Loading...
HomeMy WebLinkAboutPermit EL10-0818 - HIGHLINE MEDICAL CENTERHIGHLINE MEDICAL CENTER 12844 MILITARY RD S EL1O-0818 Parcel No.: Address: Tenant Name: Cityt Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1623049001 12844 MILITARY RD S TUKW HIGHLINE MEDICAL CENTER ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -0818 11/30/2010 05/29/2011 Owner: Name: HCH SPECIALTY CENTER Address: ATTN ACCOUNTING DEPT , 12844 MILITARY RD S 98168 Contact Person: Name: RICK ZEHNER Address: 5005 3 AV S , SEATTLE WA 98134 Contractor: Name: MCKINSTRY ELECTRIC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINE *982KG Phone: 206 - 832 -8012 Phone: 206 832 -8513 Expiration Date: 05/08/2012 DESCRIPTION OF WORK: REPLACEMENT OF MEDICAL IMAGING SCANNER Value of Electrical Work: NRES: $15,000.00 Fees Collected: RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied ami 'th, $438.13 National Electrical Code Edition: 2008 Ot\A- Date: t11 9201,19 ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature:: Print Name: j� 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0818 Printed: 11 -30 -2010 • a PERMIT CONDITIONS Permit No. EL10 -0818 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0 -081 8 Printed: 11 -30 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us • lElectrical Permit No. —�-1 r b Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION /1 ( King Co Assessor's Tax No.: \ \Q " qOO ( Site Address: (Z8YY itti /cry goad Gov Suite Number: Floor: Tenant Name: 4J.t4._ /i%./ Gco & 1/e Property Owners Name: ",/..-4/,‘e `lede v( p e&' /ee Mailing Address: 7(0 2s- ( :5/kes f& i s1 sZre c New Tenant: ❑ Yes (,ff..No —gviueti City bil7f State 98/6 Zip CONTACT PERSON - Who do we contact when your permit is'ready to be issued Name: FAc f< 2 z Mailing Address: -sus 3'2' Ave- 5 E -Mail Address: gcc4. - coin Day Telephone: 2Z6 g3z - Se(; l 9,73y City State Zip Fax Number: Z-0G - ' 3Z - ?Coto 9 'ELECTRICAL/CONTRACTOR INFORMATION Company Name: life-k v ?* -V Mailing Address: 5005 3F'' Ave_ $ Contact Person: ,2(C-4 E -Mail Address: RGA. Q�.,01-2 - fco/ $fyw Contractor Registration Number: /i%A/N E *95'2/ C7 Expiration Date: City State Zip Day Telephone: 2ao - a'.Z _ Of Z Fax Number: 2-e6- Cf 3 Z - 57-511/ Valuation of Project (contractor's bid price): $ POa Scope of Work (please provide detailed information): Will service be altered? ❑ /Yes I►∎ No i Type of Use: kte Awl p ct /nom} 5ecfxu-ve.A Type of work: v O ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy XSeattle City Light Adding more than 50 amps? ❑ Yes pr No ❑ Service Change ❑ Fire Alarm H:\Applications\Forms- Applications On Line\2010 Applications \7.2010 - Electrical Permit Application.doc bh Page 1 of 2 Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION 'NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature.cif Date: /0/ 2-40 Print Name: -t4N Day Telephone: 9 - 832--&/D 3 S° 5 &2� `,/f 9fr31 City State Zip Mailing Address: 5—R05" 32 Ave_ Date Application Accepted: ()- 1 — 1 J) Date Application Expires: /N1_. J / / H:\Apphcanons\Forms- Apphcanons On Line\20I0 Apphcanons \7 -20I0 - Electncal Pennn Application.doc bh Page 2 of 2 Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 1623049001 Address: 12844 MILITARY RD S TUKW Suite No: Applicant: HIGHLINE MEDICAL CENTER RECEIPT Permit Number: EL10 -0818 Status: APPROVED Applied Date: 10/13/2010 Issue Date: Receipt No.: R10 -02391 Payment Amount: $350.50 Initials: JEM Payment Date: 11/30/2010 10:54 AM User ID: 1165 Balance: $0.00 Payee: MCKINSTRY CO. SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11197 350.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 350.50 Total: $350.50 doc: Receipt -06 Printed: 11 -30 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1623049001 Address: 12844 MILITARY RD S TUKW Suite No: Applicant: HIGHLINE MEDICAL CENTER RECEIPT Permit Number: EL10 -0818 Status: PENDING Applied Date: 10/13/2010 Issue Date: Receipt No.: R10 -02066 Initials: TLS User ID: 1670 Payment Amount: $87.63 Payment Date: 10/13/2010 03:35 PM Balance: $350.50 Payee: MCKINSTRY CO SERVICE ACCOUNT TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11133 87.63 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 87.63 Total: $87.63 doc: Receiot -06 Printed: 10 -13 -2010 { INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Yz 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project 144 4g I60 Type of Inspection: (490 Address: a, pIra Date Called: Special Instructions:' Date Wanted: (/0/ m p.m. Requester: J Phone No: O Approved per applicable codes. Corrections required prior to approval. 13 COMMENTS: DKOclio/41, Inspector: 66440\ Date: ©r 01 ! n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit SPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �. Etio_ ogM' Project: IM 4 14 t-tAie d'f-blem.., Type of Inspection: Address: Il'91 ri i Date Called: -o Special Instructions: Date Wanted: /0(0 a.m., Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. N COMMENTS: - 0111 rlAy ru5 F T6 GE lip Are Inspector: Date: 011o61IJ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSP CTION NO. INSPECTION RECORD Retain a copy with permit et0-07r'e PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project:th 10144 tiEDI CAI"' Type of Inspection: Address: / j Date Called: Special Instructions: Date Wanted: • /3 �.rp� cm. Requester: !A/ Phone No: ElApproved per applicable codes. ❑ Corrections required prior to approval. <. COMMENTS: - CrnPLML 61/5 1> PPIT4C. .60 o -rn &lc AWL P. O 1( O '. -hpl 1 4 Al -' 1 Inspector: 664J6g, Date: 0103// REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION L 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: . G� WA" iC of Inspection: 70®5 Address: I24yt-i 11t..1r*� Date Called: Special Instructions: Date Wanted: aC.rry1 /%17 p.m. Requester: JJ Phone No: Approved per applicable codes. Corrections required prior to approval. 2 COMMENTS: - eoul Inspector: Date: (2171 1/0 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6A0-CE PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 4414L➢AJE 06) �r� VC/ Type of Inspection: ��� Address: iii7I-N rborilizi Called: Special Instructions: Date Wanted: � p �/ a.m. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspector: .--/ZfA4et n REINSPECTIOI I FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ILA /j,0 f 10 2006 Wa • 'gton State Nonresidential Energy Code Comp ce Form Interior Lighting Sum. -oary LTG -I NT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Highline Specialty Campus - CT Replacement Date 9/23/2010 12844 Military Road S, Tukwila WA For Building Department Use ._.- E Copy CT SCAN 164 Applicant Name: Hargis Engineers, Inc - Doug Foralund Applicant Address: 600 Stewart Street, Suite 1000, Seattle, WA 98101 Applicant Phone: 206- 448 -3376 Project Description ❑ Plans Included requirements. 4 New Building ❑ Addition -' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive Q Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area CT SCAN 164 CT Scan Room (Excempt NREC 1512.1 -1) REVIEWED COMPLIANCE NFPA70 .FOR -NEC WITH ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed REVIEWED COMPLIANCE NFPA70 .FOR -NEC WITH OCT 2 8 ?m( City offaira UILDING DIVISION Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. r RECEIVED„ CITY OF TD OCT 132010 PERMIT CENTER tUO -bbl $ 14.4 COPY • PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: EL10 -0818 DATE: 10/13/10 PROJECT NAME: HIGHLINE MEDICAL CENTER SITE ADDRESS: 12844 MILITARY RD S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS. B I ding Ivlslon ion Public Works Fire Prevention nStructural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 10/14/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Building Please Route Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/11/10 Approved Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name MCKINSTRY ELECTRIC UBI No. 602198837 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINE'982KG Suite /Apt. License Type Electrical Contractor City Seattle Effective Date 5/7/2002 State WA Expiration Date 5/8/2012 Zip 98124 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company FACILITY ELECTRICAL SRVCS LLC Master Electrician INFORMATION License ZEHNER'962CJ Name ZEHNER, RICK A Status Active Business Owner Information Name Role Effective Date Expiration Date BLACK, STEPHEN Partner /Member 05/07/2002 Bond Amount ALLEN, DEAN C Partner /Member 05/07/2002 929495258 MOORE, DOUGLAS J. Partner /Member 05/07/2002 ELECTRICAL CITATION TEPLICKY, J. WILLIAM Partner /Member 05/07/2002 TRAVELERS CAS a SURETY CO formation Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY CO 929495258 05/04/2010 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 04/05/2010 1 TRAVELERS CAS a SURETY CO 103737415 04/29/2002 Until Cancelled 05/04/2010 $4,000.00 05/07/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ESWAT00252 5/11/2009 19.28.010 RCW ELECTRICAL CITATION Satisfied $250.00 ESWAT00251 5/11/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $150.00 https://fortress.wa.gov/lni/bbip/Print.aspx 11/30/2010 CT EQUIPMENT REPLACE HIGHLINE SPECIALTY CAMPUS TUKWILA, WASHINGTON OWNER CONTACT: DIANNE MUNROE ARCHITECT CONTACT: STEVEN WESCOTT, AIA STRUCTURAL CONTACT: JOHN SMITH, P.E., S.E. MECHANICAL CONTACT: JARED ROBILLARD ELECTRICAL CONTACT: DOUG FORSLUND PROJECT INFORMATION PROJECT DESCRIPTION: JOB SITE ADDRESS: TAX PARCEL NUMBER: ZONING CLASSIFICATION: PERMITTING AUTHORITY: ARCHITECTURAL SYMBOLS HIGHLINE MEDICAL CENTER 16251 SYLVESTER ROAD SW„ BURIEN, WA 98166 NACIARCHITECTURE 2201 SIXTH AVENUE, SUITE 1405, SEATTLE, WA 98121 (206) 441 -4522 COLLONS & SMITH STRUCTURAL ENGINEERS 485 FRONT STREET NORTH, SUITE F -3, ISSAQUAH, WA 98027 (425) 369-1101 HARGIS 600 STEWART STREET, SUITE 1000, SEATTLE, WA 98101 (206) 448 -3376 HARGIS 600 STEWART STREET, SUITE 1000, SEATTLE, WA 98101 (206) 448 -3376 INTERIOR REMODELING TO THE FiRST FLOOR OF THE WEST WING FOR DIAGNOSTIC IMAGING EQUIPMENT REPLACEMENT. APPLICATION FOR ALTERATIONS TO MECHANICAL, ELECTRICAL AND FIRE PROTECTION SYSTEMS WILL BE UNDER SEPARATE PERMIT. 