Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0936 - WESTFIELD SOUTHCENTER MALL - PICTURE PEOPLE
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. El-1 0-0936 Picture People 111 Southcenter Mall RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 15 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. PICTURE PEOPLE 111 SOUTHCENTER MALL EL1O-0936 Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 111 SOUTHCENTER MALL TUKW Tenant Name: PICTURE PEOPLE ELECTRICAL PERMIT Permit Number: EL10 -0936 Issue Date: 01/03/2011 Permit Expires On: 07/02/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: BRIAN DONOVAN Address: 811 CROMWELL PK DR - SUITE 113 , GLEN BURNIE MD 21061 Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA 98032 Contractor License No: SEATAEI077RW Phone: 410 - 863 -1302 Phone: Expiration Date: 12/17/2011 DESCRIPTION OF WORK: INSTALLATION OF OUTLETS, DATA/TELEPHONE LINES, LIGHT FIXTURES AND AUDIO/VISUAL DEVICES Value of Electrical Work: NRES: $10,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $330.63 National Electrical Code Edition: 2008 Date: l��v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Print Name: 1-e6 "I1 Ywa,r/ Date: 01/4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL 10 -0936 Printed: 01 -03 -2011 PERMIT CONDITIONS Permit No. EL10 -0936 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-0936 Printed: 01 -03 -2011 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httd://wwweLtukwila.wa.us Project No. For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: 111 Southcenter Mall Suite Number: 728 Floor: 1 Tenant Name: The Picture People New Tenant: m Yes ❑..No Property Owners Name: The Picture People Mailing Address: 1800 10th Street Plano, TX 75074 City State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued. Name: Brian Donovan Mailing Address: E -Mail Address: 811 Cromwell Park Dr., Suite 113 bdonovan©l2m.com Day Telephone: (410) 863 -1302 Glen Burnie, MD City State Fax Number: (410) 863 -1302 21061 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 10,000 Scope of Work (please provide detailed information): Installation of outlets, data / telephone lines, light fixtures and audio / visual devices Will service be altered? ❑ Yes m No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change m Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy m Seattle City Light H :\Applications \Fors - Applications On Lane \2010 Applications \7 -2010 - Electncal Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) m Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: tiu 21u5 Mailing Address: W)(_-)Th 1 V ✓14A i i..- Day Telephone: 11/04 1 t& city Date: 1-)k state Zip Date Application Accepted: Date Application Expires: Staff Initials: H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 City of'Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site :'http: / /www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 111 SOUTHCENTER MALL TUKW Suite No: Applicant: PICTURE PEOPLE RECEIPT Permit Number: EL10 -0936 Status: APPROVED Applied Date: 11/17/2010 Issue Date: Receipt No.: R11 -00002 Initials: User ID: WER 1655 Payment Amount: $264.50 Payment Date: - Balance: 01/03/2011 10:38 AM $0.00 Payee: KEVIN HAYWARD TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. FINANCE ACCOUNT ITEM LIST: Description 264.50 Account Code Current Pmts ELECTRICAL PERMIT NONR City of Tukwila 6200 Southcenter Blvd, Tukwila, WA 1 Finance Department BR1 T121 1100301 -1 01/03L20I1 _ Mon Jan03,2011 10:43AM Trans #37 -37 37 $264.50 DCDGEN - DCD Permits Plus - General Fund ID: PICTURE PEOPLE Secondary ID: KEVIN HAYWARD 1 ITEM(S): TOTAL: $2646505 Visa www.ci.tukwila.wa.us 206 - 433 -1835 000.322.101.00.00 Total: $264.50 264.50 Printed: 01 -03 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: EL10 -0936 Address: 111 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/17/2010 Applicant: THE PICTURE PEOPLE Issue Date: Receipt No.: R10 -02324 Initials: WER User ID: 1655 Payment Amount: $66.13 Payment Date: 11/17 /2010 09:13 AM Balance: $264.50 Payee: L2M TRANSACTION LIST: Type Method Descriptio Amount Payment Check 13903 66.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 66.13 Total: $66.13 -1.•/\--126\ doc: Receiot -06 Printed: 11 -17 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 640-030 CITY OF TUKWILA BUILDING DIVISION 1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)'431 -3670 Permit Inspection Request Line (206) 431 -2451 a-- Project: Type of Inspection: NO Address: il n Date Called: Special Instructions: Date Wanted: ziez. a.m p.m Requester: ((( Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. 6711?)&10(45 m(P( f taNiktv- Inspector: Date: 0210211 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPE..TION NO. INSPECTION RECORD Retain a copy with permit 6.10413(, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: t qk c?60111.Type of Inspection:00 Address. 1 1 t li Date Called: Special Instructions: Date Wanted: \g? p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Qx thr rt'S C (ioNl> rdlleTP Aior6: - Priwf ®& et `Pci / O v coo) )c--0,4_5 1A1 etAl nazi° Inspector: O.Ur`� Date: lll� F-7 REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. fj,iO-O?3& 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: KeAvet P Type of Inspection: 7®6, O`K. 6LAA)C1 ea tiff\ Address: I l i 3� � Date Called: Special Instructions: Date Wanted: ::m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. . COMMENTS: O`K. 6LAA)C1 ea tiff\ &J4 iipi COPraer6 44; o i• r 'is Coy D gotiD Ar GJA Inspector: Date: ov /OA n REINSPECTION FEE REQUIRED. Prior to next inspectio , fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION N0. INSPECTION RECORD' Retain a copy with permit 4/O.936 PERMIT NO. uf CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100',. Tukwila, WA 98188 (206)431 -3670 Pro ect: Pow lei c -r“ 2s" Ptu -' Type of Inspection: 7 /3a3/ '%00/ Address: l / I 5DUTAe'' -r - /44Lt_ Date Called: .-• Special Instructions:" \ k Date Wanted: / '10 -il a.m. p.m. Requester: Phone No: ,--'% ./' e-?,► 're r , 57, ir-rfi 7- WApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: /- L.J/a4 L 2- 0/e ,--'% ./' e-?,► 're r , 57, ir-rfi 7- ')ov/ /., 2,e Pv c „1-7, 1:-;r 4i /v> 2 CA.S19 R,7- 7s°rd.■,z s- Inspector. �-n n Y 8uxN.D'7 Date: i- /g-// El $60.00 INSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1;4." 