Loading...
HomeMy WebLinkAboutPermit EL10-0081 - WESTFIELD SOUTHCENTER MALL - SHIEKH SHOESSHIEKH SHOES 984 SOUTHCENTER MALL EL1 0-0081 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us Parcel No.: 9202470010 Address: 984 SOUTHCENTER MALL TURIN Suite No: ELECTRICAL PERMIT Permit Number: EL10 -0081 Issue Date: 03/15/2010 Permit Expires On: 09/11/2010 Tenant: Name: SHIEKH SHOES Address: 984 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Phone: Address: 11601 WILSHIRE BL, 12TH FLOOR , LOS ANGELES CA Contact Person: Name: BRUCE MARTENEY Phone: 909 - 599 -7054 Address: 425 W BONITA AVE #106 , SAN DIMAS CA Contractor: Name: MILESTONE ELECTRIC Phone: 503 645 -5323 Address: 1800 NW 169 PL STE B700 , BEAVERTON OR Contractor License No: MILESE *978R3 Expiration Date: 12/29/2011 DESCRIPTION OF WORK: ELECTRICAL FOR TENANT IMPROVEMENT Value of Electrical: NRES: $25,000.00 Fees Collected: $653.13 RES: $0.00 Type of Fire Protection: UNKNOWN National Electrical Code Edition: 2008 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: / Date: 0191 1 S ` W I hereby certify that I have read and x fined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • wit , whether specified herein or not. The granting of this permit does not pre me to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am autho ' d to sign and obtain this electrical permit. Signature: .-r' -(Va: Date: 7.0 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 ELI0 -0081 Printed: 03 -15 -2010 Parcel No.: 9202470010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 984 SOUTHCENTER MALL TUKW SHIEKH SHOES PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0081 ISSUED 02/04/2010 03/15/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be m accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 0 doc: Cond -Elec ELI 0-0081 Printed: 03 -15 -2010 CITY OF TUKWILA Community Developmen Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ;SITELOCATIO Site Address: King Co Assessor's Tax No.: aWC17^ �© Suite Number:1 t4 6 Floor: Q t■\ New Tenant: 'R Yes .. No Tenant Name: Property Owners Name:W r \F C 11 Mailing Address: 1 \ `p O \ \J rjp � €_ �j 1 V C S c ktN e `e S aik g0025 City State Zip O‘1TACT PER`SONal who do we contact when your permit is ready to be issued • Name: 1^ \ C°.- KA CZ-7E j∎ F 1 Day Telephone: 4 O 5°J9 O 3 Mailing Address: \.25 \1''J r So t--‘-k k /e_ - (O�, S� 1�11iTES CA, f 1 City State Zip E -Mail Address: Fax Number: al Og Scr) —OZ.—/ S :ELECTRICAL CONTRACTOR INFORMATIO Company Name: t 0 Maili.ng Address: A, 1 Pk •\ AR 1-Tr c c- Contact Person: 's. 1 0 17\<0 E -Mail Address•. \ M 1 TAO C\XCIAk) OpWI, Contractor Registration Number: r • • City State Zip Day Telephone: u 8D_ \'k 3 3 ?5 Fax Number: 14s b 1 tk + o2_,0 Expiration Date: Valuation of Project (contractor's bid price): $ as 7 0 O( Scope of Work (please provide detailed information): Will service be altered? ❑ Yes Type of Use: Type of work: [] New ❑ Addition ❑ Service Change ❑ Remodel [] Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Adding more than 50 amps? Yes ❑ No Property Served by: Puget Sound Energy [1 Seattle City Light H: Applications\Forms- Applications On Line\2010 Applications \I -2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Tenant Improvement ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings $152.85 $81.90 ea $59.85 ea ❑ Low voltage systems (alarm, furnace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACT R: Signature: Print Name: Mailing Address: S 0 0. 1 kl_0164-N Date: c� p9 Day Telephone: a O& 1 list 3 ^ C�l7f State Zip Date Application Accepted: -L -1-t6 Date Application Expires: U Staff Initials: H:\Applications \Forms - Applications On Line\2010 Applications \I -2010 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0081 Address: 984 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/04/2010 Applicant: SHIEKH SHOES Issue Date: Receipt No.: R10 -00439 Payment Amount: $522.50 Initials: WER Payment Date: 03/12/2010 10:55 AM User ID: 1655 Balance: $0.00 Payee: HINKLE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 012024 ACCOUNT ITEM LIST: Description 522.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 522.50 Total: $522.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 03 -12 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0081 Address: 984 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/04/2010 Applicant: SHIEKH SHOES Issue Date: Receipt No.: R10 -00188 Payment Amount: $130.63 Initials: WER Payment Date: 02/04/2010 12:19 PM User ID: 1655 Balance: $522.50 Payee: A & D INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7773 130.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 130.63 Total: $130.63 PAYMENT RECEIVED doc: Receiot -06 Printed: 02 -04 -2010 INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 6o-odgi Project: 3f4f6x14 5140E5 Type of Inspection: 2-t'00 v Address: / Date Called: Special Instructs ns: Date Wanted: 3 v f a.m. ` p. , Requester: Phone No: 5.4 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 00Aadort 0 fi Pt-P6 Inspector: /J61\ Date: 0 Li/34 O El $60.00 REINSPECTION FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 6AD ON1 PERMIT NO. L\6 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: _ 6-K1 S�e� T 01v Type of Inspection: v Address: tittlA, Date Called: 1 Special Instructs ns: Date Wanted: �rj 2 A Vim. t /_P Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:/ 7 6041 LV I ( Date: off 21 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. lid Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (pf Project:5414. CVO C> Type of Inspection: 1 ©O Address: Iii ii ti Date Called: Special Instructions: Date Wanted: q, .m. ('j Requester: Phone No: ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Date: ti t0 biSs ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: t- .."