Loading...
HomeMy WebLinkAboutPermit EL10-0190 - TOYS R US / BABIES R USTOYS R US/BABIES R US 17501 SOUTHCENTER PY EL1O-0190 Parcel No.: Address: Suite No: City ("Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 2623049067 17501 SOUTHCENTER PY TUKW ELECTRICAL PERMIT Permit Number: EL10 -0190 Issue Date: 06/02/2010 Permit Expires On: 11/29/2010 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: TOYS R US / BABIES R US 17501 SOUTHCENTER PY SUITE 300 , TUKWILA WA CLPF- TUKWILA LP Phone: C/O JSH PROPERTIES INC , 10655 NE 4TH ST #300 RYAN NOAKES - PAEP ARCHITECTURE ENGINEERING Phone: 616 - 447 -3437 1811 4 MILE ROAD NE , GRAND RAPIDS MI Contractor: Name: HUMBLE ELECTRIC LLC Address: 1330 21 ST SE , AUBURN WA Contractor License No: HUMBLEL954B5 Phone: 253 804 -8370 Expiration Date: 01/25/2011 DESCRIPTION OF WORK: NEW POWER WALL, LIGHTING, ETC. FOR INTERIOR RENOVATION OF EXISTING (FORMER) LINENS N THINGS AND K & G FASHION SUPERSTORE Value of Electrical: NRES: $250,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied ami ith, Fees Collected: $4,341.75 National Electrical Code Edition: 2008 Date: ail 02-t 70 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: Print Name: 0 t _tS/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 ELI 0-0190 Printed: 06 -02 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htqx//www.ci.tukwila.wa.us Parcel No.: 2623049067 Address: Suite No: Tenant: 17501 SOUTHCENTER PY TUKW TOYS R US / BABIES R US PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0190 ISSUED 03/11/2010 06/02/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Y Date: (e ( j70 doc: Cond -Elec EL10 -0190 Printed: 06 -02 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. ELlO- Ot9O (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 17501 Southcenter Parkway Tenant Name: Toys "R" Us / Babies "R" Us Property Owners Name: JSH Properties, Inc. - John Chelico Mailing Address: 2003 Western Ave, Suite 200 Suite Number: 300 Floor: New Tenant: ® Yes ❑..No WA 98121 Zip Seattle City State CONTACT PERSON Who do we contact when your permit,is ready;to be issued Name: PAEP Architecture Engineering, P.C. Mailing Address: E -Mail Address: 1811 4 Mile Road, NE noakesr @progressiveae.com Day Telephone: (616) 447 -3437 Grand Rapids MI 49525 City State Zip Fax Number: (616) 361 -1493 ELECTRICAL CONTRACTOR INFORMATION Company Name: TBD Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 250,000 Scope of Work (please provide detailed information): New power wall, lighting, etc. for interior renovation of existing (former) Linens N Things and K &G Fashion Superstore. Will service be altered? ® Yes ❑ No Adding more than 50 amps? ❑ Yes ® No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ® Fire Alarm Property Served by: ® Puget Sound Energy ❑ Seattle City Light H:\ApplicationsTorms- Applications On Linet2010 Applications \1.2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Ryan T. Noakes Mailing Address: 1811 4 Mile Road, NE Date: 03/09/2010 Day Telephone: (616) 447 -3437 Grand Rapids MI 49525 City State Zip IDate Application Accepted: -1 --1, 0 Date Application Expires: Staff Initials: H:\Applications\Fmms- Applications On Line \2010 Applications \I.2010 - Electrical Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049067 Permit Number: EL10 -0190 Address: 17501 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -00969 Initials: User ID: Payee: JEM 1165 Payment Amount: $3,473.40 Payment Date: 06/02/2010 08:51 AM Balance: $0.00 HUMBLE ELECTRIC LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7666 3,473.40 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 3,473.40 Total: $3,473.40 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -02 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049067 Permit Number: EL10 -0190 Address: 17501 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 03/11/2010 Applicant: TOYS R US / BABIES R US Issue Date: Receipt No.: R10 -00434 Initials: WER User ID: 1655 Payment Amount: $868.35 Payment Date: 03/11/2010 02:19 PM Balance: $3,473.40 Payee: PROGRESSIVE /AE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 38394 868.35 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 868.35 Total: $868.35 PAYMENT RECEIVED doc: Receiot -06 Printed: 03 -11 -2010 INSPECT ON NO. INSPECTION RECORD Retain a copy with permit 610- 00 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43113670 Permit Inspection Request Line (206) 431 -2451 Project: / � g �1) Type of Inspection: too Address: �q! «5-01 5.C..• Py. Date Called: Instructions: Date Wanted: �� Qf .b p.m Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. C.5 COMMENTS: D (,10043 f Inspector: + 6 L °46 am Date: (a of /10 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. � INSPECTION RECORD ( Retain a copy with permit 104'0° 0 E 70 INSPECTION NO. j PERMIT N . CITY OF TUKWILA BUILDING DIVISION r< 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 6� R. c5' Type of Inspection: /27ao Address: J �7P i �s.e P7. Date Called: Special Instructions: Date Wanted: /9 3d /am�ti Requester: ""' Phone No: Approved per applicabi codes. COMMENTS: Corrections required prior to approval. 3 A4 9JQt( PA.J ,1Jo(),r Old 50)16 A9 mar 1,06g_v_w l p • CL AAii�+ & v < g�, I c10A/f &eT- f & o Fhc rt2(A'5 $Pw5 tp.4 id &0. (4 KR oo/1 nvoJ cla, t, d r • 6P CetuJ0D5. col 1'Z 4) -7 &,,( FA 1/9-1 • �U ��►� * —& fie+ en 4 Inspector: Date: b7/30e0 n REINSPECTIO FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION1z- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431 -2451 Project: � � g � Y U Type of Inspection: .1 �� Address: 1-7501 S-C-9 P Py. Date Called: 0, Special Instructions: Date Wanted: ?/3 a.m: Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 4.01 rili5Pccr6.9 Inspector: Date: 1),?/3 n REINSPECTION'FEE REQUIRED. Orior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPEC1110N NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. L6 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 1(L Project: ---- `{fit 1 /) V J Type of Inspection: ®� Address: 175615 -l., /� Pt Date Called: Special Instructions: Date Wanted: 70I 1 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: 04( Sfik\lia Inspector: IO Date: 60//10 REINSPECT FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. 4 - CITY OF TUKWILA BUILDING DIVISION -- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: %` � ` n�/ d/(\ !4 Type of Inspection: AddressII' ' ��50� s.e. Date Called: -- Special Instructions: Date Wanted: Q U 3c% p.m. Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: - ,Q.i41 c(E c rirr C C L-lm sipe /,l irloA orfiD r tAtlie {St.LF all, id. tat AI idle k flknt)n(DrI41 P 4! to i - 5k?' I A.'t14N1v,FACTl ia15 56t9r-- 8PNAC-4613 1)9 (A LASp ( ta'l eDnlDoc_ra 9 ipt) ff aJ r t)6 PeRFoRIANisC TE57 RC-skit-7-5 oF„A FP p9/1 Inspector: fiel Date: de 30/1 0 REINSPECTIO FEE REQUIRE I . Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEC ON NO. PERMIT NO. 6) o 1 0 (6 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: I ! 5 K J5 Type of Inspection: ®ve Address: l7S�r s•L, p�. Date Called: Special Instructions: Date Wanted: ��m. rn' Requester: Phone No: ❑ Approved per applicable codes. - ❑ Corrections required prior to approval. COMMENTS: Air Iin &&9C, o rci i4ic - P a 6 CA1,ato . r' C ,4*,/4 v 1 .4, 5 tr& 1(�I r - , (aI;Piis ( Inspector: Date: 0/2.7/10 n REINSPECTION FEE REQUIREb. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �= 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 ei1to- flo Project: n Type of Inspection: 7803 Address: 17501 5.e- Pi, Date Called: Special Instructions: Date Wanted: g24 �m �r}� Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: c gis:Aft 1 Inspector: Date: Ogiztif/o n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ,610 -v170 Project:1- K V i e Type of Inspection: ��� Address: 1795i Date Called: Special Instructions: Date Wanted: zi�Y aren Requester: Phone No: rjApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: A- 6-weis FKanIT JESii�J�� Inspector: ! // I 1 k3riJ,Jez Date: 0% it.t.t 110 ri $60.00 REINSPECTION FEE REQU ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: nir._r,�,,:- .,ti�h..,.T..r - r-✓✓ ci` ��- 3s�- v`'-.,- e-"'^ a1.-...:..,.,..-.. oti- ..�:✓'7e_`- .-z`-""d'�"--�,.. INSPECAION NO. INSPECTION RECORD Retain a copy with permit 610 -oig0 PERMIT NO. (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188. Project: /� I g 16 5 `[l Type of Inspection: /'�" 7 , 00/..._ Address: 1791 5.C. Date Called: - /4 , 604 0 aJcro0 To gf J I-n F,t-0 LAM -It y l4/ -PE oR, TRAc.t Special Instructions: Date Wanted: 7 zy p.m. Requester: Phone No: LiApproved per applicable codes. VICorrections required prior to approval. COMMENTS: ii -- /cl ) izcxeM of pt.f c ec,Al/n/acro125 . /50L -Arr 6 ovd Ta - did "- r 4" 5oti2CE , 772,445FderfiL G2u,JD - PR.aJ' DC A»Dn okl i5t11E- 5+1P?o(r r..4\ - /4 , 604 0 aJcro0 To gf J I-n F,t-0 LAM -It y l4/ -PE oR, TRAc.t Inspector: : 164161\ Date: 0 zyho El $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: INSPE ION NO. INSPECTION RECORD Retain a copy with permit'4/0-O /90 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ,p -7DYSI� G/�ARitcle I is Type of Inspection: -20'03 M — 70-0 / Address: /20/ 5 Co ht) y Date Called: Special Instructions: Date Wanted: �/0 a.m. p.m. Requester: Phone No: �Z.,ec /7i'4- oved per applicable codes. Corrections required prior to approval. COMMENTS: M — 70-0 / bol L//LA uc -7 ,- fri2oii.1T ) / /Cir- 5 �Z.,ec /7i'4- Nfii-L- Inspector: 2 ,:9)trri.:1Xneg/ Date: /0/j0 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: E_..- 1^�.�..,t- •?- .S'h�;-F`?'��'r�. -cam+.: ?-.rte sT�- .�.•��s,+,. "'T- .,sit *-�+, r'Sd- !��•:r ..:a. - :aEr3'�^4. -,. INSPECTION NO. INSPECTION RECORD. Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project775 n s •K` (� Type of Inspection: 7�/ 700 Address: Date Called: Special Instructions: Date Wanted: O a:m: /0/ Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 700 ilt.5LAir5 C NIDJAT5 per 6ky oi taS/ tw btratf7A 'Arm A iJ - Stla ri0a-r■-t , l Inspector: Date: ri $60.00 REINSRECTION FEE REQ 1 IRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ha::1f.":�YN"tF- ':V1._r...�... �-.a 1..�r•.t�4±"al�.. ; r __�'iv.h:`Y`a2'Wr" /'.<i `ate'. LS.'.l..ad .. J�Y'F INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6, (o CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: ,i r ' Rio, �� Type of Inspection: �OV 3 Address 11 Sir 3.c,. P�. Date Called: .--. Special Instructions: Date Wanted: 7 o7 // m. Requester: Phone No: 0 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Es aM5 A/JD Rpoti cJ mi wrow % c � C , 51O E/i `t i U(Al A3 < Date: 07/07 /to $60.00 REINSP CTION FEE REQUI ED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: • Ifo PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0190 DATE: 03- 11 -10 PROJECT NAME: TOYS R US / BABIES R US SITE ADDRESS: 17501 SOUTHCENTER PY SUITE 300 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Atk)C 19_fO Building Division gp Fire Prevention Public Works ❑ Structural Planning Division F1 Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 03-16 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further. Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -13-10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople P�er Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Humble Electric Llc 2538048370 1330 21St St Se Auburn Wa 98002 King Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602454709 Active HUMBLEL954B5 Electrical Contractor 1/25/2005 1/25/2011 General Unused es License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HUMBLE*973DR Humble Electric Electrical Contractor General Unused 3/19/2003 3/19/2005 Out Of Business MASTER ELECTRICIAN INFORMATION License HUMBLT'968JF Name Humble, Tony Status Active Business Owner Information Name Role Effective Date Expiration Date Humble, Tony Agent 01/25/2005 Humble, Tony Partner /Member 01/25/2005 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OLD REPUBLIC SURETY CO YLI243915 01/06/2005 Until Cancelled $4,000.00 01/25/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 06/02/2010 GENERAL NOTES: 1. BEFORE SUBMITTING THE BID PROPOSAL, EC SHALL VISIT THE JOB SITE & FULLY ACQUAINT HIMSELF WITH THE JOB CONDITIONS, VERIFY SERVICE CONNECTIONS, INCLUDING ALL NECESSARY PULLBOXES, SIZE & NUMBER OF CONDUITS AND CONDUCTORS, SWITCHGEAR, METERING, CABLE CHARGES, ETC. WHETHER SHOWN ON DRAWINGS OR NOT BUT REQUIRED BY SERVING UTILITY COMPANY, TO MAKE A COMPLETE AND OPERATING ELECTRICAL SERVICE WITHOUT ADDITIONAL COST TO THE OWNER. VERIFY SERVICES AND CHARGES WITH POWER AND TELEPHONE COMPANIES. 2. EC SHALL COORDINATE HIS WORK WITH THAT OF ALL OTHERS & SHALL INSTALL LIGHTING FIXTURES SYMMETRICALLY WITH AISLE AND /OR DIMENSIONS AND ACCOMMODATE FIXTURES WITH OTHER EQUIPMENT INSTALLATIONS. PRIOR TO FINISH OF AFFECTED WORK, EC SHALL INSTRUCT THE OWNER AND /OR MANAGER ON THE USE AND MAINTENANCE OF ELECTRICAL SYSTEM. Q 3. EC SHALL VERIFY ALL REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND SPECIFICATIONS, AND SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED BY MC FOR COMPLETE INSTALLATION. 4. ALL EXHAUST FANS, TRANSFER FANS, ETC. ARE TO BE ABOVE OFFICE NEAR ROOF. 5. DISCONNECT MEANS AND OVERCURRENT PROTECTION SHALL BE INSTALLED ON ALL MOTORS TO COMPLY WITH CODE. 6. ALL DISCONNECT SWITCHES SHALL BE "HORSEPOWER RATED" FOR THE MOTOR CONNECTED. 7. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH LATEST "N.E.C." AND ALL LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT AMONG REQUIREMENTS, THE MORE RESTRICTIVE SHALL APPLY. 8. ELECTRICAL DEVICES FOR USE OUTSIDE THE BUILDING SHALL BE WEATHERPROOF. 9. FUSES SHALL BE AS MANUFACTURED BY BUSSMAN CO., UNO. 10. GROUND ELECTRICAL EQUIPMENT PER "N.E.C." AND LOCAL CODE REQUIREMENTS. 11. THE ONLY CONDUIT PERMITTED ON BUILDING COLUMNS IN THE SALES AREA WILL BE FED FROM ABOVE FOR THE SENSOR, UNO. 12. NO CONDUIT, DISCONNECTS, ETC., SHALL BE ROUTED ACROSS , OR MOUNTED ON, FRONT WALL. CONDUITS SHALL BE ROUTED IN SLAB OR WITHIN WALL OR CHASE. 13. ALL CONDUCTORS SHALL BE #12, 1/2" C. AND ARRANGED PHASE TO NEUTRAL, EXCEPT AS OTHERWISE NOTED OR AS REQUIRED FOR VOLTAGE DROP. (SEE SPECS.) 14. ALL CONDUIT FOR ELECTRICAL, TELEPHONE , DATA, SECURITY AND LOW VOLTAGE DEVICES SHALL BE RUN CONCEALED IN CMU WALLS OR DRYWALL PARTITIONS, UNO. 15. EACH ISOLATED GROUND CIRCUIT SHALL CONSIST OF INDIVIDUAL UNGROUNDED, GROUNDED AND ISOLATED GROUND CONDUCTORS. DO NOT SHARE NEUTRALS OR ISOLATED GROUND CONDUCTORS BETWEEN CIRCUITS. 16. ANY CONDUITS REQUIRED TO BE MOUNTED ON SALES FLOOR COLUMNS SHALL BE MOUNTED ON BACK SIDE OF COLUMN (FACING REAR OF STORE.) 17. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONDUIT FROM THE KNOX BOX LOCATION INTO THE BUILDING. 18. REFER TO SHEET E102 FOR ADDITIONAL PHOTOCELL ZONE CONTROL INFORMATION. 19. ALL POWER, DATA, AND LV MOUNTED ON SALES AREA COLUMNS SHALL BE SURFACE MOUNTED BOXES W/ WIRING RUN THROUGH COLUMNS. (TYPICAL FOR ALL) DIVISION OF RESPONSIBILITY FURNISHED INSTALLED BY BY PRIMARY CONDUIT PRIMARY CONDUCTORS TRANSFORMER PAD BOLLARDS SECONDARY CONDUIT SECONDARY CONDUCTORS TRANSFORMER CONNECTIONS (PRIMARY) TRANSFORMER CONNECTIONS (SECONDARY) BUILDING EXTERIOR SERVICE DISCONNECT CT ENCLOSURE CT'S METER SOCKET METER ABBREVIATIONS C - CONTRACTOR L - LANDLORD U - UTILITY COMPANY ETR - EXISTING TO REMAIN NAME UTILITY COMPANY ADDRESS CITY, STATE ZIP PHONE FAX KEY NOTES: 1 A LL RTU S ARE FA C TOR Y FU RN ISHED WITH MAIN CIRCUIT BREAKERS, WEATHERPROOF SERVICE RECEPTACLES AND SMOKE DETECTORS. RTU'S ARE FURNISHED WITH "BOTTOM POWER ENTRY" KIT FOR ELECTRICAL FEEDERS. SEPARATE PENETRATION OF ROOF AND ROOF DECK WILL NOT BE REQUIRED. CONTRACTOR SHALL COORDINATE ALL FINAL CONNECTIONS WITH RTU INSTALLER. 2 IN DOOR HEADER FOR DOOR OPENER. PROVIDE 4 #12 FROM OPERATOR DOOR ACTUATOR FOR SYSTEM'S LOW VOLTAGE WIRING. CONNECT AS DIRECTED BY DOOR INSTALLER. VERIFY ALL REQUIREMENTS AND CONNECTIONS WITH DOOR SYSTEM MANUFACTURER, TYPICAL FOR ALL S LIDING DOORS. 3 EC SHALL PROVIDE ALL WIRING, JUNCTION BOXES AND MAKE FINAL CONNECTIONS TO ALL SIGNS. SIGNS ARE PROVIDED BY OTHERS. EC SHALL COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. 4 NOT USED 5 EC SHALL KEEP MAIN CONDLjFT RUNS AT LRAST 6' -0" FROM MAIN AISLEWAYS, "RACEWAY". MAIN CONDUIT RUNS ACROSS AISLEWAYS SHALL BE RUN PERPENDICULAR AND S. ;puL NOT RUN PARALLEL DOWN AISLEWAY. 6 PROVIDE NEMA L14-2R CONNECTOR,FOR EACH DECK MOUNTED BIKE LIFT. BIKE LIFT SWITCHES &h `,.1, BE SURFACE MOUNTED AT 54" AFF TO PLYWOOD, WITH 1" RMC ,2.0M DECK, SEE ARCH. DRAWINGS. 7 NOT USED 8 MOUNT ON EXTERIOR 'Wt L CQORDINATE LOCATION WITH EXTERIOR CAMERAS. 9 MOUNT IN JOIST AREA, COORDINATE LOCATION WITH PUBLIC VIEW MONITOR. 10 MOUNT ABOVE CEILING, COORDINATE LOCATION WITH PUBLIC VIEW MONITOR. 'f 11 EC SHALL CONNECT EF -1 TO MOTOR STARTER. (SEE EMS-1) 12 EC SHALL FURNISH AND INSTALL DISCONNECT SWITCH AT 5' -0" AFF AND MOUNT J -BOX AT 8' -0" AFF ON WALL ABOVE DISC. SWITCH AND CONNECT TO BALER 13 EC SHALL ABANDON EXISTING RTU. REMOVE ALL EXISTING POWER AND CONDUIT. ABBREVIATIONS: AFF AHU BRU EC EF EMS EWC FACP GFI GP IG JB LV MC MDP NL NIC OC OSI PC RGC RMC RTU TRU UH UNO WP W/ ABOVE FINISHED FLOOR AIR HANDLING UNIT BABIES' R. US ELECTRICAL CONTPAM -OR EXHAUST FAN ENERGY MANAGEMENT SYSTEM ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL GROUND FAULT CIRCUIT INTERRUPTER GENERAL PURPOSE ISOLATED GROUND JUNCTION BOX LOW VOLTAGE MECHANICAL CONTRACTOR MAIN DISTRIBUTION PANEL NIGHT LIGHT NOT IN CONTRACT ON CENTER OWNER SUPPLIED ITEM PLUMBING CONTRACTOR RIGID GALVANIZED CONDUIT RIGID METAL CONDUIT ROOF TOP UNIT TOYS 'R' US ' UNIT HEATER UNLESS NOTED OTHERWISE WEATHER PROOF WITH \✓ BAILER MDP - 50, 52, 54 COMPACTOR MDP - 49, 51, 53 ■\ m N rommaly 40 ... RTUL'.- ; _ I I t% J. MDP - 31,33,35 ;, 1 ` L i r- _ `. 1. �-LB -13 - j HA - 40 1 _ -i 1 Tr L. ! r i. 1 I LI, j 1 1 i—? 