Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0950 - SHOWALTER MIDDLE SCHOOL
SHOWALTER MIDDLE SCHOOL 4626 S 144 ST EL1O-0950 Parcel No.: Address: Tenant Name: Cityef Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Li ne: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1523049164 4628 S 144 ST TUKW SHOWALTER MIDDLE SCHOOL ELECTRICAL PERMIT Permit Number: EL10 -0950 Issue Date: 12/03/2010 Permit Expires On: 06/01/2011 Owner: Name: Address: Contact Person: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST , TUKWILA WA 98168 BRIAN SKINNER 5005 3 AV S , SEATTLE WA 98134 Contractor: Name: MCKINSTRY ELECTRIC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINE *982KG Phone: 206 - 832 -8403 Phone: 206 832 -8513 Expiration Date: 05/08/2012 DESCRIPTION OF WORK: ADDING (2) DISCONNECTS 30A EACH, (1) CIRCUIT FOR T8 LIGHTING FIXTURE, (1) CIRCUIT EACH FOR CONDENSING UNIT & EVAPORATOR UNIT. TOTAL OF (2) DISCONNECTS & (3) CIRCUITS 30A. Value of Electrical Work: NRES: $3,700.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: $196.88 National Electrical Code Edition: 2008 �f l��lJw •DsN,L Date: ' _ 0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature`fG� Print Nam Date: /2/5/ro This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0950 Printed: 12 -03 -2010 • • PERMIT CONDITIONS Permit No. EL10 -0950 * *ELECTRICAL ** 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL10 -0950 Printed: 12 -03 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto. //www. ci. tukwila. wa. us Electrical Permit `No. -.7 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** °SITE LOCATION Site Address: 462S S• 111.TN ST Tenant Name: Tvk -w,/a sr> King Co Assessor's Tax No.: Suite Number: New Tenant: Property Owners Name: Tv'w' l5 S T Floor: ❑ Yes [No Mailing Address: 4640 S • 14-1711 sr. Tv le- I WA 98/68 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: P3L? - sfr..—/,J ,JE2 S-o0 S 312-0 ,4 a S. SEATI LC E -Mail Address: Sr ► a f) SIB @ M cfG %n S-Y y Day Telephone: 206 - 83Z- w.* 9eij' City State Zip Fax Number: z-°6 - 83 Z - 8G a ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: fL/Msfi/Li Co, SO 5" 3rd »v& s, 611 -1A-n/ S - FNNe�/L S 7t-LE City E -Mail Address: i ria/>s McKJ1/is A//1- 9e1Sy State Zip Day Telephone: T-€)6 — toS Z - S yp Fax Number: ?�° 6 S S Z— O C 0 3 Contractor Registration Number: #C14//1)-4418 E Z X6-7 Expiration Date: C.iS /o8 Zn 12 Valuation of Project (contractor's bid price): $ '/ Scope of Work (please provide detailed information): Hvdr_ (2) ii- c.av,v s 30,4 eArd , i_ e4/ -i4' /x /t/ee eA/ e,&/ ,/ - �G�/i rv� ay./ / .W9Drai ex,-1; f ef 11-) Will service be altered? ❑ Yes [(]i‹o e9c/din1 %.14 -, Type of Use: T e of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light free Z•el" ❑ Service Change ❑ Fire Alarm H:\Applications\rorms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 Adding more than 50 amps? ❑ Yes I lii ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: /4t1161-a /�bf')dc/ C/;/ ,e_ Print Name: /-44Ql 1 CA'A^— Date: /1— /S— / Day Telephone: 1-06- S'Z - Ot-io Mailing Address: 5-‘905— `' 4v6 S, Se�7'�f fe Ii/ A. %$ / 3 City Date Application Accepted: Date Application Expires: t 1 -7 _ I I State Zip Staff Initials: "I li H:\Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 . • r-' ' City of Tukwila 2 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 1523049164 Permit Number: EL10 -0950 Address: 4628 S 144 ST TUKW Status: PENDING Suite No: Applied Date: 11/17 /2010 Applicant: SHOWALTER MIDDLE SCHOOL Issue Date: Receipt No.: R10 -02337 Initials: User ID: WER 1655 Payment Amount: $196.88 Payment Date: 11/17/2010 03:50 PM Balance: $0.00 Payee: MCKINSTRY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11182 196.88 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 157.50 000.345.832.00.00 39.38 Total: $196.88 doc: Receipt -06 Printed: 11 -17 -2010 3 INSPECTION RECORD 611V0?50 Retain a copy with permit INSPECTION NO. PERMIT NO.� CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: �� Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: a.