Loading...
HomeMy WebLinkAboutPermit EL10-0621 - WESTFIELD SOUTHCENTER MALL - FRANCESCA'S COLLECTIONSFRANCESCA'S COLLECTIONS 611 SOUTHCENTER MALL EL1O-0621 Parcel No.: Address: Tenant Name: City.f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: //www.ci.tukwila.wa.us 9202470010 611 SOUTHCENTER MALL TUKW FRANCESCA'S COLLECTIONS ELECTRICAL PERMIT Permit Number: EL10 -0621 Issue Date: 09/16/2010 Permit Expires On: 03/15/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: KYLE KIMBERLAIN Address: 6939 MARINER DR #D , RACINE WI 53406 Contractor: Name: ARCHETYPE ELECTRICAL SERVICES Address: 20715 LARCH WY SUITE 3 , LYNNWOOD WA 98036 Contractor License No: ARCHEES915Q2 Phone: 262 - 886 -9800 Phone: 206- 730 -0897 Expiration Date: 12/04/2011 DESCRIPTION OF WORK: REUSE EXISTING WIRING, NEW LIGHTING AND NEW SWITCHES Value of Electrical Work: NRES: $7,500.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $287.63 National Electrical Code Edition: 2008 Date: 1���J� �V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: e l /) t ein 2 ✓1 Date: Cy/ 7/ 0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0621 Printed: 09 -16 -2010 • wq� City of Tukwila iDepartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: Suite No: Tenant: 611 SOUTHCENTER MALL TUKW FRANCESCA'S COLLECTIONS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0621 ISSUED 08/03/2010 09/16/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: �4 f_ ✓l. V� Date: l‘,/10 Print Name: Jq e doc: Cond -Elec ELI 0-0621 Printed: 09 -16 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. 0— o (p�-1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 61/ *t(14,7PVty,i //, 11 Tenant Name: d a CP5C�r S (',0itecle -14-S Property Owners Name: )es34-0i c2 & fLC p?foO yAu4I ceJ Mailing Address: King Co Assessor's Tax No.: 79? Suite Number: 5, 7‘,7 Floor: New Tenant: ....Yes ❑ .. No City If VI - State if /8e CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Li IQ Prikt Day Telephone: 02. — 0 oC� %r-6 Mailing Address: 69,' 3 otrr{ t e v r- y Reir9 s,.P City I �+ State Zip E -Mail Address: (yle eP 4,60/ S /ri' -v (� 145l/ rueke0t •eawt Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ r/ y� K��C�� t)w ` �UtJ Scope of Work (please provide detailed information): P (ASP e-e6t? ej t,t�crr'9vcj / )PS\e.. i-Seu� a�'1 rxw°IcLes Will service be altered? ❑ Yes IR No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added /altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 ELECTRICAL CONTRACTOR: Signature: Print Name: 6o r) a q ft r. y l 3/ g ilia,rh r•— Mailing Address: f t-e_ reiwt; tA4 aker, Date: g---5- k) Day Telephone: p? 7gea A`C k t tw. 53 !//4 City State Zip Date Application Accepted: f a Date Application Expires: Staff Initials: W` H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0621 Address: 611 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/03/2010 Applicant: FRANCESCA'S COLLECTIONS Issue Date: Receipt No.: R10 -01754 Initials: WER User ID: 1655 Payment Amount: $230.10 Payment Date: 09/03/2010 11:04 AM Balance: $0.00 Payee: RETAIL STORE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 4057 230.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 230.10 Total: $230.10 rNY MEW lcrgivFn doc: Receiot -06 Printed: 09 -03 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0621 Address: 611 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 08/03/2010 Applicant: FRANCESCA'S COLLECTION Issue Date: Receipt No.: R10 -01482 Payment Amount: $57.53 Initials: WER Payment Date: 08/03/2010 02:44 PM User ID: 1655 Balance: $230.10 Payee: RETAIL STORE CONSTRUCTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3926 57.53 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 57.53 Total: $57.53 PAYMENT RFOFIvpr. doc: Receiot -06 Printed: 08 -03 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION , 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: t Type of Inspection: Address: (« 1 ilikit Date Called: Special Instruction Date Wanted: /0/C m: ''R'e Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. OMMENTS: CorteknoAL5 evA>t ecV KAN./ Inspector: dr Date: /07</10 n REINSPECTION EE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367(0 Permit Inspection Request Line (206) 431 -2451 6,to- 06p Project: � • env r Type of Inspection: Address: 1. 411 'tilL- Date Called: Special Instructions: Date Wanted: fo Er;ii Requester: Phone No: ❑ Approved per applicable codes. COMMENTS: Corrections required prior to approval. + j, nl( g.Ot 5.04 Mc. 5 J Pokr tAj C,Fit t41 LAAt't._ phdoat hem Rte-i 6 (seDAW6cr tAt rm Tryawf isitites (.0 1 5 Coy IJTC-(L R Ea-PTA-ME SC-4 6,5 4iNip .14 PR, IZS e /5 AP° r1C- - <R f�Jti -p cy 6, o 5IIJI • M O46401 uQ '5 TD 8( OA) mcn+ d/\ t LJc tPTTnIGI Ct2NIt" ®iR` t IE fe.A urrq't"} - klytivrf Q Sr mot is - /W t(C. To RE 5tI VPDRX t )r -vi 12 " aF go) tap /tea �z rteT n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Date: in(/ 3 o 1 INSPECTION RECORD Retain a copy with permit CU' UPZ-I INSPECTION NO. PERMIT NO. C.-- CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: / OrC C 5 ■ Type of Inspection: 700 Address: 11 flew Date Called: Special Instructions: Date Wanted: Zy a - C Requester: Phone No: ❑ Approved per applicable codes:. • • a Corrections required prior to approval. COMMENTS: taklith biA 5-or-Fri I 4ovitcpup Inspector: aliWeP\ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 09A(1/0 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July2007 Project Info Project Address soDTH ciarrER Date 7/14/2010 SEATTLE, WA For Buildi a artment Use I L E C -p) a r"l?6t o. 9 6`� PROJECT NAME: FRAMCESCAS Applicant Name: KATHLEEN XOLBECX Po ApplicantAddress: 50th SOUTH SIXTH STE /SUITE 1100 MPLS, MN 55402 1692.0 Applicant Phone: 612.465.7550 Project Description 7, New Building Addition • Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 1248.0 1872.0 ■ No changes are being made to the lighting C - Track Lights On Current Limiters & space use not changed. • Less than 60% of the fixtures new, installed wattage not increased, Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area 1 RETAIL 1.50 1692.0 2538.0 2 Track Lighting Merchandise Display 1.50 1248.0 1872.0 SALES C - Track Lights On Current Limiters 1 2400.0 2400.0 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 4410.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed BACRROOM Al 1X4 Fluorescent lay -in 2 -lamps T8 32W 3 58.0 174.0 BATHROOM Al 1X4 Fluorescent lay -in 2 -lamp T8 32W 1 58.0 58.0 SALES C - Track Lights On Current Limiters 1 2400.0 2400.0 B- wall Sconce 3 30.0 9 0 .0 B -1 Chandelier 2 149.0 298.0 SALES FURNITURE DISPLAY 6 50.0 300.0 D- 8 18.0 144.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3464.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2.For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and REVIEW • a• s sp: cified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference CO- - . " -1 Iso b used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as (juM i� ge of current limiting devices or of the transformer. NFPA' s. -.r exempt lighting, note section and exception number, and leave Watts/Fixture blank. AUG 2 0 2010 City of Tukwila BUILDING D VISION EL1OOl RECEIVED AUG 03 2010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential EnergyCode Compliance For Revised July2007 Prescriptive Spaces Occupancy. 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Lighting • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" and Fixtures: fixture answer is checked, the number of (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector fixtures in the space is not limited by Code. 1521) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- Clearly indicate these spaces on plans. If tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. not qualified, do LPA Calculations. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance PA Use' L LPA (W /sf) U Use' L LPA2 (W /sf) -1 Unit Lighting Power Allowance PA Use' L LPA (W /sf) U Use' L LPA2 (W /sf) Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter -height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. ROUTING SLIP ACTIVITY NUMBER: EL10 -0621 DATE: 08 -03 -10 PROJECT NAME: FRANCESCA'S COLLECTIONS SITE ADDRESS: 611 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: laing Division ir° Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 08-05-10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09-02 -10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ARCHETYPE ELECTRICAL SERVICES 2067300897 20715 Larch Way, Suite 3 Lynnwood WA 98036 Snohomish Individual UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602196548 Active ARCHEES915Q2 Electrical Contractor 12/4/2009 12/4/2011 General Unused MASTER ELECTRICIAN INFORMATION License HOLLIJ *961MH Name HOLLIMAN, JOEL Status Active Business Owner Information Name Role Effective Date Expiration Date HOLLIMAN, JOEL E Owner 11/22/2009 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 American Contractors Indem CO 100106281 12/04/2009 Until Cancelled $4,000.00 12/04/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni /bbip /Print.aspx 09/16/2010 POKER GENERAL NOTES: A. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. B. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU— WIRING" WHERE AND WHENEVER POSSIBLE. C. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. D. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101' -0" TO 150' -0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 151' -0" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. ALL WIRE TO BE COPPER. E. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. — CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS AND AT 18" A.F.F. UNLESS OTHERWISE NOTED). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANTS PROJECT MANAGER PRIOR TO ROUGH —IN. F. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. G. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH TENANTS PROJECT MANAGER PRIOR TO ROUGH —IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY —IN CEILINGS ARE ACCEPTABLE. H. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S SPECIFIC FIRE ALARM VENDOR "PERFORMANCE SYSTEMS INTEGRATION ". IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE —IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. I. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT SWITCH IN LANDLORD'S SWITCHGEAR WITH DEMISED PREMISES' SPACE NUMBER. J. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK. K. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. L. ELECTRICAL CONTRACTOR IS TO ROUTE POWER AND DATA IN 2" SLAB DEPRESSION. (CORE DRILL ON ELEVATED FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH LANDLORD PRIOR TO STARTING WORK. M. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORIES IN ALL PANELBOARDS. N. ALL RECEPTACLES TO BE MOUNTED VERTICALLY, NOT HORIZONTALLY. 0. "GC IS TO REVIEW STRUCTURE BELOW OUR SPACE PRIOR TO CONSTRUCTION FOR CONDITIONS PREVENTING FLOOR PENETRATIONS AS SHOWN. OBSTRUCTIONS THAT PREVENT LAYOUT AS SHOWN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATI L-Y AND PRIOR TO FRAMING." P. EXPOSED THEFT PREVENTION DEVICES ARE NOT PERMITTED TO c3E INSTALLED WITHOUT SPECIFIC LANDLORD REVIEW AND APPROVAL OF SHOP DRAWINGS. Q. AUDIBILITY TESTS BY THE SEATTLE FIRE DEPARTMENT ARE ONLY SCHEDULED FOR 6:00 AM ON MONDAYS OR FRIDAYS, DUE TO SFD REQUIREMENTS. POKER PLAN KEYED NOTES 10 I I 12 EXISTING SPLIT SYSTEM WITH AIR HANDLER * ELECTRIC DUCT HEATER. MAINTAIN CONNECTION. COORDINATE WITH MECHANICAL. EXISTING EF —I, 120V /IPH. MAINTAIN CONNECTION. DUPLEX RECEPTACLE WITH COVERPLATE MOUNTED IN SOFIT ABOVE WINDOW. CONTROL RECEPTACLE WITH TIMECLOCK AND SWITCHES AT MANAGER'S DESK. RECEPTACLE AND COVERPLATE TO MATCH SURROUNDING NALL COLOR. EXISTING TO REMAIN 120/208 3 PHASE PANEL 'L'. SEE E3 FOR FURTHER INFORMATION. PROVIDE GFI RECEPTACLE FOR WATER COOLER. COORDINATE EXACT LOCATION WITH ARCHITECTURAL. 2' X 4' X 3/4" TELECOMM. BOARD WITH DEDICATED QUADRAPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. EXTEND I" TELEPHONE CONDUIT WITH PULLNIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELECOMM. BOARD. VERIFY EXACT LOCATION IN FIELD. RECEPTACLE, DATA AND TELEPHONE OUTLET MOUNTED IN CASHWRAP MILLWORK. COORDINATE EXACT PLACEMENT OF DEVICE AND WIRE ROUTING IN CASHWRAP WITH MILLWORK DRAWINGS. (1) I" CONDUIT FOR POWER AND (2) 1" CONDUITS FOR TELEPHONE /DATA UNDERFLOOR FROM CASHWRAP TO NEARBY WALL OR COLUMN, UP TO ABOVE CEILING AND TO ELECTRICAL PANEL OR TELEPHONE BOARD AS LABELED. STUB CONDUITS UP 16" ABOVE FINISHED FLOOR AT CASHWRAP. PROVIDE NEW WATER HEATER. PROVIDE CONNECTION TO EXISTING PANEL 'L'. COORDINATE EXACT LOCATION WITH MECHANICAL. PROVIDE 8' -3" WHIP FOR FURNITURE. COORDINATE EXACT PLACEMENT OF DEVICE AND WIRE ROUTING WITH MILLWORK DRAWINGS. PROVIDE 1' -3" WHIP FOR FURNITURE. COORDINATE EXACT PLACEMENT OF DEVICE AND WIRE ROUTING WITH MILLWORK DRAWINGS. MAINTAIN CONNECTION TO EXISTING INSTANTANEOUS WATER HEATER. COORDINATE EXACT LOCATION WITH MECHANICAL. ELECTRICAL LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION MOUNTING HGT. TO CENTERLINE UNLESS OTHERWISE NOTED 0 -0 - 0 0 WP • ... $2 $3 $4 MS 4D 4 DE CEILING OUTLET WALL OUTLET BLANKED OUTLET WIRED JUNCTION BOX CEILING MOUNTED EXIT LIGHT CEILING MOUNTED EXIT LIGHT OUTLET NALL MTD. EXIT LIGHT W/ DIRECTIONAL SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS ARROWS SEE DRAWINGS DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE FLOOR MOUNTED "DOGHOUSE" GFI RECEPT. DUPLEX RECEPTACLE, WEATHERPROOF DUPLEX RECEPTACLE, GROUND FAULT PROTECTED DUPLEX RECEPTACLE, QUADRAPLEX RECEPTACLE, QUADRAPLEX RECEPTACLE TOGGLE SWITCH, SINGLE POLE TOGGLE SWITCH, DOUBLE POLE TOGGLE SWITCH, 3 —WAY, 4 —WAY MANUAL MOTOR STARTING SWITCH MAGNETIC MOTOR STARTER COMBINATION STARTER /SAFETY SNITCH SAFETY SWITCH ELECTRIC PANEL MOTOR OUTLET TIME CLOCK 18" FLOOR IS" 18" ISOLATED GROUND 18" 18" 481 48" 48" 48" AS REQUIRED AS REQUIRED AS REQUIRED 6'-0" TO TOP AS REQUIRED • <E1 -E1 0 0 0 FS T5 1 PHONE JACK (JACK = GRAY) 1 PHONE JACK WITH 2 PHONE LINES (JACK = BLUE) 2 DATA OUTLETS, I PHONE JACK (JACK = ORANGE AN D DATA OUTLET (X) = AMOUNT OF DATA JACKS (JACK 1 PHONE JACK DEDICATED TO FAX (JACK = BLACK) CASH REGISTER DATA SIM (JACK = PURPLE) (1) DATA JACK FOR DSL FIRE ALARM BREAK STATION FIRE ALARM AUDIO /VISUAL SIGNAL DEVICE DUCT MTD. SYSTEM SMOKE DETECTOR W/ REMOTE INDICATORS FIRE ALARM WATER FLOW SWITCH FIRE ALARM TAMPER SWITCH P SYSTEM SMOKE DETECTOR, PHOTOELECTRIC SYSTEM HEAT DETECTOR SYSTEM HEAT DETECTOR (FIXED TEMP.) FIRE ALARM PANEL JUNCTION BOX DUPLEX RECEPTACLE AT STOREFRONT DELIVERY BUZZER DELIVERY BUZZER PUSHBUTTON DELIVERY BUZZER TRANSFORMER MULTI— OUTLET RACEWAY CEILING SPEAKER CURRENT LIMITER H 135 IFACH 0 l' Dig GRAY) = ORANGE) 48" 96" AS REQUIRED AS REQUIRED AS REQUIRED CEILING MTD. CEILING MTD. CEILING MTD. AS REQUIRED AS REQUIRED CEILING MTD. AS REQUIRED 54" AS REQUIRED AS REQUIRED CEILING MTD. AS REQUIRED PNL 'L' 0 SEPARATE PERMIT REQUIRED FOR: irMechanical plectricid Plumbing rein PiPhe City of Tukwila Epla. f :',I ;G DIVISION No changes shall n e to the scope work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may indude additional plan review fees. (Q) FILE COPY Permit No. E1.'�' Plan review approval is subject to enors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and cations is acknowledge ®y--- - Date: /1A/ L r� City Of Tukwila BUILDING DIVISION L 10 R ❑DELE`D /RESTR ❑ ❑M 3 5 L —I2 L -14 EX. STOCK L -27 ROOM 2 L -12 NEW SALES AREA 1 EDH— I 18" 8" O 0 O 0 L -18 L 21 L —17 VIA SW. "e" 18' L-2,4 L -6 L 18 L -18 REVIEWED FOR COMPLIANCE WIT A70 -NEC AUG 2 0 2010 ILDING DIVISION ISION DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering MBA Architects, Inc. 3823 Creekside Lane Holmen, WI 54636 608 - 785 -2760 FAX:608- 785 -2750 http://www.mba-architects.com PROJECT NAME: FRANCESCA'S COLLECTIONS PROJECT ADDRESS: SOUTH CENTER MALL TUKWILA, WA CLIENT NAME: FRANCESCA'S COLLECTIONS l e5Ca'5 4' -r el 0 L ,, ' : C T 11 0 14 S PROJECT MANAGER: DATE 6/29/10 7/7/10 7/14/10 8 0 0 REVISION ! COMMENTS X X MALL REVIEW X X FINAL REVIEW X X X PERMIT ELlO o&zl ELECTRICAL POWER PLAN El 1/4' -1' -0' RECEIVED AUG 0 3 2010 PERMIT CENTER IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE GALL THE ELECTRICAL DESIGNER. DESIGNER: ANTHONY GARGHED I : 612 -465 -7686 Drawn Bv: AC I Checked Bv: RM THIS SHEET CONTAINS: ELECTRICAL POWER PLAN 0411995 -012 LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION /MANUFACTURER MODEL NUMBER LAMP WATTAGE MOUNTING 1X4 DIRECT - INDIRECT / LIGHTOLIER -DI G S14 232 WPR AMW EB2 UNV 4' FLORESCENT 2 -32W 58 RECESSED CEILING GRID L -5 SALES LIGHTS L -7 SALES LIGHTS L -9 SALES LIGHTS A -2 L -17 SALES FURNITURE DISPLAY LIGHTS 1X4 DIRECT - INDIRECT / LIGHTOLIER -DI G S14 232 WPR AMW EB2 UNV W/E BALLAST NIGHT LIGHT 4' FLORESCENT 2 -32W 58 RECESSED CEILING GRID A -2E WALL SCONCE/ CRISTEL DE LISBON INCANDESCENT CANDELABRA 2 15W 30 WALL © 82" AFF B -1 B -2 CHAIN HUNG CHANDELIER / CRISTEL DE LISBON INCANDESCENT CANDELABRA 9 60W & 2 7W 554 CHAIN HUNG ® 7' -6" AFF TRACK /LITON -LP -1 CCT TRACK CHANNEL CL- CURRENT LIMITER /LITON -LPC 991, 992, 993 (AMP AS SHOWN) C - TRACK HEAD /LITON- LTF8G24 -CFL FLAT BIACK W /REFLECTOR MAX LITE MLS13GUWW GU24 SPIRAL 18 TRACK MOUNT ® 11 -0" AFF �p 6" RECESSED DOWN LIGHT / LITON-LH276-18E 1 18W CFL DTT /TTT 18 RECESSED ' LIGHTOLIER #E118NT6W - EMERGENCY LIGHTING 2 HEAD UNIT W/ BATTERY BACKUP MR16 _ SEE PLAN - MOUNT ON WALL OR CEILING. EM ®X LIGHTOLIER #LLNURW - LED EXIT WITH EMERGENCY BATTERY BACK UP LED _ SEE PLAN - MOUNT ON WALL OR CEILING. LIGHTING FIXTURE SUPPLIER: COORDINATE WITH OWNER. INDICATES FIXTURE TYPE x L7-7(x-c---INDICATES CIRCUIT NUMBER O L ax N INDICATES SWITCH CONTROL GENERAL NOTES THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE "THRU -VI IRING" WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "TI-RU - WIRING ". ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. 4. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY TENANT. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE TI-4E ADJUSTAB I LITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. LIGHT FIXTURE SPECIFICATIONS MAY VARY. IF CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR IS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH TENANTS LIGHTING SUPPLIER. 5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). CLOSELY COORDINATE INSTALLATION WITH TENANTS CONSTRUCTION MANAGER. 