1' I 1 I l ii 1 RTU \EL- L fi I ri 4., ;I: 1 1 -°f --n- tl!. I �- L- 11 1. LA -23 L _ I ELECTRONICS PRE-SALES 121 11101411 PSALES -,r —i 11 _L 16 LC -31 I -pPr T I i I a _a_ " / / / —r. / J / / / LB -22 LC -26 � p 1 Y 1 J / / f - -. l I I j i I L - L , LA 21 :- i i I r,!a. w 1•I Link 10 - MDP - 26,28,301 / M r 0 I-IA -36 (s) LA - 17 LA- 19� RECEIVING 84" - I.. LA -17 - 60" 120 11:,1 LA 19_C 15 84" CW:) -$AQIK "SIDE OP 00L`1JMN FA IL w I _- 1 I i r'T -T1 1-:,- - - • 'sue rr{ a-- � I 1F- Hit 1 lam,' [1+0 ,t 111111 j R I I RTU 0 61 -6" LFI ,'-:H -A BFI 5 i,VP L ^-Jy 1! 'C'7 r' -r n 1 ESACK SIpE OF CC$L MN Fib ING REAR WALL 1 ' II ' ' 1 1 1 EIS J RY VESTIi3ULE 1 402 /'i f /f /i` /I % ,/ / ;'''i I i -7I • l�'., ..vim < € // / I0T , 1 Ij 1 C 1 aA I I I n 1 E201 / / _I I 1' li IL LJ -- I- ' i 1 A ' # i - -1 _ N M 1 1 Jg fi; .L�II -r, II P--S 1 I L LA -21 - -; GFI I T- IS ;� MDP - 13,15, 17-T--7"---7-----.171 __SALES % f / •iii Ir— _. ' -ii +��►REA�1 _ / • ,i\ 11 ! _ �I 101 / I' / ,/ , / ill /11 !- ! 6' -6" r..- J _X LC - 2 1 ,t- T 1 -_.e- 1i I'/ Fir —7 TA • J -1 • _1 1 • I -� LB -5 • i 1 %; � GEL MDP- 19,21,23- i 1MDP - 20,22,24 "LD -2" & "C -2" "LD -1" & /1\1 EMS CABINET 150KVA X -FMR "T -1" MOUNTED ABOVE POWER WALL \ i\ ( 3) "LA" (SECTION 1) "LA" (SECTION 2) 111J /1 4 - 111/'1( A _ I \NN j MAIN SERVICE ENTRANCE "MDP" POWER WALL KEY PLAN SCALE = 1/8" = 1' -0" 1 WM NI e*iltif t a OTANOTG:O 1 3 1 LA -1,3 1 • !i_ii_I: LC - 1 • _ O IMGirretliro 0 p EXIT VESTJBULE-.. LB - 1 7 5 '75 LA - 5, 7 57 ELECTRICAL POWER PLAN E101 / SCALE = 1/16" = 1' -0" e.p IC � %1 7' I I> 11,, 1617- 11 / BACK $11YEIOF OLUMN FAAAAA.pN REAR - WALL -- 1 -i. �/;Y WP lig GFI A6 SPRINKLER RISER . 110 PLAN Jai • MANAGER'S OFFICE 111 TRUE NORTH COUNT ROOm 112 PROCESSING ROOM 106 BIKE LIFT BKE LIFT BIKE LIFT BIKE LIFT 'cE LIFT NNW EQUIPMENT ROOM 107 FILE COPY Permft No. SI-10 0(10 Plan review approval is subject to enors and omissions. Approval of construction documets does not authorize , the violation of any adopted code or ordinance. Receipt of approved Field Copy and cone*. is is acknowledged: Date: B:citYLD/ ING2;;Ibitwnao(ivIsin REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 1 9 2010 ‘11. (14( ity of Tukwila BUILDING DIVISION RECEIVED MAR 1 1 2010 PERMIT CENTER EL1()-0196 r CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION I MI 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE 0 10/28/09 DESCRIPTION 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE ENGINEERS cgc CONSULT 923 MAIN STREET, N. WILKESBORO, NC 286 PHONE: 336-667-4225 FAX: 336-667- 32 NTS STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA WA DRAWING TITLE ELECTRICAL POWER PLAN SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. E101 AR ELECTRICAL LEGEND: FLUORESCENT (UPPERCASE LETTER INDICATES FIXTURE TYPE, NUMBER INDICATES CIRCUIT, LOWER CASE LETTER INDICATES SWITCHING). (PC) PRICE CHECKER LOCATIONS Alb ® 8'-0" LINEAR EMERGENCY FLUORESCENT LIGHT (CTR) CUSTOMER CENTER W/ INTEGRAL PRICE CHECKER 4'-0" LINEAR EMERGENCY FLUORESCENT LIGHT SINGLE POLE SWITCH - BLACK W/ SS COVER PLATE, MTD 48" A.F.F. SEE SPECIFICATIONS. 8' -0" LINEAR FLUORESCENT LIGHT o WALL MOUNT OCCUPANCY SWITCH, 48" AFF:, 30 MINUTE DELAYED "OFF", #ODS10 -IDI (LEVITON), BY EC. I 1 4'-O" LINEAR FLUORESCENT LIGHT JUNCTION BOX MTD. IN JOIST AREA FOR CONNECTION TO RACKING. CONDUITS CONNECTED BETWEEN SUCH BOXES SHALL BE ROUTED IN JOIST AREA. J Ilml ❑ 2X4 FLUORESCENT LIGHT Q JUNCTION BOX. GP au DUPLEX RECEPTACLE - MTD 15" AFF TO CENTER. U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. WALL MOUNTED LIGHTING GP QUAD RECEPTACLE - MTD 15" AFF TO CENTER, U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. O INCANDESCENT OR HIGH INTENSITY DISCHARGE IG o - DUPLEX RECEPTACLE, ISO GND- ORANGE, MTD 15" AFF TO CENTER U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. EXTERIOR WALL MOUNTED FIXTURE - IG ii QUAD RECEPTACLE, ISO GND- ORANGE, MTD 15" AFF TO CENTER U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. MtEXIT SIGN GFI DUPLEX RECEPTACLE GFI- BLACK, MTD 15" A.F.F. TO CENTER, U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. Q KEY NOTES �^'P�GFI WEATHER PROOF QUAD RECEPTACLE GFI MTD 15 A.F.F. C " WEAT A F.F. TO ENTER, U.N.O. SEE SPECIFICATIONS FOR TYPE, COLOR, AND PLATE. PANEL EXIT DISCHARGE LIGHTING DISCONNECT SWITCH (NON -FUSED EXCEPT AS NOTED) MOTORS TRANSFORMER_ f 120V FUSED DISCONNECT SWITCH. BUSSMAN TYPE SSY OR EQUAL. T PUSH BUTTON- EDWARDS #852 MOUNTED AT 44" AFF (1) 3' -0" SECTION OF PLUGMOLD, WIREMOLD #2000GB SERIES WITH RECEPT. 6" OC, WHITE, BY EC. • BUZZER- EDWARDS #340A -G5 I Y O Yr 11 (2) 3 -0 SECTIONS OF PLUGMOLD MOUNTED BACK TO BACK, WIREMOLD #2000GB SERIES WITH RECEPT. 6" OC, WHITE, BY EC. 0 CEILING OCCUPANCY SENSOR, SELF - CONTAINED, 277V, 30 MINUTE DELAYED "OFF ", #ODSOS -17W {LEVITON), BY EC. POWER POLE REVISION DELTA P GENERAL NOTES: 1. BEFORE SUBMITTING THE BID PROPOSAL, EC SHALL VISIT THE JOB SITE & FULLY ACQUAINT HIMSELF WITH THE JOB CONDITIONS, VERIFY SERVICE CONNECTIONS, INCLUDING ALL NECESSARY PULLBOXES, SIZE & NUMBER OF CONDUITS AND CONDUCTORS, SWITCHGEAR, METERING, CABLE CHARGES, ETC. WHETHER SHOWN ON DRAWINGS OR NOT BUT REQUIRED BY SERVING UTILITY COMPANY, TO MAKE A COMPLETE AND OPERATING ELECTRICAL SERVICE WITHOUT ADDITIONAL COST TO THE OWNER. VERIFY SERVICES AND CHARGES WITH POWER AND TELEPHONE COMPANIES. 2. EC SHALL COORDINATE HIS WORK WITH THAT OF ALL OTHERS & SHALL INSTALL LIGHTING FIXTURES SYMMETRICALLY WITH AISLE AND /OR DIMENSIONS AND ACCOMMODATE FIXTURES WITH OTHER EQUIPMENT INSTALLATIONS. PRIOR TO FINISH OF AFFECTED WORK, EC SHALL INSTRUCT THE OWNER AND /OR MANAGER ON THE USE AND MAINTENANCE OF ELECTRICAL SYSTEM. Q 3. EC SHALL VERIFY ALL REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND SPECIFICATIONS, AND SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED BY MC FOR COMPLETE INSTALLATION. 4. ALL EXHAUST FANS, TRANSFER FANS, ETC. ARE TO BE ABOVE OFFICE NEAR ROOF. 5. DISCONNECT MEANS AND OVERCURRENT PROTECTION SHALL BE INSTALLED ON ALL MOTORS TO COMPLY WITH CODE. 6. ALL DISCONNECT SWITCHES SHALL BE "HORSEPOWER RATED" FOR THE MOTOR CONNECTED. 7. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH LATEST "N.E.C." AND ALL LOCAL CODES AND ORDINANCES. IN CASE OF CONFLICT AMONG REQUIREMENTS, THE MORE RESTRICTIVE SHALL APPLY. 8. ELECTRICAL DEVICES FOR USE OUTSIDE THE BUILDING SHALL BE WEATHERPROOF. 9. FUSES SHALL BE AS MANUFACTURED BY BUSSMAN CO., UNO. 10. GROUND ELECTRICAL EQUIPMENT PER "N.E.C." AND LOCAL CODE REQUIREMENTS. 11. THE ONLY CONDUIT PERMITTED ON BUILDING COLUMNS IN THE SALES AREA WILL BE FED FROM ABOVE FOR THE SENSOR, UNO. 12. NO CONDUIT, DISCONNECTS, ETC., SHALL BE ROUTED ACROSS , OR MOUNTED ON, FRONT WALL. CONDUITS SHALL BE ROUTED IN SLAB OR WITHIN WALL OR CHASE. 13. ALL CONDUCTORS SHALL BE #12, 1/2" C. AND ARRANGED PHASE TO NEUTRAL, EXCEPT AS OTHERWISE NOTED OR AS REQUIRED FOR VOLTAGE DROP. (SEE SPECS.) 14. ALL CONDUIT FOR ELECTRICAL, TELEPHONE , DATA, SECURITY AND LOW VOLTAGE DEVICES SHALL BE RUN CONCEALED IN CMU WALLS OR DRYWALL PARTITIONS, UNO. 15. EACH ISOLATED GROUND CIRCUIT SHALL CONSIST OF INDIVIDUAL UNGROUNDED, GROUNDED AND ISOLATED GROUND CONDUCTORS. DO NOT SHARE NEUTRALS OR ISOLATED GROUND CONDUCTORS BETWEEN CIRCUITS. 16. ANY CONDUITS REQUIRED TO BE MOUNTED ON SALES FLOOR COLUMNS SHALL BE MOUNTED ON BACK SIDE OF COLUMN (FACING REAR OF STORE.) 17. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING CONDUIT FROM THE KNOX BOX LOCATION INTO THE BUILDING. 18. REFER TO SHEET E102 FOR ADDITIONAL PHOTOCELL ZONE CONTROL INFORMATION. 19. ALL POWER, DATA, AND LV MOUNTED ON SALES AREA COLUMNS SHALL BE SURFACE MOUNTED BOXES W/ WIRING RUN THROUGH COLUMNS. (TYPICAL FOR ALL) DIVISION OF RESPONSIBILITY FURNISHED INSTALLED BY BY PRIMARY CONDUIT PRIMARY CONDUCTORS TRANSFORMER PAD BOLLARDS SECONDARY CONDUIT SECONDARY CONDUCTORS TRANSFORMER CONNECTIONS (PRIMARY) TRANSFORMER CONNECTIONS (SECONDARY) BUILDING EXTERIOR SERVICE DISCONNECT CT ENCLOSURE CT'S METER SOCKET METER ABBREVIATIONS C - CONTRACTOR L - LANDLORD U - UTILITY COMPANY ETR - EXISTING TO REMAIN NAME UTILITY COMPANY ADDRESS CITY, STATE ZIP PHONE FAX KEY NOTES: 1 A LL RTU S ARE FA C TOR Y FU RN ISHED WITH MAIN CIRCUIT BREAKERS, WEATHERPROOF SERVICE RECEPTACLES AND SMOKE DETECTORS. RTU'S ARE FURNISHED WITH "BOTTOM POWER ENTRY" KIT FOR ELECTRICAL FEEDERS. SEPARATE PENETRATION OF ROOF AND ROOF DECK WILL NOT BE REQUIRED. CONTRACTOR SHALL COORDINATE ALL FINAL CONNECTIONS WITH RTU INSTALLER. 2 IN DOOR HEADER FOR DOOR OPENER. PROVIDE 4 #12 FROM OPERATOR DOOR ACTUATOR FOR SYSTEM'S LOW VOLTAGE WIRING. CONNECT AS DIRECTED BY DOOR INSTALLER. VERIFY ALL REQUIREMENTS AND CONNECTIONS WITH DOOR SYSTEM MANUFACTURER, TYPICAL FOR ALL S LIDING DOORS. 3 EC SHALL PROVIDE ALL WIRING, JUNCTION BOXES AND MAKE FINAL CONNECTIONS TO ALL SIGNS. SIGNS ARE PROVIDED BY OTHERS. EC SHALL COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. 4 NOT USED 5 EC SHALL KEEP MAIN CONDLjFT RUNS AT LRAST 6' -0" FROM MAIN AISLEWAYS, "RACEWAY". MAIN CONDUIT RUNS ACROSS AISLEWAYS SHALL BE RUN PERPENDICULAR AND S. ;puL NOT RUN PARALLEL DOWN AISLEWAY. 6 PROVIDE NEMA L14-2R CONNECTOR,FOR EACH DECK MOUNTED BIKE LIFT. BIKE LIFT SWITCHES &h `,.1, BE SURFACE MOUNTED AT 54" AFF TO PLYWOOD, WITH 1" RMC ,2.0M DECK, SEE ARCH. DRAWINGS. 7 NOT USED 8 MOUNT ON EXTERIOR 'Wt L CQORDINATE LOCATION WITH EXTERIOR CAMERAS. 9 MOUNT IN JOIST AREA, COORDINATE LOCATION WITH PUBLIC VIEW MONITOR. 10 MOUNT ABOVE CEILING, COORDINATE LOCATION WITH PUBLIC VIEW MONITOR. 'f 11 EC SHALL CONNECT EF -1 TO MOTOR STARTER. (SEE EMS-1) 12 EC SHALL FURNISH AND INSTALL DISCONNECT SWITCH AT 5' -0" AFF AND MOUNT J -BOX AT 8' -0" AFF ON WALL ABOVE DISC. SWITCH AND CONNECT TO BALER 13 EC SHALL ABANDON EXISTING RTU. REMOVE ALL EXISTING POWER AND CONDUIT. ABBREVIATIONS: AFF AHU BRU EC EF EMS EWC FACP GFI GP IG JB LV MC MDP NL NIC OC OSI PC RGC RMC RTU TRU UH UNO WP W/ ABOVE FINISHED FLOOR AIR HANDLING UNIT BABIES' R. US ELECTRICAL CONTPAM -OR EXHAUST FAN ENERGY MANAGEMENT SYSTEM ELECTRIC WATER COOLER FIRE ALARM CONTROL PANEL GROUND FAULT CIRCUIT INTERRUPTER GENERAL PURPOSE ISOLATED GROUND JUNCTION BOX LOW VOLTAGE MECHANICAL CONTRACTOR MAIN DISTRIBUTION PANEL NIGHT LIGHT NOT IN CONTRACT ON CENTER OWNER SUPPLIED ITEM PLUMBING CONTRACTOR RIGID GALVANIZED CONDUIT RIGID METAL CONDUIT ROOF TOP UNIT TOYS 'R' US ' UNIT HEATER UNLESS NOTED OTHERWISE WEATHER PROOF WITH \✓ BAILER MDP - 50, 52, 54 COMPACTOR MDP - 49, 51, 53 ■\ m N rommaly 40 ... RTUL'.- ; _ I I t% J. MDP - 31,33,35 ;, 1 ` L i r- _ `. 1. �-LB -13 - j HA - 40 1 _ -i 1 Tr L. ! r i. 1 I LI, j 1 1 i—? 1' I 1 I l ii 1 RTU \EL- L fi I ri 4., ;I: 1 1 -°f --n- tl!. I �- L- 11 1. LA -23 L _ I ELECTRONICS PRE-SALES 121 11101411 PSALES -,r —i 11 _L 16 LC -31 I -pPr T I i I a _a_ " / / / —r. / J / / / LB -22 LC -26 � p 1 Y 1 J / / f - -. l I I j i I L - L , LA 21 :- i i I r,!a. w 1•I Link 10 - MDP - 26,28,301 / M r 0 I-IA -36 (s) LA - 17 LA- 19� RECEIVING 84" - I.. LA -17 - 60" 120 11:,1 LA 19_C 15 84" CW:) -$AQIK "SIDE OP 00L`1JMN FA IL w I _- 1 I i r'T -T1 1-:,- - - • 'sue rr{ a-- � I 1F- Hit 1 lam,' [1+0 ,t 111111 j R I I RTU 0 61 -6" LFI ,'-:H -A BFI 5 i,VP L ^-Jy 1! 'C'7 r' -r n 1 ESACK SIpE OF CC$L MN Fib ING REAR WALL 1 ' II ' ' 1 1 1 EIS J RY VESTIi3ULE 1 402 /'i f /f /i` /I % ,/ / ;'''i I i -7I • l�'., ..vim < € // / I0T , 1 Ij 1 C 1 aA I I I n 1 E201 / / _I I 1' li IL LJ -- I- ' i 1 A ' # i - -1 _ N M 1 1 Jg fi; .L�II -r, II P--S 1 I L LA -21 - -; GFI I T- IS ;� MDP - 13,15, 17-T--7"---7-----.171 __SALES % f / •iii Ir— _. ' -ii +��►REA�1 _ / • ,i\ 11 ! _ �I 101 / I' / ,/ , / ill /11 !- ! 6' -6" r..- J _X LC - 2 1 ,t- T 1 -_.e- 1i I'/ Fir —7 TA • J -1 • _1 1 • I -� LB -5 • i 1 %; � GEL MDP- 19,21,23- i 1MDP - 20,22,24 "LD -2" & "C -2" "LD -1" & /1\1 EMS CABINET 150KVA X -FMR "T -1" MOUNTED ABOVE POWER WALL \ i\ ( 3) "LA" (SECTION 1) "LA" (SECTION 2) 111J /1 4 - 111/'1( A _ I \NN j MAIN SERVICE ENTRANCE "MDP" POWER WALL KEY PLAN SCALE = 1/8" = 1' -0" 1 WM NI e*iltif t a OTANOTG:O 1 3 1 LA -1,3 1 • !i_ii_I: LC - 1 • _ O IMGirretliro 0 p EXIT VESTJBULE-.. LB - 1 7 5 '75 LA - 5, 7 57 ELECTRICAL POWER PLAN E101 / SCALE = 1/16" = 1' -0" e.p IC � %1 7' I I> 11,, 1617- 11 / BACK $11YEIOF OLUMN FAAAAA.pN REAR - WALL -- 1 -i. �/;Y WP lig GFI A6 SPRINKLER RISER . 110 PLAN Jai • MANAGER'S OFFICE 111 TRUE NORTH COUNT ROOm 112 PROCESSING ROOM 106 BIKE LIFT BKE LIFT BIKE LIFT BIKE LIFT 'cE LIFT NNW EQUIPMENT ROOM 107 FILE COPY Permft No. SI-10 0(10 Plan review approval is subject to enors and omissions. Approval of construction documets does not authorize , the violation of any adopted code or ordinance. Receipt of approved Field Copy and cone*. is is acknowledged: Date: B:citYLD/ ING2;;Ibitwnao(ivIsin REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 1 9 2010 ‘11. (14( ity of Tukwila BUILDING DIVISION RECEIVED MAR 1 1 2010 PERMIT CENTER EL1()-0196 r CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION I MI 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE 0 10/28/09 DESCRIPTION 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE ENGINEERS cgc CONSULT 923 MAIN STREET, N. WILKESBORO, NC 286 PHONE: 336-667-4225 FAX: 336-667- 32 NTS STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA WA DRAWING TITLE ELECTRICAL POWER PLAN SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. E101 AR - CONSTR. DOC & REVISIONS l �.� �\ (.)) (\ ` Eii) NO. DATE DESCRIPTION �� 02/26/10 ISSUED FOR 90% LL REVIEW 03/08/14 ISSUED FOR BIDS & PERMITS ARMORED CABLE (TYP_) 1/2" CONDUIT TO DECK JB 4 "X4" MOUNTED 12' -6" (TYP.) DIRECTLY ` ) ) ` MOUNT RECEPT. BEHIND FIRST FIXTURE IN RUN. BEHIND THE FIRST I FIXTURE IN RUN. I �- EXTEND CIRCUIT TO RECEPT. } r ` WIRE SHELVING �� ( � -- - - -�` -- �- -- --`' .{•'�' i T AT STS MOUNT B � E - -- WITH ARMORED CABLE tea _ 1 11 it I; -1 - \1__. _ P 1 ; -_ -_I ( � i i1 jr ii ( �' � ... .I ii ,; -- f■ f 3r -sign' r�lc+14l III I a d e 1 I ' ' _-- -- T!il L�� `, Iz�° ,�. ;II `I IT I Il +Y9 - fj�r ^i „ U _- . 1 �— - 6 0 STARTER _ ., CORD ( BY OTHERS) t ? _ ; 1 - ,► ! L�_;,,! 1 Y ,� 1 . r r J T = Lb2 - 6 -- _ _� ; - __ LD2 - 9 i I B�r� �' 1 ill_ j ! ! ! ! I L , j L { I • I 1. •. t C I 1 iA..I , ; L. - g, ' ' el -F IF III. I I L, j: , _I� -1- • I r - 1 -: :. T 'T i L L , / ;i - 1, f.. -_: 4 f ;--� i �, i ! { T' r T I 10 I '-! _ f ..._ ... Jd= I. ? 18 ) ' n �^ =� I; JI lil w ;, VL .. VL VL VL VL VL ■ ( - i .. -. p ' r I + II ! LD1 :ice -13, 15, 17 1 ( I J *1: i 1 : :4 1 ! hi VL VL VL VL VL VL VL VL VL VL VL VL VL VL VLI '. l i B ( i = i'1, 4'b' I i 1' e 1:1; -' .-i j ! ! b: 9 i 1. i ! r- p i VL ii 4 ,: L .. _ j i me - II = �� VL VL VL VL -;:�I !ED �I' - r— _ - . i� ! d ry �._ i ,I j Ili I I II ;i _ . S 1 ._. 4 _ LD1 7 i � ! LD1 - .- ; f i j - ; 1 6 I I 1'' -... 1 T- Iv-i -� ' _ i ,� I! 1 ! I E. i i n 1 ;i I I 1 VL 1, �,` VL -; V _. 1 i VL t 1i r ► 1 !- 1 0 II I—_ L PROVIDED I I I !I i I - I L- j (7 ; N ! I :- i y r --^ i r- I i INSTALLED BY OTHERS. I' 4- i' I *� _ w L r 11 L VL I t --R1------.1 — n =-4� (20) FIXTURES MAX. DAISY - CHAINED. TYP. LOCATION " r w . iM 1 llw= _ - 1 ( II-� I ( I_ - I '� VL 1 I w i �_ — �= is f` I 9 1 . ! II __' _ LC - - =ter— - ~{ i` ; j ;I i ! I t r, iii I;. I to ; 1 , i l I 1 I F • j i I I: ! ! li 11 VL ! ,I ... - 34 - �•�- --� -- — __ �e� ; ; I e I LC - 34 as - . I , 4 i r I _ __ _ lad r - - 1- �'1. - - - - �3 -1 -:1' - -1 _ � F - ell - _- 1 X11 b _I 1.-7-7 - - — ---- 4�- -i-- -� ,` j = - ._ �. {. BEAM LIGHT • - I i ;i ! j I - �,_5^ i -10^ i - +_ " s ! -- � � 1 i I j `� PROTOTYPE UPDATES I ^_� V LD1 - 7,9,,1 VL VL VL VL VL 1 ; I ; I 11' i j LD1 14,16,18 _LQ2 ! _ _.j RECEPTACLES FOR VALANCE LIGHTING SHALL NOT BE INSTALLED ON RACK OR GONDOLA UNTIL FIXTURES ARE IN THEIR FINAL LOCATION. zs -7^ _ i ! { I LD1 -2 4, 6 I LD1 '� - -20 22 LD1 - 8 10, 12 36 �, l ice ' _ 3 j I ,.- VL r- \ - -- = i i 24 _i I I I ! I NO. DATE DESCRIPTION VALANCE LIGHTING LD2 -1 EXT. SALES WALL! CC- � l LD1 - 9 - _ -! i jLC_ I [Io 1 ! ; , _ -- "1 i-r... ,;-- - __ I . u , T 1 VL ' 1 aI` °1 I n I .rI, -... t� -- - - - -'}._ �i. ::.M1 � t� _ - ` - ". _ - - -- - - i i . _ 71 , -8 - ' . 0 10/28/09 2010 58K REV_ 0 z 7 I - �-t { i' tA! Ir - -.� 11` , I--- VL VL VL VL VL VL VL VL I + _� - - - - VL VL VL VL VL j VL VL VL VL VL - �✓ ( �.,•. ^•� I ► !` i , -II -I I �1 1 2 SYSTEM Ij rf — 9;. _ _ i LDS 11 =j '°�" 1 % I E103 SCALE = NTS LC -36r i LD--__ F110 0"i I a T,`,a��re -fib - _� - a� - ? -"- r il, Lq1 -4 1 - � ! ` �•; c N LD1-20 1k is 4`. ' _- - ---J 4-- ' - - ,r 1 T1 VL VL VL VL VL VL VL VL VL VL VL VL ! T I 1:, -- --1 ' s - --- -- ° �i::i \i, �� -6 LD1 -14 ! I _. a �/11 i _ :; � _ I l II, I I,T_.__ - I, IT :� v LD1 7 : + ; *r ^ - i. T:.. D1 12 LC I �11 f - _t i I i -i + ! �4- -"�,I p la i C LD1 -16 :i I n u A�^ . LD1 - 24 - , n: �_- �tmom+'_.. _,G LD1 - 8 I -Ir- 1 11 , : ! _ - POWER POLE MOUNT TO JB, VL VL VL VL VL VL 1`; LI W. r_- ', 1 l �� ?;- _ _ ` + �, s ';n h �U �' << 1 1 ;. LD1 .i _ - 2 , A! _i ei -. .. t CENTER / TOP OF RACK FURTHEST FROM MAIN RACE TRACK 4'0C4" - - I - ' is 9� 1 I 1 ,t I ! - - _ ■r , _ _ D.., D I l ;. I ' i _ -, T 1� -._ -, - ! 'l': i'�L__ - 4 _� LD1 I -18 m i !' { : 1' - - - -- 1 !_ �., _ 1 "� -=-� 1 VL a- VL - - - - - -. �.- -- - - - - -- ;, ; ; - y I ��1 AL I _ _ _ w� ± :-___.L. all - -!' i LD1 - 20 r l I :ii;„ I il- , i i JB MOUNTED ON CENTER OF RACK FURTHEST FROM MAIN RACE TRACK ..0 �.� 1. 1 is ( LD1 c ::(_ .� - -J;.- - LD1 10 1 I_ `Li CENTER AISLE �� �� (RACE1Rq _ _ f� 1-- -- - G- - - 1 i ° i I --1 - _ , .- 1 - = {:1 -14 I 1 ,s I LD1 r r7 1 a •. . ! I I k ! p I z LD1 - 22 ARMORED CABLE TYP. (TYP.) MOUNT RECEPT. BEHIND _����i I �� � —� i iI i� F I ! I 'r -+ , r NI; , I, i +�� —� — - -r _ X903 VL VL �� 4 LD1 -16 1�� _ = _� FIRST FIXTURE IN RUN, �/� '�' - CENTERED ON INSIDE � � • �� _ ,i c ` ^� W 1' VL VL VL (- _ % � r m �i + __ •,' ors .� i � - n.