ELECTRICAL PERMIT
Permit Number: EL10 -0728
Issue Date: 09/17/2010
Permit Expires On: 03/16/2011
Owner:
Name: EVERGREEN ENTERTAINMENT COR
Address: 14060 INTERURBAN AVE S , TUKWILA WA 98168
Contact Person:
Name: DAVID RANKIN
Address: 9512 STONE AV N , SEATTLE WA 98103
Contractor:
Name: E H S LLC
Address: 9510 STONE AV N , SEATTLE WA 98103
Contractor License No: EHSLL * *033BC
Phone: 206 926 -9934
Phone: 206 527 -4422
Expiration Date: 01/03/2011
DESCRIPTION OF WORK:
INSTALL (2) PARKING LOT POLE LIGHTS IN PARKING AREA TO INCREASE SECURITY
Value of Electrical Work: NRES: $7,000.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected:
$266.13
National Electrical Code Edition: 2008
JL.
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfornce�of work�horized to sign and obtain this electrical permit. //
Signature: _ �\ Date: ����C G 7)
Print Name: % 1 1 7644
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -9/09
EL10 -0728 Printed: 09 -17 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 0002800004
Address:
Suite No:
Tenant:
14040 INTERURBAN AV S TUKW
RIVERSIDE CASINO
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
EL10 -0728
ISSUED
09/10/2010
09/17/2010
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Date:
917A
doc: Cond -Elec
ELI 0-0728 Printed: 09 -17 -2010
CITY OF TUK
Community Develtnt Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Electrical Pelt No. � � r 01
Project No.
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE, LOCATION
,� }King Co Assessor's Tax No.: 002-10 f &7" 1
Site Address: 14 40 1 /J7zs )( AiJ s Suite Number: Floor:
Tenant Name: rot rile, L KV �� (� New Tenant: ❑ Yes �'..No
Property Owners Name: %�1, Ind{ )IICJ �/'• /� / ,�
Mailing Address: L t/ t J` KK 41�
tty State
Zip
CONTACT PERSON — Who do we contact when your permit is ready to be issued
Name:
Day Telephone: MAO 1 zip i -! �y
Mailing Address: 5 is ..6Ta1lTS Aw N oC� �(%�4 1 Diza
City State Zip
E -Mail Address: J Ia (2 4L LC, 4 G� ry 1 Fax Number: b ,' Z7 4-41i
ELECTRICAL CONTRACTOR INFORMATION
Company Name: i G* 6L
Mailing Address: 'S IZ 67406 I$-Vrs k)
Contact Person: 1>W WkN ,4x Day Telephone: Z 1 41 '91 4
E -Mail Address: V\/ jZ '5 L. LG, �� Fax Number: ZPb 5Z7 44'z Z
Contractor Registration Number: git" j L(__ A-0 33 Expiration Date:
City State Zip
Valuation of Project (contractor's bid price): $ �%t�, r V `'
Scope of Work (please provide detailed information): I N �171'Uj(, fikgkiNG �r pax- 1 `�'�
GLf
!v 71/4- �'O t,i� 4z55/A-5 � �eGU�?.�'
Will service be altered? ❑ Yes JJ No Adding more than 50 amps? ❑ Yes �No
Type of Use: G�I4W1,(2(JkL ((t 7T iL'
Type of work:
❑ New ❑ Addition ❑ Service Changes Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
1
Puget Sound Energy
❑ Seattle City Light
H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Electrical Permit Application.doc
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $1 1.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
•
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured/mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
PERMIT APPLICATION NOTES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature: _ I_I
Print Name: 4t W PA4 /01
Mailing Address:4bla oQ is Atli
f
Date Application Accepted:
0111,01 t,0
Day Telephone:
6i A 7
City
Date Application Expires:
Date: q— IV t0
?oil efis+
103
State J Zip
Staff Initials:
