HomeMy WebLinkAboutPermit EL10-0960 - TARGETTARGET 301 STRANDER BL EL1 0-0960 Cityef Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Tenant Name: TARGET ELECTRICAL PERMIT Permit Number: EL10 -0960 Issue Date: 05/03/2011 Permit Expires On: 10/30/2011 Owner: Name: TARGET CORPORATION T 0627 Address: C/O PROPERTY TAX/TPN 0950 , PO BOX 9456 55440 Contact Person: Name: DAVID CONTRERAS Phone: 971 - 998 -1451 Address: 601 SW 2 AV - SUITE 1200 , PORTLAND OR 97204 Contractor: Name: KEN BOBKO ELECTRIC CO INC Address: PO BOX 7009 , TACOMA WA 98406 Contractor License No: KENBOEC066BA Phone: 253 - 756 -0944 Expiration Date: 01/01/2012 DESCRIPTION OF WORK: UPDATE POWER TO WALK -IN COOLER BOXES, UPDATE ONE -LINE DIAGRAM, ADD NEW OVERHEAD LIGHTING, UPDATE POWER PLAN TO STORE. Value of Electrical Work: NRES: $228,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $3,554.25 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe • oes not presume to construction or the performan - • f work. I a of this permit. Signature: Print Name: authority to violate or cancel the provisions of any other state or local laws regulating orized to sign and obtain this electrical permit and agree to the conditions on the back gni Date: 5 -3-11 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -0960 Printed: 05 -03 -2011 • • PERMIT CONDITIONS Permit No. EL10 -0960 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Arty change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-0960 Printed: 05 -03 -2011 CITY OF TUKAA Community Development Depaftment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. 6)-10- O q (00 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION ( King Co Assessor's Tax No.: 2� .2- S 1 J� cif_ U cy Site Address: �' 1(���vl �GI l t� Suite Number: Floor: Tenant Name: WA ne4-- -7---(-) 2.,'":T �New Tenant: ❑ Yes g.. No Property Owners Name: [G2410-1—C477 r Mailing Address: % 0■06:' A/r—d)1 f A /1) PJ y1I�l e t M s City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: r 2027 E -Mail Address:4,U ikJ t CA/1 �� e h : M70 T on City State Zip �L° ra5 14WIt HKy12 •GU•tt Fax Number:(4I) 21 8/ `Z2 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2- 1 doc7, ,-ry- Scope of Work (a ease provide detailed information): ((4 Cel50 Jl isles AIAMIRMERFABIMPIMMONF Will service be altered? Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light HAApplications\Porns- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bb Page 1 of 2 741 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY 0 ; P + RJURY BY T . WS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 AL CONTRACTOR: Signature. i-1� � �l 111: Al -C-Ce---X-4 S r Print Name: Jet S Rri km 7 .c1 (e..pflireray S Day Tel phon Mailing Address: 6O/ j ze_J -vyo S4-e. /20091 P City Date: )( /11/1 De- /'72) -- State Zip Date Application Accepted: I' _ 19— I 0 Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL10 -0960 Status: APPROVED Applied Date: 11/19/2010 Issue Date: Receipt No.: R11 -00868 Payment Amount: $2,752.05 Initials: WER Payment Date: 05/03/2011 10:38 AM User ID: 1655 Balance: $0.00 Payee: KEN BOBKO ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 25902 2,752.05 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 2,752.05 Total: $2,752.05 doc: Receiot -06 Printed: 05 -03 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL10 -0960 Status: PENDING Applied Date: 11/19/2010 Issue Date: Receipt No.: R10 -02363 Initials: User ID: Payee: WER 1655 Payment Amount: $2.95 Payment Date: 11/19/2010 03:18 PM Balance: $3,193.25 TARGET TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1298004 2.95 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 2.95 Total: $2.95 doc: Receipt -06 Printed: 11 -19 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL10 -0960 Status: PENDING Applied Date: 11/19/2010 Issue Date: Receipt No.: R10 -02365 Initials: User ID: WER 1655 Payment Amount: $.20 Payment Date: 11/19/2010 03:24 PM Balance: $3,193.05 Payee: TARGET TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1298004 .20 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 .20 Total: $.20 doc: Receipt -06 Printed: 11 -19 -2010 • 1 J�.`Nt�A wy City of Tukwila ., � , ►�� 2 De P artment o f Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049005 Address: 301 STRANDER BL TUKW Suite No: Applicant: TARGET RECEIPT Permit Number: EL10 -0960 Status: PENDING Applied Date: 11/19/2010 Issue Date: Receipt No.: R10 -02362 Initials: User ID: WER 1655 Payment Amount: $799.05 Payment Date: 11/19/2010 03:17 PM Balance: $3,196.20 Payee: TARGET TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1298004 799.05 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 799.05 Total: $799.05 doc: Receipt -06 Printed: 11 -19 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION Na PERMIT NO. (uO-o'fo CITY OF TUKWILA BUILDING DIVISION 6300- Southcenter Blvd., #100, Tukwila. WA 98188 t (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: /� rr° Type of Inspection: �7 'co Address: Date Called: Special Instructions: ' Date Wanted:. 2 7� a.m. p.m Requester: Phone No Approved per applicable codes. Corrections required prior to approval. COMMENTS:' ku ( -IAA r! ( Date: OY/3o Ii REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ,-,- INSPECTION RECORD 0, c�0 d Retain a copy with permit INSPECTION NOr. PERMIT NO. CITY�OF TUKWILA BUILDING DIVISION 6300 .Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: 2/00 Address Date Called: Special Instructions: Date Wanted:. C .'7/7 a.m. �'`% Requester: ll Phone No: Approved per applicable codes. Corrections required prior to approval. F COMMENTS: taP:Hoer 1J ( CoQct»r5 , ?A&, aktay.6 4001a--1) rr Q ritivni u)IZ/ eA 1 .4-� DTI °JAI - rrnal�di S it ea►" Date: a/zi n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO: CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p. (206) 431-36 Permit Inspection Request Line (206) 431 -2451 6,10-a%o Project: Type of Inspection: /0 °, Address: 30 t 5-1 Date Called: Special Instructions: Date Wanted: . 7 2Z . ' . ar P.m'. Requester: Phone No: gApproved per applicable codes. El Corrections required prior to approval.. COMMENTS: 42A. Comitfioti5 Nrvb6 CL'I L1n�C� avetel RoNicia GDiPc.E -cE Inspector: &*)41 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO... CITY OF TUKWILA BUILDING DIVISION 6300 Permit Inspection Request #100, iine (06) 431-2451 188 (206) 431 -36 Project: 4er Type of Inspection: 0 D Address: Date Called: Special Instructions: Date Wanted: g 9 r! a.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: r7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: 'IAp� ' w A Type of Inspection: 7003 Address: 3Dr 51-71. rXg, Date Called: '. Special Instructions: Date Wanted:. Ca,{rry„ p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4 UJM&i CiJ 1,\Atit4/1-1-16/i Inspector. ,,e 1 ` -J6\ Date: ®boo n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPE TION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 le— (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: ......,,r Ae4 Cr- Type of Inspection: 1400 Address: 301 (S 06c Date Called: -o Special Instructions: • Date Wanted: a.m: Requester: Phone No: Approved per applicable codes. DCorrections required prior to approval. COMMENTS: / c)etlitc2Q) ePtUOnialsb r -O g07 66iPtti( O.K. OkfrJ5 - ii,..,a 1 - - e...,..c-e5 , . Inspector: Date: D-1 1 S (' I n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy withpermit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 �l.lD -0760 Project: � ��. Type of Inspection: Address: of 5 /e\ alied: Date Called' Special Instructions: Date Wanted: 7 d3 a.rt„ :•.m. ' r Requester: Phone No: ElApproved per applicable codes. I Corrections required prior to approval. COMMENTS: dr° (iccl (Lolls -6-D -- r) a n 1. %4 AJb. L.064( av-r- INpAP Ohl 6R-Fill(Eks, bot_hz\s tAle5n.inr k' .H!SS 1Aif1 t4tQ . Lr cwflec Th our mcP5 1 &M cfl cM!, c4 pre, Inspector: 41rii31-AlAifik\ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: OZ 3ie► t ..,1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 rz., (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 6140-litb0 Project: _,.