Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0772 - WESTFIELD SOUTHCENTER MALL - ARDEN B
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. El-1 0-0772 07 - 680 Southcenter Mall RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page Code Exemption = 8rlef E plainatoty Desclriptim Statuteftle The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit 16 Personal Information — expiration dates, or bank or other financial RCW DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. ARDEN B 680 SOUTHCENTER MALL EL10 -0772 City.f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 680 SOUTHCENTER MALL TUKW Tenant Name: ARDEN B ELECTRICAL PERMIT Permit Number: EL10 -0772 Issue Date: 10/13/2010 Permit Expires On: 04/11/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: MARGO KOZICH Address: 2136 PURCELL DR , FERNANDINA BEACH FL 32034 Contractor: Name: RED CEDAR ELECTRICAL CONSTRUCTION LLC Address: PO BOX 14294 , BOTHELL WA 98082 Contractor License No: REDCECE934C 1 Phone: 904 - 491 -6314 Phone: 425 - 315 -5075 Expiration Date: 02/21/2011 DESCRIPTION OF WORK: NEW AND RELOCATION OF EXISTING CEILING LIGHTING (PLEASE REFER POWER KEYED NOTES) ON PAGE E100 Value of Electrical Work: NRES: $15,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $438.13 National Electrical Code Edition: 2008 jfiJ U- --� Date: 0-1V l (1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perrff9% anncce off woork. I1 amm authorized to sign and obtain this electrical permit. Signature: Print Name: l ,�Cc B 141,) celai Date: 'O — / 3 —/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0772 Printed: 10 -13 -2010 • wq� City of Tukwila zDepartment of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: Address: Suite No: Tenant: 9202470010 680 SOUTHCENTER MALL TUKW ARDEN B • PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0772 ISSUED 09/29/2010 10/13/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: ACotr cAati& Date: /0 -/Y '10 doc: Cond -Elec ELI 0-0772 Printed: 10 -13 -2010 CITY OF TUKAPA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwila.wa.us • Electrical Permit No. E-L- 0— 0 7 7 2 Project No. - (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 60o oaJT/ (4'V76Z Tenant Name: &evti Property Owners Name: Mailing Address: King Co Assessor's Tax No.: 9Zo% ' , 7/0 Suite Number: ZZO Floor: 1 New Tenant: ❑ Yes ❑ ..No City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: 1l%/i /t:10 ‘oz/C P /ieb -t - %/%e/.,t-/ 4 Mailing Address: E -Mail Address: AeLio Day Telephone: lob' 4 /b 3/ /GV /V/4/41 /50-i 11- 3T03 t/ City SSttaatte Zip /r' Number: 94047- Y' 9/ ' 0 • ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): vL,¢ 6-/t./A /lam G/0 ,qr //ll(7 (fib let,e A '1•/6e / 14i 6 /oo ,oiv o/ 0/ 1/4 it-o ,/o7 oil/ Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ . Yes ❑ No Type of Use: Type of work: ❑ New 1;1 1. • Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:Wppltcations\Forms- Applications On Lane \2010 Applications \7 -2010 - Electrical Permit Apphcation.doc bh ■ Page 1 of 2 ❑ Remodel ❑ Telecommunication Tenant Improvement Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered 'circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, fiirnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued.within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated: • I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR FJF.CTRICAL CONTRACTOR: Signature: Print Name: / 1 /%/V rrnr/16Q / /06/t/ r) j�� Day Telephone: Mailing Address: / 41 f 1'� �i �/T 6 ff' / ,604./ 1.4Wo / Date Application Accepted: 1 Date: D� 91 State Zip Date Application Expires: 3 _��� ( 1 Staff Initials: H:Wpplications\Forns- Applications On Line \20I0 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0772 Address: 680 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/29/2010 Applicant: ARDEN B Issue Date: Receipt No.: R10 -02057 Payment Amount: $350.50 Initials: WER Payment Date: 10/13/2010 10:10 AM User ID: 1655 Balance: $0.00 Payee: JACOB CABUAG JR TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5099 350.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 350.50 Total: $350.50 doc: Receipt -06 Printed: 10 -13 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0772 Address: 680 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/29/2010 Applicant: ARDEN B Issue Date: Receipt No.: R10 -01935 Payment Amount: $87.63 Initials: WER Payment Date: 09/29/2010 12:03 PM User ID: 1655 Balance: $350.50 Payee: MIKE MONTGOMERY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 928 87.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 87.63 Total: $87.63 yk 72 doc: Receiot -06 Printed: 09 -29 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /2— 6,10-011 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: ji) Nd 6 Type of Inspection: i®'0 Address:p Date Called: Special Instructions: ` Date Wanted: am: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OM M ENTS: 00(04-(56 N1 Inspector: Date: it/Up c n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION RECORD Retain a copy with permit 6AO °OT ?2 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila. WA 98188 to (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 INSPECTION NO. Project: A Type of Inspection: POO Address: ��® i Date Called: '_ Special Instructions: Date Wanted: QQ a. Requester: 111111 Phone No: Approved per applicable codes. F�. Corrections required prior to approval. COMMENTS: NTS: > Cd Cf>feC5 t/ J r eL. Qco1 Orcr -rb e NrNJ b - 6F 4& S 1 } ,. 10 (1.