Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0828 - SABEY DATA CENTER
SABEY DATA CENTER 3355 S 120 PL EL1 0-0828 Parcel No.: Address: Tenant Name: Citylif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1023049082 3355 S 120 PL TUKW SABEY DATA CENTER ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -0828 11/15 /2010 06/06/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: LAURA RANNOW Address: 5614 7 AV S , SEATTLE WA 98108 Contractor: Name: VECA ELECTRIC CO INC Address: 5617 7TH AVE S , SEATTLE WA 98108 Contractor License No: VECAECI542MU Phone: 206 - 436 -5245 Phone: 206 860 -0231 Expiration Date: 10/31/2011 DESCRIPTION OF WORK: BUILD OUT OF DATA CENTER. FEEDERS TO STS'S & PDU'S WITH BRANCH CIRCUITRY REVISION #1: ADD 40 CIRCUITS FROM PDU'S FOR FUTURE EQUIPMENT INSTALL Value of Electrical Work: NRES: $515,365.00 Fees Collected: RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compile The granting of this p construction or the of this permit. Signature: Print Name: cOLQ $7,301.00 National Electrical Code Edition: 2008 Date: x- ned this permit and know the same to be true and correct. All provisions of law and ordinances wit whether specified herein or not. t does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ormance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back /,(J Date: /2 -J3- 2i0I0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0828 Printed: 12 -15 -2010 • 1 PERMIT CONDITIONS Permit No. EL 10 -0828 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-0828 Printed: 12 -15 -2010 Parcel No.: Address: Tenant Name: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1023049082 3355 S 120 PL TUKW SABEY DATA CENTER ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -0828 11/15/2010 05/14/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: LAURA RANNOW Address: 5614 7 AV S , SEATTLE WA 98108 Contractor: Name: VECA ELECTRIC CO INC Address: 5617 7TH AVE S , SEATTLE WA 98108 Contractor License No: VECAECI542MU Phone: 206 - 436 -5245 Phone: 206 860 -0231 Expiration Date: 10/31/2011 DESCRIPTION OF WORK: BUILD OUT OF DATA CENTER. FEEDERS TO STS'S & PDU'S WITH BRANCH CIRCUITRY Value of Electrical Work: NRES: $485,365.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Fees Collected: $6,967.25 National Electrical Code Edition: 2008 Permit Center Authorized Signature: — _ I Date: /J 7 I hereby certify that I have read and examined this p: t and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether . • ecified herein or not. The granting of thi ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t e • erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: / / '/ /v Print #4'5 Cplrl This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0828 Printed: 11 -15 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: Suite No: Tenant: 3355 S 120 PL TUKW SABEY DATA CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL10 -0828 ISSUED 10/15/2010 11/15/2010 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print a e / ee Date: //' /5 . /J doc: Cond -Elec EL10 -0828 Printed: 11 -15 -2010 elo • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. L1----t0— Q Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3355 South 120th Place, Tukwila , WA Tenant Name: Sabey Data Center Property Owners Name: Sabey Corporation King Co Assessor's Tax No.: 0)- 3Ol — 10O Suite Number: 5203B Floor: New Tenant: ❑ Yes ®..No Mailing Address: 12201 TUKWILA INTL BLVD 4TH FL Tukwila, WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Laura Rannow Mailing Address: 5614 7th Ave S Seattle, WA 98108 E -Mail Address: laura.rannow @veca.com Day Telephone: 206 -436 -5245 City State Fax Number: 206- 763 -0505 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA Electric Co. INC Mailing Address: 5614 7th Ave S Contact Person: Paul Masterjohn E -Mail Address: paul.masterjohn @veca.com Seattle WA City State Day Telephone: 206- 679 -5733 Fax Number: 206- 763 -0505 Contractor Registration Number: VECAECI542MU 98108 Zip Expiration Date: 10/31/10 Valuation of Project (contractor's bid price): $ 485,365 Scope of Work (please provide detailed information): Build out of data center. Feeders to STS's & PDU's with branch circuitry Will service be altered? © Yes ❑ No Type of Use: Commerical Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy in Seattle City Light H:\Applications\Forms - Applications On Line \4.2007 - Electrical Permit Application.doc bh Adding more than 50 amps? ® Yes ❑ No ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page l of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW. R OR ELECT ONTRACTOR: Signatur-. Print Name Laura Rannow Mailing Address: 5614 7th Ave S Date Application Accepted: 10.— 5- _ I Day Telephone: Seattle City Date: 206 - 436 -5245 WA State 98108 Zip Date Application Expires: r Staff Initials: H:\Applications\Fonns- Applications On Line \4 -2007 - Electrical Permit Application.doc bh v4( I Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: Status: Applied Date: Issue Date: EL10 -0828 ISSUED 10/15/2010 11/15/2010 Receipt No.: Initials: User ID: Payee: R10 -02504 JEM 1165 Payment Amount: Payment Date: Balance: $333.75 12/15/2010 09:20 AM $0.00 KURT J PREISSLER, VECA TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 087976 333.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 ELECTRICAL PLAN - NONRES 000.345.832.00.00 Total: $333.75 267.00 66.75 doc: Receiot -06 Printed: 12 -15 -2010 • • �J L4 wq� City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: EL10 -0828 Status: APPROVED Applied Date: 10/15/2010 Issue Date: Receipt No.: R10 -02303 Initials: TLS User ID: 1670 Payment Amount: $5,573.80 Payment Date: 11/15/2010 11:08 AM Balance: $0.00 Payee: VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 055170 5,573.80 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 5,573.80 Total: $5,573.80 doc: Receiot -06 Printed: 11 -15 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: EL10 -0828 Status: PENDING Applied Date: 10/15/2010 Issue Date: Receipt No.: R10 -02089 Initials: User ID: Payee: WER 1655 Payment Amount: $1,393.45 Payment Date: 10/15/2010 01:18 PM Balance: $5,573.80 TERRY MCCABE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 51517B ACCOUNT ITEM LIST: Description 1,393.45 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 1,393.45 Total: $1,393.45 doc: Receiot -06 Printed: 10 -15 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: 2/6 Address: _35, %20 pi..- Date Called: Special Instructions: Date Wanted: I am: P.m. Requester: Phone No: I Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Of1 qty ( 041 opt9 sc P� Inspector: 7i7 IA n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6-(0-68# PERMIT NO. CITY OF TUKWILA BUILDING DIVISION" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 ( 6 206)431 -3670 Project: „ , Type of Inspection: Address: 5 a / �� Date Called: Special Instructions: Date Wanted: 1 m a. : Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: ft-41 rrafl (J4 no43 Alfp pD.05 Inspector: Date: I0 /0 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 5/4. 11 1 cra, Type of Inspection: 101 Address: _5 • Co PG• Date Called: Special Instructions: Date Wanted: / �� ®� 6.1...„..n • p.m. Requester: /// Phone No: r Approved per applicable codes. • Ei Corrections required prior to approval. COMMENTS: � C L-I r 6,04 ,f Inspector: ( f Date: 2,/0 qt 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. FILE COPY Permit No. — Electric & Technologies SDC 52 PANEL SCHEDULES SUITE 52 -03B VECA Electric and Technologies, C Electrical Contractor ELtO4. 8z8 REVIEWED FOR COMPLIANCE WITH NFPA70 - NEC NOV 10 2010 City of Tukwila BUILDING DIVISION RECEIVED OCT 15 2010 PERMIT CENTER VECA Electric SWBD HDP52A ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION TA -52 LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 0.0 372.0 0.0 UPS 52-Al PRIMARY 1200 3 372 447 UPS 52-Al STATIC BYPASS 1200 3 - - AMP: 4000 MBP -52 -A1 MAINT BYPASS 1200 3 - - VOLTS: 277 0.0 0.0 372.0 0.0 UPS 52 -A2 PRIMARY 1200 3 372 447 480 UPS 52 -A2 STATIC BYPASS 1200 3 - - PHASE: 3 MBP -52 -A2 MAINT BYPASS 1200 3 - - WIRE: 3 0.0 0.0 372.0 0.0 UPS 52 -A3 PRIMARY 1200 3 372 447 BUS: CU UPS 52 -A3 STATIC BYPASS 1200 3 - - A.I.C.: 65K MBP -52 -A3 MAINT BYPASS 1200 3 - - M.L.O.: SPARE 800 3 - - MAIN CB: YES SPARE 800 3 - - FUSE: SPARE 800 3 - - FLUSH: 3.4 0.0 1377.5 0.0 M -52 -A MECHANICAL PANEL 3rd FLOOR 1600 3 1,381 1,661 SURF: YES 0.0 10.0 13.8 0.0 52A -H1 LIGHTING VIA 30 KVA 50 3 24 29 1.9 0.0 6.9 0.0 TRANSFORMER 52A -L1 50 3 9 11 TVSS 100 3 - - IG GND: r - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 5 III - LTG 10 - - EQP 2,514 - - HEAT - - - TOTAL 2,529 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 5 - - LTG 10 - - EQP 2,514 - - HEAT - - - TOTAL 2,529 - - FEEDER DEMAND - - kVA 2,532 TOTAL 2,529 3,042 AMPS 3,045 5 10 2,514 - MFG: SQ D CB: NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL TO GENERATOR POWER. • Project: SDC 52 10/11/10 VECA Electric 1 SWBD MBP -52 -A1 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52A LTG EQP HEAT DESCRIPTION AMP P kVA AMPS . 124.0 STS AB1 SUITE 52 -03 400 3 124 149 124.0 STS -AC1 SUITE 52 -03 400 3 124 149 AMP: 1200 124.0 STS -AD1 SUITE 52 -01 400 3 124 149 VOLTS: 277 STS -BA1 ALTERNATE FEED 400 3 - - 480 STS -CA1 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DA1 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: 1 - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT III - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 372 - MFG: SQ D CB: SQ D NOTE: 410 Project: SDC 52 10/11/10 VECA Electric SWBD MBP -52 -A2 I I ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52A LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 124.0 STS -AB2 SUITE 52 -01 400 3 124 149 124.0 STS -AC2 SUITE 52 -01 400 3 124 149 AMP: 1200 124.0 STS -AD2 SUITE 52 -01B 400 3 124 149 VOLTS: 277 STS -BA2 ALTERNATE FEED 400 3 - - 480 STS -CA2 ALTERNATE FEED 400 3 PHASE: 3 STS -DA2 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.LC.