HomeMy WebLinkAboutPermit EL10-0720 - SHASTA BEVERAGESHASTA BEVERAGE 1227 ANDOVER PK E EL1O-0720 Parcel No.: Address: Tenant Name: CityIllf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 3523049072 1227 ANDOVER PK E TUKW SHASTA BEVERAGE ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -0720 09/17/2010 03/16/2011 Owner: Name: NATIONAL BEVERAGE CORP Address: 8100 SW 10TH ST STE 4000 , PLANTATION FL 33324 Contact Person: Name: JEFF LOZIER Phone: 253- 405 -0173 Address: 4826 B STREET NW STE 101 , AUBURN WA 98001 Contractor: Name: KIRBY ELECTRIC INC Address: 4826 B ST NW, STE 101 , AUBURN WA 98001 Contractor License No: KIRBYEI077BN Phone: 253 859 -2000 Expiration Date: 01/13/2011 DESCRIPTION OF WORK: WAREHOUSE ADDITION. ADDING FLUORESCENT HI -BAY FIXTURES ON INTERIOR AND WALL PACKS /FLOODS ON EXTERIOR. (3) DOCK LEVELERS AND (2) FREEZE PROTECTION UNIT HEATERS. UTILIZING THE EXISTING PANELS. Value of Electrical Work: NRES: $30,000.00 Fees Collected: RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $760.63 National Electrical Code Edition: 2008 Date: "f -7-- I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am aut • rized to sign and obtain this electrical permit. Signature: Date: Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0720 Printed: 09 -17 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3523049072 Address: Suite No: Tenant: 1227 ANDOVER PK E TUKW SHASTA BEVERAGE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0720 ISSUED 09/09/2010 09/17/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: j) }'" ' doc: Cond -Elec EL10 -0720 Printed: 09 -17 -2010 CITY OF TUKVIA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. ! ° t�C Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1227 Andover Parkway E Tenant Name: Shasta Beverage Property Owners Name: Same King Co Assessor's Tax No ,5.2k56 4f = 96 'c.) Suite Number: Floor: New Tenant: ❑ Yes J ..No Mailing Address: 1227 Andover Parkway E Tukwila City WA State 98118 Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Jeff Lozier Mailing Address: 4826 B Street NW Suite #101 E -Mail Address: Jeff @kirbyelectric.com Day Telephone: Aubum City Fax Number: (253) 405 -0173 WA 98001 state (253) 859 -2363 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Jeff Lozier 4826 B Street NW Suite #101 Contact Person: Jeff Lozier E -Mail Address: Jeff @kirbyelectric.com Contractor Registration Number: KIRBYEI077BN Aubum WA City State Day Telephone: (253) 405 -0173 Fax Number: (253) 859 -2363 Expiration Date: 01/13/2011 98001 Zip Valuation of Project (contractor's bid price): $ 30,000 Scope of Work (please provide detailed information): Warehouse addition. Adding fluorescent hi -bay fixtures on interior and wall packs /floods on exterior. (3) Dock levelers and (2) freeze protection unit heaters. Utilizing the existing panels. Will service be altered? ❑ Yes 0 No Adding more than 50 amps? ❑ Yes m No Type of Use: Type of work: ❑ New 0 Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: m Puget Sound Energy ❑ Seattle City Light H: Applicatrons\Fonns- Appltcanons On Line12010 Applications \7 -2010 - Electrical Permit Application.doc bb Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONJRACTOR: Signature: Print Name: F� Mailing Address: 4826 B Street NW Suite 101 IDate Application Accepted: Day Telephone: Auburn city Date: 08/25/2010 (253) 405 -0173 I/✓A State 98001 Zip 0 Date Application Expires: Staff Initials: H.\Applicauons\Forms- Applications On Line 2010 Applications \7 -2010 - Electrical Pemut Apphcauon.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3523049072 Address: 1227 ANDOVER PK E TUKW Suite No: Applicant: SHASTA BEVERAGE RECEIPT Permit Number: EL10 -0720 Status: PENDING Applied Date: 09/09/2010 Issue Date: Receipt No.: R10 -01781 Initials: User ID: Payee: TLS 1670 Payment Amount: $760.63 Payment Date: 09/09/2010 10:06 AM Balance: $0.00 KIRBY ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 511643 760.