Loading...
HomeMy WebLinkAboutPermit EL10-0616 - COMPLETE OFFICEThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL10 -0616 Complete Office 11521 East Marginal Way South RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 12 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. COMPLETE OFFICE 11521 EAST MARGINAL wys EL1O-0616 City a"Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.ci.tulcwila.wa.us ELECTRICAL PERMIT Parcel No.: 1023049076 Address: 11521 EAST MARGINAL WY S TUKW Suite No: Permit Number: EL10 -0616 Issue Date: 08/18/2010 Permit Expires On: 02/14/2011 Tenant: Name: COMPLETE OFFICE Address: 11521 EAST MARGINAL WY S , TUKWILA WA Owner: Name: WOODRIDGE PARTNERS LLC Phone: Address: 11521 EAST MARGINAL WAY #100 , SEATTLE WA Contact Person: Name: DOUG JARVIS Phone: 206 - 396 -2856 Address: PO BOX 266 , HOBART WA Contractor: Name: D J ELECTRIC & CONSTRUCTION Phone: 425 432 -2513 Address: P 0 BOX 266 , HOBART WA Contractor License No: DJELECI027L9 Expiration Date: 06/29/2012 DESCRIPTION OF WORK: INSTALL A 30KVA TRANSFORMER AND PANEL, AND WIRE MEZZANINE TENANT IMPROVEMENT Value of Electrical: NRES: $21,800.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Fees Collected: $588.62 National Electrical Code Edition: 2008 Permit Center Authorized Signature: Date: I hereby certify that I have read and : xami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • with, whether specified herein or not. The granting of this per construction or the pe Signature: Print Name: uthority to violate or cancel the provisions of any other state or local laws regulating orized to sign and obtain this electrical permit. This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL1 0-0616 Printed: 08 -18 -2010 Parcel No.: Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 1023049076 11521 EAST MARGINAL WY S TUKW COMPLETE OFFICE Permit Number: Status: Applied Date: Issue Date: EL10 -0616 ISSUED 08/02/2010 08/18/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit doe not p sume to give • uthority to violate or cancel the provision of any other work or local laws regulating constructio •!. r the . erf. ' . - e'o , ork. Signature: Print Name: ��i A doc: Cond -Elec EL10 -0616 Printed: 08 -18 -2010 J • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa. us Electrical Permit No. ILty— Go l tO Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print"' SITE LOCATION Site Address: 11521 E. MARGINAL WAY S. Tenant Name: COMPLETE OFFICE Property Owners Name: SAME Mailing Address: SAME King Co Assessor's Tax No.: 102-3024 — '70-7 b Suite Number: Floor: 1 New Tenant: ❑ Yes ❑..No City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: DOUG JARVIS Mailing Address: BOX 266 HOBART, WA. 98025 E -Mail Address: YELLOWHAIR3 cAOL.COM Day Telephone: (206) 396 -2856 City State Fax Number: (425) 432 -2513 ZiP ELECTRICAL CONTRACTOR INFORMATION Company