Loading...
HomeMy WebLinkAboutPermit EL10-0787 - MIZUKI JAPANESE BUFFETMIZUHI JAPANESE BUFFET 17950 SOUTHCENTER PY EL1O-0787 Parcel No.: Address: Tenant Name: Cit' f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wwwci.tukwila.wa.us 3523049123 17950 SOUTHCENTER PY TUKW MIZUKI JAPANESE BUFFET ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -0787 10/18/2010 04/16/2011 Owner: Name: Address: Contact Person: Name: Address: MADISON INVESTMENTS LLC P O BOX 1922 , BOZEMAN MT 59771 JAKE YUN 18602 37 DR SE , BOTHELL WA 98012 Contractor: Name: UNIVERSAL ELECTRIC INC Address: 18602 37 DR SE , BOTHELL WA 98012 Contractor License No: UNIVEEI985D2 Phone: 206 - 354 -3932 Phone: 206 - 354 -3932 Expiration Date: 03/22/2012 DESCRIPTION OF WORK: USING 3 (EXISTING) 200 AMP 3 PHASE SERVICE PANELS, PROVIDE AND WIRE FOR ENTIRE RESTAURANT; LIGHTING, EQUIPMENT, RECEPTACLES, HOOD ETC. Value of Electrical Work: NRES: $27,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie The granting of this permit does not pre construction or the performance of work. Signature: Print Name: Fees Collected: $696.12 National Electrical Code Edition: 2008 Date: 601i t114� ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. me to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Date:, ,A5 /d'c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0787 Printed: 10 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htv//www.ci.tukwila.wa.us Parcel No.: 3523049123 Address: Suite No: Tenant: 17950 SOUTHCENTER PY TUKW MIZUKI JAPANESE BUFFET PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0787 ISSUED 10/05/2010 10/18/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: /// 6 /d /O doc: Cond -Elec EL1 0-0787 Printed: 10 -18 -2010 CITY OF TUKWWA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. l D— 0 7g 7 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1 950 (;l7 UYOUZ k Vk Wa Tenant Name: (U1 C 3 (1 1 31 ese g U.�!�P�� Property Owners Name: U Mailing Address: King Co Assessor's Tax No.: 3S,L3oLi— (Z3 Suite Number: Floor: New Tenant: 13k7.—Yes ❑..No City State Zip CONTACT PERSON - Who do we contact when your permit Is ready to be issued Name: 3-0L1U2— (A.Y\ Day Telephone: aC)6 2 351/ "323 Mailing Address / $ <02 3 7 . Df . S 6. 3o7,/1 tom- ?86)2- City State Zip E -Mail Address: f ' '1 (J t u e sri-( .0 y a keo . C_A; 14•A Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: LLP IUD Sc Q c liL t c. 1 rl C Mailing Address: gad? 376± Dr. 5,E. y5ot eJ f LuAt Contact Person: j �LGZ E -Mail Address: b G Contractor Registration Number: U'w.1/� . €_ �, _I, go12 --- City State Zip Day Telephone: qc6) JSy-A 32_ Fax Number: / Expiration Date: %J/20/ 041 0 Valuation of Project (contractor's bid price): $ 7 dd c Scope of Work (please provide detailed information): n to.k-tpld ) f22C-Pri tC.ct kco b Will service be altered? 41.--Yes ❑ No Adding more than 50 amps? • Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator 0 Fire Alarm ❑ Telecommunication Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications\Fonns- Applications On Line \2010 Applications \7.2010 - Electrical Permit Application.doc bh Page 1 of 2 es ❑ No Tenant Improvement ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: P Mailing Address: /'&2 3? th AP t(%Q S • 6 Date: /0 —5--1 0(0 Day Telephone: '0 (:$) a5-4-3932._ &TAO W ego 12 _ State Zip Date Application Accepted: 10 Date Application Expires: Staff Initials: Opt? H:\Applications\Ponns- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 1 J�w1�A wq City of Tukwila . Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone : 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049123 Permit Number: EL10 -0787 Address: 17950 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 10/05/2010 Applicant: MIZUKI JAPANESE BUFFET Issue Date: Receipt No.: R10 -01988 Initials: WER User ID: 1655 Payment Amount: $696.12 Payment Date: 10/05/2010 03:48 PM Balance: $0.00 Payee: UNIVERSAL ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8053 696.12 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 556.90 000.345.832.00.00 139.22 Total: $696.12 doc: Receiot -06 Printed: 10 -05 -2010 INSPECTION NO. INSPECTION RECORD Retain a copy with permit zio PERMIT NO. -CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: j Type of Inspectiio /n: Address: 1-'79,5 d ,5:19'a771,147' r-A . /71 Date Called: Special Instructions: Date Wanted: !//.7 —/% a.m. p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: Q I t-- ' t J/k L A47' Date: V/97`.. r7 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. j INSPECTION RECORD Retain a copy with permit INSPECTION NO. + PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188' (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1 i U it i -rA Pik, ,,�-mg- 1 Type of Inspection: -° r i0,0 ddress: 1179. / Op,, ,o ' . /ld Date Called: . . /,.) s*9Ruc. -rpwa As Special Instruct°lons: /) �/(,•� 1 7:4,5-5,0-4. �•a%6'wYJ 141'0o�' Date Wanted: / %%, a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: e91"`i C / / t r-i - / 41»i 7 gr` Fis %'.l CI di 0 rr t- . /,.) s*9Ruc. -rpwa As %f ill. h �-i S7 1 7:4,5-5,0-4. �•a%6'wYJ 141'0o�' KfCC7'%� f AC4tT3 �j //t/✓L �D4.3 /.,.ii7.,,int iO di-- ryes -no) Inspector: EC - Era 5pe &e,m,b7- Date: REIN T ION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6Ao-cts7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 pi (206) 