Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0925 - PACIFIC COURT APARTMENTS - COMMUNITY BUILDING
PACIFIC COURT APTS C OMMUNITY BUILDING 4028 S 146 ST EL1 0-0925 Parcel No.: Address: Tenant Name: City* Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 0040000250 4028 S 146 ST TUKW PACIFIC COURT APTS - COMMUNITY BLDG Permit Number: EL10 -0925 Issue Date: 12/01/2010 Permit Expires On: 05/30/2011 Owner: Name: Address: Contact Person: Name: Address: HOUSING AUTH 600 ANDOVER PARK W , TUKWILA WA 98188 STEVEN NIEMI PO BOX 128 , BATTLE GROUND WA 98604 Contractor: Name: TRADESMEN ELECTRIC INC Address: PO BOX 128 , BATTLE GROUND WA 98604 Contractor License No: TRADEEI954R9 Phone: 360- 666 -1199 Phone: 360 - 666 -1199 Expiration Date: 12/29/2011 DESCRIPTION OF WORK: ELECTRICAL, FIRE ALARM, SECURITY PREWIRE, PHONE/DATA, TV, AND CAMERA INSTALLATION FOR A NEW COMMUNITY BUILDING AT THE EXISTING APARTMENT COMPLEX. Value of Electrical Work: Type of Fire Protection: NRES: $44,200.00 RES: $0.00 UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Fees Collected: $1,083.13 National Electrical Code Edition: 2008 Date: L l o l( V o ed this permit and know the same to be true and correct. All provisions of law and ordinances with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Print Name: c9--eve-vi / v 3-e441 Date: 1 Z /C)/ �f0 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0925 Printed: 12 -01 -2010 PERMIT CONDITIONS Permit No. EL10 -0925 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL10 -0925 Printed: 12 -01 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION p King Co Assessor's Tax No.: OO 4 bO0 - 0 ZS O Site Address: qc) l0 114�� 5f'e4� Tu.kW Suite Number: Tenant Name: T A.G4iL CA f .pr,,/.w'UMI New Tenant: Property Owners Name: 7 KM C of rl l y iCk WS 9 AVACIv dy Mailing Address: GOO 40101(Wer Potrk w 74.fr-w11R / 1444 901/ Pe Floor: ❑ Yes ❑ ..No City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: 5fet'C - n orn % (? r , 044,4 ZZCeth ) Day Telephone: C i) Q ^ (« Mailing Address: o0 . Q6 c (z 7 / ti(e. &rut44 G( gnoy City State Zip E -Mail Address: 9-eve etrixdafrue.,,ted 'c • Ct1 J+-1 Fax Number: &41-0-1 644— (/2v ELECTRICAL CONTRACTOR INFORMATION Company Name: F.O. ailing Address: I SoNc, tZ$ gq. Grateick &de- giro,/ City State Zip Contact Person: Y VD wit Day Telephone: &x`61 666-ail E -Mail Address: yv. f /Lc @ 41-.0 F teCJ / Vti .. con Fax Number: ( 6 is 6.6 ` C. 12 y Contractor Registration Number: Tr iliD €E1 9571 R 9 Expiration Date: 12(29 (2011 T r Dwie -si 14 ri et e_c lve, Valuation of Project (contractor's bid price): $ q1 Z00100 Scope of Work (please provide detailed information): FJ edit" o .I I T-�we f ttrm, $PC.Urt.i y Pnewkci Phone_ / DA, fa , TV I 4 rtdt Ca,�ur�a ��. S f lie, ,( h .r- Ck- /*IL 6:7410414'•1* �Y KtA; I01. a4- 11-c.. eYrt a /24 rfine,,vi a ye1&,e Will service be altered? Zr Yes ❑ No Type of Use: II%Gt.ict i 4.1f Type of work: . New ❑ Addition ❑ Service Change jg Low Voltage ❑ Generator a Fire Alarm Property Served by: ❑ Puget Sound Energy Seattle City Light H:Wpphcanons\Ponns- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Appltcation.doc bh Page 1 of 2 Adding more than 50 amps? Er Yes ❑ No ❑ Remodel ❑ Tenant Improvement at—Telecommunication V Temporary Service • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: C Print Name: 9 , -e (Ach Mailing Address: r, 0. 'x t Z3 Date: It/ rz /0 Day Telephone: &C)) /v f— (3.6(9 pcdJ -L� Citi rr 1 City �?4- Date Application Accepted: Date Application Expires: State Zip Staff Initials: kb/2_ H:VApphcanons\Forms- Applwanons On Lme\2010 Apphcanonsi7-2010 - Electrical Permit Apphcanon.doc bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0040000250 Permit Number: EL10 -0925 Address: 4028 S 146 ST TUKW Status: APPROVED Suite No: Applied Date: 11/15/2010 Applicant: PACIFIC COURT APTS - COMMUNITY BLDG Issue Date: Receipt No.: Initials: User ID: R10 -02404 JEM 1165 Payment Amount: $866.50 Payment Date: 12/01/2010 11:27 AM Balance: $0.00 Payee: STEVEN W NIEMI, TRADESMEN ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 311072 ACCOUNT ITEM LIST: Description 866.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 866.50 Total: $866.50 doc: Receiot -06 Printed: 12 -01 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0040000250 Permit Number: EL10 -0925 Address: 4028 S 146 ST TUKW Status: PENDING Suite No: Applied Date: 11/15/2010 Applicant: PACIFIC COURT APTS - COMMUNITY BLDG Issue Date: Receipt No.: R10 -02297 Initials: User ID: Payee: WER 1655 Payment Amount: $216.63 Payment Date: 11/15/2010 10:16 AM Balance: $866.50 STEVEN NIEMI TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 215161 ACCOUNT ITEM LIST: Description 216.63 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 216.63 Total: $216.63 doc: Receiot -06 Printed: 11 -15 -2010 INSPECTION RECORD Retain a copy with permit INSPE TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I2_, (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project:4i Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: 7 1I ape p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 97 1{ /11 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be . paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.' INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project• A_S. Aik6 • Type of Inspection: / Address: Date Called: Special In tructions: Date Wanted: , V Cap. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4).,<",t1 54-rXtri) r) Inspector: )14 15.61.1ex r r F7 REINSPECTIONIFEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: O5 it INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKINILA BUILDING DIVISION' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 „ Project: F. - ir i A A,....., 1-4.. WI) Type of Inspection: ...._ Address: 10,Z)i' .5* /f6 sr Date Called: Special Instructions: Date Wanted: Requester: Phone No: glApproved per applicable codes. D Corrections required prior to approval. COMMENTS: 9)/ Inspector: Date: Oida II 1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee miiStbe paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: - INSPECPION NO. INSPECTION RECORD Retain a copy with permit 6/1(M) PS PERMIT N�. / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 (L Project: A-c- (,o'.JRx Address: 10215. r (( 5r. Special Instructions: Type of Inspection: 70O/ Date Called: Date Wanted: Requester: 21(1 m. Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0/- t/4ii.t -13 P 61 L 7 Inspector: Date: 4-111 64469\ 02/111 tl n REINSPECTION FLE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. S INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project �-�J�i� A � Type of Inspection: ,� 3 7i3� % i f° Address: _ �� 5. lye 51 Date Called: lit: Zd" N:=ec, R.17-0,-mtv,AN PA, Special Instructions: Date Wanted: IQ� ®* / p.m. Requester: ((( Phone No: pApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: % i f° 69 > 4 4 J `. lit: Zd" N:=ec, R.17-0,-mtv,AN PA, 0 \ V -9C., G1/416, 4-01-s5 to .l ,-al od or Lv.ff p 1) Date: 0;110'4 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ‘-'140 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj¢ 6_4• AiP _ ! f a b .700/ Address: (t222P 5. /Y19 T''' Date Called: • Special Instructions: Date Wanted: /207 a.r� Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 04 c —s) P r PRtI( aIl� 4 ePJ -1ou$ Inspector: 6:Aec Date: n REINSPECTIOIV FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit tho-o?16 PERMIT NO. I� / CITY OF TUKWILA BUILDING DIVISION r- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 43173670 Permit Inspection Request Line (206) 431 -2451 Pro ec . C5 -, q fr T pe of Inspection: Y p 700 Address: Li@Zg' ,5 .t iit 6 5r. Date Called: Special Instructions: p. va uL& . Date Wanted: / /21.0 (m. lr'� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. / COMMENTS: Yik Inspector: c 11&ir efl\ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: I „ /Cn) r0 41P PAi COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0925 DATE: 11 -15 -10 PROJECT NAME: PACIFIC COURT APTS - COMMUNITY BLDG SITE ADDRESS: 4028 S 146 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: u ding Division Public Works n Fire Prevention Structural n Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-16-10 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S I���NNIITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -14 -10 Approved Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Peter Friendly Page Electrical Contractor A business licensed by MI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company TRADESMEN ELECTRIC INC 3606661199 Po Box 128 Battle Ground WA 98604 Clark Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602568514 Active TRADEEI954R9 Electrical Contractor 12/29/2005 12/29/2011 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TRADEEL950LC TRADESMEN ELECTRIC LLC Electrical Contractor General Unused 6/3/2005 6/3/2007 Out Of Business Electrical Administrator INFORMATION License NIEMIS'951C4 Name NIEMI, STEVEN Status Active Business Owner Information Name Role Effective Date Expiration Date NIEMI, STEVEN W Agent 12/29/2005 NIEMI, STEVEN W President 12/29/2005 NIEMI, RICHARD W Vice President 12/29/2005 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 WESTERN SURETY CO 69909112 12/23/2005 Until Cancelled $4,000.00 12/29/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type https: // fortress .wa.gov /lni/bbip/Print.aspx 12/01/2010 CIRCUITING SYMBOLS NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. —Is-- INDICATES GROUND WIRE. —\ INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) —3 RACEWAY STUB —OUT WITH BUSHING —► HOME RUN TO PANEL OR LOCATION NOTED —: CIRCUIT CONTINUATION U /10 JUNCTION BOX, CEILING /WALL m PULL BOX HANDHOLE e/r/V ---- UNDERGROUND UTILITY SERVICE — POWER, TELEPHONE & CABLE AS INDICATED P/74 OVERHEAD UTILITY SERVICE — POWER, TELEPHONE & CABLE AS INDICATED C -0 POWER POLE /GUY 4 4 etve its • i 0= os tm 0 METER POWER SYMBOLS DUPLEX RECEPTACLE 120V DOUBLE DUPLEX RECEPTACLE 120V DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE DOUBLE DUPLEX RECEPTACLE — GROUND FAULT CIRCUIT INTERRUPTER TYPE DEDICATED DUPLEX / QUAD RECEPTACLE DUPLEX RECEPTACLE SAFETY TYPE DUPLEX RECEPTACLE — ABOVE COUNTER: MOUNT +6" ABOVE COUNTER /SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE GFI DUPLEX RECEPTACLE ABOVE COUNTER: MOUNT +6" ABOVE COUNTER /SINK/ BACKSPLASH OR MOUNT +54" AFF AS APPLICABLE SINGLE RECEPTACLE 120V SPLIT SWITCHED DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH DEVICE AS INDICATED FLUSH MOUNTED CEILING RECEPTACLE PEDESTAL TYPE FLOOR BOX WITH DEVICES AS SHOWN FLUSH FLOOR POKE THROUGH — DEVICES AS INDICATED SPECIAL RECEPTACLE, NEMA /VOLTAGE AS INDICATED SPECIAL RECEPTACLE, NEMA /VOLTAGE AS INDICATED DRYER RECEPTACLE DISCONNECT SWITCH FUSED DISCONNECT MOTOR STARTER COMBINATION MOTOR STARTER, DISCONNECT MOTOR CONNECTION EQUIPMENT CONNECTION CONTACTOR MOTOR RATED SWITCH PANEL — 208/120 OR 240/120 VOLT SYSTEM, +6' TO TOP U.N.O. ZS- -tZ— TRANSFER SWITCH CIRCUIT BREAKER RISER SYMBOLS • DRAW OUT CIRCUIT BREAKER FEEDER DESIGNATION FUSED SWITCH y GROUND