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: flailikf VeatetType of Inspection: Address: 11 flatUV Date Called: Special Instructions: Date Wanted: 4 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - ice Inspector: Aloc n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0( 113 ' • • W COP'S PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0936 DATE: 11 -17 -10 PROJECT NAME: PICTURE PEOPLE SITE ADDRESS: 111 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: J WC1 1\cIo Building Division Public Works Fire Prevention Structural Planning Division 111 Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-18-10 Complete Comments: Incomplete Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 12 -16 -10 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page • Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name SEA TAC ELECTRIC INC UBI No. 601510212 Phone 2538725553 Status Active Address 7056 S 220Th St License No. SEATAEI077RW Suite /Apt. License Type Electrical Contractor City Kent Effective Date 12/16/1993 State WA Expiration Date 12/17/2011 Zip 98032 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ociated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATAEC131QC SEA-TAC ELECTRICAL CONTRACTORS Electrical Contractor General Unused 11/3/1987 11/3/1995 Archived Master Electrician INFORMATION License HARGRT *974CD Name HARGREAVES, TOM Status Active Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM Agent 12/17/1993 Bond Amount HARGREAVES, TOM President 12/17/1993 798649C BEAN, ERIC Secretary 12/10/2008 BEAN, ERIC Treasurer 12/10/2008 MERCHANTS BONDING CO (MUTUAL) JORDAN, TOM Vice President 01/01/2002 01/22/2009 HARGREAVES, KATHERINE Secretary 12/17/1993 12/10/2008 BURKS, ROY Vice President 12/17/1993 12/15/1995 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 DEVELOPERS SURETY & INDEM CO 798649C 12/16/2008 Until Cancelled $4,000.00 $4,000.0012/03/2008 5 MERCHANTS BONDING CO (MUTUAL) WA11373 12/16/2004 Until Cancelled 01/22/2009 $4,000.0012/17/2004 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 12/16/1993 Until Released Bond $4,000.00 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type https://fortress.wa.gov/lni/bbip/Print.aspx 01/03/2011 • SWITCH BANK DETAIL N.T.S. NOTE: SWITCHES SHALL BE INSTALLED BETWEEN STUDS MAKE (2) ROWS IF NECESSARY, DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. GENERAL NOTES A. THE TENANT SHALL PROVIDE ALL FIXTURES AND LAMPS, TRACK AND PIPING. THE TENANT'S ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS, TRACK AND PIPING AND COMPONENTS TO PROVIDE A COMPLETE LIGHTING SYSTEM. ANY MISCELLANEOUS ITEMS NECESSARY FOR HANGING OR SUPPORTING THE TRACK AND FIXTURES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. B. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURES, SUPPORTS, ETC. SHALL BE FASTENED TO THE TOP CHORD OF JOISTS OR BEAMS ONLY. DO NOT SUPPORT FROM METAL DECKING OR MECHANICAL DUCTWORK. TENANT'S ELECTRICAL CONTRACTOR SHALL REPAIR ANY FIREPROOFING DISTURBED BY ATTACHMENTS TO THE STRUCTURE. C. COORDINATE ALL WORK WITH OTHER TRADES. VERIFY CEILING HEIGHTS AND TYPE, CASEWORK INSTALLATION, SIGN LOCATION, ETC WITH ARCHITECTURAL PLANS AND DETAILS FOR RELATED WORK. D. NIGHT, EMERGENCY AND EXIT LIGHTING SHALL NOT BE SWITCHED. E. TENANT'S ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION WITH LANDLORD THE EXACT LOCATION AND REQUIREMENTS OF POWER, COMMUNICATION AND FIRE ALARM SYSTEM TIE —INS. F. ELECTRICAL CONTRACTOR SHALL BE PRESENT WITH THE TENANT CONSTRUCTION MANAGER IN ORDER TO AIM ALL TRACK LIGHT COMPONENTS THROUGH THE STORE PER THE TENANT CONSTRUCTION MANAGER'S DIRECTION. SEPARATE PERMIT REQUIRED FOR; rMichanics, 0 Electrical (numbing Was Piping City of Tukwila EL1,1 '1NG DIVISION 01 PLAN KEY NOTES 1. INSTALL SPEAKERS (PROVIDED BY GENERAL CONTRACTOR), #16 AWG PLENUM SPEAKER WIRE, IN 1/2" CONDUIT IN WALLS. HOME RUN FOR EACH SPEAKER TO J —BOX UNDER MANAGER AREA IN BACK ROOM. SEE SHEET E -201 FOR LOCATION OF J— BOX, COIL 10' IN J —BOX. 2. AUTOMATIC SWITCH, LEVITON #002— ODS10 —IDW, OCCUPANCY SENSOR AUTOMATIC WALL SWITCH. SET TIMING SO LIGHT AND FAN TURNS OFF AFTER 120 SECONDS. 3. PROVIDE SIGNAGE CIRCUIT, COORDINATE ALL REQUIREMENTS WITH SIGNAGE PROVIDER AND LANDLORD AND CONNECT IN A CONCEALED MANNER. 4. SWITCHBANK LOCATION. SEE DETAIL. STACK GROUPS IF REQUIRED BY WALL SPACE. 5. EXHAUST FAN 6. THIS FIXTURE SHALL BE INTERLOCKED WITH WALL SWITCH. INSTALLED UNDER SHELL BUILDING CONTRACT. F L Permit No., )LSD" COPY O33 IP Plan review approval is suileci to ernars and missions. kp ;rovat of construction documents does not authorize is violation of any : dopted • , : or ordinance. Receipt o► approved Fie • , ; �, acknowledged: By , f1 r City Of'bkwila BUILDING DIVISION REVISIaIVg No changes shall am d to the scope of work without prior approval of NOTE: FiavisionsiwilSl re Ildin g Division. and may include additional pl n�rev lan ew f es.ttal LIGHTING PLAN SCALE: 1/4"=1'— 0" —REVIEWED it1WLU4PICE WITH NFPA70 -NEC NUV 3 0 2010 Jam. u�1 of Tukwila BUILDING DIVISI N RECEIVED NOV 17 2010 PERMIT CENTER oq3' • /1A;ti L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2MCOL2M.com Phone 410.863.1302 Fax 410.863.1308 LUMINAIRE SCHEDULE TAG DESCRIPTION MANUFACTURER VOLTS LAMPS WATTAGE REMARKS A INCAND. ADJ. ACCENT LIGHT PIPE MOUNTED W /ACCESSORIES & TRACK OR MONO — POINT- LITON #LT815W &TRACK W /ACCESSORIES OR #LT971W W /ACCESSORIES 120 1- 75PAR30 /NFL30 75 SEE DETAIL AND PLAN HEAD PLACEMENT AS INDICATED WITH MISC. TRACK ACCESSORIES B 6" RECESSED METAL HALIDE DOWNLIGHT WITH SPECULAR ALZAK CONE LITON #LHM7070E W / #LR711C & #C260 120 1— MH70 /U /MED 70 — C 2 FT X 4 FT, 2 —LAMP FLUORESCENT W /ACRYLIC LENS LIGHTOLIER #XT2GVA24012003 120 2— F032/835/ECO 59 FIXTURE CONTROLLED WITH DUAL SWITCHING AND DUAL BALLASTS X CEILING MOUNTED, EDGE LIT, LED EXIT SIGN ROYAL PACIFIC RXL11RW 120 INCLUDED 4 FIXTURE SHALL BE UNSWITCHED XE LED EXIT AND EMERGENCY LIGHT WITH BATTERY BACK —UP ROYAL PACIFIC RXEL18RW 120 INCLUDED 4 FIXTURE SHALL BE UNSWITCHED EM SEMI — RECESSED IN CLG. EMERG. LIGHT W /LAMPS & BATTERY BACK —UP LIGHTOLIER #C1182S9 120 INCLUDED 20 FIXTURE SHALL BE UNSWITCHED ** 'D' IN SQUARE COVE ABOVE POS STATION, USE 2 —LAMP STRIP 'D1' WITHOUT TUBE COVERS. NOTES: ALL TRACK FIXTURES SHALL BE COORDINATED WITH ARCHITECT AND TENANT PROVIDED COMPONENTS. NOT ALL FIXTURES SHOWN ON THIS SCHEDULE ARE REQUIRED. REFER TO LIGHTING PLAN, THIS SHEET, FOR FIXTURES THAT APPLY TO THIS PROJECT. SWITCH BANK DETAIL N.T.S. NOTE: SWITCHES SHALL BE INSTALLED BETWEEN STUDS MAKE (2) ROWS IF NECESSARY, DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. GENERAL NOTES A. THE TENANT SHALL PROVIDE ALL FIXTURES AND LAMPS, TRACK AND PIPING. THE TENANT'S ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS, TRACK AND PIPING AND COMPONENTS TO PROVIDE A COMPLETE LIGHTING SYSTEM. ANY MISCELLANEOUS ITEMS NECESSARY FOR HANGING OR SUPPORTING THE TRACK AND FIXTURES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. B. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURES, SUPPORTS, ETC. SHALL BE FASTENED TO THE TOP CHORD OF JOISTS OR BEAMS ONLY. DO NOT SUPPORT FROM METAL DECKING OR MECHANICAL DUCTWORK. TENANT'S ELECTRICAL CONTRACTOR SHALL REPAIR ANY FIREPROOFING DISTURBED BY ATTACHMENTS TO THE STRUCTURE. C. COORDINATE ALL WORK WITH OTHER TRADES. VERIFY CEILING HEIGHTS AND TYPE, CASEWORK INSTALLATION, SIGN LOCATION, ETC WITH ARCHITECTURAL PLANS AND DETAILS FOR RELATED WORK. D. NIGHT, EMERGENCY AND EXIT LIGHTING SHALL NOT BE SWITCHED. E. TENANT'S ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION WITH LANDLORD THE EXACT LOCATION AND REQUIREMENTS OF POWER, COMMUNICATION AND FIRE ALARM SYSTEM TIE —INS. F. ELECTRICAL CONTRACTOR SHALL BE PRESENT WITH THE TENANT CONSTRUCTION MANAGER IN ORDER TO AIM ALL TRACK LIGHT COMPONENTS THROUGH THE STORE PER THE TENANT CONSTRUCTION MANAGER'S DIRECTION. SEPARATE PERMIT REQUIRED FOR; rMichanics, 0 Electrical (numbing Was Piping City of Tukwila EL1,1 '1NG DIVISION 01 PLAN KEY NOTES 1. INSTALL SPEAKERS (PROVIDED BY GENERAL CONTRACTOR), #16 AWG PLENUM SPEAKER WIRE, IN 1/2" CONDUIT IN WALLS. HOME RUN FOR EACH SPEAKER TO J —BOX UNDER MANAGER AREA IN BACK ROOM. SEE SHEET E -201 FOR LOCATION OF J— BOX, COIL 10' IN J —BOX. 2. AUTOMATIC SWITCH, LEVITON #002— ODS10 —IDW, OCCUPANCY SENSOR AUTOMATIC WALL SWITCH. SET TIMING SO LIGHT AND FAN TURNS OFF AFTER 120 SECONDS. 3. PROVIDE SIGNAGE CIRCUIT, COORDINATE ALL REQUIREMENTS WITH SIGNAGE PROVIDER AND LANDLORD AND CONNECT IN A CONCEALED MANNER. 4. SWITCHBANK LOCATION. SEE DETAIL. STACK GROUPS IF REQUIRED BY WALL SPACE. 5. EXHAUST FAN 6. THIS FIXTURE SHALL BE INTERLOCKED WITH WALL SWITCH. INSTALLED UNDER SHELL BUILDING CONTRACT. F L Permit No., )LSD" COPY O33 IP Plan review approval is suileci to ernars and missions. kp ;rovat of construction documents does not authorize is violation of any : dopted • , : or ordinance. Receipt o► approved Fie • , ; �, acknowledged: By , f1 r City Of'bkwila BUILDING DIVISION REVISIaIVg No changes shall am d to the scope of work without prior approval of NOTE: FiavisionsiwilSl re Ildin g Division. and may include additional pl n�rev lan ew f es.ttal LIGHTING PLAN SCALE: 1/4"=1'— 0" —REVIEWED it1WLU4PICE WITH NFPA70 -NEC NUV 3 0 2010 Jam. u�1 of Tukwila BUILDING DIVISI N RECEIVED NOV 17 2010 PERMIT CENTER oq3' • /1A;ti L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2MCOL2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER s a THE PICTURE PEOPLE 180010TH STREET SUITE 300 PLANO, TX 75074 s b s c S d SWITCH BANK DETAIL N.T.S. NOTE: SWITCHES SHALL BE INSTALLED BETWEEN STUDS MAKE (2) ROWS IF NECESSARY, DO NOT CUT STUDS TO ACCOMMODATE A SINGLE ROW OF SWITCHES. GENERAL NOTES A. THE TENANT SHALL PROVIDE ALL FIXTURES AND LAMPS, TRACK AND PIPING. THE TENANT'S ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS, TRACK AND PIPING AND COMPONENTS TO PROVIDE A COMPLETE LIGHTING SYSTEM. ANY MISCELLANEOUS ITEMS NECESSARY FOR HANGING OR SUPPORTING THE TRACK AND FIXTURES SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. B. CONDUIT HANGERS, CLAMPS, LIGHT FIXTURES, SUPPORTS, ETC. SHALL BE FASTENED TO THE TOP CHORD OF JOISTS OR BEAMS ONLY. DO NOT SUPPORT FROM METAL DECKING OR MECHANICAL DUCTWORK. TENANT'S ELECTRICAL CONTRACTOR SHALL REPAIR ANY FIREPROOFING DISTURBED BY ATTACHMENTS TO THE STRUCTURE. C. COORDINATE ALL WORK WITH OTHER TRADES. VERIFY CEILING HEIGHTS AND TYPE, CASEWORK INSTALLATION, SIGN LOCATION, ETC WITH ARCHITECTURAL PLANS AND DETAILS FOR RELATED WORK. D. NIGHT, EMERGENCY AND EXIT LIGHTING SHALL NOT BE SWITCHED. E. TENANT'S ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION WITH LANDLORD THE EXACT LOCATION AND REQUIREMENTS OF POWER, COMMUNICATION AND FIRE ALARM SYSTEM TIE —INS. F. ELECTRICAL CONTRACTOR SHALL BE PRESENT WITH THE TENANT CONSTRUCTION MANAGER IN ORDER TO AIM ALL TRACK LIGHT COMPONENTS THROUGH THE STORE PER THE TENANT CONSTRUCTION MANAGER'S DIRECTION. SEPARATE PERMIT REQUIRED FOR; rMichanics, 0 Electrical (numbing Was Piping City of Tukwila EL1,1 '1NG DIVISION 01 PLAN KEY NOTES 1. INSTALL SPEAKERS (PROVIDED BY GENERAL CONTRACTOR), #16 AWG PLENUM SPEAKER WIRE, IN 1/2" CONDUIT IN WALLS. HOME RUN FOR EACH SPEAKER TO J —BOX UNDER MANAGER AREA IN BACK ROOM. SEE SHEET E -201 FOR LOCATION OF J— BOX, COIL 10' IN J —BOX. 2. AUTOMATIC SWITCH, LEVITON #002— ODS10 —IDW, OCCUPANCY SENSOR AUTOMATIC WALL SWITCH. SET TIMING SO LIGHT AND FAN TURNS OFF AFTER 120 SECONDS. 3. PROVIDE SIGNAGE CIRCUIT, COORDINATE ALL REQUIREMENTS WITH SIGNAGE PROVIDER AND LANDLORD AND CONNECT IN A CONCEALED MANNER. 4. SWITCHBANK LOCATION. SEE DETAIL. STACK GROUPS IF REQUIRED BY WALL SPACE. 5. EXHAUST FAN 6. THIS FIXTURE SHALL BE INTERLOCKED WITH WALL SWITCH. INSTALLED UNDER SHELL BUILDING CONTRACT. F L Permit No., )LSD" COPY O33 IP Plan review approval is suileci to ernars and missions. kp ;rovat of construction documents does not authorize is violation of any : dopted • , : or ordinance. Receipt o► approved Fie • , ; �, acknowledged: By , f1 r City Of'bkwila BUILDING DIVISION REVISIaIVg No changes shall am d to the scope of work without prior approval of NOTE: FiavisionsiwilSl re Ildin g Division. and may include additional pl n�rev lan ew f es.ttal LIGHTING PLAN SCALE: 1/4"=1'— 0" —REVIEWED it1WLU4PICE WITH NFPA70 -NEC NUV 3 0 2010 Jam. u�1 of Tukwila BUILDING DIVISI N RECEIVED NOV 17 2010 PERMIT CENTER oq3' • /1A;ti L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2MCOL2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER 4201 West Gray Street : Tampa, Florida 33609 Telephone: (813) 287 -2719 Fax: (813) 287 -5704 `49` V1 NoN it �,r";».nhri ,1'.: 1`1r� r a�11+ � '� rn' g co' THE PICTURE PEOPLE 180010TH STREET SUITE 300 PLANO, TX 75074 - N 1) REV. # ISSUE 1 DESCRIPTION DATE PERMIT 11/03/10 SHEET TITLE: LIGHTING PLAN, LUMINAIRE SCHEDULE DRAWING DATE: 08 OCT 10 DRAWN BY: DW REVIEWED BY: DW /HH PROJECT # 10.281 SHEET I E.101 FILE NAME: 10281 E1.dwg • n1 1" a 1 N t0 TELEPHONE PATCH SERVER _BALLS_ EP 2" POS JJ^ COMMUNICATION PROVISIONS RISER TYPICAL MOUNTING HEIGHTS N.T.S. FURNISHED WITH UNIT SEE PANEL SCHEDULE MECH. EQUIP. POWER WIRING DETAILS N.T.S. NOTES: 1. ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT, CIRCUIT BREAKER, ASSOCIATED WIRING' AND CONDUIT WITH MECHANICAL SHOP DRAWINGS PRIOR TO ORDERING ELECTRICAL EQUIPMENT. IF SIZE(S) OF ELECTRICAL EQUIPMENT REQUIRED DIFFERS FROM WHAT IS INDICATED ON ELECTRICAL PLANS, NOTIFY ELECTRICAL ENGINEER OF CHANGES. 2. DO NOT LOCATE DISCONNECT SWITCHES OVER UNIT ACCESS PANELS. 3. PROVIDE A 3/4" EMPTY CONDUIT THROUGH INACCESSIBLE LOCATIONS (I.E. WALLS, UNDER SLAB) FOR CONTROL WIRING. COORDINATE WITH MECHANICAL PLANS. 