431 -3670 Project: ��// Type of Inspection: /00) Address: rii5.0 5,,e_ ° Date Called: Special Instructions: Date Wanted: 6 3o a.m p.m. Requester: (((( Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: if pAp 64TM r DLA D5 Date: T7 REINSPECTIONIFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 6`!D" D7 7 INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: � � ���� Type of Inspection: 70®/ Address: 116150 5.e. . Pl- Date Called: Special Instructions: Date Wanted: C.m. Requester: Phone No: Approved per applicable codes. • El Corrections required prior to approval. OMMENTS: 0 i's7 un0fA.Z Ca4p4(r, Inspector: i& Ali,; n REINSPECTION FEE REQUIRED. Prior to next inspection. fee:must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 401 (0 'fa p(kr\e_,L__ \ voLTcer(z.. /1ov 60 14 \t.) FL E COY pcin0„), kr\ QWL I,ockA PrArrqt M. 2- \ Cr 4c7Ot 3 / wob 5 101(4)01 toot 1:4110.CA !II•100 :1-193t.t§ 11/ . kctc\riell Mob 13 -To bock :POOL con,m110) . 0 Oei) Po4 .020 Scuvlw c ,r14)) 11 $Q.KvAw ic)\ re ZtRsa- vzo..20 021 pix*--.Tiwkek. 120v .20 ?ogv gv cC „20Z1/ eo klov -213 )3 110ktR- XI .29 1-4 -1-01-t& woatS -ToTek ckyvvy)S NFPA '70 - OCT 1 3 2010 Li 3 --Itity of Tukwila BUILDING DIVISI „Zogy 2 c) . VapoR-goot> Li thk\s'N Waggir TM-Nio b iloott> 10. Door D5Fe...e.,. 11,, boor c-Rmet. 14 cllespy- ktFtY S Rxte__ I?) ,20 *AR F6.hwartiek. 1 O 020 Acto yyt.oktk, lo c, 2.400 4 co.tioa make_ Do o t Eco Itovb 044 020 02080 31 4001> c2c., 07080 (S 340 120 15 ,2A/C01 34,o Wo .20 120 2s3 1,1440 LL*) 12o .,2.0 1)._co 42944_8 wcocts LoN8 t .11 /3,41.5A trIpL Qsk711.011 hQs. -1*,k\ey) tiz.C(Aits ,f1clotiv‘c‘ rieu:Dtt kcAut. C.) 1 DIFF)von. G) ••••••••■•••■•■.......=••••••• 9-Z;10. RECEIVED OCT 06 2010 PERMIT CENTER tIo v63)36.9.. ji�Pv 1,+w p aooRmP Cud -Cu, a; 3 unDcst cownitk.(001 R,. 12v 5 urn Tea, Tea, jr c ,n Ada. FOu V \ 1 C�ts�� �n ►11er� 13, pYc T bety (so 620 13 trop ►n ReFeUkJ-- I i la>' Roo I) 1 of � . I/' goot. Io10 pot .�� 14,,01 Foot WaY14 L gag .23 Kci F-co0 wo►Ymek_ d ?3 DyroP 1h 4o1 ;Food Ktt 14 dace Drop Nol F k0 t4 aoo o2v l o00 2d ►1.40 a ° 53® 2c 5,33o \S 84t6 o'ts144® 1440 o 940 is 12.451) tL4$ IS 104° cow .2p aOoO 02 .2 ,3S6 ) e2. \ DM) i Y\ NO1 Foots Drop to AolfuM ) So u4 wairtneZ S Sooi tiocaPAP- LxiOrrna._ lz tomb'► over 1�{ comb our 1 cc of oven 5�� SIN 1.0 t,hni &)Qom. V e )-r)4.1=) 15 Soo log 15 5oe is Soo .24) ► 3" SOa Igo IS Goo aot ..40 3c 6� c0 € o% 3e Q. ,0 100 12o ;® 1,00 ,23, 7,2c ' r6To , W0,7(1.S 5o, ol(D W T o o L 1 M p So j o1 C =- 024 0 X 1.13 z /39 pPI p koi- 1. 1\30 beS2Calri huZ br cka_. c,tos,$),:ii-vSVICOrtnA, r\Q(CtitiLt\MaL t‘Pki.k. (W64.) &escig,JL kkrAit, 11 eY0c3kon. (kmz..oasSok, - C21c6) 35 -39371-- 013.0eiL 0W3if 24 v 3s 4 \,0 < EYA5T1 cisk,IntL> PattL,..aciatc Lock_ct CALC.mitZto'N 0,3 3 crT&T 19.c, 5 Fttp7 tsfiso.4. 1,40 Dx)?‘in ■401R1 l o Oror tn Foot RD 15 120 1 1: broe 4.0T FOC6 a \S- 0,0 13 PEP: tn' Not Coo t5 12Q (5 Dro in k-kol FooD PrD tS° u4? 17 cs3cup- t?.c, 621 tiLADtr cow'freg4 ceoLek- 126 23 ..Pt,11DR..a- cs,f-t4C1f-FLcsy)1..ea.. •2,p 25 ‘AsOtIrcuakir. coiztkR, L210 too 1,20 f M2.1‘c • LooZ 20 020 c20 1440 a ack. (AoLe_ti. psz> 4.4 0 kqe.Ya cpk&e._ 8$0 cycxon 00 M tr4 ek. AS00 1.0 tAnYk f ktRY 30 Ado L. work:1AT ile_Feir 30 ,ASto imovk_ -to P-e-FeY 30 a500 ktoovk Orof 20 kk) koza-V- Co01,0?... cooa- 2.0 P-00 22 walk tn. Fketr4, •tait) .24 (AALOL ‘n ct.e.tA 120(.) 2c, cAst 0143 4204,0 8 suA; do 30 5c Cc 1/ 130c._. t 2o walets 5 t,30 txr- ToTai, cLoyps 1)%3ow 1144 iNmps ka.Q12. I )o 1)it..9..a,I6P) 11,c444 bttil Takw oz. 1 \(\UaY(04,.. olrf 0 areAictv- VoLinOz_. (3fc')wn t.,1:erj.tYiL, irc. Aqo 105k (44o (4N0 1440 t44- 0 \q.L1-0 14,44 .13,2 a 3,32. S-60 15%o ocz• tNr- 04 -01 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JAKE YUN 18602 37 DR SE BOTHELL WA 98012 RE: Permit No. EL10 -0787 17950 SOUTHCENTER PY TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 05/29/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and /or receive an extension prior to 05/29/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. EL10 -0787 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • ukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director October 8, 2010 Jake Yun 18602 37 Dr SE Bothell, WA 98012 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL10 -0787 Mizuki Japanese Buffet —17950 Southcenter Py Dear Mr. Yun, This letter is to inform you that your permit application received at the City of Tukwila Permit Center is determined to be incomplete. Before your application can continue the plan review process the attached /following items need to be addressed: Building Department: Jim Benner at 206 431 -3679 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, )&,,JLP Bill Rambo Permit Technician Enclosures File: EL10 -0787 W:\Permit Center \Incomplete Letters\2010\EL10 -0787 Incomplete Ltr # 1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Tukwila Building Division Jim Benner, Electrical Inspector Determination of Completeness Memo Date: October 10, 2010 Project Name: Mizuki Japanese Buffet Permit #: EL10 -0787 Plan Review: Jim Benner, Electrical Inspector The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide one line electrical service diagram including panel schedules, service conductors, conduit size, and overcurrent. 2. Provide load calculations. 3. Ensure 1 foot/candle emergency lighting (measured at floor) along all paths of egress. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. PERMIT COPY. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0787 DATE: 10/12/10 PROJECT NAME: MIZUKI JAPENESE BUFFET SITE ADDRESS: 17950 SOUTHCENTER PY Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ANC, �Ole' (0 BuTding Division Public Works Fire Prevention Structural C Planning Division C ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete, Comments: Incomplete ❑ DUE DATE: 10/14/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route `f-'. Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/11/10 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • E L r ` COP'S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0787 DATE: 10 -06 -10 PROJECT NAME: MIZUKI JAPANESE BUFFET SITE ADDRESS: 17950 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 0—`0 ip Building ivision Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-07 -10 Complete / - Comments: Incomplete Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: (6 10 LETTER OF COMPLETENESS MAILS : Departments determined incomplete: Bldg "Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROyTING: Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -04 -10 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 10/12/2010 Plan Check/Permit Number: EL 10-0787 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner CIiY0FE7UKWILA OCT 122010 PERMIT CENTER Project Name: Mizuki Japanese Buffet Project Address: 17950 Southcenter Py Contact Person: Jake Yun Phone Number: 206- 354 -3932 Summary of Revision: Per conversation at counter — plans are okay as submitted. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: f►v`' Entered in Permits Plus on ‘0 \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P ter Friendly Page Electrical Contractor A business licensed by LW to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company UNIVERSAL ELECTRIC INC 2063543932 18602 37Th Dr Se Bothell WA 98012 Snohomish Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602183480 Active UNIVEEI985D2 Electrical Contractor 3/22/2002 3/22/2012 General Unused License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVEECOO2P4 UNIVERSAL ELECTRIC CO INC Electrical Contractor General Unused 10/24/2000 10/24/2002 Archived UNIVEEC032L6 UNIVERSAL ELECTRIC CO Electrical Contractor General Unused 6/2/1997 6/2/2001 Archived YUNSCI "0880N YUN'S COMPANY INC Electrical Contractor General Unused 9/15/1992 9/15/1998 Archived Master Electrician INFORMATION License YUN`TTJ968PQ Name YUN, TAE JAKE Status Active Business Owner Information Name Role Effective Date Expiration Date YUN TAE, JAKE Agent 03/22/2002 YUN TAE, JAKE President 03/22/2002 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SE2828 03/13/2002 Until Cancelled $4,000.00 03/22/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 10/18/2010 • it 42 y ,'V .i 6< :. h "z`t sham; +? E RL ELECZRZC ZNC y� +Wr`xa AMR 1111 1111911MINT all ±fp��f�1011.iii111101 X+r•;.'11` _`A'4•Z t* 1.5 Ft •CAStulN`F MACK AS PS, ABC.. . 26062506i 4.10$01Y ;.gym« «PPP, ;P, . • ..P, . NW..* . .*„ 1 dM4SR MW 4P '[lOA NaOYOf!! ::"':::;;`,..,..'''',,,,,,,,,,-",,;.,„..... 1 f o blatiMPIORMSKORO .P • •O O4 WP! •M'M km' -Mmmo> +PUNK' Mommwm. w cows. amam 4 m $ :�. 1�'Y✓'.m <:: ••• c >y s"'s.'4''�v4C.,;•1,e .1. 44.4v,&' N.; oY' wcxi t4. s k�. � Sea -szN ?'a "+x.t co v�wc'"?� mm, r. oar'. q•F • • REVISIONS No changes shall be made to the scope of work Without. prior approval of • Tukwila Building Division.. • . NOTE: Revisiens wits require a newwptan submittal . and may include additional plan review. tees. • CURVE DATA . TA LE tTMtz`ii ••+. c aortioesomessmcium WWI- It o t a. ax IN IMIVAAle 11� IIMErtz aAmo ?EMI R_, n=om Jnr 2.Mkr :107:t�l �.: airEillOrtirfigsZ 11111 ' .:. imuw.4Y11 _ C t . Permit No., •Lj0 -07 S7 P! 11 review approval is subject to errors and omissions. • . 1:: rovat.of construction documents does not authorize t F ,violation of any adopted code or ordinance. Receipt c approved Field Copy and concr `. is acknowledged: City Of Tukwila . BUILDING DIVISION 0 POS 8J23 square feet with of exterior addition SEPARATE PERMIT REQUIRED. FOR: lErrAechaniCal • OE . t , Umbiry s Piping City of Tukwila BVILOINo DIVISION REVIEWED. FOR COMPLIANCE WITH NFPA70 , NEC OCT 1 3 2010 amity otTukwita BUILDING DIVISION. 00 square feet of Tula 1NG DIM EIVED OCT o. 6 2010 PERMIT.CENTER MONARCH TRADING CORPORATION RESTAURANT 'EQUIP NT & DESIGN CONSULTANT 946 SOUTit DORIS St.. / SEATTLE / WA 98108 TEL 2O6. 763 --6181 / FAX Sob. 763 -6186 LICENSED 1; INSURED 01 BONDED CONSTR. CONTRACT NO,i DMONARTCO6501 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION .WHICH ARE NOT TO DE DISCLOSED OUTSIDE THE ;RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR. WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. PROJECT MIZUKI JAPANESE BUFFET 17950 SOUTHCENTER PARKWAY TUKWILA, WA , 98 188 DRAWING TITLE * SITE PLAN REVISIONS No. Date Description PROJECT DIRECTOR PROJECT ARCHITECT 4 . ............................... PROJECT CAPTAIN PROJECT NUMBER APPROVED BY CHECKED BY DRAWN BY DATE JUNE NE 10, 2010 SCALE DRAWING NUMBER P.A2OFF 16 ••K • NOTE: ALL MORE;; TO CONFORM N11TH THE ABOVE CODES OCCUPANCY 15 RESTAURANT, GROUP A -2 5151 SQUARE FEET OCCUPANCY 15 RESTAURANT, GROUP B 25S0 SQUARE FEET NO RATED SEPARATION REQUIRED FOR CROUP B AND