Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0279 - DOLLAR TREE
DOLLAR TREE 363 STRANDER BL EL1 0-0279 City'Alkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 363 STRANDER BL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL10 -0279 Issue Date: 07/06/2010 Permit Expires On: 01/15/2011 Tenant: Name: DOLLAR TREE Address: 363 STRANDER BL , TUKWILA WA Owner: Name: REGENCY CENTERS LP Phone: Address: C/O PROPERTY TAX DEPT , PO BOX 790830 Contact Person: Name: KEVIN WEARE Phone: 206 - 795 -2629 Address: 4000 DELRIDEG WY SW SUITE 300 , SEATTLE WA Contractor: Name: POLAR ELECTRIC LLC Phone: 509 775 -0907 Address: PO BOX 854 , REPUBLIC WA Contractor License No: POLAREL974NJ Expiration Date: 08/11/2011 DESCRIPTION OF WORK: REVISE EXISTING ELECTRICAL SYSTEM FOR NEW TENANT IMPROVEMENTS TO EXISTING BUILDING Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied ami ith, Fees Collected: $608.63 National Electrical Code Edition: 2008 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction the performance . I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: 7 -2 7.-10 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 ELI 0-0279 Printed: 07 -27 -2010 City ooikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 321 STRANDER BL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL10 -0279 Issue Date: 07/06/2010 Permit Expires On: 01/02/2011 Tenant: Name: DOLLAR TREE Address: 321 STRANDER BL , TUKWILA WA Owner: Name: REGENCY CENTERS LP Phone: Address: C/0 PROPERTY TAX DEPT , PO BOX 790830 Contact Person: Name: KEVIN WEARE Phone: 206 - 795 -2629 Address: 4000 DELRIDEG WY SW SUITE 300 , SEATTLE WA Contractor: Name: POLAR ELECTRIC LLC Phone: 509 775 -0907 Address: PO BOX 854 , REPUBLIC WA Contractor License No: POLAREL974NJ Expiration Date: 08/11/2011 DESCRIPTION OF WORK: REVISE EXISTING ELECTRICAL SYSTEM FOR NEW TENANT IMPROVEMENTS TO EXISTING BUILDING Value of Electrical: NRES: $20,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: LkQL Fees Collected: $608.63 National Electrical Code Edition: 2008 Date: 6-- i (l I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. r Signature: Print Name: Lt nTh- Lon- -4 10 2e . i Date: -7/ /I 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 ELI 0-0279 Printed: 07 -06 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: Suite No: Tenant: 321 STRANDER BL TUKW DOLLAR TREE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0279 ISSUED 04/14/2010 07/06/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: V'L A mi-i-to,L,1 Date: INT° doc: Cond -Elec EL10 -0279 Printed: 07 -06 -2010 CITY OF TUKWIL Community DevelopmeNTDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: ap23 94 f b 604 Site Address: 1 sr-r,4 lJ3 t ± - Z ✓V�" Suite Number: Tenant Name: DO 1 t4- 12& Property Owners Name: .e& t1L-y (e/J4---Q 5 Go1vlltP, Mailing Address: 2'3 9 �/ D/1 j . RO4 S• /ore ,4 /Alb( r7L 6 rove_ City Name: L Ui t'J Olit41 - New Tenant: Floor: Yes ❑..No (4 . State 34/59 Zip Day Telephone: 0,2,06 7 ?S 262 9, Mailing Address: 0 0 0 ba6f �i !� $&) S'e4 City E -Mail Address: 74.P�I/ /4ti GP S r° CD /U04 b/A -Sekni 44, (AM. Fax Number: State Zip Company Name: U N' 11 eJt9 tA-) OJ - Mailing Address: City Contact Person: Day Telephone:. E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ -d� V d 0 Scope of Work (please provide detailed information): f?e- c(S e C� 1 f' ).(. S 5 --o 12 (. / vin V f`C"reLM 4 4 P x r s-{'. 0311 I a 1 Will service be altered? ❑ Yes l- No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: ret 1 ( S40e�" Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications \Forms - Applications On Line\2010 Applications \I -2010 - Electrical Permit Application.doc • bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings $152.85 $81.90 ea $59.85 ea ❑ Low voltage systems (alarm, furnace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea P itT' TE'RMIT TPL 'I ATION NOTES'= Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: iec I/1 h-( / % . //1..Y2 Mailing Address: 41O(k) Ae/r/. fj1- t.�y / � ) IDate Application Accepted: 4 Date: ell a - Day Telephone: ? 7qc- S-1■9 . City State Zip Date Application Expires: I 0, 1 Staff Initials: H:\Applications\Forms- Applications On Line\2010 Applications \I -2010 - Electrical Permit Application.doc bh Page 2 of 2 i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 321 STRANDER BL TUKW Suite No: Applicant: DOLLAR TREE RECEIPT Permit Number: EL10 -0279 Status: APPROVED Applied Date: 04/14/2010 Issue Date: Receipt No.: R10 -01238 Initials: User ID: WER 1655 Payment Amount: $499.50 Payment Date: 07/06/2010 10:09 AM Balance: $0.00 Payee: ANTHONY DORE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 100822 ACCOUNT ITEM LIST: Description 499.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 499.50 Total: $499.50 PAYMENT RFCEIIED doc: Receiot -06 Printed: 07 -06 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 321 STRANDER BL TUICW Suite No: Applicant: DOLLAR TREE RECEIPT Permit Number: EL10 -0279 Status: PENDING Applied Date: 04/14/2010 Issue Date: Receipt No.: R10 -00634 Initials: WER User ID: 1655 Payment Amount: $109.13 Payment Date: 04/14/2010 02:37 PM Balance: $436.50 Payee: RRMM ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 19489 109.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 109.13 Total: $109.13 PAYMENT RECE!VED doc: Receiot -06 Printed: 04 -14 -2010 INSPECTION RECORD 6/10'0277 Retain a copy with permit INSPECTION NO. PERMIT NO. iiiit_ CITY OF TUKWILA BUILDING DIVISION 1z' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /'Z Type of Inspection: ov Address: �� S1�Qi� /V Date Called: ',. Special Instructions: Date Wanted: f /ZD �. P.m. Requester: ff Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: eAfPfloi4 riett)( - fAiw Inspector: Date: o0 /0 Nea ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • INSPECTION RECORD 1)4'477 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '?- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 P oject; ����, Type of Inspection: .�� Addr ss: 74? s7,241/Afil Date Called: Special Instructions: Date Wanted: 0 �/ 3 a.m. rm.., Requester: Phone No: roved per applicable codes. Corrections required prior to approval. COMMENTS: 10/9 og- M/C, G11gES �KX R�l7F TdP A /S c_oN c7-6 Inspe Date /�., /O ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 3 INSPECTION RECORD fLie)— 027? Retain a copy with permi INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F'' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ProjJectt: { �- Type of Inspection: Idies. c74frilm42 e`vi) Date Called: Speciaflnstructions: - -, Date Wanted: a.m. cp3 Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: OX ��` L /4/6 GoVer, Inspecg/)/Lt ■ (/1irrt4414# Date// /// l�o ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit &o-ozrt PERMIT NO. (206)431 -3670 Project: �r , ' r � Type of Inspection: Address: 343 4' 7 ' � Date Called: Special Instructions: Date Wanted: 11( % a p.m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Polo 10 4Ec LI C*ht , CwbJi r 11-41) wief 60\)deg\ IT $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector:, Date: 0 4 oIP I� Receipt No.: Date: .�._.,., :�...-- .rccr_.�'4e-f - ra-R 1�'7. r�,- �s' k�z.,--" ��`' -_n...���.z��- �'"''.-'�^.'�+a -✓ sue:. 4.,f�`"'�rt.,.�c+ .x� INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: 32,,,t s�h Date Called: Special Instructions: Vate Wanted: 7 %am (~ rte' r Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: - Wm/ Codes Inspector: Date: 07/9/10 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: DUNHAM Ail DELIVERS. Project Memorandum Date: May 25, 2010 To: Tom Hennessey From: Adam Paulson, Phil Ramsey PROJECT: Dollar Tree- Tukwila, WA Comm. No.: 0410820 -095 Re: Code Comments This Revision to the Drawings and Specifications for the above captioned project supersedes all contrary and /or conflicting information on said plans and specifications, which are hereby amended as follows: REVISIONS TO THE DRAWINGS: This project memorandum provides a brief description of revisions made to the mechanical, electrical and plumbing drawings. Changes to this project are not limited to the items listed on this memorandum. The revised drawings shall be used as well as this document to determine project changes. Failure to utilize both the revised drawings and this document shall not result in a change order to the tenant. SHEETS El & E2 1. Revised power and lighting design near stockroom to reflect new floor plan. SHEET MP1 1. Revised HVAC design near stockroom to reflect new floor plan. REVISION Na ELlOX7d1 • P:\0410820 -095 Tukwilla, WA101- Genera115 -25 -10 PME- Revision Bulletin.doc RECEIVED JUN 012010 PERMIT CENTER 50 South Sixth Street / Suite 1100 / Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address ._ DOLLAR TREE Date 5/25/2010 , ,,,, SODTHCENTER PLA E c aaY For Building Department Use - -. -. REVIEWED FOH COMPLIANCE WITH NFPA 70 - NEC TDRWILA Applicant Name: DOLLAR 1/11»441' MO% _ _ __.. Applicant Address: Applicant Phone: 11658.0 Project Description El Plans Illufd 1 1 2010 -quirements on plans. ❑ New Building ❑ Addition .1 Alteration Indicate controls (Sections 1513) including commissioning Compliance Option Q Prescriptive Q Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA ., II _. - .. . - -faces • • :' F O : ;■ , _ Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting 0.i.. 1 'VISION 12634.6 ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area SALES RETAIL -SALES 1.50 7772:0 11658.0 STOCKROOM STOCKROOM 0.50 1470.0 735.0 NON SALES RESTROOM, COORIDOR, ELECTRICAL ROOM 0.80 302.0 241.6 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 12634.6 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES A,A1 -8' STRIP 91 98.0 8918.0 B,B1- 4' STRIP 4 52.0 208.0 STOCKROOM A,A1 -8' STRIP 10 98.0 980.0 B,B1- 4' STRIP 1 52.0 52.0 RESTROOM B,B1- 4' STRIP 2 52.0 104.0 COORIDOR 8,81- 4' STRIP . Xi.,k..,,;; ..i 2 52.0 104.0 ELECTRICAL RM B,B1- 4' STRIP ;wCS M. _KOl- 1 52.0 52.0 y.:. F WASy14 �r,4 Vli r J q ` SIONpL1 G �' i. Total Proposed Watts may not exceed To ': i ' .1. 4:a. , . is for Interior Total Proposed Watts 10418.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. REVISIONN� __ 1 E1...\Oh1. 