-- e.- '+a,.- "..'_.�^- _'' =�... ,< —„ws., `5 s?,- .;;w.-c_„_ wn; rT' t^.^. r�: ti..: Yr.--^-"' kr:: �T ...,.- F"•:+�..,..- .r.,-- . =. ^�_a 8 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6,10-0011 PERMIT NO. CITY OF TUKWILA BUILDING DIVISIONc 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project � ��! t �,�� IT Type of Inspection: �� ©O Address: ti Date Called: Special In truc ons: Date Wanted: 7 17 Cr-.... Requester: Phone No: EjApproved per applicable codes. COMMENTS: Corrections required prior to approval. 64,M KUOFTo P Ac,ctss Co v Psis Ion J I4 I - Wodt, A A tkoNA vF Fit AtID 6iELE c ibl1tiriiJ(1 Alt) �l CaIJ460 on/ �7 - (.%J o'5 t'ARO-CT164,5 t'10 )& Inspector: must 4r180446\ $60.00 REINSPECTION FEE REQUIRED. Prior p t be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: DLl Z'j iO to ins ec ion fee Receipt No.: Date: INSPECTION-RECORD Retain a copy with permit INSPECfiION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (tia-Dal Project: S l fK, 1 . <p.065 Type of Inspection: /D` t Address: 7yLi / Date Called: . - LAM., F WAY-ER, Oct I E r-� Special Instructi ns: • Date Wanted: / ZZ a.m P.m. Requester: � i )-1-1d Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pada- i C/ L4 OA/ gam g _ - is\1) 'phtsciDIJn1Et.7" To Reiticr 4 6, �� . - LAM., F WAY-ER, Oct I E kfur.. A .4-IIl.x1a -rte of 616i(if ict L,t terif\kA ttrIV 4-vARti S ` b ERS ina rak sTo o RPTtt-CA.- � i )-1-1d nspector: Date: d 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .,.,....,_. o,., z... e"' 4�- t" x�r* tc-.!',^.,.. C.- s! ..v- ..�vv..._r,...- t�- +"t -`.J`5 -ate ' wsz`!^.r.- �n- •.._.:- x^ >n - °, r,..:..s..:",,x INSPECTION :RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 50.1 ,kf J `�63 G Type of Inspection: .. /00, Address: Date Called: Special Instructions: Date Wanted: � O� p.m. Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. 2 z rogleoz_01.)-r- KdJblo- t4 Cohpet Inspector: Date: OLI 07 ( O El $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit (uo-odif PERMIT NO. CITY OF TUKWILA BUILDING DIVISION \ l2 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project:6'/,k,4 z._...„ Type of Inspection: 70 3 Address: yy t/414/ Date Called: Special Inst uctidns: Date Wanted: AL amm. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ' CtJ\/& -rbfRir Dct - Co,0.4 d hcce55 i&74"Jer\ ❑ $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Date: Receipt No.: Date: ^t»r.+l.:^ -«�,t. x ...n'L'i: •<.�as^rr2h; in.3'*"ti ^... ra�_.n_ _ aw?: i�x 4- r- .`:`�,4'c- •ur,-�� 3.h.+�w.^s: .n --�,. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6LIO-OO(t PERMIT NO: CITY OF TUKWILA BUILDING DIVISION �G- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 54't14 5 4 Type of Inspection: 7 00 3 Address: (Jil rliku Date Called: Special Instru Lions. Date Wanted: 3 ��a rr p.m. Requester: uovt.6 t L- Phone No: 30eC I-r- Approved per applicable codes. Corrections required prior to approval. COMMENTS: i. 0.,K, r uovt.6 t L- 30eC I-r- 6)(66-pi ST0 tefl4r Inspector: //l /C:✓ J/n Date: ©3/I 7 v ri $60.00 REINSF1ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: S,{':? i`.:7.,�a- •s�_.,,.:r�•:e*3s. fr�"'r"`?"".d._. -,..mac • • COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0081 DATE: 02 -04 -10 PROJECT NAME: SHIEKH SHOES SITE ADDRESS: 984 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: W LO 43$uilding Divisisi on Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02 -09 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route k Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-09-10 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Milestone Electric 5036455323 1800 Nw 169Th Pl Ste B700 Beaverton Or 97006 Out Of State Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602346333 Active MILESE *978R3 Electrical Contractor 12/23/2003 12/29/2011 General Unused ADMINISTRATOR INFORMATION License FOX'AAJ9230B Name Fox, Adam J Status Active Business Owner Information Name Role Effective Date Expiration Date Coleman, William A Partner /Member 12/23/2003 4/30/2008 Crouser, Charles D Partner /Member 12/23/2003 $250.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY a INDEM CO 554835C 12/08/2003 Until Cancelled $4,000.00 12/23/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EROBA00439 4/30/2008 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 03/15/2010 PUSHBUTTON 0 48" A.F.F. WIRED TO '!! BUZZER 0 CASHWRAP NOTE TENANT'S ELECTRICAL CONTRACTOR TO REPLACE ALL NON CODE COMPL I ANT EQU I PMENT AT TENANT COST. NOTE: ALL UNUSED ELECTRICAL EQUIPMENT NEEDS TO BE REMOVED DURING DEMO PROCESS. NOTE ELECTRICAL CONTRACTOR SMALL VISIT SITE AND VERIF EXISTING CONDITIONS. ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR REMOVING ALL ELECTRICAL DEVICE (LIGHT FIXTURES, RECEPTACLES, SWITCHES, ETC) AND EQUIPMENT INCLUDING CONDUIT $ WIRING BACK TO PANEL, TWAT IS NOT BEING REUSED. NOTHING SHALL BE ABANDONED IN PLACE. NOTE ALL WIRING SHALL BE IN CONDUIT (EMT OR RIGID). FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., (MAX. LENGTW, 6 FEET) . NO SX, ROMEX, ARMORED CABLE, ETC. ALLOWED. NOTE PRIOR TO BID CONTRACTOR SHALL OBTAIN A COPY OF THE "TENANT STORE DESIGN AND CONSTRUCTION MANUAL" FROM ARCH. OR MALL AND SHALL ADHERE TO APPLICABLE SECTIONS. L-20 L -18 1 AHU -2 1 (EXISTING)1 L-39,41 • =s_s� CU-1 1 ISTING)1 a w .1 H L NOTE: EXACT PL AN UNITS UNKN CONDITION AC r.:U -2 1 (EXISTING)1 22 L -40,42 10 FANLIGHT CAT. L -19 SL OWN IN OCATION OF CONDENSING . VERIFY LOCATION AND FIELD. VERIFY EXACT ROUTING AND LOCATION OF TERMINATIONS WITH ARCHITECT /OW FIRE ... EXTINGUISHER 2A -1OBC TO TELCO BACKBOA L -14 L -16 L -10 L -12 L-26 x LARGE TABLE SMALL TABLE NOTE: TELJDATA LINES SHALL BE INSTALLED BY E.G. INCLUDING ALL GABLE, BOXES, ETC. 0 L -1 ammo L-8 J -BOX FOR TV SUSP. W. 5.5. RODS (VERIFY EXACT LOCATION WITH TEN. PROJECT MANAGER) (2) LIGHTING CONTACTOR 5 I' 48 A.F.F. VERIFY LOCATI MOUNTING HEIGHT WITH TE Pi MANAGER (SEE SHEET E -3) 1 L-6 LARGE TABLE SMALL TABLE ■ 1I� - CONDUIT IN SLAB FOR FLOOR LIGHTING (TYP.) x CLG. OUTLET POWER PLAN SCALE : 1/4 "= 1/ -O" NOTE TENANT'S ELECTRICAL CONTRACTOR TO VERIFY THAT EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR NEW DESIGN. TENANT'S ELECTRICAL CONTRACTOR TO MAKE ALL CHANGES AT TENANT'S COST. NOTE EMPLOY LANDLORD FIRE ALARM CONTRACTOR FOR ALL CONNECTIONS TO LANDLORD FIRE ALARM SYSTEM. COORDINATE W I TW MALL OPERATIONS. THE FIRE ALARM DEVICES SHALL BE CONNECTED TO THE MALL'S GUARDIAN FIRE ALARM CONTROL PANEL CONNECTION DETAILS ARE ISSUED AT THE PRE- CONSTRUCTION MEETING. 601-1" III CLG.OUTLET NOTE: VERIFY ANY SAW CUTTING OR GORE DRILLING OF SLAB WITH ON SITE LANDLORD REP PRIOR TO STARTING WORK. ELECTRICAL FLOOR PLAN NOTES 1. COORDINATE FIXTURE JUNCTION BOX REQUIREMENTS W/ FIXTURE VENDOR. 2. FOR EXACT LOCATION OF MECHANICAL EQUIPMENT REFER TO MECHANICAL DRAWINGS. 5. USE *10 AWG-GU WIRING FOR (120V) CIRCUIT HOMERUNS EXCEEDING !COPT. OF ACTUAL LENGTH. ELECTRICAL CONTRACTOR SHALL INCREASE THE WIRE SIZE TO SUIT NECESSARY VOLTAGE DROP. VERIFY IN FIELD. ELECTRICAL VERIFICATION NOTE: PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CONTRACTOR SHALL CHECK NAMEPLATE DATA OF ALL HNA.C. EQUIPMENT, WATER HEATERS, AND OTHER EQUIPMENT, IN ORDER TO OBTAIN CORRECT WIRE SIZES, VOLTAGES, AND OVER - CURRENT PROTECTION. ADEQUATE SERVICE CAPACITY MUST BE PROVIDE. SUBJECT TO ELECTRICAL INSPECTION. FIDE COPY Permit No. 1rld� 00 0 Plan review approval is subject to Approval of construction . ments •'i } the violation of any adopted code or o of approved Field Copy and By Date: 3�I5 ^/Q. City Oflkikwil8 BUILDING DMSION r11, ,~`111,,1 s I and om not raze Receipt ed:s ArillI VINIMINitummenINIMMIMMINIV REVISIONS_ No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan suh,nitt -1 any may I i:iude additional plan . F`c { REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 0 9 2010 City of Tukwila BUILDING DIVISION �f2 w. lUPITISS it/Z.. NOTE: TENANT G.C. SHALL DETERMINE AVAILABLE FAULT CURRENT IN FIELD AND PROVDE PANELS AND CIRCUIT BREAKERS RATED ACCORDINGLY. RECEIVED FEB 04 2010 GENERAL NOTES: PERMIT CENTER 1. ELECTRICAL WORK SHALL CONFORM TO N.E.G. STATE Amp LOCALL JURISDICTIONAL ORDINANCES INCLUDING LANDLORD'S CONSTRUCTION GUIDELINES. 2. REGARDLESS OF THE EXISTING CIRCUITING, IT 15 THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROPERLY BALANCE ALL BRANCH PHASES OF THE ELECTRICAL PANEL TO WITHIN 105 OF EACH OTHER. 3. MAXIMUM LOAD OF BRANCH CIRCUIT SHALL BE 15% OF RATED CAPACITY. 4. ALL LIGHTING FIXTURE WORK SHALL BE WIRED PER ARTICLE 410 N.E.G. 5. PROVIDE CIRCUIT BREAKER LOCK -ON FOR THE FOLLOWING: - EMERGENCY/ EXIT 4 NIGHT LIGHTS - STOREFRONT SIGN- GA54 REGISTER- SECURITY AND TELEPHONE OUTLETS- TIME CLOCK- FIRE DETECTION SYSTEMS. 6. NOT USED 1. VERIFY EXISTING LIFE SAFETY SYSTEMS (FIRE/ SMOKE DETECTION) 15 IN GOOD WORKING ORDER AND MAKE ALL NECESSARY REPAIRS. 8. TRACK LIGHTING CIRCUITS ARE TO BE COMPUTED AT A MINIMUM OF 150 VA PER 2 LINEAR FEET OF LIGHTING TRACK PER N.E.C. 410 -102. 1. LAMP LOAD ON TRACK SHALL NOT EXCEED THE RATING OF TRACK CIRCUITS PER N.E.G. 410 -10113. £Ll&-OOB 1 REVISIONS BY 0) 10 0 cv 1 w H 2 Q co OG Q 0 M O N co 0 T 0 < -OT Q r J CO t0 r. aZNw � Z <-0 =¢ r`n O. u. W O z C PROJECT c0 c0 ® 4 r J w wZ I-oz® to v W O LLI mom,. zac� CO 11.1 CO j 0 F- = Z H DZ Q O W o0 W CD 1— Cl) CD 0. cc w 0 0. Date 1 -14-10 Scale 1/4" = 1' -0" Drawn B. MARTENEY Job Sheet E -1 Sheets / 0 - CONDUIT IN SLAB FOR FLOOR LIGHTING (TYP.) x CLG. OUTLET POWER PLAN SCALE : 1/4 "= 1/ -O" NOTE TENANT'S ELECTRICAL CONTRACTOR TO VERIFY THAT EXISTING ELECTRICAL SERVICE IS ADEQUATE FOR NEW DESIGN. TENANT'S ELECTRICAL CONTRACTOR TO MAKE ALL CHANGES AT TENANT'S COST. NOTE EMPLOY LANDLORD FIRE ALARM CONTRACTOR FOR ALL CONNECTIONS TO LANDLORD FIRE ALARM SYSTEM. COORDINATE W I TW MALL OPERATIONS. THE FIRE ALARM DEVICES SHALL BE CONNECTED TO THE MALL'S GUARDIAN FIRE ALARM CONTROL PANEL CONNECTION DETAILS ARE ISSUED AT THE PRE- CONSTRUCTION MEETING. 601-1" III CLG.OUTLET NOTE: VERIFY ANY SAW CUTTING OR GORE DRILLING OF SLAB WITH ON SITE LANDLORD REP PRIOR TO STARTING WORK. ELECTRICAL FLOOR PLAN NOTES 1. COORDINATE FIXTURE JUNCTION BOX REQUIREMENTS W/ FIXTURE VENDOR. 2. FOR EXACT LOCATION OF MECHANICAL EQUIPMENT REFER TO MECHANICAL DRAWINGS. 