Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0412 - WOWRACK
WOWRACK 12201 TUKWILA INTERNATIONAL BL EL1O-0412 wq City ofTu kwila sy Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 0923049120 Permit Number: EL10 -0412 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Issue Date: 07/06/2010 Suite No: Permit Expires On: 01/02/2011 Tenant: Name: WOWRACK Address: 12201 TUKWILA INTERNATIONAL BL SUITE 100 , TUKWILA WA Owner: Name: INTERNATIONAL GATEWAY WEST Phone: Address: 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: TODD SEARS Phone: 206 -510 -5167 Address: 3623 EAST MARGINAL WY S , SEATTLE WA Contractor: Name: EVERGREEN POWER SYSTEMS INC Phone: 206 774 -1400 Address: 3849 1 AV S , SEATTLE WA Contractor License No: EVERGPS950BE Expiration Date: 01/05/2011 DESCRIPTION OF WORK: DATA CENTER BUILDOUT Value of Electrical: NRES: $130,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: 7 I hereby certify that I have read and governing this wo 11 be compli The granting o construction o Signature: Fees Collected: $2,451.75 National Electrical Code Edition: 2008 Date: 01 tat 1 i xa ned this'permit and know the same to be true and correct. All provisions of law and ordinances with whether specified herein or not. mit does r`t pres e to give authority to violate or cancel the provisions of any other state or local laws regulating ormance • f wor I am Tuthorized to sign and obtain this electrical permit. Date: tD7/6 (/) O Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL10 -0412 Printed: 07 -06 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0923049120 Address: Suite No: Tenant: PERMIT CONDITIONS 12201 TUKWILA INTERNATIONAL BL TUKW WOWRACK Permit Number: Status: Applied Date: Issue Date: EL10 -0412 ISSUED 06/03/2010 07/06/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting o' this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating constru1ction or the perforyhance of work. Signature: Print Name: Date: 0-7/00/1 0 doc: Cond -Elec ELI 0-0412 Printed: 07 -06 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. 1-10'` 0 4 Project No., (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: O'L- 301-1 q L)- 0 Site Address: 12201 TUKWILA INTERNATIONAL BLVD Suite Number: 100 Floor: Tenant Name: WOWRACK.COM Property Owners Name: WOW TECHNOLOGIES, INC Mailing Address: 12201 TUKWILA INTERNATIONAL BLVD New Tenant: ❑ Yes 0 .. No 98168 Zip TUKWILA City WA State "CONTACT PERSON - Who do we contact when your permit is ready to be issued' Name: TODD SEARS Mailing Address: 3623 EAST MARGINAL WAY SOUTH E -Mail Address: tsears @evergreenps.net Day Telephone: (206) 510 -5167 SEATTLE WA 98134 City State Fax Number: (206) 774 -1401 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: EVERGREEN POWER SYSTEMS, INC Mailing Address: 3623 EAST MARGINAL WAY SOUTH Contact Person: TODD SEARS E -Mail Address: tsears @evergreenps.net Contractor Registration Number: EVERGPS950BE WA 98134 City State Day Telephone: (206) 510 -5167 Fax Number: (206) 774 -1401 Expiration Date: 01/05/2011 Zip Valuation of Project (contractor's bid price): $ 130,000 Scope of Work (please provide detailed information): JOB #2415 - DATA CENTER BUILDOUT Will service be altered? ® Yes ❑ Type of Use: C oMM &I1 C Noort . Type of work: ❑ New ❑ Addition ❑ Low Voltage ® Generator Property Served by: ❑ Puget Sound Energy ® Seattle City Light No Adding more than 50 amps? ® Yes' ❑ No ❑ Service Change ❑ Fire Alarm H.\Applications \Forms - Applications On Line \22010 Applications \1.2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT 'Ps CATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF, HE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR ELECTRICAL 1 TRACTOR• Signature: A g Print Name: , EW MACKE / Day Telephone: SEATTLE City Mailing Address: 3623 EAST MARGINAL WAY SOUTH Date: v G�3 (206) 774 -1 WA State %b 56 98134 Zip IDate Application Accepted: ( ^ ''-► 1 6 Date Application Expires: d Staff Initials: FL Applications \Fortes- Applications On Line`20I0 Applications' 1 2010 - Electrical Permit Application.doc bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT 0923049120 12201 TUKWILA INTERNATIONAL BL TUKW WOWRACK Permit Number: Status: Applied Date: Issue Date: EL10 -0412 ISSUED 06/03/2010 07/06/2010 Receipt No.: R10 -01402 Initials: User ID: JEM 1165 Payment Amount: Payment Date: Balance: $63.00 07/26/2010 12:00 PM $0.00 Payee: DREW W MACKEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 05590D ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $63.00 63.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -26 -2010 ��,�� ►,A "'�s City of Tukwila o i Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT • Parcel No.: 0923049120 Permit Number: EL10 -0412 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 06/03/2010 Applicant: WOWRACK Issue Date: Receipt No.: R10 -01241 Payment Amount: $1,961.40 Initials: JEM Payment Date: 07/06/2010 12:19 PM User ID: 1165 Balance: $0.00 Payee: DREW MACKEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 006294 ACCOUNT ITEM LIST: Description 1,961.40 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 1,961.40 Total: $1,961.40 PAYMENT RECEIVED doc: Receiot -06 Printed: 07 -06 -2010 • wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us RECEIPT Parcel No.: 0923049120 Permit Number: EL10 -0412 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 06/03/2010 Applicant: WOWRACK.COM Issue Date: Receipt No.: R10 -00982 Initials: User ID: Payee: WER 1655 Payment Amount: $490.35 Payment Date: 06/03/2010 10:23 AM Balance: $1,961.40 DREW MACKEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 02528D ACCOUNT ITEM LIST: Description 490.35 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 490.35 Total: $490.35 PAYMENT REEEIVED doc: Receiot -06 Printed: 06 -03 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit (UOL'f17 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 L Project: �Ilbc��� Type of Inspection: 2400 Address: Date Called: 1 Special Instructions: Date Wanted: a.L. Requester: Phone No: Exi Approved per applicable codes. El Corrections required prior to.approval. c� COMMENTS: -- aok 461 4(6 dor rt Kf(c)rk�?,�I tiMO E of ( IA califiK/O4 Inspector: REINSPECT! Date: 61 / ©� 6 N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit fug - 2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ‘''�' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 11)0 JA- (/1/ Type of Inspection:/ Date Called: Address: 122 -0 111.6 - Special Instructions: Date Wanted: g 4 6,.. Requester: Phone No: lygApproved per applicable codes. Corrections required prior to approval. COMMENTS: / -h- - JnlDfRGQ i) (PA irs To 8e4A)e) J/1 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Date: 0, 6 /(0 Receipt No.: Date: _.�:��.s[:a...�:?�?.,.:.: _ '�'r'�.1. ,,�t .r2v -T v� 2cc�..sir..�'�i^E ^•_i" = � , - .an- et.+�"�'�.r��.z_�e:.� rttr��� 'irr�"',,ti,T^h �� INSPECTION NO. INSPECTION RECORD ��O'0u1 Retain a copy with permit _r PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V�-- 6300 South enter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ik)���, Type of Inspection: 00 Address:' Z-2-O' ' Date Called: Special Instructions: Date Wanted: 7 S a p.. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. / } COMMENTS: 64eGoie 66Ctk\ Date: 0715110 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: June 17, 2010 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Todd Sears 3623 East Marginal Wy S Seattle, WA 98134 RE: Correction Letter #1 Electrical Permit Application Number EL10 -0412 Wowrack —12201 Tukwila International Bl — Suite 100 Dear Mr. Sears, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. Building Department: Jim Benner at 206 - 431 -3679 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, tJL(' Bill Rambo Permit Technician encl File No. EL10 -0412 W:\Permit Center \Correction Letters\2010\EL10 -0412 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Building Division Review Memo Date: June 16, 2010, 2010 Project Name: WOWRACK Permit #: EL10 -0412 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Sheets E5.00 and E6.00 have conflicting information regarding overcurrent and conductor sizes. 2. Provide demand for 400 amp panel Phase 1. 3. Installation to comply with 2008 N.E.C. 702.5 Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PERMITCOORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0412 DATE: 07/06/10 PROJECT NAME: WOWRACK SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: ���jj —�1l --i b uiTding Division Public Works Fire Prevention UStructural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete txi Comments: Incomplete DUE DATE: 07/08/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/05/10 Approved Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PENT COM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0412 DATE: 06 -22 -10 PROJECT NAME: WOWRACK SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: H lul ding ivision ■ Public Works Fire Prevention Structural Planning Division n Permit Coordinator ■ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-24-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -22 -10 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PE , :. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0412 DATE: 06 -03 -10 PROJECT NAME: WOWRACK SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL STE 100 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPAR MEN S: �1 /l ��u�ilding ivision I V Public Works Fire Prevention Structural n Planning Division n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06 -08 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route 14 Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -06 -10 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: N REVIEWER'S INITIALS: DATE: Permit Center Use Only ��'�� l� CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 yy ',- PROJECT NAME: Id WI. SITE ADDRESS: 122t2 I ' M'\ V\ PERMIT NO: • EuO — vi-j t L ORIGINAL ISSUE DATE: GI kV l L9 REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIE .LAS 1 O'1 t cV L 0 ti Ol Z(,t l / Summary of Revision: , j,'jipD/� PnA\L j lit r� h- o f NA 4/1 1 .0 AP, 1, n '.1. .(/✓ S►`. l 'M. Received by: `l 3 /L REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. 1 DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) 01) City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 07101110 Plan Check/Permit Number. EL10 -0412 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # • Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: WOWRACK c;i'T• OF TUKWILA JUL 062010 PERM CENTER Project Address: 12201 TUKWILA INTERNATIONAL BLVD SUITE 100 Contact Person: TODD SEARS Phone Number: (206) 510 -5167 Summary of Revision: ADD 1200A AUXILARY KIRK KEY INTERLOCK PANEL AND ASSOCIATED (2) FEEDERS TO THE ATS. Sheet Number(s): E1.01 & E5.00 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on H:\Applications\Fotms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7-2010 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director REVISION SUBMITTAL. Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 0/21 -/ 10 Plan Check/Permit Number: EL 10 -0412 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Wowrack Project Address: 12201 Tukwila Internatioanl BI — Suite 100 Contact Person: `1-100 447-S Phone Number: tole- 5- 0 `31 (0-7 Summary of Revision: I . 644 T :. o E 6.,3 4-40.)E" 'W UnViSV--1) 7 w C -14-9-kt i �► t . Z, 41 R ?A1J P JAAsE 1 7Arn /%1 bt% - ANJO i FZFTPi) eirTF Et FIrs) t). 114f. (DP-Aftroat 3. ti t"VJ fs T t Tfl 64' 1 DO C1T/ OF TUKIMLA Sheet Number(s): I.° I t ��, 12 , EL.,1 E5; oo, VC, 4.o IJUN 2 2 2010 "Cloud" or highlight all areas of revision including date of exis • i n ot:MAIT CE _p Received at the City of Tukwila Permit Center by: _ \ l Entered in Permits Plus on I, l -1, \applications \forms - applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P ter Friendly Page • Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Evergreen Power Systems Inc UBI No. 602451324 Phone 2067741400 Status Active Address 3623 E Marginal Way S License No. EVERGPS950BE Suite /Apt. License Type Electrical Contractor City Seattle Effective Date 1/5/2005 State Wa Expiration Date 1/5/2011. Zip 98134 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ADMINISTRATOR INFORMATION License MACKEJE216JN Name Mackey, James E Status Active Business Owner Information Name Role Effective Date Expiration Date Hopkins, James Agent 01/05/2005 Bond Amount Mackey, James E President 01/05/2005 52BSBFC2870 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Z; HARTFORD FIRE INS CO 52BSBFC2870 01/03/2009 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 12/19/2008 1 INS CO OF THE WEST 2136450 01/03/2005 Until Cancelled 01/15/2009 EVANS00322 $4,000.00 01/05/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EJONV00338 6/6/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EBLAG00295 1/6/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EROMA00567 5/24/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EVANS00322 6/19/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip/Print.aspx 07/06/2010 3"C 3 #350 3 "C 3 #350 I #4 \ I #4 (3)4 "C 4 #600 I #3/0 GND FAN -I FAN -2 /0/5I1P /CY511P 8A 8A (2) ,4 #IGN w/ '\-3/4 "C 3# I 0 2 .. I /2 °C_ .. . 3 #250 w/ I #4 GND' I 200A AUXI LLARY PANEL 1Y4 "C 3 #2 w/ I #8 GND Min iff 1st FLOOR ENLARGED POWER PLAN SCALE: 1 /4" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE aFY C Permit No. Zl O' 0917, Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation a ' . adopted • ode or ordinance. Receipt of approved ` ield opy and I nditio is acknowledged. uJ I Ml By Date: City Of Tukwila BUILDING DIVISION REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 232010 Vitk- City of Tukwila BUILDING DIVISION REVISIONNO.Z___ Ft-LO -(X12 WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Revisions No: Item: Date: DESIGN REVIEW 03/18/10 PERMIT SET 06/01/10 3 CORRECTIONS LETTER #1 06/22/10 REVISION ADD 06/30/10 Project Number: Plot Date: Drawn By: 2415 07/01 /10 - 7:51am MRP Checked By: JB Arch. Bckgrnd.: 03/18/10 Drawing Nome: 2415- WOWRACK DATA CENTER.dwg Title : FIRST FLOOR ENLARGED POWER PLAN di O Tu LA JUL 08 1010 PERMIT CENTER__ PERMIT SET 7 Sheet : E1.01 08:34 am uJ 1=- 0 C 0 113 USER: mperr FILE: P: \EPS \EPS PROJECTS \2415 — WOWRACK DATA CENTER \2415 — WOWRACK DATA CENTER.dwg LJ rg- LEVEL P2 POWER PLAN SCALE: 1 /8" = :711AT 0 IF?. g \ \ -gg rg rs n V Ng evT 4 ryou gi 0 A SWITC1115AORD METER SECTION (3)4"C w/t4 #6 01v1CM CU PER. (3) 4" RISERS LINE UP w/ EXISTING CORE PLANK HOLES WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. LJ Seattle, Washington T-- , REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 2 3 2010 City of Tukwila BUILDING DIVISION RECEIVE)) CITY OF TUKWILA JUL 062010 PERMIT CENTER EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774-1400 Fax: (206) 774-1401 Revisions No: Item: Dote: 1 DESIGN REVIEW 03/18/10 2 PERMIT SET 06/01/10 3 CORRECTIONS LETTER #1 06/22/10 REVISION ADD 06/30/10 . 4;4 Project Number: 2415 Plot Date: 07/01/10 8:34am Drawn By: M RP Checked By: JB Arch. E3ckgrnd.: 03/18/10 Drawing Name: 2415-WOWRACK DATA CENTER.dwg Title : LEVEL P2 POWER PLAN 1 PERMIT SET El. DATE: Jun, 30 20 FILE: P: \EPS \EPS PROJECTS \2415 — WOWRACK DATA CENTER \2415— WOWRACK DATA CENTER_E5.00.dwg LEVEL 2 3M "C 3 #10 3 "C 3 #350 1 #4 GND 3 "C 3 #350 1#4 GND 4 "C 4 #600 Cu f 4 "C 4 #600 Cu "C 4 #600 Cu 4 "C 4 #600 Cu (2)3 "C 4 #350 1 #1 GND (3)4 "C 4 #600 1#3/0 GND Iga /o/ /o/ FAN -2 FAN -1 5HP 5HP 8A 8A PDU 1 225A W /INTERGAL XFRMR 164 CKTS UPS -1 300A MECH 600A LEVEL 1 CRITICAL LOAD RACKS 1200A MAIN SWITCHBOARD 480V, BLDG. INTERIOR AUXILLARY PNL 1200A WITH (2) KIRK KEY INTERLOCK 1/2"C 3 #2 1 #6 GND BLDG. EXTERIOR CRAC #1 45 TON 11OA LEVEL 1 LEVEL P1 LEVEL P2 21 /2 "C 3 #250 FUTURE 1#4 GND UPS NEW WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington Revisions No: Item: EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Dote: 1 DESIGN REVIEW 03/18/10 PERMIT SET 06/01/10 CORRECTIONS LETTER #1 06/22/10 4L REVISION ADD 06/30/10 (3)4 "C 4 #600 1 #3/0 GND LEVEL P1 BLDG. INTERIOR BLDG. EXTERIOR LEVEL P2 MAIN ELEC. ROOM 4 000 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 2 3 2010 City of Tukwila BUILDING DIVISION cirr oFETu�° LA JUL 062010 PERMIT CENTER r.24 Project Number: 2415 Plot Date: 06/30/10 - 3:57 pm Prawn By: MRP Checked By: JB Arch. Bckgrnd.: 03/18/10 Drawing Name: 2415 - WOWRACK DATA CENTER_E5.00.dwg Title : ONE -LINE DIAGRAM I PERMIT SET Sheet : C SCHEDULE MARK MANUFACTURER 1 MODEL COOLING CAPACITY'" FAN DATA CONNECTION SIZES ELECTRICAL DATA PHYSICAL DATA NOTES NOMINAL TONS TOTAL (MBH) SENSIBL E (MBH) GPM PRESS. DROP (ft. H20) CFM HP E.S.P. (In.) CHILLED WATER (In. O.D. Cu) CONDENSATE (In. FPT) HUMIDIFIER (In. O.D. Cu) VOLTSIPHASE FLA MCA MCA LENGTH (In.) WIDTH (In.) HEIGHT (In.) WEIGHT PO CRAC-1 LIEBERT / GW114- V- C -5 -A -3 45 541 412 110 47' 17,000 20 1.75 2 -5/8 1 -1/4 1/4 480 / 3. 