Loading...
HomeMy WebLinkAboutPermit D06-459 - Bess Residence - Garage DemolitionBESS DEMOLITION 1394051 AVS EXPIRED 06 -17 -07 D06 -459 Parcel No.: 1670400025 Address: 13940 51 AV S TURIN Suite No: Tenant: Name: BESS DEMOLITION Address: 13940 61 AV S , TUKWILA WA Owner: Name: ZION MARY B Address: 13940 61ST AVE S , TUKWILA WA 98168 Phone: Contact Person: Name: SHANE MCDOUGALL Address: 11016 12 AV SW , SEATTLE WA 98146 Phone: 206 909 -8279 Contractor: Name: EVERLAST CONST & ASPHALT LLC Address: 11016 12TH AVE SW , SEATTLE WA 98146 Phone: (206)909 -8279 Contractor License No: EVERLCA966QH DESCRIPTION OF WORK: DEMOLITION OF 620 SF DETACHED GARAGE doc: IBC -10/06 City of Tukwila Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us DEVELOPMENT PERMIT Value of Construction: $1,600.00 Fees Collected: $120.96 Type of Fire Protection: International Building Code Edition: 2003 Type of Construction: VB Occupancy per IBC: * *continued on next page ** Permit Number: D06 -459 Issue Date: 12/19/2006 Permit Expires On: 06/17/2007 Expiration Date: 11/08/2008 Steven M. Mullet, Mayor • • D06 -459 Printed: 12 -19 -2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: N N N Permit Center Authorized Signature: NI VIA I hereby certify that I have read and governing this work will be compile The granting of this permit does not presume to construction or the performansg6f work. I Signature: Print Name: � City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http. //www.ci.tukwila.wa.us Number: 0 Start Rime: Volumes: Cut Start Rime: Private: Profit: N Private: 0 c.y. Permit Number: Issue Date: Permit Expires On: Size (Inches): 0 End Rime: Fill 0 c.y. End Rime: Public: Non - Profit: N Public: Steven M. Millet, Mayor Steve Lancaster, Director D06 -459 • 12/19/2006 06/17 /2007 A/--- plt iaA Q Date: 1 I 1 s permit and know � the same to be true and correct. All provisions of law and ordinances er specifjjed herein or not. authority to violate or cancel the provisions of any other state or local laws regulating thorized to sign and obtain this development permit. �,yr Date: /a. / `�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. • doc: IBC-10 /06 D06 -459 Printed: 12 -19 -2006 Parcel No.: 1670400025 Address: 13940 51 AV S TUKW Suite No: Tenant: BESS DEMOLITION 1: ** *BUILDING DEPARTMENT CONDITIONS * ** doc: Cond -10/06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: httn: / /www.ci.tukwila.wa.us PERMIT CONDITIONS * *continued on next page ** Permit Number: Status: Applied Date: Issue Date: • D06 -459 ISSUED 12/05/2006 12/19/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to • start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly 1111 or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248 - 6630). • 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. • • D06 - 459 Ftrinted: 12-19-2006 Signature: Print Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authori • violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Date: i U doc: Cond -10/06 006459 Printed: 12 -19 -2006 CITY OF TUKWIIA,.