Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0213 - WESTFIELD SOUTHCENTER MALL - FOOTLOCKER - HOUSE OF HOOPS
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. El-1 0-0213 Footlocker 1090 Southcenter Mall RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 19 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. FOOTLOCKER HOUSE OF HOOPS 1090 SOUTHCENTER MALL EL1O-0213 City ("Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 1090 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL10 -0213 Issue Date: 06/09/2010 Permit Expires On: 12/06/2010 Tenant: Name: FOOTLOCKER - HOUSE OF HOOPS Address: 1090 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KENT FAHEY Phone: 800 - 556 -8641 Address: 3019 HOLLINWELL DR , KATY TX Contractor: Name: SEA TAC ELECTRIC INC Phone: Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Expiration Date: 12/17/2011 DESCRIPTION OF WORK: INSTALL /ADD /RELOCATE FIXTURES (SALES COUNTER, LIGHTS, MONITOR). REUSE EXISTING ELECTRICAL SERVICE Value of Electrical: NRES: $5,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $223.13 National Electrical Code Edition: 2008 Date: CQ LA [t0 I hereby certify that I have read and xanu ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, whether specified herein or not. The granting of this permit does not pre e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ;s - e of wo I am authorized to sign and obtain this electrical permit. Signature: Print Name: 244 a/4 rd Date: C" 9. /e) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL10 -0213 Printed: 06 -09 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: PERMIT CONDITIONS 1090 SOUTHCENTER MALL TUKW FOOTLOCKER - HOUSE OF HOOPS Permit Number: Status: Applied Date: Issue Date: EL10 -0213 ISSUED 03/17/2010 06/09/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: o � / iq flyµ -F�df Date: ‘ / / doc: Cond -Elec ELI 0-0213 Printed: 06 -09 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://Www.ci.tukwila.wa.us • Electrical Permit No. E1-10— 0 t 3 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATIO Site Address: Tenant Name: King Co As ssor's Tax No.: ite NumbeC. Property Owners Name: Mailing Address: (t33 City Floor: New Tenant: ❑ Yes ❑..No State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: g t—kt = " ^ _* _ Day Telephone —SSA --c�lc��..l k Mailing Address: tet k IDC A,1 In1l.t. T�►L_ �" �'I �'�} �� City Late Zip E -Mail Address: A:Z1 L (LiA--k- -- -t (J09‘,1FaxNumber: 'Lek ELECTRICAL CONTRACTOR INFORMATION Company Name: .17),,r-- --rez) Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Valuation of Project (contractor's bid price): $ CITZ:rDer) Scope of Work (please provide detailed information): Will service be altered? ❑ Yes 1:1 No Adding more than 50 amps? ❑ Yes No Type of Use: Type of work: ❑ New 1:1 Addition ❑ Service Change l Remodel Tenant Improvement Low Voltage ❑ Generator ❑ Fire Alarm Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line \2010 Applications \I -2010 - Electrical Permit Application.doc bh Page 1 of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added /altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea Contact / Applicant Kent Fahey 800 - 556 -8641 Fax 281 -579 -2227 rtlpermits@yahoo.com PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: :.v1d.s, �t \. 04.e.1'� Print Name:st:JCt %� �y,�t'sJ Mailing Address: S.-SO \ S . � a �-\ - Date: G 5- t �i ..-e)1D Day Telephone: ti�i N u:A, qZV- --1 City State Zip IDate Application Accepted: Date Application Expires: a' ( 0 Staff lnitials: H: \Applications \Forms- Applications On Line \2010 Applications \I -2010 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0213 Address: 1090 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/17/2010 Applicant: FOOTLOCKER - HOUSE OF HOOPS Issue Date: Receipt No.: R10 -01016 Initials: User ID: JEM 1165 Payment Amount: $178.50 Payment Date: 06/09/2010 10:44 AM Balance: $0.00 Payee: SEA -TAC ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 9021 178.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 178.50 Total: $178.50 PAYMENT RECEIVED doc: Receiot -06 Printed: 06 -09 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0213 Address: 1090 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/17/2010 Applicant: FOOTLOCKER - HOUSE OF HOOPS Issue Date: Receipt No.: R10 -00471 Initials: WER User ID: 1655 Payment Amount: $44.63 Payment Date: 03/17/2010 09:39 AM Balance: $178.50 Payee: RETAIL PERMIT SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1068 44.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 44.63 Total: $44.63 PAYMENT RECEIVED doc: Receipt -06 Printed: 03 -17 -2010 INSPECTION RECORD Retain a copy with permit 6A0- 0113 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 1 _ , ,S a Typg of Inspection: 4 lo% Address: 10?0 !ate Date•Called: Special Instructions: Date Wanted: Or a m m. Requester: Phone No: NApproved per applicable codes. COMMENTS: Corrections required prior to approval" (Afirt, ` Date: 00 5 / 0 ❑ $60.00 REINSPEC ION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: .+?z T" q +ate • ° .6Y.y0 &sY 5 �i- �s.