-m. p.m. Requester: Phone No: BFI Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 K Inspector: P /� Date: © ��Il� 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2' INSPECTION NO. INSPECTION RECORD Retain a copy with permit (to- c1ccD PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: ..0- 1,44, Type of Inspection: Address: -I (QZ? 5./L/ Date Called: Special Instructions: _ Date Wanted: /�� ca,„;,,,. Requester: ' Phone No: Approved per applicable codes. Corrections required prior to approval. C' COMMENTS: 7i4( r- ) *ad RieS ean4q r M ate eilkArciC TO kiA4e A Prifirriorj f10 ? (100, Inspector: ;t76.6wei Date: r I (Jl] 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: 1 �V �, ^ Ty e of Inspection: 7 Address: ileii 5 /91/ 5r- Date Called: Special Instructions: Date Wanted: / �� �'a m. rid Requester: row\h< Phone No: 25c V3 5-- ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: t`U OR ;Z vJ!D +4) / oiSc_R2A)Auucr dare5 DiScANI fzei Po<1401,1e_ 51-11.g gra)q, Inspector: Date: a-24 to I n REINSPECTION FEE REQUIRE[). Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ••�r� ti. • PER �, • COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0950 DATE: 11 -17 -10 PROJECT NAME: SHOWALTER MIDDLE SCHOOL SITE ADDRESS: 4628 S 144 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 3!' C 1k - V Building Division Public Works Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-18-10 Complete Incomplete Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions Ix/ DUE DATE: 12 -16 -10 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pfter Friendly Page • Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company MCKINSTRY ELECTRIC UBI No. 2067623311 Status Po Box 24567 License No. License Type Seattle Effective Date WA Expiration Date 98124 Suspend Date King Specialty 1 Limited Liability Company Specialty 2 FACILITY ELECTRICAL SRVCS LLC 602198837 Active MCKINE *982KG Electrical Contractor 5/7/2002 5/8/2012 General Unused Master Electrician INFORMATION License ZEHNER *962CJ Name ZEHNER, RICK A Status Active Business Owner Information Name Role Effective Date Expiration Date BLACK, STEPHEN Partner /Member 05/07/2002 Bond Amount ALLEN, DEAN C Partner /Member 05/07/2002 929495258 MOORE, DOUGLAS J. Partner /Member 05/07/2002 ELECTRICAL CITATION TEPLICKY, J. WILLIAM Partner /Member 05/07/2002 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY CO 929495258 05/04/2010 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.0004/05/2010 $150.00 1 TRAVELERS CAS & SURETY CO 103737415 04/29/2002 Until Cancelled 05/04/2010 $4,000.0005/07/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ESWAT00252 5/11/2009 19.28.010 RCW ELECTRICAL CITATION Satisfied $250.00 ESWAT00251 5/11/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $150.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 12/03/2010 LIGHTING 0-. 0—. Q SK $os Sr tbs $L.v 0 9 9 FLUORESCENT FIXTURE, DRAWN TO SCALE ON PLANS — LETTER IN FIXTURE INDICATES SWITCH LEG CONTROL FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE FIXTURE CEILING MOUNTED FIXTURE WALL MOUNTED FIXTURE RECESSED WALL MOUNTED BATTERY PACK LIGHTING FIXTURE, WALL WASHER TRACK UGHT FIXTURE SUPPLIED FROM EMERGENCY CIRCUIT EXIT SIGN — DIRECTIONAL ARROWS AS INDICATED, SHADED SIDES ILLUMINATED LIGHTING STANDARD — FIXTURE(S), POLE & BASE LIGHT FIXTURE TYPE — SEE FIXTURE SCHEDULE SWITCH — SINGLE POLE SUBSCRIPTS a,b, etc., DENOTES CIRCUIT CONTROLLED 3 WAY SWITCH 4 WAY SWITCH SWITCH — KEY OPERATED SWITCH — OCCUPANCY SENSOR SWITCH — WITH PILOT LIGHT SWITCH — TIMER DIMMER DIMMER W /OCCUPANCY SENSOR MOMENTARY CONTACT LOW VOLTAGE SWITCH SWITCHOANK RELAY — NEC CLASS II LOW VOLTAGE TRANSFORMER OCCUPANCY SENSOR SWITCH — PHOTO CELL CIRCUITS 4\\I RACEWAY CONCEALED IN CEILING OR WALL HASH MARKS INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE NOTED. THREE WIRES IF NO HASH MARK SHOWN. LONG HASH MARK DENOTES NEUTRAL -r— INDICATES GROUND WIRE. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW CONDUCTORS) RACEWAY BELOW SLAB OR UNDERGROUND EXPOSED CONDUIT RUN ON SURFACE OF WALL OR CEILING RACEWAY UP RACEWAY DOWN RACEWAY STUB —OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION ® JUNCTION BOX 8 PULL BOX Q GROUNDING ROD CONTROL FUSED DISCONNECT SWITCH (FUSE RATING INDICATED) D DISCONNECT SWITCH ® MOTOR STARTER — MAGNETIC Mb MANUAL STARTER Eh COMBINATION MOTOR STARTER DISCONNECT SWITCH ENCLOSED CIRCUIT BREAKER cD THERMOSTAT I TIME CLOCK CONTACTOR ai RELAY — CONTROL TYPE 9 PHOTOCELL CONTROL PUSH BUTTON CONTROL STATION H AUTO DOOR PUSHPLATE 8 ELECTRICAL RISER IocxI FUSED SWITCH CIRCUIT BREAKER DRAWOUT CIRCUIT BREAKER CIRCUIT BREAKER — GROUND FAULT PROTECTION CABLE TO BUS CONNECTION FUSE OR CURRENT LIMITER GROUND CONNECTION IDENTIFICATION SYMBOL FOR FEEDER SIZES TRANSFORMER WATT —HOUR METER AMMETER VOLTMETER 12' TRANSFER SWITCH Q ENGINE — GENERATOR 1 XXXX > AVAILABLE SHORT CIRCUIT CURRENT EQUIPMENT PANEL — 208 VOLT SYSTEM PANEL — 480 VOLT SYSTEM EQUIPMENT CONNECTION MOTOR CONNECTION SINGLE PHASE MOTOR CONNECTION 3 PHASE TRANSFORMER TRANSIENT VOLTAGE SURGE SUPPRESSOR GENERAL INFORMATION SYMBOLS X X X x X KEY NOTE REVISION SYMBOL POINT OF CONNECTION POINT OF DEMOLmON LIGHT UNE INDICATES EXISTING DEVICES REMOVE EXISTING ELECTRICAL EQUIPMENT NEC CODE REQUIRED CLEAR WORKING SPACE EQUIPMENT DESIGNATION ELECTRICAL INFORMATION EQUIPMENT DISCONNECT AD —AMP DISCONNECT AF —AMP FUSES DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN PLAN NUMBER SHEET NUMBER WHERE, PLAN SHOWN REVISION NUMBER — DENOTES NUMBER AND DATE WHEN REVISION OR ISSUE OCCURED REVISION CLOUD — DENOTES AREA OF CHANGE DETAIL REFERENCE OUTLINE WITH NUMBER AND SHEET LOCATION ABBREVIATIONS ACH ABOVE COUNTER HEIGHT AFF ABOVE FINISHED FLOOR AG ABOVE GRADE A, AMP ATR ATS AWG CB CKT CTB DED DTI Dw AMPERE ALL THREAD ROD AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE CIRCUIT BREAKER CIRCUIT COMMUNICATIONS TERMINAL BOARD DEDICATED DRY TYPE TRANSFORMER DISHWASHER EC ELECTRICAL CONTRACTOR EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR Fl FILM ILLUMINATOR G, GND GROUND GD GARBAGE DISPOSAL GROUND FAULT EQI GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HP HORSEPOWER J —BOX JUNCTION BOX MC MECHANICAL CONTRACTOR MCC MOTOR CONTROL CENTER MW N NEC NIC 0 PNL PSE R RO RECEPT REF SCH SCI SPECS SW SWBD TELE MICROWAVE NEUTRAL NATIONAL ELECTRICAL CODE NOT IN CONTRACT PHASE PANEL PUGET SOUND ENERGY RACEWAY RACEWAY ONLY RECEPTACLE REFRIGERATOR SCHEDULE SEATTLE CITY LIGHT SPECIFICATIONS SWITCH SWITCHBOARD TELEPHONE TYP TYPICAL v VOLT VP W WC WP XFMR VANDALPROOF WATT WARMING CABINET WEATHERPROOF TRANSFORMER GENERAL NOTES 1. COMPLY WITH NATIONAL ELECTRICAL CODE LATEST ADOPTED EDITION AND WAC 296 -46B. 2. SYMBOLS ME BALED ON A STANDARD PACKAGE PER CATEGORY. NOT ALL SYMBOLS MAY APPEAR ON DRAWINGS. 3. THE LOCATIONS OF ELECTRICAL DEVICES OR UGHTING FIXTURES INDICATED ON MECHANICAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS. 4. COORDINATE WORK WITH THAT OF ALL CONTRACTORS AND /OR OTHER TRADES DOING WORK ON THE PROJECT. EXAMINE ALL DRAWINGS AND SPECIFICATIONS OF OTHER TRADES FOR CONSTRUCTION DETAILS AND COORDINATION. 5. OBTAIN AND REVIEW ALL SUBMITTALS AND SHOP DRAWINGS OF EQUIPMENT WITH ELECTRICAL CONNECTIONS. OBTAIN AND REVIEW ALL SUBMITTALS AND SHOP DRAWINGS OF EQUIPMENT WITH ELECTRICAL CONNECTIONS FURNISHED UNDER OTHER DNISIONS OF THE SPECIFICTION AND BY THE OWNER. PROVIDE ALL WIRING IN ACCORDANCE WITH SPECIFIC EQUIPMENT REQUIREMENTS. IMMEDIATELY ADVISE THE ENGINEER OF ANY CHANGES WHICH MAY EFFECT THE CONTRACT. 6. THE DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY AND WHAT IS CALLED FOR (OR SHOWN) IN EITHER IS REQUIRED TO BE PROVIDED AS IF CALLED FOR IN BOTH. AS -BUILT REQUIREMENTS vS AND PANEL SCHEDULES REFLECTING CHANGES DEVIATING FROM CONSTRUCTION DOCUMENTS. 2. AS —BUILT DRAWIINGS SHALL BE RETURNED TO MCKINSTRY ENGINEERING WHEN COMPLETED. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR: C ''itechanicat Q Electrical arAIUMbhla ia' as POinO City of Tukwila BUILDING DIVISION LOCATION 1 SITE MAP FILE COPY Permit No. Sikl.0-423.4r0 F "n review approval is subject to SITOIS and omissions. 