Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0026 - DIGITAL FOREST
DIGITAL FOREST 12101 TUKWILA INTERNATIONAL BL EL1 0-0026 Parcel No.: 0923049031 Address: Suite No: Citylkf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Li ne: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us ELECTRICAL PERMIT 12101 TUKWILA INTERNATIONAL BL TUKW Permit Number: Issue Date: Permit Expires On: EL10 -0026 01/21/2010 07/20/2010 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: Contractor DIGITAL FOREST 12101 TUKWILA INTERNATIONAL BL , TUKWILA WA INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA KEVAN ARTHURS 56147AVS, SEATTLE WA VECA ELECTRIC CO INC 56147AVS, SEATTLE WA License No: VECAECI542MU Phone: Phone: 206 436 -5200 Phone: 206 860 -0231 Expiration Date: 10/31/2011 DESCRIPTION OF INSTALL NEW 800A WORK: SERVICE AND GENERATOR INSTALL GOB #92608) Value of Electrical: NRES: $155,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: 2008 $2,845.50 Date: � 1 U I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 ELI 0-0026 Printed: 01 -21 -2010 Parcel No.: 0923049031 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 12101 TUKWILA INTERNATIONAL BL TURIN DIGITAL FOREST Permit Number: Status: Applied Date: Issue Date: EL10 -0026 ISSUED 01/14/2010 01/21/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: / •24 doc: Cond -Elec ELI 0-0026 Printed: 01 -21 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. F12,0 -00 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1 210 t KV• ■ L1 t t4A-k CjLJ D King Co Assessor's Tax No.: oa2.99OL4 ""1,04 Suite Number: '4O 1 Floor: Tenant Name: D 1 U crAt U¶ UQf T Property Owners Name: C; —{ CZAZ :Je Tneil .Ots•-\ New Tenant: ❑ Yes Et.. No Mailing Address: 12201 "AAA L'P ItSTt- 'gW 0 11i1k4w \LOS•- City W Ps State °1?111b Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: KEVPr1--► S Mailing Address: 5614 7th Ave S Seattle, WA 98108 City State Zip Fax Number: (��A.0)-. (D3 ' ()SOS Day Telephone: (2. o )4 ' (0 ' 15200 E -Mail Address: lie Vo't Y1 . a1 Y- t,1'IU r"S veuA oy, ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA•Electric Co, INC Mailing Address: 5614 7th Ave S Seattle, WA 98108 Contact Person: Kt:VA t■ VV∎ 128 E -Mail Address: jC2VAY1 . OI r t%i l vs e Ve,CGt • W rYl Contractor Registration Number: VECAECI542MU City State Zip Day Telephone: `20.0) l S(c 52C50 Fax Number: 12-ao )n tp - 06c Expiration Date: 1 O I?J 1 /2_' 11 Valuation of Project (contractor's bid price): $ /CS-) (M) • DD pp Scope of Work (please provide detailed information): 3 , °V-t0 i 7 "' N E■ --",12._■1 ICE. Y GE/✓e/28TDR i-N STAGG - Will service be altered? ® Yes ❑ No Adding more than 50 amps? ® Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ® Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: ❑ Puget Sound Energy ® Seattle City Light H: WpplicationsWonns- Applications On Line41.2007 - Electrical Permit Application.doc bit IITenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Pennit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: � Date: /p—o/ Print Name: / /�v�'n / 'T 4.4 ' Da�j Telephone: Mailing Address: Sty / 7' ,4'e S T/ IDate Application Accepted: 011 11110 City it/A- State pit /di Zip Date Application Expires: VI .V4 ko H: ApphcatiousWonns- Apphcauous On LneW -2007 - Electrical Peewit Application.doc bh Staff Initials: --- 1?'^' Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049031 Permit Number: EL10 -0026 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 01/14/2010 Applicant: DIGITAL FOREST Issue Date: Receipt No.: R10 -00054 Payment Amount: $2,845.50 Initials: JEM Payment Date: 01/14/2010 12:31 PM User ID: 1165 Balance: $0.00 Payee: VECA ELECTRIC CO INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1320 2,845.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $2,845.50 2,276.40 569.10 PAYMENT RECEIVED doc: Receiot -06 Printed: 01 -14 -2010 INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 j,io ooZ6 C6 Project: VP! ( getcr Type of Inspection: Address: /240/ 1-:1•� • Date Called: �.. Special Instructions: r Date Wanted: 47 m: Requester: Phone No: V(I Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: �Ion�S tiV44>e 0 Date: D7/07/1 v ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 6UU -0026 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 17- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �'• /'� Type of Inspection: r(l,5 � [L P4Jcz Fu4 L5 - 1A166t..fr .B il,a /iI y sloJtc ( Address: 1M)1 -r:,. 3 . Date Called: pit-46,5 ,JAr F& 99c7Jai Special Instructions: K. PQ. dk Date Wanted: 770? rr 6.... Requester: Phone No: EApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: L6t/ u.M ©\ RJ6. , r(l,5 � [L P4Jcz Fu4 L5 - 1A166t..fr .B il,a /iI y sloJtc ( A-4p • of soffit c - me* vi Fa04fror Rn w pit-46,5 ,JAr F& 99c7Jai Date: 07/4/ I 0 Inspector: ri $60.00'REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 6AD-9)2-ta Project: II) � Type of Inspection: 7oo/Iloo Address: /2O , T 1.6 , Date Called: Special Instructions: Date Wanted: s �Z a.m • Requester: W1 9 -Mot r ie -- bzo U Id / 6oltA/ II Phone No: l Ain g/ t Fes, forPV24 Approved per applicable codes. Corrections required prior to approval. 1/ COMMENTS: 709! 044/, - dAlp RoitJ t' 46\16kkroKs‘ c?ily 7- - - / -r JJA6101\6 W1 9 -Mot r ie -- bzo U Id / 6oltA/ II roR ASP gi R65 c i a ►s reSo l Ain g/ t Fes, forPV24 Inspector: Date: d s,..-/a/0 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Coo -ooz6 Project: DUI Ppatsr" Type of Inspection: 7002— Address: I?.A o l I—. i . Date Called: Special Instructions: . Date Wanted: 2 03 a.rn,� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. -�- � COMMENTS• aki2-6 Lidt SrDE \)scs3srlaec;T moo � Inspector: ,../[ti & _ Date: r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ' M PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0026 DATE: 01 -14 -10 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: 1 �dinD#/??-1:11 I Public Works Fire Prevention Planning Division UStructural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Comments: Incomplete ❑ DUE DATE: 01-19-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route ri Structural Review Required ri No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions u Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DUE DATE: 02-16-10 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • 1 Page 1 of 3 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7TH AVE S PO BOX 80467 