77.7 97.1 110 122 34 76 2100 SEE NOTES GENERAL NOTES: " COOLING CAPACITY ® 72 °F 013, 00 °F WB, 50% RH) NOTES: 1. PROVIDE UNIT DISCONNECTS. 2. PROVIDE WITH CONDENSATE PUMPS. 3. PROVIDE WITH REAR MOUNTED RETURN WI CUSTOM FILTER RETURN SEE "AG ASSEMBLY SECTION'. 4. PROVIDE INTERLOCK & CONTROLS FOR 100% MODULATION AIRSIDE ECONOMIZER OPERATION. 5. ELECTRIC REHEAT, INFRARED HUMIDIFIER, LIEDERT ICOM CONTROLLER. O. CONDENSATE PUMP (REPLACE FACTORY CHECK VALVE W/ HIGH QUALITY DRAS5 CHECK VALVE), 7. PROVIDE DRIP PAN FOR ENTIRE UNIT, 1" LIP. 8. PROVIDE SNMP ERROR REPORTING. 4 000 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 2 3 2010 City of Tukwila BUILDING DIVISION cirr oFETu�° LA JUL 062010 PERMIT CENTER r.24 Project Number: 2415 Plot Date: 06/30/10 - 3:57 pm Prawn By: MRP Checked By: JB Arch. Bckgrnd.: 03/18/10 Drawing Name: 2415 - WOWRACK DATA CENTER_E5.00.dwg Title : ONE -LINE DIAGRAM I PERMIT SET Sheet : 1 08: 37 am USER: mperrin FILE: P: \EPS \EPS PROJECTS \2415 — WOWRACK DATA CENTER \2415 — WOWRACK DATA CENTER_E5.00.dwg Panelboard Designation Mounting Method Interrupting Ratings AIC Rating Phase (PH) PH -PH PH-N ° %VD Panel Frame Panel Mains Rating # Sets Wire AWG GND Conduit Size ' (inch) Correction Factor (TEMP) (FAC) Bus Bar Main Lugs Only TVSS NEMA Isolated Ground Neutral Conductor Rating poles (P) 0 Rpt -MSB SURFACE Fully Rated 50,000 3 480 277 2.0% 1200 1200 MLO 3 4 600 3/0 4 30 1 CU CU . 0 NO 1 NO . 100% AUTO Overcurrent Protection Device (OPD) Load Served Branch Circuit Branch Circuit Load Phase Phase Phase Load Branch Circuit Load Served Overcurrent Protection Device (OPD) No Trip P Mc OPTN Sets QTY AWG GND C (In) %VD kVA A B C kVA %VD Sets QTY AWG GND C (In) OPTN Mc P Trip No 1 300 3 P 0 MAINTENANCE BYPASS 1 3 350 4 3 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0 % 1 2 12 12 0 0 r- 0 0' 1 20 2 3 20 1 P 0 MAINTENANCE BYPASS 1 2 12 3.0% 0 3/4 0.0 % 0.0 0.0 0.0 0.0 0.0 0.0 % 1 2 12 12 0 0 0 0 1 20 4 5 20 1 P 0 MAINTENANCE BYPASS 1 2 12 7.8 0 3/4 0.0% 0.0 0.0 OA 0.0 00 0.0% 1 2 12 12 p 0 0 0 1 20 6 7 20 1 0 0 0 1 2 12 7.8 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 0 1 20 8 9 20 1 0 0 0 1 2 12 0.0 0 3/4 0.0% 0.0 0.0 0.0 0.0- 0.0' 0.0% 1 2 12 12 0 0 0 0 1 20 10 11 20 1 0 0 0 1 2 12 0.0 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 0 0 0" 0 1 20 12 13 20 1 0 0 0 1 2 12 0.0 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 0 0 0 0 1 20 14 15 20 1 0 0 0 1 2 12 0.0% 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 0 0' 0 0 1 20 16 17 20 1 0 0 0 1 2 12 1 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 0 0' 0 0 1 20 18 19 20 1 0 0 0 1 2 12 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 12 12 0 0 0 0 1 20 20 21 30 1 0 0 0 1 2 10 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 10 10 0 0 0 0 1 30 22 23 30 1 0 0 0 1 2 10 0 3/4 0.0/ 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 10 10 0 0 0 0 1 30 24 25 30 1 0 0 0 1 2 10 0 0 3/4 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 2 10 10 0 0 0 0 '1 30 26 27 30 1 0 0 0 1 2 10 SPARE 0 3/4 0.0% 0.0 0.0' 0.0 0.0 0.0 0.0% 1 2 10 10 0 0' 0 0 1 30 28 29 30 1 0 0 0 1 2 10 0 0 3/4 0.0% 0.0 0.0 0.0 0.0 ' 0.0 0.0 % 1 2 10 10 0 0', 0 0 1 30 30 31 0.0% 1 S 0 0 1 SPARE 0 S 0 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 0; 0 0 0.0 0.0 32 33 1 S 0 0 1 0 S 0 0 0.0% 0.0 0.0' 0.0 0.0 0.0 0.0% 1 0 0 0'' 0 0 0.0 0.0 34 35 S 0 0 1 S 0 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 0.0% 0 0, 0 0 0.0 0.0% 36 37 300 3 P 0 UPS #1 1 3 350 4 3 0 3.0% 13.0 472 0.0 0.0 342 3.0% 2 4 350 1 3 MECHANICAL PANEL 0 P 3 600 38 39 0 P 0 UPS #1 1 40 41 0 0 3.0% 16.0 0.0 46.8 0.0 30.8 3.0% 1 0.0% 0.0 0.0 0 MECHANICAL PANEL 0 P 1 40 41 0 SPARE P 0 UPS #1 1 42 Load 0 0 3.0% 16.0 0.0 0.0 46.8 30.8 3.0% 1 AL Aluminum Connected 0 MECHANICAL PANEL 0 p 34.2 30.8 30.8 42 Shunt Trip SWD Load kVA Ampere Calculated Demand Feeder Am pacity Total kVA Per Phase GFP GFP Ground Fault Protection LOCK Pad Lock AL Aluminum Connected 140.8 169.4 Amps Amps 47.2 46.8 46.8 SNT Shunt Trip SWD Switch Duty Rated M Lo Main Lugs Only Calculated Demand 140.8 169.4 HACR :a „. C 230 KEY HACR Hea tin g, Air Conditioning Refri g. KEY Key Lock MCB Main Circuit Breaker PERMIT GFCI 0 Ground Fault Current interrupter OPTN "''• ' " ^' "' z.,.. GFCI Ground Fault Current Interrupter P OPTN Options P GND Ground AIC Ampere Interruptingg Capacity GND Ground Project No Project Name WOWRACK.COM Engineer Project No TS 2415 Project ect Phase - Date PERMIT GND www powercaicpak'com Engineer TS CU Co pP er W GND www pow ercaiC ak`com © 2001 -2004 by Electric Power Calc Inc.; Patents Pending - EPS PROJECTS12415- WOWRACK DATA CENTERI(WOWRACK PANEL SCHEDULE 06- 22 -10.a Panelboard Designation Mounting Method Interrupting Ratings AIC Rating Phase (PH) PH -PH PH PH N %VD Panel Frame Panel Mains' Rating # Sets Wire AWG GND Conduit Size (inch) Correction Factor (TEMP) (FAC) Bus Bar MCB Options TVSS NEMA Isolated Ground Neutral Conductor Rating Poles (P> 0 Rpt -PDU SURFACE Fully Rated 10,000 3 208 277 120 2.0% 225 225 MCB 1 3 250 4 2 1/2 30 1 CU . 