Loading...
HomeMy WebLinkAboutPermit EL10-0364 - BAJIO MEXICAN GRILLBAJIO MEXICAN GRILL 7100 FUN CENTER WY SUITE 140 EL1O-0364 City o*Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL10 -0364 Issue Date: 07/02/2010 Permit Expires On: 12/29/2010 Tenant: Name: BAJIO MEXICAN GRILL Address: 7100 FUNCENTER WY SUITE 140 , TUKWILA WA Owner: Name: H2 OFFICE LLC Phone: Address: 7100 FUN CENTER WAY STE 100 , TUKWILA WA Contact Person: Name: MARK BEDNAR Phone: 360 - 458 -2927 Address: PO 982 , MCKENNA WA Contractor: Name: OTI SERVICES INC Phone: 360- 458 -2927 Address: PO BOX 982 , MCKENNA WA Contractor License No: OTISESI940Q 1 Expiration Date: 11/21/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW RESTAURANT TENANT IMPROVEMENT Value of Electrical: NRES: $21,887.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $588.62 National Electrical Code Edition: 2008 Date: / — ( 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performances' work. I am authorized to sign and obtain this electrical permit. Signature: 7110 eSe- Date: �' — Print Name: Q1// , sPc C This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL10 -0364 Printed: 07 -02 -2010 � r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2423049092 Address: Suite No: Tenant: 7100 FUN CENTER WY TUKW BAJIO MEXICAN GRILL PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0364 ISSUED 05/19/2010 07/02/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: )'-42 ^� doc: Cond -Elec EL10 -0364 Printed: 07 -02 -2010 CITY OF TUKWIAIP Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Electrical Permit No. CL 10- o q Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 7100 Fun Center Way Tenant Name: Bajio Mexican Grill King Co Assessor's Tax No.: at-0_ 30 c/ 90 Suite Number: 140 Floor: 1 New Tenant: IZ1 Yes ❑..No Property Owners Name: "c p `t ( / A Mailing Address: ) /e) 0 fk-rt CP vi /eke. 0, QK °/yO FkkW (/Q X)4 City State Zip CONTACT PERSON -Who do - ontact when your permit is ready to be issued Name: Mark Mailing Address: PO 982 E -Mail Address: mark @otisvcsinc.com Day Telephone: (360) 458 -2927 Mckenna WA 98558 City State Zip Fax Number: (360) 458 -2927 ELECTRICAL CONTRACTOR INFORMATION Company Name: OTI Services Inc. Mailing Address: PO Box 982 Contact Person: Mark Mckenna WA 98558 E -Mail Address: mark @otisvcsinc.com Contractor Registration Number: OTISESI940Q1 City Day Telephone: (360) 458 -2927 Fax Number: (360) 458 -7076 Expiration Date: 11/21/2010 State Zip Valuation of Project (contractor's bid price): $ 21,887 Scope of Work (please provide detailed information): New Restaurant Tenant Improvement Will service be altered? ❑ Yes 0 No Adding more than 50 amps? ❑ Yes 0 No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel 0 Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: O Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line \2010 Applications \ 1-2010 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mark Bednar Mailing Address: PO 982 IDate Application Accepted: S-Lyif 4� Day Telephone: Mckenna City Date: 05/18/2010 (360) 458 -2927 WA 98558 Date Application Expires: 4 (...s111.0 H:\Apphcaaons \Forms - Applications On Lne\2010 Apphwtiom \1 -2010 - Electrical Pemut Application.doc bh Page 2 of 2 State Zip Staff Initials: 1 /4( • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2423049092 Address: 7100 FUN CENTER WY TUKW Suite No: Applicant: BAJIO MEXICAN GRILL RECEIPT Permit Number: EL10 -0364 Status: APPROVED Applied Date: 05/19/2010 Issue Date: Receipt No.: R10 -01230 Initials: WER User ID: 1655 Payment Amount: $470.90 Payment Date: 07/02/2010 01:42 PM Balance: $0.00 Payee: OTI SERVICES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7671 470.90 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 470.90 Total: $470.90 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -02 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 2423049092 Permit Number: EL10 -0364 Address: 7100 FUN CENTER WY TUKW Status: PENDING Suite No: Applied Date: 05/19/2010 Applicant: BAJIO MEXICAN GRILL Issue Date: Receipt No.: R10 -00883 Payment Amount: $117.72 Initials: WER Payment Date: 05/19/2010 02:05 PM User ID: 1655 Balance: $470.90 Payee: OTI SERVICES INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7657 117.72 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 117.72 Total: $117.72 PAYMENT RECEIVED (Inn. RPnaint -nF Printp.d n5 -14 -2010 INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. .CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 fLoo3( LQ Project: � 1v ` 11 (s_ Type of Inspection: 0 Address: 700 � � , �� Date Called: Special Instructions: Date Wanted: F /3/ P.m. Requester: Phone No: y�,Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: f?JJtoJ i d Inspector: Date: tig73//10 n REINSPECTIOtV FEE REQUIRE . Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'g 640-o3(91/ 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 C6 (206) 431-3670,1, Project: /% (O } ��`f� ,Iw�J Type of Inspection: OD Address ii loo ,Y Date Called: Special Instructions: Date Wanted: a.m; . Requester: Phone No: ElApproved per applicable codes.. Corrections required prior to approval. COMMENTS: — /AT iv &c-1> Ar tjk `(L. Sou fr 6 4t z- D,Sr^oAid6 T S 04 e -ski eAt >2 00 - raoeTD P e milt r OM 12. PrideT4--004 Sf*,_ - 0$c I r -o45 :o(Z s ,©l) 6k J4I C,. /,J l6c..noA) Li4h 0411-5 W1^14 yap et r, uwTE, 4 rC(kc r((R-rn &1> Dt4Abur e r (c44A ) I Date: 24,d Inspector: &ANIS REINSPECTION FEE REQUIRED. Prior to next ins p ecti n fe must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 6,10- o3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 - 3670`( Permit Inspection Request Line (206) 431 -2451 VI Project: �/ t 1Q 1` . 1 CAA Type of Inspection: ° ,_: /' Address: 716o AI( Date Called: r Special Instructions: . Date Wanted: �P- (gen. Requester: II Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: DX_ c6- C0J Red �('i 60 66-76 Inspector: 6"16\ Date: OV 26 10 REINSPECTION EE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSP'CTION NO. CITY OF TUKWILA BUILDING DIVISI ON 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit fiio1.o37' (- PERMIT NO. (206)431 -3670' jl Project: Pro f - flo ctiu.. YP e of Ins ection: 7oc,3 - fl{cia541 '-c .sPua 4oriPtAtirref 19 Address: 7/00 4NYTIZ. IA)/. Date Called: S P4 . (56e 700 t .4o1A ) Special Instructions: Date Wanted: Y LO aCJ Requester: Phone No: Approved per applicable codes. RICorrections required prior to approval: COMMENTS: — &f &O?( ' 1A Cii, JC1 - fl{cia541 '-c .sPua 4oriPtAtirref 19 A•JS d L 64c.- oS-J2:�� - 2" PJc To . BF 5-.) PPot &%4 S P4 . (56e 700 t .4o1A ) A-tbl noel Mc 5OPP0& AT 1,14ffl,J S- ICJ ITGII- J /Coil vir r4 rt 1X — (o/_.5 It ,Z e9ilP4rr Inspector: Date: 03/240 D $60.00 REINS ECTION FEE REQJIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION tC.' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with perm PERM Proiec ` i �/J� /'2 �/l / 4 Type of Inspection: ^i� ' /�) �/ ✓� Address: _ le^ ` ,`fin Aly y Date Called: 72 /E ;r' ,C /.sM/ <- c/bd Special Instructions: -C.4.7)1/C- Date Wanted: ^ // /J( / a.m. p.m. Requester: Phone No: --s.)( n Or //1)$7 ❑ Approved per applicable codes. rrections required prior to approval. COMMENTS: j) >VSAVC- i )ARE5 T� AE /177A(//4/ F/ V7M E C 2 72 /E ;r' ,C /.sM/ <- c/bd ;*; , f)"lib -C.4.7)1/C- ‘Ce/Wr. TV AW< 1-./611 77/4- V --s.)( n Or //1)$7 /J F(/ o Inspecto, 44,4/ymoll Date %/ / O ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Oa- O3(ati PERMIT NO. ;12 (206)431 -3670 Project: bpao ,/� ^ T .L Type of Inspection: 700, Address: ifoo 64 �V i to Called: Special Instructions: Date Wanted: 70y a p.m Requester: Phone No: , ElApproved per applicable codes. ❑ Corrections required prior to approval. 7,2"7" COMMENTS: ?t, - co acv wau�j Inspector: Date: 07/40 ' !v ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: LOAD CALCULATIONS Existing 200Amp H2 Office Suite 100 Panel "COMM Lighting 14- Two lamp Troffers x 68Watts = 884 Lighting 9 - Recess Compact Fior x 26 Watts = 234 Receptacles 40 x 175 Watts = 7000 Roof Top Unit 24 Amps x 208 x 1.73 = 8636 REVIEWEFO0 y ° C NFPIANCE WITH o A70-NEC 0 0 JUN 01 2010 0 0 City of Tukwila 0 BUILDING DIVISION 0 0 0 0 0 0 0 0 0 TOTAL = 16754 DIV.BY 208/1.73= 47 RECEIVED MAY 19 2010 PERMIT CENTER £LlO O3(o1 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC JUN 0 1 2010 City of Tukwila RI III DIN( DIVISION AOMgt -1) 4 Pormft No., /PI tnnr■••,.• •••■ - - ... • • ELI o RECEIVED MAY 19 2010 PERMIT CENTER Page 1 BAJIO MEXICAN GRILL LOAD CALCULATIONS BAJIO MEXICAN GRILL ITEM # 2 18A X 208V = 3744 7 68.7X208 X1.73= 24721 8 33.91 X 208 X 1.73 = 12202 9 11.3 X 120 = 1356 10 7.8 X 120 = 936 11 4.9 X 120 = 588 12 10.4 X 120 = 1248 13 25 X 208 = 5200 13 4 X 120 = 480 22 1 X 120 = 120 38 12 X 120 = 1440 47 5 X 120 = 600 48 12.55 X 120 = 1506 49 5 X 120 = 600 52 11 X 208 = 2288 53 4 X 120 = 480 55 .5 X 120 = 60 59 8.4 X 120 = 1008 59 8.4 X 120 = 1008 63 25 X 208 = 5200 71 2.8 X 120 = 336 72 5.6 X 120 = 672 73 5 X 120 = 600 81 7.2 X 120 = 864 RTU 28.9 X 208 X 1.73 = 10399 HOOD 20.4 X 120 = 2448 M/U AIR 20.4 X 120 = 2448 Lighting 3503 TOTAL = 86055 DIV.BY 208/1.73= 239 RECEIVED MAY 19 2010 PERMITCENTER PANEL: PANEL LA 208 VOLT 3PH 2O0A CKT USE A B C BKR CKT CKT BKR A B C CKT USE Tortilla Warmer 24721 80/3 1 2 50/3 12202 Food Steamer Tortilla Warmer 24721 80/3 3 4 50/3 12202 Food Steamer Tortilla Warmer 24721 80/3 5 6 50/3 12202 Food Steamer Washer /Dryer 5200 30/2 7 8 40/3 10399 RTU Washer /Dryer 5200 30/2 9 10 40/3 10399 RTU Walk -in cooler 5200 30/2 11 12 40/3 10399 RTU Walk -in cooler 5200 30/2 13 14 20/1 1506 Exterior Sign Hot Table 6 Well 3744 30/2 15 16 30/1 2448 Exhaust Hood Fan Hot Table 6 Well 3744 30/2 17 18 30/1 2448 Exhaust Hood Fan Dishwasher 1440 20/1 19 20 Ice Machine 2288 20/2 21 22 Ice Machine 2288 20/2 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A KVA B KVA C KVA 36561 35953 35953 24107 25049 25049 MI 2010 PERT CENTER PANEL: PANEL LB 208 VOLT 3PH 125A CKT USE A B C BKR CKT CKT BKR A B C CKT USE Exterior Sign 1506 20/1 1 2 20/1 