Loading...
HomeMy WebLinkAboutPermit EL10-0812 - WESTFIELD SOUTHCENTER MALL - BOBA SMOOTHIESBOBA SMOOTHIES 2800 SOUTHCENTER MALL K -1223 EL1O-0812 City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 9202470010 Address: 2800 SOUTHCENTER MALL TUKW Tenant Name: BOBA SMOOTHIES Permit Number: EL10 -0812 Issue Date: 10/29/2010 Permit Expires On: 04/27/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: FAISEL QURESHI Phone: 425 - 214 -1267 Address: 34114 35 AV SW , FEDERAL WAY WA 98023 Contractor: Name: SECANT ELECTRIC LLC Address: 7527 44 AV S , SEATTLE WA 98118 Contractor License No: SECANEL905D6 Phone: 206 370 -9925 Expiration Date: 04/01/2012 DESCRIPTION OF WORK: INSTALL ELECTRICAL FOR NEW KIOSK, REFRIGERATOR, ICE MAKER, ICE CREAM MAKER, FREEZER AND LIGHTS. Value of Electrical Work: NRES: $400.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $89.25 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ith whether specified herein or not. The granting of this permit does not pres construction • ; • erfo : ce of work. I am authorized to sign and obtain this electrical permit. e to give authority to violate or cancel the provisions of any other state or local laws regulating Signature: r Print Name: �nl2q/ �t7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0812 Printed: 10 -29 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwi la. wa. us Parcel No.: 9202470010 Address: Suite No: Tenant: PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW BOBA SMOOTHIES Permit Number: Status: Applied Date: Issue Date: EL10 -0812 ISSUED 10/12/2010 10/29/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 0/29/ 20 /(� doc: Cond -Elec ELI 0-0812 Printed: 10 -29 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us Electrical Permit No. 'L` 0— iz Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ,,�/ �// /,� King Co Assessor's Tax No'.:/ 9� ,�-41 t�Q 10 Site Address: s!) �/� (e+ti- f i!� (t 7- Suite Number: Ala 3 Floor: Tenant Name: P6 4'1 SM6at/it -eel New Tenant: ....Yes ❑ ..No w/ ' (1 Property Owners Name: Mailing Address: Zip City State CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: fr $A / Mailing Address: 3(// c( 3 5-17/ 4 vc s� Day Telephone: yg_s',-2,4- /0U ,�t�ry State Zip fMamber' E -Mail Address: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 7Q� Scope of Work (please provide detailed information): 46c_ 4/A.5.r ,,eC�7 ,� os /< /e e Will service be altered? ❑ Yes 03 No Type of Use: /69.6 S 4 Type of work: 1p, New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: cg Puget Sound Energy ❑ Seattle City Light H:Wpplications\Forms- Applications On Line \2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 Adding more than 50 amps? ❑ Yes ❑ No ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added /altered without service change $54.60 (up to 5 circuits) ❑ Circuits added /altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured /mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: I V5d•L (2r, / ( "L S �tr Mailing Address: ' 1 Date Application Accepted: l Date: I o/I (/t Day Telephone: �S —cat — 06 7 eft City State 0 Zip i) -t0 Date Application Expires: LA ) 11 Staff Initials: HAApplications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 0 C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0812 Address: 2800 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 10/12/2010 Applicant: BOBA SMOOTHIES Issue Date: Receipt No.: R10 -02052 Initials: User ID: Payee: WER 1655 Payment Amount: $89.25 Payment Date: 10/12/2010 02:25 PM Balance: $0.00 FAISEL QURESHI TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 056608 ACCOUNT ITEM LIST: Description 89.25 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 71.40 000.345.832.00.00 17.85 Total: $89.25 doc: Receiot -06 Printed: 10 -12 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION eoii 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -36 Project: 6 a6131- 51 0 Type of Inspection: Address: .