Loading...
HomeMy WebLinkAboutPermit EL10-0184 - MICROSOFTMICROSOFT 3355 S 120 PL EL1O-0184 City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL10 -0184 Issue Date: 03/11/2010 Permit Expires On: 09/07/2010 Tenant: Name: MICROSOFT Address: 3355 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Phone: Address: 12201 TUKVVILA INTL BLVD , 4TH FLOOR Contact Person: Name: JOE WOLF Phone: 206 - 786 -3853 Address: 5005 3RD AV S , SEATTLE WA Contractor: Name: MCKINSTRY ELECTRIC Phone: 206 832 -8513 Address: PO BOX 24567 , SEATTLE WA Contractor License No: MCKINE *982KG Expiration Date: 05/08/2010 DESCRIPTION OF WORK: INSTALLATION OF (22) 3 PHASE 50A 208V BRANCH CIRCUITS, RECEPTACLES, AND BREAKERS. EACH BRANCH CIRCUIT TO INCLUDE (1) L15 -50 RECEPTACLE, (1) #8 -3 MC CABLE (W/#10 GROUND). Value of Electrical: NRES: $21,066.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: 2008 $588.62 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signaturgs" Print Name: (a.-, j,[ /ni�✓2�2 Date: 3 -1/ - /6) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL10 -0184 Printed: 03 -11 -2010 Parcel No.: Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 1023049082 3355 S 120 PL TUKW MICROSOFT PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0184 ISSUED 03/10/2010 03/11/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: �,4i✓ 5� yet' -/L-- Date: 3 —1 /—"7C) doc: Cond -Elec ELI 0-0184 Printed: 03 -11 -2010 CITY OF TUKWILIIO Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. 640-0(91 Project No. .(For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 3355 S 120th PI Suite Number: Tenant Name: Microsoft Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila Intl. Blvd., 4th Floor (001som-5of3.2, Floor: New Tenant: ❑ Yes ..No Tukwila WA 99168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Joe Wolf Mailing Address: 5005 3rd Ave S E -Mail Address: joew @mckinstry.com Day Telephone: Seattle City State Fax Number: (206) 832 -8673 (206) 786 -3853 WA 98134 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: McKinstry Electric 5005 3rd Ave S Seattle WA 98134 City State Zip Contact Person: Brian Skinner Day Telephone: (206) 832 -8403 E -Mail Address: Briansk @mckinstry.com Fax Number: (206) 832 -8514 Contractor Registration Number: MCKINE *982KG Expiration Date: 05/08/2010 Valuation of Project (contractor's bid price): $ 21,066 Scope of Work (please provide detailed information): Installation of (22) 3 phase 50A 208V branch circuits, receptacles, and breakers. Each branch circuit to include (1) L15 -50 receptacle (1) #8 -3 MC cable (w/ #10 ground). Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes ® No Type of Use: Data Center Type of work: ❑ New ® Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line \I -2009 - Electrical Petmit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $145.60 (including an attached garage) ❑ Garages, pools, spas and outbuildings $78.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $57.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $78.00 (no added/altered circuits) ❑ Service change with added/altered circuits $78.00 number of added circuits $11.00 ea ❑ Circuits added/altered without service change $52.00 (up to 5 circuits) ❑ Circuits added/altered without service change $52.00 (6 or more circuits) $7.30 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $57.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $60.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: `�A✓ taut.) S/ <rN,vu Mailing Address: -5 CCs 3' /¢✓2 5 IDate Application Accepted: (0_ I 0 Date: 3- -to-�Q Day Telephone: ZOCo — 8-3 Z — 8103 City 98/3 State Zip _ Date Application Expires: el j V ' 0 Staff Initials: H:\Applications \Forms - Applications On Line \l -2009. Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1023049082 Permit Number: EL10 -0184 Address: 3355 S 120 PL TUKW Status: PENDING Suite No: Applied Date: 03/10/2010 Applicant: MICROSOFT Issue Date: Receipt No.: R10 -00425 Payment Amount: $470.90 Initials: WER Payment Date: 03/11/2010 11:38 AM User ID: 1655 Balance: $0.00 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10769 470.