� Community Development apartment Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www. c i tukwi la. wa. us Site Address: ^0c7 t re'c a Tenant Name. Property Owners Name: Mailing Address: 2 2- 2- ry • /8' ji CONTACT PERSON rrara.gt AP .d Name: Mailing Address: /1014 — /2 7 E -Mail Address: Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** who do we contact when your permit is ready to be issued GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) gve.%9-sJ7 (PAhr7 uc7 t 4 Company Name: Mailing Address: / d - - Z 7 1 Pe. Contractor Registration Number: Company Name: Mailing Address: Q:UppliationsWOnns- Applications On LincV •2006 • Permit Application Revised' 9-2006 bh q{S1 (S3-I eaec, Building Pern,o. Mechanical Permit No ° Plumbing/Gas PermitNo.' Public Works Permit No. Project No. or ofce use atilt') King Co Assessor's Tax No.: 1 1 u"1 CY Suite Number: New Tenant: Day Telephone: 245 G Adige s .G17-1Sen-et City City Contact Person: Day Telephone: E -Mail Address: Fax Number: ❑ .... Yes State State Floor: ❑ ..N Fax Number: 9, l City State Zip / Contact Person: Day Telephone: 2 - 6 9 , 8 E -Mail Address: Fax Number: Expiration Date: ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Zip Page 1 of 6 )l Valuation of Project (contractor's bid price): $ /64 d '/ Existing Building Valuation: $ arne") '< O/ (.)2? • • %/P a // Scope of Work (please provide detailed information): Will there be new rack storage? ❑.... Yes ... No If yes, a separate permit and plan submittal will be required. O PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) _ *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: 'Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Q: Applicuions\Porms- Appliaiions On Line\3-2006 - Permit Applica6ondoc Revised: 9 -2006 bh Page 2 of 6 Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Drinking fountain or water cooler (per head) Wash fountain Gas piping outlets Bidet Food -waste grinder, commercial Receptor, indirect waste Clothes washer, domestic Floor drain Sinks Dental unit, cuspidor Shower, single head trap Urinals Dishwasher, domestic, with independent drain Lavatory Water Closet Building sewer or trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Additional medical gas inlets/outlets — six or more Industrial waste pretreatment interceptor, including its trap and vent, except for kitchen type grease interceptors Repair or alteration of water piping and/or water treating equipment Repair or alteration of drainage or vent piping Medical gas piping system serving one to five inlets/outlets for specific gas 1 AND GAS PIPINGRMIT INFORMATION - 206-431 ' PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Plumbing work (contractor's bid price): $ Valuation of Gas Piping work (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'l Building Code): Occupancy (per Int'1 Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Q tApplications tPanne-Applications On LineV -2006 - Permit Application.doc Revised. 