Name: D.J. ELECTRIC AND CONSTRUCTION, INC. Mailing Address: BOX 266 HOBART, WA. 98025 Contact Person: D.J. ELECTRIC AND CONSTRUCTION, INC. E -Mail Address: YELLOWHAIR3@AOL.COM Contractor Registration Number: DJELECIO27L9 City State Zip Day Telephone: (206) 396 -2856 Fax Number: (425) 432 -2513 Expiration Date: Valuation of Project (contractor's bid price): $ 21,800 Scope of Work (please provide detailed information): INSTALL A 30 KVA TRANS. AND PANEL AND WIRE MEZZ. T.I. Will service be altered? m Yes ❑ No Adding more than 50 amps? m Yes ❑ No Type of Use: OFFICE Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: m Puget Sound Energy ❑ Seattle City Light ❑ Service Change ❑ Fire Alarm H:Wpplicetiona\Forms- Applications on Line12010 Applications \7 -2010 - Electrical Permit Application.doc Im Page 1 of 2 ❑ Remodel m Tenant Improvement ❑ Telecommunication ❑ Temporary Service J RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, fumace thermostat) $152.85 $8L90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, fumace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. CTO ' : Signature: Date: 08/02/2010 Print Name: Day Telephone: (206) 396 -2856 Mailing Address: BOX 266 HOBART, WA. 98025 City State zip IDate Application Accepted: S_ O Date Application Expires: a_) _ �' Staff Initials: H: ApplicerionslForms- Applicai ons On 1im12010 AppiicaaomV •2010 - Electrical Permit Application.doc bb Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1023049076 Permit Number: EL10 -0616 Address: 11521 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 08/02/2010 Applicant: COMPLETE OFFICE Issue Date: Receipt No.: R10 -01458 Initials: User ID: Payee: WER 1655 Payment Amount: $588.62 Payment Date: 08/02/2010 11:42 AM Balance: $0.00 D J ELECTRIC & CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10514 588.62 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 470.90 000.345.832.00.00 117.72 Total: $588.62 PAYMENT RECFIVFD doc: Receiot -06 Printed: 08 -02 -2010 INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUkWILA BUILDING DIVISION • 12-- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 6,10-0K Project: p 1 n OrCIC Type of Inspection: Address: 11 • Date Called: Special Instructions:. Ol� V n Rio. (� 'f � '\ Date Wanted: i/o7 Cc.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 6 viJ/vt Inspector: Z-7- Date: 0I07H REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0.0O'044 4 PERMIT NO.) CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Copps Type of Inspection: 76)3 Address: / G Date Called: Special Instructions: 11 Date Wanted: 2. ?1 15.,n. Requester: / Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: I,JsPfc-rcl) leVticDPri Inspector: ■_//7 Date: 07ZyIv n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit �0°O PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: j mks Type of Inspection: 