1 fr©val of construction documents does not authorize t, violation of any adopted code or ordinance. Receipt c. approved Field Copy and conditions is acknowledged: By Date: City Of"W WI& BUILDING DIVISION PROJECT LOCATION DRAWING INDEX TED FOR COMPLIANCE WITH NFPA 70 - NEC NUV 3 0 2010 . uN\ City of Tukwila G DIVISION SHEET NO. SHEET TITLE t BUILDIr E0.0 COVER SHEET E3.1 PARTIAL POWER PLANS E6.0 ONE —LINE DIAGRAM E7.0 PANEL SCHEDULES — BEFORE AND AFTER PROJECT: le Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800.8696223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503- 331 -0234 www.mckinstry.com SHOWALTER MIDDLE SCHOOL WALK -IN FREEZER 4628 SOUTH 144TH STREET TUKWILA, WASHINGTON 98168 REGISTRATION: REVISIONS: 10 -28 -10 100% CONSTRUCTION DOCUMENTS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING R. CLARK D. CARLSON D. STEINERT P10739 10 -21 -2010 AS SHOWN COVER SHEET SHEET NUMBER: RECEIVED NOV 1 7 2010 PERMIT CENTER EL 10-0950 E0.0 0 0 CONDENSING UNIT 8 MCA, 480V -3P 30AD, 15AF 0 0 0 v� 0 M2- 7,9,11 (SECT -1) 0 • 10 0 2 tl 0 0 0 0 PARTIAL ROOF POWER PLAN SCALE: 1 /r = 1' -0" C H O R E3121 1 UGHT DOOR GENERAL NOTES: 1. ELECTRICAL CONTRACTOR SHALL MAKE ALL PENETRATIONS THROUGH THE WALK —IN FREEZER AS NECESSARY FOR ELECTRICAL CONNECTIONS. COORDINATE WITH EQUIPMENT VENDOR LOCATIONS AND SEALING REQUIREMENTS OF INSTALLED CONDUITS. KEY NOTES: 0 DISCONNECT SHALL BE IN NEMA 3R RATED ENCLOSURE. O PROVIDE 1 —LAMP (T8), WET LOCATION SUITABLE, 120V, 4 FT FLOURESCENT STRIP FIXTURE, UTHONIA DM /DMW SERIES OR EQUAL FIXTURE TO BE CONTROLLED VIA MANUFACTURER PROVIDED UGHT SWITCH. t, 3 DISCONNECT SHALL BE IN NEMA 3R RATED ENCLOSURE. 0 ELECTRICAL CONTRACTOR SHALL INSTALL CONDUITS INSIDE THE CONDENSING UNIT CURB. LLE:CJ. LA-143 (E) PANEL LA C (E) PANEL PA P PM MTD AAB PAA- 1,3 SWITCH SEAL- PM -2,4 FOOD STOR. � EXISTING FLOOR DRAIN EVAPORATOR 18 MCA, 208V- A 30AD, 20AF FOOD SERV. OFF. L.A141_ CORR 13 HEAT TRACE CONNECTION 0 vAEC -./ 3OII....FR A144 (E) PANEL K KITCHEN [_1391 PARTIAL POWER FLOOR PLAN Glir SCALE: Y" = 1' -0" (E) PANEL M2 ELlo- OsO REVIEWED FOR - CONFPA COMPLIANCE NECK NW 3 0 2010 City of Tukwila BUILDING DIVISI ' N KEY PLAN NOT TO SCALE PROJECT: "fe Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503 - 331 -0234 www.mckinstry.com SHOWALTER MIDDLE SCHOOL WALK -IN FREEZER 4628 SOUTH 144TH STREET TUKWILA, WASHINGTON 98168 REGISTRATION: REVISIONS: 10 -28 -10 100% CONSTRUCTION DOCUMENTS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING R. CLARK D. CARLSON D. STEINERT P10739 10 -21 -2010 AS SHOWN PARTAI L POWER PLANS SHEET NUMBER: RECEIVED NOV 17 2010 PERMIT CENTER E3.1 TO UTILITYS II 3/4 "C- 4 #8, 1#8G � II PANEL TRANSFORMER TA 9kVA XEMR 480V- 208/120V PM 3 /4"C— CB 3 #12, 1 #12G NEC SERVICE POINT UTILITY TRANSFORMER 14 PANEL LA CONDUCTOR (Sc CONDUIT SCHEDULES MARK CONDUIT NUMBER &SIZE Cu CONDUCTORS PER CONDUIT INSULATION QUANTITY SIZE ®1 5 — 4 ' 4 #500 MCM THWN '® 3" 4 #350 MCM THWN O. 2" 3 #2/0 THWN ® 2" 4 #3/0 THWN ®5 1 -1 /2" 4 #1/0 THWN ® 3/4" 4 #8 THWN Q 2-2" 4 #3/0 THWN ® 1-1/2" 4 # 1 THWN 9® 3/4" 3 #6 THWN 10 1" 4 #4 THWN 11 1 -1 /2" 3 #1 THWN 12 3/4" 3 #1 0 THWN 13 1 -1 /2" 3 #3/0 THWN 14 2" 3 #4/0 THWN 15 2 — 3" 4 #350 MCM THWN 16 2" 4 #4/0 THWN 200A ENCLOSED C.B. PANEL PANEL PANEL PA PA PA SEC 1 SEC 2 SEC 3 PANEL PB EXISTING PANEL WITH LOAD MODIFICATIONS PANEL C1 PANEL PC SEC 1 PANEL PC SEC 2 TRANSFORMER TK 400A ENCLOSED C.B. PANEL K SEC 1 PANEL K SEC 2 TRANSFCRMER TE--\\1/4 TRANSFORMER TS PANEL LE PANEL PE UTILITY DEMAND HISTORY DATE kW 91/5/20091 313.64 1011412009 3213.25 1//1412009 250.49 12/1 6/2009' 252.55 1/16/2010: 259,93 2/20/2010 268.18 3/20/2010 282.07 4/1712010 273.31 5/18/2010 321.21 6/17/2010 388.53 7/20/2010 327.37 TRANSFORMER TF PANEL PD SEC 1 PANEL PD SEC 2 PANEL c2 PANEL LF PANEL PF 100A SPACE LOAD SUMMARY MAIN SWBD 1600A, 480/277V, 3PH, 4W PANEL MAX RECORDED DEMAND 12 MONTH READING M 467.33 A ASSUMED POWER FACTOR (pt? 0.89 89% 436.56 kVA 525,09 A SEC 3 TOTAL DEMAND ON EXISTING SERVICE (PER NEC 220.88) = x 125% 545.69 kVA 656.36 A LOAD CHANGES 5.19 6.28 10.47 kVA 6.24 A 6.35 A 12.59 A PANEL M2 PANEL LA TOTAL CALCULATED LOADS ADDED = SUMMA'T1ON: EXISTING DEMAND ON EXISTING SERVICE TOTAL CALCULATED LOAD CHANGES 545.69 kVA 10.47 kVA 656.36 A 12.59 A TOTAL LOAD ON SERVICE UPON COMPLETION = 556.16 kVA 668.95 A w PANEL S 400A ENCLOSED C.B. W /AUX. DRY CONTACTS 200AD 200AF 1 400A BUS 200AD 200AF EXISTING PANEL WITH LOAD MODIFICATIONS ELEVATOR 1600AF 16QOAT W /GFI 400AF 300AT 1 200AF 175AT 1 100AF 100AT g 400AF 1 400AT I 60AF 40AT J. DISTRIBUTION PANEL 'DP' 480Y/277V 60A ENCLOSED C.B. TRANSFORMER TG- PANEL M2 SEC 1 PANEL M2 SEC 2 1[-77 PANEL LG PANEL PG SEC 1 PANEL PG SEC 2 PANEL C3 TRANSFORMER TM� PANEL PANEL PANEL M M M SEC 1 SEC 2 SEC 3 PANEL MP SEC 1 LlO- 09'50 