H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Electrical Permit Application.doc
bh
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: hup://www.ci.tukwila.wa.us
Parcel No.: 0002800004
Address: 14040 INTERURBAN AV S TUKW
Suite No:
Applicant: RIVERSIDE CASINO
RECEIPT
Permit Number: EL10 -0728
Status: APPROVED
Applied Date: 09/10/2010
Issue Date:
Receipt No.: R10 -01850
Payment Amount: $212.93
Initials: WER Payment Date: 09/17/2010 09:55 AM
User ID: 1655 Balance: $0.00
Payee: EHS ELECTRICAL CONTRACTORS
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 81424 212.93
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
ELECTRICAL PLAN - NONRES
000.322.101.00.00 212.90
000.345.832.00.00 .03
Total: $212.93
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 09 -17 -2010
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0002800004 Permit Number: EL10 -0728
Address: 14040 INTERURBAN AV S TUKW Status: PENDING
Suite No: Applied Date: 09/10/2010
Applicant: RIVERSIDE CASINO Issue Date:
Receipt No.: R10 -01805
Initials:
User ID:
Payee:
JEM
1165
Payment Amount: $53.20
Payment Date: 09/10/2010 04:19 PM
Balance: $212.93
EHS ELECTRICAL CONTRACTORS, LLC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 81417 53.20
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.00 53.20
Total: $53.20
PAYMENT
RECEIVED
doc: Receiot -06 Printed: 09 -10 -2010
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
kleicS1 bf (396040
Type of Inspection:
2—/C310
Address:
p10110 WAS
Date Called:
Special Instructions:
Date Wanted:
1 / 3 0
,,,,,n
Cal
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval. 7
COMMENTS:
Inspector:
Date:
(11130/f0
n REINSPECTIOI1 FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD M
Retain a copy with permit 6,10 D 1�
/.)(1(
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project:
Type of Inspection:
Address:
NOW) (RJR.&
Date Called:
--
Special Instructions:
Date Wanted:
/oz.
�a.m/
p 111.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
OMMENTS:
/ vAivzwor\6. c34
r 15
Inspector:
6
Date:
(0 ( (�)
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
RIVERSIDE STORAGE BUILDING - (OLD RESIDENCE)
14040 Interurban Avenue South, Tukwila, WA 98168 -4723
LOAD CALCULATION
SQUARE FOOTAGE OF BUILDING
68' x 32' = 1792 SQFT
RESIDENTIAL SPACE
LIGHITNG 3 WATT /SQFT
KITCHEN CIRCUITS (2) @ 1'500 W EACH
LAUNDRY CIRCUIT
DEMAND ON RESIDENCE - FIRST 3000 AT 100%
REMAINING 6,876.00 @35%
RANGE CIRCUIT 8000 WATT RANGE
HEAT @ 10 W /SQFT
EXTERIOR LIGHTING
EXISTING 6 UNITS AT 150 WATT EACH
CONTINUOUS DEAMAND (125% OF CONNECTED)
NEW LIGHTING - (2) 250 WATT HPS @ 310 W EA
CONTINUOUS DEAMAND (125% OF CONNECTED)
@ 120/240 VOLT, 1PH, 3 WIRE
5,376 W
3,000 W
1,500 W City of.Tuttwlta
3,00 BUILDING DIVISION
2,407 W
�
EMVIEIIVEDmWfiH
NFPA70 -NEC
SEP 14 2010
8,000 W
17,920 W
900 W FILE COPY
225 Permit No.,
620 W
155 W
4 x !S T! 46 200 /- reoix !Z
ti$ i
00640,AlAitc4
1,900 W
33,227 WATT
138 AMP
CITY OF TUKINILA
SEP 10 2010
PERMIT CENTER
ctir 26D,4 Mk LUG
i= _ _ _- *.Q, C L(10 PANEL SCHEDULE ,11-04o
•_ - 0 . 6
NO.
OCATION:
1 _ -
�,
2
'
'.VOLTS _ ti O WIRE
SERVING: %-1
a
AMP
MAIN 1-06 S
4 '
._-__x
IT DES RIPTION
KVA
P
AMP
KVA
CIRCUIT ..DE RI IO
~ '
-
^ 4
'Cr477 r
3 ^
5^
7-
4
^ -6
^ -8!'P
=6
^ -'8
4076 FOPe
11-
9-
^10
—12
--14
^ 16
11
13-
13--
15 -^
17--
19--
21--
23--
25- -
15 ^^
.9
16
^ 18
• --,
^ 21
.,.y' T/1471 • a -
^ 20
21-
^22
^- 24
— 26
^
23-
.
