HomeMy WebLinkAboutPermit EL10-0915 - TESC POND #2TESC POND #2
APN: 0222049033
EL1O-0915
Parcel No.: 0222049033
Address:
Olaf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.ci.tukwila.wa.us
Tenant Name: TESC POND #2
ELECTRICAL PERMIT
Permit Number: EL10 -0915
Issue Date: 11/29/2010
Permit Expires On: 05/28/2011
Owner:
Name: LA PIANTA LLC
Address: PO BOX 88028 , TUKWILA WA 98138
Contact Person:
Name: BOB RAU
Address: 15321 105 AV CT E , PUYALLUP WA 98374
Contractor:
Name: R -C TRUE LINE CORPORATION
Address: 15321 105 AV CT E , PUYALLUP WA 98374
Contractor License No: RCTRULC038QG
Phone: 253 377-7111
Phone: 253 845 -8775
Expiration Date: 11/07/2011
DESCRIPTION OF WORK:
INSTALL 200 AMP 3 PHASE 480 VOLT TEMP POWER AND CONTROL FOR PUMP SYSTEM.
CONNECT TO OWNER PROVIDED OIL FILLED TRANSFORMER ON PRIMARY METER SYTEM.
Value of Electrical Work: NRES: $5,000.00
RES: $0.00
Type of Fire Protection: UNKNOWN
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected: $223.13
National Electrical Code Edition: 2008
Ve}"(._
Date: / /%f
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of wort ,Yam authorized to sign and obtain this electrical permit and agree to the conditions on the back
of this permit.
Signature:
Print Name: `� vl 4 l/ l s 4174--kn CCvl
Date:
/ //z l( /�
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -9/09
EL10 -0915 Printed: 11 -29 -2010
PERMIT CONDITIONS
Permit No. EL 10 -0915
* *ELECTRICAL **
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the
Electrical Inspector at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the
Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical
installations, Chapter 296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of
parts of the building, such equipment shall not be concealed until it has been inspected and
approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval
of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction.
Permits or related documentation that presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional
work permits. Where approved plans have been issued, revisions to the plans and additional review
may be required.
doc: EL -9/09
EL10 -0915 Printed: 11 -29 -2010
CITY OF TUKV
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
•
Electrical Permit No. CUD l
Project No. .,,..
(For 'o ice use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Pk-4 j `- At", e-
?SSG te, y Jz
King Co ssess is Ta No.: (72-2/2- c -t l D
�+ 7
Site Address: ! uG� Ce e e 1um "ber: Floor:
Tenant Name: ' �G — / i . S New Tenant: ❑ Yes No
Property Owners Name: ! regale Properties
Mailing Address: P 0 Box 88028
Tukwila
WA 98138
City
State
Zip
CONTACT PERSON —Who do we contact when your permit is ready to be issued
Name: Bob Rau
Mailing Address: 15321 105th Ave Ct E
E -Mail Address: bob @rctrueline.com
Day Telephone: (253) 377 -7111
Puyallup WA 98374
City State
Fax Number: (253) 845 -4652
Zip
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
15321 105th Ave CT E
Puyallup
Contact Person: Bob Rau
WA 98374
City State
Day Telephone: (253) 377 -7111
E -Mail Address: bob @rctrueline.com Fax Number: (253) 845 -4652
Contractor Registration Number: RCTRULC038QG Expiration Date: 11/01/2012
Zip
Valuation of Project (contractor's bid price): $
Sco.e of Work (please provide detailed information).
evOO r co.O
Will service be altered? G Yes it No A. . ing more than 50 amps? Yes ❑ No
Type of Use: �-�j2
Type of work:
❑ New ❑ Addition
❑ Low Voltage ❑ Generator
Pro ert erved b :
Puget Sound Energy
❑ Seattle City Light
❑ Service Change
❑ Fire Alarm
H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application doc
bh
Page 1 of 2
❑ Remodel
❑ Telecommunication
❑ Tenant Improvement
emporary Service
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $152.85
(including an attached garage)
❑ Garages, pools, spas and outbuildings $81.90 ea
❑ Low voltage systems
(alarm, furnace thermostat) $59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added/altered circuits)
❑ Service change with added/altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added/altered without service change $54.60
(up to 5 circuits)
❑ Circuits added/altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured /mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $10.50 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELFfT3CA C NT R:
Signature:
Print Name:
p l
Mailing Address: 15321 105th Ave Ct E
Date Application Accepted:
It
PA.
Day Telephone:
Puyallup
City
Date Application Expires:
Date: / l —
(253) 377 -7111
98374
Dc-1111 II
State
Zip
HAApplications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc
bh
Page 2 of 2
Staff Initials:
1
of Tukwila,
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: //www. ci. tukw ila. wa. us
SET RECEIPT
Copy Reprinted on 11 -12 -2010 at 10:54:39 11/12/2010
RECEIPT NO: R10 -02281
Initials: JEM
Payment Date: 11/12/2010
User ID: 1165 Total Payment: 582.76
Payee: R. C. TRUE LINE CORPORATION
SET ID: S000001447 SET NAME: Temporary Set
SET TRANSACTIONS:
Set Member
EL10 -0915
EL10 -0916
EL10 -0917
TOTAL:
Amount
223.13
223.13
136.50
136.50
TRANSACTION LIST:
Type Method Description Amount
Payment Check 3302 582.76
TOTAL: 582.76
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR 000.322.101.00.0
ELECTRICAL PLAN - NONRES 000.345.832.00.0
493.50
89.26
TOTAL: 582.76
INSPECTION RECORD
INS
Retain a copy with permit OBI
CTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 437 -3670"
Permit Inspection Request Line (206) 431 -2451
Project: �C ? 4 2
Type of Inspection:
2/00
Address:
Date Called:
Special Instructions:
Date Wanted:
AZ
t f z
a.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
rrA)41v
Inspector:
Date:
ry211�
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -3670
Project:
Type of Inspection:
Address:
Date Called:
42 -/e( `
Special Instructions:
Date Wanted:
la- 05 -��
a.m.
p.m.