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 608.50 000.345.832.00.00 152.13 Total: $760.63 PAYMENT RECEIVED doc: Receiot -06 Printed: 09 -09 -2010 INSPECTION RECORD Retain a copy with permit IN ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 646 "Type of Inspection: Address: m? ? Date Called: Special Instructions: Date Wanted: //1 a.m: Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. OMMENTS: 0 6/ eA) ao.511 idsrpmA, Inspector: N REINSPECTION FEE REQUIRED. P for to next inspection. fee must be Date: a„�/ le/11 paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D -1970 PERMIT NO. (Z CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 6),Mr 1A 6tiezS Type of Inspection: Address: ' tA4 7 t •••., ( Date Called: Special Instructions: Date Wanted: /g/Z-Z) m` .m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior.to approval. l COMMENTS: p 6(20 Ji\b141,1 /11.5-04pieNkii i `TD 51 bC& Inspector: Date: /2/141/0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION l" (206) 431-367 biro -0720 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: at4 4yII pT E .r Ae1 Type of Inspection: 700 COMMENTS: Address: aL� Date Called: Special Instructions: Date Wanted: /2. IC gym. gyp. Requester: Phone No: (4oJ449 waJtaA> B KJApproved per applicable codes. Corrections required prior to approval. COMMENTS: d.K. , V/ 5i 649J, ir 'a)oQK 1.i)ai, orb :- Jig (4oJ449 waJtaA> B o g (5-macI-Jai, TD Inspector: Gicit6rriAl6f Date: /21/4 /!C) REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Proj Address SHASTA BEVERAGE Date 9/8/2010 Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) For Bulidin Dearttment Use li t , ��� b. i ''0 t+++ .� 4, 1p�,Q!}� W 4� �,G C ii 1227 ANDOVER PARKWAY_ E _____ ,__ TUKWILA, WA 98118 Name: KIRBY ELECTRIC (�� 1 � Appl. Name 4826 B ST NW, STE. 101, AUBURN, WA OVERHANG Appl. Phone 253 - 859 -2000 Project Description 606.3 ❑ Plans Included requirements. ❑ New 4 Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. installed wattage not increased. & space use not changed. �RE c N Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Other Entries WAREHOUSE DOORS 20 W /LF of door widt 63.0 1260.0 Canopies and Overhangs OVERHANG 1.25 W /ft2 485.0 606.3 Tradable Proposed Lighting Wattage Total Allowed Watts 1866.3 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed ADDITION FLOOD LIGHTS 8 150.0 1200.0 250.0 1750.0 -A70•NEC Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts 1200.0 Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Bldg. Fagade (by perim) NEW ADDITION 5.0 W /If 608.0 3040.0 250.0 1750.0 -A70•NEC Non - Tradable Proposed Lighting Wattage -- VIEWED.FOR Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed i% • • ' : EyW1 r WALL PACK 7 250.0 1750.0 -A70•NEC EI' 1 ZLUlU Pr City of Tukwila BUILDING DIVISION osed Watts may not exceed Allowed Watts for Category ELIO 0710 RECEIVED SEP 09 2010 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form exterior Lighting Summary (back) LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDINGEXTERIORS Revised July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft2 Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft2 Stairways 1.0 W /ft2 Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft2 Street frontage for vehicle sales lots in addition to "open area" allowance 20 W /linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the s specific application and senot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W /ft2 for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 2 1.25 W/ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Material handling and associated storage 0.5 W /ft2 Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry REVIEWED FOR COMPLIANCE WITH NFPA 70 -NEC SEP 14 2010 bity of Tukwila BUILDING DIVISION • 2006 Washington State Nonresidential Energy Code Compliance Form In erior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info -� _�_- - Project Address SHASTA BEVERAGE Date 9/8/2010 1227 ANDOVER PARKWAY E For Building lintpi rt®pli I li•-smIai# MA TUKWILA, WA 98118 Applicant Name: KIRBY ELECTRIC Applicant Address: 4826 B ST NW, STE. 101, AUBURN, WA 0.50 Applicant Phone: 253 - 859 -2000 Project Description ❑ Plans Included requirements. ❑ New Building -' Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area NORTH 6-LAMP T8 FBAY WAREHOUSE 0.50 42812.0 21406.