700, Address: /1521 6 v:‘,./,/„ Date Called: Special Instructions: Date Wanted: 2, a- Requester: Phone No: 14 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 5)ot/fht goyAw eosetef Inspector: lit Date: 0‘571/0 2 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • PE 16 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0616 DATE: 08 -02 -10 PROJECT NAME: COMPLETE OFFICE SITE ADDRESS: 11521 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bt din ivision Public Works Fire Prevention Structural n Planning Division Permit Coordinator n 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08 -03-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) 111 Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 08-31 -10 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -26 -02 Contractors or Tradespeople Pry'ler Friendly Page • Electrical Contractor A business licensed by L81 to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company D J ELECTRIC li CONST INC 4254322513 Po Box 266 Hobart WA 98025 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601872945 Active DJELECI027L9 Electrical Contractor 6/29/1998 6/29/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DJENT * *022BT D J ENTERPRISES Electrical Contractor General Unused 1/30/1998 1/30/2000 Archived TRIWEE1051D4TR1 WEST ENTERPRISES INC Electrical Contractor General Unused 3/24/1995 3/24/2001 Archived MASTER ELECTRICIAN INFORMATION License JARVIVD96209 Name JARVIS, VIRGIL D Status Active Business Owner Information Name Role Effective Date Expiration Date JARVIS, VIRGIL D Violation Amount 01/01/1980 3/25/2010 JARVIS, VIRGIL D Agent 01/01/1980 $250.00 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 1 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 4/7/2000 Until Released Bond $4,000.00 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EMEHU03260 3/25/2010 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 08/18/2010 -45 kW /56kVA GENERATOR WiTH 80A -3P OUTPUT CIRCUIT BREAKER COMPLETE OFFICE TENANT SPACE -100A 3 -POLE ATS EXTG 200A FEEDER MAIN ELECTRICAL RM B 30 WA XFMR 30 kVA XFMR i:///j/ i 600A BUSSED GUTTER C/T 1ST FLOOR EXTG 80A FEEDER 18 CU 3/4 "C - 3 8 CU & 1 10 CU GND - 1 -1/4 "C - 413 CU & 1,8 CU GND FLAG NOTES EXTG 200A PANEL SERVING ADJACENT TENANT SPACE. EXISTING RISER DIAGRAM NOT TO SCALE SHADING INDICATES NEW WORK IN THIS CONTRACT. TO UTILITY CO. 1"-- TRANSFORMER EXISTING 600A SERVICE LOAD SUMMARY (PER NEC 220 CATEGORIES) 600A SERVICE DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND LOAD kVA AMPS ADJACENT SPACE (1008 OF PANEL RATING) COMPLETE OFFICE UGHTiNG RECEPTACLES - SPECIFIC USE RECEPTACLES - GENERAL USE** MOTORS LARGEST MOTOR LOAD HEATING COOUNG MISCELLANEOUS TOTAL 166.0 12.1 5.3 15.0 0.0 0.0 53.2 0.0 1.2 252.8 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA **DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 