1008 Micro -Wave Chip Warmer 1356 20/1 3 4 20/1 1008 Micro -Wave Reach -in Freezer 1248 20/1 5 6 20/1 936 Refridg Prep Table Drinks Cooler 864 20/1 7 8 20/1 600 Neon Food Sign Lg Hand Held Mixer 672 20/1 9 10 20/1 600 Neon Open Sign Refridg Prep Table 588 20/1 11 12 20/1 600 Small Hand Held mixer Music System 480 20/1 13 14 20/1 Spare Walk -in Evaporator 480 20/1 15 16 20/1 Spare Food Processor 336 20/1 17 18 20/1 180 POS System /Cash Rec Lights 1168 20/1 19 20 Lights 1168 20/1 21 22 Lights 1168 20/1 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A KVA . B KVA C KVA 4018 3676 3340 1608 1608 1716 RECEIVED MAY 19 2010 PERMIT CENTER LENNOX TM Product Submittal PROJECT INFORMATION Project Name: Baijo Grille Project Number: 3000145956 Project Location: SEATTLE, WA 00000, US Project Altitude: 1000 CUSTOMER INFORMATION Company Name: TNT Mechanical LLC Company Address: 22833 Bothell Everett Hwy, Ste. 110 Company Location: Bothell, WA 98021 -9385 Contact: Phone: 425- 486 -4327 ENGINEER INFORMATION Company Name: Company Address: Company Location: Contact: Phone: RECEIVED MAY 19 2010 PERMIT CENTER We are pleased to provide the attached project submittal. If you have any questions or need additional information, please feel free to call our office. Project #:3000145956 Quote #:4000172894 Page: 1 of 8 Project Name: Baijo Grille Quote Desc:Baijo Grille Last Changed:DAN A. GIVENS Prepared On:05/18/2010 Phone :425 - 486 -4327 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description 6-TON G /E 1' KGA072S46 .'. PKGGE/6 TON/105KB/230 -3 Project #:3000145956 Quote #:4000172894 Page: 2 of 8 Project Name:Baijo Grille Quote Desc:Baijo Grille RECEIVED MAY 19 2010 PERMIT CENTER Last Changed:DAN A. GIVENS Prepared On:05/18/2010 Phone :425 - 486 -4327 Lennox Industries Inc. - Product Submittal System 1D:6 -TON G/E Package Modet:KGA072S4B Description: PKGGE/6 TON /105KB/230 -3 HEATING PERFORMANCE Heat Source H/E HighInput H/E HighOutput System HeatOutput Natural Gas 105000 (Btuh) 84000 (Btuh) 84000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE /ThermalEff 0.50 (in.) 32.4 ( °F) 80 COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool R-410A 11.0 11.2 6300 (W) 72800 (Btuh) 70000 (Btuh) 72800 (Btuh) 69222 (Btuh) 56056 (Btuh) 52478 (Btuh) Number Compressors Condensate Drain Size Cooling OutdoorDB Cooling CondenserDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 0.75 (in.) 95.0 (°F) 95.0 (°F) 80.0 ( °F) 67.0 (°F) 57.0 ( °F) 56.9 (°F) 58.5 (°F) 57.5 ( °F) 15.8 (Ib /hr) 15.8 (lb/hr) FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type Supply Fan Type SupplyDriveReq'c{ RPM SupplyDrive Min RPM SupplyDrive Max RPM 2400 (cfm) 2400 (cfm) 0.50 (in.WC) 1.19 (hp) 2.00 (hp) CAV Belt Drive CAV Belt Drive 1233 (rpm) 968 (rpm) 1340 (rpm) TotalStaticPress Gas I-1/E Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.60 (in.WC) 0.05 (in.WC) 0.05 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequency System MCA System MOCP Compressors RLA System FLA 208V 3Ph 60 (Hz) 34.0 (amp) 50 (amp) 19.0 (amp) 28.9 (amp) SupplyFan FLA CondensingUnit FLA CondenserFan Power Unit Oper Range 7.5 (amp) 2.4 (amp) 405 (W) +/- 10% Nominal Voltage DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 47.0 (in.) 83.3 (in.) 43.4 (in.) 796 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Retum Width 18.0 (in.) 20.0 (in.) 11.0 (in.) 29.0 (in.) Project #:3000145956 Project Name:Baijo Grille Quote #:4000172894 Quote Desc:Baijo Grille Page: 3 of 8 RECEIVED MAY 19 2010 PERMIT CENTER Last Changed:DAN A. GIVENS Prepared On: 0511 8/20 1 0 Phone :425 - 486 -4327 LAMBERTSON INDUSTRIES H I G H - Q U A L I T Y S T A I N L E S S S T E E L — FloAfre* F=`E Ps!1i34 CURB / TAG: 3600 CFM # 30 - NSA12 • Descriptiun Supp Unit _4,it. Exhaust Motor Model .001580S1BA0F56 ODP (Open Drip Exhaust Motor Part Type ,,i " " *1n iie #2 Housing -40PP, 1.5 HP, 1 Phs, 115 V, 20.4 FLA, Proof) Pulleys Qty. Browning # . ' Turns Out. Belt 1 AX44 Blower Pulley 1 AK66 x 1 Motor Pulley Exhaust Performance Volume 1 1 VL40 RPM x 5/8 3.5 TS 3600 cfm 802 2520 ft/min Max Recommended RPM BHP 1500 1.247 Ambient Temperature Altitude SP ' 70° 0' 0.744' w.g. (0.500' Ext +0.2437 Int.) Construction Features • Housing constructed of heavy duty G90 g • Forward curved centrifugal blower wheel • Vibration isolation • Adjustble drive assemblies • Adjustable motor mount • Ball bearing motors • Heavy duty pre - lubricated bearings rated hours of operation • Static resistant belts • Service lid • Horizontal and down discharge • Weatherproof safety disconnect switch • 2" washable intake filters • High efficiency motors Blower • 12" forward curved, centrifugal blower. Permanently lubricated ball bearings. Galvanized finish. 1500 -5000 CFM. 1" shaft. 2140 max. RPM. Used in heated and non - heated supply fans. • OlitaH4.4" EXTERNAL SERVICE DISCONNECT' 30 GALVANIZED STEEL. 29.25. '35 ELECTRICAL DROP ++��\ CURB 32.5 13.5625 in; FLASHING 15.75 31: \� 26'.75 FILTER INTAKE.HOOD AWNING ROOF OPENING 30 deg 12 PITCHED CURBS,ARE AVAILABLE: EXAMPLE: 7/12 PITCH = '30.deg SLOPE'. 