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 21406.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed WAREHOUSE 6-LAMP T8 FBAY 85 169.0 14365.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 14365.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual � I�� Ed. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, curr nt limiting devices or of the transformer. wirpi -•r exempt lighting, note section and exception number, and leave Watts /Fixture blank. NFPA70 - NEC SEP 14 2010 Cky of Tukwila BUILDING DIVISION RECEIVED PERMIT CENTER E L10--0720 SEP 09 2010 2006 Washington State Nonresidential Energy Code Compliance Form I erior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces_-__ _ - Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector ) p ) or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools. hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations* 1.0 Cafeterias, fast food establishments*, restaurants /barns . 1.3 Post office 1.1 Dormitory 1.0 Retail", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces'' 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition ha113:' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries* 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all thre= o/ a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). �+���D�O� b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and ICOMPLIANCEsWITH of track attachment). NFPA 70 - NEC c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. A �O1O l 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a wareho se may ef o computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the verti . face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. City of Tukwila BUILDING DIVISION • • PEW � ` Vic, COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0720 PROJECT NAME: SHASTA BEVERAGE SITE ADDRESS: 1227 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # DATE: 09 -09 -10 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: S tAk. Building Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete D<1 Incomplete n DUE DATE: 09 -14 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route 14 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 10-12-10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople �ter Friendly Page • Electrical Contractor A business licensed by LBI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company KIRBY ELECTRIC INC UBI No. 2538592000 Status 4826 B St Nw Ste 101 License No. License Type Auburn Effective Date WA Expiration Date 98001 Suspend Date King Specialty 1 Corporation Specialty 2 601433048 Active KIRBYEI077BN Electrical Contractor 1/15/1993 1/13/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status KIRBYE'101QEELEC ELEC TRIC Electrical Contractor General Unused 11/5/1990 11/5/1994 Archived MASTER ELECTRICIAN INFORMATION License KIRBYDE962LZ Name KIRBY, DOUGLAS E Status Active Business Owner Information Name Role Effective Date Expiration Date KIRBY, DOUGLAS E Cancel Date 01/01/1980 Bond Amount KIRBY, SHANNON 5 01/01/1980 70607132 KIRBY, SHANON E Agent 12/22/1992 ELECTRICAL CITATION Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 WESTERN SURETY CO 70607132 01/14/2009 Until Cancelled 19.28.271 RCW ELECTRICAL CITATION $4,000.0011 /05/2008 4 MERCHANTS BONDING CO (MUTUAL) WA 12415 01/14/2005 Until Cancelled 01/14/2009 $4,000.0011 /04/2004 3 CUMBERLAND CAS B SURETY CO MB009000727 01/14/2000 Until Cancelled 01/14/2005 $4,000.00 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ENORW00271 1/27/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHIR00274 9/24/2007 