0 0 NO 1 NO 100% 42 Overcurrent Protection Device (OPD) Load Served Branch Circuit Load Phase Phase Phase Load Branch Circuit Load Served Overcurrent Protection Device (OPD) C KT No Trip P Mc OPTN Sets QTY AWG GND C (In) %� /D kVA A B C kVA %VD Sets QTY AWG GND C (In) OPTN Mc P Trip NKo 1 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 3/4 12 3/4 3.0% 1.0 2.0 0.0 0.0 1.0 3.0% 1 2 12 12 3/4 121 -5 RACK RECEPTACLE 3 " 0 1 20 2 3 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 3.0% 12 3/4 3.0% 1.0 0.0 2.0 0.0 1.0 3.0% 1 2 12 12 3/4 L21-5 RACK RECEPTACLE 0 0 1 20 4 5 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 7.8 12 3/4 3.0% 1.0 0.0 0.0 2.0 1.0 3D% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 0 1 20 6 7 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 7.8 12 3/4 3.0% 1.0 2.0 0.0 0.0 1.0 3.0% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 0 1 20 8 9 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 0.0 12 3/4 3.0% 1.0 0.0 2.0 0.0 1.0 3D% 1 2 12 12 3/4 121-5 RACK RECEPTACLE 0 0 1 20 10 11 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 0.0 12 3/4 3.0% 1.0 0.0 0.0 2.0 1.0 3.0% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 0 1 20 12 13 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 0.0 12 3/4 3.0% 1.0 2.0 0.0 0.0 t0 `' 3.0% 1 2 12 12 3/4 ` L21 -5 RACK RECEPTACLE 0 0 1 20 14 15 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 0.0% 12 3/4 3.0% to 0.0 2.0 0.0 to 3.0% 1 2 12 12 3/4 L21- 5RACKRECEPTACLE 0 O 1 20 16 17 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 1 12 3/4 3.0% to 0.0 0.0 2.0 to 3.0% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 0 1 20 18 19 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 12 3/4 3.0% 10 2.0 0.0 0.0 10 3.0% 1 2 12 12 3/4 L21- 5RACKRECEPTACLE 0 O 1 20 20 21 30 1 0 0 L5-30 RACK RECEPTACLE 1 2 10 10 3/4 3.0% 2.5 0.0 5.0 0.0 2.5 3.0% 1 2 10 10 3/4 1-5-30 RACK RECEPTACLE' 0 O 1 30 22 23 30 1 0 0 L5-30 RACK RECEPTACLE 1 2 10 10 ' 3/4 3.0% 2.5 0.0 0.0 5.0 2.5 3.0% 1 - 2 10 10 3/4 L5-30 RACK RECEPTACLE 0' O 1 30 24 25 30 1 0 0 L5-30 RACK RECEPTACLE 1 2 10 0 10 3/4 3.0% 2.5 5.0 0.0 0.0'' 2.5'" 3.0% 1 2 10 10 3/4 L5-30 RACK RECEPTACLE 0 O '1 30 26 27 30 1 0 0 L5-30 RACK RECEPTACLE 1 2 10 SPARE 10 3/4 3D% 2.5 0.0 5.0 0.0 2.5 3.0% 1 2 10 10 3/4 L5.30 RACK RECEPTACLE 0 O 1 30 2 8 29 30 1 0 0 L5-30 RACK RECEPTACLE 1 2 10 0 10 3/4 3.0% 2.5 0.0 0.0 5.0 2.5 3.0% 1 2 10 10 3/4 L5-30 RACK RECEPTACLE 0 O 1 30 30 31 0.0% 1 S 0 SPARE 1 SPARE 0 S 0 0.0% 0.0 0.0 0.0 0.0 0.0" " 0.0% 1 0 _ SPARE . 0 S 0.0 0.0 32 33 1 S 0 SPARE 1 0 S 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 0 SPARE 0 S 0.0 0.0 34 35 S 0 SPARE 1 S 36 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 0.0% 0 SPARE 0 S 0.0 0.0% 36 37 S 0 SPARE 1 38 39 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 0.0% 0.0 0 SPARE 0 S 0.0% 1 38 39 0 S 0 SPARE 1 40 41 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0.0% 0.0 0.0 0 SPARE 0 - S 1 40 41 0 SPARE S 0 SPARE 1 42 Load kVA 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 AL Aluminum Connected 0 SPARE 0 S 34.2 30.8 30.8 42 Shunt Trip SWD Load kVA Ampere Calculated Demand Feeder Ampacity Total kVA Per Phase GFP Ground Fault Protection LOCK Pad Lock AL Aluminum Connected 45.0 124.9 Amps 13.0 16.0 16.0 SNT Shunt Trip SWD Switch Duty Rated Mt_O Main Lugs Only Calculated Demand 45.0 124.9 AIC Ampere lnterru tin Capacity P 99 p Y 230 0 HACR :a „. C Heating, Air &Refri . 9 , 9 9 KEY Key Lock MCB Main Circuit Breaker Project No 2415 Project Phase - Date PERMIT GFCI 0 Ground Fault Current interrupter OPTN Options ^' AIC z` AmperelnterruptinggCapacity GND Ground GND www!powercaicpak.corr Project Name Project Phase - Date WOWRACK.COM PERMIT Project No 2415 Engineer TS :..:.,... »,,.:, >.. cu Copper LV GND www powercaicpak'com © 2001 -2004 by Electric Power Calc Inc.; Patents Pending -'- EPS PROJECTSI2415- WOWRACK DATA CENTERI(WOWRACK PANEL SCHEDULE 06- 22 -10., Panelboard Designation Mounting Method Interrupting Ratings AIC Rating Phase (PH) PH-PH PH-N o %VD Panel Frame Panel Mains Rating # Sets Wire AWG GND Conduit Size (inch) Correction Factor P) (FAC) (TEMP) Bus Bar Main Lugs Only VSS NEMA Isolated Ground Neutral Rating Poles (P) 0 Rpt -MECH SURFACE Fully Rated 35,000 3 480 277 2.0% 600 600 MLO 2 4 350 1 3 30 1 CU 0 NO 1 NO 100% 42 Overcurrent Protection Device (OPD) Load Served Branch Circuit Load Phase Phase Phase Load Branch Circuit Load Served Overcurrent Protection Device (OPD) NKOT Trip P Mc OPTN Sets QTY AWG GND C (In) %VD kVA A B C kVA %VD Sets QTY AWG GND C (In) OPTN Mc P Trip NK0T 1 20 1 L 0 LIGHTING 1 2 12 12 3/4 3.0% 3.4 26.4 0.0 0.0 23.0 3.0% 1 4 1 6 2 CRAC UNIT #1 0 H 3 110 2 3 40 3 0 0 VFD 1 4 8 10 1 3.0% 7.8 0.0 30.8 0.0 23.0 3.0% 1 0 CRAC UNIT #1 0 H 4 5 O 0 VFD 1 0 3.0% 7.8 0.0 0.0 30.8 23.0 3.0% 1 p .CRAC UNIT #1 0 H 6 7 O 0 VFD 1 0 3.0% J.8 7.8 0.0 0.0 0.0 ° 0.0% 1 0 SPARE p g 8 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0 ° 0./ 1 p SPARE p S 10 11 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 12 13 S` 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 14 15 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 16 17 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 18 19 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% p SPARE 0 S 20 21 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 22 23 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 24 25 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 26 27 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 28 29 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 30 31 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 32 33 