® _-- �- VL - i ii ;: VL , � LQ1 - 9 I 1 I - i I 1 _ � _i ! Jt E't03 a LD1 - 6 - LD1 24 - -9py —. —r o : • t I i '7�1 �, ` •. {�1 LD1 I g ii,� -12 \__REAR / � -I �} -- - -- -18 • RACK. r<_ _ TO FIXTURE ON ADJACENT w ) - - "-" i �, E I 0 LD1 ! ! I - �i I _ ` i'. r Im � \ � '� - 2 /4 //�j VL 1, ! I ',' LC i u li I' ei— !! tl LD1 - 20 _ ,._ ---- -' - 8 ' _ w LD1 6 STARTER - 34 ! — -0 ;- it I I ice' ;_ Li 4 � I i V i LD1 -14 h ETFR CORD (BY OTHERS) VL ! I Lc,'-., - 1 1 I -. -- `:Y ! IG <� I l . L-_ ! I i 1 II f it I, LD1 - 22 i 1 �.:. S I ! , : iz =1i' f I , '''"'i' is SI: _. ✓ la> �yL L�1 -4 ?, F_- �� T - y . %7 r x °' ' VL VL VL VL VL VL 1 .� �LD1' -16 �y I 1 - 1 -.1 -- I 1�. !i 1�1 L \ 1': VL * C I_. _ ! �, — t ((f qq ST ^," 'r /� :I `!° 1l i _I - - ~I •�— '� `I �� . , \; u. °" ° °�i _ .� • ��I LD1 11 & E . I : ,;I - l,/ .,!, --- -day E I 1, I _ — —Ir- ; I F 1 e, y6� _ - / I I i I i VL 1 1 ! ± I I I ! `�, WIRE SHELVING VL VL VL VL VL ' i (�LD1 -18 U - l(_) — I ! I j I LJ36 !N ' ! -- i \ I- ___ i i I j 1 ! j ' LD2 2 - 1: ( K 111 (PROVIDED / INSTALLED BY -- - - '- - -� LD1 -14 R I 'I BID DATE: 03/09/2010 PROJECT NO.: 55252805 ; LC - $4 I ! I -i 1 y F70. ! I ! I - -_I I I: l` - - k � J VL I .�. VL 1 VL ( �'' 11 ,_ jj ?—,I— s ;_..l_y *4/A'li I ; !, f 1 ' 1 ; I I I l F I ( 1 1 1 1Y I ' ! ' —" • Y i , t ( 1- LC - 34 1= I 1____.i,_ : I A J_ = ' � � OTHERS) _._. . 'VL PROVIDED / INSTALLED BY OTHERS. (20) FIXTURES MAX. DAISY- CHAINED_ (TYP. LOCATIONS) °.i q-- 11 j- ,i I_J 1 1 1 1 �-- 1 1 j •_1 ; I -f I '- l II -,l i f I V h. ( :U-- I f—.y= I 1 I 1 1 I I i ) , I II 1 ! it ! l I r -� r j - 1 = i [Al is I :�: !�'--� _ u`4 __ __ -2 I I [h '�>f 1 I ; I i , ll I t II %, C->:. -i - 1 I p.__f 11 I j 1 i I I i ! 1 - _ _ _ -- -16 - I. C. _. � ,1 � I J. ! _� �r___,. _I 1 • ii ! ; \� II I I (� !�� .i �' - -- I 1 I d r -k - �i ( 'j --__�._ ___' _-__- ! I 1 i II ! I I I i; I+ ! F I , I` ! p- B i LD1 ° % I` DRAWN BY: JJK CARP CHECKED BY: h-1 �..1 I _ i j ! I ( t-- I i - [ ! -; }" ,, -'' I i _ p 1 PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE pA,G �_q, :I: :i. 1 - � •i _� - m ; ) I i \ � , �- ��, 1 it ~ — LD1 r 1 I I.1 I I II i ! !���'1 =� - -- a1 I LD1 14 ° ° �i �� * -}:p_ ;wz 1 I . , I I I DOOR BUZZER LB - 7 N. f ; It s P Er-2-1 -� e_ 1 - -!=7�A -(TYP.) � ( _ 3,q , . L }� LJ'- :� TYP.) ter_ L::-.:-__, k ; L_4 ,, I q it ! II I I © I r----- ;� L :��' i�b ! i! I !1 I !I I ! I ! 11 , 1 _I I _J'.__... - - n ® LIGHT" r- 1 = i 1 _I — i - _ . _ i 11 BEAM E103 ^; ice= f-}; r � \., X� _ D _ L 1 16 _ _ - !_ ;' -- + - -�..__ _,-4 F f- ' I ,^"' - -- -I _ �• 1 I i n�..�� �:.._ rac F r -T "7 , Imo- r , 1, I ! c .w r v fza • _ � � R�'V O Rf(�R _. ,�._ .. . - - � --- +- •- -� _ Ir- �+ i__t ^ --- :.I. + r" 1 1 ENGINEERS CONSUL ANTS 423 MAIN STREET, N. WILKESBORO, NC 28 =-9 PHONE 336-667-4225 FAX:33 -b67 -433 3 POWER POLE VALANCE `c , �� l i; J Lei' 1 I IIj I II -JI – i i (L II l �� �� 1 =- ��+ I 1 - - ) �f RECEPTACLES FOR VALANCE LIGHTING SHALL NOT `BE INSTALLED ON RACK OR GONDOLA UNTIL FIXTURES ARE IN THEIR FINAL LOCATION. I I I y a L��_1 I l 1 I( 1 — L ---_- I I; 40,e. t4. ! • r_ +110 h , / IN LIGHTING -RACK -._�_ ... ___ M _ -- E103 SCALE = NTS 2� (3� i4 6 16) 7 \) 8 ' STARLINE COMPONENT SCHEDULE . 4X4 JUNCTION BOX FOR 1 \ RACK POWER & LIGHTING PLAN PLAN NORTH �/ TRUE E103 SCALE = 1/16" = 1' -0" i CODE QUAN. MANUF. CAT.# MTG. DESCRIPTION TYPE *1A 32 UNIVERSAL STARLINE B60 -204 19' - 0" 20' TRACK SECTION TRACK SECTIONS *1B 4 UNIVERSAL STARLINE B60- 15-4 19' - 0" 15' TRACK SECTION TRACK SECTIONS *1C 4 UNIVERSAL STARLINE B60 -1014 19' - 0" 10' TRACK SECTION TRACK SECTIONS *2A 32 UNIVERSAL STARLINE HC -2 19' - 0" TRACK HOUSING COUPLER TRACK CONNECTIONS *3A 32 UNIVERSAL STARLINE BC -4 19' - 0" TRACK BUSWAY CONNECTOR TRACK CONNECTIONS *4A 8 UNIVERSAL STARLINE EPF60 -4 19' - 0" TRACK END FEED UNIT TRACK CONNECTIONS *5A 8 UNIVERSAL STARLINE EC60 19' - 0" TRACK END CAP UNIT TRACK CONNECTIONS *6A 59 . UNIVERSAL STARLINE CBM100C- L520D -4 19' - 0" BREAKER/RECEPTACLE POWER DROP TRACK CONNECTIONS IG OUTLET (PRICE CHECKER) i+ _ *7A 116 UNIVERSAL STARLINE RHB-3 19' - 0" TRACK SYSTEM MOUNTING CONNECTORS MOUNTING ASSEMBLIES I' II 1111.111.11 EC SHALL FIELD CUT POWER POLES 8 ABOVE BOTTOM OF JOIST. ELECTRICAL SCHEDULE: .._t POWER POLE ON GONDOLA FURTHEST FROM MAIN RACETRACK SECURE TOP -- WITH FLEXIBLE BRACKET AND SPAN BETWEEN JOISTS WITH UNISTRUT ISTRUT AS REQUIRED. DESCRIPTION MODEL # MANUFACTURER REMARKS QUANTITY' P1 25DTC -415 WIREMOLD 15-5", WHITE, INSTALLED BY EC, (OSI) 64 _ ® P3 PREWIRED D &P AL, INSTALLED BY EC, CASH REGISTER PP (OSI) 14 SECURE POWER FEED END UNIT TO POWER POLES FOR CASH REGISTER LIGHTS ARE ALUMINUM AND PROVIDED BY OTHERS, SEE E201: BUILDING STEEL THREADED NOTES' VIA 1. BUSWAY BY EC. ROD 2. ALL BUSWAY COMPONENTS ARE TO �'C7 ` ^' �� •6 .., p tir "' z 'r � w. 7 , , u ..r BE PAINTED TIGER DRYLAC RAL9001. COORDINATE WITH VENDOR " 3. CONTACT FACTORY REPRESENTATIVE: CHRIS VIGLIAROLO .' #EC60 �-- 1. JUN 1. JUNCTION BOXES SHALL NOT BE MOUNTED ON TOP OF GONDOLA. (TYP FOR ALL) 2. ALL CONDUIT AND JUNCTION BOXES SHALL BE CONCEALED INSIDE "SPINE" OR UNDER BASE DECK OF GONDOLA. FINAL INSTALLATION SHALL NOT BE VISIBLE. -: STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 KEY NOTES ■ # DM i I:� @ (732) 259 -3377" FOR FURTHER 1 INSTALL 3/4" CONDUIT FOR POWER, SEE COLUMN MOUNTED PRICE CHECK DETAIL AND GONDOLA DETAIL (TYP.) 2 PROVIDE PUSH BUTTON IN VESTIBULE ADJACENT TO DOOR AT 42" AFF WITH BUZZER ON WALL AT 10'-0" AFF INSIDE THE STORE. PUSH BUTTON SHALL BE - MOUNTED FLUSH IN WALL. BUZZER INSIDE STORE SHALL BE POWERED FROM EDWARDS #592 TRANSFORMER AND CONNECTED TO CIRCUIT AS INDICATED. 3 ALL VALANCE LIGHTING SHALL BE INSTALLED AS INDICATED IN "VALANCE LIGHTING SYSTEM" DETAIL, UNLESS NOTED OTHERWISE. ALL FIXTURES ARE PROVIDED WITH QUICK CONNECT, "PLUG & PLAY" POWER CORDS. 1� - SEE 5/E103 STARLINE INFORMATION — FAX (800) 260 -1506 M "-LNG SpP `�`"-� TRACK SECTION BUSWAY II t► END CAP DETAIL. "A" PHASE "B" PHASE 00'�y - - ' _ I WED FOR REVIEWED WITH COMPLIANCE W^I C NEV NFPA70 C� Of TUkWI�d BUILDING D �V�S�ON Ifs G J!1 "C" PHASE�f�'-- NEUTRAL I = 0 SIG - WITHIN 6-0 KELLUMS POWER POLE SECURED AND II ALIGNED AT SQUARE GRIP SHOULD BE USED KNOCK -OUT ON TOP OF TO SECURE WHIP TO BUILDING STEEL. SPINE. 1 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WI " �� GS WITHOUT PERMISSION OF TOYS "R" US. .. I #HC -2 TRACK SECTION " . I NEW PRICE CHECKER MTD. TO GONDOLA. FIXTURE FURNISHED AND INSTALLED BY OTHERS. IO #RHB -3 CONNECTOR TRACK SECTION 3/8" THREADED ROD HANGAR (TYPICAL) #B60 * *-4 �► SECURE TOP TO tkI1f;U, U- . -415 I /1■ IG -.. DRAWING TITLE DISPLAY P W E R A O AND LIGHTING N .. PLUGMOLD SCHEDULE. FEED UNIT . a , Y TU, Y EC. ABOVE BASEDECK �!+ ',/ h ,, OUTLET FOR PRICE CHECKER t� f SHALL BE MOUNTED UNDER BASE a ( f r DECK, FACING PRICE CHECKER. �`� ' QUANTITY MANUFACTURER MODEL LENGTH :�— #CBM100C- L520D -4 (2(2) 20A CIRCUIT BUSWAY (BOTTOM OF PLUGMOLD). 97 WIREMOLD #2000 GB SERIES, WHITE 3' - 0" - BREAKER BOXES WITH (2) UL TYPE SEOOW CABLE WIREMOLD #2000 GB SERIES, WHITE 5' - 0" TWIST LOCK RECEPTACLES W/ WHITE JACKET ON UNDERSIDE FACE (COLEMAN OR AWC) tl WIREMOLD #2000 GB SERIES, WHITE 6'- 0" PROVIDED BY EC. * *- / REC�'VE® . LENGTH OF TRACK SECTION ISOMETRIC EXPLODED VIEW I SCALE As indicated ISSUE DATE MARCH 9, 2010 5 STARLINE 1..7 U SWAY DETAILS 4 GONDOLA DETAIL COMPONENT CHECKER RECEPT. MAR 1 1 20�U SHEET NO. E103 E103 PERMIT CENTER SCALE = 12" = 11 (�11 SCALE = 103 /'\R CONSTR. DOC & REVISIONS l NO DATE DESCRIPTION DATALEGEND is GENERAL NOTES: �� /~ 03/08/10 ISSUED FOR BIDS & PERMITS X CALL BOX ANTENNA / RCU TRANSCEIVER - PROVIDE (1) CAT5e TO EQUIPMENT ROOM. 1. EC SHALL PROVIDE ALL ROUGH -IN LOCATIONS. EC SHALL CONTRACT WITH TRU NATIONAL ACCOUNTS VENDOR TO INSTALL ALL LOW VOLTAGE WIRING FOR SECURITY, LOSS PREVENTION, SPEAKER, AND IT SYSTEMS. INSTALLATION OF COMPONENTS AND FINAL CONNECTS PROVIDED BY OTHERS. SEE SPECIFICATIONS. 2. ALL LOW VOLTAGE CABLING SHALL BE PROVIDED BY TRU. _ N 3. ALL CCTV, SECURITY, AND IT CABLING SHALL BE WHITE, PVC (NON PLE UM RATED), AND RUN EXPOSTED (WITHOUT CONDUIT) IN A NEAT APPEARANCE. EC SHALL VERIFY THAT PVC CABLING IS APPROVED BY LOCAL CODE AND THAT CABLES ARE NOT REQUIRED TO BE 100% IN CONDUIT. 4. ALL EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. 5. ALL SECURITY EQUIPMENT SHALL BE CONNECTED TO EITHER MAIN BURGLAR ALARM SYSTEM OR BURGLAR ALARM EXPANSION MODULE, COORDINATE TERMINATION POINTS WITH LOSS PREVENTION MANAGER. 6. ALL SECURITY WIRING SHALL BE IN CONDUIT UP TO DECK. SECURITY WIRING SHALL BE KEPT AT LEAST 1O'-O" FROM ROOF HATCH. 7. ALL CAMERAS SHALL BE TERMINATED AT THE DVR EQUIPMENT IN- MANAGER'S OFFICE. 8. ACTUAL CAMERA LOCATIONS SHALL BE COORDINATED WITH LOSS PREVENTION MANAGER. 9. MOUNT ALL CAMERAS AS NOTED ON PLAN FROM BOTTOM OF DOME AND/OR 6 TO 10 BELOW THE BOTTOM OF NEARBY SUSPENDED LIGHT FIXTURES. 10. ALL SUSPENDED DOME CAMERAS MUST BE POSITIONED AS STATED ON PLAN AND SECURED TO BOTTOM CORD OF BAR JOISTS WHENEVER POSSIBLE. IF NO BAR JOIST IS AVAILABLE THEN CONTRACTOR SHALL PROVIDE AND INSTALL AN ANGLE IRON WHICH MUST SPAN BETWEEN BAR JOISTS AND PAINTED TO MATCH ROOF DECK 11. PROVIDE CAMERA, OVIDE 25 OF NEATLY COILED WIRE AT THE BACK OF EACH CA INCLUDING FUTURE CAMERA LOCATIONS, TO FACILITATE CAMERA RELOCATIONS. 12. WHENEVER POSSIBLE RUN MOTION AND HORN /STROBE WIRES INSIDE COLUMN, OTHERWISE RUN CONDUIT ON BACK SIDES OF THE COLUMNS. 13. ALL IT LOW VOLTAGE CABLES SHALL BE APPROPRIATELY LABELED ON BOTH ENDS, COORDINATE DESIGNATIONS WITH IT MANAGER. 14. ALL LP LOW VOLTAGE CABLES SHALL BE LABELED: TV1, TV2, DC1, DC2, ETC. COORDINATE WITH LOSS PREVENTION MANAGER. 15. ALL CAT5e CABLES TERMINATED IN EQUIPMENT ROOM SHALL HAVE FINAL INSTALLATION WITH 20' OF SERVICE LOOP ON LADDER RACK SYSTEM. 16_ ALL CAT5e CABLES TERMINATED IN IDF PANEL SHALL HAVE FINAL INSTALLATION W WITH 10 OF SERVICE LOOP IN THE PANEL. 17. ALL SPEAKER WIRE SHALL BE 18/2, WHITE. SPEAKER FEEDS SHALL BE RUN SEPARATE FROM ALL CAT5e AND FIBER CABLES. TERMINATIONS SHALL ALLOW FOR 3' COIL AT EACH SPEAKER AND 30 OF SERVICE LOOP IN EQUIPMENT ROOM. VERIFY ALL LOCATIONS AND ZONES REQUIRED WITH LOSS PREVENTION MANAGER. 18. INSTALLER OF ALL LV CABLE SHALL COORDINATE FINAL TERMINATION POINTS FOR LP AND IT EQUIPMENT. CABLES AT REAR OF STORE WILL TERMINATE AT BAX OR IDF, RESPECTIVELY, (T'•) INTERIOR SIREN - PROVIDE 18/4 CABLE TO CONTROL SIREN DEVICE CARBON- DIOXIDE SENSOR, CONNECT PER EMS-1 DRAWINGS. MOUNTED AT 66 ,. AFF, UNO. C 1 4 �5 ( C 7 \�i n INDOOR GLOBAL HUMIDITY SENSOR - RHS -1. CONNECT PER EMS-1 DRAWINGS. MOUNTED AT 78" AFF, UNO. A = `% I �/ �J `�� ,- j B ` j'T i!• !I 1 II rrr _ _- __ _ __ SENSOR FOR ROOF TOP UNITS. MOUNT AT 6' -6" AFF, UNO. oC -20 " 1 e O 11 0 SP ® SP _19- P -1 Lir-7:CE w: L BAX C-8 , _ 11- 0 -- ®` - - T' -- - sP SPEAKER- PROVIDE 18/2 CABLE FROM EQUIPMENT ROOM TO SPEAKER LOCATIONS VERIFY SPEAKER- WITH SPEAKER ZONES REQUIRED WITH TRU PM. ',' -'L sP IF RCU #3 nf HKUCCRW11911MMIWI ^. 391tl MIIMI11IIMIRkE�IP1VRIII �$ r , rtT I ,y.�- ; • J., �!'_= ' r� X sP U ii ! _' 3 RTU -11 SENSOR I ---ii-1- "i' PAINING sP w - O _21 i i�11' - 0" I C-2,_- v O 42" VOLUME CONTROL- SPEAKER POTENTIOMETER MOUNTED AT 42 AFF UNO. � �4 '�C • S - - T 54" _ r-;r-? ------ k. I : h — r -- r-RbpM ! PD . f ! I ---- - =u�= _. °j - =,�• � -� .. :> �, I I � ., i �-14 �, ?' jl ; I ' ' I � �`- I I I , ' ` sp r , � :rfiu, &pMn�p a3RR,RnmCR�lwAORkwJfinuT" i �' 1� I �f I, � ;' ,, a =I, -- - k_____ '— RTU- - -- - - -- s , , r , I, A, I. -.` -- ,- -- - - - -- _ _ _ . _ _....._. _ - -- - _ 10- SENa(3- - - - 54" ' ___,I• -- ® s_.. - - - - - - - -- -- -; ----I INTERMEDIATE DISTRIBUTION FRAME- MOUNTED ABOVE DOOR. PROVIDE (1) CATS, (2) CAT5e AND 1 PRETERMINATED FIBER OPTIC CABLE FROM IDF TO SERVER RACK. {) COORDINATE LENGTH OF FIBER REQUIRED. �- � i i SP '! ��. ' - " � IDF c:, I ! '- _ _ ! ■ I !' b11.414Y , 6fl1aR119, 11NAP. WiFUN9 „1.lAWrlfll&'ffiIfRA19UMkfNSN {ngpiRml9wp4f IDF sa �- 9n -_t �.L.��_�:_.�__�,__.I:__._ : h ii � li I, , P 6 i I ;I -lil < L_,t� _' - A -� - � .; „� � L J. ' �._.;. - r- C -13 a,- '- O C -18 I I 1 ! (____._i i.____i__.__I__ ; !_- ! � ( � BURGLAR ALARM EXPANSION PANEL - MOUNTED AT 10 -0 AFF. PROVIDE 2 18/4 CABLE FOR ' ” (2) DATA AND (1)16/2 CABLE FOR POWER, TO BURGLAR ALARM PANEL. I ;_ ( -. ;Q II ! RTU-1 SENSOR U ____.s. e - ■ r ..` __. =_ wj =_: , -_ „_, BAX G9 ! r-? RTU -2 SENSOR t �- VM �-I ,, r.....7.-1 I - _ ' i r I u 19 - 1�,1 g' - p� �- l - Ti- . ' i d ! ' 1 �� I ! !-'1 I ' y� �� ; + ; ,___2.: � '_' ; !` it IP -5 I ” sP '� (. --�.-_ Y�i FII.'; i I. I I ! �' . L � I r '! 1 i I ' ! -' , ! ! ' ! q I ' gp I .'il - -i h I I I -I !I ! j w j 1 I al- I ! i i I �, i i ;r ;' __Y-. !! ; , I ,. =�- ! I_ ®VM I L i ! I„ .�1 I 11! 'Y-` ! } - -�"_ -i-1,-, I I I ! - _'L- -• I �r t �,: ' sP p i it "� ! ® T_ - MOUNTED AT 13'-O" AFF UNO. PROVIDE (1) CAT5e CABLE_ DOME CAMERA - FIXED MOON O i -� _ Q.... f sP - I11 I( i__- �Q- , I y, , ! y� „ I j _. ! �-i_ - P i I , l ;i !; fi , -r i'.1 RTU 5 ;SENSOR - �'! �— I' , ,ice I Ii �..__-,,..- II 'I �I___} I j f I I j T ZL I4-- I I i _ ; I -�{ ' i I - I il- - �( i P- ; i �L �i i I II I! �� 17" .. y I 1r f E-i VI E 1 CAT5e CABLE. VIEW MONITOR/ CAMERA MOUNTED AT 9'-0" AFF, ONO. PROVIDE O COORDINATE LOCATION OF DECK MOUNTED RECEPTACLE FOR POWER. ;I ,I I ! , I ;, __L. i r; PROTOTYPE UPDATES I -i- -� F..4.._ �L___,i j - -_ ! it I �� I i -Ij-1 1 -- , s- z I ,, ; -1! --W ' - ._, I ! +.' - - -- j i I '�' - -� �' I r '! -� � , ' - -� II ,. (I `� I- !I 1 � � -,. _. -, I j _ I I. ! �� r �= '_.'. N ! l i i ! ii I I _� 1 I! -fi - 1 �_L - I NO. DATE DESCRIPTION RR u O WP WEATHER -PROOF DOME CAMERA- MOUNTED AT 13'-0" AFF, ONO. PROVIDE (1) CAT5e CABLE. O �_, �L I ' I. r: I sp �--- ■ I 0 10/28/09 2010 58K REV. 0 _ =- ,�r�,el >� . \ ; %___ �; ���; :60 __ __ ! � I -` -..1t� � ,�I- �� � �I � �! ', � C -12 „ 9 -I0 sP j ( � I ! � � f6 : ^-� �! � !- � I i ' `� � - � !r�;�`' • 1 - !' • -. 11 -_:-� ��_�,;- , � __ ! _ --� --1 j I I 1 1 ' I CM CEILING MOUNTED DOME- CAMERA MOUNTED TO GRID. PROVIDE (1) CAT5e CABLE WITH 10' OF NEATLY COILED SPARE LENGTH ABOVE CEILING. COIL SHALL BE SUPPORTED BY STRUCTURE, NOT LAYING ON CEILING TILE. sP ; I -� •__ -- I sP I � ! ! L______; C-1Q 9 - ., - -- ! I I _' ' � I i I sP I I - ( - - j- _ ,I i - -1 - , I ! - - sP �� ! ►� W-4 CI PD CD ! �___.._ ! ! _. 4-- -� � r , ; C- Ij , ;� y ,_ _ __._____� I -_ L________ �___� \ ' � } ; 1 I I I • , ;_ -,-- - - I I I I ' I I I � ! i_€_1?. L ® PD ., PRE -WIRED DOME/ NO CAMERA- MOUNTED AT 13 -0 AFF, ONO_ PROVIDE (1) CAT5e CABLE. -17,717 �`�_° `-°_`; �L _ °', - - X - - -_ ) i E -- Ij I,_�I. 17- p I � �r L rF. z y- -gi'— " ��..:, -•i, �� �L ., .._ L� � Ir° 1�_` RCU #2 `_�!i� ! ,� > L _ \7 m -i fi i _ ,'r��l --' :. '`�'I � - - --�� -- �'--= �'- - -�� .il -- - '�- - - ".!� ;,�`°Y,! = - u -_ �. =- ,• � __ mow_ L j- P -7 _ ! r I : - �. T- - F FUTURE DOME/ NO CAMERA- PROVIDE (1) CAT5e CABLE. ! ; < � 1s -. ("•> ('w''�, r-�� I��� ! I <. � /j, j L:>i - - 1 ! I r -- ( "- ' L ! ,i ^' : — I i � -4 I. ---1 I I -; iq ; � - !��_� � � r-' i �- �_•� `fir=" ! :. —W 4j SENSOR • ---� RTU-A3 FIT I I I I: i! `. 4 ny I�� I y �-�'„ -, �' '� r IRI STATIONARY CAMERA/ NO DOME- MOUNTED AT 13' -0" AFF, UNO. PROVIDE (/1 CAT5e CABLE. l ) ! I i i +i, �1--, l-� !` • i : ! . �, _ " _ lJ_ _ - I I ' 'i �'j _ �-� ' 'I I I ' ' Z ' I j I I ` ' I , % 7 �' I C-5 ® I ❑� I � • �i - I ,I e..�+)_ _ y L— � � I ( I ' I i 1 I � � i I t� -= =( I �_, _ ..G��i Grp 1 ^r.. �, � ; sP 6 ,a� v -, =� , r f b �: _ �1.� / � I ..L_, - `I -� .1E3!' ,i --., --i !- DI 360° MOTION DETECTOR - MOUNTED AT 13'4)", ONO. PROVIDE 22/4 CABLE. sP L___________ I sP — — SP ! -- i -^ (�_ i L ! 'g � 1 �"f -tea r:_ij sP sP I ! I--11 - E ® sP r N� \' ; ! - _ S _ — �i-" - P RTU -F�1 -' SENSOR F-----1 • i {- a- —Li! i ( -, , 9 0 ,. - - I 1; ? I ti ._.s _____1 ; i ti ui 1_ �, d 1 - , N. SHORT RANGE MOTION DETECTOR (60' RANGE) - MOUNTED TO DOOR CONTACT JUNCTION BOX, 6 ABOVE TOP OF DOOR FRAME, ONO. PROVIDE (2) 22/4 CABLES FOR DOOR CONTACT L� - - ; \ I, i I ( -T ,! , _ 4 'F t .I - -___� 1 L�_J, - - I ;� S C ± �jl - --, � L - -_ -\ -7.- i 'd! --j'� _1 - - i `� i�_,a_ I ! I � � - -- - - -Y- - _,(_ I � RHS-1 �, - - -- X �-- ■ # KEY NOTES # �� L^ h! � � __ �i �I I � " � " _i _: � - `-- I I SHORT RANGE MOTION DETECTOR (35 RANGE) - MOUNTED AT 9' -0", UNO. PROVIDE (1) 22/4 CABLE_ j - �-B -#2 - -- E202 � ! r- G- B- #'I-,' -- ;r j I I i � a - -- - ' �' `'- -'!- w!- -i ; - j. _ - ^ I i - - y ; I L % ` ! ! ST -1 © � T- ;� 1 PROVIDE SURFACE MOUNT JB AT 6" ABOVE DOOR FRAME TO CENTER OF BOX, F " � O OR ALARM CONTACT AND MOTION SENSOR, PROVIDE 3/4 CONDO AND EXTEND CONDUIT TO DECK. LOCATED DIRECTLY ABOVE STRIKE SIDE �� L i - V V D TELEPHONE OUTLET BOX - MOUNTED 60" AFF, ONO. RECESSED IN WALLS FOR ALL LOCATIONS, EXCEPT PRESALES AREA. EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. PROVIDE WITH 1 CAT5e AND 3/4 CONDUIT TO JOIST SPACE, INSULATED BUSHINGS AT O BOTH ENDS. DATA / TELEPHONE BOX - MOUNTED 18" AFF, ONO. RECESSED IN WALLS FOR ALL LOCATIONS EXCEPT PRESALES AREA EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. PROVIDE WITH (3) CAT5e AND 3/4 CONDUIT TO JOIST SPACE, INSULATED BUSHINGS AT O 3/4" BOTH ENDS, ONO. DATA BOX - MOUNTED 18" AFF, ONO. RECESSED IN WALLS FOR ALL LOCATIONS, EXCEPT PRESALES AREA. EXPOSED CONDUIT SHALL BE PAINTED TO MATCH. PROVIDE WITH (2) CAT5e AND 3/4 CONDUIT TO JOIST SPACE, INSULATED BUSHINGS AT BOTH ENDS, UNO. 3/4" - � I sP _ i _ ! r-----1,-1-74 ' I °i �t><•, ,� , .� s , t_;_' "1 _ -[J "i - f 16 `I-- € ! RTU -A2 SENS61� �19` � L - =; � sP O � `� � Pte_ �� ,°�_ � ( I sP , � -. - __ -__ __ \- -I� � r.- J ---,74; ! , T -O � i-.- " , i ;L , ;, --•� _ �% "___- L_�� >� � i � i f--'-', ! OF DOOR. 3 DOCK DOOR CONTACT- PROVIDE JUNCTION BOX, 6 AFF, WITH (1)18/4 " CABLE, 3/4" CONDUIT TO DECK. 4 ACCESS POINT- MOUNTED 15-0 , ON BACK SIDE OF COLUMN, PAINT TO MATCH PROVIDE WITH 1 CAT5e AND 3/4" CONDUIT TO JOIST SPACE, O INSULATE D BUSHINGS AT BOTH ENDS. 5 EAS PANELS- PROVIDE (1) CAT5e FROM COMPUTER ROOM TO CLOSEST EAS PANEL. PROVIDE 25' OF SERVICE LOOP INSIDE EAS PANEL. FINAL CONNECTIONS BY EAS CONTRACTOR. 