PANEL PANEL TRANSFORMER CABLE TO BUS CONNECTION AVAILABLE SHORT CIRCUIT CURRENT METER SYMBOLS & ABBREVIATIONS XX NL 0 a NL azo $os to os LIGHTING SYMBOLS FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "NL" INDICATES 24HR NIGHTLIGHT OPERATION FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FULL— SHADED FIXTURES SHALL HAVE INTEGRAL BATTERY BALLASTS SERVICE PANEL, "NL" INDICATES 24HR NIGHTLIGHT OPERATION POLE MOUNTED EXTERIOR LIGHT FIXTURE BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN — ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. BATTERY POWERED EXIT SIGN WITH INTEGRAL EMERGENCY LIGHTS, ARROWS AS INDICATED (TYPE X1) SINGLE POLE SWITCH (LETTER INDICATES SWITCH LEG) OCCUPANCY SENSOR WALL SWITCH 3 WAY SWITCH INCANDESCENT DIMMER /SWITCH FLUORESCENT DIMMER /SWITCH DAYLIGHT SENSOR, # INDICATES CONTROLLED CIRCUIT DESIGNATION CEILING OCCUPANCY SENSOR ac PHOTO —CELL SWITCH MOUNTED UNDER SOFFIT, ORIENT NORTH TIMECLOCK m • FIXTURE PENDANT MOUNTED o WALL SCONCE SURFACE MOUNT 2X4 TRACK LIGHTING O 1 1 'O' A A SIGNAL & COMMUNICATION SYMBOLS MAGNETIC DOOR HOLD —OPEN. INTERNAL TO CLOSER HARDWARE WHERE SHOWN AT HINGE. FIRE ALARM MANUAL STATION +48" • SMOKE DETECTOR "D" SUBSCRIPT INDICATES DUCT DETECTOR "H" SUBSCRIPT INDICATES HEAT DETECTOR "R" SUBSCRIPT INDICATES 120V RESIDENCE DEVICE WITH AUDIBLE TONE ALARM, BATTERY BACK —UP lc COMBINATION HORN /STROBE, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE ND COMBINATION HORN /STROBE, CEILING MOUNTED 7I3 FIRE ALARM STROBE ONLY, WALL MOUNTED AT +80" UNLESS NOTED OTHERWISE >0 FIRE ALARM STROBE ONLY, CEILING MOUNTED FIRE ALARM CONTROL PANEL w ► TELEPHONE OUTLET: "W" INDICATES WALL PHONE AT +54" D DATA OUTLET D COMBINATION TELE /DATA OUTLET Q COMBINATION FIRE /SMOKE DAMPER CONNECTION MOTORIZED DAMPER 120V E ■MC MAGNETIC CONTACTS FOR WINDOW OR DOOR MONITORING TV OUTLET 0 CEILING MOUNTED SPEAKER • WALL MOUNTED SPEAKER • MICROPHONE CARD READER AUDIBLE DOOR ALARM D+ VOLUME CONTROL AT +54" INTERCOM STATION ELECTRIC STRIKE El CIII 11 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE.: Rsvisions will require a new plan submittal end may include additional plan review fees._ 1 • /1/ XXX MISCELLANEOUS FLAG NOTE REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE REMOVE EXISTING ELECTRICAL EQUIPMENT EQUIPMENT IDENTIFIER TYPICAL ROOM DETAIL REFERENCES: XX — INDICATES DETAIL NUMBER M — INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION EY.Y — INDICATES SHEET WHERE DETAIL IS FOUND DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL PROPERTY LINE --4 —x --•- FENCING CABLE TRAY Q INDICATES COMBINATION POWER /TELE /DATA POKE — THRU FLUSH O FURNITURE FEED JUNTION BOX. ABBREVIATIONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE AWG AMERICAN WIRE GAGE CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED DW DISHWASHER (E) EXISTING EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR G, GND GROUND GD GARBAGE DISPOSAL GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER TANK IGN IGNITION IH INSTA HOT J —BOX MW N P PNL PROVIDE RO RECPT REF S TELCO TELE TYP UC UNO V W 0 W/0 WP SEPARATE PERMIT REQUIRED FOR tibefethanloal Q Elegy Plumbing Gas Pipes City of Tukwila BUILDING DIVISION JUNCTION BOX MICROWAVE — COORDINATE MOUNTING HEIGHT NEUTRAL POLE PANEL FURNISH AND INSTALL RACEWAY ONLY RECEPTACLE REFRIGERATOR SAFETY TYPE TELEPHONE COMPANY TELEPHONE TYPICAL UNDERCABINET UNLESS NOTED OTHERWISE VOLT WIRE OR WATT PHASE. WITHOUT WEATHERPROOF COMPLIANCE FOR NFPA �NCE WITH NEC NW 2�4�2010 r� kv City of BUILDING kwila (VISION Kit COPY Pennft pir,r review wren' is subject to ens and en j . of construction dominions does not authorize ti c: V,olaton of an - -dopted code or ordnance. Receit dammed P eld (..:L4 and conditions is adolowledged: City Of Tilkwila BUILDING DMSIt ELlO - o1s RECEIVED NOV 15 2010 PERMIT CENTER BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6448 Seattle, Washington 98121 fax: (206)223 -8485 N A O 2 0 Architecture 0 co ofco c n O C N ▪ g cn cu t N a°o M co or- N N m • Em- z o o_ cva 1 EXPIRES 1 -17 -12 I 0 —J co M co CO Eg• Q Z Q� O I- V cF) F-- 17-:; r 0 v; CD co !i/. LIL U DRAWING ISSUE BID SET: JULY 12, 2010 DRAWING TITLE SYMBOLS AND ABBREVIATIONS SCALE: PLOT DATE: CAD FILE: PROJ. MGR. :. DRAFTER: NONE JULY 12, 2010 E00.0.DWG ER JG SHEET NO. E00.0 rided to Builders Exchange of WA, Inc, For usage Conditions Agreement see www,bxwa,com - Always Verify Scale d io 6 GENERAL NOTES: 1„ COORDINATE SEATTLE CITY UGHT SERVICE AND INSTALLATION REQUIREMENTS WITH SCL REPRESENTATIVE TOSH SHARP (206)388 -1551 2. COORDINATE TELECOM SERVICE AND INSTALLATION REQUIREMENTS WITH QWEST REPRESENTATIVE MIKE FUQUA (253)297 -3785. SERVICE REQUIREMENTS ARE ANTICIPATED TO BE 6 -8 LINES WITH PHONE/INTERNET SERVICE. VERIFY NUMBER OF LINES 1MTH OWNER PRIOR TO SUBMITTING SERVICE APPLICATION. 1 CONTRACTOR TO PROVIDE COMPLETE INTERCOM SYSTEM IAITH DUAL MASTER STATIONS AND REMOTE CALL STATION VATH ASSOCIATED PARTS AND WIRING TO MAKE FOR A FULLY FUNCTIONAL SYSTEM. SYSTEM SHOWN ON THIS SHEET IS FOR REFERENCE ONLY TO SHOW THE INTENT OF THE SYSTEM. 1 0 L, 0 FLAG NOTES; ▪ RELOCATE EXISTING GATE MOTOR AND ASSOCIATED LOOP DETECTORS. INSTALL HANDHOLE AND EXTEND CIRCUIT, COORDINATE NEW GATE AND LOOP DETECTOR LOCATIONS WITH CIVIL. SEE DWG SV -1 AND CUTSHEET ON THIS DRAWING FOR MORE INFORMATION. El> RELOCATE EXISTING GATE KEYPAD. TO BE FED FROM RELOCATED GATE CONTROLLER. SEE DWG SV -1 FOR MORE INFORMATION. PROVIDE CONDUIT PATHWAY ONLY FROM SCL VAULT TO NEW METER. SCL WiLL INSTALL AND TERMINATE CONDUCTORS. PROVIDE CONDUIT PATHWAY FROM POLE TO BUILDING AS SHOWN. CONDUIT INSTALLATION SHALL MEET QWEST REQUIREMENTS. COORDINATE LOCATION OF SERVICE AT THE BUILDING WITH THE ARCHITECT. TO SCL VAULT APPROX. 