200AF 200AT 1 1 600AF 600AT 400A SPACE 200A SPACE 200A SPACE 1 ONE -LINE DIAGRAM SCALE: NTS MAIN SWITCHBOARD, 1600A BUS 480Y/277V, 30, 4W REVIEWED .FOR WP WITH COMPLIANCE - NEC NUV 3 0 2010 BUILDcwlla ING DIVISION PROJECT: e Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1- 800 - 669.6223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 www.mckinatty.com SHOWALTER MIDDLE SCHOOL WALK -IN FREEZER 4628 SOUTH 144TH STREET TUKWILA, WASHINGTON 98168 REGISTRATION: REVISIONS: 10 -28 -10 100% CONSTRUCTION DOCUMENTS NO. DATE DESCRIPTION McKINSTRY DIVISION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: ENGINEERING R. CLARK D. CARLSON D. STEINERT P10739 10 -21 -2010 AS SHOWN SHEET TITLE: ONE —LINE DIAGRAM SHEET NUMBER; RECEIVED NOV 17 2010 PERMIT CENTER E6.0 x PANEL SCHEDULE McKinstry NAME: M2 ( ECT-1).(EXISTING) 1 3 .5 7 i 19 13 15 17- 19 21 23- 25 27 29 31 33 35 37 39 41 0 , 0.40 1 , 0 VOLTAGE; 480Y/ 277V 3 ph. 4 wire 1 1 LOCATION: ROOM# 22&A BUS 225A 39P MAIN LUGS ONLY .:II kAfC TYPE ' DESCRIPTION ' LOAD kVA fmip *1 TRIP .RATIRG1 TRP RATIRG1 • LOAD kVA 'TYPE ' DESCRIPTION HVAC AHU-I301 16.66 I-1VAC AHU-1301 40/ 3 20! 3 • 1 S SPARE CB ' NO Nop um 2 - 4 - gig 290 1111 illial 3 3 3 20/ 3 20/ 3 3 - 4 - 6 LTS LIGHTING ., 213 - - - - sis 1.90 -6 3 ,....,_______ 3 3 -6 - 8 - 10 - 12 - 14 -16 -18 _ 20 -22 24 26 - 28 -30 _ .....,...---- .-.............„.....,„,.....,..,..........-....- - - Si 9111M 3 --........ 3 3.80 SPARE CB 3 20! EQUIP WLK-IN FRZR COND.UNIT ------ 7,56 HVAC MUA-01 ariest mtr (!:? 125% - lie :20/ .3 8 1102 -- 7.56 HVAC MUA-01-ntr@ 1111 125%) - SPARE CB - - al 3 - 3 201 1 20/ 1 20/ 3 , ------------ Is SS I -12 . 14 201 1 .3 1 ' 201 1 HVAC MUA-B01 6,05 EQUIP EF-13 - . 2,00 2 - 14 16 144 ________ 1 20/ 3 Iiii space only 3 3 -.a - - - 16 - 18 - 20 -- 20/ 1 Sri Si; al Ea la ow am irk - 1 - 18 - 20 22 -24 - 26 - 28 - 30 3 ------ ------- . space only 1 20/ 1 3 3 1 SPARE CB space only .run........MINM41*.a. • HVAC CU-B01 54.02 IMMO I 90/ .3 3 30/ 3 - - - - :ii - - - - 11.63 EQUIP BOI LER CONTROL PANEL - - - - - ' _ 31 on 90/ 3 30! 3 space only 11,63 . m....,' ' - _piece o _31 space only space only space only • • - 3 - 28 - 30 SPARE CB EQUIP COMP-A01 2.07 1 20/ 3 3013 3 MEI 20/ 3 NMI MEIN 201 1 20, 1 • i I 1 6.05 EQUIP PMP-A02 20/ 3 , .• . 2 - - - 3 3 1 s - spar.L__e ord _______ .... ... ....___ ,_. 695 111 30/ 3 .......--_......- EQUIP 13141P-A01 6,05 EQUIP R/E-B01 - - la ma 6.05 32 - 34 - 36 _________ ...... _ - MN MUM I 20/ 1 20/ 1 . _.... ... 3 3 30/ 3 SPARE CB SURGE PROTECTIVE DEVICE SPARE CB - ma Sili - - - 38 - 40 SPARE CB SPARE CB - SPARE CB 1111111111 20/ 1 201 1 3 30/ 3 SPARE CB • Wr • - 42 • LOAD TYPE CONN, kVA) NEC CALCULATED FACTOR NEC CALC. LOAD (kVAI 3 6.05 PHASE CONN, (kVA) NEC FACTO NEC LOA 1 (WA) NEC AMPS PANEL NOTES: LTS REC REC HVAC KIT IS, LTS EQUIP MISC 79..7 41.0 125% '100% 100% 100% 100% 100% 100% 100% 79.7 41.0 Ili NEW CONDENSING UNIT CONNECTED TO EXISTING CIRCUIT BREAKE:R "BEFORE" PANEL CONDITIONS A: B: C: 42.84 40.84 40.84 100% 100% 100% 42.84 40.84 40.64 164.6 147,4 147,4 NEC TOTAL: 124.52 "BEFORE PANEL CONDITIONS 124.62 49.8 " CIRCUIT BREAKER CODE G -•". GFCI H = HID RATED S = SHUNT TRIP ID en SWITCHING DUTY FED FIROM: SPARE CB SPARE CB DOWNSTREAM LOAD INFORMATION TOTAL 120.7 100% 120,7 FEEDER LENGTH: 1REV: DATE: FEED THRU LUG X DOUBLE LUGS M2(SE9772) FEEDER: FEED THRU LUGS PANEL SCHEDULE Mc Kinstry NAME: M2 ( ECT-1) (EXISTING) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 36 39 41 0 0 0 0 VOLTAGE: 480Y/ 277V 3 ph. 4 wire LOCATION: ROOM O 226A BUS 225A 3P MAIN LUGS ONLY 30 kAIC TYPE ' DESCRIPTION ' fmip *1 LOAD kVA ' " TRIP RATIRG1 TRIP RATI7G1 • LOAD kVA ' TYPE ' DEsCRIPTIoN I-1VAC AHU-1301 20/3 0 3 16.68 1 S 40/ 3 20/ 3 NO Nop um SPARE CB - gig 290 - 2 4 3 3 - 4 - 6 LTS LIGHTING ., 213 - 3 3 1.90 LTS LIGH'T1NG 3 3 3 Ea al Erg iirw ja is BE is ja is is aril ja, -6 - 8 - 10 - 12 - 14 -16 -18 _ 20 -22 24 26 - 28 -30 _ .....,...---- .-.............„.....,„,.....,..,..........-....- - , 20! 3 3 --........ 3 3.80 MAU-A02 -..............„.....-___-_ EQUIP WLK-IN FRZR COND.UNIT ------ V] 8 10 5.19 - 8 2 :20/ .3 201.3 3 7.56 HVAC MUA-01-ntr@ 201 1 125%) - SPARE CB - ss all 171 Si al a 3 3 3 201 1 20/ 1 , ------------ Is SS I -12 . 14 201 1 .3 3 ' 201 1 - - 1 - space only HVAC MUA-8O1 2,00 2 144 ________ 1 20/ 3 201 3 space only 895 EQUIP E5-13 -.a - - - 16 - 18 - 20 space only 20/ 1 space only - 1 3 3 _____Ipewonl 1, space only . space only 1 20/ 1 SPARE CB SPARE CB space only .run........MINM41*.a. • - - 3 3 - - - - :ii - - - - ii ma is Si 11 ika IS - 24 -- 26 HVAC CU-1301 space only ' _ 5492 on 90/ 3 30! 3 space only 11,63 EQUIP BOILER CONTROL PANEL m....,' ' : _piece o space only space only space only 3 3 - 28 - 30 SPARE CB _ - 1 space only space only -. 28 - 30 - 32 - 34 - 36 spac onhr . ___-- 20/ 3 - 24 1 .• . 2 - - - 3 3 1 s SPARE CB spar.L__e ord spEelo.nt 2 3 space only EQUIP COMP-A01 2.07 201 3 30/ 3 space only .. . 6.05 EQUIP PMP-A02 - : L L. . . s ace ork_._11L‘,____ space only . . space only 3 3 30/ 3 ------------ SURGE PROTECTIVE DEVICE - •i -A-- - - only _____................-____ EQUP space only . s 3 _ . . 695 3 30/ 3 3 201 3 ,ihm M Wr - 40 _ ... PIVIP-A01 . . . 3 _______.--_-----.........-_. EQUIP R/E-B01 3 6.05 - ------------------------ - - 32 3 42 LOAD TYPE CONN. 1 NEC CALCULATED NEC i CALC, FACTOR 1LOAD (kVA) , NEC 1NEC LOAD FACTOR(kVA) 3 3 '3 NEC AMPS PANEL NOTES: - 3,1 ....,--------------.... "BEFORE PANEL CONDITIONS - es 100% i 3E5 100% 1.65 100% : 1.85 - ,36 NEC TOTAL 6.94. 6.94 SPARE CB SPARE CB • CIRCUIT BREAKER CODE G .= GFCI H = HID RATED S m! SHUNT TRIP 'D •c!, .SWITCHING DUTY FED FROM: NEC CALCULATED N 20/ 1 201 1 3.1 100% 3.1 - CB SPARE CB LTS • REV: FEED THRU LUGS 125% A - III DATE: - 40 SPARE CB NEC "TOTAL 8.94 ' , , 6.94 8 8.3 ' CIRCUIT BREAKER CODE 20/ 1 201 1 DOWNSTREAM LOAD INFORMATION SPARE CB - • • - 42 • LOAD 'TYPE CONN . (kVA). NEC CALCULATED FACTOR 125% 180% 160% 160% 100% 100% 100% 100% NEC CALC. LOAD. (kyR , 781 46.2 DATET* - PHASE A: 8: C: CONN. (kVA) 44,57 42.67 42.57 NEC FACTOF 100% 100% 100% NEC LOAD (WA) 44.57 42.57 42.57 NEC AMPS 160,8 153.6 153.6 _ a PANEL NOTES: (11 NEW CONDENSING UNIT CONNECTED TO EXISTING CIRCUIT BREAKER LTS REC. n 0 HVAC KIT S. LTS EQUIP MISC 79.7 45.2 NEC TOTAL; 129,71 129.71 165.0 *CIRCUIT BREAKER CODE 0 l' GFCI H = HID RATED S = SHUNTTRIP D am SWITCHING DUTY FED FROM; DOWNSTREAM LOAD INFORMATION 'TOTAL 125.9 100% 125.9 FEEDER LENGTH: .FEEDER. _ .. ._,, ' REV: .___ . DATE: FEED IHRULUG„:,X DOUBLE LUGS M2,i.SECT.2L..............,..m.:619kye) PANEL SCHEDULE McKinstry NAME: M2 (tECT-2) (EXISTING) 3- 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39.. 41 0 , , 1 0 1 0 . „ . VOLTAGE; 460Y/ 277V 3 •ph. 4 wire . , LOCATION: ROOM# 225A BUS 225A 3P MAIN LUGS ONLY 30 kAIC TYPE 1 DESCRIPTION! 1 LOAD kVA 1 fmip *1 RATINIG1 TRIP RA21111G/ 1 * LOAD kVA TIPE DESCRIPTION SPARE CB 193 20/3 0 3 20/ 3 1 1 S SPARE CB - NO Nop um - 2 - 4 6 20/ 1 290 3 3 3 3 - 4 - 6 LTS LIGHTING ., 213 - 201 1 20! 1 1.90 LTS LIGH'T1NG 3 3 3 20/ 1 1.14 _________ 3 EQUIP PN1P-A08 1,14 , 20! 3 20/ 3 20/ 3 7 3.80 MAU-A02 - El SS - - 8 10 - - 8 2 - 10 3 3 201 1 3 9 3 SPARE CB - - ss all 171 Si al a : , 3 3 201 1 20/ 1 , - - Is SS I -12 . 14 201 1 EQUIP WH-A01 2,00 ' 201 1 - - 1 1 space only s LICe on 2,00 2 20/ 1 1 ________ space only - - az Si 1.0 1 16 - 18 - 20 space only 20/ 1 space only - 1 SPARE CB space only _____Ipewonl 1, space only . space only 1 20/ 1 SPARE CB SPARE CB space only space only . - - - 18 s space only - - - - :ii - - - - ii ma is Si 11 ika IS - 24 -- 26 - 22 - 24 - 26 space only ' _ 201 1 on _____Ippo_nly__ 1 .....____ space only space only . space onk_____ m....,' ' : _piece o space only space only space only space only - 28 - 30 SPARE CB 1 space only space only -. 28 - 30 - 32 - 34 - 36 spac onhr . 20! 1 20/ 3 - 24 1 .• . 2 PNL PAA [1] - - ._ space only space only 1 s SPARE CB spar.L__e ord spEelo.nt 2 3 space only space only ...„ _ , s SPARE GB Va..PeprtY . 2 space only .. . space only 3 : : L L. . . s ace ork_._11L‘,____ space only . . space only 2001 3 301 3 30/ 3 EQUP 1VSS SURGE PROTECTIVE DEVICE - •i -A-- - 38 only . s space only . s 3 - 30/3 1 ,ihm M Wr - 40 _spac.e space only . . . 3 3 DEVICE . 3 ------------------------ - 3 42 LOAD TYPE CONN. 1 NEC CALCULATED NEC i CALC, FACTOR 1LOAD (kVA) , NEC 1NEC LOAD FACTOR(kVA) 'CONN. PHASEAVA) .NEC [NEC LOAD FACTOR(kVA) NEC AMPS PANEL NOTES: LTS REC REC HVAC KIT S, LIS EQUIP MISC 3,1 125% 100% 100% 3 , i00% 100% . 