7. .BLOWER,OUTLET SIZE• "anIEWED FOR COMPLIANCE WITH'° NFPA 70 - NEC f r 200,000 JUN 012010 1.300 1.■50 • SP 1.400 0.: 50 City of Tukwila BUILDING DIVISION 7° Intake • Sloped foam filtered intake for size #2 standard untempered Make -Up Air unit with 12" blower wheel. 22" wide x 29.25" long x 31.5" high. Includes 2" Foam EZ Kleen Metal Mesh fitters. Alters • 2x EZ Kleen non -woven polyester Metal Mesh filters. 20" x 25" x 2" used for heater and supply fan intakes. 23 layers of expanded aluminum and one layer of non -woven polyester (3426). 0.250 0.000 lammain itarga....7.11M ANTATZSIIIKE111 falTiLl EMI. Miltairk 1500 2000 2500 3000 CFM 3500 4000 4500 RECEIVED MAY 19 2010 1335 ALEXANDRIA COURT SPARKS, NV 89434 LAMBERTSON INDUSTRIES, INC. PHONE 775 •857 • 1 100 TOLL -FREE 800. 548 • 3324 FAX 775 • 857 • 3289 FLOAIRE - SUPPLY - 30 PtRMITCENTER WWW.LAMBERTSON.COM SALES @LAMBERTSON.COM ElLgooe vj 10 03b11 LAMBERTSON INDUSTRIES H I G H - Q U A L I T Y S T A I N L E S S S T E E L FI * AN #17 -BDU20 ir Cad LBS. / 41 CURB / TAG: 4400 CFM - F Desc--::71; 1 Belt Dnve Centrifu FXhai:;:;l Vlo'ior Mtodel 001580S1BA0F56 ODP (Open Drip Exhaust Motor Part Type • •4.1 -14% . ust Fan with 20.75" Wheel -40PP, 1.5 HP, 1 Phs, 115 V, 20.4 FLA, Proof) Pulleys Qty, Browning # Turns Out Belt , - 1 AX25 Blower Pulley 1 AK54 x 3/4 Motor Pulley Exhaust Performance Volume 1 1 VL40 RPM x 5/8 3.5 TS 4400 cfm 974 5291 ft/min Max Recommended RPM BHP :. -•- • 900 1.19 RE Ambient Temperature Attitude SP .� 70° 0' 0.75" w., -llr I Construction Features • Housing constructed of heavy gauge alumi • Centrifugal backward inclined, non - overloading wheel, built out of 3003 -H14 aluminum • Weatherproof safety disconnect switch • Grease spout welded to housing • Vibration isolators • Adjustble pitch drive assemblies • Adjustable motor mount • Ball bearing motors • Forces fresh air through motor to ensure long motor life • Corrosion resistant fasteners • Thermal overload protection • High heat operation (300 °F) • Rated for restaurant and general ventilation applications • Grease classification tested 33.375 LIANCE WI A 70 -N -.26 deg 12 um JUN 01 d �,� PLE CURBS 7:12 P ED City of Tukwila BUILDING DIVISI Selected Options • GREASE CUP - Grease Cup for kitchen -duty centrifugal exhaut fans, Box Dimensions: 15 -3/4 L x 5 -1/16 W x 3 -3/4 H (18 GA.) 5P /26 y . ROOF OPENING 24 ' E AVAILABLE 24 CH = 30.26 deg SLOPE 2.250 2.000 1.750 1.500 1.250 1.000 0.750 0.500 0.250 0.000 1700 2200 I700 3200 3700 4200 4700 5200 5700 6200 6700 CFM 1335 ALEXANDRIA COURT SPARKS, NV 89434 LAMBERTSON INDUSTRIES, INC. PHONE 775 • 857 • 1 100 SALES @LAMBERTSON.COM TOLL -FREE 800 • 548. 33 ECEIV • 857 329 F LOAIRE 35 LINED spy �J MAY 19 2010 PERIATCENTER WWW.LAMBERTSON.COM LlO Q3(l rnI 1 Ni 1700 2200 I700 3200 3700 4200 4700 5200 5700 6200 6700 CFM 1335 ALEXANDRIA COURT SPARKS, NV 89434 LAMBERTSON INDUSTRIES, INC. PHONE 775 • 857 • 1 100 SALES @LAMBERTSON.COM TOLL -FREE 800 • 548. 33 ECEIV • 857 329 F LOAIRE 35 LINED spy �J MAY 19 2010 PERIATCENTER WWW.LAMBERTSON.COM LlO Q3(l rnI • PE'i CUM PLAN REVIEW /R • ING SLIP ACTIVITY NUMBER: EL10 -0364 0 DATE: 05 -19 -10 PROJECT NAME: BAJIO MEXICAN GRILL SITE ADDRESS: 7100 FUN CENTER WY - SUITE 140 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENT OW( # Building Division Public Works ❑ Fire Prevention Structural n Planning Division Fl ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 17(1 Incomplete DUE DATE: 05 -20 -10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -17 -10 Approved' ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center,Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Prfker Friendly Page • Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company Oti Services Inc 3604582927 Po Box 982 Mckenna Wa 98558 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602662140 Active OTISESI940Q1 Electrical Contractor 11/21/2006 11/21/2010 General Unused sociated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status OTISEED986K9 Oti Services Elect Division Electrical Contractor General Unused 5/29/2002 5/29/2008 Expired MASTER ELECTRICIAN INFORMATION License BEDNAMJ968MN Name Bednar, Mark J Status Active Business Owner Information Name Role Effective Date Expiration Date Unisearch Inc Agent 11/21/2006 5/12/2009 Ottwell, Ramona J President 11/21/2006 $1,000.