1.00 1.25 1.00 1.00 1.25 1.00 1.00 1.00 166.0 15.1 5.3 12.5 0.0 0.0 53.2 0.0 1.2 200 18 6 15 0 0 64 0 1 253.3 305 0 480Y/277V 3PH, 4W REVISIONS No changes shah be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions Will require a new Wan submittai and may include additional plan review fees. LIGHTING FIXTURE SCHEDULE TYPE DESCRIPTION INTERIOR F1 4' 2 -LAMP SURFACE MOUNTED FLUORESCENT STRIP WITH BATTERY BACK -UP BALLAST F2 8' 4 -LAMP SURFACE MOUNTED FLUORSCENT STRIP F3 PENDANT MOUNTED COMPACT FLUORESCENT FIXTURE WITH ACRYLIC DIFFUSER X1 EMERGENCY EXIT UGHT WiTH DUAL EGRESS HEADS LAMP WATTS /FIXT 2 -3278 62 4 -32T8 124 1- CFTR42 46 LED Lighting Summary 2008 Wagjdnaton ,State Nonresiderltail Energy gods comollgrlp4 Forma woe Ow My Project info project Address COMPLETE OFFICE Date 7/19/2010 11521 EAST MARGINAL WAY S. For Building Department Use I® 10 I® NCI I® IQ TUKWILA, WA Applicant Nana: CASE ENGINEERING Applicant Address: 10614 BEARDSLEE BLVD, STE C, BOTHELL, WA 98011 Applicant Phone: 425. 402 -9400 or A EMERGENCY Project Description IALTERATION OPEN STRIP EXIT UGHT COMBINATION DUAL HEAD 41104 K.:.] Compliance Option LIGHTING POWER ALLOWANCE Maximum Allowed Lighting Wattage (Interior) PANELBOARDS, SWITCHES & EQUIPMENT Location Occupancy Description Allowed W /SF Aron in ft2 Allowed x Area SINGLE -POLE DOUBLE -POLE THREE -WAY FOUR -WAY OCCUPANCY SENSOR LOW VOLTAGE OVERRIDE CEILING MOUNTED OCCUPANCY OCCUPANCY SENSOR POWER DAYLIGHT SENSOR OFFICE 1.00 3057 6 3057 ❑ PUSHBUTTON D DF .I n 0 ® ® SENSOR PACK CIRCUITING 0.0 ** From Tab, 15-1 (over) - document WWI exceptions on form LTG -WA Total Allowed Watts Proposed Lighting Wattage (Interior) 3057 IN CEIUNG OR WALL IN FLOOR OR UNDERGROUND CONDUCTORS HOMERUN CONTINUES ELSEWHERE (NOTED) ELECTRODE ISOLATED GROUND WIRING CONCEALED - - - WIRING CONCEALED -IN- NUMBER OF BRANCH CIRCUIT -3 BRANCH CIRCUIT GROUNDING Location Fbcture Description 1 of Fbduroe W /Fixt W Proposed ABOVE FINISHED FLOOR ALUMINUM AUTOMATIC TRANSFER SWITCH CIRCUIT CEILING CONDUIT ONLY COPPER DRINKING FOUNTAIN EXISTING FLOOR GROUND FAULT CIRCUIT INTERRUPTER GROUND T NT IN CONTRACT NL NIGHT LIGHT O.C. ON CENTER PNL PANEL p.o.s. POINT OF SERVICE PSE PUGET SOUND ENERGY PUD PUBUC UTILITY DISTRICT REC RECEPTACLES RQMTS REQUIREMENTS TBD TO BE DETERMINED TTB TELEPHONE TERMINAL BOARD WC WATER COOLER U.O.N. UNLESS OTHERWISE NOTED XFMR TRANSFORMER Fl -4' FLOURESCENT STRIP, 2 LAMP 7 62 CIRCUIT WiTH 434 ADDMONAL SYMBOLS F2.8' FLOURESCENT STRIP, 4 LAMP 1 124 . 