9-2006 bh Page 5 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Print Name: Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS QcUTIpRfZED AGENT: Signature: Date: mod( d ee a S Mailing Address: /2 2 -- /v t /8S`M df #/ 4 / Date Application Expires: cOl ccicei— I Date Application Accepted: Q Wpplications\Fonns- Applications On LineU -2006 - Permit Application doc Revised: 9 -2006 bh Ible to all pcnnits In this ap'j'(icatton Day Telephone: c$ o e e/»e. LAM 9e/ c 33 City State Zip Page 6 of 6 Parcel No.: 1670400025 Address: 13940 51 AV 5 TUNNY Suite No: Applicant: BESS DEMOLITION Receipt No.: R06 -01908 Payee: FRED L. BESS ACCOUNT ITEM LIST: Description BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cttukwila.wa.us RECEIPT Initials: JEM Payment Date: 12/05/2006 02:91 PM User ID: 1165 Balance: $0.00 TRANSACTION LIST: Type Method Description Amount Payment Check 10681 120.96 Account Code Current Pmts 000/322.100 000/345.830 000/386.904 Permit Number: D06 - 459 Status: PENDING Applied Date: 12/05/2006 Issue Date: Payment Amount: $120.96 70.58 45.88 4.50 Total: $120.96 2382 12/06 9715 TOTAL 120.96 doe: Receipt -06 Printed: 12 -05 -2006 05 -07 -2007 SHANE MCDOUGALL 1101612 AV SW SEATTLE WA 98146 RE: Permit No. D06 -459 13940 51 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be in writtne and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 06/17/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, cli far Marshall, Permit Technician xc: Permit File No. D06-459 Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 ACTIVITY NUMBER: 006 -459 DATE: 12 -05 -06 PROJECT NAME: BESS DEMOLITION SITE ADDRESS: 13940 51 AV S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Pulp, lic Works Din th 12-1.0(e DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Documents/routing slip.doc 2 -2g -02 ...PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP lilt tic- PAPt�� Fire Prevention Q�J Structural Incomplete ❑ TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: Approved with Conditions DATE: DATE: Plann tt t ing Division Ai Permit Coordinator ❑ DUE DATE: 12-07-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: No further Review Required DUE DATE: 01 -04-07 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: License Information License EVERLCA966QH Licensee Name EVERLAST CONST & ASPHALT LLC Licensee Type CONSTRUCTION CONTRACTOR UBI 602443230 Ind. Ins. Account Id #2 Business Type LIMITED LIABILITY COMPANY Address 1 11016 12TH AVE SW Address 2 City SEATTLE County KING State WA Zip 98146 Phone 2069098279 Status ACTIVE Specialty 1 PAVING /STRIPING Specialty 2 SANITATION SYSTEM SIDE SEWER Effective Date 11/8/2004 Expiration Date 11/8/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 PLATTE RIVER INS CO 41063815 03/15/2006 Until Cancelled $6,000.00 03/15/2006 Business Owner Information Name Role Effective Date Expiration Date MCDOUGALL, SHANE PARTNER/MEMBER 11/08/2004 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 % Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. • • • https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= EVERLCA966QH 