SEATTLE WA 98108 KING Corporation UBI No. Status 601190731 ACTIVE License No. VECAECI542MU License Type ELECTRICAL CONTRACTOR Effective Date 7/31 /1946 Expiration Date 10/31/2011 Suspend Date Specialty 1 GENERAL Specialty 2 UNUSED MASTER ELECTRICIAN INFORMATION License CONTIK *965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON AGENT 01/01/1980 929407110 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Cancelled ncelled $4,000.00 01/06/2007 6 TRAVELERS CAS Et SURETY CO 081S10352049701/06/2001 Until Cancelled 01/06/2007 $4,000.00 01/05/2001 5 UNITED PACIFIC U2800434 01/06/1998 Until Cancelled 01 /06/2001 $4,000.00 01/05/2001 hops: / /fortress.wa. gov /lni/bbip /Detail. aspx 01/21/2010 PERSKINE NOV 13, 2009 - I: \B15788 \CADD \E10.DWG ROOF AC -1 AC -2 AC -3 AC -4 r� r/ 4TH FLOOR REMOTE GENERATOR ANNUNCIATOR (IN UPS ROOM) DIGITAL METERING H3> H3 H3 2M4 2M4 (N3 180KW __L- _L._ UPS (TYP) UPS 1 (N3 -\ 180KW � __L_ UPS (TYP) UPS 2 4 % 12 MINUTE BATTERIES (TYP) H4 225A MCB T -1 30 KVA 480V- 208Y/120V 30 4W (B3 DC POWER C4 C4 B4 12 MINUTE BATTERIES (TYP) L4A 100A MCB L4B 100A DC POWER FUTURE 1 1 1 1 1 1 1 1 I IP (2M44� SYSTEM CONTROL CABINET U4 800A EXTERNAL MAINTENANCE BYPASS TVSS C3 PDU -1 75KVA 3 J PDU -2 75KVA 4 a H3 Q Q 00 1.0 CO Li I- QQ 00 "Ulf) N N ST( u_1 - ¢Q 00 LC) Ln N N ST( LLF °QQ 00 10 1.0 N N u_ °aQ 00 00 0000 I- < < 000 00 000 LL 1- °Qa �00 u1- u- Q<t << 00 ( IMO 00 N N *Kt- d" NN u 1- 1 L.1- QQ <Q 101.0 10 to in 1 N N N N w w I (f) << ( u7 u7 N N IIj 1- �<< ( N N N N ( w 0 cn LPL I- << ir) f) N N N N w 0 << 1 Ln uf) NN N N w w 1 Q ( Ln LO N N N N G 10 11 12 13 14 15 16 17 18 19 20 21 SWBD 4D1 480Y/277V, 30, 4W, 65KAIC, 2000A T, C3 r - - - - - PDU -3 I I 1 I 1 1 I I 75KVA I I <Ji C3 � t C3 r \\ ' � 1 t C3 PDU -4 75KVA <12� PDU -5 75KVA - - J PDU-6 75KVA -_4_ -- <4 C3 T C3 7 \ , 1 r - - -I- r- --� - -1 I I I I PDU -7 ; ; PDU -8 I 1 I 1 I I I I I I I I I I I I 75KVA 75KVA I I I I L - , _ _ J L - - - J FELE COPY Permit No. fLIO. &AAP Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditio : is ack (edged: By Date: D City Of Tukwila BUILDING DIVISION LEVEL P -2 5N4 2000A -4P 65KAIC METERING COMPARTMENT PER SEATTLE CITY LIGHT REQUIREMENTS TVSS BYPASS/ ISOLATION SWITCH LIGHTNING ARRESTER 0 O 0 N DIGITAL METERING TO SCL SWBD MSB -2 480Y/277V, 30, 4W, 65KAIC, 2500A 5N4 6M4 200A 200A 100A 100A 125A REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal' and may i lc'sude additional plan review fees. n FEEDER SC -EDUCE FEEDER COPPER CONDUCTORS AMPACITY NO. CONDUIT WIRE NOTE 2 A4 1" 4 - #4, 1#8 G. 70 A3 1" 3 - #4, 1#8 G. 70 B4 1 1/4" 4 - #2, 1 #6 G. 115 B3 1 1/4" 3 - #2, 1 #6 G. 115 CH 2" 3 - #1, 1#1/0 N, 1#6 G. 120 C4 1 1/2" 4 - #1, 1 #6 G. 130 C3 1 1/2" 3 - #1, 1 #6 G. 130 D5 2" 5 - #1/0, 1 #6 G. 136 D4 1 1/2" 4 - #1/0, 1 #6 G. 150 D3 1 1/4" 3 - #1/0, 1 #6 G. 150 E5 2" 5 - #2/0, 1 #6 G. 156 E4 2" 4 - #2/0, 1 #6 G. 175 E3 2" 3 - #2/0, 1 #6 G. 175 F5 2" 5 - #3/0, 1 #6 G. 180 F4 2" 4 - #3/0, 1 #6 G. 200 F3 1 1/2" 3 - #3/0, 1 #6 G. 200 G5 2 1/2" 5 - #4/0, 1 #6 G. 208 G4 2" 4 - #4/0, 1 #4 G. 230 G3 2" 3 - #4/0, 1 #4 G. 230 H5 3" 5- 250kcmil, 1 #4 G. 232 H4 2 1/2" 4- 250kcmil, 1 #4 G. 255 H3 2 1/2" 3- 250kcmil, 1 #4 G. 255 J5 3" 5- 300kcmil, 1 #4 G. 256 J4 3" 4- 