85FT NORTH FROM THIS POINT 2 "C PVC -+ SCH40 / B1 1 11 C 4 4 4 :I •4 4 4., 24 .4 4 ' 1r 4 4' '24 • • 1 . 3/4"C PVC' Sc H40 ?1- 2',3112nt' (VIA PHOTOCELL '11 CONTROL) • (rip) 4. 4 . •.4 • 4 • 4 • 4' 4• '4 • 41,1 TELEPHONE UTILITY DEMARCI (BUILDING EXTERIOR) --••-••• X -mow.. xw 1 4 "C PVC ��� /1 / I SCH40 ___ .1 DATE KEYPAD .7t..70/___ ._ CIIEW L0CA11ON) ,,/ 1 I x / 2 ,t PANEL P1 -m- PHOTOCELL MOUNT ON ROOF E C E Li 4 • - 4 4• • 4a ' VEHICLE GATE MOTOR (NEW LOCATION) ® 3/4 "C PVC SCH40 •3� Pic' SCH40 EXISTING UTILITY POLE /1375068 PACIFIC COURT COMMUNITY BUILDING ENLARGED SITE PLAN 118" =1' -0" Et> INTERCOM SYSTEM: PROVIDE TWO INTERCOM MASTER STATIONS WITH GATE RELEASE BUTTONS AT OFFICE AND MANAGER'S UNIT. SEE DETAIL 11 THIS SHEET FOR SYSTEM WIRING REQUIREMENTS AND COMPONENTS. ELECTRIC STRIKE PROVIDED WITH GATE HARDWARE. COORDINATE WITH SYSTEM SUPPLIER FOR APPROPRIATE PARTS. PROVIDE BREAKOUT ALLOWANCE FOR COST ASSOCIATED WITH ROUGHING IN STATION AT MANAGERS APARTMENT. SEE DETAILI3 THIS SHEET FOR BOLLARD MOUNTING REQUIREMENTS. SEE LIGHT FIXTURE SCHEDULE ON E30.0 FOR BOLLARD INFORMATION. PROVIDE VANDAL RESISTANT SPEAKER AND MOUNT AT ADA REQUIRED HEIGHT. DUCTBANK SHALL BE PER SCL CONSTRUCTION GUIDELINE U2- 10/NDK -50. PROVIDE CONDUIT PATHWAY FOR REQUIRED KEYPAD WIRING. PROVIDE CONDUIT PATHWAY FOR REQUIRED GATE RELEASE CONTROL/INTERCOM INTERFACE. TO MANAGERS UNIT. COORDINATE FINAL LOCATION VWTH OWNER. PROVIDE RIGID RACEWAY UP TO POINT OF ENTRY TO APARTMENT. x x 3/4 "C PVC x SCH40 P1 -24 POWER FOR BUILDING SIGNAGE (VIA PHOTOCELL/TC) BUILDING SIGN 4 1 1 AIPHONE LEM -1 DLC Multi- Master Access Sentry System Master Station for Multiple Master Use, Including Occupied Lamp Floes* reed snd understand all Instructions before installation. Door f�I LE -D 1\ -E - INSTRUCTIONS - Master tY'1 LEM -1 DLC 1 , EL -12S E EL Master #2 LEM -1DLC 1, PT ON 0 PT 12 ON L@i IMPORTANT!!! Each master REQUIRES an individual PT -1210N power supply. E R EL ELJ OPERATION NOTES: 1. Only one master can be used at a time. 2. When the answering master presses the TALK button, the red LED above the OFF switch will light on both masters. This feature Is controlled by the "R" wire between masters. 3. When the OCCUPIED light le Illuminated, do not press the TALK button on the non - answering master, or a feedback will be heard throughout the system. If this occurs, turn oft one of the masters (depress OFF button). At that time, communication between the door and the answering master can continua normally. 4. There is no communication between masters. INSTALLATION GUIDELINES: 1. Separate power supplies (12 -16V AC or 12 -24V DC) are required at each master station. DO NOT CONNECT +1- WIRES BETWEEN MASTERS. Keep wires for power and communication in separate jackets. 2. The door strike can be powered from one of these power sources (es shown) or from an independent source. Door release confect rating on the LEM -1 DLC is 24V DC, 1A max. 3. The EL -12S Is designed for a standard woad framed door, and for light to medium usage. If a different type of door is used, install a strike appropriate for that door. 4. The LEM -IDLC provides a "normally open" contact closure for door release, 6. H using a magnetic lock, either the RY -16L or RY -24L relay will be required to get a normally closed contact. (See diagram on back) Alphone Communication Systems 1700 1301h Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071 Toll Free Technical Support: 1. 800- 892.0200 E -mail tech@alphone.com DETAIL #1 - PEDESTRIAN GATE INTERCOM SYSTEM VEHICULAR LOOP DETECTOR INSTALLATION Guidelines for Vehicular Loop Detector Installation L. Prevent sharp colliers in the geomety of the Inop sensor. 2. install the appropriate number of turns for your loop geometry based on the loop perimeter. Use 'fable C (below) as a guide. 3, Use XLP (cross - linked - polyethylene) type of wire. This wire reduces the effects of moisture and other environmental events in altering the functionality of the vehicular loop detector. 4. Twist the lend wire at least 6 turns per foot. 5, Use BACKER -ROD to minimize damage to the loop detector wire prior to using the sealant. G Place the loop detector wire and adjust the sensitivity of the vehicular loop detector unit in a way to minimize the effects 01' the gate over the loop detector wire. IMPORTANT - Some of the following parameters may affect the proper hinctionality of the vehicular loop detector (consult the installation manual and the manufacturer of the vehicular loop detector). • (late size, • Number of turns in the loop sensor wire: • Distance limn the loop sensor wire to the gate either at the open or close position. sew Cut-.I 1*-- Sealant Sacker -Rod Vehicular Loop Detector Wire (3 Turns Shown) Table C - Recommended Number of Turns Perimeter in Feet Number of Turns 10 5 20 4 30 -40 3 50 -100 2 cif Th VIKING -I Continuously Wind Wiro In Loop Blot for the Required Number of Loops (2 Loops Shown) Provide Additional Saw Cuts to Eliminate Sharp Comers 1/8" to 1/4" sew Blot. Twist We Outslds the Loop 6 TW lsts/Foot Until Its Connection to Iho.Loop Dotootor ACCESS SYSTEMS' TECHNICAL SUPPORT 1 800 HOB 0884 21 DETAIL #2 - LOOP DETECTOR INSTALLATION REVIEWED .EO COMPLIANCE WITH NFPA70 -NEC NOV 242010 City of Tukwila BUILDING DIVISION External Signaling: Trigger and external ball or sounder when the door station button is pressed. LE Series Sub n LEM -1 DUC To door ales �- PPP pow EL EL E LEM -1 DUC n PT-1210N 0 + 0, R EL EL E 12V C Powe NOTE: Supply WHITE RED RY -AC LLCW YELLOW BELL TO EXTERNAL POWER 1. Use a 12V DC power source, 500mA or greater, for the RY -AC. An Aiphone PS- 1225UL can be used to power both the relay and the one LEM -IDUC. The second LEM -IDUC must be powered separately. 