6 INTERIOR SIREN- PROVIDE 18/4 CABLE TO EAS SYSTEM. 7 INTERIOR SIREN - PROVIDE 18/4 CABLE TO BURGLAR ALARM SYSTEM. 8 EXTERIOR SIREN- PROVIDE 18/4 CABLE TO BURGLAR ALARM SYSTEM MTD E202 - I -_: I! Ia1 ��- ;I I( - �i 9' - 0" -i---k--1 I' - ! I E I \ ` �' ' fie.. ; (' -� � �'�,'` = !" i I �-� 4 ! I I I ' N ! , I i _ �, � �-- °i _ �g � 1 F % �« L - S i - t �' �!' ' I '' ° I - -J i ` ! I J iy ' f s ___J (" } I I j I '` ` , E ! ( ,�-,1 ; •, L: _ ! - '- ' --j-¢ , i� --i `? _; i ti':,- I I PD r �^ j I`- r - , � j %' ? - �- �" ____r __f_ !o -- �- ! ; � -� I ' ; . �_„ � t I' I g I 1 - „ -_ - _ �_� - r-�—� ; j i _— — _- q._--�� _. - ' '�L ' w„_.. � -- �, - � ! SP 1 ! BID DATE: 03/09/2010 PROJECT NO.: 55252805 �— j" I I � I r- -- - ! , W ! j �' _�i' - r _ -r F,�1 -� n -� T Fil r----T1 1 ^\ IL, i 1 -� t r� -- -- — —. I Ni (�I C�1 I l �_� ] iT�l [._.L ! I - _ ;, I _L._ i �.1--—'IL: '- _ i -ai I , ! ° II I ! r,_ _ +_� .� j i _ E -_�I r - \; 11 . t � �, .I. .I 'l ' �; ! L) SP P'8 I - � SP � I -- r_____ � �- �- -- ! SP ! - - -! r z � I % SP ��' , SP I I I S I I SP ! I I I � q - I -�� -- � -- �, - SP -- 1 -- - °' `y DRAWN BY: JJK CHECKED BY: CARP ' '-` r PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE .24'-8" AFF. VERIFY LOCATION WITH LOSS PREVENTION MANAGER. 9 PROVIDE (1) CAT5e FOR ETHERNET CONNECTION TO EMS. 10 PROVIDE (1) CAT5e FOR ETHERNET CONNECTION FOR DVR SYSTEM, TO TELEPHONE BOARD IN EQUIPMENT ROOM. 11 POS LOCATIONS- RUN DATA THROUGH UNDER FLOOR DUCT SYSTEM- COORDINATE FINAL LOCATION WITH FURNITURE INSTALLERS AND TRU PM. 13 KNOX BOX- PROVIDE (1) 18/4 CABLE TO BURGLAR ALARM SYSTEM FOR „ TAMPER SWITCH AND 3/4 CONDUIT FROM KNOX BOX TO JOIST AREA. COORDINATE LOCATION WITH LOCAL FIRE MARSHAL. 14 EMPTY CO X DOORBELL, CONDUIT AND JUNCTION BO FOR INDYME SYSTEM DO MOUNTED OUNTED AT 44 AFF. 15 SAFE- MOUNTED AT 48" WITH 22/4 CABLE TO BURGLAR ALARM SYSTEM. 16 GLOBAL SPACE TEMPERATURE SENSOR - ST -1. CONNECT PER EMS-1 DRAWING. MOUNTED `--� ►�� - ,8 E104 3 I I , i F3,"U I ( I- ; 6 � rt { ! ! ! i I RCU #1 I I_ ! I ; r O x-23 -t L Z ' j -- -3 SENSGtR _ -� I �� � �.�. --�- �---'- ■ --*_— -: -- _- • • -, - - -' d _ ii ;I ""- -' , j !� - f - -, I� Sp O C-- �= ' � � I k -�, ✓r=i II - �'� -�i -,9 -- 1-1- �! 7 t ! I � jI I I� E1-1 I ; I 6 � _ = ! I it , ? �_'� ! F- z -- j ---r - ! �! - -- � I , ! I � - -- ITT ! \ I F '' =il- - ,t - -T.�- -" 1 I--f- `! jam- T 'r=, __ � I b � rIL__1111-E 1 I •� ( j I ,�� I �dl v ( , , _, i L ' � I I •: =� K (- �I ; i I ■ i Y • s `may r i '��I I i , I ' - -; ; ! , h:T ._ __ ; i- fI j I--L-;44- � 4 I � 1' r ; .I t ;�F- Ii I - I-I 1 1 � -! , -� C-2 "- } 9 _ ' I i t-{ h� I ,: P 1----4 r_7 I G �! ,�_T 4yi N;T- ' • ! r, ' I ! I i -i I -� - '!---- .;- .__,,_� ,� - - r r I !��' ! ! - j r i I I ;I�- i ! LI r ; : � I ; . `i !' I! !� j. $'•° +, 1 �.. _ ._. _ r - -.� ; ;_s� ; i ! . _.._ ,r•: r' • I - I ; i ;I ,i l I j I I �; G • � - c, Ada _ �`, ,� �� � �� ,�� F'� � I ;_�_�; r- ;:r-"; n ! I ! ., II I , ! I, I I 1 I ;`�. .I � I d �, � _Li, i: _._... -' � - - -- - -- ' i4..;-,i ;�,,I •,;; ! - -- L ---- _41-11--=-- I L • .Y�9. "�- 1....._ - - i> �_- .�_�f; _ - l��!- _ _ __ _ -- 1 -- -- — I� '- � � �r��� .. �- v C -3� I g' _I0' I I , - -- sP ENGINEERS &CONSULT ° NTS 423/v1AlN STREET, N.1NIL[CESBORt�. NC 28• ,- PHONE; 336467-4225 FAX 33b -bbl =4332 jl ; I ; ;; i i I I i i 'I I ;i '` + ! I' • �I-i "J -_ -- - -' I L'1 ;!_� ® � _ = - iG J ( !I i ' � ; I !! ' i �r EXIT 3/4" CONDUIT TO DECK, AT 78" AFF ONO. � 17 MOUNT MOTION SENSOR TO CEILING. 18 SEE E201 FOR EQUIPMENT ROOM LAYOUT. I 7 I Vc� VM _.1_____ -___ i' 11::_=,.. r - F i I o 0 I PAINTED TO MATCH. JB FOR MOTION SENSOR AND I i F -I L s� " ' ' .+� // I i 0 M11�4G / 9-- `.._ i i ! I ! i' r' ! Em ^ ! ? ; �___�! 1 171-----1 ' - I rte; DOOR CONTACT 19 SENSORS FOR RTU S SHALL BE MOUNTED ON COLUMNS AT 7 -0 AFF, AND ON WALLS AS NOTED. SENSOR INSTALLATION AND CONTROL WIRING BY EC. �� C�0 �b . " 17 - 0 Q " i. ' �,! ,_, i i`� !� I -- ; C� I" _ c ! 1� i REFER TO SENSOR MOUNTING DETAIL, F202. 20 SEE VESTIBULE ELEVATION FOR RUNNING OF LV CABLE. I WP �. ;` ! } a is —_ * I -1 —_:' ` I __ __ ARMOR CONDUIT AND CONTACT PROVIDED AND INSTALLED BY OTHERS. - �-, sP _�j W , �- -,.......1‘, - - -- - - -- - - ' - -' ti° 44-f I ; PD , = t -- , I SER � R C RACKS � BU, RGLARALARM SSfSTEM -�._ = - ! I I PROCESSING E104 J '. ® ■ ���� ,! f • trt ��' �, �J�* o i I I ` I (1) ROOM_ IRE ALARM EQUIPMENT ROOM a c -3s LINE �J 1 T - 0" ! WP �J 106 �� ,� C3). PLAN (iii) ® �. ) 107 3 EXTERIOR DOOR ELEVATION (TYP.) I �1 LOW VOLTAGE E104 SCALE = 1/4" = 1' -0" j � s o E104 SCALE = 1/16" = 1' -0" / E - C { r. I I r ! _.: II I;_ F Ii ! ,._w P ! I ! - =� I ! . i -I = 1 ! i f _:. P Q3 ED FOR REVIEW. CONIPUANGE 11VIT C FPA70 NEC 1 2010 MAR 9 LV CABLES TO BE RUN THROUGH { TUBE STEEL t Ij VM SALES AREA 101; C R C-36 eP ".-f...234' p P c -30 L--28 X26 w uR MOTION SENSOR- MOUNTED ON SIDE WALL ,. r O r I I 1 I; I I I r TY r . I I f x-$2 LV CABLES IN RIGID CONDUIT. -PAINT `,: •! !' 1C• -88 " . �� 116 0 1 0 , 4Ii 1. Q.. " " . f: I6�0 6 0 " 1 0 7S— 0 I " ,: a 6 drr -xa, JIp Vh �;✓ ., , ., .. _.�... � _ I .r'j.._ ..� `_. ,�'J71 I � ,I j ! v I Ti3 MATCtd� SHALL NOT BE I VISIBLE FROM EXTERIOR. I ` l; I• IF L_ I, i , i ' i a,,' � ,;2J D� X , y L G S f °^" c ,, i �, -`,a t I ' ! SP : ! { E'o SP i I` i � ;x' C STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 I MOTION SENSOR I MOTION SENSOR- MOUNTED ON SIDE WALL E292 ;' ; j I I , I I C-40 I I I ! ! ,I I - :; '` - 4 _....I 1 g _— �' -- _ - -- -- IP^ EXVT j P - -- -_=1_ - n �� Cam) . �C-31• _ ----- - - ---- --- - - - - -- . --- - - - - -- � -- -, ' � � :" It �; LI I, ;, ARMOR C AND CONTACT ;j PROVIDEDWVD INSTALLE I .' -, I 1 i i ; !r ; I E104 I I ; n !! Ij ! I ! ! `!- I , I I I ! 1 Iw - --' - - r �. I I RTU-4 SENSOR !. w, I i � I II I! rl II I II �I i —__' 9 i1 i i ii III H i ; ;, ! . ! I i1 III !; I ! I - ,. . 1 gil DUIT (!I ! I !l +1!I ' `Y '})i! I ! I ` iI ' I'li , :, !I !; a- II I' ;, (, ; ',: I " : ! i` ! ' I I I I I` = F �- ALIGNED WITH TOP OF DOOR {nP) :� �' u C -37 C-35 C-33 - - 16' -0" 16, 0„ 16' 0" 4 16' - 0" C-29 C-27 C-25 _ 16' 0" 16' -0" 16' -0" I 19 ! 'I I' ,! I � ,• II ! i II ii it .0 F202 RTU -8 SENSOR 60" THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED " " NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R” US. ( OTHERS. ' .I �(II! ,III' ,'� ,= 1. TU -A4 SENSOR 8„ © , I I -- .-, i':`, ij I CCTV HEAD END EQU "• r �- — — �J, a J _ —� • C-- _ 1 s r ' ; I5yl. �` l: ; i l I I i ! i „;I I I !Iii 1 • � ; I ,; I I I, I !- I C41 f .1 1 I ! I y ! I ® I ice — ; I ' 'III ! I Ni ,. I !. I 7 I I 1 I i I' (1 i I ;; , I 0./M. ALARK 54 SP LOCATION • it I' I ., I, , I I �\ --- ._.- - -- ----_...__..._ - - - `. �� I L! f �; ENTRY \ ; •f — p i7 •1 � II— EXIT - 1 H a I I I - 1 I i , 1j 1 _ _ _ -_ -- _ _ -_ - �_- K ----------111L--7! . ;. I NOTE: IV co ��_ L City ofTukw da RUN 18/4 CABLE IN FRAMED WALL, IN CONDUIT, ADJACENT TO VESTIBULE VESTIBUL ■ -._ - _ .. n-._._.. -__ 1 d �� VISION STORE FRONT SYSTEM EXTEND TO BURGLAR ALARM PANEL IN - .� 5. -- -_ _ _, _ _ . __©. _ _� I i L' UILDiNC7 DRAWING TITLE LOW VOLTAGE PLAN EQUIPMENT ROOM. SECURITY COMPONENT INSTALLER SHALL EXTEND OUT OF MULLION WITH 1/4" ARMORED CONDUIT TO 102 103 .' -- -- —y�_ • -" -` RTU SENSOR -- - COUNT ROOM CORNER OF BREAK -OUT DOOR AND FINISH INSTALLATION AS SHOWN. COORDINATE FINAL LOCATION AND LENGTH OF WHIP REQUIRED FOR INSTALLATION WITH LOSS PREVENTION MANAGER. (TYP. FOR BOTH SLIDING DOORS) C � /r /-- 1 -9 54" MANAGER'S �1 OFFICE J RECEIVED SCALE As Indicated ISSUE DATE MARCH 9, 2010 111 112 u MAR 11 2��o 2 LOW VOLTAGE PLAN VESTIBULE ELEVATLON (ENLARGED SHEET NO. _ PERMITCENTER E104 E104 SCALE = 1/4" = 1' -0" SCALE = 1/8" = 1' -0" 1 04 R c) CD T cn 1 _j- - ' U U._I LB -34Fm J J }�a •'.!i _ PLC - 32 LB -19 LC -12 i�L ti I LB -21 LC -12 LC - 30 ' MANAGER'S LC co J COUNT c;\ ROOM 1/J LC -14'? OFFICE 111 112 i�- i1 GP GP I GP ;i -- { LB - 33`LB - 33j LB - 33u PLUGMOLD - X-0". LB - 37'x'..:r_.: _..__..� I `=1 9 IG LB -19 N. I CO r cr) M +— ch — —cr) J - -- -- Cr) ( Ca fl m 511 m PROCESSING ROOM CPA LB -19 CD J SPD ci J LC -16©? I LC -18 it • LB -3 i 1 ENLARGED OFFICES — LEFT SCALE = 1/4" =1' -0" RT CHARGING STATION 11 j 1 b lI—LB - 33 LC - 60 fD j\ -iHONE/DATA- - -- r 11 \ PROCESSING ROOM ELEV. A E201 SCALE = 1/4" = 1' -0" 1 EC SHALL CONNECT TO PREWIRED REGISTERS, SODA COOLER AND ICE MACHINES AS SHOWN. CONNECT OWNER SUPPLIED WHIPS TO UNDERFLOOR DUCT SYSTEM AND MAKE ALL FINAL CONNECTIONS. 2 EAS PANEL FOR FUTURE EAS SYSTEM. SEE DETAILS 81E202 AND 9/E202 FOR DETAILS. TYPICAL FOR ALL EAS PANELS. 3 MOUNT JB 18" AFF, BELOW COUNTER, FOR WATER CLOSET FLUSH VALVES. EC SHALL PROVIDE JUNCTION BOXES AT WATER CLOSET AND CONNECT COMPLETE SYSTEM. TRANSFORMERS AND SENSORS BY PC. COVER PLATE SHALL BE PAINTED TO MATCH WALL; 4 MOUNT 18" AFF, BELOW COUNTER, FOR LAVATORY FAUCET SENSORS. PC SHALL PROVIDE TRANSFORMER, SENSOR FAUCETS AND LOW VOLTAGE WIRE CONNECTORS, PC SHALL WIRE LOW VOLTAGE WIRING, U.N.O. 5 ALL RECEPTACLES IN MOTHERS ROOM SHALL BE TAMPER - RESISTANT. SEE SPECIFICATIONS. 6 COORDINATE LOCATION W/ FACTORY INSTALLED LED DISPLAY LIGHTING. 7 EC SHALL CONNECT TO (6) OWNER SUPPLIED POWER SUPPLIES FOR DVR EQUIPMENT. EQUIPMENT ROOM 107 VENDIN (4 I I I I'' i I \ =—_ _ = I ICE LB -4� CREAM MACHIN �•, SODA; COOLER LB - 2 I— ; i i 1 1- I LC - 3 re 1 LB - 6 tarri LC - 1 LB - 10iV LC -15 LB -18 LC - 3 & LB -6 I LC -7& LB -10 LB 121 - y �.` �, PB ,I LC -.111 I LC -13( LC -151 LB -14Q'i LB -16 y1 LB -18` .1,!11 t_ �L.- d' O) e5 1 l Jm© {i( i 7 ENTRY VESTIBULE EXIT VESTIBULE c4; 102 103 1 ENLARGED FRONT END POWER E201 / SCALE = 1/8" = 1' -0" HAND DRYER _AND - =DRYER - =- __ LB 60 • I LB - 56... 11 1 A -38 Fl LB - 11 f- ttz. 1 1 L____L I i I i I I I LL LA -16 `\ 64" C7�'1' LC - 4 LA -16 11 60M -71 , REFRI6E4AATOR...: GFI LA -10 - -�` i EWHa, ( �-<— t i HA - 42 -_I I , ( (; ; IT OFFAAKER. .II 7 !I 11 GFI " -14k h 11 11 �gP li LA 46 ENLARGED BREAK AREA SCALE = 1/8" = 1' -0" 1 1; ;I 1 11 1! 11 II _a_ i J i L ¶ I- ! PLUGMOLD - 3' -0" IC B LC - 8 LB - 35 `, PHON E/DATA —T- Ia^ mrm^ msCm'R9.f�ve4.1./..11.11...11.1../112 CUOMO/ 10 PROCESSING ROOM ELEV. B E201 SCALE = 1/4" =11-0" EC SHALL PROVIDE SINGLE RECEPTACLE WITH ON /OFF - SWITCH FOR COMPRESSOR, MOUNT HIGH JUST INSIDE DOOR FOR EASY ACCESS LA -37 (PHONE LA -35 LJ D-4 -4 511 -O',, (16� BIKE ASSEMBLY ELEVATION SCALE = 1/4" =1' -0" TASK LIGHT r- Lil LB - 42D, ■ m 4Q U U j • 72" JI --l1 i��l I J i I7e1n rJJ Lm MICROWAVE GFI LA -12 46" r n ri 1 iL� I i L L. I PLUGMOLD - 3'-0" -r LB -36 , �! -- IG8 IG9 11 11LC -10 LC -10 9 MANAGERS OFFICE ELEV. A SCALE = 1/4" = /- SEE E102 i1 BOX LA -33[PHONEJD;ATA LC -31 LA -31 E3 I o I. -06^ krtSI T4H- - _74 11 - 1 (ii 1 11 MD ,17b4'-, —J I� 4r- -- _.J__a._— .___.._��..I,+. -" _,rte;.. —__ (2) 4" CONDUITS FOR BURGLAR ALARM SYSTEM. STUB INTO SALE AREA AT DECK, (1 "C) & (2 "C) RUN POWER/DATA DOWN COLUMN AND STUB UP THROUGH FLOOR. I./ l 4) MANAGER'S OFFICE 111 COUNT ROOM 112 PROCESSING ROOM 106 EQUIPMENT ROOM 107 ILB- 394y,4_ -'f 1 - -; LC - 37 5'- 6" ENLARGED ELECTRONICS DESK SCALE = 1/8" = 11 -0" CCTV IG LC -28 T -1 PHONE DVR SYSTEM LC - 30 iDCVR MONITR LC - 32 PLUGMOLD - [G IG 9 I LC -12 LC- 12'!'° 1i E/DATA ____ -: 8 MANAGERS OFFICE ELEV. B E201 SCALE = 1/4" = 1' -0" IP.s. 7 EC SHALL HARDWIRE POWER SUPPLY FROM SAME CIRCUIT. � 15� RETURN GOODS DESK SCALE = 1/4" =1' -0" 14 F.A.C.P. JUNCTION BOX LC -24 FIRE ALARM PANEL UL FIRE ALARM CONTROL PANEL ASSEMBLY WITH AUXILARY POWER SUPPLY EQUIPMENT RM ELE. B E201 / SCALE = 1/4" =11-0" (3) 4" CONDUIT STUBED AT 8'-0 ". RUN ALONG TOP CHORD OF BAR JOIST. STUB 2' INTO SALES FLOOR. PAINT TO MATCH. LC -16 LC -18 IG IG PSB CD') I I (1 "C) & (2 "C) RUN POWER/DATA DOWN COLUMN AND STUB UP THROUGH FLOOR. SPECIAL ORDER DESK (4-2) E201 SCALE = 1/4" = 1' -0" MOTION DETECTOR RELAY RACK SERVER RACK (2) 4" CONDUIT STUBED AT 8' -0 ". TO DECK FOR LV CABLING NOT RUN INTO SALES FLOOR. (2) 4" TELEPHONE SERVICE TO DEMARK. COORDINATE WITH CPM. 13 EQUIPMENT RM ELE. A _E20:1.i SCALE = 1/4" = 1' -0" rl I 11 1 II I ' 7 '11 I I 1 1 1 T i PLUGMOLD - 3' -0" IG LC -14`° ! -PHONE / DATA COUNT ELEV. A SCALE = 1/4" = 1'-0" 12 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 1 9 2010 City of Tukwila BUILDING DIVISION HONE BOARD EC. TO PROVIDE #6 GROUND WIRE FROM PHONE BOARD GROUND TO ELECTRICAL GROUND. BURGLAR ALARM PANEL FIRE ALARM PANEL PLAN RECEIVED EQUIPMENT RM. KEY AR 1 1 2010 PERMIT CENTER E2°:11 SCALE = 1/4" =11-0" CONSTR. DOC & REVISIONS NO. NO 0 DATE 02/26/10 03/08/10 DESCRIPTION ISSUED FOR 90% LL REVIEW ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES DATE DESCRIPTION 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE PAGE ENGINEERS & CONSUL ANTS 923 MAIN STREET, N, WILKESBORO, NC 28 9 PHONE: 336-667-4225 FAX: 336-667-433 ct STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION LOCATION TUMILA7 WA DRAWING TITLE ENLARGED VIEWS AND DETAILS SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. E201 AR CONSTR. DOC & REVISIONS NO DATE DESCRIPTION 02/26/10 ISSUED FOR 90% LL REVIEW EXPOSED DATA/POWER CONDUIT SHALL BE PAINTED TO MATCH PERIMETER WALL 03/08/10 ISSUED FOR BIDS & PERMITS (2) 2" CONDUITS FOR DATA TO DECK. RUN IN WALL TO DECK. 1 1/4" CONDUIT. FOR POWER. MOUNT IN WALL TO DECK POWER: CABLE GRIP #5541 NM WALKER NO.312 -1 1/4 W/ NONMETALIC GRIP �I� 1:1:1:1 ■� -• -•- NO. 2 DUCT BLANK WHIP PROVIDED BY OTHERS FOR BRASS AFTERSET PREWIRED ___ _ �______ - -_ _ ______ ._ _ - _ ____ -. WALKER #H322 -2 TRANSITION (2) 2" CONDUITS TELEPHONE: LOCATION COVER REGISTER BRASS WALKER NO 332UF .. 1/2" CONDUIT. SYSTEM. '1( !. COMMUNICATION °VERTICAL y 90 ELBOW - / POWER: =� #829SRCPLATE TYPICAL NO. 4 WALKER � DUCT BLANK N0.2 WALKER DUCT BLANK BRASS COVER PLATE �, IN SLAB FOR POWER TO #431 BR075 CASH REGISTERS. PROVIDE �1w� ' WALKER NO.H332 90° I I WITH 90° HORIZ. ELBOW AS.� `� REQUIRED. #4220 AFTERSET INSERT (2) #4220 AFTERSET INSERT CORE DRILL 6 1/2" DIAMETER HOLE TO DUCT, THEN DRILL A 2 1/2" HOLE INTO DUCT CENTERED IN A 6 1/2" HOLE IN CONCRETE, GROUT FILL AROUND VERTICAL ELBOW. STUB UP INSIDE WALL AFTERSETS FINISH FLOOR _ DIRECTLY UNDER ACCESS BOX 2" CONCRETE AFTERSET TO FILL VOIDS IN 6 1/2" HOLE, ISOMETRIC ATTACHES TO DUCT WITH LOCKING TABS. .� ®° ° ° o TEAM TO SHALL ATTACH INCLUDED D GONDOLA W/ INCLUDED BRACKET HARDWARE FIXTURED WI GONDOLA TYPE VL' FIXTURE 1/2" ° r-- PANTED TO II ®I I_II NO 2 DUCT 3 1/8" X 1 1/4 WALKER DUCT 4 1 a ° NO. WALKER DUCT G BLANK IN SLAB FOR ° DATA/COMM TO CASH N"--N7111111111111111P MATCH ° �� �� . d ° ° ° ° ° ° a REGISTERS. PROVIDE WITH 90° HORIZ. ELBOW AS SAND NOTE: AFTERSET INSERTS & FITTINGS MUST BE LOCATED BELOW CASH REGISTERS AND CUSTOMER SERVICE DESK. ELECTRICAL CONTRACTOR SHALL NOT CORE DRILL BUILDING SLAB FOR AFTERSET LOCATIONS UNTIL ALL MILLWORK HAS BEEN CONFIRMED. COORDINATE WITH LATEST F1 AND BRU REP. REQUIRED. CONCRETE COMPLETELY SURROUNDING DUCT 3" CONCRETE SUB SLAB EXIT SIGN DETAIL UNDERFLOOR DUCT GROUTING 2 STUB AT WALL p /� �+ PROTOTYPE UPDATES 1 UNDERFLOOR WALKER DUCT DETAIL NO. DESCRIPTION DESCRI4 3 (WALKER 11 ?ATE 58K REV. 0 K E2O,,)SCALE = 3/4" = 1' -0" E202 / E202 / SCALE = 1/16" = 1' -0 ►, J -BOX MOUNTED IN JOIST SPACE SCALE = 3/32" =1' -0" E202 SCALE = 12" = 1' -0" RECESSED BOX 18" X 18" X 6" D. (HOFFMAN) BOX: #/A SG118X18X6 DOOR FRAME: #AFDF1818P, T -R LOCK KIT LOUVER KIT: #A VK86 CENTER 15A, 120V, NEMA, 1/2 INSTALLATION TEAM SHALL ATTACH LIGHT TO TRU GONDOLA SENSOR CONTROL BOX - PAINT TO MATCH - GONDOLA W/ INCLUDED -� / 'Z' BRACKET INSTALLATION / HARDWARE J -BOX MOUNTED INCLUDED W/ _ IN JOIST SPACE r 'Z' (2) 314" C. WITH PULL DOOR () - HP RATED SINGLE STRINGS , TO JOIST POLE SWITCH WITH �. FIXTURE / AREA FOR FUTURE EAS SYSTEM, CONCEAL IN SERVICE b O W PILOT LIGHT, LG. RECEPTACLE FOR i I / TRU GONDOLA('A t BUSH EACH, NSIDE LED BRASS COVER GONDOLA 1 -L - / , / \ - - / VESTIBULE BUMPER GUARD (TYP.) TOP OF PNL, MOUNT 1' -11" A.F.F. 4 "X4" EAS SYSTEM JB WITH TEST EC TO DRILL / SWITCH, SERVICE LED AND HOLE INTO ; \ / � ► CONDUIT AND \ _ � � A 3/4" DIAMETER COLUMN AT BOTH TOP A.F.F. FOR CONTROL CONTROL WIRE DOWN COLUMN TO SENSOR. TYPE 'VL' FIXTURE CONDUIT AND CONDUCTOR TYPICAL I DUPLEX RECEPTACLE BY EC. AND 7' -0" WIRE. ROUTE � CONDUIT TO INSIDE OF 1 FLOOR BOX I I I I � CONDUCTOR TYPICAL jL___,I:I BOX WITH LOCKABLE PANELS BY EC. COLUMN WIREMOLD - JJ - — ACCESS BOOR & LOUVER VENT BY EC. J --"' ate, i �._..,_ COLUMN �� TO EAS PAINT COVER TO MATCH, SENSORS IN SALES AREA ON kiii � CONTROL EAS SYSTEM WIRING PANEL " WALL SURFACE. NOTES: RECEPTACLE IN 1. LOCATE HANDY BOX, BY EC. SIDE OF (NORMAL POWER) SHOWN. COLUMN BOX - TO COLUMN 1 CONDUIT NOTE: UNDERGROUND CONDUIT TO FUTURE EAS I COLUMNS WHERE NOTED AND CONTROL PAINT OF SENSOR TO BE MOUNTED MATCH (TYPICAL) UNO. (SALES AREA 6' -0" SPACING FOR 12' -0" 10' -0" DOORS (TYP.) PEDESTALS: LV WIRING BY 2. BOTTOM 5-2" SPACING FOR 9' -0" & 8' -0" DOORS (TYP.) EAS VENDOR. ELEVATION T -0" A.F.F. 2' -2" FROM INSIDE EDGE OF DOOR FRAME (TYP.) ONLY) VERIFY ALL DIMENSIONS WITH TRU PM BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP 9 EAS PEDESTAL FLOOR DETAIL 8 EAS MOUNTING DETAIL 7 \ SENSOR MOUNTING DETAIL 6 TRU 3 TIER VALANCE TRU 2 TIER VALANCE PROTOTYPEDESIGNATION: SSBS58KPROTOTYPE E202 SCALE = 1/2" = 1' -0" E202 SCALE = 1/16" = 1' -O" C 202 /SCALE = 12" = 1' -0" E202 SCALE = 1/2" = 1' -0" E2 2 SCALE = 1/2" = 1' -0" TOP OF ROOF FRAMING MEMBER [fro.14%,,\..4........ �� A �/ ,�� LNG $Ar TO PROVIDE ANGLES NEEDED PIGTAILS SHALL EXTEND OUT OF FIXTURE FOR FINAL CONNECTION BY EC (TYPICAL CIRCUITING) = v V co ' �' ' x x xC x a /4f PAG E ENGINEERS & GQNSLTLTANTS 923 MAIN STREET. N. WIUCESBORO, NC 28459 PHONE; 336 - 647 -4225 FAX 336.-66 7 4332 I. II •', 3 `"� ? �a�t 'n t 'S q l 3 . 3 -LAMP BALLAST EMERGENCY BALLAST MOUNTED WHERE REQUIRED BY CODE SEISMIC SPLINE LINES AT 45 AT 8, -0" 0.C: (TYPICAL FOR ALL _.