12844 MILITARY ROAD SOUTH TUKWILA, WASHINGTON 98168 162-304-9001 0 - OFFICE CITY OF TUKWILA DEPARTMENT OF HEALTH Ai 1498 R149B ROOM NAME 101 JA GRID LINE DOOR IDENTIFICATION RELITE IDENTIFICATION REVISION MATCH LINE Shaded area is side considered WORK POINT, DATUM POINT, CONTROL POINT DETAIL Upper mark denotes drawing number Lower mark denotes sheet PARTIAL BUILDING SECTION. INTERIOR ELEVATION Elevation number denoted in arrow Sheet . number denoted in box ROOM IDENTIFICATION CODED NOTE WALL TYPE DASHED LINE Used to denote items hidden, overhead, not in contract (NIC), or to be removed BREAK LINE Material to continue CENTER LINE, GRID LINE PROPERTY LINE LEGAL DESCRIPTION IN THE COUNTY OF KING, STATE OF WASHINGTON: SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION THAT PORTION OF THE NORTH ONE -HALF OF THE NORTH NORTHEAST ONE- QUARTER OF SECTION 16, TWP, 23N, RANGE 4E, W.M., iN KING COUNTY, WASHINGTON, LYING EASTERLY OF MIUTARY ROAD, EXCEPT THAT PORTION OF THE NORTHEAST ONE- QUARTER OF THE NORTHEAST ONE- QUARTER OF SECTION 16, TWP, 23N RANGE 4E, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: 1. BEGINNING AT A POINT ON THE SOUTH LINE OF THE NORTHEAST 1/4 OF THE NORTHEAST 1/4 OF SAID SECTION 16, DISTANT EAST 561 FEET FROM THE SOUTHWEST CORNER THEREOF; THENCE NORTH, AT RIGHT ANGLES 184 FEET, THENCE WEST ON A LINE PARALLEL WITH SOUTH LINE OF SAID SUBDIVISION 225 FEET; THENCE NORTH AT RIGHT ANGLES 210 FEET; THENCE WEST ON A LINE PARALLEL WITH SOUTH LINE OF SAID SUBDIVISION TO THE EASTERLY LINE OF MILITARY ROAD; THENCE SOUTHERLY ALONG SAID EASTERLY LINE OF MILITARY ROAD TO AND INTERSECTING WITH THE SOUTH LINE OF SAID SUBDIVISION TO POINT OF BEGINNING. AND EXCEPT THAT PORTION OF THE NORTHEAST 1/4 OF THE NORTHEAST 1/4 OF SECTION 16, TWP, 23N, RANGE 4E, W.M., IN KING COUNTY, WASHINGTON, DESCRIBED AS FOLLOWS: 2. BEGINNING AT THE INTERSECTION OF THE SOUTH LiNE OF THE NORTH 160 FEET OF SAID SUBDIVISION WITH THE EASTERLY MARGIN OF MILITARY ROAD; THENCE EASTERLY ALONG SAID SOUTH LINE 200 FEET; THENCE NORTHERLY AT RIGHT ANGLES 160 FEET TO THE NORTH LINE OF SAID SUBDIVISION; THENCE WESTERLY ALONG SAID NORTH LINE TO THE EASTERLY LINE OF SAID MILITARY ROAD; THENCE SOUTHERLY ALONG SAID EASTERLY LINE TO THE POINT OF BEGINNING; ' EXCEPT THAT PORTION IF ANY, CONVEYED TO KING COUNTY FOR 128TH STREET, BY DEED RECORDED UNDER AUDITOR'S FILE NO.5274608. ARCHITECTURAL MATERIALS DETAIL INDICATIONS ACOUSTIC TILE OR BOARD ROOFING BRICK CAULKING OR SEALANT CERAMIC TILE CONCRETE PRECAST CONCRETE ::?stairts 11I NlrilflAlt MITHitltiN419111tiTft UAI V,/ /71 ii- /7/ ii rlillLlf� PLAN INDICATIONS CONCRETE MASONRY UNIT EARTH/FINISH GRADE GLASS GRAVEL GYPSUM BOARD INSULATION, BATT INSULATION, RIGID METAL MORTAR, PLASTER, SAND PLYWOOD WOOD, FINISH WOOD FRAMING Continuous member WOOD FRAMING Interrupted member EXISTING WALL NEW STUD WALL NEW CONCRETE MASONRY UNIT NEW CONCRETE NEW BRICK ROOM ARCHITECTURAL ABBREVIATIONS VICINITY MAP TRUE ' NO SCALE NORTH REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan subirtittel and may include additional plan review fees. 164 HIGHLiNE SPECIALTY CAMPUS PROJECT LOCATION. West Wing, 1st Floor Tenant Improvement PLAN NORTH • T A/C ACOUS AD ADJ ADJT AFF AL ALT ANC APPROX ARCH AUTO BD BET BITUM BLDG BLK BLKG BM BOTT BRG BUR CAB CB CER CG CJ CLG CLKG CLO CLG CLR CMU COL CONC CONST CONT CORR CPT CT CTR DBL DEMO DF DIA DIAG DIM DP DR DN and angle at centerline channel diameter or round plate pound or number tee air conditioning acoustical area drain adjustable adjacent above- finished floor aluminum alternate anchor(age) approximate architectural automatic board between bituminous building block blocking beam bottom bearing built up roof cabinet catch basin, ceramic corner guard control joint ceiling calking closet ceiling clear concrete masonry unit column concrete construction continuous corridor carpet ceramic tile center double demolish, demolition drinking' fountain diameter diagonal dimension dampproof(ing) door down EA EJ EL ELEC ELEV EQ EQUIP EW EWC EXH EXIST EXP EXT FA FAB FD FE FEC FEC -S FF FFL FIN FL FLG FLUOR FOC FOF FOM FOS FOSH FP FT GA GALV GL GLZ GMU GYP BD HC HD HDWD HORIZ HT HVAC ID INCL INFO INSUL INT L LAB LAM LKR LT LV JT each expansion joint elevation electrical elevator equal equipment eyewash electric water cooler exhaust existing expansion exterior fire alarm fabricate floor drain fire extinguisher fire extinguisher cabinet (recessed) fire extinguisher cabinet (semi - recessed) factory finish finished floor line finish floor flooring fluorescent face of concrete face of finish face of masonry face of studs face of sheathing fireproof foot, feet gouge galvanized glass glazing glazed masonry unit gypsum board handicap (accessible) head hardwood horizontal height heating/ventilating/air- conditioning inside diameter (dim.) include information insulation interior length, long laboratory laminate locker Tight, left louver joint MACH MATL MAX MC MECH MEZZ MFR. MIN MIR MISC MO MT(D) MTL MUL N NIC NO OR # NOM NTS OA OC OD OFCI OFOI OH OHD OPNG OPP ORIG PC PERF PERP PLAM PL PLAS PLYWD PNL PR PREFAB PREFIN PROD' PT PTD PTDR PTN PTR R RCP REBAR RECD REF RF REFR RO RM REQD machine material maximum medicine cabinet mechanical mezzanine manufacturer minimum . mirror miscellaneous masonry opening mounted) metal mullion north not in contract number nominal not to scale over -all . on center outside diameter (dim.) other furnished contractor installed other furnished owner installed overhead door opening opposite original pre -cast perforated perpendicular plastic laminate plate plaster plywood panel pair prefabricate(d) prefinish(ed) project point, paint paper towel dispenser combination paper towel dispenser & receptacle partition paper towel receptacle riser, radius reflected ceiling plan reinforcing bar received reference roof refrigerator rough opening room required S south SCD seat cover dispenser SD soap dispenser SECT section SHR shower SHT sheet SHTG sheeting SIM similar SND sanitary napkin dispenser SNR sanitary napkin receptacle SPEC specification SQ square SSK service sink SS stainless steel STD standard STL steel STOR storage STRUCT structural SYS system TB towel bar, tackboard TC top of curb TEL telephone TEMP temporary TF top of footing THK thick THRU through TM top of masonry TP top of pavement TPD toilet paper dispenser TS tube steel TV television TVB television bracket TW top of wall TYP typical UNFIN unfinished UNO unless noted otherwise UR urinal VB vapor barrier VCT vinyl composition tile VER verify VERT vertical VEST vestibule VOL volume W west, wide, width W/ with WB whiteboard WC water closet WD wood WDW window W/O without WP waterproof WSCT wainscot WS weather stripping WT weight WTR water FILE COPY Pau* tio..11221112... Plan review apprro d is subject to wore and i Approval of constmc ion documents ages not authorize the violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Isacknowledged: By City Of Ibliwila BUILDING DIVISION ■ EXTERIOR MA RIAL STORAGE ARE MATERIAL DELI\ AT FIRST FLOOR LOCATION MAP ■ REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC OCT 2 8 2010 City o ' kwila BUILDING IVISION NO SCALE INDEX OF DRAWINGS GENERAL G0.1 PROJECT COVER SHEET G11 FIRST FLOOR LIFE /SAFETY PLAN ARCHITECTURAL A2.1 FIRST FLOOR DEMOLITION PLAN A3.1 FIRST FLOOR PLAN, WALL TYPES, SCHEDULES A3.2 ROOF PLAN & EXTERIOR DETAILS A5.1 PARTIAL STRUCTURAL ROOF PLAN & STRUCTURA ' ETAILS A5.2 PARTIAL BUILDING SECTIONS & INTERIOR DETA A7.1 INTERIOR ELEVATIONS, CASEWORK & INTERI • DETAILS A9.1 FIRST FLOOR REFLECTED CEILING PLAN & ILING DETAILS MECHANICAL MO.1 MO.2 MO.3 MO.4 MO.5 MO.6 MO.7 M1.1 M1.2 M1.3 M2.0 M2.1 M3.1 M5. .1 M9.1 tic*** :lot* MECHANICAL LEGEND GENERAL NOTES AND ABBREVI k ONS MECHANICAL SPECIFICATION MECHANICAL SPECIFICATis 'S MECHANICAL SPECIFIC ONS MECHANICAL SPECIF ATIONS MECHANICAL EQU- ENT SCHEDULES BASEMENT PL ® ING DEMOLITION- PLAN FIRST FLOG' LUMBING DEMOLITION PLAN FIRST FL ' • R HVAC DEMOLITION PLAN BASE'S - NT PLUMBING PLAN FI ` = FLOOR PLUMBING PLAN RST FLOOR HVAC PLAN FiRST FLOOR FIRE SUPPRESSION PLAN MECHANICAL ROOF PLAN MECHANICAL DETAILS ELECTRICAL E0.1 ELECTRICAL LEGEND E0.2 ELECTRICAL SPECIFICATIONS ED1.1 ELECTRICAL DEMOLITION PLAN E2.1 PARTIAL FIRST FLOOR LIGHTING PLAN E3.1 PARTIAL FIRST FLOOR POWER & SYSTEMS PLAN E3.2 PARTIAL ROOF POWER PLAN E9.1 ELECTRICAL ONE -LINE DIAGRAM AMU+ OF TC LA OCT 13 2010 PERMIT CENTER 1/‘°1944A1) a PROJECT COVER SHEET REVISIONS ARDINE SHINGTON z CO 0 0 ce z LIJ W U -J 0- W z W 0 U W U 0 LL N 0 N a 3 0 cn NAC NO FILE DRAWN CHECKED DATE 121 -10017 G0.1 KRL SRW 9 -10 -2010 G 0.1 r -- I I 1 • •1 • x1l 11 11 II II II I I NON iv a NMI MC NI1N INN _u INN ' 11N - -• ON NO IN ■M NM NON NM NNE Nil UNE INN MIN NNE • N INN 111 IRO •ui INN INN ■ SCI L xl — L ■ 0 RADIOLOGY ROOM �0 4111111.11 NI I 111 ■1 111::- INN ;■1 111:IN, 1 0 PAT iTLTg TECH SUPPORT • HALLWAY RADIOLOGY ROOM 121 I III I ■1 I ■I CORRIDOR AREA OF WORK *11•111 ol em IN 111111 es 10 Nun ow ow 4, 111 U!C 111 11i Ni 11 111 ME NON CilI MN 111 UN • HALLWAY DIAGNOSTIC IMAGING RECEPTIOA PATIENT DRESSING WAITING 0 0 CORRIDOR Ass —:. 2 be ism vi- Hun, 1 iii psi I® � 1 1 1 1 1 1 1 1 CORRIDOR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RUC I■ WEST WING FIRST FLOOR LIFE /SAFETY PLAN ■II III Scale: 1/8" = 1 >, _ 0" + REVIEWED FOR COMPLIANCE WITH H NFPA70 N OCT 2 8 2010 City o Tukwila l� ISION CODE DATA CONSTRUCTION TYPE: OCCUPANCY TYPE: ALLOWABLE AREA: FIRE PROTECTION: GOVERNING CODES: NUMBER OF STORIES: FLOOR AREA: WEST WING — TYPE II —A (NO CHANGE) GROUP 1 -2: HOSPITAL (NO CHANGE) 90,000 SF FULLY SPRINKLERED PER 903.3.1.1 AND NFPA 13 (N0 CHANGE) FIRE ALARM SYSTEM (NO CHANGE) WASHINGTON STATE BUILDING CODE 2009 INTERNATIONAL BUILDING CODE (WAC AMENDMENTS) 2003 ICC /ANSI A117.1 (WAC AMENDMENTS) 2009 INTERNATIONAL MECHANICAL CODE (WAC AMENDMENTS) 2009 INTERNATIONAL FIRE CODE (WAG AMENDMENTS) 2009 UNIFORM PLUMBING CODE (WAC AMENDMENTS) 2008 NATIONAL ELECTRICAL CODE (WAC AMENDMENTS) WASHINGTON STATE NON — RESIDENTIAL ENERGY CODE CITY OF TUKWILA BUILDING AND ZONING CODES 3 (NO CHANGE) AREA OF TENANT IMPROVEMENT = 509 S.F. CODE PLAN GENERAL NOTES 1. SEE FLOOR PLANS FOR DIMENSIONS, WALL TYPE REFERENCES. 