Loading...
HomeMy WebLinkAboutPermit EL10-0896 - SEGALE PROPERTIESSEGALE PROPERTIES S 200 ST & FRAGER RD EL 10-0896 Parcel No.: 0222049011 Address: City.' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Tenant Name: SEGALE PROPERTIES ELECTRICAL PERMIT Permit Number: EL10 -0896 Issue Date: 11/18/2010 Permit Expires On: 05/17/2011 Owner: Name: LA PIANTA LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: BOB RAU Address: 15321 105 AV CT E , PUYALLUP WA 98374 Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA 98374 Contractor License No: RCTRULC038QG Phone: 253 - 377 -7111 Phone: 253 845 -8775 Expiration Date: 11/07/2011 DESCRIPTION OF WORK: CONNECT SERVICE ENTRANCE FEEDER FROM CUSTOMER OWNED OIL FILLED TRANSFORMER TO TEMP SERVICE BACKBOARD, 400A 3 PHASE 480 V. RUN 200 AMP 480V 3 PHASE FROM TEMP POWER TO FILTER TRAILER Value of Electrical Work: NRES: $5,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Fees Collected: $223.13 National Electrical Code Edition: 2008 Permit Center Authorized Signature: ( Date: I hereby certify that I have read and examined t u'•ermit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specifie • erein or not. The granting of this pe construction or the p of this permit. Signature: Print Name: es not ce o esume to giv am a ority to olate or cancel the provisions of any other state or local laws regulating c„.1..t.o3i.gt and obtain this electrical permit and agree to the conditions on the back RO17L Date: /// /F //0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0896 Printed: 11 -18 -2010 PERMIT CONDITIONS Permit No. EL10 -0896 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL10 -0896 Printed: 11 -18 -2010 CITY OF TUKW�1 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. EL.10- .Q S 9 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Ass ssor's Tax No.: Site Address: (�O��Y► 1°:✓ © G? �� <oite Number: Tenant Name: !/ e New Tenant: Property Owners Nam- Segale Properties / Mailing Address: P 0 Box 88028 Tukwila Floo- ❑ Yes No WA 98138 City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: Bob Rau Mailing Address: 15321 105th Ave Ct E E -Mail Address: bob @rctrueline.com Day Telephone: Puyallup City Fax Number: (253) 377 -7111 WA State (253) 845 -4652 98374 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: 15321 105th Ave CT E _ c1, Contact Person: Bob Rau E -Mail Address: bob @rctrueline.com Contractor Registration Number: RCTRULC038QG Puyallup WA City State Day Telephone: (253) 377 -7111 Fax Number: (253) 845 -4652 98374 Zip Expiration Date: 11/01/2012 Valuation of Project (contractor's bid price): $ - S'eOo . Oa /e-1 Scope of Workers lease pro e detailed information): Will service be a red? ❑ Yes Type of Use: Cam. 467w- 11el21i C Type of work: ❑ New No %uuu Ad ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light 1jj'mcc.Cr� g re than 50 amps? DG� te-ct Yes ❑ No ❑ Service Change ❑ Fire Alarm H:Wppltcatmns\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Appltcanon.doc bh Page 1 of 2 Remodel ❑ Telecommunication 0 /Tenant Improvement Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: %0 w % / - 4 Gc— Day Telephone: (253) 377 -7111 Puyallup City :107". R E TRIC;i� .! TOR: "PZ Date: 1/-f- /a Mailing Address: 15321 105th Ave Ct E State 98374 Zip IDate Application Accepted: U Date Application Expires: 44_1 ( Staff Initials: H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Electncal Permit Apphcation.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0222049011 Permit Number: EL10 -0896 Address: Status: PENDING Suite No: Applied Date: 11/08/2010 Applicant: SEGALE PROPERTIES Issue Date: Receipt No.: R10 -02244 Payment Amount: $223.13 Initials: WER Payment Date: 11/08/2010 10:15 AM User ID: 1655 Balance: $0.00 Payee: R C TRUELINE CORPORATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3301 223.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 178.50 000.345.832.00.00 44.63 Total: $223.13 doc: Receiot -06 Printed: 11 -08 -2010 • .„ - INSPECTION-RECORD.-- . . Retain a copy with permit INSPE TION NO. . . PERMIT NO. ■ . CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila. VVA 98188 p... . (206) 431-36 Permit Inspection Request Line (206) 431-2451 ,. Project: Type of Inspection: Address: Date Called: Special Instructions: il Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: (;)Lfialo45 110)( 4:11.461AM fl REINSPECTION FEE REQUIRED. Prior to next inspectio . fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING D IVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 e PERMIT NO. Project: ..56.4 � Type of Inspection: 2/00 Address: Date Called: Special Instructions: Date Wanted: 1///9 �.: p.m. Requester: / Phone No: Approved per applicable codes. Corrections required prior to approval: COMMENTS: - RFQvi I) o'i Mau .5eizkit c4 �,J -r tl Dtsco44e -6-5j Date: r,1[//I a Vi i n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit tuo-071(0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: PP--OP Type of Inspection: 'if-00 Address: Date Called: Special Instructions: Date Wanted: / 2' 0 .r p.m. Requester: Phone No: ❑ Approved perapplicable codes. Corrections required prior to approval. COMMENTS: 0 x - - -TrAitif A 045 444p (AJrIZ i A!aif : thf56iz Ill („04 /t 3 &JV r-dood6-D iA104.0 1)6 0A-r° Inspector: Date: F1i Zi /e) n REINSPECTION FEE REQUIRED. Prior to next inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Pro'e . ( � � - Type of Inspection: 0 I S `7() CD Address: Date Called: /4-/e.-/-/6 Special Instructions: Date Wanted:�j a.m. /✓ 41 p.m Requester: ,0,/ Phone N��o::: :77.7// - hi/ Trj411477045 I KApproved per applicable codes. Corrections required prior to approval. COMMENTS: 9 4 --- IiihAVoKii66 - hi/ Trj411477045 re$ 2w Nip Loip � 6AotAtnici/60/6/ili 4 5110 P7 416c El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be ,paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Date: Receipt No.: Date: C �y • `', ♦A 5 ® COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0896 DATE: 11 -08 -10 PROJECT NAME: SEGALE PROPERTIES SITE ADDRESS: S 200TH ST & FRAGER RD X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: G� uuiiding n Public Works n Fire Prevention Structural n Planning Division ❑ Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 -09 -10 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12 -07 -10 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R -C TRUE LINE CORPORATION 2538458875 15321 105Th Ave Ct E Puyallup WA 98374 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601828382 Active RCTRULC038QG Electrical Contractor 11/7/1997 11/7/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRUEL**035KH TRU LINE LINE E Electrical Contractor General Unused 5/8/1997 5/8/1999 Archived Master Electrician INFORMATION License RAU'RRH967C3 Name RAU, ROBERT H Status Active Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H Violation Amount 01/01/1980 8/10/2009 RAU, CARLOTTA ELECTRICAL CITATION 01/01/1980 $250.00 RAU, ROBERT H Agent 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 445594C 11/01/1997 Until Cancelled $4,000.00 06/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00414 8/10/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 11/18/2010 1' —o" 1 8 8' -0" 3 LOADING INFO FILTER TRAILIER 27 HP PUMP MOTOR = 25.2 KW X 125 % = GFI DEDICATED OUTLET GFI DEDICATED OUTLET LIGHTS TOTAL KW TOTAL AMPERAGE 150 KW 31.5 KW 1.2 KW 1.2 KW .2 KW 184.1 KW 221.5 AMPS 500 MCM CU CABLE BUSS THROUGH 12 X 12 GUTTERS 30 amp Rain Tight fused disconnect Fused for 5 amp 480 5 KVA CONTROL TRANS POWER FEED TO 120 BREAKER BOX 6' 4" # 6 CU TAP CONDUCTORS • 4' -0" FUTURE 1 5HP 6'— 4' —1 " 10' — # 6 MINIMUM GROUND WIRE TO TWO GROUND - -I { RODS SET MINIMUM OF 1= I I (— TEN FEET APART 3 -750 MCM AL 1 -1 /0 AL FROM CUSTOMER OWNED OIL FILLED TRANFORMER FED FROM PRIMARIE METERED SYSTEM FRONT SIDE LAYOUT TESC FOND 4 POWER BOARD 3 5 3/0 TAP CONDUCTORS 3 -250 MCM AL 1 -4/0 AL 1 - #4 CU GRD TO FILTER TRAILER 4 [pi I 1 =1 I 1 1 1-1111--_-1 1- 11 ='1 I 1 ='I 11 =1 I I '7=1 1 i-1 i I -11 Imo' I I I -, II —I I 1 =1 I I- 1�'ermit No. 11� = "— Plan review approval Is subject to errors and omissions, Approval of construction documents does not authorize the violation of any adopted code or . a :. Receipt of approved F', ; ropy, ° °st owledged. %/ Ir, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: F;evisions will require a new plan submittal and may include additional plan review fees. FILE COPY BACK SIDE LAYOUT TESC POND 4 POWER BOARD 9(0 REVIEWED FOR -- COMPLIANCE WITH NFPA70 - NEC NOV 16 2010 of BUILD NG DIVISION By Date: City Of kwila BUILDING DIVISION UOO8'?(p D C RECEIVED NOV 08 2010 A PERMIT CENTER Bob Rau (253) 845 -8875 CeII (253) 377 -7111 Fax (253) 845 -4652 R - C TRUE LINE CORPORATION 15321 105th Ave CT E, Puyallup, WA 98374 RCTRULC038QG 6 bob @rctrueline.com w - J C7 w w 0 w m O 0 w a J (f) CL V) La CY N U Z Z 0 Z_ 0 ag,'yQ �w 0 w ce a� Ce 1— EL EC N z c? w 0 w 1- w cr w 0. 0 cr 0. w J w W a z W Q 1-0 J J Q f- z 4 0 Q 1 Q 0 w H w z 0 w CC LL) z 0 (1) 0 0 z INDUSTRIAL * COMMERCIAL * AGRICULTURAL * NATURAL RESOURCES PROJECT NUMBER: Ovil- <wo 2 = Z O (1) cc�a O0▪ Z F3:cna a O w J J � LaJ cn m w Z Ci- -0w z z O N a w a co N▪ . 4 co co • co Q ,0 Y N F- Q * � • * U LL1 > O Ou') cr Y r` o w N J UJ 4 Z 0 W iii w In I-- DRAWING NUMBER: WWW. SEGALEPROPERTIES. COM E7 SHEET :X OF: X