5. USE *10 AWG-GU WIRING FOR (120V) CIRCUIT HOMERUNS EXCEEDING !COPT. OF ACTUAL LENGTH. ELECTRICAL CONTRACTOR SHALL INCREASE THE WIRE SIZE TO SUIT NECESSARY VOLTAGE DROP. VERIFY IN FIELD. ELECTRICAL VERIFICATION NOTE: PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CONTRACTOR SHALL CHECK NAMEPLATE DATA OF ALL HNA.C. EQUIPMENT, WATER HEATERS, AND OTHER EQUIPMENT, IN ORDER TO OBTAIN CORRECT WIRE SIZES, VOLTAGES, AND OVER - CURRENT PROTECTION. ADEQUATE SERVICE CAPACITY MUST BE PROVIDE. SUBJECT TO ELECTRICAL INSPECTION. FIDE COPY Permit No. 1rld� 00 0 Plan review approval is subject to Approval of construction . ments •'i } the violation of any adopted code or o of approved Field Copy and By Date: 3�I5 ^/Q. City Oflkikwil8 BUILDING DMSION r11, ,~`111,,1 s I and om not raze Receipt ed:s ArillI VINIMINitummenINIMMIMMINIV REVISIONS_ No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan suh,nitt -1 any may I i:iude additional plan . F`c { REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 0 9 2010 City of Tukwila BUILDING DIVISION �f2 w. lUPITISS it/Z.. NOTE: TENANT G.C. SHALL DETERMINE AVAILABLE FAULT CURRENT IN FIELD AND PROVDE PANELS AND CIRCUIT BREAKERS RATED ACCORDINGLY. RECEIVED FEB 04 2010 GENERAL NOTES: PERMIT CENTER 1. ELECTRICAL WORK SHALL CONFORM TO N.E.G. STATE Amp LOCALL JURISDICTIONAL ORDINANCES INCLUDING LANDLORD'S CONSTRUCTION GUIDELINES. 2. REGARDLESS OF THE EXISTING CIRCUITING, IT 15 THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROPERLY BALANCE ALL BRANCH PHASES OF THE ELECTRICAL PANEL TO WITHIN 105 OF EACH OTHER. 3. MAXIMUM LOAD OF BRANCH CIRCUIT SHALL BE 15% OF RATED CAPACITY. 4. ALL LIGHTING FIXTURE WORK SHALL BE WIRED PER ARTICLE 410 N.E.G. 5. PROVIDE CIRCUIT BREAKER LOCK -ON FOR THE FOLLOWING: - EMERGENCY/ EXIT 4 NIGHT LIGHTS - STOREFRONT SIGN- GA54 REGISTER- SECURITY AND TELEPHONE OUTLETS- TIME CLOCK- FIRE DETECTION SYSTEMS. 6. NOT USED 1. VERIFY EXISTING LIFE SAFETY SYSTEMS (FIRE/ SMOKE DETECTION) 15 IN GOOD WORKING ORDER AND MAKE ALL NECESSARY REPAIRS. 8. TRACK LIGHTING CIRCUITS ARE TO BE COMPUTED AT A MINIMUM OF 150 VA PER 2 LINEAR FEET OF LIGHTING TRACK PER N.E.C. 410 -102. 1. LAMP LOAD ON TRACK SHALL NOT EXCEED THE RATING OF TRACK CIRCUITS PER N.E.G. 410 -10113. £Ll&-OOB 1 REVISIONS BY 0) 10 0 cv 1 w H 2 Q co OG Q 0 M O N co 0 T 0 < -OT Q r J CO t0 r. aZNw � Z <-0 =¢ r`n O. u. W O z C PROJECT c0 c0 ® 4 r J w wZ I-oz® to v W O LLI mom,. zac� CO 11.1 CO j 0 F- = Z H DZ Q O W o0 W CD 1— Cl) CD 0. cc w 0 0. Date 1 -14-10 Scale 1/4" = 1' -0" Drawn B. MARTENEY Job Sheet E -1 Sheets 142ceK_1211± CEILING: OPEN TO EXISTING METAL DECK ABOVE C +16,-10 1/4" A.F.F. NOTE: ALL EXITWAYS ARE TO BE ILLUMINATED TO AT LEAST ONE FOOT CANDLE AT THE FLOOR LEVEL. 5/8" TYPE 'X' GYP. BD. CEILING 0 +12'-O" APP. FINISH 4 PAINT (GU 15 L- LASER CUT ALUMINUM 'FALCON' kV CIRCULAR GRIND PATTERN ICON SET OFF WALL FACE 1 1/2" WITH WHITE NEON BEHIND LOCATED ON VERTICAL SOFFIT FACE BEI-IIND GLAZING (PROVIDE LOCAL MEANS OF DISCONNECT PER NEC) SIGN PROVIDE LOCAL MEANS OF DISCONNECT PER NEC 18" HIGH INDIVIDUAL HALO (REVERSE LIT) '51-11EK1-1' STOREFRONT SIGN MOUNTED ON TOP OF 4"X4" 55. 11.ILLION-CENTER IN OPENING. SIGN MANUF. TO PROVIDE SIGN SHOP DIAGS. TO LANDLORD FOR APPROV PRIOR TO FABRICATION. FURNISH 4 INSTALL OCCUPANCY SENSOR SWITCH LIGHTING PLAN SCALE : 1/4"= 1/-0" LIGHTING — CONTACTOR Q H EM LIGHTS (SWITCHED) AC BALLAST ■•••■■•11 EMERGENCY BALLAST AC BALLAST NIGHT LIGHTS (UNSWITCHED) 8 EM/NL BALLAST WIRING NOT TO SCALE FLAT SCREEN TV. SUSPENDED FIROM MALL STRUCTURE ABOVE 14/ 55 . PENDANT HANGERS. RUN POWER LINE THRU PENDANT HANGER. LOCATE J-EOX 0 STRUCT. ABOVE- CENTERED ON OPENING BOTTOM 0 +=ILO" A.F.F. NOTE ELECTRICAL CONTRACTOR S1-IALL VISIT SITE AND VERI EXISTING CONDITIONS. ELECTRICAL CONTRACTOR 15 RESPON5IE3LE FOR REMOVING ALL ELECTRICAL DEVICE (LIGWT FIXTURES, RECEPTACLES, SIAIITC1-IES, ETC) AND EQUIPMENT INCLUDING CONDUIT 4 NIRNG BACK TO PANEL, TWAT 15 NOT BEING REUSED. NOTWING SWALL BE ABANDONED IN PLACE NOTE: EXIT, EMERGENCY AND NIGHTLIGHTING FIXTURES SHALL BE CONNECTED TO UNSWITCHED CIRCUITS. NOTE: SALES AREA LIGHTING SHALL BE CONTROLLED BY TWO LIGHTING CONTACTORS (C1 & C2) NOTE: GENERAL CONTRACTOR TO PROVIDE ANTI-SWAY BRACING FOR ALL SUSPENDED L I GHT F I XTURES AND DUCTING NOTE: MODIFICATIONS TO THE FIRE SPRINKLER SYSTEM MUST BE APPROVED BY THE FIRE PREVENTION DIVISION AND WILL REQUIRE A SEPARATE PERMIT. L-13 NOTE: STOREFRONT SIGN(5) AND 514014 WINDOW DOWNLIGHTS SHALL BE ON TIMECLOCK (CKTS. L-1, L-21, $ L-21) agammesers' LASER GUT ALUMINUM 'FALCON!' Hi CIRCULAR GRIND PATTERN ICON SET OFF WALL FACE 1 1/2" 141T1-1 141-11TE NEON BEHIND LOCATED ON VERTICAL SOFFIT FACE BEI-IIND GLAZING (PROVIDE LOCAL MEANS OF DISCONNECT PER NEC) REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 0 9 2010 City of Tukwila BUILDING DIVISION LIGHT FIXTURE SCHEDULE DESCRIPTION MANUFACTURER "LOW-BAY" METAL HALIDE SUSPENDED LIGHT FIXTURE EMERGENCY LIGHT "LOW-BAY" METAL 4-1ALIDE SUSPENDED LIGHT FIXTURE WITI4 QUARTZ EMERGENCY AMP PACKAGE. DUR.A-GUARD 0150M14A C14B 16 15014 METAL HALIDE kV 1400K 4 36" CORD 14/ LAMP DURA-GUARD *150114A 04-1516 15014 METAL HALIDE IA/ 1400K It 36" CORD kV LAMP REMARKS CONTACT: JERRY GILMAN AMERICAN WHOLESALE LIGHTING 510-252-1088 EXT 215 FAX 510-252-1010 SUSPENDED/ MTD WITH AIRCRAFT CABLE DESCRIPTION MANUFACTURES REMARKS CONTACT: JERRY GILMAN AMERICAN WHOLESALE IGHTING 510-252-1088 EXT 215 g FAX 510-252-1010 SUSPENDED/ MTD WITH AIRCRAFT CABLE INTERNALLY ILLUM. EXIT SIGN ?V 410 MIN. BATTERY PACK- MOUNT SO AS NORA NX600 GREEN NOT TO BE VISIBLE FROM MALL 001110N AREA TRACK MOUNTED LIGHT V V V 2', 4', 6' 4 8' TRACKS PLC LIGHTING TR402 EXN NORA TRACK TRACKS ARE 2', 4', 6' 4 8' TRACKS TO BE ON PENDANTS- BTM 0 +12'-0" RECESSED FLUORESCENT DOWN LIGHT 0 SURFACE MOUNTED SINGLE LAMP T-8 FLUOR. STRIPLIGI-IT DAYBRITE *N-130-T8-12C RECESSED IN ARCH, COVE. NsR_3 smss OR EQUAL 24"/36" LONG LAMPS AS REQ'D. TO FIT WITHIN 48" OF WALL NOT USED NORA N141=8128 HOUSING QUAD 18/821 PENDANT LIGHT WITH 514ADE ALFA OTT21-FT13- G15-EXN-MR16 0 12"X48" SURFACE MOUNTED FLUOR. 