5x 8 BASEPLATE (2) 1/2'0 ANCHORS 6'oc FF 3.25' 5' CONCRETE SLAB ON GRADE COLUMN BASE X- SECTION SAFETY PIN TO RESIST 100041 UPLIFT LOAD COLUMN -BEAM CONN NOTES 1.) DESIGNED PER 2009 IBC & ASCE /SEI 7 -05 CHAPTER 15 2.) MATERIAL SPECS1 Fy = 55ksi ALL WELDS E70xx ELECTRODES 5" CONCRETE SLAB 2500psi ALLOW SOIL PRESSURE 1500psf 3J SEISMIC Sds =98Xg Sd1 =51Xg Design Cat. 'D" 4,) LOAD PER LEVEL: SEE NOTE ABOVE ELEVATIONS 5.) ANCHORS TO BE HILTI TZ MINIMUM OF 3,25" EMBEDMENT PER ESR #1917 SPECIAL INSPECTION IS REQ'd 12 -5 -11 EASY. UP STORAGE SYSTEMS for DITCHWITCH PAGE 1 12900 48th AVE S, TUKWILLA WA SHELVING TYPE "Ai PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 150# CAPACITY @ 4 ", 30', 56', 84' 4'-0' 7' -0" MAX 7' -0' FRONT END ELEVATION EASY UP PARTS 2.5' 2.25' 1.38" 0 7/8" 1/8 7' -0' TYPE "B" PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 75# CAPACITY @ 4 ", 24', 44 ", 64', 84' 4' -0" 18' or 4' MAX 2.25" x 2.50" x 0.13 " FOOTPL 12 GA. POST 8 "0 HILT! 12 CONCRETE WEDGE ANCHOR 2.5'EMB. 5• CONCRETE FLOOR 1 7' -O' FRONT END ELEVATION POST & BASE DETAIL gal cs 6 C M POI 1 ° !;aii � M 810 ogffig gscez REVIEWED 4R CODE POMPLIANCE ROVED DEC 21 2011 BUILDING °fi Tukwila DIVISION. 0 U 0 0. ddQ V♦ 1- V 0 0. 0 W oe W w z z w Seattle, WA 981 9883 40TH AVENUE SOUTH 206- 575 -6688 206 -394 -3300 0 L 0_ NOTES 1,) DESIGNED PER 2009 IBC & ASCE /SEI 7 -05 CHAPTER 15 2.) MATERIAL SPECS Fy = 55ksi ALL WELDS E70xx ELECTRODES 5' CONCRETE SLAB 2500psi ALLOW SOIL PRESSURE 1500psf 3,) SEISMIC Sds =98Xg Sd1 =51Xg Design Cat. "D" 4.) LOAD PER LEVEL) SEE NOTE ABOVE ELEVATIONS 5J ANCHORS TO BE HILTI TZ MINIMUM OF 2.5' EMBEDMENT PER ESR #1917 SPECIAL INSPECTION IS REQ'd 12 -5 -11 EASY UP STORAGE SYSTEMS for DITCHWITCH PAGE 2 12900 48th AVE S, TUKWILLA, WA 89 RECEIVED CITY OF MO RA DEC 0 72011 PERMIT CENTER D DRAWN BY: CL SCALE: STATED 12900 48TH AVE S DATE: 9/12/2011 TUKWILA, WA 98168 JOB NO: 052605 -001 B CHECKED BY: JG SHEET NO. • 3 OF 3 SHEETS LOAD BEAM Ok CONNECTOR LOAD BEAM 21- 2'- CONNECTOR LOAD BEAM m w `- CONNECTOR • LOAD BEAM 2'` H UPRIGHT L f-I13 CONNECTOR jW 3' -. LOAD BEAM ELEVATION C 14 .5 GA HK I—I 2" OF 1/8' FILLET WELD EA END TO COLUMN BRACE (3) PIN CONN 10' 1" 1' • Qi) BRACE CONN z X 0 PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 1000# CAPACITY @ 40 ", 48', 58', 66" 3400# CAPACITY @ 