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 INSCO INSURANCE SERVICES INC 857805C 11/20/2006 Until Cancelled $4,000.00 11/21/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBOES00381 5/12/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 https: // fortress .wa.gov /lni /bbip /Print.aspx 07/02/2010 ai 0 a) 0 CO 0 a) 0 0 0 U) On c 0 0 0 0 0 V) 0 4920 REGISTERED ARCHITECT MICHAEL C. RAYMOND STATE OF WASHINGTON z CD X L,J 0 m L.LI 1— z L_LJ U L.L Q n z 0 DRAWN W Cr) I w w CI) LLI LLI U LLI N N) CHECKED CD CO 00 1 Q 0 DATE 03/17/2010 SCALE JOB NO. 10 -10 SHEET NO. Al 01 Tukwila, Washington II 1. EXISTING WATER HEATER PROVIDE WALL -HUNG CABINET PROVIDE WALL -HUNG -} ABOVE RESTROOMS w /LOCK. SELECTION BY OWNER CABINET. SELECTION I UPGRADE AS NEEDED BY OWNER BUILT IN COUNTER @ 30" A.F.F. 0 %iiiiiii_i REVIEWED FOR COMPLIANCE WITH ® JUN o 1 2010 City /iiiiiiiiiiiiii / iiiiiiiiiiiiiiiiiiiiiiiii // /iiiiiiiiiiiiiiii Ayice /iiii iiiiiiiiiiiiiiiiiiiiiiiiiii /iiiiiiiiiiiiiiii 0 REF: A102 0 G / / �I 4/ /1 / / 1 / / 1 0 G / 04 6 / 32 32 • ` - 1 # 0 / / MIMMENEWMUN II / / i� li � �■ ■ ■ I I I( 18 _ , \ � s 1 \ I 53 - OFFICE a I { 18 • �; i 18 1 I (i E1 r 'lIli 8 / 42 . - �CISTING MEN �, , � � / 106 ;a �I � I $o —� EXISTING 0 ® ,il! = III =,�w I � 13 6-0"x 9 ° \ 104 _ �i -� - ; _- - 18�� 1,� �: 18 .__ ; " 11 I - ' - e' • % '• - `�` WOMEN'S �.,, �. �,$ bli !J! 1 0 / 0 / Jo G _ 18;1 arm.. �� FD � e ' �'' (ABOVE) REAR SERVICE AREA N— FD ® zw4wiii / �G i/ EXISTING ELECTRICAL UPGRADE AS PANEL NEEDED I9- 1 102 0 ukwria I''' `71 ='�.�� I �+ i�„ C�DEC�MP�IA l:.ION 111 AAA, • FS � ' (ABOVE) nal 0�C i u i I. �l.1 111 SPACE FOR -,.;.� - ��` ,..,, —' 0 _-_�:r HIGH CHAIRS � '18' hdi 18 ���� �v 184 0 // f / L - , , _ �1, �- CLEAR AREA FS - 0 r FLOOR ( BOOR SPACE L (5- J CUSTOMER 4:1) ® SS CORNER FD FD GUARDS (ON SHELF TYP. ABOVE) ! r, IL ,1 • U iI . III. ^p� I Il ly 100 (ABOVE) 21 FS 0 (ABOVE) ./ _, I , (- ,_ All - -I 0 ----1'cl °."' °�% �4� / / Col 22 / / SPACE FOR DIRTY GARBAGE CAN DIRTY SIDE SIDE 0 m ID, �e, - HAMMERED RAIL .„ / / / / / / /iI"` %///////////////////// ��// / / / / / / / / / / / // /// / / / / /�i� / / / / /// 2O 0 42 ' \ ` ' ' , , / // , 0 , (ABOVE) \\ , \\ /, `, RT `\ THIS NOT A PROPAJECT OF /' ,' / v \ /' \ / , / \ , / / itie ii,---) �D�o �- 00 (PO) 1 /I / / / G �/ / 0 D G T PIM midi isa„,.. FRONT S�RVIC AREA am DECORATIVE PLANTS WATER el. r 1 r I 64 0 (ABOVE) III ` 1 5y) �' 5 {) <� I 101 FS - 0 / el / % i/ / 0 r` 1 /, 0 / G 0 — \ ,r /,I id \ 0 4s �. SEPARATE PERMIT REQUIRED FOR: Mechani FEATURE \ II ,\, D ( t!) O \' ® ' \ \ ,.. Fix AL.1-- ;?T;ang City of Tukwila BOLDING DIVISION , — = 17 o ,� v, ,' \\ / \ r i '� `\ n review a rov • Pia pP ,/' ` \\ approve! of construe /' `\ ti'�e violation of any ,' `\ ai approved Field C / \ // `\ Date: /''' \``\ \ \ ,, \\ \ , .,, ell *Ili\ ABOVE is s nbiect to errors and omissions. on documents does not authorize opted code or ardinance. Receipt N an conditions is acknawledgede y ! • Of Tukwila LDING DIVISION. ® y �_.. i, C � REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitt ! and may include additional plan review fees. O x : . 4- 32 � o .� 2$ - a4 IA 4 \ ` / IV 32 /'' \\ ' \ ' ` I MAY 192010 PERMIT CENTER r' 36 1 1 �\ 1 78 I En \ ,/' \\ 0 .0 =_ '////// /// / / / / / / / / / //% / /Alw p m. A Y1 �?�, Fl 0 0 4.111P- 0 (2) 48 47 EQUIPMENT & FURNITURE ' Llllld � O3F4` PLAN W S NORTH lb ___ __ _ _ _ _ SCALE 1 /4" = 1' -0" SEATING SHOWN FOR 49 4920 REGISTERED ARCHITECT MICHAEL C. RAYMOND STATE OF WASHINGTON z CD X L,J 0 m L.LI 1— z L_LJ U L.L Q n z 0 DRAWN W Cr) I w w CI) LLI LLI U LLI N N) CHECKED CD CO 00 1 Q 0 DATE 03/17/2010 SCALE JOB NO. 10 -10 SHEET NO. Al 01 Tukwila, Washington 3/17/2010 10:33:15 AM K: \Drawings2010 \Bajio Seattle \BajioSeattle.rvt T SCHEDULE FURNITURE & EQUIPMENT F FURNITURE & EQUIPMENT SCHEDULE (CONTINUED) VENDOR CONTACTS REVISIONS DALE_ _ _: ITEM NO ITEM QTY MANUFACT. DESCRIPTION GAS HOT H2O COLD H2O FILTERED H2O VENT WASTE INDIRECT WASTE VOLTAGE/ PHASE AMPS NEMA PLUG SUPPLIED BY ORDERED BY INSTALLED BY ITEM NO ITEM QTY MANUFACT. DESCRIPTION GAS NOT H2O COLD H2O FILTERED H2O VENT WASTE INDIRECT WASTE VOLTAGE/ PHASE AMPS NEMA PLUG SUPPLIED BY ORDERED BY INSTALLED BY COMMERCIAL KITCHEN SUPPLY KEITH EUBANK ENCEN ERVT LE NORTH TERVILLE, UT 84014 PHONE: 801-292-1611, EXT. 101 FAX: 801- 292 -9797 WASATCH ARTISAN WOODWORKS Z\ 1 FRYER 1 DEAN MODEL: SR52; 50 LB. w /SIDE SHIELDS & CASTERS 3/4" NPT CKS BAJIQ NATIONAL G.C. 70 TOILET PAPER HOLDER DBL. ROLL BOBRICK (OR EQUAL) MODEL: 8 -2746 OR EQUAL SYSCO G.C. G.C. NOTE 14 2 HOT TABLE 6 WELL 1 VOLLRATH MODEL: �LLING FAUCET DROP -IN 3/8" 1 1/2" 1 1!2" 1 PH 18A 6 -30P CKS BAJIQ NATIONAL NOTE 1 71 FOOD PROCESSOR 1 GLOBE PROVIDE ACCESSORY GFP500; 1!2 HP, 5 115V/60 1PH 2 8A 5 -15P CKS BAJIQ NATIONAL NOTE 1 3 4 ICE BIN CHARBROILER & S.S. STAND w /CASTERS 1 1 - AMERICAN RANGE MODEL: ARRB-48; BTU; NOTE #5; STAND MODEL: EAGLE T3048GS 3/4" NPT CKS CKS BAJIQ NATIONAL BAJIQ NATIONAL NOTE 1 NOTE 1 72 LG. HAND HELD MIXER 1 ROBOT COUPE MODEL: MP 450; 650W 120V/60 1PH 5.6A 5 -15P CKS BAJIQ NATIONAL NOTE 1 RD WOOD 90 NORTH DRAPER LANE PROVO, UT 84601 PHONE: 801 - 377 -0496 VILLA LIGHTING SUPPLY 73 SM. HAND HELD MIXER BEVERAGE CENTER 1 1 WARING COMMERCIAL MODEL: WSB33 QUIK STIK IMMERSION BLENDER 100 W .. _„ MILLWORK _.., _... 