GROUP A =2 OCCUPANCY EXISTING BUILDING 15 ONE STORY A1TH PROPOSED ALTERATIONS TO EXISTING STRUCTURE M$rikier Blvd. 2006 INTERNATIONAL BUILDING CODE OCCUPANCY AREA DINING ROOM OCCUPANT LOAD FACTOR: OCCUPANT LOAD: A -2 (5516. sf) 15 234 OCCUPANCY AREA (KITCHEN) 5 (2166 6f) OCCUPANT LOAD FACTOR: 200 OCCUPANT LOAD: 14.5 CONSTRUCTION TYPE: V -A OCCUPANT LOAD: TOTAL 241 DfNINC SHEET INDEX ROOM KiTCHEN 1NA171N6 AREA OFFICE AREA e05441 BAR BATH HAL,LINAY HOMENS BATH HEN'S BATIK UNISEX BATH TINKLE ROOM MECH ROOM TOTAL 5516 241 a 241 315 232 2% 215 s-r 102 02 fit. FT. (1) A 1 COVER PAGE/PROJECTDATA (2) _ A 2 S1TE PLAN (3) A 3 DEMOLITION PLAN (4) A 4 FLOOR PLAN (5) A 5 EQUIPMENT PLAN (6) A 6 EQUIPMENT SCHDEULE (7) A 7 BUFFET ELEVATiON/RESTROOM DETAIL (8) A 8 EGRESS PLAN (9) A 9 CEILING / WALL SECTIONS 00) A -I() REFLECTED CEILING PI..AN (11) A -11 WALL SECTION/BUFFET DECOR (12) A D -1 ARCHITECTURE DETAIL (13) S 1 STRUCTURAL NOTES (14) 52 EXIS1T NG FLOOR PLAN (15) 53 GREASE INTERCEPTOR DESIGN/ DRIVEWAY DETAIL (16) 54 NEW STORAGE FLOOR PALN (DELETED) DEFERRED SUBM.U'TALS: - BY SUB-CONTRACTOR MECHANICAL - GAS, PLUMBING, HVAC, KITCHEN EXHAUST ELECTRICAL FIRE ALARM FIRE SPRINKLER � iNIvERSAL ELECTRTi C. zc . Main Japanese I3aftet 17950 So theenter Paciokay • f f ormerlyThe Shane re t ompany) FIRE . CODE GENERAL NOTES 1.ADDRESS NUMBER SHALL. BE PLACED ON THE BUILDING Its A POSITION TO BE PLAINLY NUMBER AND LEGIBLE MWITH FRONTING SHALL BE AT LEAST 4 INCHES NLlts�tBER SHALL CONTRAST HIGH. VERIFY WITH FIRE MARSHALL FOR LOCATION MOUNTED. 2. OWNER, CONTRACTOR THE DEPARTMENT KNOCK BOX AS DIRECTED OCCUPANCY, ARE MARSHALL. OWNER SHALL. PROVIDE MASTER K,EYSFOR THROUGHOUT OWNER, CONTRACTOR TO PROVIDE FIREEXTINGUISHERS, WITH d D OF L I SELECTED, NSTALLED AND MAINTAINED IN ACCORDAN CE AND PER NFPA RULES. 1 0. GC TO RELOCATE AS REQUIRED A. FIRE EXTINGUISERS SHALL HAVE A M1NIMUtk1 RATING OF 2A -1OBC WITH CURRENT SERVICE TAGS ATTACHED. B.I REE REAILE LOCATED ALABE USE TSEEi WHBDY ACCS SIBLLE AI IMMEDIATELY AVILTO HELOCAIO ds SHALL BE ALONG NORMAL PATHS. OF TRAVEL. FIRE EXTINGUISERS SHALL NOT BE OBSTRUCTED. C. FIRE EXTINUISHERS SHALL BE HOUSED IN CABINETS W RI STN" S€TALLEE`DD ONDT E HANGER GER OR BRACKETS. FIRE EXTINGUISERS HAVING A GROSS SHALL BE INSTALLED SO THAT ITS TOP TOT HOBTHA fl IN M L B O E TH E OOR. FIRE EXTINGUISERS A CRCSW � MORE 6 ITS TOP € NOT MORE TH AN 42 INCHES ABOVE THE FLOOR. THE BOTTOM OF THE FIRE EXTINGUISHER SHALL BE. 4 INCHES ABOVE THE FLOOR MINIMUM. D. MAXIMUM TRAVEL DISTANCE TO A, FIRE EXTINGUISER SHALL NOT EXCEED 75 FEET. 4. REFER TO FIRE DEPARTMENT PLAN REVIEW REPORT FOR A.DDIONAL REQUIREMENTS. A CLS 1BL1 VICINITY .... MAP PROJECT LOCATION NO change t i ii T to the scopo of pork without prim approval of . • Tu imlja Building •Divisi n. NOTE E: R v€ signs will require a new !en ub€ ° =tt €. arid r na.i include .qci iit'ann 1 plan rwx ' e e v5. 1. ALL NEW CONSTRUCTION INCLUDING � S DOORS, CABINETRY 2 O6 Bc CHAP IMF PLUMBING 'FIXTURES TO MEET THE ACCESSIBILITY REQUIREMENTS • 2. ALL. EQUIPMENT FIXTURES, .AND CONSTRUCTION C O LQUDTO BE ACCESSIBLE TO MEET THE ICC/AMSI M 17.1 - 2003. STAND STANDARDS RE ADA A. PROVIDE OPERABLE LEVERS FOR BARR1ER-FREE ACCESS ALONG ROUTES OF TRAVEL AT BARRIER -FREE ENTRANCE, B. MAXIMUM TRESHOLD HEIGHT TO BE 1/2" . ALONG ACCESSIBLE ROUTE. OF TRAVEL PER SECTION 4.04.2.4 SECTION C. PROVIDE M1NIIUM 1 a." BEYOND STRIKE .JAMB 1��LF I�TCI -LATCHING, ��, PRO�IDI•�.rs�I�N��, ��UI�1.� STI�II�E. 40� -.2.3 IF DOOR 15 SELF CLOSING JAMB ON OPPOSE T SIDE OF 'DOOR SWING. FIRE EXTINGUISERS SHALL NOT BE OBSTRUCTED. D. EXCEPT FOR APPLIANCES, SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPIiNG, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS .MAXIMUM, E. COUNTERS FOR SALE OR DELIVER OR DISTRIBUTIO GOODS TO THE PUBLIC SHALL -AVE A PORTION OF CCU OFROINCHES LONG MINIMUM BY 36 INCHES MAXt141UN ASH ABOVE THE FLOOR. A PORTION OF THE RECEPTION COUNTER SHALL BE ACCESSIBLE' TO THE • DISABLES.' 3. PER 2006 18C 3409, ALTE•RATIONS ING AN A N PRIMARY FUNCTION • BEYOND IL ABOVE. THE ROUTE TO THE AREA �F PRIMARY FUNCTION BE ACCESSIBLE. THE COST OF THE ACCESSIBLE ROUTE IS NOT REQUIRED TO EXCEED -20 PERCE CE OF ,j OF THE COSTS OF THE ALTERATIONS AFFECTING THE AREA O P RIMARY FUNCTION. ION. x SEPARATE PERMIT QUEER FOR fitharital umbino as lilr1 City of Tukwila 14AK3 .. DF MSIGdl GENERAL NOTES 1.'Gen.rol Contractor shall verify ell conditions and dimensions at job -site, also, review lease agreement with landlord's requirements or con - ditions. If any discrepancies are found, General Contractor to notify the .Architect/ f weer. 2. All construction work must confirm to .current local codes and au- thorities for building and health departments. 3. General Contractor agrees by accepting contract and starting work that he shall assume sole and complete responsibility for jab site conditions during the course of construction including safety of all persons and property. This requirement shall apply continuously and not be limited to normal working hours. General Contractor shall defend, indemnify and hold owner. architect, designer, engineer and landlord harmless from any and all liability rent or alleged, in connection with the performance of work on this project. General Contractor shall show proof of worker's compensotion insurance as required prior to issuing a permit.. 