027't RECEIVED JUN 012010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers O Other Q ualification Checklist answer If is checked type is "Other" and fees in answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) o J Check if 95 /0 or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a 1 or 2 two lamps, b reflector a) b) or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Licthtinq Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5'2'11 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia°, assembly spaces9 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall3.4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. r'- 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address DOLLAR TREE Date 3/29/2010 SOUTHCENTER PLAZA. For Building Department Use TUKWILA Applicant Name: DOLLAR TREE Applicant Address: Applicant Phone: pelf t4o. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC MAY 0 3 2010 City of Tukwila BUILDING DIVISION EL-\O ofl'1 RECEIVED APR 14 2010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address DOLLAR TREE Date 3/29/2010 SODTHCENTER PLAZA For Building Department Use TUKWILA Applicant Name: DOLLAR TREE Applicant Address: . Applicant Phone: Project Description 11658.0 ❑ New Building ❑ Addition ' Alteration a Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area SALES A,A1 -8' STRIP RETAIL -SALES .1.50 7772.0 11658.0 STOCKROOM 4 STOCKROOM 0.50 1470.0 735.0 NON SALES 98.0 RESTROOM, COORIDOR, ELECTRICAL ROOM 0.80 302.0 241.6 52.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 12634.6 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES A,A1 -8' STRIP 91 98.0 8918.0 B,B1- 4' STRIP 4 52.0 208.0 STOCKROOM A,A1 -8' STRIP 8 98.0 784.0 8,81- 4' STRIP 1 52.0 52.0 RESTROOM B,B1- 4' STRIP 2 52.0 104.0 COORIDOR 8,81- 4' STRIP 2 52.0 104.0 ELECTRICAL RM B,B1- 4' STRIP 1 52.0 52.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 10222 .0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting-Summary'(back) 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Q ualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures:. (Section 1521) 0.9 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPAZ (W /sf) Use' LPA4 (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•7•" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations8 1.0 Cafeterias, fast food establishments, restaurants/bars° 1.3 Post office 1.1 Dormitory 1.0 Retail70, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies - 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses", storage areas 0.5 Hotel banquet/conference /exhibition hall3.4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries'' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. PE V Al I CUM PLAN REVIEW /RO • NG SLIP ACTIVITY NUMBER: EL10 -0279 PROJECT NAME: DOLLAR TREE SITE ADDRESS: 321 STRANDER BL Original Plan Submittal DATE: 06 -01 -10 Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 Before Permit Issued DEPARTMENT 14 Sting D vision Public Works Fire Prevention Structural Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06-03-10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -01 -10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • latm PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL10 -0279 DATE: 04 -14 -10 PROJECT NAME: DOLLAR TREE SITE ADDRESS: 321 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bt iIding Division Wii° Public Works n Fire Prevention Structural n Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -15-10 Not Applicable Permit Center Use On!y _. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route NIX. Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -13 -10 Approved ❑ Approved with Conditions K Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 • PROJECT NAME: �6,11Gr —tree, SITE ADDRESS: le-- \ C.irmtafr- I 1 PERMIT NO: 1..1 Q— Q ORIGINAL ISSUE DATE: (pc REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 co— ( —W urn _ Summary of Revision: Roar OrA„e. ckkh4 P$ Summary of Revision: Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED - STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: City o� Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: "-7"--247-10 -10 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # fter Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner E1.16-4279 RECENED C11Y OF 1i.t+rt+un f UL272010 PERmir C akt N Project Name: 'UQ I 1 of-p. Project Address: 3 to 3 S f -INA ("-I C(6? f; . L 1 tJc Contact Person: T3 vv 5 p -18, • D u401 t s I r Phone Number: "100 3'99) -6 I 9 Summary of Revision: eh/Ay gcvolo s /31t 32/ y`a 363 p, 2010 A Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: n J - Entered in Permits Plus on of ` f([ \ H:\Applications\Forms- Applications On Line \2009-08 Revision Submittal.doc Created: 8 -13 -2004 ys Revised: 8 -2009 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director 1 REVISION SUBMITTAL 1 Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: NI Ay 20/ ZO 10 Plan Check/Permit Number: E I— I D — O27 9 ❑ Response to Incomplete Letter # Response to Correction' Letter # Revision # ) Permit is Issued b111V V ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED CITY OF TUKWILA IJUN .01 2010 feefortrow Project Name: Dollar Tree Project Address: 321 Strander Bl Contact Person: I($V I Id r V eA P . Phone Number: 2,04' 7 24,29 Summary of Revision: (-6-*- ANTTAL)# fib LC(1rR iTsp ) MINOR. GNAIiIGr6S To Pt -ArtJS iN g, PON1s,E. To ,A Mi;p1t=le,AT1ON Of I 46 PMIL-p)h46- r 6g1tA T PEaU12ltiD fY TNT PLaNN1t.1G t1'1. Sheet Number(s): e i 4 62- "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: G 4t1 Entered in Permits Plus on o6/o I Ito \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople Pr ter Friendly Page • Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Polar Electric Llc 5097750907 Po Box 854 Republic Wa 99166 Ferry Limited Liability Company UBI No. 602317730 Status Active License No. POLAREL974NJ License Type Electrical Contractor Effective Date 8/11/2003 Expiration Date 8/11/2011 Suspend Date Specialty 1 General Specialty 2 Unused ADMINISTRATOR INFORMATION License DORE *GJO55RB Name Dore', Greg J Status Active Business Owner Information Name Role Effective Date Expiration Date Dore', Gregory Partner /Member 08/11/2003 Dore', Anthony Partner /Member 08/11/2003 Dore', Robyn Partner /Member 08/11/2003 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date WESTERN SURETY CO 69776894 09/08/2004 Until Cancelled $4,000.00 09/08/2004 1 MID - CENTURY INS CO 697082815 08/11/2003 Until Cancelled 08/11/2004 $4,000.00 08/11/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type 4619 https: // fortress .wa.gov /lni/bbip /Print.aspx 07/06/2010 POWER PLAN NOTES OI WIRING DEVICES: UNLESS OTHERWISE NOTED, MOUNT EACH OUTLET BOX 50 THE BOTTOM 15 LOCATED AS FOLLOWS: SWITCH +48" - RECEPTACLE: +16 ". ADJUST TO COORDINATE WITH MASONRY IF REQUIRED. REFER TO ARCHITECTURAL DRAWINGS BEFORE STARTING WORK. OCONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH LANDLORD AND LOCAL UTILITY GO REQUIREMENTS FOR BRINGING COMPLETE TELEPHONE SERVICE INTO TENANT SPACE. <>TELEPHONE: FURNISH AND INSTALL THE TELEPHONE WIRING SYSTEM INCLUDING ALL NECESSARY CONDUIT, GABLE, DEVICE BOXES AND PLATES. A. NEW TELEPHONE SERVIGE TO TENANT'S SPACE. NEW TFI FPHONE EQUIPMENT BOARD AS REQUIRED. GOORDINATE WITH LANDLORD AND TELEPHONE GO. AS REQUIRED FOR INSTALLING THIS SERVICE. B. FURNISH AND INSTALL 3/4" CONDUIT FROM EACH TFI FPHONE OUTLET 1' -0" INTO CEILING CAVITY OR UP TO JOIST SHWERE NO CEILING 15 INSTALLED. G. FURNISH AND INSTALL TELEPHONE GABLE FROM EACH OUTLET BOX, BAGK TO TENANT'S TELEPHONE SERVICE LOCATION. GABLE SHALL BE LISTED AS COMMUNICATIONS PLENUM GABLE WHEN INSTALLED IN AN AIR HANDLING PLENUM. D. ATTACH TELEPHONE GABLES TO PHONE JACKS AND TO TELEPHONE COMPANY SERVICE CONNECTION DEVICE. COORDINATE WITH TFI FPHONE COMPANY, AS REQUIRED. 4OFIRE ALARM SYSTEM: A. IF THERE 15 NO EXISTING FIRE ALARM SYSTEM AND THE NATIONAL STATE, OR LOCAL GODES, OR LOCAL FIRE AUTHORITY HAVING JURISDICTION NOW REQUIRES A FIRE ALARM SYSTEM. FURNISH AND INSTALL DEVICES, COMPONENTS, ETC., AS DIREGTED BY ENFORCING AGENCY. 1. CONNECT FIRE ALARM GONTAGT(5) OF SPRINKLER SYSTEM TO FLOW SWITCH AND SUPERVISED VALVE AND AIR DUCT DI_TGTORS TO FIRE ALARM SYSTEM AS REQUIRED. 2. IF REQUIRED, GONNEGT FIRE ALARM DEVICES (AIR DUGT DETECTORS, ETG) AND ANY OTHER ASSOGIATED EQUIPMENT TO DEDICATED 120V GIRGUIT. B. VERIFY ALL REQUIREMENTS AND FURNISH AND INSTALL IN ACCORDANCE WITH NFPA, NATIONAL, STATE AND LOCAL GODES. LOCAL FIRE AUTHORITY HAVING JURISDICTION AND LANDLORD REQUIREMENTS. GASH REGISTER AND COMPUTER WIRING: DO NOT GONNEGT "ISOLATED" GROUND WIRE TO RAGEWAY OR BOX. CONDUIT AND BOX SHALL BE METAL AND METAL -TO -METAL GONNEGTORS SHALL BE USED (NO FLEX CONDUIT) TO ESTABLISH GROUND PATH FOR BOX AND RAGEWAY. DO NOT RUN ANY GIRGUITS WITH GASH REGISTER OR COMPUTER (IG) GIRGUITS. GASH REGISTER DATA SYSTEM GABLE SHALL BE FURNISHED AND INSTALLED BY OTHERS. FURNISH AND INSTALL JUNGTION BOX IN OFFICE AND I" CONDUIT WITH PULL WIRE TO SALES AREA CEILING CAVITY. O QUAD FINAL OUTLET LOCATION FIXTURE PLAN. PROVIDE TWO DEDICATED GIRLOCKERS. -ONE FOR EACH DUPLEX. OTELEPOWER POLE FURNISHED WITH CHECKOUT: TWO - CHANNEL TELEPOONR POLE WITH DIVIDER FOR TELEPHONE/DATA, ISOLATED POWER, AND NORMAL POWER. INSTALL TELEPOWER POLE AS SHOWN AT GHEGKOUT AREA, WHEN COUNTER 15 SET. POWER POLE WILL BE FURNISHED WITH I ISOLATED GROUND TWIST LOCK RECEPTACLE (CONNECT ISOLATED GROUND GIRGUIT TO THIS RECEPTACLE) AND ONE (1) DUPLEX RECEPTACLE (GONNEGT ONE (1) NORMAL POWER GIRGUIT TO THIS RECEPTACLE). eO CONTRACTOR SHALL SUPPLY AND INSTALL COMPACT FLOURESGENT LIGHT (GFL) BULBS IN EACH LANE LIGHT AT CHECKOUTS, (2) PER LANE LIGHT. GEL'S SHALL BE 13 WATT (EQUIVALENT TO 60 WATT INCANDESCENT), SELF BALLASTED SGREW IN LAMP NTH STANDARD BASE, HELIX (HLX) LAMP SHAPE, NON - DIMMABLE AND AN AVERAGE LIFE OF 10,000 HOURS. qOPROVIDE CONNECTION TO HAND DRYER: 120V /IPH, 1150 WATTS. PROVIDE LOCK -OFF DEVICE AT GIRGUIT BREAKER. l0 FOR INSTAL LNG TENANT SUPPLIED ENERGY MANAGEMENT SYSTEM PRIOR TO BIDDING AND INSTALLATION. <>SIGNAL SYSTEMS: REAR DOOR BELL AND PUSHBUTTON: FURNISH AND INSTALL EDWARDS #55 -665, 24V AG ADAPTABLE ABOVE CEILING AND A #852 WEATHERPROOF PUSH- BUTTON IN FLUSH (NEW CONST) SWITCH BOX AT TENANT SPACE BAGK DOOR. CONNECT 50 THAT BELL SOUNDS WHEN PUSH - BUTTON 15 PRESSED. 