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 34 35 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 36 37 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 38 39 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 40 41 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 42 Load kVA Ampere Feeder Ampacity Total kVA Per Phase GFP Ground Fault Protection LOCK Pad Lock AL Aluminum Connected 95.8 115.2 Amps 34.2 30.8 30.8 SNT Shunt Trip SWD Switch Duty Rated MLO Main Lugs Only Calculated Demand 96.7 116.3 620 „> *Y ��; *� � t HACR Heating, &Refri . g g g KEY KeyLock y MCB Main Circuit Breaker GFCI Ground ault Current F Cu ren Interrupter OPTN O ti Options ons AIC Ampere lnterru tin Capacity P 99 p Y GND Ground Project Name WOWRACK.COM Project No 2415 Project Phase - Date PERMIT Engineer TS * ii z ^' ;,,,� CU Copper Co er W GND www!powercaicpak.corr © 2001 =2004 by Electric Power Calc Inc.; Patents Pending PS PROJECTS12415- WOWRACK DATA CENTERI[WOWRACK PANEL SCHEDULE 06 -22 -10.x, REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 232010 City of Tukwila BUILDING DIVISION ciTVOFTU�n°nu+ JUL 0 6 2010 PERMIT CENTER WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington IYERGREE. POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Revisions No: Item: Dote: 1 DESIGN REVIEW 03/18/10 2 PERMIT SET 06/01/10 3 CORRECTIONS LETTER #1 06/22/10 .L REVISION ADD 06/30/10 Project Number: 2415 Plot Date: 07/01/10 - 8:37am Drawn By: MRP Checked By: JB Arch. Bckgrnd.: 03/18/10 Drawing Name: 2415 - WOWRACK DATA CENTER_E5.00.dwg Title : PANEL SCHEDULES 1.41 r tar • e.' PERMIT SET Sheet : E • 3 I #4 "C 3 #350 -3 "C 3 #350 I #4 (3)4 "C 4 #600 I #3/O GND FAN -2 5hP 8A MSB -2 300A MSB = I I200A ATS I 200A 480V 4 "C 4 #600 Cu 3/4 "C 3#10 2 1 /!"C--7. I #4 GND (3)4 "C 4 #600 w/ I#310 GND NEW CRAC #1 45 TON 110P NEW 300KW GENERATOR 480V 400A PDUI 25OA DOWN TO EXISTING. 1200A MSB ON LEVEL ...P2.. FILE COPY Permit No. LLi 0-- o3-1 12. Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation ► y adopted ode or ordinance. Receipt of approved -lei Copy an nditio s is acknowledged By 41,411r o1/40/10 City Of Tukwila BUILDING DIVISION st FLOOR ENLARGED - POWER PLAN REVISIONS No changes shall be made to the scope of Work. without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan roe' wwr f (?.r 3. CORRECTION LTR# REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 022010 City of Tukwila BUILDING DIVISION RECEIVED JUN 222010 PERMIT CENTER ELloo9I2 WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Revisions No: Item: Dote: DESIGN REVIEW 03/18/10 PERMIT SET 06/01/10 .L: \ CORRECTIONS LETTER #1 06/22/10 Project Number: Plot Date: Drown By: 2415 06/22/10 - 2:44pm MRP JB Checked By: Arch. Bckgrnd.: 03/18/10 Drawing Nome: 2415- WOWRACK DATA CENTER.dwg Title : FIRST FLOOR ENLARGED POWER PLAN Sheet : E 0 C E- C C C Llj USER: mperrin FILE: P: \EPS \EPS PROJECTS \2415 — WOWRACK DATA CENTER \2415 — WOWRACK DATA CENTER.dwg t :. „, r>, •,*., ' •.:: .::.> ...i.,, ,,,.: t .,::: '•*., ',,, V W :;,.-..„,....: ',.:,:se x %, i ‘ Y:) , i ,, ,. ... I.. . - *.• -43 WA }LP it 200IA SWITC1-15AORD SC METER SECTION 3 #01310MCM CU ) FR. 4"C. (3) 4" RISERS LINE UP w/ EXISTING CORE PLANK HOLES LEVEL P2 POWER PLAN _} SCALE: 1/8" = Minna igmenarg, novaraffm REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 02 2010 City of Tukwila BUILDING DIVISION PERMIT SET WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington rERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774-1400 Fax: (206) 774-1401 .; • ."*.I.,;....$1*,,34‘44',Y. Revisions No: Item: Dote: 1 DESIGN REVIEW 03/18/10 2 PERMIT SET 06/01/10 ACORRECTIONS LETTER #1 06/22/10 • : Project Number: 2415 Plot Date: Drawn By: 06/22/1 0 - 1:56pm MRP Checked E3y: JB Arch. E3ckgrnd.: 03/18/10 Drawing Name: 2415-WOWRACK DATA CENTER.dwg Title : LEVEL P2 POWER PLAN RECEIVED JUN 22 2010 PERMIT CENTER Sheet : DATE: Jun, 22 201 5— WOWRACK DATA CENTER \2415 — WOWRACK DATA CENTER_E5.00.dwg FILE: P: \EPS \EPS PROJECTS \24 7-3"C 3 #350 1#4 GND 3 "C 3 #350 1#4 GND (2)3 "C 4 #350 1 #1 GND (3)4 "C 4 #600 1 #3 /0 GND 1 200A MAIN SWITCHBOARD 480V, 30 CRAC #1 45 TON 1 1 OA - 2 1/2"C 3 #250 1#4 GND 4 "C SPARE 4 "C SPARE 4 "C 4 #600 Cu 300KW 480V, 400A GENERATOR CRAC SCHEDULE MARK CRAG -1 MANUFACTURER! MODEL COOLING CAPACITY* FAN DATA CONNECTION SIZES ELECTRICAL DATA PHYSICAL DATA NOMINAL TONS LIEBERT / CW114- V- C -S -A -3 45 TOTAL (MBH) 541 SENSIBL E (MBH) GPM PRESS.. DROP (ft. H20) CFM HP E.S.P. (In.) 412 110 47 17,000 20 1.75 CHILLED WATER (In. O.D. Cu) 2-5/8 CONDENSATE (In. FPT) HUMIDIFIER (In. O.D. Cu) 1 -1/4 1/4 VOLTS/PHASE 4&0/30 FLA MCA MCA LENGTH (In.) WIDTH (In.) 77.7 97.1 110 122 34 H EIGHT (In.) 76 WEIGHT (Ibs.) 2100. SEE NOTES GENERAL NOTES: COOLING CAPACITY ® 72 °F DB, 60 °F W13, 50% RH) NOTES: 1. PROVIDE UNIT DISCONNECTS. 2. PROVIDE WITH CONDENSATE PUMPS. 3. PROVIDE WITH REAR MOUNTED RETURN W/ CUSTOM FILTER RETURN SEE "AC. ASSEMBLY SECTION ". 4. PROVIDE INTERLOCK & CONTROLS FOR 100% MODULATION AIRSIDE ECONOMIZER OPERATION. 5. ELECTRIC REHEAT, INFRARED HUMIDIFIER, LIEBERT ICOM CONTROLLER, 6. CONDENSATE PUMP (REPLACE FACTORY CHECK VALVE W/ HIGH QUALITY BRASS CHECK VALVE). 7. PROVIDE DRIP PAN FOR ENTIRE UNIT, 1" LIP. 8. C'ROVIDE SNMP ERROR REPORTING. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC JUL 0 2 2010 City of Tukwila BUILDING DIVISION ECEIVED JUN 222010 PERMIT CENTER WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Revisions Item: Dote: DESIGN REVIEW 03/18/10 PERMIT SET 06/01/10 CORRECTIONS LETTER #1 06/22/10 Project Number: 2415 06/22/10 2:45pm Plot Date: Drawn By: MRP Checked By: JB Arch. Bckgrnd.: 03/18/10 Drawing Name: 241 5-WOWRACK DATA CENTER _E5.00 Title ONE -LINE DIAGRAM i PERMIT SET Sheet : E PERMIT SET 71 FILE: P: \EPS \EPS PROJECTS \2415— WOWRACK DATA CENTER \2415 — WOWRACK DATA CENTER_E5.00.dwg Panelboard Designation Mounting Method Interrupting Ratings AIC Rating 50,000 Phase (PH) 3 PH-PH 480 PH-N 277 o %VD 2.0% Panel Frame 1200 Panel Rating 1200 Mains ' MLrr w I # Sets L■.■11.,111114 AWG 600 3/0 Conduit Size i� h 4 � Correction Factor (TEMP) ` (FAC) . Bus Bar Main Lugs Only TVSS NEMA ' Isolated Ground Neutral • Conductor Rating Poles (P) Rpt -PDU Rpt -MSB SURFACE Fully Rated 30 1 CU 2.0% 0 NO . 1 NO 100% AUTO Protection CK: Overcurrent (OPD) Trip P Device Mc OPTN Load Served Branch Circuit Load Phase Phase Phase Load Branch Circuit Load. Served Overcurrent Protection Device (OPD) \\\ GND C In) %VD kVA A Load Served Overcurrent Protection Device (OPD) C kVA %VD Sets QTY AWG GND C (In) OPTN %VD 3.0% 3.0 % 3.0% kVA 10 1.0 1.0 Trip Nlco 1 300 %VD 3.0% 3.0 % 3.0% P 0 MAINTENANCE BYPASS 111 \�♦A1A�� loin, fl ® \ \ ■ 350 \® -® ®® ®- -- -- fl o 0 0 0 0 0 0 0 0 0 0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0 % 0.0% 0.0% 0.0% 0.0 0.0 o.o 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 o.o 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0 % 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 1 ®■-. 1 1 "\ 1 1 1 ® 1111 1 1111111 1 1 ® \\\ ® ® ® ■ ® ®® ®® ®® ®® ®® ®. ®. O 0 0 0 0 0. 0 0 0 0 0 0 20 2 3 20 1 2 0 i� 12 3/4 , .. ... �.: .. - O 1 20 4" 5 20 5 0 0 P 0 MAINTENANCE BYPASS 0 0 0.. 1 20 6 7 20 1 0 0 0 0 0 0 0 0 0, 0 ■. \\ 3.0 % 8 10 12 9 CRAC UNIT #1 0.0 0.0 0 0 11 2 ® 12 0 0 13 O ® 20 0 0 0 0 0 0 L5-20 RACK RECEPTACLE 14 15 3.0% 1.0 0.0 0 0 0 0 0 ■. 16 17 3/4 - L21 -5 RACK RECEPTACLE 0 0 0 0 0 0 0 ■. 1 18 19 L5-20 RACK RECEPTACLE op= NE= 0.0 0 0 0 0 0 ■. 0.0 0.0 20 21 3.0% 3.0% \\\ pii 0 0 0 0 0 ■. 1 2 2 23 L5-20 RACK RECEPTACLE 12 3/4 0 0 0 0 0 14 15 24 25 0 0 L5-20 RACK RECEPTACLE p 0 0 0 0 0 0 0 3.0% 3D% I 26 28 27 2.0 0.0 0.0 2.0 1.0 10 0 0 29 12 12 12 3/4 0 0 O 111110111111111111 ►r�r MI ailM11.411n1.41.411.4111". 1 ��� 3 \ W 350 \® WIll \= 0 0 0 0 0.0% 0.0% 0.0% 0.0% 3.0% 3.0% 3.0% 0.0 0.0 0.0 0.0 13.0 16.0 16.0 0.0 0.0 0.0 0.0 47.2 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 : 0.0 0.0 0.0 0.0 0.0 0.0 0.0 46.8 0.0 0.0 0.0 0.0 34.2 30.8 30.8 0.0% 0.0% 0.0% 0.0% I��r4 3.0% I. 3.0% `iiiielbledriftrill 3.0% 1 1 ® �. 1 ® ® 4 \\® ®® ®® ...� W 350 \f 1 0 0 0 �/ 3 0 0 0 0 0 0 30 31 2 12 12 0 0 0',. 0 0 0.0 0.0 32 33 1 2 12 0 0 0 0 0 f 20 34 3 30 1 0 0 0 r 1111 10 10 6 37 � � 3 P 0 UPS #1 MECHANICAL PANEL 0 �� . � I 38 10 3/4 L5-30 RACK RECEPTACLE 0 O 1 ' il`r1lllll®oir 2 3 41 1 0 P 0 UPS #1 MECHANICAL PANEL . 0 P ®. 42 3/4 3.0 % Load kVA Ampere 0.0 Feede r Am pacity Total kVA Per Phase 3.0% GFP Ground Fault P otection LOCK Pad Lock AL Aluminum Connected 140.8 169.4 30 30 Amps 47.2 46.8 46.8 SNT Shunt Trip SW D Switch Duty Rated M LO Main Lugs Only Calculated Demand 140.8 169.4 2.5 230 \ ? HACR Heating, Air Conditioning &Refrig. KEY Key Lock MCB Main Circuit Breaker 10 10 3/4 L5-30 RACK RECEPTACLE 27 30 GFCI Ground Fault Current Interru ter OPTN Options 1 0© © AIC \ \ ��\ \\\CU \ 9 Capacity Ampere lnterru P tin 9 GND Ground ® ® 0.0 0.0 Project Name WOWRACK.COM 0.0 5.0 Project No 2415 Project Phase -Date PERMIT 10 10 10 Engineer TS Copper LV GND _ www pow pow ercaic akcom © 2001 -2004 by Electric Power Calc Inc.; Patents Y Pending 29 30 1 0 0 L5-30 RACK RECEPTACLE EPS PROJECTS12415- WOWRACK DATA CENTER\ OWRACKPANEL SCHEDULE 06- 22 -10.. lW - 3� Panelboard Designation Mounting Method Interrupting Ratings AIC Rating Phase (PH) PH-PH PH-N e %VD Panel Frame Panel Mains Rating # Sets I L ) Wire AWG / Y.. GND Conduit Size (inch) Correction Factor (P) (FAC) Bus ` Bar MCB Options TVSS NlT/lA Isolated Ground Neutral Conductor Rating Poles (P) 0 Rpt -PDU SURFACE Fully Rated 10,000 3 208 120 2.0% 225 225 MEI 2 4 250 14 2 1/2 30 1 CU 0 NO 1 NO 100% 42 Overcurrent Protection Device (OPD) Load Served Branch Circuit Load Phase Phase 'No Phase Load Branch Circuit Load Served Overcurrent Protection Device (OPD) NKo Trip P Mc OPTN :QTt' ©® \\ 1 IS AWG \ 12 GND _v\ 12 C (In) 3/4 3/4 %VD 3.0% 3.0 % 3.0% kVA 10 1.0 1.0 \f 2.0 0.0 0.0 0.0 2.0 0.0 ®\ 0.0 0.0 2.0 10 1.0 1.0 %VD 3.0% 3.0 % 3.0% Sets 1 nu= ® QTY 2 2 \ ® 12 GND C (In) OPTN \\ Trip NO 1 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 L21 -5 RACK RECEPTACLE 3 O 1 20 2 3 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 L21 -5 RACK RECEPTACLE 0 O 1 20 4" 5 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 ` L21 -5 RACK RECEPTACLE 0 0 1 20 6 7 20 1 0 0 L5-20 RACK RECEPTACLE 1 ® 1111111= 12 12 3/4 3.0 % 1.0 2.0 CRAC UNIT #1 0.0 0.0 to 3.0% 1 2 ® 12 3/4 L21-5 RACK RECEPTACLE 0 O ® 20 8 9 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 3.0% 1.0 0.0 2.0 0.0 1.0 3.0% ®® 12 12 3/4 - L21 -5 RACK RECEPTACLE 0 0 0 O a \ 20 20 10 12 11 20 1 0 0 L5-20 RACK RECEPTACLE op= NE= 0.0 12 12 3/4 3/4 3.0% 3.0% 1.0 1.0 0.0 2.0 0.0 0.0 2.0 0.0 1.0 1.0 3.0% 3.0% \\\ pii 8 12 3/4 L21 -5 RACK RECEPTACLE 13 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 L21 -5 RACK RECEPTACLE 0 O ®` 20 14 15 20 1 0 0 L5-20 RACK RECEPTACLE SPARE 2 E® ® 12 12 3/4 3/4 3.0% 3D% 1.0 1.0 0.0 0.0 2.0 0.0 0.0 2.0 1.0 10 3.0% 3.0% 1 1 2 2 12 12 12 3/4 L21 -5 RACK RECEPTACLE 0 O 1 20 16 17 20 1 0 0 L5-20 RACK RECEPTACLE 12 3/4 L21 -5 RACK RECEPTACLE 0 O ,1 20 18 19 20 1 0 0 L5-20 RACK RECEPTACLE 1 2 12 12 3/4 3.0% to 2.0 0.0% 0.0 0.0 10 3.0% 1 2 12 12 3/4 L21 -5 RACK RECEPTACLE 0 O f 20 2 0 21 30 1 0 0 L5-30 RACK RECEPTACLE 1 © 10 10 3/4 3.0% 2.5 0.0 1 5.0 0.0 ® 3.0% 1 2 10 10 3/4 L5-30 RACK RECEPTACLE 0 O 1 30 22 2 3 30 1 0 0 L5-30 RACK RECEPTACLE 1 \ 10 10 3/4 3.0 % 2.5 0.0 0.0 5.0 ® 3.0% ®® S 10 10 3/4 L5-30 RACK RECEPTACLE` 0 0' O O ® 1 30 30 2 4 26 25 30 1 0 0 L5-30 RACK RECEPTACLE 1 © 10 10 3/4 3.0% 2.5 5.0 0.0 0.0 2.5 3.0% ® 2 10 10 3/4 L5-30 RACK RECEPTACLE 27 30 1 0 0 L5-30 RACK RECEPTACLE 1 0© © 10 10 10 10 3/4 3/4 3.0% 3.0% ® ® 0.0 0.0 0.0 5.0 0.0 0.0 5.0 \ 2.5 3.0 % 3.0% 1 1 ®. 