2. SEE ELECTRICAL FOR EXIT SIGNS AND EMERGENCY EGRESS LIGHT FIXTURES. 3. WEST WING IS TYPE II —A, FULLY SPRINKLED CONSTRUCTION. QUICK RESPONSE HEADS ARE USED WHERE ALLOWED BY IBC CHAPTER 9. 6. FIRESTOP ALL PENETRATIONS THROUGH FIRE —RATED WALL AND FLOOR /CEILING ASSEMBLIES. .SEAL PENETRATIONS TO RETAIN THE INTEGRITY OF THE TIME —RATED CONSTRUCTION 7. INTERIOR WALL AND CEILING FINISHES SHALL CONFORM TO IBC SECTION 803.1 AND TABLE 803.4 FOR FLAME SPREAD REQUIREMENTS. FIRE PROTECTION NOTES 1. SEE MECHANICAL DRAWINGS FOR FIRE SPRINKLER SYSTEM ALTERATIONS ASSOCIATED WITH TENANT IMPROVEMENT WORK IN ACCORDANCE WITH IBC 9011 AND NFPA 13, SPRINKLER DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER. 2. SEE ELECTRICAL DRAWINGS FOR BUILDING FIRE ALARM SYSTEM ALTERATIONS ASSOCIATED WITH TENANT IMPROVEMENT WORK PER NFPA 72, FIRE ALARM DRAWINGS TO BE SUBMITTED BY LICENSED INSTALLER. 3. FIRE EXTINGUISHERS TO BE PROVIDED ON A MAXIMUM TRAVEL DISTANCE OF 75' TO ANY EXTINGUISHER LOCATION. PLAN LEGEND - - M - - - rrt EXISTING FIRE PARTITION, 1 HOUR FIRE — RESISTIVE RATING PER IBC 708 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 II•I 1 EXISTING SMOKE BARRIER, 1 HOUR FIRE — RESISTIVE RATING PER INC 709 NEW FIRE BARRIER, 1 HOUR FIRE — RESISTIVE RATING PER IBC 708 ■ I I EXISTING FIRE BARRIER, 2 HOUR FIRE— RESISTIVE RATING PER IBC 706 1 OCCUPANCY 1 OCCUPANCY SUITE (THIS PROJECT) FIRESTOPPING: ALL PENETRATIONS MADE THROUGH FIRE —RATED WALLS, CEILINGS AND FLOOR ASSEMBLIES, BOTH EMPTY HOLES AND HOLES ACCOMMODATING SUCH ITEMS AS DUCTS, PIPES, CONDUIT, ETC. SHALL BE SEALED. PENETRATIONS SHALL BE SEALED TO RETAIN THE INTEGRITY OF THE TIME —RATED CONSTRUCTION BY MAINTAINING AN EFFECTIVE BARRIER AGAINST THE SPREAD OF FLAME, SMOKE, AND GASES, IN ACCORDANCE WITH THE REQUIREMENTS OF IBC SECTION 712 — FIRESTOPPING. MECHANICAL AND ELECTRICAL RELATED PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR MAKING THE PENETRATION — SEE MECHANICAL AND ELECTRICAL. Ekt...pto-oo 818 N CD KEY PLAN NOT TO SCALE CITY 4F TU (VV1LA UCT 13 2010 PERMIT. CENTER 4 PARTIAL FIRST FLOOR LIFE /SAFETY PLAN og REVISIONS • 5785 GISTERED EC JARDINE ASHINGTON to 0 0 z w w U 0 Nw L.L z cw 0 w 1— U V w tan owl TECTURE V cc NAC NO FILE DRAWN CHECKED DATE 121 - 10017 G1 -1 SRW SRW 9 -10 -2010 2201 SIXTH AVENUE! SUITE 1405 1 SEATTLE WA 96121 -1847 I P: 206.441.45221 F206.442.7917 GENERAL 1/ EXISTING ELECTRICAL TO BE REMOVED EXISTING ELECTRICAL TO REMAIN NEW ELECTRICAL WORK - - 1 - MATCHLINE OR PROPERTY LINE MO MIN - - ENLARGED PLAN BOUNDARY DETAIL /PLAN IDENTIFIER SECTION IDENTIFIER ELEVATION IDENTIFIER REVISION DEFINITION AREA, AREA ENCIRCLED CONTAINS CHANGES MADE SUBSEQUENT TO PREVIOUS ISSUE 0 REVISION CALLOUT FLAG NOTE TAG O DEMOLITION NOTE TAG 0 EQUIPMENT TAG MECHANICAL EQUIPMENT TAG MECHANICAL EQUIPMENT TAG AHU -o1 NORTH ARROW OLOCATION WHERE PICTURE WAS TAKEN AND DIRECTION UGHTING A 0 DEVICE SUBSCRIPTS 12ab L(UGHT FIXTURE TYPE) " - (CIRCUIT NUMBER /SWITCHLEG) 0 I-0-1 FLUORESCENT LIGHTING FIXTURE (SIZES VARY, REFER TO FIXTURE TYPE) EMERGENCY FLUORESCENT LIGHTING FIXTURE (SIZES VARY, REFER TO FIXTURE TYPE) FLUORESCENT STRIP LIGHTING FIXTURE (SIZES VARY, REFER TO FIXTURE TYPE) EMERGENCY FLUORESCENT STRIP LIGHTING 1-4—I FIXTURE (SIZES VARY, REFER TO FIXTURE TYPE) 00 • • a �❑ UNDERCABINET FLUORESCENT LIGHTING FIXTURE HID, FLUORESCENT OR INCANDESCENT LIGHTING FIXTURE EMERGENCY HID, FLUORESCENT OR INCANDESCENT LIGHTING FIXTURE WALL MOUNTED HID, FLUORESCENT OR INCANDESCENT LIGHTING FIXTURE POLE MOUNTED LIGHTING FIXTURE, QUANTITY OF HEADS AS INDICATED. 04:00 DOUBLE HEAD, POLE MOUNTED, LIGHTING FIXTURE LIGHTING TRACK WITH FIXTURES SELF - CONTAINED BATTERY POWERED EMERGENCY LIGHTING FIXTURE EXIT SIGN, UNIVERSAL MOUNTING (SHADED AREA INDICATES DIRECTION ARROWS) HEXIT SIGN, WALL MOUNTED (SHADED AREA INDICATES DIRECTION ARROWS) OCCUPANCY SENSOR, CEILING MOUNTED ®X WHERE INDICATED, SUBSCRIPT INDICATES TYPE OCCUPANCY SENSOR, WALL MOUNTED SWITCHES s SWITCH, SPST UON OR AS DEFINED BY SUBSCRIPT a = SWITCH LEG T = TIMER 3 = THREE WAY MC = MOMENTARY CONTACT 4 = FOUR WAY P = PILOT UGHT K = KEYED LV = LOW VOLTAGE D = DIMMER OS = OCCUPANCY SENSOR LVM = LOW VOLTAGE PROGRAMMABLE (a,b,c) OR (a -c) CAN BE USED TO DESIGNATE MULTIPLE SWITCHES. ANY COMBINATION OF SWITCH TYPES CAN BE USED. (Le. 3K = 3 WAY KEYED SWITCH) POWER SWITCH BOARD /SWITCHGEAR PANELBOARD, FLUSH MOUNTED PANELBOARD, SURFACE MOUNTED (FRONT) TRANSFORMER 0 MOTOR CONNECTION. 0+ DISCONNECT SWITCH, NON FUSED 12, DISCONNECT SWITCH, FUSED ❑e + ENCLOSED CIRCUIT BREAKER VFD VARIABLE FREQUENCY DRIVE MANUAL MOTOR STARTER WITH THERMAL OVERLOADS COMBINATION STARTER /DISCONNECT ® MAGNETIC STARTER EQUIPMENT CONNECTION. CONFIRM CONNECTION WITH EQUIPMENT MANUFACTURER QF /S FIRE /SMOKE DAMPER 0 PUSHBUTTON CONTROLLER (SINGLE OR MULTIPLE BUTTONS) N EMERGENCY POWER OFF PUSHBUTTON RECEPTACLES GFCI `` DEVICE SUBSCRIPTS (GFCI,WP,IG OR OTHER SUBSCRIPT) +42" 12-.4` (CIRCUff NUMBER) (NON- STANDARD MOUNTING HEIGHT) - 0 SPECIAL RECEPTACLE DUPLEX RECEPTACLE FOURPLEX RECEPTACLE DUPLEX RECEPTACLE, ABOVE COUNTER (MOUNTED 4" TO CENTERUNE ABOVE BACKSPLASH) Sc FOURPLEX RECEPTACLE, ABOVE COUNTER (MOUNTED 4" TO CENTERUNE ABOVE BACKSPLASH.) ec SPLIT WIRED DUPLEX RECEPTACLE DROP CORD RECEPTACLE RACEWAYS AND BOXES 0 JUNCTION BOX F PB xx 0 xx ®A OA m POWER POLE, FLOOR TO CEILING FURNITURE WALL FEED OUTLET BOX PULL BOX (WHERE INDICATED, SUBCRIPT INDICATES PULL BOX NUMBER) MANHOLE (WHERE INDICATED, SUBCRIPT INDICATES MANHOLE NUMBER) HANDHOLE FLOORBOX (SUBSCRIPT INDICATES TYPE, WHERE SUBSCRIPT, SEE SPECIFICATIONS) POKETHRU (SUBSCRIPT INDICATES TYPE, WHERE NO SUBSCRIPT, SEE SPECIFICATIONS) ONE UNE DIAGRAM - - - - EQUIPMENT ENCLOSURE BUS WIRE —a— TERMINAL / LUG CONNECTION A DELTA i WYE E CURRENT TRANSFORMER I � I - - TRANSFER SWITCH n CIRCUIT BREAKER, FIXED �- DISCONNECT SWITCH FUSED SWITCH FUSE Cyl CIRCUIT BREAKER WITH I PROTECTION ST < CIRCUIT BREAKER WITH GROUND FAULT SHUNT TRIP OPERATOR FUSED SWITCH WITH GROUND FAULT PROTECTION /O/ MOTOR CONNECTION GENERATOR OM METER ST SHUNT TRIP EPM ELECTRONIC POWER METER 1 SPD 1- SURGE PROTECTIVE DEVICE -�- GROUND AVAILABLE FAULT CURRENT (SYMMETRICAL) TAG 12,241 FEEDER TAG TRANSFORMER x_ 20 i2ov 8Y 1 z PANELBOARD - MAIN LUGS ONLY PANELBOARD - MAIN CIRCUIT BREAKER NO TELECOMMUNICATIONS SYSTEM SYSTEM SURFACE METAL RACEWAY RACEWAY CONCEALED IN WALL OR IN CEILING (EXPOSED IN UNFINISHED AREAS) RACEWAY RUN BELOW FLOOR OR BELOW GRADE ^^- FLEXIBLE RACEWAY RACEWAY INSTALLED VERTICALLY OR TURNING UP ) RACEWAY TURNING DOWN RACEWAY CONTINUATION ] RACEWAY STUB WITH BUSHING [—] RACEWAY SLEEVE WITH BUSHINGS EZ -PATH FIRE STOPPING SLEEVE CABLE TRAY, 12"W x 4 "H OVERHEAD, UNLESS OTHERWISE NOTED mT CABLE TRAY, OVERHEAD LADDER TYPE HOMERUN TO PANEL HA-3 (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) 1 B-'-(GAUGE OF WIRE OTHER THAN AWG #12) -1111 NUMBER OF CONDUCTORS (GROUND CONDUCTOR) (PHASE CONDUCTORS) (NEUTRAL CONDUCTOR) FLUSH MOUNT /FURNITURE DEVICE (X = REPRESENTS THE # OF TELECOMMUNICATION JACKS.) (W = TELECOMMUNICATIONS WALL PHONE MTD AT +54" AFF.) (P = PAYPHONE, WALL MOUNTED AT +54" AFF.) (B = BLANK COVER PLATE.) (F = MODULAR FURNITURE DEVICE.) Y�(POS = POINT OF SALE.) (S = SURFACE MOUNT.) (WAP = WALL MOUNTED WIRELESS DATA DEVICE.) NURSE CALL SYSTEM NCMS NCTC NURSE CALL MASTER STATION NURSE CALL TERMINAL CABINET DOME LIGHT I-€ (WHERE INDICATED, R= RED(NURSE'S AID), W= WHITE(BED 1), RWGB G =GREEN(BED 2), B =BLUE(CODE BLUE)) DS ES PC CODE BLUE STATION DUTY STATION EMERGENCY STATION - PUSH FOR HELP NURSE CALL STATION PULL CORD STATION STAFF STATION NOT ALL SYMBOLS MAY APPEAR ON TI-E DRAWINGS ABBREVIATIONS GENERAL NOTES A AC AF AF AFF AG AHJ AIC AS AT ATS AWG BAS C CAN CB AMPERE AIR CONDITIONING; ALTERNATING CURRENT AMP FRAME AMP FUSE; AMP FRAME ABOVE FINISHED FLOOR ABOVE GRADE AUTHORITIES HAVING JURISDICTION AMPERE INTERRUPTING CURRENT AMP SWITCH AMP TRIP AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BUILDING AUTOMATION SYSTEM CONDUIT; DEGREES CELSIUS COMMUNITY ANTENNA TELEVISION CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CT CURRENT TRANSFORMER DDC DIRECT DIGITAL CONTROL (E) EF ELEV EM EMT EPM EPO FA FAAP FACP FSD G GFI GND HP HORSEPOWER EXISTING EXHAUST FAN ELEVATION EMERGENCY ELECTRICAL METALLIC TUBING ELECTRONIC POWER METER EMERGENCY POWER OFF 1. PERFORM WORK IN ACCORDANCE WITH APPLICABLE NATIONAL AND STATE CODES AS AMENDED LOCALLY AND ENFORCED BY THE AHJ. 2. OBTAIN AND PAY FOR PERMITS REQUIRED FOR INSTALLATION OF WORK. ARRANGE AND SCHEDULE REQUIRED INSPECTIONS. 3. DRAWINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE COMPONENTS AS REQUIRED FOR A COMPLETE OPERATIONAL SYSTEM WHETHER OR NOT SPECIFICALLY SHOWN ON THE DRAWINGS. 4. DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE DEVICE LOCATIONS AND ELEVATIONS WITH APPROPRIATE DOCUMENTS INCLUDING CASEWORK SHOP DRAWINGS AND ARCHITECT'S INTERIOR ELEVATIONS PRIOR TO ROUGH -IN. 5. COORDINATE ELECTRICAL WORK WITH THAT OF OTHER TRADES. REFER TO MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE DRAWINGS AND SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO FABRICATION, PURCHASE, AND INSTALLATION OF WORK. 6. COORDINATE LOCATION OF LIGHT FIXTURES AND CEILING MOUNTED DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS. 7. PROVIDE RATED ENCLOSURES AROUND ALL LIGHT FIXTURES PENETRATING RATED CEILINGS. COORDINATE WITH ARCHITECTURAL. 8. FUSE; DEGREES FAHRENHEIT FIRE ALARM _.