•( �. Type of Inspection: 7 I 00 j Address: �1 �� r' Date Called: Special Instructions: Date Wanted: !a r a a.m. Requester: Phone No: ElApproved per applicable codes. a Corrections required prior to approval. COMMENTS: tf1 i)&cp.6 C 49vtl KO' Inspector: Date: r7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: INSPECTION RECORD- Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1 9- (206) 431-3670 Inspection Request Line (206) 431 -2451 Project: �,,, -1 me.(4 e- Type of Inspection: -, 7OO.?- Address: 30( 5rIa Date Called: Special Instructions: Date Wanted: Z(o am. : m. u ster: Req e Phone No: ❑ Approved per applicable codes. COMMENTS: Inspector: fR Corrections required prior to approval., cn,uawb vt-JE 6riVAitik, n REINSPECTION FEE REQUIRED. Prior to next inspection: fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 2 INSPECTION RECORD a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKW ILA BUILDING "DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspe ion Request Line (206) 431 -2451 Q---- Project . I �(,r Type of Inspection: tau- - 6;.t.C. rat\ T-iii -r5 Fri kie-0411u44), Address: Date Called: t1 u.n - 4tti ettrA i Special Instructions: Date Wanted: s14 a:m: Requester: / 1r if .C. zami Phone No: Door EiApproved per applicable codes. I Corrections required prior to approval. COMMENTS: 'r - 6;.t.C. rat\ T-iii -r5 Fri kie-0411u44), ezef e of\ .E To (ov -° B+ Nk, 44Da -nom R(ozki Folk t1 u.n - 4tti ettrA i - zootatiqsxnup 1:119 LIdC so Coodi Ay' t-2. 1r if .C. zami /4 —446 s Door Inspector: Date: 057-4/// REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be ._ paid at 6300 Southcenter Blv :'Suite 100. Call to schedule reinspection.: 'INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION �- (206) 431 -367 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project: /jr� r Type of Inspection: as I Address: "� -5a1 �� D. Date Called: ` Special Instructions: Date Wanted: S 1 / a.r P.m. Requester: Phone No: ljApproved per applicable codes. a Corrections required prior to approval. COMMENTS: INDC-f\f- "cot\GoAIN,t? / �' / ;4 Date: .5' oin n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection., Inspector: • UMW COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0960 PROJECT NAME: TARGET SITE ADDRESS: 301 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # DATE: 11 -19 -10 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: CC1 4„"10 Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-23-10 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 -21 -10 Approved n Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 04 -01 -2011 • City of Tukwila s Department of Community Development DAVID CONTRERAS 601 SW 2 AV - SUITE 1200 PORTLAND OR 97204 RE: Permit Application No. EL10 -0960 301 STRANDER BL TUKW Dear Permit Applicant: A Jim Haggerton, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 11/19/2010, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and /or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 05/18/2011. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. EL10 -0960 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 SKANSKA Subcontract Agreement THIS SUBCONTRACT (the "S ubcontract ") is in ade as o f this 1 Ith day of April, 2 01 1 ( "Effective Date'') by and between the Contractor and Subcontractor as identified below. Capitalized terns used in this document entitled Subcontract Agreement and not defined herein shall have the meanings assigned to them in Exhibit E. PIiOJECI' NAnIE: T -0627 TARGET TUKWII:A MR REMODEL PROJECI'.NUMBER: 4210054 -250 PROJECT ADDRESS: 301 STRANDER BLVD. TUKWILA, WA 98188 SUBCONTRACT No.: 11 VENDOR No.: 1 COST CODE REFERENCE: 16050000 CONTRACTOR: . Skanska USA Building Inc. SUBCONTRACTOR: Ken Bobko Electric Company Inc. IioatE OFFICE ADDRESS: 221 Yale Ave N. Suite 400 Seattle, WA 98109 1 ADDRESS: 4315 N 29th St. Tncoma,'WA, 98407 CONTACT: TRAVIS CARTER CONTACT: KEN RORKO TELEPHONE: 206.726.8000 TELEPI IONE: 253.756.0944 FACSIMILE: 206.328.9235 FACSIMILE: CoNrRACrOR's LICENSE NUMBER (IP REQUIRED): SKANSIJ8985R I' SUBCONTRACTOR'S LICENSE NUMBER (IF REQUIRED): KENBOEC066BA WHEREAS, Contractor has entered into a contract with Target Corporation (the "Owner") dated as of the 7th day of April, 2011 (the "Owner Contract ") to perform the construction and related work and services at the project commonly referred to as Target Southcenter (the "Project"): OWNER: TARGET CORPORATION A RCI I ITECT: Mulvanny G2 Architecture ADDRESS: 1000 NICROLLET MALL MINNEAPOLIS, MN. 55403 ADDRESS: 601 SW 2 "a Ave, Suite 1200 Portland, OR 97204 TELEPIIONE: FACSInm.E: WHEREAS, Subcontractor desires to perform, and Contractor has agreed to enter into this Subcontract with Subcontractor for the perfomtance of, a portion of the work required to complete the Project. NOW THEREFORE, for a nd i n c onsidcration o f t he covenants a nd agreements of t he pa rtics c ontained herein, Contractor a nd Subcontractor agree as follows: Subcontractor agrees to perform and complete the work required by this Subcontract, which generally consists of the Provide and Install all Electrical Work (the "Work "). 2. As full consideration for complete performance of the Work, and except for increases or decreases by Change Order as provided for i n E xhibit E , Subcontractor s hall be paid t he I ump s um of One 11 undred N inety Two Thousand Seventy T wo Dollars ($192,072.00) (the "Subcontract Amount "). 3. Subcontractor Q is ® is not (Mark the appropriate box with an .. "X') required to provide performance and payment bonds securing t he p crfornntncc of t he W ork a nd t he pa yment of S ub- subcontractors. S ubcontractor 0,, is ® is 0 of (Mark the appropriate box with an "X") required to enroll in Contractor's Subguard performance insurance program. Page 1 of 2 Subcontract Agreement (06/2006 cd. Rev. 0) Contractors or Tradespeople Peter Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company KEN BOBKO ELECTRIC CO INC 2537560944 Po Box 7009 Tacoma WA 984060009 Pierce Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601481263 Active KENBOEC066BA Electrical Contractor 1/1/1994 1/1/2012 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status KENBOEC182DN KEN BOBKO ELECTRIC CO Electrical Contractor General Unused 3/15/1982 12/31/1994 Archived Master Electrician INFORMATION License BOBKOK'962C4 Name BOBKO, KEN Status Active Business Owner Information Name Role Effective Date Expiration Date BOBKO, KEN Violation Amount 01/01/1980 2/3/2007 BOBKO, TAMI ELECTRICAL CITATION 01/01/1980 $250.00 BOBKO, KEN Agent 01/01/1980 ELECTRICAL CITATION Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 WESTERN SURETY CO 60939377 01/01/1998 Until Cancelled $4,000.00 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ECOPK01396 2/3/2007 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 ECOPK01399 2/3/2007 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 05/03/2011 BUILDING CODE INFO SITE ZONING C -P FIRE ZONE OR DISTRICT TUKWILA FIRE DEPARTMENT SEISMIC DESIGN CATEGORY DESIGN CATEGORY "D" BUILDING OCCUPANCY CLASSIFICATION M BUILDING CONSTRUCTION TYPE 2--N (EXISTING - UNCHANGED) BUILDING ALLOWABLE FLOOR AREA ALLOWED: UNLIMITED (FULLY SPRINKLERED) ACTUAL BUILDING AREA: 113,588 SF AFFECTED AREA OF WORK: 10,436 SF BUILDING ALLOWABLE HEIGHT 55' -0" MAX BUILDING CODE 2009 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMMENDMENTS ACCESSIBILITY CODE 2009 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMMENDMENTS 2003 ICC /ANSI A117.1 MECHANICAL CODE 2009 