100% 100% 3.1 100% "BEFORE PANEL CONDITIONS A: 137. C: 3.65 1,65+ . 1,65 100% i 3E5 100% 1.65 100% : 1.85 13.2 5.9 5.9 NEC TOTAL 6.94. 6.94 8.3 • CIRCUIT BREAKER CODE G .= GFCI H = HID RATED S m! SHUNT TRIP 'D •c!, .SWITCHING DUTY FED FROM: NEC CALCULATED N DOWNSTREAM LOAD INFORMATION TOTAL 3.1 100% 3.1 FEEDER LENGTH: LTS • REV: FEED THRU LUGS 125% A FEEDER: -BEFORE" PANEL CONDITIONS DATE: DOUBLE LUGS 13.2 BEFORE CONDITIONS AFTER CONDITIONS PANEL SCHEDULE , Mckinstry NAME: M2 (.§ECT-2) (EXISTING) N 1 . 0 0 0 0 N V 0 2 VOLTAGE: 480Y/ 277V 3 ph, 4 wire . I 22&A BUS 225A 3P MAIN LUGS ONLY 33kAIC TYPE ' DESCRIPTION , : k LOAD T "1 R TRIP T TRIP L • !kVA 1 LOAD TYPE ' DESCRLIPTION SPARE CB 2 193 20/ 1 20/ 3 1 20/ 3 1 1 S LTS LIGHTING SPARE CB 1.45 201 1 20/ 1 290 3 3 3. ' ' - 4 - 6 LTS LIGHTING ., 213 201 1 20! 1 1.90 LTS LIGH'T1NG LTS LIGH11NG 3 5 3 20/ 1 1.14 _________ 3 - EQUIP PNIP-A013 1 1,14 2 LTS LIGHTING 20/ 3 7 20! 3 ! ! 1 180 M MAU-A02 - - SPARE CB - - 8 2 - 10 -------- 3 3.14 201 1 3 9 3 SPARE CB - - ss all 171 Si al a - 12 - 14 - 16 - 16 - 20 - 22 SPARE CB 201 1 20/ 1 3 1 3H SPARE CB I 201 1 20/ 2 - - LTS LIGHTING EXT. - - 1 1 EQUIP WH-A01 ' ' 2 2,00 2 20/ 1 1 ________ space only Aen2a 1 SPARE CB 1 201 1 20/ 1 space only - 1 SPARE CB 16 s . space only 1 20/ 1 SPARE CB SPARE CB space only . - - - 18 s - - II - 24 -- 26 SPARE CB ' _ 201 1 on _____Ippo_nly__ 1 .....____ space only SPARE GB m....,' ' _piece o space only space only _spastat1 2 s - 28 - 30 SPARE CB 1 space only - - 20! 1 20/ 3 - 24 1 .• . 2 PNL PAA [1] - - ail- 1 s SPARE CB spar.L__e ord spEelo.nt 2 3 2.39 , s SPARE GB Va..PeprtY . 2 201 1 3 : L L. . . s ace ork_._11L‘,____ Apassizalt : : 3 2001 3 301 3 EQUP 1VSS - -A-- 66.10, . s space only . s 1 - 30/3 1 ' s ......................._.. seal only 3 . . . 3 --....-.._..,......................_ DEVICE . 3 LOAD TYPE 3 r NEC CALC. LOAD (WA) PHASE .. . NEC 1NEC LOAD FACTOR(kVA) NEC AMPS .. 40 3 LTS REC REC HVAC K IT S, LTG' EQUIP MISC _lppsIptjy___ . 125% 1 100% 100% 100% 65% 100% 100% 100% 39.4 5.3 261.8 Ill PROVIDE 20A-3P CIRCUIT BREAKER 3 ! ! ; - 103% 103% 103% -------------------- - - NEC TOTAL. 238.63 - 42 3 LOAD C CONN, N NEC CALCULATED N NEC CALC. C FED FROM: CONN. NEC NEC LOADINEC PANEL NOTES: P LTS • 3.1 1 • 1 125% A 3.1 - -BEFORE" PANEL CONDITIONS A: 3,65 100% : : 3.65 1 13.2 NEC "TOTAL 8.94 ' , , 6.94 8 8.3 ' CIRCUIT BREAKER CODE G = GFCI 1••I = HID RATED FED FROM D DOWNSTREAM LOAD INFORMATION TOTAL 3 3.1 1 100% 3 3.1 FEEDER LENGTH: R * - D REV: F FEED THRU LUGS DATET* D DOUBLELUG 5 PANEL SCHEDULE !NAME: LA (EXISTING) ILOCATION: 1 ROOM# 1 TYPE DESCRIPTION 1LTS LIGHTING RM A143 1LTS LIGHTING ILI'S LIGHTING 1LTS LIGHTING ILLTS LIGHTING LTS LIGHTING SPARE CB SPARE CB SPARE CB SPARE CB SPARE CB 1 LOAD TRIP kVA .1 RATIRG" 1 1.83 201 1 1.45 20/ 1 2.13 20/ 1 2.85 201 1 ' 4.00 20/ 1 3.14 201 1 201 1 201 1 20/ 1 20/ 1 20/ '1 201 1 20/ 1 201 1 20/ 1 20/ 1 20/ 1 201 1 200/ 3 3 SPARE CB SPARE CB SPARE CB SPARE CB SPARE CB SPARE CB SPARE CB PNL TRANSFORMER TA 68.72 66.10 67.01 LOAD TYPE LTS REC REC 1HVAC K IT S. LT$ EQUIP MISC 1TOTAL. CONN. NEC CALCULATED (WA) FACTOR NEC CALC. LOAD (kVA) 3 3 - 5 - 7 - - 11 - 13 - 15 - 17 - 19 - 21 - 23 - 25 - 27 - 29 - 31 - 33 - 35 - 37 - 39 - 41 - • ci 2 4 6 - 8 - 10 - 12 - 14 - 16 - 18 - 20 - 22 - 24 - 26 - 28 - 30 - 32 - 34 - 36 - 38 - 40 - 42 VOLTAGE: MY/ 27• N' 3 ph. McKinstry 4 wire 4aad51, sus 400A 3IP MAIN LUGS ONLY 361 kAIC TRIP LOAD RATINIG1 " kVA _ TYPE 1 20/ 1 DESCRIPTION 232 LTS LIGHTING 20/ 1 290 LTS LIGHTING 20/ 1 1.90 LTS LIGHTING 20/ 1 1,14 LTS LIGHTING EXT. 20/ i SPARE CB _ SPARE GB 20/ 1 1.88 LTS LIGHTING EXT. 20/ 1 20/ 2 5.58 LTS LIGHTING EXT. 2 201 1 20/ 1 20/1 SPARE CB SPARE CB SPARE CB • space only space only space only spaceonly space onlY. 30/3 space onI COUP TVSS 3 3 .....101111•4•40. am mg ....■•••••■•••■•••.001 ■■•••• IM 0.wal PANEL NOTES: 31.6 201.8 125% 100% 100% 100% 65% 100% 100% 100% 39.4 201.8 "BEFORE" PANEL CONDITIONS FED FROM: 233.4 103% 241.2 FEEDER LENGTH: FEEDER; .CONN. PHASE(kVA) 79. B1 77. CI is. NEC TOTAL1 233. 