300kcmil, 1 #4 G. 285 J3 3" 3- 300kcmil, 1 #4 G. 285 K5 3" 5- 350kcmil, 1 #4 G. 280 K4 3" 4- 350kcmil, 1 #4 G. 310 K3 3" 3- 350kcmil, 1 #4 G. 310 L5 3" 5- 400kcmil, 1 #2 G. 304 L4 3" 4- 400kcmil, 1 #2 G. 335 L3 3" 3- 400kcmil, 1 #2 G. 335 M5 3 1/2" 5- 500kcmil, 1 #2 G. 344 M4 3" 4- 500kcmil, 1 #2 G. 380 M3 3" 3- 500kcmil, 1 #2 G. 380 N5 4" 5- 600kcmil, 1 #2 G. 380 N4 3 1/2" 4- 600kcmil, 1 #2 G. 420 N3 3 1/2" 3- 600kcmil, 1 #2 G. 420 2H5 (2) 3" 5- 250kcmil, 1 #2 G. EA. 464 2H4 (2) 2 -1/2" 4- 250kcmil, 1 #2 G. EA. 510 2H3 (2) 2 -1/2" 3- 250kcmil, 1 #2 G. EA. 510 2J5 (2) 3" 5- 300kcmil, 1 #2 G. EA. 512 2K5 (2) 3" 5- 350kcmil, 1 #1 G. EA. 560 2K4 (2) 3" 4- 350kcmil, 1 #1 G. EA. 620 2K3 (2) 2 -1/2" 3- 350kcmil, 1 #1 G. EA. 620 2M4 (2) 3" 4- 500kcmil, 1 #1/0 G. EA. 760 2M3 (2) 3" 3- 500kcmil, 1 #1/0 G. EA. 760 2N4 (2) 3 -1/2" 4- 600kcmil, 1 #1/0 G. EA. 840 2N3 (2) 3 -1/2" 3- 600kcmil, 1 #1/0 G. EA. 840 3L4 (3) 3" 4- 400kcmil, 1 #2/0 G. EA. 1005 3L3 (3) 3" 3- 400kcmil, 1 #2/0 G. EA. 1005 4H4 (4) 2 -1/2" 4- 250kcmil, 1 #2/0 G. EA. 1020 4H3 (4) 2 -1/2" 3- 250kcmil, 1 #2/0 G. EA. 1020 4K4 (4) 3" 4- 350kcmil, 1 #3/0 G. EA. 1240 4K3 (4) 3" 3- 350kcmil, 1 #3/0 G. EA. 1240 4N4 (4) 3 -1/2" 4- 600kcmil, ,1 #4/0 G. EA. 1680 4N3 (4) 3 -1/2" 3- 600kcmil, 1 #4/0 G. EA. 1680 5N4 (5) 3 -1/2" 4- 600kcmil, 1 #250 G. EA. 2100 5N3 (5) 3 -1/2" 3- 600kcmil, 1 #250 G. EA. 2100 6M4 (6) 3" 6- 500kcmil, 1 #250 G. EA, 2280 6N4 (6) 3 -1/2" 4- 600kcmil, 1 #350 G. EA. 2520 6N3 (6) 3 -1/2" 3- 600kcmil, 1 #350 G. EA. 2520 EXTEND CONDUIT AND WIRE NEW LOCATION IN GENERAT ROOM. SEE SHEET E2.0. DP2 800A, 480V/277V, 30, 4W, 65KAIC 750KW LOAD BANK 2000A BUSWAY CT CABINET. LOCATE SEATTLE CITY LIGHT REQUIREMENTS. /REMOTE METER PER SEATTLE CITY LIGHT REQUIREMENTS. / PROVIDE TIME DELAY f/ NEUTRAL STYLE ATS 800A- 4P BYPASS/ o ISOLATION ATS, 65KAIC \--1250KW/1563KVA ENGINE /GENERATOR SWBD G -1 480Y/277V, 30, 4W, 65KAIC, 2000A MSB -3 800A ENCLOSED CB 480Y/277V, 30, 4W 65KAIC STANDBY POWER RISER DIAGRAM SCALE: NONE SWBD G -2 800A, 480Y/277V, 30, 4W, 65KAIC NEW SERVICE SCHEDULE NOTES: 1. CONDUIT SIZING BASED ON RIGID GALVANIZED STEEL CONDUIT TYPE THHN -2 /THWN -2 AND XHHW WIRE TAKING INTO ACCOUNT BOTH CONDUIT FILL AND JAMB RATIO. 2. AMPACITIES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE 310 -16. A. 60° RATING FOR TERMINATION TO DEVICES © 100A OR LESS PER UL. B. 75° RATING FOR 3W AND 4W FEEDERS. C. 90° RATING FOR 5W FEEDERS DE -RATED TO 80% WHERE PREDOMINATLY HARMONIC CURRENTS ARE PRESENT. NEUTRALS > #1/0 ARE PARALLED ON 5W FEEDERS. 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFICULT OR LONG PULLS. 4. GROUND WIRE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC TABLE 250 -95. 5. PROVIDE A SEPERATE ISOLATED GR CONDUCTOR ON ALL FEEDERS SHO EVIEWED R WITH COMPLIANCE W 6. INCREASE GROUND SIZE FOR GROU DINGNFPA70 - NEC ELECTRODES PER NEC TABLE 250 - 4. FLAG NOTES: 3 "H CONCRETE HOUSEKEEPING PAD. COORDINATE INSTALLATION REQUIREMENTS WITH SEATTLE CITY LIGHT, 3 PANEL PDU. ® 2 PANEL PDU. SQUARE D 2350 WITH IOM -4444 I/O MODULE. JAN 2 0 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 142010 PERMIT CENTER LlOOO2Sb SPARLING WORK TOGETHER 1 STAND APART 720 Olive Way, Suite 1400 Seattle, Washington 98101 -1853 