--------- FIXTURE T TYPE -�� LTE / CO 'p (WHERE APPLICABLE) FMC TO DECK JUNCTION BOX, PROVIDE APPROX.18" FOR PHASE 'B' SHALL ALWAYS BE CONNECTED MINOR ADJUSTMENTS OF FIXTURE. v BALLAST THAT SHARES EMERGENCY MOUNTING DETAILS) "I TO % BALLAST, AND SHALL BE USED FOR NIGHT A LIGHT CONTROL CIRCUIT. NON - SWITCHED JB MOUNTED TO DECK I ��1�� �1 • ... AIRCRAFT CABLE FURNISHED 4/ CIRCUIT CALLOUTS 2/4/6 / I ` HOUSINGS \ L- -� EC SHALL PROVIDE AND TO JOIST WITH LIGHT FIXTURE ' PHASE 'B' SHALL BE PROVIDED TO ALL ! EMERGENCY PENDANTS, SEE TERMINAL FOR MAIN POWER RUN. �/� STRIP ON ONE -LINE DIAGRAM. UNISTRUT BOLTED ABOVE TOP CHORD (TYP.) INSTALL SCREWS FOR p %� CONNECTION OF ADJOINING CADDY /ERICO SPEED LINK PROVIDE 314" RIGID FIXTURES. CABLE TIE �\ ��� �. BALLAST ABOVE FIXTURE SHC BALL TYPE SWIVEL HANGER, APPLETON PENDANT- COMPACT FLUORESCENT #8456ROREQUAL. FIXTURE TYPE CALLOUT TYPICAL 8' -0" I CONDUIT TO SUPPORT LIGHT FIXTURE. BALLAST ° �� ` 1' /i �'':/ 4.-0" 4' -0 4' -0" , ` HOUSING ACCEPTS 3/4 " THREADING. EC SHALL RUN WIRE THROUGH CONDUIT �- O FIXTURE. ` � `/ �p � � �'� �\ E 4 LAMP FIXTURE - CONNECTION 11I AIRCRAFT CABLE FURNISHED ���� ��� �. LIGHT NON SWITCH SOURCE, OF SAME CIRCUIT AS NORMAL BALLAST SEE TERMINAL SWITCH ON ONE LINE DIAGRAM. EMERGENCY BALLAST WITH FIXTURE I , 8' -0" , , • I �m ��' TYPE "D" FIXTURES U BRACKET LIGHT FIXTURE . FURNISHED NOTE: FIXTURES 1. STRUT SHALL ONLY BE PROVIDED IF AIRCRAFT CABLE EC CANNOT BE SUPPORTED DIRECTLY TO JOIST. WHERE I ,, � N f � 1 / ' 4 (WHERE APPLICABLE) ec LAMP BALLAST E > .t1 0-10V DIING INDICATES CIRCUIT > LINEAR FLUORESCENT NOTE: ALL CONDUIT AND 2. EC SHALL PROVIDE (2) SCREWS FOR EACH CONNECTION OF AN ADJACENT FIXTURE. 3. PRE -SALES AND RECEIVING AREA ARE SIMILAR, EXCEPT LIGHT FIXTURES SHALL BE MOUNTED ABOVE BOTTOM OF JOIST. UNISTRUT SHALL BE PAINTED UN MATCH ROOF DECK. 4. CONTRACTOR SHALL MAINTAIN A UNIFORM 6 " -12" OF TIEBACK ABOVE LIGHT FIXTURE THROUGHOUT SALES FLOOR 12 FIXTURE WIRING DIAGRAMS 11 PENDANT MTG DETAIL (io\ SALES AREA MOUNTING DETAIL REVIEWED FOR COMPLIANCE WITH NFPA7o -NEC MAR 19 2010 o�j E202 SCALE = 12" = 1' -0" �% E202 SCALE = 1" = 1' -0" E202 SCALE = 12" = 1' -0" - , - STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. VERIFY EXACT City of Tukwila BUILDING DIVISION LOCATION FROM 2 -G. BOX LATEST "Fl" PLAN 3/4" C -POWER 46" I' G' LOCATE CONDUITS 5 „ TIGHT TO COLUMN , COLUMN PAINT TO MATCH '" 30" COLUMN. U 'I COLUMN PAINT LOCATION a, / �`� TU KW I LA, WA BOXES MUST BE 22 „ LOCATED BEHIND ACCESS PANEL IN METAL DESK 27" 27 30" 30 49" �\ CONDUITS TO MATCH WALL DRAWING TITLE DETAILS 3/4" C -DATA WORKSTATION. � � \. \ PLAN 1 -G.BOX i-' ELEVATION (13\ METAL DESK WORKSTATION RECEIVED SCALE As indicated ISSUE DATE MARCH 9, 2010 E202 SCALE = 1/8" = 1' -0" SHEET NO MAR 112010 PERMIT CENTER R PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE COMMENTS VOLTS PHASE AMPS M.LO. / M.C.B. A.I.C. I.G. BUS SURF. MNT. REC. MNT. PRE FAB "MDP" 277/480 30, 4W 1000 M.C.B. 50K PNL / 35K CKT BRKS No No No Yes DOUBLE SECTION CKT # DESCRIPTION BKR Am Bo Co BKR DESCRIPTION CKT # 1 ., .. � 225 28.38 4.13 4 225 SODA COOLER 2 (----N 23.97 �\ � 3 HA 28.36 ICE CREAM MACHINE 'T -1" 4 23.97 5 20 0.72 28.38 138 �1 23.97 6 7 "T -2" 100 15.43 0.36 BUSWAY "D" PLGMD. 110 RTU -1 REGISTER /"\ 3.50 23.55 �1 �1 20 9 0.36 15.43 20 10 10 11 11 WATER COOLER 15.43 12 �\ 23.55 20 13 RTU -2 110 23.55 EF -1 20 70 RTU-3 14 1' �� REGISTER 15.79 �1 �1 15 15 7 /Th 23.55 0.36 16 15.79 17 REGISTER 16 23.55 18 l� 15.79 �� 19 RTU-4 70 15.79 19 OFFICE AREA REC., CP -1 25 RTU -8 20 �\ �1 20 5.00 �\ 0.00 21 OFFICE AREA REC. 15.79 PERIM. LINEAR SALES LTG. 22 5.00 23 METAL WORKSTATION 22 15.79 24 �1 5.00 6 25 RTU-9 30 2.77 24 0.00 25 RTU -10 26 �\ 0.72 5.54 20 SPARE 27 0.00 2.77 SPARE 28 5.54 29 0.18 20 2.77 30 �� 5.54 �1 31 RTU -11 30 3.88 20 CUST. SERVICE DESK 35 RTU -A1 32 �1 20 8.03 20 1.31 33 SPARE 3.88 0.00 34 8.03 35 20 1.26 3.88 36 �\ 8.03 n 37 RTU A2 35 8.03 0.36 35 RTU-A3 38 40 �� �\ 37 8.03 20 0.36 39 20 8.03 COUNT RM PLGMD 8.03 41 39 SPECIAL ORDER DESK 8.03 42 �\ 8.03 20 SPARE RTU -A4 35 8.03 SPECIAL ORDER DESK 20 25 RTU-A5 p 54 /1 TRAINING ROOM REC. 5.54 0.00 43 45 20 0.00 1.20 46 5.54 47 44 0.00 8.03 48 /Th 5.54 C--- 49 COMPACTOR 25 1.50 0.00 47 20 BAILER 50 52 �1 0.00 3.00 /1 / 1 51 49 1.50 20 3.00 1.20 /--1 20 1.50 50 3.00 %1 55 SPACE 0 �� 0.00 0.00 20 SPARE 15 POWER METER 56 58 60 0.10 �1 52 57 0.00 0.00 WOMENS HAND DRYER 0.10 59 55 SPARE 0.00 �\ 0.10 �1 MAIN CIRCUIT BREAKER SHALL BE TYPE LSG 205.9 205.9 205.9 TOTAL CONNECTED= 617.7 KVA PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE COMMENTS VOLTS PHASE AMPS M.LO. / M.C.B. ALC. I.G. BUS SURF. MNT. REC. MNT. PRE FAB "LB' 120/208 30, 4W 100 M.LO. 10K FULLY RATED No No Yes No DOUBLE SECTION CKT # DESCRIPTION BKR Ao Bs Co BKR DESCRIPTION CKT # 1 AUTO DOOR OPENER 20 0.72 4.13 4 20 SODA COOLER 2 1.00 3 PHONE BOARD 20 � 0.20 HA 20 ICE CREAM MACHINE 4 120 5 RTU SERVICE REC. 20 0.72 3.83 138 20 EXPRESS REGISTER 6 036 7 DOOR BUZZER 20 0.36 BUSWAY "D" PLGMD. 8 20 REGISTER 8 3.50 9 GP DUPLEX 20 20 0.36 PRESALES/ RECEMNG LTG. 20 REGISTER 10 036 11 WATER COOLER 20 * 15 LINEAR SALES LTG. 0.60 20 REGISTER 12 0.36 13 EF -1 20 0.70 5 * 17 20 REGISTER 14 0.36 15 CU -1 & AHU -1 7 /Th 18 0.36 U :6 5 20 REGISTER 16 17 PRINTER/FAX CUST. SERV. 20 1.00 20 EXPRESS REGISTER 18 17 0.36 19 OFFICE AREA REC., CP -1 20 0.83 3.40 4 20 SPARE 20 0.00 21 OFFICE AREA REC. 20 PERIM. LINEAR SALES LTG. 0:16 0.36 20 METAL WORKSTATION 22 FRONT BREAK/ REST. LTG. 23 VESTIBULE REC. 20 6 *25 0.36 20 SPARE 24 0.00 25 MOTHER'S RM. REC. 20 0.90 0.72 SEE DETAIL 2/E301 20 SPARE 26 0.00 27 SPARE 20 SPARE 0.00 0.18 20 CUST. SERVICE DESK 28 0.18 29 SPARE 20 1.31 0.00 20 CUST. SERVICE DESK 30 0.36 31 SPARE 20 0'00 20 1.31 20 SPARE 32 0.00 33 PROCESSING ROOM 20 20 1.26 33 20 MANAGER OFFICE PLGMD 34 0.18 35 PROCESSING ROOM 20 34 0.36 20 MANAGER OFFICE PLGMD 36 0.18 37 PROCESSING ROOM PLGMD 20 0.36 1.08 20 20 COUNT RM PLGMD 38 0.18 39 SPECIAL ORDER DESK 20 SPARE 1.08 0.00 20 SPARE 40 0.00 41 SPECIAL ORDER DESK 20 20 p 54 20 TRAINING ROOM REC. 42 0.00 43 SPARE 20 0.00 1.20 2.50 20 SPARE 44 0.00 45 SPARE 20 0.00 0.00 30 20 SPARE 46 0.00 47 SPARE 20 47 BIKE LIFT 0.00 20 SPARE 48 0.00 49 SPARE 20 1.20 /--1 20 LAVATORY SENSORS 50 0 51 SPARE 20 1.20 0.00 51 20 SPARE 52 0.00 53 SPARE 20 52 1.20 0.00 20 WOMENS HAND DRYER 54 0.90 55 SPARE 20 0.00 1.20 20 WOMENS HAND DRYER 56 0.90 57 SPARE 20 SPARE 0.00 0.00 20 MENS HAND DRYER 58 0.90 59 SPARE 20 SPARE 58 0.00 20 MENS HAND DRYER 60 0.90 * HANDLE LOCK -ON DEVICE 7.39 7.8 8.08 TOTAL CONNECTED = 2327 KVA PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE VOLTS PHASE AMPS M.L.O./ M.C.B. A.I.C. I.G. BUS SURF. MNT. REC. MNT. PRE FAB COMMENTS "HA" 277/480. 30, 4W 225 M.L.O. 65K PNL / 35K CKT BRKS Yes CKT DESCRIPTION BKR Ao BKR DESCRIPTION 0 I CKT 0 # 3 * 1 LINEAR SALES LTG. COMMENTS 3.26 PHASE AMPS 20 � . 1.G. BUS 2 * 9 20 4.13 3 * 3 LINEAR SALES LTG. 20 10K FULLY RATED `Yes 3.25 No PENDANT SALES LTG. 4 ' 10+ CKT # 4.15 3 * 5 LINEAR SALES LTG. ` 20 BKR DESCRIPTION 3.26 1 6 * 11 0' 4.13 4 * 7 - LINEAR SALES LTG. 2 3.26 3 EXPRESS REGISTER 20 � PENDANT SALES LTG. HA 9 20 3.50 4 * 9 LINEAR SALES LTG. 20 0.72 3.83 0.36 10* 10+ 6 0.36 4 * 11 LINEAR SALES LTG. 20 BUSWAY "D" PLGMD. 8 3.26 12 * 11 3.50 4 * 13 LINEAR SALES LTG. 20 0.36 PRESALES/ RECEMNG LTG. 20 20 VESTIBULE/ COST. LTG. 14* 8 0.56 5 * 15 LINEAR SALES LTG. 20 20 3.81 12 20 SPARE 16 20 0.00 5 * 17 LINEAR SALES LTG. 20 14 0.36 3.81 20 SPARE 18 0.36 0.00 5 * 19 LINEAR SALES LTG. 20 17 PRINTER/FAX CUST. SERV. 20 20 SPARE 20* 20 0.00 6 *21 PERIM. LINEAR SALES LTG. 20 20 3.40 4 20 SPARE 22 20 0.00 6 * 23 PERIM. LINEAR SALES LTG. 20 0.36 HA 3.01 20 FRONT BREAK/ REST. LTG. 24* 23 1.85 6 *25 PERIM. LINEAR SALES LTG. 20 0.62 FIRE ALARM PANEL 24 20 FRONT OFFICE/ REST. LTG. 26* 20 0.72 SEE DETAIL 2/E301 27 SPARE 20 26 0.00 27 20 SPARE 28 0.18 0.00 7 * 29 PRESALES/ RECEIVING LTG. 20 29 SPARE 1.31 20 SPARE 30 DVR SYSTEM 0.00 0.36 7 * 31 PRESALES/ RECEIVING LTG. 20 1.31 20 20 SPARE 32 33 0.00 20 33 SPARE 20 PRICE CHECKERS 0.00 1.08 20 SPARE 34 0.00 0.36 20 35 SPARE 20 37 SPECIAL ORDER DESK 0.00 1.08 20 UH -1 36 SPARE 1 .22 38 0.10 37 SPARE 20 0.00 0.72 20 WATER HEATER 38 41 2.60 20 39 SPARE . 20 * HANDLE LOCK -ON DEVICE 0.00 6.14 20 "FTU" MOTHERS ROOM 40 1.20 2.50 20 41 SPARE 20 1.20 0.00 30 EWH-2 42 6.00 �1 * HANDLE LOCK -ON DEVICE + CONTACTOR #12 FOR NL. 29.65 23.93 31.35 TOTAL CONNECTED = 84.93KVA PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE COMMENTS VOLTS PHASE AMPS M.L.O. / M.C.B. A.I.C. 1.G. BUS SURF. MNT. REC. MNT. PRE FAB "LC" 120/208 30, 4W 100 M.L.O. 10K FULLY RATED `Yes No No Yes No DOUBLE SECTION F CKT # DESCRIPTION BKR Ao Bo Co BKR DESCRIPTION CKT # 1 VIEW MONITOR AND CCTV'S 20 0' 0.36 Yes 20 VIEW MONITOR 2 0.05 3 EXPRESS REGISTER 20 2 0.36 HA 20 TRAINING RM. 4 0.54 5 REGISTER 20 0.72 �� 0.36 20 PROCESSING RM. 6 0.36 7 REGISTER 20 0.36 BUSWAY "D" PLGMD. 8 20 PROCESSING RM. 8 0.36 9 REGISTER 20 12 0.36 PRESALES/ RECEMNG LTG. 20 MANAGER OFFICE 10 0.36 11 REGISTER 20 0- 2 -0-D004 1.25 0.36 20 MANAGER OFFICE 12 0.36 13 REGISTER 20 0'36 2 20A/4P 20 COUNT RM 14 0.36 15 EXPRESS REGISTER 20 2.52 0.36 19 20 RELAY RACK 16 1.00 17 PRINTER/FAX CUST. SERV. 20 20A/4P BUSWAY "H" PLGMD. 0.36 20 SERVER RACK 18 1.00 19 CUST. SERVICE DESK 20 0.18 4 Yes 20 SPARE 20 0.00 21 CUST. SERVICE DESK 20 0.00 0.36 HA 20 BURGLAR ALARM PANEL 22 0.36 23 ELECTRONICS REGISTER 20 Yes 0.00 1'08 20 FIRE ALARM PANEL 24 0.18 25 ELECTRONICS REGISTER 20 0.72 SEE DETAIL 2/E301 0.00 20 METAL WORKSTATION 26 0.18 27 BIKE AREA WRKSTN. 20 11.09 0.18 20 CCTV 28 0.36 29 SPARE 20 0.00 20 DVR SYSTEM 30 0.36 31 IDF, RGD DESK 20 U.18 TOTAL CONNECTED= 6.42 KVA 20 DVR MONITOR _ 32 1.08 33 SPARE 20 0.00 20 PRICE CHECKERS 34 1.08 35 SPECIAL ORDER DESK 20 0.36 20 PRICE CHECKERS 36 1.62 37 SPECIAL ORDER DESK 20 1.08 20 t1 r-\ SPARE SPD 38 0.10 40 39 REGISTRY KIOSK 20 0.72 SPARE 0.10 42 41 EAS SYSTEM 20 0.36 0.10 * HANDLE LOCK -ON DEVICE 5.68 6.14 722 TOTAL CONNECTED= 19.04 KVA THIS IS A DOUBLE SECTION PANELBOARD z O w CO 15 15 16 16 z 0 w c PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE < COMMENTS VOLTS PHASE AMPS M.L.O. / M.C.B. A.I.C. I.G. BUS SURF. MNT. REC. MNT. PRE FAB "LA" 120/208 30, 4W 250 M.C.B. 10K FULLY RATED No No No Yes DOUBLE SECTION F CKT DESCRIPTION BKR Asa Bit Co BKR DESCRIPTION KT c 1 TRU FRONT SIGNAGE 20 0.72 0.36 Yes 20 "C -1" - "C-5" COILS 2 0.05 3 TRU FRONT SIGNAGE 20 2 0.54 HA 20 "C-6" - "C -16" COILS 4 0.11 5 BRU FRONT SIGNAGE 20 0.72 �� 0.90 20 VENDING 6 1.00 7 BRU FRONT SIGNAGE 20 0.72 BUSWAY "D" PLGMD. 8 20 VENDING 8 1.00 9 SPARE • 20 12 0.00 PRESALES/ RECEMNG LTG. 20 REFRIGERATOR 10 1.20 11 SPARE 20 0- 2 -0-D004 1.25 0.00 20 MICROWAVE 12 1.80 13 SPARE 20 0.00 2 20A/4P 20 COFFEE MAKER 14 120 15 SPARE 20 2.52 0.00 19 20 BREAK RM. REC. 16 0.72 17 DOCK REC. & LTG. 20 20A/4P BUSWAY "H" PLGMD. 0.36 20 SPARE . 18 0.00 19 DOCK REC. & LTG. 20 0.36 4 Yes 20 SPARE 20 0.00 21 RTU SERVICE REC. 20 0.00 1.26 HA 20 SPARE 22 0.00 23 BRU SALES REC. 20 Yes 0.00 0.72 20 SPARE 24 0.00 25 TRU SALES REC. 20 0.72 SEE DETAIL 2/E301 0.00 20 SPARE 26 0.00 27 SPARE 20 11.09 0.00 20 ELECTRONICS REGISTER 28 1.08 29 RGD PLUGMOLD 20 0.18 20 ELECTRONICS REGISTER 30 0.72 31 RGD DESK REC. 20 0.18 TOTAL CONNECTED= 6.42 KVA 20 ELECTRONICS REGISTER 32 1.08 33 RGD DESK REC. 20 0.18 20 BIKE WORKSTATION 34 0.18 35 BIKE ASSEMBLY PLGMD, EF3 20 0.36 20 SPARE 36 0.00 37 BIKE ASSEMBLY 20 0.18 20 SPARE 38 0.00 39 SPARE 20 0.00 20 SPARE 40 0.00 41 SPARE 20 0.00 20 SPARE 42 0.00 43 BIKE LIFT 20 1.20 20 BIKE LIFT 44 1.20 45 120 46 �1 1.20 47 BIKE LIFT 20 1.20 20 BIKE LIFT 48 1.20 /--1 49 120 50 1.20 �1 51 SPARE 20 0.00 20 BIKE LIFT 52 1.20 /Th 53 SPARE 20 0.00 54 1.20 55 SPARE 20 0.00 20 SPARE 56 0.00 57 SPARE 20 0.00 20 SPARE 58 0.00 59 SPARE 20 0.00 20 SPARE 60 0.00 * HANDLE LOCK -ON DEVICE 11.01 8.87 9.64 TOTAL CONNECTED= 29.52 KVA PLAT ID. CRITICAL PANEL INFORMATION MOUNT TYPE COMMENTS VOLTS PHASE AMPS M.LO. / M.C.B. A.I.C. I.G. BUS SURF. MNT. REC. MNT. PRE FAB " 120/208 30, 4W 100 M.C.B. 10K FULLY RATED No No No Yes 150° _"1.131" CKT # DESCRIPTION BKR Ao Bo Co BKR DESCRIPTION CKT # 1 BUSWAY "A" PLGMD. 60 /--\ LA 0.36 Yes HA 60 0- 2- 0- D007 BUSWAY "B" PLGMD. 2 1.98 4 2 0.36 HA 3 0.72 6 "C-5" 20A/4P 0.36 5 0.72 �� 7 BUSWAY "C" PLGMD. 60 �1 �\ �� "C-6" 0.34 LA 4 60 /\ HA BUSWAY "D" PLGMD. 8 1.98 10 20A/4P 0.67 4 9 0.36 12 0- 2 -0-D005 PRESALES/ RECEMNG LTG. 0.67 11 0.72 �1 13 BUSWAY "E" PLGMD. 60 �� �1 �1 0- 2 -0-D004 1.25 "C-9" 20A/4P 60 �� 4 BUSWAY "F" PLGMD. 14 2.88 16 PENDANT (3) LAMPS 2 20A/4P 15 88 18 HA SEE DETAIL 21E301 2.50 17 2.52 (1 19 BUSWAY "G" PLGMD. 60 �1 �\ 11 HA 2.33 0-2-1-D006 PENDANT (3) LAMPS 60 �1 20A/4P BUSWAY "H" PLGMD. 20 2.16 22 SEE DETAIL 2/E301 2.16 PENDANT NL LAMPS 21 2.16 24 4 Yes 2.16 23 1.44 f---- 25 SPARE 20 0.00 Yes HA 20 SPARE 26 0.00 27 SPARE 20 Yes 0.00 SEE DETAIL 2IE301 20 SPARE 28 0.00 29 SPARE 20 LA SEE DETAIL 2/E301 0.00 20 SPARE 30 0.00 * HANDLE LOCK -ON DEVICE 13.27 10.75 11.09 TOTAL CONNECTED= 35.11 KVA NOTE: EC SHALL PROVIDE NEW TYPEWRITTEN DIRECTORIES IN PANELBOARDS WHERE CIRCUITS HAVE BEEN REVISED OR ADDED, INDICATING LOAD CHANGES OR ADDITIONS. TRANSFORMER SCHEDULE: PLAN MARK KVA PHASE PRI. VOLT. SEC. VOLT. TEMP RISE COMMENTS SERVING PNL "T -1" 150 30 480 120/208 150° MOUNTED ABOVE POWER WALL BY EC LA & LD "T -2" 75 30 480 120/208 150° MOUNTED AT DECK ABOVE PANEL 'LB' AND 'LC' BY EC LB & LC PLAN I.D. CONTACTOR SCHEDULE. . MOUNT TYPE DESCRIPTION COIL CONTROL COMMENTS MARK AMP / POLES PNL CKT ELEC. HELD PNL CM'S OUTPUT # 30, 4W "C -1" 100A/3P LA 2 No LD1 PANEL 0- 2 -0-D008 VALANCE $. TRACK LTG. "C-2" 100A/3P LA 2 No LD2 PANEL 0- 2 -0-D008 VALANCE & TRACK LTG. "C-3" 20A/4P LA 2 Yes HA SEE DETAIL 2/E301 0- 2- 0- D007 LINEAR SALES LTG. "C-4" 20A/4P LA 2 Yes HA SEE DETAIL 2/E301 0- 2 -0-D007 LINEAR SALES LTG. "C-5" 20A/4P LA 2 Yes HA SEE DETAIL 2/E301 0- 2 -0-DO07 LINEAR SALES LTG. "C-6" 20A/4P LA 4 Yes HA SEE DETAIL 2/E301 0- 2 -0-0006 LINEAR SALES LTG. (PERIMETER LTG) "c -r 20A/4P LA 4 Yes HA SEE DETAIL 2/E301 0- 2 -0-D005 PRESALES/ RECEMNG LTG. "C-8" 20A14P LA 4 Yes HA SEE DETAIL 2/E301 0- 2 -0-D004 VESTIBULE/ CUST. LTG. "C-9" 20A/4P LA 4 Yes HA SEE DETAIL 2/E301 0-2-1-D008 PENDANT (3) LAMPS "C -10" 20A/4P LA 4 Yes HA SEE DETAIL 21E301 0 -2 -1 -0007 PENDANT (3) LAMPS "C -11" 20A/4P LA 4 Yes HA SEE DETAIL 2IE301 0-2-1-D006 PENDANT (3) LAMPS "C -12" 20A/4P LA 4 Yes HA SEE DETAIL 2/E301 0-2-1-D005 PENDANT NL LAMPS "C -13" 20A/4P LA 4 Yes HA SEE DETAIL 21E301 0.2- 1-D004 SECURITY LIGHTING "C -14" 20A/4P LA 4 Yes HA SEE DETAIL 21E301 0 -2 -1 -0003 EXTERIOR LIGHTING "C -15" 20A/4P LA 4 Yes LA SEE DETAIL 2IE301 0 -2 -1 -0002 TRU EXTERIOR SIGNAGE "C -16" 20A/4P LA 4 Yes LA SEE DETAIL 2/E301 0.2.1 -D002 BRU EXTERIOR SIGNAGE PLAN I.D. CRITICAL PANEL INFORMATION MOUNT TYPE COMMENTS VOLTS PHASE AMPS M.LO. / M.C.B. A.I.C. I.G. BUS SURF. MNT. REC. MNT. PRE FAB "LD2' 120/208 30, 4W 100 M.C.B. 10K FULLY RATED No No No Yes CKT # DESCRIPTION BKR Ao Bo Co BKR _ DESCRIPTION CKT # 1 VALANCE LIGHTS 20 0.87 20 PLGMD. 2 1.08 3 PLGMD. 20 0.36 20 PLGMD. 4 1.08 5 SPARE 20 0.00 20 BIKE VALANCE LIGHTS 6 1.43 7 ELECTR. PLGMD. 20 0.54 20 SPARE 8 0.00 9 ELECTR. PLGMD. 20 0.89 20 SPARE 10 0.00 11 SPARE 20 0.00 20 ELECTR. DESK RECEPT. 12 0.18 13 SPARE 20 0.00 20 SPARE 14 0.00 15 SPARE 20 0.00 20 SPARE 16 0.00 17 SPARE Z0 0.00 20 SPARE 18 0.00 19 SPARE 20 0.00 20 SPARE 20 0.00 21 SPARE 20 0.00 20 SPARE 22 0.00 23 SPARE 20 0.00 20 SPARE 24 0.00 25 SPARE 20 0.00 20 SPARE 26 0.00 27 SPARE 20 0.00 20 SPARE 28 0.00 29 SPARE 20 0.00 20 SPARE 30 0.00 * HANDLE LOCK -ON DEVICE 2.49. 