4
, .
■
o•
^- 3a
-
-
2-7:
-
-.
27--
29--
^ -28
^ -30
`.,, SEP 14 201U
31 ^
33-
-32
^ 34
- •
--. -
mil
-
■
33--
____ (-T' in
^- 34--
--:-.-218---.
— 40
--
39-
37--
39--
41
�._
,...`.*-.-
we
-42
"°°-
e.
CONNECTED LOAD:
KVA AMPS
42
DEMAND LOAD:
KVA AMPS
�... - -" -.-..
CONNECTED LOAD:
KVA AMPS
DEMAND LOAD:
KVA AMPS
g 16 PANEL SCHEDULE '
NOLCATION:
'
;'
1 -- .
If
-- 2
12a VOLTS IRE
SERVING: ��VL & '
Zoe) AMP MAL S
CIRCUIT DESCRIPTION
KVA
MP
AMP
KVA
CIRCUIT DESCRIPTION
3 -1
5 ^2
7----
^ 4
^ -6
^ -8!'P
4076 FOPe
11-
.
�-12
14
13-
15 ^^
.9
16
• --,
^ 21
.,.y' T/1471 • a -
21-
^
23-
.
4
, .
■
o•
^- 3a
-
-
2-7:
-
-.
�-,
`.,, SEP 14 201U
31 ^
33-
-32
^ 34
- •
mil
35-
■
____ (-T' in
39-
Al-
we
-42
CONNECTED LOAD:
KVA AMPS
DEMAND LOAD:
KVA AMPS
RIVERSIDE CASINO
EHS Electrical Contractors
Available Fault Current Calculation
Utility Fault Current
I = kVA x 1000 = trans. FLA
E
Isca = trans. FLA x 100
transformer Z
Isca = ampere short- circuit current RMS symmetrical.
26,700
Point to Point Method
'f ' factor =
Multiplier
Length (distance)
2 x L x l (ASC)
N X C X E L -N # conductors per phase
Phase conductor constant
Volt Line to Line
amperes kVA =
E =
trans. FLA =
Isca =
FEET
V
Neutral conductor constant
Volt Line to Neutral
M= 1
1 + f Line to Line
Line to Neutral
Fault Current at Service Equipment
L =
Isca =
N
C
t L - L =
f =
C =
EL - N =
f =
75
208
361
361
1.8
20,032 amperes
80
26,700
Isca x M = fault current at terminals of main disconnect L- L =
Isca x M = fault current at terminals of main disconnect L- N =
9,110
2.254
7,474
by John Sokohk Ver. 6.3
jmpl idsCD.earthlink.net
Single Phase 208/120
Aluminum in Nonmetallic Raceway
Phase Conductor
Volt
Neutral Conductor
120 Volt
4.763
M = 0.307
M = 0.174
3/0
1/0
8,204 amperes
4,633 amperes
Fault Current from
FROM SERVICE EQUIP TO PANEL
Single Phase Feeder
'f' factor = 2 x L x 1
NxCxEL -N
Multiplier
M= 1
1 +f
Length (distance) L =
(ASC) Isca =
# conductors per phase N =
Phase conductor constant C =
Volt Line to Line E L - L =
f =
Neutral conductor constant C =
Volt Line to Neutral E L - N =
Line to Line
Line to Neutral
Isca x M = fault current at terminal of the panel L- L =
Isca x M = fault current at terminal of the panel L- N =
f =
M =
25
1Copper in Metal Raceway
8,204 Phase
1
12,844
Single Phase
4,633 Neutral
Phase Conductor
208 Volt
0.154
12,844
Neutral Conductor
120 Volt
0.150
0.867
0.869
3/0
3/0
COMPLIANCE COMPLIANCE WITH
NFPA 70 - NEC
7,1 7,11SEPI1113Ette€010
4,028 amperes
Calculation does not include motor contribution city orig a
2006 Washington State Nonresidential Energy Code Compliance Form
Project Summary
PRJ -SUM
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address
RIVERSIDE CASIO
Date 9/9/2010
14040 Interurban Avenue South
For Bu . r y L'.' :,..1.1 i 8_
(� � KWILA
SEP 10 2010
PERMIT CENTER
Tukwila, WA 98168 -4723
Applicant Name:
EHS ELECTRICAL CONTRACTORS
Applicant Address:
9512 STONE AVE N, SEATTLE, WA
98103
Applicant Phone:
206 - 5241 - +4422
FILE COPY
Permit No..