12 EXISTING ELECTRICAL EQUIPMENT (A5 FOLLOWS) TO BE REMOVED: (I) 200A DISGONNEGT (4) ELECTRICAL PANELS 13 EXISTING ELECTRICAL EQUIPMENT (A5 FOLLOWS) TO BE REMOVED: (2) ELECTRICAL PANELS (1) 30 KVA TRANSFORMER 14 EXISTING Fl FGTRIGAL EQUIPMENT (A5 FOLLOWS) TO BE RELOCATED: (I) 1125 KVA TRANSFORMER GONDUIT FOR EMS OVERRIDE SWITCH 2" CONDUIT FOR POINT OF SALE. GABLES BY TENANT'S VENDOR FOR WIRE ( OTENANT'S MUEAIC.) R DUPLEX RECEPTACLE (P -24) JUNCTION FOR POINT I REGN BOX WITH RIG) JUNCTION FOR EMS OVERRIDE SWITCH DUPLEX REGEPTAGLE (165362) W/ ISOLATED DEDICATED CIRCUIT (P -10) NOTE: ALL CONDUIT IN WALL TO EXTEND 6' ABOVE SALES FLOOR CEILING WITH PULL STRINGS (TYP OF ALL). ALL CONDUIT SHALL BE 3/4" UNLESS OTHERWISE NOTED. GC SHALL LABEL TOP OF CONDUIT TO MATCH LABELS ON JACKS /JUNCTIONS BELOW. JUNCTION FOR AIR PHONE (TENANT'S PAGING SYSTEM) OFF G 2 NO SCALE 2" CONDUIT (CLOSED GIRGUIT TV) DUPLEX REGEPTAGLE (165362) W/ ISOLATED DEDICATED GIRGUIT FOR CLOSED GIRGUIT TV GONNEGTION (P -26) JUNGTION FOR CLOSED CIRCUIT TV CONNECTION JUNCTION FOR SPEAKER VOLUME CONTROL 6' -0' LONG PLUG MOLD WITH (2) DEDICATED GIRGUITS (CENTERED 4 MIN OF 8 REGEPT) (P -4,6) DUPLEX RECEPTACLE (165362) W/ ISOLATED DEDICATED GIRGUIT (P -12) —QUAD PHONE JACK (RJ-11). LABEL MAIN PHONE, SPARE, D5L AND DIAL BAGK -UP, REFER TO COMMUNICATION WIRING DETAIL THIS SET. L�VAT10� NOTE: CONTRACTOR SHALL LABEL ALL PHONE JACKS /JUNCTIONS AS PER ELEVATION. ELECTRICAL EQUIPMENT SCHEDULE EQUIPMENT EQUIPMENT HP/LOAD VOLT/ DISCONNECT POWER SOURGE FI FG TAG DESCRIPTION FEEDER SIZE NOTES TYPE SIZE FUSE LOG. PANEL GB GKT# R ROOF TOP UNIT 10.1 MCA 480/3 DISG. 30 15 UNIT H 15/3 101,21,23 3/4 "G, 3#12 4 1 #12 GND 4,5,6 v R ROOF TOP UNIT 13.0 MGA 480/3 DISC. 30 20 UNIT H 20/3 25,21,2q 3/4 "G, 3#I2 8 I #12 &ND 4,5,6 v R ROOF TOP UNIT 10.1 MGA 480/3 DISG. 30 15 UNIT 14 15/3 31,33,35 3/4 "G, 3#12 4 1 #12 GND 3,4,5,6 v ROOF TOP UNIT 13.0 MCA 480/3 DISC. 30 20 UNIT 14 20/3 20,22,24 3/4 "G, 3#I2 4 I #12 &ND 4,5,6 Ki: 4 R ROOF TOP UNIT 13.0 MGA 480/3 DISC. 30 20 UNIT 14 20/3 26,28,30 3/4 "G, 3#I2 4 I #12 GND 4,5,6 v ROOF TOP UNIT 13.0 MGA 48013 DISC. 30 20 UNIT H 20/3 32,34,36 3/4 "G, 3#12 $ I #12 GNP 4 ,5,6 6 ® EXHAUST FAN 113 WATTS 120/1 5111. - - UNIT P 20/1 2q 3/4 "G, 2 #I2 $ 1 #12 &ND I III/ K BI// A\ BALER 14 A 480/3 DISC. 30 NF UNIT H 25/3 14,16,18 3/4 "G, 3#10, IMO GND ® WATER HEATER 2.0 KW 120/1 BKR - - PANEL P 30/1 23 3/4 "G, 2 #10, 1 #10 GND 2 W NOTES: I. EXHAUST FAN (EF -I) TO BE INTERLOCKED WITH RESTROOM OGGUPANGY SENSOR. SEE DETAIL 2/E2 FOR ADDITIONAL INFORMATION. 511 MECHANIGAL DRAWINGS FOR MORE INFORMATION. 2. VERIFY LOCATION OF WATER HEATER PROVIDE LOCK -OFF BREAKER @ PANEL PER NEG 422.31. PROVIDE LABEL ON EQUIPMENT INDICATING "DISCONNECT 15 LOCATED IN PANEL ". 3. PROVIDE (OR "MAINTAIN GONNEGTION ", IF EXISTING) CONNECTION TO DUGT SMOKE DETECTOR. DUGT DETEGTOR TO SHUT DOWN RTU IF AGTIVATED. SEE SHEET MPI FOR ADDITIONAL INFORMATION. VERIFY REQUIREMENTS WITH FIRE MARSHALL. 4. MECHANICAL EQUIPMENT GIRGUITRY AND CONTROL: VERIFY GIRGUIT BREAKER AND BRANCH GIRGUITRY TO BE IN AGGORDANGE WITH MANUFACTURER'S NAME -PLATE DATA REQUIREMENTS. 5. VERIFY ROOF TOP UNITS ARE FURNISHED WITH FACTORY INSTALLED SERVICE DISGONNEGT SWITCH AND WP GF1 RECEPTACLE (GKT P -41). ELECTRICAL CONTRACTOR SHALL MAKE FINAL CONNECTIONS TO SERVICE DISCONNECTS AND GFI RECEPTACLE. PROVIDE NEW AS REQUIRED. 6. VERIFY WITH MECHANICAL ROOF TOP UNIT SCHEDULE (TYPICALLY SHOWN ON SHEET MP2) IF UNIT HAS 12 KW FI FGTRIG HEAT. IF 50, TENANT VENDOR TO PROVIDE PROPERLY SIZED DISGONNEGT SWITCH AS REQUIRED. VERIFY WITH MANUFACTURERS FI FGTRIGAL DATA. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC JUN 11 2010 City of BUILDING kwila (VISION PHONE LINES BY TELEPHONE UTILITY TELEPHONE BOARD, REFER TO POWER PLAN FOR LOGATION. QUAD RJ -II JACK, REFER. TO OFFICE ELEVATION FOR LOCATION. 1 11 11 • • • • l 1 CHECKOUT (FIRST) OFFICE EMS PANEL, REFER TO EM SHEETS FOR MORE INFO. CHECKOUT (LAST) GOGO`'I"U NO SCALE \IGATIO\15 IRI COMMUNICATIONS WIRING NOTES: ® BALIWICK SHALL INSTALL A GAT 5 GABLE FROM EM5 PANEL TO FIRST CHECKOUT AND TERMINATE BOTH ENDS. 02 THE CONTRACTOR SHALL INSTALL AND TERMINATE TWO GAT 5 GABLES BETWEEN THE TELEPHONE BOARD AND PHONE/DATA OUTLET (QUAD RJ-II JACK) IN THE OFFICE. THE FOUR JACKS ARE TO BE LABELED- A) MAIN PHONE, B) SPARE, G) D5L, AND D) DIAL BAGK -UP. ONE GABLE WILL HAVE A PAIR OF CONDUCTORS FOR THE MAIN PHONE LINE WITH ANOTHER PAIR FROM THIS GABLE GOING TO THE SPARE JACK. THE SECOND GABLE WILL HAVE A PAIR OF GONDUGTORS FOR THE D5L JAGK WITH ANOTHER PAIR FOR THE DIAL BAGK -UP JACK. CQ THE GONTRAGTOR SHALL INSTALL AND TERMINATE A GAT 5 GABLE FOR THE MAIN PHONE LINE FROM THE OFFICE TO THE FIRST CHECKOUT (CLOSEST TO OFFICE). ® THE GONTRAGTOR SHALL INSTALL AND TERMINATE MAIN PHONE LINE CONNECTION FROM THE FIRST CHECKOUT TO THE LAST CHECKOUT VIA GAT 5 GABLE. IF THERE ARE MORE THAN FOUR CHECKOUTS IN THIS STORE, ONE OF THE CHECKOUTS IN THE GENTER SHALL ALSO BE GONNEGTED IN THIS DAISY GHAIN FOR THE MAIN PHONE LINE. REFER TO POWER PLAN FOR EXACT TELEPHONE LOCATIONS. Q THE GONTRAGTOR SHALL INSTALL A '66 BLOCK' TO TERMINATE ALL IN -STORE PHONE/DATA WIRING THAT ORIGINATES AT THE TELEPHONE BACKBOARD. ALL LINES SHALL BE TAGGED AT THE '66 BLOCK' (LE. MAIN, D5L, DIAL BAGK -UP, ALARM, ETC). THE PHONE COMPANY WILL EITHER TERMINATE THEIR LINES AT THE '66 BLOCK' OR AT RJ CONNECTORS ON THE TELEPHONE BAGKBOARD. IF THE PHONE LINES ARE INSTAL I Fn PRIOR TO THE ELECTRICAL CONTRACTOR LEAVING THE JOB SITE, THE FI FGTRIGAL CONTRACTOR SHALL ENSURE THAT EACH OF THE PHONE LINES INSTALLED BY THE TELEPHONE UTILITY 15 GONNEGTED TO THE APPROPRIATE LINE AT THE GONTRAGTOR INSTALLED '66 BLOCK'. BALIWIGK WILL VERIFY PHONE LINE CONNECTIONS DURING THEIR INSTALLATION. © THE CONTRACTOR SHALL INSTALL A GAT 5 GABLE FROM THE MAIN PHONE LINE AT THE '66 BLOCK' TO THE EM5 PANEL AND TERMINATE BOTH ENDS. THE CONNECTION AT THE EMS PANEL 15 A RJ GONNEGTOR. THE ELECTRICAL GONTRAGTOR SHALL MAKE SURE THIS MAIN PHONE LINE 15 GONNEGTED TO THE EM5 PANEL FOR THE CHECKOUT PROCESS OF THE EM5 SYSTEM. AFTER THE EM5 CHECKOUT PROGE55 15 COMPLETE, THE Fl FGTRIGAL CONTRACTOR SHALL UNPLUG THIS CONNECTION AT THE EM5 PANEL. WHEN THE MECHANICAL CONTRACTOR 15 READY FOR THEIR EMS CHECKOUT PROCESS, THEY SHOULD PLUG THE LINE BAGK IN AT THE EM5 PANEL AND UNPLUG AT COMPLETION OF THE CHECKOUT PROCESS. BALIWIGK WILL MAKE SURE THE EM5 PANEL 15 UNPLUGGED FROM THE MAIN PHONE LINE DURING THEIR INSTALLATION JUST PRIOR TO STORE OPENING. -TAIL MANAGERS OFFICE WHITE BLUE / BLUE MAIN PHONE WHITE GREEN / GREEN SPARE DSL WHITE BLUE / BLUE DIAL BAGK -UP WHITE GREEN / GREEN BRIDGING CLIPS (24) AIN ENO NNE mill mow NMI 0 O 0 O 0 0 0 0 0 0 0 0 0 0 O O CI 0 O O O O O 0 0 WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN WHITE BLUE BLUE WHITE ORANGE ORANGE WHITE GREEN GREEN WHITE BROWN BROWN 0 = o O O 66 BLOCK GABLE #I LABEL: MAIN PHONE LABEL: GABLE LABEL: SPARE LABEL: D5L LABEL: DIAL BAGK -UP LABEL: EM5 TELGO BACKBOARD GABLE #2 LABEL: GABLE *2 LABEL: GABLE #3 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 1 CONTRACTOR SHALL INSTALL (6) *12 AND (I) #12 COMMON GROUND IN 1" CONDUIT FROM PANELBOARD TO THE WALK -IN FREEZER/GOOLER UNIT JUNGTION BOX. INDIVIDUAL CIRCUITS ARE AS FOLLOWS: GF -6 COOLER (2) *12, (1) #12 G (COMMON) GF -8 FREEZER/GOOLER LIGHTS (2) *12, (1) 412 G (COMMON) GF -2,4 FREEZER (2) • 12, (I) #12 G (COMMON) CONTRACTOR TO PROVIDE ONE (I) JUNCTION BOX CENTERED ON THE WALK -IN FREEZER/GOOLER UNIT. ALL THREE GIRGUITS WILL TERMINATE AT THIS JUNGTION BOX. THE FREEZER/GOOLER GONTRAGSOQ WILL THEN BE RESPONSIBLE FOR THE REMAINING WORK CONNECTING TO THE UNIT. THE JUNGTION 50 WILL BE MOUNTED AT 120" .F.F. m1!!■!�tin7!lltin_ INSTALL JUNCTION BOX ®q0" A.F.F. TO BOTTOM OF BOX. ) #17,( #126,3/4 "G. INSTALL JUNGTION BOX @ q0" A.F.F. TO BOTTOM OF BOX. ' (3) #10,1 #IOG,3 /4 "G. GF -5,1 NSTALL JUNCTION BOX @ q0" A.F.F. - BOTTOM OF BOX. (3)#10,14106,3/4"G. CF-c1,11 O 1125 KVA XFMR PHONE BOARD PANEL GF PANEL P PANEL H P -2 P -8 MOUNT ON LOOR AND MAKE MG GON GTION TO� -13 DUPLEX GEPTAGLE INSTALLED IN FI RE KICK PLATO. (TYPICAL) TO TFI FPHONE BOARD (SEE DETAIL#3, NOTE 4.) • TFI FPHONE BOARD O� (SEE DETAIL #3, NOTE 4) P -3q P -I3 SECURITY GAMERA (5G) ROUGH ABOVE CEILING. PROVIDE 12' VERIFY EXACT LOCATION. —MOUNT ON FLOOR AND MAKE MG - CONNECTION TO DUPLEX REGEPTAGLE INSTALLED IN FIXTURE KICK PLATE. (TYPICAL) P -I1 Q 0 OO HALLWAY EMS CONTACTOR PANEL EMS PANEL P -13 P-15 P -I5 MOUNT ON FLOOR AND MAKE MG GONNEGTION TO DUPLEX RECEPTACLE INSTALLED IN FIXTURE KICK PLATE. (TYPICAL) P -I5 P -I5 IN MTD " WHIP. P -I5 FE P -I1 P -I1 Q ELECTRIC HAND DRYER SGHEDULE PROVIDED BY TENANT FOR TENANT'S CONTRACTOR INSTALLATION. SEE ELECTRICAL RESPONSIBILITY CHART ITEM VOLTS/PHASE KW ACCESSORIES ELECTRIC HAND DRYER 120V/14) 1.15 WALL HANGER KIT A-R PLA SCALE: I /8" = I' -0" SEPARATE PERMIT REQUIRED FOR: Mechanical Cyaectricai .ad Plumbing ,O-Gas Piping City of Tukwila BUILDING DIVISION FILE COPY permit No ,,, .122--la‘ Plan review approval is subject to errors and omissions. Approval of construction documents s does not authorize the violation of any adopted code or ordnance. Recekt of approved Field Copy and conditions is acknowledged: By ij7-t11( Date: '7l( ZO /0 City Of BUILDING DIVISION REVISION N0.1 ELtO NOTE - HVAG TEMPERATURE SENSOR: CONTRACTOR SHALL REFER TO THE TEMPERATURE SENSOR MOUNTING DETAIL ON SHEET EM -3 FOR PLACEMENT AND INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING. NOTE TO ELECTRICAL GONTRAGTOR: DOLLAR TREE ELECTRICAL EQUIPMENT SHALL BE RELOCATED AS REQUIRED TO MINIMIZE LENGTH OF CONDUIT /GONDUGTOR BETWEEN SERVIGE DISCONNECT SWITCH AND PANEL "L ". OBTAIN APPROVAL FROM DOLLAR TREE ARCHITECTURAL DEPARTMENT OF PROPOSED LOCATION PRIOR TO INSTALLATION. COST CLAIMS FOR CONDUIT /CONDUCTOR IN EXGE55 OF BASE BID WILL NOT BE CONSIDERED IF PANEL RELOCATION 15 NOT PROPOSED TO MINIMIZE TI IESE GO5T5 PRIOR TO INSTALLATION. IF YOU HAVE ANY QUESTIONS REGARDING THE FI FGTRIGAL PLANS, PLEASE GALL THE FI FGTRIGAL DESIGNER DESIGNER: PHONE/FAX: E -MAIL: ADAM PAULSON 612- 465 - 1616/612- 465 -T116 adam.paulson @dunhameng.com O ;-"7 9 RECEIVED JUN 012010 PERMIT CENTER ASSREV I ATI ONS AFF AEG EM NL GFGI ABOVE FINISHED FLOOR ABOVE FINISHED GRADE EMERGENCY NIGHT LIGHT GROUND FAULT GIRGUIT INTERRUPTER Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 FAX 612.465.7551 PHONE 612.465.7550 dunhameng.com mechanical + electrical consulting engineering a- CL Q 0 0 LO O 0 - 0 L v c O •; a) 0 0 410820 -Oa5 LU D- D < 1 c cn -0 c v 1 0 0 -c 0 RRMM ARCHITECTS, PC 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 fax (757)622 -6883 sheet El H N 120V • • WHITE BATHROOM EXHAUST FAN 4 MEN'S LIGHTS BLACK TERMINALS MEN'S OGG SENSOR WHITE BLUE TERMINALS OGG SENSOR BLAGK TERMINALS 4 WOMEN'S LIGHTS BLAGK TERMINALS WOMEN'S BLUE TERMINALS n BLACK TERMINALS SCHEMATIC E I ASRAM: BATHROOM OCCUPANCY SENSOR I /S" = I' -O" LIGHTING PLAN NOTES lOEXIT SIGNS/EMERGENCY BATTERY PACKS: CONNECT TO THE LINE SIDE OF LOCAL SWITCHING, CONTACTOR OR NIGHT LIGHT CIRCUIT: A. IN STOCKROOM INSTALL WALL MOUNTED TYPE ON WALL CENTERED I' -0" ABOVE THE DOOR OPENING. 