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT - • - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 - 372 - MFG: SQ D CB: SQ D NOTE: 110 Project: SDC 52 1 10/11/10 VECA Electric i SWBD MBP -52 -A3 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52A LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0 124.0 STS -AB3 SUITE 52-02 400 3 124 149 124.0 STS -AC3 SUITE 52 -01 400 3 124 149 AMP: 1200 124.0 STS -AD3 SUITE 52 -03 400 3 124 149 VOLTS: 277 STS -BA3 ALTERNATE FEED 400 3 - - 480 STS -CA3 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DA3 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 1 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT • - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - • - - TOTAL 372 - - FEEDER DEMAND - - • kVA 372 TOTAL 372 447 AMPS 447 - - 372 - MFG: SQ D CB: SQ D NOTE: 4110 Project: SDC 52 10/11/10 VECA Electric ; swsD M -52 -A 1 ROOM: 3RD FLOOR MECHANICAL ROOM LOAD DISTRIBUTION FROM: HDP -52A LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 40 17.5 AHU -52 -A3 UPS Room (Central Plant) 40 3 18 21 9.0 RF -52A UPS Room (Central Plant) 20 3 9 11 AMP: 1600 60.0 RF -5201A 2nd Floor (52 -01) 100 3 60 72 VOLTS: 277 60.0 RF -5203A 2nd Floor (52 -03) 100 3 60 72 480 28.0 ACU- 5201 -1 2nd Floor (52 -01) 60 13 28 34 PHASE: 3 19.0 25% of the Largest Motor 19 23 WIRE: 3 64.0 AHU-52-A1 3rd Floor (Central Plant) 125 _. 3 64 77 BUS: CU 64.0 AHU -52 -A2 3rd Floor (Central Plant) 125 3 64 77 A.I.C.: 65K 3.4 TRANSFORMER 52A -L3 3rd Floor (Central Plant) 50 3 3 4 M.L.O.: YES 243.0 CH -52 -A1 Roof (Central Plant) 350 3 243 292 MAIN CB: 243.0 CH -52 -A1 Roof (Central Plant) 350 3 243 292 FUSE: 243.0 CH -52 -A2 Roof (Central Plant) 350 3 243 292 FLUSH: 243.0 CH -52 -A2 Roof (Central Plant) 350 3 243 292 SURF: YES 24.0 CHP -52B Roof (Central Plant) 40 3 24 29 3 - - ' 3 - - IG GND: 3 - - 200% N: - - FD THRU: - - DBL LUG: - TOP: - - BTM: YES - - PANEL T.C.L. _ - - LOAD (kVA) - - RCPT 3.4 III _ LTG- - - EQP 1,318 - - HEAT - - - TOTAL 1,321 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG - ' - - EQP 1,318 - - HEAT - - - TOTAL 1,321 - - FEEDER DEMAND - - kVA 1,321 TOTAL 1,321 1,589 AMPS 1,589 3.4 - 1,318 - MFG: Square D CB: Square D NOTE: IIIProject: SDC 52 1 10/12/10 I 1 VECA Electric PANEL: 52A -H1 I ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP -52A A I B C LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.0 1 52 -03 DATA CENTER LIGHTS A 20 J 1 2.0 7.2 2.0 3 52 -01 DATA CENTER LIGHTS B 20 1 2.0 7.2 AMP: 100 2.0 5 52 -03 OFFICE LIGHTS C 20 1 2.0 7.2 VOLTS: 277 2.0 7 GENERATOR ROOM LIGHTS A 20 1 2.0 7.2 480 2.0 9 UPS ROOM LIGHTS B 20 1 2.0 7.2 PH: 3 2.0 11 52 -03A DATA CENTER LIGHTS C 20 1 2.0 7.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 y B 20 1 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: I 35 C 20 1 0.0 0.0 FD THRU: 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: 41 C 20 1 0.0 0.0 BTM: YES 3.0 2 SUMP PUMP 52A A 20 3 3.0 10.8 PANEL T.C.L. 3.0 4 SUMP PUMP 52A B 3.0 10.8 LOAD (kVA) 3.0 6 SUMP PUMP 52A C " " 3.0 10.8 RCPT 0.0 0.8 8 EXHAUST FAN 52A -1 A 20 3 0.8 2.9 LTG 12.0 0.8 10 EXHAUST FAN 52A -1 B 0.8 2.9 EQP 13.8 0.8 12 EXHAUST FAN 52A -1 C 0.8 2.9 HEAT 0.0 0.8 14 EXHAUST FAN 52A -2 A 20 3 0.8 2.9 1 0.8 16 EXHAUST FAN 52A -2 B 0.8 2.9 TOTAL 25.8 0.8 18 EXHAUST FAN 52A -2 C 0.8 2.9 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C .. 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 12.0 28 B 0.0 0.0 EQP 13.8 30 C " .' 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 25.8 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 28.8 42 C 20 1 0.0 0.0 AMPS 34.6 - A 0.0 0.0 - B II II 0.0 0.0 - C " " 0.0 0.0 0.0 12.0 13.8 0.0 KVA/AMPS: 8.6 31.0 8.6 31.0_ 8.6 31.0 Mfg/Type: Square D 0.0 4.0 4.6 0.0 A CB Type: 0.0 4.0 4.6 0.0 B Remarks: - 4.0 4.6 0.0 C 1 VECA Electric PANEL: 152A -L1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: 1 LOADS FROM: HDP 52A VIA XFMR 52A -L1 I A B C LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS T 1.5 1 GENERATOR A BLOCK HEATER A 20 2 1.5 12.5 1.5 3 GENERATOR A BLOCK HEATER B 1.5 12.5 AMP: 100 0.5 5 GENERATOR A BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52A CONTROLS B 20 1 1 0.5 4.2 PH: 3 0.5 11 HEAT TRACE C 20 1 0.5 4.2 WIRE: 4 1.0 13 AHU -52 -A3 MOTORS /ACUATORS A 20 1 1.0 8.3 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 7 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 ' 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG. 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.1 0.0 0.6 0.0 2 PANEL 52A -L2 A 50 3 1.7 14.0 PANEL T.C.L. 0.8 0.0 0.4 0.0 4 PANEL 52A -L2 B 1.2 10.0 LOAD (kVA) 0.0 0.4 0.0 6 PANEL 52A -L2 C " 0.4 3.3 RCPT 1.9 4 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 6.9 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 1 16 B 0.0 0.0 TOTAL 8.8 18 C 0.0 0.0 c 20 •A 0.0 0.0 FEEDER T.C.L. ti 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 1.9 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 6.9 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 8.8 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 8.8 42 C 0.0 0.0 AMPS 24.4 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 1.9 0.0 6.9 0.0 KVA/AMPS: 4.2 34.8 3.2 26.7 1.4 11.7 Mfg/Type: Square D 1.1 0.0 3.1 0.0 A CB Type: 0.8 0.0 2.4 0.0 B Remarks: - a0.0 1.4 0.0 C VECA Electric PANEL: 1 52A -L2 ROOM: 2ND FLOOR ELECTRICAL CLOSET FEED -THRU: LOADS FROM: PANEL 52A -L1 A B C ' 'T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 ACCO BUILDING CONTROLS A 20 1 0.8 6.7 I. 3 ACCO BUILDING CONTROLS B 20 1 0.8 6.7 AMP: 100 5 SPARE C 20 1 0.0 0.0 VOLTS: 120 0.3 7 SUITE 52 -03 CONVENIENCE OUTLETS A 20 1 0.3 2.5 208 0.3 9 SUITE 52 -03B CONVENIENCE OUTLETS B 20 1 0.3 2.5 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 _ 6 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 _ 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 0.4 2 SUITE 52 -01 CONVENIENCE OUTLETS A 20 1 0.4 3.3 PANEL T.C.L. 0.4 4 SUITE 52 -01 CONVENIENCE OUTLETS B 20 1 0.4 3.3 LOAD (kVA) 0.4 6 SUITE 52 -01 CONVENIENCE OUTLETS C 20 1 0.4 3.3 RCPT 2.2 0.2 8 CORRIDOR OUTLETS 52- 01/52 -02 A 20 1 0.2 1.5 • LTG 0.0 10 B 20 1 0.0 0.0 EQP 1.4 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 0.0 0.0 TOTAL 3.6 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 2.2 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 1.4 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 3.6 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 3.6 42 C 0.0 0.0 AMPS 9.9 - A 0.0 0.0 - B 0.0 0.0 - C " 0.0 0.0 2.2 0.0 1.4 0.0 KVA/AMPS: 1.7 14.0 1.5 12.5_ 0.4 3.3 Mfg/Type: Square D 1.1 0.0 0.6 0.0 A CB Type: 1.1 0.0 0.4 0.0 B Remarks: - 0.0 0.4 0.0 C VECA Electric PANEL: I52A -L3 ROOM: 3RD FLOOR MECHANICAL ROOM FEED -THRU: LOADS FROM: M -52A VIA XFMR 52A -L3 A B C 'T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 ROOF RECEPTACLE A 20 1 0.3 2.5 .8 3 HEAT TRACE B 20 1 0.8 6.7 AMP: 100 0.3 5 CONVENIENCE RECEPTACLE AT PANEL C 20 1 0.3 2.5 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG. 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.0 2 AHU 52A -1 CONTROLS /ACTUATORS A 20 1 1.0 8.3 PANEL T.C.L. 1.0 4 AHU 52A -2 CONTROLS /ACTUATORS B 20 1 1.0 8.3 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 3.4 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C ' 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 0.0 0.0 TOTAL 3.4 . 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) ' 24 C 0.0 0.0 RCPT 3.4 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 3.4 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 3.4 42 C 0.0 0.0 AMPS 9.4 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 3.4 0.0 0.0 0.0 KVA/AMPS:_ 1.3 10.8 1.8 15.0 0.3 2.5 Mfg/Type: Square D 1.3 0.0 0.0 0.0 A CB Type: 1.8 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 C VECA Electric 1 SWBD HDP52B ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION TB -52 LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0 372.0 UPS 52-B1 PRIMARY 1200 3 372 447 UPS 52 -B1 STATIC BYPASS 1200 3 - - AMP: 4000 MBP -52 -B1 MAINT BYPASS 1200 3 - - VOLTS: 277 372.0 UPS 52 -B2 PRIMARY 1200 3 372 447 480 UPS 52 -B2 STATIC BYPASS 1200 3 - - PHASE: 3 MBP -52 -B2 MAINT BYPASS 1200 3 - - WIRE: 3 372.0 _ UPS 52 -B3 PRIMARY 1200 3 372 447 BUS: CU UPS 52 -B3 STATIC BYPASS 1200 3 - - A.I.C.: 65K MBP -52 -B3 MAINT BYPASS 1200 3 - - M.L.O.: UPS 52 -B4 PRIMARY (FUTURE) 800 3 - - MAIN CB: YES UPS 52 -B4 STATIC BYPASS (FUTURE) 800 3 - - FUSE: MBP -52 -B4 MAINT BYPASS (FUTURE) 800 3 - - FLUSH: 2.9 0.0 1292.0 0.0 M -52 -B MECHANICAL PANEL 3rd FLOOR 1600 3 1,295 1,558 SURF: YES 0.0 10.0 4.8 0.0 52B -H1 LIGHTING VIA 30 KVA 50 3 15 18 TVSS 100 3 - - IG GND: 74.0 89.0 293.0 COMMON AREA LOAD 1200 3 456 548 200% N: 1.9 0.0 4.5 0.0 TRANSFORMER 52B -L1 50 3 6 8 FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) 411 - - RCPT 79 - LTG 99 - - EQP 2,710 - - HEAT - 1 - - TOTAL 2,888 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 79 - - LTG 99 - - EQP 2,710 - - HEAT - - - TOTAL 2,888 - - FEEDER DEMAND - - kVA 2,878 TOTAL 2,888 3,474 AMPS 3,462 79 99 2,710 - MFG: SQ D CB: NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL TO GENERATOR POWER. • Project: SDC 52 10/11/10 VECA Electric I SWBD MBP -52 -B1 1 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52B T LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 124.0 STS -BA1 SUITE 52 -03 400 3 124 149 124.0 STS -BC1 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 STS -BD1 SUITE 52 -03B 400 3 124 149 VOLTS: 277 STS -AB1 ALTERNATE FEED 400 3 - - 480 STS -CB1 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DB1 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: ' - - MAIN CB: YES - - FUSE: FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - RCPT - III - LTG - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 • - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 - - 372 - MFG: SQ D CB: SQ D NOTE: • Project: ISDC 52 10/11/10 VECA Electric 1 SWBD MBP -52 -B2 1 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52B LTG EQP HEAT DESCRIPTION AMP P kVA AMPS a 124.0 STS -BA2 SUITE 52 -01 400 3 124 149 124.0 STS -BC2 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 STS -BD2 SUITE 52 -01B 400 3 124 149 VOLTS: 277 STS -AB2 ALTERNATE FEED 400 3 - - 480 STS -CB2 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DB2 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT III LTG- - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - . - kVA 372 TOTAL 372 447 AMPS 447 - - 372 - MFG: SQ D CB: SQ D NOTE: IIII Project: SDC 52 1 10/11/10 VECA Electric 1 SWBD MBP -52 -B3 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52B LTG EQP HEAT _ DESCRIPTION AMP P kVA AMPS 0 124.0 STS -BA3 SUITE 52 -02 400 3 124 149 124.0 STS -BC3 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 STS -BD3 SUITE 52 -03B 400 3 124 149 VOLTS: 277 -AB3 ALTERNATE FEED 400 3 - - 480 _STS STS -CB3 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DB3 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) III - - RCPT - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - kVA 372 TOTAL 372 447 AMPS 447 372 - MFG: SQ D CB: SQ D NOTE: • Project:ISDC 52 10/11/10 VECA Electric I SWBD M -52 -B ROOM: 3RD FLOOR MECHANICAL ROOM LOAD DISTRIBUTION FROM: HDP -52B LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 17.5 AHU -52 -B2 North UPS Room (Central Plant) 40 3 18 21 9.0 RF -52B UPS Room (Central Plant) 20 3 9 11 AMP: 1600 60.0 RF -5203B 2nd Floor (52 -03) 100 3 60 72 VOLTS: 277 60.0 RF -5201B 2nd Floor (52 -01) 100 3 60 72 480 2.5 EF- 5201 -1 2nd Floor (52 -01) 20 3 3 3 PHASE: 3 128.0 AHU -52 -B1 3rd Floor (Central Plant) 225 3 128 154 WIRE: 3 2.9 TRANSFORMER 52B -L3 3rd Floor (Central Plant) 50 3 3 3 BUS: CU 243.0 CH -52 -B1 Roof (Central Plant) 350 3 243 292 A.I.C.: 65K 243.0 . CH -52 -B1 Roof (Central Plant) 350 3 243 292 M.L.O.: YES 243.0 CH -52 -B2 Roof (Central Plant) 350 3 243 292 MAIN CB: 243.0 CH -52 -B2 Roof (Central Plant) 350 3 243 292 FUSE: 24.0 CHP -52B Roof (Central Plant) 40 3 24 29 FLUSH: 19.0 25% of the Largest Motor 19 23 SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) _ - RCPT 2.9 III - LTG � - - EQP 1,292 - - HEAT - - - TOTAL 1,295 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG - - - EQP 1,292 - - HEAT - - - TOTAL 1,295 - - FEEDER DEMAND - - kVA 1,295 TOTAL 1,295 1,558 AMPS 1,558 2.9 - 1,292 - MFG: SQ D CB: NOTE: IIIProject: SDC 52 1 10/11/10 VECA Electric PANEL: I52B -H1 ROOM: FUTURE FEED -THRU: LOADS 110 FROM: HDP -52B I A B C T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 2.0 1 SUITE 52 -03 DATA CENTER LIGHTS A 20 1 2.0 7.2 2.0 3 SUITE 52 -02 DATA CENTER LIGHTS B 20 1 2.0 7.2 AMP: 100 2.0 5 SUITE 52 -03 OFFICE LIGHTS C 20 1 .2.0 7.2 VOLTS: 277 2.0 7 GENERATOR ROOM LIGHTS A 20 1 2.0 7.2 480 2.0 9 UPS ROOM LIGHTS B 20 1 2.0 7.2 PH: 3 2.0 11 SUITE 52 -03B DATA CENTER LIGHTS C 20 1 2.0 7.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 0.0 8 A 20 1 0.0 0.0 LTG 12.0 10 B 20 1 0.0 0.0 EQP 4.8 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 i 16 B 0.0 0.0 TOTAL 16.8 18 C " " 0.0 0.0 c 0.8 20 EXHAUST FAN 52B -1 A 20 3 0.8 2.9 FEEDER T.C.L. fi 0.8 22 EXHAUST FAN 52B -1 B 0.8 2.9 LOAD (kVA) 0.8 24 EXHAUST FAN 52B -1 C " " 0.8 2.9 RCPT 0.0 0.8 26 EXHAUST FAN 52B -2 A 20 3 0.8 2.9 LTG 12.0 0.8 28 EXHAUST FAN 52B -2 B 0.8 2.9 EQP 4.8 0.8 30 EXHAUST FAN 52B -2 C " " 0.8 2.9 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 16.8 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 19.8 42 C 20 1 0.0 0.0 AMPS 23.8 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 0.0 12.0 4.8 0.0 KVA/AMPS: 5.6 20.2 5.6 20.2 5.6 20.2 Mfg/Type: 0.0 4.0 1.6 0.0 A CB Type: 0.0 4.0 1.6 0.0 B Remarks: - S4.0 1.6 0.0 C I 1 1 VELA Electric PANEL: 152B-L1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP -52B VIA XFMR 52B -L1 A B C 0 LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.5 1 GENERATOR B BLOCK HEATER A 20 1 1.5 12.5 1.5 3 GENERATOR B BLOCK HEATER B 20 1 1.5 12.5 AMP: 100 0.5 5 GENERATOR B BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 1 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52B CONTROLS B 20 1 0.5 4.2 PH: 3 0.5 11 HEAT TRACE C 20 1 0.5 4.2 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 , 1 _ 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: _ 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 0.8 2 PANEL 52B -L2 A 20 1 0.8 6.7 PANEL T.C.L. 0.8 4 PANEL 52B -L2 B 20 1 0.8 6.7 LOAD (kVA) 6 PANEL 52B-L2 C 20 1 0.3 2.5 RCPT 1.9 46 8 A ,. 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 4.5 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B " 0.0 0.0 TOTAL 6.4 18 C " 0.0 0.0 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 0 C " 0.0 0.0 RCPT 1.9 26 A 30 3 0.0 0.0 LTG 0.0 28 8 0.0 0.0 EQP 4.5 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 6.4 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 6.4 42 C 20 1 0.0 0.0 AMPS 17.8 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 1.9 0.0 4.5 0.0 KVA/AMPS: 2.3 19.2 2.8_ 23.3 1.3 10.8 Mfg/Type: Square D 0.8 0.0 1.5 0.0 A CB Type: 0.0 2.0 0.0 B Remarks: - 0.0 1.0 0.0 C VECA Electric PANEL: I52B -L2I ROOM: FUTURE FEED THRU: 1 LOADS FROM: PANEL 52B -L1 A B C LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 ACCO BUILDING CONTROLS A 20 1 0.8 6.7 �.: 3 ACCO BUILDING CONTROLS B 20 1 0.8 6.7 AMP: 100 5 SPARE C 20 1 0.0 0.0 VOLTS: 120 0.3 7 SUITE 52 -03 CONVENIENCE OUTLETS A 20 1 0.3 2.5 208 0.3 9 SUITE 52 -03B CONVENIENCE OUTLETS B 20 1 0.3 2.5 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG. 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.2 8 A 20 .1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B 0.0 0.0 TOTAL 2.2 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C " 0.0 0.0 RCPT 2.2 26 A 30 3 0.0 0.0 LTG 0.0 28 B " 0.0 0.0 EQP 0.0 30 C " " 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 2.2 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 2.2 42 C 20 1 0.0 0.0 AMPS 6.1 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 2.2 0.0 0.0 0.0 KVA/AMPS: 1.1 9.2 1.1 9.2 0.0 0.0 Mfg/Type: Square D 1.1 0.0 0.0 0.0 A CB Type: ' 1.1 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 C VECA Electric PANEL: I552B -L3 I ROOM: I3RD FLOOR MECHANICAL ROOM FEED -THRU: LOADS FROM: M -52B VIA XFMR 52B -L3 I A B C LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 ROOF RECEPTACLE A 20 1 0.8 6.7 '.8 3 HEAT TRACE B 20 1 0.8 6.7 AMP: 100 0.3 • 5 CONVENIENCE RECEPTACLE AT PANEL C 20 1 0.3 2.5 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 1.0 2 AHU 52 -B1 CONTROLS /ACTUATORS A 20 1 1.0 8.3 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.9 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B 0.0 0.0 TOTAL 2.9 18 C " " 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B " 0.0 0.0 LOAD (kVA) 24 C " 0.0 0.0 RCPT 2.9 26 A 30 3 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 . 34 B 0.0 0.0 TOTAL 2.9 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 2.9 42 C 20 1 0.0 0.0 AMPS 8.0 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 2.9 0.0 0.0 0.0 KVA/AMPS: 1.8 15.0 0.8 6.7 0.3 2.5 Mfg/Type: Square D 1.8 0.0 0.0 0.0 A CB Type: 0.8 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 C VECA Electric 1 SWBD HDP -52C ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION HVS C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0 372.0 UPS 52 -C1 PRIMARY 1200 3 372 447 UPS 52 -C1 STATIC BYPASS 1200 3 - - AMP: 4000 MCP -52 -C1 MAINT BYPASS 1200 3 - - VOLTS: 277 372.0 UPS 52 -C2 PRIMARY 1200 3 372 447 480 UPS 52 -C2 STATIC BYPASS 1200 3 - - PHASE: 3 MCP -52 -C2 MAINT BYPASS 1200 3 - - WIRE: 3 372.0 UPS 52 -C3 PRIMARY 1200 3 372 447 BUS: CU UPS 52 -C3 STATIC BYPASS 1200 3 - - A.I.C.: 65K MCP -52 -C3 MAINT BYPASS 1200 3 - - M.L.O.: 9.0 RF -52C 20 3 9 11 MAIN CB: YES 17.5 AHU -52C3 60 3 18 21 FUSE: - FLUSH: 2.2 0.0 1323.0 M52 -C MECH 1600 3 1,325 1,594 SURF: YES 0.0 2.0 4.8 52C -H1 50 3 7 8 1.0 0.0 5.0 XFMR 52C SERVING 52C -L1 50 3 6 7 - - IG GND: 9.0 RF -52D (TEMPORARY FEED) 9 11 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 3 • - - LTG 2 - - EQP 2,484 - - HEAT - - - TOTAL 2,490 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG 2 - - EQP 2,484 - - HEAT - - - TOTAL 2,490 - - FEEDER DEMAND - - kVA 2,490 TOTAL 2,490 2,994 AMPS 2,995 3 2 2,484 - MFG: SQ D CB: NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL Feeder T.C.L. is printed here horizontally TO GENERATOR POWER. to allow a block "paste -link" to the Distribution" columns of a sub - :Load feed panel or switchboard. I I 1 Project: 1SDC 52 10/11/10' 1 1 1 VECA Electric 1 SWBD MBP -52 -C1 1 1 I ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 124.0 STS -CA1 SUITE 52 -03 400 3 124 149 124.0 STS -CB1 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 STS -CD1 SUITE 52 -02B 400 3 124 149 VOLTS: 277 STS -AC1 ALTERNATE FEED 400 3 - - 480 STS -BC1 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DC1 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES • - - IG GND: - - 200% N: - - FD THRU: , - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT III LTG- - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. • - - LOAD' (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 • - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 - _ - 372 - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub - feed panel or switchboard. I j J Project: SDC 52 10/11/10 VELA Electric 1 SWBD MBP -52 -C2 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS . 124.0 STS -CA2 SUITE 52 -01 400 3 124 149 124.0 STS -CB2 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 STS -CD2 SUITE 52 -02B 400 3 124 149 VOLTS: 277 STS -AC2 ALTERNATE FEED 400 3 - - 480 STS -BC2 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DC2 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT III - LTG - - - EQP 372 - -' HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 372 _ - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub- •feed panel or switchboard. I I I Project: SDC 52 10/11/10 VECA Electric I SWBD MBP -52 -C3 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS • 124.0 STS -CA3 SUITE 52 -01 400 3 124 149 124.0 STS -CB3 SUITE 52 -02 400 3 124 149 AMP: 1200 124.0 y STS -CD3 SUITE 52 -03B 400 3 124 149 VOLTS: 277 STS -AC3 ALTERNATE FEED 400 3 - - 480 STS -BC3 ALTERNATE FEED 400 3 - - PHASE: 3 STS -DC3 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT • - - LTG - - - EQP 372 - - HEAT. - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 372 - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the Distribution" columns of a sub - :Load feed panel or switchboard. I I I Project: SDC 52 10/11/10 VECA Electric SWBD M -52C ROOM: 3RD FLOOR MECHANICAL ROOM LOAD DISTRIBUTION FROM: HDP -52C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 60.0 RF -5201C 2nd Floor 100 3 60 72 60.0 RF -5202C 2nd Floor 100 3 60 72 AMP: 1600 60.0 RF -5203C 2nd Floor 100 3 60 72 VOLTS: 277 243.0 CH -52 -C1 Roof 350 3 243 292 480 243.0 CH -52 -C1 Roof 350 3 243 292 PHASE: 3 243.0 CH -52 -C2 Roof 350 3 243 292 WIRE: 3 243.0 CH -52 -C2 Roof 350 3 243 292 BUS: CU 24.0 CHP -52BC Roof 40 3 24 29 A.I.C.: 65K 64.0 AHU -52 -C1 3rd Floor 150 3 64 77 M.L.O.: YES 64.0 AHU -52 -C2 3rd Floor 150 3 64 77 MAIN CB: 2.2 0.0 0.0 0.0 Transformer 52C -L2 3rd Floor 50 3 2 3 FUSE: 19.0 25% of the Largest Motor 40 3 19 23 FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES _ - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 2 III LTG - - - EQP 1,323 - - HEAT - - - TOTAL 1,325 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 2 - - LTG - - - EQP 1,323 - - HEAT - - - TOTAL 1,325 - - FEEDER DEMAND - - kVA 1,325 TOTAL 1,325 1,594 AMPS 1,594 2 - 1,323 - MFG: SQ D CB: NOTE: 410 Project: SDC 52 1 10/12/10 1 VECA Electric PANEL: 152C -H1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP -52C A B C LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 277 7 A 20 1 0.0 0.0 480 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 .. BUS: CU 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU: 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: 41 C 20 1 0.0 0.0 BTM: YES 2.0 2 GENERATOR ROOM LIGHTS A 20 3 2.0 7.2 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT 0.0 0.8 8 EXHAUST FAN 52C -1 A 20 3 0.8 2.9 LTG 2.0 0.8 10 EXHAUST FAN 52C -1 B 0.8 2.9 EQP 4.8 0.8 12 EXHAUST FAN 52C -1 C " n 0.8 2.9 HEAT 0.0 0.8 14 EXHAUST FAN 52D -1 TEMPORARY FEED A 20 3 0.8 2.9 1 0.8 16 EXHAUST FAN 52D -1 TEMPORARY FEED B " " 0.8 2.9 TOTAL 6.8 0.8 18 EXHAUST FAN 52D -1 TEMPORARY FEED C " 0.8 2.9 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C " " 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 2.0 28 B 0.0 0.0 EQP 4.8 1 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 6.8 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 7.3 42 C 20 1 0.0 0.0 AMPS 8.8 - A 0.0 0.0 - B 0.0 0.0 - c " " 0.0 0.0 0.0 2.0 4.8 0.0 KVA/AMPS: 3.6 13.0 1.6 5.8 1.6 5.8 Mfg/Type: Square D 0.0 2.0 1.6 0.0 A CB Type: s.0 0.0 1.6 0.0 B Remarks: - 0.0 1.6 0.0 C SDC 52 VECA Electric PANEL: 152C -L1 I ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP 52C VIA XFMR 52C A B C "T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.5 1 GENERATOR C BLOCK HEATER A 20 2 1.5 12.5 1.5 3 GENERATOR C BLOCK HEATER B " 1.5 12.5 AMP: 100 0.5 5 GENERATOR C BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52C CONTROLS B 20 1 0.5 4.2 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 1.0 13 AHU -52 -C3 MOTORS /ACUATORS A 20 1 1.0 8.3 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG. 1.0 39 GENERATOR ROOM RECEPTACLES B 20 1 1.0 8.3 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 50 3 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 0.0 0.0 RCPT 1.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 5.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 1 16 B 0.0 0.0 TOTAL 6.0 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 1.0 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 5.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 6.0 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 6.0 42 C 0.0 0.0 AMPS 16.7 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 1.0 0.0 5.0 0.0 KVA/AMPS: 2.5 20.8 3.0 25.0 0.5 4.2 Mfg/Type: Square D 0.0 0.0 2.5 0.0 A CB Type: 1.0 0.0 2.0 0.0 B Remarks: - 0.0 0.5 0.0 C SDC 52 I 1 VECA Electric PANEL: 52C -L2 I ROOM: 3RD FLOOR MECHANICAL ROOM FEED -THRU: LOADS FROM: M52C VIA XFMR 1 A B C T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 RECEPTACLE ON ROOF A 20 1 0.2 1.7 .0 3 AHU -52 -C1 MOTORS /ACUATORS B 20 1 1.0 8.3 AMP: 100 1.0 5 AHU -52 -C1 MOTORS /ACUATORS C 20 1 1.0 8.3 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.2 S 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 i 16 B 0.0 0.0 TOTAL 2.2 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. h 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 2.2 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 2.2 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 2.2 42 C 0.0 0.0 AMPS 6.1 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 2.2 0.0 0.0 0.0 KVA/AMPS: 0.2 1.7 1.0_ 8.3 1.0 8.3 Mfg/Type: Square D 0.2 0.0 0.0 0.0 A CB Type: 1.0 0.0 0.0 0.0 B Remarks: - in 0.0 0.0 0.0 C SDC 52 VECA Electric SWBD HDP52D ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: UNIT SUBSTATION TB-52 T LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 372.0 UPS 52 -D1 PRIMARY 1200 3 372 447 UPS 52 -D1 STATIC BYPASS 1200 3 - - AMP: 4000 MDP -52 -D1 MAINT BYPASS 1200 3 - - VOLTS: 277 . 372.0 UPS 52 -D2 PRIMARY 1200 3 372 447 480 UPS 52 -D2 STATIC BYPASS 1200 3 - - PHASE: 3 MDP -52 -D2 MAINT BYPASS 1200 3 - - WIRE: 3 372.0 UPS 52 -D3 PRIMARY 1200 3 372 447 BUS: CU UPS 52 -D3 STATIC BYPASS 1200 3 - - A.I.C.: 65K MDP -52 -D3 MAINT BYPASS 1200 3 - - M.L.O.: SPARE 800 3 - - MAIN CB: YES SPARE 800 3 - - FUSE: SPARE 800 3 - - FLUSH: . 2.2 0.0 1323.0 0.0 M -52D MECH 1600 3 1,325 1,594 SURF: YES 0.0 2.0 2.4 0.0 52D -H1 LIGHTING VIA 30 KVA (FUTURE) 50 3 4 5 1.0 0.0 5.0 0.0 52D -L1 RECPT VIA 30 KVA (FUTURE) 50 3 6 7 TVSS 100 3 - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - PANEL T.C.L. - - LOAD (kVA) - - RCPT 3 III LTG 2 - - EQP 2,446 - - HEAT - - - TOTAL 2,452 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 3 - - LTG 2 - - EQP 2,446 - - HEAT - - - TOTAL 2,452 - - FEEDER DEMAND - - kVA 2,452 TOTAL 2,452 2,949 AMPS 2,949 3 2 2,446 - MFG: SQ D CB: NOTE: SWITCHBOARD HAS DUAL INPUT BREAKERS WITH AUTOMATIC TRANSFER FROM NORMAL Feeder T.C.L. is printed here horizontally TO GENERATOR POWER. to allow a block "paste -link" to the "Load Distribution" columns of a sub- •feed panel or switchboard. I I I _Project: SDC 52 10/11/10 VECA Electric I SWBD MBP -52 -D1 I ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52D T LTG EQP HEAT DESCRIPTION AMP P kVA AMPS 0 124.0 STS -DA1 SUITE 52 -01 400 3 124 149 124.0 STS -DB1 SUITE 52 -03B 400 3 124 149 AMP: 1200 124.0 STS -DC1 SUITE 52 -02B 400 3 124 149 VOLTS: 277 STS -AD1 ALTERNATE FEED 400 3 - - 480 STS -BD1 ALTERNATE FEED 400 3 - - PHASE: 3 STS -CD1 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 1111 - LTG - - - EQP 372 - - HEAT - - \- TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - • - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 - - 372 - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the "Load Distribution" columns of a sub- •feed panel or switchboard. I I 1 Project: ISDC 52 1 10/11/10 VECA Electric I_SWBD MBP -52 -D2 ROOM:JSDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52D LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 124.0 STS -DA2 SUITE 52 -01B 400 3 124 149 124.0 STS -DB2 SUITE 52 -01B 400 3 124 149 AMP: 1200 124.0 STS -DC2 SUITE 52 -02B 400 3 124 149 VOLTS: 277 STS -AD2 ALTERNATE FEED 400 3 - - 480 STS -BD2 ALTERNATE FEED 400 3 - - PHASE: 3 • STS -CD2 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - RCPT - • - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 - 372 - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the °Load Distribution" columns of a sub- •feed panel or switchboard. I I I Project: SDC 52 10/11/10 1 VELA Electric 1 SWBDJMBP -52 -D3 ROOM: SDC 52 MAIN ELEC ROOM LOAD DISTRIBUTION FROM: HDP -52D . LTG EQP HEAT DESCRIPTION AMP P kVA AMPS Or 124.0 STS -DA3 SUITE 52 -03 400 3 124 149 124.0 STS -DB3 SUITE 52 -03B 400 3 124 149 AMP: 1200 124.0 STS -DC3 SUITE 52 -03B 400 3 124 149 VOLTS: 277 STS-AD3 ALTERNATE FEED 400 3 - - 480 STS -BD3 ALTERNATE FEED 400 3 - - PHASE: 3 STS -CD3 ALTERNATE FEED 400 3 - - WIRE: 3 - - BUS: CU - - A.I.C.: 65K I. - - M.L.O.: - - MAIN CB: YES - - FUSE: - - FLUSH: _ - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT • - - LTG- - - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER T.C.L. - LOAD (kVA) - - RCPT - - - LTG - -. - EQP 372 - - HEAT - - - TOTAL 372 - - FEEDER DEMAND - - kVA 372 TOTAL 372 447 AMPS 447 372 - MFG: SQ D CB: SQ D NOTE: Feeder T.C.L. is printed here horizontally to allow a block "paste -link" to the Distribution" columns of a sub - :Load feed panel or switchboard. I I I Project: SDC 52 1 1 1 10/11/10 I VECA Electric I SWBD M -52D ROOM: 3RD FLOOR MECHANICAL ROOM TM 601094 LOAD DISTRIBUTION FROM: HDP -52C LTG EQP HEAT DESCRIPTION AMP P kVA AMPS OT 60.0 RF-5201D 2nd Floor 100 3 60 72 60.0 RF -5202D 2nd Floor 100 3 60 72 AMP: 1600 60.0 RF -5203D 2nd Floor 100 3 60 72 VOLTS: 277 243.0 CH -52 -D1 Roof 350 3 243 292 480 243.0 CH -52 -D1 Roof 350 3 243 292 PHASE: 3 243.0 CH -52 -D2 Roof 350 3 243 292 WIRE: 3 243.0 CH -52 -C2 Roof 350 3 243 292 BUS: CU 24.0 CHP -52D Roof 40 3 24 29 A.I.C.: 65K 64.0 AHU -52 -D1 3rd Floor 150 3 64 77 M.L.O.: YES 64.0 AHU -52 -D2 3rd Floor 150 3 64 77 MAIN CB: 2.2 0.0 0.0 0.0 Transformer 52D -L2 3rd Floor 50 3 2 3 FUSE: 19.0 25% of the Largest Motor 40 3 19 23 FLUSH: - - SURF: YES - - IG GND: - - 200% N: - - FD THRU: - - DBL LUG: - - TOP: - - BTM: YES - - PANEL T.C.L. - - LOAD (kVA) - - RCPT 2 III LTG - - - EQP 1,323 - - HEAT - - - TOTAL 1,325 - - FEEDER T.C.L. - - LOAD (kVA) - - RCPT 2 - - LTG - - - EQP 1,323 - - HEAT - - - TOTAL 1,325 - - FEEDER DEMAND - - kVA 1,325 TOTAL 1,325 1,594 AMPS 1,594 2 - 1,323 - MFG: SQ D CB: NOTE: 41110 I Project: 1 SDC 52 ( 10/11/10 1 VECA Electric PANEL: 152D -H1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: LOADS FROM: HDP -52D A B C T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 A 20 1 0.0 0.0 3 B 20 1 0.0 0.0 AMP: 100 5 C 20 1 0.0 0.0 VOLTS: 277 7 A 20 1 0.0 0.0 480 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: CU , 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: 19 A 20 1 0.0 0.0 MCB: YES 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND 33 B 20 1 0.0 0.0 200% N: I 35 C 20 1 0.0 0.0 FD THRU: 37 A 20 1 0.0 0.0 DBL LUG. 39 B 20 1 0.0 0.0 TOP: 41 C 20 1 0.0 0.0 BTM: YES 2.0 2 GENERATOR ROOM LIGHTS A 20 3 2.0 7.2 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C 0.0 0.0 RCPT 0.0 1111 0.8 8 EXHAUST FAN 52D -1 A 20 3 0.8 2.9 LTG 2.0 0.8 10 EXHAUST FAN 52D -1 B 0.8 2.9 EQP 2.4 0.8 12 EXHAUST FAN 52 -1 C " 0.8 2.9 HEAT 0.0 14 A 20 3 0.0 0.0 1 16 B 0.0 0.0 TOTAL 4.4 18 C 0.0 0.0 c 20 A 30 3 0.0 0.0 FEEDER T.C.L. fi 22 B 0.0 0.0 LOAD (kVA) 24 C " 0.0 0.0 RCPT 0.0 26 A 30 3 0.0 0.0 LTG 2.0 28 B 0.0 0.0 EQP 2.4 30 C " 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 4.4 36 C 0.0 0.0 LG MTR 38 A 30 2 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 4.9 42 C 20 1 0.0 0.0 AMPS 5.9 - A 0.0 0.0 - B 0.0 0.0 - C " " 0.0 0.0 0.0 2.0 2.4 0.0 KVA/AMPS: 2.8 10.1 0.8 2.9 0.8 2.9 Mfg/Type: Square D 0.0 2.0 0.8 0.0 A CB Type: 0.0 0.0 0.8 0.0 B Remarks: - - 0.0 0.8 0.0 C SDC 52 I VECA Electric PANEL: 52D -L1 ROOM: SDC 52 GENERATOR ROOM FEED -THRU: _ LOADS FROM: HDP 52D VIA XFMR 52D A B C r -' LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1.5 1 GENERATOR D BLOCK HEATER A 20 2 1.5 12.5 1.5 3 GENERATOR D BLOCK HEATER B " 1.5 12.5 AMP: 100 _ 0.5 5 GENERATOR D BATTERY CHARGER C 20 1 0.5 4.2 VOLTS: 120 7 SPARE A 20 1 0.0 0.0 208 0.5 9 DAY TANK 52D CONTROLS B 20 1 0.5 4.2 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 1.0 13 AHU -52 -D3 MOTORS /ACUATORS A 20 1 1.0 8.3 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1 0.0 0.0 FLUSH: _' 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 1.0 39 GENERATOR ROOM RECEPTACLES B 20 1 1.0 8.3 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 A 50 3 0.0 0.0 PANEL T.C.L. 4 B 0.0 0.0 LOAD (kVA) 6 C " " 0.0 0.0 RCPT 1.0 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 5.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 1 16 B 0.0 0.0 TOTAL 6.0 • 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. ro 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 1.0 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 5.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 6.0 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 6.0 42 C 0.0 0.0 AMPS 16.7 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 1.0 0.0 5.0 0.0 KVA/AMPS: 2.5 20.8 3.0 25.0__ 0.5 4.2 • Mfg/Type: Square D 0.0 0.0 2.5 0.0 A CB Type: 1.0 0.0 2.0 0.0 B Remarks: - 0.0 0.5 0.0 C SDC 52 1 I VECA Electric PANEL: 152D -L2 • ROOM: 3RD FLOOR MECHANICAL ROOM FEED -THRU: LOADS FROM: M -52D VIA XFMR A B C -T LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 1 RECEPTACLE ON ROOF A 20 1 0.2 1.7 .0 3 AHU -52 -D1 MOTORS /ACUATORS B 20 1 1.0 8.3 AMP: 100 1.0 5 AHU -52 -D1 MOTORS /ACUATORS C 20 1 1.0 8.3 VOLTS: 120 7 A 20 1 0.0 0.0 208 9 B 20 1 0.0 0.0 PH: 3 11 C 20 1 0.0 0.0 WIRE: 4 13 A 20 1 0.0 0.0 BUS: AL 15 B 20 1 0.0 0.0 A.I.C.: 18K 17 C 20 1 0.0 0.0 MLO: YES 19 A 20 1 0.0 0.0 MCB: 21 B 20 1 0.0 0.0 3R: 23 C 20 1_, 0.0 0.0 FLUSH: 25 A 20 1 0.0 0.0 SURF: YES 27 B 20 1 0.0 0.0 29 C 20 1 0.0 0.0 31 A 20 1 0.0 0.0 IG GRND. 33 B 20 1 0.0 0.0 200% N: 35 C 20 1 0.0 0.0 FD THRU NO 37 A 20 1 0.0 0.0 DBL LUG 39 B 20 1 0.0 0.0 TOP: YES 41 C 20 1 0.0 0.0 BTM: 2 . A 20 1 0.0 0.0 PANEL T.C.L. 4 B 20 1 0.0 0.0 LOAD (kVA) 6 C 20 1 0.0 0.0 RCPT 2.2 8 A 20 1 0.0 0.0 LTG 0.0 10 B 20 1 0.0 0.0 EQP 0.0 12 C 20 1 0.0 0.0 HEAT 0.0 14 A 20 1 0.0 0.0 1 16 B 0.0 0.0 TOTAL 2.2 18 C 0.0 0.0 c 20 A 0.0 0.0 FEEDER T.C.L. d 22 B 0.0 0.0 LOAD (kVA) 24 C 0.0 0.0 RCPT 2.2 26 A 0.0 0.0 LTG 0.0 28 B 0.0 0.0 EQP 0.0 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 2.2 36 C 0.0 0.0 LG MTR 38 A 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 2.2 42 C 0.0 0.0 AMPS 6.1 - A 0.0 0.0 - B 0.0 0.0 - C 0.0 0.0 2.2 0.0 0.0 0.0 KVA/AMPS: 0.2 1.7 1.0 8.3 1.0 8.3 Mfg/Type: Square D 0.2 0.0 0.0 0.0 A CB Type: 1.0 0.0 0.0 0.0 B Remarks: - 0.0 0.0 0.0 C SDC 52 • • PERC C C PY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0828 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Incomplete Letter # DATE: 10 -15 -10 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1 t D Bul ding Division III Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-19-10 117/ Incomplete ❑ Comments: Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -16-10 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ) 2 : S " 211 O Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # tSt Revision # ` after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Sn L - 5 2.O3 Project Address: 335 5 50,1-1, \ loCt' PL ac-e I t„\ \„n 1 c \4 A Contact Person: Pre:, ss \c Phone Number: 23( - e636 2 Summary of Revision: �j jj 1 \\ � Affil - 11n I ]-('C,v, LL (;■ iC.lA rY C Q f ). P C/� S - w PID u S to 0 fri' S p 1 r a�.Ae.cX. row, Pl7 U. s nY ci-A- r Pi Go�., H„�V,% Net t'ox Vc `�O OOO Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: I. Entered in Permits Plus on H:Wpplications\Fonns- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 Contractors or Tradespeople Peter Friendly Page • ■ Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7Th Ave 5 PO BOX 80467 Seattle WA 98108 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601190731 Active VECAECI542MU Electrical Contractor 7/31/1946 10/31/2011 General Unused Master Electrician INFORMATION License CONTIK *965D6 Name CONTI, KEITH Status Active Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON Agent 01/01/1980 929407110 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 01/06/2007 6 TRAVELERS CAS & SURETY CO 0815103520497 01/06/2001 Until Cancelled 01/06/2007 E54947 $4,000.0001 /05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBOES00247 5/30/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $2,000.00 EBOES00447 3/9/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EJONV00207 9/13/2005 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 E54947 8/8/2005 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000556 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000548 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000561 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000547 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000559 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 https://fortress.wa.gov/lni/bbip/Print.aspx 11/15/2010 10 SAB FY DA SDC1==52, C ELECTRICAL INDEX SHEET SHEET NUMBER TITLE E0.0 ELECTRICAL COVER SHEET E0.01 ELECTRICAL SYMBOLS LEGEND E0.02 ELECTRICAL ABBREVIATIONS E2.12 SECOND FLOOR POWER I E2.22 SECOND FLOOR COMM E2.32 SECOND FLOOR UGHTING E2.42 SECOND FLOOR MECHANICAL E5.12 ONEUNE DIAGRAM efi- !I E COPY Permit Na S Plem review approval is subject to errors and omissions. Approval of construction documents does not authorize Cc violation of any adopted code or ordinance. Receipt of approved Field Copy and candy aclmowledged: BY . .4 Debt ` / /a OtyOf war WILDING DIVISION REVISIONS No r.,:,,anges shalt be made to the scope of work without prior approval of Tukwila Building Division. NOT .: i"e" lions wilt require a new plan submittal L 'I'- I include additional plan review fees. L1O REVIEWED .FOR COMPLIANCE WITH NFPA 70 • NEC NOV 10 2010 Cky dilemma BUILDING DIVISION RECEIVED OCT 15 2010 PERMIT CENTER CORPORATION nternational Blvc 12201 Tukwila N O < O o) O N a)) U- CV • O •O N N co • co 0 o O • N u. u) I— LL J co 0 to O 0 0 0 M �c 0 QE • dQQ�I� 0 N N U ) u) (A • CALLISON SDC52 -03B ISSUED / REVISED DATE PERMIT SET 10/08/10 tIIFCInnpmprrIFIreTIrIM GGGe AT @TIRAC !'•f1OVOl!