14/ CLR. PRISMATIC LENSES CRECSENT 51^1131.. 40E5B5U F4OCW RECEIVED FEB 0 4 2010 PERMIT CENTER 48' LONG CHAIN I-R.NG SINGLE TUBE FLUORESCENT LIGHT FIXTURE BRILL I ANT L I GHT ING 120V WWI TE POWDER 1 LAMP 48" 14/ INDUST. COATED FINISH HANGERS 24" LONG UNDER COUNTER LIGHT JESCO SP-24-6400K INCLUDES LAMP (2) HEAD EMERGENCY LIGHT WITH 10 MINUTE BATTERY PACK NORA SF-800 COMBINATION LED $ NORA NEX-104- 151ERGENCY-TOP GREEN LED/GREEN ELEGTRIGAL NOTES B SECIICATION5 GENEIUL CONDITIONS :, 1. QUOTATIONS: ALL CONDITIONS AND REQUIREMENTS FOUND UNDER 'GENERAL CONDITIONS' AND 'SPECIAL CONDITIONS' AS WELL AS INFORMATION FOUND WITHIN THIS ET OF DRAWINGS SHALL FORM THE BASIS OF DEVELOPING A BID, TWEREFORE IT 15 114E RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REVIEW ALL. SHEETS. THESE DRAWINGS ARE FOR SCHEMATIC PURPOSES ONLY. THE CONTRACTOR SMALL INCLUDE IN 1415 BID ALL COSTS TO MAKE ALL NECESSARY ADJUSTMENTS TO PROVIDE A COMPLETE INSTALLATION PER CODE REQUIREMENTS AND LANDLORD SPECIFICATIONS AS CONTEMPLATED BY THESE DRAWINGS. THE QUOTATION SMALL INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, PERMITS AND FEES, AND ANY OTHER INCIDENTAL COSTS NECESSARY TO COMPLETE THE WORK AS SPECIFIED ON TWEE PLANS. PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SMALL INSPECT THE SITE, AND INCLUDE IN MIS FINAL PRICE ALL ADJUSTMENTS AND CHANGES REQUIRED BY EXISTING CONDITIONS. 2. INSURANCE: THE ELECTRICAL CONTRACTOR SMALL INCLUDE N WIS PRICE THE COST OF ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE. 3. SUBSTITUTIONS: UNLESS REQUESTS FOR SUBSTITUTIONS ARE RECEIVED IN WRITING ALL BID PROCESS WILL BE FOR THE EQUIPMENT AS SPECIFIED ON THESE DRAWINGS. A REQUEST FOR SUBSTITUTION, IN ORDER TO BE CONSIDERED, MUST INCLUDE THE FOLLOWING INFORMATION - PERFORMANCE DATA, TEST RESULTS, AND OTHER PROOF THAT THE SUBMITTED ITEM IS OF EQUAL QUALITY. 4. WORKMANSHIP: ENTIRE INSTALLATION SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR 114 A FIRST CLASS WORKMANSHIP -LIKE MANNER, THE COMPLETED SYSTEM SMALL BE FULLY OPERATIVE AND BALANCED ACROSS ALL PHASES. ALSO, CONTRACTOR SMALL GUARANTEE ALL MATERIALS AND WORKMANSHIP TO BE FREE FROM DEFECTS FOR A PERIOD OF (ONE) 1 YEAR FROM THE DATE OF FINAL ACCEPTANCE. CORRECTION OF ANY DEFECTS 514ALL BE COMPLETED 19411 14 NO ADDITIONAL CHARGE AND SHALL INCLUDE OR MATERIALS DAMAGED BY SAID DEFECTS. 5. PERMITS, TESTS AND INSPECTIONS: ELECTRICAL CONTRACTOR SMALL: A. APPLY FOR, SECURE AND PAY FOR ALL REQUIRED PERMITS, LICENSES AND FEES. B. APPLY FOR, SECURE AND PAY FOR ALL REQUIRED TESTS AND INSPECTION FOR CODE COMPLIANCE. 6.GODES: ENTIRE INSTALLATION SMALL CONFORM TO NEC., STATE AND LOCAL ORDINANCES HAVING JURISDICTION. ALSO, INSTALLATION MUST MEET ALL LANDLORD REQT•RS. 1. GLEAN -UP: CONTRACTOR SMALL REMOVE ALL SURPLUS MATERIALS (EXCEPT FOR EXTRA LAMPS) FROM THE PREMISES AT THE COMPLETION OF JO5. GENERAL CONTRACTOR SMALL NOTIFY G•G CONSTRUCTION DEPARTrENT FOR DISPOSITION SHOULD ANY EXCESS TENANT SUPPLIED MATERIALS REMAIN. 8. TEMPORARY POWER: UNLESS LANDLORD PROVIDED, ELECTRICAL CONTRACTOR SMALL PROVIDE TEMPORARY ELEGTRIGAL SERVICE TO THE PREMISES FOR THE PURPOSE OF GENERAL ILLUMINATION AS WELL AS TO POWER SUFFICIENTLY, ANY EQUIPMENT REQUIRED TO CONSTRUCT 11415 STORE. ELECTRICAL CONTRACTOR SMALL DISCONNECT AND REMOVE TEMPORARY POWER WHEN IT IS OPERATING AND APPROVED. q. COORDINATION OF TRADES: ELECTRICAL CONTRACTOR SMALL VISIT THE SITE AND SMALL REVIEW STRUCTURAL, PLUMBING AND HVAC PLANS AND SHALL ADJUST THEIR WORK TO CONFORM TO ALL CONDITIONS FOUND AND /OR SHOWN ON THE PLANS OR AS MAY BE DIRECTED IN THE FIELD BY THE OWNER'S REPRESENTATIVE. ELECTRICAL CONTRACTOR SMALL ALSO COORDINATE WITH ALL OT1 -TER TRADES TO PREVENT DUPLICATION OF WORK AND TO FACILITATE THE COORDINATION OF THE JOB. IOLANDLORD REQUIREMENTS: ALL WORK SHALL BE DONE IN STRICT COMPLIANCE WITH THE LANDLORDS REQUIREMENTS AND ANY WORK SHALL NOT BE STARTED WITHOUT 114! LANDLORDS APPROVAL. NOTCHING OR DRILLING OF HOLES IN LANDLORD'S STRUCTURE MUST BE FRE- APPROVED BY THE LANDLORDS REPRESENTATIVE. PIarn ALAaT'I SYST9"I NOTES IF REQUIRED BY LANDLORD, FIRE OFFICIALS OR OTHER AUTHORITIES IN JURISDICTION, TENANT ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE FIRE/SMOKE DETECTION AND ALARM SIGNALLING SYSTEM, DEIGNED AND INSTALLED IN TOTAL CONFORMANCE WITH ALL APPLICABLE CODES. SYSTEM SMALL INCLUDE, BUT 15 NOT NECESSARILY LIMITED TO, TWE FOLLOWING: A) MANUAL PULL STATIONS AT ALL EXIT DOORS. B) AREA SMOKE DETECTORS. G) AUDIBLE AND VISUAL ALARMS. D) SPRINKLER FLOW AND VALVE TROUBLE ALARMS. E) DUCT INSERTION SMOKE DETECTORS P) ZONE ADAPTER MODULE (ZAM) FOR TIE-IN TO MALL CENTRAL ALARM SYSTEM. WHERE THE MALL IS EQUIPPED WITH A CENTRAL FIRE ALARM SYSTEM, TENANT'S ALARM SYSTEM SHALL BE OF THE SAME MANUFACTURE AND TYPE AND SHALL BE PROVIDED WITH ALL REQUIRED INTERFACE DEVICES. PETWOO AND stari?IALS: 1. ALL MATERIALS SHALL BE NEW UNLESS OTHERWISE NOTED ON THE DRAWINGS AND SMALL BEAR TWE UNDERWRITERS AND UNION LABELS AS APPLICABLE. 