4. ELECTRICAL DESIGN IS BASED ON THE MANUFACTURER AND MODEL NUMBER LISTED ON THE MECHANICAL PLANS. IF THERE IS AN EQUAL OR ALTERNATE MANUFACTURER PROVIDED, THE MECHANICAL /GENERAL CONTRACTOR SHALL BEAR ANY AND ALL ADDITIONAL COST RELATED TO THE ELECTRICAL CHANGES ASSOCIATED WITH SUCH SUBSTITUTIONS. 5. ELECTRICAL CONTRACTOR SHALL INSTALL ALL STARTERS FURNISHED BY MECHANICAL CONTRACTOR UNLESS STARTERS ARE SPECIFICALLY NOTED ON MECHANICAL PLANS TO BE FACTORY INSTALLED (SEE NOTE 4). MAKE ALL FINAL CONNECTIONS. 42" AFF AFF SELLING STATION A -2 MOH OPP1 GENERAL NOTES A. ELECTRICAL CONTRACTOR SHALL COORDINATE DATA /PHONE /POWER OUTLET LOCATIONS WITH CASEWORK OPENINGS. SEE CASEWORK FIXTURE SHEETS PRIOR TO ROUGH —IN. B. COORDINATE ALL WORK WITH OTHER TRADES. VERIFY CEILING HEIGHTS AND TYPE, CASEWORK INSTALLATION, SIGN LOCATION, ETC., WITH ARCHITECTURAL PLANS AND DETAILS FOR RELATED WORK. INSTALLATION, SIGN LOCATION, ETC., WITH ARCHITECTURAL PLANS AND DETAILS FOR RELATED WORK. C. ALL DUPLEX RECEPTACLES SHALL BE 20 AMPS, UNLESS OTHERWISE NOTED. ALL ISOLATED GROUND RECEPTACLES SHALL BE HUBBELL #IG- 5362 —OR AND BE GROUNDED AT TRANSFORMER WITH EQUIPMENT GROUND. D. FIRE ALARM SYSTEM (IF APPLICABLE) SHALL BE AN EXTENSION OF THE EXISTING LANDLORD SYSTEM. LANDLORD'S FIRE ALARM CONTRACTOR MUST INSPECT AND OR PERFORM ALL WORK INCLUDING RELOCATION OF CEILING SMOKE DETECTORS AND TESTING. PROVIDE ALL DEVICES INDICATED MATCHING SYSTEM AND ALL EQUIPMENT AND CONNECTIONS PER LANDLORD REQUIREMENTS. E. PROVIDE DUCT DETECTORS AS LOCATED ON MECHANICAL DRAWINGS. F. CEILING RECEPTACLES FOR STUDIOS AND COMMUNICATION OUTLETS ARE INDICATED ON SHEET E -101 FOR COORDINATION. SEE SHEET E -101 FOR LOCATIONS AND CIRCUITS. CEILING RECEPTACLES AND PLATES SHALL BE WHITE OR MATCH CEILING. PROVIDE 2" CONDUIT ROUTED ABOVE ANY SECTIONS OF INACCESSIBLE CEILING FOR PLASMA CABLES (TYPICAL). G. ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION WITH LANDLORD THE EXACT LOCATION OF POWER, COMMUNICATION AND OTHER SYSTEM TIE —INS. A-32 0I PLAN KEY NOTES 1. SALES COUNTER OUTLETS SHALL BE HUBBELL IG -5362 RECEPTACLES AND COMMUNICATION OUTLETS AND COORDINATED WITH OWNER AND MILLWORK DRAWINGS. RECEPTACLES AND COMMUNICATIONS OUTLETS SHALL BE PROVIDED AND INSTALLED BY CONTRACTOR. 2. SAW CUT FLOOR AS REQUIRED FOR INSTALLATION OF CONDUIT. PROVIDE (1) 2 "C FOR DATA TO ACCESSIBLE CEILING FOR COMMUNICATIONS CABLES, POWER CONDUIT SHALL BE 1 " COORDINATE COMMUNICATIONS WIRING BY OWNER, PROVIDE CONNECTIONS TO MC CABLE WITH GROUND FOR RECEPTACLE CIRCUITS IN MILLWORK. PATCH FLOOR AS REQUIRED. COORDINATE WITH GENERAL CONTRACTOR PRIOR TO CUTTING AND PATCHING. CONTRACTOR SHALL SUPPLY THE FOLLOWING FOR THE PROCESSOR, RECEPTACLE NEMA L5 -20R TWIST LOCK; PLUG, NEMA L5 -20P (PLUG SHALL BE WIRED SINGLE PHASE WITH A GROUND); WIRE, EIGHTEEN LINEAR FEET OF 600 V. CAROL 12/2 90 DEGREES C, L WATER RESISTANT SOW CSA ( -40 DEGREES C) FT- 2P -7K- 1030033 —MSHA WIRE. WIRE THE MALE CONNECTOR PLUG FOR THE PHOTO LAB UNIT. ALSO SUPPLY A STANDARD 20 AMP OUTLET NEMA 5 -20R. BOTH RECEPTACLES SHALL BE IN METAL POWER POLE WHEN RECEPTACLES ARE INDICATED AT THE UNIT AS AN ISLAND, NOT IN A WALL. COORDINATE LOCATION. ELECTRIC WATER HEATER CONNECTION. COORDINATE EXACT LOCATION WITH PLUMBING CONTRACTOR AND MECHANICAL DRAWINGS. 5. PROVIDE J —BOX AT 18 "- A.F.F. WITH PULL STRING TO BE USED FOR SPEAKER WIRES, GENERAL CONTRACTOR TO CONNECT SPEAKERS. 6. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT. 7. SERVER RECEPTACLES SHALL BE HUBBELL (2) NEMA 5 -20R,' 20 AMP MOUNTED 18" A.F.F. PROVIDE A SEMI — RECESSED METAL WIRING GUTTER WITH 4 "X4" OPENINGS FOR CABLING BY TENANT. ALL PER COMM. PROVISIONS RISER. TROUGH MOUNTED AT 90" A.F.F. (ABOVE TELEPHONE BACKBOARD). 8. RECEPTACLE FOR SELLING STATION OR SCANNER, USE DEDICATED NEUTRAL AND COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS. 9. FLUSH MOUNTED JUNCTION BOX FOR HAND DRYER. MOUNT AT 48" A.F.F. VERIFY MOUNTING HEIGHT WITH GENERAL CONTRACTOR PRIOR TO ROUGH -IN. 10. RIGID CONDUIT FROM PHONE /DATA OUTLET IN WALL AND UP TO 6" ABOVE CEILING. A -26 CIS IG IG —DOOR CHIME MOUNTED 6" -BELOW CEILING-PROVIDE- LOW VOTIT^ACE WIRING 'TO POSH BUTTON AT SERVICE i = =__ TRANSFORMER MOUNTED ABOVE CEILING SHALL BE COMPATIBLE WITH BUZZER AND DOOR CHIME PUSH BUTTON MOUNTED AT 48" A.F.F. HEATH ZENIT #SL6164. POWER PLAN SCALE: 1/4"=1'— 0" ELt&o3b REVIEWED .F014- COMPLIANCE WITH NFPA 70 - NEC NOV 3 0 2010 BUILDING DIVISIQN RECEIVED NOV 17 2010 PERMITCENTER L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2M@L2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER 4201 West Gray Street : Tampa, Florida 33609 Telephone: (813) 287 -2719 Fax: (813) 287 -5704 I 0, I � .v . S� \. A�., 3, u? i 4,Z l wt • iii �'� ""' ..E 4 ‘'kltt: • H THE PICTURE PEOPLE 1800 10TH STREET SUITE 300 PLANO, TX 75074 N /0 REV, # ISSUE /DESCRIPTION DATE PERMIT 11/03/10 SHEET TITLE: POWER PLAN DRAWING DATE: 08 OCT 10 DRAWN BY: DW REVIEWED BY: DW /HH PROJECT # 10.281 SHEET # E.201 FILE NAME: 10281 E2.dwg I THE PICTURE PEOPLE TYPICAL ELECTRICAL, DATA AND VOICE WIRING REQUIREMENTS CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER 24 PORT CAT 6 PATCH PANEL WITH BRACKETS 4201 West Gray Street : Tampa, Florida 33609 Telephone: (813) 287 -2719 Fax: (813) '287 -5704 Ik t■ ; t c, �Og. a — •;k....0 Gil 4.'�:" is .. � GENERAL NOTES FRONT SALES T S 1 QUAD POWER OUTLET (NEMA 5 -15R) PER SELLING STATION LOCATION. 1 CAT 6 DATA DROP PE R SELLING STATION LOCATION T 1 DEDICATED 15 AMP CIRCUIT PER EACH SET OF 2 SELLING STATIONS . . i • • A ON R • PORT 1 LABEL: CIS PORT 2 LABEL: LPF1 PORT 3 LABEL: SS1 PORT 4 LABEL: SS2 PORT 5 LABEL: SS3 PORT 6 LABEL: SS4 PORT 7 LABEL: SS5 PORT 8 LABEL: SS6 PORT 9 LABEL: B01 PORT 10 LABEL: PP1 PORT 11 LABEL: PP2 ( INSTALL ONLY IF THE STUDIO IS RECEIVING 2 PHOTO PRINTERS) PORT 12 LABEL: LPB1 PORT 13 LABEL: X01 PORT 14 LABEL: CR PORT 15 LABEL: NONE LEAVE BLANK PORT 16 LABEL: NONE LEAVE BLANK PORT 17 LABEL: NONE LEAVE BLANK PORT 18 LABEL: NONE LEAVE BLANK PORT 19 LABEL: NONE LEAVE BLANK PORT 20 LABEL: NONE LEAVE BLANK PORT 21 LABEL: NONE LEAVE BLANK PORT 22 LABEL: NONE LEAVE BLANK PORT 23 LABEL: BUM (NEED TO CONVERT TO RJ11 FROM RJ45) PORT 24 LABEL: T1 OR DSL (DEPENDING ON THE TYPE OF DIGITAL LINE T1 OR DSL THAT WILL BE THE LABEL FOR PORT 24) NOTE: THE CORRESPONDING JACK SHOULD HAVE THE SAME LABEL DESIGNATION A. B. C. PLEASE BID ALL PICTURE PEOPLE PROJECTS BY ADDRESSING THE TELECOMMUNICATIONS BEING SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. IF FURTHER INFORMATION IS REQUIRED, PLEASE CONTACT THE PROJECT CONTACT ON SHEET A -000 OR THE PROJECT COORDINATOR. TELECOMMUNICATION SCOPE OF WORK SHOULD NOT BE EXCLUDED OR QUALIFIED AS EXCLUDED IN THE PROJECT BID ESTIMATE. WIRE SPEAKERS BACK TO J —BOX AT PRINTING AREA. SEE KEY NOTE #5 ON SHEET E -201. PLEASE CONTACT THE PICTURE PEOPLE FOR THE COMPLETE SCOPE OF WORK FOR DATA AND COMMUNICATIONS. SEE A -000 FOR CONTACT PERSON. 