_uT r 9nnO f•AI 1 IOf kI INDEX SHEET E0.0 10 REFERENCE SYMBOLS LEGEND SYMBOL ab BUILDING NORTH • DESCRIPTION DETAIL SYMBOL ; A- IDENTIFYING NUMBER B -SHEET WHERE DETAIL IS SHOWN ELEVATION OR SECTION SYMBOL A- IDENTIFYING NUMBER - B-SHEET WHERE DETAIL IS SHOWN ARROW EQUIPMENT IDENTIFICATION SYMBOL REFER TO -EQUIPMENT SCHEDULE REFERENCE NOTE TAG SYMBOL • A - NOTE NUMBER . LIGHTING FIXTURE IDENTFICATION .SYMBOL REFER TO LIGHTING FIXTURE SCHEDULE. POWER .RACEWAY /CABLE IDENTiFICATION SYMBOL REVISION SYMBOL REFERENCE PHOTO NUMBER & DIRECTION CONTROL RACEWAY IDENTIFICATION SYMBOL IA RAM SYMBOLS LEGEND - GENERAL SYMBOL PLAN DIAGRAM DESCRIPTION —0 1 0 m CONDUCTORS - CONNECTED CONDUCTORS - NOT CONNECTED CONDUIT CONCEALED IN WALL OR CEUNG IN FINISHED AREAS, EXPOSED IN UNFINISHED AREAS . CONDUIT - ROUTED'' UNDERFLOOR OR UNDERGROUND GROUND WIRE LOW- VOLTAGE WIRING, SURFACE METAL RACEWAY(SHOWN WITH JUNCTION BOX) FIRST NUMBER INDICA NUMBER OF RECEPTACLES SECOND NUMBER INDICATES SPACING OF RECEPTACLES IN INCHES EXISTING TO BE REMOVED (CROSS HATCHED) HEAVY UNEWEIGHT INDICATES NEW WORK LIGHT UNEWEIGHT INDICATES EXISTING INFORMATION CONDUIT OR CABLE DOWN CONDUIT OR CABLE UP CONDUIT CAPPED FLEXIBLE CONDUIT HOME RUN - NUMBER OF CONDUCTORS AS INDICATED SMALL HASH MARKS INDICATE PHASE CONDUCTORS LARGER HASH MARKS INDICATES NEUTRAL BACKSLASH INDICATES GROUND WIRE BACKSLASH WITH DOT INDICATES ISOLATED 'GROUND , ALL UNMARKED CONDUIT RUNS ARE 1/2" CONDUIT ' WITH 2 #12 & 1 112 GND,,,UNLESS NOTED OTHERWISE. SINGLE -POLE SWITCH SWITCH - LOWER CASE LETTER INDICATES SWITCHING GROUP SUBSCRIPT INDICATES: 2 2-POLE 3 3-WAY 4 4 -WAY D DIMMER WP WEATHERPROOF LV LOW- VOLTAGE K KEYED OS OCCUPANCY SENSOR T TIMER. HOA AND- OFF -AUTO JUNCTION BOX SYMBOLS LEGEND - GROUNDING SYMBOL PLAN DIAGRAM DESCRIPTION i GROUND CONNECTION GROUND ROD GROUND WELL 0 4 ICS1 -1 SYMBOLS LEGEND =' LIGHTING LIGHTING FIXTURE': ADJACENT NUMBIat .INDICATES CIRCUIT GROUPING LOWER CASE LETTER INDICATES SWITCHING GROUP "NC ADJACENT; TO FIXTURE INDICATES NIGHT UGHT DESCRIPIIQN SYMBO SYMBOLS LEGEND - POWER DESCRIPTION SYMBOL SYMBO''S L GENE - POWER • SYMBOLS LEGEND COMMUNICATION DESCRIPTION SURFACE - MOUNTED FLUORESCENT "L GH 1NG FIXTURE WITH JUNCTION BOX TYPE AS NOTED, SIZE AS SHOWN RECESS- M0UNTED` FLUORESCENT ,LiGIONG FIXTURE WiTH JUNCTION BOX, TYPE AS NOTED, SIZE AS SHOWN RECESS - MOUNTED, LAY -IN, FLUORESCENT LIGHTING FIXTURE (TROFFER) :`TYPE AS NOTED, SIZE AS SHOWN SHADING INDICATES EGRESS LUMINAIRE ON EMERGENCY 01RCUIT OR WITH BATTERY BACKUP BALLAST ` (iYPICAL) PENDANT-MOUNTED FLUORESCENT LIGHiING FIXTURE - TYPE AS NOTED, SIZE AS. SHOWN (CEIUNG MOUNTED J -BOX SHOWN) WALL- MOUNTED 'FLUORESCENT LK;fiaNG FIXiURE — TYPE AS NOTED, ,SIZE AS SHOWN RECESSED, WALL- MOUNTED FLUORESCENT UG TANG FIXTURE WiTH JUNCTION. BOX - TYPE AS -NOTED STRIP FLUORESCENT LIGHTING FIXTURE TYPE AS NOTED STRIP FLUORESCENT UGHITNG FIXTURE ON EMERGENCY CIRCUIT - TYPE AS -NOTED STAGGERED STRIP FLUORESCENT FIXTURE TYPE AS NOTED WALL-MOUNTED 'UGHiiNG FIX1URE TYPE AS 'NOTED WALL - MOUNTED LIGHTING FD(TURE ON EMERGENCY CIRCUIT - TYPE AS NOTED WALL WASH FIXTURE - TYPE AS NOTED PENDANT- MOUNTED UGHTTNG FIXTURE - TYPE AS NOTED CEILING- MOUNTED UGHIING FIXTURE — TYPE AS NOTED CDUNG- MOUNTED UGH11NG FIXTURE ON EMERGENCY CIRCUIT -, TYPE AS NOTED DIRECTIONAL LIGHTING FIXTURE TYPE AS NOTED DIRECTIONAL UGHi1NG FIXTURE TYPE AS NOTED INDICATING UGHT - TYPE AS NOTED A- AMBER; B -BLUE; G- GREEN; R -RED; W -WHITE TRACK UGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN REXENE TRACK UGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN , RECESSED TRACK LIGHT - TYPE AS NOTED NUMBER OF HEADS AS SHOWN ILLUMINATED EXiT SIGN - SINGLE FACE ARROW INDICATES DIRECTION OF. EGRESS ILLUMINATED EXIT SIGN DUAL FACE WALL MOUNTED` ILLUMINATED EXIT SIGN - SINGLE FACE WALL MOUNTED SELF CONTAINED EMERGENC( LIGHT COMBINATION SELF CONTAINED EMERGENCY WAILPACK/EXIT LIGHT POLE- MOUNTED UGH TING FIXTURE TYPE AS NOTED NUMBER OF ,FIXTURES AS SHOWN DAERIOR HUMAN SCALE LUMINAIRE,' TYPE AS NOTED EXTERIOR LANDSCAPE LUMINAIRE, TYPE AS NOTED EXTERIOR STEP UGHTING FIXTURE - TYPE AS NOTED PHOTOELECTRIC CONTROL - CEILING MOUNTED ADJACENT LETTER P INDICATES PENDANT MOUNTED OCCUPMICY SENSOR - CEUNG MOUNTED ADJACENT LETTER W INDICATES WALL MOUNTED U - ULTRASONIC IR - PASSIVE INFRARED DT - DUN. iECHNOLOGY ILLUMINATION CONTROL STATION WITH DESIGNATION CONTACTOR SUBSCRIPT INDICATES NUMBER OF POLES CONTACT NUMBER INDICATES REFERENCE LETTER INDICATES FUNCTION RELAY COIL CR- CONTROL RELAY; TD 11ME DELAY RELAY; UV- UNDERVOLTAGE RELAY; M -MOTOR CONTACTOR NORMALLY OPEN NORMALLY CLOSED 11UE CLOCK POWER SUPPLY CB 04 1 -25-1 0 gati ca • HH -1 MH -1 FOP ❑i -111- 480V 120V -34 —I HD -®— T METER COMBINATION; STARTER HP RAZED,, 3 : POLE, NEMA SIZE' 1 MINIMUM UNLESS NOTED OTHERWISE OVERCURRENT PROTECTION SIZED BY EQUIPMENT MANUFACTURER OR AS NOTED .ASTER 3 -POLE, NEMA SIZE '1 MINIMUM' UNLESS NOTED OTHERWISE J —00- DISCONNECT 'SWITCH 3- POLE UNLESS NOTED OTHERWISE - OVERCURRENT' PROTECTION SIZED BY, EQUIPMENT: MANUFACTURER OR AS NOTED CIRCUIT 'BREAKER NUMBER INDICATES TRIP SETTING AND NUMBER . OF POLES CL - INDICATES'. CURRENT UMiI1NG .. ST — INDICATES SHUNT`TRIP TRANSFORMER POLE- MOUNTED TRANSFORMER SUBSCRIPT NUMBERS INDICATE:' FIRST NUMBER - NUMBER OF TRANSFORMERS SECOND NUMBER - TRANSFORMER kVA RATING hIRD NUMBER NUMBER. OF PHASES PAD, MOUNT TRANSFORMER,, DELTA. WYE OPEN DELTA GENERATOR MOTOR CONNECTION - SEE SCHEDULE FOR MOTOR DATA MANUAL MOTOR STARTER 480Y/271V, 30, 4-WIRE SURFACE MOUNTED PMIELBOARD 208Y/120V, 30, 4- WIRE, SURFACE MOUNTED PANELBOARD 208Y/120V 30, 4 -WIRE, RECESS WAIL MOUNTED PANELBOARRD EQUIPMENT CABINET - SURFACE MOUNT, TYPE AS NOTED BATTERY. EQUIPMENT CONNECTION POWER POLE PULLBOX HANDHOLE WITH DESIGNATION MANHOLE WITH DESIGNATION PUSHBUTTON P - INDICATES WITH PILOT UGHT EQUIPMENT EMERGENCY POWER OFF (EPO) SWITCH MICROPROCESSOR COIMROILED MONITOR REFER TO SPECIFICATIONS FOR METERING VALUES AND PROTECTIVE FUNCTIONS CURRENT TRANSFORMER QUANTi1Y AND RATIO AS INDICATED BREAKER WITH EXTERNAL GROUND FAULT RELAY AND CT CIRCUIT BREAKER VMH GROUND FAULT PROTECTION NUMBER INDICATES TRIP SETTING AND NUMBER OF POLES MOTOR -OPERATED CIRCUIT ' BREAKER NUMBER INDICATES TRIP SETTING AND NUMBER OF POLES SWITCH WiTH EXTERNAL GROUND FAULT RELAY AND CT POIENTTAL TRANSFORMER QUANTITY AND VOLTAGE RATING AS INDICATED SURGE ARRESTORS FUSE WITH RATING MOTOR THERMAL OVERLOADS - (3) UNLESS OTHERWISE NOTED 2- POSITION SELECTOR SWITCH Oep 1A PUSHBUTTON- SWITCH • MOMENTARY CONTACT HIGW`VOLTAGE: CABLE TERMINATOR SEPARABLE CONNECTOR DRAWOUT AC TYPE POWER CIRCUIT BREAKER AIR TERMINATOR LIGHTNING ARRESTORS - NEUTRAL GROUNDING RESISTOR INDICATING INSTRUMENT AM AMMETER; VM VOLTMEETER FM- FREQUENCY METER; WAR- KIIAVAR METER; kWH- KILOWATT HOUR METER; WAR/ID-KILOWATT . HOUR DEMAND NETER INSTRUMENT - `SWITCH AS- AMMETER SWITCH; VS- VOLTMETER SWITCH; SS- SYNCHRONIZING SWITCH; • SV- SUPERVISORY (LOCAL- REMOTE) SWITCH MN'' SURGE PROTECTION CIRCUIT CLOSING CIRCUIT OPENING RESISTOR SOLENOID VALVE MOTOR- OPERATED VALVE THERMOSTAT TERMINAL BLOCK NUMBER INDICATES REFERENCE RECEPTACLE OUTLET: SUBSCRIPT NUMBER INDICATES CIRCUIT GROUPING SUBSCRIPT LETTER INDICATES: XP EXPLOSION PROOF Gf GROUND FAULT CIRCUIT INTERRUPTER WP .WEATHERPROOF IG ISOLATED GROUND C CEILING MOUNTED S SURFACE MOUNTED GROUNDING -TYPE SINGLE RECEPTACLE GROUNDING -TYPE DUPLEX RECEPTACLE GROUNDINGiYPE DOUBLE DUPLEX RECEPTACLE SPLIT -WIRED GROUNDING -TYPE DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE - TYPE AS NOTED FLUSH FLOOR BOX WITH HINGED DEVICE COVER FLUSH FLOOR BOX WITH DEVICES AS NOTED PEDESTAL - MOUNTED DEVICES ON FLOOR BOX OR FLOOR DUCT FLUSH FLOOR COUPLING WITH RECEPi'ActE FLUSH FLOOR' COUPUNG WITH SINGLE PEDESTAL RECEPTACLE 0413 4aW. MEI 4> MICROPHONE OUTLET SPEAKER: S- SECURITY; F -FIRE ALARM LOWER —CASE LETTS INDICATES SWITCHING GROUP SPEAKER CEILING SURFACE-MOUNTED SPEAKER (`RUNG RECESS— MOUNTED SPEAKER - WALL SURFACE- MOUNTED SPEAKER - WALL:, RECESS- MOUNTED AUXILIARY INPUT.: VOLUME CONTROL AUDIO/VIDEO 'SYSTEM JACK: COMPUTBVDATA OUIT.ET FLUSH. FLOOR` COUPLING WITH PEDESTAL TELEPHONE OUTLET COMBINATION VOICE/DATA . OUTLET. SUBSCRIPTS INDICATE: A COMPLIES WITH AIi. QA D - DESK - MOUNTED P - PAY PHONE W WALL, MOUNTED ' a Z O `2 . r1 C cg 0:c d ca OC — O .3 • -Nc W a 0 N N 0 0 0 LL. 0 0 ti co T 0 N 0 0 206 282 9951 INTERCOM STA110N - SUBSCRIPT :INDICATES: D DESK- MOUNTED STATION OUTLET M - MASTER ;STATION W WALL- MOUNTED OUTLET INTERCOM SWITCH ti TELEPHONE OUTLET SUBSCRIPT INDICATES: A - COMPLIES WITH A.D.A. D - DESK- MOUNTED P PAY PHONE W - WALL- MOUNTED TELEVISION OUTLET CLACK WALL - MOUNTED CLOCK - CEILING- MOUNTED, DOUBLE -FACED CLOCK AND SPEAKER COMBINATION INTERCOM MASTER STATION INTERCOM REMOTE STATION ANNUNCIATOR - TYPE AS NOTED SYMBOLS LEGEND - FIRE ALARM SYMBOL PLAN DIAGRAM DESCRIPTION SYMBOLS LEGEND - SECURITY SYMBOL PLAN DIAGRAM DESCRIPTION oa WP PT/ CCTV CAMERA - FIXED WP INDICATES WEATHER PROOF CCTV CAMERA - PAN, 11LT, ZOOM SECURITY SYSTEM MOTION SENSOR • SECURITY SYSTEM DOOR/WINDOW CONTACT ACCESS CONTROL KEYPAD ACCESS CONTROL CARD READER ACCESS CONTROL REQUEST TO EXIT SECURITY SYSTEM DOOR LOCK 04C ❑4 110 110 0 • 6 cD 0 • • 0 Ka 0 FIRE ALARM HORN STROBE COMBINATION _ WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA. ADJACENT LETTER "C" DENOTED CEIUNG MOUNTED. ARE ALARM MINI -HORN - WALL MOUNTED FIRE ALARM STROBE WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA ARE ALARM BELL STROBE COMBINATION -WALL MOUNTED SUBSCRIPT INDICATES STROBE CANDELA FIRE ALARM PULL STATION FIRE ALARM SYSTEM CONTROL PANEL ESR ELEVATOR STATUS/RECALL FAC - FIRE ALARM' COMMUNICATOR FCP FIRE ALARM CONTROL PANEL FSA - FIRE SYSTEM ANNUNCIATOR HCP HALON CONTROL PANEL TWA - HVAC OR EXHAUST STAIRWELL PRESSURIZATION FIRE ALARM ANNUNCIATOR FIRE ALARM RELAY FIRE FIGHTER PHONE JACK ARE ALARM SPRINKLER TAMPER SWITCH FIRE ALARM SPRINKLER FLOW SWATCH FIRE ALARM SPRINKLER SUPERVISORY SWATCH FIRE ALARM SPRINKLER LOW PRESSURE SWITCH ARE ALARM DUCT SMOKE DETECTOR - WITH TUBE FIRE ALARM SMOKE DETECTOR - CEIUNG MOUNTED FLAME DETECTOR FIRE ALARM CHIME FIRE ALARM HEAT DEiECTOR - CEIUNG MOUNTED ALARM BUZZER A- ALARM; F -ARE; S- SECURITY FIRE/SMOKE DAMPER GAS DETECTOR ARE ALARM TERMINAL CABINET PROJECT GENERAL NOTES: 1. SYMBOLS SHOWN IN THE LEGEND ARE TYPICAL NOT ALL SYMBOLS MAY APPLY TO THIS PROJECT. 