+..s. ■ 2006 Washington State Nonresidential Energy Code Compliance Form --"~-'� — — - Project Summary - 2006 Washington State Nonresidential Energy Code Compliance Forms' PRJ -SUM - - Revised July 2007 Project Info Project Address sooxHCENTER MALL Date 3/11/2010 633 SoUTHCENTER PKWY For Building Department Use TUKWILA, WA 98188 Applicant Name: FOOT LOCKER INC. - MARYANN VISICARO Applicant Address: 112 WEST 34TH STREET, NY, NY 10120 Applicant Phone: 212- 720 -4297 FILE COPY Permit No. ELltO23 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC MAR 2 2 2010 City of 'Tukwila BUILDING DIVISION RECEIVED NIeR 172010 ?ERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT -_ 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address SO THCENTER MALL Date 3/11/2010 633 SOUTHCENTER PKWY For Building Department Use TUKWILA, WA 98188 Applicant Name: FOOT LOCKER INC. - MARYANN VISICARO Applicant Address: 112 WEST 34TH STREET, NY, NY 10120 Applicant Phone: 212 -720 -4297 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition ✓ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting 66.0 & space use not changed. ,/ Less than 60% of the fixtures new, installed wattage not increased, Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area Sales Retail - General 1.50 6643.0 9964.5 Sales Retail - Display 3.00 554.0 1662.0 Sales Common Areas (Toilet) 0.80 66.0 52.8 Stock 4' Strip Flourescent 21 32.0 672.0 • " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 11679.3 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures .:: Watts/ Fixture Watts Proposed Sales HOH Track H2 - Display 56 20.0 1120.0 Sales HOH Pendant 8 42.0 336.0 Sales Ex'g Recessed Down -RD 14 42.0 588.0 Stock 4' Strip Flourescent 21 32.0 672.0 Stock 8' Strip Flourescent 19 64.0 1216.0 Toilet Recessed Light /Fan Combo 1 100.0 100.0 Office 2 x 2 Recessed Flourescent 1 120.0 120.0 Office 2 x 4 Recessed Flourescent 1 240.0 240.0 Fitting Room 2 x. 2 Recessed Flourescent 1 120.0 120.0 Sales 2 x 2 Recessed Flourescent 34 120.0 4080.0 Sales Existing Track Lights - Display 32 70.0 2240.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 10832.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form- Interior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector • or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5'7'" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments °, restaurants /bars° 1.3 Post office 1.1 Dormitory 1.0 Retail70, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia °, assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall °'4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other aj3propriate categories) v 1.8 Parking garages 0.2 Laundries -: 1.2 Lib 1.3 Plans Submitted for Common Areas Only Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and .offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. _ . - 2006. Washington State Nonresid- ential Energy Code Compliance Form-- Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms - Revised July 2007 Project Info Proj Addres: SOUTHCENTER MALL Date 3/11/2010 633 SOUTHCENTER PKWY For Building Department Use TUKWILA, WA 98188 Name: FOOT LOCKER INC. - MARYANN VISICARO Appl. Name 112 WEST 34TH STREET, NY, NY 10120 Appl. Phone 212 - 720 -4297 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option O Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/W ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations v — Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Tradable Provosed Lighting Wattage otal Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard,-,wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Proposed Watts may not exceed Allowed Watts for Category - Exterior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Form-- ~----'` 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS LTG -EXT - Revised July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft2 Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft2 Stairways 1.0 W /ft2 Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ftz Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft2 Street frontage for vehicle sales lots in addition to `open area" allowance 20 W /linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades I- C, 0.2 W /ft2 for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller'' machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W /ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft 2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft2 Drive -up windows at fast food restaurants 400W per drive- through Parking near 24-hour retail entrances 800 W per main entry -= - - - w- -- -2006 Washington State Nonresidential Ehergy`Code Compliance Form–,---- - , .�.�. Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address SODTHCEHTER MALL Date 3/11/2010 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft2 ** From Table 15 -1 based on exceptions listed in footnotes Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address SOUTHCENTER MALL IDate 3/11/2010 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) 1513.1 Local control /access Schedule with type, indicate locations 1513.2 Area controls Maximum limit per switch 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w/backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations • 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) 1514 (Max. watts 'Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) 1531 Interior Lighting Summary Form Completed and attahhed. Schedule with fixture types, lamps, ballasts, alts per fixture 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) I1540 (Transformers 'Indicate size and efficiency I I If "no" is circled for any question, provide explanation: 2006 Washington State Noriresidential Energ Code Com: Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms _ _ ._ Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, w ich control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are alowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). I'; 4ktE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0213 DATE: 03 -17 -10 PROJECT NAME: FOOTLOCKER - HOUSE OF HOOPS SITE ADDRESS: 1090 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART,.E/NTS: aisding Division VI 0 Public Works Fire Prevention Structural Planning Division Permit Coordinator A DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 03 -18 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions DUE DATE: 04 -15 -10 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Sea Tac Electric Inc 2538725553 7056 S 220Th St Kent Wa 98032 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601510212 Active SEATAEI077RW Electrical Contractor 12/16/1993 12/17/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATAEC131QCSea -Tac Electrical Contractors Electrical Contractor General Unused 11/3/1987 11/3/1995 Archived MASTER ELECTRICIAN INFORMATION License HARGRT'974CD Name Hargreaves, Tom Status Active Business Owner Information Name Role Effective Date Expiration Date Hargreaves, Tom Agent 12/17/1993 Bond Amount Hargreaves, Tom President 12/17/1993 798649C Bean, Eric Secretary 12/10/2008 Bean, Eric Treasurer 12/10/2008 MERCHANTS BONDING CO (MUTUAL) Jordan, Tom Vice President 01/01/2002 01/22/2009 Hargreaves, Katherine Secretary 12/17/1993 12/10/2008 Burks, Roy Vice President 12/17/1993 12/15/1995 1 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 DEVELOPERS SURETY & INDEM CO 798649C 12/16/2008 Until Cancelled $4,000.00 12/03/2008 5 MERCHANTS BONDING CO (MUTUAL) WA11373 12/16/2004 Until Cancelled 01/22/2009 $4,000.0012/17/2004 4 CUMBERLAND CAS & SURETY CO MB912300132 12/16/2001 Until Cancelled 12/16/2004 $4,000.0001/09/2002 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 12/16/1993 Until Released Bond $4,000.00 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type https: / /fortress.wa. gov /lni/bbip /Print.aspx 06/09/2010 153'-4 3/4' LEASE LINE DIMENSION 24'-0' 24'-0' -r- — — — — — — — — — — — -i I h-1 r — — — 0 cow (TYP. STOCKROOM) r- —T— T r- t-- m IT TIT —1 11 111 111 111 1 1 1 11 111 111 111 1 1 I 1 1 1 1 1 1 I IH 1- +H E I 1 I I 1 1 I I I 1 1 1 I I I 1 I I 1 1 I I I 1 I I 1 1 1 I 1-+-1 F+-I 1-+-1 F±-1 11 111 111 1 1 1 111 1 1 1 1 1 1 1 1 I 1 I 1 I I 1 1 1 I I I I 1 1 1 I I I I I I H I 1 1 I I I I I I 1-±-1 1 1 I 1 I I I 1 I (TYP. FL SALES AREA) 4B' -0' LEASE EXISTING STOCKROOM FOOT LOCKER AREA ELECTRICAL POWER PLAN SCALE: 3/16" = 1'-0" SYMBOL DESCRIPTION MOUNTING 4-IGT. TO CENTERLINE UNLESS OTI-IERUJISE NOTED SYMBOL DESCRIPTION MANUAL MOTO R STARTING SWITCH W/ PILOT LIGHT 48' APP. (TYP) DUPLEX RECEPTACLE, 3 WIRE GIRD. TYPE, 20A 18' APP. (TYP) TELEPHONE OUTLET IS' APP. (TYP) M:DUJP DUPLEX RECEPTACLE, WEATI-ERPROOF,20A 18' AP.F. (TYF') Gifi • GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 204 18' 4P.F. (TYP) QUADRAPLEX WALL RECEPTACLE, 204 18' APP. (TYP) 2 DATA OUTLET - DUPLEX CATEGORY 5 18' APP. (TYP) F.I. W/LIGI-IT 4 SWITCH AS REQUIRED SAFETY SWITCH AS REQUIRED PUSHBUTTON STATION 48' AFF. (TYP) MAGNETIC MOTOR STARTER AS REQUIRED LOW VOLTAGE BUZZER TRANSFORMER AS REQUIRED DOOR BUZZER 54' A.F.F. (TYP) COMBINATION STARTER/SAFETY SWITCH AS REQUIRED MOTOR OUTLET - !PHASE AS REQUIRED MOTOR OUTLET - 3 PHASE AS REQUIRED ELECTRICAL SYMBOLS SCHEDULE ALL SYMBOLS DO NOT NECESSARILY APPLY Plan review approval is subject to errors and ons. Approval of co - •en documents does not authorize the violation of any adopted or ordin Receipt of approved Field Copy .„, CI! , edged: Date: - ?- /0 City Of Ttikwila BUILDING DIVISION FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: 'TRICARICO® Tricarico Architecture and Design PC 500 Valley Road Wayne, NJ 07470 T (973) 692-0222 F (973) 692-0223 www.tricarico.com 0 2010 NICHOLAS J. TRICARICO 4306 SEAL: RE S ER; ARC CT NICHOLAS J. TRICARICO STATE OF WASHINGTON SEAL: REVISIONS NO. DESCRIPTION DATE 0 FIRST ISSUE 03/1 1 /1 0 ALL EXISTING F'OUJER DEVICES, EQUIPMENT, ETC. IN THE SPACE TO REMAIN AS IS. FLUSH MOUNT (1) 204 DUPLEX RECEPTACLE (IG. HOSPITAL GRADE) IN WALL OR CEILING ABOVE MONITOR. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS. RUN COAXIAL CABLE IN CONDUIT FROM EACH MONITOR LOCATION TO AIV RACK WITH 4' EXTRA CABLE COILED AT EACH END. ® RECEPTACLES AND COVES:PLATES SHALL BE FLUSH MINTED * 5'-3' APP. FOR CONNECTION OF ILLUMINATED CABINETS. CIRCUIT AS NDICATED. VERIFY LOCATION 4 QUANTITY OF RECEPTACLES MILLWORK S1-10P DRAWING& WIRE TO 20 AMP SPARE CIRCUIT AT EXISTING 120/20SV PANEL. CONTROLLED VIA SWITCH - SEE SWITC1415ANK DETAIL SHEET E2.0. ® BOUNDARY OF H014 SPACE. CD EXISTING ELECTRICAL SERVICE EQUIPMENT TO REMAIN. /IA THE EXISTING FIRE ALA REL RM SYSTEM TO BE USE AND OCATED. F REQUIRED, INCLUDE IN HIS v=/ BI D THE COST FOR A COMPLETE OPERATIONAL FIRE ALARM SYSTEM. TI415 SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED To RELOCATING EXISTING DEVICES, REPLACING DAMAGED DEVICES, AND ADDING ADDITIONAL DEVICES AS REQUIRED TO MEET CODE REQUIREMENTS. PREPARE AND SUBMIT A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WOW GC. TO WIRE BACK NEW HOI-1 A/V EQUIPMENT TO EXISTING MANAGERS DESK_ COORDINATE WITI-I A/1/ \-t VENDOR FOR ANY ADDITIONAL REQUIRED ELECTRICAL DEVICES, ETC. (1) NOT USED. NOT USED. NOT USED. 20AMP,I20V., ISOLATED GROUND/DEDICATED CIRCUIT, RECEPTACLE (HUBBELL 0IG-5362) MOUNTED AT 18' AFF. DO NOT INSTALL WITH ANY OTHER CIRCUITS RUN 2 1'12 T14�4 AND I •12 ISOLATED GRID. IN SINGLE 3/4' CONDUIT !BACK TO PANEL FOR COMPUTER TERINAL I' CONDUITS RUN UNDER FLOOR. CORE AND PATCH FLOOR AS REQUIRED. COORDINATE FLOOR CORING WITI4 LANDLORD PRIOR TO STARTING WORK_ TELEPHONE OUTLET (VOICE). USE 4' SQUARE JUNCTION BOX WITH PHONE JACK AND COVERPLATE. RUN 1' EMPTY CONDUIT WITH PULL WIRE INTO WALL, UP WALL TO STRUCTURE ABOVE, BACK TO TELEPHONE BOARD. .11n1AgrQEIF.LgE1:g2NrjjtgFjEraUIEEtlaITA- (1) LINE REQUIRED At IBACKLURAP FOR I-141,05T (1) DEDICATED PI-IONE LINE AT CASHWRAP FOR CREDIT VERIFICATION, EQUIPMENT, MODEM, ETC. REFER TO CABLE BLOCK DIAGRAM ON 51-EET E4.0. 20AMP, 120V., DUPLEX RECEPTACLE AT CASH WRAF' COUNTER FOR UTILITY POWER LOCATE RECEPTACLES AT CASH WRAP COUNTER AS DIRECTED SY OWNER RUN 2 *12 TN AND 2 $12 GRD IN I' CONDUIT UNDER FLOOR SLAB TO WALL RUN UP WALL TO JUNCTION SOX AND CONNECT TO CIRCUIT INDICATED. REFER TO CABLE BLOCK DIAGRAM ON SHEET E4.0. IF NOT EXISTING, INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN!, INCLUDING EDWARDS 411136C-13 19.151-4 BUTTON AT REAR DOOR, MTD +4S'AP.F. (MAX.) 4590 'TRANSFORMER, 1125 BUZZER AS INDICATED. EXISTING RECEPTACLES TWAT INTERFERE WITH 1-101-1 LAYOUT TO BE REMOVED. G.C. TO PROTECT EXISTING THERMOSTAT DURING CONSTRUCTION MP TO RE-LOCATED AS SHOWNL VERIFY IN FIELD FOR EXACT LOCATION. G.C. TO PROTECT EXISTING TI-EWIOSTAT puRm CONSTRUCTION, THEM-IOSTAT TO REMAN AT EXISTING LOCATION. WIRE BACK TO EXISTING 20 AMP CIRCUIT FOR CASHUJRAP GENERAL POWER AT EXISTING 120/208V PANEL. WIRE !BACK TO EXISTING TELEPHONE BOARD. WIRE BACK TO EXISTING 20 AMP CIRCUIT FOR T.V. MONITORS AT EXISTING 120/208V PANEL. WIRE TO 20 Amp SPARE CIRCUIT FOR I.V. MONITORS AT EXISTING 120/2081/ PANEL. WIRE BACK TO EXISTING (4) DEDICATED 20 AMP SPARE CIRCUITS WITH ISOLATED GROUND LOCK-ON BREAKER AT EXISTING 120/208V PANEL 4 ISOLATED GROUND CIRCUIT CONDUIT UTILITY POWER CONDUIT I. REFER TO MECI-IANICAL PLAN FOR LOCATION OF MECI-IANICAL EQUIPMENT. FIELD VERIFY' EXACT LOCATIONS. 