2. The LEM -1DUC that does not have the RY -AC connected may use the PT -1210N power supply. SYSTEM CONFIGURATION: LEM -1 DL/C with Door Release contact activating a Normally Closed relay for Magnetic Lock Note: For applications requiring a Normally Closed (N/C) contact (Magnetic locks, etc), an external relay should be chosen based on the lock's power source. • When using a 12.18V DC magnetic lock; Alphone's RY-18L may be used • For 24V DC magnetic locks, Aiphone's RY-24L relay may be used. • A 3'" party relay of similar specifications may also be used. Refer to manufacture's documentation for connection details. LE Series Sub Leave jumper between E and - attaohed Magnotic Lock LEM-1DL/C COM N/C Val RV -t BL / RV -24L Bmm 0rc Use Brown 8 Yellowwlres when connecting to Meglock. Red Blk PT-1210N EL MAGNETIC LOCK WIRING METHOD: (Normally Closed contact) Lock Power. Power source for Magnetic Lock When using 12 -18V DC, use the RY -18L. When using 24.36V DC, use the RY -24L. LEM•1DLC Instr, 011OJD minas of :ON taw BOLLARD TUBE -- 06.6±", RPP. S 16 -18UNC FLAT HEAD SCREW rr, 3xAt 120 SUITARI F CONDUIT (SIRE9IY. BY OTHERS OTHERS CONCRETE FOUNDATION BY OTHERS r 'LUSH MOUNTING FLUSH MOUNTING DOES NOT RFQUIRF I FVF ING NUTS AND WASHERS, IJSF BASF PI ATF WITH FLAT SIDE DOWN 0#04# is% Z://_A BOLLARD FOO PR NIUBE 6.63'3', REF. SOLIARD BASE FOOTPRINT SAD"¢, REF.. 1t; WHD C 9 1041 8/22/08 WHD 0 1 09.012 ALD 2/26!38 WI ID ASPR L 09 -065 REV 00 DOC ALL) BY 5/4/09 DATE LEVELING NW MOWING MOUN'TIN'G WITH LEVELING NUTS • CAST RASE MUST BASE WASHERS MUTT AND W ASSEMBLY WASHERS MUST RE GHT `AGAINST 90311 SIDES SASE IATE WITH FLATUbE DETAIL SIDE FACINGIIP. (SCALE 1 :4) - 131 1/2 STFFI ANCHOR PBOLT5, EACH WITH [2 HEAVY RATE WASHERS AND 2 I /2.13UNC HEX NUTS ISIiPPDEDI SOLI CIRCLE 4..51:" DIA. REF. PATH OR ■ I; ( (FRWARD) VERIFY BOLD LINE , ''• Is 6" LONG TEMPLATE FOR: CLV8,CF73,RCHD1, RDHDI,RFHD1,AB10, AB08,LL -305 LL -303, LL -304 NOT TO SCALE CONSULT FACTORY FOR FULL SIZE TEMPLATE. k' ' \,•CLEARANC= HOLE FOR yLl I /2 -19UNC 56ANCHREOR 5OLT • yt .0 20 .0.'0 F, CON-)113 STAR AREA PHILIPS 100 Ca.lwcy. PO Box 128 Ulllestawa. .A 173400125 Mon]. 717359 7,31 Faso 7173:5 5515 wvw.hcc .*co -, CONFIDENTIAL WW1 ormUno onn140 t146 401741M0, HADCO o Fr ilos sso l;7no 'HAIn 31004 uy nul W tqw2spwu .41.1.10u:wpm> .1 Nal 6000,10?E14200 Nrysnelrxuv 01 l0 Fvl the k1 oo 01 an a Data. heroes shot be IO the 0k h0 nor- 111Mx34 i3544ADC0,nf itpl F0Wbrand TLE: 704PLATE roe cr1La TECNIRA a COST LOUVER VANDAL BOLLARD (CAST BASE PLATE 015001521 DWG NO: Te1800122 J 512L1 5 ALB! 0145M SESPEC RE:k 'AIL MYEN■01e ME N & CHFS. 'ALLTH EARS ARE VAC RE OR 21P.211 AFFR 0251145 'ALL naEADS AREro 3E vERe'a) N101 A 114 rJl GAFF DRAVN or M. 1. RENNER 0A-F 61319/ r.LrSlxrow B, DORON DATE: WON n5PR SY E HADDAD 3071 6/3/97 MATERIAL MAKE PROM I 1 "X I!' WI1111 LIONL, PAPER E ^04 -01 -11 Rov.06 I SCALE; NISI %EV 10F I - nr) hOT SCAIr 1113 flR4WIN(1' DETAIL #3 - BOLLARD INSTALLATION ELO QjZ5 RECEIVED NOV 15 2010 PERMIT CENTER BrN Engineering, Inc. Consulting &Waft 2101 Ylh Avenue Bulb 218 tek 0148 HMIs, Washi ion i0121 88 - LLI o a:z < pia EXPIRES 1 -17 -12 DRAWING ISSUE BID SET: JULY 12, 2010 DRAWING TITLE ELECTRICAL SITE PLAN SCALE: AS NOTED PLOT DATE: JUN 7 2010 CAD FILE: E10.0.DWG PROJ. MGR.: ER DRAFTER JG SHEET NO. E10.0 ryvidad to RIIiIr1Ar4 Pvnha :na of WA Inn For [Sarno Cnnrlitinna AnraamAnt SERE \MIAs/ hvwa cnm . Alwava Varifv Scale 4 N 0 MECHANICAL EQUIPMENT CONNECTION SCHEDULE PANEL SCHEDULE PANEL: p1 LOCATION: PACIFIC COURT COMMUNITY SE LABEL BLDG ' VOLTS: AIC RATING: NEUTRAL: 240 Y/ 10;000 100% 120 P 1 W :'3 MOUNT: SURFACE X FLUSH ' ❑ FED FROM UTILITY AMP: MLO MCB X 200 ❑ TYPE: EXI STING NEW X _ _ _ ,BMA: ❑ CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR M P H CIR V P CKT SKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION OTY HP FLA I LTG INTERIOR SPACES REC_ FETING ROOM CE_, ,MEE..G..,,_ ., RCC LARGEOFFICC REC- LARGE OFFICE COMPUTER RECPTS REC - OFFICEICOMP RMrRESTROOMS 1 REC RESTROOMS UM & FAN COIL , __ , _ __,....,....__.. WATER HEATER ._•. �_.,,._. _.:.•..._ - COVE HEATERS - COMMUNJTV ROOM ____ SPARE SPARE LTG REC REC REC REC REC REC _ MISC _... MISC MISC MISC MISC MISC -"-'<* 1_50 1 08 126 1.20 072 1.08 0T35 0.50 1 1.25 ,. 1.40 140 20 20 20 20 20 20 20 20 20 _ 20 20 20__.. 20 1 1 1 1 1 1 1 2 ,._ 2 __.._ 1 1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 A 8 A B A B • A B 8 A B A .2_.__....__2 4 6 8 10 12 14 .- ..1�.._ 20 _.._ 22 .___24 ..__,26 28 30 1 1 1 1 , 1 - _ 2• - 2 - 1 1 1 1 50m 20 20 :... 20 20 __ 20_ __:1. 15 - 15 ._._ 20 20 20 400_ 400 025 _._._ 120 1 64 1.00 08.___ 127 1.27 0 52 052 050 _- --- KITCH IQTCH KITCH KITCH RES RES MISC MISC MISC MISC MISC_._ - -_LTG .,.._BUILDING OVEN/RANGE RANGE HOOD _ .____... ....... ............. ......._...._....- ....... -._... DISI WASIICR SMALL APPLIANCE SMALL APPLIANCE COMPUTER ROOM ___...__.._ _ COVEHEATER OFFICE COMPUTER WOMENS _ ............. - COVE HEATERS - MEWS; HALL, MEETING ; ..,,_. __..___._. .............._.. SIGNAGE___ -- .............:-....-__- ___.._......