5. IN SALES AREA, MOUNT ON CEILING 1' -0" FROM THE WALL. 2 CONTRACTOR SHALL SUSPEND LIGHTING IN 11415 AREA FROM THE BOTTOM OF EXISTING STRUGTURE. SUSPEND LIGHTING AT 10' -0" A.F.F.. PROVIDE MISCELLANEOUS MATERIALS AS REQUIRED. FIXTURES SHALL BE SEISMICALLY RESTRAINED WHERE REQUIRED BY LOGAL CODE AUTHORITY. <>TENANT STOREFRONT SIGN(S) AND FINAL CONNECTIONS WILL BE FURNISHED AND INSTALLED BY TENANT'S SIGN GONTRAGTOR. FURNISH AND INSTALL JUNCTION BOXES 11/6' WHIP ON WALL IN ATTIC SPACE. ELECTRICAL CONTRACTOR SHALL COORDINATE FINAL JUNCTION BOX LOGATION WITH SIGN VENDOR. JUNCTION BOXES NEED TO BE WITHIN 5 FEET OF SIGN FOR SIGN VENDOR TO MAKE FINAL ELECTRICAL GONNEGTION. IF STORE HAS ADDITIONAL SIDE OR REAR SIGNAGE THE GENERAL CONTRACTOR AND ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE SIGN VENDOR FOR ANY ADDITIONAL EXTERIOR SIGNAGE AND THE ASSOCIATED ELECTRICAL REQUIREMENTS. AFTER THE ELECTRICAL DESIGN 15 COMPLETE, IT MAY BE DETERMINED THAT CERTAIN SITES REQUIRE 5117E OR REAR SI GANGE. O AGPPROPRIATELY SIZED CONDUIT A CONDUIT N ND JUN TION BOXES. EAGH MULTIWIRE BRANCH CIRCUIT WITHA SHARED NEUTRAL SHALL BE PROVIDED WITH A MEANS THAT WILL SIMULTANEOUSLY DISCONNECT ALL UNDGROUNDED CONDUCTORS IN AGGORDANGE WITH THE REQUIMENTS OF NEG ARTICLE 210.4 OF THE 2008 NEG. PROVIDE CONDUIT AND WIRE SIZES REQUIRED TO MEET NEC ARTICLE 310.15(5)(2). O INSTALL EXTERIOR LIGHT ABOVE REAR 1700R IF NOT ALREADY EXISTING. PROVIDE EMERGENCY BATTERY BACKUP WITH REMOTE HEADS FOR EXTERIOR EGRESS LIGHTNG. <> PROVIDE UNSWITGHED HOT OF CIRCUIT SHOWN FOR NIGHT LIGHT (NL) AND EMERS. LIGHT (EM) FIXTURES. O EXISTING BUILDING LIGHTING TO REMAIN. ELG SHALL VERIFY IF LIGHTING 15 GONTROJ 1 FT) FROM EXISTING PANELS BEING REMOVED OR FROM LANDLORD HOUSE PANEL. IF FROM PANEL BEING REMOVED, FURNISH AND INSTALL NEW CIRCUIT FROM PANEL VIA LIGHTING CONTACTOR TO EXISTING LIGHTING. O OCCUPANCY SENSORS: INSTALL "LEVITON" OCCUPANCY SENSOR GATOLOG #05G- 10-UOW ON CEILING NEXT TO 1700R TO RESTROOM. SENSOR TIME DELAY TO BE SET TO 5 MINUTES. <> PROVIDE FLEXIBLE CONNECTION TO LIGHT FIXTURES AT EXPANSION JOINT. LIGHTING FIXTURE SCHEDULE FIXTURE SYMBOL FIXTURE LETTER TYPE FIXTURE TYPE WATTS MOUNTING PHILLIPS LAMP NOTES A S' STRIP LIGHT q8 CEILING/ SURFACE (4) 28V1 FLUOR. FURN. INTERIOR/EXTERIOR STRIP NOTES: A, G 4 G 1 c) I Al 8' STRIP LIGHT NIGHT LIGHT q8 CEILING/ SURFACE (4) 2811 FLUOR. FURN. W/FIXTURE INTERIOR/EXTERIOR STRIP WIRED AS NIGHT LIGHT. NOTE: A,G, 4 G. • NL Al 8' STRIP LIGHT EMERGENCY LIGHT q8 CEILING/ SURFACE (4) 28W FLUOR. FURN. W/FIXTURE EMERGLIGHT WITH EMERG.BATTERY BALLAST. NOTE: AGE,G,H 4 I. • EM Al 8' STRIP LIGHT EMERGJNIGHT LIGHT q8 CEILING/ SURFACE (4) 28W FLUOR. FURN. W/FIXTURE INTERIOR/EXTERIOR STRIP WITH EMERGENCY BATTERY BALLAST. NOTE: A,G,E,F,G,H 4 I. • EM/NL 6 4' STRIP LIGHT 52 CEILING/ SURFACE (2) 28W FLUOR. FURN. W/FIXTURE INTERIOR/EXTERIOR STRIP NOTES: A, G 4 G t•� 51 4' STRIP LIGHT EMERGENCY LIGHT 52 CEILING/ SURFACE ' (2) 2SW FLUOR. FURN. W/FIXTURE EMERG.LIGHT WITH EMERG.BATTERY BALLAST. NOTE: A,G,E,G,H $ I. • EM 51 4' STRIP LIGHT NIGHT LIGHT 52 CEILING/ SURFACE (2) 28114 FLUOR. FURN. W/FIXTURE INTERIOR/EXTERIOR STRIP WIRED AS A NIGHT LIGHT NOTE: AG 4 G. • NL 51 4' STRIP LIGHT EMER6JNI6HT LIGHT 52 CEILING/ SURFACE (2) 2811 FLUOR. FURN. W/FIXTURE INTERIOR/EXTERIOR STRIP WITH EMERGENCY BATTERY BALLAST. NOTE: A,G,E,F,G,H 8 I. • EM/NL ® X EXIT SIGN 5 CEILING/ SURFACE LED LAMP ARRAY W/FIXTURE LED SINGLE -FACE EXIT SIGN WITH EMERGENCY BATTERY. NOTE: D 4 1. O XI EXTERIOR WALL PACK ATLAS WLM -70MHQ 'IS WALL MOUNTED OVER DOOR (I) 7011 MH FURN. W/FIXTURE U.L. LISTED FOR WET LOCATIONS X2 EXTERIOR EMERGENCY FLOODLIGHT 15 EXTERIOR WALLIBEAMS (2)811 HALOGEN FURN. EXTERIOR EMERGENCY LIGHT WITH BATTERY. NOTES: E 8 L NOTES: A. DESIGNATED FIXTURE SHALL HAVE TS LAMPS AND ELECTRONIC BALLAST. B. GUT INSULATION (WHEN BATT TYPE 15 USED) OR PROVIDE SHIELD AROUND FIXTURE (WHEN BLOWN -IN TYPE 15 USED) TO KEEP INSULATION A MINIMUM OF 3" AWAY FROM FIXTURE. G. ATTACH FIXTURE TO T -BAR PER N.E.G. 410 -16. D. FIXTURE PROVIDED WITH DUAL VOLTAGE 120/211 POWER SUPPLY. VERIFY VOLTAGE FOR EACH FIXTURE LOCATION. E. LIGHT FIXTURE SHALL HAVE BATTERY BACK -UP WIRED AHEAD OF SWITCHES /CONTACTORS ON SAME CIRCUIT. FOR FIXTURES WITH FOUR LAMPS, THE EMERGENGY BATTERY PACK WILL ONLY OPERATE TWO OF THE LAMPS. F. LIGHT FIXTURE SHALL REMAIN ON DURING NON - BUSINESS WORKING HOURS. G. IF NO FINISHED CEILING, LIGHT FIXTURES ABOVE THE SALES FLOOR SHALL BE SUSPENDED ®12-0" A.F.F. AND LIGHT FIXTURES ABOVE THE STOCKROOM SHALL BE SUSPENDED AT IO' -0" A.F.F.. H. EMERGENCY LIGHT FIXTURES SHALL BE PROVIDED WITH IOTA IMO 2000 -LUMEN BALLASTS. I. PROVIDE q0 MINUTE MINIMUM BATTERY BACK -UP. IF YOU HAVE ANY QUESTIONS REGARDING THE FI FGTRIGAL PLANS, PLEASE GALL THE ELECTRICAL DESIGNER. DESIGNER: PHONE/FAX: E -MAIL: ADAM PAULSON 612- 465 - 7676/612- 465 -7776 adam.paulson @dunhameng.com REVIEWED WITH COMPLIANCE NFPA70 - NEC JUN 11 2010 City of .Tukwila BUILDING DIVISION •1': rl'i11mlliiii• 1 I1IIIII!UI • 1111 . ■11 .� EMPLOYE •_•__ - -o -- =4_ L HTI VS' _ PLA\ REVISION NO;L H-q LlO X 279 0 RECEIVED JUN 012010 PERMIT CENTER Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 FAX 612.465.7551 PHONE 612.465.7550 dunhameng.com w 3 mechanical + electrical consulting engineering W c o4E1',.. 10 U 0(I) 0 -0 0 CL- v E ca c O .> a) i O N O N ♦, 0 -v 410820 -Oq5 D 0_ < c 0 L_ -v N U a) U RRMM ARCHITECTS, PC 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 1 fax (757)622 -6883 sheet E2 LANDLORD FI FGTRIGAL ROOM EXISTING 200A FEEDER TO FI FGTRIGAL EQUIPMENT BEING REMOVED. CONTRACTOR SHALL EXTEND FEEDER TO NEW Fl FGTRIGAL PANEL 'H'. SEE SHEET El FOR LOCATION OF EQUIPMENT TO BE REMOVED. EXISTING 200 AMP, 2T1/480V, 3 PHASE, 4 WIRE METER (labeled "363 Maytag ") AND DISCONNECT SWITCH FUSED AT 200 AMPS. PROVIDE NEW FUSES AS REQUIRED. EXISTING 1000 AMP, 2TI/480V, 3 PHASE, 4 WIRE MAIN DISCONNECT _ SWITCH INCOMING UTILITY SERVICE I CONDUIT AND CONDUCTORS. EXISTING 1 LL MAIN t DISC. t 3 1 ( \ i —i iI 1 1 1 F� 1 METER I 1 1 L #80133a56J L . _ . J EXISTING WIREWAY -ac DOLLAR TREE SPACE E.G. TO EXTEND FEEDER TO PANEL '14' AS SHOWN. MATCH EXISTING FEEDER. PROVIDE MINIMUM 2 "G.- 443/O, I #6 CND. 3-1/2"G.-4#600, I#36 I #3 IG r RELOCATE 1 EXISTING I 1125 KVA XFMR I 480V, 3PH PRIMARY TO I I20/208V, 3PH SECONDARY I- I/4 "G. -4#3, I #86 PANEL "GF" 120/208V3PH 125A PANEL "P" 120/208V3PH 400A 2"G.-3#310,14t6J PANEL "H" 2T1/480V/3PH 225A 1 SIZE CONDUIT AS REQUIRED TO EMS CONTACTOR PANEL FOR LIGHTING GIRGUITS GIRGUITS TO LIGHT 1 I FIXTURES NEW EMS PANEL (FURN BY TENANT INSTAI I FD BY ELG) 5I= EM SHEETS L NEW EMS CONTACTOR PANFI FURN BY TENANT INSTALLED BY CONTRACTOR REFER TO EM SHEETS. MAKE ALL FINAL CONNECTIONS CONTRACTOR TO CONFIRM THAT NEUTRAL 4 GROUND BUSSES ARE BONDED IN THIS SERVICE DISCONNECT SWITCH. 1 #1 /0 TO BUILDING STEEL OR GOLD WATER PIPE NOTE: ELECTRICAL CONTRACTOR TO FIFI n VERIFY EXISTING CONDITIONS DURING PRE -BID WALK THRU TO BID. FIELD VERIFY THAT EXISTING SERVICE CAPACITY 15 ADEQUATE. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO BID. ADDITIONAL FEES DUE TO LACK OF COMPLIANCE WILL NOT BE ACCEPTED. Panel : H Voltage: 277/480V, 3PH, 4W No. Amp/p Note Description Ph Code L Code C Code R Code M Code E Code K Code D VA VA VA VA VA VA VA 1 20/1 GENERAL REC. - CASH REGISTER #1 ROW 2,4- LIGHTS VIA EMS (CUSTOMER) - A - 2652 600 $ 0 - B - 3 3 20/1 GENERAL REC. - CASH REGISTER #2 ROW 6,8- LIGHTS VIA EMS (CUSTOMER) - B - 980 600 30/ 1 REACH IN FREEZER 3 DR - C - 5 5 20/1 GENERAL REC. - CASH REGISTER #3 STOCK RM LIGHTS VIA EMS (EMPLOYEE) - C - 980 600 2 MOTOR - A - 7 7 20/1 GENERAL REC. - CASH REGISTER #4 SPARE - A - . 600 . 1 REACH IN FREEZER 3 DR - B - 9 9 20/1 SPARE EXTERIOR EMERG. LIGHTS VIA EMS - B - 192 11 2 GENERAL NOTES -C- 11 11 20/1 SPARE SPARE - C - TELEPHONE COMPANIES. 13 20/1 ITEMS REQUIRED BY THE HVAG CONTRACTOR FOR COMPLETE INSTALLATION. SPARE - A - 13 13 20/1 J -BOX SALES AREA SPARE - A - 1280 15 20/1 COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. SPARE - B - 15 15 20/1 J-BOX SALES AREA SPARE - B - 1280 17 20/1 SPARE - C - 17 17 20/1 J -BOX SALES AREA SPARE - C - 1280 19 20 /1 SPARE - A - 19 19 15 1 RTU -1 - A - 21 20/1 2522 SPARE - B - 21 21 / SPARE - B - - B - 23 - 2522 SPACE - C - 23 23 3 WATER HEATER 0 - C - • 2000 - 2522 SPACE - A - 25 25 20 1 RTU -2 - A - 27 - 3077 SPACE - B - 27 27 / SPARE - B - - B - 29 - 3077 SPACE - C - 29 29 3 - C - 112 - C - 72 - 3077 SPACE 31 20/1 31 15 1 R11J-3 - A - 360 33 - 2522 SPACE 33 20/1 33 / - B - - B - 180 35 - 2522 SPACE 35 20/1 35 3 - C - - C - 180 37 - 2522 SPACE 37 20/1 37 200 - A - PANEL 'P' LOAD - A - 500 1280 5910 4514 SPACE 39 20/1 39 / - B - VA - B - 1200 2540 2610 4514 SPACE 41 20/1 41 3 - C - 112.5 -KVA TRANSFORMER - C - 112 . 2900 3460 5180 WALK IN FREEZER 2 20/1 2 20/1 1 ROW 1,3 -LTS VIA EMS(EMPLOYEE) EM LTA -A - 2600 500 4 2 4 4 20/1 1 ROW 5,7 -LTS VIA EMS(EMPLOYEE) EM LT: - B - 1326 360 6 15/1 WALK IN COOLER 6 20/1 N. WALL LIGHTS VIA EMS (EMPLOYEE) - C - 738 360 8 15/1 1 8 20/1 20/1 S. WALL LIGHTS VIA EMS (EMPLOYEE) -A - 836 - A - 500 10 20/1 10 20/1 10 SPARE - B - I.G. OFFICE RECECPTACLES - B - 180 12 12 20/1 SPACE SPARE - C - 20/1 I.G. OFFICE RECECPTACLES - C - 180 14 25 BALER - A - 14 20/1 3878 - A - 16 / - - B - SPACE 16 20/1 3878 DED. DUPLEX RECEPTACLE - B - 18 3 18 - C - SPACE 18 3878 DED. DUPLEX RECEPTACLE - C - 20 20 1 RTU-4 -A - - SPACE 3077 20/1 I.G. REC - CASH REGISTER #4 22 / - B - 22 - 3077 22 20/1 24 3 11 -C- 24 - 3077 SPACE 24 2011 26 20 1 RTU -5 - A - 180 26 3077 SPACE 26 28 / I.G. REC - CCTV VI - B - 1200 3077 - SPACE 30 3 1 - C - - B - 3077 30 - 32 20 1 RTU-6 - A - EMS PANEL - C - 3077 500 32 - 34 / 32 - B - PANEL 'CF' - A - 3077 4514 36 3 SPACE - C - / 3077 38 20 1 EMS PHASE LOSS - A - 36 3 50 II -0- 40 / - Of - B - SPACE 38 50 SPARE - A - 42 3 40 ,. - C - • SPACE 50 20/1 SIGN - B - Through - Feed Lug ' Connection — -A- 42 - SPACE 42 . 