2. MINIMUM SITE FOR ALL PULL BOXES SMALL BE 4' TRADE. 3. MINIMUM WIRE SIZE SMALL BE 12 AWG 4. ALL FLUORESCENT LIGHTING FIXTURES SHALL HAVE 141G4 POWER FACTOR BALLASTS. 5. TIME SWITCHES SMALL BE PARAGON, AND /OR YORK WITH RATING AND POLES AS REQUIRED. 6. ALL WIRES SHALL BE IN CONDUIT CONSTRUCTED EITHER OF GALVANIZED STEEL. RIGID HEAVY METAL WALLED, OR ELECTRIC - METALLIC TUBING (EMT) WITH WATERTIGHT FITTINGS. FLEXIBLE CONDUIT MAT BE USED IP APPROVED BY LOCAL CODES AND PERMITTED BY LANDLORD. UNDER NO CIRCUMSTANCES IS RONEX TO BE USED. CONDUIT SHALL CONFORM TO THE FOLLOWING GUIDELINES: A. CONCEALED IN CEILINGS OR PARTITIONS - EMT B. CONCEALED IN CONCRETE SLAB - EMT G. UNDERGROUND OR BELOW SLABS - IMG OR RIGID GALVANIZED STEEL. 1. EXCEPT WERE OTHERWISE NOTED, WIRE SHALL BE COPPER 600 VOLT, INSULATED TYPE THWN. BRANCH CIRCUIT WORK WITH SIZES LARGER THAN NO. 4 SHALL BE TYPE THW. 8. OUTLET BOXES SHALL BE PRESSED STEEL, PROPER TYPE SIZE PER BUILDING CONDITIONS, FOR ALL LIGHTING, SWITCHES, TIME CLOCKS, RELAYS, AND RECEPTACLES. q. NYLON PULL WIRES SMALL BE INSTALLED IN EMPTY CONDUIT AS REQUIRED. 10 WIRING DEVICES SMALL BE AS FOLLOWS: A. LIGHT SWITCHES - 20 AMP MFG. HUBBEL * 1221 B. DUPLEX - 20 AMP MPG. HUBBEL 0 5252 ALL SWITCHES AND OUTLETS SMALL HAVE COVER PLATES AS APPROPRIATE OF BAKELITE UNILINE DESIGN, COLOR BLACK. THE OUTLETS FOR LOCAL SWITCHES SHALL BE INSTALLED ADJACENT TO 1145 TRIM ON THE STRIKING SIDE OF DOOR REGARDLESS OF THE LOCATION INDICATED ON THESE PLANS II. NEW LIGHTING PANELBOARDS SHALL BE THREE PHASE, FOUR WIRE DISTRIBUTION TYPE, ALL WREAKERS SMALL BE BOLT DOWN, THERMAL MAGNETIC TYPE, APPROVED FOR SWITCH DUTY AND MARKED 'SWD'. CIRCUIT BREAKERS AND PANELBOARDS SMALL BE MFG. BY 'SQUARE -D' ONLY (NO SUBSTITUTIONS) REGARDLESS OF THE CIRCUITING INDICATED ON THESE PLANS, IT IS THE RESPONSIBILITY OF 1145 ELECTRICAL CONTRACTOR TO PROPERLY BALANCE ALL BRANCH PHASES TO WITHIN 10% OF EACH OTHER. ELEGTRIGAL CONTRACTOR IS ALSO TO PROVIDE A TYPEWRITTEN PANEL SCHEDULE FOR EACH DISTRIBUTION PANEL AS WELL AS PROVIDE AND INSTALL 'LOCK DOGS' ON THE FOLLOWING CIRCUITS: EMERGENCY LIGHTING, EXIT LIGHTS, ROLL-UP GRILLE, NIGHT LIGHTS, GASH REGISTER OUTLET, SECURITY SYSTEM, AND ANY OTHER CIRCUIT 4.5 DESIGNATED ON THE PLANS. 12. SAFETY SWITCHES: SAFETY SWITCHES SMALL BE PROVIDED AS SHOWN OR AS REQUESTED. THEY SMALL BE HEAVY DUTY, 1' ETAL ENCASED EXTERNALLY OPERATED OF SUCH TYPE AND SIZE NECESSARY TO PROTECT TI4E LOAD FOR 101141G14 THEY ARE INTENDED. 1145 OPERATING MECHANISM SHALL BE DESIGNED TO BE LOCKED IN EITHER TWE'ON' OR 'OFF' POSITION. ANY SAFETY SWITCH REQURED TO BE WATERPROOF SMALL CONFORM TO NEMA 111, RAINIEST. 15. DRY TYPE : ELECTRICAL CONTRACTOR SHALL RJRNISH AND INSTALL A DRY TYPE AIR COOLED TRANSFORMER AS SPECIFIED ON TI4E PLANS. THE TRAN.SFORMER SHALL WAVE VIBRATION DAMPERS, GLASS H INSULATION, AND THE WIRING TEMPERATURE RISE SHALL NOT EXCEED 150 C. THE MAXIMUM ACCEPTABLE NOISE SMALL NOT EXCEED 42 dB. 14. ALL MAIN AND BRANCH WIRING, BUS BARS, ETC. SHALL BE SOLID COPPER. (ALUMINUM OR COPPER PLATED ALUMINUM WILL BE REJECTED). 15. MAXIMUM LOAD OF BRANCH CIRCUITS SMALL BE 15% OF RATED CAPACITY. 16. ALL LIGHTING FIXTURES SI4ALL BE WIRED PER ARTICLE 410 OF N.E.C. 11. BONDING SMALL BE PROVIDED AS PER ARTICLE 250-12 OF 11H5 N.E.C. WHERE NECESSARY TO ENSURE ELECTRICAL CONTINUITY AND THE CAPACITY TO CONDUCT SAFELY THE FAULT CURRENT LIKELY TO BE IMPOSED. 18. GROUNDING TYPE BUSHING SHALL BE USED AS REQUIRED. ALL MAJOR COMPONENTS NOT CARRYING CURRENT 514ALL BE GROUNDED, INCLUDING BUT LIMITED TO: - SECONDARY FEEDERS AND EQUIPMENT ENCLOSURES - JUNCTION BOXES, WIRING TROUGHS - OUTLET BOXES, AND HOUSINGS Iq. ELEGTRIGAL CONTRACTOR 514ALL PROVIDE AND CONNECT TI-15 HIGH VOLTAGE LINES TO THE HVAG EQUIPMENT. HVAC CONTRACTOR SI4ALL CONNECT LOW VOLTAGE LINES TO TH5 THERMOSTAT(S) AND OTHER LOW VOLTAGE HVAG EQUIPMENT AS REQUIRED. ELECTRICAL CONTRACTOR SHALL RUN ALL WIRING INCLUDING LOW VOLTAGE WIRING AS REQUIRED TO MAKE READY FOR FINAL CONNECTION OF LOW VOLTAGE DEVICES BY I4VAC CONTRACTOR. HVAC CONTRACTOR WILL PROVIDE WIRING DIAGRAMS AND INSTRUCTIONS AS NEEDED TO 1145 ELECTRICAL CONTRACTOR. 20. ELEGTRIGAL CONTRACTOR SHALL MAKE 1145 FOLLOWING CONNECTIONS ASSOCIATED WITH THE ROLL UP GRILLE: BRANCH CIRCUIT TO MOTOR, AND CIRCUIT WIRING OF INTERLOCK CONTROL DEVICES. ROLL UP GRILLE MFR. IS TO PROVIDE ALL REQUIRED WIRING DIAGRAMS. 21. MUSIC SYSTEM EQUIPMENT IS FURNISHED BY TENANT AND INSTALLED BY TENANT'S ELECTRICAL CONTRACTOR. 22. SIGN CONTRACTOR SMALL INSTALL SIGN. ELECTRICAL CONTRACTOR TO PROVIDE FINAL CONNECTION OF SIGNS (FROM SIGN 'J' BOX) SIGN CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING OPERATIONS OF SIGN AFTER FINAL CONNECTION 23. ELECTRICAL CONTRACTOR SMALL VERIFY EXACT ELECTRICAL REQUIREMENTS AND EXTENT OF WORK WITH LOCAL PHONE COMPANY FOR TELEPHONE SYSTEM INSTALLATION. 24. IT IS THE RESPONSIBILITY OF T145 ELECTRICAL CONTRACTOR TO PROVIDE THE TENANT AND TI-15 LANDLORD 141114 1A5 BUILT' PLANS. 25. STOREFRONT SIGN AND SOFFIT LIGHTING, IF REQUIRED, ARE TO BE CONNECTED TO A TIME CLOCK. 26. SECURITY OUTLET SMALL BE INSTALLED ABOVE CEILING AS INDICATED ON THE POWER PLAN. SPECIAL CONDITIONS: INSULATED /ISOLATED GROUND SYSTEM REQUIRE" ENTS FOR GA5N REGISTER OUTLET. 