- ..............,._ SPARE SPARE SPARE ESTIMATED MAXIMUM DEMAND'(EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE; CONNECTED LIGHTING LTG 2.00 KVA RESIDENT LTC/RECPT RES 0.00 KVA SMALL A MOTOR -64 KVA 0 50 KVA REMAINING MOTORS RES 2 ORS MTR -0.50 KVA GEN PURPOSE RECPT REC 576 KVA COMPUTER RECPT' MISC 1.08 ; KVA EQUIP/OTHER MISC 0.00 KVA HEATING MISC 928 KVA ELEVATOR ELEV 0.00 ; KVA KITCHEN EQPT KITCH 9.45: KVA -------- TOTALS, 3021 KVA 128.38 AMPS LOAD TYPE NOTES: E.M.D. CALCULATED 2.50 KVA (125%) 0.00 KVA 900135!25 ( 0.2.64 KVA (100135125 63 KVA (125 -0.50 KVA (100°10) 5.78 KVA { 50% ! 1 -08 KVA (100 0.00 KVA (100 9.88 KVA (100 0.00 KVA § 8.51 KVA 1 - 30.49 KVA 127:04 AMPS LOAD TAKEN AT INDICATED CIRCUITAT 100% °lu 96) %) a 10KVA) %) %) %) 100 % 90% _ DEMAND %) CONNECTED PHASE LOADING PHASEA:' 15.75 KVA PHASE 8: 15.06 KVA A GENERAL NOTES: 1 SERVICE RATED FLAG NOTES: 1 "COMB" _'COMBINATION LOAD TYPES ON INDICATED CIRCUIT RES' - RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE "MISC" = I EQUIP, COMPUTER REC OR I-1TG LOAD ON INDICATED MECHANICAL EQUIPMENT CONNECTION SCHEDULE ELECTRICAL DATA INDIVIDUAL E GU IPME NT INFORMATION I PACKAGE UNIT INFORMATION'; TOTAL TOTAL ELECT NOSES MARK AR EASE. RVEO LOCATION VOLT: PH 1 I CITY FLA HP FLA I I I 1 VA OTY HP FLA I TYPE OTY HP FLA I OTY KW FLA KVA HEAT PUMP HP -1 LARGE OFFICE 240 1 7 0.7 2. 92 O:fO EXHAUST FAN SCHEDULE EF -I RESTROOIAS CEILING 120 1 t 0.024 0.20 EF -2 RANGE HOOD KITCHEN 120 1 1 0.144 120 0.14 EF.3 1.0 MEETING BOON CEILING 120 1 1 0.024 0.20 0,02 ELECTRIC HEATER SCHEDULE EH -1 ' LO .1TO RMA, hIENS ROOM 240 1 2 0.42 3,80 044 4 EI4.2 COMIAUNITVSPACE 240 1 2.. 1.4. 1167 2.SO, 4 EH -3 Shi MEETINO ROOM 240 1 2 0.7 5.83 1,40 4 E11.4 COMPUTER ROOM 240 1 1 0.94 3.02 '. 0.04 : 4 EH -5 HALL,WOMENSM ROOM 240 1 2' 0.21 - 175 D.42 4 DOMESTIC WATER 'HEA1ER- SCHEDULE WH.i cOIAIAUNITYROOM 240 1 1 0.42 1,75 0,42 FAN COIL SCHEDULE FC -1 COIAIAUNITYROOM 240 1 ,I 1: 0.12 0.60 012 NOTES' 1 FOR 120V FANS PROVIDE MOTOR RATED SW TCH FOR LOCAL DISCONHECTWHERE REQUIRED 3 FI1 RY 2 MANUAI STARTFRWtAUTOMATIC MOTOR STARTER WITH HOA . COIL VOLTAGE 120V F e f)VFRI ()An FRTF(111014 RHAI I C/ RF PROVIfFr1 ANI IPIRTA1l 4 LINE VOLTAGE (120V)TSTATSHALL BE PROVIDED BY M.C. AND INSTALLED BY E.C. 5 FAN SPEED CONTROL PROVIDED BY M.C., INSTALLED BY E.C. ON FAN HOUSING 5 FAN SPEED CONTROL PROVIDED BY M.C., INSTALLED BY E.C, 7 UNIT IS PROVIDED AND INSTALLED BY E,C.- F07EIectric Cabinet Haters 8 Not Used 9 VFD' PROVIDED BY MC, INSTALLED BY EC ALL CONNECTIONS BY EC 10, Not Used 11 SMOKE DETECTOR PROVIDED BY M.C, INSTALLED BY B.C. FLAG NOTES: UTILITY METER /CT PER SCL REQUIREMENTS. GROUND PER NEC 250. ROUTE CONDUIT MINIMUM 18" BELOW GRADE OR BACK ENTRY INTO PANEL.. 2 "PVC, 3 #3/0 CU 75 -DEG RATED GRADE LEVEL PANEL P1 200A MCB 200A (SE LABEL) 240/120V, 1PH 3W e.- #4G MAIN FLOOR TO SCL 2- --J18" MI 2 "PVC, 313/0 CU 75 -DEG RATED J L___J m ONE= LINE RISER DIAGRAM UNDERGROUND SERVICE LOCATED BELOW NT COU R E 30AS 20AF 2:5KW CCTV 10 10 WP 3 X CCTV 1 -19,21 P1 -12 P1 -8 KITCHEN DISHWASHER F1 NgEHOOD +72" OVEN 240V/1P/50A P1 -2,4 3/4 "C -3 #8, 1#10C 10 REFR GERATOR 'P1 -10 PANEL P1 P1 -3 P1 -23,25 COMMUNI Y SPACE 620 F HP -1 0.7KW H 30AS 1 5 AF P1 -15,17 FC -1 0.12KW 9 OFFICE 220 SF 3 + 72" EH -2 1.4KW EH -3 0.7KW 11 1.21:2.1 0.21KW P1 -1,T1 / O' FICE 7' SF 011 COMPUTE 75 SF WOMEN 16,18 11 0.7KW EH -4 0.94KW EF -3 0.6KW STORAGE 5 HALL v EH -1 0.42KW 5 D 5 WP 1.2±.1.1 0.21KW F-� EH -1 0.42KW CCTV REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC NOV 2 4 2010 City of Tukwila ,BUILDING DIVISION PACIFIC COURT COMMUNITY BUILDING FLOOR PLAN - POWER AND COMM. 1/4" =11 -0" FLAG NOTES: SEE DRAWING E10 FOR UTILITY REQUIREMENTS. EXHAUST FANS CONTROLLED BY LIGHT SWITCH. SEE DRAWING E30 FOR ADDITIONAL INFORMATION. PROVIDE J -BOX AND PATHWAY FOR SECURITY CAMERA. SEE SECURITY SYSTEM REQUIREMENTS THIS SHEET FOR ADDITIONAL INFORMATION. COORDINATE WITH MECHANICAL AND CASEWORK DETAILS. PROVIDE ADA REMOTE SWITCHES FOR LIGHTS AND FAN OPERATIONS. HOT WATER CIRC PUMP WILL BE FURNISHED WITH A CORD AND PLUG. LOCATE RECEPTACLE UNDER COUNTER. COORDINATE LOCATION WITH MECHANICAL PRIOR TO ROUGH -IN. EXHAUST FAN OPERATES VIA CO2 DETECTION PROVIDED BY MECHANICAL. COORDINATE INTERFACE REQUIREMENTS PRIOR TO ROUGH -IN. COVE HEATERS FURNISHED WITH INTERNAL DISCONNECT. MECHANICAL TO PROVIDE LINE VOLTAGE T -STAT. CONNECTED BY ELECTRICAL CONTRACTOR. TV SERVICE WILL BE PROVIDED BY DIRECT TV AS PART OF THE QWEST SERVICE PACKAGE. COORDINATE REQUIREMENTS AND TV LOCATION WITH OWNER AND QWEST. SEE DRAWING E10 FOR QWEST CONTACT INFORMATION. PROVIDE FIRE ALARM SYSTEM WITH FULL DETECTION, ANNUNCIATION. PULL STATIONS AND MONITORING PER CITY OF TUKWILA REQUIREMENTS. REQUIRED DEVICES ARE NOT INDICATED ON DRAWINGS, BUT SHALL BE INDICATED ON APPROVED FIRE ALARM SHOP DRAWINGS. SEE SPECIFICATIONS' FOR FIRE ALARM VENDOR REQUIREMENTS. INTERCOM MASTER STATION #1. SEE DRAWING E10.0 FOR ADDITIONAL INFORMATION. SECURITY SYSTEM REQUIREMENTS: 1. PER DIRECTION OF KING COUNTY HOUSING AUTHORITY REPRESENTATIVE, THE SECURITY SYSTEM WILL BE PROVIDED AND INSTALLED BY CREATIVE SURVEILLANCE SOLUTIONS AND CARRIED AS PART OF THE ELECTRICAL CONTRACTORS SCOPE. SYSTEM CONSISTS OF THE FOLLOWING: 1. 1 - LPC MATRIX 1308 DVR 2. 3 - CD55NV36S PTZ CAMERAS 3. 1 - RS485 CONVERTER 4. 1 - APC1500 UPS 5. 1 HP 17" FLAT PANEL DISPLAY 6. 500FT - SIAMESE CABLE WITH 18 /4AWG 7. 1 - MISC CONNECTORS AND OTHER ITEMS AS NEEDED CONTACT INFORMATION IS: CSS INC ROBERT CASPERSON 18650 142ND AVE NE WOODINVILLE, WA 98072 (425) 487 - 1393. ELlOO9's RECEIVED NOV 15 2010 PERMIT CENTER BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 216 teL (208)223.6448 Seattle, Washington 98121 fax: (206)223.6485 etS Architecture EXPIRES 1 -17 -12 DRAWING ISSUE BID SET: JULY 12, 2010 DRAWING TITLE POWER AND COMM PLAN SCALE: PLOT DATE: CAD FILE: PROJ. MGR.: DRAFTER: 1/4" = 1' -0" JULY 12, 2010 E20.0.DWG ER JG SHEET NO. E20.0 .....:.A•..1 i� d..:lde..ti. G:....M......