1 DEDICATED 15 AMP CIRCUIT QUAD POWER OUTLETS (NEMA 5 -15R) PER NORITSU DDP 610 PHOTO PRINTER. FOR NORITSU 3202 PHOTO PRINTER SEE NANCY RACITI. POWER OUTLET SHOULD BE INSTALLED WHERE PRINTER IS (1 -2) CAT 6 DATA DROPS. THIS NUMBER IS DEPENDANT ON THE NUMBER OF PHOTO PRINTERS BEING INSTALLED. POWER OUTLET SHOULD BE INSTALLED WHERE PRINTER IS LOCATED. PRINTER LOCATION VARIES PER STUDIO. IN CERTAIN STUDIOS THE PHOTO PRINTER MAY BE LOCATED IN THE MIDDLE FLOOR SPACE OF THE BACK OFFICE AND NOT NECESSARILY INSTALLED AGAINST THE WALL. IF THIS IS THE CASE A POLE WILL NEED TO BE INSTALLED COME DOWN FROM THE CEILING WITH POWER AND DATA DROP PP1 & PP2. PP2 WILL ONLY BE INSTALLED IF THE STUDIO WILL BE INSTALLED WITH 2 PHOTO PRINTERS. TELECOM BACKBOARD 1 NEMA 5 -15R) DEDICATED CIRCUIT WITH (2) QUAD POWER OUTLETS PER CHECK IN / POS STATION 2 CAT 6 DATA DROPS PER CHECK IN / POS LOCATION (XT10, AND XT11) 2 CAT 6 VOICE DROPS WITH RJ11 CONNECTIONS. ON ONE SET OF WIRES THE BROWN WIRE SHOULD BE SPLIT OFF AND AN RJ11 JACK ADDED FOR THE GIFT CARD READER. THESE VOICE JACKS SHOULD BE A DIFFERENT COLOR THAN THE DATA PORTS. TERMINATION FOR VOICE CABLES SHOULD BE ON A 66 BLOCK AT THE TELEPHONE BACK BOARD (GCR) CAMER ROOM (TYPICAL OF 3 ROOMS) ASSUMPTION IS THAT THE TELEPHONE BACKBOARD EXISTS IN THE STUDIO WITH (1) 66 BLOCK TO BE USED BY THE LOCAL TELCO VENDOR (LEC). THIS CONNECTION IS USUALLY PROVIDED BY THE MALL AND IS CONNECTED FROM THE MAIN TELEPHONE ROOM OF THE MALL TO THIS LOCATION. IF NOT PRESENT THE CABLING VENDOR SHALL PULL NEW CABLE AND TERMINATE ON BOTH ENDS TO A 66 BLOCK, I.E. STUDIO BACKBOARD AND MAIN TELEPHONE ROOM OF THE MALL. A SECOND 66 BLOCK TO TERMINATE THE VOICE STATION CABLES. , (1) CAT 6 CABLE FROM PORT 24 OF THE PATCH PANEL TO THE TELEPHONE BACKBOARD. AT THE BACKBOARD THE CABLE WITH AN RJ45 CONNECTOR SHOULD BE LEFT COILED AND LABELED AS PORT 24. (1) CAT 6 CABLE FROM PORT 23 OF THE PATCH PANEL TO THE TELEPHONE BACKBOARD. AT THE BACKBOARD THE CABLE SHOULD BE PUNCHED DOWN TO AN RJ11 BISCUIT BLOCK LABELED CISCO BACK —UP MODEM. ON PORT 23 OF THE PATCH PANEL THE CONNECTION WILL NEED TO BE CONVERTED TO AN RJ11 CONNECTION AND LABELED AS BUM (BACK UP MODEM). ITQUAD POWER OUTLETS (NEMA 5 -15R) TO BE LOCATED BELOW THE BACKBOARD TO BE (1) DEDICATED T15CAMPQCIRCUIT IRCU. DATA DROP WALL PLATE LABELS FRONT OFFICE 1 DUPLEX OUTLET MTD FOR BACKDROP —SEE REFLECTED CEILING PLAN 1 CEILING MTD DUPLEX OUTLET FOR HAIR LIGHT— SEE REFLECTED CEILING PLAN ET FOR PHOTOGRAPHERS UMBRELLA— SEE REFLECTED 1 CEILING MTD DUPLEX OUTLET SEE REFLECTED CEILING PLAN O 1 DUPLEX OUTLET (NEMA 5 -15R) 1 CAT 6 DATA DROP BACK OFFICE COUNTER AREA DATA DROPS TO BE SPREAD OUT IN THE WORK TABLE AREA OF THE BACK OFFICE SIDE BY SIDE WITH QUAD POWER OUTLETS (NEMA 5 -15R) PER DATA DROP. 3 CAT 6 DATA DROPS (BACK OFFICE COMPUTER AND LASER PRINTER). (1) CAT 6 VOICE DROP WITH RJ11 CONNECTION. THE BROWN WIRE SPLIT OFF FOR MUSIC ON HOLD AND TERMINATED WITH AN RCA JACK. THIS VOICE JACK SHOULD BE A DIFFERENT COLOR THAN THE DATA PORTS. TERMINATION FOR VOICE CABLE SHOULD BE ON A 66 BLOCK AT THE TELEPHONE BACK BOARD (MOH) PATCH PANEL PLACEMENT CIS — FOR CHECK IN / POS STATION 1 (LOCATED UNDER CASHWRAP) LPF1 — LASER PRINTER FRONT 1 (LOCATED UNDER CASHWRAP) SS1 — FOR SELLING STATION 1 SS2 — FOR SELLING STATION 2 SS3 — FOR SELLING STATION 3 — SS4 FOR SELLING STATION 4 SS5 — FOR SELLING STATION 5 SS6 — FOR SELLING STATION 6 BACK OFFICE (1) 24 PORT CAT 6 DATA PATCH PANEL WITH MOUNTING BRACKETS PATCH PANEL MUST BE MOUNTED AT 7' -6" ABOVE THE FLOOR. PATH SERVER RACK / STORAGE CABINET A SERVER RACK WILL BE PROVIDED BY THE PICTURE PEOPLE. NET WEIGHT 255.00 LBS. (115.91 KG) MAXIMUM HEIGHT 51.70 INCHES (1313 MM) MAXIMUM WIDTH 23.50 INCHES (597 MM) MAXIMUM DEPTH 42.20 INCHES (1072 MM) SHIPPING WEIGHT 301.00 LBS.( (136.82 KG) (1) DEDICATED AND ATER I0 AMP CIRCUIT H WITH QUAD POWER OUTLET (NEMA 5 -20R) FOR SERVER RACK THAT STORES SERVER B01 (WALL COUNTER) — BACK OFFICE SELLING STATION PP1 — PHOTO PRINTER 1 PP2 — PHOTO PRINTER 2 (INSTALL ONLY IF THE STUDIO IS RECEIVING 2 PHOTO PRINTERS) LPB1 (WALL COUNTER)— LASER PRINTER BACK 1 X01 (WALL COUNTER)— EXTRA DATA PORT XT12 ON ONE PORT (RJ11) AND MOH ON A SECOND PORT (RCA JACK). THESE VOICE DROPS SHOULD BE A DIFFERENT COLOR THAN THE DATA PORTS. STUDIO #3 STUDIO #2 DATA PLAN SCALE: 1 /4 " =1' -0" a1obc3b REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC NOV 3 0 2010 atymSwila BUILDING DIVISI • N RECEIVED NOV 17 2010 PERMIT CENTER /)? L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2M @L2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER 4201 West Gray Street : Tampa, Florida 33609 Telephone: (813) 287 -2719 Fax: (813) '287 -5704 Ik t■ ; t c, �Og. a — •;k....0 Gil 4.'�:" is .. � • N THE PICTURE PEOPLE 1800 10TH STREET SUITE 300 PLANO, TX 75074 - N 0 REV. # ISSUE/DESCRIPTION DATE PERMIT 11/03/10 SHEET TITLE: DATA PLAN DRAWING DATE: 08 OCT 10 DRAWN BY: DW REVIEWED BY: DW /HH PROJECT 1 10.281 SHEET I E-301 FILE NAME: 10281 E3 .dwg 4 TENANT SPACE TO LANDLORD'S FIRE ALARM SYSTEM RTU -1 Ci FIRE ALARM PARTIAL RISER DIAGRAM N.T.S. NOTES: 1. THIS DIAGRAM IS A GENERAL REPRESENTATION. REFER TO FLOOR PLANS FOR EXACT QUANTITY AND LOCATION OF DEVICES. 2. COORDINATE ALL WORK WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR. 3. TENANT'S CONTRACTOR SHALL PROVIDE AND INSTALL RACEWAY PER LANDLORD SYSTEM REQUIREMENTS. 4. TENANT'S CONTRACTOR SHALL INCLUDE COST OF TESTING AND PROGRAMMING OF ADDED DEVICES. COORDINATE WITH LANDLORD'S FIRE ALARM SYSTEM CONTRACTOR. 5. ALL WORK ON FIRE ALARM SYSTEM SHALL BE PERFORMED ONLY BY LANDLORD'S FIRE ALARM CONTRACTOR AND CONTRACTED AND PAID FOR BY TENANT'S CONTRACTOR. FIRE ALARM SYMBOL LEGEND al FIRE ALARM COMBINATION HORN /STROBE FIRE ALARM PULL STATION FIRE ALARM STROBE SHUT DOWN RELAY REMOTE LED DUCT SMOKE DETECTOR EX EXISTING DEVICE 0 0 0 1_0_s 0 0 LANDLORD'S ELECTRICAL LANDLORD'S EXISTING 480V METER CENTER TO REMAIN OImI LOCATION: PRINT ROOM MAIN: 225A MLO CONN. LOAD: 39.2 KVA VOLTAGE: 208Y/120V SYSTEM: 30, 4W FEED: TOP TRIM: SURFACE BUS RATING 225A GROUND''. BUS: YES OI. LOAD SERVED COND PHASE NEUT GND BKR Om LI O to 1 DMD BKR COND PHASE NEUT OII]I O 1 [1 1/2" #12 #12 #12 ® 1 1 0 1 I SS TENANT'S SPACE 0_ r) CO 0 0 N EXIST. GROUND --c> EXISTING POWER RISER DIAGRAM N.T.S. SERVICE RISER NOTES: 0 LANDLORD'S EXISTING 480Y/277V, 30, 4W METER CENTER TO REMAIN. 