�.,0o p Date Called: Special Instructions: . Date Wanted: j I ! ®(O a p.m. Requester: tt Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: COR,k-tir-toNi, ro<c)e Inspector: pi n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 01 106// INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �— 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 ( (1) 206) 431 -3670 Project: IV* C 00Pie5 Type of Inspection: �f/ 00 � Address: �� A �d Date Called: Special Instructions: Date Wanted: �°'" i�o� 6/11. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /2,0 4o15i (c tAD 7-0 he gf yo 8E (rC' eeR. 7.40.'8 Inspector: Date: a( REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit OW, PERMIT PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project: CS gO`Mtli Type of Inspection: 7 ®64 Address: 7X°C; M Date Called: Special Instructions: Date Wanted: I �� a,rn! Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: flA-Q1,1i) Inspector: gm/ Date: I 1014 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee :must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • n 4 N..�, PEW t; R . ,� v sL COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0812 DATE: 10 -12 -10 PROJECT NAME: BOBA SMOOTHIES SITE ADDRESS: 2800 SOUTHCENTER MALL - K -1223 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: , t �/�I �k) Building Division Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator n u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 1 0-14 -10 Complete 4 Incomplete ❑ Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 11 -11 -10 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SECANT ELECTRIC LLC UBI No. 2063709925 Status 7527 44Th Ave 5 License No. License Type Seattle Effective Date WA Expiration Date 98118 Suspend Date King Specialty 1 Limited Liability Company Specialty 2 602990237 Active SECANEL905D6 Electrical Contractor 4/1/2010 4/1/2012 General Unused Electrical Administrator INFORMATION License PHAN`TN9130D Name PHAN, TAM N Status Active Business Owner Information Name Role Effective Date Expiration Date PHAN, TAM N Partner /Member 03/22/2010 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SI5327 04/01/2010 Until Cancelled $4,000.00 03/22/2010 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip /Print.aspx 10/29/2010 GENERAL NOTES: PLUMBING a. 4" sanitary sewer line within tenantOs premises, under slab. b. 2" vent piping located within tenantUs pr 1 ' nder slab. estic water line with a ball valve thin tenantUs under slab. ELECTRICAL a. 200 amp, 208/120v single phase b.Electrical conduit from landlord's electrical panel to within tenant's premises, sized for the service provided. c. Electrical conductors from landlord's electrical panel to within tenant's premises, sized for the service provided. d. Provide a sub -meter that can be read at gement office. elephone conduit from lanlord's to ephone panel to within tenant's premises w/ (2) pair lines. SEPARATE PERMIT REQUIRED FOR: Meddanical Electrical t r Plumbing I Gas Piping CIty of Tukwila BUILDING DIVISION EQUIPMENT SCHEDULE ITEM QTY EQUIPMENT MAKE MODEL A 1 ICE MAKER U/C Ice -O -Matic Model No. ICEU150HA B 1 3 COMP. SINK Krowne Metal Model No. 18 -63C C 1 HAND SINK U/C N/A N/A D 1 ICE BIN U/C Krowne Metal Model No. 18 -36 E 3 BLENDER, BAR TYPE Vita -Mix Model No. 5004 H 1 FREEZER U/C Turbo Air Model No. MUF-60 I 1 FRIDGE U/C Turbo Air Model No. MUR -72 J 1 GELATO FRIDGE Turbo Air N/A K 1 MOP SINK N/A N/A L 1 WASH SINK N/A N/A ELECTRICAL KEY Phone/ Network port -Up down lights Furnished & Insfa6 by Landlord. #20 - 220volt Dedicated Circuit FP •1lOvolt Circuit •120v Circuit -Brass Floor Plug • FILE: FILE LOCATION: DC-DESIGNS •1 LEFT ISOMETRIC VIEW SCALE: NTS PAINT, TILE AND GRAPHICS PENDING LANDLORD APPROVAL F 17'-6' ED FOR COMPLIANCE WITH NFPA70 -NEC OCT 2 8 2010 Arlan rw _ l ut� • W.