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMMENDMENTS PLUMBING CODE 2009 UNIFORM PLUMBING CODE W/ WASHINGTON AMMENDMENTS FIRE / LIFE SAFETY CODE 2009 INTERNATIONAL FIRE CODE W/ WASHINGTON AMMENDMENTS ELECTRICAL CODE 2008 NATIONAL ELECTRICAL CODE W/ WASHINGTON AMMENDMENTS ENERGY/ GAS 2006 WASHINGTON STATE ENERGY CODE HEALTH / FOOD SERVICE SEATTLE & KING COUNTY PUBLIC HEALTH 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 ICC REVIEW LETTER III?Im{wl)'il COU OtlCl: 11.8.10 Re: T -0627 Target Store, To a, WA To whom it may concern, 2011 MERCHANDISE REMODEL ELECTRICAL SUBMITTAL 1 am pleased to inform you that the International Code Co uxcil has reviewed these drawings for Target Corporation and has provided appropriate notes and comr emts regarding code compliance, to aid in your review process_ This pre - permit application review is part of a project that provides review by ICC plans examination staff to provide valuable information to you as the local code official having jurisdiction. We would value your input on this program and would like to get your feedback on how your review process was affected_ Approval of the drawings and permit application, of course, rests with you, the code official as the authority having jurisdictions Phillip Grankowski, .Senior Technical Staff, (288- 422 - 7233), has performed the plan review and would be happy to answer any questions you may have_ Also as your Government Relations contact, I can be reached at 888 -422- 7233, ext. 7603, or by email at kstevenson @iccsafe_org Sincere Kraig Stevenson international Code Council Senior Regional Manager State and Local Government Relations Washington Field Office 2122 112th Ave., NE, Suite B -100 Bellevue, WA 98004 Toll Free 888 -422 -7233 ExL 7603 REMODEL SCOPE OF WORK A. PROJECT SCOPE IS LIMITED TO THE INSTALLATION OF FREEZER AND COOLER FIXTURES ON THE EXISTING SALES FLOOR AT THE MARKET AREA AS WELL AS THE INSTALLATION OF A FREEZER /COOLER STORAGE UNIT IN THE BACK STOCKROOM. SCOPE INCLUDES THE ADDITION OF ROOFTOP CONDENSING UNITS AND ASSOCIATED PLUMBING, MECHANICAL AND ELECTRICAL WORK. B. ARCHITECTURAL WORK IS LIMITED TO MINOR DEMOLITION AND REPAIR /REPLACEMENT OF FINISHES. THE EXISTING OCCUPANCY, USE LIFE SAFETY AND EGRESS ARE NOT IMPACTED BY THE COMPLETED WORK. C. EXISTING BUILDING IS FULLY SPRINKLERED. ANY EXISTING FIRE SPRINKLERS AFFECTED BY NEW CONSTRUCTION WILL BE ADJUSTED TO MEET REQUIREMENTS. D. EXISTING COMPACTOR AND ASSOCIATED ITEMS TO BE REPLACED WITH NEW SELF CONTAINED COMPACTOR. THE ALARMS, ELECTRICAL, FIRE SUPPRESSION, AND MECHANICAL SYSTEMS FOR THE NEW COMPACTOR HAVE BEEN REVISED. 0: \Remodels \0627 WA South Center R \_ActiveCAD \0627a0 — 1 — Copy.dgn I— — — VICINITY MAP LOCATION MAP DATE ISSUED ISSUES AND REVISIONS PROJECT TEAM ARCHITECTURAL: DAVID CONTRERAS MULVANNYG2 ARCHITECTURE 601 SW SECOND AVE SUITE 1200 PORTLAND, OR 97204 P: 971.998.1451 RICHARD PESKE, DPM TARGET CORPORATION 50 S. 10TH STREET SUITE 400, TP3 -1165 MINNEAPOLIS, MN 55403 P: 612.761.1588 F: 612.761.3322 STRUCTURAL: NIMESH PARIKH MYERS HOUGHTON & PARTNERS 4500 E. PACIFIC COAST HWY. SUITE 100 LONG BEACH, CA 90804 P: 562.985.3200 MECHANICAL: DOUG SCOTT HARGIS ENGINEERS, INC 600 STEWART ST. SUITE 1000 SEATTLE, WA 98101 P: 206.436.0427 REFRIGERATION: TONY YTUARTE CTA ARCHITECTS ENGINEERS 1185 GROVE ST. BOISE, ID 83702 P: 208.343.3531 ELECTRICAL: CHARLIE MUSSER HARGIS ENGINEERS, INC 600 STEWART ST. SUITE 1000 SEATTLE, WA 98101 P: 206.859.5382 DRAWN BY CHECKED BY ARCHITECTS PROJECT NO. RobH 11 —NOV -2010 07:14 e TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 SHEET INDEX GENERAL G001 PROJECT INFORMATION ELECTRICAL E001 ELECTRICAL SYMBOL LIST & ONE -LINE DIAGRAM ED01 ELECTRICAL DEMOLITION PLAN E111 LIGHTING PLAN E121 SPECIALTY LIGHTING PLAN E211 POWER & SYSTEMS PLANS E221 ROOF POWER PLAN E331 INVESTIGATION CENTER LIGHTING, POWER & SYSTEMS PLANS E381 ELECTRONICS & ENTERTAINMENT POWER & SYSTEMS PLANS E385 DESTINATION BEAUTY POWER & SYSTEMS PLAN E401 MARKET AREA POWER & SYSTEMS PLAN E511 DETAILS & WIRING DIAGRAMS E601 SCHEDULES E931 SPRINKLER SUPERVISORY INITIATING & SIGNALING DEVICE PLAN. E932 INVESTIGATION CENTER ACCESS CONTROL & INTRUSION PLAN TVS1 CCTV PLAN FILE COPY Pannnwo Wa° 040 Plan review approval is subject to Approval of construction docume the violation of approved Fie BY Date: errors and omissions. not authorize ordinance. Rece pt acknowledge'° —"ZOk1 City Of Tukwila BUILDING DIVISION REVISIONS No chances shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan st brnittc.I end may in -'ude additional plan rcv, riv, STORE T062 7 VERSION MR2010 08 08 -06-10 PROJECT CODE 270627 CONFIGURATION LL TITLE REVIEWED FOR PLIANCE WITH NFPA70 - NEC DEC 2 2010 City of Tukwila BUILDING DIVISION PROJECT INFORMATION RECEIVED NOV 19 2010 PERMIT CENTER SHEET G001 T -0627 SOUTH CENTER, WA 1 1200A MAIN CIRCUIT BREAKER 1 GROUND FAULT PROTECTOR v «: ^: : a. , :r v. S BUS ...,; .. of ..,' ps 400A 3P (3) 400A (LPS-RK) NEW 3W 400A. 480V, 3/, 4W, 60HZ BUS W/ GROUND (DP -2) El 100A 3P 200A El 3P El KEY NOTES 11 4 6 RENAME EXISTING PANEL LP -4 AS PANEL LP -12A. LATCH EXISTING CONTACTOR CLOSED &REMOVE 120 VOLT CONTROL CIRCUIT BACK TO SOURCE. REFER TO EMS VENDOR SHOP DRAWINGS. INSTALL DISCONNECT SWITCH IN EXISTING SPACE. PROVIDE FUSES AS INDICATED. PROVIDE AND INSTALL DISCONNECT IN EXISTING SPACE. PROVIDE FUSES AS INDICATED. PROVIDE FUSES AS INDICATED IN EXISTING DISCONNECT SWITCH. PROVIDE AND INSTALL CIRCUIT BREAKER IN EXISTING SPACE. REMOVE EXISTING SWITCH AND FEEDER AND REPLACE WITH NEW. RENAME EXISTING DUPLICATE TRANSFORMER T -6 AS TRANSFORMER T -7. 100A 3P 60A 60A 3P © 3P El (3)90a (LPS-RK) CM 110A (LPS -RK) CM 70A (LPS-RK) C3) 45A , t3) 45A tLPS-RK) (LPS-RK) BONE BASE 1" VIA t.r1 CNN G OA SHE RE! A 3W 3W DISC W /UNIT RTCR -1 DISC W/RTU RTCR -2 31, T -16 T -14 T -15 1.8 CU 1.8 CU 1 ■4 CU PANEL ELECTRICAL SHEET I\ DEX E001 ELECTRICAL SYMBOL LIST & ONE -LINE DIAGRAM ED01 ELECTRICAL DEMOLITION PLAN E111 LIGHTING PLAN E121 SPECIALTY LIGHTING PLAN E211 POWER & SYSTEMS PLANS E221 ROOF POWER PLAN E331 INVESTIGATION CENTER LIGHTING, POWER & SYSTEMS PLANS E381 ELECTRONICS & ENTERTAINMENT POWER & SYSTEMS PLANS E385 DESTINATION BEAUTY POWER & SYSTEMS PLAN E401 MARKET AREA POWER & SYSTEMS PLAN E511 DETAILS & WIRING DIAGRAMS E801 SC HEDU LES E931 SPRINKLER SUPERVISORY INITIATING & SIGNALING DEVICE PLAN E932 INVESTIGATION CENTER ACCESS CONTROL & INTRUSION PLAN TVS1 CCTV PLAN ONE LINE DIAGRAM MUNE/GENERA ::: vNI FAA NOT TO SCALE do- OF AM E„ t.sNyA 80:1208 +.:.. ^: + , SUE GROUND BASE FRAME 'PA :MUNK 1N5. GHD ys "1 ,, ax , 114; GND ;PANEL 1 LP -12A 11 ELECTRICAL SYMBOL LIST 011 0 ee KEY NOTE DESIGNATES OWNER SUPPLIED EQUIPMENT. REFER TO SHEET A601 FOR OWNER FURNISHED EQUIPMENT SCHEDULE. No FLUORESCENT, INCANDESCENT OR HID LUMINAIRE 0 E INDICATES EMERGENCY LIGHTING ILLUMINATED EXIT SIGN - CEILING /WALL (SHADED QUADRANT INDICATES FACE(S). PROVIDE (i)1-0311 DIRECTIONAL ARROWS WHERE INDICATED. I-- JO WALL MOUNT JUNCTION BOX - 18' AFF UNO XX OR CABINET MOUNT JUNCTION BOX 0 CEILING MOUNT JUNCTION BOX XX F = FIRE ALARM SYSTEM S = SECURITY SYSTEM T = LOW VOLTAGE THERMOSTAT - 96' AFF UNO V1 = SINGLE 'F' CONNECTOR VIDEO DIST. COVERPLATE V2 DUPLEX 'F' CONNECTOR VIDEO DIST. COVERPLATE o DUPLEX RECEPTACLE - 18' AFF LINO (GFCI- GROUND FAULT INTERRUPTER) (WP - WEATHER PROOF W/ WHILE IN USE COVER) M:.. QUADRUPLEX RECEPTACLE - 18' AFF UNO OPTIONAL /EMERGENCY RECEPTACLE - 18' AFF UNO SPLIT WIRE RECEPTACLE - 18' AFF UNO 4-PS -> MULTIOUTLET ASSEMBLY, ARROWS DEFINE THE LIMITS OF THE INSTALLATION. RECEPTACLES 12' OC UNO 0 \ J A FLOOR BOX SYSTEMS (LETTER DENOTES OUTLET TYPE, SEE DETAILS) POWER POLE - LETTER DENOTES TYPE - NUMBER DENOTES PRE MANUFACTURED CABLE KIT TYPE SYMBOLS LEGEND GENERAL NOTES: A. DIMENSIONS ARE TO CENTERLINE OF DEVICE OR BOX UNO. B. THE ABOVE SYMBOLS COMPRISE A STANDARD LIST. NOT ALL SYMBOLS MAY APPEAR ON THIS PROJECT -b4 SINGLE -POLE SINGLE -THROW SWITCH - 44' AFF UNO THREE -WAY SWITCH - 44' AFF UNO SWITCH AND PILOT LIGHT - 44' AFF UNO 3 (moo -64K KEY- OPERATED SWITCH - 44' AFF UNO MSS = MOTOR STARTER SWITCH OS = OCCUPANCY (MOTION) SENSOR SWITCH TELEPHONE OUTLET:- 18' AFF UNO WITH 3/4 ' EMPTY CONDUIT TO ABOVE SUSPENDED CEILING OR TO JOIST SPACE IN UNFINISHED SPACES. W INDICATES JUNCTION BOX NO CLOSER THAN 4' FROM FINISHED DOOR FRAME, 44' AFF UNO I-< DMA OUTLET - 18' UNO WITH Y4' EMPTY CONDUIT TO ABOVE SUSPENDED CEILING OR TO JOIST SPACE IN UNFINISHED SPACES. 