`c (mfr tics 1)c t 14 ro& c (Add ° 6639A1 -ru, PJ 5. -re) tPubeik ANC-55 Af461,- )e)Jfi;(79‘)E.irS FQoJrD k r AC s I% WC s Inspector: /35fijoiq\ Date: 11/01,0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPEFTION NO. INSPECTION RECORD Retain a copy with permit ebw -0172- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 6 Type of Inspection: 700 1 Address: // (&o 11 Date Called: Special Instructions: ` Date Wanted: (a.rrl, Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: efik14-crios8, rift p sAIST M7 r ci-00(\ Cpv 6tc Inspector: ti &A/6\ Date: /170(//0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. /21-- INSPECTION RECORD Retain a copy with permit 6140 ° 0771 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Jt��N Type of Inspection: 70 3 Address: / 1 or Date Called: Special Instructions: Date Wanted: /D /2,5, a.m: Requester: Phone No: finApproved per applicable co El Corrections required prior to approval. COMMENTS: �t 6(Aki Cvi gad& tAl y./tOtere Inspector: d 1 Date: /���� 110 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. Euo -07'l CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 L/ij (206) 431 -3670 Project: Type of Inspection: ®D3 Address: 6wo Av� 7 Date Called: Special Instructions: Date Wanted: /° p.m. Requester: Phone No: EiApproved per applicable codes. El Corrections required prior to approval. COMMENTS: ro- "?006114 00 Inspector:, Date: 0/2 07/ F-7 REINSPECT! N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 640-o772. Project: Myr_ r°i 13 Type of Inspection: 00 Address: ao ti � Date Called: Special Instructions: Date Wanted: p 0 ar .. p.m. Requester: Phone No: Approved per applicable codes. plCorrections required prior to approval. COMMENTS: 1/56 G °' 0. -tt OV DaT5 a� 2-" ectilapr( ric Kt IJ) STEa- 6C2AIDJIr I Inspector: �I' `NI Date: 072—C)(1 v REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1)E d PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0772 DATE: 09 -29 -10 PROJECT NAME: ARDEN' B SITE ADDRESS: 680 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 0.1)41 ullding Division ir Public Works ❑ Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 09 -30 -10 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10 -28-10 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page 1 Electrical Contractor A business licensed by Lftl to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company RED CEDAR ELECTRICAL CONST LLC 4253571807 Po Box 14294 Mill Creek WA 98082 Snohomish Limited Liability Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602693686 Active REDCECE934C1 Electrical Contractor 2/21/2007 2/21/2011 General Unused Master Electrician INFORMATION License CABUAJK975P2 Name CABUAG, JACOB K M JR Status Active Business Owner Information Name Role Effective Date Expiration Date CABUAG, KANANI Partner /Member 02/21/2007 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 1 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 2/20/2007 Until Released Bond $4,000.002/21/2007 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip/Print.aspx 10/13/2010 A -15 I3 A -21 SYS. #1 SYS. #2 » 'vv.** . „ w: % :.w..:µ A -5 A -5 ROUTE TEIIW CONTACTOR SEE SHEET E400. LOCATE AS HIGH AS POSSIBLE ®A -29O n OUTE THRU CONTACTOR EE SHEET E400. A -5ze PARTIAL POWER PLAN SCALE: 1/4' - .a SEPARATE PERMIT L QUIRED FOR: l Mechanical Electrical Plumbing Gas Piping ty of Tukwila pylo DIVISION SOUND SYSTEM LEGEND SP CEILING SPEAKER. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. AUDIO EQUIPMENT LOCATION. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. E WALL MOUNTED VOLUME CONTROL. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. VC ALL SPEAKER CABLE TO BE WHITE 18 AWG, 2 CONDUCTOR, PLENUM RATED. ALL AUDIO SIGNAL WIRE TO BE 22 AWG, 2 CONDUCTOR W /SHIELD. SYS. #1 SYS. #2 PARTIAL POWER PLAN SCALE: 1/4' - r� REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: llevisions will require a new plan submittal and may include additional plan review fees. GENERAL ELECTRICAL NOTES 1. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL IMMEDIATELY NOTIFY THE OWNER'S PROJECT MANAGER OF ANY DISCREPANCIES. 2. ALL CONDUITS ARE TO BE CONCEALED IN WALLS OR ABOVE CEILINGS. CONDUITS IN EXPOSED CEILING AREAS SHALL EXIT WALLS AS CLOSE TO ROOF /FLOOR STRUCTURAL DECK AS POSSIBLE. 3. ANY EXISTING MATERIALS OR EQUIPMENT NOT TO BE REUSED MUST BE COMPLETELY REMOVED AND DISPOSED OF PROPERLY THROUGH THE LANDLORD'S DESIGNATED AND APPROVED HAULER. NO EQUIPMENT OR COMPONENTS MAY BE ABANDONED WITHOUT WRITTEN PERMISSION OF THE LANDLORD. 4. ANY PENETRATIONS THROUGH FIRE RATED WALLS NEED TO BE APPROPRIATELY FIRE STOPPED TO RETAIN THE WALL'S RATING. 5. CONTRACTOR SHALL ENSURE LOADS BETWEEN PHASES ON PANEL BOARDS ARE BALANCED WITHIN 10 %. 6. ALL LOW VOLTAGE WIRING IN CEILING PLENUM (INCLUDING TELEPHONE. DATA, ALARM AND TEMP. CONTROL WIRING) SHALL BE UL LISTED TEFLON PLENUM CABLE. GENERAL SPEAKER NOTES 1. G.0 /E.0 RESPONSIBLE FOR PROVIDING AND INSTALLING ELECTRICAL OUTLETS AND CONDUIT. 2. REFER TO EQUIPMENT OWNER'S AND INSTALLATION FOR ADDITIONAL DETAILS. 3. ALL HANGING HARDWARE TO BE WHITE AND INCONSPICUOUS. 4. ALL EXPOSED CABLE AND /OR CONNECTORS TO BE WHITE AND INCONSPICUOUS. USE ALL MEANS NECESSARY TO ENSURE NO CABLES ARE VISIBLE. GENERAL NOTES 1. MOUNT ELECTRICAL PANELS ON PLYWOOD BACKER BOARD(S). 2. THE T.E.C. IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE AND IS RESPONSIBLE FOR MAKING ALL MODIFICATIONS REQUIRED TO INSURE THAT THE TOTAL LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. ANY UPGRADES ARE AT G.G. EXPENSE. - CABLE TYPES AC AND NMC ARE NOT ACCEPTABLE. -ALL WIRE SHALL BE COPPER. - GROUND SEPARATELY DERIVE SERVICE. INCLUDE BUILDING STEEL IN GROUND IF POSSIBLE. - CIRCUIT BREAKERS SHALL BE BOLT -TYPE. -ANY FLEXIBLE CONDUIT SHALL NOT EXCEED 5' -0" IN LENGTH. - NEW ELECTRICAL WIRING MUST BE KEPT AS "INTERIOR" WIRING AND MUST BE COORRDINATED WITH MALL MANAGEMENT. - ALL ILLUMINATED SIGNS MUST BE CONTROLLED BY A 7 -DAY TIME CLOCK. 3. APPROVAL OF TENANT'S CONSTRUCTION DOCUMENTS AND SPECIFICATIONS BY THE LANDLORD DOES NOT RELEASE THE TENANT OR THE TENANTS CONTRACTOR FROM COMPLYING WITH THE LEASE AGREEMENT AND ALL APPLICABLE BUILDING CODES AND GOVERNING REGULATIONS. 