- FIRE ALARM ANNUNCIATOR PA ELREVIEWED.FOR� FIRE ALARM CONTROL PANEL COMPLIANCE WITH FIRE SMOKE DAMPER NFPA70 - NEC GROUND OCT 2 8 2010 9. GROUND FAULT INTERRUPTER GROUND IDF IG J kVA kW KCMIL KVAR LCP M MCB MDF MH MLO MTS City of Tukwila BUILDING DIVIS INTERMEDIATE DISTRIBUTION FRAME ISOLATED GROUND JUNCTION KILOVOLT AMPERE KILOWATT THOUSAND CIRCULAR MILS KILOVOLT AMPERE REACTIVE LIGHTING CONTROL PANEL METER MAIN CIRCUIT BREAKER MAIN DISTRIBUTION FRAME MANHOLE MAIN LUGS ONLY MANUAL TRANSFER SWITCH N NEUTRAL NIC NOT IN CONTRACT NL NIGHT LIGHT OS OCCUPANCY SENSOR P PF PH PVC RCP REC REV RM SMR ST SWBD TP TV TVSS TYP UG UON UPS V VA VFD W W/ W/0 WP XFMR TRANSFORMER POLE POWER FACTOR PHASE POLYVINYL CHLORIDE REFLECTED CEILING PLAN RECEPTACLE REVISION ROOM SURFACE METAL RACEWAY SHUNT TRIP SWITCHBOARD TAMPER PROOF TELEVISION TRANSIENT VOLTAGE SURGE SUPPRESSION TYPICAL UNDERGROUND UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY VOLTS VOLT AMPERES VARIABLE FREQUENCY DRIVE WATT; WIRE WITH WITHOUT WEATHERPROOF Y WYE DEMOLISH EXISTING SYSTEMS AS INDICATED ON PLANS OR AS REQUIRED FOR INSTALLATION OF NEW WORK. MATERIAL SHALL BE REMOVED FROM SITE AND LEGALLY DISPOSED OF OFF SITE NLESS OTHERWISE DIRECTED. RETURN ITEMS TO WNER IN EXISTING CONDITION WHEN DIRECTED Y OWNER. OMPLETION OF WORK SHALL BE EXECUTED IN CCORDANCE WITH THE PROJECT SCHEDULE. CHEDULE INSTALLATION WITH OTHER TRADES TO NSURE PROJECT MILESTONES ARE MET. TURAL ELECTRICAL COMPONENT NOTES THE FOLLOWING ITEMS ARE TAKEN DIRECTLY FROM THE 2009 INTERNATIONAL BUILDING CODE AND FROM THE AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) STANDARD 7 -05. THE CONTRACTOR SHALL REFER TO THE ABOVE FOR ADDITIONAL INFORMATION, EXCEPTIONS, AND FURTHER DESCRIPTIONS. THE CONTRACTOR SHALL ADHERE TO REQUIREMENTS AND AS SUCH, SHALL BE INCLUDED WITHIN BID. ALSO REFER TO SPECIFICATIONS. 2. 2009 IBC. 1613.1. SCOPE: ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND NON- STRUCTURAL COMPONENTS THAT ARE PERMANENTLY ATTACHED TO STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS SHALL BE DESIGNED AND CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE MOTIONS IN ACCORDANCE WITH ASCE 7 -05, EXCLUDING CHAPTER 14 AND APPENDIX 11A. 3. 2009 IBC. 1709.1. CONTRACTOR RESPONSIBILITY: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONSTRUCTION OF A SEISMIC - FORCE- RESISTING SYSTEM, DESIGNATED SEISMIC SYSTEM, OR SEISMIC- RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL INSPECTIONS AND SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL INCLUDE THE FOLLOWING: A. ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS; B. ACKNOWLEDGMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL; C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE REPORTS; D. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION. 4. ELECTRICAL CONTRACTOR RESPONSIBILITIES: A. HANGERS AND SEISMIC BRACING FOR ELECTRICAL SYSTEMS SHALL BE DESIGNED AND SPECIFIED BY ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL REFER TO THE ELECTRICAL DRAWINGS FOR LOCATIONS OF EQUIPMENT AND ELECTRICAL SYSTEMS AS STRUCTURAL DRAWINGS DO NOT SHOW THE LOCATIONS OF ELECTRICAL EQUIPMENT, RACEWAYS, AND OTHER COMPONENTS. B. ELECTRICAL CONTRACTOR SHALL COORDINATE THE SUPPORT SYSTEMS AND DESIGN LOADS FOR HUNG RACEWAYS AND OTHER ELECTRICAL SYSTEMS (INCLUDING COMBINED MULTIPLE RACEWAY RUNS) WITH THE GENERAL CONTRACTOR AND THE STEEL AND WOOD JOIST MANUFACTURERS IN ADDITION TO OTHER TRADES THAT MAY BE IMPACTED. DRAWING INDEX E0.1 ELECTRICAL LEGEND E0.2 ELECTRICAL SPECIFICATIONS ED1.1 ELECTRICAL DEMOLITION PLAN E2.1 PARTIAL FIRST FLOOR LIGHTING PLAN E3.1 PARTIAL FIRST FLOOR POWER & SYSTEMS PLAN E3.2 PARTIAL ROOF POWER PLAN E9.1 ELECTRICAL ONE -LINE DIAGRAM £L(OO8 19 REVISIONS (D O N c) M 40 a;CO m "z1' L 00- 0 N .4- RECEIVED, CITY QF TUKK MLA OCT 1,3 2010 PERMIT CENTER ELECTRICAL LEGEND CT EQUIPMENT REPLACEMENT, ROOM 164 12844 MILITARY ROAD S NAC NO HEI NO DRAWN CHECKED DATE TECTURE x V cc 121 -10017 10113 TW DF 9 -10 -2010 SECTION 260500 SAL ELECTRICAL THE DRAWINGS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION 1 APPLY TO WORK UNDER THIS SECTION. PART 1- GENERAL: 1.1 DESCRIPTION: A. GENERAL: FURNISH ALL LABOR, MATERIALS, APPARATUS, TOOLS, EQUIPMENT, TRANSPORTATION, TEMPORARY CONSTRUCTION AND SPECIAL OR OCCASIONAL SERVICES AS REQUIRED TO MAKE A COMPLETE WORKING ELECTRICAL INSTALLATION, AS SHOWN ON THE DRAWINGS OR DESCRIBED IN THESE SPECIFICATIONS. B. WORK INCLUDED: 1. LIGHTING FIXTURES AND LAMPS. 2. GROUNDING. 3. PANELBOARDS AND OVERCURRENT DEVICES. 4. BRANCH CIRCUIT WIRING AND RACEWAYS. 5. RECEPTACLES. 6. TELEPHONE AND DATA OUTLETS AND RACEWAYS. 7. CONNECTIONS TO OWNER EQUIPMENT. 8. LIGHTING CONTROLS. 9. CONNECTIONS OF, AND POWER WIRING TO, HVAC EQUIPMENT. 10. CONDUIT FOR LOW VOLTAGE CABLING. 11. DEMOLITION. 12. ALL WORK AND MODIFICATIONS TO COMPLY WITH CODE AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.2 CODES AND STANDARDS: 1.3 A. SPECIFIC 1. COMPLY WITH ALL APPLICABLE CODES JURISDICTIONAL /LANDLORD REQUIREME 2. EQUIPMENT AND MATERIALS SPECIFIED SHALL CONFORM TO THE FOLLOWING APPLICABLE. a. UL UNDERWRITERS' LABORATORIES. b. ASTM AMERICAN SOCIETY FOR TESTING MATERIALS. c. CBM CERTIFIED BALLAST MANUFACTURERS. d. ANSI AMERICAN NATIONAL STANDARDS INSTITUTE. e. NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION AND NTS. UNDER THIS DIVISION STANDARDS WHERE DRAWINGS: A. LAYOUT: GENERAL LAYOUT SHOWN ON THE DRAWINGS IS DIAGRAMMATIC. COORDINATE WITH ARCHITECTURAL AND OTHER TRADES /OWNER VENDORS FOR EXACT LOCATION OF DEVICES /EQUIPMENT. B. ACCURACY: 1. DRAWINGS FOR THE WORK UNDER THIS SECTION ARE DIAGRAMMATIC AND COMPLETE DETAILS OF THE BUILDING WHICH AFFECT THE ELECTRICAL INSTALLATIONARE NOT SHOWN. COORDINATE WITH DRAWINGS OF ALL OTHER TRADES. 2. CONTRACTOR SHALL VERIFY LINES, LEVELS AND DIMENSIONS SHOWN ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE SETTING OUT OF WORK AND FOR ITS STRICT CONFORMANCE WITH EXISTING CONDITIONS AT THE SITE. 1.4 SUBSTITUTIONS: SUBSTITUTIONS OF SPECIFIED DEVICES AND EQUIPMENT SHALL NOT BE ALLOWED. 1.5 SUBMITTALS: A. GENERAL: REFER TO THE GENERAL CONDITIONS, SUPPLEMENTARY GENERAL CONDITIONS AND DIVISION 1 FOR REQUIREMENTS. B. FORMAT: FURNISH SUBMITTAL DATA NEATLY BOUND IN AN 8-1/2" X 11" FOLDER OR BINDER WITH A TABLE OF CONTENTS LISTING IN ORDER OF SPECIFICATION SECTION AND PARAGRAPH NUMBER. C. SUBMITTALS SHALL CONSIST OF DETAILED SHOP DRAWINGS, SPECIFICATIONS, CATALOG "CUTS" AND DATA SHEETS CONTAINING PHYSICAL AND DIMENSIONED INFORMATION, PERFORMANCE DATA, ELECTRICAL CHARACTERISTICS, MATERIALS USED IN FABRICATION, MATERIAL FINISH AND THOSE OPTIONAL ACCESSORIES WHICH ARE INCLUDED AND THOSE WHICH ARE EXCLUDED. D. EACH SUBMITTAL SHALL BE THOROUGHLY REVIEWED BY THE CONTRACTOR. THE COVER LETTER ACCOMPANYING SUBMITTAL LETTER SHALL LIST IN FULL THE ITEMS AND DATA SUBMITTED AND SHALL CONTAIN A STATEMENT ACKNOWLEDGING THAT THE CONTRACTOR HAS PERFORMED A DETAILED REVIEW OF THE SUBMITTAL DOCUMENTS PRIOR TO SUBMISSION. FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL CONSTITUTE GROUNDS FOR RETURN OF DATA FOR RESUBMISSION WITHOUT REVIEW. E. CONTRACTOR AGREES THAT SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS, THAT THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH EQUIPMENT AND MATERIAL HE INTENDS TO FURNISH AND INSTALL AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS HE INTENDS TO USE. 1.6 PRODUCT DELIVERY, STORAGE AND HANDLING: EQUIPMENT AND MATERIALS SHALL BE PROPERLY STORED AND ADEQUATELY PROTECTED AND CAREFULLY HANDLED TO PREVENT DAMAGE BEFORE AND DURING INSTALLATION. EQUIPMENT AND MATERIALS SHALL BE HANDLED, STORED, AND PROTECTED IN ACCORDANCE WITH THE MANUFACTURERS'S RECOMMENDATIONS AND AS APPROVED BY THE OWNER'S REPRESENTATIVE. ELECTRICAL CONDUIT SHALL BE STORED TO PROVIDE PROTECTION FROM THE WEATHER AND ACCIDENTAL DAMAGE. PLASTIC CONDUIT SHALL BE STORED ON EVEN SUPPORTS AND IN LOCATIONS NOT SUBJECT TO DIRECT SUN RAYS OR EXCESSIVE HEAT. CABLES SHALL BE SEALED, STORED AND HANDLED CAREFULLY TO AVOID DAMAGE TO THE OUTER COVERING OR INSULATION AND DAMAGE FROM MOISTURE AND WEATHER. DAMAGED OR DEFECTIVE ITEMS, IN THE OPINION OF THE OWNER'S REPRESENTATIVE, SHALL BE REPLACED WITH NEW ITEMS AT THE EXPENSE OF THE CONTRACTOR. 1.7 PERMITS AND FEES: PROVIDE, PROCURE AND PAY FOR ALL PERMITS, LICENSES AND FEES REQUIRED TO CARRY ON AND COMPLETE THE WORK. PART 2- PRODUCTS: (NOT APPLICABLE) PART 3- EXECUTION: 3.1 TESTS: A. TESTS SHALL BE CONDUCTED DURING THE CONSTRUCTION PERIOD AND AT COMPLETION TO DETERMINE CONFORMITY WITH APPLICABLE CODES AND WITH THESE SPECIFICATIONS. TESTS SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. INSULATION RESISTANCE: PERFORM 500 -VOLT D.C. TESTS FOR ONE MINUTE ON ALL FEEDER CONDUCTORS, INCLUDING THE NEUTRAL AND GROUND, AND MAKE A TYPED RECORD OF ALL READINGS TO BE INCLUDED IN THE MAINTENANCE INSTRUCTIONS. REPAIR OR REPLACE CIRCUITS SHOWING LESS THAN 40 MEGOHMS RESISTANCE TO GROUND. MAKE TESTS USING BIDDLE INSULATION RESISTANCE MEGGER, OR EQUAL. 2. GROUND RESISTANCE: TEST GROUND RESISTANCE PER IEEE STANDARD NO. 81. 3. CIRCUITS CONTINUITY: TEST ALL FEEDER AND BRANCH FOR CONTINUITY. TEST ALL NEUTRALS FOR IMPROPER GROUNDS. 4. EQUIPMENT OPERATIONS: TEST LIGHTING CIRCUITS FOR CORRECT OPERATION THROUGH THEIR CONTROL DEVICES. TEST ELECTRIC BASEBOARD HEATERS FOR CORRECT OPERATIONS THROUGH THEIR CONTROL RELAYS /THERMOSTATS. 5. LIGHTING CONTROL CIRCUITS: PERFORM OPERATION TESTS FOR ALL LIGHTING CIRCUITS. 6. PRODUCT FAILURE: ANY PRODUCTS WHICH FAIL DURING THE TESTS OR ARE RULED UNSATISFACTORY BY THE OWNER'S REPRESENTATIVE SHALL BE REPLACED, REPAIRED, OR CORRECTED AS PRESCRIBED BY THE OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. TESTS SHALL BE PERFORMED AFTER REPAIRS, REPLACEMENTS OR CORRECTIONS UNTIL SATISFACTORY PERFORMANCE IS DEMONSTRATED. 7. PHYSICAL INSPECTION OF ELECTRICAL EQUIPMENT AND CABLES: INSPECTION SHALL BE MADE OF ALL EQUIPMENT TO INSURE PROPER ASSEMBLY AND CONSTRUCTION. 