2. PROVIDE ALL MATERIALS, LABOR AND EQUIPMENT REQUIRED FOR A COMPLETE AND OPERATIONAL INSTALLATION. MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENTS .k OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, THE INTERNATIONAL BUILDING CODE, AND THE LAWS AND REGULATIONS OF THE STATE OF WASHINGTON. REVIEWED FOR COMPLIANCE H NF NEC NuV 10 2010 C�NQ DIVISION a BUILDI RECEIVED OCT 15 2010 PERMIT CENTER EL10- O5Z S • 0 u) 1 1 0 Q cu T m0acp cr) 1- w N� 0 u .ca < • Lo -se M LLU c) I- 1-- Z E 0 Z O c J N acs a° O ISSUED / REVISED DATE PERMIT SET 1 0/08/1 0 LEGEND E0.01 LIST OF ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION A AMMETER, AMPERE OR AMPS GALV GALVANIZED PRi PRIMARY ABND' ABANDON GEN GENERATOR PS POWER SUPPLY ABV ABOVE GFI GROUND FAULT CIRCUIT INTERRUPTER PT POTENTIAL TRANSFORMER AC ALTERNATING CURRENT GRS GALVANIZED RIGID STEEL PVC POLYVINYL CHLORIDE AF AMP FRAME PWR POWER AFF ABOVE FINISHED FLOOR H HEIGHT (HIGH) % PERCENT AFG ABOVE FINISHED GRADE HH HANDHOLE AHU AIR HANDLING UNIT HID HIGH INTENSITY DISCHARGE QTY QUANTITY AIC AMPS INTERRUPTING CURRENT HOA HAND-OFF-AUTO AL ALUMINUM HORIZ HORIZONTAL R RESISTANCE, RADIUS, REMOTE APPROX APPROXIMATELY HP HORSEPOWER RECD RECEIVED ARCH' ARCHITECTURAL HPS HIGH PRESSURE SODIUM REC RECEPTACLE AT AMP TRIP '' HT HEIGHT RED REDUCER ATS AUTOMATIC TRANSFER SWITCH HTR HEATER REF REFERENCE AUTO AUTOMATIC HV HIGH VOLTAGE REQD REQUIRED AUX AUXILIARY REV REVISION AWG AMERICAN WIRE GAGE I CURRENT RPM REVOLUTIONS PER MINUTE IBE INSTALLED /CONNECTED BY ELECTRICAL RM ROOM BATT BATTERY !BO INSTALLED BY OTHERS RS RAPID START BC BOLT CIRCLE, BARE COPPER IC INTERRUPTING CAPACITY RTU REMOTE TERMINAL UNIT BKR BREAKER ICS ILLUMINATION CONTROL STATION RVAT REDUCED VOLTAGE AUTOTRANSFORMER BLDG BUILDING ID INSIDE DIAMETER RVNR REDUCED VOLTAGE NON - REVERSING BOT BOTTOM IDF INTERMEDIATE DISTRIBUTION FRAME BTWN BETWEEN IJB INSTRUMENT JUNCTION BOX S SOUTH INCL INCLUDING SCADA SUPERVISORY CONTROL AND C CONDUCTOR, CONDUIT OR CENTIGRADE IN INCH OR INCHES DATA ACQUISITION CAB CABINET INST INSTANTANEOUS SCHED SCHEDULE CAT CATALOG INSTR INSTRUMENT SEC SECONDARY OR SECOND CB CIRCUIT BREAKER SECT SECTION CKT CIRCUIT J, JB, J -BOX JUNCTION BOX SF SUPPLY FAN CLG CEILING SHLD SHIELD OR SHIELDED CO CONDUIT ONLY WITH PULL STRING k THOUSAND SHT SHEET COL COLUMN kcmil THOUSAND CIRCULAR MILS SK SKETCH COMM COMMUNICATIONS kV KILOVOLT SIM SIMILAR CONC CONCRETE kVA KILOVOLT AMPERES SPDT SINGLE -POLE DOUBLE -THROW COND CONDUIT kVAR KILOVOLT AMPERES REACTIVE SPEC SPECIFICATION(S) CONN CONNECT / CONNECTION kVARH KILOVARHOUR SQ SQUARE CONSTR CONSTRUCTION kW KILOWATT SS STAINLESS STEEL CONT CONTINUOUS kWH KILOWATT HOURS ST SHUNT TRIP or STREET CONTR CONTRACTOR kWHD KILOWATT -HOUR DEMAND STD STANDARD COORD COORDINATE STL STEEL CP CONTROL PANEL L LENGTH, LOCAL STRUCT STRUCTURAL CPT CONTROL POWER TRANSFORMER LCP LIGHTING CONTROL PANEL SUB SUBSTITUTE CR CONTROL RELAY LED LIGHT EMITTING DIODE SUBSTA SUBSTATION CS CONTROL STATION LF LINEAR FOOT /FEET SUPT SUPPORT CT CURRENT TRANSFORMER LS LIMIT SWITCH SV SOLENOID VALVE CTR CENTER LT LIGHT SVC SERVICE CTRL CONTROL LTG LIGHTING SW SWITCH CU COPPER LTS LIGHTS SWBD SWITCHBOARD LV LOW VOLTAGE SWGR SWITCHGEAR DC DIRECT CURRENT L -L LINE -TO -LINE SYM SYMMETRICAL DED DEDICATED SYNC SYNCHRONOUS DET DETAIL M OR MTR MOTOR SYNSC SYNCHROSCOPE DIA DIAMETER MATL MATERIAL SYS SYSTEM DIM DIMENSION MAX MAXIMUM DISC DISCONNECT MCA MINIMUM CIRCUITAMPACITY T THERMOSTAT DISTR DISTRIBUTION MC METAL CLAD CABLE TB TERMINAL BLOCK DN DOWN MCC MOTOR CONTROL CENTER TBD TO BE DETERMINED DP DISTRIBUTION PANELBOARD MDF MAIN DISTRIBUTION FRAME TD TIME DELAY DWG DRAWING MECH MECHANICAL TEL TELEPHONE MFR MANUFACTURER TEMP TEMPERATURE OR TEMPORARY E r EAST /EMPTY MG MOTOR GENERATOR TERM TERMINAL OR TERMINATION EA EACH MH MANHOLE THHN HEAT-RESISTANT THERMOPLASTIC EF EXHAUST FAN MIN MINIMUM THRU THROUGH EL ELEVATION (HEIGHT) MISC MISCELLANEOUS THWN MOISTURE- AND -HEAT RESISTANT ELEC ELECTRIC / ELECTRICAL MLO MAIN LUGS ONLY THERMOPLASTIC ELEV EMERG ELEVATION (VIEW) , EMERGENCY MOCPD MAXIMUM OVERCURRENT PROTECTIVE DEVICE TOS TS TOP OF STEEL OR SUPPORT TAMPER SWITCH EMT ELECTRICAL METALLIC TUBING MR MULTI -RATIO TTB TELEPHONE TERMINAL BOARD ENCL ENCLOSURE MTD MOUNTED TTC TELEPHONE TERMINAL CABINET ENGR ENGINEER MTS MANUAL TRANSFER SWITCH TSP TWISTED- SHIELDED PAIR EOL END -OF -LINE DEVICE MVA MILLION VOLT-AMPERES TYP TYPICAL EPR ETHYLENE PROPYLENE RUBBER EQUIP EQUIPMENT N NEUTRAL OR NORTH UC UNDER COUNTER EWC ELECTRIC WATER COOLER NC NORMALLY CLOSED OF UNDER FLOOR EWH ELECTRIC WATER HEATER NEC NATIONAL ELECTRICAL CODE UG UNDERGROUND EXH EXHAUST NEMA NATIONAL ELECTRICAL UH UNIT HEATER EXIST OR (E) EXISTING MANUFACTURERS ASSOCIATION UL UNDERWRITER LABORATORIES EXT EXTERIOR NIC NOT IN CONTRACT UNO UNLESS NOTED OTHERWISE NL NIGHT LIGHT UPS UNINTERRUPTABLE POWER SUPPLY F FUSE OR FAHRENHEIT NO. NUMBER UTP UNSHIELDED TWISTED PAIR FA FIRE ALARM NO NORMALLY OPEN FBO FURNISHED BY OWNER OR OTHERS NTS NOT TO SCALE V VOLTS FC FOOTCANDLE VAR VOLT AMPERE REACTIVE FCP FIRE ALARM CONTROL PANEL OC ON CENTER VERT VERTICAL FDN FOUNDATION OCPD OVERCURRENT PROTECTIVE DEVICE VM VOLTMETER FDR FEEDER OD OUTSIDE DIAMETER FHP FRACTIONAL HORSEPOWER OFCI OWNER FURNISHED CONTRACTOR W WATTS, WIRE, WEST, WIDTH FIN FLR FINISHED FLOOR INSTALLED W/ WITH FIXT FIXTURE OL OVERLOAD WH WATTHOUR FLA FULL LOAD AMPERES OPNG OPENING WHSE WAREHOUSE FLEX FLEXIBLE CONDUIT OPP OPPOSITE WM WATTMETER FLR FLOOR W/O WITHOUT FLUOR FLUORESCENT P POLE WP WEATHERPROOF FO FIBER OPTIC PA PUBLIC ADDRESS WT WEIGHT FT FOOT OR FEET PB PULLBOX FTG FITTING PBX PRIVATE BRANCH EXCHANGE X REACTANCE FU FUSE PE PHOTOELECTRIC SENSOR XFMR TRANSFORMER FUT FUTURE PF POWER FACTOR XHHW MOISTURE /AND HEAT-RESISTANT FV FULL VOLTAGE PH or % %c PHASE CROSS- LINKED SYNTHETIC POLYMER FVNR FULL VOLTAGE NON - REVERSING PKG PACKAGE XLP CROSS - LINKED POLYETHYLENE FVR FULL VOLTAGE REVERSING PLCS PLACES XP EXPLOSION PROOF PNL PANEL OR PANELBOARD G OR GND GROUND PR PAIR Z IMPEDANCE GA GAUGE PREFAB PREFABRICATED 10 REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC NOV 10 2010 City of Tukwila BUILDING DIVISION LlO-O828 RECEIVED OCT 15 2010 PERMIT CENTER OD co Z O 2_ N 1- cm c Lo ▪ ai o O c co d 0 0 ' E o Ln • rn I O) ` O 0Q co o) ✓ -Y O� N u co OD A 1 N N N p 1111-= co co w m a 0 0 a N N N O LLNHL1 • 0 14 N 0 00 v 8 SDC52 -03B NTERGATE EAST CAMPUS Nco co o to —CL 4:0 O) ••Imaa 0 gt- N CO M ISSUED / REVISED DATE PERMIT SET 10/08/10 ABBREVIATIONS E0.02 1 2 ••••••"•": • ",k STS-52-BD re 3-4/0, 114 PDU-52- PDU-52- BD1 -1 001-1 STS-52-DB3 STS-54-DB3 • c , V ,,................„„....„.........,_..........., :: $. •• , •.: 1PDU -52- PDU 1BD3-1 DB3-1 2 2 52A-L2-9 2 ,,,,:3, „, ....„, ,.::.4...,... / •••” , . , .... .... ' .... ik 3 . ; 1 1 : $$. POU-52- PDU-52- CD3- 1 DC3-1 $ 52B-L2-9 rc 3-4/0, 114 CND STS -52 -BD 1 2t 3-4/0, 1-#4 CND STS-5g-0t31 $ • I i3-4/0, 114 OH D .• • PDU-52- PDU-52-4 - • - - "- (Dl -2 OBI-2 • •,•••:•••,: • • • • :•„•••••": • •g, ,,,,,,,,,,,,,,,,,,,,,,,,, STS-52-03 • 1 STS-52-D03 rc 3-4/0, 114 OD STS-52-CD3 , — 52A-L2-9 1 .,, . '...‘„ \ N ....0"01 \ , --,, STS-52-BD MDP-52-D1 3-5001.01, 1-0 CND MDP-52-B1 3"C 3-500MCM, 1-2 GND MDP-52-D1 3t 3-500KM, 112 CND MDP-52-B1 3-500MCM, 112 GND I: , i 1 $ :.: PDU-52- PDU-52- BD3-2 DB3-2 2t 3-4/0, 1-0 GND •.$ 1.3-4A 1-40ND STS-5g-DC3 O M ,•• 1.:2„ ; PDU -52- PDU-52-il ;$ - CO3-2 DC3-2 k 1{12*21/4° GROUND GAR STS-52-DC3 MDP-52-83 re 3-500ileN, 112 CND „.7,.,•,'`'''');— 1 1 g - rt 3-500MDM, 1-2 CND MDP-52-D3 STS-52-DB3 STS-52-CD MDP-52-03 g D MDP-52-D3 re 3-500MCM, 1-#2 %ID MDP-52-B3 3t 3-500101, 112 GND MDP-52-C3 re 3-500MCM, 1-#2 GND MDP-52 -03 3t 3-500MCW, 1-2 CND 2 REVIEWED .FOR COMPLIANCE WITH NFPA 70 • NEC NOV 1 0 2010 BUILDING DIVISION ELI04-064 SCALE RECEIVED OCT 1 5 2010 PERMIT CENTER E 1 • Z t O 2 (\I 1.▪ co _... c ‘.---- RA t... 0 i Og (1) 4.4 CO O C CO cow. Dis co eg — CO 0.) 0 1.0 0 l'-- CD 0 0 1 h... 0 < C° CD >,* Q Z — C▪ O CO .0 >" I-- U., (1; C\I \I C w f3 Tu. 4w, CD C) " 4...' 0 0 (4 0.1 CN c s3 CNI C■I yz, OT—.11.601-11. 0 CD > (Y) C/) cL 2 0 La W w < z 0000•0116 ISSUED / REVISED DATE PERMIT SET 10/08/10 Level 2 POWER E-2.12 1 — 1 1 4 B C D C 2,_0" 2 2 2 • 2 2 B B C 4" MPOE CONDUIT EXTEND TO TRAY 3 4" X 16" BASKET TRAY TYP 2 2 2 4" MPOE TO ROOM #111 FLAG NOTES LEAVE ABOVE T -BAR FOR FUTURE USE REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC NOV 10 2010 E E City of Tukwila BUILDING DIVISION LO- o6).8 SCALE 1 /4''= '0" RECEIVED OCT 15 2010 PERMIT CENTER ............................................................................................................................................................................................................................................................................................. ............................... =I ' z N F W Q E m w p rr O co � 0. co O E O LO 0 p O V O .� p < co O >+ U O co, N N co JD ▪ I - LL. " N N N W y �., co co m o i-, p 0 3 Q, N O CO N N N O 0 3 (n r- LL. U) I— U_ J O O Lf> • O O O O C�r co E w .c g z a� o o 0 r01NI E Z ° Z 0 0 c N � o _rn J J = J J e0 `). V t) SDC52 -03B ISSUED / REVISED DATE PERMIT SET 10/08/10 Level 2 COMM E-2.22 ......... A A A A A A A A A 1. 1 1 1 ...... • • • • 1 — 2 7... B .... ............ A A 2 B B A OS ,,,,,,, `• ,,,,,,, A c B ,,,,,,,, • A •,. • 2 • • • • ■ • .. 