REVIEWED .FOR
COMPLIANCE WITH
NFPA 70 - NEC
SEP 14 2010
City of Tukwila
BUILDING DIVISION
uo o1Z%
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address RIVERSIDE CASIO
Date 9/10/2010
14040 Interurban Avenue South
For Building Department Use
Tukwila, WA 98168 -4723
Applicant Name: ERS ELECTRICAL CONTRACTORS
Applicant Address: 9512 STONE AVE N, SEATTLE, WA 98103
Applicant Phone:
206- 5241 - +4422
Project Description
❑ Plans Included
requirements.
❑ New Building ❑ Addition ✓ Alteration
Refer to WSEC Section 1513 for controls and commissioning
Compliance Option
0 Prescriptive 0 Lighting Power Allowance
(See Qualification Checklist (over). Indicate Prescriptive & LPA
0 Systems Analysis
spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
-, No changes are being made to the lighting
❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2*"
Area in ft2
Allowed x Area
storage
storage
0.50
1792.0
896.0
** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
896.0
Proposed Lighting Wattage
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture link ED FOR
COMPLIANCE WITH
NFPA70 -NEC
SEP 14 2010
City of Tukwila
BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary (back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
0 Warehouses, storage areas or aircraft storage hangers D Other
Q ualification Checklist
answer If is occupancy type is "Other" of and Pies in
answer is checked, the number of fixtures in
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
1521)
❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
) p )
or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
-1 Unit Lighting Power Allowance (LPA
Use'
LPA` (W /sf)
Use'
LPA` (W /sf)
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools hospitals, institutions, museums, banks,
churches) ,
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations"
1.0
Cafeterias, fast food establishments',
restaurants /bars'
1.3
Post office
1.1
Dormitory
1.0
Retaiiw, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia ", assembly spaces"
1.0
Theater, motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses ', storage areas
0.5
Hotel banquet/conference /exhibition hall34
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
laboratory" shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries'
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies3 (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
ootnotes for Table 15-
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
Reserved.
For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used.
Reserved.
For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W /ftZ.
Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all thr
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent an
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a ware
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the verti
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by rack
REVIE E,D .FOR
WITH
NFPA70 - NEC
use ma)Efaet7nei, fZ01O
al face area (access side only)
City of Tlukwja
BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
Exterior Lighting Summary
LTG -EXT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Proj Addres: RIVERSIDE cASIO
Date 9/9/2010
14040 Interurban Avenue South
For Building Department Use
Tukwila, WA 98168 -4723
Name: EHS ELECTRICAL CONTRACTORS
Appl. Name 9s12 STONE AVE N, SEATTLE, WA 98103
Appl. Phone
206-5241-+4422
Project Description
❑ Plans Included
requirements.
❑ New ❑ Addition ✓ Alteration
Refer to WSEC Section 1513 for controls and commissioning
Compliance Option
® Lighting Power Allowance
0 Systems Analysis
Building Grounds
(luminaires > 100 Watts)
motion Sensor
1 Efficacy > 60 lumens/VV ❑ Controlled by
❑ Exemption (list)
Alteration Exceptions
(check appropriate box sec. 1132.3)
❑ No changes are being made to the lighting
❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Tradable Maximum Allowed Lishtins Wattage
Tradable Locations
Description
Allowed Watts
per ft2 or per If
Area (ft2), perimeter
(10 or # of items
Allowed Watts
x ft2 (or x If)
Uncovered Parking and drives
parking lighting
0.15 W /ft2
25088.0
3763.2
NFPA70- EC
Tradable Proposed Lighting Wattage
Total Allowed Watts 3763.2
Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only,
the default table in the NREC Technical Reference Manual may also be used.
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
uncovered parking
high pressure sodium pole light
2
310.0
620.0
NFPA70- EC
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Non- Tradable Maximum Allowed Lighting Wattage
Total Proposed Watts
620.0
Non - Tradable Locations
Description
Allowed Watts
per ft2 or per If
Area (ft2), perimeter
(10 or # of items
Allowed Watts
x ft2 (or x If)
E, ose
COMPUANC WITH
NFPA70- EC
Non - Tradable Proposed Lighting Wattage
Location
Fixture Description
Number of
Fixtures
Watts/ Watts
E, ose
COMPUANC WITH
NFPA70- EC
Proposed Watts may not exceed Allowed Watts for Category
SEP 14 2010
City of•Tukwlla
BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
Exterior Lighting Summary (back)
LTG -EXT
2006 Washington State Nonresidential Energy Code Compliance Forms
TABLE 15 -2
LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS
Revised July 2007
Tradable Surfaces
(Lighting power
densities for uncovered
parking areas, building
grounds, building
entrances and exits,
canopies and overhangs
and outdoor sales areas
may be traded.)
Uncovered Parking Areas
Parking lots and drives
0.15 W /ft2
Building Grounds
Walkways less than 10 feet wide
1.0 W /linear foot
Walkways 10 feet wide or greater
Plaza areas
Special feature areas
0.2W /ft2
Stairways
1.0 W /ft2
Building Entrances and Exits
Main entries
30 W /linear foot of door width
Other doors
20 W /linear foot of door width
Canopies and Overhangs
Canopies (free standing and attached and
overhangs)
1.25 W /ft2
Outdoor Sales
Open areas (including vehicle sales lots)
0.5 W /ft2
Street frontage for vehicle sales lots in
addition to "open area" allowance
20 W /linear foot
Non - Tradable
Surfaces (Lighting
power density
calculations for the
following applications
can be used only for the
specific application and
cannot be traded
between surfaces or
with other exterior
lighting. The following
allowances are in
addition to any
allowance otherwise
permitted in the
"Tradable Surfaces"
section of this table.)
Building Facades
0.2 W /ft2 for each illuminated wall or
surface or 5.0W /linear foot for each
illuminated wall or surface length
Automated teller machines and night
depositories
270 W per location plus 90 W per
additional ATM per location
Entrances and gatehouse inspection
stations at guarded facilities
z
1.25 W/ft2 of uncovered area (covered
areas are included in the "Canopies
and Overhangs" section of "Tradable
Surfaces ")
Loading areas for law enforcement,
fire, ambulance and other emergency
service vehicles
0.5 W /ft2 of uncovered area (covered
areas are included in the "Canopies
and Overhangs" section of "Tradable
Surfaces ")
Material handling and associated
storage
0.5 W /ft2
Drive -up windows at fast food
restaurants
400W per drive - through
Parking near 24 -hour retail entrances
800 W per main entry
REVIEWED.FOR
COMPLIANCE WITH
NFPA70 - NEC
SEP 14 2010
Tukwila
BUILDING DIVISION
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK
2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address RIVERSIDE CASIO
Date 9/9/2010
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements
in the 2006 Washington State Nonresidential Ene gy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
n.a.
1513.2
Area controls
Maximum limit per switch
n.a.
1513.3
Daylight zone control
Schedule with type and features, indicate locations
n.a.
vertical glazing
Indicate vertical glazing on plans
n.a.
overhead glazing
Indicate overhead glazing on plans
n.a.
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
yes
(a) timer w /backup
Indicate location
n.a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
n.a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
n.a.
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
yes
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
n.a.