2. PROVIDE AND INSTALL AT PANEL 'A A TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL RECEPTACLES AND SWITCH PLATES IN SALES AND NON-SALES AREAS TO MATCH WALL OR CEILING FIN154-1 UNLESS DIRECTED OTI-ERUJISE. TYPICAL MOUNTING 1-EIGHT IS 18' AFF. EXCEPT AT COUNTERS OR F DIRECTED OTHERUJISE. 4. ALL CONDUITS SHALL BE CONCEALED N WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FNISHED WALL UNLESS OTHERWISE NOTED. 5. ALL WOW SHALL E3E IN STRICT ACCORDANCE WITI4 NATIONAL ELECTRIC CODE, ALL LOCAL CODES, ORDINANCES AND LANDLORD'S TENANT DESIGN CRITERIA. tot'or without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ! and may ims!uda additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC (F). Typ nrmint IIT STI IR-I IP a rASH\ARAP . • 111■•• ■••■ • le,Z7.„, ••••0,1 'AV • • l• •• • GFNFRAI pnwpR NoTES DESIGN DRAUJINK.28 ARE SCHEMATIC. VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTIN G CONDITION& THE CONTRACTOR SHALL CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OP THE DESIGN AND INCLUDE N 1-118 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE ET T44E ARCI4ITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL. CODES AND ORDINANCES AND SHALL INCLUDE N THEIR SIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. RECEIVED MAR 17 2010 PERMIT CENTER Li()--- 0213 POWER CODED NOTES ENLARGED TV MONITOR DETAIL FIELD VERIFY ALL CONDITIONS PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 SHEET TITLE ELECTRICAL POWER PLAN El .0 SHEET NO. DATE: 03/11/10 SCALE: AS NOTED GROSS AREA: 7180 SQ. FT. FL SALES AREA: 2,694 SQ. FT. HOH SALES AREA: 1,148 SQ. FT. PROJECT # : 100164 DRAWN BY: YW ALL EXISTING F'OUJER DEVICES, EQUIPMENT, ETC. IN THE SPACE TO REMAIN AS IS. FLUSH MOUNT (1) 204 DUPLEX RECEPTACLE (IG. HOSPITAL GRADE) IN WALL OR CEILING ABOVE MONITOR. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS. RUN COAXIAL CABLE IN CONDUIT FROM EACH MONITOR LOCATION TO AIV RACK WITH 4' EXTRA CABLE COILED AT EACH END. ® RECEPTACLES AND COVES:PLATES SHALL BE FLUSH MINTED * 5'-3' APP. FOR CONNECTION OF ILLUMINATED CABINETS. CIRCUIT AS NDICATED. VERIFY LOCATION 4 QUANTITY OF RECEPTACLES MILLWORK S1-10P DRAWING& WIRE TO 20 AMP SPARE CIRCUIT AT EXISTING 120/20SV PANEL. CONTROLLED VIA SWITCH - SEE SWITC1415ANK DETAIL SHEET E2.0. ® BOUNDARY OF H014 SPACE. CD EXISTING ELECTRICAL SERVICE EQUIPMENT TO REMAIN. /IA THE EXISTING FIRE ALA REL RM SYSTEM TO BE USE AND OCATED. F REQUIRED, INCLUDE IN HIS v=/ BI D THE COST FOR A COMPLETE OPERATIONAL FIRE ALARM SYSTEM. TI415 SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED To RELOCATING EXISTING DEVICES, REPLACING DAMAGED DEVICES, AND ADDING ADDITIONAL DEVICES AS REQUIRED TO MEET CODE REQUIREMENTS. PREPARE AND SUBMIT A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WOW GC. TO WIRE BACK NEW HOI-1 A/V EQUIPMENT TO EXISTING MANAGERS DESK_ COORDINATE WITI-I A/1/ \-t VENDOR FOR ANY ADDITIONAL REQUIRED ELECTRICAL DEVICES, ETC. (1) NOT USED. NOT USED. NOT USED. 20AMP,I20V., ISOLATED GROUND/DEDICATED CIRCUIT, RECEPTACLE (HUBBELL 0IG-5362) MOUNTED AT 18' AFF. DO NOT INSTALL WITH ANY OTHER CIRCUITS RUN 2 1'12 T14�4 AND I •12 ISOLATED GRID. IN SINGLE 3/4' CONDUIT !BACK TO PANEL FOR COMPUTER TERINAL I' CONDUITS RUN UNDER FLOOR. CORE AND PATCH FLOOR AS REQUIRED. COORDINATE FLOOR CORING WITI4 LANDLORD PRIOR TO STARTING WORK_ TELEPHONE OUTLET (VOICE). USE 4' SQUARE JUNCTION BOX WITH PHONE JACK AND COVERPLATE. RUN 1' EMPTY CONDUIT WITH PULL WIRE INTO WALL, UP WALL TO STRUCTURE ABOVE, BACK TO TELEPHONE BOARD. .11n1AgrQEIF.LgE1:g2NrjjtgFjEraUIEEtlaITA- (1) LINE REQUIRED At IBACKLURAP FOR I-141,05T (1) DEDICATED PI-IONE LINE AT CASHWRAP FOR CREDIT VERIFICATION, EQUIPMENT, MODEM, ETC. REFER TO CABLE BLOCK DIAGRAM ON 51-EET E4.0. 20AMP, 120V., DUPLEX RECEPTACLE AT CASH WRAF' COUNTER FOR UTILITY POWER LOCATE RECEPTACLES AT CASH WRAP COUNTER AS DIRECTED SY OWNER RUN 2 *12 TN AND 2 $12 GRD IN I' CONDUIT UNDER FLOOR SLAB TO WALL RUN UP WALL TO JUNCTION SOX AND CONNECT TO CIRCUIT INDICATED. REFER TO CABLE BLOCK DIAGRAM ON SHEET E4.0. IF NOT EXISTING, INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN!, INCLUDING EDWARDS 411136C-13 19.151-4 BUTTON AT REAR DOOR, MTD +4S'AP.F. (MAX.) 4590 'TRANSFORMER, 1125 BUZZER AS INDICATED. EXISTING RECEPTACLES TWAT INTERFERE WITH 1-101-1 LAYOUT TO BE REMOVED. G.C. TO PROTECT EXISTING THERMOSTAT DURING CONSTRUCTION MP TO RE-LOCATED AS SHOWNL VERIFY IN FIELD FOR EXACT LOCATION. G.C. TO PROTECT EXISTING TI-EWIOSTAT puRm CONSTRUCTION, THEM-IOSTAT TO REMAN AT EXISTING LOCATION. WIRE BACK TO EXISTING 20 AMP CIRCUIT FOR CASHUJRAP GENERAL POWER AT EXISTING 120/208V PANEL. WIRE !BACK TO EXISTING TELEPHONE BOARD. WIRE BACK TO EXISTING 20 AMP CIRCUIT FOR T.V. MONITORS AT EXISTING 120/208V PANEL. WIRE TO 20 Amp SPARE CIRCUIT FOR I.V. MONITORS AT EXISTING 120/2081/ PANEL. WIRE BACK TO EXISTING (4) DEDICATED 20 AMP SPARE CIRCUITS WITH ISOLATED GROUND LOCK-ON BREAKER AT EXISTING 120/208V PANEL 4 ISOLATED GROUND CIRCUIT CONDUIT UTILITY POWER CONDUIT I. REFER TO MECI-IANICAL PLAN FOR LOCATION OF MECI-IANICAL EQUIPMENT. FIELD VERIFY' EXACT LOCATIONS. 2. PROVIDE AND INSTALL AT PANEL 'A A TYPED PANEL DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL RECEPTACLES AND SWITCH PLATES IN SALES AND NON-SALES AREAS TO MATCH WALL OR CEILING FIN154-1 UNLESS DIRECTED OTI-ERUJISE. TYPICAL MOUNTING 1-EIGHT IS 18' AFF. EXCEPT AT COUNTERS OR F DIRECTED OTHERUJISE. 4. ALL CONDUITS SHALL BE CONCEALED N WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FNISHED WALL UNLESS OTHERWISE NOTED. 