0 EXISTING 4 #3, 1 #8 E.G. IN 1 1/4” C. TO REMAIN. O EXISTING 4 #4/0, 1 #4 E.G. IN 2 1/2" C. TO REMAIN. O EXISTING PANELBOARD TO REMAIN. SEE PANEL SCHEDULE THIS SHEET. O EXISTING TIMECLOCK TO REMAIN. O PROVIDE NEW TIMECLOCK, TORK #W300L OR EQUAL BY INTERMATIC. EXISTING 75KVA TRANSFORMER TO REMAIN. FLOOR UPDATED: 11/3/2010 1:29 pm ISSUED FOR: APPROVAL EXISTING PANEL 'A'O EXIST. PANEL TO REMAIN LOCATION: PRINT ROOM MAIN: 225A MLO CONN. LOAD: 39.2 KVA VOLTAGE: 208Y/120V SYSTEM: 30, 4W FEED: TOP TRIM: SURFACE BUS RATING 225A GROUND''. BUS: YES CKT LOAD SERVED COND PHASE NEUT GND BKR DMD LI L2 L3 DMD BKR COND PHASE NEUT GND LOAD SERVED CKT 1 LTG: NIGHT /EMERG. /EXIT 1/2" #12 #12 #12 20/1 L R 20/1 1/2" #12 #12 #12 RECEPT: TELE. BACKBOARD 2 295 3 LTG: PRINT / RESTROOM 1/2" #12 #12 #12 20/1 L R 20/1 1/2" #12 #12 #12 RECEPT: CHANGING ROOM 4 3fi0 5 LTG: SALES 1/2" #12 #12 #12 20/1 L REVIEWED BY: DW /HH PROJECT 1l 10.281 SHEET i E-401 R 20/1 1/2" #12 #12.; #12 RECEPTS: PRINT ROOM /SALES 6 1080 7 LTG: STUDIO 1/2" #12 #12 #12 20/1 L 932 R 20/1 1/2" #12 #12 #12 RECEPT: MANAGER DESK 8 9 LTG: TRACK 1/2" #12 #12 #12 20/1 L 450 R 20/1 1/2" #12 #12 #12 RECEPT: SERVER 10 11 LTG: TRACK 1/2" #12 #12 #12 20/1 L R 20/1 1/2" #12 #12 #12 RECEPT: SERVER 12 600 13 LTG: TRACK 1/2" #12 #12 #12 20/1 L R 30/2 1/2" #10 #10 #10 PROCESSOR 14 2800 15 RECEPTS: CAMERA UMBRELLAS 1/2" #12 #12 #12 20/1 R R -, #10 16 2800 17 RECEPTS: CAMERA UMBRELLAS 1/2" #12 #12 #12 20/1 R R 20/1 1/2" #12 #12 #12 RECEPTS: RESTROOM /CU /EWC 1 8 1040 19 RECEPTS: CAMERA UMBRELLAS 1/2" #12 #12 #12 20/1 R isg R 20/1 1/2" #12 #12 #12 RECEPT: PRINTING STATION 20 21 SPARE — 20/1 R 20/1 1/2" #12 #12 #12 RECEPTS: BACKDROP 22 540 23 SPARE — — — — 20/1 — R 20/1 1/2" #12 #12 #12 RECEPTS: STUDIO 24 540 25 LTG: SIGN 1/2" #12 #12 #12 20/1 L 17200 R 20/1 1/2" #12 #12 #12 RECEPT: CASHWRAP 26 27 . TIMECLOCK 1/2" #12 #12 #12 20/1 N R 20/1 1/2" #12 #12 #12 RECEPTS: SELLING STATION 28 700 29 SPARE 20/1 R 20/1 1/2" #12 #12 #12 RECEPTS: SELUNG STATION 30 720 31 SPARE 20/1 R 20/1 1/2" #12 #12 #12 RECEPTS: SELUNG STATION 32 720 33 SPARE — — — — 20/1 — — 20/1 — — — — SPARE 34 _ 35 SPARE — — — — 20/1 — R 20/1 1/2" #12 #12 #12 RECEPT: SHOW WINDOW 36 360 37 RTU -1 3/4" #8 #8 #10 45/3 A R 20/1 1/2" #12 #12 #12 RECEPT: SHOW WINDOW 38 32600 39 #8 A 4260 w 50/2 1/2" #8 — #10 INST —A —HOT 40 41 #8 A w #8 42 4160 INTERRUPT RATING: 12315 13877 13012 FROM: METER CENTER DEMAND MINIMUM LOADS (IN VA ) CONNECTED FACTOR FEEDER LIGHTING 4604 1.25 5755 DEMAND MINIMUM LOADS CONNECTED FACTOR FEEDER NON— SEASONAL MOTORS 0 1.0 0 REMAINING ,, CONTINUOUS LOADS 0 1.25 0 REMAINING NON CONTINUOUS LOADS 200 1.0 200 RECEPTS TO 10 KVA 10000 1.0 10000 DEMAND LOADS 0 1.0 0 LARGEST MOTOR 0 0.25 0 RECEPTS REMAINING 6480 0.5 3240 TOTAL CONNECTED LOAD 39.2 KVA 108.9 AMPS WATER HEATING 8320 1.0 8320 SPACE HEATING 0 0.0 0 AIR CONDITIONING 9600 1.0 9600 KITCHEN EQUIP. 0 1.0 0 MIN. FEEDER /PANEL CAP. 37.1 KVA 103.1 AMPS OVERALL DEMAND FACTOR 0.95 0 PROVIDE WITH BOLT -ON BREAKERS AND ISOLATED GROUND BUS. 0 VIA TIME CLOCK #1. O VIA TIME CLOCK #2. 0 LOCKABLE BREAKER LOCKED IN "ON" POSITION. O ISOLATED GROUND CIRCUIT. 0 BREAKER SHALL BE 'HACR' TYPE. ELLoo3b 00 REVIEWED WITH NFPA70 -NEC NUV 3 0 2010 eltyof"fukwlla BUILDING DIVISION RECEIVED NOV 17 2010 PERMIT CENTER L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2M @L2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER it yy „,...� uGu 71: l 4201 West Gray Tampa, Florida Telephone: (813) Fax: (813) 287 .ii,N �. bt4 h1� , w , pq \h��i. ..° `. '`t"�'110�.ej.l • �.,y C) �s 1...r ;Z V w W. ,4 .:‹1!1K\ INNii Street : 33609 287 -2719 -5704 'G�+'1^ ? r„,J�,�,. ,�• (g' -ill r. ii'' v+t_ I 314' rd, CO ,1. \ I I THE PICTURE PEOPLE 180010TH STREET SUITE 300 PLANO, TX 75074 - N 1) REV. # ISSUE 1 DESCRIPTION DATE PERMIT 11/03/10 SHEET TITLE: SERVICE RISER, PANEL SCHEDULE, DETAILS DRAWING DATE: . 08 OCT 10 DRAWN BY DW REVIEWED BY: DW /HH PROJECT 1l 10.281 SHEET i E-401 FILE NAME: 10281 E4.dwg i ELECTRICAL SPECIFICATIONS 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, THE LATEST EDITION OF N.F.P.A., AND THE LATEST EDITIONS OF THE LOCAL CODES AND ORDINANCES, INCLUDING ALL AMENDMENTS TO THE N.E.C. EQUIPMENT, WHERE APPLICABLE, WILL BE LISTED WITH THE UNDERWRITERS LABORATORIES, INC. QUALITY AND WORKMANSHIP ESTABLISHED BY DRAWINGS AND SPECIFICATIONS ARE NOT TO BE REDUCED BY THE ABOVE MENTIONED CODES. 2. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND ACCEPTANCE OF THIS SYSTEM BY THE ENGINEER /ARCHITECT MUST BE A CONDITION OF THE SUB CONTRACT. 4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 7. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 8. CONTRACTOR TO PAY FOR ALL PERMITS, FEES INSPECTIONS AND TESTINGS. 9. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND TELEPHONE COMPANIES. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL POWER AND TELEPHONE COMPANIES PRIOR TO START OF CONSTRUCTION. 10. ALL WIRING SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. ALL CONDUCTORS SHALL BE COPPER WITH THWN /THHN INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID; ALL THOSE #8 AND LARGER TO BE STRANDED. 11. ALL UNDERGROUND RACEWAYS SHALL BE MINIMUM 3/4 ", GALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY WITH GOVERNING CODES. WHERE RIGID STEEL IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST RESISTANT BITUMASTIC PAINT, KOPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. RIGID STEEL SHALL ALSO BE USED WHEN CONDUIT IS EXPOSED TO EXTERIOR ENVIRONMENT SUCH AS EXTERIOR OF BUILDING OR WHERE IT IS EXPOSED AND SUBJECT TO DAMAGE, INSIDE OF BUILDING. 11.1 ALL UNDERGROUND SERVICE CONDUITS /RACEWAYS ENTERING BUILDING OR STRUCTURE FROM OUTSIDE TO INSIDE SHALL BE SEALED, INCLUDING SPARE CONDUITS. SEALANT SHALL BE SUITABLE FOR THIS USE. 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. ALL BOXES SHALL BE RECESSED (FLUSH) IN WALLS OR CEILINGS WHENEVER POSSIBLE. 13. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK -MAKE, QUICK -BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.C. AND LOCATION (WEATHERPROOF, EXPLOSION PROOF, ETC.). ENGRAVED LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL DISCONNECT SWITCHES, CONTACTORS AND STARTERS. 13.1. ALL FUSES FOR SAFETY SWITCHES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE. FUSES SHALL BE THOSE MANUFACTURED BY EITHER BUSSMAN OR LITTLEFUSE. THE CONTRACTOR SHALL FURNISH TO THE OWNER ONE SPARE FUSE FOR EACH SIZE AND TYPE OF FUSE INSTALLED. FUSES 600 AMPS OR LESS SHALL BE CLASS RK1, TYPICAL UNLESS OTHERWISE NOTED. FUSES OVER 600 AMPS SHALL BE CLASS L. 14. ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. CATALOG NUMBERS LISTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES BY PASS & SEYMOUR, BRYANT, OR ARROW HART WILL BE ACCEPTED. COLOR OF DEVICES AND PLATES SHALL BE DICTATED BY ARCHITECT /OWNER. A. SWITCHES: LEVITON #CSB1 -20I B. RECEPTACLES: LEVITON #BR20 -I C. COVER PLATES: SMOOTH PLASTIC NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. 15. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT BE PLACED IN PROPER WORKING ORDER. 16.1. A SEPARATE, GREEN TYPE THW COPPER GROUND CONDUCTOR SHALL BE RUN FROM GROUND LUG OF EACH GROUNDED RECEPTACLE TO AN APPROVED CONNECTION INSIDE THE ENCLOSING STEEL OUTLET BOX. DEVICE MOUNTING SCREWS SHALL NOT BE CONSIDERED AN APPROVED GROUND. 16.2. A SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT AND RACEWAY AND SECURELY BONDED IN AN APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RUN. THE GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH TABLE 250 -122 OF THE N.E.C. CONTRACTOR SHALL SIZE CONDUIT TO ACCOMMODATE ADDITIONAL CONDUCTOR. 16.3. GROUND RODS SHALL BE 5/8" DIAMETER, TEN (10) FEET LONG COPPERCLAD STEEL. OBTAIN TWENTY FIVE (25) OHMS MAXIMUM RESISTANCE AS READ WITH AN OHM METER, USING TWO REFERENCE RODS. IF TWENTY FIVE (25) OHMS CANNOT BE ACHIEVED, CONTRACTOR SHALL PROVIDE ADDITONAL RODS, UNTIL TWENTY FIVE (25) HAS BEEN OBTAINED. 17. LOAD DATA IS BASED ON INFORMATION GIVEN ENGINEER AT THE TIME OF DESIGN. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. 18. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR IS TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. 19. FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING, AND CONNECTIONS ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH MECHANICAL CONTRACTOR REGARDING SUPPLY AND INSTALLATION OF ALL REQUIRED CONTROLS. 20. THE DISCONNECT SWITCH, FUSE SIZES, CONDUIT AND WIRE SHOWN FOR ALL HVAC ARE SIZED PER THE MANUFACTURER, AND MODEL NUMBER LISTED ON THE MECHANICAL PLANS. IF THERE IS AN EQUAL MANUFACTURER, OR OTHER MANUFACTURER PROVIDED, THE MECHANICAL/ GENERAL CONTRACTOR SHALL BEAR ANY ADDITIONAL COST INCURRED IF THE ELECTRICAL IS NOT EQUAL TO SPECIFICATIONS. 21. ALL SWITCHGEAR, PANELS, STARTERS, CONTACTORS ETC., SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, THE SYSTEM DESIGN IS BASED ON SQUARE "D "; HOWEVER, COMPARABLE EQUIPMENT BY SIEMENS, G.E. AND CUTLER HAMMER ONLY WILL BE ACCEPTABLE. TANDEM AND HALF -SPACE CIRCUIT BREAKERS SHALL NOT BE USED. 21.1. TYPEWRITTEN CIRCUIT INDEX SHALL BE AFFIXED TO INSIDE SURFACE OF EACH PANELBOARD DOOR, CLEARLY INDICATING AREA AND TYPE OF LOAD SERVED BY EACH BRANCH CIRCUIT PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED WILL NOT BE ACCEPTED. 21.2. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL PANELS AND SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. 22. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RIGID STEEL ELBOWS AND RIGID STEEL SECTIONS AT SLAB PENETRATIONS WHERE SUBJECT TO POSSIBLE DAMAGE. 23. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL POWER COMPANY AT THE SITE PRIOR TO CONSTRUCTION. AT THAT TIME, THE CONTRACTOR SHALL COORDINATE ALL RELATED WORK WITH THE UTILITY COMPANY'S RESPONSIBILITIES TO MEET THE OWNER'S SCHEDULE. 24. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, RIGID GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. TYPE 'NM', 'MC', ELECTRICAL NON- METALLIC TUBING, & FLEXIBLE METAL CONDUIT MAY BE USED FOR BRANCH CIRCUITING AS ALLOWED BY THE N.E.C. & AHJ. MAXIMUM NUMBER OF 120V CIRCUITS ALLOWED IN A COMMON CONDUIT SHALL BE SIX (6). THE CONTRACTOR SHALL STRICTLY CONFORM TO THE N.E.C. REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND CONDUIT FILL. NO CONDUITS SHALL BE INSTALLED, EXPOSED ON ROOF. 24.1. CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: 208V SYSTEM 480V SYSTEM NEUTRAL - WHITE NEUTRAL - WHITE PHASE A - BLACK PHASE A - BROWN PHASE B - RED PHASE B - ORANGE PHASE C - BLUE PHASE C - YELLOW GRD.CON - GREEN GRD.CON - GREEN 24.2. WHEN MAIN ELECTRICAL SERVICE HAS A WIREWAY, E.C. SHALL TAP OFF OF ALL SERVICE ENTRANCE FEEDERS (PARALLEL CONDUCTORS) FOR TOTAL AMPACITY & BALANCING. 25. CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL CONDUIT PENETRATIONS MADE THROUGH FIRE RATED WALLS, CEILINGS, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L. ASSEMBLY STANDARDS. 26. CONTRACTOR SHALL PROVIDE SHOP DRAWING SUBMITTALS FOR LIGHT FIXTURES, SWITCHGEAR, WIRING DEVICES, EMERGENCY GENERATOR /TRANSFER EQUIPMENT, AND ALL SYSTEMS (FIRE ALARM, SECURITY, ETC) PROVIDE TWO (2) COPIES, TEN (10) DAYS PRIOR TO BID DATE FOR ENGINEER'S APPROVAL TO SUBMIT. ENGINEER'S APPROVAL OF THE PRIOR APPROVAL PACKAGE WILL BE CONSIDERED PRELIMINARY. FINAL APPROVAL WILL BE CONTINGENT UPON REVIEW OF FINAL SHOP DRAWINGS. ALL PROPOSED ALTERNATES MUST BE INDUSTRY STANDARD EQUALS TO THE ITEMS SPECIFIED AS THE BASIS OF DESIGN; HOWEVER, IF THE ITEMS ARE NOT CONSIDERED EQUAL BY THE ENGINEER, IT SHALL BE DISAPPROVED FOR FINAL SUBMITTAL. IF ELECTRICAL CONTRACTOR/ GENERAL CONTRACTOR DOES NOT SUBMIT SHOP DRAWINGS TO ELECTRICAL ENGINEER FOR ITEMS LISTED ABOVE, ELECTRICAL ENGINEER WILL NOT BE RESPONSIBLE FOR ANY, AND OR OMISSIONS OR ERRORS DUE TO SHOP DRAWINGS NOT SUBMITTED. SHOP DRAWINGS WILL ONLY BE REVIEWED TWICE AS PART OF THIS CONTRACT. ADDITIONAL SHOP DRAWING REVIEWS SHALL BE INVOICED AT $85.00 PER HOUR, BILLABLE TO THE SUB - CONTRACTOR, C.O.D. 27. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DRAWINGS AT JOB SITE WITH COLORED MARKINGS INDICATING PROGRESS OF WORK. THIS SET OF CONTRACT DRAWINGS IS TO BE SEPARATE FROM AND IN ADDITION TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF EQUIPMENT, DEVICE, CONDUIT AND WIRE IS TO MARKED WHEN INSTALLED. USE GREEN TO INDICATE INSTALLATION AS SHOWN ON DRAWINGS AND USE RED TO INDICATE FIELD CHANGES. UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, AND BECOME PROPERTY OF THE ARCHITECT. PHASE SEQUENCE ABC, TOP TO BOTTOM LEFT TO RIGHT, FRONT TO BACK 28. THE OWNER RESERVES THE RIGHT TO REVISE THE DRAWING FROM TIME TO TIME TO INDICATE CHANGES IN THE WORK. WHEN REVISED DRAWINGS AND /OR ANY REVISIONS ARE ISSUED, THE CONTRACTOR SHALL EVALUATE THE CHANGES PROMPTLY. BEFORE INSTALLATION OF ANY ITEM OR PERFORMANCE THE WORK INDICATED BY THE REVISED DRAWINGS OR REVISIONS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT /ENGINEER IN WRITING THAT THE REVISED DRAWINGS INVOLVE AN AN ADDITION OR DEDUCTION OF A SPECIFIC AMOUNT OF MONEY TO THE CONTRACT PRICE. THE CONTRACTOR SHALL NET PROCEED WITH THE REVISED WORK WITHOUT PRIOR WRITTEN APPROVAL BY THE ARCHITECT /ENGINEER OF THE COST OF THE REVISED WORK. 29. IF ELECTRICAL CONTRACTOR HAS QUESTIONS, OR IN THEIR OPINION FINDS OMISSIONS OR ERRORS ON ELECTRICAL DOCUMENTS, IT IS THEIR RESPONSIBILITY TO BRING THIS TO THE ATTENTION OF THE ELECTRICAL ENGINEER /ARCHITECT /OWNER IMMEDIATELY. IF ELECTRICAL CONTRACTOR PROCEEDS WITH ANY CHANGES TO THE CONTRACT DOCUMENTS WITHOUT WRITTEN PRIOR APPROVAL FROM THE ELECTRICAL ENGINEER /ARCHITECT /OWNER WILL NOT BE COMPENSATED. REVIEWED .FOR COMPLIANC E N NFP� NUV 3 0 2010 City of Tukwila BUILD! G DIVISI s N 6--093 b RD Nov 17 zom PERMIT CENTER 1Ali L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2M @L2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER ELECTRICAL LEGEND_ .,. • •4 THE PICTURE PEOPLE 1800 10TH STREET SUITE 300 PLANO, TX 75074 • !