11111111 T 1- NT HIS CONTROL PANEL LP PANELBOARD HL PANELBOARD HP & LD PANELBOARD TRANSFORMER NEON TRANSFORMER SAFETY SWITCH (POLES NOTED, F INDICATES FUSED. SIZE AS NOTED). COMBINATION STARTER /SAFETY SWITCH MOTOR CONNECTION DAMPER MOTOR LINE VOLTAGE THERMOSTAT - 48' AFF UNO TEMPERATURE SENSOR, 96' AFF UNO WIRING METHOD AND IDENTIFICATION (NOTE: WITHOUT FURTHER IDENTIFICATION SYMBOL INDICATES 1/2 ' CONDUIT WITH 2U12 AWG CONDUCTORS. CROSS LINES INDICATE QUANTITY OF 612 AWG CONDUCTORS AND EXTENDED CROSS LINE W/O DOT INDICATES NEUTRAL CONDUCTOR, W /DOT INDICATES SEPARATE GROUND, ALL IN CODE SIZED CONDUIT. CONDUIT CONCEALED IN CEILING OR WALL CONDUIT CONCEALED IN FLOOR CONDUIT EXPOSED CONDUIT RUN UNDERGROUND (SLOPE TO DRAIN YE0017 MIXER TO PULL BOXES). EXISTING CONDUIT CONCEALED IN CEILING OR WALL TO REMAIN EXISTING CONDUIT EXPOSED TO REMAIN CONDUIT CONDUIT CONDUIT TURNED UP TURNED DOWN CAPPED OR BUSHED BRANCH CIRCUIT HOME RUN TO PANELBOARD (UPPER CODE - PANEL ID. LOWER NUMERALS IDENTIFY CIRCUIT NUMBERS) GROCERY EQUIPMENT NUMBER INDICATES EXISTING DEVICE TO REMAIN 1`Z SYMBOLS WITH SLASHES THROUGH SYMBOL INDICATES EXISTING DEVICE TO BE DEMOLISHED INDICATES EXISTING DEVICE TO BE RELOCATED R SYMBOLS SHOWN WITH LETTER 'R' INDICATES RELOCATED DEVICE Al Olt SYMBOLS SHOWN WITH STANDARD TEXT INDICATES NEW DEVICE //``/ /'`y''( EXISTING CONDUIT CONCEALED IN CEILING OR WALL TO BE DEMOLISHED 46///////y4 EXISTING CONDUIT EXPOSED TO BE DEMOLISHED 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.harg1s.biz T: \Remodels \0627 WA South Center R\ ActiveCAD \0627e001.dcln GROUND GENERAL NOTES FOR TEMPORARY POWER A. COOLER /FREEZER CONNECTIONS: PROVIDE ALL COMPONENTS FOR TEMPORARY POWER TO COOLER /FREEZERS. B. PROVIDE (1) 20A -2P CIRCUIT BREAKER, (1) JUNCTION BOX AND (1) 208 VOLT RECEPTACLE (NEMA 14 -20R), FOR CONNECTION TO FREEZERS. TYPICAL OF 3. PROVIDE MC CABLE WITH 3 810 & 1 #10 GROUND FROM NEAREST 120/208 VOLT NON - CONTACTORED PANELBOARD AND ROUTE TO AREA BEHIND EACH FREEZER. CIRCUIT BREAKERS TO MATCH EXISTING MANUFACTURER AND HAVE INTERRUPTING RATINGS EQUAL TO OR GREATER THAN EXISTING EQUIPMENT. C. PROVIDE (1) 20A -1P CIRCUIT BREAKER. (1) JUNCTION BOX AND (1) 120 VOLT RECEPTACLE (NEMA 5 -20R), FOR CONNECTION TO COOLERS. TYPICAL OF 2. PROVIDE MC CABLE WITH 2 "10 & 1 #10 GROUND FROM NEAREST 120/208 VOLT NON - CONTACTORED PANELBOARD AND ROUTE TO AREA BEHIND EACH COOLER. CIRCUIT BREAKERS TO MATCH EXISTING MANUFACTURER AND HAVE INTERRUPTING RATINGS EQUAL TO OR GREATER THAN EXISTING EQUIPMENT. D. DO NOT CONNECT TO GENERATOR PANELBOARD (TYPICALLY LABELED LPE -1 OR LPE -2) AT PROJECT COMPLETION A. DISCONNECT AND REMOVE EXISTING CIRCUITRY TO TEMPORARY COOLER /FREEZERS. B. DISCONNECT AND REMOVE 208 VOLT BRANCH CIRCUIT FROM PANELBOARD TO FREEZER RECEPTACLE. TYPICAL OF 3. CIRCUIT BREAKER SHALL REMAIN IN PANELBOARD AND BE LABELED 'SPARE'. C. DISCONNECT AND REMOVE 120 VOLT BRANCH CIRCUIT FROM PANELBOARD TO COOLER RECEPTACLE. TYPICAL OF 2. CIRCUIT BREAKER SHALL REMAIN IN PANELBOARD AND BE LABELED 'SPARE'. w „. GENERAL NOTES FOR ALL SHEETS A. MATERIALS, PRODUCTS. DEVICES, FIXTURES, FORMS OR TYPES OF CONSTRUCTION INCLUDED IN THESE SPECIFICATIONS SHALL MEET OR EXCEED THE REQUIREMENTS OF NATIONAL ELECTRICAL CODE (NEC), AMERICAN NATIONAL STANDARD INSTITUTE (ANSI), INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) AND NATIONAL ELECTRICAL MANUFACTURING ASSOCIATION (NEMA). , CALIFORNIA ADMINISTRATIVE CODE: TITLE 24 AND COUNTY OF LOS ANGELES ELECTRICAL CODE. B. MATERIALS AND EQUIPMENT SHALL BE LISTED AND APPROVED BY A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY AS CONFORMING TO THEIR STANDARDS. C. WIRE. CABLES. AND INSULATIONS SHALL CONFORM TO ICEA -NEMA AND NATIONAL ELECTRICAL CODE STANDARDS AND SPECIFICATIONS. USE NEW WIRE AND DELIVER TO THE JOB SITE IN COILS OR ON REELS. EACH COIL /OR REEL SHALL HAVE A LABEL WITH THE MANUFACTURER'S NAME, TRADE NAME OF WIRE, SIZE OF WIRE AND UL LABEL. D. INSTALL OWNER FURNISHED CIRCUIT BREAKERS OR FUSES IN EXISTING PANELBOARDS AS REQUIRED TO FEED CIRCUITRY AS SHOWN ON PLANS OR SHOWN IN SCHEDULES. REWORK (RE- ARRANGE) CIRCUIT BREAKERS WITHIN EXISTING PANELBOARDS TO ACCEPT NEW LOAD CIRCUIT BREAKERS AS REQUIRED. E. EXISTING CIRCUIT NUMBERS ARE SHOWN FOR REFERENCE ONLY. CIRCUIT NUMBERS WERE OBTAINED FROM THE ORIGINAL CONSTRUCTION DOCUMENTS. FIELD VERIFY EXISTING CONDITIONS. F. REFER TO SHEET ED01 FOR ELECTRICAL DEMOLITION. G. COORDINATE POWER OUTAGES WITH OSR 24 HOURS IN ADVANCE. H. INSTALL OWNER FURNISHED CIRCUIT BREAKER HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. INSTALL NEW CIRCUIT BREAKERS WITH INTERRUPTING RATINGS MATCHING OR GREATER THAN EXISTING EQUIPMENT. ■ DATE ISSUED ISSUES AND REVISIONS CONNECTED KVA 8 NOVEMBER 2010 11.8.10 - PERMIT SET -4.0 FEEDER FEEDER PHASE /N NUMBER AMPACITY CONDUCTOR GROUND CONDUCTOR DRAWN BY 3P /3W 3P /4W CONDUIT CONDUIT CD 20 *12 AWG *12 AWG 1 i /2' C. MUSSER Q 30 "10 AWG *10 AWG 1 3/4' 3/4' CHECKED BY 40 *8 AWG #10 AWG 1 3/4' 3/4' 4 R. OLSON *10 AWG 1 1 ' 1 ' Q 70 #4 AWG ARCHITECTS PROJECT NO. 1 11/4' 11/4' 6 85 #3 AWG tt8 AWG i 11/4' 11/4' 0 100 #2 AWG #8 AWG 1 09 -NOV -2010 08:25 -REVIEWED COM � NFPA70 -NEC DEC 21 2414 City of .Tukwila ,BUILDING DIVISION FEEDER SCHEDULE NOTES: 1. FEEDERS ARE 4 WIRE UNO. 2. FEEDER NUMBER WITH 'A' DESIGNATION ARE FULL SIZE CONDUCTORS FOR TRANSFORMER SECONDARIES. EXISTING TRANSFORVER SCHEDULE NAME KVA PRIMARY SECONDARY MOUNTING REMARKS 45 4.6CY 75 4,6417M30”V 208 / 12:0V W WALL OOR FEEUz, PANEL LP-2 FEEC 7 FEEDS., \EW TRANSFORMER SCHEDULE NAME KVA PRIMARY SECONDARY MOUNTING REMARKS T -14 30 480V,311,3W 208/120V,3Jd,4W WALL FEEDS PANEL LP -14 T -15 45 480V,3Jd,3W 208/120V,3/,4W FLOOR FEEDS PANEL LP -12B LOAD SUMMARY T -0627 11108/10 FEEDER SCHEDULE CONNECTED KVA DEMAND FACTOR COPPER CONDUCTORS REMARKS LIGHTING -4.0 FEEDER FEEDER PHASE /N NUMBER AMPACITY CONDUCTOR GROUND CONDUCTOR * OF SETS 3P /3W 3P /4W CONDUIT CONDUIT CD 20 *12 AWG *12 AWG 1 i /2' V2' Q 30 "10 AWG *10 AWG 1 3/4' 3/4' © 40 *8 AWG #10 AWG 1 3/4' 3/4' 4 55 *6 AWG *10 AWG 1 1 ' 1 ' Q 70 #4 AWG *8 AWG 1 11/4' 11/4' 6 85 #3 AWG tt8 AWG 1 11/4' 11/4' 0 100 #2 AWG #8 AWG 1 11/4' 11/2' L) 130 #1 AWG *6 AWG 1 11/4' 2' 8 150 *1/0 AWG *6 AWG 1 2' 2' 8 175 #2/0 AWG 46 AWG 1 2' 2' CF) 200 9/0 AWG #6 AWG 1 2' 2' 10 400 500 KCMIL "3 AWG 1 31/2' 31/2' 40 600 350 KCMIL *1 AWG 2 3' 3' 4E4 800 500 KCMIL #1/0 AWG 2 31/2' 31/2' 4g0 800 500 KCMIL *2/0 AWG 2 31/2' 3/2' CI3) 1200 350 KCMIL N/A 4 3' 3' 4► 1600 600 KCMIL N/A 4 31/2' 31/2' ® 2000 500 KCMIL N/A 6 3%2' 31/2' 16 3000 500 KCMIL N/A 8 31/2' 31/2' (T7) 4000 600 KCMIL N/A 10 31/2` 31/2' ALUMINUM CONDUCTORS FEEDER PHASE /N AMPACITY CONDUCTOR GROUND CONDUCTOR * OF SETS 3P /3W 3P /4W CONDUIT CONDUIT 4 55 *4 AWG *6 AWG 1 11/4' 11/4' Q 70 #2 AWG *6 AWG 1 11/4' 11/4' (6) 85 "2 AWG 6 AWG 1 1' /a' 1%4' (77 100 *1 AWG #6 AWG 1 11/2' 11/2' 8 150 #3/0 AWG *4 AWG 1 2' 2' 9 200 250 KCMIL #4 AWG 1 21/2' 2'/2' 10 400 250 KCMIL *3 AWG 2 21/2' 21/2' 41 600 500 KCMIL *2/0 AWG 2 31 2' 31/2' Cl2) 800 350 KCMIL °3/0 AWG 3 3' 3' 12 800 350 KCMIL *4/0 AWG 3 3' 3' 4) 1200 500 KCMIL N/A 4 3%2' 31/2' girt, 1600 500 KCMIL N/A 6 31/2' 31/2' ® 2000 600 KCMIL N/A 6 4' 4' 16 3000 500 KCMIL N/A 10 4' 4' 4000 600 KCMIL N/A 12 4' 4' grUlIl FEEDER SCHEDULE NOTES: 1. FEEDERS ARE 4 WIRE UNO. 2. FEEDER NUMBER WITH 'A' DESIGNATION ARE FULL SIZE CONDUCTORS FOR TRANSFORMER SECONDARIES. EXISTING TRANSFORVER SCHEDULE NAME KVA PRIMARY SECONDARY MOUNTING REMARKS 45 4.6CY 75 4,6417M30”V 208 / 12:0V W WALL OOR FEEUz, PANEL LP-2 FEEC 7 FEEDS., \EW TRANSFORMER SCHEDULE NAME KVA PRIMARY SECONDARY MOUNTING REMARKS T -14 30 480V,311,3W 208/120V,3Jd,4W WALL FEEDS PANEL LP -14 T -15 45 480V,3Jd,3W 208/120V,3/,4W FLOOR FEEDS PANEL LP -12B LOAD SUMMARY T -0627 11108/10 LOAD DESCRIPTION CONNECTED KVA DEMAND FACTOR DEMAND KVA REMARKS LIGHTING -4.0 1.25 -5.0 1 RECEPTACLES 33.4 0.5 213 2 POWER NON - SEASONAL 147.6 1 147.6 POWER WINTER 26.2 0 0.0 3 MOTORS NON- SEASONAL 0.0 1 0.0 4 MOTORS NS INTERMITTEN' 0.0 0.85 0.0 5 MOTORS SUMMER 0.0 1 0.0 MOTORS WINTER 0.0 0.0 3 KITCHEN EQUIPMENT 0.3 0.65 0.2 6 Net New Load 164.5 KVA 197.9 Amps REMARKS: 1. INCREASED BY 25% FOR CONTINUOUS LOAD. 2. FIRST 10 KVA AT 100 %. 