12/19/2006 I MON. IN CASE STA 10 +00 TBM EL- 117.58 %1 - S� M U1 m D m v m'1 i mJ Ti L' I1y � HOUSE r, I & UTILITIES. EASEMENT'(-O• }' I 10 12' SW 1/4 OF SECTION 14, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M. BESS SHORT PLAT - SITE IMPROVEMENTS LEGEND EX. STORMDRAIN 1. ll. S 139TH ST EX. WATER � "'--''' °"•-'-'--'- '••'• -° EX. CHAtNLINK FENCE I I EX. WOOD FENCE I GRAPHIC SCALE ; _I EX. SEWER MANHOLE !J (:. ?k..- ,._,i5•4 ,.. I!r'•.4'�_u w p •1 I C61•I•:h:TC ( IN FELT') RCTII DNC I Inch . 20 fl jAl �(C: " -•- T^'.v�:•,•uw:'•I24 't.''•' 7 l9iN +iiu�i SOuzI4 I, � I•'' •.., i ,� { :!11,•,3'(,.; '49' 92.92' N88OB "W 342.93' 8. ,L; I \� n ,n S� M U1 m D m v m'1 i mJ Ti L' I1y � HOUSE r, I & UTILITIES. EASEMENT'(-O• }' I 10 12' SW 1/4 OF SECTION 14, TOWNSHIP 23 NORTH, RANGE 4 EAST, W.M. BESS SHORT PLAT - SITE IMPROVEMENTS LEGEND EX. STORMDRAIN .. - ... EX. SEWER S 139TH ST EX. WATER - NBB'34'06 "W 558.50'(C) - 556.01'(P) "'--''' °"•-'-'--'- '••'• -° EX. CHAtNLINK FENCE I I EX. WOOD FENCE I GRAPHIC SCALE ; _I EX. SEWER MANHOLE !J (:. ?k..- ,._,i5•4 ,.. I!r'•.4'�_u w p •1 I EX. CLEANOUi EX. CATCH BASIN C61•I•:h:TC ( IN FELT') RCTII DNC I Inch . 20 fl jAl �(C: " -•- T^'.v�:•,•uw:'•I24 't.''•' 7 l9iN +iiu�i SOuzI4 I, � I•'' •.., i ,� { :!11,•,3'(,.; '49' 92.92' N88OB "W 342.93' 1; EX. STORM MANHOLE EX. UTILITY POLE W /ANCHOR '• EX. MAILBOX - _� - - ._. - -I�.•�.: +.. (G) - .:Ip,.OIP) Uc1� + 278.93(C) EX. CAS METER -ciA' _ -._.__ 20 I •• •I - -- '1` EX GAS ­ 20'/ . fRT B.S..L., •A Dt.. FRONT y { L� ACCESSrPAVEMENT I I• E %. POWER POLE / CENTERLINE ( B.S.B.L. •ti ` -• - :1 a'AST SIDE I 18'FtNr -t l LOT 3\ T., r '`' EX. WATER VALVE t��OSD6 I h i au ! LOT/ 2 -T3!I_ 6,802 SF r"1 F UI EX. WATER METER w � _. _ I + -�• ••1 EX. FIRE HYDRANT �n51•LI 7 -TO OERf.1AOt'C[) ! ( •. 64 IU� ___._ �._ _ ! L _ .L~ _ /:� t '•1 i {i SV. MONUMENT TO HL Rft1pVlU• • ^ti -' I z ''� -I,•` •�.- y� Ilept • u. •_ - _ _I� _ J I "•.. ASPI!AL7 ,� 7.i q,_ ,: EX. SIGN I'i AIL" L - =`,. _ ._. - "i GARAGE . , 71. !C 7•';C:.2 Ri 1 r,.,...... _ 92.85' \_' _ �•�{ ; • �otle - JJ rllt APN ASSESSOR'S PARCEL NUMBER .-. _ N88'49�05'W �;T 192.8 yvo• 1 -MOVED f r.3 I-I�j• IMPERVIOUS SURFACES !•/ °' �! "' TOTAL EXISTING: 5,284 SF 0,121 AC / , ; ;°`COfyCSEFE . ,III � �'7T � 1 • \ � I u1 ti'•5i TOTAL PROPOSED: 14,800 SF 0.340 AC •- -unl ITV'Onb'` .W.\ J �� �•' ' NET INCREASE: 9,516 SF . 0.218 AC •SL SIDE +' TYP. f rol \ 9-07'90 \ (c)(P) �' REVIEWED FOR 7. ALL MERINOS AND MATERIALS SHALL MELT TIO OF STANDARDS, DEVELOPMENT GUIDELINES AND DESIGN AND CONSTRUCTION STANDARDS, UNLCSS OTHERWISE APPROVED BY THE PUBLIC WORKS DIRECTOR. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF RECORD DRAWINGS ON -SITE. - - - - - - - - - - - - - - - N89'19'08 "W 556_59'(C) _555.80'(P) COD q co c.,MP�IANC 9, CONTRACTOR SHALL PROVIDE RECORD DRAWINGS PRIOR TO PROJECT FINAL --- ---{{{ _ _ APPROVAL - - - - - - - - 10. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AND STREET MAINTENANCE +\ I I` Py./���1f1 PLAN FOR PUBLIC WORKS APPROVAL BEFORE IMPLEMENTATION. S 142TH ST I r 7 11. ALL SURVEYING FOR PUBLIC FACILITIES SHALL BE DONE UNDER THE DIRECTION ( OF A WASHINGTON LICENSED LAND SURVEYOR. VERTICAL DATUM SHALL BE DEC VD 1988. FOR PROJECTS WITHIN A FLOOD CONTROL ZONE. THE PERMITTEE 44. 14 2006 SHALL PROVIDE CONVERSION CALCULATIONS TO NAVD 1929. HORIZONTAL DATUM BE STATE PLANE COO 12. T E CONTRACTOR SHALL REPLAICE• OR RELOCATE ALL SIGNS DAMMAGED OR m° I Ow , REMOVED DUE TO CONSTRUCTION. II • t%rm' Pae W el is faD en+ors and omit l4ppntnrdl of oo does not aut xdm the 'violation of any Or ordinance. Re m# Of approved Field , ons Is aftowledged• • By 'e 'e4ee-) -- 41- 0 (_ __ City of TLjkwila BUILDING DIVISION X: \05510 \Ong \05510M00L6.g LEGAL DESCRIPTION C of ukwi la TITLE PER ORDER N0.205102544 ISSUED BY STEWART TITLE GUARANTY COMPANY DATED DECEMBER 29, 2005. R111 1. DING DIVTSIO N LDT 3' F BLOCK RECORDED I, D IN VOLUME ACRE PLATS, TRACTS, ACCORDING TO 111E PLAT. THEREOF RECORDED IN VOLUME 11 OF PLATS, PACE 85, RECORDS OF KING COUNTY, WASHINGTON EXCEPT THAT PORTION THEREOF CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED RECORDED UNDER RECORDING NO. 613586, RECORDS OF KING COUNTY, WASHINGTON: AND EXCEPT THE EAST 64 FEET THEREOF. No changes shall to the scope c.r 1-: crth without prior approval of Building Divisinn. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SHEET INDEX CIA COVER SHEET C1.2 T.E.S.C, PLAN AND DETAILS CI,3 GRADING, DRAINAGE, UTILITY AND PAVING PLAN ('nVn n�KrllA VICIINTITYGMAP NOT CONTACT INFORMATION SITE: 13940 51ST AVENUE SOUTH SEATTLE, WA 98168 APN: 1670406025 ENGINEER /SURVEYOR: OUNCANSON COMPANY, INC. 145 SW 1557H STREET, SUITE 102 SEATTLE, WA 98166 CONTACT: HAROLD DUNCANSON, P.E. (206) 244 -4141 APPLICANT: FRED L BESS PROPERTIES 1222 NORTH 185TH, SUITE 101 SHORELINE, WA 98133 CONTACT: FRED L. BESS (206) 459 -1534 UTILRIES /SERVICES WATER: KING COUNTY WATER DISTRICT 1125 2489 SOUTH 150TH STREET SEATAC, WA 98185 (206) 242 -9547 SEWER: TUKWLA SEWER UTILITY 600 MINKLER BLVD. TUKWLA, WA 98188 (200) 433 -1804 FIRE: TUKWILA FIRE DEPARTMENT HEADQUARTERS STATION 51 444 ANDOVER PARK EAST TUKWLA, WA 98188 (206) 575 -4404 SCHOOL: SEATTLE SCHOOL DISTRICT /406 4540 SOUTHI,144TH STREET TUKWLA. WA 98160 (206) 901 -8000 TELEPHONE: OWEST POWER: SEATTLE CITY LIGHT (800) 862 -1181 GAS: PUGET SOUND ENERGY 1 -800- 321 -4123 TREE LEGEND DECIDUOUS TREE AL -ALDER AL12 MP -MAPLE TYPE -' DS- DECIDUOUS TRUNK DIAMETER (IN) MA.MADRONA OK -OAK ® CH CHERRY EVERGREEN TREE CE. CEDAR TO BE OF- DOUGLAS FIR J DFIS HE- HEMLOCK RETAINED 195.2 FT. PINE "-TOP EL IF MEASURED HO -HOLLY NOTE: TREE DRIP LINES ARE NOT TO SCALE. TREE SYMBOLS REFERENCE TRUNK LOCATION ONLY. TRUNK DIAMETERS WERE APPROXIMATED AT 3.5' TO 4' ABOVE GROUND LEVEL. TREES LESS THAN 6" NOT LOCATED EXCEPT AS SHOWN T4rL" NOTE: TOTAL EXPECTED CUT AND FILL FOR SHORT PLAT BUILDOUT - 250 CY (TO BE BALANCED ON SITE). BENCHMARK IS: lIC17 -5 CAV' 10NI BRASS SK IN NORTH DEL 0 5 7.005 SIDEWALKOOF 144TIl ST. OVERPASS nv UNDERGROUND UTILITIES EXIST IN THE AREA AND OVER 1 -5. UTILITY INFORMATION SHOWN MAY BE INCOMPLETE. ELEV.