4. NOTHING IS PERMITTED TO BE ATTACHED TO, OR SUSPENDED FROM, OR PENETRATE THE ROOF DECK ABOVE. G.C. SHALL BE REQUIRED TO FRAME, BRACE AND /OR SUSPEND, AS NEEDED. TO /FROM THE TOP CHORD OF JOISTS OR STRUCTURAL STEEL WHICH EXIST ABOVE YOUR RESPECTIVE, TENANT SPACE. 5. COORDINATE ALL FLOOR CUTS WITH ON SITE FACILITY MANAGER. IT IS THE G.C. RESPONSIBILITY TO TAKE ANY PRECAUTIONS NECESSARY TO INSURE THAT ANY UNDERGROUND UTILITIES, ETC. ARE NOT DAMAGED DURING FLOOR CUT OUT. ANY DAMAGE SHALL BE REPAIRED AT G,C. EXPENSE. 6. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL ELECTRICAL CONDITIONS. 7. NO UTILITIES IN THE DEMISING PARTITIONS. 8. COORDINATE ALL FLOOR CUTS WITH ON SITE PERSONNEL. 9. STOREFRONT RECEPTACLE SHALL BE BLACK WITH BLACK FACEPLATES. REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 1 1 2010 City of tticwila BUILDING DIVISION A-5 I@ COPY Permit No. VIA017 . Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fief Copy �and conditions is acknowledged: By Datef! /d -/3^ /( City Of Tukwila BUILDING DIVISION POWER KEYED NOTES O1 PROVIDE ROUGH -IN ABOVE CEILING AND FINAL CONNECTION TO ILLUMINATED SIGN. PROVIDE DISCONNECT SWITCH AS REQUIRED. BY N.E.C. 600. O2 THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL, AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. PROVIDE A SQUARE 'D' #SDSA1175 SURGE ARRESTER FOR P.O.S. CIRCUIT. ® PROVIDE (7) CONDUITS, (1) DEDICATED P.O.S CIRCUIT, (1) FOR P.O.S. WIRING TO STOCKROOM PC, (1) EMPTY W /PULLSTRING TO WIRELESS ROUTER FOR INTERNET, (1) FOR GENERAL POWER CIRCUIT, (1) CAT 5 CABLE FOR INTERNET AND FOR PHONE LINES, (1) FOR PEOPLE COUNTER, AND (1) FOR FUTURE USE. ROUTE CONDUITS AS SHOWN ON PLAN DOWN WALL OR COLUMN AND BY CORE DRILLING FLOOR. PATCH FLOOR AS REQUIRED. E.C. SHALL FIELD VERIFY EXACT CONFIGURATION AND LOCATIONS WITH G.C. ® E.C. SHALL PROVIDE AND INSTALL P.O.S. RECEPTACLE HUBBELL 4 -PLEX #IG420 AND GENERAL USE DUPLEX RECEPTACLE FOR MISC. POWER. J- BOXES FOR RECEPTACLES SHALL BE SURFACE MOUNTED ON INSIDE OF THE CASHWRAP AT 18" A.F.F. O5 E.C. SHALL PROVIDE AND INSTALL QUAD PLEX RECEPTACLE AND TELEPHONE OUTLET MOUNTED AT 18" A.F.F. FIELD VERIFY EXACT CONFIGURATIONS AND LOCATIONS WITH FIXTURE INSTALLER AND G.C. ® E.C. SHALL PROVIDE AND INSTALL QUAD RECEPTACLE MOUNTED AT 18" A.F.F. AT BACKWRAP. 07 J -BOX FOR SIGN MOUNTED IN WALL DISPLAY AT 5' -0" A.F.F. FIELD VEIRY DATA AND POWER LOCATIONS. ® E.C. SHALL PROVIDE AND INSTALL A J -BOX WITH 5 PHONE OUTLETS AND A SEPARATE J- BOX WITH A SINGLE PHONE OUTLET. BOTH ARE TO BE MOUNTED 18" A.F.F. AT FIRST P.O.S. CABINET. O9 1" C. TO T.T.B. W/ CAT 5 CABLE FOR INTERNET. E.C. SHALL LEAVE 3' EXCESS CABLE AT T.T.B. & CASH WRAP. 10 E.C. SHALL PROVIDE AND INSTALL (2)3/4" CONDUITS. ONE WITH CABLE FROM FIRST P.O.S. CABINET TO PC FIXTURE IN THE STOCK ROOM. THE OTHER SHALL BE INSTALLED EMPTY WITH A PULLSTRING TO J -BOX LOCATED ABOVE FITTING ROOM DOOR. REFER TO DETAIL ON SHEET E300. 11 JUNCTION BOX WITH PULLSTRING AND 3/4" CONDUIT FOR PEOPLE COUNTER ABOVE FRONT DOOR. MOUNT ON INSIDE OF STOREFRONT SOFFIT AS HIGH AS POSSIBLE. CONDUIT SHALL TERMINATE AT REGISTERS. SEE DETAILS 2 AND 3 ON SHEET E300 FOR MORE INFORMATION. 12 E.C. SHALL PROVIDE (2) COMPLETE DOOR BELL SYSTEMS AS FOLLOWS: SYSTEM 1:24V. PUSHBUTTON, EDWARDS #1786, MTD. AT 48" A.F.F. AT REAR EXIT DOOR, CONNECTED TO 24V. TRANSFORMER EDWARDS #592, MOUNTED 10' -0" A.F.F. IN STOCKROOM AS SHOWN. TRANSFORMER TO BE CONNECTED TO (2) BELL UNITS. EDWARDS #13 -1G1 FIRST BELL UNIT TO BE LOCATED IMMEDIATELY ADJACENT TO TRANSFORMER IN STOCKROOM; SECOND BELL UNIT ABOVE SUSPENDED SOFFIT (12' -6 ") AT CASHWRAP. SYSTEM 2:24V. PUSHBUTTON; EDWARDS #1786, MOUNTED IN FRONT CASH WRAP, CONNECTED TO 24V. TRANSFORMER, EDWARDS #592 MOUNTED 10'- 0 "A.F.F. IN STOCKROOM AS SHOWN. TRANSFORMER TO BE CONNECTED TO (1) BUZZER UNIT, EDWARDS #15 -1G1, MOUNTED IMMEDIATELY ADJACENT TO TRANSFORMER. NOTE: SOUND OF BELL UNITS FOR SYSTEM 1 ARE TO BE DISTINCT FROM SOUND OF BELL. UNIT FOR SYSTEM 2. 13 E.C. SHALL PROVIDE AND INSTALL QUAD RECEPTACLE MOUNTED AT 18" A.F.F. FOR AMPLIFIER AND DVD SYSTEM. FIELD VERIFY EXACT LOCATION WITH G.C. 14 SPEAKERS AND RECEIVER PROVIDED AND INSTALLED BY OTHERS. E.C. SHALL SUPPLY AND INSTALL J -BOX AND 3/4" CONDUIT WITH PULLSTRING AT RECEIVER LOCATION. ONE CONDUIT SHALL RUN INSIDE WALL UP TO STRUCTURE AND STUB OUT. PLENUM RATED SPEAKER CABLE SHALL BE PULLED TO EACH SPEAKER LOCATION BY OTHERS. CABLING SHALL BE RUN TIGHT TO STRUCTURE AND PARALLEL AND PERPENDICULAR TO STRUCTURE. 15 20A RATED QUAD DEDICATED RECEPTACLE WITH ISOLATED GROUND ABOVE CEILING FOR SENSORMATIC SYSTEM. THE AC SOURCE MUST BE A 3 -WIRE 24 HOUR UNSWITCHED OUTLET WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. PROVIDE "LOCK -ON" DEVICE ON BREAKER AT PANEL. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH G.C. AND SENSORMATIC. THIS IS NOT A TOWER SYSTEM. DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210 -62. DUPLEX RECEPTACLE FLUSH MOUNTED AT 15" A.F.F. DUPLEX RECEPTACLE, PHONE AND FAX OUTLETS TO BE MOUNTED AT 38" A.F.F. FIELD VERIFY EXACT LOCATIONS. 19 E.C. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE /FIRE ALARM SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.C. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIO/VISUAL ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR A NEW SYSTEM AS MAY BE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL. INSTALL SMOKE DETECTORS IN SUPPLY OR RETURN DUCTWORK AS REQUIRED BY LOCAL AUTHORITY. FIELD VERIFY AND COORDINATE. @ QUADPLEX RECEPTACLE FLUSH MOUNTED AT 15" A.F.F. 21 PROVIDE JUNCTION BOX FOR LIGHTED WALL POWER. WALL PANELS WILL BE DELIVERED TO STORE WITH RECEPTACLES AND LIGHTING PREINSTALLED. CONTRACTOR TO PLUG IN LIGHTING TO RECEPTACLES, DAISY CHAIN NICHES TOGETHER, AND HARD WIRE CHAIN OF NICHE BOXES TO CIRCUIT PROVIDED. © NEW WATER HEATER SET ON PLATFORM ABOVE MOP SINK. SEE PLUMBING DRAWING P100 FOR MORE INFORMATION. • PROVIDE ROUGH -IN AND FINAL CONNECTION TO NEW AIR HANDLING UNIT ABOVE CEILING. CONTRACTOR SHALL PROVIDE ROUGH -IN AND FINAL CONNECTION TO CODE REQUIRED SERVICE OUTLET AND PULL CHAIN LIGHT AT UNIT. PROVIDE ROUGH -IN AND FINAL CONNECTION TO NEW HEAT PUMP ON ROOF. CONTRACTOR SHALL PROVIDE ROUGH -IN AND FINAL CONNECTION TO CODE REQUIRED WEATHERPROOF SERVICE OUTLET. SEE SHEET M100 FOR DETAILED INFORMATION. • FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB -IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. SEE ONELINE DIAGRAM ON SHEET E400. INSTALL NEW GFCI DUPLEX RECEPTACLE AT 42" A.F.F. RECEIVED SEP 29 2010 PERMIT CENTER ELIO -a77z M J2 ammo u r N A -2 QEM X -Ge j5 A( j5 A( PARTIAL LIGHTING PLAN SCALE: 44' - iV PARTIAL LIGHTING PLAN ELtO A /) 1) — REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC UCI 1 1 2010 O772 RECEIVED SEP 29 2010 PERMIT CENTER LIGHTING KEYED NOTES SPRINGWOUND OVERRIDE TIMERS FOR LIGHTING CONTACTOR. SEE CONTACTOR DETAIL FOR WIRING INFORMATION. MODEL SHALL BE INTERMATIC FF2H 2 HOUR OVERRIDE TO TURN LIGHTING ON WHEN TIMER IS OFF. EACH SWITCH SHALL BE MACHINE LABLED WITH DESCRIPTION OF LIGHTING CONTACTOR CONTROLLED. TOTAL OF 4 TIMERS IN THIS LOCATION. O EXIT AND EMERGENCY LIGHTING TO BE CONNECTED TO UNSWITCHED LEG OF LOCAL AREA GENERAL LIGHTING CIRCUIT LIGHT FIXTURE SCHEDULE QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NROEF VOLTS REC SUR PEN WAL 24 0 0 A B B1 F1 PRESCOLITE JUNO JUNO JUNO JUNO J1 DK LIVING J2 J3 CORBETT CORBETT J4 i CORBETT J5 Q CORBETT MERCURY LF6CFV32EB/ 6CFVWT .MX8- 70E- 8800XC X8- 150E- 8800XC TM256WH T620WH DK390061 6" COMPACT FLOURESCENT VERTICAL DOWNLIGHT W /REFLECTOR METAL HALIDE DOWN LIGHT W /REFLECTOR METAL HALIDE DOWN LIGHT W /REFLECTOR METAL HALIDE RECTANGULAR FLOOD /WALL WASH TRACK HEAD METAL HALIDE TRACK HEAD W /NARROW FLOOD OPTICS 13 X 18 CHANDELIER W/ MIRROR SHADE 109 -41 109 -47 109 -11 102 -12 MM- 132 —OCT- C— ELBUNI QEM MERCURY MM- 132 —OCT— C— ELBUNI —EM 10 sP 0 R i LIGHTOLIER LIGHTOLIER REM T2 JUNO T4 . JUNO 24 1 T6 JUNO 26 T8 f JUNO TE ! JUNO TC JUNO ® , X —G HIGHLITES SL4LB254U SL4LB254U —EM T2WH T4WH T6WH T8WH T38WH T23WH BPPLED5R EM LIGHT ALARMS 2MC12G2 —ELF3— M20 —M EM2 SURELITE RG -1 31 X 20 CHANDELIER CHAMPAGNE LEAF FINISH HAND CRAFTED IRON 12 X 7 CHANDELIER CHAMPAGNE LEAF FINISH HAND CRAFTED IRON 14 X 9 CHANDELIER CHAMPAGNE LEAF FINISH HAND CRAFTED IRON 18 X 13 SCONCE POLISHED NICKEL WITH LINEN SHADE 4' FLOURESCENT STRIP FIXTURE 1 1 120 1 X 120 1 120 1 120 1 1 120 120 4' FLOURESCENT STRIP FIXTURE W /EM. BATTERY BACKUP X 1,2,3 120 RECESSED 4' FLOURESCENT STRIP FIXTURE RECESSED 4' FLOURESCENT STRIP FIXTURE W /EM. BATTERY BACKUP SINGLE CIRCUIT 24" WHITE TRACK SINGLE CIRCUIT. 48" WHITE TRACK SINGLE CIRCUIT 72" WHITE TRACK SINGLE CIRCUIT 96" WHITE TRACK LIVE END POWER FEED WHITE 1 120 X 1 120 1 120 CENTER "MINI— CONNECTOR" FEED WHITE GREEN —WHITE LED EXIT SIGN W/ EMERGENCY BATTERY 1 120 1 I 120 1 120 X 2 —HEAD WHITE EMERGENCY LIGHT W/2 20W MR16 LAMPS RECESSED EMERGENCY WITH LEAD CALCIUM BATTERY Z # BROAN 680 COMBINATION LIGHT AND EXHAUST FAN FOR RESTROOM 1,3 120 1,3 1 120 X X X X X X X X X X LAMP SCHEDULE IXT / WAP/ FI FIXTURE MANUFACTURER/ LAMP ATTS AAOG O PHILIPS PLT42W/ 1 i 42 46 30/4P ALTO 1 ! 70 1 i 150 1 70 X 79 PHILIPS 23366 MHC70 /U /MP /3K PHILIPS 23366 169 MHC150 /U /MP /3K ALTO PHILIPS 22337 CDM70/T6 /830 34 PHILIPS CDMI25— PAR38 /FL 25 75 300 420 60 120 80 PHILIPS BC6OBA9C /CL /LL PHILIPS BC6OBA9C /CL /LL PHILIPS BC60B13 /CL /LL PHILIPS BC60B13 /CL /LL PHILIPS BC40BA9C /CL /LL 32 32 PHILIPS 24670 F32T8/TL835 ALTO PHILIPS 24670 F32T8/TL835 ALTO PHILIPS 60 F28T5 /830 /ALTO PHILIPS 60 F28T5 /830 /ALTO NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE 1 ( 5 5 INCLUDED L.E.D. 1 52 30 15 316 1. LAMPS AND FIXTURES SUPPLIED BY WET SEAL AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 2. LIGHT FIXTURES TO BE CHAIN HUNG AT 12' -0" A.F.F. IN STOCK ROOM WHEN NO CEILING IS PRESENT. SURFACE MOUNT IF CEILING PRESENT. 3. FIXTURES SHOWN WITH CROSS —HATCH ARE TO BE NIGHT LIGHTS. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. 4. GENERAL CONTRACTOR SHALL CLEAN AND RELAMP EXISTING FIXTURES TO REMAIN TO LIKE —NEW CONDITION. FIELD VERIFY LAMP TYPE. GENERAL CONTRACTOR TO CONTACT WETSEAL PROJECT MANAGER AT THE START OF CONSTRUCTION AND LET THEM KNOW OF THE QUANTITY OF LIGHTS FOR VENDOR IS TO PROVIDE LIGHTING. INCLUDED PHILIPS 22237 60A- 52A /EW 120V RELAMPING. PC TOWER, KEYBOARD, MOUSE, AND MONITOR PROVIDED AND INSTALLED BY OWNER VENDOR. E.C. SHALL PROVIDE AND INSTALL (2) 3/4" CONDUITS. ONE WITH CABLE FROM FIRST P.O.S. CABINET TO PC FIXTURE IN THE STOCK ROOM. THE OTHER SHALL BE INSTALLED EMPTY W /PULLSTRING TO J —BOX LOCATED ABOVE FITTING ROOM ENTRANCE AT 51" A.F.F. E.C. SHALL PROVIDE QUADPLEX RECEPTACLE FLUSH MOUNTED AT 15" A.F.F. 4 0 iM TONER w N 0 ao i z 0 ci m PC DETAIL SCALE: NONE T.G.0 TO PROVIDE AND INSTALL 34" TALL BY 24" WIDE BACKER BOARD FOR INSTALLATION OF TIME AND ATTENDANCE MACHINE. PAINT TO MATCH ADJACENT FINISHES. NOTE: INSTALLATION OF THREE PIECE BRACKET AND TIME AND ATTENDANCE MACHINE WILL BE PROVIDED BY OWNER AND INSTALLED BY VENDOR. PHONE BACKBOARD LINE OF CASH COUNTER BACK WALL SEE ARCHITECTURAL DRAWINGS FOR REFERENCES _p" 1'_p" II [0 Ii QUAD RECEPTACLES MOUNTED BELOW COUNTER 0 18" A.F.F. TELEPHONE RECEPTACLE MTD. BELOW COUNTER 0 18" A.F.F. REAR CASH /WRAP POWER SCALE: NONE NOTE: ALL LINES ARE CAT5 PLENUM RATED RUN TIGHT TO STRUCTURE ABOVE BY ELECTRICAL CONTRACTOR. WIRELESS INTERNET RELAY ABOVE FITTING ROOM DOOR. SEE PLAN FOR EXACT LOCATION. TIME CLOCK /PC LINE TERMINATE TIME AND ATTENDANCE P.C. AT EXISTING LOCATION OR AT LOCATION SPECIFIED ON PLANS. REG. 3 REG. 2 LINE FROM REG 1 TO REG 3 LINE FROM REG 1 TO REG 2 REG. 1 RUN TIGHT TO STRUCTURE ABOVE BY ELECTRICAL CONTRACTOR DSL LINE DSL BACKUP SPARE LINE \ DROP ALL CALBES DOWN WALL INSIDE CONDUIT. LINE DOORT SEE PLATE DIAGRAM 4/E300. SEE POWER SHEET E100 