3. NONCONCURRENT WITH MOTORS SUMMER. 4. INCLUDES 25% OF LARGEST MOTOR AT 480V,3 PH. 5. COMPACTOR AND BALER. 6. PER NEC 220 -56. RECEIVED NOV 19 2010 PERMIT CENTER UTILITY METERED LOAD UTILITY LOADS PEAK KW 425.0 POWER FACTOR @ 0.90 PEAK KVA 4722 PEAK KVA 472.2 ADD 25% of PEAK KVA per NEC + 118.1 Total Base Load KVA 590.3 Total Base Load KVA 590.3 Net New Load KVA + 164.5 Total New Load KVA 754.8 Total New Load Amps 908.3 Existing Service Size Amps 1600 TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR2010 08 08 -06 -10 TITLE ELECTRICAL SYMBOL LIST &ONE-LI N E PROJECT CODE 270627 CONFIGURATION LL D IAG RAM SHEET E001 T -0627 SOUTH CENTER, WA • 'I 93 • 1 13' -10 1/2' 1 3":7.10 ;:°13' -10 1/2 R 23 R 35 R 25 ' R V2 V2 Vi Y2 : V2 27 1141 27 27159' 27.: » >.:27 114 27 V2 114'....V1. F9-- 29 29 V2 2911 159' V1 V2 114• V2 2929 -- -29 V2� - -V2 114' ' T9- � T 2 :.._, 159' 2g...2.9 114' 27 V2 114' V2 2.9, V2 ------ V2 V1 27. 114' 2.7 27 V21114'V2V1 29-0- -2929 -i- 159' 27 T--/ 27 V 114' V1 28 159' V1 V2 114' V2 29 29- --- -29 V2 V2 V1- - V1 V2 -V2 29 1114' 2929 159' 29 29 114' 29 l'-10 1 /2. ... 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T: \Remodels \0627 WA South Center R\ ActiveCAD \0627e121.dan 0: SPECIALTY LIGHTING PLAN 11 6" =1' -0" DATE ISSUED ISSUES AND REVISIONS KEY NOTES 8 NOVEMBER 2010 11.8.10 - PERMIT SET RETAINED FROM DEMOLITION OF NEON. 3 COLUMN MOUNTED JUNCTION BOX LOCATED ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. DRAWN BY TO BE LOCATED AT 84' AFF. MOUNT 'S2' LIGHT FIXTURE SO LAMPS ARE IN HORTIZONTAL POSITION. 5 PROVIDE CONNECTION FROM JUNCTION BOX TO EACH SET OF VALANCE LIGHT FIXTURES. REFER TO DETAIL 10/E511. 6 INSTALL DISPLAY LIGHT FURNISHED BY VENDOR. REFER TO ® FOR INSTALLATION REQUIREMENTS. C. MUSSER SHOWN. MOUNT TRACK 1' -7' FROM WALL TO CENTER OF TRACK. CENTER TRACK TO THE CENTER OF CLUSTER, REFER TO A701 FOR CLUSTER LOCATION. CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 —NOV -2010 08:26 GENERAL NOTES A. VERIFY EXACT LOCATIONS OF SPECIALTY LIGHTING, CONDUIT AND POWER POLE WITH SHEET E211 POWER PLAN AND OWNER'S STORE FIXTURE REQUIREMENTS. B. REFER TO TARGET STORE PLANNING AND ELEVATION MATRIX FOR VALANCE LIGHT MOUNTING HEIGHTS. KEY NOTES 1 PROVIDE CONNECTION FROM RELOCATED POWER POLE TO VALANCE LIGHT FIXTURES. WIRING TO BE ROUTED THROUGH BASE OF FIXTURE INTO JUNCTION BOX MOUNTED ON TOP OF FIXTURE. 2 EXISTING J -BOX, CIRCUITRY AND EMS CONTROL RETAINED FROM DEMOLITION OF NEON. 3 COLUMN MOUNTED JUNCTION BOX LOCATED ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. 4 4' OCTAGON JUNCTION BOX FOR MIRROR LIGHTING TO BE LOCATED AT 84' AFF. MOUNT 'S2' LIGHT FIXTURE SO LAMPS ARE IN HORTIZONTAL POSITION. 5 PROVIDE CONNECTION FROM JUNCTION BOX TO EACH SET OF VALANCE LIGHT FIXTURES. REFER TO DETAIL 10/E511. 6 INSTALL DISPLAY LIGHT FURNISHED BY VENDOR. REFER TO ® FOR INSTALLATION REQUIREMENTS. 7 INSTALL OWNER FURNISHED TRACK LIGHTING AS SHOWN. MOUNT TRACK 1' -7' FROM WALL TO CENTER OF TRACK. CENTER TRACK TO THE CENTER OF CLUSTER, REFER TO A701 FOR CLUSTER LOCATION. REVIEWED FOR COMPLIANCE WITH A7 � NBC NFP DEC 2 2010 City (*Tukwila BUILDING DIVISION ■ TARGET STORE SOUTH CENTER WA08_06_10 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR2010_08 TITLE SPECIALTY LIGHTING PLAN PROJECT CODE 270627 CONFIGURATION LL RECEIVED NOV 19 2010 PERMIT CENTER SHEET E121 T -0627 SOUTH CENTER, WA \ ' ',I 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 -- - - - - - — I --- - -H - - - - — HI RTCR -1 (COMPR) 8 110111 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz i T \RPmrnrIPIc \C1497 WA South CpntPr R\ Artiv CAD \0627e221.dan 4 RTCR -2 (COMPR) ROOF POWER PLAN VI 6" =1' -0" LP -12A 5 — H DATE ISSUED ISSUES AND REVISIONS C. REFER TO SPECIFICATIONS SECTION 27 9900 FOR CONDUIT SUPPORT FROM ROOF STRUCTURE DETAIL ® AND® 8 NOVEMBER 2010 11.8.10 - PERMIT SET KEY NOTES 1 REFER TO m FOR DUCT SMOKE DETECTOR DRAWN BY 2 PROVIDE WALK —IN DEFROST HEATER CIRCUIT FROM CONTACTOR FURNISHED IN WALK —IN FREEZER CONDENSING UNIT. PROVIDE 1'C WITH 2 *8 FOR DEFROST HEATER. REFER TO © . E401 3 PROVIDE WALK —IN DEFROST HEATER CIRCUIT FROM CONTACTOR FURNISHED IN WALK —IN MEAT COOLER CONDENSING UNIT. PROVIDE 3/4'C WITH 21'12 FOR DEFROST HEATER. REFER TO © . E401 C. MUSSER 5 ROUTE AND TERMINATE EXISTING EMS COMMUNICATIONS NETWORK TO NEW RTU CONTROL PANEL. REFER TO EMS SHOP DRAWINGS (AVAILABLE FROM GC) FOR ROUTING /TERMINATING INSTRUCTIONS AND EMS VENDOR CONTACT INFORMATION. CALL EMS VENDOR FOR ASSISTANCE AND TO VERIFY NETWORK COMMUNICATIONS AND SENSOR WIRING. 6 PROVIDE 3/4'C FOR LV CABLE FROM CONDENSING UNIT TO REFRIGERATION CONTROL PANEL ABOVE WALK —IN FREEZER. 7 RTCR CONTROL PANEL FURNISHED WITH UNIT. CHECKED BY 8 PROVIDE VC FROM RTCR COMPRESSOR J —BOX TO RTCR CONDENSER J -BOX. PROVIDE 3010 & 1 #10G (480V CONDENSER FEED) & 2 *12 (120V HEATER FEED) FROM RTCR COMPRESSOR TO RTCR CONDENSER VIA CONDUIT. 9 CONNECT TO EXISTING RTU RECEPTACLE. 10 PROVIDE EMPTY 3/4'C BETWEEN RTCR COMPRESSOR J —BOX AND RTCR CONDENSER J—BOX FOR LV SENSORS TERMINATION. R. OLSON COMPRESSOR CONTROL PANEL AND RTCR CONDENSER CONTROL PANEL FOR NETWORK RMS COM LOOP. 12 DUPLEX GFCI RECEPTACLE FACTORY MOUNTED IN RTU -17. 13 COORDINATE FINAL LOCATION OF EXTERIOR CCTV CAMERA'S WITH TARGET'S VOICE /DATA CONTRACTOR ON SITE. PROVIDE WEATHERPROOF CONDUIT RACEWAY PER KEYNOTES 14 & 15. 14 PROVIDE WEATHERPROOF JUNCTION BOX AND ARCHITECTS PROJECT NO. WY 15 PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR PARAPET MOUNTED CCTV CAMERA. PROVIDE 1' CONDUIT TO JUNCTION BOX MOUNTED ON PARAPET. REFER TO DETAIL ©. WY ■ 09 –NOV -2010 08:26 - REVIEWED FOR COMPLIANCE WITH NFPA70- NEC DEC 2 2010 City of Tukwila BUILDING DIVISION GENERAL NOTES A. CIRCUIT NUMBERS ARE FOR REFERENCE ONLY TAKEN FROM EXISTING PLANS. FIELD VERIFY CONDITIONS AT SITE. B. REFER TO SPECIFICATIONS SECTION 27 9900 FOR TYPICAL POWER POLE DETAIL 29 C. REFER TO SPECIFICATIONS SECTION 27 9900 FOR CONDUIT SUPPORT FROM ROOF STRUCTURE DETAIL ® AND® NEOF 115, D. REFER TO SPECIFICATIONS SECTION 27 9900 FOR TYPE MC CABLE SUPPORT FROM STRUCTURE DETAIL ® AND 28 E. ROUTE CONDUITS THROUGH ROOF WITHIN ROOF CURBS. F. ROUTE FEEDER CONDUITS FROM ELECTRICAL PANEL TO THE UNIT DISCONNECT (CIRCUIT BREAKER) FURNISHED WITH THE RTU /DHU. GROUND CONDUIT DIRECTLY TO JUNCTION BOX OF THE UNIT DISCONNECT. REFER TO 4 G. STUB 18' MINIMUM LENGTH CONDUIT FOR FIRE ALARM, AND 18' MINIMUM LENGTH CONDUIT FOR EMS, INTO CONTROL CABINET. SUPPORT WITHIN CABINET. PROVIDE BUSHINGS. REFER TO Ank NOV H. REFER TO SHEET E001 FOR ROOFTOP EQUIPMENT CIRCUITING. KEY NOTES 1 REFER TO m FOR DUCT SMOKE DETECTOR DETAIL. nipy 2 PROVIDE WALK —IN DEFROST HEATER CIRCUIT FROM CONTACTOR FURNISHED IN WALK —IN FREEZER CONDENSING UNIT. PROVIDE 1'C WITH 2 *8 FOR DEFROST HEATER. REFER TO © . E401 3 PROVIDE WALK —IN DEFROST HEATER CIRCUIT FROM CONTACTOR FURNISHED IN WALK —IN MEAT COOLER CONDENSING UNIT. PROVIDE 3/4'C WITH 21'12 FOR DEFROST HEATER. REFER TO © . E401 4 PROVIDE GFC, WP RECEPTACLE. 