206.667.0555 800.667.0610 www.sparling.com CONSULTANTS REVISIONS ISSUE DATE -- All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same moy not be duplicated, used or disclosed without the written concent of the Sabey Corporation. Tenant Improvement for DIGITAL FOREST at Intergate West 12101 Tukwila International Blvd. Tukwila, WA DRAWING TITLE: STANDBY POWER RISER DIAGRAM PROGRESS DATE: FILE: E10.DWG PLOT: PROJECT NUMBER: DRAWN BY: KM CHECKED BY: TJ APPROVED BY: DRAWING NUMBER: BY: KMADSON OCT 05, 2009 - 09:04:05 AM I: \B15788 \CADD \E20.DWG 1) BYPASS CABINET & CB 2) (2) 3 i" CONDUIT FOR GENERATOR FED TO ATS 3) ROUTE OF CONDUITS FOR: - NEW SERVICE - GENERATOR FEED - UPS OUTPUT TO LEVEL 4 NEW SERVICE 4) EXISTING RISER -UPS OUTPUT CONDUITS TO L-4 STAIRWAY P202 G ELECTRICAL ELEVATOR LOBBY AMA ELEC EXISTING (2) 4"C INSTALL B L & I REQUIR I I MSB-2 CT CABINET (MOUNTED ABOVE) 01111111111/1 MSB-3 800A ENCLOSED CIRCUIT BREAKER (MOUNTED BELOW) ER PER MENTr REMOTE SCL ME R NAV GARAGE P201 RELOCATdD EQUIPMENIT BATTERY CHARGER BLOCK 0 rb■S4. ""' • rA 1.1 -800A- 'ILIN•maolavz20=7.nrc GElt ER 413 TO 'EMOTE AN NCIATOR r "rAyoRmi 41114:1114MINarAIIIIr AIVAII4111rAllWailler 00' HEATER NEW GENERATOR Y.10/11111931M9P/0119111VAINIIMMINNAILIIIIIIIIIII'SI1M1111111111111111111 PORTABLE GENERATOR CONNECTION SERVICE HEAD BUS WAY GENERATOR SERVICE DISCONNECT 10'x3/4" GROUND ROD (TYP OF 4) PROVIDE 6" DIAMETER CONCRETE-FILLED PIPE 0 BOLLARDS. BOLLARDS SHALL EXTEND 3 FEET ABOVE FINISHED GRADE AND 3 FEET BELOW. MOUNT IN 36" X 15" DIAMETER CONCRETE BASES. MAX 0 0 #4/0 (TYP) 0 0 0 PROVIDE CONCRETE HOUSEKEEPING PAD PER GENERATOR MANUFACTURER'S RECOMMENDATIONS. (T ROOM-POWER REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 2 0 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2010 PERMIT CENTER ELIO-• 0()24 ) SPARLING WORK TOGETHER 1 STAND APART 720 Olive Way, Suite 1400 Seattle, Washington 98101-1853 206.667.0555 800.667.0610 WWW.sparling.com CONSULTANTS REVISIONS ISSUE DATE — All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concent of the Sabey Corporation. Tenant Improvement for DIGITAL FOREST at Intergate West 12101 Tukwila International Blvd, Tukwila, WA DRAWING TITLE: SYMBOLS AND ABBREVIATION AS BUILT REVISIONS 12,21,09 PROGRESS DATE: FILE: E20.DWG PLOT: PROJECT NUMBER: 615788 DRAWN BY: KM CHECKED BY: TJ APPROVED BY: DRAWING NUMBER: E2O 1100MIN11.691 lit=t7111411.01.1.1=891111MAI=1 15=111=1.08,10=99111014011591.1.1010MS CIMED11144118129111.44M=111.84.1 610.1.04010.11811.400998642( GUAU. COICFERENCE ROOM LARGE CONFERENCE ROOM ELL-G. ROOM ULM/DATA millaswassimmassousgs (DE BELOW) (DECK Ea_ciu) (DEC( I3ELCW) (PECK EELORD (DEG BELOW) PISINOMMIOHNIMSPOMMESSii= CK DE1=910111=1061IIZERNIM=Maint=1.1641 0=-10E LEVE 1" - 3/32" 4 IMONSSIS===i011121=191410.684.200191.24.0180=11011 DRAWING REVISIONS £U� 00z (0 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JAN 2 0 2010 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKVVILA JAN 1 4 2010 PERMIT CENTER d z DRAWING SUBMITTALS DRAWING REVISIONS 0 z SUBMIT FOR PERMIT SUBMIT FOR BID SUBMIT FOR CONSTRUCTION 4TH LEVEL FLOOR PLAN -J Z CO 22 1— co <a) < < 1— 0 (•1 (•1 JOB NO: 09053003 ENGINEER: D.K. DRAWN: L.M. DATE: 11-19-09 SHEET NO: Al