5. ALL WOW SHALL E3E IN STRICT ACCORDANCE WITI4 NATIONAL ELECTRIC CODE, ALL LOCAL CODES, ORDINANCES AND LANDLORD'S TENANT DESIGN CRITERIA. tot'or without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal ! and may ims!uda additional plan review fees. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC (F). Typ nrmint IIT STI IR-I IP a rASH\ARAP . • 111■•• ■••■ • le,Z7.„, ••••0,1 'AV • • l• •• • GFNFRAI pnwpR NoTES DESIGN DRAUJINK.28 ARE SCHEMATIC. VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTIN G CONDITION& THE CONTRACTOR SHALL CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OP THE DESIGN AND INCLUDE N 1-118 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE ET T44E ARCI4ITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL. CODES AND ORDINANCES AND SHALL INCLUDE N THEIR SIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. RECEIVED MAR 17 2010 PERMIT CENTER Li()--- 0213 POWER CODED NOTES ENLARGED TV MONITOR DETAIL FIELD VERIFY ALL CONDITIONS PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 SHEET TITLE ELECTRICAL POWER PLAN El .0 SHEET NO. U l53' -4 3/4' LEASE LINE DIMENSION 24' -O• 24' -O• 24' -0• 24' -O' --- Lam- - - -- FI (E) FI -4(E) ---- -I- - - - -_L Fl (E) I-4(E) J O© IFt (Fa r---- -r---- -r--- -T - - -- - -- FI (E) FI -4(E) sum ■am UMIN MIN — — - T----- I- - - - --I - -- i J IFI (E) i IFl (E) 1 I FI-4(E) I i I L - - -_L. — _l__J FI -4(E) FI -4(E) MOM ■EM MIN MUM FI -4(E) FI -4(E) FI -4(E) UZI ERE • L---- L - -- I FI -4(E) FI (E) OD FI -4(E) i I I I !- -L_ _J- Z1_ I- 7_ =_TZ ..GTE —C Z --1 —fl.= - _I- T - --G-r-. =-7=-7. --I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1-±-1 I- I H I-±H 1-±-I I-±H I-±-I I-±-I I-+-1 +-1 I I I 1 1 1 1 1 1 1 I I 1 I I 1 1 I 1 1 I 11 I 1 I I I I 1 1 11FI R ) 1 1 I I 1 1 II 1 1 1 IFI (Fa 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 -I I- -1- -I 1- 1 -1 I- -1- -1 1- -F- -1 I- + -1 1- -I- -1 1-+ - 1-+ -1 +-I 1-+ -1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I 1 I I I I I I I I I 1 I I I I I II I 1 4/1 1 1 I h-i 1 1 r - - - --I (E) 1 I 1 1 I I I I 1 1- f 1 I I 1 1 1 1 1 1 1 1 I I I I 1 I 1 I 1 1 1 1 1 I I I I I I I I I.I I I 1 1-+-1 I- -I- -I 1-"+-1 f- H 1 I 1 I I I 1 I 1 I 1 1 1 1 1 1 1 IFf(E)1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I t i l l 1 I- -F- -1 F + -1 1-+ -1 I- -f- -1 1- - 1I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 I I I 1 i an EMI M■M FI (E) FI -4(E) FI -4(E) FI -4(E) EXISTING STOCKROOM NO NEW WORK HOUSE OF HOOPS AREA FOOT LOCKER AREA NOTE: G.C. TO VERIFY LOCATIONS OF ALL EXISTING EMERGENCY AND NIGHT LIGHT FIXTURES. G.G. To VERIFY ALL EMERGENCY AND NIGHT LIGHTS ARE OPERATIONAL, REPAIR AND /OR REPLACE LAMPS AND PACKS AS REQUIRED. COORDINATE ANY REQUIRED WORK WITH FOOTLOCKER C.M. ELECTRICAL LIGHTING PLAN FL LIGHT FIXTURE SCHEDULE • WASH & RE -LAMP ALL EX'G TO REMAIN LIGHT FIXTURES IN SALES AREA. CEILING FIXTURE SCHEDULE LIGHTING GENERAL NOTES LIGHTING PLAN CODED NOTES SCALE: 3/16" = 1 ' -0" TYPE SYMBOL NEW REMOVED TOTAL QTY. LAMP /DESCRIPTION TYPE SYMBOL MANUFACTURER DESCRIPTION (E) Fl 0 19 MM1328TOTEL5 - 8' - (2) 321U T8 LAMP TANDEM FLUORESCENT STRIP RE -LAMP ONLY AS REQUIRED SW JBL 5J -1: SUB WOOFER (BLACK FINISH - 14O14 AREA) (E) F1 -4 0 0 21 MM132OCTEL512 - 4' - (1) 32W T8 LAMP FLUORESCENT STRIP RE -LAMP ONLY 45 REQUIRED SP JBL SJ -2: SPEAKER/ SOUND SHALL NOT BE HEARD FROM 15' OR LESS FROM LEASE LINE. (SLACK FINISH - 1 -401 -I AREA) (E) F2 0 14 36. 54E340- 5IAX -9 -EL5 RECESSED 2'x2' FLUORESCENT FIXTURE W/ (3) F408X5PX35 40W BIAX LAMP* U 42' LCD MONITOR (E) F4 ■•■■■■ ■■■■■■ 0 0 RECESSED 2'x4' FLUORESCENT FIXTURE. VERIFY LAMP TYPE IN FIELD RE -LAMP ONLY AS REQUIRED BANNER TRACK SYSTEM (E) O 0 0 14 RECESSED COMPACT FLUORESCENT DOWNLIGHT VERIFY LAMP TYPE IN FIELD` 0 RETURN AIR GRILLE OR DUCT, SEE MI.0 FOR MORE INFO. (E) C'1 0 b 32 CON -TECH CTL"f01lU J) -5 W/ 233b6 PHILIPS MHC'10/U/MP /3K/ALTO LAMP* (10 WATT, ED11 METAL HALIDE) SUPPLY AIR DIFFUSER, SEE MI.0 FOR MORE INFO. TF EXISTING JUNO *TSWH (8' LTH) CHANNEL *161111-1 (b' LTH) TRACK 41-411.11-1 (4' LTH) *T2WH (2' LTH) SPRING LOADED 47ACHMENT MOUNT DIRECTLY TO LAY -IN CEILING 0 EXISTING SPRINKLER HEAD EXISTING SPRINKLER HEAD TO BE RELOCATED, AS REQUIRED. V.IF. (E) 0 0 EXISTING FAN /LIGHT COMBINATION FIXTURE (E) 0 7 EXISTING EXIT LIGHT W/ BATTERY PACK (E) 0 EXISTING COMBINATION EXIT LIGHT WITH TWO SIDE- MOUNTED LIGHTING HEADS W/ BATTERY PACK (E) 0 8 EXISTING SURFACE MOUNTED EMERGENCY LIGHT (E) = EXISTING LIGHT TO REMAIN - VERIFY EXIST NG QUANTITIES N.. = DENOTES NIGHT LIGHT (R) = EXISTING LIGHT TO BE RELOCATED - VERIFY EXISTING QUANTITIES EM = DENOTES EMERGENCY LIGHT I. THE CONTRACTOR FOR T1-415 WORK 15 REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND 15 RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OP ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK IT 15 THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF SID DOCUMENTS. 2. EXISTING 14VAC DIFFUSERS AND RETURN GRILLES TO REMAIN. G.C. TO CLEAN AS REQUIRED. 3_ SPRINKLER SYSTEM TO REMAIN. 4. G.C. TO REPLACE ALL LAMPS IN SALES AREA, VERIFY LAMP TYPE IN FIELD. 5. G.C. TO REPLACE ANY /ALL DEAD LAMPS IN. STOCK AREA AS REQUIRED AND REPAIR ANY FIXTURES WITH DEAD BALLASTS. COORDINATE ANY REQUIRED WORK WITH FL CM. b. G.C. TO VERIFY LOCATIONS OP ALL EXISTING EMERGENCY AND NIGHT LIGHT FIXTURES. G.C. TO VERIFY ALL EMERGENCY AND NIGHT LIGHTS ARE OPERATIONAL, REPAIR AND /OR REPLACE LAMPS AND PACKS AS REQUIRED. COORDINATE ANY REQUIRED WORK WITH FOOTLOCKER G.M. T. THE POSITION OF THE TRACK 15 TYPICALLY SET OUT FROM PERIMETER WALL AS INDICATED. CONTRACTOR TO POSITION TRACK LIGHTS TOWARD MERCHANDISE DISPLAYS ON PERIMETER AND IN SHOW WINDOWS. HOH LIGHT FIXTURE SCHEDULE NOTE: ALL HOH LIGHT FIXTURES ARE NEW FIELD VERIFY ALL CONDITIONS TYPE SYMBOL QTY. MANUFACTURER DESCRIPTION LAMP Hl L5I INDUSTRIES CITSM -42 -CFL - UE- G5K- A18EN -LD596 SURFACE MOUNT, FINISH: BRUSHED ALUMINUM W /SLACK NECK 42W CFL 142 56 AMERLUX CYLT- 20 -MM- CDM -TM -MINI MASTER COLOR -E- 120 -CL SLACK TEXTURE. PHILIPS 20W CDM -tM MINI MASTERCOLOR F9 SELUX MlRI- lT8- OD -RC- 004 -WH- 