5 ROUTE AND TERMINATE EXISTING EMS COMMUNICATIONS NETWORK TO NEW RTU CONTROL PANEL. REFER TO EMS SHOP DRAWINGS (AVAILABLE FROM GC) FOR ROUTING /TERMINATING INSTRUCTIONS AND EMS VENDOR CONTACT INFORMATION. CALL EMS VENDOR FOR ASSISTANCE AND TO VERIFY NETWORK COMMUNICATIONS AND SENSOR WIRING. 6 PROVIDE 3/4'C FOR LV CABLE FROM CONDENSING UNIT TO REFRIGERATION CONTROL PANEL ABOVE WALK —IN FREEZER. 7 RTCR CONTROL PANEL FURNISHED WITH UNIT. 8 PROVIDE VC FROM RTCR COMPRESSOR J —BOX TO RTCR CONDENSER J -BOX. PROVIDE 3010 & 1 #10G (480V CONDENSER FEED) & 2 *12 (120V HEATER FEED) FROM RTCR COMPRESSOR TO RTCR CONDENSER VIA CONDUIT. 9 CONNECT TO EXISTING RTU RECEPTACLE. 10 PROVIDE EMPTY 3/4'C BETWEEN RTCR COMPRESSOR J —BOX AND RTCR CONDENSER J—BOX FOR LV SENSORS TERMINATION. 11 PROVIDE EMPTY 3/4'C BETWEEN RTCR COMPRESSOR CONTROL PANEL AND RTCR CONDENSER CONTROL PANEL FOR NETWORK RMS COM LOOP. 12 DUPLEX GFCI RECEPTACLE FACTORY MOUNTED IN RTU -17. 13 COORDINATE FINAL LOCATION OF EXTERIOR CCTV CAMERA'S WITH TARGET'S VOICE /DATA CONTRACTOR ON SITE. PROVIDE WEATHERPROOF CONDUIT RACEWAY PER KEYNOTES 14 & 15. 14 PROVIDE WEATHERPROOF JUNCTION BOX AND 1' LIQUIDTIGHT FLEXIBLE CONDUIT AND FITTINGS TO PARAPET MOUNTED CCTV CAMERA. PROVIDE V LIQUIDTIGHT FLXIBLE CONDUIT TO JUNCTION BOX MOUNTED ABOVE ACCESSIBLE CEILING OF STORE. REFER TO © WY 15 PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING FOR PARAPET MOUNTED CCTV CAMERA. PROVIDE 1' CONDUIT TO JUNCTION BOX MOUNTED ON PARAPET. REFER TO DETAIL ©. WY 1' LIQUIDTIGHT FLEX CONDUIT AND FITTINGS WITH SERVICE LOOP ROOF FLASHING AND MEMBRANE REFER TO 1' CONDUIT IPARAPET MOUNTED CCTV CAMERA. REFER TO INTERIOR JUNCTION BOX EXTERIOR CCTV MOUNTING DETAIL TOP OF PARAPET WEATHERPROOF EXTERIOR JUNCTION BOX. TOP OF BOX MINIMUM 1' BELOW TOP OF PARAPET. FILL ANCHOR HOLES WITH SEALANT RECOMMENDED BY ROOF MANUFACTURER. EXTERIOR WALL NOT TO SCALE TARGET STORE SOUTH CENTER \'VA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR2010_08 08.06_10 TITLE PLAN PROJECT CODE 270627 CONFIGURATION LL ROOF POWER RECEIVED NOV 19 2010 PERMIT CENTER SHEET E221 T -0627 SOUTH CENTER, WA A6 30 A6 30 OS A6 30 A6 30 OS INTERCEPT EXISTING EMERGENCY CIRCUIT, HLE -1/2. 0 ................ 9 A6 LP -15 10,12,14,16,18,20 INVESTIGATION CENTER A6 32 e A6 32 LIGHTING PLAN 12' -6' AFG 1/4" =1' -0" d 48' 22,24 30x72 (H) V AV -17 -1 VAV -17 -9 LP -15 29 (H) 2Lx0£ EAQd1H A6 34 A6 34 f A6 34 34 A6 A6 34 _ 9 34 9 - - - - - -H A6 34 OS A6 34 f A_6 34 VAV -17 -8 0 CNLG29 4 ---- - - - - -- -- ff — ---- - - - - -- — -- -- LP -15 7,9,11,13,15,17 *10 --I- LP -15 1,3 L 0 LP -15 26,28 LIB -15 2,4,6,8 (H) 2Lx0£ • — r 7 -(YA■UO 0 *10 C 4 4 6291NJ 0 VAV -17 -t) 33.35 62913NI 12'12' 28 P -15 U .25.31 VAV -17- 0 3' -0" 30x60 30x60 30 25 62d33 LP -15 VAV -17 -10 629101410 6Zd1J 62d33 4 4 4 :Ha VAN)-17 -1 32 i.i_ �i•i 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T: \Remodels \0627 WA South Center R\ ActiveCAD \0627e331.don LP -15 32,34,36 36 24x60 r S 34 5 0 N) 2 5' -0'31 V1 AFF - -—- INVESTIGATION CENTER POWER & SYSTEMS PLAN V4" =V-0" DATE ISSUED ISSUES AND REVISIONS VERSION MR2o1oo8 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 —NOV -2010 08:58 • GENERAL NOTES A. LIGHT FIXTURE BRANCH CIRCUIT WIRING ON NORMAL POWER SUPPLY IS NOT INDICATED ON THIS DRAWING. ONLY HOME RUNS ARE INDICATED AT THE BEGINNING OF THE CIRCUIT. B. REFER TO ARCH INTERIOR ELEVATIONS FOR EXACT LOCATION OF CEILING MOUNTED SALES FLOOR EXIT SIGNS. C. REFER TO AND \JJ FOR CONDUIT SUPPORT FROM ROOF STRUCTURE. D. REFER TO SHEETS E161 AND E162 FOR LIGHTING CONTROL AND OCCUPANCY SENSOR DETAILS. E. REFER TO ""' AND FOR TYPE MC CABLE SUPPORT FROM STRUCTURE. F. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE PHASING OF DEMOLITION AND NEW CONSTRUCTION. G. COORDINATE ROUGH -IN LOCATIONS WITH ALARMS DRAWINGS - SHEET E901 AND E911. H. CCTV PLAN PROVIDED ONLY AS A REFERENCE FOR LOCATIONS OF CCTV EQUIPMENT. DIVISION 26 REQUIREMENTS SHOWN SHEET TVS1. I. THE ACCESS CONTROL CONTRACTOR SHALL COORDINATE WITH THE DOOR HARDWARE SUPPLIER FOR THE INTERFACE TO THE ACCESS CONTROL SYSTEM. J THE ACCESS CONTROL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS. REVIEWED Etch COMPLIANCE � WITH DEC 2 2010 City of Tukwila BUILDING DIVISION KEY NOTES II El 4 El 6 El 8 9 10 m 14 ID 18 19 20 ES 24 26 28 MOUNT J -BOX ON STRUCTURE ABOVE CEILING. INSTALL MANUFACTURED WIRING SYSTEM BETWEEN JUNCTION BOX AND TYPE 'A' LIGHT FIXTURES ONLY. INSTALL OCCUPANCY SENSOR /POWER SYSTEM (CI- 205 -I) IN CEILING. REFER TO DETAIL 3. THIS SHEET. VERIFY EXISTING EXIT LOCATION AND FUNCTIONALITY. IF NOT FUNCTIONING OR LOCATED PROPERLY, PROVIDE NEW EXIT SIGN TO MATCH EXISTING AND CONNECT TO NEAREST EMERGENCY CIRCUIT. NOT USED. PROVIDE JUNCTION BOX RECESSED AT BASE OF WALL FOR ELECTRICAL IN FURNITURE SYSTEM. PROVIDE METAL COVERPLATE W/ CENTER KNOCKOUT. PROVIDE ELECTRICAL CONNECTION TO FURNITURE POWER FEED CABLE PROVIDED WITH FURNITURE. LOW VOLTAGE CONTRACTOR TO ROUTE TEL /DATA CABLES IN FURNITURE RACEWAY FURNITURE SYSTEM USES A FOUR CIRCUIT '3 + 1' OPTION, CONSISTING OF 4 PHASES. 2 NEUTRALS AND 2 GROUNDS. LOW VOLTAGE CONTRACTOR TO ROUTE TEL /DATA CABLES IN FURNITURE SYSTEM RACEWAY TO 4 PORT FACE PLATE PROVIDED WITH FURNITURE SYSTEM. STUB CONDUIT (3/4' OR AS NOTED) FROM J -BOX TO AREA ABOVE ACCESSIBLE CEILING. PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING. PROVIDE 3/4' CONDUIT FROM JUNCTION BOX TO CCTV CAMERA. STUB CONDUIT OUT 8' FROM FACE OF FINISHED WALL SURFACE. REFER FOR LOCATION OF CCTV CAMERA. TO DRILL 1 3/4' HOLE FOR EXTERIOR CCTV CAMERA CONDUIT & WEATHERPROOF FITTING. WEATHERPROOF FITTING PROVIDED BY VOICE /DATA CONTRACTOR. INSTALL PUSHBUTTON UNDER COUNTER TOP. PROVIDE 3/8' FLEX CONDUIT FROM PUSHBUTTON TO FURNITURE SYSTEM RACEWAY. ROUTE 2a14 AWG TO DOOR STRIKE AT DOOR 118. PROVIDE DOORBELL PB (EDWARDS *1786C-B OR EQUAL) AT 48' ABOVE GRADE. CONNECT TO BUZZER ABOVE ACCESSIBLE CEILING. NOT USED. PROVIDE TRANSFORMER (EDWARDS #592) AND BUZZER (EDWARDS 940 -665) ABOVE ACCESSIBLE CEILING. ROUTE 14/2 CABLE TO PUSHBUTTON AT DOORS 118 AND 126. STUB CONDUIT (3/4' OR AS NOTED) FROM J-BOX TO AREA ABOVE ACCESSIBLE CEILING. VOICE /DATA CONTRACTOR: PROVIDE RG -11 COAXIAL CABLE FROM TV TO EXISTING ANTENNA MAST ON ROOF. PROVIDE J -BOX MOUNTED AT 48' AFF FOR CARD READER. INSTALL 18/4 CONTROL CABLE FURNISHED BY EMS VENDOR. MOUNT JUNCTION BOX AND T -STAT AT 60' & PROVIDE TERMINATIONS OF CONTROL CABLE. PROVIDE CONNECTION TO ELECTRIC STRIKE. INSTALL PUSHBUTTON UNDER COUNTER TOP. PROVIDE 3/8' FLEX CONDUIT FROM PUSHBUTTON TO FURNITURE SYSTEM RACEWAY. ROUTE 23'14 AWG TO DOOR STRIKE AT DOOR 126. STUB CONDUIT (3/4' OR AS NOTED) FROM J -BOX TO AREA ABOVE ACCESSIBLE CEILING. TO DOORBELL BUTTON AT EXTERIOR FRONT DOOR. REFER TO NOT USED. PROVIDE WALL MOUNT AIPHONE AUDIO ONLY TENANT STATION AIPHONE #GH- 1AD -SW. WIRE TO DISTRIBUTION POINT IN SERVER ROOM 115. AIPHONE DISTRIBUTION POINT. PROVIDE 8'X8'X4' HOFFMAN BOX WITH TYPE 66 PUNCHDOWN BLOCK. PROVIDE DESK MOUNT AIPHONE AUDIO ONLYTENANT STATION AIPHONE aGH- IAD -SW WITH DESK STAND. WIRE TO DISTRIBUTION POINT IN SERVER ROOM 115. CEILING 3' MUDRING HOLE CEILING ATTACHMENT RING OCCUPANCY SENSOR OCCUPANCY SENSOR MOUNTING SCREW, X2 OCCUPANCY COVER NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF CEILING MOUNTED MOTION SENSORS. CI -205 -1 SENSOR CEILING TILE MOUNTING uo- olt90 NOT TO SCALE CEILING HEIGHT CALLED OUT ON DRAWING. CENTER LINE OF POWER & SYSTEMS DEVICES N- I- w U CO CD z 1= z 0 U- 0 W z_ J w I— z w U DUPLEX RECEPTACLE & ANTENNA OUTLET MOUNTED IN THE CENTER OF MONITOR MOUNTING BRACKETS LCD MONITOR PROVIDED BY TARGET, INSTALLED BY TARGETS LOW VOLTAGE VENDOR MONITOR MOUNTING BRACKET PROVIDED BY TARGET, INSTALLED BY FIXTURE INSTALLATION CONTRACTOR CENTER MOUNTING BRACKET & DEVICES A MINIMUM OF 4' -0' FROM CORNER WALL (TYP.) FLOOR TV ELEVATION DETAIL NOT TO SCALE TARGET STORE SOUTH CENTER `NA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR2o1oo8 TITLE INVESTIGATION CENTER PROJECT CODE 270627 CONFIGURATION LL LIGHTING, POWER & SYSTEMS PLAN RECEIVED NOV 19 2010 PERMITCENTER SHEET E331 T -0627 SOUTH CENTER, WA CEILING LPE -1/7 LP -14/42 LP -14 1,3,5,7 16,18,25,27,29 PS 24' LP -14/42 22 • *10 = 25 36' TV WALL El 22 a -1) 3(0 16' 16' 3@ 13 16' 16' X13 16' X13 6 1/2" 37' 18 6 1/2" 20 a -2) 31 20 I % 0 1'A' SET / OF TV'S / 2' -0' >' I I #10 \ I I \ I I 37' \ 1 3.7:::: . 