4. Additional on site fire protection during construction to be provided as required by fire inspector or deportment. Maintain existing fire sprinkler system if applicobte to project. . 5. all materials stored on site shall be properly stacked and protected to prevent damage and deterioration until use. Failure to protect materials myo be cause for rejection of work. 6. General Contractor and subcontractors shah be responsible for locating, maintaining. relocating and /or removing existing utilities. 7. General Contractor to provide larger stud wolf as required for installation of .plumbing, electrical, structural, etc, items. 8.. Existing aneteriial on demising or interior partition wafts shall be removed by sub-- contractors to allow installation of new work, such as e €ectricot outlets, plumbing lines, etc. After work has been completed, tested and approved wails shall be. covered with 5/8 "type, "x" gypsum board, fire taped and prepared for new finishes. General Contractor shall brace entire structure, stairs, storefronts, etc. os required to maintain stability until complete and functioning os o finished instal- lation and . unit. 9. M workmanship and materials are subject to the approval of the architect, designer and owner. 10. General Contractor to install 2x blocking or 1/2" plywood backing in stud walls for installation of equipment, decor, etc. as required. Verify all location with equipment contractor and decor contractor. Although typical equipment and decor details will be provided, it will be the responsibility of each subcontractor to provide integral, complete, final instaliutibn which meets local codes and design concet. 11: General Contractor to provide hand fire extinguisher of type and size os required by code and locate as indicoted on drawing (for restaurant use); provide proper indentificatioo signs. install at height not to exceed 5' -O". Exact number /location by fire inspector. 12. Exit doors shall be left unlocked during all business hours and shall be opened from inside without use of o key or special knowledge or effort. Panic hardware to be provided os per focal code requirement. Also, General Contractor to provided signoge ,over eoch exit door, e.g. 'This door shalt be remain open during business hours" or. " Exit door ". • 13. Provide exit sign iliumnation per UK Spec 3312 (c). 14. General Contractor to .provide an occupancy sign with maximum person amount as determined by fire /building deportment mounted on the wall. 15. Public areas, 'toilet, and public circulation oreas shall meet all handicap requirements. .All required toilet accessories, equipments, fixtures shall meet height requirements. floor plans will allow handicap person full .access to all restaurant activities (dining, bar' service, toilet, exits, etc.) . . REVIEW COMPLIAK NFPA 70 -NEC OCT 13 2010 City oft-Wm/11a BUILDING DIVISION Permit This set . kept keptat : s t , c i•Ici du ....Of T ivi all s I:.ss 3. I � Ming Official ntative. DI r D V SIQ:T a. i� z� e PROJECT DATA: PROJECT NAME: MIZUKI JAPANESE BUFFET RESTAURANT SITE ADDRESS: 17950 SOUTHCENTER PARKWAY SOUTH TUKWILA, WA , 98188 . Tenant contact: JOHN KM WAH 1426 S. 324TH STREET FEDERAL WAY 253 - 88641943 APN: 3523049123 . Legal Description: 3523049123 LOT A. of city of Tukwila short plat L99 -005 3 recording #2000013190003 Zoning: COMMERCIAL Current use: Retail (vacant) Building type: Masony Built: 1999 . Proposed Use: RESTAURANT Occupancy type: A -3 . Construction Type: 1;;Ttr - V 4_ Siesmic zone: 3 Code: IMC/IBC 2006 Tenant Square footage: 8523 s# Land Parcel: 2.2654 Acres (including neighboring Newport Seafood Restaurant. Theater and Parking) Landlord: Madison Investment LLC 1276 N 15th Ave, Suite 103a Bozeman, MT 59715 Sewer -- 4" in building, 6" at west corner Water: 1.5" 60 psi Power: 800 amp 120 v/208 v/ 3 phase Insulation: R13 walls Roof: Metal with foam board above AC: existing 5 gas units each 99,000 btu/hr, 31.5 tons total Scope of Project : - EL1Q 0787 1) To change use from a vacant retail space to a full service food service establishment per plan. Approval application has been submitted to King County Health Department under a separate cover. 2) Establish use of a buffet style restaurant with approximate seating o 250 persons 3) Propose to add to existing structure an attached covered enclosure at north side with an area of 490 square feet for garbage compactor and dumpster as well as cold storage per plan. The exterior of the addition area will match existing design with stucco masonry and sane color. 4) Two side entrance door with an waiting are enclosure will be added to the store front entrance area per plan. Application this permit: .Building Tenant improvement permit. With structural design Outdoor Grease Pretreatment Intercept:: Deferred applications: a) Mechanical permits including HVAC addition upgrade, gas piping, b) Plumbing c) Kitchen Exhaust Range Rood d) Fire Suppression e) Building Fire alarm 1) Fire Sprinkler MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT & DESIGN CONSULTANT 948 SOUTH DORIS St. / SEATTLE / TA 8810 TEL 206. 763 -6161 1 FAX 208. 