20/1 SPARE None - B - Through - Feed Lug.' Connection — - A - Through- Feed Connection — - C - — -A- None Main 200 - A - 6588 1280 5960 25744 — Breaker / - B - 3698 2540 2660 25744 Main — 3 - C - 1830 2900 3510 26410 400 - A - 500 Breaker Notes: Conn KVA phase loads Total - A - - B - - C - 1 - PROVIDE LOCK -ON DEVICE ._- - - -._ _ 108.9 39.6 34.6 34.7 2 - i Dmd Conn Panel - Bus KVA loads 3 - - C - 15.1 12.1 Code L'Lighting 1 4 - - A - 6.7 6.7 Code C7 Convenience Receptacles (180 W) 5 - Total 12.1 12.1 Code R7 Receptacles (Non Convenience) Panelboard Notes: 80.8 77.9 Code M' Motors !Largest motorVAI 11634 1 - 1 2 - PROVIDE LOCK -OFF DEVICE Code E = Electric Heat Conn 2 - ! 2.3 Code K = Kitchen Equip ■ Demand 1 100% ' 3 - 6.7 6.7 Code D7 Dwelling Units (Hotel /Motel Rooms) 4 - 15.3 114.8 108.9 Total KVA 5- 14.2 14.2 +Spare KVA s' %Spare SURFACE : Mounting 115 Adjusted KVA (Demand KVA + Spare KVA) 22,000 : Amps AIC Rating 138 Adjusted Demand Amps 225 : Amp Rating of Bus 152 High Phase Demand Amps 1 25- May -10 200 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 480 ' : Phase to Phase Voltage PANEL H 410820-095 DOLLAR TREE CONDUIT AND WIRING AS REQUIRED TO PHOTOCELL AND OUTDOOR SENSOR ON ROOF RISER n I AGRAM NOTES INFORMATION ON THE FI FGTRIGAL SERVICE ENTRANCE 15 BASED ON THE INFORMATION REGEIVED AT THE TIME OF DESIGN FOR THIS PROJECT. EXACT INFORMATION WAS NOT AVAILABLE. CONTRACTOR SHALL VERIFY ELECTRICAL SERVICE AND ALL EQUIPMENT AGAINST THE DESIGN AND REPORT ANY DISCREPANCIES THAT GAN NOT BE RESOLVED IN THE FIFI D, TO THE ENGINEER FOR FURTHER INSTRUCTION AND /OR POSSIBLE REDESIGN OF AFFECTED ITEMS. 2. LOCATE PANEL BOARDS IN EXCLUSIVELY DEDICATED SPACES IN ACCORDANCE WITH NEG 110.26 PLUG UNUSED OPENINGS. DO NOT USE RISER DIAGRAM TO LOCATE EQUIPMENT. REFER TO POWER PLAN FOR LOCATIONS. PLUG UNUSED OPENINGS IN PANELBOARDS. 3. ELECTRICIAN SHALL BE ON SITE DURING THE DB.5. INSPECTION. 4. PROVIDE BONDING CONDUCTORS AS REQUIRED PER N.E.G. 250. RISER LEGEND DASH DOT LINE TYPE INDICATES EXISTING — • — EQUIPMENT TO REMAIN - — — — — - HIDDEN LINE TYPE INDICATES EXISTING EQUIPMENT TO BE RELOCATED CONTINUOUS LINE TYPE INDICATES NEW EQUIPMENT TO BE INSTALLED Panel : P Voltage: 120/208V, 3PH, 4W No. 'Amp /p Note Description Ph Code L Code C Code R Code M Code E Code K Code D VA VA VA VA VA VA VA 1 20/1 GENERAL REC. - CASH REGISTER #1 - A - 1 ISOLATED GROUND CONDUCTOR 600 $ 0 - B - 3 20/1 VOICE OUTLET BOX GENERAL REC. - CASH REGISTER #2 - B - THE FI FGTRIGAL CONTRACTOR SHALL FURNISH AND INSTALL A 4" SQ. X 1 1/2" D. 600 30/ 1 REACH IN FREEZER 3 DR - C - 5 20/1 . GENERAL REC. - CASH REGISTER #3 - C - 600 2 MOTOR - A - 7 20/1 DUPLEX RECEPTACLE 20 AMP, 125 VOLT (WHITE) GENERAL REC. - CASH REGISTER #4 - A - a QUAD RECEPTACLE (2) 20 AMP, 125 VOLT RECEPTACLES (WHITE) 0 JUNCTION 600 . 1 REACH IN FREEZER 3 DR - B - 9 20/1 ri SPARE - B - © BELL: 4" DIAMETER SINGLE MAGNET VIBRATING, TYPE 24 VAG, 30 VA, EDWARDS #55 -665. MOUNT ABOVE CEILING. -0 PUSHBUTTON SWITCH MOUNT 48" A.F.G. UNLESS OTHERWISE NOTED (SEE 11 2 GENERAL NOTES -C- 11 20/1 NUMBER OF CONDUITS AND CONDUCTORS, SWITGHGEAR, METERING, GABLE CHARGES SPARE - C - COST TO THE TENANT OWNER. VERIFY SERVICES AND CHARGES WITH POWER AND TELEPHONE COMPANIES. 13 20/1 ITEMS REQUIRED BY THE HVAG CONTRACTOR FOR COMPLETE INSTALLATION. SPARE - A - 13 20/1 LOCAL GODES AND ORDINANCES. IN GASES OF CONFLICT AMONG REQUIREMENTS, J -BOX SALES AREA - A - AS REQUIRED FOR VOLTAGE DROP (SEE SPECS.). ALL CONDUIT SHALL BE 3/4" 1280 15 20/1 COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. SPARE - B - 15 20/1 PROVIDED BY TENANT FOR TENANT'S GONTRAGTOR INSTALLATION J-BOX SALES AREA - B - LIGHTING FIXTURES 1280 17 20/1 SPARE - C - 17 20/1 • J -BOX SALES AREA - C - ENERGY MANAGEMENT 1280 19 20 /1 SPARE - A - 19 20/1 SPARE - A - ELEG PANELS 21 20/1 SPARE - B - 21 20/1 • SPARE - B - DISCONNECT SWITCHES 23 - SPACE - C - 23 30/1 2 WATER HEATER - C - TRANSFORMER (IF REQD) • 2000 - SPACE - A - 25 20/1 SPARE - A - TELEPHONE SYSTEM 27 - SPACE - B - 27 20/1 SPARE - B - FIRE ALARM SYSTEM 29 - SPACE - C - 29 20/1 REST RM LTS & EF -1 VIA EMS (EMPLOYE - C - 112 HVAG POWER 72 - SPACE 31 20/1 1 SECURITY - A - 360 33 - SPACE 33 20/1 PHONE BOARD - B - 180 35 - SPACE 35 20/1 DOOR BELL / BUZZER - C - 180 37 - SPACE 37 20/1 2 HAND DRYER - A - 1150 39 - SPACE 39 20/1 2 HAND DRYER - B - 1150 41 - SPACE 41 20/1 RTU RECEPTACLES - C - 900 . 20/ 1 WALK IN FREEZER 2 20/1 I.G. REC - CASH REGISTER #1 - A - 500 4 2 4 20/1 OFFICE PLUGMOLD - B - 360 6 15/1 WALK IN COOLER 6 20/1 OFFICE PLUGMOLD - C - 360 8 15/1 1 WALK IN LIGHTS 8 20/1 I.G. REC - CASH REGISTER #2 - A - 500 10 20/1 SPACE 10 20/1 I.G. OFFICE RECECPTACLES - B - 180 12 20/1 SPACE 12 20/1 I.G. OFFICE RECECPTACLES - C - 180 14 _ SPACE 14 20/1 I.G. REC - CASH REGISTER #3 - A - 500 16 - SPACE 16 20/1 DED. DUPLEX RECEPTACLE - B - 180 18 - SPACE 18 20/1 DED. DUPLEX RECEPTACLE - C - 180 20 - SPACE 20 20/1 I.G. REC - CASH REGISTER #4 - A - 500 22 - SPACE 22 20/1 STOCKROOM RECEPTACLES - B - 720 24 - SPACE 24 2011 OFFICE RECEPTACLE - C - 180 26 - SPACE 26 20/1 I.G. REC - CCTV - A - 1200 28 - SPACE 28 20/1 1 CONTACTOR COILS - B - 500 30 - SPACE 30 20/1 1 EMS PANEL - C - 500 32 - SPACE 32 100 PANEL 'CF' - A - 500 4514 - SPACE 34 / - B - 4514 - SPACE 36 3 II -0- 5108 - SPACE 38 20/1 SPARE - A - 40 - • SPACE 40 20/1 SIGN - B - 1200 42 - SPACE 42 . 20/1 SPARE - C - Through - Feed Lug.' Connection — - A - Through- Feed Connection — -A- None - B - Lug ' None - B - — - C - — - C - Main — - A - 500 Main 4514 400 - A - 500 1280 5910 4514 - B - Breaker 4514 / - B - 1200 2540 2610 4514 -C - 5108 3 - C - 112 2900 3460 5180 - A - - B - - C - Breaker Notes: Conn KVA phase Toads Total - A - - B - - C - 1 - PROVIDE LOCK -ON DEVICE 2 - 34.7 12.2 10.9 11.7 2 - PROVIDE LOCK -OFF DEVICE Dmd Conn Panel - Bus KVA Toads 3 - 2.3 1.8 Code L7Lighting 4 - 6.7 6.7 Code C7 Convenience Receptacles (180 W) 5 - 15.3 12.0 12.0 Code R7 Receptacles (Non Convenience) Panelboard Notes 14.2 14.2 Code M7- Motors Largest motor VA 72 1 - PROVIDE ISOLATED GROUND BAR 2 - Code E = Electric Heat 2 - Code K7 Kitchen Equip !Demand 1 100% ' Rooms) Code K'- Kitchen Equip Demand 100% ' 3 - Code 137 Dwelling Units (Hotel/Motel Code D7 Dwelling Units (Hotel/Motel Rooms) 4 - ! 35.2 34.7 Total KVA j 5 - ! + Spare KVA %Spare + Spare KVA t %Spare SURFACE : Mounting • 35 Adjusted KVA (Demand KVA + Spare KVA) 22,000 : Amps AIC Rating 98 Adjusted Demand Amps 400 : Amp Rating of Bus 103 High Phase Demand Amps 1 25- May -10 400 : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 208 ' : Phase to Phase Voltage PANEL P 410820-095 DOLLAR TREE SPECIAL NOTE REGARDING FI FG. SERVICE TO TENANT SPACE: EVERYTHING INSIDE BOUNDARY APPLIES WHEN 480V SERVICE TO TENANT SPACE. IF NEW 120/208V SERVICE TO TENANT SPACE, THEN PANELBOARD FEEDER (3-H, I -N, I-G, 1 -I6) 6OE5 DIRECT TO TENANT PANELBOARD. IF EXISTING I20/208V SERVICE TO TENANT SPACE 15 TO REMAIN. INSTALL IG BAR IN PANEL AND INSTALL JUMPER TO GROUND BAR ONLY. •TENANT 480- 120/208V TRANSFORMER 480V, 3PH SUPPLY WITH DEDICATED #8 GROUND TO TENANT'S Z ' 0 480V PANEL OR DISGONNEGT OR TO Z 0 L.L.'S DISTRIBUTION Z EQUIPMENT TENANT 120/208V/ PANELBOARD 0 0-1 #1 /0 AWG BONDING JUMPER PER NEC 250 -28(A) N #1 /0 AN& GROUNDING FI FGTRODE CONDUCT• PER NEG 250- 28(B), TO CLOSER OF GROUNDED METAL MEMBER OR EFFECTIVELY GROUNDED METAL WATER PIPE PER NEG 250 -28(G) IG GROUND CASE WITH LUG 0 0 NEUTRAL BAR 1 N EQUIPMENT GROUND BAR FOR NORMAL GIRGUITS INSULATED /ISOLATED GROUND BAR FOR GASH REGISTER GIRGUITS ONLY. PER NEG 408 -20. EXGI_P rION NO. I CONDUIT AND BOX MUST BE METAL TO PROVIDE EQUIPMENT GROUND PATH FOR BOX TYPICAL WIRING FOR EACH — ISOLATED GROUND RECEPTACLE ON A GASH REGISTER GIRGUIT NOTE: DO NOT RUN GASH REGISTER CIRCUITS IN CONDUIT WITH OTHER GIRGUITS N - ISOLATED GROUND ATTACHED TO RECEPTACLE ISOLATED GROUND SCREW CASH RE6ISTER OUNC I NO 1 A RAM N.T.S. Panel : CF Voltage: 120/208V, 3PH, 4W No. Amp/E Note Description Ph Code L Code C Code R VA Code M VA Code E VA Code K VA Code D VA VA VA 1 15/ 1 REACH IN COOLER 3 DR - A - B' GIRGUITS 6,S,I0. HA�I TES = NO. OF WIRES 894 SYSTEM NEUTRAL 1 ISOLATED GROUND CONDUCTOR 3 $ 0 - B - VOICE OUTLET BOX 894 THE FI FGTRIGAL CONTRACTOR SHALL FURNISH AND INSTALL A 4" SQ. X 1 1/2" D. 5 30/ 1 REACH IN FREEZER 3 DR - C - POWER AND CONTROL . 1966 ELECTRICAL PANEL 7 2 MOTOR - A - IG1:gc HUBBELL 165362 DUPLEX RECEPTACLE (ORANGE) DUPLEX RECEPTACLE 20 AMP, 125 VOLT (WHITE) 1966 a QUAD RECEPTACLE (2) 20 AMP, 125 VOLT RECEPTACLES (WHITE) 0 JUNCTION 9 30/ 1 REACH IN FREEZER 3 DR - B - ri 1966 © BELL: 4" DIAMETER SINGLE MAGNET VIBRATING, TYPE 24 VAG, 30 VA, EDWARDS #55 -665. MOUNT ABOVE CEILING. -0 PUSHBUTTON SWITCH MOUNT 48" A.F.G. UNLESS OTHERWISE NOTED (SEE 11 2 GENERAL NOTES -C- VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE JOB CONDITIONS AND VERIFY SERVICE CONNECTIONS, INCLUDING ALL NECESSARY PULLBOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, SWITGHGEAR, METERING, GABLE CHARGES 1966 TO MAKE A COMPLETE AND OPERATING FI FGTRIGAL SERVICE WITHOUT ADDITIONAL COST TO THE TENANT OWNER. VERIFY SERVICES AND CHARGES WITH POWER AND TELEPHONE COMPANIES. 13 20/1 ITEMS REQUIRED BY THE HVAG CONTRACTOR FOR COMPLETE INSTALLATION. SPARE - A - ETC.). D. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH LATEST 'N.E.C.' AND ALL LOCAL GODES AND ORDINANCES. IN GASES OF CONFLICT AMONG REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. E. ALL CONDUCTORS SHALL BE # 12 AWG COPPER. EXCEPT AS OTHERWISE NOTED OR AS REQUIRED FOR VOLTAGE DROP (SEE SPECS.). ALL CONDUIT SHALL BE 3/4" MINIMUM EXGEPT AS OTHERWISE NOTED OR AS REQUIRED FOR CONDUCTORS. 15 20/1 COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. SPARE - B - EXISTING AND /OR BY LANDLORD'S GONTRAGTOR BY TENANT'S GONTRAGTOR PROVIDED BY TENANT FOR TENANT'S GONTRAGTOR INSTALLATION SUPPLIED AND INSTALLED BY TENANT'S VENDOR COMMENTS LIGHTING FIXTURES 17 20/1 SPARE - C - • ENERGY MANAGEMENT 19 20 /1 SPARE - A - ELEG PANELS 21 20/1 SPARE - B - • DISCONNECT SWITCHES 23 - SPACE - C - OTHERWISE TRANSFORMER (IF REQD) • 25 - SPACE - A - • TELEPHONE SYSTEM 27 - SPACE - B - • FIRE ALARM SYSTEM 29 - SPACE - C - • INCLUDES HAND DRYER WALL HANGER KITS. HVAG POWER 31 - SPACE - A - • 33 - SPACE - B - 35 - SPACE - C - 37 - SPACE - A - 39 - SPACE - B - 41 - SPACE - C - 2 20/ 1 WALK IN FREEZER - A - 1654 4 2 -B- 1654 6 15/1 WALK IN COOLER - C - 1176 8 15/1 1 WALK IN LIGHTS - A - 500 10 20/1 SPACE - B - 12 20/1 SPACE - C - 14 20/1 SPACE - A - 16 - SPACE - B - 18 - SPACE - C - 20 - SPACE - A - 22 - SPACE - B - 24 - SPACE -C- 26 - SPACE - A - 28 - SPACE - B - 30 - SPACE -C- 32 - SPACE - A - 34 - SPACE - B - 36 - SPACE -C- 38 - SPACE - A - 40 - • SPACE - B - 42 - SPACE - C - Through - Feed Lug.' Connection — - A - None - B - — - C - Main — - A - 500 4514 Breaker None - B - 4514 — -C - 5108 Breaker Notes Conn KVA phase loads Total - A - - B - - C - - PROVIDE LOCK -OFF DEVICE ! 