1 I I t- 4016'1 1 1 37)n V1 /I/ 1\ 16' X29 / 36'/ / \ /1 A 7, -1" 16' c19 °10 _ 0 LP -1�1 2,4,68, 17,19,21,37 22 • #10 = 2 LP -14 9,11,10,12,15 22.24,28,30 \ 1'C 6' -11" 2' -0" 17 16' 16' 36' c@29 36' TYP ELECTRONICS BOAT POWER & SYSTEMS PLAN } 1/2"=V-0" LPE -1/7 LP -14/42 } ELECTRONICS POWER & SYSTEMS PLAN 1/4"=1'-0" 16' .17Cgo / A 1 7 _ 16'I�, 1.6.' X17 :_TYP 0 N N 0 2 BLUE RAY STORE SHELVES TV TRAC INSTALLEI VOICE /DA CONTRAC STORE S FL LABEL COVERPLATE 'WARNING 208 VOLT IN JUNCTION BOX' (TYPICAL AT TV WALL) TV WALL ELEVATION E6 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 BASE DECK SPLITTER BOARD INSTALL BY VOICE /DATA CONTRACTOR P = POWER JUNCTION BOX - WITH DUPLEX RECEPTACLE V2 = VIDEO DISTRIBUTION JUNCTION BOX - DUPLEX NOT TO SCALE HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T. \P.,,.,,-Jole \n,')7 WA Snll +h C'cn +ar R\ Ar +ivoC'Af) \(1697, 1 rinn LP -14 32,34,36 *10 18 2 28 36' 30 30 36' 36' TYP (a -1)Zc2 16' 22 16' 16' X22 2 TYP TYP (a- 1)'24 24© 16' 16' 0Q24 TYP SIM 6 ENTERTAINMENT POWER & SYSTEMS PLAN NOTES: 1. CONCEAL CONDUIT AND CABLE FROM SIGHT OF GUEST. 2. DRILL HOLES AS REQUIRED TO ROUTE CONDUIT & COMPONENT CABLES THRU FIXTURE. PROVIDE BUSHING IN DRILLED HOLES TO PROTECT CONDUIT AND CABLES. 3. REFER TO SPEC SECTIONS 27 4100 & 27 4101 FOR REQUIREMENTS. LCD FIXTURE MOUNTING BRACKET Y4".-1'-0" INTERACTIVE DISPLAY POWER POLE INSTALL OWNER PROVIDED LCD 7,.— MONITOR PER MANUFACTURERS REQUIREMENTS INSTALL OWNER PROVIDED PATCH CABLE FROM RCA COUPLERS TO LCD MONITOR RCA INPUTS (DO NOT INSTALL COMPONENT CABLE DIRECTLY TO LCD MONITOR) FIXTURE COVERPLATE JUNTION BOX FOR POWER. PROVIDE RECEPTACLE & COVERPLATE DIRECTIONAL LOW PROFILE SPEAKER BAR ENTERTAINMENT LCD MONITOR INSTALLATION DETAIL NOT TO SCALE DATE ISSUED ISSUES AND REVISIONS VERSION MR2010_08 08 -06 -10 8 NOVEMBER 2010 , - PERMIT SET DRAWN BY C. MUSSER CHECKED BY I- R. OLSON n 1 v v n v n v v n n I acI V2 IP I n n v n n n n o n I �•-1-•�•�.�•�•�• •�• -1-•� Q. Q IP V2 I n v n n v n n n v n I �.--•�•�. �•�•�•�•�._I_. Q V2 IPI DAY FORn d- 0 I n••• „ pp V2 P ., „ „ . n I —•— -- — - -._ I I I pp V2 P I „ � . n R MOUNT n .. „ I n o V2 PI ob in IELVES OOR • i I I POWER JUNCTION BOX IN BASE DECK I I I I Ii OF TV WALL. PROVIDE CONDUIT FROM BASE DECK JUNCTION BOX TO POWER JUNCTION BOX MOUNTED IN TV WALL (TYP.) I • b TV WALL ELEVATION E6 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 BASE DECK SPLITTER BOARD INSTALL BY VOICE /DATA CONTRACTOR P = POWER JUNCTION BOX - WITH DUPLEX RECEPTACLE V2 = VIDEO DISTRIBUTION JUNCTION BOX - DUPLEX NOT TO SCALE HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T. \P.,,.,,-Jole \n,')7 WA Snll +h C'cn +ar R\ Ar +ivoC'Af) \(1697, 1 rinn LP -14 32,34,36 *10 18 2 28 36' 30 30 36' 36' TYP (a -1)Zc2 16' 22 16' 16' X22 2 TYP TYP (a- 1)'24 24© 16' 16' 0Q24 TYP SIM 6 ENTERTAINMENT POWER & SYSTEMS PLAN NOTES: 1. CONCEAL CONDUIT AND CABLE FROM SIGHT OF GUEST. 2. DRILL HOLES AS REQUIRED TO ROUTE CONDUIT & COMPONENT CABLES THRU FIXTURE. PROVIDE BUSHING IN DRILLED HOLES TO PROTECT CONDUIT AND CABLES. 3. REFER TO SPEC SECTIONS 27 4100 & 27 4101 FOR REQUIREMENTS. LCD FIXTURE MOUNTING BRACKET Y4".-1'-0" INTERACTIVE DISPLAY POWER POLE INSTALL OWNER PROVIDED LCD 7,.— MONITOR PER MANUFACTURERS REQUIREMENTS INSTALL OWNER PROVIDED PATCH CABLE FROM RCA COUPLERS TO LCD MONITOR RCA INPUTS (DO NOT INSTALL COMPONENT CABLE DIRECTLY TO LCD MONITOR) FIXTURE COVERPLATE JUNTION BOX FOR POWER. PROVIDE RECEPTACLE & COVERPLATE DIRECTIONAL LOW PROFILE SPEAKER BAR ENTERTAINMENT LCD MONITOR INSTALLATION DETAIL NOT TO SCALE DATE ISSUED ISSUES AND REVISIONS VERSION MR2010_08 08 -06 -10 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 -NOV -2010 08:27 GENERAL NOTES A. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. B. UNDER SLAB CONDUIT SHALL BE Y4' MINIMUM, UNO. C. INSTALL OWNER FURNISHED POWER POLE 0 AND WIRING FROM J -BOX TO POWER POLES. D. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. E. REFER TO SHEET E511 FOR FLOOR BOX DETAILS. F. PROVIDE SEPARATE NEUTRAL FOR EACH CASH REGISTER CIRCUIT. G. REFER TO CjO' FOR DEVICE HEIGHTS AT TV WALL. H. LOCATE EXISTING DISTRIBUTION FEEDER FROM MAIN SWITCHBOARD TO FRONT ELECTRICAL ROOM PRIOR TO SAW - CUTTING FLOOR. J. HOMERUNS, WIRING AND DEVICES IN ELECTRONICS DEPARTMENT ARE PRE MANUFACTURED AND OWNER FURNISHED. K. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING SYSTEM. REFER TO PRE MANUFACTURES INSTALLATION DRAWINGS FOR INSTALLATION REQUIREMENTS. "LIO 01(,0 INSTALL PRE- MANUFACTURED RECEPTACLE INSIDE OF FIXTURE. MOUNT RECEPTACLE TO RAIL OF FIXTURE WITH 1/4' X 1' PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED. • KEY NOTES 0 4 6 8 9 10 m 14 16 18 19 STUB CONDUIT (Y4' UNO) FROM J -BOX TO AREA ABOVE ACCESSIBLE CEILING. MOUNT RECEPTACLE FACE UP ON TOP OF GONDOLA. ROUTE WIRING IN Y4' FLEX CONDUIT BETWEEN JUNCTION BOX, POWER POLE OR FLOOR BOX TO RECEPTACLES. CONCEAL WITHIN STORE FIXTURES. VOICE /DATA CONTRACTOR TO MOUNT BASE DECK SPLITTER BOARD IN BASE DECK OF TV WALL. FOR LOCATION & REQUIREMENTS REFER TO MOUNT RECEPTACLES AND J -BOXES FOR TV WALL POWER AND VIDEO IN STORE FIXTURING. 20 24 VOICE /DATA CONTRACTOR TO PROVIDE (1) RG -11 COAX CABLE FROM BAES DECK SPLITTER BOARD TO VIDEO DISTRIBUTION RACK. VOICE /DATA CONTRACTOR TO PROVIDE COMPONENT CABLES FOR 'C' MONITOR TO VIDEO DISTRIBUTION RACK. e STUB 1 1/4' CONDUIT BELOW BASE DECK OF TV WALL FOR BASE DECK SPLITTER BOARD COAXIAL CABLE HOME RUN. VOICE /DATA CONTRACTOR TO PROVIDE COMPONENT CABLES FOR 'B' MONITOR TO VIDEO DISTRIBUTION RACK. E6 VOICE /DATA CONTRACTOR TO ROUTE COMPONENT CABLE TO RCA COUPLER. CONCEAL CABLE WITHIN STORE FIXTURE. INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. INSTALL RECEPTACLE AT END CAP OF FIXTURE. CONCEAL CONDUIT AND COMPONENT CABLE IN FIXTURE. MOUNT RECEPTACLE AND JUNCTION BOX IN MILLWORK OF FIXTURE. ROUTE WIRING VIA 3/4' FLEX CONDUIT IN KICK SPACE OF FIXTURE. PROVIDE 3/4' FLEX CONDUIT FROM THE FLOOR BOX TO THE JUNCTION BOX DESCRIBED IN KEY NOTE 13. IN ELECTRONICS DEPARTMENT, INSTALL RECEPTACLES AND VIDEO JUNCTION BOXES HORIZONTALLY IN FREE STANDING GONDOLAS. PROVIDE B -LINE BB10 BOX ELIMINATOR OR EQUAL FOR VIDEO DISTRIBUTION SYSTEM COVERPLATE. PROVIDE MULTIOUTLET ASSEMBLY WITH OUTLETS 12' ON CENTER, ALTERNATE CIRCUITS. MOUNT MULTIOUTLET ASSEMBLY AT 36'AFF TO GONDOLA FIXTURE UPRIGHTS. MOUNT J-BOX ON STRUCTURE ABOVE CEILING. INSTALL MANUFACTURED WIRING SYSTEM BETWEEN JUNCTION BOX AND POWER POLE FIXTURE UNO PROVIDE RECEPTACLE WITH BELL BOX FOR INTERACTIVE DISPLAY. SURFACE MOUNT RECEPTACLE HORIZONTALLY TO PEG BOARD. CONCEAL FLEXIBLE CONDUIT WITHIN FIXTURE. REFER TO INSTALL RECEPTACLE & DATA OUTLET IN BASE DECK OF GONDOLA FOR LEARNING CENTER INTERACTIVE DISPLAY. MOUNT RECEPTACLE & DATA OUTLET TO FIXTURE RAIL. REFER TO INSTALL PRE MANUFACTURED MAINRUN CABLE FROM POWER DISTRIBUTION BOX TO PANEL LP -14 ROUTE PRE MANUFACTURED EXTENDER CABLE INSIDE OF WALL TO THE BASE DECK OF THE FIXTURE. STUB OUT EXTENDER CABLE 2'AFF. INSTALL PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO BASE DECK OF FIXTURE. REFER TO SUPPORT PRE - MANUFACTURED CONNECTORS A MINIMUM 3' ABOVE FINISHED FLOOR FROM UNDERSIDE OF BASE DECK TO AVOID MOISTURE FROM PENETRATING CONNECTORS. SUPPORT CONNECTORS ON EACH END UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. 