120 -FW: FLUORESCENT STRIP W/ CONTINUOUS FLANGE, ROTATING CROSSBAR MOUNTING (1) F032/T5 FLUORESCENT LAMP F10 L IGHTOLIER 8091DCCDW- 1 1425U: RECESSED T DIAMETER CFL LENSED DOWNLIGHT (1) OSRAM SYLVANIA CF42DT/E /IN /835/ECO TF -P CON -TECH CHANNEL TRACK *LT -8 -5 (8' LENGTH) *LT -b -B (b' LENGTH) *LT -4 -5 (4' LENGTH) *LT -2 -5 (2' LENGTH) T -BAR ATTACHMENT PENDANT MOUNTED TRACK E3 HIGHLITES I-1L -W (WHITE FINISH) SURFACE MOUNTED EMERGENCY LIGI.1T MOUNTED ON THE COLUMN FACING: THE 14014 SALES AREA, SEE RCP. HOW-FLUIDS DCI 8' FOOTWEAR WALL FIXTURE (I) CUSTOM 8' T8 LAMP A 128 WATTS 4 (4) CUSTOM 8' T5 LAMPS e 56 WATTS. TOTAL WATTS PER FIXTURE = 298 IUATT5. REFER TO E1.0 FOR MORE INFO, HOW -APB DCI 8' APPAREL WALL FIXTURE (I) CUSTOM 8' T8 LAMP 6 128 WATTS. TOTAL WATTS PER FIXTURE = 128 WATTS. REFER TO E1.0 FOR MORE INFO. HON -AP6 2 DCI b' APPAREL WALL FIXTURE (I) CUSTOM b' T8 LAMP 6 100 WATTS. TOTAL WATTS PER FIXTURE : 100 WATTS. REFER TO E1.0 FOR MORE INFO. 1404 -AP4 2 DCI 4' APPAREL WALL FIXTURE (1) 3' T8 LAMP 9 50 WATTS. TOTAL WATTS PER FIXTURE = 50 WATTS. REFER TO E1.0 FOR MORE INFO. 10H-PK DCI 8' FOOTWEAR DISPLAY FIXTURE (1) CUSTOM 8' TS LAMP * 128 WATTS. TOTAL WATTS PER FIXTURE = 128 WATTS. REFER TO E1.0 FOR MORE INFO. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO !BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO }BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS SID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL SE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL WAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR 5ID5 THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 1 EXISTING LIGHTING 51-1OWN AS (E) TO REMAIN ON THEIR ORIGINAL EXISTING CIRCUITS. RE- CIRCUIT EXISTING LIGHTS RE- CONFIGURE SWITCHING FROM REMOVED 2' X 2' LIGHTS. EXISTING EMERGENCY LIGHTING TO REMAIN. 0 BOUNDARY FOR 1-401-4 SPACE. 03 EXISTING MASTER LIGHTING SWITCH BANK WITH NEW LIGHTING SWITCHES FOR HOH SPACE. SEE SWITCHBANK DETAIL THIS SHEET. G.C. TO VERIFY EXISTING EMERGENCY LIGHTING IN EXISTING STOCK AREA 4 SERVICE CORRIDOR 4 SALES AREA. G.C. TO PROVIDE NEW AS NOTED, TO BE MOUNTED AS PER LIGHT SCHEDULE. ONEW 1401 -I LIGHT FIXTURES 4 TRACK HOMERUN THROUGH A b POLE CONTACTOR CONTROLLED SY SWITCH 'd'. CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. WIRE TO (2) 20 AMP SPARE CIRCUIT AT EXISTING 120/208V PANEL. ONEW HOW PENDANT LIGHTING. HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED SY SWITCH 'e'. CONTACTOR SHALL SE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH SANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. WIRE TO 20 AMP SPARE CIRCUIT AT EXISTING 120/208V PANEL. HOMERUN THROUGH A 4 -POLE CONTACTOR CONTROLLED BY SWITCH 'f'. CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH SANK DETAIL ON TI-4I6 SHEET AND 'POWER RISER' ON SHEET E3.0. 8 HOMERUN THROUGH AN (EXIST) b -POLE CONTACTOR CONTROLLED BY (EXIST) SWITCH 'b'. CONTACTOR TO BE WALL MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON T1-416 SHEET AND 'POWER RISER' ON SHEET E3.0. 9 HOMERUN THROUGH AN (EXIST) 6-POLE CONTACTOR CONTROLLED BY (EXIST) SWITCH 'c'. CONTACTOR TO BE WALL MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. 10 FURNISH AND INSTALL ADDITIONAL / NEW CONDUIT AND PULL WIRE TO ALL NEW 4 EXISTING A/V LOCATIONS AS REQUIRED A/V VENDOR CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER REPRESENTATIVE PRIOR TO BID. SEE DETAIL I/E1.0. 11 RELOCATED TRACK AND TRACK HEADS TO REMAIN, AND TO BE RE -WIRED SACK TO EXISTING CIRCUIT, AS REQUIRED. HOMERUN THROUGH AN EXISTING CONTACTOR CONTACTOR SHALL SE WALL MOUNTED ADJACENT TO LIGHTING PANEL. SEE SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER ON SHEET E3.0.) 12 EXISTING TRACK AND TRACK HEADS TO REMAIN, AND TO BE RE -WIRED BACK TO EXISTING CIRCUIT, AS REQUIRED. HOMERUN THROUGH AN EXISTING CONTACTOR CONTACTOR SHALL BE WALL MOUNTED ADJACENT TO LIGHTING PANEL. SEE SWITCH SANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0.) (.1- 3 EXISTING TRACK TO REMAIN, AND TO SE RE- WIRED SACK THROUGH EXISTING CONTACTOR CONTROLS BY EXISTING TIME CLOCK, AS REQUIRED. TRACK TO RECEIVE RELOCATED TRACK HEADS, NOT UTILIZED IN NEW LIGHTING LAYOUT. HOMERUN THROUGH AN EXISTING CONTACTOR VIA TIME CLOCK CONTACTOR SHALL BE WALL MOUNTED ADJACENT TO LIGHTING PANEL. SEE SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0.) 14 NOT USED. 15 EXISTING CEILING COMPONENTS, I.e. DIFFUSERS, SPRINKLER HEADS, ETC. TO REMAIN, TYP. G.C. TO CLEAN DIFFUSERS 4 REPAIR/REPLACE ANY DAMAGE FOUND AS REQ'D (COORDINATE WITH FL PROJECT CN.). ® CONNECT TO EXISTING EMERGENCY LIGHTING CIRCUIT AT EXISTING 120/208V PANEL. MASTER LIGHTING SWITCH BANK O (EXIST) Maw- wig (NEW) SALES SALES SALES STOCK/ NON -SALES SALES NEW SWITCH SALES NEW SWITCH SALES NEW SWITCH REVIEWED FOR COMPLIANCF WITH NFPA 70 - NEC MAR 222010 City of Tukwila BUILDING DIVISION FLUOR LIGHT$ FLUOR LIGHTS 'b' TRACK LIGI -It$ Id, FLUOR. LIGI -ITS NEW DISPLAY TRACK LTG FOR HOH -NEW TASK PENDANT LTS FOR HOH NEW CABINET LTS FOR HOW .d. is, +48" A.P.F RECEIVED MAR 17 2010 PERMIT CENTER FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: TRICARICO Tricarico Architecture and Design PC 500 Valley Road Wayne, NJ 07470 T (973) 692 -0222 F (973) 692 -0223 www.tricarico.com © 2010 NICHOLAS J. TRICARICO SEAL: -4306 - STEREO 1 Ch' T NICHOLAS J. TPIC.'IRCO STATE OF WASHINGTON SEAL: REVISIONS NO. DESCRIPTION DATE 0 FIRST ISSUE 03/11 /10 PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO. 701 0 SHEET TITLE ELECTRICAL LIGHTING PLAN N� E2.0 SHEET NO. DATE: 03/11/10 SCALE: AS NOTED GROSS AREA: 7180 SQ. FT. FL SALES AREA: 2,694 SQ. _ FT. HOH SALES AREA: 1,148 SQ. FT. PROJECT # : 100164 DRAWN BY: YW PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO. 701 0 SHEET TITLE ELECTRICAL LIGHTING PLAN N� E2.0 SHEET NO. SECONDARY REGISTER PRIMARY REGISTER CASH WRAP MANAGER'S DESK DSL Line Phone Line Store Demarc 25 Pair 66 Block 111= 1 • To Cash Wrap • • • • To Back Office • • • • • • CAT 3 Cable • • 2-4 Ter 2010 (Pler1,7.1,7n) 20100004BWH