124 F3- PENDANT MOUNTED COMPACT FLUORESCENT 40 46 1840 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2398 FILE COPY Permi# No.. tAiVrAAt Plan review approvai Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any I.: coke ' I .. Receipt of approved I: 4: BY did= if City s 1flkwIIa BUILDING DIVISION SEPARATE PERMIT RECTJNIED FOR: l§. Mechanical ❑ Electrical Plumbing Gas Piping City of Tukwila BI ILDJNG DIVISION DRAWING INDEX E0.1 RISER DIAGRAM, LEGEND, SCHEDULES E0.2 PANEL SCHEDULES E1.1 ELECTRICAL FLOOR PLANS RECEIVED AUG 02 2010 PERMIT CENTER ELLOOlollo D.J. ELECTRIC, INC P.O. BOX 256 HOBART, WA 98025 TEL 206 -396 -2856 FAX 425 - 432 -2513 tCASE ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425 -402 -9400 Fax: 425 -402 -9402 Project Title: Tenant Improvements for: COMPLETE OFFICE 11521 East Marginal Way S. Tukwila, Washington Sheet Title: RISER DIAGRAM, LEGEND, DETAILS & SCHEDULES Designed By: MSC Drawn By: CJP Project No: 10066 Date: 07/07/10 Sheet Number: E0.1 SYMBOL LEGEND POWER RECEPTACLE OUTLETS LIGHTING OUTLETS I® 10 I® NCI I® IQ DUPLEX DOUBLE DUPLEX SINGLE SPECIAL PURPOSE GFCI RECEPTACLE (VERIFY MOUNTING HEIGHT) FURNITURE SYSTEM POWER CONNECTION. CONNECT CONDUCTORS TO FURNITURE SYSTEM FLEX CONDUIT PROVIDED BY OTHERS. VERIFY REQUIREMENTS. JUNCTION BOX & CONDUIT FOR FURNITURE SYSTEM TELEPHONE /DATA CONNECTION COMBINATION POWER /DATA FLUSH FLOOR BOX DUPLE( OUTLET MOUNTED IN CEIUNG JUNCTION BOX WiTH BLANK COVER 0 SURFACE © RECESSED Q ' WALL MOUNTED RECESSED NIGHT UGHT 0) RECESSED MOUNTED DOWNUGHT DOWNUGHT FIXTURE EGRESS FIXTURE OR (NL) WALLWASHER /DIREC11ONAL FIXTURE FLUORESCENT EGRESS FLUORESCENT FLUORESCENT (CEIUNG OR UNIVERSAL MOUNT) EXIT /EMERGENCY EGRESS EMERGENCY EGRESS FIXTURE =ND SURFACE or A EMERGENCY I- -01 OPEN STRIP EXIT UGHT COMBINATION DUAL HEAD 41104 K.:.] 0 0 1' PANELBOARDS, SWITCHES & EQUIPMENT SWITCH OUTLETS & CONTROL DEVICES G CIRCUIT BREAKER PANEL SWITCHBOARD OR MOTOR CONTROL CENTER TERMINAL CABINET TRANSFORMER (SEE RISER DIAGRAM FOR SIZE) DISCONNECT SWITCH FUSED DISCONNECT SWITCH COMBINATION STARTER & DISCONNECT SWITCH FAN CONNECTION EQUIPMENT CONNECTION MOTOR CONNECTION S Sz S3 S4 Sur ® e ® SINGLE -POLE DOUBLE -POLE THREE -WAY FOUR -WAY OCCUPANCY SENSOR LOW VOLTAGE OVERRIDE CEILING MOUNTED OCCUPANCY OCCUPANCY SENSOR POWER DAYLIGHT SENSOR Se DIMMER S, PILOT- UGHTED SK KEY - OPERATED S. MASTER /iiiii 6 T ❑ PUSHBUTTON D DF .I n 0 ® ® SENSOR PACK CIRCUITING COMMUNICATIONS OUTLETS IN CEIUNG OR WALL IN FLOOR OR UNDERGROUND CONDUCTORS HOMERUN CONTINUES ELSEWHERE (NOTED) ELECTRODE ISOLATED GROUND WIRING CONCEALED - - - WIRING CONCEALED -IN- NUMBER OF BRANCH CIRCUIT -3 BRANCH CIRCUIT GROUNDING ■ TELEPHONE TELEPHONE /DATA ABBREVIATIONS AFF AL ATS CKT CLG C.O. CU DF EXTG FLR GFCI GND NIC ABOVE FINISHED FLOOR ALUMINUM AUTOMATIC TRANSFER SWITCH CIRCUIT CEILING CONDUIT ONLY COPPER DRINKING FOUNTAIN EXISTING FLOOR GROUND FAULT CIRCUIT INTERRUPTER GROUND T NT IN CONTRACT NL NIGHT LIGHT O.C. ON CENTER PNL PANEL p.o.s. POINT OF SERVICE PSE PUGET SOUND ENERGY PUD PUBUC UTILITY DISTRICT REC RECEPTACLES RQMTS REQUIREMENTS TBD TO BE DETERMINED TTB TELEPHONE TERMINAL BOARD WC WATER COOLER U.O.N. UNLESS OTHERWISE NOTED XFMR TRANSFORMER 11 -LV-- LOW VOLTAGE CIRCUIT WiTH ADDMONAL SYMBOLS . . _ REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC AUG 1 7 2010 . BUILDING D ISION SEPARATE PERMIT RECTJNIED FOR: l§. Mechanical ❑ Electrical Plumbing Gas Piping City of Tukwila BI ILDJNG DIVISION DRAWING INDEX E0.1 RISER DIAGRAM, LEGEND, SCHEDULES E0.2 PANEL SCHEDULES E1.1 ELECTRICAL FLOOR PLANS RECEIVED AUG 02 2010 PERMIT CENTER ELLOOlollo D.J. ELECTRIC, INC P.O. BOX 256 HOBART, WA 98025 TEL 206 -396 -2856 FAX 425 - 432 -2513 tCASE ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425 -402 -9400 Fax: 425 -402 -9402 Project Title: Tenant Improvements for: COMPLETE OFFICE 11521 East Marginal Way S. Tukwila, Washington Sheet Title: RISER DIAGRAM, LEGEND, DETAILS & SCHEDULES Designed By: MSC Drawn By: CJP Project No: 10066 Date: 07/07/10 Sheet Number: E0.1 IA t. 1.. 1.. 1.. 1. 1.. 1.. 1.. 1 /.. 1. 3444440111.1. 1.. 1.. t. 1.. 1.F1. 1.. 14 14 1.. 1.. 1.. to 1.. 1.. 1.. 1., 1a t. 'ii . 14 1.. 1a 1a 1.. t. 1.. 1.. t. 1., 14 t, . . 1a 1.. t. 1., 1.. ,a ., 1.. 1a 1.. 1.. 1.. 1a 1.. to t. 1.. 1.. 1.. .. 1.. ta 1.. 1a 1.. 1., A 1a 1., 1., 1.. 1.. 1., , a 1., 1., 1.. � Nom: .. 1., 1., 1a , 14 ,a ,a ,.. 1.. ,,a t. 1.. ,.. ,.. !.. 1.. ,a a., 1.. ,.. 1a 1a 1.. 1a 1.. ,.. 14 1a 14 1., 1.. ,a 1.. 1.. 1.. 1., I. 1. 1.. ,.. 13 t. 1a to t. t. 1.. ,.. t, t. to 1.. 1.. !.. 1.. 1.. 1a 1a 1.. 1a 1a A !.. ,a .. 1.. 1.. F1 F1 Egrcoo ath __!. Illuminance (F4) Average m 3.14 Maximum - 7.9 1 Minimum - 1.0 L Avg /Min Ratio Max /Min Ratio 3 7 .14 .90 1.. X1 r. L! 1 1 1 1 1 1 1 '■■ 11 12 EGRESS LIGHTING CALCULATIONS PLAN E(7)) _r NORTH Vi C -1,3 F2 CLASS RM F3 0 F30 F30 3d 3d 3d 0 �a0 X1 =1 F3 M y° o 1 F1 F3 F3 F3 F3 0 0 0 0 1b la la la F3 0 1b F3 0 F30 F30 3d 3d 3d 1 F3 F1 F3 0 0 1 a �ry is OPEN OFFICE F3 0 la F3 F3 F3 0a la 01a ZN'F-3 Q 0 F3 1 1 1 Fl F3 I lb(� 1 1 REV F NED .FOR Wini COMP . AN N NFPA 70 AUG 17 2010 OFFICE 3 3 , F3 Q F1 b 3b 1 F1 F3 Q F3 0 0 F3 3b 1 1 ukwiIa 4 .!vISON F30 F30 F30 3 3 3 SAMPLE tg 1 — ri UPPER FLOOR LIGHTING PLAN IL NORTH SCALE: 1/8" = 1' -0" GENERAL NOTES - LIGHTING 1. ALL CIRCUIT NUMBERS SHOWN REFER TO PANEL "C" UNLESS OTHERWISE NOTED. CLASS I� I 1 -= A -1.3.5 WP 110 41116)• NORTH UPPER FLOOR POWER /COMMUNICATIONS PLAN FLAG NOTES POWER VERIFY LOCATION PRIOR TO ROUGH —IN. ELlo Ololk' RECEIVED AUG 02 2010 PERMIT CENTER D.J. ELECTRIC, INC P.O. Box 256 HOBART, WA 98025 TEL 206 - 396 -2856 FAX: 425 - 432 -2513 CASE iv ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425- 402 -9400 Fax: 425 -402 -9402 Project Title: Tenant Improvements for: COMPLETE OFFICE 11521 East Marginal Way S. Tukwila, Washington Sheet rue: UPPER FLOOR ELECTRICAL PLANS Designed By: MSC Drawn By: CJP Project No: 10066 Date: 07/07/10 Sheet Number E1.1 PANEL SCHEDULE NUMBER A LOCATION: WAREHOUSE SERVING: COMPLETE OFFICE 480Y/277 VOLTS 3 PHASE 4 WIRE 200 AMP with MAIN LUGS CKT' N0. LOAD DESCRIPTION KVA TRIP AMPS 25* _ _, is ^ ^ ^ ^ ^ ^ ^ ^ ^ 80 - TRIP AMPS KVA TRIP AMPS _ 20 _ _ 40 _ KVA LOAD DESCRIPTION Cam' N0. 