14.6 5.0 4.5 5.1 2 - i Dmd Conn Panel - Bus KVA loads 3 - ( 0.6 0.5 Code L'Lighting 4 - Code C7 Convenience Receptacles (180 W) 5 - Code R7 Receptacles (Non Convenience) Panelboard Notes: 15.3 14.1 Code Me Motors Largest motor VA I 4722 1 - I Code E . Electric Heat 2 - Code K7 Kitchen Equip !Demand 1 100% ' Rooms) 3 - Code 137 Dwelling Units (Hotel/Motel 4 - ! 15.9 14.6 Total KVA 5 - ! + Spare KVA t %Spare SURFACE : Mounting 1 16 Adjusted KVA (Demand KVA + Spare KVA) 22,000 : Amps AIC Rating 44 Adjusted Demand Amps 125 : Amp Rating of Bus 1 46 High Phase Demand Amps 1 25- May -10 MLO : Panel Amp Rating (Min Main or Bus Rating) File Name: Project Number : Project Name : 208 ' : Phase to Phase Voltage 1 PANEL CF 410820-095 DOLLAR TREE REVISION N0.1 RLliO27? AS O157:--R GROUNDING ' I /A6RAM NOTES 1. GASH REGISTER AND COMPUTER WIRING: A. GASH REGISTER AND COMPUTER GIRGUITS SHALL BE CONNECTED TO THE SAME PHASE (EVERY THIRD POSITION) IN THE PANELBOARD. FOR EXAMPLE, ALL ON PHASE A, GIRGUIT NUMBERS 1, 7, 13, OR 2, 8, 14, ETG. FURNISH AND INSTALL AN INSULATED, ISOLATED GROUND BAR IN PANEL (A). INSTALL AN INSULATED "ISOLATED" GROUND WIRE IN EACH BRANCH GIRGUIT "HOMERUN" TO PANELBOARD. CONNECT GROUND WIRE FOR GASH REGISTER AND COMPUTER GIRGUITS TO ISOLATED GROUND BAR IN PANELBOARD AND DIRECTLY TO ISOLATED GROUND LUG /SCREW ON ISOLATED GROUND RECEPTACLES. DO NOT CONNECT "ISOLATED" GROUND WIRE TO RAGEWAY OR BOX. CONDUIT AND BOX SHALL BE METAL AND METAL -TO -METAL CONNECTORS SHALL BE USED (NO FLEX CONDUIT) TO ESTABLISH GROUND PATH FOR BOX AND RAGEWAY. DO NOT RUN ANY GIRGUITS WITH GASH REGIS 1tK OR COMPUTER (IG) GIRGUITS. B. GASH REGISTER DATA SYSTEM GABLE SHALL BE FURNISHED AND INSTALLED BY OTHERS. FURNISH AND INSTALL JUNCTION BOX IN OFFICE AND 2" CONDUIT WITH PULL WIRE TO SALES, RECEIVED JUN 012010 PERMIT CENTER ER A g COMPLIANCE WITH 1 NFPA 70 NEC JUN 11 2010 City of Tukwila BUILDING DIVISION Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 Fax 612.465.7551 PHONE 612.465.7550 dunhameng.com W mechanical + electrical consulting engineering H W c O o Ua..' W �L o v O ai O 0 to c 0 .> a) L 0 N 0 'O 410520 -0q5 0 0 CL c v L 0 U -c 0 RRMM ARCHITECTS, PC 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 1 fax (757)622 -6883 sheet ES IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS, PLEASE GALL THE ELECTRICAL DESIGNER. DESIGNER: ADAM PAULSON PHONE/FAX: 612- 465 - 1616/612- 465 -1176 E -MAIL: adam.paulson @dunhameng.com LCTRICAL SYHE3OL.S (NOT ALL SYMBOLS ARE NEGESSARILY USED ON DRAWINGS) CONDUIT IN WALLS, EXPOSED OR CONGEALED ABOVE CEILING, BELOW GRADE — — UNDER SLAB OR HOME RUN TO PANEL B' GIRGUITS 6,S,I0. HA�I TES = NO. OF WIRES B -68,10 LONG HASHER = SYSTEM NEUTRAL 1 ISOLATED GROUND CONDUCTOR SWITCHES $ SINGLE POLE SWITCH (MT HT 48" AFF) MISGELLENEOUS VOICE OUTLET BOX THE FI FGTRIGAL CONTRACTOR SHALL FURNISH AND INSTALL A 4" SQ. X 1 1/2" D. OUTLET BOX WITH SINGLE GANG PLASTER RING AND NO DOVER PLATE. FLUSH MOUNT IN WALL +48" AFF TO CENTER, UNLESS OTHERWISE NOTED, AND STUB 1/2" EMT TO +12" ABOVE SUSPENDED CEILING OR JOIST SPACE IF NO CEILING EXISTS. A REVISION MARK P POWER POLE POWER AND CONTROL . ELECTRICAL PANEL EMS PANEL MOTOR I❑ DISCONNECT SWITCH (NON -FUSED EXCEPT AS NOTED) IG1:gc HUBBELL 165362 DUPLEX RECEPTACLE (ORANGE) DUPLEX RECEPTACLE 20 AMP, 125 VOLT (WHITE) a QUAD RECEPTACLE (2) 20 AMP, 125 VOLT RECEPTACLES (WHITE) 0 JUNCTION BOX I} DUCT SMOKE DE 1 IGTOR ri SIGNAL TRANSFORMER, MOUNT a' -O" A.F.F. IN STOCK ROOM AND ABOVE CEILING IN SALES AREA. © BELL: 4" DIAMETER SINGLE MAGNET VIBRATING, TYPE 24 VAG, 30 VA, EDWARDS #55 -665. MOUNT ABOVE CEILING. -0 PUSHBUTTON SWITCH MOUNT 48" A.F.G. UNLESS OTHERWISE NOTED (SEE NOTE 12) ® CEILING MOUNTED OCCUPANCY SENSOR GENERAL NOTES A. BEFORE SUBMITTING THE BID PROPOSAL, THE ELECTRICAL CONTRACTOR (ELG) SHALL VISIT THE JOB SITE AND FULLY ACQUAINT HIMSELF WITH THE JOB CONDITIONS AND VERIFY SERVICE CONNECTIONS, INCLUDING ALL NECESSARY PULLBOXES, SIZE AND NUMBER OF CONDUITS AND CONDUCTORS, SWITGHGEAR, METERING, GABLE CHARGES ETC., WHETHER SHOWN ON DRAWINGS OR NOT BUT REQUIRED BY SERVICE UTILITY GO. TO MAKE A COMPLETE AND OPERATING FI FGTRIGAL SERVICE WITHOUT ADDITIONAL COST TO THE TENANT OWNER. VERIFY SERVICES AND CHARGES WITH POWER AND TELEPHONE COMPANIES. B. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL DRAWINGS AND SPECIFICATIONS, AND SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED BY THE HVAG CONTRACTOR FOR COMPLETE INSTALLATION. G. VERIFY LOCATION AND REQUIREMENTS OF MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR, (DOOR HEATERS, UNIT HEATERS, ROOF TOP UNITS, TRAM :AIR FANS, ETC.). D. ELECTRICAL WORK AND MATERIALS SHALL COMPLY WITH LATEST 'N.E.C.' AND ALL LOCAL GODES AND ORDINANCES. IN GASES OF CONFLICT AMONG REQUIREMENTS, THE MOST RESTRICTIVE SHALL APPLY. E. ALL CONDUCTORS SHALL BE # 12 AWG COPPER. EXCEPT AS OTHERWISE NOTED OR AS REQUIRED FOR VOLTAGE DROP (SEE SPECS.). ALL CONDUIT SHALL BE 3/4" MINIMUM EXGEPT AS OTHERWISE NOTED OR AS REQUIRED FOR CONDUCTORS. F. E.G. SHALL PROVIDE ALL WIRING TO ALL SIGNS AND SHALL MAKE FINAL CONNECTIONS TO ALL SIGNS. SIGNS ARE PROVIDED BY OTHERS, ELG SHALL COORDINATE LOCATION OF ROUGH -IN WITH SIGN CONTRACTOR. SPONSI5I,I71" C -A RT ITEMS EXISTING AND /OR BY LANDLORD'S GONTRAGTOR BY TENANT'S GONTRAGTOR PROVIDED BY TENANT FOR TENANT'S GONTRAGTOR INSTALLATION SUPPLIED AND INSTALLED BY TENANT'S VENDOR COMMENTS LIGHTING FIXTURES • POWER POLES • ENERGY MANAGEMENT • SYSTEM (EMS) ELEG PANELS GIRGUIT BREAKERS • DISCONNECT SWITCHES • UNLESS NOTED OTHERWISE TRANSFORMER (IF REQD) • RELOCATE WIRING DEVICES • TELEPHONE SYSTEM lb DATA SYSTEM • FIRE ALARM SYSTEM • FI FG. HAND DRYER (TOILETS) • INCLUDES HAND DRYER WALL HANGER KITS. HVAG POWER WIRING /CONNECTION • Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 Fax 612.465.7551 PHONE 612.465.7550 dunhameng.com W mechanical + electrical consulting engineering H W c O o Ua..' W �L o v O ai O 0 to c 0 .> a) L 0 N 0 'O 410520 -0q5 0 0 CL c v L 0 U -c 0 RRMM ARCHITECTS, PC 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 1 fax (757)622 -6883 sheet ES SECTION 16010 - GENERAL PROVISIONS RELATED DOCUMENTS A. The General Conditions, Supplementary Conditions, and General Requirements apply to the Work specified in this Section. DESCRIPTION A. This Section defines the General Provisions which are common to all Sections of Division 16. B. The information in the Specifications and the Plan Drawings are basic facts to follow in determining a reasonable and competitive price for the disciplines intended. The Drawings and Specifications do not necessarily indicate or describe each item necessary for the full performance and completion of the particular work the contractor may be bidding. These documents provide the general intent necessary to inform the contractor of the Dollar Tree's desire for the systems required for Electrical. Contractor shall visit the site prior to bidding to become familiar with the existing conditions under which the work shall be performed. Failure to inspect the site will not be considered justification for an adjustment in contract price or failure to perform the work under this contract. G. Work Included: 1. All electrical work herein specified and /or shown on drawings unless noted otherwise. 2. Work by the Utility Company for which there is a backcharge. All electrical back charges to be included under this Division 16 Contract. 3. Installation shall be complete from the location designated by the Electrical Utility Company as the point of service connection, to the final connection of motors, fixtures, devices, apparatus or pieces of equipment, unless modified by Drawings or these Specifications. 4. The Electrical Drawings and specifications shall be understood to cover complete operating systems. The Drawings and Specifications are to be taken together. Work specified and not shown, or work shown and not specified shall be performed or furnished as though mentioned in both Drawings and Specifications. 5. Minor items and accessories reasonably inferred as necessary to complete such systems shall be included. All work ct materials necessary for proper operation of any system, shall be provided by this Contractor. D. Description of System: I. Complete power wiring to main disconnect switch, panels, motorized equipment, motors, equipment cabinets, and miscellaneous outlets. 2. General wiring for power, lighting, and miscellaneous systems. 3. Materials and equipment for electrical work. 4. Electric service and distribution. 5. Motor and equipment wiring, including starters, safety switches control wiring. 6. General and emergency lighting and power systems. 1. Contactors for lighting and sign control systems. s. Telephone back boxes and empty conduit. q. Arrange for sources of temporary construction services. Such services shall be nominally 120/208 volt, 3 phase, 4 wire from which a complete system of temporary power and lighting shall be installed for all construction needs and as required by the occupational safety and health departments, (OSHA). Temporary services shall be removed upon completion of work. 10. Computer system empty conduit raceway. 11. Wiring of power connections to equipment furnished and installed by others. 12. Gutting, patching, excavation and back fill, and concrete work required to complete the work of this section. Back fill shall be compacted to q5% of standard compaction. All existing surfaces shall be patched or replaced to "Like New" conditions. 13. All other equipment, material, devices, accessories required and /or shown on the drawings. E. Related work to be completed by others: 1. Computer system wiring. 