Requester:
D c \ -MA
—
Phone No:
0
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
1
Itge '9 EK/®45
Po PS
64drJ9in6t� f 6046/Afti
Inspector: d A�� 1>e*1
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 12/'
Receipt No.:
Date:
* dEHMIT CdORD COPV
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL10 -0915 DATE: 11/12/10
PROJECT NAME: TESC POND #2
SITE ADDRESS: APN: 0222049033
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DE�PART�MEN�TS:
BuTldng- Division' Y�
Public Works
Fire Prevention
Planning Division
nStructural n Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11 /16/10
Complete cg]
Comments:
Incomplete ❑
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Building
Please Route
REVIEWER'S INITIALS:
Structural Review Required n No further Review Required n
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 12/14/10
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Piper Friendly Page
Electrical Contractor
A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
R -C TRUE LINE CORPORATION
2538458875
15321 105Th Ave Ct E
Puyallup
WA
98374
Pierce
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
601828382
Active
RCTRULC038QG
Electrical Contractor
11/7/1997
11/7/2011
General
Unused
ther Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
TRUEL**035KH
TRU
LINE
E
LINE
Electrical
Contractor
General
Unused
5/8/1997
5/8/1999
Archived
Master Electrician INFORMATION
License RAU *RRH967C3
Name RAU, ROBERT H
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
RAU, ROBERT H
Violation Amount
01/01/1980
8/10/2009
RAU, CARLOTTA
ELECTRICAL CITATION
01/01/1980
$250.00
RAU, ROBERT H
Agent
01/01/1980
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
Et INDEM CO
445594C
11/01/1997
Until Cancelled
$4,000.00
06/15/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
EREEB00414
8/10/2009
19.28.161 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https: // fortress .wa.gov /lni/bbip /Print.aspx 11/29/2010
LA PIANTA TUKWILA SOUTH
TEMP POWER
SEGALE PROPERTIES
LOADING INFO
27 HP PUMP MOTOR = 25.2 KW X 125% =
27 HP MOTOR @ 100 % =
GFI DEDICATED OUTLET
GFI DEDICATED OUTLET
LIGHTS
6' -4"
30 amp Rain Tight
fused disconnect
Fused for 5 amp 480
5 KVA CONTROL TRANS
POWER FEED TO
120 BREAKER BOX
3/0 CU CABLE BUSS
THROUGH 12 X 12 GUTTER
1' -0"
1
8"
#6CUTAP
# 3 CU TAP CONDUCTORS
4' -0"
6' -6"
4' —1 "
10' -0"
_' -'III' -1 ;7-
# 6 MINIMUM GROUND
WIRE TO TWO GROUND
RODS SET MINIMUM OF
TEN FEET APART
SEPARATE PERMIT
REQUIRED FOR:
IST Meehan
0 Electrical
l
Plumbing
Gas P
BUILD
City of Tukwila
� ING DIVISION
REVISIONS
No changes snail be made to the scope
of work without prior approval of
Tukwila Building Divisicn.
PLOT: Ret';slons will require a n 5n^f plc, submit I
3 -250 MCM AL
1 -4/0 AL
FROM CUSTOMER OWNED
OIL FILLED TRANFORMER
FED FROM PRIMARIE METERED
SYSTEM
1
FRONT SIDE LAYOUT
TESC POND 2 POWER BOARD
2
3
TOTAL KW
TOTAL AMPERAGE
1 4
31.5 KW
25.2 KW
1.2 KW
1.2 KW
.2 KW
59.3 KW
71.5 AMPS
5
I— —1 r
I I 1 1 11 1
I I 1 1 11 1
11 1 LJLJ�
I I 1 r-
L _1 I 1
J
IIII —�
111 -11 1-
I1•
1 , I ! 1 = ! '=
; - TPian- reV►iew approval is subject to errors and omissions.
Approval of construction documents does not authorize
Vic violation of any adopted code or ordinance. Receipt
of approved Field Cop and co ' ions is acknowledged:
By. iO4 ti c 4 (�
Date: (2 ?
6
REVIEWED F014
COMPLIANCE WITH
NFPA 70 - NEC
NUV 2 4 2010
City of
BUILDING
AAA
kwila
!VISION
FILE COPY
mit No. . L1®' .
BACK SIDE LAYOUT
TESC POND 2 POWER BOARD
/5" +new soup<��✓�./?.G.�
5
City Of'ilukwita
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
NOV 12 2010
PERMIT CENTER
Bob Rau
CeII (253) 377 -7111 Fax (253) 845-4652
R - C TRUE LINE CORPORATION
15321 105th Ave CT E, Puyallup, WA 98374
RCTRULC038QG
bob@rctrueline.com
D
C
A
��In -offis
6
ww
J m
I-2
O C
zLL
Q
W1-F-
Z
owN
Ce
a =
v_lciz
z O
z D
O
W
m W
a�
i- ar
w
W
a.
0
cc
0
W
J
W
Ct�
W
z
z
W
0
1-
U
J
J
4
Z
4
4
J
4
PROJECT NUMBER:
DRAWING NUMBER:
E