222,2. lo A ,,,,,,,,,,,,,,,,,,,,,,,, B OS ,,,,,,,,,,,,,,,,,,,,,,,,, • A OS B ... ( 2 A A • • A A • • • , • OS OS B A 2.. • • ........................ • ........ 2 • ............................... ■ . .. OS A A 3 D 1, ................................................. ................................................................................................... .................................................................................................................................................... ....................... B E SHEET NOTES: — 2 E 1. CIRCUIT "A" DESIGNATED FIXTURES TO 52A—H1-11 2. CIRCUIT "B" DESIGNATED FIXTURES TO 52B—H1-11 3, PROVIDE 2 POLE OCCUPANCY SENSORS SYMBOLS 1/1 B.S. 18 CELL PARABOLIC 2 LAMP B.S. 18 CELL PARABOLIC 2 LAMP W/1 LAMP BATTERY BALLAST EXISTING B.S. 18 CELL PARABOLIC 2 LAMP B.S. 12' PENDANT DIRECT/INDIRECT O B.S. 6' FLUORESCENT DOWNLIGHT B.S. EXIT SIGN si WATT STOPPER OCCUPANCY SENSOR ......... — .... REVIEWED .FOR COMPUANCE WITH NFPA 70 - NEC NOV 1 0 2010 CftyofTukwiIa BUILDING DIVISION EL-10-08.46 SCALE RECEIVED OCT 1 5 2010 PERMIT CENTER E E ... v,-,1;;DATEssii-A — .. SABEY CORPORATION Tukwila International E ° z to o —1 — - .11 40 u cn a. a) 2 0 03 < CU C° • 0_ co (j) < I < CD CN1 LO 0 W CU 0 (0 < LO 0 Lo c.e) w 1— z ISSUED REV SED DATE PE RN; ru $ 1 0 /08/1 0 Level 2 LIGHTING E-2.32 3,, 34 19 1 A 2 2 — 3 A A . . . c 2 2 2 D B 0 2 D • .. D D D D 2 2 REVIEVVED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 1 0 2010 City &Tukwila BUILDING DIVISION too O8.z.8 SCALE 1 /4"= 1 '0" RECEIVED OCT 15 2010 PERMIT CENTEF m co Z c u o — co co .0 >. Lj- CNI C•1 111 'c 7,7. co co cn go 0 s. 0 c) (NI (NJ c‘i o efi u_ cn u. •u 8 3 8 ) 01 LO 9 E 2 < 8 uiE (N § (T° g 0 a. 2 0 co < (c) 0 0_ co c0 < c\I ILO W •t"-" W I) < Lr) 0 Lo w 1- z ISSUED / REVISED DATE PERMIT SET 10/08/10 Level 2 MECHANICAL E-2.42 SUITE 52 -01 SUITE 52 -020 Tnl17.1.1=1n522 3 C 13 (2) 6 "0, 3 #350KCM, 1 #2/0 GROUND 27KV SW I TC I GEAR — MSG-2 • (2) 6 "C, 3#350KCM, 1 #2/0 GROUND 3 -LA m 0 m 0 1200 MRCT 3 1200A MI 52 -1 BUS #1 00 50/51 50/51N 00 NC CO MICROPROCESSOR BASED RELAY AND METERING 27KV, 3PH, 4W, 1200A BUS 1 I I 1 1 1 1 1 1 I I 1 00 Oa0m J L_ C TO SYSTEM 5, SHEET NO. E5.5 SPACE FOR FUTURE BREAKER TO SYSTEM 6 600:5 MRCT (TYP) 1 200A 52 -4 m 50 51 1 200A 52 -F 0 0 0 N.O. 52 -3 0 ®® 50/51 50/51 3 -LA 1200 3 MRCT 0 27KV, 3PH, 4W, 1200A BUS INC m 0 M2 1200A 52 -2 BUS #2 0 0 ---=--------------------------------- & 1# 2 /01GROUNDD,141 /0050N( 35KV 600:5 MRCT (TYP) 1200A 52 -F4 :.52....14'1 -7A.- HVS 600A, 27KV 110KV BIL DIST. SWBD "HDP -52A" 4000 XFR -52A 3000 KVA M 80'0 26.4/15.3KV- 480/277V 4000AT 4000A BUS 480V- 30 -4W -65 KAIC t i F ! ! a Lin B $40004 s -- _i___i_____L 52 -1B 52 -20 HVS XFR -52B O 60DA, 27KV 3000 KVA 11OKV BIL AA 80'0 26.4/15.38V- 480/277V J 4000A ------ - - - -__ - lE AT 3( 2500 KW 3125 KVA GENERATOR "GEN 52A" Y 444044 C 1RANST R C0MR0 MODULE 4000AT 160087 100AT °` 50AT 3P 3P "/ 3P P L 52A -41 480 277 100 MCB XFR -528 -L 30KVA µA.4/4800 TO 208/1204 Oi PNL 52A -11 208/120 100A MCB PNL 52A 208/120 I OOA MLO 00AT III 11 III 200AT 1200AT 1200AT 1200 1200 200 PS -5 -A 625KVA/ 562KW FAB 200AT CD UPS -5 -A2 625KVA/ 562KW PRIMARY 1200AT I200AT 1200AT 1200AT III PS -5 625KVA/ 562KW PRIMARY 200AT 12003 -A3 M BP- 52 -•1 MAINT. BYPASS PANEL 30003w 480 NC 1200AT 1200AT ® NO ® MBP -52 MAINT. BYPASS PANEL 30003W 4804' A2 NC 1200AT 120044 ® NO ® MBP -52 MAINT. BYPASS PANEL 30003W 4804 •3 MBP -52 C3 MAINT. BYPASS PANEL 480V 30 -3W 443 400 NC 1200AT ® 1200AT ND 03 AB3 � 2 "C — 3 #1/0 & 1 #6G AD3 2 "C — 3 #3/0 & 1 #6G 0 400 BZ Ii,600 400 � i00 . ouo hoc 55 v 52 -03A 0S 52 -ACI 52 -03A 400.7 NOV 1155 w Ia511 4003 4003 T5 STS 52 -AB2 52 -AC2 52 -01A 52 -01A C) DC -52 -482 200A 3008V8 4804 TO 208/120 STARLINE BUSWAY P L M- 28 4 0 160 MLO 30 -3W 8FR 52A -L3 1584 114804 208 12TO 04 PNL 52A -L3 206/120 608 MCB STARLINE BUSWAY CD EP- SS 52 -AC3 52 -01A 300844 4804 TO 208/1209 PNL 52 -AC2L 208/120 ST 52 -AB3 52 -02A 4003 52 AD 52 -03A End ha-di 50121-1,15 50121.■ 800AT 4003 800AT 00 AT 800AT 1 I I 1 1 1 1 I IRON 1 1 I I1 1 200A 52 -7 0 col SPACE FOR FUTURE BREAKER TO SYSTEM 6 0 6 "C - 3 - 1/C #335DKCMIL 1 #2/O NEUTN211L 0 GROUND Lo.4M)a NK L_B--52B 3C.KVA 48€ v 3P3W 3.031 LiWiK 3A-44 TO SYSTEM s, SHEET No. css (FUTURE) TO SYSTEM 5, SHEET N0. E5.5 (FUTURE) 40004 1 DIST. SWBD "HOP -52B" 4000AT 40004 841 480V- 30 -4W -65 KAIC /6 MOM C TRANSFER CONTROL MODULE O 4000AT 2500 KW 3125 KVA GENERATOR "GEN -528" OOAi �1OAT ✓3P AT OA SPAT 3P TO COMMON LOAD PANEL STARLINE BUSWAY PNL 528 -NI 480/277 00A MCB XFR - 528 -L1 30893 KM./ 4130V To 208/1204 PNL 52B -LI 208 120 1008 MCB 0 PNL 52B L2 208/120 00A MLO 1 100AT 3P TYP 1200AT 1200AT-J1200AT 120• 1200 1200 UPS -5 B1 625KVA/ 562KW 1200AT TYP4 UPS III -- 10003 UPS -5 -B2 CD 6251148/ 562KW 200AT 1200AT 1200AT 1200AT. II IIII4-1 III 80044 800AT 800AT -------------- - - - --- j PS -5. -B3 625644/ 562KW PRIMARY 1200AT MBP- 52 -:1. MAINT. BYPASS PANEL 30003W 480V NC 1200AT 1200AT ® NO ® MBP -52 MAINT. BYPASS PANEL 30003w 480V B2 NC 1200AT 120044 ® NO ® MBP -52 MAINT. BYPASS PANEL 300480V B3 NC I200AT 1200AT NO MBP -52 C3 MAINT. BYPASS PANEL 480V 30 -3W 443 400 NC 1200AT 833 1200AT 13 03 DC3 400 600 2 "C — 3 #1/0 & 1 #6G 0 2 "C — 3 #3/0 & 1 #6G 0 2 "C — 3 #4/0 & 1 #4G 0 jii 00 0 STS 52 -BAI 52 -03A CD ItdiP Einni End ri ri 14003 PNL M -528 400 1600 ML0 PNL 52B -L3 208/120 0A MCB 30 -3W XFR - 528 -553 1 KVA 114 OV TO 235/120V PRO 0 4003 STARLINE BUSWAY 52 GC 52 -02A 0 INN EnIsi En-di 501Z5ER 50EIUYFR G m STS 52 -BA2 52 -01A 4003 m 0 STS 52 -BC2 52 -0 0 1111 191 End End ri ri C 55 52 -BA3 52 -029 0 4003 S5 52 BC3 52 02A 30 KVA 4003 m 2003 125. 125. 125KW 125Kw 50111AVER SOFTU +EP 50111n115 SOMA.., SOMME 50511.0.5ER OEPArw 5T 52 -BD3 52 -03A CD E E ri ri FUTURE EAST 52 -018 LEVEL 3 f H L__1 1___�_____L_ J L__1 1_ 52 -iC n'�=�C 52-10 771 XFR -527 HVS 3000 KVA HVS 6000, 271N 80,C 6004, 2785 1101N BIL 110KV 0155 26.4/15.3114 - 480/2774 0 --Er O 3000 KVA AA 80'C I DIST. SWBD "H DP -520" MEI 4000AT — __ AUTOMATIC TRANSFER CONTROL MODULE 4000A BUS 480V- 30 -4W -65 KAIC `160044 10044 ____�___�__T_ ��_------ .---- -____� 3P 3P 1 1 1 1 1 1 la FPNL-1 1480/2171 I 1004 MCB 1 I 1 1 1 1 1 1 1 PNL 52C 480 480 1600 MLO PNL 52C -L3 208/120 60A MC8 0 3,1T/25 KVA SPAT n «JF 00AT 1200AT 1200AT 1200AT 12 CO A 12004 12004 1 00AT 1200AT 1200A et. el el 1 - - - -- JPS -5 -01 I 1UPS -5 -C2 ri 304 -524 -L 3FK-A 480V TO 205/1204 PNL 1 52C -LI 1 1208/1201 100A MCB T COI r PNL1 520 -L2 1208/1201 004 MI01 30 -3W X R- 52C -L3 KVA 112 OV TO 2 8/1204 11 CDA UPS-5 -C3 FEEDER SCHEDULE 3—PHASE 4 WIRE + GROUND COPPER coNDUcToRs SYMBOL FEEDER sIzE — CONDUIT & WIRE SIZE + GRoUND 504 604 704 1004 2254 3-1/2"C — 4 #500KCMIL & 1#2G 0004 40004 FLAG NOTES: E> NOT USED STS TO HAVE (3) 225A OUTPUT BREAKERS [1:>.- REMOVE EXISTING PM820 POWER METER & REPLACE WM-I CM4000 liS>. FACTORY INSTALLED PM1350 POWER METER 12>- FACTORY INSTALLED PM820 POWER METER ,;[>. PROVIDE STATUS NOTIFICATION OF BREAKER POSMON VIA ACL MONITORING MONITOR AMPERAGE ONLY VIA ACL MONITORING NSTOST TuOSEHDAVE (1) 400A OUTPUT BREAKER FOR FUTURE LOADS [->. PROVIDE EATON XPERT 4000 POWER QUALITY METERS. MBP -52 MAINT. BYPASS PANEL 12004, 3m -3W 401 480 ''''® 400 1 NC 1200AT rrr B1 C01 ■ 1200AT 001 ® 40C MBP -52 C2 MAINT. BYPASS PANEL 4804 30 -3W CA2 400 ' NC 1200AT 1200AT ® TTT 00 CZ2C002 ® 0002 MBP -52 C3 MAINT. BYPASS PANEL 480V 30 -3W 443 400 NC 1200AT 833 1200AT 13 03 DC3 9464 52 -CAI 52 -04A 0 ut 4003 ST5 52 -001 52 -028 545 52 CBI 52 02A 0 I lasxw lzsxw 4003 52 CA2 5 -018 4003 4804 TO PNL 52 CB2L 208/ 20 .00-61-4661 STARLINE BUSY. • 52 CA3 52 A POC-52-C93 4804 TO 208/12 V STS 5 -024 52-028 300 KVA 505.. 50111.WW 50522,ER 20/111.1. STS 52 003 52 039 CD IOMMI HIP End En-di 4000A BUS 480V-30-4W-65 KAIC P 3P 3P 480/277 004 CB 4809 TO PNL FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND COPPER CONDUCTORS SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 0 1/2"C — 3 #12 & 1 #12G 0 3/4 "C — 3 #10 & 1 #10G 0 3/4 "C — 3 #8 & 1 #10G 0 3 /4 "C — 3 #6 & 1 #10G 003 1"c — 3 #4 & 1#8G (11003) 2 "C — 3 #1 & 1 #8G 1503 2 "C — 3 #1/0 & 1 #6G 0 2 "C — 3 #3/0 & 1 #6G 0 2 "C — 3 #4/0 & 1 #4G 0 2 -1/2 "C — 3 #250KCMIL & 1 #4G (ac;;;) 3 "C — 3 #500KCMIL & 1 #2G 5003 (2 SETS) 2 -1/2 "C — 3 #250KCMIL & 1 #2G .14 3 "C — 6 #300KCMIL & #2/0 G aoo3 (2 SETS) 3 "C — 3 #500KCMIL & 1 #1/0 PER SET 6200) (3 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #3/0 PER SET CO (4 SETS) 3-1/2°C — 3 #600KCMIL & 1 #4 /0G PER SET 20003 (5 SETS) 3 -1/2 "C — 3 #600KCMIL & 1 #250KCMIL PER SET 25003 (6 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #350 KCMIL G PER SET 30003 (8 SETS) 3 "C 3 #500KCMIL & 1 #400KCMIL G PER SET (ao(4 (10 SETS) 3 -1/2 "C 3 #600KCMIL & 1 #500KCMIL G PER SET TEMP EEO FRO MBP 52-AI AUTONAITC TRANSFER CONTROL MODULE 562KW STATIC SWITCH v CD 208/120 1004 MCB 604 208/120 UPS CD 0 TEMP FED FR MBP 52-A2 14000A y PRIMARY TEMP FED FRO MBP 52-A3 MAINT BYPASS k NC PANEL 12 1200A, 480 400 00 AI AD 10. 1200AT 00 BYPASS NC PANEL 1200AT 1200A, 4805 900 400 00 0 A2 A02 092 13 2 400 40C MDP- 52 D3 MAINT. BYPASS NC 1200A, 480V 400 0 ST CD End End 150 50 STS 52-001 52 02B MIN 10 STS 5 -0 3 CD End Enid 2 KW Clo Eild End ri CD End End 1 SOFTLAYER 52-02A COLO 52-02B FUTURE WEST 52-03B FUTURE EAST 52-0 I B LEVEL 3 REVIEWED FOR COMPLIANCE WITH NW 1 0 20111 BUILDING DIVISION 0-- 618 RECEIVEr PERMIT CENTEh le olE 0 IL CC ILI o • International Blvd. CO CO LL (NI CO Int nn 5I a 0 • op 0 N LO co ol) el CO CO CD c co c co co CO CD cp 0 • .0 8 www.callison.com Ig Lu en evi Q. tu NTERGATE EAST CAMPUS co co co cc ISSUED / REVISED DATE PERMIT SET 8/10/10 SDC52-03B ONE-LINE DIAGRAM E5.12