- 163.25 FEET STATE LAW REQUIRES THAT CONTRACTOR CONTACT PERNITGENTER THE ONE -CALL UTILITY LOCATE SERVICE AT LEAST 48 HOURS BEFORE STARTING ANY CONSTRUCTION. 1 -800- 424 -5555 ,! h,, s��2�i�3s��1I� �ifl ��1I��4] T! fi�Ii :�ilililil5.Il�6I. I � ♦1��V11� .. T 1{ P . SIn[e18721• 0 4 �b £... Z WO iiii�iin IIiI 11i�lii�i�����1 -11 411111111 iilfiii1i���li�ii16 iiliiii1 DUNCANSON Cornluny, IM IISSW IJLA.U-4 5.11, 107 Se.", W Al g - 9d1" PAnnr 206.744.4141 Aar 2&1244.4463 W ff s I o E a- 1J3� CO $ Z M 0 Z 0 N iT J O CO co W M L _ 0- EA OZ UQ 13 rwALL.EA;T slcE I' G_ ENERAL NOTES. 0* REA LOT 1 IB.S.B LR -It ` I I I. AT LEAST ONE WEEK BEFORE BEGINNING CONSTRUCTION, CONTACT PUBLIC �'•T,.� WORKS UTILITIES INSPECTOR AND SCHEDULE A PRECONSTRUCTION MEETING. 2. NOTIFY THE UTIUIIES INSPECTOR AT 206 14,459 SF �4r - 433 -0179 AT LEAST 48 HOURS (2 WORKING DAYS) BEFORE STARTING PROJECT SITE I l� '• WORK. 3. REQUEST A PUBLIC WORKS UTILITY INSPECTION 11,313._ -6 I CET- /• �.r,;- "^TI`16 `\ •),�'9'iI'(GJ'- 2256fj(FT r 2. {`' _ I, AT LEAST 24 HOURS (I WORKING DAY) IN ADVANCE BY CALLING 2D6 -433 -0179. 4. THE CONTRACTOR ASSUMES SOLE RESPONSIBILITY FOR WORKER SAFETY, AND DAMAGE TO STRUCTURES AND IMPROVEMENTS RESULTING FROM CONSTRUCTION ._•( 1TW _,__ - -_.b :L.B'- C) 1 "'J',.Y. -., 1, -- -� ;Z -- - -- -- =;IG- __ ____27B.7T(C) '� N88'S6'37"W 342.78' -- rl OPERATIONS. _ 5. THE CONTRACTOR SHALL HAVE THE PERMIT(S) AND CONDITIONS, THE APPROVED T . ! «s 276.77*(.,) PLANS, AND A CURRENT COPY OF CITY OF IUKWLA DEVELOPME10 GUIDEL4NES AND DESIGN AND CONSTRUCTION STABDARAT AVAILABLE AT THE JOB SITE. r1 "'' =I � 6. ALL WORK SHALL CONFORM TO THESE APPROVED DRAWINGS. ANY CHANCES •' L FROM THE APPROVED PLANS REQUIRE PRE - APPROVAL FROM THE OWNER, THE ENGINEER, AND T1IE CITY OF IUKWILA. REVIEWED FOR 7. ALL MERINOS AND MATERIALS SHALL MELT TIO OF STANDARDS, DEVELOPMENT GUIDELINES AND DESIGN AND CONSTRUCTION STANDARDS, UNLCSS OTHERWISE APPROVED BY THE PUBLIC WORKS DIRECTOR. CONTRACTOR SHALL MAINTAIN A CURRENT SET OF RECORD DRAWINGS ON -SITE. - - - - - - - - - - - - - - - N89'19'08 "W 556_59'(C) _555.80'(P) COD q co c.,MP�IANC 9, CONTRACTOR SHALL PROVIDE RECORD DRAWINGS PRIOR TO PROJECT FINAL --- ---{{{ _ _ APPROVAL - - - - - - - - 10. CONTRACTOR SHALL PROVIDE TRAFFIC CONTROL AND STREET MAINTENANCE +\ I I` Py./���1f1 PLAN FOR PUBLIC WORKS APPROVAL BEFORE IMPLEMENTATION. S 142TH ST I r 7 11. ALL SURVEYING FOR PUBLIC FACILITIES SHALL BE DONE UNDER THE DIRECTION ( OF A WASHINGTON LICENSED LAND SURVEYOR. VERTICAL DATUM SHALL BE DEC VD 1988. FOR PROJECTS WITHIN A FLOOD CONTROL ZONE. THE PERMITTEE 44. 