FOR TRENCH OR CORE DRILL REQUIREMENTS DSL WALL PLATE WITH NOISE FILTER I ELECTRICAL CASHWRAP DETAIL SCALE: NONE REGISTER 1 DATA JACKS MAIN VOICE & DSL BACKUP PHONE DATA RJ11 RJ11 T &A PC DELL PRINTER RJ45 RJ45 PEOPLE COUTNER WRAP RJ45 RJ45 DSL BACKUP BLUE JACK (X CONNECT TO SECONDARY #) PATCH TO US ROBOTICS MODEM. DSL 1 RED JACK (X CONNECT TO MAIN /DSL #) PATCH TO DSL MODEM. REG 2 YELLOW JACK. PATCH TO HUB PEOPLE COUNTER BOX ABOVE STORE FRONT DOOR. SEE PLAN FOR EXACT LOCATION. EL1�•o 772 REGISTER 2 DATA JACKS REG. 2 DELL PRINTER RJ45 RJ45 REGISTER 3 (4 & 5) BACKROOM AREA DATA JACKS DATA JACKS REG. 3 RJ45 UNDER COUNTER DETAIL PLATE DIAGRAM PINREG 3 GREY JACK. PATCH TO HUB. TIME CLOCK PC PEOPLE COUNTER ORANGE JACK BLUE JACK PRINTER WHITE JACK BACK /WRAP GREEN JACK CASHWRAP TPBcCA RJ45 MOUNT SURFACE JACKS ON SIDE PANELS TO INSURE THAT SCREWS DO NOT PROTRUDE OUT THE BACK OF THE CASHWRAP REG 2 YELLOW JACK PRINTER WHITE JACK REG 3 GREY JACK REG 1 REG 1 IS THE REGISTER CLOSEST TO THE STORE ENTRANCE BACK WALL ABOVE OR BELOW BACK COUNTER MAIN DSL/VOICE 1 BACK /WRAP FUTURE WITH DSL WALL DIGITAL SIGNAGE PLATE NOISE FILTER GREEN JACK. REG 2 REG 3 w 6 fr3....I`. 0 rn 0 N w o 2 RECEIVED SEP 29 2010 PERMIT CENTER UNDER COUNTER SCHEMATIC 3 OR MORE REGISTERS SCALE: NONE g 8 0 w a LLI { 0 0 —J E300 SYMBOL LEGEND . DESIGNATION EXIST. PNL 'A' (b 6 5I1 rl o PM 26 PI 4 ® = EXIST LOCATION X RELOCATED UNIPLEX RECEPTACLE (SINGLE) DUPLEX RECEPTACLE DUPLEX FLOOR MOUNTED DUPLEX ISOLATED GROUND DUPLEX FLOOR MTD ISO GRD DUPLEX SPECIAL LOCATION QUADPLEX RECEPTACLE QUADPLEX FLOOR MOUNTED QUADPLEX ISOLATED GROUND QUADPLEX FLOOR MTD ISO GRD QUADPLEX SPECIAL LOCATION SPECIAL VOLTAGE OR AMPERAGE SPECIAL VOLTAGE OR AMPERAGE MULTI - OUTLET PLUGMOLD TELEPHONE OUTLET JUNCTION BOX DATA OUTLET DOORBELL PUSHBUTTON DOORBELL DOORBELL LOW -VOLT TRANS LOW- VOLTAGE TRANSFORMER DISCONNECT SWITCH TELEPHONE BOARD ELECTRICAL PANEL TRANSFORMER 24HR 7 DAY -TIME CLOCK WALL SWITCH OCCUPANCY SENSOR 3 #12, 3/4 "C (2 CKT WIRES, 1 NEUTRAL, 1 GROUND) CIRCUIT HOME RUN CONDUIT THRU /BELOW FLOOR CONDUIT STUBBED UP /DOWN NIGHT LIGHT TIMECLOCK CONTROLED CIRCUIT • Q Q o a- iva ❑-� NEUTRAL - AMPERE BUS 200 AMPERE MAIN BREAKER KVA E ,T' - CKT. NO. T/c SERVICE $ I+ ---- -∎ - - - - a— N.L. VIA T/C CONTRACTOR'S NOTES A. ELECTRICAL CONTRACTOR SHALL VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE EXISTING CONDITIONS AND LIMITS OF CONSTRUCTION. B. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROTECT AND RETAIN POWER TO ALL EXISTING ACTIVE EQUIPMENT WHICH SHALL REMAIN. C. ALL REMOVED EQUIPMENT SHALL BE DISPOSED OF BY THIS CONTRACTOR UNLESS DIRECTED TO DO OTHERWISE. D. DISCONNECT, REMOVE, OR RELOCATE ALL EXISTING ELECTRICAL MATERIAL AND EQUIPMENT THAT INTERFERES WITH THE NEW INSTALLATION. THIS INCLUDES BUT IS NOT LIMITED TO PANELS, LIGHTING FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, BASEBOARD HEATERS, UNIT HEATERS, ETC. E. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC., WHICH MUST BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL OR ABANDONMENT BY THE MECHANICAL CONTRACTOR. F. REMOVE ALL CONDUIT, WIRE, BOXES, AND FASTENING DEVICES AS REQUIRED, TO AVOID ANY INTERFERENCE WITH THE NEW INSTALLATION. G. ELECTRICAL CONTRACTOR SHALL RECONNECT ANY EQUIPMENT BEING DISTURBED BY THIS RENOVATION, YET REQUIRED FOR CONTINUED SERVICE, TO THE SAME OR THE NEAREST AVAILABLE PANEL. H. WHERE WORK BY THE GENERAL CONTRACTOR (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC.) RESULTS IN THE REMOVAL, RELOCATION, OR REFEEDING OF ELECTRICAL DEVICES, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT OR RECONNECT, AS REQUIRED, ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM. I. CONTRACTOR SHALL RING OUT ALL CIRCUITS IN EXISTING PANELS EFFECTED BY THIS ALTERATION. WHERE ADDITIONAL CIRCUITS ARE NEEDED, RE -USE CIRCUITS AVAILABLE FOR RE -USE, OR PROVIDE NEW BREAKERS. TAG ALL UNUSED CIRCUITS AS SPARE AND REPLACE ALL INOPERATIVE OR DEFECTIVE CIRCUIT BREAKERS. TIGHTEN ALL CONNECTIONS. J. ELEC. CONTRACTOR IS TO FIELD VERIFY CONDITION OF EXISTING ELEC. EQUIPMENT AND RELOCATE AS REQUIRED. IF EXISTING EQUIPMENT IS NOT IN WORKING CONDITION CONTRACTOR SHALL PROVIDE NEW EQUIPMENT AS REQUIRED. SUB CONTRACTORS TO REVIEW DWG. T100 BEFORE BEGINNING WORK EACH CONTRACTOR SHALL WARRANTY HIS WORK FOR ONE (1) YEAR FROM THE OPENING DATE OF THE STORE ALL CONTRACTORS SHALL PERFORM THIER WORK ACCORDING TO STATE AND /OR LOCAL CODES. ALL OF THE ELECTRICAL WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. PANELBOARD 120208 DESIGNATION EXIST. PNL 'A' NEW INSTALL 225 EXIST LOCATION X RELOCATED EXIST _y VOLTS 3 PHASE 4 WIRE, SOLID NEUTRAL - AMPERE BUS 200 AMPERE MAIN BREAKER 1- F' X :ix. F' F - , D E ,T' - CKT. NO. BRKR. SIZE SERVICE LOAD (VA) PHASE LOAD (VA) SERVICE BRKR. SIZE CKT. NO. 1 20/1 REC -SHOW WINDOW 180 A 365 LTG - NIGHT/ EMERGENCY LIGHTS 20/1 2 3 20/1 REC- SENSORMATIC 360 B 1200 SIGN-STOREFRONT 20/1 4 5 20/1 REC - GENERAL 1080 C 550 LTG-SHOW WINDOW DOWN LIGHTS & TRACK 2011 6 7 20/1 REC- CASHWRAP 54Q A 600 LTG -SALES STRIP FIXTURES 20/1 8 9 2011 REC -POS 1080 B 770 LTG -SALES AREA DOWN LIGHTS 20/1 10 11 20/1 REC - BACKWRAP 720 C 1750 LTG -SALES AREA DOWN LIGHTS 20/1 12 13 20/1 SIGN - BACKWRAP 1200 A 1220 LTG- CASHWRAP 20/1 14 15 20/1 REC -PC /STOCK / TOILET ROOMS 900 B 1720 LTG-SALES ACCENT LIGHTING 20/1 16 17 20/1 REC - MICROWAVE 1200 C 685 LIGHTED WALL POWER 20/1 18 19 20/1 REC- FRIDGE 540 A 685 LIGHTED WALL POWER 20/1 20 21 20/1 REC -PHONE /DOORBELL 720 B 480 LTG - FITTING ROOM DOWN LIGHTS 20/1 22 23 2011 REC- MANAGERS DESK 360 C 1320 LTG- FITTING ROOM WALL SCONCES 20/1 24 25 20/1 REC -SOUND SYSTEM 360 A 475 LTG - TOILET /STOCK ROOMS /COORIDOR 20/1 26 27 20/1 TIMECLOCK / LIGHTING CONTACTOR 400 B 845 LTG-SALES AREA TRACK 20/1 28 29 20/1 REC - WIRELESS ROUTER 180 C 845 LTG-SALES AREA TRACK 20/1 30 31 20/1 SPARE A 845 LTG-SALES AREA TRACK 20/1 32 33 