4 CIRCUIT BREAKER C G GEC! 5 SHUNT TRIP NEC FACTOF NEC LOAD (kVA) NEC AMPS 103% 103% 103% 81.81 14 24 79.85 97 70,67 35 ODE •-* HID RATED D •SWITCHING DUTY 241.23 295.2 266.1 287,1 290.2 DOWNSTREAM LOAD INFORMATION REV: FEED THRU LUGS DATE: DOUBLE LUGS PANEL SCHEDULE McKinstry NAME: LA(EX ISTING) 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39- 41 0 - 0 1 0 - 2 , VOLTAGE: 480Y/ 277V 3 ph. 4 Wire LOCATION: • ROOM# • 1 400A BUS 400A 3P MAIN LUGS ONLY 3,61)AIC TYPE ' DESCRIPTION ' LOAD 1 kVA i :" TRIP RATIFIG" IP RATIRG` i LOAD kVA ' TYPE ' DESCRPTION LTS LIGHTING RN! A143 193 20/ 1 201 1 2.72 LTS LIGHTING LTS LIGHTING 1.45 201 1 20/ 1 290 LTS LIGHTING - -- li - 4 - 6 LTS LIGHTING ., 213 201 1 20! 1 1.90 LTS LIGH'T1NG LTS LIGH11NG 2.85 20/ 1 20/ 1 1.14 LTS LIGHTING EXT. - dm - 8 LTS LIGHTING 4.001 20/ 1 20/ 1 SPARE CB - iria - 10 LTS LIGHTING 3.14 201 1 20/ 1 SPARE CB - - ss all 171 Si al a - 12 - 14 - 16 - 16 - 20 - 22 SPARE CB 201 1 20/ 1 1,88 LTS LIGHTING EXT. SPARE CB I 201 1 20/ 2 5,58 LTS LIGHTING EXT. - SPARE CB 1 20/ 1 2 ________ - _______ SPARE CB 1 201 1 20/ 1 SPARE CB - - SPARE CB 20/ 1 20/ 1 SPARE CB SPARE CB 2O 1 201 1 SPARE CB - - II - 24 -- 26 SPARE CB 201 1 space only SPARE GB 20/ 1 space only space only - - - 28 - 30 SPARE CB 201 1 SPARE CB 20! 1 20/ 3 2.89 PNL PAA [1] - - ail- - 32 - 34 - 36 - 38 SPARE CB 20/ 1 3 2.39 SPARE GB 201 1 3 PNL TRANSFORMER TA 68.72 2001 3 301 3 EQUP 1VSS - 66.10, 3 3 - 17,- a - 40 ""w - 42 ......................._.. 67.01, 3 3 --....-.._..,......................_ LOAD TYPE NEC CALCULATED FACTOR I r NEC CALC. LOAD (WA) PHASE CONN, (kVA) NEC 1NEC LOAD FACTOR(kVA) NEC AMPS PANEL NOTES: LTS REC REC HVAC K IT S, LTG' EQUIP MISC 31.5 5.3 201,8 125% 1 100% 100% 100% 65% 100% 100% 100% 39.4 5.3 261.8 Ill PROVIDE 20A-3P CIRCUIT BREAKER A: B: C: 82.03 79.63 76.97 103% 103% 103% 84.74 82.26 79.51 305.8 296,8 2136.0 NEC TOTAL. 238.63 246.51 296.5 * CIRCUIT BREAKER CODE G = GFCI H '% HID RATED S = SHUNT TRIP D Ei SWITCHING DUTY FED FROM: DOWNSTREAM LOAD INFORMATION TOTAL 238.6 103% II 246.5 FEEDER LENGTH:__ FEEDER _"REV: ..DATE: FEEDTHR DOUBLE LUGS _ ,...... PANEL SCHEDULE McKinstry , NAME: PAA (NEW) 0 0 0 VOLTAGE: •208Y/ 120V 3 ph, 4 wire t Y , 1 • 1 LOCATION: ROOM# +- -4- 60A1BUS 35A 3P MAIN BREAK& 10 kAIC LOAD TRIP 35A TRIP LOAD TYPE • DESCRIPTION ' kVA ' "" RAT1RG" RATOG" " kVA " TYPE ' DESCRIPTION EQUIP FREEZER EVAPORATOR 3.38 20/ 2 1 - - 2 20/ 1 'G 1.20 EQUIP FREEZER HEAT TRACE 2 3 - - 4 201 1 0.70 EQUIP FREEZER DOOR, LTS 6 - - 6 4 LOAD CONN. NEC CALCULATE NEC CALC, iCONN. NEC 1NEC LOAD NEC TYPE , (kVA) FACTOR LOAD (kVA) PANEL NOTES; PHASE(kVA) FACTO (kVA) . . . AMPS LTS 125% A.:;1. 2.89 100% 2.89 241 REC 100% 6-CIRCUIT LOAD CENTER 8:11 2.39 100% 2,39 19.9 REC 100% Q I 100% HVAC 100% NEC TOTAL' 6.28 1 5.28 14.7 KIT 65% * CIRCUIT BREAKER CODE S, LTS 100% G = GFPE H = HO RATED EQUIP 5.3 100% 5.3 = SHUNT TRIP D = SWITCHING DUTY MISC 100t j FED FROM: DOWNSTREAM LOAD INFORMATION TOTAL 5.3 100% 5,3 FEEDER LENGT!..1: . ,. REV; _..., . _.. ., ._ , FEED THRU LUBB , _ .,,_ ,,,,.,, . 6. FEEDER: 'A.---: DOUBLE E.666- REVIEWED FOR COMPLIANCE WITH NFPA 70 • NEC NUV 3 0 2010 CItofTukWHa BUILDING DIVISI N ELIO-ft.-041S PROJECT: ire Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-8223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 umw.mckinstry.com SHOWALTER MIDDLE SCHOOL WALK-IN FREEZER 4628 SOUTH 144TH STREET TUKWILA, WASHINGTON 98168 REGISTRATION: REVISIONS: 10-28-10 100% CONSTRUCTION DOCUMENTS NO. DATE DESCRIPTION McKINSTRY DMSION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING R. CLARK D. CARLSON D. STEINERT P10739 10-21-2010 AS SHOWN PANEL SCHEDULES BEFORE AND AFTER SHEET NUMBER: RECEIVED NOV 1 7 2010 PERMIT CENTER E7.° REVIEWED FOR COMPLIANCE WITH NFPA 70 • NEC NUV 3 0 2010 CItofTukWHa BUILDING DIVISI N ELIO-ft.-041S PROJECT: ire Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98124 1-800-669-8223 PORTLAND: 12021 NE AIRPORT WAY SUITE G PORTLAND, OR 97220 503-331-0234 umw.mckinstry.com SHOWALTER MIDDLE SCHOOL WALK-IN FREEZER 4628 SOUTH 144TH STREET TUKWILA, WASHINGTON 98168 REGISTRATION: REVISIONS: 10-28-10 100% CONSTRUCTION DOCUMENTS NO. DATE DESCRIPTION McKINSTRY DMSION: DESIGNED BY: DRAWN BY: CHECKED BY: JOB NUMBER: DATE: SCALE: SHEET TITLE: ENGINEERING R. CLARK D. CARLSON D. STEINERT P10739 10-21-2010 AS SHOWN PANEL SCHEDULES BEFORE AND AFTER SHEET NUMBER: RECEIVED NOV 1 7 2010 PERMIT CENTER E7.°