2.33 1.61 TOTAL CONNECTED= 6.42 KVA CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION NO. 03/08/10 ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE PAGE ENGINEERS & CONSULT TS 923 MAIN STREET, N. WILKESBORO, NC 2865 PHONE: 336 =667 -4225 FAX: 336- 6674332 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 192010 City of Tukwila BUILDING DIVISION RECEIVED MAR 112010 PERMIT CENTER STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA DRAWING TITLE PANEL SCHEDULES SCALE ISSUE DATE MARCH 9, 2010 NOTE: PROVIDE THE FOLLOWING QUANTITIES: 1 POLE CIRCUIT - 1 HOT, 1 NEUTRAL, 1 GROUND 2 POLE CIRCUIT - 2 HOT, 1 GROUND 3 POLE CIRCUIT - 3 HOT, 1 GROUND 1 POLE IG CIRCUIT -1 HOT. 1 NEUTRAL, 1 GROUND, 1 ISOLATED GROUND. MINIMUM WIRE & CONDUIT SIZES FOR CIRCUIT BREAKERS AND FUSES AMPS LOAD ANALYSIS AT PANELBOARDS: GROUND (CU) HA MISC. MECHANICAL LIGHTING TOTAL 8.60 KVA X 1.00 = 8.60 3.72 KVA X 1.00 = 3.72 72.61 KVA X 1.00 = 72.61 84.93 KVA 84.93 84.93 KVA = 102.5 KVA KVA KVA KVA AMPS LC RECEPTACLES MISC. TOTAL FIRST 10 KVA 10.0 KVA X 1.00 =10.00 KVA 18.74 REMAINING 8.74 KVA X 0.50 = 427 KVA 020 KVA X 1.00 = 0.30 KVA 19.04 KVA 14.67 KVA 14.67 KVA = 40.72 AMPS LA RECEPTACLES MISC. MECHANICAL TOTAL FIRST 10 KVA 10.0 KVA X 1.00 = 10.0 13.16 REMAINING 3.16 KVA X 0.50 = 1.58 4.36 KVA X 1.00 = 4.36 12.00 KVA X 1.00 = 12.00 29.52 KVA 27.94 27.94 KVA = 77.55 KVA KVA KVA KVA KVA AMPS LD1 RECEPTACLES LIGHTING TOTAL FIRST 10 KVA 10.0 KVA X 1.00 =10.00 KVA 32.76 REMAINING 22.76 KVA X 0.50 =11.38 KVA 2.35 KVA X 1.00 = 2.35 KVA 35.11 KVA 23.70 KVA 23.70 KVA = 65.87 AMPS LB RECEPTACLES MISC. MECHANICAL TOTAL FIRST 10 KVA 10.0 KVA X1.00 =10.00 13.16 REMAINING 3.16 KVA X 0.50 = 1.58 7.41 KVA X 1.00 = 7.41 2.70 KVA X 1.00 = 2.70 23.27 KVA 21.69 21.69 KVA = 60.21 KVA KVA KVA KVA KVA AMPS LD2 RECEPTACLES LIGHTING TOTAL FIRST 10 KVA 3.96 KVA X 1.00 = 3.96 KVA 3.96 REMAINING 0 KVA X 0.50 = 0 KVA 2.46 KVA X 1.00 = 2.46 KVA 6.42 KvA 6.42 KVA 6.42 KVA =17.82 AMPS NOTE: PROVIDE THE FOLLOWING QUANTITIES: 1 POLE CIRCUIT - 1 HOT, 1 NEUTRAL, 1 GROUND 2 POLE CIRCUIT - 2 HOT, 1 GROUND 3 POLE CIRCUIT - 3 HOT, 1 GROUND 1 POLE IG CIRCUIT -1 HOT. 1 NEUTRAL, 1 GROUND, 1 ISOLATED GROUND. MINIMUM WIRE & CONDUIT SIZES FOR CIRCUIT BREAKERS AND FUSES AMPS FEEDER SIZE (CU) GROUND (CU) CONDUIT 15 #12 #12 3/4" 20 #12 #12 3/4" 25 #10 #10 3/4" 30 #10 #10 3/4" 35 #8 #10 3/4" 40 #8 #10 3/4" 45 #8 #10 3/4" 50 #8 #10 3/4" 60 #6 #10 3/4" 70 #4 #8 1" 80 #4 #8 1" 90 #3 #8 1 -1/4" 100 #3 #8 1 -1/4" T1 150KVA XFMR 480V 30 DRY TYPE TRANSFORMER - SEE ONE LINE DIAGRAM FOR CONDUCTOR SIZES NEUTRAL_ DEMAND LOAD ANALYSIS LIGHTING 77.42 KVA X 1.00 = RECEPTACLES 81.78 KVA FIRST 10KW 10.0 KVA X 1.00 = REMAINING 71.78 KVA X .5 = MECHANICAL 444.10 KVA X 1.00 = MISC. 20.67 KVA X 1.00 = 77.42 KVA 10.00 KVA 35.89 KVA 444.10 KVA 20.67 KVA SUB -TOTAL 585.08 KVA = 703.74 AMPS + 25% OF LARGEST MOTOR 9.0 X .25 = 2.0 KVA TOTAL 587.08 KVA = 706.15 AMPS 120/208V - 3o 4W NOTE: 3 PHASE, 1 PHASE SIMILAR - NEAREST AVAILABLE GROUNDED STRUCTURAL METAL MEMBER SEPARATE NC SYSTEM SCALE = 6" = 1' -0" C/T CABINET MIN. 4 -250 MCM COPPER FROM SERVICE ENTRANCE INCOMING SERVICE NOTE: WHERE CONDUIT IS USED TO PROTECT THE GROUNDING CONDUCTOR, IT SHALL BE BONDED TO THE CONDUCTOR CONNECT TO BUILDING STEEL METAL WATER AT BOTH ENDS MAIN(PROVIDE JUMPERS AS REQUIRED), AND STEEL RE -BARS (MIN. 201) IN FOOTING 1200A MAIN LUGS LINETYPE LEGEND PROVIDED BY CONTRACTOR PROVIDED BY OWNER VIA PREFAB MANUFACTURER 4 SETS OF (4) 250 KCMIL, #2/0 CU. GND, 3" CONDUIT. EC SHALL RUN MAIN FEEDS THROUGH PREWIRED CIT'S. #3/0 COPPER NEUTRAL #3/0 COPPER SERVICE GROUND DETAIL SCALE = 6" = 1' -0" NOTE: POWER WALL LAYOUT FOR INFORMATION PURPOSES ONLY CONTACT HILL - PHOENIX FOR JOB SPECIFIC LAYOUT BEFORE STUB -UPS ARE INSTALLED. TOP VIEW T1 150KVA XFMR 0 r 5/8" DIA. HOLES FOR ANCHOR BOLTS SUPPLIED BY CUST. (NOTE: TRANSFORMER MUST BE ANCHORED TO A MASONRY WALL. IF IT ISN 'T, USE ALTERNATIVE ANCHORING METHOD.) REMOVABLE LIFTING BRACKETS/TUBES FIELD MOUNT TRANSFORMER TO TRANS. MNTG. BASE W/4 EA. 3/8" -16X1" HEX HD GR5 BOLTS (NUTS PRE - WELDED TO BASE) MDP 1000A MCB TYPE LSG 90X45X1B EMS CABINET 5/8" DIA. HOLES FOR ANCHOR BOLTS SUPPLIED BY CUST. TYP. LEFT VIEW 3' -4" 3' -4" 3' - 4' 3' -9" 13' -9" 5 POWER WALL ELEVATION E302 SCALE = 3/4" = 1' -0" FRONT VIEW T1 150KVA XFMR 1' -6" RIGHT SIDE UTILITY COMPANY TRANSFORMER I METER I AND CTS __J RTU RTU #1 #2 RTU RTU RTU RTU #3 #4 #A1 #A2 /g7 /c> ( ( ( RTU RTU RTU RTU RTU RTU RTU COMPACTOR #A5 #A3 #8 #9 #10 #11 #A4 BAILER ( ( ( ( ( (, ( .o .o .o •o •o UU .N N U ip Ci U U 0,- _ UM V i=i▪ - GM CM _� 1000.0, 480/277V, 3PH, 4W, SWBD ----------------- �- 7 7 b b - 7b --- - - - - M D P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 110( 110( 70( 7Q( 35( 35( 251 35( 25 ( 30( 25( 30( 35( 25( 20( 1000.0- 3P,GFI `Q `? 2 `Q `Q `? �Q 3 NQ .Q N? .Q .q N? .Q N? .Q 19 20 - --� � - -b- 4-- --- b - - - -- 4 5 � I 6 7 12 13 r 1136 14 8 9 10 11 15 17 18 3P �� 3P ( 3P ( W 15A( D U 0 U d U 0 0 0 _ o co I. co °z/11�� (°z� MV IVV VV Ft U d CM z .\z Z Co co C9 - (9 ii p0 U :: Dd o0M o� _oM #'z -z -z e..0 z..'..)0 N (/ 225A - T--- - - 4- -- - 4- G Q 225A' Q 100.0" L- I _I- I - I_ 1 --- - - - - -- --------------------------- ---------------------------- - - - - -- I I I I 1 3/O CU 0 - - - - N UFER/ FOOTING REBAR BLDG. STEEL WATER PIPE GROUND ROD TELEPHONE BOARD (4) 350 AL, #2 AL GND PANEL "HA' 250A M.L.O. 277/480V 3PH,4W ..0 -3.. "C-4" "C -5" "C -6" ..0 -7" 1- -(I I-1- - -I- I I 1- - -1� I I- -Id I i- - -1H H L_J L_J L_J L_J L_J CKT# CKT# CKT# CKT# CKT# I 1 IX I aaa 2 2 2 2 "C-9" --� �H 1 1 I 111 "C -1I0" - - -1 I-1- L -J L_J CKT# CKT# N CO i 2= "C -13" "C -14" I- f L_J L_J CKT# CKT# r L L N N N � I aaa _ 2 "C -1I1" - -�If L -J CKT# CO I- I I 2 = TERMINAL STRIP 1 � CO ,. 4) ti CD r co tr) 1� N N N N t) I . . 1 1 1 1 1 1. 1 1 1 1 1 __________________j 1 TO EMERGENCY BALLASTS AND LINEAR NIGHT LIGHT CIRCUITS N c') "C -12" -I 1-1 L_ _J CKT# o FINAL PRIMARY AND - SECONDARY FEEDER TERMINATIONS AT TRANSFORMER LUGS BY CONTRACTOR. r I 150 KVA L _ #1 /OCU.TO NEAREST STEEL d / 1 / d / z / 0 / � I 0<1 (4)#1/0 AL, #6 AL GND, 2 "C L4) #110 AL, #6 AL GND, 2 "C PANEL "LA -1" DOUBLE SECTION PANEL (SECTION 1) 400A BUSS 250A M.C.B. 120/208V 3PH,4W W/ FEED THROUGH LUGS. L_F GENERAL NOTE: PANEL "LA -2" DOUBLE SECTION PANEL (SECTION 2) 400A M.L.O. 120/208V 3PH,4W L "C-1 5" "C -16" L �FH - -HH L_J L -J CKT# CKT# � M 1 1 r 1P( 00 "C -1" PANEL "LD -1" 100A M.C.B. 100A BUS 120/208V 3PH,4W #6 CU GND, #4 CU IG, 2 "C U T /b 100 (, Q PANEL "LD-2" 100A M.C.B. 100A BUS 120/208V 3PH,4W 1. POWER WALL PROVIDER SHALL MAKE CONNECTIONS FROM PANEL TO CONTACTORS AND TERMINAL STRIP, CIRCUITS AS SHOWN. EC SHALL PROVIDE FINAL CONNECTIONS ON OTHERSIDE OF CONTACTOR. 2. CONNECTIONS TO TERMINAL STRIP SHALL BE UNSWITCHED FOR CONNECTION TO EMERGENCY BALLASTS. 3. CONTACTORS ARE CONTROLLED BY EMS THROUGH PILOT RELAYS PROVIDED AND INSTALLED BY POWER WALL MANUFACTURER. 4. PENDANT NIGHT LIGHTS SHALL BE CONTROLLED FROM CONTACTOR C-12. 5. ALL RTU'S SHALL HAVE INTERNAL, FACTORY MOUNTED CIRCUIT BREAKERS. 21 ONE -LINE DIAGRAM E302 SCALE = 12" = 1' -0" LOCKABLE DISCONNECT MOUNTED AT TRANSFORMER 1/2A 3PH, PANEL MTD., IN -LINE FUSES J 100A r 1 ,75 2KVA .g-2 100A 100AF E 0 z 0 0 N (j O - 1U et CU. TO N REST STEEL � L 100A100.0 F -� r PANEL "LC" 100A M.L.O. 120/208V 3PH, 4W PANEL "LB -1" T DOUBLE SECTION PANEL (SECTION 1) 100A M.L.O. 120/208V 3PH, 4W W/ FEED THROUGH LUGS. PANEL "LB -2" DOUBLE SECTION PANEL (SECTION 2) 100A M.L.O. 120/208V 3PH, 4W - -----J L 1 -I- T POWER 1 LMETER1 J REVIEWED FOR COMPLIANCE EWIITH NFPA 70 MAR 19 2010 City of Tu BUILDING DIVISION RECEIVED MAR 112010 PERMIT CENTER CONSTR. __DOC & REVISIONS DATE 03/08/10 DESCRIPTION ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE 10/28/09 DESCRIPTION 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE PAGE ENGINEERS & CONSULT TS 923 MAIN STREET. N. WILKESBORO. NC 28659 PHONE; 336 -667 -4225 FAX: 336 -667 -4332 STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA DRAWING TITLE ONE -LINE DIAGRAM SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. E302 %w " ° o -- a - 4,-_ o LA-2 HA VVVT O MDP EMS LD -1 I \\- LD -2 - - - I - q= -..,J T1 150KVA XFMR L NOTE: POWER WALL LAYOUT FOR INFORMATION PURPOSES ONLY CONTACT HILL - PHOENIX FOR JOB SPECIFIC LAYOUT BEFORE STUB -UPS ARE INSTALLED. TOP VIEW T1 150KVA XFMR 0 r 5/8" DIA. HOLES FOR ANCHOR BOLTS SUPPLIED BY CUST. (NOTE: TRANSFORMER MUST BE ANCHORED TO A MASONRY WALL. IF IT ISN 'T, USE ALTERNATIVE ANCHORING METHOD.) REMOVABLE LIFTING BRACKETS/TUBES FIELD MOUNT TRANSFORMER TO TRANS. MNTG. BASE W/4 EA. 3/8" -16X1" HEX HD GR5 BOLTS (NUTS PRE - WELDED TO BASE) MDP 1000A MCB TYPE LSG 90X45X1B EMS CABINET 5/8" DIA. HOLES FOR ANCHOR BOLTS SUPPLIED BY CUST. TYP. LEFT VIEW 3' -4" 3' -4" 3' - 4' 3' -9" 13' -9" 5 POWER WALL ELEVATION E302 SCALE = 3/4" = 1' -0" FRONT VIEW T1 150KVA XFMR 1' -6" RIGHT SIDE UTILITY COMPANY TRANSFORMER I METER I AND CTS __J RTU RTU #1 #2 RTU RTU RTU RTU #3 #4 #A1 #A2 /g7 /c> ( ( ( RTU RTU RTU RTU RTU RTU RTU COMPACTOR #A5 #A3 #8 #9 #10 #11 #A4 BAILER ( ( ( ( ( (, ( .o .o .o •o •o UU .N N U ip Ci U U 0,- _ UM V i=i▪ - GM CM _� 1000.0, 480/277V, 3PH, 4W, SWBD ----------------- �- 7 7 b b - 7b --- - - - - M D P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 3P 110( 110( 70( 7Q( 35( 35( 251 35( 25 ( 30( 25( 30( 35( 25( 20( 1000.0- 3P,GFI `Q `? 2 `Q `Q `? �Q 3 NQ .Q N? .Q .q N? .Q N? .Q 19 20 - --� � - -b- 4-- --- b - - - -- 4 5 � I 6 7 12 13 r 1136 14 8 9 10 11 15 17 18 3P �� 3P ( 3P ( W 15A( D U 0 U d U 0 0 0 _ o co I. co °z/11�� (°z� MV IVV VV Ft U d CM z .\z Z Co co C9 - (9 ii p0 U :: Dd o0M o� _oM #'z -z -z e..0 z..'..)0 N (/ 225A - T--- - - 4- -- - 4- G Q 225A' Q 100.0" L- I _I- I - I_ 1 --- - - - - -- --------------------------- ---------------------------- - - - - -- I I I I 1 3/O CU 0 - - - - N UFER/ FOOTING REBAR BLDG. STEEL WATER PIPE GROUND ROD TELEPHONE BOARD (4) 350 AL, #2 AL GND PANEL "HA' 250A M.L.O. 277/480V 3PH,4W ..0 -3.. "C-4" "C -5" "C -6" ..0 -7" 1- -(I I-1- - -I- I I 1- - -1� I I- -Id I i- - -1H H L_J L_J L_J L_J L_J CKT# CKT# CKT# CKT# CKT# I 1 IX I aaa 2 2 2 2 "C-9" --� �H 1 1 I 111 "C -1I0" - - -1 I-1- L -J L_J CKT# CKT# N CO i 2= "C -13" "C -14" I- f L_J L_J CKT# CKT# r L L N N N � I aaa _ 2 "C -1I1" - -�If L -J CKT# CO I- I I 2 = TERMINAL STRIP 1 � CO ,. 4) ti CD r co tr) 1� N N N N t) I . . 1 1 1 1 1 1. 1 1 1 1 1 __________________j 1 TO EMERGENCY BALLASTS AND LINEAR NIGHT LIGHT CIRCUITS N c') "C -12" -I 1-1 L_ _J CKT# o FINAL PRIMARY AND - SECONDARY FEEDER TERMINATIONS AT TRANSFORMER LUGS BY CONTRACTOR. r I 150 KVA L _ #1 /OCU.TO NEAREST STEEL d / 1 / d / z / 0 / � I 0<1 (4)#1/0 AL, #6 AL GND, 2 "C L4) #110 AL, #6 AL GND, 2 "C PANEL "LA -1" DOUBLE SECTION PANEL (SECTION 1) 400A BUSS 250A M.C.B. 120/208V 3PH,4W W/ FEED THROUGH LUGS. L_F GENERAL NOTE: PANEL "LA -2" DOUBLE SECTION PANEL (SECTION 2) 400A M.L.O. 120/208V 3PH,4W L "C-1 5" "C -16" L �FH - -HH L_J L -J CKT# CKT# � M 1 1 r 1P( 00 "C -1" PANEL "LD -1" 100A M.C.B. 100A BUS 120/208V 3PH,4W #6 CU GND, #4 CU IG, 2 "C U T /b 100 (, Q PANEL "LD-2" 100A M.C.B. 100A BUS 120/208V 3PH,4W 1. POWER WALL PROVIDER SHALL MAKE CONNECTIONS FROM PANEL TO CONTACTORS AND TERMINAL STRIP, CIRCUITS AS SHOWN. EC SHALL PROVIDE FINAL CONNECTIONS ON OTHERSIDE OF CONTACTOR. 2. CONNECTIONS TO TERMINAL STRIP SHALL BE UNSWITCHED FOR CONNECTION TO EMERGENCY BALLASTS. 3. CONTACTORS ARE CONTROLLED BY EMS THROUGH PILOT RELAYS PROVIDED AND INSTALLED BY POWER WALL MANUFACTURER. 4. PENDANT NIGHT LIGHTS SHALL BE CONTROLLED FROM CONTACTOR C-12. 5. ALL RTU'S SHALL HAVE INTERNAL, FACTORY MOUNTED CIRCUIT BREAKERS. 21 ONE -LINE DIAGRAM E302 SCALE = 12" = 1' -0" LOCKABLE DISCONNECT MOUNTED AT TRANSFORMER 1/2A 3PH, PANEL MTD., IN -LINE FUSES J 100A r 1 ,75 2KVA .g-2 100A 100AF E 0 z 0 0 N (j O - 1U et CU. TO N REST STEEL � L 100A100.0 F -� r PANEL "LC" 100A M.L.O. 120/208V 3PH, 4W PANEL "LB -1" T DOUBLE SECTION PANEL (SECTION 1) 100A M.L.O. 120/208V 3PH, 4W W/ FEED THROUGH LUGS. PANEL "LB -2" DOUBLE SECTION PANEL (SECTION 2) 100A M.L.O. 120/208V 3PH, 4W - -----J L 1 -I- T POWER 1 LMETER1 J REVIEWED FOR COMPLIANCE EWIITH NFPA 70 MAR 19 2010 City of Tu BUILDING DIVISION RECEIVED MAR 112010 PERMIT CENTER CONSTR. __DOC & REVISIONS DATE 03/08/10 DESCRIPTION ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO. DATE 10/28/09 DESCRIPTION 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE PAGE ENGINEERS & CONSULT TS 923 MAIN STREET. N. WILKESBORO. NC 28659 PHONE; 336 -667 -4225 FAX: 336 -667 -4332 STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA DRAWING TITLE ONE -LINE DIAGRAM SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. E302 %w 0 RTU CONTROL WIRING 0 EXHAUST FAN CONTROL LIGHTING OVERRIDE CONTROL ® © 24VDC PILOT RELAYS (TYP FOR 20) ® (NOT F USED o (4) SWITCH ASSEMBLY (EF -1) OATH -1 HOFFMAN STAINLESS STEEL OATH -1 (INTERCONNECTS, TEMPERATURE AND CO2 SENSORS) CONTINUOUS HINGE, TYPE 4X CO2 SENSOR- 0- 2000PPM 4-20MA NOTE MOUNT AT REAR A1212CHNFSS- Al2P12- CPMK12, BY EC. 3m.,.. .,4..vre = Serra eery ' OF STORE, ABOVE EMS AND POWER WALL, FIELD COORDINATE WITH ROOFING INSTALLER AND ALL OTHER DISCIPLINES. -�� ® B RH+ RH- ROOM HUMIDITY SENSOR 2% 4 -20MA OR O-5VDC BAPI BAIH200 -R Paver Nall N,� o, RIM f 16- 20.z9-36} --3 1 1 ROOM TEMPERATURE 4 -20MA (EQUIPMENT RM) J 4!14'70 1O 317 Lltltum O CR42 6 at Be .9,0 1_ +I „Left Feed BrerCod r BAC met' av D..,m. '® " 7. -\_ 3.o.mma , ,.cmran wn&Br .R40 .� .� . =Ewes, Ed...l,m.rt ® ®- Module Address BY HILL - PHOENIX, EC SHALL CONNECT CIRCUITS AS REQUIRED TO CONTACTS. 1 21) Light Override 1 J 7 liii sii �,D,,,. endd M2V ,Da Xne, Remote Expansion ALS-1 CONTROL BOARD BY 1 OWNER) MOUNTED TO SNAP 12 ) !® ®I ®I RTU BACNET INTERFACE BOARD (FACTORY INSTALLED) SYS BUS LE12100 p CT-B 122 > Light Override 2 �a .:e"� ME812u r ®,.�;IE I LDIM2 ®Il® La II:ICI TRACK, BY EC. aeNa 123 > Light Override 3 ■4 o N.a 84'18 0 7. I ®I ED c I �- W Q tl f.) P `� & T+ T- • N4 ::® O j i l t mV Fusin STARTER 0❑ PROVIDED AND U W - tO 0 Li- o w i m O I 2 ) Light Override 4 m emnmoa U0-8 , Or 14 1/2" NPT FOR ALS-1. U06 , U0.4, INSTALLED By EC - UO2, 24V00 29Vd4 + G _ option DR., m O Y.blal 2110c omn I 1 © 0 1019 (BASED ON LENNOX) RTU MTD. TERMINAL STRIP ALS -1 ® SPACE TEMPERATURE SENSOR O SPACE HUMIDITY SENSOR TRANSDUCER CONTROL BOARD TO NEXT RTU ® FOR DIMMING BALLASTS (TYPICAL FOR 3) a 00000000000000000000000 1 2 3 4 5 6 7 8 91011121314151817181920212223 0000 00 00000 0000 0 0000000 < ($T-1) (RHS-1) +2 O & pee: ems__ YAK' __ __._ MID MEW IS> LIGHT LEVEL sETPOINT - _ FROM EMS remmM.p Le ° �-'r4 §"�� �_ 5 - 0101010 ∎• f- - IR ■ _ ri.❑` (In0101010 2 1 8 7 8 5 4 3 2 1 al .D :',. MABLE 0 CO2 Sensor T -STAY TYP FOR RTU-3 & 5 TYP FOR ALL D �� 4 OUTDOOR SENSOR ASSEMBLY _ EMS1 SCALE = 1/2" = I' -0" 1EXT TO T4 EMS1 SCALE = 1/2" = 1' -0" 2 DETAILS EMS1 LGR1000 BT485 000 e= o= 0 m & 0 0 0 0 0 U 0 10/100 BaseT Ethernet Port E1 000 DaglyX CMnet Rnet tee Amass 3 Rest Port S2 4e5 D2_T N,+ h Nee- R. Ma DiR Itx Ne OCD Sea GNed ipa:° onnd med. M ,ma met 3V Lithium Battery CR -123A LGR1000 Control Module EnQ Code 0•000e mewl C. MIMI .•Oa.n..d, ev L1r 5DOa�"w aaj eee,r ,enema■ .e" rm M n .AY AMe a� m ® -a • ®a a '-a a.8 ...g 41;1 a.-.B -0 Module State: awnou -sw.• rill I•I LED Nono 0 I�I I AMA 1173 1.4 00000000 Grand cie Poser ImJ On OH EA. Be Dt Be =0 = 0 L I ®I I -1 rannowdd 0 Ponsi l NIA-232 EVF445 oCo Rs TX 0 0 0 0 Open Comm 0 0 towel SCALE = 12" =1' -0" = m BT485I 414'31 SET TOO SET TO 1 T2 12 O 14 O (4) TYP OATH -1 -Temp : 0.2- 0-A101 OATH -1- Humidity : 0- 2- 0-A102 I71 0 0 0 0 mtl +1N 0 0 0 0 0 0 0 0 0 0 0 0 0 RHS-1 - Space Humility : 0.2- 0-A104 ALS-1 - Light Sensor : 0-2-0-A105 16) SPa EF -1 - Status : 0- 2-0- DI07 -< ST -1- Space Temperature : 1- 2-0-AI11 01 0z.«, 0a- 0.N2 0.- 0 3 Na 04 0a 0. 04 03 0. O. 04 0. 0. l0 0 m 0 0 0 0 0 K1 01 0 3 0. 0sram 121 > Light Override 1 - Sales Full On : 0.21 -DI01 O122 >- Light Override 2 - Sales Full Dimming : 0- 2- 1 -D102 ---< 123 > - Light Override 3 - Sales Employee Ltg.. 0- 2- 1- 0103 -< (8) TYP 124 ) Light Override 4 - Unoccupied : 0- 2 -1 -D104 I 25 126) 127 ) Future Override 5 : 0- 2- 1 -D105 Future Override 6 : 0- 2- 1 -D106 Future Override 7 : 0- 2- 1 -D107 Future Override 8 : 02- 1 -DI08 R(PPP. C -# : DESCRIPTION : 0- 2- 1 -DO## DESCRIPTION : 0- 2- 2 -AI## CONTROL POINT LABEL DESCRIPTIONS 0 wee\ 0 R. :\ 0 0 1tl \ a O;N. 0. 0.- 0. 0._ 0, 0.- 0 0 0 0 0 0 0 CONTACTOR #- REFERENCE E301 ONE -LINE DIAGRAM CONTROL POINT DESCRIPTION BACNET NETWORK NUMBER DEVICE ROUTER NUMBER DEVICE ADDRESS CONTROL TYPE: D- DIGITAL, A- ANALOG, 0- OUTPUT, I- INPUT CONTROL POINT NUMBER ON BOARD , 0a 0 4 Ne 0. 0 a 0 0 0 m RTU BACNET NETWORK ' C ) ME812U ( ) ( ) DESCRIPTION MANUFACTURER 1. QTY 2N C�tk ew,aw Power arvw 06 Im I ee.o.w. O 1 'SENSOR, NON ADJUST TEMP CO2 SENSOR- 0- 2000PPM 4-20MA TELAIRE 8.. 3m.,.. .,4..vre = Serra eery ' 011 On Dn0' , �I�, Q 1 end +n ROOM HUMIDITY SENSOR 2% 4 -20MA OR O-5VDC BAPI BAIH200 -R Paver Nall N,� o, RIM LED ROOM TEMPERATURE 4 -20MA (EQUIPMENT RM) J 4!14'70 1=1M8705 - IM e t 317 Lltltum O CR42 6 at Be .9,0 1_ +I „Left Feed BrerCod r BAC met' av D..,m. '® " 7. -\_ 3.o.mma , ,.cmran wn&Br .R40 .� .� . =Ewes, Ed...l,m.rt ® ®- Module Address ® ® ® ® ® 0 CID ® >~ 8>0iblui. .0 .° O -0 -0 - 0 -0 * , J 7 liii sii �,D,,,. endd M2V ,Da Xne, Remote Expansion F ® ICI I ® I 1 �".l !® ®I ®I oa Ne LE12100 1 I.m- ilk .:e"� ME812u r ®,.�;IE I LDIM2 14 CONTROLMODUER oa • ®Il® La II:ICI - II OS aeNa SIT IMI I CUD I o N.a 84'18 0 7. I ®I ED c I EEO __ ,N1 _ WM I I i I • I• w • I /I\ • N4 ::® O j i l t Untael, Input ... .LID Merle Beled omm otwee Pow . P1 1 1:13 I lX)8 1 ` • N,: vv. 110.7 , 4a OW suave: m emnmoa U0-8 , Or 14 _ �ae174I l. ..m. U06 , U0.4, NV mace mg , UO2, 24V00 29Vd4 .,.mwaroe U0-1 , option DR., m O Y.blal 2110c omn I 1 < ) < ) ( ) 1 MEX88U ) Rohm Per III DB I ®I �. ., emr'trn 3cor4 %e,n 2, Vde 24 Vdc 00000000 I: ©:I I•�•I EH �� 041,0■04 %,.t 4yo.wm 40940 IRA 60/ as oro . 149 aea" 41St RM M4 041 ID ':0 win: 0101. 11'rw°pe "�OO�iOnr Module Address e:4 unNen. rut oaa P1- Me se,et ea. tae a as One 1s RID I ®1 U04 uoa 00-2 0o-, r•1 0 0 III ICUI 1 ®1 I ® I 1 ®1 I ®1 1 ® 1 IEmoI MEx88u CONTROL MODULE S S S S S S S sEr ro 1 O.ea.use C ) . e Lei • L10.3 I SET TO 2 I I SET TO01 0 0 9 0 0 B 0 0l r ____ ✓ CT -A CT -A I I I I r - 1 I I I CT -AD 11+ 11- 12+ 12- 13+ 13- Power Meter +CC) 0606 CTS: EC SHALL RUN MAIN FEEDS THROUGH PREWIRED C/TS. Eli -PRTL I I COMO 0 0 0 0 0 0 0 0 0 0 0 CID �. mil 12477 B 0-- T6 ..e EQ -PRTL a.m. ©O • OD m 0 -0 -0 .0 -0 -0 -0 e • (TYP.) C -1,C2: Valance and Trade Ltg : 0- 2- 0-0008 C-3, C-4, C-5 : Unear sales Ltg : 0-2-0-0007 < 19 I C-6 : Linear Sales Ltg Perimeter : 0-2-0-D006-< 18 I O C-7 : Linear Pre -Sales Ltg : 0- 2-0-D005 ( 17 I 2 C-8 : Vestibule / Cust Ltg : 0-2.O -0004 ( 16 I Group 1 : Dimming Ballasts : 0- 2 -0-A003 < 15 I O Group 2 : Dimming Ballasts : 0- 2- 0-A002 < 14 I O Group 3 : Dimming Ballasts : 0- 2-0-A001 ©(3) TYP 1 0 2 0 3 0 T3 In] SET TOO SET TO 3 DEVICES FOR FIELD INSTALLATION, BY EC (PROVIDED BY CSUSA) ID DESCRIPTION MANUFACTURER PART NUMBER QTY ALS -1 EXTERIOR LIGHT SENSOR GREYSTONE PSR -I -T -E 1 'SENSOR, NON ADJUST TEMP CO2 SENSOR- 0- 2000PPM 4-20MA TELAIRE 8001 2 OATH -1 OUTDOOR TEMP & HUMIDITY 4 -20MA VAISALA HMD60Y0 1 RHS-1 ROOM HUMIDITY SENSOR 2% 4 -20MA OR O-5VDC BAPI BAIH200 -R 1 ST -1 ROOM TEMPERATURE 4 -20MA (EQUIPMENT RM) ACI A/TT1 K-3 -R-4 1 4-SWITCH ASSEMBLY- LIGHTING OVERRIDE ECLIPSE 4B-OL 1 CT-B CURRENT TRANSDUCER 0.75- 200AMP (EF-1 STATUS) VERIS IND. H600 1 RTU DEVICES (PROVIDED BY RTU MANUF.) ID DESCRIPTION MANUFACTURER PART NUMBER QTY BACNET BACNET COMMUNICATION BOARD- FACTORY MTD. LENNOX 39W75 +-14 T-STAT 'SENSOR, NON ADJUST TEMP LENNOX 94L60 +-14 1 EMS - LAN GATEWAY AUTOMATED LOGIC LGR1000 *- INSTALLED BY EC. +- QUANTITY IS (1) PER RTU. DEVICES FOR FACTORY INSTALLATION (PROVIDED BY CSUSA) ID DESCRIPTION MANUFACTURER PART NUMBER QTY CT-A CURRENT TRANSDUCER 5-1200 AMP VERIS IND. H681- 2- 1200 -1V 3 POWER METER- 277/480V 3 PHASE, 1200A VERIS IND. H8437VB 1 EMS - LAN GATEWAY AUTOMATED LOGIC LGR1000 1 EMS- ME CONTROLLER AUTOMATED LOGIC ME812U 1 EMS- EXPANDER MODULE AUTOMATED LOGIC MEX88U 2 EMS- EQUIPMENT PORTAL AUTOMATED LOGIC EOPRTL 1 PS -1 POWER SUPPLY 100VA RIB PSB100ABIO I TR -1 TRANSFORMER 120V/24V, 96VA WITH CB DYNACON LE12100 1 DIMMING BALLAST TRANSDUCER KELE LDIM2 3 1 H EMS PANEL POWER - N 120 VAC - - - - - G LA-42 (TYP) 00 e 120 VAC 24VAC l?J PS-1 120 VAC AUX >-0-9 : Pendant (3) Lighting : 02- 1 -DO08 >-C-10 : Pendant (3) Lighting : 0-2 -1 -0007 35 I >-C-11 : Pendant (3) Lighting : 0- 2- 1 -D006-< 34 I )-C-12 : Pendant NL ltgheng: O-2- 1-D005 ( 33 I >- C-13 Security Lighting : 0-2 -1 -0004 < 32 I }- C-14 : Exterior Lighting : 0-2 -1 -0003 < 31 1. x02 m >- C-15 : Elderior Signage : 0- 2 -1 -D002 < 30 1 026 1 \uo-1 EF -1 : S/S : 0- 2-1 -D001 6 ENERGY MANAGEMENT SYSTEM (EMS EMS1 SCALE = NTS (8) TYP 0 4 -0 5 0 6 4 13 I SEE LDIM DETAIL -0 7 0 8 0 T1 1 T2 (HILL- PHOENIX IS RESPONSIBLE FOR MOUNTING AND INTERNAL WIRING OF EMS SYSTEM AS SHOWN, TYPICAL, U.N.O.) KEY NOTES 0 FOR A LOOP - POWERED 0 -5VDC, 0- 10VDC, OR 4 -20 mA SENSOR, WIRE THE SENSOR'S POSITIVE TERMINAL TO THE + TERMINAL ON THE CONTROLLER'S AUX POWER OUT PORT. WIRE THE SENSOR'S NEGATIVE TERMINAL TO ANALOG INPUT + TERMINAL. V+ 0 -5vdc 0 -10vdc 4 -20mA n/c 2 WIRE DEVICE Out V+ 0 5vdc OUt 0- 10vvdcc -20 3 WIRE DEVICE + Any Input GND + Any Input GND _0AUX POW ER 24vdc SET INPUT JUMPER FOR mA OR VOLTS VOLTS 00 00 • • mA • • 0 0 00 ® DIGITAL OUTPLifb I-UK LIGHTING GUN I ! `..iL SHALL BE . PREWIRED IN POWERWALL TO PILOT RELAYS, PROVIDED AND INSTALLED BY HILL - PHOENIX. O GENERAL DIMMING LINEAR FLUORESCENT SALES LIGHTING, (TYPICAL CIRCUITS CORRESPONDING TO CONTACTORS 'C -3', 'C-4', AND'C -5'.) I 14 > (0- 2-0-A002) SHALL CONTROL DIMMING FOR ALL LINEAR FLUORESCENT NIGHT LIGHTS, (SEE "NL" DESIGNATIONS ON E102 FOR FIXTURE LOCATIONS AND QUANTITIES) (0- 2-0-A003) SHALL CONTROL DIMMING PERIMETER LINEAR SALES LIGHTING, (TYPICAL CIRCUITS CORRESPONDING TO CONTACTOR 'C -6'). SEE POWER WALL SITE SPECIFIC INSTALLATION DRAWINGS FOR LOCATIONS AND DESIGNATIONS. 