HomeMy WebLinkAboutPermit EL10-0877 - TESC POND #1TESL POND #1
SOUTHCENTER PY
SEGALE PARK DR C
EL1O-0877
Parcel No.: 3523049015
Address:
Cityalkf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Tenant Name: TESC POND #1
ELECTRICAL PERMIT
Permit Number: EL10 -0877
Issue Date: 11/15/2010
Permit Expires On: 05/14/2011
Owner:
Name: SEGALE PROPERTIES LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contact Person:
Name: BOB RAU
Address: 15321 105 AV CT E , PUYALLUP WA 98374
Contractor:
Name: R -C TRUE LINE CORPORATION
Address: 15321 105 AV CT E , PUYALLUP WA 98374
Contractor License No: RCTRULC038QG
Phone: 253 845 -8875
Phone: 253 845 -8775
Expiration Date: 11/07/2011
DESCRIPTION OF WORK:
INSTALLATION OF 400 AMP METERED SERVICE AND CONTROLS FOR STORM WATER PUMP
STATION
Value of Electrical Work: NRES: $15,000.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected: $438.13
National Electrical Code Edition: 2008
Date: L l Us i
I hereby certify that I have read and exan fined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie wit whether specified herein or not.
The granting of thi
construction or t
Signature:
Print Name:
does • •t p esume t• giority to violate or cancel the provisions of any other state or local laws regulating
an of ork. a a; r ed to sign and obtain this electrical permit.
Date: /" /5
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -9/09
EL10 -0877
Printed: 11 -15 -2010
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http://www.ci.tulcwila.wa.us
Parcel No.: 3523049015
Address:
Suite No:
Tenant:
TESC POND #1
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
EL10 -0877
ISSUED
11/01/2010
11/15 /2010
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to }ive aut
laws regulating construction or t I e r erfo . - n / f wor
Signature:
Print Name:
rity to violate or cancel the provision of any other work or local
6z6&__
doc: Cond -Elec
EL10 -0877 Printed: 11 -15 -2010
CITY OF TUK1 .A
Community Develr,N,nent Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.atukwila.wa.us
SITE LOCA;TIO
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address:
King Co Assessor's Tax No.:
Corner of South Center Blvd and Segale Pk Dr C
Suite Number:
Tenant Name:
Property Owners Name:
Segale Properties
New Tenant:
Floor:
❑ Yes Qj .. No
Mailing Address: P 4 Box 88028
CONTACT PERSON 7-Who'
Tukwila
City
WA
State
Name:
R - C True Line Corp
contact when your permit is .ready to be issued
15321 105th Ave Ct E
Mailing Address:
E -Mail Address: bob @rctrueline.com
98138
Zip
Day Telephone:
Puyallup
City
Fax Number:
(253) 845 -8875
WA 98374
State
(253) 845 -4652
Zip
ELECTRICAL. CONTRACTOR 1NFORMATIoN
Company Name: - / .- -- . 1< / C
Mailing Address: 15321 105th Ave CT E
Contact Person: Bob Rau
E -Mail Address: bob @rctrueline.com
Contractor Registration Number: RCTRULC038QG
Puyallup WA 98374
City State
Zip
Day Telephone: (253) 377 -7111
Fax Number: (253) 845 -8875
Expiration Date: 11/01/2011
Valuation of Project (contractor's bid price): $ 15,000
Scope of Work (please provide detailed information):
water pump station.
Installation of 400 amp metered service and controls for storm
Will service be altered? 0 Yes
Type of Use: Commercial
LZI No
Adding more than 50 amps? ❑ Yes Q) No
Type of work:
Q) New ❑ Addition
❑ Low Voltage ❑ Generator
Property Served by:
• Puget Sound Energy
❑ Seattle City Light
❑ Service Change
❑ Fire Alami
11 Applications \Forms- Applications On Line\2010 Applications\ -2010 - Electrical Penn it Applicati on. doe
bh
Page 1 of 2
❑ Remodel
❑ Tenant Improvement
O Telecommunication ❑ Temporary Service
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings
(including an attached garage)
❑ Garages, pools, spas and outbuildings
❑ Low voltage systems
(alarm, furnace thermostat)
$152.85
$81.90 ea
$59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added /altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added /altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
PER11 IT APPLICATION NOTE -
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured /mobile home service $84,00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not 10 exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAM r rtts AYPLI'ATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE to ern r.,
Print Name:
Mailing Address:
15321 105th Ave Ct E
1 Date Application Accepted:
, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Day Telephone:
Puyallup
City
Date: /t --4;Z9'.--/°
(253) 377 -7111
State
98374
Zip
Date Application Expires:
H. Apphcationslrorns.Applications On Line \2010 Applications17- -2010 - Electri cat Permit Applicati on, doc
bh
Page 2 of 2
oc
oLl
Staff Initials:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3523049015 Permit Number: EL10 -0877
Address: 18791 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 11/01/2010
Applicant: TESC POND 1 Issue Date:
Receipt No.: R10 -02204
Initials:
User ID:
JEM
1632
Payment Amount: $438.13
Payment Date: 11/01/2010 10:22 AM
Balance: $0.00
Payee: R. C. TRUE LINE CORPORATION
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 3299 438.13
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
ELECTRICAL PLAN - NONRES
000.322.101.00.00 350.50
000.345.832.00.00 87.63
Total: $438.13
doc: Receiot -06 Printed: 11 -01 -2010
INSPECTION RECORD \\I"
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
(206) 431 -3670
6,10 -0Y77
6300 Southcenter
Blvd., #100, Tukwila. WA 98188
Permit Inspection Request Line (206) 431 -2451
Project:
er
6c, st:),40. 4 1
Type of Inspection:
Add5.C. P
Date Called:
Special Instructibns:
Date Wanted:
ff'1-7
a.m
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
(l
L
Inspector:
60\146\
I I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6'ioot7j
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: a C Pakb ft 1
Type of Inspection:
Address: [ 7 - I
,r
Date Called:
Special Instructiojis: .