3.2 INSTRUCTIONS AND MANUALS: A. REFER TO DIVISION 1. B. AT THE TIME OF COMPLETION, AN ADEQUATE PERIOD SHALL BE ALLOTTED BY THE CONTRACTOR FOR INSTRUCTION OF BUILDING OPERATING AND MAINTENANCE PERSONNEL IN THE USE OF ALL SYSTEMS. ALL PERSONNEL SHALL BE INSTRUCTED AT ONE TIME, THE CONTRACTOR MAKING ALL NECESSARY ARRANGEMENTS WITH MANUFACTURERS'S REPRESENTATIVES. THE EQUIPMENT MANUFACTURER SHALL PROVIDE PRODUCT LITERATURE AND APPLICATION GUIDES FOR THE USERS' REFERENCE. C. COSTS, FOR THE ABOVE SERVICE SHALL BE PAID BY THE CONTRACTOR. 3.3 PROJECT RECORD DOCUMENTS (AS- BUILT): A. PROVIDE PROJECT RECORD DRAWINGS AND SPECIFICATIONS AS REQUIRED BY OTHER SECTIONS OF SPECIFICATIONS AND AS REQUIRED HEREIN. SUCH DRAWINGS SHALL FULLY REPRESENT INSTALLED CONDITIONS INCLUDING ACTUAL LOCATION OF OUTLETS, CORRECT CONDUIT AND WIRE SIZING AS WELL AS ROUTING, REVISED FIXTURE SCHEDULING LISTING THE MANUFACTURER AND PRODUCTS ACTUALLY INSTALLED. B. ALL CHANGES TO DRAWINGS SHALL BE MADE BY QUALIFIED DRAFTSPERSONS TO MATCH EXISTING LINE WORK AND LETTERING AS CLOSELY AS POSSIBLE. 3.4 WORKMANSHIP: A. PREPARATION, HANDLING AND INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND TECHNICAL DATA PARTICULAR TO THE PRODUCT SPECIFIED AND /OR APPROVED EXCEPT AS OTHERWISE SPECIFIED. COORDINATE WORK AND COOPERATE WITH OTHER IN FURNISHING AND PLACING THIS WORK. WORK TO APPROVED SHOPDRAWINGS FOR WORK BY OTHERS AND TO FIELD MEASUREMENTS AS NECESSARY TO PROPERLY FIT THE WORK. B. CONFORM TO THE NATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATION STANDARD OF INSTALLATION FOR GENERAL INSTALLATION PRACTICE. 3.5 SCHEDULE OF WORK: ARRANGE WORK TO CONFORM TO THE SCHEDULE WHICH HAS BEEN ESTABLISHED FOR THE PROGRESS OF THE WORK. ADVISE REGARDING SHIPPING SCHEDULE OF MAJOR EQUIPMENT. 3.6 SUPERVISION: CONTRACTOR SHALL PERSONALLY OR THROUGH AN AUTHORIZED AND COMPETENT REPRESENTATIVE CONSTANTLY SUPERVISE THE WORK FROM BEGINNING TO COMPLETION AND, WITHIN REASON, KEEP THE SAME WORKMEN AND FOREMAN ON THE PROJECT THROUGHOUT THE PROJECT DURATION. 3.7 PROTECTION: KEEP CONDUITS, JUNCTION BOXES, OUTLET BOXES, AND OTHER OPENINGS CLOSED TO PREVENT ENTRY OF FOREIGN MATTER. COVER FIXTURES, EQUIPMENT AND APPARATUS AND PROTECT AGAINST DIRT, PAINT, WATER, CHEMICAL OR MECHANICAL DAMAGE, BEFORE AND DURING CONSTRUCTION PERIOD. RESTORE TO ORIGINAL CONDITION ANY FIXTURE, APPARATUS, OR EQUIPMENT DAMAGED PRIOR TO FINAL ACCEPTANCE. PROTECT BRIGHT FINISHED SURFACES AND SIMILAR ITEMS UNTIL IN SERVICE. NO RUST OR DAMAGE WILL BE PERMITTED. 3.8 SPECIAL TOOLS: ALL SPECIAL TOOLS FOR PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED UNDER THIS SECTION SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE. 3.9 CUTTING AND PATCHING: A. INSTALL ALL REQUIRED SLEEVES, FORMS AND INSETS BEFORE WALLS OR PARTITION ARE BUILT. CUTTING AND PATCHING OF WALLS, PARTITIONS, CEILINGS AND FLOOR NECESSARY FOR RECEPTION OF WORK, CAUSED BY FAILURE TO PROVIDE OR PROPERLY LOCATED SLEEVES, FORMS AND INSETS, INCORRECT LOCATION OF WORK OR FAILURE TO COOPERATE WITH OTHER TRADES, SHALL BE DONE AT EXPENSE OF TRADE RESPONSIBLE. B. NO CUTTING OF FINISHED OR STRUCTURAL WORK MAY BE DONE WITHOUT ACCEPTANCE. WHEN NECESSARY TO HAVE FINISHED MATERIAL OR STUCTURAL WORK CUT, FURNISH NECESSARY DRAWINGS TO TRADE WHOSE MATERIALS ARE OUT TO BE CUT. END OF SECTION SECTION 240510: BASIC MATERIALS AND METHODS THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION 1 APPLY TO WORK UNDER THIS SECTION. PART 1- GENERAL: 1.1 DESCRIPTION: A. WORK SPECIFIED IN THIS SECTION ENCOMPASSES PRODUCTS, ASSEMBLIES AND BASIC INSTALLATION METHODS REQUIRED FOR ELECTRICAL PROJECT SYSTEMS SPECIFIED UNDER THIS DIVISION AND INCLUDES, BUT IS NOT LIMITED TO: 1. CONDUIT, RACEWAYS, AND FITTINGS. 2. WIRE AND CABLES. 3. WIRE CONNECTIONS AND DEVICES. 4. OUTLET BOXES. 5. PULL AND JUNCTION BOXES. 6. SWITCHES AND RECEPTACLES. 7. DEVICE PLATES. 8. OVERCURRENT PROTECTIVE DEVICES. 9. TELEPHONE TERMINAL BACKBOARD. 10. LIGHT FIXTURES AND LAMPS. 11. CONDUIT FOR LOW VOLTAGE CABLING SYSTEMS. 12. EMPTY RACEWAY PROVISIONS FOR TELECOMMUNICATIONS SYSTEM. 13. PANELBOARDS AND ASSOCIATED EQUIPMENT. 1.2 SUBMITTALS: A. SUBMIT IN CONFORMANCE WITH THE REQUIREMENTS OF SECTION 240500 THE FOLLOWING ITEMS: 1. SWITCHES, RECEPTACLES AND DEVICE PLATES 2. CONDUCTORS AND CABLES. 3. OVERCURRENT PROTECTIVE DEVICES. 4. RACEWAYS. 5. PANELBOARDS. PART 2- PRODUCTS: 2.1 CONDUIT AND FITTINGS: A. ELECTRICAL METALLIC TUBING (EMT): 1. CONDUIT: SHALL BE FORMED OF COLD ROLLED STRIP STEEL, ELECTRICAL RESISTANCE WELDED CONTINUOUSLY ALONG THE LONGITUDINAL SEAM AND HOT -DIP GALVANIZED AFTER FABRICATION. CONDUIT SHALL CONFORM TO ANSI C80.3 SPECIFICATIONS AND SHALL MEET U.L. REQUIREMENTS. 2. COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON, GLAND COMPRESSION TYPE, U.L. LISTED RAIN AND CONCRETE TIGHT THROUGH 1-1/4 INCH TRADE SIZE, O.Z. /GEDNEY 6050W SERIES, EFCOR 760 SERIES OR EQUAL. SET SCREW TYPE COUPLINGS MAY BE USED IN DRY LOCATIONS, O.Z. /GEDNEY 5050 SERIES OR EQUAL. 3. CONNECTORS: GLAND COMPRESSION TYPE WITH CAST MALLEABLE IRON BODY WITH MALE HUB AND INSULATED PLASTIC THROAT 150 DEGREES C. TEMPERATURE RATED. O.Z. /GEDNEY 4050 SERIES OR EQUAL. 2.4 SWITCHES AND RECEPTACLES: A. B. C. GENERAL: COLOR OF DEVICES SHALL MATCH EXISTING CONDITIONS. 1. EMERGENCY DEVICES: RED. 2. NORMAL POWER DEVICES: IVORY. RECEPTACLES: 1. ALL RECEPTACLES SHALL BE HOSPITAL GRADE. 2. DUPLEX RECEPTACLE: (20A -125V NEMA 5 -20R STRAIGHT BLADE GROUNDING TYPE: HUBBELL MODEL 8300 -(I /R) OR EQUAL. 3. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE: HUBBELL MODEL GFR8300H(I /R)L OR EQUAL. SWITCHES: WALL SWITCHES FOR LIGHTING CIRCUITS: NEMA WD 1; AC GENERAL USE SNAP SWITCH WITH TOGGLE HANDLE, RATED 20 AMPERES AND 120/277 VOLTS AC. SWITCH SHALL HAVE BACK AND SIDE WIRED SCREW TYPE TERMINALS. UNITS TO BE SPECIFICATION GRADE. 1. SINGLE -POLE TOGGLE SWITCH: HUBBELL MODEL CSB120 (I /R) OR EQUAL. 2. THREE -WAY TOGGLE SWITCH: HUBBELL MODEL CSB320 (I /R) OR EQUAL. 3. FLUORESCENT WALL BOX DIMMER SWITCH: LUTRON NOVA T SERIES. CONFIGURATION SHALL MATCH EXACT BALLAST INSTALLED. 2.5 DEVICE PLATES: REVIEWED FOR COMPLIANCE WITH NFPA70 NEC UC1 2 8 2010 City o .Tukw la BUILDING DIVISION C. FLEXIBLE METALLIC CONDUIT: 1. CONDUIT: SHALL BE FABRICATED IN CONTINUOUS LENGTHS FROM GALVANIZED STEEL STRIP, SPIRALLY WOUND AND FORMED TO PROVIDE AN INTERLOCKING DESIGN. 6' MAX. LENGTH FLEXIBLE CONDUIT IS NOT PERMITTED IN WALLS. 2. FITTINGS: CONNECTORS SHALL BE MADE OF THE SCREW CLAMP WITH CAST MALLEABLE IRON BODIES AND THREADED MALE HUBS WITH INSULATED THROATS. 3. FLEXIBLE CONDUIT SHALL ONLY BE ALLOWED IN THE LENGTHS AND FOR APPLICATIONS AS ALLOWED BY THE JURISDICTION AND LANDLORD. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING INSTALLATION THAT IS NOT IN COMPLIANCE WITH THE JURISDICTIONAL AND LANDLORD REQUIREMENTS D. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT: 1. CONDUIT: ANACONDA TYPE U.A., COLEMAN TYPE UXT1 OR EQUAL. 2. FITTINGS: CONNECTOR BODY AND GLAND NUT SHALL BE OF CADMIUM PLATED CAST MALLEABLE IRON, WITH INSULATED THROAT, MAX. 24 ", T & B 5331 SERIES, O.Z. /GEDNEY 4Q -38 -1T SERIES, OR EQUAL. E. MINIMUM ACCEPTABLE CONDUIT SIZE SHALL BE 1/2 INCH. F. MC CABLING - NOT ALLOWED. 2.2 WIRE AND CABLE: A. GENERAL: 3. CONDUCTOR MATERIAL: ALL WIRE AND CABLE SHALL BE INSULATED COPPER CONDUCTORS FOR ALL WIRE SIZES. ALUMINUM WIRE AND CABLE SHALL NOT BE USED. 4. INSULATION: INSULATION SHALL BE THWN -THHN. 5. MINIMUM CONDUCTOR SIZE: a. POWER AND LIGHTING BRANCH CIRCUITS: #12 AWG b. SIGNAL AND CONTROL CIRCUITS UNDER 100 VOLTS: #14 AWG c. ANY 120V./ 20A. CIRCUITS OVER 75 L.F. MUST BE: #10 AWG 6. COLOR CODE. COLOR CODE ALL CONDUCTORS IN ACCORD WITH NEC AS FOLLOWS: 120/208V 277/480V PHASE A BLACK BROWN PHASE B RED ORANGE PHASE C BLUE YELLOW NEUTRAL WHITE GRAY 2.3 OUTLET BOXES AND COVERS: A. STANDARD OUTLET BOXES: GALVANIZED, ONE- PIECE, DRAWN STEEL, KNOCK -OUT TYPE OF SIZE AND CONFIGURATION BEST SUITED TO THE APPLICATION INDICATED ON THE PLANS. MINIMUM BOX SIZE, 4 INCH SQUARE BY 1-1/2 INCH DEEP. B. SWITCH BOXES: TWO INCH BY 3 -INCH LONG, GALVANIZED STEEL SWITCH BOXES SHALL BE USED ONLY FOR THE INSTALLATION OF SINGLE SWITCHES, INSTALL MULTIPLE SWITCHES IN STANDARD GANG BOXES WITH RAISED DEVICE COVERS SUITABLE FOR THE APPLICATION INDICATED. A. B. C. FLUSH DEVICE PLATES: PLATES SHALL SMOOTH PLASTIC. PLATE FINISH SHALL MATCH WIRING DEVICE COLOR. OUTDOOR, WEATHERPROOF: DIE CAST ALUMINUM CONSTRUCTION, CORROSION RESISTANT, HEAVY DUTY, HINGED COVER FLAP, AND GASKET, WHILE -IN -USE CONSTRUCTION. RED -DOT CODE KEEPER SERIES OR EQUAL. CIRCUIT LABELING: DEVICE COVERPLATES SHALL BE LABELED SHOWING PANEL NAME AND CIRCUIT NUMBER THEY ARE SERVED FROM. LABEL SHALL BE CLEAR, NON- ERASABLE X" TAPE WITH TYPED 1/8" LETTERS FASTENED TO THE BOTTOM OF THE COVERPLATE. 2.6 DISCONNECT SWITCHES: A. B. C. D. SWITCH INTERIOR: DEAD -FRONT CONSTRUCTION WITH HINGED ARC SUPPRESSOR AND SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF " POSITION AND WITH DOOR OPEN. SWITCH MECHANISM: QUICK -MAKE AND QUICK -BREAK OPERATING HANDLE AND MECHANISM WITH DUAL COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR IN THE "ON" POSITION OR CLOSING THE SWITCH MECHANISM WHILE THE DOOR IS OPEN. RATINGS: SWITCHES SHALL BE HORSEPOWER RATED FOR THE OPERATING VOLTAGE AND WITH FUSED OR NON -FUSED ARRANGEMENTS AS SHOWN ON THE DRAWINGS. ENCLOSURES: NEMA 1, CODE GAUGE SHEET STEEL WITH HINGED COVER, OR NEMA 3R AS SHOWN ON DRAWINGS, AND AS REQUIRED BY APPLICATION. 2.9 PROTECTIVE DEVICES: A. CIRCUIT BREAKERS: MOLDED CASE, BOLT -ON, THERMAL MAGNETIC TYPE, 40 DEGREES C. AMBIENT TEMPERATURE COMPENSATED, FIXED MOUNTING, WITH QUICK -MAKE AND QUICK -BREAK SWITCHING MECHANISM MECHANICALLY TRIP -FREE FROM THE OPERATING HANDLE. B. RATINGS: REFER TO DRAWINGS AND PANEL SCHEDULES FOR TRIP FRAME AND POLES REQUIRED. EQUIPMENT SHALL BE FULLY RATED BASED ON AVAILABLE FAULT CURRENT LEVEL. 