769 -6168 LICENSED s INSURED * BONDED CONSTR. CONTRACT NO.: MONARTC065O1 THIS DOCUMENT ENCLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETARY TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL ARRANGEMENTS WITH MONARCH TRADING CORPORATION. PROJECT MIZUKI JAPANESE BUFFET •17950 SOUTHCENTE.. Z. P . Y. TUKWILA, WA 98188 DPAWING TITLE PROJECT DATA. NOTES SITE .MAP REVISIONS, No. Dote Description VIEWED FOP OMM Contractor: Monarch Trading Corporation . License no..MONARTC065 iQ1, expires 3/14/2011 . Contact: King Lee 948 S. Doris Street Seattle, WA 98108 Work :- (206) 763 - 6161:1 (Mobile) © 206)396 -3173 Email: King ®J%4onarebtradingeorp.coni PROJECT DIRECTOR .TL PROJECT ARCHITECT PROJECT CAPTAIN PROJECT NUMBER APPROVED BY CHECKED DRAWN BY .TL.. Y RECEIVED• OCT 06 2010 PERMIT CENTER SCALE 2" 1,E DRAWING NUMBER P. A. 1 OF I6 Mizuki Japanese Buffet 17950 Southcenter Parkway S Tukwila, WA 98188, Item Qty Description 1 3 11' Hood, type 1 with exh. MUA fans 1A 1 Fire suppression system 2 Spare numer 3 2 Gas rice cooker 4 1 10 burner range w oven 5 1 7 burner Wok range 6 4 Gas fat fryers 7 1 Gas convection oven, double deck 8 3 1 comp. Hand sink 9 1 Two door reach in Refrigerator 10 5 S/S work top table, 30 "x60„ 11 2 Sandwich prep refrigerator 12 1 SIS work top table, 30 "x36" 13 1 S/S Double tier pass thru shelf 14 1 Floor Mixer, 30 QT 15 1 Flake Ice machineon Bin 15A 1 Ice storage Bin 16 2 Cube ice maker on bin 16A 1 Ice storage Bin 17 1 Mop Sink, floor sink 18 2 Gas water heater 19 1 2 comp. food prep sink w 2 DB 20 1 1 comp. food prep sink w 1 DB 21 4 Floor model hand sink 22 1 Type Two vapor Hood, 3`x3` w fan. 23 1 Dishwasher for glassware. Low temp 24 1 Clean dish table, 6 ft , right side 25 1 Soiled dish table with prerinse sinks 25A 2 Pre -rinse faucet unit 26 1 Type Two vapor Hood, 3`x5,5' w fan 27 . 1 Dishwasher double rack. Love fernp 28 1 Clean dish table, 6 ft ,Ieft side 29 2 Dish rack dolly 30 1 wire shelving, 4 tier 31 1 1 Comp Soak sink., no drainboard. 31A 1 Wall mount faucets 32 1 3 comp Wash sink w 2 drainboard 32A 2 Wall mount faucets 33 1 Three door reach in Refrigerator 34 1 One door reach in freezer 35 1 Two door reach in Refrigerator 36 1 16' Hood, type 1 with exh. MUA fans 36A 1 Fire suppression system 37 1 Two comp, food prep sink 37A 1 Wall mount faucet 38 1 S/S work top table, 30 "x36" 39 2 Bun Pan Rack 40 1 1 Hole wok range 41 1 Combi Oven on stand 42 1 Radiant charbroiler 43 1 1 comp. food prep sink w 1 DB 44 1 Insulated food warmer 45 1 Cube ice maker on bin 45A 1 Ice storage Bin 46 1 Drop in Hand sink 47 1 Ice storage bin 48 1 Coffee maker 49 1 Sake.Dispenser 50 1 Undercounter Cooler 51 1 Twin Tea Urn 52 1 Soda Fountain 53 1 Cashier/Walt Counter 54 1 Glass chiller 55 1 Draft beer cooler 56 2 Drop in refrigerated unit 57 1 12' Hood, type 1 with exh. MUA fans 57A 1 Fire suppression system 58 1 Hot food warmer 59 1 60" thermo Griddle on stand 60 36" Radiant Charbroiler 61 1 Drop in hot food unit 62 1. Drop in hot food unit 63 2 Soup warmer, drop in, 11 QT 64 1 Rice warmer 65 2 Carving station with heat lamp HEATED DISPLAY SHELF 66 1 Drop in hot food unit 67 3 Drop in hot food unit 68 2 Ice - cooled Drop in salad unit 69 1 ice - cooled Drop in salad unit 70 1 Cake display granite top 71 1 Refrigerated Case 72 1 Icecream dipping cabinet 73 1 icecream dipping well 74 1 One door reach in freezer 75 4 Work Top Refrigerator 76 1 Chef table 30x 60" w drop in sink 77 1 spare 78 1 Walk -in cooler, 6'x85(8` 79 1 Walk -in freezer,85:12`x8' 80 1 Walk -in freezer, 6'x15x8' 81 3 Walk -in shelving 82 2 Dry storage shelving 83 1 Locker 84 1 Garbage Compactor /dumpster 85 Spare 86 Spare 87 1 A comp, food prep sink w 2 DB 88 .3 Undercounter Cooler 89 3 Sushi Case, 60" 90 1 Ice - cooled Drop in salad unit EQUIPMENT SCHEDULE Make CaptiveAire Amerex Reinai American WIN Pitco Duke Turbo Turbo TRUE TRUE Turbo MTC Thunderbird Hoshizaki Hoshizaki Hoshizaki Hoshizaki Fiat by Plumber RJ Fab Turbo GSW CaptiveAire AutoChior RJFab RJFab Fisher CaptiveAire AiitoChlor RJFab Cambro:.. Eagle Turbo Fisher Eagle Fisher TRUE TRUE TRUE CaptiveAire Amerex Turbo Fisher Turbo Winco Imperial Rational Crown Verity Turbo Metro Hoshizaki Hoshizaki GSW Rand& Cecilware Taiji TRUE Cecllware Coke Custom TRUE TRUE Duke CaptiveAire Amerex Duke MagicKitchen MagicKitchen Duke Duke APW TaHong Hatco HATCO Duke Duke Duke Duke Structural Concept Keivinator GSW TRUE TRUE RJ Fab Norlake Noriake Norlake Metro Metro Win -holt Waste Management Turbo TRUE. Hoshizaki Duke Model 5424ND PSP RER55N AR10 WIN CW10 35C E101G TSA- -18 -L1 T49 TSW3060 TSSU72 -30M TSW -3036 Custom ARM30 F801 M_HC 8300 KM1340MAH 81500SS MS2424 RJ- 1824 -2D18 TSB- 1 -24 -L1 1615F VH1 A4 CDT72 Custom 2210 -WB VH1 D2 CDT72 CDR2420 24x60 TSB- 1 -24 -N 3200/3962 314-24-3-14 3200/3963 T72 T23F T49 5424ND PSP TSA- 2 -18 -D1 TSW3O60. ALRK2O CRA1 SC62 MCBSONG TSA- 1.18 -L1 0539- CDS -11 KMD450M -H 8300 HS16151 9510-IC CS3 TSK130A TUC48 CL100 GC50 TDD3 AD-4M-N7 5424NDTPSP E303 1MMKG60 -E -NC FM636RMB4NC ADI4ESW ADl1 ESW 8M50 -11 D SJE20000 Utility 35K (2) btu/ 112 "Flare 380K btu/ 3/4" NPT 700K btu 1.5" NPT 100K (4) btu/ 3/4" NPT 80k btu/ 3 /4" NPT Hwicw /dw Cw /Idw Cw /Idw Hw /caridw verify Hw /cwiliw Hw /cwildw Hw /cw /dw Hw /Idw Cw /Hw /DW Her /Idw Hwlcw /dw Hw/cw /dw Hw /cwfldw Hw /cw /Idw Hw /cw /Idw 129K btu, 3/4" NPT Hw /cwlldw CW /1DW Hw /cw /dw Hw /cw /Irtw Hwicw /Idw CW/1DW 150K btu/ 3/4" NPT 901< btu/ 3/4" NPT GRSSR2O -DL7 7516 HBGB4818 ADI3ESW ADl5ESW ADI51 ADI31 HV56 Visidipper HS -DSRE T23F TWT72 Custom FL688•.R FL812 -F FL615 -F TSA- 2e18 -D1 TUC6O HNC150BA -R -S ADI21 Note: CW =Cold water supply, HW =Hot water Supply, IOW= Direct waste, IDW= Indiirect waste Cw /J0vv Hw /cw3 dw verify Hw /cw /Idw Elegy ctrical), 120/208v/60/1 ph (4) 120v /60 /1 ph/ 9 amp 120v/60/1 ph/ 12 amp 120v/60/1 ph/ 12 amp (2) 120v/60/1 ph/ 12 amp 120v/60/1 ph/ 14 AMP 208V/60/1 PH /10 AMP 120v/60/1 ph 3poep 120v/ 60/1 ph/ 20 amp 120v160 /1 ph awl 120v/60/1 ph/ 20 amp 120v/60/1 ph/ 1.2 amp 120v /60 /1 ph/ 12 amp 120v/60/1 ph/ 12 arnp 120/208v/60/1 ph (2) IOMP 208v/60/3 ph 30 Ar i 120v /60 /1 ph /2000w 120v /60 /1 ph/ 20 amp 120v/60/1 ph/1.8kw/15 amp 120v/60/1 ph/lkw 12Ov/60/1 ph/ 12 amp 120/208v/5.3 kw )2o vAeli &t 7 R45 120v/60/1 ph/ 12 amp 120v/60/1 ph/ 12 amp 120v/60/1 ph/ 1/4 hp /4 amp 120/208v/60/1 ph 208v /60/1 ph 5 Pin 208v/60/1 ph /2000w 208v/60/1 ph /500w (2) 208v/60/1 ph /500w (2) 120v160/1 ph/ 5 amp 120v/60/1 ph/ 12 amp 120v/60/1 ph /850w 120v/60/1 ph /1500w 120v/60/1 ph /2500w 120v/60/1 ph/ 18 amp 120v/60/1 ph/ 12 amp 120v/60/1 ph/ 2 amp 120v/60/1 phi 8.8 amp /790w 120v160/1 ph/ 12 amp 120v/60/1 ph/ 12 amp 120 /208v / &0/1 ph /20/208v/60/1 ph 120 /208v /60 /1 ph 120v/60/1 ph /10 amp 120v/60/1 ph /13 amp ALL EQUIPMENT ARE OF NSF Note Provide splash guard where needed to floor sink to floor sink Provide adequate need To floor sink To floor sink Provide splash guard where needed To floor sink To grease interceptor To floor sink To grease interceptor To grease interceptor To floor sink To floor sink /grease interceptor To floor sink/Splash guard To floor sink To floor sink To floor sink /Need backflow prevention To floor sink/Need backflow prevention To floor sink/Need backflow prevention To floor sink/Need backflow prevention To floor sink/Need backfiow prevention to floor drain To floor sink /Need backflow prevention To floor sink /Need backflow prevention To floor sink /Need backfiow prevention To floor sink/Need backflow prevention To floor sink /Need backflow prevention Need coed. Drain Need cond, Drain Need cond. Drain To floor sink /Splash guard To floor sink /Need backflow prevention ;TED COMMERCI AL MODELS HEALTH DEPT NOTES: L HOT WATER TEMPERATURE AT HANDSINKS TO BE AT LEAST 100 DEGREE BUT NOT TO EXCEED 120 F, INSTALL MIXING VALVE. WHEN NEEDED, HOT WATER MUST REACH ALL KITCHEN AND RESTROOM HAND WASH SINKS WITHIN 15 SECONDS, 2, HOT WATER HEATER MUST BE ABLE TO ACCOMODATE ALL HCi T WATER NEEDS. 3, DISH /UTENSILS WASHING EQUIPMENT 3-COMPARTMENT SINK IS MANDATORY REQUIRED. ( COMMERCIAL DISHWASHER IS OPTIONAL ) AND SINK TUBS TO BE LARGE ENOUGH TO ACCOMODATE THE LARGEST. ITEM TO BE WASHED, ' 4, ENSURE MALL, WINDOWS, DOORS AND CEILINGS IN KITCHEN ARE CONSTRUCTE.II WITH SMOOTH FINISH, NON-- ABSORBENT SURFACES AND EASILY CLEANABLE, ,5. ENSURE FLOORS AND FLOOR COVERINGS IN ALL AREAS ARE CONSTRUCTED OF EASILY CLEANABLE MATERIALS KEPT CLEAN, IN GOOD REPAIR AND . COVED AT THE FLOOR WALL ,JUNCTURES, 6. LIGHTING IS REQUIRED TO BE AT LEAST THIRTY (30) FOOT CANDLES AND BE PROPERLY SHIELDED. 7. PROVIDE HAND .SOAP AND TOWEL OR HAND DRYER FOR EACH HAND SINK UNIT: 8, ALL REFRIGERATION UNITS TO HAVE TEMPERATURE HOLDING NOT MORE THAN 41 DEGREE HOLDING, AND EQUIPPED WILL THE14OMETERS TO MONITOR TEMPERATURE OF PRODUCTS INSIDE THE UNITS, 9. ALL EQUIPMENT USED .MUST BE OF NSF LISTED COMMERCIAL MODELS, . 10. ALL ELECTRICAL /PLUMBING SYSTEMS MUST BE DESIGNED AND INSTALLED ACCORDING TO CURRENT LOCAL. CODES, 11. A PRE — OPENING INSPECTION IS REQUIRED PRIOR TO .OPENING BUSINESS TO SERVE PUBLIC, N'IVRSL: ELELTkIL AREA COOKING KITCHEN RESTROOM DINING HALLWAY OFFICE Counter top Buffet Counter Work counter Cabinetry MIZUKI BUFFET 17950 Sauthcenter Parkway, Tukwila WA 98188 Sushi, Sashimi, Tempura, Teriyaki Chicken, Salmon, Fresh Seafood, Crab Legs, King Crabs, Oyster, Hot Entrees, Edon Noodle Bar, Fried Rice, Salads, Soup, Fruit, Desserts and MORE!!! SATVI.'AV SVNDA Y ALL AY DINNER DVFFET ROOM FINISHING SCHEDULE WALL 24 GA SS FLASHING FRP behind sinks Semigloss paint throughout Marble tile Semigloss paint throughout FRP or SS Flasing behind sinks FLOOR Quarry tile Quarry tile Quarry tile Marble tile Stained sealed concrete Stained sealed concrete Semigloss paint throughout t_ Material used Cashier and wait station - plastic laminated wood construction Smooth washable Materials such as 16 ga Stainless steel NSF model Laminated or painted wood board Cove tile tile 12" Marble tile 4" Rubber 4" Rubber EL10- 07 87 CEILING Washable ceiling tile,2x4 Washable ceiling tile,2x5 Washable ceiling tile,2x6 GWB, Painted Open, Pained Open, Pained GWB, Painted material, (sealed natural stone is optional) REVIEWED COMPLIANCE V/ITH NEC OCT 13 2010 :TNNa N MUM VIS 0 �EvIEwE F EC M D ANCE • RECEIVED OCT 06 2010 PERMIT CENTER Alt MONARCH TRADING CORPORATION RESTAURANT EQUIPMENT k DESIGN CONSULTANT 848 SOUTH DORIS SL / SEATTLE / TA 98108 TEL 206. 763 -6161 / FAX 206. 