1. CASH REGISTER REQUIRES AN ISOLATED OR DEDICATED 20 AMPERE, 120 VOLT SINGLE PHASE CIRCUIT. (A REGISTER CANNOT SHARE A CIRCUIT WITH ANY OTHER INDUCTIVE LOADS). ALL THREE WIRES, GROUND, NEUTRAL, AND POWER, MJST BE RUN TO CIRCUIT BREAKER BOX VIA CONDUIT TWAT CONTAINS ONLY THESE WIRES. GROUND AND NEUTRAL MUST BE RUN SEPARATELY AND SMALL BE CONNECTED PER LOCAL APPLICABLE ELECTRICAL CODE. GROUND WIRE SMALL BE RUN TO GROUND POINT OF THE DEMISED PREMISES (A WATER PIPE) 2. GASH REGISTER OUTLET SMALL BE OF THE TYPE THAT DOES NOT WAVE THE GROUND TERMINAL CONNECTED TO 1145 RECEPTACLE MOUNTING BRACKET, (EQUIVALENT TO HUBBEL * 1G5262 DUPLEX OR HUBBEL * 1G5251 SINGLE). A SPECIAL INSULATED TERMINAL BLOCK IN DISTRIBUTION BOX, AND 1145 USE OF INSULATED GROUND WIRE FROM THE RECEPTACLES UNDER THE CASW/WRAP DESK TO 1145 DISTRIBUTION BOX 4 FROM THE DISTRIBUTION BOX 1145 STORE ENTRANCE BOX. UNDER NO CIRCUMSTANCE SMALL CONDUIT OR DUCT BE USED AS A GROUND, OR P.V.C. CONDUIT BE USED. OUTLET TO BE COLOR CODED FOR DEDICATED USE. 5. 1145 GASH REGISTER 15 SUPPLIED WITH A THREE -PRONG PLUG. 1145 USE OP ISOLATORS OR CONVERSION PLUGS TOTALLY DEFEAT 1145 PURPOSE OF 1145 GROUND. ELECTRICAL CONTRACTOR SMALL NOT USE CONVERSION PLUGS N ANY INSTALLATION OF ELECTRONIC GA514 REGISTERS. 4. POWER AND GROUND SYSTEM INSTALLATION SMALL CONFORM TO ALL WIRING DIAGRAMS AND REFERENCE SHEETS FURNISHED BY CASH REGISTER MANUFACTURER. 5. ELECTRICAL CONTRACTOR SMALL OBTAIN FROM 7445 TENANT ALL REQUIRED INFORMATION PERTAINING TO THE CASH REGISTER SYSTEM POWER WIRE AND WIRING INSTALLATION. ALL ELECTRICAL EQUIPMENT SHALL BE MANUFACTURED BY "SQUARE-D". NO SUBSTITUTES. NEMA 1-- ENCLOSURE CONTACTOR - CONTROL CIRCUIT H N TYPICAL MOMENTARY CONTACT WALL SWITCH TIME r: L_DirtS aaaaa COMMON -D CLOSE _D[2.F.,EN ODD 0 0 SPARE 111111) LOAD SIDE TYPICAL TORK ELECTROMECHANICAL 1800 SERIES MOMENTARY CONTACT TIME SWITCH FOR MECHANICALLY HELD CONTACTORS OR APPROVED EQUAL LINE SIDE - TYPICAL UGHTING CONTACTOR AS SCHEDULED. TYPICAL LIGHTING CONTROLS 50% LIGHTING 50% LIGHTING ,a. 'b' SCALE: NONE MASTER LIGHTING SWITCHBANK SCALE: NONE DUCT HOUSING AND BASE WITH PHOTOELECTRIC DETECTOR SIMPLEX #2098 -9201 120 V. CONTROL CIRCUIT TO PANEL 120/24 V. TRANSFORMER LOCATED IN DETECTOR HOUSING. REMOTE RESET STATION SIMPLEX #2750 -9003 SR SIMPLEX #2098 -9739 SUPERVISORY RELAY FOR SECURITY COMPANY MONITORING. MOUNT WITH HORN IN DEEP BOX. 4" SQUARE SEMI -FLUSH 120 VAC HORN SIMPLEX 32901 -9551 POWER 0 0 NORMAL ler -r ALARM TEST 1/2" CONDUIT. (NUMBER OF WIRES ACCORDING TO MANUFACTURER) NOTE: ELECTRICAL CONTRACTOR SHALL COORDINATE A/C SHUT DOWN WITH MECHANICAL CONTRACTOR. COORDINATE EXACT LOCATION OF TEST AND RESET SWITCHES, AND HORN, WITH THE OWNER AND /OR ARCH. REMOTE TEST STATION POWER L.E.D. ALARM INDICATOR. 1- SIMPLEX #2098 -9805 DUCT DETECTOR DETAIL SCALE: NONE CHECK WITH MALL REPRESENTATIVE FOR APPLICATION (4) #3/O, 2 "C (EXISTING, V.I.F.) EXISTING FUSED DISC. (V.I.F.) 1- r - -i - -1 1 -i 200A 1 J 150AF ■ ■ - -r - -J LEASE LINE (4) #3/0, 2 "C (EXISTING, V.I.F.) • ELECTRIC LOAD SUMMARY D ON CC IECT KW VOLT PHASE FACTOR KW L •fl1l >t 8.2 120 1.25 10.3 Pol E D�CF1i'flON cu. NO RECEPTACLES 5.0 120 1.0 < 10KW 0.5 REMAINING KW 5.0 81011118 / NON 2.4 120 1.25 3.0 A 1200 20 12 1 WATTS:! HEATER 1.8 120 1.0 1.8 M.H. DOWNUGHTS 1.2 120 1.25 1.5 8W °m em 18 EXHAUST 1 VENTILATION • 1 120 1.0 .1 4 5 SPARE HVAC 24.0 230 1.0 24.0 540 20 12 1 RECEPTACLES (3) TOTAL - 42.7 CATEGORIES COMPRESSOR IN SYSTEM (200VA PER FOOT OF LIGHTING KVA. AmpERAGE 45.7 OF THE TWO MOTOR OR ONE UNIT. REQUIREMENT ACTUAL SHOW WINDOW - logium Fes. SHOW * USE GREATER VALUE ** 125% OF THE LARGEST APPLIED ONLY ON * ** N.E.C. ARTICLE 220-12 WINDOW) MINUS NE.C, DMNI) KVA x 1000 SYSTEM VOLTAGE x 0 45.7 x 1000 AMPS = 127.0 208 8 ,13 360 FEOIJFiED 12 ADDMOIVAL NOTES THE TENANT'S GENERAL CONTRACTOR AND /OR HIS ELECTRICAL SUBCONTRACTOR IS TO VERIFY ALL EQUIPMENT SPECIFICATIONS AND REQUIREMENTS WITH THE TENANT OR THE TENANT'S CONSTRUCTION REPRESENTATIVE PRIOR TO START OF CONSTRUCTION. THIS CONTRACTOR TO VERIFY AMPERAGE AND VOLTAGE SPECIFICATIONS AND REQUIREMENTS TO SERVICE PANEL SPECIFICATION WITH THE ELECTRICAL SUBCONTRACTOR IN COORDINATION WITH EQUIPMENT SPECIFICATIONS FOR EQUIPMENT SUPPLIED BY THE TENANT, THE CONTRACTORS OR OTHER SOURCES AS SPECIFIED BY THE ARCHITECT AS A DOUBLE CHECK TO ASCERTAIN PROPER INSTALLATION OF EQUIPMENT AT THE CORRECT VOLTAGE / AMPERAGE. BOTH THE TENANT'S AND THE LANDLORD'S GENERAL CONTRACTORS AND ALL SUBCONTRACTORS WORKING ON THIS PROJECT ARE RESPONSIBLE FOR CONTACTING THE LANDLORD AND /OR THE PUBLIC UTILITY COMPANIES WHICHEVER IS APPLICABLE) SUPPLYING UTILITIES TO THE AREA WHERE THE PROJECT IS LOCATED, IN ORDER TO VERIFY LOCATIONS OF UTILITIES, UNDERGROUND OR OVERHEAD, AND SECURE THE PROPER PROCEDURES WHILE WORKING ADJACENT TO, ABOVE OR NEAR SUCH UTILITIES TO AVOID ANY PROBLEMS WITH EXPLOSIONS, DISCONNECTION'S, REMOVALS, ETC. (N�j /0, 2 "C H150A L (NEW) C -C INTERCEPT EXISTING FEEDERS AND EXTEND TO NEW PANEL LOCATION (VERIFY EXACT DISTANCE IN FIELD) (2) LIGHTING CONTACTORS, 8 POLE EACH ASCO 917 STANDARD NEMA WITH MECHANICALLY HELD ASCO 173 P REC'D SWITCHES MTD. +48" A.F.F. 3b' -120/208V, 3P, 4W PANEL TIME CLOCK (24 HR.) CALENDAR TYPE (4 POLE, 40 AMP) ELECTRIC PANELBOARD SCHEDULE PAIEBOARD L (NEW) PAIL. TYPE NQOD NEMA TYPE ENCLOSURE 1 vourAce 120/208 piiikeE 3 WilE 4 MANS 150A MCB BUR RATING 225A MO(W t1Q SURFACE OP?IONS W/ I.G. BUS AIC RATING 10,000 NOTE CONNECT BLADE SIGN AND STOREFRONT SIGN TO THE SAME CIRCUIT i