_is RT R MANUAL FIRE ALARM PULL STATION 48" AFF DUCT SMOKE DETECTOR REMOTE TEST /LED SWITCH RELAY MODULE MINI HORN SMOKE DETECTOR, PHOTOELECTRIC HEAT DETECTOR FLOW SWITCH TAMPER SWITCH SYSTEM BELL (75 ALARM COMBINATION HORN/STROBE 80" AFF CANDELA UON) MOUNTED AT 80 AFF OR AS SHOWN ON PLANS FIRE ALARM STROBE (75 CANDELA UON) MOUNTED AT 80" AFF OR AS SHOWN ON PLANS FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL A I---I FLUORESCENT LIGHT FIXTURE, LETTER INDICATES TYPE ",..-- --...., EG CONDUCTORS IN 1/2 CONDUIT CONCEALED IN WALL OR ABOVE CEILING WITH 2 #12, 1 #12 " CONDUIT MIN UON / CONDUIT CONCEALED BELOW FLOOR SLAB OR FINISHED GRADE WITH / 2 #12, 1 #12 EG CONDUCTORS IN 3/4" CONDUIT MIN UON _ _ _ _ CONDUIT EXPOSED ON WALL OR CEILING WITH 2 #12, 1 #12 EG CONDUCTORS IN 1/2" CONDUIT MIN UON OB RECESSED LIGHT FIXTURE, LETTER INDICATES TYPE 10 c WALL BRACKET LIGHT FIXTURE, LETTER INDICATES TYPE 0-0D POLE WITH ARM MOUNTED FIXTURE, LETTER INDICATES TYPE \% \ LIGHT FIXTURE ON EMERGENCY POWER OR WITH BATTERY PACK MM x [S1-• EXIT LIGHT (ARROW INDICATES DIRECTION, SHADING INDICATES FACE) BATTERY POWERED EMERGENCY LIGHT d v s TRACK LIGHTING PHASE, NEUTRAL, ISOLATED GROUND CONDUCTORS FLEXIBLE CONDUIT NOT TO EXCEED 6 FEET IN LENGTH �TV� TELEVISION SYSTEM EMPTY CONDUIT WITH PULL WIRE - / LOW VOLTAGE WIRING \ CONDUIT SEAL -OFF FITTING FOR COOLER/FREEZER CIRCUITS M C1 5 $ -S _9_5 © ®4 '0' ' ` FACP $° SINGLE POLE SWITCH, LOWER CASE LETTER INDICATES LIGHT CONTROLLED, MOUNT 48" AFF UON S2 DOUBLE POLE SWITCH, MOUNT 48" AFF UON S3 THREE -WAY SWITCH, MOUNT 48" AFF UON S4 FOUR -WAY SWITCH, MOUNT 48" AFF UON D6 DIMMER SWITCH, WATTS AS NOTED, (6= 600W, 10= 1000W) MOUNT 48" AFF UON SP SINGLE POLE SWITCH WITH PILOT LIGHT, MOUNT 48" AFF UON SF FAN CONTROLLER, MOUNT 48" AFF UON S MR MOTOR RATED SWITCH SM MOMENTARY CONTACT SWITCH, MOUNT 48" AFF UON SK KEY OPERATED SINGLE POLE SWITCH, MOUNT 48" AFF UON S° OCCUPANCY SENSOR SWITCH, MOUNT 48" AFF UON ® OCCUPANCY SENSOR SWITCH, CEILING MOUNT SINGLE RECEPTACLE, 125V, 20A MOUNT 18" AFF UON DUPLEX RECEPTACLE, MOUNT 18" AFF UON mc DUPLEX RECEPTACLE, FLUSH CEILING MOUNT • DUPLEX RECEPTACLE, MOUNT ABOVE COUNTER HEIGHT UON 4 QUADRAPLEX RECEPTACLE, MOUNT 18" AFF UON O QUADRAPLEX RECEPTACLE, MOUNT ABOVE COUNTER HEIGHT UON DUPLEX RECEPTACLE, HORIZONTAL MOUNT Cc 1/2 SWITCHED DUPLEX RECEPTACLE, MOUNT 18" AFF UON 30A 10, 250V. RECEPTACLE, AMPS AS NOTED, MOUNT 18" AFF UON 1-0 SPECIAL RECEPTACLE AS NOTED Q FLOOR MOUNTED DUPLEX RECEPTACLE + t PLUGMOLD (SIZE AND LENGTH AS NOTED) / / J' ` CONDUIT STUB III DRIVEN GROUND ROD CONDUIT UP -0 CONDUIT - -• DOWN ` • JUNCTION BOX FOR PADDLE FAN, FLUSH MOUNTED PER THE N.E.C. I ■ ,.D DISCONNECT SWITCH, NEMA /SIZE /POLE /FUSES (NEMA 1 UON) (250V UON) ► MAGNETIC MOTOR STARTER `® COMBINATION MAGNETIC MOTOR STARTER /DISCONNECT SWITCH T DRY TYPE TRANSFORMER - CONTACTOR (AS NOTED) Tc TIME CLOCK Pc PHOTOCELL `D• MOTOR PERMANENTLY CONNECTED WITH FLEXIBLE CONDUIT FAAP L 1 ACC -CU AFF AFG AFI A /H -AHU ATS BFG C CLG CT DN EX -(E) EC E /F -EF EG EWC EWH GEC GFI HID ABBREVIATIONS CONDENSING UNIT HP HORSE POWER ABOVE FINISH FLOOR IG ISOLATED GROUND ABOVE FINISH GRADE JB JUNCTION BOX ARC. FAULT INTERRUPTER LSIG LONG, SHORT, INSTANTANEOUS GROUND FAULT SETTING AIR HANDLING UNIT (N) NEW AUTOMATIC TRANSFER NEUT NEUTRAL SWITCH BELOW FINISHED. GRADE NF NON FUSED CONDUIT NIC NOT IN CONTRACT CEILING MOUNTED NL NIGHT LIGHT CURRENT TRANSFORMER NP NAME PLATE DOWN NTS NOT TO SCALE EXISTING PNL PANEL ELECTRICAL CONTRACTOR (R) RELOCATED EXHAUST FAN RTU ROOF TOP UNIT EQUIPMENT GROUND TL TWIST LOCK ELECTRIC WATER COOLER TTB TELEPHONE TERMINAL BOARD ELECTRIC WATER HEATER TYP TYPICAL GROUNDING ELECTRODE UON UNLESS OTHERWISE NOTED CONDUCTOR GROUND FAULT INTERRUPTER WP WEATHERPROOF HIGH INTENSITY DISCHARGE rd VAr ELECTRIC DUCT HEATER THERMOSTAT. PROVIDE SINGLE GANG BOX WITH 1/2" C STUBBED O INTO CEILING SPACE, MOUNT 60" AFF UON (COORDINATE WITH MECHANICAL DRAWINGS PRIOR TO ROUGH -IN) Qs SPEAKER O4 T.V. CAMERA DATA OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT WITH FO PULL WIRE AND INSULATING BUSHING STUBBED INTO CEILING SPACE. MOUNT BOX 18" AFF UON � 00 ) REFER TO LIKE NUMBERED NOTES /EQUIPMENT DESIGNATIONS TELEVISION OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT FEI WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO CEILING SPACE. MOUNT BOX 18" AFF UON TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" V CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO CEILING SPACE. MOUNT BOX 18" AFF UON PS TELEPHONE WALL OUTLET, PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO • CEILING SPACE. MOUNT BOX 48" AFF UON ( "PS ":INDICATES PAY STATION) ® FLOOR MOUNTED TELEPHONE OUTLET TELEPHONE BACKBOARD J JUNCTION BOX (FLUSH MOUNT IN FINISHED AREAS UON) • DEVICE AS NOTED PB PUSHBUTTON, MOUNT 48" AFF UON DOOR CHIME WITH TRANSFORMER ■ LIGHTING OR POWER PANELBOARD ® 277/480V, PANELBOARD PP TELEPHONE /DATA -POWER POLE STUB -UP, PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT WITH ED PULL WIRE AND INSULATING BUSHING STUBBED INTO CEILING SPACE. MOUNT BOX 18" AFF UON ® (SIZE AS NOTED) COMBINATION TELEPHONE /DATA WALL OUTLET, PROVIDE SINGLE GANG V BOX WITH 3/4" CONDUIT WITH PULL WIRE AND INSULATING BUSHING STUBBED INTO CEILING SPACE. MOUNT BOX 18" AFF UON LEGEND NOTES: 1. MOUNTING HEIGHTS SHOWN ARE MAXIMUM /MINIMUM HANDICAPPED ACCESSIBILITY STANDARDS - THEY SHALL NOT BE ALTERED WITHOUT WRITTEN AUTHORIZATION 2. ALL MOUNTING HEIGHTS ARE TO CENTERLINE UON. 3. ALL SYMBOLS MAY NOT BE USED ISSUE1DESCRIPTION DATE REVIEWED .FOR COMPLIANC E N NFP� NUV 3 0 2010 City of Tukwila BUILD! G DIVISI s N 6--093 b RD Nov 17 zom PERMIT CENTER 1Ali L2M 811 Cromwell Park Drive, Suite 113 Cromwell Business Park at BWI Glen Burnie, Maryland 21061 L2M @L2M.com Phone 410.863.1302 Fax 410.863.1308 CONSULTANT: Harold Hart. P.E. CONSULTING ENGINEER 4201 West Gray Street : Tampa, Florida 33609 Telephone: (813) 287 -2719 Fax: (813) 287 -5704 81.4.4, C7 w ^ , •r S .,. • •4 THE PICTURE PEOPLE 1800 10TH STREET SUITE 300 PLANO, TX 75074 - N /) REV, # ISSUE1DESCRIPTION DATE PERMIT 1 1/03/1 0 SHEET 11111: LEGEND AND SPECIFICATIONS DRAWING DATE: 08 OCT 10 DRAWN BY: DW REVIEWED BY DW /HH PROJECT 1 10.281 SHEET 1 E-501 FILE NAME: 10281 E5.dwg