20/1 SPARE B 780 LTG-SALES AREA TRACK 20 /1 34 35 20/1 SPARE C 845 LTG-SALES AREA TRACK 20/1 36 37 100/3 EXISTING PANEL B 7705 A 845 LTG -SALES AREA TRACK 20/1 38 39 6515 B 840 LTG -SALES ACCENT LIGHTING 20/1 40 41 6455 C 840 LTG - STOREFRONT ACCENT LIGHTING 20/1 42 CONNECTED LOAD A: 15560 VA 49.000 KVA :TOTAL LOAD 136 AMPS B: 16610 VA 48.255 KVA :DEMAND LOAD 134 AMPS _ C: 16830 VA NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. BREAKERS AND CIRCUIT DESCRIPTIONS SHOWN IN LIGHT COLOR ARE EXISTING • - INDICATES THIS CIRCUIT TO RECEIVE HANDLE LOCK -ON CLIP PANELBOARD 120 /208_VOLTS DESIGNATION EXIST. PNL •B' NEW INSTALL ___ 100_AMPERE EXIST LOCATION X RELOCATED EXIST 3 PHASE 4 WIRE, SOLID NEUTRAL SURFACE BUS AMPERE MAIN LUG TOP FED X BOTTOM FED FLUSH MTD MTD X. _1OO __ CKT. NO. BRKR. SIZE SERVICE LOAD (VA) PHASE LOAD (VA) SERVICE BRKR. SIZE CKT. NO. 1 15/3 NEW AHU -1 940 A 5115 NEW HEAT PUMP HP -1 60/3 2 3 940 B 5115 4 5 940 C 5115 6 7 20/1 WATER HEATER 1650 A SPARE 20/1 8 9 20/1 AHU -1 RECEPT& LIGHT& HP -1 RECEPT 460 B SPARE 20/1 10 11 20/1 EXISTING FIRE ALARM 400 C SPARE 20/1 12 13 20/1 SPARE A SPARE 20/1 14 15 20/1 SPARE B SPARE 20/1 16 17 20/1 SPARE C SPARE 20/1 18 19 SPACE A SPACE 20 21 SPACE B SPACE 22 23 SPACE C SPACE 24 CONNECTED LOAD A: 7705 VA 20.675 KVA :TOTAL LOAD 57 AMPS B: 6515 VA 20.675 KVA :DEMAND LOAD 57 AMPS C: 6455 VA NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. BREAKERS AND CIRCUIT DESCRIPTIONS SHOWN IN LIGHT COLOR ARE EXISTING • - INDICATES THIS CIRCUIT TO RECEIVE HANDLE LOCK -ON CLIP EXISTING 100A FEEDERS TO REMAIN �- EXISTING PANEL B 120/208V SEE PANEL SCHEDULE EXISTING PANEL A 120/208V SEE PANEL SCHEDULE EXISTING 200A FEEDERS TO LL'S MAIN ELECTRICAL ROOM EXISTING 200A FEEDERS TO REMAIN TIMECLOCK L/C LIGHTING CONTACTOR ELECTRICAL ONE -LINE DIAGRAM SCALE: NONE A C NMPL CE WITH A 70 - NEC 011 1 1 2010 City o Tukwila • BUILDING DIVISIpN.. EXISTING 200A 120/208V 3PH 4 WIRE ELECTRICAL SERVICE TO SPACE TO BE REUSED INCLUDING 200A MAIN ELECTRICAL PANEL "A ", & 100A PANEL "B ". CONTRACTOR SHALL VERIFY CONDITION OF EXISTING EQUIPMENT AND REPAIR OR REPLACE AS NECESSARY. FLOOR UNE A -27 H • TORK TIMECLOCK MODEL #DTS400B T/C N • • • • 2 3 A -4 2 -HOUR OVER -RIDE SWITCHES INTERMATIC MODEL #FF2H. SEE SHEET E200 FOR LOCATION. (TYPICAL OF 4) SIGNAGE CONTACTOR #1 L/ A -13 ( A -6 w � A -6 hs_iTho A -1 m a 1 (9'c cc U . 1 I 1 2. • III 3• • III 4. SIGN - STOREFRONT 1 SIGN - BACKWRAP I SPARE I SPARE STOREFRONT CONTACTOR #2 L/ • A -10 L_ZA -12 Jr� w 0° aA -14 8.<1 ^ A -22 A -24 A -8 11 1 1• 2• 3. 4. 3. 4. LTG - SHWNDW DOWN v LTG - SHWNDW TRACK -{j a REC - SHOWWINDOW -Ij w cc 14 02 SPARE SPARE GENERAL LTG CONTACTOR #3 L/ C 1 • 11 CIRCUIT BREAKER AT PANEL A -28 SPARE 14 1 , 1• 2• 3. 4. 5. 6• DISPLAY LTG CONTACTOR #4 L/ 1 1 1 1 1 11 11 • 1 LTG -SALES GENERAL --Ij I LTG -SALES GENERALI -Sj I LTG -SALES STRIP Fs I LTG- CASHWRAP K LLTG- FITTING ROOM I-sj �I ! TG- FITTING ROOM I-rj TO UGHTING A -30 A -32 A -34 A -36 A -38 S- A -18 A -20 A -16 S-• • 2• 3. 4. 5. 6• 7. 8• 9. 10• LTG -TRACK LTG -TRACK LTG -TRACK LTG -TRACK LTG -TRACK LTG -TRACK REC - DISPLAY REC - DISPLAY LTG - ACCENT SPARE K K K K K K w O- wI W oz TIMECLOCK AND LIGHTING CONTACTOR CONTROL DIAGRAM SCALE: NONE 772. RECEIVED SEP 29 2010 PERMIT CENTER 1. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, THHW, OR NEC APPROVED EQUAL OR BETTER. ALL WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED ON NEC 110 -14c AND TABLE 310 -16. 2. E.C. SHALL FURNISH ANY NEW ELECTRICAL EQUIP. (PANELS, TRANSFORMER, CONDUITS, WIRE, METERS, SERVICE FEEDERS AND CONDUIT, DISC SWITCHES, CONTACTORS, TIMECLOCKS, ETC) AS REQUIRED TO PROVIDE A FULLY OPERATIONAL SYSTEM. 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING USED SHALL BE REMOVED FROM THE SITE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT PROJECT REP. 5. CONTRACTOR TO PROVIDE ANY ITEMS FROM ONE -LINE THAT ARE NOT EXISTING AS SHOWN. ITEMS SHALL INCLUDE: #8 CONDUCTORS FROM ROOF TAP BOX TO ROOFTOP UNIT, #8 CONDUTORS FROM ROOF TAP BOX TO 30 KVA TRANSFORMER, #3 CONDUCTORS FROM TRANSFORMERS TO PANEL LPA, TRANSFORMER GROUNDING PER NEC 250, AND 40 AMP FUSES IN BOTH 100 AMMP SWITCHES IN CABLE TAP BOX ASSEMBLY. DIVISION 16 - ELECTRICAL SPECIFICATIONS SECTION 16100 ELECTRICAL SPECIAL CONDITIONS 1. GENERAL A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ", AND DIVISION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY THIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTALLATION READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. 2. CONTRACTOR'S RESPONSIBILITY A. PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND /OR EXTEND ALL UTILITIES INCLUDING LIGHTING PANELS, POWER PANELS, ELECTRICAL SERVICE, PHONE SERVICE AND /OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HIS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ARE ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION, HE SHOULD CALL THIS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HELD RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS, ANY OF WHICH SHALL BE PRE - SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. WORKMANSHIP AND GUARANTEE A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS, AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURTHER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT EXPERIENCED WORKMEN EXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE GOOD AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINAL PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. CODES AND STANDARDS A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS, ORDINANCES, AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROLLING PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS, ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL. 5. FEES ON PERMITS A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. 