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 RTU -1 SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SUBFEED PANEL C 15.0 44.2 6.1 21.5 ROOFTOP HVAC ROOFTOP HVAC SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 WI/LUNCH RM ^_ ^ ^_ ^_ ^_ ^_ ^_ ^_ ^- •` • .. i-. ^_ 20 1.2 DISHWASHER 4 5 .. REMARKS: EXISTING PANEL ,*=PROVIDE BREAKER IN EXTG SPACE CONNECTED LOAD: 86.8 KVA 105 AMPS DEMAND LOAD: KVA AMPS LOAD SUMMARY. (PER NEC 220 CATEGORIES) PANEL A DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND kVA LOAD AMPS LIGHTING RECEPTACLES - RECEPTACLES - MOTORS LARGEST MOTOR HEATING COOUNG MISCELLANEOUS TOTAL SPECIFIC USE GENERAL USE** LOAD 12.1 5.3 15.0 0.0 0.0 53.2 0.0 1.2 86.8 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA * *DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 1.25 1.00 1.00 1.25 1.00 1.00 1.00 15.1 5.3 12.5 0.0 0.0 53.2 0.0 1.2 18 6 15 0 0 64 0 1 87.3 105 0 480Y/277V 3PH, 4W PANEL SCHEDULE NUMBER B LOCATION: WAREHOUSE SERVING: OFFICE LOADS 208Y/120 VOLTS 3 PHASE 4 WIRE 100 AMP with MAIN BREAKER Cam' N0. LOAD DESCRIPTION KVA TRIP AMPS TRIP AMPS KVA LOAD DESCRIPTION Cam' N0. 1 MAIN BREAKER LTS - UPPER FLR OPEN OFFICE LTS -- UPPER FLR CLASSRM SPACE SPACE SPACE LTS - WAREHOUSE SUBFEED - PANEL B 100 8.9 1.2 1.3 1.6 0.8 SUBFEED PANEL D SPACE SPACE LTS - OFFICE LTS - OFFICE LTS - OFFICE LTS - OFFICE ^20/20 1.5 WI/LUNCH RM 2 3 _ i-. ^_ 20 1.2 DISHWASHER 4 5 .. .. .. REMARKS: NEW PANEL ^20/20 1.1 REC - LUNCH RM /DISPOSAL 6 7 SPARE _ 20 ^ ^_ 20 0.2 BATHROOM 8 9 REC 0.6 20 ^ ^_ 20 0.4 REC 10 11 REC /REC 1.0 20/211^ ^20/20 0.4 REC /SPARE 12 13 REC /REC - CUBES 1.0 20/20!• •_ 20 0.2 REC - PHONE 14 ^20/20 15 REC 0.4 20 ^ 1.5 REC /COPIER 16 17 SPARE /REC - APC 1.0 30 ^ ^20/20 0.8 REC /SPARE 18 19 REC /REC - PHONE RM 0.6 20/211'"• ^.20/20 1.2 REC - GFI ROOF /REC - CUBES 20 21 REC /SPARE 0.4 20/2O" ^.20/20 1.6 HEAT /REC - CUBES 22 23 SIGN /SPARE 1.2 20 ^ 30 4.5 HOT WATER TANK 24 25 REC - CUBES /REC - CUBES 0.8 20/211'"` 26 ' 20 27 REC - CUBES /REC - CUBES 0.8 20/211^ SPARE 28 29 REC - CUBES /REC - CUBES 0.8 20/211^ 30 .• .. _-s .. REMARKS: EXISTING PANEL CONNECTED LOAD: 23.2 KVA 64 AMPS SHOWN FOR REFERENCE ONLY DEMAND LOAD: KVA AMPS LOAD SUMMARY (PER NEC 220 CATEGORIES) PANEL B DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND kVA LOAD AMPS LIGHTING RECEPTACLES - RECEPTACLES - MOTORS LARGEST MOTOR HEATING COOLING MISCELLANEOUS TOTAL SPECIFIC USE GENERAL USE ** LOAD 0.0 5.3 10.6 0.0 0.0 6.1 0.0 1.2 23.2 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA * *DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 1.25 1.00 • 1.00 1.25 1.00 1.00 1.00 0.0 5.3 10.3 0.0 0.0 6.1 0.0 1.2 0 15 29 0 0 17 0 3 22.9 64 0 208Y/120V 3PH, 4W PANEL SCHEDULE NUMBER C LOCATION: WAREHOUSE SERVING: COMPLETE OFFICE 480Y/277 VOLTS 3 PHASE 4 WIRE 80 AMP with MAIN LUGS Cam' N0. LOAD DESCRIPTION KVA TRIP AMPS 20* ^ 20* _^ T�j�j !T7 TRIP AMPS _ 50* _ ^_ 20 20 20 20 KVA LOAD DESCRIPTION Cam' N0. 