2 10 10 10 3/4 L5-30 RACK RECEPTACLE 0 O ® 30 2 8 29 30 1 0 0 L5-30 RACK RECEPTACLE 10 3/4 L5-30 RACK RECEPTACLE 0 O - 1 30 3 0 31 1 S 0 SPARE \ \� S 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 ®® 0 SPARE 0 p 0 p nil ®�. ®■. ® S ®® 0.0 32, 34 36 38 40 33 0.0% 1 S 0 SPARE ®\\ ME= 1 SPARE 0 0 0 0 0.0% 0.0% 0.0% 0.0 0.0 0.0 0.0 0.0 0.0 27 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% \\\ 1 1 ®® ®® 0 SPARE . 35 0.0% 0.0 S 0 SPARE 0.0 0 SPARE 37 S 0 SPARE S 0 SPARE 39 29 S 0 SPARE 1 ■- 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0 0.0% ® ®® 1 0 SPARE 0' 41 SPARE 0 S 0 SPARE 1111 31 0 0.0% 0.0 0.0 SPARE 0.0 " 0.0 0.0 0.0% ® ®® 0.0% 0 SPARE 0' ® 0.0 0.0% 42 Load kVA Ampere SPARE. Feeder Am pacity Total kVA Per Phase GFP Ground Fault Protection LOCK Pad Lock AL Aluminum Connected 45.0 124.9 Amps 13.0 16.0 16.0 SNT Shunt Trip, SWD Switch Duty Rated MLO Main Lugs Only Calculated Demand 45.0 124.9 230 \ \\ \ r 1111\ ';\• *P ' %^ : HACR GFCI Heating ,AirConditioning &Refrig. Ground Fault Current Interrupter KEY OPTN Key Lock Options MCB Main Circuit Breaker S 0 \\ \\ \ \ \\ AIC Amp ere lnterrup tin ggCapacity GND Ground 0 0.0% Project Name WOWRACK.COM 0.0 Project No. 2415 Project Phase - Date PERMIT I Pending Engineer TS - 0 S cu EPSPROJECTS12415- copper WOWRACK DATA w ' CENTERI (WOWRACK GND PANEL www .pow ercaicpak:com © 2001 -2004 by Electric Power Calc Inc.; Patents SCHEDULE 06- 22 -10., Panelboard Designation Mounting Method Interrupting Ratings AC Rating Phase (PH) PH-PH PH-N o %VD Panel Frame Panel Mains Rating # Sets Wire AWG GND Conduit Size (inch I Correction Factor (TEMP) (FAC) Bus Bar Main Lugs Only TVSS NEMA Isolated Ground Neutral Conductor Rating Poles (P) 0 Rpt -MECH SURFACE Fully Rated 35,000 3 480 277 2.0% 600 600 MLO 2 4 350 30 1 CU 0 NO 1 NO 100% 42 Overcurrent Protection Device (OPD) Load Served Branch Circuit Load Phase Phase Phase Load Branch Circuit Load Served Overcurrent Protection Device (OPD) C O K Trip P Mc OPTN Sets QTY AWG GND C (In) %VD kVA A B C kVA %VD Sets QTY AWG GND C (In) OPTN Mc P Trip NKOT 1 20 1 L 0 LIGHTING 1 2 12 12 3/4 3.0% 3.4 26.4 0.0 0.0 23.0 3.0% 1 4 1 6 2 CRAG UNIT #1 0 H 3 110 2 3` 40 3 0 0.. VFD 1 4 8 10 1 3.0% 7.8 0.0 30.8 0.0 23.0 3.0% 1 .. 0 CRAC UNIT #1 0 H 4 5 O 0 VFD 1 0 3.0% 7.8 0.0 0.0 30.8 23.0 3.0% 1 0 CRAC UNIT #1 0 H 6 7 p 0 VFD 1 0 3.0% 7.8 7.8 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 8 9 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 10 11 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 12 13 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 14 15 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 16 17 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 18 19 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 20 21 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 22 23 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0 0.0% 1 0 SPARE 0 S 24 25 S 0 SPARE 1' 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0- SPARE 0 S 26 27 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 28 29 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 30 31 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE. 0 S 32 33 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 34 35 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 36 37 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 38 39 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 40 41 S 0 SPARE 1 0 0.0% 0.0 0.0 0.0 0.0 0.0 0.0% 1 0 SPARE 0 S 42 Load kVA Ampere Feeder Am pacity Total kVA Per Phase GFP Ground Fault Protection LOCK Pad Lock AL Aluminum Connected 95.8 115.2 Amps 34.2 30.8 30.8 SNT Shunt Trip swD Switch Duty Rated MLO Main Lugs Only Calculated Demand 96.7 116.3 620 \ \\ \ .„ \x\ HACK Heating ,AirConditioning &Refrig. KEY Key Lock MCB Main Circuit Breaker GFCI Ground Fault Current I rr me u ter P Options O tions ..`.. :.:::...::.::.::::::::::..\.. % ��\ \ Ii: Ampere Interrupt mggCapacity GND Ground Project Name Project Phase - Date WOWRACK.COM PERMIT Project No 2415 Engineer TS \ Copper Lv; GND www pow ercalcpak.com © 2001 -2004 by Electric Power Calc Inc.; Patents Pending PS PROJECTS\2415 WOWRACK DATA CENTER\[WOWF?ACK PANEL SCHEDULE_06 - 22 -10.xr REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC JUL 022010 City of Tukwila BUILDING DIVISION RECEIVED JUN 22 2010 PERMIT CENTER WOWRACK GATEWAY CORP. PARK BUILDING B 12201 Tukwila Intl. Blvd. Seattle, Washington Revisions No: Item: EVERGREEN POWER SYSTEMS INC. Electrical Contracting and Engineering 3623 E. Marginal Way South Seattle, Washington 98134 Phone: (206) 774 -1400 Fax: (206) 774 -1401 Dote: DESIGN REVIEW 03/18/10 2 PERMIT SET 06/01/10 CORRECTIONS LETTER #1 3 # 06/22/10 Project Number: 2415 Plot Date: 06/22/1.0 1:55pm Drawn By: M RP Checked By: JB Arch. Bckgrnd.: 03/18/10. Drawing Name: 2415 - WOWRACK DATA CENTER E5.00. .1v 51 .. f.:. -4.444 : ....• 4.� Title : PANEL SCHEDULES ?rr..+e.ral:w Sheet : E6