I 1514
IMax. watts
'Indicate watts for each exit sign
I
LIGHTING POWER ALLOWANCE (Section 1530 -1532)
n.a.
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
yes
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
n.a.
I 1511
IElec motor efficiency
IMECH -MOT or Equipment Schedule with hp, rpm, efficiency
I
TRANSFORMERS (Section 1540)
n.a.
I 1540
(Transformers
'Indicate size and efficiency
I
I
If "no" is circled for any question, provide explanation:
REVIEWED FOR
COMPLIANCE ECTH
NFPA70
SEP 14 2010
City of Tukwila
BUILDING DIVISION
2006 Washington State Nonresidential Energ Code Compliance Form
Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK
2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Lighting - General Requirements
1513 Lighting Controls: Lighting, including exempt lighting
in Section 1512, shall comply with this section. Where
occupancy sensors are cited, they shall have the features
listed in Section 1513.6.1. Where automatic time switches
are cited, they shall have the features listed in Section
1513.6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling- height partitions, shall be
provided with lighting controls located within that space. The
lighting controls, whether one or more, shall be capable of
turning off all lights within the space. The controls shall be
readily accessible, at the point of entry/exit, to personnel
occupying or using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces•which must be used as
a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that
may be controlled from a single switch or automatic control
shall not exceed that which is provided by a 20 ampere circuit
loaded to not more than 80 %. A master control may be
installed provided the individual switches retain their capability
to function independently. Circuit breakers may not be used
as the sole means of switching.
EXCEPTIONS: 1. Industrial or manufacturing process
areas, as may be required for production.
2. Areas less than 5% of the building footprint for
footprints over 100,000 ft2.
1513.3 Daylight Zone Control: All daylighted zones, as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device
provided that they do not include zones facing more than two
adjacent cardinal orientations (i.e. north, east, south, west).
Daylight zones under overhead glazing more than 15 feet
from the perimeter shall be controlled separately from daylight
zones adjacent to vertical glazing.
EXCEPTION: Daylight spaces enclosed by walls or
ceiling height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting.
1513.4 Display, Exhibition and Specialty Lighting
Controls: All display, exhibition or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Lighting for
all exterior applications shall have automatic controls capable
of tuming off exterior lighting when sufficient daylight is
available or when the lighting is not required during nighttime
hours. Lighting not designated for dusk -to -dawn operation
shall be controlled by either:
a. A combination of a photosensor and a time switch;
or
b. An astronomical time switch.
illuminated in a manner requiring manual operation of
the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
4. Hospitals and laboratory spaces.
5. Areas in which medical or dental tasks are
performed are exempt from the occupancy sensor
requirement.
1513.6.1 Occupancy Sensors: Occupancy sensors shall
be capable of automatically turning off all the lights in an
area, no more than 30 minutes after the area has been
vacated.
Light fixtures controlled by occupancy sensors shall have a
wall- mounted, manual switch capable of turning off lights
when the space is occupied.
EXCEPTION: Occupancy sensors in stairwells are
allowed to have two step lighting (high -light and low-
light) provided the control fails in the high -light position.
1513.6.2 Automatic Time Switches: Automatic time
switches shall have a minimum 7 day clock and be capable
of being set for 7 different day types per week and
incorporate an automatic holiday "shut -off' feature, which
turns off all loads for at least 24 hours and then resumes
normally scheduled operations. Automatic time switches
shall also have program back -up capabilities, which prevent
the loss of program and time settings for at least 10 hours, if
power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a. is readily accessible;
b. is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated;
c. is manually operated;
d. allows the lighting to remain on for no more than 2 hours
when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft2 or 5% of the
building footprint for footprints over 100,000 ft2, whichever is
greater.
1513.7 Commissioning Requirements: For lighting
controls which include daylight or occupant sensing
automatic controls, automatic shut -off controls, occupancy
sensors, or automatic time switches, the lighting controls
shall be tested to ensure that control devices, components,
equipment and systems are calibrated, adjusted and operate
in accordance with approved plans and specifications.