120V/60 1 PH 5 15P vm CKS MILLWORK BAJIQ NATIONAL NOTE 1 G.C. NOTE 1 5 6 BURNER RANGE w/ STD. OVEN &CASTERS 2 AMERICAN RANGE ER AMERICAN MODEL AR 6; 227,000 BTU, MODE L5 (1"} 3/4" 34" CKS BAJIQ NATIONAL NOTE 1 74 BAJIQ NATIONAL 6 CHEESE MELTER/BROILER 1 AMERICAN RANGE MODEL: ARCM -60; 55,000 BTU 3/4" NPT CKS BAJIQ NATIONAL NOTE 1,14 75 WATER FILTER 1 CUNO MODEL: SW3 -PLUS; MOUNT ON WALL (NOTE 6) 1/2" NPT COKE G.G. G.C. / (REF. SHEET A102) USA TELDATA BRYAN NASH MOBILE: 801- 918 -0755 PHONE: 801-484-0155 bryan @usateldata.com CONTRACT FURNITURE COMPANY 7 TORTILLA WARMER 1 VULCAN MODEL: HEG48D GRIDDLE, 21.6 kW; STAND MODEL: EAGLE T3048GS 208V/60 3PH ss.7A CKS BAJIQ NATIONAL NOTE 1 76 SPLASH GUARD 2 BRADLEY (OR EQUAL) MODEL: #5; DEEP, w /WALL MOUNTED S.S. GSA BRACKET G.C. G.C. G.C. NOTE 14 4920 REGISTERED ARCHITECT MICHAEL C. RAYMOND STATE OF WASHINGTON 8 FOOD STEAMER w/ CUSTOM S.S. STAND 1 ACCUTEMP MODEL: 208D12 -000, 12kW 208V 3PH 33.91A 15 50P CKS BAJIQ NATIONAL NOTE 1 77 DECORATIVE MIRROR TO BE SELECTED BY OWNER G.C. G.C. G.C. 8a HOT FOOD BOX 1 CKS BAJIQ NATIONAL NOTE 1 78 MARIACHI MUSICIAN 1 BAJIQ METAL STATUE BOLT TO FLOOR BAJIQ BAJIQ NATIONAL G.C. NOTE 12 9 CHIP WARMER (3) DRAWER 1 APW WYOTT APW HDD -3, 1350 W 120V 11.3A 5 -15P CKS BAJIQ NATIONAL NOTE 1 HAND DRYER 2 EXCEL XLERATOR MODEL XL -GR 12 Z 7 SYSCO G.C. G.C. NOTE 14 10 REFRIG. PREP TABLE 1 TRUE MODEL: TSSU 60 24M B -ST; 1/3 HP, 24 PAN 115V/60 1 PH 7.8A 5 -15P CKS BAJIQ NATIONAL NOTE 1 80 BABY CHANGING STATION 1 KOALA KARE MODEL K6100-00 INSTALL PER MANUF. INSTRUCTIONS CKS BAJIQ NATIONAL NOTE 1, 14 PROFESSIONAL GRADE FURNITURE 1874 SOUTH PACIFIC COAST HWY #377 REDONDO BEACH, CA 90277 PHONE: 310 -544 -2382 FAX: 310-544-2387 www. C o n tract F u rn i to re . co m SIGN GUYS 11 REFRIG. PREP TABLE TRUE MODEL TSSU 27- 12M -B, 1/5 HP, 12 PAN 115V/60 1 PH 4.9A 5-15P CKS BAJIQ NATIONAL NOTE 1 81 DRINKS COOLER 1 TRUE MODEL GDM -26 w /CocaCola LOGO 120V/60 1 PH 7.2A 5-15P COKE G.C. COKE 12 REACH -IN FREEZER 1 TRUE MODEL: T -23F 115V/60 1 PH 10.4A 515P CKS BAJIQ NATIONAL NOTE 1 13 WALK-IN COOLER BOX 1 KOOL STAR COVED BASOE, FLASHING (2) LIGHTS CKS NATIONAL G.C. NOTES BAJIO MEXICAN GRILL AT FAMILY FUN CENTER 7100 Fun Center Way #140 Tukwila, Washington WALDEN ING UNIT CONDENSING UNIT 1 KOOL STAR C.U. MODEL: MMODEL: C; 1.5 H.P. COMPRESSOR MODEL: CR18KQ -PFV 20 H 1 PH CKS BAJIQ NATIONAL G.C. 1. EQUIPMENT RECEIVED AND SET IN PLACE BY CKS, IF HIRED TO INSTALL. FINAL CONNECTIONS BY PLUMBER AND ELECTRICIAN. 2. RESTROOM FIXTURES AND ACCESSORIES BY GENERAL CONTRACTOR. 3. EQUIPMENT CORD AND PLUG SPECIFICATIONS - FIELD VERIFY BY GENERAL CONTRACTOR. 4. NOT ALL EQUIPMENT IN SCHEDULE MAY BE USED. 5. PROVIDE DORMONT GAS CONNECTOR: BASIC KIT, 3/4 ", 48" LENGTH - 1675BPQR48. 6. WATER FILTRATION SYSTEM IS REQUIRED IN ALL STORES THAT DISPENSE BEVERAGES. 1/2 " INCOMING WATER LINE FEED WITH 1/2" BALL VALVE SHUTOFF. MINIMUM 110V, 20A DEDICATED ELECTRICAL SERVICE TO SUPPORT CARBONATOR AND WATER BOOSTER. CONFIRM WITH MANUFACTURER. 7. ATTACH S.S. BACKSPLASH TO WALL WITH S.S. SCREWS INTO METAL STUDS, SEAL WITH CONTINUOUS BEAD OF NSF APPROVED CLEAR SILICONE. 8. MOUNT TABLE LEGS SUCH THAT CLEAR FLOOR AREA OF 30" IS PROVIDED TO MEET ACCESSIBILITY GUIDELINES. 9. BUILDING SIGNAGE TO BE PERMITTED UNDER SEPARATE CONTRACT. COORDINATE QUANTITY, SIZE & FINAL LOCATION OF BUILDING SIGNS w /SIGNAGE PERMIT. 10. G.C. TO INSTALL METAL MOUNTING FLANGE PROVIDED BY CKS ON TOP OF SODA MACHINE & SET ICE MACHINE ON FLANGE. 11. ATTACH WALL SHELVING w /ANCHORS INTO METAL STUDS OR PROVIDE SOLID BLOCKING; MOUNT @ 5' -0" A.F.F.; 6' -8" A.F.F. IF OVER WIRE SHELVING, U.N.O. 12. ANCHOR MARIACHI FIGURE TO FLOOR w /(2) 3/8" DIA. x 3 3/4" LONG EXPANSION ANCHORS (1) IN EACH FOOT OF STATUE. 13. ANCHOR BAR HEIGHT TABLE BASES TO FLOOR w /(4) 3/8" DIA. x 3 3/4" LONG EXPANSION ANCHORS, TYPICAL. 14. PROVIDE SOLID BLOCKING IN WALL FOR ALL WALL -HUNG EQUIPMENT. 15. CONTACT BRYAN NASH AT USA TELDATA FOR INSTALLATION INSTRUCTIONS FOR POS AND COMMUNICATION CABINET. ETHAN MOON PHONE: 801 368 -6355 ethan @thesignguys.org WALK -IN COOLER EVAPORATOR COIL 1 KOOL STAR MODEL: E1 HX0130A; REQUIRES CU CONDENSATE DRAIN 115V/60 1 PH CKS BAJIQ NATIONAL G.C. 14 POT FILLER (OPTIONAL) - T & S MODEL: B -0600 1/2" PLUMBER CKS = COMMERCIAL KITCHEN SUPPLY ELEC. = ELECTRICAL CONTRACTOR BAJIQ = FRANCHISER G.C. = GENERAL CONTRACTOR MILLWORK = WASATCH ARTISAN WOODWORKS V = VARIES MILLWORK = MILLWORK CONTRACTOR CFC = CONTRACT FURNITURE COMPANY 15 2 COMPARTMENT VEGGIE SINK w /FAUCET 1 EAGLE MODEL: 412- 16 -2 -18, FAUCET KROWNE 14 -182 1/2" 1/2" 1 1/2' 1 1/2" CKS BAJIQ NATIONAL PLUMBER NOTE 7 16 3 COMPART. SINK w /(2) FAUCETS, PRE RINSE 1 EAGLE MODEL: 414 -18 -3-18; 24x18 BOWLS, FAUCET: KROWNE 17- 108W/21 -141 (2)1/2" (2)1/2" 1 1/2" 1 1/2" CKS BAJIQ NATIONAL PLUMBER NOTE 7 17 TYPE I EXHAUST HOOD w /PSP MAKE-UP AIR 1 CAPTIVE AIRE REF. CA SHEETS CKS BAJIQ NATIONAL G.C. 18 S.S. WIRE SHELVING V INTERMETRO SUPER ERECTA SHELF; SIZE & QUANTITIES BY ORDERER CKS BAJIQ NATIONAL NOTE 1 TED PREP TABLE (OPTIONA TRUE MODEL: TSSU- 48- 18M -B; 1/3 HP, 18 PAN 115 0 PH 8. 5 CKS BAJIQ NATIONAL NOTE 1 20 S.S. PREP TABLE 2 EAGLE MODEL: (2) T3048B, (1) T3024B & (1) T30306 w /DRAWERS 50072 CKS BAJIQ NATIONAL NOTE 1 21 S.S. WALL SHELVING V INTROMETRO (OR EQUAL) CKS BAJIQ NATIONAL NOTE 1, 11 22 P.O.S. SYSTEM 1 5 -15P TELDATA BAJIQ NATIONAL G.C. NOTE 15 REVIEWED CODE COMPLIANCE APPPrIVED JUN O 1 21110 23 MOP SINK 1 STERN WILLIAMS SERVICEPTOR SB -800 24x24x12 w /FAUCETT- 10 -VB, T -35, T-40, BP 3/4" 3/4" 2" 3" PLUMBER PLUMBER PLUMBER 24 DRYING RACK - COORDINATE SELECTION w /OWNER G.C. G.C. G.C., NOTE 11 25 WATER HEATER - REF: PLUMBING PLUMBER G.C. PLUMBER 26 MILLWORK CABINETS V BAJIQ BAJIQ NATIONAL G' G' 27 CIRCULAR, BAR HEIGHT DINING TABLES (30" DIA.) 4 USE BASE MODEL #4416 -3L5 BAJIQ BAJIQ NATIONAL NOTE 1, 13 t ' u �^1 BUILDING' 1'ii" �I 28 CIRCULAR DINING TABLES (42" DIA.) 1 USE BASE MODEL #C1- 30R -4L5 BAJIQ BAJIQ NATIONAL NOTE 1 29 OUTDOOR DINING TABLES (32 "x32 ") - EMU CAMBI DINING TABLE 4/801 CFC G.C. G.C. ,-` ELI C IVY ►'i =.'`9 19 2010 PERMIT SENT CENTER 29a OUTDOOR DINING TABLE (ADA) - CFC G.C. G.C., NOTE 8 30 DINING TABLE (27 "x27 ") 4 USE BASE MODEL #CI -22-44 PC BAJIQ BAJIQ NOTE 1 31 OUTDOOR DINING CHAIR - EMU SEGNO ARM CHAIR #268 CFC G.C. G.C. 32 DINING TABLE (36 "x36 ") 4 USE BASE MODEL #CI -30-4 PC BAJIQ BAJIQ NOTE 1 33 DINING CHAIR 37 BAJIQ BAJIQ NOTE 1 34 BAR HEIGHT DINING CHAIR 12 BAJIQ BAJIQ NOTE 1 MIC -AL RAYVOND, ARC -ITPCT 35 ADA DINING TABLE (33 "x46 ") 2 USE (2) BASE MODEL #1502 -2LS PC 30" MIN. CLEAR BETWEEN BAJIQ BAJIQ NOTE 1, 8 36 TRASH RECEPTACLE (DOUBLE) 1 MILLWORK BAJIQ NATIONAL NOTE 1 37 WALL ART 48 "x72" 2 BAJIQ BAJIQ G.C. 38 DISHWASHER w /CONDENSATE HOOD (OPTIONAL) 1 PURITAN MODEL: PA -1, 68 GPH, 2/4 HP WASH PUMP, 140 DEG RECMND. 3/4" 1 1/2" 2" 115V/60 1 PH 12.0A OWNER OWNER G.C. 39 MENU BOARD 1 BAJIQ BAJIQ G.C. 40 FRONT COUNTER 1 MILLWORK MILLWORK BAJIQ NATIONAL G.C. 41 S.S. HAND SINK 3 KROWNE MODEL: HS -5; WALL MOUNTED w/H -107 TWO SIDE SPLASHES 1/2" 1/2" 1 1/2" CKS BAJIQ NATIONAL PLUMBER NOTE 14 42 SOAP DISPENSER 5 FOOD VENDOR G.C. G.C. NOTE 14 43 PAPER TOWEL DISPENSER 3 FOOD VENDOR G C G.C. NOTE 14 44 FIRE EXTINGUISHER TYPE K 1 BADGER (OR EQUAL) MODEL: WC -250 BADGER (OR EQUAL) G.C. G.C. NOTE 14 45 FIRE EXTINGUISHER TYPE ABC 1 BADGER (OR EQUAL) MODEL: 10 -MB 8H BADGER (OR EQUAL) G.C. , G.C. NOTE 14 46 S.S. WALL CLADDING V ON WALL BELOW HOOD; REF: A300 FOR SIZE G.C. G.C. G.C. 47 NEON SIGN "MEXICAN FOOD" 1 LOCATE IN WINDOW; PROVIDE RECEPTACLE ABOVE WINDOW SIGN GUYS BAJIQ NATIONAL G.C. 48 EXTERIOR BUILDING SIGN 1 (1) DEDICATED 20A CIRCUIT PER SIGN, FIELD VERIFY LOCATION 120V 12.55A SIGN GUYS BAJIQ NATIONAL G.C. NOTE 9 49 NEON SIGN "OPEN" 1 LOCATE IN WINDOW; PROVIDE RECEPTACLE ABOVE WINDOW SIGN GUYS BAJIQ NATIONAL G.C. 50 SODA FOUNTAIN MACHINE 1 CORNELIUS ENDURO250 1/2" 3/4" COKE G.C. 1 NOOTE TE 10 51 52 SODA BAG -IN -BOX RACK ICE MACHINE 1 1 COKE FOLLETT 1/2" 3/8" 208V/60 1 PH 11A 6 -15P COKE CKS G.C. BAJIQ NATIONAL COKE NOTE 1, 10 HORIZON CHEWBLETHCC1o00AHT; LOCATE ON SODA FOUNTAIN TOP 3/4" MPT 53 MUSIC SYSTEM 1 SPEAKER CLR TO MATCH CEILING CLR ENCOMPASS LE /PASO DMA 2060 120V/117V 60Hz 1PH 4/3.45A 5 -15P G.C. G.C. 54 TREE POTS 2 BAJIQ NATIONAL G.C. 55 COMMUNICATIONS CABINET 1 MOUNT RECESSED w /BOTTOM OF CABINET @ 42" A.F.F. TELDATA G.C. G.C. NOTE 15 56 POT RACK 1 STAINED; SUSPENDED BY ANTIQUED CHAIN BAJIQ NATIONAL BAJIQ NATIONAL G.C. 57 BULK CO2 TANK 1 NUCO2 LOCATE ABOVE WALK -IN COOLER UNLESS SHOWN OTHERWISE NUCO2 G.C. G.C. // ` 58 BARREL 2 BAJIQ BAJIQ NATIONAL G.C. DRAWN 59 MICROWAVE 2 AMANA MODEL: HDC12A,1200W; ON SHELF ABOVE PREP TABLE 120V/60 1 PH 16.8A 5 -20P CKS BAJIQ NOTE 1 60 WALL POTS 2 BAJIQ BAJIQ NATIONAL G.C. NOTE 14 CHECKED 61 GRAB BAR 18" MOUNTED VERTICAL BOBRICK (OR EQUAL) MODEL: 86806.99,1 1/2" DIA. x 18 "; CONCEALED MNT; PEENED G.C. G.C. G.C. NOTE 14 DATE 03/17/2010 62 DROP SAFE 1 CSS MODEL: CS2820 CKS BAJIQ NATIONAL G.C. SCALE 63 64 STACKED WASHER/DRYER PLANTS 1 5 G.C. G.C. G.C. JOB NO. 10 — 1 0 PROVIDE 48" HIGH S.S. CORNER OUTSIDE CORNERS FULL END WRAP GUARDS AT ALL END OF WALL CONDITIONS, TYPICAL ALL SERVICE AREAS. SHEET NO. A 101 a HOT TABLE 3 WEL OPTIONAL - VOLLRATH MODEL: 38103; 2100W 1 '' 1' 7 5 // CKS BAJIQ NATIONAL NOTE 1 66 CAN RACK FOR #10 CANS 1 NEW AGE INDUSTRIAL MODEL 1250 CKS BAJIQ NATIONAL NOTE 1 67 WALL ART 72 "x48" 1 BAJIQ NATIONAL NOTE 1 68 69 GRAB BAR 36" GRAB BAR 48" - BOBRICK (OR EQUAL) BOBRICK (OR EQUAL) MODEL: B6806.99, 1 1/2" DIA. x 36'; CONCEALED MNT; PEENED MODEL: B6806.99, 1 1/2" DIA. x 48 "; CONCEALED MNT; PEENED G.C. G.C. G.C. G.C. G.C. NOTE 14 G.C. NOTE 14 . MICHAEL C. RAYMOND STATE OF WASHINGTON DRAWN CHECKED DATE 03/17/2010 SCALE JOB NO. 10 -10 SHEET NO. LIGHT FIXTURE SCHEDULE ,4 REMARKS MOUNTING VOLTS LAMPS CATALOG NUMBER MANUFACTURER DESCRIPTION QUANTITY TYPE NO. NOTES TYPE SYMBOL 2x4 RECESSED I �j � � " JUN a 1 ° � 1 ' RECESSED 120 F32T8/XL/SP35/WM/ECO #48522 3 MX- 2GR8 -332A- UNV- AD- IOP3P32SC -U METALUX L1 % % %�j 010 11 GE 72 VA %/!�.//// l/ fll l! /!!.