HomeMy WebLinkAboutPermit EL10-0916 - TESC POND #3TESC POND #3 APN: 0222049033 EL1O-0916 Parcel No.: 0222049011 Address: r ^, Cil f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.ci.tukwila.wa.us Tenant Name: TESC POND #3 ELECTRICAL PERMIT Permit Number: EL10 -0916 Issue Date: 11/29/2010 Permit Expires On: 05/28/2011 Owner: Name: LA PIANTA LLC Address: PO BOX 88028 , TUKWILA WA 98138 Contact Person: Name: BOB RAU Address: 15321 105 AV CT E , PUYALLUP WA 98374 Contractor: Name: R -C TRUE LINE CORPORATION Address: 15321 105 AV CT E , PUYALLUP WA 98374 Contractor License No: RCTRULC038QG Phone: 253 377-7111 Phone: 253 845 -8775 Expiration Date: 11/07/2011 DESCRIPTION OF WORK: INSTALL 100 AMP 3 PHASE 480 V TEMP POWER AND CONTROL FOR PUMP SYSTEM. CONNECT TO OWNER PROVIDED OIL FILLED TRANSFORMER ON PRIMARY METER SYSTEM. Value of Electrical Work: NRES: $5,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $223.13 National Electrical Code Edition: 2008 Date: / / /d //d I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. 1 . . uthorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: (4t, Print Name: Date: / / 2?/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0916 Printed: 11 -29 -2010 PERMIT CONDITIONS Permit No. EL10 -0916 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL 10 -0916 Printed: 11 -29 -2010 CITY OF TUKWS Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us SITE LOCATION ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** ,, // King Co Assessor's Tax No.: r Site Address: 9� diu 5o.v/ h- C.9`4" Suite Number: Tenant Name: �� ../%� S Property Owners Na Segale Propertie Mailing Address: P 0 Box 88028 Tukwila Floor: New Tenant: ❑ Yes ❑ ..No WA 98138 Zip City State CONTACT PERSON --Who do we contact when your permit is ready to be issued Name: Bob Rau Mailing Address: 15321 105th Ave Ct E E -Mail Address: bob @rctrueline.com Day Telephone: (253) 377 -7111 Puyallup WA 98374 City State Fax Number: (253) 845 -4652 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: ,2G %rte �.�..� 15321 105th Ave CT E Puyallup / WA 98374 Zip Contact Person: Bob Rau City State Day Telephone: (253) 377 -7111 E -Mail Address: bob @rctrueline.com Fax Number: (253) 845 -4652 Expiration Date: 11/01/2012 Contractor Registration Number: RCTRULC038QG Valuation of Project (contractor's bid price): $5Ot/JO. 00 Scope of Work (please provide detailed information): Z l . � /00 / ,♦ S1 ✓d +r , . I / Will service be altered? ❑ Yes Type of Use: Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: c' Puget Sound Energy ❑ Seattle City Light 0 OGcJ —Gtr HI li 7- more tha 50 amps? ps? Yes etil ❑ No ❑ Service Change ❑ Fire Alarm H:\Applicanons\Porms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE S . OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O tl R EL , TVA CO 'T_; Its" Signature:_ AVON RD ER Print Name: Mailing Address: 15321 105th Ave Ct E I Date Application Accepted: 1 121 ( Z Date: // ` // • /0 Day Telephone: (253) 377 -7111 Puyallup City State 98374 Zip Date Application Expires: Oc .12111 Staff Initials: t / c. H:Wpplications\Forms- Applications On Lme\2010 Applications \7 -2010 - Electncal Permit Application.doc bh Page 2 of 2 Ci, of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://wwwci.tukwila.wa.us SET RECEIPT Copy Reprinted on 11 -12 -2010 at 10:54:39 11/12/2010 RECEIPT NO: R10 -02281 Initials: JEM Payment Date: 11/12/2010 User ID: 1165 Total Payment: 582.76 Payee: R. C. TRUE LINE CORPORATION SET ID: S000001447 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL10 -0915 EL10 -0916 EL10 -0917 TOTAL: Amount 223.13 223.13 136.50 136.50 TRANSACTION LIST: Type Method Description Amount Payment Check 3302 582.76 TOTAL: 582.76 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 493.50 89.26 TOTAL: 582.76 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 61n-oclq0 Project: "( e oi Type of Inspection: 2/ Address: Date Called: Special Instructions: Date Wanted: , �� % Requester: Re q Phone No: 14 Approved per applicable codes. a Corrections required prior to approval. COMMENTS: DX Inspector: n REINSPECTIONTFEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: (z z lro INSPECTION RECORD � t Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION .6- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project t Ak-D1r Type of Inspection: '2►''vCA �' v\ () Q Address: Der Called: V- Special Instructions: Date Wanted: a.m. - Requester: b C) �_.- CU P(5 •11 ,`1 l 1 1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 14' - 5tR 4 r et - A 1 rl i ki rfv'J5 (,Q JAip/A/4 & J oi'' - Di5c&J J PA-J NrIP5 Inspector: Date: / S /S d ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ��.r. »..