Sequences of operation shall be functionally tested to
ensure they operate in accordance with approved plans and
specifications. A complete report of test procedures and
results shall be prepared and filed with the owner. Drawing
notes shall require commissioning in accordance with this
paragraph.
1514 Exit Signs: Exit signs shall have an input power
demand of 5 Watts or less per sign.
Motors - General Requirements
1511 Electric Motors: All permanently wired polyphase
motors of 1 hp or more, which are not part of an HVAC
system, shall comply with Section 1437.
Lighting designated for dusk -to -dawn operation shall be EXCEPTIONS: 1. Motors that are an integral part of
controlled by an astronomical time switch or photosensor. All specialized process equipment.
time switches shall be capable of retaining programming and 2. Where the motor is integral to a listed piece of
the time setting during loss of power for a period of at least 10 •equipment for which no complying motor has been
hours.
EXCEPTION: Lighting for covered vehicle e
or exits from buildings or parking structures wh
required for safety, security, or eye adaptation.
1513.6 Automatic Shut -Off Controls, Interior: Bui
greater than 5,000 ft2 and all school classrooms sha
equipped with separate automatic controls to shut o
lighting during unoccupied hours. Within these buildi
office areas less than 300 ft2 enclosed by walls or c
height partitions, and all meeting and conference ro
all school classrooms, shall be equipped with occup
sensors that comply with Section 1513.6.1. For othe
automatic controls may be an occupancy sensor, ti
or other device capable of automatically shutting off
EXCEPTIONS: 1. Areas that must be contin
raa6RVpII�E��W��E+
COMPLIANC r . - General Requirements
dingsNFPA 6 1 40 TRANSFORMERS
be The minimum efficiency of a low voltage dry-type
the distri �•I n transf• mer shall be the Class I Efficiency Levels
gs, all sEP 1fq� In tra sformers specified in Table 4 -2 of the
ling- C#ui e or Determ ing Energy Efficiency for Distribution
s, and Transformers" pu • ished by the National Electrical
ncy Manufacturers As ociation (NEMA TP- 1- 2002).
swit � O kwlla
LDING DIVISION
illuminated (e.g., 24 -hour convenience stores), or
ItRafri COON COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL10 -0728 DATE: 09/10/10
PROJECT NAME: RIVERSIDE CASINO
SITE ADDRESS: 14040 INTERURBAN AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
X15 AWE.
Building ivision
Public Works
Fire Prevention
❑ Structural
Planning Division
Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete "trj
Comments:
Incomplete
DUE DATE: 09/14/10
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route IP Structural Review Required n No further Review Required ❑
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 10/12/10
Approved ❑ Approved with Conditions I Not Approved (attach comments) 111 Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pf ter Friendly Page
1
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
E H S LLC
2065274422
9512 Stone Ave N
Seattle
WA
98103
King
Limited Liability Company
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
601755865
Active
EHSLL" 033BC
Electrical Contractor
1/3/1997
1/3/2011
General
Unused
MASTER ELECTRICIAN INFORMATION
License WHETZR'964LS
Name WHETZEL, RICK
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
FRAWLEY, JOHN
Agent
01/01/1980
Bond Amount
WHETZEL, JEFFERY L
Partner /Member
01/01/1980
0405973
WHETZEL, RICK L
Partner /Member
01/01/1980
ELECTRICAL CITATION
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
INTERNATIONAL
FIDELITY INS CO
0405973
01/01/2006
Until Cancelled
19.28.101 RCW
ELECTRICAL CITATION
$4,000.00
12/27/2005
2
FIRST NATIONAL INS
COMPANY OF
6282027
01/01/2005
Until Cancelled
02/24/2006
ECOXE00311
$4,000.00
10/21 /2004
1
INS CO OF THE WEST
1492025
01/01/1997
Until Cancelled
01/01/2005
$4,000.00
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
ESTRL00714
12/2/2008
19.28.161 RCW
ELECTRICAL CITATION
Satisfied
$250.00
E46697
2/16/2005
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$1,000.00
EOLSR00269
5/4/2007
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
ECOXE00311
12/17/2008
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00