1 3 5 7 9 11 13 15 17 LTS - UPPER FLR OPEN OFFICE LTS -- UPPER FLR CLASSRM SPACE SPACE SPACE LTS - WAREHOUSE SUBFEED - PANEL B 2.3 3.4 1.5 23.2 8.9 1.2 1.3 1.6 0.8 SUBFEED PANEL D SPACE SPACE LTS - OFFICE LTS - OFFICE LTS - OFFICE LTS - OFFICE 2 4 6 8 10 12 14 16 18 !-. ^ ^ 20 ^ 40 _ _ .-. .. ^_ ^_ ^_ ^_ .0 .. .. i-. .. .. .. ^ .. .. .. REMARKS: NEW PANEL REMARKS: EXISTING PANEL *= PROVIDE BREAKER IN EXTG SPACE CONNECTED LOAD: 44.2 KVA 53 AMPS DEMAND LOAD: KVA AMPS City of Tukwila BUILDS G DIVISION LOAD SUMMARY (PER NEC 220 CATEGORIES) PANEL C DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND LOAD kVA AMPS UGHTING RECEPTACLES - RECEPTACLES - MOTORS LARGEST MOTOR HEATING COOLING MISCELLANEOUS TOTAL SPECIFIC USE GENERAL USE** LOAD 12.1 5.3 15.0 0.0 0.0 10.6 0.0 1.2 44.2 *50* DEMAND ON GENERAL USE RECEPTACLES OVER 10 WA **DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 1.25 1.00 * 1.00 1.25 1.00 1.00 1.00 15.1 5.3 12.5 0.0 0.0 10.6 0.0 1.2 18 6 15 0 0 13 0 1 44.7 54 0 480Y/277V 3PH, 4W PANEL SCHEDULE NUMBER D LOCATION: WAREHOUSE SERVING: OFFICE LOADS 208Y/120 VOLTS 3 PHASE 4 WIRE 100 AMP with MAIN BREAKER CKT. LOAD DESCRIPTION KVA 20 _ 20 ^ 20 ^ 20 ^ 20 ^ 20 ^ 20 ^ 20 ^ 20 ^ ^ ^ ^ ^ ^ ^ ,-, T�j�j !T7 ^- 20 ^ 20 ^_ 20 _ 30 _ ^_ 20 ^_ 20 ■_ 20 ^_ 20 ^_ ^_ ^ ^_ ^_ ^_ .. KVA LOAD DESCRIPTION N�' 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 REC - CLASSROOM REC - CLASSROOM REC - SAMPLE ROOM SPARE SPARE SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE 0.8 0.8 0.8 0.8 1.0 0.2 4.5 REC - OPEN OFFICE REC - OFFICE REC - ROOF HOT WATER TANK SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 .. .. REMARKS: NEW PANEL CONNECTED LOAD: 8.9 KVA 25 AMPS DEMAND LOAD: KVA AMPS LOAD SUMMARY (PER NEC 220 CATEGORIES) PANEL D DESCRIPTION CONNECTED LOAD -kVA DEMAND FACTOR DEMAND kVA LOAD AMPS UGHTING RECEPTACLES - RECEPTACLES - MOTORS LARGEST MOTOR HEATING COOUNG MISCELLANEOUS TOTAL SPECIFIC USE GENERAL USE** LOAD 0.0 0.0 4.4 0.0 0.0 4.5 0.0 0.0 8.9 *50% DEMAND ON GENERAL USE RECEPTACLES OVER 10 kVA **DOES NOT INCLUDE RECEPTACLES FOR SPECIFIC EQUIPMENT 1.25 1.00 * 1.00 1.25 1.00 1.00 1.00 0.0 0.0 4.4 0.0 0.0 4.5 0.0 0.0 0 0 12 0 13 0 0 8.9 25 0 208Y/120V 3PH, 4W RECEIVED AUG 02 2010 PERMIT CENTER OLIO - O1OR D.J. ELECTRIC, INC P.O. BOX 256 HOBART, WA. 98025 TEL 206 - 396 -2856 FAX 425-432-2513 CASE Iv ENGINEERING Consulting Electrical Engineers 10614 Beardslee Blvd., Suite C Bothell, Washington 98011 Phone: 425 -402 -9400 Fax: 425- 402 -9402 Project Title: Tenant Improvements for: COMPLETE OFFICE 11521 East Marginal Way S. Tukwila, Washington Sheet Title: RISER DIAGRAM, LEGEND, DETAILS & SCHEDULES Designed By: MSC Drawn By: CJP Project No: 10066 Date: 07/07/10 Sheet Number: E0.2 •