0 EC SHALL PROVIDE CONDUIT STUB TO DECK FOR OWNER PROVIDED ETHERNET CONNECTION, SEE NOTE #10. RTU -14 BACNET T -STAT 0 -1017 BALLAST 0 -1017 BALLAST 0 -1017 BALLAST NOTES: 1 THE EC (EXCEPT AS NOTED) SHALL FURNISH ALL CONDUITS AND LOW VOLTAGE CABLE. EC SHALL INSTALL ALL EMS CONTROL CABLE IN W CONDUIT IF CABLE IS INSIDE BAR JOISTS OR INSIDE WALLS AS REQUIRED BY CODE. 2. THE EC (EXCEPT AS NOTED) SHALL INSTALL THE COMFORT SYSTEMS USA (CSUSA) SUPPLIED FIELD DEVICES AND CONNECT TO HILL - PHOENIX INSTALLED CONTROL BOARD, LOCATED IN POWER WALL. 3. THE EC SHALL MAKE ALL FINAL TERMINATIONS FROM CONTROL BOARDS TO ALL REMOTE EQUIPMENT. 4. CSUSA IS TO PROGRAM AND PERFORM FINAL SYSTEM CHECKOUT. 5. THE ENERGY MANAGEMENT SYSTEM (EMS) SHALL BE FACTORY INSTALLED BY HILL PHOENIX. THIS SHALL INCLUDE ALL INTERNAL INTERCONNECTIONS AS SHOWN. 6. ZONE TEMPERATURE SENSORS SHALL BE FURNISHED WITH ROOFTOP UNITS. SENSORS ARE TO BE MOUNTED BY THE EC AND SHALL BE WIRED FROM THE ROOFTOP UNIT TERMINAL STRIP TO THE SENSOR LOCATION BY THE EC. 7. ALL CONNECTIONS BETWEEN THE ENERGY MANAGEMENT SYSTEM (EMS) AND INDIVIDUAL RTU'S SHALL BE FIELD INSTALLED BY THE EC. 8. ALL LOW VOLTAGE CABLE SHALL BE PROVIDED AND INSTALLED BY EC AND PER WIRE SCHEDULE, AS SHOWN. 9. ALL INQUIRES AND /OR QUESTIONS PERTAINING TO THE ENERGY MANAGEMENT AND CONTROL SYSTEM AND OR SCHEDULING SHALL BE DIRECTED TO: COMFORT SYSTEMS USA / EASTERN HEATING & COOLING CONTROLS DIVISION 880 BROADWAY ALBANY, NY 12207 -1316 (518)- 465 -8878 10. ETHERNET CONNECTION (PROVIDED BY OWNER) MUST BE DEMONSTRATED AS OPERATIONAL PRIOR TO SCHEDULING SITE VISIT WITH COMFORT SYSTEMS USA. OWNER'S I.T. REPRESENTATIVE MUST SUPPLY A STATIC IP ADDRESS PRIOR TO START UP. 11. A COMFORT SYSTEMS USA REPRESENTATIVE WILL BE SCHEDULED ON SITE ONE (1) DAY TO PERFORM THE SYSTEM DOWNLOAD AND START -UP IN ACCORDANCE WITH THE NATIONAL AGREEMENT BETWEEN CSUSA AND TRU. THIS TRIP IS SCHEDULED BY CSUSA FOR THE WEEK FOLLOWING THE STORES FIXTURE/TURNOVER DATE. PLEASE NOTE: TECHNICIANS REPRESENTING THE ELECTRICAL AND MECHANICAL TRADES MUST BE ON SITE DURING SYSTEM DOWNLOAD AND START -UP TO ASSIST IN RESOLVING ANY ISSUES THAT MAY BE DISCOVERED AT THAT TIME. IF THE CSUSA REPRESENTATIVE CANNOT COMPLETE THEIR WORK DUE TO THE ELECTRICAL AND /OR MECHANICAL CONTRACTORS WORK NOT BEING COMPLETE, CSUSA WILL INVOICE TRU FOR AN ADDITIONAL TRIP, OR TIME ON THE JOB. WIRE SPECIFICATIONS dfl #12 AWG THHN #A30008 (MAGNUM CABLE) OR EQUAL, 18/2 AWG TWISTED PAIR, PLENUM RATED, UNSHIELDED, CLASS 2 WIRING WIWHITE JACKET RTU -3 BACNET #A3-ARC-156-2 (MAGNUM CABLE) OR EQUAL, 22/2 AWG TWISTED/ SHIELDED PAIR, PLENUM RATED, CLASS 2 WIRING W /GREEN JACKET #A30009 (MAGNUM CABLE) OR EQUAL, 18/3 AWG TWISTED PAIR, PLENUM RATED, UNSHIELDED, CLASS 2 WIRING W/WHITE JACKET 4 RTU -2 RTU -1 T -STAT LINEAR SALES 0 -10V BALLAST BACNET T -STAT BACNET DEMAND CONTROL VENTILATION SET UP FOR SUPER SIDE BY SIDE TRU /BRU CO2 SENSORS NEED TO BE WIRED INTO RTU AT TERMINAL STRIP AS SHOWN ON SHEET EMS-1. (DCV MAXIMUM DAMPER OPENING POINT) TO A SET POINT DETERMINED BY THE TEST AND BALANCE CONTRACTOR PER THE CFM's SCHEDULED ON THE RTU SCHEDULE, PRIOR TO COMFORT SYSTEMS USA(CSUSA) ARRIVING ON SITE. THE PARAMETER IS SET UP IN PERCENTAGE WHICH IS THE ELECTRICAL SIGNAL GOING TO THE DAMPER ACTUATOR THAT DRIVES IT UP 100% OPEN (THAT DOES NOT EQUATE TO THE PERCENT OF OUTSIDE AIR ENTERING THROUGH THE DAMPER. (DEFAULT) (DCV START OPENING POINT) SHOULD BE AT A CO2 SET POINT OF 500PPM. (DCV MAXIMUM OPENING POINTIF PPM EXCEEDS SETPOINT) SHOULD BE ATA SETPOINT OF 1200PPM. DAMPER SHALL BEGIN OPENING AT 500PPM AND REACH THE FULLY OPEN POINT AT 1200PPM. THESE SETTINGS WILL ALLOW OUTSIDE AIR DAMPER TO MODULATE BETWEEN MINIMUM POSITION AND MAXIMUM POSITION TO MAINTAIN CO2 LEVEL SETPOINT. TEST AND BALANCE REQUIREMENTS THE TEST AND BALANCING CONTRACTOR SHALL ADJUST THE OUTSIDE AIR DAMPER POSITION AND MEASURE THE OUTSIDE AIR CFM TO ACHIEVE THE MINIMUM AND MAXIMUM VENTILATION RATES INDICATED ON THE RTU SCHEDULE, PRIOR TO (CSUSA) ARRIVING ON SITE. THE TEST AND BALANCING CONTRACTOR SHALL SET THE MINIMUM OA DAMPER POSITION USING THE 0- 100% MINIMUM POSITION POTENTIOMETER ON THE LENNOX ECONOMIZER BOARD. ADJUST THE OA DAMPER TO THE REQUIRED POSITION TO OBTAIN THE MAXIMUM VENTILATION CFM RATE. THEN, USING THE LENNOX IMC BOARD, RECORD THE DAMPER POSITION (PERCENT OPEN) CORRESPONDING TO THE MAXIMUM VENTILATION AND FORWARD TO (CSUSA), THIS DAMPER POSITION WILL BE PROGRAMMED INTO THE SYSTEM BY (CSUSA). NOTE: DAMPER PERCENT OPEN DOES NOT EQUATE TO OUTSIDE AIR PERCENT OF SUPPLY AIR. DAMPER POSITIONS MUST BE DETERMINED THROUGH APPROVED TEST AND BALANCE PROCEDURES. T -STAT LIGHT FIXTURES (GROUP 1) LINEAR SALES 0 -10V BALLAST LINEAR SALES 0 -10V BALLAST 0 -10V BALLAST 0 -10V BALLAST LIGHT FIXTURES (GROUP 2 0 -1017 0 -1017 BALLAST 'BALLAST LIGHT FIXTURES (GROUP 3 0 -1017 0 -1017 BALLAST BALLAST 4 Override Switches 4 SETS I-2-1-N ROOF MTD ASSEMBLY 6,-02 SETS 2 SETS OUTDOOR LIGHT SENSOR (ALS -1) OUTDOOR TEMP./ HUMID. SENSOR (OATH -1) EXHUAST FAN (EF -1) EQUIP. RM TEMP (ST -1) 1 EMS POWER METER C/T'S POWER WALL (PROVIDED BY HILL- PHOENIX) SPACE HUMIDITY (RHS -A) EC SHALL RUN MAIN FEEDS THROUGH PREWIRED C/T'S. EMS ONE -LINE ECLLISPERREISPPHOENSIBILMFOZNCEONNTNSECTIT CAL, UN.O.) ELATION OF EMS1 SCALE = NTS RECEIVED MAR 112010 PERMIT CENTER CONSTR. DOC & REVISIONS NO. DATE 03/OSNO NO. DATE 03/08/10 DESCRIPTION DESCRIPTION ISSUED FOR BIDS & PERMITS ISSUED FOR BIDS & PERMITS PROTOTYPE UPDATES NO DATE DESCRIPTION 0 10/28/09 2010 58K REV. 0 BID DATE: 03/09/2010 PROJECT NO.: 55252805 DRAWN BY: JJK CHECKED BY: CARP PROTOTYPE DESIGNATION: SSBS 58K PROTOTYPE PAGE ENGINEERS & CONSULT NTS 923 MAIN STREET. N. WILKESBORO, NC 28659 PHONE 336 - 6674225 FAX: 336 -667 -4332 STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION TUKWILA, WA DRAWING TITLE ENERGY MANAGEMENT SCALE As indicated ISSUE DATE MARCH 9, 2010 SHEET NO. EMSI AR v i. Q� 4) Cif I/o ' . „ cv 2? (O �Q ,/j?,&I Q� C OJT O= X4;7 O'`4/ VO= k�� k S „- 4' �� J� �� V� FIRE ALARM MATRIX �� p�� °J� �� � °� s� �° cam° �° � „it: X44, ��� �� Q J�O ��� ��� ,`O� Q" QQv �p�� �O Z �O <c� Q V Q Q J ";:;E;;:f:f" =� -4 -C. =� \\p �\O= ��O ZQ \C.)\V � = �� p� V° 2� � O� ct- S� �� C�� OJ JQV' �p�� c C9 - J g�- ��p <ZR- � tV ko � IA' co ,``CO co �V QV�• o vt- FIRE SPRINKLER SYSTEMS - WATERFLOW SWITCH 0 • • • • • - CONTROL VALVE TAMPER SWITCH • • • MANUAL PULL STATIONS • • • • • • SMOKE DETECTION DEVICES - ABOVE FACP • • • • • • LOSS OF PRIMARY POWER AT THE FACP OR APS • • • ABNORMAL CIRCUIT OR DEVICE • • • 38' -0° 38,- 4 ) 38' -0" 38' -0" FIRESTOP NOTES ALL THROUGH - PENETRATIONS OF FIRE -RATED WALLS AND FLOORS SHALL BE FIRE- STOPPED. 2. FIRE -RATED GYPSUM BOARD WALLS CONSTRUCTED AS DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGNS IN THE U.L. FIRE RESISTANCE DIRECTORY (GENERALLY DOUBLE THICKNESS WALLBOARD) SHALL BE FIRE - STOPPED WITH U.L. SYSTEMS. 3. ALL REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT CONCRETE FLOORS OR WALLS, AND ALL U.L. CLASSIFIED CONCRETE BLOCK WALLS SHALL BE FIRE - STOPPED WITH U.L. SYSTEMS. FIREPROOFING NOTES INSTALL ALL HANGERS, CLAMPS, CONDUIT, AND BACK BOXES FOR THE FIRE ALARM SYSTEM PRIOR TO THE APPLICATION OF FIREPROOFING ON STRUCTURAL MEMBERS. 2. INSTALL ALL HANGERS, CLAMPS, AND BACK BOXES FOR THE FIRE ALARM SYSTEM ON THE EDGE OF ANY JOIST REQUIRING FIREPROOFING. BACK BOXES SHALL BE FASTENED TO THE FLANGE OF THE JOIST UTILIZING BEAM CLAMPS, AND SHALL NOT BE ATTACHED DIRECTLY TO THE JOIST. 3. ANY DAMAGE TO FIREPROOFING ON THE BUILDING STRUCTURE AS A RESULT OF THE FIRE ALARM SYSTEM INSTALLATION SHALL BE REPAIRED BY A QUALIFIED FIREPROOFING CONTRACTOR. ALL DAMAGE AND REPAIR OF FIREPROOFING SHALL BE REPORTED TO AND COORDINATED THROUGH THE GENERAL CONTRACTOR. THE FIRE ALARM CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIREPROOFING REPAIRS AT NO ADDITIONAL COST TO THE OWNER. 4. VERIFY THE LOCATIONS OF ALL FIREPROOFING, PRIOR TO THE INSTALLATION OF ANY FIRE ALARM CONDUIT AND BACKBOXES. 37' -11" 38' -3' INSTALLATION NOTES 1. THE GENERAL CONTRACTOR (GC) IS ULTIMATELY RESPONSIBLE FOR THE FIRE ALARM SYSTEM AS DESCRIBED IN THE SPECIFICATIONS ANDON'THESE DRAWINGS. THE FIRE ALARM CONTRACTOR IS TO BE CONTRACTED THROUGH THE GC. THE OWNER IS NOT RESPONSIBLE FOR ANY PART OF THE FIRE ALARM SYSTEM. 2. SEE WIRING LEGEND FOR CABLE TYPES AND SIZES. 3. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA STANDARDS AND ALL LOCAL ADOPTED CODES. 4. CABLE ROUTING SHOWN ON DRAWINGS IS FOR INTENT. EXACT ROUTING SHALL BE COORDINATED WITH OTHER TRADES IN THE FIELD. FOLLOW SPECIFICATIONS AND DRAWING NOTES FOR SPECIFIC AND ACCEPTABLE INSTALLATION METHODS. 5. ALL CABLE RUNS SHALL BE NEATLY BUNDLED, WRAPPED TIGHT AND PROPERLY SECURED. ANY CABLING NOT INSTALLED IN A NEAT AND PROFESSIONAL MANNER SHALL BE PULLED OUT AND RE -RUN BY INSTALLER AT NO ADDITIONAL COST TO THE OWNER. 6. CONTRACTOR RUNNING CABLING MUST MARK BOTH ENDS OF CABLING, PROVIDE A WIRE LEGEND FOR ALL LOCATIONS, AND PROVIDE A CONTINUITY TEST LOG FOR EACH CABLE. 7. EXPOSED CABLING SHALL BE RUN PARALLEL AND PERPENDICULAR TO STRUCTURE. EXPOSED CABLING SHALL NOT BE RUN IN A "SPAN" FASHION BETWEEN BAR JOISTS OR BEAMS (I.E.: CABLING SHALL BE ROUTED ALONG PATH OF JOISTS AND BEAMS). ALL CABLING SHALL BE SECURED TO THE STRUCTURAL CEILING BETWEEN JOISTS OR BEAMS, AND AS INDICATED IN SPECIFICATION SECTION 16F. -F(AV06) I F(AV04) (AV04) F(AV04) JL 4 M i1 mm 7 !I1!f ! Ilia r3 a: fill KUM II Isom ■,row m . fiammi [[CC! ■ MI wrn n� 8. ALL CABLING SHALL BE SUPPORTED FROM BUILDING STRUCTURE AND NOT FROM GRID, TILES OR SUPPORT WIRES. EXPOSED CABLING SHALL BE SUPPORTED BY BUILDING STRUCTURE AT NO MORE THAN FIVE (5) FOOT INTERVALS. 9. PROVIDE ANY REQUIRED CONDUIT, BACK BOXES, AND FITTINGS FOR THE FIRE ALARM SYSTEM CABLING. 10. PROVIDE RED JUNCTION BOX COVERS FOR ALL SYSTEM BOXES. ALL JUNCTION BOXES AND CABLE SPLICES SHALL BE IN ACCESSIBLE LOCATIONS. PROVIDE ANY REQUIRED ACCESS PANELS. 11. ALL CABLING IN ELECTRICAUMECHANICAL ROOMS, AND AREAS SUBJECT TO PHYSICAL DAMAGE SHALL BE INSTALLED IN EMT CONDUIT. 12. FIRE ALARM CABLING SHALL NOT BE PAINTED. 13. ALL WIRING CONDUCTORS FOR THE FIRE ALARM SYSTEM SEVEN (7) FEET OR LESS ABOVE THE FINISHED FLOOR, CONCEALED IN CEILINGS OR PARTITIONS, SUBJECT TO PHYSICAL DAMAGE, NON -POWER LIMITED, OR WHERE REQUIRED BY APPLICABLE CODES SHALL BE INSTALLED IN CONDUIT. 14. ALL FIRE ALARM CABLING RISERS SHALL BE INSTALLED IN EMT CONDUIT. 15. COORDINATE DRILLING OF ANY HOLES (I.E. COLUMN PENETRATIONS) WITH THE GENERAL CONTRACTOR AND ALL OTHER TRADES PRIOR TO INSTALLATION. IT SHALL BE ACCEPTABLE TO DRILL A SINGLE 1/2" HOLE IN THE UPPER AND LOWER THIRD OF THE COLUMN. HOWEVER, THE MIDDLE THIRD OF ANY COLUMN SHALL NOT BE DRILLED. 16. THE FIRE ALARM CONTRACTOR SHALL CONTRACT AND COORDINATE THE SERVICES OF A BOSCH SECURITY SYSTEMS CERTIFIED SECURITY DEALER (BCSD) FOR THE PURPOSE OF INSTALLING, PROGRAMMING AND TESTING OF THE FIRE ALARM CONTROL PANEL AS WELL AS TESTING OF THE COMPLETE FIRE ALARM SYSTEM. IN THE SPECIFIC INSTANCE WHEN THE FAC CANNOT LOCATE A BCSD IN THE AREA, CONTACT WAYNE BIDWELL WITH BOSCH SECURITY SYSTEMS BY PHONE AT (734) 255 -5500 FOR COORDINATION. 17. THE FIRE ALARM CONTRACTOR SHALL COORDINATE THE SERVICES OF A TECHNICAL REPRESENTATIVE FROM VECTOR SECURITY FOR THE SOLE PURPOSE OF ESTABLISHING MONITORING WITH THE UL LISTED OFF -SITE MONITORING STATION. CONTACT ERICKA MACLEOD, WITH VECTOR SECURITY, BETWEEN THE HOURS OF 8 AM AND 5 PM EST BY PHONE AT (703) 369 -1444 EXT. 51150 OR BY FAX AT (206) 339 -3594 FOR COORDINATION. 18. THE FIRE ALARM CONTRACTOR SHALL FAX THE FIRE ALARM PANEL WORKSHEET TO THE VECTOR SECURITY TECHNICAL REPRESENTATIVE A MINIMUM OF FIVE (5) BUSINESS DAYS BEFORE THE SYSTEM IS SCHEDULED TO GO ON -LINE. THE FIRE ALARM SYSTEM, INCLUSIVE OF TELEPHONE CONNECTIONS, SHALL BE INSTALLED AND WORKING PRIOR TO CONTACTING VECTOR SECURITY. CONTACT VECTOR SECURITY AGAIN ON THE MORNING OF, OR THE DAY BEFORE, THE FIRE ALARM SYSTEM IS SCHEDULED TO GO ON -LINE. 19. THE FIRE ALARM CONTRACTOR SHALL PROVIDE TRAINING OF AVAILABLE TRU -BRU STORE MANAGEMENT STAFF ON SYSTEM OPERATION. -F(AV06) 2E(DL) F(AV06) F(AV06) B.O.D. = 21'-8" I'j(AV04) CN 2F(AV03 -04) (AV03 -04) 2F(AV03 -04) 2F(AV03 -04 2F(AV03 -14) E(DL) F(AV02) F(A 02) (AV02) F(AV02) (AV02) W21 2E(DL) 2F(AV05- 3F(AV02 -14) Y. iNealt B.Q.D. = 21' -10" B.O.D. = 22' -9" B.O.D. = 23' -8" B.O.D. = 24' -6" AV01 E(DL) E(DL) F(AV01 j- (DL) F(AV01) F(A 01) E(DL) 2E(DL) 2F(AV05- (7 B.O.D. titer ■I i : I 1 (11■ i ■ ■■ :I: ■■ 71IIII000 U■UUUU t■■u� ■ iiJ ■ ■ ■ ■IC ■A1■■■ 1■■■■■U11' D(AN) E(DL) FA101 D(AN) E(DL) 05) F(AVEX) 4F (AV01 -04) E(DL) a FIRE ALARM PLAN - SCALE: ' /16" =1' -0" _D ET rum ,..... . Fr sEmnain, i IF1,1 I� IS mo dwriarr-TrAl W Z• ID ar D(AN) E(DL) `, 2E 133 D(AN) E(DL) 2F(AV05) DL) D(AN) (DL) F(AVO ) F(AVEX) F(AVEX) F(AV05) AVEX B.O.D. = 25' -4" DL) V05 -06) 2E(DL) ' 2F(AV05-06 GENERAL NOTES 1. COORDINATE CONNECTION OF SPRINKLER WATERFLOW SWITCHES, TAMPER SWITCHES & BACKFLOW PREVENTER VALVE TAMPER SWITCHES WITH THE SPRINKLER CONTRACTOR. PROVIDE CABLING FROM FACP TO SPRINKLER SWITCHES, FINAL WIRING TERMINATIONS AT SWITCHES, AND SUPERVISION OF ALL WIRING CONNECTIONS. COORDINATE WITH SPRINKLER CONTRACTOR TO VERIFY A THIRTY (30) SECOND RETARD ON FLOW SWITCHES. 2. DUCT DETECTORS ARE NOT REQUIRED ON THE ROOF TOP UNITS THAT ARE INCAPABLE OF SPREADING SMOKE BEYOND THE ENCLOSING WALLS, FLOORS AND CEILINGS SERVED BY THE UNIT. 3. MOUNT SMOKE DETECTORS AT THE CEILING /DECK, AND NOT ON THE BOTTOMS OF BEAMS OR JOISTS. LOCATE ALL SMOKE DETECTORS A MINIMUM OF THREE (3) FEET FROM ANY MECHANICAL DIFFUSERS, AND AS REQUIRED BY NFPA 72. COORDINATE SMOKE DETECTOR LOCATIONS WITH LIGHTING, MECHANICAL, SPRINKLER, & BACKGROUND MUSIC EQUIPMENT. 4. SMOKE DETECTOR HEADS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN -UP OF ALL TRADES IS COMPLETE AND FINAL. 5. COORDINATE EXACT PLACEMENT OF ALL DEVICES WITH THE ARCHITECTURAL FIXTURE PLANS, OWNER, AND GENERAL CONTRACTOR PRIOR TO INSTALLATION. 6. PROVIDE TWO (2) MEANS OF SIGNAL TRANSMISSION TO THE VECTOR SECURITY OFF -SITE MONITORING FACILITY FOR MONITORING OF GENERAL ALARM, SUPERVISORY, AND TROUBLE CONDITIONS. 7. PROVIDE ANY REQUIRED SEISMIC BRACING FOR ALL FIRE ALARM SYSTEM DEVICES, CONDUIT, AND BACKBOXES. KEYED NOTES 0 COORDINATE CONNECTIONS TO DEDICATED 120 VAC POWER CIRCUITS TO THE FACP, EACH APS, AND CPS. IDENTIFY THE LOCATION OF THE CIRCUIT DISCONNECT AT THE ASSOCIATED FACP AND APS. LABEL THE DEDICATED CIRCUITS "FIRE ALARM CIRCUIT(S) ". PROVIDE TWENTY -FOUR (24) HOUR BATTER`( BACKUP IN THE FACP AND EACH APS. COORDINATE ALL CONNECTIONS WITH THE ELECTRICAL CONTRACTOR. O COORDINATE EXACT MOUNTING LOCATION OF FIRE ALARM CONTROL PANEL (FACP) WITH THE GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION. SEE ELECTRICAL DRAWING E01. O PROVIDE DEDICATED PHONE WIRING FROM FACP TO MAIN TERMINAL BOARD FOR PRIMARY AND SECONDARY OFF -SITE MONITORING. COORDINATE FINAL CONNECTIONS ON MAIN TERMINAL BOARD. O PROVIDE A REMOTE FIRE ALARM ANNUNCIATOR (FAAN) AS SHOWN ON DRAWINGS AND AS INDICATED IN SPECIFICATION SECTION 16F. COORDINATE EXACT MOUNTING LOCATION OF FAAN WITH THE GENERAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. • PROVIDE A SIGNAL TO SHUTDOWN THE STORE BACKGROUND MUSIC SOUND SYSTEM UPON ACTIVATION OF A FIRE ALARM CONDITION. PROVIDE CABLING FROM FACP TO BACKGROUND MUSIC SOUND SYSTEM CONTROLLER, AND SUPERVISION OF ALL WIRING CONNECTIONS. COORDINATE INTERFACE CONNECTIONS WITH THE SOUND SYSTEMS CONTRACTOR. ® MOUNT THE EXTERIOR WATERFLOW NOTIFICATION APPLIANCE ABOVE THE FIRE DEPARTMENT CONNECTION AT TEN (10) FEET ABOVE GRADE. COORDINATE THE EXACT MOUNTING LOCATION WITH THE GENERAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. 