75', 110', 144' 9' -0' LOAD BEAM LOAD BEAM m 8 m 101: w m8' 1 01 o (3) AISI A502 -2 RIVETS 43 0 LOAD BEAM 7/16'0 2'oc HOOK THRU SLOTS IN COLUMN 1-5/8x 3x� O 3/16' THK 1/8V VERT EDGES 'CONNECTOR LOAD BEAM 2' -11" ID ID ID 2' -11" ID il I- ID to CONNECTOR w 3' -4' a a. 1 LOAD BEAM ELEVATION z a a 0 COLUMN 1/8 V1 -1/2' EA SIDE 3/8x 5x 8 BASEPLATE (2) 1/2'0 ANCHORS 6'oc FF 3.25' 5' CONCRETE SLAB ON GRADE COLUMN BASE X- SECTION SAFETY PIN TO RESIST 100041 UPLIFT LOAD COLUMN -BEAM CONN NOTES 1.) DESIGNED PER 2009 IBC & ASCE /SEI 7 -05 CHAPTER 15 2.) MATERIAL SPECS1 Fy = 55ksi ALL WELDS E70xx ELECTRODES 5" CONCRETE SLAB 2500psi ALLOW SOIL PRESSURE 1500psf 3J SEISMIC Sds =98Xg Sd1 =51Xg Design Cat. 'D" 4,) LOAD PER LEVEL: SEE NOTE ABOVE ELEVATIONS 5.) ANCHORS TO BE HILTI TZ MINIMUM OF 3,25" EMBEDMENT PER ESR #1917 SPECIAL INSPECTION IS REQ'd 12 -5 -11 EASY. UP STORAGE SYSTEMS for DITCHWITCH PAGE 1 12900 48th AVE S, TUKWILLA WA SHELVING TYPE "Ai PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 150# CAPACITY @ 4 ", 30', 56', 84' 4'-0' 7' -0" MAX 7' -0' FRONT END ELEVATION EASY UP PARTS 2.5' 2.25' 1.38" 0 7/8" 1/8 7' -0' TYPE "B" PERMANENT PLAQUE NOT LESS THAN 50 SQ INCHES IN AREA TO BE PLACED IN CONSPICUOUS LOCATION STATING 75# CAPACITY @ 4 ", 24', 44 ", 64', 84' 4' -0" 18' or 4' MAX 2.25" x 2.50" x 0.13 " FOOTPL 12 GA. POST 8 "0 HILT! 12 CONCRETE WEDGE ANCHOR 2.5'EMB. 5• CONCRETE FLOOR 1 7' -O' FRONT END ELEVATION POST & BASE DETAIL gal cs 6 C M POI 1 ° !;aii � M 810 ogffig gscez REVIEWED 4R CODE POMPLIANCE ROVED DEC 21 2011 BUILDING °fi Tukwila DIVISION. 0 U 0 0. ddQ V♦ 1- V 0 0. 0 W oe W w z z w Seattle, WA 981 9883 40TH AVENUE SOUTH 206- 575 -6688 206 -394 -3300 0 L 0_ NOTES 1,) DESIGNED PER 2009 IBC & ASCE /SEI 7 -05 CHAPTER 15 2.) MATERIAL SPECS Fy = 55ksi ALL WELDS E70xx ELECTRODES 5' CONCRETE SLAB 2500psi ALLOW SOIL PRESSURE 1500psf 3,) SEISMIC Sds =98Xg Sd1 =51Xg Design Cat. "D" 4.) LOAD PER LEVEL) SEE NOTE ABOVE ELEVATIONS 5J ANCHORS TO BE HILTI TZ MINIMUM OF 2.5' EMBEDMENT PER ESR #1917 SPECIAL INSPECTION IS REQ'd 12 -5 -11 EASY UP STORAGE SYSTEMS for DITCHWITCH PAGE 2 12900 48th AVE S, TUKWILLA, WA 89 RECEIVED CITY OF MO RA DEC 0 72011 PERMIT CENTER D DRAWN BY: CL SCALE: STATED 12900 48TH AVE S DATE: 9/12/2011 TUKWILA, WA 98168 JOB NO: 052605 -001 B CHECKED BY: JG SHEET NO. • 3 OF 3 SHEETS