6. ALL LIGHTING CIRCUITS UP TO 100' -0" IN LENGTH SHALL UTILIZE #I2 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 101' -0" TO 150' -0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS 151' -0" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRYWALL CEILINGS ARE USED IN TINE "SALES" AREA, TI-IE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH TENANTS PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 9. EXIT /EMERGENCY LIGHTS AT STOREFRONT ARE TO BE CEILING MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.O.). EXIT /EMERGENCY LIGHTS AT DOOR TO "NON- SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH TENANTS CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. 10. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. SECURE PULL STRING AT BOTH ENDS OF CONDUIT. 11. LAMP COLOR TEMPERATURES SHALL BE 4100 DEGREES KELVIN OR ABOVE WITH A COLOR RENDERING INDEX (CRI) OF 80 OR MORE. TENANT SHALL USE LAMP TYPES WHICH ARE ENERGY EFFICIENT, LONG LIFE, AND CONTAIN LOW /NO MERCURY CONTENT. TENANT IS RESPONSIBLE FOR REPORTING ALL LIGHTING PURCHASES TO LANDLORD AS REQUESTED BY LANDLORD. LIGHTING PLAN KEYED NOTES Oi PROVIDE JUNCTION BOX WITH DISCONNECT SWITCH IN ACCESSIBLE AND CONCEALED LOCATION FOR CONNECTION TO STOREFRONT SIGN AND LIGHTING. LOCATE DISCONNECT PER NEC 600.6. TENANT'S ELECTRICIAN SHALL COORDINATE WITH SIEMENS ON BOTH SIGNAGE AND LIGHTING CONTROLS PER LANDLORD'S DESIGN CRITERIA. O CIRCUIT NIGHT, EMERGENCY, AND EXIT LIGHTING FIXTURES AHEAD OF CONTROLS. PER CODE REQUIREMENTS. 0 BOTH FIXTURE TYPES "B" AND "B -1" HAVE LABELED SOCKETS BY THE MANUFACTURER: "15 WATTS MAX" TO LIMIT" THE WATTAGE OF TI-4E FIXTURE AS REQUIRED. O EXISTING FIXTURE IN THE TOILET ROOM IS TO REMAIN. E.C. SHALL CLEAN AND RE -LAMP FIXTURE AS REQUIRED. PROVIDE A 24 HOUR 7 DAY TIME CLOCK TO CONTROL SIGN, STOREFRONT LIGHTING AND STOREFRONT RECEPTACLES. NOTE TO BIDDERS/CONTRACTOR THESE DRAWINGS WERE PREPARED AS ACCURATELY AS POSSIBLE UTILIZING EXISTING DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO THE BIDDING AND COMMENCEMENT OF THE PROJECT. CLAIMS FOR EXTRAS RESULTING FROM LACK OF COMPLIANCE WILL BE DENIED. A.D.A. NOTES LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL NAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, TI-4E MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. a b c d e f n L -13 STOCK ROOM LIGHTS L -5 SALES LIGHTS L -7 SALES LIGHTS L -9 SALES LIGHTS L -11 SALES DECORATIVE LIGHTS L -17 SALES FURNITURE DISPLAY LIGHTS CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" SWITCH BA\ \TS. 0 TORK #A502 HW GENERAL LTG CONTRACTOR TO VERIFY EXACT CONFIGURATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" SWITCH BA \K \TS. (6) L -11 VIA SW. "d" PNL 'L' L -13 VIA SW. "f" IL A -2E L -131\ L EM L -13 A -2 L -13 A -2 L -13 L -13 L -9 B -1 L -11 VIA SW. "c" �0 0 0 0 0 0 ■ 0 0 5A C(10) L- 9 12' -C" C(8) L -9 12 -0" D D D B -1 L -11 -� B -2 O L -11 EM O3 9-2 D 4 (5.) .• 7 ' -0" FI- -I? L -7 4 8' -0" C 6 8' -0" 3 L1 L(6) / 8, -0" 1 0 D 8' -50" 0 0 0 0 0 10 0 0 0 as 0 0 v at v v v ,v v v C(5 L —.` fl L- 12'-0" d C6 4 L- 8' -0" 4 4 C( 5) L- 5 r 1 C(4) L -5 C( 4 L 8' -O" 8' 0" C(6 1- C6 8' -O" 8' -0„ 0 0 0 0 1 a 0 0 0 0 0. 0 0 DODODOD -3 -3 0 L=3 LD3 L -1 1 ELECTRICAL LIGHTING PLAN E2 ELtOO ijpZI REVfE C FOR NFPA70 -NEC AUG 2 0 2010 jty ' . 1 1a BUILDING DIVISIO DUNHAM Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering MBA Architects, Inc. 3823 Creekside Lane Holmen, WI 54636 608 - 785 -2760 FAX:608- 785 -2750 http://www.mba-architects.com PROJECT NAME: FRANCESCA'S COLLECTIONS PROJECT ADDRESS: SOUTH CENTER MALL TUKWILA, WA CLIENT NAME: FRANCESCA'S COLLECTIONS ' C 0 1.. L ,E C T II O,; S PROJECT MANAGER: DATE 8 8 0 REVISION ! COMMENTS 6/29/10 X X MALL REVIEW 7/7/10 X X FINAL REVIEW 7/14/10 X X X PERMIT RECEIVED AUG 032010 PERMIT CENTER IF YOU HAVE ANY QUESTIONS REGARD I NS THE ELECTRICAL PLANS PLEASE GALL THE ELECTRICAL DES I SNER. DES I SNER: ANTHONY GARGHED I : 612- 465 -1686 Drawn Bv: AC Checked By RM THIS SHEET CONTAINS: ELECTRICAL LIGHTING PLAN 0411995 -012 E2 Panel : L Volta e: 120/208V, 3PH, 4W No. Am Note Description Ph Code L Cade C Code R Code M Code E Code K Code D 6.1 REGEPTAGLES 6.8 1.0 6.8 HVAG a.3 1 20/1 KITCHEN EGUIPMI =NT SIGN -A- 1200 ELEC.. MEAT 5.0 5.0 3 20/1 GRAND TOTAL LIGHTING- (STORE FRONT) -B- 144 SERVICE SIZING LOA TOTAL DEMAND LOAD: 253 = 25.3 KVA 11111 ® 2OeV /3PH = 12 AMPS ,11111 5 20/1 X11111 _____11111�� X11111 X11111 TRACK LIGHTING - (DISPLAY) -C- 800 ,: 7 20/1 TRACK LIGHTING- (DISPLAY) -A- 800 9 20/1 TRACK LIGHTING- (GENERAL) - B - 800 11 20/1 DECORATIVE LIGHTING - C - 388 13 2011 STOCK/REST ROOM LTS & EF -1 -A- 174 100 15 2071 TOILET ROOM RECEPTACLE -.B- 180 17 20/1 SALES FURNITURE - C - 600 19 2071 CEILING RECEPTACLES -A- 360 21 2011 NEW WATER HEATER - B - 1500 23 2071 ENS11NG WATER HEATER -C- 1200 25 20/1 SPARE - A - 27 • 20/1 BACKROOM WATER COOLER -B- 1000 29 2011 SPARE - C - 31 - SPACE - A - 33 - SPACE - B - 35 - SPACE - C - 37 - SPACE -A- 39 - SPACE - B - 41 - SPACE - C - 2 2011 I.G. REC - CASH REGISTER #1 - A - 500 •4 2071 I.G. REC - CASH REGISTER #2 -B- 500 6 2071 BACK OF CASHWRAP RECEP -C- 180 8 -I- 2011 BACKROOM DESK RECEPTACLE -A- 360 • PHONE BOARD -B- 360 12 2011 BACKROOM GENERAL RECEPTACLES -C- 540 14 20/1 BACKROOM REFRIGERATDR/MICROWAV -A- 1800 16 2011 SALES RECEPTACLE -B- 540 18 20/1 SALES RECEPTACLE -C- 540 20 50 CONDENSING UNIT-1 - A - 22 / U -B- 24 3 " -C- 2fi 30 DUCT HEATER -1 -A- 2704 2s / 'A - B - _____ 2700 30 3 0 - C - 2700 32 20/1 SPARE - A - 34 20/1 SPARE -B- 2071 AIR HANDLER -1 -C- 1100 38 - SPACE - A - 40 - SPACE - B - 42 - SPACE - C - Through Feed Connection - - :±: Lug None - B - ______ ______ ______ ________ ______ ______ ______ - - C - Main Breaker " 100 -A,- 2174 360 2660 100 2700 I -B- 944 1080 3000 2700 3 - C - 1788 1260 1200 1100 2700 Breaker Notes: Conn KVA phase loads Total - A - - B - -C - 1 - PROVIDE LOCK -ON DEVICE 1 23.8 8.0 7.7 8.0 2 - PROVIDE LOCK -OFF DEVICE Dmd Conn Panel - Bus KVA loads 3 - 6.1 4.9 Code L .'Lighting j I 4 - I 2.7 2.7 Code C - Convenience Receptacles (1 80 W) _.2:_ I 6.9 6.9 Code R - Receptacles (Non Convenience) Panelboard Notes: 1.5 1.2 Code M - Motors Largest motor VA' 1100.0 1 - PROVIDE ISOLATED GROUND BAR 8.1 8.1 Code E - Electric Heat , 2 - Code K - Kitchen Equip IDemand 100% 3 - ! Code D - Dwelling Units (Hotel/Motel Rooms) _±::_ 5 - 25.3 23.8 Total KVA E + Spare KVA ' %Spare E)4S1ING : Mounting 25 Adjusted KVA (Demand KVA + Spare KVA) ENS11NG : Amps AIC Rating 70 Adjusted Demand Amps ENSTING : Amp Rating of Bus 72 High Phase Demand Amps 1 7- Jul -10 100 : Panel Amp Rating in Miain or Bus Rating) File Name: Project Number : Project Name: 208 • : Phase to Phase Voltage PANEL L 411995 -006 FRANCESCAS GENERA NOTES A.Q.A. NOTES LANDLORD CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE laa3 (OR LATEST ADOPTED) NATIONAL ELECTRICAL GORE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ETRICAL REQUIREMENTS OF ALL EQUIPMENT ELC PROVIDED BY OTHERS (INCLUDING HVAG EQUIPMENT) PRIOR TO ROUGH -IN AND PROVIDE ALL REQUIRED FUSIBLE SWITCHES, TRANSFORMERS, STARTERS NECESSARY FOR PROPER OPERATION OF EQUIPMENT. DUPLEX RECEPTACLES MOUNTED WITHIN 6 FT. OF SINK TO BE A GFI RECEPTACLE. ALL WIRING SHALL BE COPPER, THHN/THWN OR XHHW INSULATED IN CONDUIT. MINIMUM CONDUIT SIZE TO BE 1/2". PROVIDE INSULATED COPPER BOND WIRE ON ALL G I RGU I TS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMMODATE LIGHT FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING AUTHORITY. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 4S' AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH 15 OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REDUCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25" FROM THE WALL BENEATH A CONTROL. VENDOR LOA1D T i' E CONNECT. (KW) DEMAND FACTOR DEMAND (KW) LIGHTING 4.q 1.25 6.1 REGEPTAGLES 6.8 1.0 6.8 HVAG a.3 I.0+ 9.6 KITCHEN EGUIPMI =NT O 0.65 O ELEC.. MEAT 5.0 5.0 _____hill _1111, GRAND TOTAL 23.8 25.3 SERVICE SIZING LOA TOTAL DEMAND LOAD: 253 = 25.3 KVA 11111 ® 2OeV /3PH = 12 AMPS LANDLORD PERMITS CONTRACTOR VENDOR 4' © © ©11 _____hill _1111, 11111 ,11111 X11111 _____11111�� X11111 X11111 ,: DIVISION 16000 - ELECTRICAL SECTION 16001 - BASIC ELECTRICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16000. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 16002 - GENERAL REQUIREMENTS A. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR TENANT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE TENANT PROJECT MANAGER, AS REQUIRED. B. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. C. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. D. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCESS PANELS FOR SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. E. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. F. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 16003 - CODES A. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY TENANT TO THE CONTRACTOR. SECTION 16004 - LICENSES, PERMITS, INSPECTIONS & FEES A. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. B. FURNISH TO TENANT'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 16005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS A. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY TENANT'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. B. ELECTRICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR TENANT'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. SECTION 16006 - GUARANTEE A. TI-HS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY TENANT'S PROJECT MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. B. TENANT SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY TENANT AND TENANT'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. SECTION 16007 - RECORD DRAWINGS A. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: 1. LOCATION OF CONCEALED CONDUIT AND WIRING. 2. LOCATION OF JUNCTION BOXES. 3. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. 4. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. B. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED TO TENANTS' PROJECT MANAGER. SECTION 16008 - DISCREPANCIES IN DOCUMENTS A. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEM. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE TENANTS' PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, TENANTS' PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SECTION 16009 DEMOLITION A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. B. ELECTRICAL CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING LIGHT FIXTURES, RECEPTACLES, SWITCHES, ETC. NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED CONDUITS OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND TENANT PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND TENANT. ALL UNUSED EXISTING PLENUM RATED CABLING IS TO BE REMOVED COMPLETELY. SECTION 16010 - CUTTING AND PATCHING A. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. B. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FINISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND TENANT'S PROJECT MANAGER. C. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGER. SECTION 16011 - SLEEVES A. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. C. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. SECTION 16012 - HANGERS A. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC. NECESSARY FOR THE INSTALLATION OF WORK. B. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT CONDUIT OR BOXES, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. DIVISION 16200 - ELECTRICAL SECTION 16201 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR REASONABLY IMPLIED AND INCIDENTAL TO THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEM AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. WORK IN THE LANDLORD'S MAIN DISTRIBUTION EQUIPMENT ROOM SHALL BE AS INDICATED, AND /OR REQUIRED, BY EXTENDING SERVICE TO THE LEASED SPACE. 2. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 3. COMPLETE LIGHTING FIXTURE INSTALLATION. 4. COMPLETE TELEPHONE CONDUIT SYSTEM, INCLUDING SERVICE CONDUIT FROM POINT OF CONNECTION TO LANDLORDS SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. 5. TEMP.ORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION. 6. WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER. 7. PROVISIONS FOR FIRE ALARM /SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORDS SYSTEM (IF APPLICABLE). 8. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 9. TESTING OF ALL ELECTRICAL EQUIPMENT. 10. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. B. PROVIDE ELECTRICAL SERVICE AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE LANDLORD AND THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY COMPANY FOR INSTALLATION OF METERING AS REQUIRED BY THE LANDLORD. C. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT (IF REQUIRED BY LANDLORD OR LOCAL CODE) FOR TELEPHONE SYSTEM WITHIN THE LEASED SPACE. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. D. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. SECTION 16202 - MATERIALS A. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. B. CONDUIT SHALL BE STANDARD STEEL, IC OR EMT (THIN WALL)ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS EXCEPT AS OTHERWISE APPROVED BY TENANT'S PROJECT MANAGER. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4 ", EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE THE SUSPENDED CEILING OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METALLIC TUBING MAY BE USED IN LIEU OF EMT FOR CONCEALED BRANCH CIRCUIT WIRING ONLY, WHERE PERMITTED BY LOCAL AUTHORITIES. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT, PERMITTED BY CODE. C. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600 VOLT INSULATION: 1. #10 AND SMALLER - SOLID, #8 AND LARGER - STRANDED. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLI CATIONS. 2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 3. GENERAL WIRING SHALL HAVE THHN INSULATION. 4. ALUMINUM CONDUCTORS, ROMEX OR BX ARE NOT PERMITTED. 5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCH -LOCK FOR #8 AND SMALLER, AND T & B LOCK -TITE FOR #6 AND LARGER. 