W1000 • • (107078388) • • • • • • • • • • • • • • • • • • 1111■1 41■111■1 1111 zsa Co 4). Co 03 Ox la° s'zi• CO CV "1-- 10 CO t's 03 IV CO 4). Back o3 * CD I 1 1 1 Co Surface-Mount Box M104SMB (4 Port) MI 04SMB-A-246 (107952442) Office 3 CO -•4 01 Phone DDSL 2 IA 0 4,1 V Co NI 0) cry 0 I I 1 10 CO 6- CO 4 +A. CO 4. o'D Cv LCo Surface-Mount Box M104SMB (4 Port) M104SMB -A-246 (107952442) Cash Wrap CABLE BLOCK WIRING DIAGRAM PHON VOICE LINE 1 (CASH WRAP 4 BACK OFFICE) DSL ONLY (CASH WRAP ONLY CP LUFRNG D ORANGE PAIR BROWN PAIR —K) U.) BLUE PAIR Gat 3 Jock MISH-H-2467 (101521121) GREEN PAIR Surfoc,e-Mount Box V10451\1'3 (4 Fort) •4104SME3-A-246 (101(452442) Al FUTURE VOICE LINE 2 (CASI-I WRAF' 4 BACK OFFICE) OCK WEIRING D 25 Fair SS Bloc< Goole to Gosh Aro DSL Phone sowimissamsCwom 1111111=1111111111111111■1 1 111111111•111111II Biall=111111111■11 1111111111•1111111111111111111111 •11111111111111111111111111 .1■=1101 11141111111■1111111111111 111111111111111111111■111111 1111111111111111111111111111M111111111 1■•=111111 __1 111111111•111111111111■11111111 111111111•111111111■ 4111111M1111111111• 41.11111111111■1111111 111•11111■1 0 NIRINS MUST BE GLEAN TO HOMERUN Goole to Bloc< Office NITH OUT ANY GR1MF'INS AND MUST NOT HAVE ANY ADDITION CONNECTIONS. WIRING DETAIL SECONDARY REGISTER WELL (2) (4684) 3° GROMMET HOLE (TYP.) -1 I SECONDARY 1REGISTER 1 WELL (2) (4654) *NOTE: VERIFY EXACT REQUIREMENTS WITH OWNER PRIOR TO INSTALLATION • 3° GROMMET HOLE (TYP.) CONTRACTOR TO FURN. AND INSTALL ONE DEDICATED CIRCUIT WITH ISOLATED GROUND (SEPARATE I-40T, NEUTRAL, AND GROUND 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET UNDER EACH WELL, 2 14UBBEL I.G.*5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL !BOARD. PRIM RY RE TER ELL (1) (4684) ---J SECONDARY REGISTER WELL (4) (4684) 3' GROMMET HOLE (TYP.) 0 0 0 0 CONTRACTOR TO FURN. AND INSTALL ONE DEDICATED CIRCUIT WITH ISOLATED GROUND (SEPARATE 140T, NEUTRAL, AND GROUND 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET UNDER EACH WELL, 2 141155EL I.G.*5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL 50ARD. CONTRACTOR TO FURN. AND INST. ONE DEDICATED DUPLEX OUTLET, WIRED TO PANEL BOARD. CONTRACTOR TO FURN. AND INSTALL ONE DEDICATED CIRCUIT WITH ISOLATED GROUND (SEPARATE HOT, NEUTRAL, AND GROUND 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET UNDER EACH WELL, 2 HUIBBEL I.G.*5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL 50ARD. PHONE OUTLET (SEE WIRING DETAIL 5 FOR PIN OUT) PHONE OUTLET (SEE WIRING DETAIL 5 FOR PIN co.) *NOTE: VERIFY EXACT REQUIREMENTS WITH OWNER PRIOR TO INSTALLATION CONTRACTOR TO FURN. AND INST. ONE DEDICATED DUPLEX OUTLET, WIRED TO PANEL BOARD. 1. FOR DEDICATED ELECTRICAL OUTLETS 2. FOR GENERAL ELECTRICAL POWER 3. SPARE 4. FOR TELEPHONE CA5LE CONTRACTOR TO FURN. AND INST. FOUR (4) 1° CONDUITS TO CASHWRAP: CASH REGISTER WIRING DETAIL 1. TENANT G.C. SHALL PROVIDE 4 INSTALL ALL NECESSARY CONDUIT WITH PULL STRINGS FOR INSTALLATION OF TENANT'S DATA SYSTEM. REFER TO DETAILS ON THIS SHEETS FOR REFERENCE OF TENANT'S DATA SYSTEM REQUIREMENTS AND ROUTING. 2. TENANT GC. SHALL INSTALL A DATA CONDUIT WITH PULL STRING FROM THE STORE'S DEMARC PANEL TO THE CASH WRAP COUNTER'S PRIMARY REGISTER 3. TENANT G.C. SI-4ALL INSTALL A DATA CONDUIT WITH PULL STRING FROM THE STORE'S DEMARC PANEL TO THE MANAGER'S DESK 4. TENANT'S DATA SYSTEM INSTALLER SHALL FURNISH AND INSTALL CAT 3 CA5LE, USING TENANT GC. INSTALL CONDUIT, FROM THE STORE'S DEMARC PANEL TO THE CA51-I WRAP COUNTER TERMINATING THE CABLE AT THE CASH AND WRAP PER WIRING DETAIL 'F'. 5. TENANT'S DATA SYSTEM INSTALL SHALL FURNISH AND INSTALL CAT 3 CABLE, USING TENANT GC. INSTALLED CONDUIT, FROM THE STORE'S DEMARC PANEL TO THE MANAGER'S DESK. 6. TENANT'S DATA SYSTEM INSTALLER SHALL LABEL JACK AT CASH WRAP AS 'CASH WRAF' JACK'. 1. TENANT'S DATA SYSTEM INSTALLER SHALL MAINTAIN A MINIMUM CLEARANCE OF 18' FROM ALL NOISE EMANATING ELECTRICAL EQUIPMENT (e.g. 5ALLASTS, POWER FEEDER CABLES, FT(') FOR THE ENflE CALE UN. S. TENANT'S DATA SYSTEM INSTALLER G1-1ALL PERFORM A CONTINUITY C14ECK FOR EACH CONDUCTOR TERMINATED AT EACH END OF THE INSTALLED CA5LES, INCLUDING CABLE SHIELD. 5. TENANT'S GC. 614ALL LEAVE ONE AS BUILT COPY OF THIS DRAWING WITH THE STORE MANAGER. Systimax Plenum Voice Cat 3 20100004BWH 107078388 305m (1000ft) 1 WE TOTE White Systimax Data Cat 3 Outlet M1BH-H-248 107321721 Systimax Surface Mounted Box M104SMB-A-246 107952442 N/A 4 ports 1/pk9 ivory 1/pkg ivory GENERAL NOTES WIRING DETAIL FOR JACKS. EACH JACK IS TO HAVE ONE CAT 3 CABLE. BLUE PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSITION *1 ORANGE PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSTION st2 GREEN PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSTION *3 BROWN PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSTION *4 SLUE PAIR FOR DSL ONLY ORANGE PAIR FOR PHONE *1 GREEN PAIR FOR PHONE *2 £3ROWN PAIR FOR FUTURE OUTLET COLOR CODE. BLUE - WHITE PIN 5 ON JACK *1 sour, BLUE PIN 4 ON JACK *1 ORANGE - WHITE PIN 5 ON JACK v2 SOLID ORANGE PIN 4 ON JACK *2 GREEN - UJWITE PIN 5 ON JACK *3 SOLID GREEN PIN 4 ON JACK *3 5ROWN - WHITE PIN 5 ON JACK *4 SOLID BROWN PIN 4 ON JACK *4 WIRING DETAIL FOR 66 BLOCK CAT 3 CABLE TO CASH WRAP WILL BE TERMINATED FIRST ON THE 66 BLOCK. CAT 3 CABLE TO THE BACK OFFICE WILL BE TERMINATED SECOND ON THE 66 BLOCK. DSL WILL BE 'BRIDGED TO THE BLUE PAIR ON THE CASH WRAP CABLE ONLY. PHONE LINE WILL E3E BRIDGED TO THE ORANGE PAIR ON THE CASH WRAP CABLE. THEN JUMFERED TO THE SACK OFFICE ORANGE PAIR IF SECOND PHONE LINE IS REQUIRED IT WILL 5E BRIDGED TO THE GREEN PAIR ON THE CASH MAP CABLE THEN Ja-IFEIREI, TO THE SACK OFFICE CABLE GREEN PAIR. 66 !BLOCK COLOR CODE CASH WRAP CA1BLE BLUE - WHITE POSTION 1 SOLID BLUE POSITION 2 ORANGE - WHITE POSITION 3 SOLID ORANGE POSITION 4 GREEN - WHITE POSTION SOLID GREEN POSITION 'BROWN - WHITE POSITION 1 SOLID BROWN POSITION 66, BLOCK COLOR CODE BACK OFFICE CABLE BLUE - WI-4ITE POSTION 9 SOLID SLUE POSITION 10 ORANGE - WHITE POSITION 11 SOLID ORANGE