- nmetlfridesesiou i11 �I' i ONT ELEVATION SCALE: 1/4" = 1' -0" FILE COPY No. tkAtO 'VIA/— ii1 \/ review approval Is to and omissions. of construction do umerflW' s does not authorize violation of any code or ordnance. Receipt and I!4, .'. �is8�ed: BY 1.0A 'v/20/0 City Of BUILDING DIVISION • MEW FLOOR PLAN "m" SCALE: 1/4' = 1' -0" Wood Wall w/ Aluminum Strip By Landlord L_ WWI By Landlord Provide Smooth Paint & Graphic By Tenant Up Dowo lights by landlord Wall by Landlord Sign & Blade -Sign by Bamboo Flush by Tenant Tenant (2) RECESS 54" LCD MONITORS NEMO TILE, Tik Appiani Overhead & Side WWI By use a light color grout (bark counter wall) Landlord. Fish by Tenant- (srent.0rro wi •eromonreruvr Frameless Sneeze Guard WM1ita formica Counter -top I:I:I:LI:I rTTTTTTITTTTTTT" White formica Bamboo Flash Stainless Steel Kicker 10' -0' SECTION SCALE: 1/4" = 1' -0" LIGHTING PLAN SCALE: 1/4' = 1' -0" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. tUo 0B12 RECEIVED OCT 12 2010 PERMIT CENTER Westfield Working Drawing Review ReApproved as Nabs CI Raaubn4 Tease eftelebb Paw Y.. reviewed far ...web emir • efty. beloS11107 MVP. OM s m ro .m mwdv�nmId 'Debase.nbe+m. • 11maram Wee. moped n anawrb nano. be by tai w M am7 . Drowing electronically produced by "Douglas Crowell Design Inc." for internal use only. REVISIONS: Smoothie co -.Q mO South Center Mall SCALE: 1/4"=1' DATE: 05/21/10 DRAWN BY: D.0 CHECKED BY: D.0 PROJECT NO C06 -1 DCD DOUGLAS CROWEL DESIGN INC. 12514 63TH AVE E PUYALLUP, WA 98373 TEL: 845 -9382 EMAIL: T6circusOyohoo.com: SCALE: NTS *PO WER/DATA STUB OUTS @ FLOOR flOv CASH REGISTER 17' -6" 36" Counter CASH REGISTER r/1IIN I, 1 ILC /AIN1J urvArnlL.) r CAN LJIINU LfiIV VLL) ENTRY if 5 NOTE: Install bamboo finsh inside of counter. NOTE: Install latexrubber waterproofing material under the floor finish within the floating retail shop. Store Sign 220v l I1 U /C /c FREEZER REVIEWED FOR —� COMPLIANCE M FPA70,N WITH OCT 28 2010 ��k BUILDING f Tukwila DIVISION FLOOR DRAM. 3 COMP. S ( MOP • SINK 0 0 iLE1RECESS CUPS DISP/ FRIDGE BIN Irottx R 1j,�a' C'T�LV ♦ 220v v 1 I FLOOR PLAN CITY MAY REQUIRE UNDER COUNTER GREASE TRAP BY TENANT SCALE: 1/4" = (Plumbing) Tie-in to \Ljllandlord stub -in's 0a RECEIVED OCT 12 2010 PERMIT CENTER 0 0 0 Wood Wall w/ Aluminum Strip By Landlord Wall By Landlord Provide Smooth Paint & Graphic By Tenant. Up Down lights by Landlord Wall by Landlord Sign & Blade -Sign by Bamboo Finsh by Tenant. Tenant. COMPLIANCE /EDFOR LIANCE WITH NFPA70 -NEC OCT 282010 (2) RECESS 54" LCD MONITORS JB C�iY4 TukW11 ING DIVISION NEMO TILE, Tile Appiani UILD Overhead & Side Wall By use a light color grout (back counter wall)" Landlord. Fish by Tenant- (BREAKMETAL W/ AUTOMOTIVE PAINT ) Frameless Sneeze Guard White formica Counter -top White formica Bamboo Finsh Stainless Steel Kicker 10,-0" SECTION SCALE: 1/4" = 1' -0" L.. " .. ..._ii RECEIVED OCT 12 2010 PERMIT CENTER Directional Recess Light Store Sign M M PRE -WIRE FOR (2) RECESS LCD MONITORS REVIEWED FOH- COMPLIANCE WITH NFPA70 -NEC OCT 2 8 2010 City C' of Tukwila BUILDING DIVISION • • • • • • • • • • • • • •r LIGHTING PLAN SCALE: 1/4" = 1' -0" RECEIVED OCT 12 2010 PERMIT CENTER [SCA [DAT ITO-RA