//// / / / / % / / /!./!J/ 1x4 FLUORESCENT VAPORTIGHT FLUORESCENT :13:118' $` S 1 "� 1 . I it 9 / � � O � r/ � ��1 � O 0 l O � �j/ r II/, / � / I ��I// 4 IOC 4 EXISTING GYP LIN CEILING C5 � � 1000 /� EXISTING GYP BD CEILING C5 ,, OPEN TO STRUCTURE ABOVE COOLER �9 � /�� SURFACE 120 F32T8/XL/SP35/WM /ECO 2 VT2-2- 32 -DR- UNV- EB8I -WL METALUX Li A 6" COMPACT FLUORESCENT #48522 �/ � G �,� L1 o 1 GE 1 E O 0 z ¢ J DOWNLIGHT L6 g g L4 L4 48 VA id' - 0" RECESSED 120 F32TBX/835 /A/ECO 1 PL642EU /239 -WH JUNO L2 0 #97631 PROVIDE CLEAR ALZAK LENS CI 12 GE 36 VA i L4A A200 LOW VOLTAGE TRACK HEAD TRACK MOUNT 120 035MR16/C/SP20/10PK 1 T442BL/T538BL JUNG L3 L12 Li WA #00256 PROVIDE SHATTERPROOF LENS WHEN USED OVER FOOD NOTE 1 11 GE 35 VA L7 ] E L4 L4 L12 MONO POINT TRACK HEAD MOUNT ON J -BOX 10' -0" O.C. PENDANT 120 45PAR3OHIR/FL25XL 1 R532BL/T4OBL JUNG L4 EXISTING ibiL2 6 10' -0" A.F.F. #41547 POINT ALL LAMPS ABOVE TABLES DOWN GYP BD CEILING NOTE 2 19 GE 45 VA % L5 C5 L5 0I �T L12 ) Li L1 _ MONO POINT TRACK HEAD MOUNT ON J -BOX 00 1d' 0" O.C. PENDANT 120 45PAR3OHIR/FL25XL 1 R532BL/T4OBL JUNG � 10' -0" A.F.F. #41547 AIM FIXTURES AT GRAPHICS, SIGNAGE, MENU BOARDS, TALAVERA AND BEVERAGE AREA L4A NOTE 2 12 GE t� ��y➢ / � 45 VA 6 10' - 0" SUSPENDED LIGHT FIXTURE "A" L12 PENDANT 120 FLE2OHT3/2/827 FIXTURE BY OWNER L5 L6 `~ L4A L4A A200 #15834 MOUNTING HEIGHT VARIES; REFERENCE LIGHTING GENERAL NOTES E & F L1 _- ....... Li 2 GE g g LL41 `� �- 23 VA SUSPENDED LIGHT FIXTURE "B" Li i L4 L4 L8 , 14 O 6� A200 PENDANT 120 FLE2OHT3/2/827 1 FIXTURE BY OWNER L6 L6 #15834 MOUNTING HEIGHT VARIES; REFERENCE LIGHTING GENERAL NOTES E & F �, ` , 23 VA 8 GE _ Q � ���— %MOUNTING _�_ SUSPENDED LIGHT FIXTURE "C L12 10' - 0" L7 p� kY Li �� L8 ) PENDANT 120 FLE2OHT3/2/827 1 FIXTURE BYOWNER L7 t LR #15834 HEIGHT VARIES; REFERENCE LIGHTING GENERAL NOTES E & F 6 GE L2 Q L2 Q A L12��/ 111 / /, // Y/// i//J//f / / / / 23 VA � f ` \\` /, `\ 0 EXIT & EMERGENCY LIGH ING COMBO L4 L4 ` WALL 120 6V5.4W 2 VEX- U- P- WB- WH -EL27M EXITRONIX L8 t4 A200 MOUNT ON WALL @ 12' -0" A.F.F. (ABOVE TALAVERA) UNLESS NOTED OTHERWISE 3 f' 4 MP; �— C6 �, ' ,` ` `\ 11 \\ ,` \ , 13 VA REMOTE EXIT & EMERGENCY LIGHT WALL 120 6V 5.4W / 6V 6W 2 W/ TR R BR EXITRONIX LR WALL LIGHT (C.F.C.I.) PROVIDE REMOTE HEAD ON EXTERIOR OF BUILDING ABOVE EACH ENTRANCE /EXIT DOOR / djl' 2 WALL 1'� II L2 Q ��% 7' -0" A.F.F. U.N.O. 120 F32T8/XL/SP35/WM /ECO 2 x it', 4' FLUORESCENT UP /DOWN STAINLESS STEEL EXHAUST HOOD REF: CAPTIVE AIRS DRAWINGS ♦ A . A200 O �/ % OA AN \ ,' \ \\ /,' \ ,` `\ /� \ � '\ / ` �\ �` ' NOT A PART OF \\ THIS PROJECT ,' \ , �` /� '\ ,` `\ 1/ , MP65 232- OCT- ASW- ELB -UNI MERCURY L9 L4 L4 L4A I0I ' V #48522 RED LED EXIT n� 1 1 NOTE 3 0 GE L7 - EXPOSED STRUCTURE PAINT P13 ■��• C7 L4A �,4 48 VA 12 Q SIGN w /90 MINUTE BATTERY BACKUP A i i I' 7-0" A.F.F. U.N.O. WALL 120/277 RED LED 6 VEX- U- P -WB -WH EXITRONIX LI O 12 VA d/ �• ° � 19 �) I L2 Q RED LED EXIT SIGN w /90 MINUTE BATTERY BACKUP CENTER OF J -BOX @ 8' -9" A.F.F. U.N.O. WALL 120 FLE2OHT3/2/827 1 P5704 -30 PROGRESS Li 1 L4 L4A 1 #15834 GE SURFACE MOUNT WITH SHROUD AT WALL MOUNT LOCATIONS; SHROUD (OWNER FURNISHED, CONTRACTOR INSTALLED) �(I �4,6'4 23 VA 1ii L2 Q ` \ / l`\ EMERGENCY LIGHT L6 WALL 120/277 6V 5.4W HALOGEN 2 LL5OH EXITRONIX MOUNT ON CEILING IN BACKROOM WHERE SHOWN;; �, / \ ' • ` ' i G ��' ►�s, 7 MOUNT ON WALL @ 12-0" A.F.F. (CUSTOMER AREA), L12 _ L4 L3 L3 8'1 ° 13 VA 9' -O" A.F.F. (SERVICE AREAS) U.N.O. NOTES 1. PROVIDE JUNG TRACK #T4BL, T8BL, T34BL & T23BL. 2. MOUNT FIXTURE TO OUTLET BOX IN CEILING, PAINT BLACK; REF. PLAN1 -A102 FOR MOUNTING HEIGHTS OTHEN THAN 10' -0" 3, LAVATORY VENTILATION PROVIDED BY GENERAL CONTRACTOR; REF: MECHANICAL. \ \ 0 L4 tf,A L4A L2 O ,` .� 1' `\ �� ,` \`\ L7 A SUSPENDED POT RACK„' LIGHTING GENERAL NOTES L12 �� � / / NOTE G. POSITION f/ \\ HANGING POTS SFrION H, , THAT THEY DO NOT ii \\ INTERFERE WITH / LIGHTING. , , \ ,,` \,, ,` ' ` ' , '� �` ,` \ \ ` ` / \ ' \ 1' �\ A. ALL LIGHTING TO BE ORDERED BYOWNER THROUGH VILLA LIGHTING SUPPLY; TOM RIST 1218 SOUTH VANDEVENTER AVENUE SAINT LOUIS, MO 63110 PHONE (314) 633 -0451, FAX (314) 633 -0451 CONTACT BAJIO COORDINATOR @ 801- 655 -5040 X 2230 FOR ORDER COORDINATION. B. OWNER TO PROVIDE LIGHTING, CONTRACTOR TO INSTALL AS SPECIFIED. C. FIELD VERIFY LOCATION OF LIGHT FIXTURES w /OWNER PRIOR TO INSTALLATION D. VERIFY LOCATIONS OF ARTWORK AND WALL HANGINGS WITH OWNER PRIOR TO INSTALLATION OF TRACK LIGHTS E. DECORATIVE CHANDELIERS; MOUNT BOTTOM OF L5 @ 7-0" A.F.F., L6 @ 7-4", L7 @ 6'-8" A.F.F. MOUNT FIXTURES TO STRUCTURE WITH CHAIN SUPPLIED BY WASATCH ARTISAN WOODWORK, WEAVE CORD THROUGH CHAIN F. SPACE SUSPENDED LIGHT FIXTURES SO THAT THE SIGHT LINE FROM THE MAIN DOOR DOESN'T LINE FIXTURES UP, AS MUCH AS POSSIBLE - RANDOM PATTERN G. BOTTOM OF SUSPENDED POT RACK @ 8' -5" A.F.F. PROVIDE J -BOX ON RACK FOR TRACK LIGHTS. PAINT TO MATCH POT RACK REFERENCE SHEET A103 FOR CEILING FINISHES g L4A L4 ,-� L6 ��� 4 L4A g g L4 L7 L4 REFERENCE FIRE PROTECTION SHOP DRAWINGS FOR SPRINKLER HEAD LOCATIONS; SEE ALSO GENERAL NOTE #10 ON SHEET G0000 L6 L6 , /` '\ ' ,` `\ ,` LIGHTS IN COOLER SUPPLIED BY COOLER MFG. L4 g L4A L4 L7 kit Y L8. 0 / �/� "\ �` ,` ' \ LR RECEIVED REFLECTED CEILING PLAN s NORTH MAY 19 2010 it SCALE 1 /4" = 1' -0" T C MICHAEL C. RAYMOND STATE OF WASHINGTON DRAWN CHECKED DATE 03/17/2010 SCALE JOB NO. 10 -10 SHEET NO.