2. Television system wiring. F. Definitions - As used within the Contract Document: 1. "Circuitry" or "Wiring" shall mean any electric work. 2. "Package Unit" shall mean an item of equipment having one or more motors or other electric energy consuming elements integrally factory mounted on a single base, complete with all associated control devices and interconnecting wiring. G. Permits: 1. Obtain all permits and pay all fees required for the complete electrical system. QUALITY ASSURANCE A. Qualifications: 1. Materials and equipment shall be new and shall conform to N.E.M.A. and Underwriters Laboratories (UL) standards in every case, where such standard has been established. All equipment of similar type shall be of the same manufacturer. B. Requirements of Regulatory Agencies: L All electrical work shall be in accordance with the National Electrical Code (N.E.G.), current edition, and any amendments to the National Electrical Gode made by the local Gode Officials. 2. Where applicable, all fixtures, equipment and materials shall be as approved or listed by the following agencies: a. Factory Mutual Laboratories. b. National Fire Protection Association. G. Underwriters Laboratories, Inc. (UL) d. National Electrical Manufacturers Association (NEMA) e. Americans with Disabilities Act (ADA) G. Allowable Tolerances: 1. Review Architectural, Structural and Mechanical Drawings for all dimensions, locations, partitions and walls, structural details, and location of mechanical pipes and ducts 50 that the electrical installation shall be in coordination with that of the other trades. Exact location and electrical requirements of equipment furnished by other trades and wired by this Contractor shall be obtained from the Drawings of the other trades. APPROVAL DRAWINGS A. Prepare and submit for approval such additional electrical drawings, diagrams, and specifications as are required by: I. Local Fire Prevention Bureau 2. Local Building Department - Electrical Inspection Section 3. Local Utility Companies COORDINATION AND COOPERATION A. The contractor shall examine the premises and satisfy himself of existing conditions under which he will be obligated to operate in performing his part of the work or that will in any manner affect the work under the contract. The Contractor shall cooperate with other trades so that the installation of all equipment may be properly coordinated. B. All equipment furnished shall fit the space available, with connection, etc., in the required locations and with adequate space for operating and servicing. The drawings are generally diagrammatic and indicate the manner and method of the installation while the specifications and fixture list denote the type and quality of material and workmanship to be used. Where a conflict exists between the drawings and the specifications, the Contractor shall promptly notify the Architect whose decision shall be final. No allowance will be made subsequently in this connection on behalf of the Contractor after award of the contract. GUARANTEE A. Provide one year guarantee for all fixtures, equipment, materials and workmanship, upon final acceptance by Dollar Tree. Any defective material or faulty workmanship shall be replaced without cost to Dollar Tree. PROTECTION A. The contractor shall be responsible for protecting all equipment and systems against harmful exposure, or accumulation of dust /moisture, flooding, corrosion, or other forms of damage. Glean and restore damaged finishes and equipment to place installation in a like -new condition. 1 NSTALLATION /APPL (GATI ON /PERFORMANGE/EREGTI ON A. Application, Installation: 1. No measurements of a Drawing by scale shall be used as a dimension to work by. The drawings are not intended to show complete or accurate details of the building in every respect. Exact locations and relations are to be defined in the field and shall be satisfactory to the Architect/Engineer. This Contractor shall take all field measurements and shall be responsible therefore. 2. Compare Drawings and Specifications, checking all measurements and determine intent of Contract Documents. Discrepancies shall be brought to the Architect/Engineer's attention for interpretation prior to any installation. 3. The right is reserved to make any reasonable change in location of outlets and equipment prior to roughing -in without involving additional expenses. Any change from the Electrical Drawings as is necessary to make the work of this Contractor conform to the building as constructed and to fit the work of other trades shall be included in Contractor's Contract and installed without extra cost. 4. Perform all work in compliance with all applicable safety regulations including OSHA regulations. 5. Coordinate all work with other trades prior to any installation. 6. Provide code approved clearances around electrical equipment. 1. Coordinate staging of material with building management representative at time of bidding. FIELD QUALITY CONTROL A. Testing: 1. After wires are in place and connected to devices and equipment, the system shall be tested for shorts and grounds. All hot wires, if shorted or grounded, shall be removed and replaced. 2. All meters, instruments, cable connections equipment, and apparatus necessary for making all tests, shall be furnished by this Contractor at his own expense. ADJUST AND GLEAN A. Gleaning Equipment, Completed Work and Premises: After the completion of all installations, each system shall be thoroughly cleaned to remove all paint, oil and other foreign material. Contractor shall also clean all foreign paint, grease, oil, dirt, labels and stickers, etc., from all fixtures, equipment, etc. The Contractor shall remove all rubbish, debris, etc., accumulated from his operations from the premises. APPROVALS A. Obtain all permits and approvals from the governing bodies which have jurisdiction over this project. IDENTIFICATION AND TAGGING A. Identification of distribution switches or circuit breakers individually mounted or of panel boards shall be by means of engraved lamacoid nameplates permanently fastened on the front face of the housing, showing 1/4" high white lettering on a black background. Provide all panel boards with typewritten directory. SLEEVES A. Provide sleeves in walls and floor slabs for the passage of all conduits, pipes and ducts installed. Sleeves shall be set in place in sufficient time, ahead of concrete work, 50 as not to delay that work. • GUTTING AND PATCHING A. Perform all cutting and patching required to complete the Work, except where specifically shown on the Architectural or Structural Drawings. Patching shall match existing and shall be coordinated with Dollar Tree's representative. SECTION 16010 - BASIC MATERIALS AND METHODS MATERIALS A. Conduit: 1. Electrical Metallic Tubing: EMT, "Thinwall" conduit shall in general be utilized where permitted by Gode except where described herein. Minimum size conduit shall be 3/4 ", unless specifically noted otherwise. 2. Heavy -wall steel conduit and I.M.G. shall be either hot dipped galvanized or sherardized. 3. Flexible conduit shall be Greenfield type except, where exposed to oil, grease, or water - conduit shall be Sealtite. 4. Plastic conduit shall be PVG Schedule 40. 5. Conduit shall be as manufactured by Allied, Triangle or approved equal. 6. Provide expansion fittings for conduits crossing expansion joints. �i. Conduit Fittings: a. Rigid: Threaded. b. Thin -Wall: Compression Type. c. Flexible: Connectors shall be compatible with flexible conduit used. 8. Provide bushing and lock nuts for all conduit entries to boxes. B. Wires and Gables: I. Unless specifically noted otherwise, all wiring shall be installed in conduit. 2. All wire shall be type THIN or THWN copper. No aluminum conductors will be allowed. 3. Wire smaller than 4t8 shall be solid: #8 and larger, stranded. 4. Gable and wire shall be as manufactured by Triangle, General Gable, Canada or Carol. G. Color Coding: Golor coding shall be used throughout the entire electrical system. Provide industry standard color coding for the voltages involved. Control wiring shall be numbered for easy identification of terminal points. Number terminal blocks accordingly. D. Disconnect Switches: 1. Switches shall meet NEMA enclosed switch standards K5I, current edition. Switches shall be quick -make, quick -break so that operation of the contacts shall not be capable, during normal operation of the switch, of being restrained by the operating handle after the opening or closing of the contacts has started. 2. All safety switches shall be heavy duty of voltage matching equipment served. NEMA I for indoor use and NEMA 3R for outdoor use. Switches shall be as manufactured by Westinghouse, General Electric, Square D, or Siemens. E. Fuses: Furnish and install all fuses. Fuses shall be as specified on the Drawings. F. Outlet, Pull and Junction Boxes: Outlet, pull and junction boxes shall be 12 gauge, or heavier, steel, with removable knockouts. Boxes shall be as manufactured by Appleton, Steel City or Raco. Size boxes as required for the intended duty, minimum size as required by the National Electrical Code. G. Switches: 1. Wall switches shall be located as indicated on the Drawings, arranged singly or in gangs and at the height specified or indicated and shall have proper covers with finishes specified herein. Switches shall be as follows unless otherwise called for on Drawings or hereinafter specified. a. Switches, 20 amperes, 120/211 volt specification grade, quiet rated: by Leviton, Eagle, HUBBELL, or Pa55 $ Seymour. Switch shall be White. H. Receptacles: 1. Receptacle shall be located as shown on the Drawings and at the heights specified or indicated. Receptacle and power outlets shall be of the grounding type specification grade and as manufactured by HUBBELL, General Electric, Pass $ Seymour, Eagle or Leviton. Receptacle shall be White. 1. Switch and Receptacle Plates: 1. Plates in finished areas for switches and receptacles shall be white. Identify all dedicated circuits with a laser printed adhesive label indicating panel and circuit number. J. Contractor shall provide all elbows, connectors, etc., and install outlets complete. K. Lighting and Appliance Panel boards: 1. Panels shall be type indicated on the Drawings, with main lugs, main breakers, branch breakers, spares and spaces as scheduled. 2. Panels shall comply with U.S. Federal Specification WPI15a, Type 1, Glass 1. 3. All circuit breakers shall be bolt -on type. 4. The Contractor shall balance all circuits. All conductors shall be continuous without splicing from last outlet to their terminals in cabinet. Contractor shall provide a directory of circuits for cabinet. Directory shall be typewritten designating room or equipment and circuit numbers, include any existing circuits which remain. 