0 MOUNT SMOKE DETECTOR ON THE BOTTOM OF THE CEILING /DECK (NOT ON THE BOTTOM OF STRUCTURAL MEMBERS) AND LOCATED MORE THAN THREE (3) FEET FROM AIR SUPPLY DIFFUSERS, AS INDICATED IN NFPA 72. COORDINATE SMOKE DETECTOR LOCATIONS WITH LIGHTING, MECHANICAL, AND SPRINKLERS. �8 DUCT DETECTORS ARE NOT REQUIRED PER THE EXCEPTION IN SECTION 606.2 OF THE 2003 INTERNATIONAL MECHANICAL CODE (IMC). THE RTUS ARE NOT CABLE OF SPREADING SMOKE BEYOND THE ENCLOSING WALLS, FLOORS AND CEILING. �9 PROVIDE PROTECTIVE COVERS ON ALL COMMON AREA PULL STATIONS. PROVIDE COVERS WITH INTEGRAL HORN. (AN) (DL) F(AV01 -0 F(AV05) (AVEX) 0 M FIRE ALARM SYMBOL KEY FACP - FIRE ALARM CONTROL PANEL (BOSCH FPD- 7024) FAAN FIRE ALARM ANNUNCIATOR (BOSCH FMR -7036) AUXILIARY POWER SUPPLY (WHEELOCK PS- 24 -8MP) ADDRESSABLE INPUT MODULE (BOSCH D7044 OR D7052) ADDRESSABLE INPUT /OUTPUT MODULE (BOSCH D7053) MANUAL PULL STATION (BOSCH FMM- 7045 -D) WITH PROTECTIVE COVERS OS PHOTOELECTRIC SMOKE DETECTOR (BOSCH D7050) FS FLOW SWITCH (BY OTHERS) TS TAMPER SWITCH (BY OTHERS) pS HIGH /LOW AIR PRESSURE SWITCH (BY OTHERS) XX WALL MOUNTED AUDIBLENISUAL APPLIANCE (XX INDICATES CANDELA RATING) (WHEELOCK AS- 24MCW -FR) (RED IN COLOR) IOM I V XX WALL MOUNTED VISUAL APPLIANCE (XX INDICATES CANDELA RATING) �� vv ( WHEELOCK RSS- 24MCW -FR) (RED IN COLOR) AV XX CEILING MOUNTED AUDIBLENISUAL APPLIANCE (XX INDICATES CANDELA RATING) (WHEELOCKAS- 24MCC -FW) (WHITE IN COLOR) OXX CEILING MOUNTED VISUAL APPLIANCE (XX INDICATES CANDELA RATING) (WHEELOCK RSS - 24MCC -FW) (WHITE IN COLOR) WP XX WEATHERPROOF EXTERIOR AUDIBLENISUAL APPLIANCE (XX INDICATES CANDELA RATING) (WHEELOCK ASWP- 2475W -FR) (RED IN COLOR) FIRE ALARM CONDUCTORS END OF LINE RESISTOR WIRING LEGEND CONDUCTOR TYPE: D =18/4 FPL E =18 /2FPL F =14/2 FPL G = AS REQUIRED BY MANUFACTURER H =18/2 FPL WET LOCATION CONDUCTOR TYPE INDICATES TYPE OF CIRCUIT (VISUAL, AUDIBLE, ZONE, ETC.) REFER TO LIST OF ABBREVIATIONS CIRCUIT DESIGNATION: DL = DATA LOOP CIRCUIT ZN = INITIATION ZONE CIRCUIT AV = NOTIFICATION CIRCUIT AN = ANNUNCIATOR KEYPAD CIRCUIT PW = LOW VOLTAGE POWER RT = REMOTE TEST STATION POWER RC = RELAY CONTROL CIRCUIT SU = SUPERVISORY CIRCUIT rum mete �- NM 16� • hi10 2E(DL) r ENLARGED TELCO ROOM FIRE ALARM PLAN SCALE: 1/4" =1' -0" NEW 8" FEED MAIN TO TOY R US NEW PRESSURE GAUGE TIE NEW 2" DRAIN INTO EXISTING DRAIN LINE I DI(AN) k(DL) oiqo D(AN) E(DL) 141 142 140 143 144 wzgraa _ _ F(AVEX) t CONSTR. DOC & REVISIONS NO. DATE DESCRIPTION 03/09/10 ISSUED FOR PERMITS 03/09/10 ISSUED FOR BIDS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 12/14/09 2010 46K REV. 0 FA101 ENLARGED FIRE SPRINKLER AihN 2 , RISER ROOM FIRE ALARM PLAN _ FA10. SCALE 1/4" =1' -0" EXISTING 2" PIPED TO EXISTING 8' FEED MAIN STANDPIPE DRAIN TO TOYS R US EXISTING 2" DRAIN VALVE RELOCATED EXISTING 2" DRAIN RELOCATED EXISTING FLOW SWITCH 4 - 2 1/2" FIRE DEPARTMENT VALVES WITH CAPS AND CHAINS FOR TESTING OF BACKFLOW PREVENTER -� EXISTING 4" FEED MAIN TO EXISTING FRONT CANOPY DRY PIPE FIRE SPRINKLER SYSTEM NEW ECS RISER MOUNT CORROSION MONITORING STATION WITH CORROSION MONITORING PROBE (RCMP -2) (TYP.) EXISTING PRESSURE GAUGE EXISTING 4" DRY PIPE VALVE EXISTING 4" SUPERVISED INDICATING BUTTERFLY VALVE 144 LL POST INDI TING VALVE E(DL) RELOCATED 8" SUPERVISED WALL POST INDICATING VALVE. E(SU) EXISTING 8" FEBCO MODEL 876 DOUBLE CHECK DETECTOR ASSEMBLY BACKFLOW PREVENTER WITH 2 SUPERVISED OS & Y VALVES www.codeconsultants.com ci z CODE CONSULTANTS, art+ I irC)) E(SU) CTC FINISHED FLOOR REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC MAR 19 2010 NEW PIPE STAND NEW 6" FEED FROM EXISTING FIRE DEPARTMENT CONNECTION (EXISTING 6" CHECK VALVE IN HORIZONTAL PLAN EXISTING 8" U.G. ABANDONED FIRE I SERVICE MAIN ) EXISTING PIPE STAND L RELOCATE EXISTING 8" ELBOW WITH NEW 8" TEE DISCONNECT AND CAP EXISTING 6" FEED FROM FIRE DEPARTMENT CONNECTION /-- EXISTING 8" U.G. FIRE SERVICE LEAD -IN FIRE ALARM ELEVATION 3 AT RISER MANIFOLD FA101 SCALE: 3/8" =1' -0" MAINTAIN E INSPECTOR VALVES AN RECEIVED MAR 112010 PERMIT CENTER BID DATE: 03/09/10 DRAWN BY: JLS PROTOTYPE DESIGNATION: PROJECT NO.: 090448.07.000 CHECKED BY: DJB PROTOTYPE DATE: 03/08/10 FIRE PROTECTION DAVID J. BURKHART, P LICENSE NO. 0030980 CODE CONSULTANTS, INC. 1804 NORMAN CIRCLE DR. ST. LOUIS, MO 63146 -4136 PHONE: 314-991-2633 CORPORATE CERTIFICATE OF AUTHORITY NO. 1604 Toys 3 (c) STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW I LA, WA DRAWING TITLE FIRE ALARM PLAN NOTES AND DETAILS SCALE AS INDICATED ISSUE DATE DECEMBER 14, 2009 SHEET NO. FA101 AUDIBLE CIRCUIT AC POWER 3 AC POWER 2 NC AC POWER 1 11E 11E 1111111•= I MK I 1•1•11■1'® 0 SUMO- mo,... • 1.1..,. LILLY 111-11-1 111-11-1 0 NAC 1+ NAC NAC 24 NAC 2-c BAT- BAT+ ❑❑❑❑❑❑❑❑❑ ❑❑❑ 0 0 0 0 EES O 0 D 0 D7039 MUX EXPANSION MODULE ❑ Power ❑ Trouble 0 ❑ Alarm ❑ Silenced SYSTEM NORMAL BOSCH D7024 1 4 7 * , Clear , 2 5 8 0 P9 3 6 9 Cmnd Drill Disable Test History Silence Reset 0 0 FPD -7024 .Y.Y.Y.Y. WAWA. .Y.YA Y.Y. Aveget D7034 CONNECTOR ONLY ..Y.Y.... .Y.Y.Y.Y. VAVAVATAV VAVAVAVAV R2 HR2 HT2 T2 R1 RH1 TH1 T1 NC2 COM2 NO2 NCI COM1 NO1 SMK+ SMK- AUX+ AUX- El El Qa +1 El EARTH GROUND- 4- L+ 3- 2- L+ 1- El C +1 C +1 RA BA GA YA RB BB GB YB SEE NOTE 1 SEE NOTE 3 BATTERY (SEE BATTERY CALCULATIONS FOR REQUIREMENTS) BATTERY (SEE BATTERY CALCULATIONS FOR REQUIREMENTS) SECONDARY PHONE CONNECTION PRIMARY PHONE CONNECTION AUXILIARY RELAY AUXILIARY RELAY SEE NOTE 7 IOM SWITCHED SMOKE POWER AVEX AUXILIARY POWER SUPPLY (APS) (PS -24 -8MP) PO NTS 1- 4 POWER LIMITED 24v INITIATING LOOPS 0 I/O MODULE FOR THE O D7039 MUX EXPANSION MODULE O c 0 O C9 Qa Qa NOTES: MUX Bus "A" IOM NAC 1 NAC 2 NAC 3 NAC 4 1 SYNC MODULE (INTEGRAL TO APS) HORN SEE NOTE 6 CONTROL +• -• +• + tit 120 VAC DEDICATED CIRCUIT • ZONE 1 • IN ••• ZONE 2 • IN ZONE I OUT ZONE 2 OUT - MULTI -SYNC MULTI -SYNC -• • + SLAVE (IN) SLAVE (OUT) +• TYPICAL APPLIANCES ONLY TYPICAL APPLIANCES ONLY SYNC MODULE (INTEGRAL TO APS) HORN SEE NOTE 6 CONTROL ZONE 1 OUT • ZONE 1 IN -S • ZONE 2 IN ZONE 2 OUT ~ - MULTI -SYNC MULTI -SYNC -••- •+ SLAVE (IN) SLAVE (OUT) +•-- TYPICAL APPLIANCES ONLY TYPICAL APPLIANCES ONLY AUXILIARY POWER SUPPLY (APS) (PS -24 -8MP) NAC 1 NAC 2 NAC 3 NAC 4 RED GRN YLW FPD -7036 SILENCE) RESET ) O O O O 0 0 0 • +• • 120 VAC DEDICATED CIRCUIT SYNC MODULE (INTEGRAL TO APS) HORN SEE NOTE 6 ONTROL ZONE I OUT ZONE I • IN • ZONE 2 -• IN ZONE 2 OUT - MULTI -SYNC MULTI -SYNC -6' + SLAVE (IN) SLAVE (OUT)+• - TYPICAL APPLIANCES ONLY TYPICAL APPLIANCES ONLY SYNC MODULE (INTEGRAL TO APS) HORN SEE NOTE 6 EOL CONTROL ZONE 1 OUT 1. CONNECT PRIMARY SIDE OF TRANSFORMER TO DEDICATED 120 VAC, 60 HZ CIRCUIT USING WIRE NUTS. CONNECT EARTH GROUND TO THREADED GROUND STUD ON LEFT SIDE OF ENCLOSURE. 2. PROVIDE ZONE LISTING IN PANEL. 3. PROVIDE CUSTOM "P- TOUCH" LABELS ON SURFACE OF PANEL TO INCLUDE: ALARM SILENCE CODE, RESET CODE, TROUBLE SILENCE CODE, HVAC RESET CODE, ETC. 4. PROVIDE SYNCHRONIZATION ON ALL NOTIFICATION APPLIANCE CIRCUITS. 5. PROVIDE A MULTI -SYNC MODE SLAVE CONNECTION TO ALL SYNCHRONIZATION MODULES ON ALL APS'S. 6. SYNC MODULES ARE INTEGRAL TO APS. NON- INTEGRAL SYNC MODULES ARE ACCEPTABLE. 7. PROVIDE ADDRESSABLE INPUT/OUTPUT MODULE (IOM) FOR ACTIVATION OF AUXILIARY POWER SUPPLY (APS) AND FOR MONITORING OF TROUBLE CONDITIONS ON APS. 8. PROVIDE THE SERVICE PHONE NUMBER STICKER ON THE SURFACE OF THE FIRE ALARM CONTROL PANEL. 9. PROVIDE THE ASSOCIATED PHONE NUMBER WRITTEN DIRECTLY ON THE RJ -31X BOXES. 10. PROVIDE A COPY OF THE FIRE ALARM ZONE LIST POSTED ADJACENT TO THE FIRE ALARM CONTROL PANEL. 11. IF REQURIED BY THE AHJ, PROVIDE SUFFICIENT CIRCUITS AND MODULES TO CONTROL AUDIBLE APPLIANCES SEPARATELY FROM VISUAL APPLIANCES. PROVIDE "ON- UNTIL - SILENCE" PROGRAMMING FOR AUDIBLE APPLIANCES, AND "ON- UNTIL - RESET" FOR VISUAL APPLIANCES. FIRE ALARM PANEL LAYOUT NOT TO SCALE NOTES: 1. ALL OPEN FIRE ALARM CABLING SHALL BE CONCEALED FROM PUBLIC VIEW. OPEN FIRE ALARM CABLING DETAIL NOT TO SCALE SYMBOL LEGEND: C = LIGHT OUTPUT (CANDELA) AT ANGLE B FOR WHEELOCK STROBES (BASED ON CUT SHEETS) 6 = ANGLE OFF THE AXIS D = DISTANCE FROM SOURCE (FEET) L = LIGHT INTENSITY (MINIMUM 0.0375 LUMENS /SQUARE FOOT) (NFPA 72, 1999 APPENDIX SECTION A-4-4 .4.1.1(1)) X = HORIZONTAL DISTANCE OFF THE AXIS (FEET) H = VERTICAL DISTANCE OF LIGHT SOURCE FROM FLOOR (FEET) EQUATIONS: 6 = tan '\ (÷) X =-1 D2 -H2 L = p2 > .0375 HORIZONTAL PLANE FIRE ALARM CABLING DISTANCE CHART H (FEET) X (FEET) 15 CD 30 CD 75 CD 95 CD 115 CD 177 CD 8 13.9 17.2 29.9 29.9 29.9 45.4 9 12.9 19.3 33.6 33.6 33.6 51.0 10 14.3 17.3 37.3 37.3 37.3 37.3 11 13.1 19.1 30.2 41.1 41.1 41.1 12 12.0 20.8 25.7 44.8 44.8 44.8 13 13.0 18.6 27.9 35.7 35.7 48.5 14 11.7 20.0 30.0 38.5 38.5 52.2 15 10.5 17.9 32.2 32.2 41.2 41.2 16 11.2 19.1 27.7 34.3 34.3 44.0 17 9.8 17.0 29.4 36.5 36.5 46.7 18 8.4 18.0 31.2 38.6 38.6 49.5 19 8.9 15.9 27.1 32.9 40.7 52.2 20 7.3 16.8 28.6 34.6 34.6 42.9 21 7.6 17.6 30.0 36.4 36.4 45.0 22 5.9 15.4 31.4 38.1 38.1 47.2 23 2.0 16.1 27.4 32.8 39.8 49.3 24 N/A 13.9 28.6 34.3 34.3 51.5 25 N/A 14.4 29.8 35.7 35.7 43.3 26 N/A 12.1 26.0 37.1 37.1 45.0 27 N/A 12.6 27.0 38.6 38.6 46.8 28 N/A 10.2 28.0 33.4 40.0 40.0 29 N/A 10.6 24.3 34.6 34.6 41.4 30 N/A 10.9 25.2 30.0 35.8 42.8 CEILING MOUNTED STROBE DISTANCE CALCULATIONS NOT TO SCALE WHEELOCK TABLE FOR CANDELA OUTPUT ANGLE 15 CD 30 CD 75 CD 95 CD 115 CD 177 CD 0 20.5 43.3 102.6 146.0 166.7 230.8 5 20.5 43.3 102.6 146.0 161.7 230.8 10 20.1 43.0 102.0 145.0 155.8 217.0 15 20.2 42.7 102.0 145.0 152.3 215.6 20 18.8 40.0 97.1 134.1 140.5 198.1 25 16.9 35.0 85.5 121.3 129.5 185.4 30 15.3 32.7 80.0 111.6 117.4 165.8 35 14.8 31.1 74.0 106.3 109.4 157.4 40 14.1 29.0 70.6 100.7 101.5 152.8 45 12.8 25.9 62.3 90.7 95.3 144.3 50 11.3 23.3 57.1 81.2 86.3 131.1 55 11.9 23.8 57.7 84.5 95.4 141.1 60 11.3 22.3 52.2 78.1 86.1 117.3 65 10.1 20.9 48.9 69.1 82.5 127.0 70 9.7 19.8 44.7 64.7 78.1 127.2 75 12.3 25.0 57.8 81.7 81.3 124.0 80 10.6 21.9 51.3 69.4 75.1 101.0 85 5.4 12.1 28.7 37.2 47.2 69.5 90 7.6 16.6 39.8 49.7 40.5 61.4 y • ZONE 1 IN • ZONE 2 IN '~ - MULTI -SYNC 7 + SLAVE (IN) ZONE 2 OUT MULTI -SYNC -�- SLAVE (OUT) +, SEE NOT 5 TYPICAL APPLIANCES ONLY TYPICAL APPLIANCES ONLY 1 OR 2 HOUR RATED GYPSUM WALLBOARD ASSEMBLY NOTES: 3M FIRE BARRIER FD -150+ CAULK OR EQUAL CABLE OR CABLE BUNDLE LOAD vs DISTANCE CHART NOTIFICATION APPLIANCE CIRCUITS DESCRIPTION APS I CIRCUIT LOCATION MAXIMUM DISTANCE TO LAST APPLIANCE ALARM CURRENT (AMPS) 12 AWG (FEET) 14 AWG (FEET) FACP TELCO ROOM DESCRIPTION QUANTITY CURRENT PER DEVICE (mA) AVEX EXTERIOR CIRCUIT 0.168 5,923 3,732 FPD -7024 FIRE ALARM CONTROL PANEL 1 200 200 I APS #1 TELCO ROOM D7039 AV01 FRONT OFFICE AREA 1.665 685 430 AVO2 SALES FLOOR AREA 1.665 685 430 AVO3 SALES FLOOR AREA 1.665 685 430 AVO4 SALES FLOOR AREA 1.272 896 563 0.55 3.85 0.55 3.85 STANDBY mAH APS #2 TELCO ROOM SMOKE DETECTOR 1 0.50 AVO5 SALES FLOOR AREA 1.132 1,007 633 AVO6 SALES /PRE -SALES AREA 1.414 806 507 AVO7 PRE -SALES AREA 0 0 0 AVO8 SPARE 0 0 0 NOTES: APPLIANCE CIRCUITS (NAC) DESIGNED FORA MAXIMUM 2.0 AMPS, 4.4 VDC DROP, AND MINIMUM OPERATING VOLTAGE OF 16.0 VDC. ALL VOLTAGE DROP AND POWER REQUIREMENTS. HAVE BEEN DESIGNED BASED UPON WHEELOCK CIRCUIT AND VOLTAGE CRITERIA. IF ALTERNATE NOTIFICATION APPLIANCES PROVIDE REVISED POWER AND VOLTAGE DROP CALCULATIONS CIRCUITS. MAXIMUM DISTANCE WITHOUT INCREASING CONDUCTOR SIZE. 1. NOTIFICATION A MAXIMUM 2. FIELD VERIFY 3. NAC CIRCUITS CURRENT ARE INSTALLED, FOR ALL 4. DO NOT EXCEED CEILING 22' -0" (264 ") TO 19' -0" (228 ") CEILING MOUNTED (SEE NOTE 4) SEE NOTE 3 SEE NOTE 3 SEE NOTE 5 10' -0" (120") 6' -8" (80 ") CEILING MOUNTED (SEE NOTE 2) 4'-g" (57 ") FACP FAAN II SEE NOTE 1 NOTES: BATTERY CALCULATIONS (BOSCH FPD -7024) NO. DATE DESCRIPTION STANDBY POWER IN ALARM ISSUED FOR PERMITS MODEL NUMBER DESCRIPTION QUANTITY CURRENT PER DEVICE (mA) TOTAL CURRENT (mA) 1 CURRENT PER DEVICE (mA) TOTAL CURRENT (mA) STANDBY BATTERIES (12 VOLT) CURRENT (mA) FPD -7024 FIRE ALARM CONTROL PANEL 1 200 200 I 380 380 D7039 MULTIPLEX EXPANSION MODULE 1 150 150 150 150 STANDBY CURRENT 438.50 FMR -7036 FIRE ALARM ANNUNCIATOR 1 80 80 100 100 HOURS 24 FMM- 7045 -D MANUAL PULL STATION 7 0.55 3.85 0.55 3.85 STANDBY mAH 10,524 D7050 SMOKE DETECTOR 1 0.50 0.50 0.56 0.56 ALARM CURRENT 806.56 D7052 INPUT MODULE 5 0.55 2.75 0.55 2.75 HOURS - 0.083 D7053 INPUT /OUTPUT MODULE 2 0.70 1.40 0.70 1.40 ALARM mAH 67 TOTAL mAH 10,591 WHEELOCK APPLIANCE CIRCUIT AVEX 1 0 0 168 168 TOTAL AH 10.6 PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 CONTINGENCY 20% I BATTERY TOTAL (AH) 12.7 I TOTAL 438.50 806.56 BATTERY PROVIDED (AH) 18 NOTES: LISTED FOR REQUIRED BATTERY CAPACITY. BATTERY CABINETS LISTED FOR FIRE ALARM USE. 1. PROVIDE BATTERY CHARGER 2. PROVIDE ANY REQUIRED BATTERY CALCULATIONS - WHEELOCK APS (PS -24 -8MP) NO. DATE DESCRIPTION STANDBY POWER 1 IN ALARM ISSUED FOR PERMITS MODEL NUMBER DESCRIPTION QUANTITY CURRENT PER CIRCUIT (mA) TOTAL CURRENT ' (mA) CURRENT PER CIRCUIT (mA) TOTAL CURRENT (mA) STANDBY BATTERIES (12 VOLT) CURRENT (mA) PS -24 -8MP AUX. POWER SUPPLY (APS) #1 1 60 60 100 100 WHEELOCK APPLIANCES CIRCUIT AV01 1 0 0 1,665 1,665 STANDBY CURRENT 60 WHEELOCKAPPLIANCES CIRCUIT AVO2 1 0 0 r 1,665 1,665 HOURS 24 WHEELOCKAPPLIANCES CIRCUIT AVO3 1 0 0 1,665 1,665 STANDBY mAH 1,440 WHEELOCK APPLIANCES CIRCUIT AVO4 1 0 0 1,272 1,272 ALARM CURRENT 6,367 HOURS 0.083 ALARM mAH 528 TOTAL mAH 1,968 TOTAL AH 2.0 PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 CONTINGENCY 20% I BATTERY TOTAL (AH) 2.4 I TOTAL 60 6,367 BATTERY PROVIDED (AH) 7 BATTERY CALCULATIONS - WHEELOCK APS (PS -24 -8MP) NO. DATE DESCRIPTION STANDBY POWER IN ALARM ISSUED FOR PERMITS MODEL NUMBER DESCRIPTION QUANTITY CURRENT PER CIRCUIT (mA) TOTAL CURRENT (mA) CURRENT PER CIRCUIT (mA) TOTAL CURRENT (mA) STANDBY BATTERIES (12 VOLT) CURRENT (mA) PS -24 -8MP AUX. POWER SUPPLY (APS) #2 1 60 60 100 100 WHEELOCKAPPLIANCES CIRCUIT AVO5 1 0 0 1,132 1,132 STANDBY CURRENT 60 WHEELOCKAPPLIANCES CIRCUIT AVO6 1 0 0 1,414 1,414 HOURS 24 WHEELOCK APPLIANCES SPARE 0 0 0 0 0 STANDBY mAH 1,440 WHEELOCK APPLIANCES SPARE 0 0 0 0 0 ALARM CURRENT 2,646 HOURS 0.083 ALARM mAH 220 TOTAL mAH 1,660 TOTAL AH 1.7 PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 CONTINGENCY 20% BATTERY TOTAL (AH) 2.0 TOTAL 60 2,646 BATTERY PROVIDED (AH) 7 I MAXIMUM 4' -0" (48 ") MINIMUM 3' -6" (42 ") FINISHED FLOOR 1. MEASURED TO THE OPERABLE PART OF THE PULL STATION. 2. LOCATE CEILING MOUNTED SMOKE DETECTORS FLUSH WITH THE CEILING, AS INDICATED IN NFPA 72. 3. MEASURED TO THE BOTTOM OF THE LENS. 4. LOCATE CEILING MOUNTED NOTIFICATION APPLIANCES ON THE BOTTOM OF THE BEAM OR JOIST. 5. SEE ELECTRICAL DRAWING E01. 6. MEASURED TO THE TOP OF THE BACKBOX. 1. CABLES SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2. THE ANNULAR SPACE BETWEEN CABLE/CABLE BUNDLE AND PERIPHERY OF OPENING SHALL BE LESS THAN 1 INCH. 3. MAXIMUM OF A 1 INCH DIAMETER CABLE BUNDLE PER FIRESTOP SYSTEM. 4. CAULK MATERIAL - MINIMUM 5/8 INCH THICKNESS OF FILL MATERIAL APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF THE WALL. MINIMUM 1/2 INCH DIAMETER BEAD OF CAULK APPLIED AT THE CABLENVALLBOARD INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. 5. CONSULT CURRENT U.L. FIRE RESISTANCE DIRECTORY FOR DETAILS. FIRE RATED GYPSUM WALLBOARD CABLE PENETRATION U.L. W -L -3149 NOT TO SCALE TYPICAL DEVICE MOUNTING HEIGHT DETAIL NOT TO SCALE 1 OR 2 HOUR RATED GYPSUM WALLBOARD ASSEMBLY NOTES: AIM MIL 3M FIRE BARRIER CP 25WB+ CAULK OR EQUAL CONDUIT 1. CONDUIT SHALL BE INSTALLED AT CENTER OF STUD CAVITY WIDTH AND SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2. CAULK FILL MATERIAL SHALL COMPLETELY FILL ANNULAR SPACE BETWEEN CONDUIT AND WALL; AND SHALL HAVE A 1/4 INCH DIAMETER BEAD OF CAULK APPLIED TO PERIMETER OF CONDUIT AT ITS EGRESS OF THE WALL. FOR CONDUIT 1 INCH DIAMETER AND SMALLER, THE ANNULAR SPACE SHALL BE LESS THAN 1 -1/2 INCHES . 3. MAXIMUM OF (1) CONDUIT PER FIRESTOP SYSTEM. 4. CONSULT CURRENT U.L. FIRE RESISTANCE DIRECTORY FOR DETAILS. FIRE RATED GYPSUM WALLBOARD CONDUIT PENETRATION U.L. W -L -1001 NOT TO SCALE NOTES: 1. FOR CEILING MOUNTED SMOKE DETECTORS AND OCCUPANT NOTIFICATION APPLIANCES IN AREAS WITH SUSPENDED CEILINGS. JUNCTION BOX MOUNTING DETAIL NOT TO SCALE IA 0 %P0 1 OR 2 HOUR RATED CONCRETE BLOCK WALL ASSEMBLY NOTES: 3M FIRE BARRIER CP 25WB+ CAULK OR EQUAL PACKING MATERIAL 1. CONDUIT SHALL BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. 2. THE ANNULAR SPACE BETWEEN CONDUIT AND PERIPHERY OF OPENING SHALL BE LESS THAN 1 -3/8 INCHES. 3. MAXIMUM OF (1) CONDUIT PER FIRESTOP SYSTEM. 4. PACKING MATERIAL - MINIMUM 4 INCH THICKNESS OF MINIMUM 8 PCF MINERAL WOOL BATT INSULATION SHALL BE FIRMLY PACKED INTO OPENING AS A PERMANENT FORM. 5. PACKING MATERIAL SHALL BE RECESSED FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK MATERIAL. 6. CAULK MATERIAL - MINIMUM 1/2 INCH THICKNESS OF FILL MATERIAL SHALL BE APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTH SURFACES OF THE WALL. 7. CONSULT CURRENT U.L. FIRE RESISTANCE DIRECTORY FOR DETAILS. FIRE RATED CONCRETE BLOCK WALL CONDUIT PENETRATION U.L. C -AJ -1045 NOT TO SCALE ViD1111,111111111'.1111, ll li r ihVoir REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 19 2010 City of Tukwila BUILDING DIVISION CODE CONSULTANTS, INC. RECEIVED MAR 112010 PERMIT CENTER I..UIN I K. UUL rk KtV ISIUIVS ' NO. DATE DESCRIPTION 03/09/10 ISSUED FOR PERMITS 03/09/10 ISSUED FOR BIDS PROTOTYPE UPDATES NO. DATE DESCRIPTION 0 12/14/09 2010 46K REV. 0 BID DATE: 03/09/10 PROJECT NO.: 090448.07.000 DRAWN BY: JLS CHECKED BY: DJB PROTOTYPE DESIGNATION: PROTOTYPE DATE: 03/08/10 FIRE PROTECTION •- ENGINEER OF RECO' I DAVID J. BURKHART, PE LICENSE NO. 0030980 Al 44( *N OF W4Syfv 91j, /® -4 Q r e� 0030980 ,, CODE CONSULTANTS, INC. O� ��C/ST6R�� ST. LOUIS, MO 63146-4136 �SSJONALV, � PHONE: 314-991-2633 CORPORATE CERTIFICATE OF AUTHORITY ! d N0.1604 � l( i�is DID C\A \ i D Sil C 'Zi> ig21 ES STORE SUPPORT CENTER ONE GEOFFREY WAY WAYNE, NJ 07470 THIS DRAWING IS THE EXCLUSIVE PROPERTY OF TOYS "R" US. THE INFORMATION SHOWN MAY NOT BE USED NOR THE DRAWINGS REPRODUCED WITHOUT PERMISSION OF TOYS "R" US. LOCATION T U KW WA I LA, DRAWING TITLE FIRE ALARM NOTES AND DETAILS SCALE AS INDICATED ISSUE DATE DECEMBER 14, 2009 SHEET NO. ,