6. CONTRACT DRAWINGS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERMIT. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES WHICH MAY BE REQUIRED, NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE MUTUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR EXISTING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LINES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SITE MAY NOT COINCIDE WITH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERIFY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY. C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODUCTS. EACH SHOP DRAWING SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS, QUANTITIES, CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS, AND SHALL BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLIANCE WAS CONFIRMED. B. APPROVAL OF SHOP DRAWINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER, WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL TERMS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF ALL EQUIPMENT PURCHASED, FOR PROPER FIT, AND OTHER DIMENSIONAL REQUIREMENTS. 8. RECORD DRAWINGS A. CONTRACTOR SHALL MAINTAIN AT THE JOB SITE ONE SET OF DOCUMENTS AS "RECORD DRAWINGS" FOR THE PURPOSE OF DAILY MARKING OF ALL SUBSTANTIAL REVISIONS TO THE DOCUMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL CHANGES, AND LOCATIONS OF UTILITIES, PANELBOARDS, DISCONNECTS, STARTERS AND OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT, OR SERVICE INCLUDING ACCESS THERETO, AT THE COMPLETION OF THE PROJECT, THIS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING FINAL "AS -BUILT DRAWINGS ". 9. EQUIPMENT SUBSTITUTION A. SPECIFIC MANUFACTURERS AND MODELS OF EQUIPMENT HAVE BEEN USED IN THE DEVELOPMENT OF THE DRAWINGS AND DESIGNS. THIS CONTRACTOR MUST SUBMIT TO THE OWNER ANY CHANGES AND /OR SUBSTITUTIONS FOR APPROVAL PRIOR TO INSTALLATION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNER'S APPROVAL MAY BE SUBJECT TO REMOVAL OR REPLACEMENT AS ORIGINALLY SPECIFIED, AND WILL BE AT THE CONTRACTOR'S EXPENSE. B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES ANY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING FROM SAID SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. EQUIPMENT INSTALLATION AND SUPPORT A. CONTRACTOR SHALL SUPPORT PLUMB, RIGID AND TRUE -TO -LINE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES, ETC., ARE TO BE SUPPORTED, MOUNTED, OR SUSPENDED AND SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE REQUIRED, CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL. B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. ALL CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED, TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. DEMOLITION A. ALL EXISTING EQUIPMENT, NOT INDICATED TO BE INCORPORATED INTO THE NEW SYSTEM SHALL BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL BY OTHERS FROM THE JOB SITE. CARE SHALL BE USED SO THAT NO DAMAGE IS DONE TO EXISTING BUILDING, PIPING, DUCTWORK, AND /OR ELECTRICAL EQUIPMENT. ANY DAMAGE ATTRIBUTED TO THIS CONTRACTOR SHALL BE REPAIRED OR REPLACED BY THIS CONTRACTOR. 12. CUTTING AND PATCHING A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SHALL BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES, COLORS, TEXTURES AND PROFILES. COLUMNS, BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. B. ALL WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. 13. CLEANING A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE IS DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES, MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 14. TESTS A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS AND SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE -TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS AND GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DEMONSTRATE CONFORMANCE TO THE SPECIFICATIONS. 15. TEMPORARY ELECTRICAL SERVICE (N /A) A. TEMPORARY ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. TEMPORARY LIGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONTRACTOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY LIGHTING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY -DUTY ELECTRICAL WELDING UNITS), ELECTRICAL HEATING UNITS, AND START -UP OF SPECIFIED BUILDING EQUIPMENT, WHICH IS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF ITS PERMANENT POWER CONNECTIONS. 16. EXCAVATION AND BACKFILL A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFILLED WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BACKFILLING. SECTION 16200 ELECTRICAL POWER AND LIGHTING 1. RELATED DOCUMENTS A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ", DIVISION 1 GENERAL CONDITIONS AND SECTION 16100 ELECTRICAL SPECIAL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAL SPECIAL CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. POWER SERVICE A. POWER SERVICE FOR THIS PROJECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE IN CONFORMANCE WITH THE LANDLORD'S REQUIREMENTS. 3. NAMEPLATES A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, PANELBOARDS, DISCONNECTS TRANSFORMERS, CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE PLY LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK. ENGRAVING SHALL EXTEND THROUGH THE FRONT LAMINATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREWS. B. CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HANDWRITTEN IS NOT ACCEPTABLE) AND SHALL IDENTIFY CIRCUIT AS TO TYPE AND LOCATION AS FOLLOWS: "LTG" - FOR LIGHTING CIRCUIT FOLLOWED BY AREA IN WHICH CIRCUIT APPEARS, I.E., "STOCKROOM ", "CASH WRAP ", ETC. "RECEPT" - FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA IN WHICH RECEPTACLE APPEARS, "STOREFRONT ", "CASH REGISTER ", ETC. "MOTOR" - FOR MOTOR FOLLOWED BY THE EQUIPMENT IDENTIFICATION AND AREA IN WHICH MOTOR IS LOCATED, I.E. "EXH FAN TOILET ", "AHU- ROOF ", ETC. 4. CONDUIT A. ALL WIRING SHALL BE RUN IN CONDUIT. THIN WALL EMT CONDUIT SHALL BE USED SIZES 1/2" THROUGH 2-1/2". ALL CONDUITS LARGER THAN 2-1/2" SHALL BE HEAVYWALL. CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE PVC JACKETED. FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED IN WET AREAS AND ON ALL MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS, AT A MAXIMUM LENGTH OF 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. SHALL BE ALLOWED. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL BE CLOSED WITH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS, TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. O.Z. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WITHIN THREE FEET OF EACH BEND, AT EVERY OUTLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 5. WIRE AND CABLE ALL CONDUCTORS SHALL BE COPPER A. ALL WIRE AND CABLE SHALL BE RUN IN CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE NEC AND SHALL MEET ALL ASTM SPECIFICATIONS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SIZE AND INSULATION TAGS. B. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SIZES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. 8 AWG SHALL BE "THHN." SIZE 4 AWG AND LARGER SHALL BE "THW." D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHALL BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL. 6. COLOR CODING A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOAD. - - 120/208V: PHASE A-- BLACK, PHASE B - -RED, PHASE C- -BLUE, NEUTRAL -- WHITE, GROUND - -GREEN - - 277/480V: PHASE A-- BROWN, PHASE B-- ORANGE, PHASE C-- YELLOW, NEUTRAL - -GRAY, GROUND - -GREEN 7. BOXES AND FITTINGS A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDIZED BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2" PARTITIONS SHALL BE AT LEAST 1 1 /2" DEEP AND /OR DEEPER IF REQUIRED BY THE DEVICE THEY HOLD OR THE NATIONAL ELECTRICAL CODE. B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SIZE AS REQUIRED BY THE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2" DEEP OR LESS THAN 4" SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH FOUR BOLTS. 8. CIRCUIT BREAKER PANELBOARDS (AS APPLIES) (N /A) A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED, WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACIIY IN EACH PANEL. B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10,000 AMPERES FOR 120 /208 AND 14,000 AMPERES AT 277/480. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTIVITY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED . IN UL STANDARD UL 67. D. CABINET SIZES ARE BASED UPON A 20" WIDE BY 6" DEEP PANEL UNLESS OTHERWISE NOTED. PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC COMPANY, OR WESTINGHOUSE. F. IF CIRCUIT BREAKERS ARE TO BE USED AS THE SWITCH CONTROL OF LIGHTING CIRCUITS, THE BREAKERS MUST BE APPROVED FOR THAT USE (TYPE "SWD "). 9. TOGGLE SWITCHES A. TOGGLE SWITCHES SHALL BE WHITE AND SHALL BE RATED 20 AMPERES 120/277 VOLT AC TYPE AS MANUFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: SINGLE POLE -- 1221 - -1 THREE WAY -- 1223 - -1 B. TOGGLE SWITCHES SHALL BE MOUNTED 4' -0" ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, INSTALLED ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION INDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. 13. GROUNDING A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN - UNION, BURNDY, OR 0 -Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL. WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS IN THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDED NEUTRAL BAR INSIDE THE MAIN PANEL. 14. LIGHTING FIXTURES A. ALL LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR SHALL INSTALL LIGHTING FIXri.IMES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, CO'APLETE WITH HANGERS, PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST, STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT FIXTURES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC "MAXI -MISER II" OR ADVANCED MARK III. WHERE OCTRON LAMPS ARE SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FINISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 15. TELEPHONE SERVICE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4" PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. 16. SURFACE METAL RACEWAY A. SURFACE METAL RACEWAY SHALL BE TWO PIECE #2100 AS MANUFACTURED BY WIREMOLD. ALL NECESSARY ACCESSORIES REQUIRED TO FIT THE CONFIGURATION SHOWN SHALL BE PROVIDED. RECEPTACLES SHALL BE 120 VAC, 23 APMS, CATALOG NUMBER #2127GT. 17. TRANSFORMERS A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. B. COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE D CORPORATION OR GENERAL ELECTRIC 18. TIMECLOCKS A. TIMECLOCKS SHALL BE 24 HOUR, 7 DAY DAY SKIPPER TYPE AS MANUFACTURED BY TORK, INTERMATIC, OR PARAGON. 19. CONTRACTORS A. TENANT SHALL EMPLY LANDLORD'S APPROVED CONTRACTOR TO INSTALL ROOM SMOKE DETECTORS, AUDIO/VISUAL ALARMS, AND RELAY TO SHUT DOWN RTU AS WELL AS ANY REQUIRED CONNECTIONS TO THE MALL MASTER ALARM SYSTEM. WIRING FROM RELAY TO RTU IS TO BE BY TENANT ELECTRICAL CONTRACTOR. REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC OCi 1 1 2010 City of Tukwila BUILDING DIVISION C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SLATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE. 10. RECEPTACLES A. RECEPTACLES SHALL BE WHITE AS MANUFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE - -20A -120 VOLT 5362 -1 B. RECEPTACLES SHALL BE MOUNTED 12" ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, SLATER, BRYANT AND LEVITON WILL BE ACCEPTABLE. 11. DEVICE PLATES A. DEVICE PLATES SHALL BE WHITE UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUBBLE INC., BRYANT AND LEVITON WILL BE ACCEPTABLE. 12. DISCONNECT SWITCHES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED, MANUFACTURED BY SQUARE D CORPORATION, ITE, GE, OR WESTINGHOUSE. END OF DIVISION 16 L%OO1 7 RECEIVED SEP 29 2010 PERMIT CENTER