•...41AIA I... Go". .,....ww P`w..•4114....... A • 146.44• nnw. _ Dluum a V. IFt• C•sln 7/13/2010 11 22 LIGHT FIXTURE SCHEDULE Project Address 'pacific Court Apartments ! Date 7/1312010 4026 S 146th Street For Building Department Use LAMP' Applicant Adore I BrN Engineering, Inc 1.0 2101 Ave Sutra 215 - Seattle, WA Applicant Address:' 88121 ApplicantFhona:, ; (208) 223- 6448 TYPE MANUFACTURER SERIES Na (CATALOG NO.) VOLT NO TYPE BALLAST FIXTURE WATTS DESCRIPTION FLAG NOTES spaces clearly on plans.) scnptive igChecklist htingPoovrAIIowanceLI SysterrsAnalysis tXnL (S Indicate Prescriptive a LPA 1800.0 360.0 Alteration Exceptions No than es are been made to the li M ❑ changes i. g lighting (ah•ah apprepriete has• ee.. n3z,a) F1 UGHTOUER BASELYTE -BSLI 411 Direcl/lndheel 120 2 F32T8 Electronic (1010110 60 Pendant mount Weer fluorescent IlxutlNt 11e okcrolt cable. 11r0 four Toot fixtures mount together to lam on 811 section. 1457:0 F2 LIGHTOUER EYE-01. Sales eft Direct 120 2 r32ye Electronic <101iTHO eo Surface mount linear fluorescent Mute with duel bolloal for independent operation of each bulb 12 F3 LIGHTOUER EYE -OL Wes 411 Direct 120 2 F32T8 Electronic <lO%THD 60 Surface mount linear fluorescent fixture with single boaoel 1 F4 LIGHTOUER BELMONT 6" Cloud - 24" Length 120 2 FI7T8 Electronic (101iTH0 42 Surface mount fluorescent - Vanity 1 F5 LNittTO1.BR 4' -0" Fluor $trip 1L -F32T8 120 1 F32T8 Electronic <1ONTH0 30 Surface mounted fluorescent strip fixture, 48" nominal length, low profile steal housing Fe LIGHTOUER LUMIRONOE 11" Sutton Drum Fixture 120 2 13W QUAD Electron: 41010111) 28 Contemporary Surface Drum Fixture, *wok diffuser, Matte si er trim 81 HADCO Vandal Resistant Bollard CLVB 120 1 CFL32 Electronic CIOST140 32 Coordinate roof style with architect L1 MADE -LITE AWS4 SERIES 120 1 CFL26 El ctroni 26 Rounded wedge wall Sconce. Die Cost Aluminum Housing. optional emergency battery pock GENERAL-NOTES 1. AU. INDICATED CATALOG NUMBERS REPRESENT A DESIGN BASS ONLY AND CORRESPOND TO THE USTED MANUFACTURERS SERIES !UMBER; ALL OPTIONS. ACCESSORIES AND/OR FIXTURE COMPONENTS MAY NOT BE REFLECTED IN THIS NUMBER AND CONTRACTOR RESPONSIBLE FOR PROVIDING ALL SUCH ITEMS DISCLOSED IN FIXTURE DESCRIPTION AND /OR" SPECIFICATIONS. SUBSTITUTION OF FIXTURE TYPES MILL ONLY BE ACCEPTED IF PHOTOMETRIC% CCNSTRUCTION/COMPONENT QUALITY AND DESIGN INTEGRITY ARE SHOWN TO BE EQUAL TO THE DESIGN INTENT. FINAL DISCRETION TO BE DETERMINED BY ENGINEER. ALL SUBSTITUTIONS SHALL INCLUDE PHOTDMETRICS' AND BE RECEIVED (5) BUSINESS DAYS PRIOR TO CLOSING FOR ENGNEERNG ANALYSIS 2 CONTRACTOR TO VERIFY CEIUNG CONDITIONS FOR PROPER MOUNTING HARDWARE FLAG NOTE Lighting Summary 2006 Xashingten etata ente.Menllal Ellerpl a e :C amplIanosFbrme. LTG -INT Revised" ,duly 2007. Project Info Project Address 'pacific Court Apartments ! Date 7/1312010 4026 S 146th Street For Building Department Use 'Cawlla, WA 98186 Applicant Adore I BrN Engineering, Inc 1.0 2101 Ave Sutra 215 - Seattle, WA Applicant Address:' 88121 ApplicantFhona:, ; (208) 223- 6448 1800.0 360.0 PCOjeCt Desch tion p X X New Buldin �--iAddition ❑Meration, x Mans Included Q I� Refer to WSEC Section 1513for controls and commissioning requirements. New Budding Addition ❑Alteration to WSEC Section 1613 P r controls and commissioning Compliance Option requirements. spaces clearly on plans.) scnptive igChecklist htingPoovrAIIowanceLI SysterrsAnalysis tXnL (S Indicate Prescriptive a LPA 1800.0 360.0 Alteration Exceptions No than es are been made to the li M ❑ changes i. g lighting (ah•ah apprepriete has• ee.. n3z,a) ❑ w, installed lighting wattage is not Less than 60% of factures ne increased, and space use is not changed Building Grounds (luminaries > 100 Watts) A11L.2 �y"r. A1ln &, 4 T its1�47 ..,.- .ter- --. - - --- Location (fborlroom no.) -- -`o- -O --- -o -' -- f Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area LE EL 1 OFFICE 1.0 1467.0 1457.0 1800.0 360.0 Project Description X Q Flans Included New Budding Addition ❑Alteration to WSEC Section 1613 P r controls and commissioning Refer requirements. Proposed Watts may not exceed Allow ed Watts for Category Total Proposed Watts l Compliance Option Com i P P 1800.0 360.0 X Lighting Pow erAllow once Systems Analysis ❑ Building Grounds (luminaries > 100 Watts) Sensor Pj Efficacy > 80 Iumens/W ❑Controlled by motion (list): " from Table 15 -1 (over) - document WI exceptions on form LTG -LFA Totals Proposed Lighting Wattage 1457.0 1457:0 Alteration Exceptions (aheok .pptoprlate bon- t:9o,1132.3) Location (floor /room no.) Fixture ()ascription Number of Fbctures Watts/ Fbdure Watts Proposed F1 Fluores cent Oft 2 -tam p TB 12 80 720.0 F2 1 Ffuores cent Oft 2 -lamp 781 7 80 420.0 F3 Fluores cent 4ft 2 -tam p 78', 1 80 60.0 F4 Fluorescent 2x2 -lamp 78 2 42 84.0 F6 Fluorescent Oft 1 -tamp T8'; 1 30 30.0 r8 i Fluores cent Oft 2 -lamp 79 2 26 52.0 Total Proposed Watts gray not exceed Total lbw ed Watts for hterior Total Proposed WVatts 1366:0 Notes: 1. For proposed Fixture Description, indicate fixture type, lanp type (e.g. T -8); number of lamps in the fixture, and ballast type (1 included). For track lighting, 1st the length of track n feet) h addition to the fixture, lane and ballast nforn tan. 2. For proposed WattslFixtture, use nand acturer's listed nnxirmminput wattage of the fbtture (not simply the lamp w attage) and other criteria as specified In Section 1530. For hard wired balasts only the default table in the NRECTechnical Reference Manual Tray also be used For track lighting, list the greater of actual lurrrlaire w attage or length of track rrutiplied by 50, or as appicable, the wattage of current Ihithg devices or of the transformer. 