6. Where 2 or 3 pole breaker units are called for, they shall be on unit with common trip and not single pole units with handle ties. Capacity of main busses shall be as shown on the Drawings. 1. Panel boards shall be manufactured by Westinghouse, Square D, Siemens or General Electric. L. Outside Delivery Door Bell: A Bell system shall be furnished and installed by the contractor including 24 Vac transformer and wire. Bell shall be Edwards Gat. #55 -665. Push - button shall be Edwards Gat. #852 with stainless steel plate. PREPARATION /INSTALLATION/ APPLICATION A. Conduit: I. Installation - All conduit shall be sized in accordance with the N.E.G.. a. Conduit to be run exposed in unfinished areas such as mechanical and electrical room used as electrical closets. All other conduit shall be concealed. b. All conduit and wiring shall be concealed wherever possible. Where conduit and wire cannot be concealed, obtain direction from the Architect. No surface mounted conduit, wiremold or power poles will be acceptable, unless specifically indicated on the drawings. c. All exposed conduits shall be run parallel to or at right angles to structural members. Carefully coordinate exact routing with the Architect's representative, in the field, prior to any installation. d. All conduit shall be independently supported from the building structure. Conduit shall not be suspended from ventilating ducts, mechanical piping, suspended ceiling grids, or their hangers. e. All conduit shall be mechanically and electrically continuous from outlet to outlet and box to box. Secure conduit fittings at all enclosures and junctions. Types of Conduit: a. Conduit, within building confines run in concrete slabs, within outside masonry walls, in earth fill, and exposed in wet areas shall be galvanized steel heavy wall or IMG. Couplings for conduit run in poured concrete shall be concrete tight. b. Conduit run exposed or outdoors shall be galvanized steel heavy wall or IMG with watertight fittings and boxes. c. Conduit run in dry areas within building confines shall be EMT, except where specifically noted otherwise or prohibited by local codes. Dry areas are inside partitions, ceiling cavities, above grade slabs, and areas not subject to damage. d. Conduit with trade sizes over 1 -1/2" and /or exposed in mechanical rooms shall be galvanized steel heavy wall or IMG. e. Conduits run under floor slabs and in contact with earth may be PVG Schedule 40 encased in concrete. 3. Provide full size ground wire in all conduits, PVG or Metallic. Where the drawings do not identify the size of the equipment ground wire, it shall be the same size as the phase conductors. B. Boxes, outlets and cabinets: Install equipment and materials in a neat and workmanlike manner and align, level and adjust for satisfactory operation. Install equipment so that all parts are easily accessible for inspection, operation, maintenance and repair. Provide the design, fabrication, and erection of supplementary structural framing required for attachment of hangers or other devices supporting electrical equipment. Rigidly mount all boxes and provide with suitable screw fastened covers. Plug open knockouts or holes in boxes with suitable blanking devices. 2. Center all outlets with regard to paneling, furring, and trim. Symmetrically arrange outlets in the room. Satisfactorily correct outlets improperly located or installed. Repair or replace damaged finishes. Set outlets plumb and extend to the finished surface of the wall, ceiling or floor without projecting beyond same. G. Fire and Smoke Partition Penetrations: I. The Contractor shall familiarize himself with all fire rated construction and install his work so as to maintain the integrity of the fire code rating. Maintain rating of fire rated and smoke rated construction. Sleeves shall be steel or pre- manufactured sleeves similar to Pipe Shields, Inc., for bare pipe through fire walls and floors, model WFB, DFB or QDFB. For plastic pipe, use type WFB with one inch thick calcium silicate insulation encased in metal sleeve extension two feet either side of fire rated walls or floor. Seal annular space around conduits. For fire and smoke rated floors, walls and partitions, use UL listed material that maintains fire rated wall and floor integrity, similar to RTV foam, Dow Corning "Fire Stop" or Pipe Shields, Inc., model WFB, DFB, or ODFB. For non -rated walls and partitions, use mineral or glass fiber insulation. SECTION 16400 - SERVICE AND DISTRIBUTION DESCRIPTION A. Work Included: 1. Current transformers cabinet. 2. Main switchboard. 3. A complete distribution system. 4. System grounding per local codes. 5. All work and charges required by the local utility company. B. Services: 1. Incoming electrical service is as indicated on drawings. EQUIPMENT A. Main switchboard shall be service entrance rated and front accessible with removable screw - on cover plates. Grounding and metering shall comply with the local utility company and all local code requirements. DISTRIBUTION PANEL BOARDS A. Panel board shall be enclosed in steel cabinet of rigidity and gauge of steel per UL Standard #50 for cabinets. All panel boards shall be provided with door locks, all keyed alike. B. Bus structure shall be copper. G. Short circuit current rating shall be equal to or greater than the available short circuit at the panel board, but not less than 50,000 amperes symmetrical. D. Panel boards shall be as shown on the drawings with main lugs, main breakers, branch bolt -on breakers, spares and spaces as scheduled. Provide G.F.I. breakers as required. Panel boards shall be manufactured by General Electric, Westinghouse, Square D or Siemens. Provide a typewritten panel directory for each panel, identifying the use of each circuit including any existing circuits which remain. CONNECTIONS A. All main feeder connections shall be made with solderless connectors, bolted type. Smaller wire splices shall be made with pressure type connectors - Minnesota Mining "SKOTGHLOGKS" or Ideal "WINSNUTS" INSTALLATION A. System Grounding: I. Shall be in strict accordance with the National Electrical Gode, Local Governing Authorities and in accordance with the recommendations of the Utility Company. See details on drawings for additional grounding requirements. B. Electrical Service: I. The Utility Company will furnish, install and connect all primary service conductors. j2. This contractor shall contact the Utility Company and Landlord to obtain all information necessary for the work, incorporate their instructions into the work, and obtain their approval of all work and material. Include all costs in base bid. SECTION 16500 - LIGHTING SYSTEMS AND CONTROLS DESCRIPTION A. Work Included: I. Contractor to install lighting fixtures with lamps, hangers and controls as shown on Drawings and Lighting Fixture Schedules. Dollar Tree will provide all lighting fixtures, lamps, spacers, fixture trim and accessories as required for a complete secure and working installation. B. Requirements I. All fluorescent lamp including PL shall be 4IK color temperature, G.E. or approved equivalent. All lamps shall be T -8 type, unless specified otherwise. Provide all lamps as indicated on the lighting fixture schedule, or as recommended by the fixture manufacturer. 2. All fluorescent lamp ballasts shall be electronic type with maximum 10% total harmonic distortion (THD). 3. Provide all exit and emergency lighting as required by applicable code(s). SECTION 16-100 - COMMUNICATIONS DESCRIPTION A. Work Included: 1. Empty backboxes and conduit shall be furnished and installed by Contractor. TELEPHONE SYSTEM /COMPUTER SYSTEM A. Telephone System Grounding Conductors: Furnish a #6 AWG, copper grounding conductor from each telephone service equipment to respective electrical service grounding electrode system. B. Telephone /Computer Conduit System: Furnish as indicated on the Drawings, including the following: 1. Telephone service conduits for underground service. 2. Other conduits as indicated on the Drawings. Furnish #14 AWS soft iron pull wire or heavy nylon cord in each conduit for pulling the telephone cable to each termination point. 3. Outlet boxes with a 3/4" conduit stubbed into accessible ceiling space with pullwire for cabling by others. Provide separate dedicated conduits for P.0.5. lines. (Do not share with other telephone or data lines.) G. No electrical conduits or power wiring shall pass over the telecommunications closet and panels, except for telecommunications room light fixtures. INSTALLATION A. Furnish and install conduit system as shown. Cabling and final connection to be by the Dollar Trees contractor. The system shall consist of telephone /data outlets in locations as indicated, branch conduits, and all accessories required by the telephone company for complete installation. DESCRIPTION A. Work Included: 1. All work shall comply with the latest National Electric Gode (N.E.C.) and all local codes. Coordinate exact code requirements and local amendments with local inspector prior to any installation. 2. Contractor shall contact the Utility Company and incorporate all requirements into the new work. 3. Ground in accordance with the N.E.G. and all local codes. Refer to details for additional information. 4. Assumed available fault current is 50,000 amps R.M.S.. Contractor shall verify with Utility Company representative and report any discrepancies to Architect/Engineer prior to ordering equipment. 5. Provide fuses at all locations shown on the drawings or required for supplemental protection. Where amp rating of protective device 15 600 amps or less, provide Sussman low -peak current limiting fuses, Glass RKI on panels; RK5 (with dual element Fusetron up to 100 A; above 100 A dual element Low Peak), having an interrupting rating of 200,000 amps RMS, unless noted 601 amps, provide Sussman "Limitron" fuses, Class "L ", having an interrupting rate of 200,000 amps RMS unless noted otherwise. Provide similar type, "Hi -Gap" fuses where shown. REVISION NO1L EL1O OZ79 COMPLIANCE NFPA7pCEWITH NEC JUN 11 2010 BVICity N f TukWila DIVISION RECEIVED JUN 012010 PERMIT CENTER z z Dunham Associates, Inc. 0 aio O r 3 l% as m 2 2 ED x ro O 0 0 M FAX 612.465.7551 PHONE 612.465.7550 N 0 co as E O d a) s • 0 •Ca t 0 0 • E 1- Z 2 c O 0 0 ♦' 0 U 0 -0 0 0 Cv E 0 N a� 0 410820 -015 0 4) 0 L 0 ii z c 0 L a) 0 a� -c U RRMM ARCHITECTS, PC 1317 Executive Blvd, Suite 200 Chesapeake, VA 23320 (757)622-2828 1 fax (757)622 -6883 sheet E4