�...,.�r�N. r-, �s�....- <,rt- „+,,..._- . >��,..Rre..,._�. r...,,. �a�, x_< H,.,. .......,.a�v�n�T,..•z�:�.c „,-., n,. --_w INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6,10-Dq* PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4 1 -3670 Permit Inspection Request Line (206) 431 -2451 Project: /�C �� Type of Inspection: 70°1 Address: Date Called: Special Instructions: Date Wanted: /W a.m: Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: 41,-1?F� ANYar9 Inspector: &04Lie Date: 437/0 REINSPECTION FEE REQUIRED. Prior to'next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT 0. CITY OF TUKWILA. BUILDING DIVISION , 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: �� # Type of Inspection: 7001 Addr ArlD ;St, Date Called: Spell instructions: Date Wanted: ©. a.m. p.m. Requester: a no Phone No: 24 3 377 PI/ Approved per applicable codes. 0 Corrections required prior to approval. / COMMENTS: ° 4D tii6q-04 Inspector: '':/[65‘itia\ Date: 2,/02110 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. � PERMITCOORD COMO PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0916 PROJECT NAME: TESC POND #3 SITE ADDRESS: APN: 0222049033 DATE: 11/12/10 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS. it'�� Bu ng 'vision Public Works Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/16/10 Complete t%1 Comments: Incomplete ❑ Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/14/10 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople P.,r, ter Friendly Page • Electrical Contractor A business licensed by LEI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R -C TRUE LINE CORPORATION 2538458875 15321 105Th Ave Ct E Puyallup WA 98374 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601828382 Active RCTRULC038QG Electrical Contractor 11/7/1997 11/7/2011 General Unused License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRUEL "035KHTRUE LINE Electrical Contractor General Unused 5/8/1997 5/8/1999 Archived Master Electrician INFORMATION License RAU'RRH967C3 Name RAU, ROBERT 1-1 Status Active Business Owner Information Name Role Effective Date Expiration Date RAU, ROBERT H Violation Amount 01/01/1980 8/10/2009 RAU, CARLOTTA ELECTRICAL CITATION 01/01/1980 $250.00 RAU, ROBERT H Agent 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY Et INDEM CO 445594C 11/01/1997 Until Cancelled $4,000.00 06/15/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00414 8/10/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 11/29/2010 D C A 1 2 30 amp (Rain Tight fused disconnect Fused for 5 amp 480 5 KVA CONTROL TRANS POWER FEED TO '120 BREAKER BOX 8' -0" 6' 4" 3 1 4 LOADING INFO 15P PUMP MOTOR = 13.9 KW X 125% _ GFI DEDICATED OUTLET GFI DEDICATED OUTLET LIGHTS #3 CU CABLE BUSS THROUGH 12 X 12 GUTTER 8" # 6 CU TAP CONDUCTORS FUTURE 1 5HP 4'-0" 6' -6" 4,— tf 10' -0" L1 1 1111 l lliil 11 �illl�;!II I III 4 -# 1 AL FROM CUSTOMER OWNED OIL FILLED TRANFORMER FED FROM PRIMARIE METERED SYSTEM REVISIONS No chances shall be made to the scope of wont without prior approval of Tukwila Building Division. NOTE: Revisions will require a new pi2n submittt t cm] may inc'ude additional plan re '^t+ r 1 _ 1 # 6 MINIMUM GROUND WIRE TO TWO GROUND RODS SET MINIMUM OF TEN FEET APART FRONT SIDE LAYOUT TESC POND 3 POWER BOARD 2 3 TOTAL KW TOTAL AMPERAGE 4 17.5 KW 1.2 KW 1.2 KW .2 KW 20.1 KW 24 AMPS r 5 1 -1 I--- n 11 1 1 11 I 11 1 1 11 1 11 1 L _1 __J _J 1 I L 1 111111111 ! I- 1 =1 1 ;111_ SEPARATE PERMIT REQUIRED FOR: ta Mechanical ❑ Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 11! 1! -11 !_ "1=111=-=-1 J 6 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NUV242010 AAA City of ;: , ila BUILDING ISION PI: Li A" ., i C O 1- III- 1I-- 1i1 -IlI- .�LIO� � Plan review approval is subject to errors and omisrinn . Approval of construction documents does not authr, th6 violation of any adopted code or ordinance. T: (r: t of approved Field Copy and conditio ,ps is aclmowle0 BACK SIDE LAYOUT TESC POND 3 POWER BOARD /97,7`' , N-ew so.,A c.e.d, /),e,_/, 5 By �. Date: /7/Z9 jD City Of Tukwila BUILDING DTVT :ION D C RECEIVED CITY OF TUKWLA NOV 12 2010 PERMIT CENTER Bob Rau Cell (253) 377 -7111 Fax (253) 845 -4652 (253) 845 -8875 R - C TRUE LINE CORPORATION 15321 105th Ave CT E, Puyallup, WA 98374 RCTRULC038QG bob@rctrueline.com a WO-014 6 V, W w ®. 0 cc 0 w QJJ 0 w CO 111 4 z W O 4 GC F U J J 4 1- z 4 U- 4 J 4 INDUSTRIAL • COMMERCIAL • AGRICULTURAL • NATURAL RESOURCES 0 PROJECT NU1ABER: U,1 0 w CO O z J J rn cc • 0 w J Z =o z� o w w °- O w O i— o WWW. SE GALEPROPERT IES. COM CC L CC .rrr W loam a DRAWING NUMBEIt E6 SHEET( Of X