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 470.90 Total: $470.90 PAYMENT RECEIVED doc: Receiot -06 Printed: 03 -11 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: MICROSOFT RECEIPT Permit Number: EL10 -0184 Status: PENDING Applied Date: 03/10/2010 Issue Date: • Receipt No.: R10 -00418 Initials: WER User ID: 1655 Payment Amount: $117.72 Payment Date: 03/10/2010 02:15 PM Balance: $470.90 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10767 117.72 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 117.72 Total: $117.72 doc: Receipt -06 Printed: 03 -10 -2010 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 6iio D PERMIT NO (206)431 -3670 Project: I CAD �� Type of Inspection: No Address: 33 ss S. /2D �. Date Called: Special Instructions: Date Wanted: .m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: rK fAkii Date: o3//2_ h U ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Permit No. PANEL SCHEDULE McKinstry NAME: TK55 /RPP -3-4D 0 -)- 400A 1 - I • -- *gm .•• •ME i•• ■.• '!. ■•E ..• •a•. • 0 , 0 -)- VOLTAGE: 208Y1 120V 3 ph. 4 wire LOCATION: ROOM# 400A BUS 400A 3P MAIN BREAKER 22000 KAIC DESCRIPTION LOAD KVA * TRIP RATING TRIP RATING * LOAD KVA DESCRIPTION COMF DMX 9 -1 Rack 3W151S25 6.1 50/ 3 50/ 3 6.1 COMF DMX 9 -7 Rack 3W144S25 - 2 3 3 3 - 5 -pa• 7 - - 4 -6 3 3 COMF DMX 9 -2 Rack 3W150S25 6.1 50/ 3 50/ 3 6.1 COMF DMX 9 -8 Rack 3W142S25 - 8 3 3 - 9- -10 -12 3 3 11- 13 - COMF DMX' 9 -3 Rack 3W149S25 6.1 50/ 3 50/ 3 6.1 COMF DMX 9 -9 Rack 3W141 S25 - 14 - 16 - 18 3 3 15 - 3 3 17- 19 - 21 - COMF DMX 9 -4 Rack 3W147S25 6.1 50/ 3 50/ 3 6.1 COME DMX 9 -10 Rack 3W140S25 - 20 3 3 - 22 24 3 3 23 - 25 - Si r == ..�_ COMF DMX 9 -5 Rack 3W146S25 6.1 50/ 3 50/ 3 6.1 COMF DMX 9 -11 Rack 311/1 3/IEWED F ®R - 26 3 3�UANCE WITH 27 - ::• - 28 - 30 3 3 � ��� -NEC 29 _ 31 COMF DMX 9 -6 Controller Rack 3W145S25 6.4 50/ 3 K•! 32 3 MAR 1 1 2010 33 - - 34 36 3 35- 37 - .i •38 31S .•• ��• COMP BCMS 1.4 15/ 2 v 39 - - 40 - 42 City of Tukwila 2 DIVI9N 41 - LOAD TYPE CONN. (KVA) NEC CALCULATED FACTOR NEC CALC. PHASE CONN. (KVA) FACTOR (KVA) AMPS LOAD (KVA) NOTES: LTS REC REC HVAC KIT S. LTS COMP MISC 68.8 125% 100% 50% 100% 100% 100% ° 100% 100% 68.8 % ` 01511 A: B: C: 22.5 23.2 23.2 100% 100% 100% 22.5 23.2 23.2 187 193 193 NEC TOTAL: 68.8 68.8 '191 * CIRCUIT BREAKER CODE G = GFCI H = HID RATED S = SHUNT TRIP D = SWITCHING DUTY FED FROM: DOWNSTREAM LOAD INFORMATION TOTAL 68.8 100% 68.8 FEEDER LENGTH: ECEIVEp DOUBLE LUGS LUGS FEEDER: DATE: MAR 10 2010 PERMIT CENTER • • T COPY PLAN VIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0184 PROJECT NAME: MICROSOFT SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # DATE: 03 -10 -10 Response to Incomplete Letter # Revision # After Permit Issued D1EPARTIyIENTS: %_\kO C 6hding Division • Public Works n Fire Prevention n Structural ❑ Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 03-11 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 04-08-10 Approved ❑ Approved with Conditions K Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P oer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is.a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Mckinstry Electric 2067623311 Po Box 24567 Seattle Wa 98124 King Limited Liability Company Parent Company Facility Electrical Srvcs Llc UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602198837 Active MCKINE'982KG Electrical Contractor 5/7/2002 5/8/2010 General Unused MASTER ELECTRICIAN INFORMATION License ZEHNER'962CJ Name Zehner, Rick A Status Active Business Owner Information Name Role Effective Date Expiration Date Black, Stephen Partner /Member 05/07/2002 Allen, Dean C Partner /Member 05/07/2002 Moore, Douglas J. Partner /Member 05/07/2002 Teplicky, J. William Partner /Member 05/07/2002 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 TRAVELERS CAS e SURETY CO 103737415 04/29/2002 Until Cancelled $4,000.00 05/07/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip/Print.aspx 03/11/2010