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 09/17/2010 ;1 NP WP H1 -11 TYPE FB FB /EM FL WP EM LIGHTING SCHEDULE DESCRIOPTION (6) LAMP T8 F -BAY LIGHT FIXTURE (6) LAMP T8 F -BAY LIGHT FIXTURE W/ EM BALLAST 150W FLOOD LIGHT FIXTURE 275W WALL PACK LIGHT FIXTURE EXIT /EMERGENCY COMBO SEPARATE PERMIT REQUIRED FOR: Iii611echanical ❑ Electrical &Plumbing t as Piping City of Tukwila RP! _,T NG DIVISION 0 EM FL H1 -11 EM WHSE RECEPTACLE L1 -16 FL nU1 -11 FB FB FB FB 0 FB FB FB FB FB FB FB 0 0 0 0 FB FB FB FB FB FB FB FB FB FB FB I UH -11 I Ij L1 -18 FB FB i RELOCATED CAN CRUSHER H1- 38,40,42 50AMP 480V 0 NEW ADDITION POWER PLAN SCALE 1 "= 10' -0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Revisions will require a new plan submittal may include additional plan rTf!r I f7cs FILE COPY Permit No. L W 61 20 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the v olation of any adopted code or ordinance. Receipt o1 approved Field Copy and conditions is acknowledged° By D e: ...22./ n City Of Tukwila BUILDING DIVISION NO. H1 LOCATION: EXISTING BUILDING FED FROM: EXISTING MAIN SWITCH BOARD DH1 277/480V 225A BUS CKT N0. LOAD DESCRIPTION TRIP AMPS VA LOAD TRIP AMPS LOAD DESCRIPTION CKT N0. 1 E LTG OFFICE AREA 20 1600 A 5000 20 (E) DUCT HEATER DH -1 2 4 6 3 E LTG OFFICE AREA 20 2000 B 5 E LTG OFFICE AREA 20 1400 c 7 E FLOOD LIGHTING 20 2000 A 5000 20 (E) DUCT HEATER DH -2 8 10 12 9 E BUILDING LIGHTING 20 1200 B 11 N WALL PACKS /FLOODS 20 2950 C 13 N WAREHOUSE F —BAYS 20 2672 A 5000 20 (E) DUCT HEATER DH -3 14 16 18 15 N WAREHOUSE F —BAYS 20 2672 B 17 N WAREHOUSE F —BAYS 20 2672 c 19 N WAREHOUSE F —BAYS 20 2338 A 5000 20 (E) DUCT HEATER DH -4 20 22 24 21 N WAREHOUSE F —BAYS 20 2004 B 23 N) WAREHOUSE F —BAYS 20 1837 C 25 . E) RECEPT. P.T. & T. . A 8000 20 (E) DUCT HEATER DH -5 26 28 30 27 . . . B 29 . . . c 31 . . A 10000 40 (E) AC UNIT 32 34 36 33 . . . B 35 . . 800 c_ 37 39 41 (E) TRANSFORMER T -1 50 20910 A B c 8000 50 (E) RELOCATE CAN CRUSHER 38 40 42 92,255 REMARKS: (E) EXISTING LOAD (N) NEW LOAD CONNECTED LOAD: 92.2 KVA 111.1 AMPS DEMAND LOAD: 100.6 KVA 121.2 AMPS 0 L1 -14 H1 -19 H1 -17 132i1�'� L1 -14J L1 -14- H1 -15 EM NO. L1 LOCATION: EXISTING BUILDING FED FROM: EXISTING PANEL H1 120/208V 225A BUS CKT . LOAD DESCRIPTION TRIP VA LOAD is LOAD DESCRIPTION N0. 1 E RECEPT. WOM. LUNCH 20 900 A 500 20 E UH 2 &3 2 3 E RECEPT. OFFICE 20 900 B 500 20 E UH 8 &9 4 5 E RECEPT. GEN. OFFICE 20 720 C 250 20 E EXH. FAN 6 7 E RECEPT. GEN. OFFICE 20 720 A 3000 20 (E) WATER HEATER Q 8 10 9 E RECEPT. KITCHEN UNIT 20 180 B 11 E RECEPT. GEN. OFFICE 20 720 C 360 20 E) RECEPT. WAREHOUSE 12 13 E RECEPT. GEN. OFFICE 20 540 A 1200 20 N DOCK LEVELERS 14 15 E RECEPT. OFFICE 15 720 B 720 20 N WAREHOUSE RECEP 16 17 E RECEPT. WASHROOM 15 540 c 500 20 N UH 10&11 18 19 E) RECEPT. P.T. & T. 20 180 A . 20 23 (E) KITCHEN UNIT 20 5000 22 24 25 E LTG. WOM. LUNCH 20 loco A 26 27 E LTG. MENS ROOM 20 800 B 28 29 E PLANTER LIGHT 20 6D0 c 30 31 . . A . . 32 33 . . • 8 • . . 34 35 . . . c . . . 36 37 . . . A . . 38 39 . . 8 • . . 40 41 . . c . . 42 20,910 REMARKS: (E) EXISTING LOAD (N) NEW LOAD CONNECTED LOAD: 20.9 KVA 58 AMPS DEMAND LOAD: 25.6 KVA AMPS r- DH1 L- WHSE RECEPTACLES L1 -16 ) 400 30,000 I.C. RATING ON C.L. BREAKERS MINIMUM. 3.5 "C 3 #500,1 #4/0 ,3 "C 4 #4/0 MCC -2 H2 3�4 "C \/vv T2 45KVA 4 #2/0 )175 2.5" 4 #2/0 30KVA 2 "C 4 #1 /0 EFL ECTRICInc. COMMERCIAL-INDUSTRIAL www. kirbyelectric.com 4826 "B" St. NW Suite 102 Auburn, Washington 98001 (253) 859 -2000 (FAX) 859 -2363 SHASTA SHASTA BEVERAGE 1227 ANDOVER PKWY E TUKWILA, WA REVISIONS: 9 -8 -10 EXISTING ELECTRICAL RISER SCALE: N.T.S Ell() 20 RECEIVED SEP 0 9 2010 PERMIT CENTER SCALE: 1 /8 " =1 'o" DAT -6 -08 DRAWN BXb CHECKED BY: SHEET E1 JOB NO.: OF REVIEWED .FOR---- • PLIANCE WITH NFPA70 - NEC SEP 14 2010 • 'T' a B ILDING DIVISION EXISTING ELECTRICAL RISER SCALE: N.T.S Ell() 20 RECEIVED SEP 0 9 2010 PERMIT CENTER SCALE: 1 /8 " =1 'o" DAT -6 -08 DRAWN BXb CHECKED BY: SHEET E1 JOB NO.: OF