6. WIRES SHALL BE COLOR CODED IN KEEPING WITH LANDLORD'S CONVENTION. D. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, 4" X 4 ", KNOCK -OUT TYPE WITH FIXTURE STUDS AS REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. E. WIRING DEVICES: 1. DEVICES AND COVERPLATES SHALL BE SPECIFICATION GRADE WITH A MINIMUM RATING OF 20 AMPS. COLOR OF DEVICES AND COVERPLATES IN SALES AREA GYP BOARD, TOILET ROOM AND STOCK ROOM TO BE WHITE. IN SALES AREA WAINSCOT AND MILLWORK THEY ARE TO BE IVORY. DEVICES AND COVERPLATES TO BE MANUFACTURED BY HUBBELL. EQUALS BY LEVITON OR COOPER WIRING DEVICES /EAGLE ELECTRIC. DUPLEX RECEPTACLE: HUBBELL #5262. QUADRAPLEX RECEPTACLE: (2) HUBBELL #5262 UNDER ONE (TWO GANG TYPE) COVERPLATE. ISOLATED GROUND RECEPTACLE: HUBBELL #IG -5262. QUADRAPLEX ISOLATED GROUND RECEPTACLE: (2) HUBBELL #I0 -5262 UNDER ONE (TWO GANG TYPE) COVERPLATE. WEATHERPROOF RECEPTACLE: HUBBELL #GF- 5262 -I WITH "WP26" ALUMINUM COVERPLATE. SPST SWITCH: HUBBELL #HBL -1221. THREE WAY SWITCH: HUBBELL #HBL -1223. F. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTIONS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND N.E.C. CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO A HEIGHT OF 6 FEET ABOVE FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL THREE WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO BUILDING STEEL. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. A SEPARATE ISOLATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS. G. ALL PANELBOARDS SHALL BE STANDARD DEAD -FRONT CONSTRUCTION WITH SIZE AND NUMBER OF SINGLE AND MULTI -POLE BOLT -ON BRANCH BREAKERS AS INDICATED ON THE PANEL SCHEDULE, AND WITH MAIN BREAKER AND MAIN LUGS AS INDICATED ON THE DRAWINGS. PANEL BUSSING SHALL BE COPPER. PANELBOARDS SHALL BE COMPLETE WITH TRIM, DOOR, CONCEALED HINGES, FLUSH LOCK, DIRECTORY FRAME AND NEATLY TYPED COMPLETED DIRECTORY CARDS. ALL PANELBOARDS SHALL HAVE DISTRIBUTED BUSSING AND SEQUENCE NUMBERING WITH NO TWO CONSECUTIVE CIRCUIT NUMBERS TIED TO THE SAME BUS OR PHASE. ALL PANELS AND BREAKERS ARE PRE - PURCHASED AND SHALL BE GE AS PART TENANT'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. ALL CIRCUIT BREAKERS USED FOR CONTROL OF LIGHTING CIRCUITS SHALL BE "SWD" RATED. H. DRY TYPE STEP -DOWN TRANSFORMER SHALL HAVE NEMA CLASS F INSULATION ON UNITS BELOW 30 KVA AND NEMA CLASS H INSULATION ON UNITS 30 KVA AND ABOVE. TRANSFORMER TO BE GENERAL PURPOSE VENTILATED TYPE WITH ALUMINUM WINDINGS. TRANSFORMER IS PRE - PURCHASED AND SHALL BE GE AS PART TENANT'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. I. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, 600 VOLT RATED, QUICK- MAKE /QUICK- BREAK, WEATHERPROOF (WHERE APPLICABLE), FUSED /NON -FUSED AS SHOWN ON THE DRAWINGS. SWITCHES USED FOR SERVICE ENTRANCE SHAL' BE "SE" RATED. STARTERS SHALL BE MINIMUM NEMA SIZE 1. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES ARE PRE - PURCHASED AND SHALL BE GE AS PART TENANTS NATIONAL ACCOI ANT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. J. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRIC SERVICE AND MAKE CONNECTIONS TO THE HVAC EQUIPMENT, SIGNS AND GRILLE MOTORS (IF APPLICABLE) AS SHOWN ON THE DRAWINGS. K. THE ISOLATED CIRCUIT OUTLETS AT CASH WRAP AREAS SHALL BE CLEARLY AND COMPLETELY MARKED FOR UNMISTAKABLE IDENTIFICATION BY THE OWNER'S EMPLOYEES. L. TEMPORARY WIRING SHALL BE REMOVED WHEN WORK IS COMPLETED. M. NO CONDUIT SHALL BE RUN THROUGH HVAC DUCTS. N. FINALLY 1. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETED IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING ARE APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. EL1O o1 -_�...: R 1t OMPP IVC9 WITH NFPA70 -NEC AUG 2 0 2010 BUILDING DIVISION RECEIVED AUG 03 2010 PERMIT CENTER ELECTRICAL SPECIFICATIONS IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE CONTACT THE ELECTRICAL DESIGNER: ANTHONY CARCHEDI: 612 - 465 -7686 / anthony.carchedi @dunhameng.com DUNHAM Dunham Associates, Inc. 50 South Sixth Street 1 Suite 1100 Minneapolis, Minnesota 55402 -1540 PHONE 612.465.7550 FAX 612.465.7551 WEB dunhameng.com mechanical + electrical consulting engineering IVFiv„ MBA Architects, Inc. 3823 Creekside Lane Holmen, WI 54636 608 - 785 -2760 FAX:608- 785 -2750 http: / /www.mba- architects.com PROJECT NAME: FRANCESCA'S COLLECTIONS PROJECT ADDRESS: SOUTH CENTER MALL TUKWILA, WA CLIENT NAME: FRANCESCA'S COLLECTIONS fSC' t? L 1.. T ( N s PROJECT MANAGER: 1- 14-1,0 DATE a 5 a. CONTRACTOR I REVISION 1 COMMENTS 6/29/10 X X MALL REVIEW 7/7/10 X X FINAL REVIEW 7/14/10 X X X PERMIT Drawn Bv: AKE [Checked Bv; , THIS SHEET CONTAINS: ELECTRICAL SPECIFICATION 0411995 -012 E4