Date Wanted:
' + /14
a.m.
Requester:
Phone No:
❑ Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Inspector:
Date:
li II(�
0
n REINSPECTION FEE REQUIRED. I�rior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
N
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL10 -0877 DATE: 11/01/10
PROJECT NAME: TESC POND 1
SITE ADDRESS: SOUTHCENTER PY & SEGALE PARK DR C
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # after Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Planning Division
❑ Structural ❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete ri
DUE DATE: 11/02/10
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route
REVIEWER'S INITIALS:
Structural Review Required ❑ No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 11/30/10
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Pester Friendly Page
•
Electrical Contractor
A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name R -C TRUE LINE CORPORATION UBI No. 601828382
Phone 2538458875 Status Active
Address 15321 105Th Ave Ct E License No. RCTRULC038QG
Suite /Apt. License Type Electrical Contractor
City Puyallup Effective Date 11/7/1997
State WA Expiration Date 11/7/2011
Zip 98374 Suspend Date
County Pierce Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
TRUEL * *035KHTRUE
LINE
Electrical
Contractor
General
Unused
5/8/1997
5/8/1999
Archived
Master Electrician INFORMATION
License RAU *RRH967C3
Name RAU, ROBERT H
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
RAU, ROBERT H
Violation Amount
01/01/1980
8/10/2009
RAU, CARLOTTA
ELECTRICAL CITATION
01/01/1980
$250.00
RAU, ROBERT H
Agent
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
a INDEM CO
445594C
11/01/1997
Until Cancelled
$4,000.00
06/15/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
EREEB00414
8/10/2009
19.28.161 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https://fortress.wa.gov/lni/bbip/Print.aspx 11/15/2010
D
C
B
1' -0"
1
}
8"
1
8' -0"
6' -4"
30 amp Rain Tight
fused disconnect
Fused for 5 amp 480
5 KVA CONTROL TRANS
POWER FEED TO
120 BREAKER BOX
MAG STARTERS
# 3 CU
DISC
�/ INSTALL GROUND BAR INSIDE GUTTER AT BOTTOM CENTER
4' -0"
6' -6"
# 4 COPPER GROUND WIRE FROM BONDED NEUTRAL TO FRAME OF BANG
BOARD AND ONTO TWO GROUND RODS LOCATED 10 FEET APART.
= ,1II„rl�1.r.11.
I I_
=_-111-1117--
—1 i �-
I_ -I
2 - 4 ICH RIGID NIPPLES OUT OF BACK OF CT CAN AND INTO THE BACK OF
_ SERVICE DISCONNECT. PLACE NIPPLES SO THEY DO NOT INTERFER WITH
—CT'S
FRONT SIDE LAYOUT
TESC POND 1 POWER BOARD
2
'1= ;1Ii -1I1-
_III —_ -1 I.
1 O' —O"
3
o a
D
❑ ❑ ❑
400 AMP
SWITCH
❑ ❑ ❑
500 MCM COPPER
ann
CT CAN
TESC POND # 1
SERVICE 480 / 277 V 3PHASE 4 WIRE
FED FROM OVERHEAD POLE MOUNTED
PSE TRANSFORMES
PRESENT LOAD
PUMP 1 58 HP PUMP MOTOR = 54015 WATTS X 125 % =
PUMP 2 58 HP PUMP MOTOR
PUMP 3 58 HP PUMP MOTOR
GFI REC
GFI REC
WORK LIGHTS
FUTURE LOAD
PUMP 4 58 HP PUMP MOTOR
PUMP 5 58 HP PUMP MOTOR
4 INCH RIGID NIPPLE W / LOCK NUTS / PLASTIC BUSHINGS
AT TWO LOCATIONS TO CONNECT BACK TO BACK GUTTERS
Total
TOTAL AMPERAGE
67519 WATTS
54015 WATTS
54015 WATTS
1200 WATTS
1200 WATTS
200 WATTS
54015 WATTS
54015 WATTS
286179 WATTS
344
C
z
L
z
w
w
w~
Qw
Z 0_
OEO
wa_
ww
= J
1 % X 2 RIGID NIPPLE WITH GRD LN. USE BOND BUSHING IF GOING
THROUGH CONSENTRIC KO ON METER BASE
1
INSTALL 4 INCH PVC MALE W / LOCK NUT / PLASTIC BUSHING
BACK SIDE LAYOUT
TESC POND 1 POWER BOARD
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
NOV 10 2010
City of Tukwila
BUILDING DIVISIO
FIL
Permit No.
Plan review approval is
Approval of construction
the violation of any a
of app #.d
uthorize
Receipt
ed:
City • TWkwila
BUILDING DIVISION
CITY
Or TukwiLA
NOV 0 1 2010
PERMIT Ceackt
co
w
cc
w
n..
O
w
J
��w
V♦
•
w
z
4
z
W
3
4
tY
F-
U
J
J
4
1-
z
4
d
4
-J
4
w
U
cr
O
N
W
c.
J
4
z
J
F-
V
E2
J
w
O'
a
-
0 .
z
0
w
L
rta 414:
isc
W
�
'ara. !
F
•
PROJECT NUMBER:
DRAWING NUMBER:
sHEET:X
Of: