HomeMy WebLinkAboutPermit EL10-0905 - BOW LAKEBOW LAKE
18800 ORILLIA RD S
EL1 0-0905
Citylf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 3523049037
Address: 18800 ORILLIA RD S TUKW
Tenant Name: BOW LAKE
ELECTRICAL PERMIT
Permit Number: EL10 -0905
Issue Date: 12/02/2010
Permit Expires On: 05/31/2011
Owner:
Name: KING COUNTY
Address: 500 4TH AVE #500 KCAB , SEATTLE WA 98104
Contact Person:
Name: ANTHONY MOORE Phone: 253 661 -7181
Address: 1220 S 356 ST, STE A5 , FEDERAL WAY WA 98003
Contractor:
Name: FULLER ELECTRIC CO
Address: 37107 12 AV S , FEDERAL WAY WA 98003
Contractor License No: FULLEEI027BK
Phone:
Expiration Date: 01/12/2012
DESCRIPTION OF WORK:
PROVIDE 400A 480V TEMPORARY POWER SERVICE
Value of Electrical Work: NRES: $31,000.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected: $782.13
National Electrical Code Edition: 2008
Date: 11= ( V
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back
of this permit.
Signature:
Print Name:
Date: 12 /2i/0
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -9/09
ELI 0-0905 Printed: 12 -02 -2010
PERMIT CONDITIONS
Permit No. EL 10 -0905
* *ELECTRICAL **
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the
Electrical Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the
Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical
installations, Chapter 296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of
parts of the building, such equipment shall not be concealed until it has been inspected and
approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval
of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction.
Permits or related documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional
work permits. Where approved plans have been issued, revisions to the plans and additional review
may be required.
doc: EL -9/09
ELI 0-0905 Printed: 12 -02 -2010
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto://www.cLtukwila.wa.us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATIC
Site Address: 18800 Orillia Rd S
Tenant Name:
King County/ 0.0W Vn
Property Owners Name: King County - Attn Tom Creegan
Mailing Address: 201 S. Jackson St Rm 701
King Co Assessor's Tax No.: 352304903706
Suite Number: Floor:
New Tenant: ❑ Yes ..No
Seattle
City
WA 98104
State Zip
CON AC
Name: Anthony Moore
Mailing Address: 1220 S 356th Street Suite A5
E -Mail Address: Anthony @FullerElec.com
Company Name: Fuller Electric
Mailing Address:
Day Telephone:
Federal Way
City
Fax Number:
(253) 661 -7181
WA
State
(253) 661 -6956
98003
Zip
1220 S 356th Street Suite A5
Contact Person: Fuller Electric
E -Mail Address: Anthony @FullerElec.com
Contractor Registration Number: FULLEEI027BK
Federal Way WA
City State
Day Telephone: (253) 661 -7181
Fax Number: (253) 661 -6956
Expiration Date: 01/12/2012
98003
Zip
Valuation of Project (contractor's bid price): $ 31,000
Scope of Work (please provide detailed information): Provide 400A 480V temporary power service
Will service be altered? ❑ Yes m No
Type of Use: Temporary power for construction activities
Type of work:
❑ New ❑ Addition
❑ Low Voltage ❑ Generator
Property Served by:
• Puget Sound Energy
❑ Seattle City Light
Adding more than 50 amps? 0 Yes ❑ No
❑ Service Change
❑ Fire Alarm
H: Applications,Forms- Applications On Line`2010-Applicationa7 -2010 - Electrical Permit Application.doc
bh
Page 1 a?.
❑ Remodel ❑ Tenant Improvement
❑ Telecommunication m Temporary Service
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured/mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
1.2PERMITA LICATIONiNO ES
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
t HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: A t •TrHO J' f MooRE
Mailing Address: l 2 lo 5. 3 5('& 54- 0X45
Date Application Accepted:
ko Io
Day Telephone:
�ebElA1. WAY
City
Date: HP 1 fio
253 Wel 7181
vJ►1J ggOo3
State Zip
Date Application Expires:
VJ
Staff Initials:
J
H: Applications\Forms- Applications On Line12010 Applications \ -2010 • Electrical Permit Application.doc
bh
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 3523049037 Permit Number: EL10 -0905
Address: 18800 ORILLIA RD S TUKW Status: APPROVED
Suite No: Applied Date: 11/10/2010
Applicant: BOW LAKE Issue Date:
Receipt No.: R10 -02384
Payment Amount: $625.70
Initials: JEM Payment Date: 11/29/2010 01:50 PM
User ID: 1165 Balance: $0.00
Payee: GREGORY FULLER, FULLER ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 519284
ACCOUNT ITEM LIST:
Description
625.70
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 625.70
Total: $625.70
doc: Receiot -06 Printed: 11 -29 -2010
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 3523049037
Address: 18800 ORILLIA RD S TUKW
Suite No:
Applicant: BOW LAKE
RECEIPT
Permit Number: EL10 -0905
Status: PENDING
Applied Date: 11/10/2010
Issue Date:
Receipt No.: R10 -02266
Initials: JEM
User ID: 1165
Payment Amount: $156.43
Payment Date: 11/10/2010 09:09 AM
Balance: $625.70
Payee: FULLER ELECTRIC, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1236 156.43
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.00 156.43
Total: $156.43
doc: Receipt -06 Printed: 11 -10 -2010
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
fuo-ocioc
Project: 614 Pa
Type of Inspection:
®D
Address: f o0 afko,iiiii-Date
Called:
Special Instructions:
Date Wanted:
/2
a. m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
(ficfkalokb mot:
--r/lAts
Inspector 14
Date: a/oil/0
F-7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
flAo-00.1*
Project:
v0 l-teir4e
Type of Inspection:
Address:
Date Called:
Special Instructions:
Date Wanted:
/
/ ( T
�7 ,p
Requester:
`
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
-sly@?0,2T- AP-dirtn(.41415 oar- ptidet._
t46el SeC-A-OrtS led To (4 tCA
Inspector: / Ill A
f
Date: /7/07/'O
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
(00-07K
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4 1 -3670
Permit Inspection Request Line (206) 431 -2451
Project: 50141 C J' i
Type of Inspection:
Date Called:
"t610719°2-
Address:
1 nvo ®r{ti.i,k
Special Instructions:
..
Date Wanted:
/
a'/ 03
p.m.
Requester:
ff
Phone No:
IAApproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
D
4
• cAlMou 5c-oc&
Ahrr-63: 64,sou rumTvfri IA)
-rRq-r PArJFt, j
$O vol-1 P
207 JAL-r PISlo iA16C13 Wirt,
K A-iv/A/65-- veyv imp
.°7-v, UJ y-
Inspector:
5\1A)
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: a/03/10
/1. PERMIT MORD COPIA
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL10 -0905 DATE: 11/10/10
PROJECT NAME: BOW LAKE
SITE ADDRESS: 18800 ORILLIA RD S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPA TMENT vivo
uilding Division
Public Works ❑
Fire Prevention
Structural
n
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/16/10
Complete [IA
Comments:
Incomplete n
Not Applicable
El
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route Structural Review Required n No further Review Required n
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 12/09/10
Approved ❑ Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeoproter Friendly Page
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
FULLER ELECTRIC INC
2536617181
37107 12Th Ave S
Federal Way
WA
98003
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
601840365
Active
FULLEEI027BK
Electrical Contractor
1/12/1998
1/12/2012
General
Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
FULLEE "088NE
FULLER
ELECTRIC
Electrical
Contractor
General
Unused
8/5/1992
8/5/1998
Archived
FULLEE*105NL
FULLER
ELECTRIC
Electrical
Contractor
General
Unused
8/13/1990
8/13/1992
Archived
Electrical Administrator INFORMATION
License FULLEPA035NZ
Name FULLER, PATRICIA ANN
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
FULLER, GREGORY C
Violation Amount
01/01/1980
5/4/2009
FULLER, PATRICIA ANN
ELECTRICAL CITATION
01/01/1980
$250.00
S C E B SERVICES INC
Agent
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
CBIC
SB2906
01/01/1998
Until Cancelled
$4,000.00
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
EHOSJ00357
5/4/2009
19.28.161 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https: // fortress .wa.gov /lni/bbip /Print.aspx 12/02/2010
FILE COPY
Pent* No. FAQ-6'\c
Plan review approval Is stbjedto and
Approval of constniction , * does not
tics violation of any adopted code �r oidinamoe.
of approved Reld Copy and
By, ,i'f7
/0f21(26
COMPLIANCE
70 -NEC
2 4 2010
ila
VISION
City Orltwiia
BUILDING DIIyISION
shall be mad to the scope
of work without prior approval of
Tukwila Building D iision.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
3j1kAKE T0
KI N Cr GOt f
sac) LM -t>ads ' , s cN
SEF RATE PERMIT
REQUIRED FOR
Mechanical
O elect
ta Plumbing
Et Gas PpIrg
City of Tukwila
LSt ` oING DIVISION
FcJkt- Flec..4-,
6 Fu Lite-
'�.7 41-3-133g
- 3
rej
48o v&t+- TeeP PoL'_
Lya;
30FT
CLASS
3 POLE
2 1/2 PVC
(3) 250 XHHW
AL
LYDIG'S TRAILERS
1 1/4 PVC
(4) # 2 XHHW
AL WIRE
#lo Gut (04p
-rvn Leo ac
iqo cam- CrAD
f0�200A
210 FT TO TIRE WASH
1 1/4 (4) # 2 XHHW AL
190 FT
TO TRAILERS
400A
480V
PSE
CT
225A
480V
MLO
60/3
90/3
90/3
200A
FUSED
DC
N -3R
200A
FUSED
DC
N -3R
6X6 x 24ft
pressure treat d
REVIEWED FOR
COMPLIANCE WI
NFPA 70 - NEC
75KV
TR
75KV
TR
2 1/2 PVC
250 XHHW
AL
w/ 414 G,(. &V'
? M.
1 1/4 PVC
W r_� # 2 THHN CU
Clot
W S Cut WO
SIR- 10 A
NOV 24 2010
City of Tukwila
BUILDING DIVISIO
(4) 5/8 GRD RODS
200A
trailer
Panel
200A
trailer
Panel
RECEIVED
CITY OF TUKWILA
NOV 10 2010
PERMIT CENTER
Pa
LOAD CALCULATIONS FOR "PANEL Pg
BASED ON THE 2008 NEC
CALCULATED LOAD ( NEC 215.5 )
LI
10,638 VA
CALCULATED LOAD WITH DEMAND FACTORS ( NEC 215.5 )
GENERAL LOAD 1,518 VA
RECEPTACLE LOAD (NEC TABLE 220.44)
1ST 10,000W 0 VA
CONTINUOUS LOAD (NEC 215.2)
PLUS 25% (L I , L2, L3)
MOTOR LOAD (NEC 430.24)
PLUS 25% OF LARGEST MOTOR
KITCHEN LOADS (NEC 220.56)
L1(OX1)=
L2(OX1)=
L3 (0X1)=
TOTAL BALANCED LOAD (3- PHASE)
TOTAL BALANCED LOAD (1- PHASE)
TOTAL UNBALANCED LOAD (1- PHASE)
NEUTRAL LOAD
LINE AMPS BALANCED (3- PHASE)
LINE AMPS BALANCED (1- PHASE)
LINE AMPS UNBALANCED (1- PHASE)
TOTALS
ADJUSTMENT FACTOR
TOTAL DESIGN LOAD
VOLTAGE DROP CALCULATIONS
Three Phase
Voltage Drop %
0 VA
0 VA
9,120 VA
1,140 VA
0 VA
7,218 VA
822 VA
3,738 VA
60.1 A
7.9 A
31.2 A
99.2 A
0.0 A
99.2 A
L2
6,900 VA
2,340 VA
0 VA
0 VA
0 VA
4,560 VA
1.140 VA
0 VA
7218 VA
822 VA
0 VA
60.1 A
7.9 A
0.0 A
68.0 A
0.0 A
68.0 A
NEC 220.61(A)
L3 NEUTRAL'
0 VA
6,078 VA
1,518 VA
0 VA
0 VA
0 VA
4,560 VA
1,140 VA
0 VA
7218 VA
0 VA
0 VA
60.1 A
0.0 A
0.0 A
60.1 A
0.0 A
(2X60'1. X0.2530RX99.2A +1,000X0.866) =2.6VD
( 2.6 VD + 208 V X 100 ) = 1.3 % VD
HARMONIC CURRENT CALCULATION ( NEC 310.15 (B) 4 (C) & NEC TABLE 310.15 B (2) A )
( Harmonic Load 0 VA+ Connected Load 23,616 VA) X 100 = 0 %
Harmonic Load Does Not Exceed 50%
FAULT CURRENT CALCULATIONS
Available Fautt Current at Starting Point (( 35,000 AFC X 1.00 UA ) + 152 MC ) = 35,152 AFC
Conductor Factor CF - Formula ( 1.732 X 60 L X 35,152 AFC ) + ( 4,678 C X 1 N X 208 V) = 3.754 CF
Conductor Multiplier CM - Formula (1) + (1 + 3.754 CF ) = 0.210 CM
Conductor Let -Through Current CLC - Formula ( 35,152 AFC X 0.210 CM ) = 7,382 CLC
A - Amps
AFC - Available Fault Current
C - Conductor Constant
CF - Conductor Factor
CLC - Conductor Let -Through Current
CM - Conductor Muftipiler
L - Length of Conductor
MC - Motor Contribution
N - Number of Conductors Per Phase
R - Resistance
UA - Utility Adjustment 1.1
V - Voltage
VA - Von Amps
VD - Voltage Drop
• Line to Line Load Excluded
Prepared With Panel 2008 Software - Copyright Durand & Associates - www.durandassociates.com
60.1 A
0 VA
0.0 A
0.0 A
0.0 A
CIRCUIT DIRECTORY PANEL - P2.
CIR
DESCRIPTION
DESCRIPTION
CIR -'
1
LIGHTS
L1
HVAC
2
3
RECEPTALES
L2
HVAC
4
5
RECEPTALES
L3
HVAC
6
7
RECEPTALES
L1
HVAC
8
9
RECEPTALES
L2
10
11
LIGHTS
L3
L1
12
13
14
15
L2
16
17
L3
18
19
L1
20
21
L2
22
23
L3
24
25
L1
26
27
L2
28
29
L3
30
31
L1
32
33
L2
34
35
L3
36
37
L1
38
39
L2
40
41
L3
42
REVIEWED FOR
COMPLIANCE WITH
NFPA 70 - NEC
NUv 2 4 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
NOV 10 2010
PERMIT CENTER
CIRCUIT DIRECTORY PANEL P1
CIR
DESCRIPTION
DESCRIPTION
CIR
1
LIGHTS
L1
HVAC
2
3
RECEPTALES
L2
HVAC
4
5
RECEPTALES
L3
HVAC
6
7
RECEPTALES
L1
HVAC
8
9
RECEPTALES
L2
10
11
LIGHTS
L3
L1
12
13
14
15
L2
16
17
L3
18
19
L1
20
21
L2
22
23
L3
24
25
L1
26
27
L2
28
29
L3
30
31
L1
32
33
L2
34
35
L3
36
37
L1
38
39
L2
40
41
L3
42
LOAD CALCULATIONS FOR 'PANEL P1'
BASED ON THE 2008 NEC
L1 L2
CALCULATED LOAD ( NEC 215.5) 10,638 VA 6,900, VA
CALCULATED LOAD WITH DEMAND FACTORS ( NEC 215.5 )
GENERAL LOAD 1,518 VA
RECEPTACLE LOAD (NEC TABLE 220.44)
1ST 10,000W 0 VA
CONTINUOUS LOAD (NEC 215.2)
PLUS 25% (Lt, L2, L3)
MOTOR LOAD (NEC 430.24)
PLUS 25% OF LARGEST MOTOR
KITCHEN LOADS (NEC 220.56)
11(0X1)=
12 ( 0 X 1 ) =
L3 ( 0 X 1 )_
TOTAL BALANCED LOAD (3- PHASE)
TOTAL BALANCED LOAD (1- PHASE)
TOTAL UNBALANCED LOAD (1- PHASE)
NEUTRAL LOAD
0 VA
0 VA
9,120 VA
1,140 VA
0 VA
7,218 VA
822 VA
3,738 VA
LINE AMPS BALANCED (3- PHASE) 60.1 A
LINE AMPS BALANCED (1- PHASE) . 7.9 A
LINE AMPS UNBALANCED (1- PHASE) 31.2 A
TOTALS 99.2 A
ADJUSTMENT FACTOR 0.0 A
TOTAL DESIGN LOAD 99.2 A
VOLTAGE DROP CALCULATIONS
Three Phase
Voltage Drop %
NEC 220.61(A)
L3 NEUTRAL'
6,078 VA 0 VA
2.340 VA 1,518 VA
OVA OVA
0 VA
0 VA
0 VA
0 VA
4,563 VA 4,560 VA
1,140 VA 1,140 VA
0 VA
7,218 VA
822 VA
0 VA
60.1 A
.7.9 A
0.0 A
68.0 A
0.0 A
68.0 A
0 VA
7,218 VA
0 VA
0 VA
60.1 A
0.0 A
0.0 A
(2X60'LX0.2530RX99.2A +1,000X0.866) =2.6VD
( 2.6 VD + 208 V X 100 ) = 1.3 % VD
HARMONIC CURRENT CALCULATION ( NEC 310.15 (B) 4 (C) & NEC TABLE 310.15 B (2) A )
( Harmonic Load 0 VA 1- Connected Load 23,616 VA ) X 100 = 0 %
Harmonic Load Does Not Exceed 50%
FAULT CURRENT CALCULATIONS
Available Fault Current at Starting Point (( 35,000 AFC X 1.00 UA ) + 152 MC ) = 35,152 AFC
Conductor Factor CF - Formula ( 1.732 X 60 L X 35,152 AFC ) + ( 4,678 C X 1 N X 208 V) = 3.754 CF
Conductor Multiplier CM - Formula (1) + (1 + 3.754 CF) = 0.210 CM
Conductor Let - Through Current CLC - Formula ( 35,152 AFC X 0.210 CM ) = 7,382 CLC
A - Amps
AFC - Available Fault Current
C - Conductor Constant
CF - Conductor Factor
CLC - Conductor Let -Through Current
CM - Conductor Multiplier
L - Length of Conductor
MC - Motor Contribution
N - Number of Conductors Per Phase
R - Resistance
UA - Utility Adjustment 1.1
V - Voltage
VA - Volt Amps
VD - Voltage Drop
• Line to Line Load Excluded
Prepared With Panel 2008 Software - Copyright Durand & Associates - www.durandassociates.com
60.1 A
0.0 A
60.1 A
0 VA
0.0 A
0.0 A
0.0 A
REVIEWED .FOB
COMPLIANCE WIT
- NC
Icy 242010
H
City of•Tukwila
BUILDING DIVISIO
CITY OF TUKWILA
NOV 10 2010
PERMIT CENTER
.5
?-atAca- C.4 144.,
6-* PS E 1)0(1. ift,-5 0-4 0,•- i_doV /■16044
• • ":"T"'
City of
JILDI
RECEIVE
tyi
LLj 14
o tAe Lt./
t s4 (2) 6",(645x P6
4-6v Iv 04 v- 4V41*-4,, t 46-4 Lsekv