2.10 ELECTRICAL SUPPORTING DEVICES: A. B. C. CONDUIT STRAPS: HOT -DIP GALVANIZED, CAST MALLEABLE IRON, ONE HOLE TYPE STRAP WITH CAST CLAMP -BACKS AND SPACERS AS REQUIRED. O.Z. /GEDNEY #14 -50G STRAP AND #141G SPACER, REFCOR #231 STRAP AND #131 SPACER, OR EQUAL. CONSTRUCTION CHANNEL: 1-1/2 INCH BY 1-1/2 INCH 12 GAUGE GALVANIZED STEEL CHANNEL WITH 17/32 INCH DIAMETER BOLT HOLES, 1-1/2 INCHES ON CENTER, IN BASE OF THE CHANNEL. KINDORF 905 SERIES, UNISTRUT P- 1000 -HS, OR EQUAL. FASTENERS (GENERAL): WOOD SCREWS FOR FASTENING TO WOOD. MACHINE SCREWS FOR FASTENING TO STEEL. TOGGLE BOLTS FOR FASTENING TO HOLLOW CONCRETE BLOCK, GYPSUM BOARD OR PLASTER WALL. EXPANSION ANCHORS FOR ATTACHMENTS TO PRE - POURED CONCRETE. 2.11 IDENTIFYING DEVICES: A. PANELBOARD DIRECTORIES: SHALL BE TYPEWRITTEN, ARRANGED IN NUMERICAL ORDER AND SHALL SHOW THE NUMBER OF THE CIRCUIT IS INDICATED. THE ROOM NUMBERS USED SHALL BE VERIFIED WITH THE OWNER AND SHALL NOT NECESSARILY BE THOSE USED IN THE DRAWINGS. MOUNT DIRECTORIES IN A 6" X 8" METAL FRAME UNDER PLEXIGLASS INSIDE EACH PANELBOARD. B. WIRE & TERMINAL MARKERS: SELF - ADHERING, PRE - PRINTED VINYL WITH SELF - LAMINATING WRAP GROUND STRIP BRADY B191 SERIES, THOMAS & BETTS WSI SERIES, OR EQUAL. 2.13 GROUNDING: A. ENCLOSURES OF EQUIPMENT, RACEWAYS, AND FIXTURES SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED. PROVIDE CODE- SIZED, (UNLESS OTHERWISE INDICATED) COPPER, INSULATED GREEN EQUIPMENT GROUND WITH ALL BRANCH AND FEEDER CIRCUIT RUNS. EQUIPMENT GROUND SHALL ORIGINATE AT PANELBOARD GROUND BUS AND SHALL BE BONDED TO ALL SWITCH AND RECEPTACLE BOXES AND ELECTRICAL EQUIPMENT ENCLOSURES. PART 3- EXECUTION: 3.1 CONDUIT AND RACEWAY APPLICATIONS: A. ELECTRICAL METALLIC TUBING (EMT): INTERIOR POWER AND LIGHTING BRANCH CIRCUITS WHERE RUN CONCEALED ABOVE SUSPENDED CEILING, IN STUD WALLS, FURRED SPACES, AND WHERE NOT EXPOSED TO MECHANICAL DAMAGE, OR ABOVE 6' FROM FLOOR. B. FLEXIBLE METALLIC CONDUIT: IN DRY LOCATIONS CONNECTION TO TRANSFORMERS, (6' MAX.), VIBRATING EQUIPMENT (24" MAX.), AND TO RECESSED LIGHTING FIXTURES. C. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT: IN DAMP AND WET LOCATIONS FOR CONNECTION TO ALL PUMP MOTORS, SOLENOID VALVES, HVAC EQUIPMENT AND SIMILAR DEVICES SHALL BE MADE USING LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. PROVIDE SEPARATE GROUND WIRE INDEPENDENT OF CONDUIT, RUN INSIDE CONDUIT AND BONDED AT BOTH ENDS TO ENCLOSURES. MAXIMUM LENGTH OF 24 INCHES. 3.2 CONDUIT INSTALLATION: A. GENERAL: 1. CONDUIT SYSTEM SHALL BE CONCEALED UNLESS EXPOSED WORK IS CLEARLY CALLED FOR ON DRAWINGS. 2. CONDUITS SHALL BE TIGHTLY COVERED AND WELL PROTECTED DURING CONSTRUCTION USING METALLIC BUSHINGS AND BUSHING "PENNIES" TO SEAL OPEN ENDS. 3. IN ALL EMPTY CONDUITS OR DUCTS, INSTALL A 200 -POUND TENSILE STRENGTH POLYETHYLENE PULLING ROPE. 4. CONDUIT SYSTEMS SHALL BE ELECTRICALLY CONTINUOUS THROUGHOUT. INSTALL CODE SIZE, INSULATED, COPPER, GREEN GROUNDING CONDUCTOR IN ALL CONDUIT RUNS PULLED WITH PHASE AND NETURAL CONDUCTORS. REVISIONS CO 0 d' cci ca co N N w9- B. LAYOUT: 1. LOCATIONS OF CONDUIT RUNS SHALL BE PLANNED IN ADVANCE OF THE INSTALLATION AND COORDINATED WITH THE DUCTWORK, PLUMBING, CEILING AND WALL CONSTRUCTION IN THE SAME AREAS AND SHALL NOT UNNECESSARILY CROSS OTHER CONDUITS OR PIPE, NOR PREVENT REMOVAL OF CEILING OR TILES OR PANELS, NOR BLOCK ACCESS TO MECHANICAL OR ELECTRICAL EQUIPMENT. C. SUPPORTS: 1. ALL RACEWAY SYSTEMS SHALL BE SECURED TO THE BUILDING STRUCTURES USING SPECIFIED FASTENERS, CLAMPS AND HANGERS SPACED ACCORDING TO CODE REQUIREMENTS. 2. SUPPORT SINGLE RUNS OF CONDUIT USING ONE HOLE PIPE STRAPS. WHERE RUN HORIZONTALLY ON WALLS IN DAMP OR WET LOCATION, INSTALL "CLAMP- BACKS" TO SPACE CONDUIT OFF THE SURFACE. D. TERMINATION AND JOINTS: 1. RACEWAYS SHALL BE JOINED USING SPECIFIED COUPLING OR TRANSITION COUPLINGS WHERE DISSIMILAR RACEWAY SYSTEMS ARE JOINED. 2. CONDUITS SHALL BE SECURELY FASTENED TO CABINETS, BOXES AND GUTTERS USING TWO LOCKNUTS AND AN INSULATING BUSHING OR SPECIFIED INSULATED CONNECTORS. INSTALL GROUNDING BUSHINGS OR BONDING JUMPERS ON ALL CONDUITS TERMINATING AT CONCENTRIC KNOCKOUTS. 3. CONDUIT TERMINATIONS EXPOSED AT WEATHERPROOF ENCLOSURES AND CAST OUTLET BOXES SHALL BE MADE WATERTIGHT USING SPECIFIED CONNECTORS AND HUBS. E. PENETRATIONS: 1. ALL FLOOR PENETRATIONS SHALL BE SEALED WATER- TIGHT. MAINTAIN FIRE RATING AS REQUIRED. 2. FIRE -SAFE ALL RATED WALL PENETRATIONS USING 3M LISTED FIRE- SAFING SEALANTS AND ASSEMBLIES. 3.3 CABLE AND WIRE INSTALLATION: A. GENERAL: 1. CONDUCTORS SHALL NOT BE INSTALLED IN CONDUIT UNTIL ALL WORK OF ANY NATURE THAT MAY CAUSE DAMAGE IS COMPLETED. CARE SHALL BE TAKEN IN PULLING CONDUCTORS THAT INSULATION IS NOT DAMAGED. U.L. APPROVED NON - PETROLEUM BASE AND INSULATING TYPE PULLING COMPOUND SHALL BE USED AS NEEDED. 2. ALL CABLES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND WARRANTY. B. SPLICING AND TERMINATING: 1. ALL ASPECTS OF SPLICING AND TERMINATING SHALL BE IN ACCORDANCE WITH CABLE MANUFACTURER'S PUBLISHED PROCEDURES. 2. MAKE UP ALL SPLICES IN OUTLET BOXES WITH CONNECTORS AS SPECIFIED HEREIN WITH SEPARATE TAILS OF CORRECT COLOR TO BE MADE UP TO SPLICE. PROVIDE AT LEAST SIX (6) INCHES OF TAILS PACKED IN BOX AFTER SPLICE IS MADE UP. 3. ALL WIRE AND CABLE IN PANELS, TERMINAL CABINETS AND EQUIPMENT ENCLOSURES SHALL BE BUNDLED AND CLAMPED. B. C. B. BUILDING SERVICES SHALL BE GROUNDED TO BUILDING STEEL AND TO COLD METALLIC WATER PIPING. RECEIV%D CITY OF TU 1-A► ,T 1,3 2010 PERMIT CENTER BOXES LAYOUT: 1. OUTLET BOXES SHALL BE INSTALLED AT THE LOCATIONS AND ELEVATIONS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. MAKE ADJUSTMENTS TO LOCATIONS AS REQUIRED BY STRUCTURAL CONDITIONS AND TO SUIT COORDINATION REQUIREMENTS OF OTHER TRADES. 2. WHERE INSTALLATION IS WITHIN OR BEHIND CASEWORK, COORDINATE EXACT LOCATION WITH CASEWORK CONTRACTOR PRIOR TO ROUGH -IN TO ENSURE ACCESSIBILITY. SUPPORTS: 1. BOXES INSTALLED IN STUD WALLS SHALL BE EQUIPPED WITH BRACKETS DESIGNED FOR ATTACHING DIRECTLY TO THE STUDS OR SHALL BE MOUNTED ON HEAVY GAUGE GALVANIZED STEEL BOX SUPPORTS. 2. FIXTURE OUTLET BOXES INSTALLED IN SUSPENDED CEILINGS OF GYPSUM BOARD OR LATH AND PLASTER CONSTRUCTION SHALL BE MOUNTED TO 16 GAUGE METAL CHANNEL BARS ATTACHED TO MAIN CEILING RUNNERS. 3. FIXTURE OUTLET BOXES INSTALLED IN SUSPENDED CEILINGS SYSTEMS SUPPORTING ACOUSTICAL TILES OR PANELS SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURES ABOVE WHEREVER PENDANT - MOUNTED FIXTURES ARE INSTALLED FROM THE BOX. END OF SECTION ECTR AL SPECIFICATIONS 0 ELto-O x- 2 0 0 Z U -J 0 w i- Z uJ 2 0 U u w MIN Z co ca.) NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 TW DF 9 -10 -2010 O.2 XISTIN G 2X4 TROF )RAGE -007 XISTING INCANDESCENT ,QUAR DO ► LIGHT TIP) 1 N E9Ci PARTIAL FIRST FLOOR LIGHTING DEMOLITION PLAN Scale: 1/4" = 1' -0" 0 1 2 4 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 2 8 2010 City of Tukwila O RAG -007 EXISTING NURSE CALL NCY STATION EXISTING WALL PHONE 0 -F -I C 1008 J TT +65" AC2'• ,28 1"_ - AC2 -26 TT CT SCAN ROO V 1006 6/1.6 +65' - AC2 -26 +65" BUILDING DIVISION )7/7/ i '''V -STI B 1009 7 AC2 -26 EXISTING PUSH START / /STOP BUTTON EXISTING WALL PHONE +57" C O N T "\-) 1005 J. 1017 S.T. 1011 010 EXISTING 10" X 3-1/2" WIREWAY EXISTING CT 200A/ ENCLOSED CIRC,J T BREAKER 11 II 11 if EXIS aG 10" X 3- WIR SPECIAL RECEPTACLE N C!D PARTIAL FIRST FLOOR POWER AND SYSTEMS DEMOLITION PLAN 2 Scale: 1 /4" = 1' -0" 8 rLJ I 0 1 2 4 8 DEMOLITION SHEET NOTES: 1. REFER TO ARCHITECTURAL FLOOR PLANS FOR WALL AND FLOOR FINISHES BEING REMOVED. IN EFFECTED AREAS, REMOVE DEVICE TRIM AND DISCONNECT ITEMS AS REQUIRED FOR REMOVAL OF INDICATED FINISHES. REINSTALL AT NEW FINISHES. FIELD VERIFY QUANTITY OF DEVICES WITH GENERAL CONTRACTOR. 2. COORDINATE DEMOLITION WORK WITH GENERAL CONTRACTOR. 3. REFER TO ARCHITECTURAL AND MECHANICAL DRAWINGS FOR RELATED DEMOLITION REQUIREMENTS. 4. THROUGHOUT CONSTRUCTION, MAINTAIN CONTINUITY OF ALL ELECTRICAL AND COMMUNICATIONS WIRING AND SERVICES TO ALL ITEMS WHICH ARE REQUIRED FOR NORMAL FACILITY OPERATION. ANY REQUIRED INTERRUPTION OF THESE SERVICES SHALL BE FULLY COORDINATED WITH THE FACILITY MAINTENANCE MANAGER. 5. EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE REMOVED SHALL HAVE SERVING BRANCH CIRCUIT WIRING, LOW VOLTAGE CABLING AND CONDUIT FULLY REMOVED BACK TO THE POINT OF SERVICE. FOR CIRCUITS THAT ARE RE —USED AFTER THE DEMOLITION PHASE, REMOVE CONDUIT AND CABLING BACK TO CIRCUIT JUNCTION BOX ABOVE CEILING. 6. DRAWINGS ARE SCHEMATIC. EXTENT OF DEMOLITION SHOWN IS APPROXIMATE. FIELD VERIFY EXISTING CONDITIONS AND DEMOLITION REQUIREMENTS. 7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTED LIGHTS AND DEVICES. LIGHT FIXTURES (INCLUDING LAMPS /BALLAST) THAT ARE SCHEDULED FOR REMOVAL SHALL BE DISPOSED OF BY THE CONTRACTOR UNLESS OTHERWISE NOTED ON THE LIGHTING PLAN. CERTIFY IN WRITING THAT THE TRANSPORTATION, STORAGE, PROCESSING, AND DISPOSAL METHODS OF ALL LAMPS /BALLASTS ARE IN ACCORDANCE WITH ALL LOCAL, COUNTY, STATE, AND NATIONAL ORDINANCES AND REQUIREMENTS. 8. PANEL BOARDS WHICH ARE AFFECTED BY THIS PROJECT SHALL BE THOROUGHLY CLEANED AND VACUUMED TO REMOVE DIRT AND DEBRIS PRIOR TO PROJECT CLOSE OUT. ALL CONDUCTORS WITHIN PANEL BOARD SHALL BE NEATLY ORGANIZED USING CABLE TIES. SPLICES IN PANEL BOARD ARE NOT ALLOWED. REMOVE ALL UNUSED CONDUCTORS FROM PANEL BOARD. PROVIDE NEW PANEL CARDS UPDATED TO CURRENT CONDITIONS AT THE END OF THE PROJECT. REMOVE ALL ERRONEOUS MARKINGS FROM EXISTING PANEL DOORS AND COVERS. THE EXISTING DEVICE /EQUIPMENT LOCATIONS SHOWN ON THE DEMOLITION DRAWINGS ARE BASED ON THE RECORD DRAWINGS. THE SUBCONTRACTORS ARE RESPONSIBLE FOR VERIFYING THE ACTUAL LOCATIONS FOR ALL EXISTING DEVICES TO DETERMINE THE EXTENT OF THE DEMOLITION WORK REQUIRED. VERIFY ALL BRANCH CIRCUIT NUMBERS SERVING ALL EXISTING DEVICES AND EQUIPMENT LOCATED IN THE AREAS OF DEMOLITION. 10. REMOVE ALL CONDUITS, WIRE, AND CABLES BEING DEMOLISHED. ABANDONING IN PLACE IS NOT ALLOWED. FLAG NOTES: ELI RELOCATE EXISTING DEVICE TO LOCATION SHOWN. PROVIDE NEW ROUGH —IN BACK BOX, CONDUIT UP TO CEILING SPACE AND EXTENSION OF EXISTING CABLING AS REQUIRED. FOR TELECOMMUNICATIONS DEVICES SCHEDULED FOR DEMOLITION, REMOVE CABLING FROM DEVICE AND COIL ABOVE THE CEILING FOR FUTURE INSTALLATION. REPLACE EXISTING DEVICE WITH HOSPITAL GRADE, GFCI RECEPTACLE. REMOVE WIREWAY EXTENSION BACK TO LOCATION WHERE TEE OCCURS. REFERENCE NEW WORK PLANS FOR EXTENT OF WIREWAY REQUIRED FOR NEW INSTALLATION. REMOVE CIRCUIT AC2 -26 FROM EXISTING QUAD RECEPTACLE. EXISTING RECEPTACLE SHALL BE FED BY AC2 -28 ONLY. PROVIDE NEW CIRCUIT LABEL: 'AC2 -28'. N REVISIONS ANEMIA LA KEY PLAN OCT 13 2010 (1-i NOT TO SCALE PERMIT CENTER 0 U ELECTRICAL DEMOLITION PLAN 8 N 0 0 z W 2 W U 0 W Z W 2 0 0 W U TECTURE RC Q NAC NO 121 -10017 HEINO 10113 DRAWN TW CHECKED DF DATE 9 -10 -2010 ED BID ALTERNATE #3 L N 1 PARTIAL FIRST FLOOR LIGHTING PLAN Scale: 1/4" = 1' -0" O1 2 4 8 LIGHT FIXTURE SCHEDULE NO. DESCRIPTION MANUFACTURER LAMP VOLT W LOCATION NOTES NAME CATALOG NO. QTY. TYPE A 2' X 2' - 2 LAMP RECESSED GRID LAY -IN FLUORESCENT WITH Al 9 ACRYLIC LENS, REGRESSED ALUMINUM DOOR STYLE, SPRING LOADED LATCHES, WHITE FINISH, 2 -LAMP INSTANT START ELECTRONIC BALLAST. COLUMBIA 4PS22- 232U6G- RAA19 -EU -SLL 2 FU32 T8 3500' 120/ 277V 59 CT ROOM B 8" - HORIZONTAL (2) LAMP QUAD TUBE FLUORESCENT DOWNLIGHT WITH CLEAR ALZAK REFLECTOR, AMERICAN MATTE FINISH, DIFFUSED LENS, 2- LAMP LUTRON (COMPACT SE) ELECTRONIC DIMMING BALLAST. PRESCOLITE CFR818UEB- (LUTRON COMPACT SE)- ST492A- MFC- DIFFUSED LENS 2 18W QUAD 4 -PIN 3500' 120/ 277V 38 CT ROOM C 2' X 4' - 2 LAMP RECESSED GRID LAY -IN FLUORESCENT WITH Al 2 ACRYLIC LENS, REGRESSED ALUMINUM DOOR STYLE, SPRING LOADED LATCHES, WHITE FINISH, 2 -LAMP LUTRON (ECO -10) ELECTRONIC DIMMING BALLAST. (NOTE 3) COLUMBIA 4PS24- 232G- RAA12- ( LUTRON ECO -10) -SLL 2 F32 T8 3500' 120/ 277V 59 CT ROOM NOTE: 1. MANUFACTURERS LABELS SHALL NOT BE VISIBLE FROM THE FLOOR FOR ALL LIGHT FIXTURES. 2. ALL LIGHT FIXTURES SHALL BE LOCATED AS TO NOT OBSTRUCT SPRINKLER HEAD SPRAY PATTERNS PER NFPA. 3. IN ADDITION TO STANDARD ARYLIC LENS, PROVIDE OPAL ACRYLIC, 0.125 "MIN LENS. LENS SHALL BE DELIVERED TO THE OWNER FOR CUSTOM IMAGE SILK SCREEN. PROVIDE FINAL LENS INSTALLATION AS DIRECTED BY OWNER. SHEET NOTES= 1. REFERENCE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING MOUNTED DEVICES. FLAG NOTES: CIRCUIT NEW LIGHT FIXTURES TO EXISTING LIGHTING CIRCUIT FOR THIS ROOM. FIELD VERIFY EXISTING CIRCUIT NUMBER, AND PROVIDE UPDATED INFORMATION ON AS -BUILT DRAWINGS. tiEVIEWED FOR COMPLIANCE WITH NFPA 70 NEC OCT 282010 EL1OO 318 KEY PLAN NOT TO SCALE RECEIV�J,p CITY OF TUKWILA OCT 1 2010 PERMIT CENTER PARTIAL FIRST FLOOR LIGHTING PLAN V cc NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 TW DF 9 -10 -2010 STORAGE 120 EFMERGENCY-STATI EXISTING LLI ONE 63 IBUL 160 J. 118 S.T. 161 +65" AC2 -28 +65" AC2 -28 INV rte= • 04511q 10/26/1 0i6n 1 C9/16n'416%/4�/29/16n 2 CP /i6nEVI6VFid�/zW /sn 3 I -I, L_ 1 AC2 -261 A) ••• J 0 NT ■ AC2 -28 PARTIAL FIRST FLOOR POWER & SYSTEMS PLAN I1 E1 A I 10,3 1 Scale: 1/4" = 1' -0" STO -SAG 120 2 CONNECT TO CRITICAL POWER CIRCUIT IN ROOM, 0 =I C 'P2 -28 163 v = STIBUL.: 160 J 10" X 3-1/2" SURFACE C R- - +CT WIT 2 DIV1D ' 'S (a,OINNACk EXISTI �. IR Y) NC. L 10 "X3 -1I12 SUR-FAGE WALL DUC WITH \2 DIVIDERS (CONNECT TO EXISTING \ WIREWAY) J. 118 S.T. 161 / INJECTOR BACK BOX PR IDE 6 "X6 "X4" BOX RECESSED IN C ROOM mum el:TA „I COVE PLATE WITH —1/2" CHASE NIPPLE. T. % 62 ,O / C91 ,J1S 1 C9 /6n13/i61/2 ▪ •s /fin 2 C9/6n'4161/2 d/ ' isn 3 165 CT EQUIPMENT PLAN 0 1 2 4 EXISTING 10" X 3-1/2" WIREWAY INJ PR RE PR WITH NIPP ALL 103 8 I l TOR BACK BOX IDE 6 "X6 "X4" BOX SSED IN WALL IDE COVERPLATE 2 -1/2" CHASE E. CT EQUIPMENT LEGEND: ENCLOSED CIRCUIT BREAKER • REMOVE EXISTING 200A CIRCUIT BREAKER. • PROVIDE 90A, 3 —POLE BREAKER WITH SHUNT TRIP ACCESSORY. • MOUNT NEW BREAKER WITHIN EXISTING ENCLOSURE. A. IF NEW SHUNT TRIP BREAKER WILL NOT FIT WITHIN EXISTING ENLCOSURE, PROVIDE NEW ENCLOSURE. • MOUNT EXISTING ENCLOSURE IN NEW FURRED OUT WALL. A. REUSE EXISTING INCOMING CONDUIT AND WIRE FEEDER WHERE POSSIBLE. B. IF MOUNTING LOCATION REQUIRES ADDITIONAL FEEDER LENGTH, PROVIDE PULL BOX WITH REMOVABLE COVER BELOW ENCLOSURE. SPLICE AND EXTEND EXISTING FEEDER AS REQUIRED. O CT SCANNER • PROVIDE 12" COVERPLATE WITH 8 "x8" GROMMETED OPENING IN NEW FLOOR DUCT. O OPERATORS CONSOLE • PROVIDE 12" COVERPLATE WITH 3 "x3" GROMMETED OPENING IN EXISTING WIREWAY. KEM POWER DISTRIBUTION UNIT • PROVIDE 12 "HX12"WX4 "D BOX, RECESSED IN WALL FOR CONNECTION OF MAIN DISCONNECT TO PDU. A. PROVIDE 2-1/2" CONDUIT CONNECTION BETWEEN DISCONNECT AND BOX. B. PROVIDE COVERPLATE WITH 2 -1/2" CHASE NIPPLE. C. PROVIDE 6FT OF 2 -1/2" FLEXIBLE METAL CONDUIT FOR CONNECTION TO NIPPLE IN THE COVERPLATE. E. PROVIDE (2) 2 -1/2" 90 DEGREE CONNECTORS. F. (3) #1/0 & (1) #1 /OGND, CABLE TERMINATED AT THE DISCONNECT. • PROVIDE 12" COVERPLATE WITH 8 "x8" GROMMETED OPENING IN NEW WALL DUCT FOR CONNECTION OF PDU TO CT GANTRY. • PROVIDE 4 "Hx4"Wx4 "D BOX, RECESSED IN WALL FOR CONNECTION OF PDU TO WARNING LIGHT CONTROLLER. A. PROVIDE COVERPLATE WITH (1)1/2" CHASE NIPPLE. B. PROVIDE 6FT OF 1/2" FLEXIBLE METAL CONDUIT FOR CONNECTION TO NIPPLE IN THE COVERPLATE. C. PROVIDE (2) 1/2" 90 DEGREE CONNECTORS. EMERGENCY OFF • REMOTE SWITCH FOR OPERATION OF SHUNT TRIP FEATURE ON MAIN BREAKER. PROVIDE EPO PUSH — BUTTON WITH PROTECTIVE COVER, SQ —D TYPE K, CLASS 9001 CAT # KR9P1RH13, PROVIDE QUANTITY OF NO /NC CONTACTS AS REQUIRED FOR EQUIPMENT INTERCONNECTIONS WITH HINGED, CLEAR PROTECTIVE COVER. UPS CABINET (PROVIDED UNDER BID ALTERNATE #2) • PROVIDE 4 "Hx4 "Wx4 "D BOX, RECESSED IN WALL FOR CONNECTION OF UPS SHUTDOWN CIRCUIT TO MAIN DISCONNECT. • PROVIDE COVERPLATE WITH (1)1/2" CHASE NIPPLE. • PROVIDE 6FT OF 1/2" FLEXIBLE METAL CONDUIT FOR CONNECTION TO NIPPLE IN THE COVERPLATE. • PROVIDE (2) 1/2" 90 DEGREE CONNECTORS. WARNING LIGHT • PROVIDE WARNING LIGHT ABOVE ENTRANCE DOOR. • DUAL —LITE, CAT# SE— S— R— W —SW57. "CT IN USE ". WARNING LIGHT CONTROLLER • PROVIDE RELAY FOR CONTROL OF WARNING LIGHT. • 120V CIRCUIT INPUT /OUTPUT • 24V/2 —WIRE CONTROL INPUT FROM X —RAY GENERATOR. RACEWAY AND WIRING LEGEND: (1)1/2 "C, (2) #12 BLACK, (1) #12 GREEN. O2 (1)1/2 "C, (1) #12 BLACK, (1) #12 WHITE, (1) #12 GREEN. O (1)2 -1/2 "C REVIEWED FOR COMPLIANCE WITH NPPA 70 NEC OCT 2 8 2010 BID ALTERNATE #2 (UPS ADDITION) City Of.Tukwlla • PROVIDE 'UPS CABINET' SCOPE IN ACCORDANCE WITH THILDING DIVISION EQUIPMENT LEGEND. • IN LIEU OF UPGRADING EXISTING ENCLOSED CIRCUIT BREAKER PROVIDE THE FOLLOWING: A. DEMOLISH EXISTING ENCLOSED CIRCUIT BREAKER LOCATED IN CT ROOM. B. REPLACE EXISTING 200A ENCLOSED CIRCUIT BREAKER (LOCATED IN BASEMENT ELECTRICAL ROOM ADJACENT TO CT TRANSFORMER) WITH NEW 90A, 3 —POLE CIRCUIT BREAKER. IF POSSIBLE, REUSE EXISTING ENCLOSURE. C. INSTALL NEW CT MAIN DISCONNECT FURNISHED BY GE. PROVIDE CONNECTION OF EXISTING FEEDER. IF MOUNTING LOCATION REQUIRES ADDITIONAL FEEDER LENGTH, PROVIDE PULL BOX WITH REMOVABLE COVER BELOW DISCONNECT. SPLICE AND EXTEND EXISTING FEEDER AS REQUIRED. Scale: 1/4" = 1' -0" 0 1 2 4 8 SHEET NOTES: 1 TELECOMMUNICATIONS VOICE /DATA SCOPE IS ROUGH —IN ONLY. FOR EACH WALL MOUNTED DEVICE SHOWN, PROVIDE THE FOLLOWING: • BACK BOX AND MUD —RING IN ACCORDANCE WITH REQUIREMENTS FROM OWNER'S VENDOR. • 3/4" EMPTY CONDUIT WITH PULL STRING AND BUSHED OPEN END, TURNED HORIZONTAL ABOVE CEILING AND ROUTED TO ABOVE AN ACCESSIBLE CEILING SPACE. THE SCOPE OF WORK OUTSIDE OF THIS CONTRACT (BY OWNER'S VENDOR) SHALL INCLUDE HORIZONTAL CABLING, FACE PLATES AND DEVICES, OPEN CABLING SUPPORTS, EQUIPMENT, AND CONNECTING HARDWARE. THE GENERAL CONTRACTOR SHALL COORDINATE CABLING INSTALLATION WITH THE OWNER'S VENDOR. . REFERENCE ARCHITECTURAL WALL ELEVATIONS FOR EXACT LOCATION OF WALL MOUNTED DEVICES. FLAG NOTES: EXTEND EXISTING CIRCUIT FROM ROOM TO FEED NEW RECEPTACLE(S) AS SHOWN. EXISTING WIREWAY. • PROVIDE NEW REMOVABLE COVERPLATE FOR ENTIRE LENGTH OF WIREWAY. • FOR PORTIONS OF THE WIREWAY WITH LARGE OPENINGS FROM THE PREVIOUS INSTALLATION, PROVIDE COVERPLATE, END PIECE, ETC. TO ENCLOSE THE WIREWAY. • FIELD VERIFY THE EXISTING INTERNAL DIVIDERS. PROVIDE OR REMOVE DIVIDERS AS REQUIRED TO MAINTAIN TWO DIVIDERS FOR THE ENTIRE LENGTH OF WI REWAY. GENERAL IMAGING RM NOTES: 1. PRIOR TO THE START OF INSTALLATION, SETUP A MEETING WITH THE GE HEALTHCARE PRODUCT REPRESENTATIVE TO LAYOUT EXACT RACEWAY, WALL BOX, AND CONDUIT PENETRATION LOCATIONS. • MICHAEL NOWAK, GE HEALTHCARE: 1- 888 - 470 -4853 MICHAEL.T.NOWAKOGE.COM 2. REFER TO GE HEALTHCARE EQUIPMENT DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF JUNCTION BOXES, DUCTS, SWITCHES, CIRCUIT BREAKERS, ETC. 3. PROVIDE ALL JUNCTION BOXES, CONDUIT, DUCT, DUCT DIVIDERS, SWITCHES, CIRCUIT BREAKERS, ETC. 4. CONDUIT AND DUCT RUNS SHALL HAVE SWEEP RADIUS BENDS. 5. CONDUIT AND DUCT RUNS ABOVE THE CEILING OR BELOW THE FINISHED FLOOR SHALL BE INSTALLED AS NEAR TO THE CEILING OR FLOOR AS POSSIBLE TO REDUCE RUN LENGTH. 6. DUCTWORK SHALL MEET THE FOLLOWING REQUIREMENTS: A. DUCTWORK SHALL BE METAL WITH DIVIDERS AND HAVE REMOVABLE, ACCESSIBLE COVERS. B. DUCTWORK SHALL BE CERTIFIED /RATED FOR ELECTRICAL POWER. C. DUCTWORK SHALL BE ELECTRICALLY AND MECHANICALLY BONDED TOGETHER. 5. PROVIDE A PULL CORD IN EACH EMPTY CONDUIT RUN. 6. PROVIDE 10' -0" WIRE PIGTAILS AT ALL JUNCTION POINTS. I8 REVISIONS in o co � o CT c<2 a) N Og c N w02co yEr) c?) LT "t c0 3 = _ 1 D ---....-_-_ 0 0 -1—' co V (DIN l) 4 • co cd L3). co co — N N CI) N ciTRr oFTU�wILA OCT KEY PLAN NOT TO SCALE 1.8 2010 PERMIT CENTER V PARTIAL FIRST FLOOR POWER & SYSTEMS PLAN (� Z Z_ a Q N— 2 O O z U W 2 w CL J W W Q Z W r>e- V (41; W d, U NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 TW DF 9 -10 -2010 HP -1 UNISTRUT FRAME F- 32,34,36 WP /.., F -30 30 1 U JJ N PARTIAL ROOF POWER PLAN Scale: 1/4" = 1' -0" 0 1 2 4 8 MECHANICAL EQUIPMENT SCHEDULE EQUIPMENT TAG VOLTAGE PHASE HP KW FLA MCA MOCP BRANCH CIRCUIT DISCONNECT NOTES RACEWAY PHASE N G SIZE FUSE HP -1 208 3 1 21 - 63.7 70 1-1/4" 3 #4 - 1#8 100 70 1 NOTES: PROVIDE DISCONNECT SWITCH. 1. SHEET NOTES: 1. ALL ELECTRICAL DEVICES (RECEPTACLES, SWITCHES, DISCONNECTS, ETC) ON ROOF SHALL BE WEATHERPROOF "IN USE" TYPE. IN ADDITION, ALL RECEPTACLES SHALL BE GFI TYPE RECEPTACLES. 2. CONDUIT EXPOSED ON ROOF SHALL BE: A. IMC CONDUIT WITH WATERTIGHT COMPRESSION FITTINGS. B. WIRING SHALL BE DERATED FOR POTENTIAL ROOF AMBIENT TEMPERATURE CONDITIONS. C. RUN PARALLEL TO BUILDING LINES AND NOT INTERFERING WITH ROOF WALK PATHWAYS. D. SUPPORTED ON AND STRAPPED TO 4 "X4 "X12" BLOCKING. BLOCK SHALL BE 8' -0" ON CENTER AND AT ALL BENDS. E. BLOCK SHALL BE PERMANENTLY ATTACHED TO ROOF PER ROOFING MANUFACTURER'S RECOMMENDATIONS AND WITHOUT VOIDING ANY ROOF WARRANTIES. 4. ROOF PENETRATIONS SHALL BE MADE PER ROOFING MANUFACTURER'S RECOMMENDATIONS AND SHALL NOT VOID THE ROOFING WARRANTY. FLAG NOTES: PROVIDE UNISTRUT FRAME FOR SUPPORT OF ELECTRICAL DISCONNECT AND CONVENIENCE RECEPTACLE. REVIEWED:FOH COMPLIANCE WITH NFPA 70 - NEC OCT 2 8 2010 �Y Ila B C' .Tukw UILDING DIVISION ELOO 8 l8 REVISIONS Z O 0- 2 Q Q 2 O maul ~ Q W uJ U W M JV 1 W a ce Q O Z morn cc cc a. J H W dd'' H ao U RECEIV u KEY PLAN CITY OFTULA NOT TO SCALE 1 3 2010 PERMIT CENTER PARTIAL ROOF POWER PLAN 8 N TECTURE V cc NAC NO HEI NO DRAWN CHECKED DATE 121 -10017 10113 TW DF 9 -10 -2010 U W r 3.2 PANEL SCHEDULE : 09/23/2010 (E) PANEL `F` PROJECT: HMC - Specialty Campus CT Upgrade CLASSIFICATION: NORMAL FED FROM: MOUNTING: SURFACE VOLTAGE: 208Y/120V 30, 4 -WIRE SECTION: 1 OF 1 MAINS: 225A MAIN LUGS ONLY NEUTRAL: 100% RATED TYPE: LOAD CENTER NOTE ITEM DESCRIPTION CKT NO. BREAKER LOAD (VA) 0 LOAD (VA) BREAKER CKT NO. ITEM DESCRIPTION NOTE AMPS POLE AMPS POLE 1 EQUIP - PHONE ROOM AC UNIT 1 20 2 * EXISTING 200A, 4 -WIRE FEEDER A 30 3 2 EQUIP - CT SCAN AIR AC UNIT 1 * EXISTING 400A, 4 -WIRE FEEDER 3 - - B - 4 - 1 EQUIP - TUBE SYSTEM AIR COMPRESSOR 5 20 3 C - - 6 - 7 - - A 20 3 8 EQUIP - TUBE SYSTEM BLOWER 1 - 9 B 10 1 EQUIP - TUBE SYSTEM AIR COOLER 11 20 1 C - - 12 - 1 UNKNOWN 13 20 • 1 A 20 1 14 UNKNOWN 1 1 UNKNOWN 15 20 1 B 20 1 16 REC - TELEST AF - PHONE ROOM DICTATION 1 1 UNKNOWN 17 20 1 C 20 1 18 REC - EAST WING 1 1 REC - LAB IG RECEPTACLES 19 20 1 A 30 2 20 EQUIP - AC UNIT R41149 1 1 REC - DATA CENTER CLOSET 21 20 1 B - - 22 - 1 REC - XRAY VIEWING ROOM 23 20 1 C 20 1 24 SPACE 25 20 1 A 20 1 26 REC - AC UNIT R4119 1 SPACE 27 20 1 B 20 1 28 SPACE SPACE 29 20 1 C 180 20 1 30 REC -HP -1 ROOF 2,3 SPACE 31 20 1 A 7649 70 3 32 EQUIP- HP -1 ROOF 2,3 SPACE 33 20 1 B 7649 - - 34 - SPACE 35 20 1 C 7649 - - 36 - SPACE 37 20 1 A 12729 200 3 38 < 30 DAY LOAD MONITORING> SPACE 39 20 1 B 12729 - - 40 - SPACE 41 20 1 C 12729 - - 42 - LOAD CALCULATIONS LOAD DESCRIPTION CONN. (VA) DEMAND FACTOR CALC. (VA) MISCELLANEOUS CONTINUOUS: EQUIPMENT & MISCELLANEOUS: LIGHTING: LARGEST MOTOR: MOTORS: RECEPTACLE: RECEPTACLES OVER 10kVA: ELECTRIC HEATING: TOTALS: 38187 125% 47734 - 100% - - 125% - - 125% - - 100% - 180 100% 180 - 50% - 22947 100% 22947 LOAD SUMMARY TOTAL CONNECTED LOAD AMPS PHASE A: 20,378 VA 170 A PHASE B: 20,378 VA 170 A PHASE C: 20,558 VA 171 A TOTAL CALCULATED LOAD: 70,861 VA TOTAL CALCULATED AMPS: 197 A 61,314 70,861 NOTES: 1. EXISTING CIRCUIT BREAKER. EXISTING LOAD TO REMAIN. 2. NEW CIRCUIT BREAKER. NEW LOAD. 3. PROVIDE CIRCUIT BREAKER WITH FAULT CURRENT RATING THAT MATCHES EXISTING CIRCUIT BREAKERS. 4. 5. HARGIS ENGINEERS, INC. 600 STEWART ST., SUITE 1000 SEATTLE, WA 98101 PH. (206) 448 -3376 FAX. (206) 448 -4450 PEAK DEMAND CALC WORKSHEET NEC 220 -87 AND WAC 296 - 46B- 901(15)(j) EXISTING PANEL F 1. RECORDED PEAK DEMAND ON DATE: SEPTEMBER 9, 2010 2. POWER FACTOR APPARENT PEAK DEMAND 3. NEC 220 -87 ADJUSTED PEAK DEMAND ADJUSTED PEAK DEMAND 4. SEASONAL ADJUSTMENT FACTOR * SEASONALLY ADJUSTED PEAK DEMAND 5. OCCUPANCY ADJUSTMENT FACTOR * OCCUPANCY ADJUSTED PEAK DEMAND 6. OTHER ADJUSTMENT FACTORS * ANNUAL PEAK DEMAND 7. NEW CALCULATED LOAD ADDED 33.50 KW / 0.860 (P.F.) 38.95 KVA X 1.25 = 48.69 KVA X 1.00 = 48.69 KVA x 1.00 48.69 KVA X 1.00 48.69 = 22.90 (NOTE 1) KVA KVA METERED DEMAND BASED CALCULATED LOAD: 71.59 KVA AMPERES AT 208V, 3 -PHASE 198.72 AMPS NOTE: SEE WAC 296 -46B- 901(15)0) FOR ADDITIONAL METERING REQUIREMENTS. * EXPLAIN HOW THE FACTOR WAS DERIVED FOR 30 -DAY DEMAND METERING SEASONAL - SEASONAL ADJUSTMENT FACTOR WAS COMPUTED BY APPLYING THE PERCENTAGE RATIO OF UTILITY METERED DEMAND LOAD AT THE TIME OF DESIGN & THE HIGHEST UTILITY METERED LOAD DURING THE 1 -YEAR PERIOD. OCCUPANCY - OCCUPANCY ADJUSTMENT FACTOR WAS DETERMINED TO BE 1.00 SINCE THE HOSPITAL IS EXPERIENCING NORMAL PATIENT VOLUMES. ALSO, A WORST CASE SEASONAL ADJUSTMENT WAS APPLIED. OTHER - OTHER CORRECTION FACTORS ARE NOT APPLICABLE. NOTE 1 - REFER TO PANEL F DEMAND CALCULATION WORKSHEETS FOR NEW LOAD DETAIL. AHU -5 /CD/ PANEL EQ 225A ROOF REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC OCT 2 8 2010 City of Tukwila BUILDING DIVISION FLOOR 4 PANEL EM 100A PANEL A 225A 1. NEW CT ELECTRICAL LOAD IS EQUAL OR LESS THAN THE EXISTING CT THAT IS BEING REPLACED IN THIS PROJECT. 2. REFERENCE SHEET E3.1 FOR SCOPE OF WORK WITHIN BOUNDARY. FLOOR 3 PANEL B 100A r PANEL H 225A CT CONNECTION PANEL J 40OA 20 NE) 200A/3 FLOOR 2 PANEL A 225A PANEL PANEL Al A2 225A 225A FLOOR 1 TO GENERATOR EDP #1 SWITCH #3, 60A/3 AF TO GENERATOR EDP #1 SWITCH #4, 200A/3 AF (60NE) ATS -3 - "LIFE SAFETY 1 BRANCH" I 100A #R50038 7 L J 480Y I 277V I I i 20s i I _ XFMR (200NE CT 150KVA 2000A BUS DUCT (60NE) K100NE) (200NE) -1 ATS -4 1 "CRITICAL 1 BRANCH" .1 200A #R50039 r- (20 NE) (200NE) (200NE) (200E) 30 -DAY LOAD MONITORING POINT (400NE) ATS -5 1 "EQUIPMENT SYSTEM" _ 1 400A #R50036 PANEL F 225A PANEL S 100A 400NE) LL N) 0 0 N L- 0 0 M ETER# 734333 600A BUS MAIN DISTRIBUTION PANEL 208Y/120V,30,4W 2000A TO SEATTLE CITY LIGHT TRANSFORMER VAULT SERVICE #2 SECTION VIII 208Y/120V,30,4W 2000A SECTION IX 208Y/120V,30,4W 2000A 600A BUS - - 0 SECTION X 208Y/120V,30,4W 2000A TO GENERATOR EDP #2 SWITCH #1, 400A/3 AF 30 -DAY LOAD MONITORING POINT BASEMENT (MAIN ELECTRICAL ROOM) CITYOF GGT 1 1010 PERMIT CENTER FLAG NOTES: PROVIDE FIELD VERIFICATION OF EXISTING FEEDER SIZE INCLUDING CONDUIT AND CONDUCTOR SIZES. UPDATE AS- BUILTS WITH UPDATED INFORMATION. I I I I I I I I I I J I I 1 1 1 I I I I I I I I I I I I I I 1 1 1 I I I I I I I I I i I X D 0 j © 2008 NAC Inc m R° o CT EQUIPMENT REPLACEMENT, ROOM 164 etygo4N - H A R G I S ,. . �' Hargis Engineers, Inc. 9� 9 A '° el 600 Stewart Street, Suite 1000 • o71* ARCHITECTURE ° �� Cn N CO 8 173 o I+IGHLINESPECIALTYCAMPUS Seattle, WA 98101 o o� o o \022/ 12844 MILITARY ROAD S TUKWILA, WASHINGTION H Z010 f1206.448.4450 Cn ONAL 1 w l hargis.biz In /lw.��� ��r��T� ��� nn.• •1,1/14 CIVTLI A % /KII ICI L•111TC 4 wnc I Cr Arm r I• /n nnwn• w A.7 I n. nnc ww4 wens I r.nnc wwn fn4-1 EXISTING; FEEDER SCHEDULE TAG QUANTITY OF SETS RACEWAY SIZE CONDUCTORS PHASE 1 NEUTRAL 1 GROUND 60NE * EXISTING 60A, 4 -WIRE FEEDER 100NE * EXISTING 100A, 4 -WIRE FEEDER 200E * EXISTING 200A, 3 -WIRE FEEDER 200NE * EXISTING 200A, 4 -WIRE FEEDER 400E * EXISTING 400A, 3 -WIRE FEEDER 400NE * EXISTING 400A, 4 -WIRE FEEDER POWER CO. DEMAND CALCULATION NEC 220 -87 AND WAC 296- 46B- 901(15)(j) EXISTING POWER COMPANY SERVICE #2, METER #734333 1. RECORDED PEAK DEMAND ON DATE: AUGUST 24, 2009 2. POWER FACTOR APPARENT PEAK DEMAND 3. NEC 220 -87 ADJUSTED PEAK DEMAND ADJUSTED PEAK DEMAND 4. SEASONAL ADJUSTMENT FACTOR * SEASONALLY ADJUSTED PEAK DEMAND 5. OCCUPANCY ADJUSTMENT FACTOR * OCCUPANCY ADJUSTED PEAK DEMAND 6. OTHER ADJUSTMENT FACTORS * ANNUAL PEAK DEMAND 7. NEW CALCULATED LOAD ADDED 127.68 KW / 0.860 (P.F.) 148.47 KVA X 1.25 185.58 KVA X 1.00 185.58 KVA x 1.00 185.58 KVA x 1.00 185.58 KVA 22.90 KVA (NOTE 1) METERED DEMAND BASED CALCULATED LOAD: 208.48 KVA AMPERES AT 208V, 3 -PHASE 578.69 AMPS NOTE: SEE WAC 296 -46B- 901(15)0) FOR ADDITIONAL METERING REQUIREMENTS. * EXPLAIN HOW THE FACTOR WAS DERIVED FOR 30 -DAY DEMAND METERING SEASONAL - SEASONAL ADJUSTMENT FACTOR WAS COMPUTED BY APPLYING THE PERCENTAGE RATIO OF UTILITY METERED DEMAND LOAD AT THE TIME OF DESIGN & THE HIGHEST UTILITY METERED LOAD DURING THE 1 -YEAR PERIOD. OCCUPANCY - OCCUPANCY ADJUSTMENT FACTOR WAS DETERMINED TO BE 1.00 SINCE THE HOSPITAL IS EXPERIENCING NORMAL PATIENT VOLUMES. ALSO, A WORST CASE SEASONAL ADJUSTMENT WAS APPLIED. OTHER - OTHER CORRECTION FACTORS ARE NOT APPLICABLE. NOTE 1 - REFER TO PANEL F DEMAND CALCULATION WORKSHEETS FOR NEW LOAD DETAIL. duo- 0818 PEAK DEMAND CALC WORKSHEET NEC 220 -87 AND WAC 296 - 46B- 901(15)(j) EXISTING MDP SECTION X 1. RECORDED PEAK DEMAND ON DATE: SEPTEMBER 3, 2010 2. POWER FACTOR APPARENT PEAK DEMAND 3. NEC 220 -87 ADJUSTED PEAK DEMAND ADJUSTED PEAK DEMAND 4. SEASONAL ADJUSTMENT FACTOR * SEASONALLY ADJUSTED PEAK DEMAND 5. OCCUPANCY ADJUSTMENT FACTOR * OCCUPANCY ADJUSTED PEAK DEMAND 6. OTHER ADJUSTMENT FACTORS * ANNUAL PEAK DEMAND 7. NEW CALCULATED LOAD ADDED 128.90 KW / 0.860 149.88 X 1.25 187.35 X 1.00 187.35 X 1.00 187.35 X 1.00 187.35 22.90 (NOTE 1) (P.F.) KVA KVA KVA KVA KVA KVA METERED DEMAND BASED CALCULATED LOAD: 210.25 KVA AMPERES AT 208V, 3 -PHASE 583.61 AMPS NOTE: SEE WAC 296 -46B- 901(15)0) FOR ADDITIONAL METERING REQUIREMENTS. * EXPLAIN HOW THE FACTOR WAS DERIVED FOR 30 -DAY DEMAND METERING SEASONAL - SEASONAL ADJUSTMENT FACTOR WAS COMPUTED BY APPLYING THE PERCENTAGE RATIO OF UTILITY METERED DEMAND LOAD AT THE TIME OF DESIGN & THE HIGHEST UTILITY METERED LOAD DURING THE 1 -YEAR PERIOD. OCCUPANCY - OCCUPANCY ADJUSTMENT FACTOR WAS DETERMINED TO BE 1.00 SINCE THE HOSPITAL IS EXPERIENCING NORMAL PATIENT VOLUMES. ALSO, A WORST CASE SEASONAL ADJUSTMENT WAS APPLIED. OTHER - OTHER CORRECTION FACTORS ARE NOT APPLICABLE. NOTE 1 - REFER TO PANEL F DEMAND CALCULATION WORKSHEETS FOR NEW LOAD DETAIL. ELECTRICAL ONE -LINE DIAGRAM 0 REVISIONS 0 0 z w 2 w U J 0 w 1- z w 2 0 0 w U NAC NO HEI NO DRAWN CHECKED DATE 2 V cc L.) CO N ce� ') N cci co rn 442 co co - cN N - 4- (i) 0 0 ce W co dam.. 121 -10017 10113 TW DF 9 -10 -2010 E 9.1