LANDLORD'S EXISTING 120/208V, 30, 4W, SERVICE 0 NOTE: ALL CONDUCTORS SIZED FOR 75 DEGREE C. NOTE: CONTRACTOR TO SUPPLY AND INSTALL ALL DISCONNECTS AND FUSES AS REQUIRED. ELECTRICAL RISER DIAGRAM NOT TO SCALE 1 NOTE: ELECTRICAL CONTRACTOR SHALL VISIT SITE, NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO BID. IF ANY EXISTING EQUIPMENT IS TO BE REUSED, IT WILL BE REQUIRED TO SATISFY THE REQUIREMENTS OF THE CURRENT NEC WITH REGARDS TO RATING, IDENTIFICATION, USE, WIRE BENDING SPACE, ETC. AS IF THEY WERE NEW. NOTE ELECTRICAL CONTRACTOR 5W -TALL VISIT SITE AND VEI2I - EXISTING CONDITIONS. ELEGTRIGAL CONTRACTOR 15 RESPONSIBLE FOR IRE" LOVING ALL ELECTRICAL DEVICE- (L I GI-IT FIXTURES, RECEPTACLES, SW I TC1 -TES, ETC) AND EQUIPMENT INCLUDING CONDUIT 4 NIRING BACK TO PANEL, THAT 15 NOT BEING REUSED. NOT! -LING SMALL BE ABANDONED IN PLACE. E L E C T R I C A L V E R I F I C A T I O N N O T E : PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CONTRACTOR SHALL CHECK NAMEPLATE DATA OF ALL H.V.A.C. EQUIPMENT, WATER HEATERS, AND OTHER EQUIPMENT, IN ORDER TO OBTAIN CORRECT WIRE SIZES, VOLTAGES, AND OVER - CURRENT PROTECTION. ADEQUATE SERVICE CAPACITY MUST BE PROVIDED. SUBJECT TO ELECTRICAL INSPECTION. ELECTRICAL RISER DIAGRAM NOTES: 1. TENANT'S ELECTRICAL CONTRACTOR SHALL COLOR CODE FEEDER CONDUCTORS AT TENANT METER CENTER TO DESIGNATE PHASE NEUTRAL AND GROUND. 2. TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VER /FY EXACT K.A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT. J. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10X ( +) BETWEEN PHASES: A/B, B /C, A/C REGARDLESS OF CIRCU/17NG INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. f7ELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 6. PANELBOARD(S) TO HAVE BOLT -ON BREAKERS. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 0 9 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 4 2010 PERMIT CENTER DEBTION POLE WWE WATTS F'PIABE WATTB BFEAKBI Pol E D�CF1i'flON cu. NO 1 Q FLOOR UGHTING 1 12 20 260 A 1200 20 12 1 S/W RECEPTACLES 2 3 Q M.H. DOWNUGHTS 1 12 20 1000 B 20 12 1 SPARE 4 5 SPARE 1 12 20 C 540 20 12 1 RECEPTACLES (3) 6 7 TC STOREFRONT DOWNUGHTS 1 12 20 540 A 360 20 12 1 CASH REG. I.G. LO 8 9 © TRACK 1 12 20 1650 B 1080 20 12 1 RECEPTACLES (3) C/W LO 10 11 O CASHWRAP PENDANTS 1 12 20 135 C 360 20 12 1 N OUTLET 12 13 © TRACK 1 12 20 975 A 1080 20 12 1 RECEPTACLES (3) DESK 14 15 © STOCK FL 1 12 20 385 B 1800 20 12 1 WATER HEATER LO 16 17 Oa STOCK FL 1 12 20 385 C 360 20 12 1 SECURITY LO 18 19 TOILET FAN/LT/REC. 1 12 20 340 A 360 20 12 1 TELCO LO 20 21 TC STOREFRONT SIGN 1 12 20 1200 B 280 20 12 1 REC./LIGHT- -ROOF 22 23 LO NL/EMERG./EXIT 1 12 20 380 C . 20 12 1 SPARE 24 25 ® M.H. DOWNUGHTS 1 12 20 750 A 540 20 12 1 RECEPTACLES (3) 26 27 TC ILLUMINATED LOGOS 1 12 20 1200 B 28 29 Oa COVE LIGHTING 1 12 20 420 C 30 31 © M.H. DOWNUGHTS 1 12 20 1000 A 32 33 B 34 37 HACR AHU -1 (230V) FANS & HEATER 2 8 50 6000 C *3000 40 8 2 ACLU -1 (230V) * NON - COINCIDENT HACR 38 38 6000 A *3000 39 _.�........_,. HACK AHU -2 (230V) FANS & HEATER 2 8 50 6000 B *3000 40 8 2 ACLU -2 (230V) * NON - COINCIDENT HACR 40 42 6000 C *3000 ALL PHASES TO BE BALANCED TO WTTF<1 10X HACR- HEATING, A R CONDITIONING RATED A- 13,405 W LO - CIRCUITS ON HANDLE LOCK -OFF DEVICE. B- 14,595 W /C- CIRCUITS ON TIME CLOCK. - CIRCUITS ON LIGHTING CONTACTOR. C- 14,580 W a,b,c,d - SWITCHES ON LIGHTING CONTACTOR. TOTAL CONNECTED LOAD ■ 42,580 W - 118.3 AMPS CONNECT BLADE SIGN AND STOREFRONT SIGN TO THE SAME CIRCUIT i LANDLORD'S EXISTING 120/208V, 30, 4W, SERVICE 0 NOTE: ALL CONDUCTORS SIZED FOR 75 DEGREE C. NOTE: CONTRACTOR TO SUPPLY AND INSTALL ALL DISCONNECTS AND FUSES AS REQUIRED. ELECTRICAL RISER DIAGRAM NOT TO SCALE 1 NOTE: ELECTRICAL CONTRACTOR SHALL VISIT SITE, NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO BID. IF ANY EXISTING EQUIPMENT IS TO BE REUSED, IT WILL BE REQUIRED TO SATISFY THE REQUIREMENTS OF THE CURRENT NEC WITH REGARDS TO RATING, IDENTIFICATION, USE, WIRE BENDING SPACE, ETC. AS IF THEY WERE NEW. NOTE ELECTRICAL CONTRACTOR 5W -TALL VISIT SITE AND VEI2I - EXISTING CONDITIONS. ELEGTRIGAL CONTRACTOR 15 RESPONSIBLE FOR IRE" LOVING ALL ELECTRICAL DEVICE- (L I GI-IT FIXTURES, RECEPTACLES, SW I TC1 -TES, ETC) AND EQUIPMENT INCLUDING CONDUIT 4 NIRING BACK TO PANEL, THAT 15 NOT BEING REUSED. NOT! -LING SMALL BE ABANDONED IN PLACE. E L E C T R I C A L V E R I F I C A T I O N N O T E : PRIOR TO INSTALLATION OF ROUGH ELECTRICAL WIRING, CONTRACTOR SHALL CHECK NAMEPLATE DATA OF ALL H.V.A.C. EQUIPMENT, WATER HEATERS, AND OTHER EQUIPMENT, IN ORDER TO OBTAIN CORRECT WIRE SIZES, VOLTAGES, AND OVER - CURRENT PROTECTION. ADEQUATE SERVICE CAPACITY MUST BE PROVIDED. SUBJECT TO ELECTRICAL INSPECTION. ELECTRICAL RISER DIAGRAM NOTES: 1. TENANT'S ELECTRICAL CONTRACTOR SHALL COLOR CODE FEEDER CONDUCTORS AT TENANT METER CENTER TO DESIGNATE PHASE NEUTRAL AND GROUND. 2. TENANT'S ELECTRICAL CONTRACTOR SHALL FIELD VER /FY EXACT K.A.I.C. RATING OF LANDLORD'S DISTRIBUTION EQUIPMENT. J. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10X ( +) BETWEEN PHASES: A/B, B /C, A/C REGARDLESS OF CIRCU/17NG INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. f7ELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 6. PANELBOARD(S) TO HAVE BOLT -ON BREAKERS. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 0 9 2010 City of Tukwila BUILDING DIVISION RECEIVED FEB 0 4 2010 PERMIT CENTER