3 List all fixtures. For exerrpt lighting note section and exception number and leave Watts/Fixture blank. Exterior Lighting Summary ∎o -• ": ash tog tong -.tsl• ones dent slE' nor gp Ced• a :p Hance LTG -EXT Revised July 20071 Project Info AojectAddress Pacific Court Apartments Date 7/13/2010 40288. 146th Street For Building Department Use Tukwila, WA 98168 Allow ed Watts x ft2 (or x If) Applicant Name: BrN Engineering, 9th Ave Suite 216 - Seattle, WA Applicant Address:2101 t d 208 T Applicant Phone: (208) 223 -84 46 1800.0 360.0 Project Description X Q Flans Included New Budding Addition ❑Alteration to WSEC Section 1613 P r controls and commissioning Refer requirements. Proposed Watts may not exceed Allow ed Watts for Category Total Proposed Watts l Compliance Option Com i P P 1800.0 360.0 X Lighting Pow erAllow once Systems Analysis ❑ Building Grounds (luminaries > 100 Watts) Sensor Pj Efficacy > 80 Iumens/W ❑Controlled by motion (list): ❑Exemption 156.0 Alteration Exceptions (aheok .pptoprlate bon- t:9o,1132.3) No changes are being made to the lighting Less than 60% of fixtures new , installed lighting w attage is not increased, and ❑ g use is not changed Tradable Maximum Allowed U .. --, Fixture Description pt Ion Tradable Locations Description ,Allow ed Watts s per ft2 or If Area (ft2), perimeter (If or # of terns Allow ed Watts x ft2 (or x If) Landscape Building Grounds 0.20 1800.0 360.0 Proposed Watts may not exceed Allow ed Watts for Category Total Proposed Watts 128.0 Totals 1800.0 360.0 Tradable Proposed Lighting Wattage Use mfgrlisted maximum input w attage. For fixtures w ith hard -w ired ballasts only, the default table I the NREC Technical Reference Manual may etso be used. Location Fixture Description pt Ion Number of � Fixtu ;Fixtures Watts/ Fixture Watts Proposed Landscape B1 FI Bollard -1 lam p 26W CFL 4 32 128,0 160.0 800.0 Proposed Watts may not exceed Allow ed Watts for Category Total Proposed Watts 128.0 .T.... 'S. -..i �L1.. 11R .. 3........ 1IlVfL- 3 LfL'M.6LL/L\,. £Yli4/4L13LN:LLL LILALJ 1!•LuM s a .�. atbneL • 1 .a.mome.V V Fixture Descrpion Non - Tradable Locations Description Allow ed Watts per ft2 or if Area (ft2), perimeter (If or # of dams Allow ed Watts x ft2 (or x If) Building 1 Facade 5.0 160.0 800.0 Totals 160.0 800.0 Use rnfgr listed maximum input w attage. For fixtures w ith hard- wired ballasts Non- Tradable Proposed Lighting Wattage only, the default table I the NREC Technical Reference Manuel may also be used Location Fixture Descrpion Number of Fixtures Watts/ Fixture Watts Proposed Bldg Facade CFL Wall Sconce 6 26 156.0 Proposed Watts may not exceed Allow ed Watts for Category Total Proposed VVatts 156.0 L1 P1 P1 -9 KIT 00 ©0 PANEL P1 F1 0 X1 F1 b F1 b P1 -1 COI/IMUNITY SPACE 620 SF MNT 7 -'6 "AFF (TYP) F1 0 F1 0 F1 0 F1 0 X1 MNT 7 -'0 "AFF (TYP) F1 OFFICE Q_ 220 SF F1 F1 F1 TYP 1 -9 F2 r TETING ROLIM 140 SF F2 HALL F3 TYP X1 PACIFIC COURT COMMUNITY BUILDING FLOOR PLAN - LIGHTING 1/4" =11 -0" L1 REVIEWED FOR NFPA COMPLIANCE NUV 2 q 2010 City of Tukwila f BUILDING DIVISION GENERAL NOTES: 1, ALL CIRCUITING IS 1/2 0C- 3112AWG UNLESS NOTED OTHERWISE. 2. PROVIDE UNSWITCHED HOT LEG TO ALL EXIT SIGNS AND BATTERY OPERATED EGRESS FIXTURES. 3. WHERE TWO SWITCHES ARE LOCATED IN SAME AREA GANG SWITCHES UNDER ONE COMMON WALLPLATE, FLAG NOTES: PROVIDE DUAL TECHNOLOGY WALL MOUNTED OCCUPANCY SENSOR WITH DUAL RELAY OUTPUTS, WATTSTOPPER MODEL DW -200 -W OR APPROVED EQUAL COORDINATE AUTO /MANUAL SETTINGS WITH OWNER. ?> PROVIDE DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR, WATTSTOPPER MODEL DT -200 WITH POWER PACK OR APPROVED EQUAL. MOUNT AT 10FT AFF, USE SMARTSET FUNCTION FOR AUTOMATIC ADJUSTABILITY. PROVIDE DUAL TECHNOLOGY WALL MOUNTED OCCUPANCY SENSOR, WATTSTOPPER MODEL DW -100 -W OR APPROVED EQUAL. COORDINATE AUTO /MANUAL SETTINGS WITH OWNER. PROVIDE DUAL BALLAST IN FIXTURE TO TURN ONE BULB ON /OFF INDEPENDENTLY OF THE OTHER. PROVIDE EXTERIOR FIXTURE WITH INTERNAL PHOTOCELL FOR AUTOMATIC OPERATION. PROVIDE INTEGRAL EMERGENCY BATTERY BACKUP. PROVIDE SUITABLE TIMECLOCK DOWN STREAM OF SITE/EXTERIOR PHOTOCELL FOR CONTROL OF DAWN TO DUSK SHUTOFF TIME PHOTOCELL TO TURN ON LIGHTS AT DUSK. TIMECLOCK TO TURN OFF AT USER DESIGNATED TIME. 1-9 ENERGY CODE NOTES:, 1, ALL LIGHTING NOT INDICATED AS A 24 -HOUR NIGHT LIGHT SHALL BE CONTROLLED BY TIMECLOCK OR OCCUPANCY SENSORS. ALL LOCAL SWITCHES SHALL BE DOWNSTREAM OF AUTOMATIC CONTROLS. L1 P1 -9 2. COMMISSIONING REQUIREMENTS: IN ACCORDANCE WITH WSEC 1513.7, ALL AUTOMATIC LIGHTING CONTROLS (INCLUDING TIMERS & OCCUPANCY SENSORS) SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS, SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER. ELOO97S RECEIVED NOV 15 2010 PERMIT CENTER BrN Engineering, Inc. Electrlcel Consulting Engineering 2101 9th Avenue, Suite 215 tel: (206)223 -6446 Seattle, Washington 95121 fax:(206)223.6465 0) CO 11. Architecture EXPIRES 1 -17 -12 0 J co - O 17 I- C) Fami I1 (0 0 u; C. co LL V 0 DRAWING ISSUE BID SET: JULY 12, 2010 DRAWING TITLE LIGHTING PLAN SCALE: 1/4" =11 -0" PLOT DATE: JUN 72010 CAD FILE: E30.0.DWG PROJ. MGR.: ER DRAFTER: JG SHEET NO. E30.0 ...Silt/ A •■•■• k.LU.. nnw. _ Ahuavc Verifii Gmbh