14 2006 SHALL PROVIDE CONVERSION CALCULATIONS TO NAVD 1929. HORIZONTAL DATUM BE STATE PLANE COO 12. T E CONTRACTOR SHALL REPLAICE• OR RELOCATE ALL SIGNS DAMMAGED OR m° I Ow , REMOVED DUE TO CONSTRUCTION. II • t%rm' Pae W el is faD en+ors and omit l4ppntnrdl of oo does not aut xdm the 'violation of any Or ordinance. Re m# Of approved Field , ons Is aftowledged• • By 'e 'e4ee-) -- 41- 0 (_ __ City of TLjkwila BUILDING DIVISION X: \05510 \Ong \05510M00L6.g LEGAL DESCRIPTION C of ukwi la TITLE PER ORDER N0.205102544 ISSUED BY STEWART TITLE GUARANTY COMPANY DATED DECEMBER 29, 2005. R111 1. DING DIVTSIO N LDT 3' F BLOCK RECORDED I, D IN VOLUME ACRE PLATS, TRACTS, ACCORDING TO 111E PLAT. THEREOF RECORDED IN VOLUME 11 OF PLATS, PACE 85, RECORDS OF KING COUNTY, WASHINGTON EXCEPT THAT PORTION THEREOF CONVEYED TO KING COUNTY FOR ROAD PURPOSES BY DEED RECORDED UNDER RECORDING NO. 613586, RECORDS OF KING COUNTY, WASHINGTON: AND EXCEPT THE EAST 64 FEET THEREOF. No changes shall to the scope c.r 1-: crth without prior approval of Building Divisinn. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SHEET INDEX CIA COVER SHEET C1.2 T.E.S.C, PLAN AND DETAILS CI,3 GRADING, DRAINAGE, UTILITY AND PAVING PLAN ('nVn n�KrllA VICIINTITYGMAP NOT CONTACT INFORMATION SITE: 13940 51ST AVENUE SOUTH SEATTLE, WA 98168 APN: 1670406025 ENGINEER /SURVEYOR: OUNCANSON COMPANY, INC. 145 SW 1557H STREET, SUITE 102 SEATTLE, WA 98166 CONTACT: HAROLD DUNCANSON, P.E. (206) 244 -4141 APPLICANT: FRED L BESS PROPERTIES 1222 NORTH 185TH, SUITE 101 SHORELINE, WA 98133 CONTACT: FRED L. BESS (206) 459 -1534 UTILRIES /SERVICES WATER: KING COUNTY WATER DISTRICT 1125 2489 SOUTH 150TH STREET SEATAC, WA 98185 (206) 242 -9547 SEWER: TUKWLA SEWER UTILITY 600 MINKLER BLVD. TUKWLA, WA 98188 (200) 433 -1804 FIRE: TUKWILA FIRE DEPARTMENT HEADQUARTERS STATION 51 444 ANDOVER PARK EAST TUKWLA, WA 98188 (206) 575 -4404 SCHOOL: SEATTLE SCHOOL DISTRICT /406 4540 SOUTHI,144TH STREET TUKWLA. WA 98160 (206) 901 -8000 TELEPHONE: OWEST POWER: SEATTLE CITY LIGHT (800) 862 -1181 GAS: PUGET SOUND ENERGY 1 -800- 321 -4123 TREE LEGEND DECIDUOUS TREE AL -ALDER AL12 MP -MAPLE TYPE -' DS- DECIDUOUS TRUNK DIAMETER (IN) MA.MADRONA OK -OAK ® CH CHERRY EVERGREEN TREE CE. CEDAR TO BE OF- DOUGLAS FIR J DFIS HE- HEMLOCK RETAINED 195.2 FT. PINE "-TOP EL IF MEASURED HO -HOLLY NOTE: TREE DRIP LINES ARE NOT TO SCALE. TREE SYMBOLS REFERENCE TRUNK LOCATION ONLY. TRUNK DIAMETERS WERE APPROXIMATED AT 3.5' TO 4' ABOVE GROUND LEVEL. TREES LESS THAN 6" NOT LOCATED EXCEPT AS SHOWN T4rL" NOTE: TOTAL EXPECTED CUT AND FILL FOR SHORT PLAT BUILDOUT - 250 CY (TO BE BALANCED ON SITE). BENCHMARK IS: lIC17 -5 CAV' 10NI BRASS SK IN NORTH DEL 0 5 7.005 SIDEWALKOOF 144TIl ST. OVERPASS nv UNDERGROUND UTILITIES EXIST IN THE AREA AND OVER 1 -5. UTILITY INFORMATION SHOWN MAY BE INCOMPLETE. ELEV.- 163.25 FEET STATE LAW REQUIRES THAT CONTRACTOR CONTACT PERNITGENTER THE ONE -CALL UTILITY LOCATE SERVICE AT LEAST 48 HOURS BEFORE STARTING ANY CONSTRUCTION. 1 -800- 424 -5555 ,! h,, s��2�i�3s��1I� �ifl ��1I��4] T! fi�Ii :�ilililil5.Il�6I. I � ♦1��V11� .. T 1{ P . SIn[e18721• 0 4 �b £... Z WO iiii�iin IIiI 11i�lii�i�����1 -11 411111111 iilfiii1i���li�ii16 iiliiii1 DUNCANSON Cornluny, IM IISSW IJLA.U-4 5.11, 107 Se.", W Al g - 9d1" PAnnr 206.744.4141 Aar 2&1244.4463 W ff s I o E a- 1J3� CO $ Z M 0 Z 0 N iT J O CO co W M L _ 0- EA OZ UQ