763 --6188 LICENSED * INSURED w BONDED CONSTR. CONTRACT NO.: MONARTCO6501 THIS DOCUMENT sENDLOSES DESIGN CONCEPT, INFORMATION AND DATA PRIOPRIETAF2Y TO MONARCH TRADING CORPORATION WHICH ARE NOT TO BE DISCLOSED OUTSIDE THE RECEIVING ORGANIZATION NOR REPRODUCED IN WHOLE OR PART, EXCEPT BY PRIOR WRITTEN CONTRACTUAL. ARRANGEMENTS WITH MONARCH TRADING CORPORATION.. PROJECT MIZUKI JAPANESE BUFFET 1.7950 SOUTH .ENTER. PKWY TUKWILA, WA 98.188 DRAWING TITLE * * EQUIPMENT SCHDEULE * : MENU ............. .......... REVISIONS No. Date Description PROJECT DIRECTOR KTL PROJECT ARCHITECT PROJECT CAPTAIN PROJECT NUMBER APPROVED BY CHECKED BY DRAWN BY KTL DATE SCALE 1/2"=1'o" DRAWING NUMBER A 6 OF IC; JIER 5L sc:4)) ����11ICINC. LAMPPOST CONSTRUCT DRIVEWAY SIMILAR TO STEMS-09 10 "0" WIDE BICYCLE RACK Curb for abas - PU 5` SIDE WALK SIDE WALK • DELIVERY ENTRANCE NEW ENCLOSURE ' ROLL UP DOOR CIRCU R WALKWAY Dempster EXISTING PLANTER 10'8X1 018 NEW CUT OUT FOR ENTRANCE 25'4 -_ .fit OUT FOR WALK -IN DOOR 2' $•814" 18' 7 -114" 9'S -178" 18'54 WAIT AR9A STORAGE EXTERIOR LANDSCAPE AREA MAIN ENTRANCE 'MA RCH .7. i §k) INS io .PO.RAT:IOT ssatige EQUEZIT'S a It=484 Mullin dsoyr{ DIM SL /Si ; At BBl '!fn 2O L 7A:i —Ct61 / FAX 206. 763-60q 1.10t1N0wW • iN t U EEt' Oolczo i COMM' 801111011 NO.c attt la48 1 I ' HS DOCUMENT ENCLOSES I'iE: iGN OONOF.PT, iN ORMAflO!+1 AND DATA PRIOPRiE:TAP.Y TO MONARCH TriADINl OORPOF /,i'ION WHICH ARE NOT To B i)'s'caCLOSE° OUT.i.$r) -ne RE::^.z'aYIPJC ORGANIZATION NOR REPR(i"P GED ':N WHOLE OR PART, EXC f^`i" 8Y ?•'(sIO WRITTEN id)'N•!Rft::l'!,AL ABBANCEMENTq WITH MONARCH TRADING CORPOWION1 Mechaincal Ro 1845-7/8" EXISTING PLANTER 10'6X1O`6 Snee ee Guard-gyp) 5 afad Station KrZUKg "i FF ?r • a p € �a %s';7 ""s °S s, s. #'t. Diaz y, q s ,,,,,� A3.%i �: EQUIPMENT PLAN 2-a" ice - cooled Drop in ZITtlfie Pastry Elm 5g° CAKE 34" high ADA Cashier coon. 3' 5-1!8" Hot ADA Seats steam table she for clean suppi{ Employee rest room 4�T..IY1�['Xl ARCHITECT ICE MAKE 2O' -5" 11'8 -3/4" 5'.0" 85-O" M*33 h:, Type 11:3 o L d SUSHI EL, Glass washing Scullery 5` 4" Soiled table Refrigerated Drop in a REVIEWED. - COMPLIANCE ITH NFPA70 -N OCT 13 2010 Scullery 00 Dish PROJECTNUMBER APPROVED CHEC: ;D DRAWN 1LaAV2 1/4" =c_0" Ladies Dorn 22 -O" COMP If P Ice Bin $ cooler Sods a'KVCtiL of TLI Men's Room 5'-4" 1 EMERGEN EXIT W. PANIC HARDWARE RECEIVED OCT 06{2010 PERMIT CENTER 5'-4• 22' Cr 22' -O" 5' 4,: C!) 13'4" 119` -4n WWI JAPANESE BUFFET 17950 Southcenter Parkway Tukwila, Wa, 98188 EQUIP E N T PLAN SCALE: 3/8, °- 13 -0`= .224 seats 15 ��vzv�RS•� ELE-C7Q_ C IK)L (200351} 3 FAN 100 CFM VENT TO OUTSIDE / Emlergncy Battery Pack with Charger and Sealed. Beam Read LAW I'C / IBC 10€6 ID EMERGENCY LIGHTING Emezgncy Battery .Pack . . with • Charger and Sealed Beam Head JAW IFC / 'IBC 1006 NIGHT LIGHT 2 x 2 FLUORESCENT TROFFER x T-8 25w) SWITCH 2 x 4 FLUORESCENT TROFFER TO SPx5O (3xT- 832w) 96 W EACH. TOTAL 28 FIXTURES . TOTAL 2688 WATT NEW` DELIVY EN CE LARGE PENANT CFL w. 3 LAMPS x 60 w=180 w, ( 14 EACH) TOTAL 2520 WATT 6" RECESS CAN LIGHT ICPL 65W ,( 25 EACH) TOTAL 1625 WATT JUNO TC-2 LITHONIA L INDUSTRIAL LAMP, 64 W • , (6 EACH), 6X64= .384 'WATT MEDIUM . PENDANT UL BOW ( 39 EACH) TOTAL 2340 WATT SMALL DECOR PENDANT' UL LISTED 40 W ( 17 EACH) TOTAL- 680 WATT D905 DECOR ALL TAMPS ARE UL APPROVED FOR CFL LAMP USE NEW ENCLOSURE 1.9'' 8* ROLi. UP DOOR WASHINGTON STATE ENERGY CODE CHAPTER 51 ---11. WAC (2006 EDITION) CHAPTER 15 LIGHTING. AND MOTORS SECTION 1520 — PRESCRIPTIVE LIGHTING OPTION TABLE: 15 -1 UNIT LIGHTING ALLOWANCE (IPA) USE: RESTAURANT /BARS 1.3 LPA. (W /1t) ALLOWED: • 9023 SF TOTAL X1.3 = 11730 WATT TOTAL ALLOWED :. PROPOSED: SEE ATTACHED .LTG --INT INTERIOR LIGHTING SUMMARY TOTAL DINNING /PUBLIC AREA = 8317 WATT TOTAL `KITCHEN AREA = 2112 TATT TOTAL PROPOSED LUMINCOR DECOR PANELS, 4'KI* (14 EACH) 10429 WATTS. within range ACOUSTIC CEILING NOTE: KITCHEN ACOUSTIC CEILING HEIGTH 9` (EXISTING) OFFICE/WAIT AREAS CEILING HEIGHT 10' EXISTING — NO 'CHANGES BANQUET ROOM CEILING $EIGHT 10' -- EXISTING — NO CHANGE ADA RESTROOM HARD LID 5/8" GWB CEDING HEIGHT 10' ARE EXISTING, NO CHANGES NEW EMPLOYEE RESTROOM HARD LID 5/8" GWB CEILING HEIGHT 9' DINNING ROOM ACOUSTIC CEILINGS TO BE REMOVED REMAINS OPEN CEILING PAINTED WITH ' SEMI— GLOSS EXPOSED TO STRUCTURE — AT CEILING HEIGHT PAINTED GWB -'- NO CHANGE SIDE WALK NOTE Contractor to verify accurate existing wall. . sections and ceiling grid height at site .CIRCU - WALKWAY EMERGENCY EXIT W, PANIC HARDWARE s1I n Freezer Walls 9 %12` 18' T 414" 9' a -118` EXTERIOR LANDSCAPE AREA MAN • ENTRANCE EXITING DOUBLE GLASS DOORS ue.wcoppor tiro '[S�G PRIOR W 0 EXTERIOR Wfr4 .. EXISTING PLANTER 10'6X1O'6 5-m• 2+Y -O• ELC 118" •. METAL •S..:: a CEILING 4'-0" HIGH PONY WAIN MONARCH TRADING CORPORATION xavattrt WOW & DAM COViTT 37 a0010 DM St. {Va VOUIO . TOL 200:703-4161. f 3' Mi. 768 -5181; CECE ZEs MIRED' COMP. CONTRACT NO,1 • {' RTCOO tE.€ ?BITS DOCUMENT ;IBC ,„"Sails DESIGN CONCEPT, INFOR ATIC AND DATA PRIORITiETARY TO .6GI ARCN MONO CORP0RATl8N WHICH. ARE HOT ' €8 DISCLOSED OUTSIDE ••1 THE R :CLA d,. ORc^rANI7 TIOP3 NOR 1?'.PRo9Uc D WHOLE OR PART,. . I~XCEPT BY PRIOR WRITTEN CONTRACTUAL Aa' R ,' G MENTS wren MONARCH TRADING. CORK RATION. M.1 i:K (WET 1.700,.„SIO1< .Nix SODTRCEN" 1 R TUK IIA,W€A_„9ll6i3 s$4, . ALAI sHEETTITLE1 SHEETTITLE2 S SETT TLE3 20'4' 11' 9 -374" LARGE PENDANT LIGHT (L1) Dinning Teri fighting f . . 81'•' . existing roaiur (typ 2) OPEN CEILING - PAINTED WITH SEMI-GLOSS PAINT . DIRECTOR ARCHITECT REVIEWED COMPLIANC NFPA70 -NEC OCT 1 3 2010 r; CAP'S PROJECTNUMBER ROVED 5'-4" A OM HARD LID GWB CEILING EXIS G F 100 EA R ROt i 13'-4' I NEW Ft. LL HEIrW £..> CHECKED T. LMLY2 I O EMERGENCY EXIT W, PANIC HARDW EXTERIOR WALL 35`4 aS6g^ey� �P. p f�{. l�j�r] y� Revised Jul 2s, 28 70 119' -4" j MIZUKI JAPANESE BUFFET 1 7950 Southcenter. Parkway TukwiIa,.Wa. 98188. . REFLECTED CEILING SCALE: 3/161." :1` C RECEIV OCT 06 no PERMIT CENTER AUG 1