F'05ITION 12 GREEN - WHITE POSTION 13 SOLID GREEN POSITION 14 BROWN - WHITE POSITION 15 SOLID 5Ro1LN POSITION 16 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 2 2 2010 City of Tukwila BUILDING DIVISION RECEIVED MAR 1 7 2010 PERM!T CENTER FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: TRICARICO® Tricarico Architecture and Design PC 500 Valley Road Wayne, NJ 07470 T (973) 692-0222 F (973) 692-0223 wi,vw.tricarico.com 2010 NICHOLAS J. TRICARICO 4306 SEAL: RED NICHOLAS J. TRICARICO STATE OF WASHINGTO:' SEAL: REVISIONS NO. DESCRIPTION DATE 0 FIRST ISSUE 03/1 1 /1 0 PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO. 7010 SHEET TITLE MISCELLANEOUS ELECTRICAL DETAILS 4 0 SHEET NO. E . _ • .. DATE: 03/11/10 SCALE: AS NOTED GROSS AREA: 7180 SQ. FT. FL SALES AREA: 2,694 SQ. FT. HOH SALES AREA: 1,148 SQ. FT. PROJECT # : 100164 DRAWN BY: YW PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO. 7010 SHEET TITLE MISCELLANEOUS ELECTRICAL DETAILS 4 0 SHEET NO. E . _ • .. NOT USED TRANSFORMER HEIGHT qb" A.F.F. (V.I.F) AND MUST BE ON A DEDICATED CIRCUIT FURNISHED BY VENDOR INSTALLED BY TENANT G.G. 120V CONGEALED WIRING TO DOOR CONTACT BY VENDOR. 1 U SECURITY WIRING Alm CONTACT NOTE: TENANT E.G TO PROVIDE A PANNEX 1220 SERIES EXIT DEVICE. PROVIDE A 120V, I PH POWER WITH A DEDICATED CIRCUIT AND A LOCK -OFF DEVICE AT PANEL. OPERATED BY 10 -26V DG REMOTE POWER WITH A q VOLT BATTERY BACKUP. ZN -5 (HOLD UP) [112-- WI z CD WIRE #4 #10_ CO 0 (Y) z BACK TO PANEL ZN -4 (HOLD UP) ZN -6 (DS939) @ c ZN -7 (DS939) =1255 BURG ANNUNCIATDR (U CO (U z N z N NOTE:ALL LOCATIONS AS REQUIRED BY SECURTY VENDOR. CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO BID. ZN -1 (1082) ZN -3 (FG -730) (MONITOR) LOSS PREVENTION ALARM SYSTEM DETAIL NOT USED PANIC DOOR EXIT DEVICE NOT USED NOT USED 4p TERMINAL BLOCK ALARM SYSTEM PANEL (IF REQUIRED) MGKW J P (SALES AREA) 7 ((SAALE SG AREA) PANA -Ms DESK MODEM, FAX PHONE (MANAGER'S) NET GATE BOX CASHWRAP (SALE'S AREA) (C-ASH /LINE (SALE'S AREA) TTrE7 GODED NOTES OI 2' X 3' X 3/4" TELEPHONE BOARD WITH DEDICATED DOUBLE DUPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. REUSE EXISTING I" TELEPHONE CONDUIT FROM TENANT'S TELEPHONE SERVICE LOGATION(STOGK RM.) TO TELEPHONE CLOSET. VERIFY EXACT LOCATION IN FIELD. OBTAIN TELEPHONE SERVICE FROM LANDLORD'S TELEPHONE DISTRIBUTION CLOSET. 0 &RD TO BUILDING STEEL OR GOLD WA tEll PIPE PER N.E.G. 0 TELEPHONE OUTLET (VOICE). USE 4" SQUARE JUNCTION BOX WITH PHONE JACK AND GOVERPLATE. RUN 11 EMPTY CONDUIT WITH PULL WIRE INTO WALL, UP WALL TO STRUCTURE ABOVE, BACK TO TELEPHONE BOARD. SUMMARY OF TELEPHONE LINE REQUIREMENTS - (I) LINE REQUIRED AT BAGKWRAP FOR HANDSET (I) DEDICATED PHONE LINE AT GASHWRAP FOR CREDIT VERIFICATION, EQUIPMENT, MODEM, ETG. GAT -3 GABLE( BY CONTRACTOR) IN DATA CONDUIT WITH PULL WIRE(BY E.G.) ® TELEPHONE GABLE(BY TELEPHONE CONTRACTOR) IN 3/4 CONDUIT WITH PULL WIRE(BY E.G.) TWISTED PAIR 1 2 3 2 RJ -45 MODULAR CONNECTOR IN SIGNAL 1 TD+ 1 TD+ GROSS AREA: 7180 SQ. FT. 2 TD- HOH SALES AREA: 1,148 SQ. FT. 3 RD+ 4 NOT USED NOT USED 6 RD- 1 NOT USED 8 NOT USED RJ -45 MODULAR CONNECTOR PIN* SIGNAL 1 TD+ SCALE: AS NOTED GROSS AREA: 7180 SQ. FT. 2 TD- HOH SALES AREA: 1,148 SQ. FT. 3 RD+ 4 NOT USED NOT USED 6 RD I NOT USED NOT USED GAEL - 'S SENT ARE TERMINATED, USE ONLY AS A REFERENCE IF GABLE E- \IDS ARE RRE " COVED RJ -45 PLUG WIRING DIAGRAM TRANSFORMER SIDE OFREAR DELIVERY DOOR (EDWARDS #540) --. 120V. — BUZZER BELOW DESK MAGER2,5)DESK (MANAGER'S AREA) COMMON AT 7431LHR DELIV RY - DELIVERY DOOR (EDWARDS #I136G B) BUZZER MTD. INSIDE BAGKWRAP GOUN I Ltd (EDWARDS #725) (STOCK AREA) �— CEILING SPEKER CONDUCTORS PLENUM RATED # 16 GA. 2- CONDUCTOR, BLACK SOLID COPPER WIRE, PROVIDE JUNCTION BOX AT 48" A.F.F. AND 3/4" CONDUIT ,�- WITH PULL STRING TO 6" ABOVE FINISHED CEILING. (MANAGER'S) (SALE'S AREA) NOTE :TENANT E.G. TO FURNISH AND INSTALL CONDUIT AND PULL WIRE TO ALL AN LOCATIONS AS REQUIRED BY AN VENDOR. CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO BID. AUDIO DETAIL REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAR 2 2 2010 GIiy of Tukwila BUILDING DIVISION RECEIVED MAR 17 2010 PERMIT CENTER . CONTRACTOR SHALL INSTALL AN ETHERNET CABLE (TWISTED SHIELDED CABLE) FROM THE MANAGER'S DESK TO THE SALES AREA FLOOR ABOVE STOCKROOM ENTRANCE DOOR, TYPICALLY BELOW OR ABOVE THE EXIT SIGN. NOT DO NOT TERMINATE CABLE NEAR OR ON METAL POLES OR RACKS. 2. LABLE CABLE AT MANAGER'S DESK AS 'ACCESS POINT'. 3. CONTRACTOR SHALL INSTALL CABLE LEAVING ANY AND ALL SLACK COIL IN MANAGER'S AREA. 4. MATERIALS TO BE SUPPLIED BY FOOT LOCKER. 5. CONTRACTOR SHALL MAINTAIN A MINIMUM CLEARANCE OF 18 INCHES FROM ALL NOISE EMANATING ELECTRICAL EQUIPMENT (e.g. BALLASTS, POWER FEEDER CABLES, ETC.) FOR ENTIRE CABLE RUN. 6. CONTRACTOR SHALL PERFORM A CONTINUITY CHECK FOR EACH CONDUCTOR TERMINATED AT EACH END OF THE INSTALLED CABLES, INCLUDING CABLE SHIELD. CONTRACTOR SHALL LEAVE ONE AS BUILT COPT' OF THIS DRAWING WITH STORE MANAGER(S). a CONTRACTOR SHALL INSTALL (2) SCREWS TO BE USED TO HANG THE ACCESS POINT. TI-IE HEAD OF THE SCREWS MAY NOT TO EXCEED 1/4' IN DIAMETER THERE MUST BE A MINIMUM CLEARANCE OF S" TELEPHONE RISER DIAGRAM F REAR DOOR BUZZER SYSTEM GENERAL NOTES FOOT LOCKER, INC. STORE PLANNING DEPT 112 WEST 34TH STREET NEW YORK, NY 10120 ARCHITECT: TRICARICO® Tricarico Architecture and Design PC 500 Valley Road Wayne, NJ 07470 T (973) 692 -0222 F (973) 692 -0223 www.tricarico.com Q 2010 NICHOLAS J. TRICARICO SEAL: 4306 A�STERED NICHOLAS J. TRIC:IRICO STATE OF INASHINGTO`' SEAL: REVISIONS NO. DESCRIPTION DATE 0 FIRST ISSUE 03/11 /10 PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO 701 O SHEET TITLE MISCELLANEOUS ELECTRICAL DETAILS SHEET NO. E4 .1 DATE: 03/11/10 SCALE: AS NOTED GROSS AREA: 7180 SQ. FT. FL SALES AREA: 2,694 SQ. FT. HOH SALES AREA: 1,148 SQ. FT. PROJECT # : 100164 DRAWN BY: YW PROJECT TITLE SOUTHCENTER MALL 633 SOUTHCENTER PKWY TUKWILA, WA 98188 SPACE # 340 STORE NO 701 O SHEET TITLE MISCELLANEOUS ELECTRICAL DETAILS SHEET NO. E4 .1