211 TYP ■ ■ ■ ... ROUTE PRE - MANUFACTURED WIRING IN BASE DECK OF FIXTURE REVIEWED Rol CQMPA7HOCITH NEC NFP ELECTORNICS - TYPICAL WIRING ELEVATION POWER DETAIL DEC 21 2010 City of Tukwila BUILDING DIVISION NOT TO SCALE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE TO627 VERSION MR2010_08 08 -06 -10 TITLE ELECTRONICS & POWER PROJECT CODE 270627 CONFIGURATION LL ENTERTAINMENT & VC SYSTEMS PLANS RECEIVED NOV 19 2010 PERMIT CENTER ■ SHEET E381 T -0627 SOUTH CENTER, WA 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T.\ D., ,,...lele\ (1A')7 \A /A C.,.. +h ren +er Q\ Ar•+ivcrAI7\ (1/r77ag51,6 r4rrn Co -1) a -1) 8 TYP 11 11 1 TYP TYP TYP (0 -.1).. 9 LP -6 191'21,16,18, 20 19 a -1) 16 DESTINATION BEAUTY POWER & SYSTEMS PLAN t 1/4" =1' -0" TYP SIM GENERAL NOTES A. HOMERUNS, WIRING AND DEVICES IN COSMETICS DEPARTMENT ARE PRE MANUFACTURED AND OWNER FURNISHED. B. INSTALL OWNER FURNISHED PRE MANUFACTURED WIRING SYSTEM. REFER TO PRE MANUFACTURES® INSTALLATION DRAWINGS FOR INSTALLATION E1 REQUIREMENTS. C. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. D. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. E. REFER TO SPECIFICATION SECTION 27 9900 FOR CONDUIT SUPPORT FROM ROOF STRUCTURE DETAILS ® & F. REFER TO SPECIFICATION SECTION 27 9900 FOR TYPE MC CABLE SUPPORT FROM STRUCTURE DETAILS �� & F. COORDINATE ROUGH -IN LOCATIONS WITH ALARM DRAWINGS. KEY NOTES II 4 6 U 8 9 INSTALL PRE MANUFACTURED POWER DISTRIBUTION BOX ABOVE ACCESSIBLE CEILING. INSTALL PRE MANUFACTURED MAINRUN CABLE FROM POWER DISTRIBUTION BOX TO PANEL LP -6. INSTALL PRE MANUFACTURED EXTENDER CABLE FROM POWER DISTRIBUTION BOX TO SPLITTER MOUNTED IN BASE DECK OF FIXTURE. INSTALL PRE MANUFACTURED SPLITTER IN BASE DECK OF FIXTURE. ROUTE PRE MANUFACTURED EXTENDER CABLE THROUGH TOE KICK OPENING. MOUNT PRE MANUFACTURED RECEPATCLE TO FIXTURE RAIL IN BASE DECK OF FIXTURE. REFER TO ROUTE PRE MANUFACTURED EXTENDER CABLE IN BASE DECK OF FIXTURE. ROUTE PRE MANUFACTURED EXTENDER CABLE INSIDE OF WALL TO THE BASE DECK OF THE FIXTURE. STUB OUT EXTENDER CABLE 2'AFF. SUPPORT PRE - MANUFACTURED CONNECTORS A MINIMUM 3' ABOVE FINISHED FLOOR FROM UNDERSIDE OF BASE DECK TO AVOID MOISTURE FROM PENETRATING CONNECTORS. SUPPORT CONNECTORS ON EACH END OF UTILIZING SUPPORT WIRES OR STRAPS ATTACHED TO BOTTOM OF FIXTURE RAIL OR UNDERSIDE OF THE BASE DECK COVER. TYPICAL. ll OWNER FURNISHED PRE MANUFACTURED RECEPTACLE. MOUNT RECEPTACLE TO BASE RAIL OF FIXTURE. T YP MAINTAIN 3 1/2' OF CLEARANCE FROM BACK OF FIXTURE RAIL WHEN INSTALLING BASE DECK RECEPTACLE. NOTE: MOUNT BASE DECK RECEPTACLE TO FIXTURE RAIL WITH 1/4 ' X 1' PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED DESTINATION BEAUTY - TYPICAL WIRING E1 ELEVATION POWER DETAIL NOT TO SCALE DATE ISSUED ISSUES AND REVISIONS TARGET STORE SOUTH CENTER WA 301 STRA NDER BLVD TUKWILA WA 98188 8 NOVEMBER 2010 11.8.10 - PERMIT SET CONFIGURATION LL POWER & PLAN DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. .. ■ 09 -NOV -2010 08:27 1,10 Clo0 REVIEWED COMPLIANCE WITH NFPA70 - NEC DEC 2 2010 City of Tukwila BUILDING DIVISION RECEIVED NOV 19 2010 PERMIT CENTER SHEET E385 T -0627 SOUTH CENTER, WA TARGET STORE SOUTH CENTER WA 301 STRA NDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR201008 08.06.10 TITLE DESTINATION BEAUTY SYSTEMS PROJECT CODE 270627 CONFIGURATION LL POWER & PLAN RECEIVED NOV 19 2010 PERMIT CENTER SHEET E385 T -0627 SOUTH CENTER, WA REFRIGERATION EQUIPMENT SCHEDULE A. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. B. CONDUIT IN UNFINISHED SPACES TO BE EXPOSED. C. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. REFR SYST REFRIGERATION CASES LIGHTING CONTACTORED CIRCUIT FANS &ANTI -SWEAT FRAME HEATERS REFR SYST REFRIGERATION CASES ANTI -SWEAT HEATERS FANS & ANTI -SWEAT FRAME HEATERS DOOR HTRS NON DUAL TEMP DOOR HTRS DUAL TEMP CASES DOOR & FRAME HTRS DUAL TEMP CASES 2.4 CONTACTORED CIRCUIT NOT CONTACTORED NOT CONTACTORED # MODEL CASE TYPE 0) Li 2 < < a r1 U a w <a- 2 w < I- rn w2 > < rs3 < < C, a E i- < uli < a D 0 Cc U V) _1 3 Et 2 ¢ IX < a U cn _, 5 1 Q CC < a U I- cn Ii U CC Q < a U A01 OWIZIOWEZ FROZEN _ to �o o. i-¢ W z CL 1- U to Q I- W Z a. U to Q ill _1 a I_ 5 U fn ¢ ...1 a. 1- U V 808 RMN 5 DOORS W ISLAND - OW IZ 1.3 LP -12B 0.9 1.5 2.6 3.5 LP -12B 23 10 8' ISLAND - OWIZ 0.9 B09 22 3.5 LP -12B 23 17 17 1.3 1.0 2.0 2.0 t3 1.0 4.6 4.0 END CAP - OWEZ 10 10 1.5 1.1 0.4 1.6 2.0 LP -12B 23 B10 RMN 5 DOORS 4 DOORS REFRIG 1.3 1.0 END CAP - OWEZ 17 17 1.5 1.2 0.4 2.2 t8 1.6 2.0 LP -12B 23 A02 RLN FROZEN ABO1 RLN 2 DOORS DUAL TEMP 0.5 LP -12B 19 0.6 0.7 02 2.2 LP -12B 14 4 DOORS 1.0 LP -12B 1 2.0 1.4 1.8 5.2 LP -12B 25 3.1 LP -12B 16 0.5 LP -12B 19 4 DOORS 1.0 LP -12B 1 2.0 1.4 t8 5.2 LP -12B 25 3.1 LP -12B 16 A03 RLN FROZEN RLN 2 DOORS DUAL TEMP 0.5 LP -12B 19 0.6 0.7 0.9 2.2 LP -12B 14 5 DOORS t3 LP -12B 1 2.6 2.1 22 6.9 LP -12B 27 3.9 LP -12B 18 21 t8 2.0 4 DOORS 1.0 LP -12B 1 2.0 1.4 12 5.2 LP -12B 27 3.1 LP -12B 18 4 ABM A04 RLN FROZEN 12 LP -12B 21 t8 2.0 3.8 LP -12B 32 4 DOORS t0 LP -12B 3 2.0 1.4 1.8 52 LP -12B 29 3.1 LP -12B 20 4 DOORS t0 LP -12B 3 2.0 1.4 1.8 52 LP -12B 29 3.1 LP -12B 20 A05 RLN FROZEN 5 DOORS 1.3 LP -12B 3 2.6 2.1 2.2 6.9 LP -12B 31 3.9 LP -12B 22 4 DOORS 1.0 LP -12B 3 2.0 1.4 1.8 5.2 LP -12B 31 3.1 LP -12B 22 A06 RLN FROZEN 4 DOORS 1.0 LP -12B 5 2.0 1.4 1.8 52 LP -12B 33 3.1 LP -12B 24 4 DOORS 1.0 LP -12B 5 2.0 1.4 1.8 5.2 LP -12B 33 3.1 LP -12B 24 A07 RLN FROZEN 5 DOORS 1.3 LP -12B 5 2.6 2.1 2.2 6.9 LP -12B 35 3.9 LP -12B 26 4 DOORS 1.0 LP -12B 5 2.0 t4 12 5.2 LP -12B 35 3.1 LP -12B 26 A08 P5FGN FROZEN 5 DOORS 2.9 LP -12B 7 3.3 2.0 3.8 9.1 LP -12B 37 6.1 LP -12B 28 3 DOORS 1.8 LP -12B 7 1.8 2.0 2.3 6.1 LP -12B 39 3.6 LP -12B 28 A09 RLN FROZEN 5 DOORS 13 LP -12B 7 2.6 2.1 22 6.9 LP -12B 41 3.9 LP -12B 30 4 DOORS 1.0 LP -12B 7 2.0 t4 1.8 52 LP -12B 41 3.1 LP -12B 30 B01 05M REFRIG 6' OPEN CASE 1.9 LP -12B 9 0.5 0.5 LP -12B 2 B02 O5M REFRIG 12' OPEN CASE 3.5 LP -12B 11 0.9 0.9 LP -12B 4 12' OPEN CASE 3.5 LP -12B 11 0.9 0.9 LP -12B 4 8' OPEN CASE 2.4 LP -12B 11 0.7 0.7 LP -12B 4 B03 05M REFRIG 12' OPEN CASE 3.5 LP -12B 9 0.9 0.9 LP -12B 2 B04 05M REFRIG 12' OPEN CASE 3.5 LP -12B 13 0.9 0.9 LP -12B 6 8' OPEN CASE 2.4 LP -12B 13 0.7 0.7 LP -12B 6 B05 05M REFRIG 12' OPEN CASE 3.5 LP -12B 13 0.9 0.9 LP -12B 6 12' OPEN CASE 3.5 LP -12B 13 0.9 0.9 LP -12B 6 B06 05M REFRIG 12' OPEN CASE 3.5 LP -12B 15 0.9 0.9 LP -12B 8 8' OPEN CASE 2.4 LP -12B 15 0.7 0.7 LP -12B 8 B07 05M REFRIG 1Z OPEN CASE 3.5 LP -12B 15 0.9 0.9 LP -12B 8 12' OPEN CASE 3.5 LP -12B 15 0.9 0.9 LP -12B 8 T.nR,, 111 FIJ010 REFRIGERATION SCHEDULE NOTES: CIRCUITS ARE 120V /1PH, 2#10, #10GRD MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. REFRIGERATION EQUIPMENT SCHEDULE A. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. B. CONDUIT IN UNFINISHED SPACES TO BE EXPOSED. C. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. C01 WALK -IN FREEZER RM 181 1 PROVIDE 11/4'C HOMERUN FOR POWER WIRING. 3.0 REFR SYST REFRIGERATION CASES LIGHTING CONTACTORED CIRCUIT FANS & ANTI -SWEAT FRAME HEATERS DO1 WALK -IN COOLER RM 180 ANTI -SWEAT HEATERS 2.4 6 PROVIDE IT FROM BELOW REFRIGERATED CASE TO LP -13 DOOR HTRS NON DUAL TEMP DOOR HTRS DUAL TEMP CASES DOOR & FRAME HTRS DUAL TEMP CASES WALK -IN MEAT COOLER CONTACTORED CIRCUIT NOT CONTACTORED NOT CONTACTORED # MODEL USE 0 0- d 1 j z I- „ U £1 0 < tu Q VENT AMPS CO Cl- d Q _ to �o o. i-¢ W z CL 1- U to Q I- W Z a. U to Q ill _1 a I_ 5 U fn ¢ ...1 a. 1- U V 808 RMN 5 DOORS REFRIG 1.3 LP -12B 17 1.5 2.1 22 5.8 LP -12B 10 B09 P5NGN 4 DOORS 3 DOORS REFRIG 2.4 1.9 LP -128 LP -12B 17 17 1.3 1.0 2.0 2.0 t3 1.0 4.6 4.0 LP -128 LP -12B 10 10 1.5 1.1 LP -128 34 LP -12B 34 B10 RMN 5 DOORS 4 DOORS REFRIG 1.3 1.0 LP -12B LP -12B 17 17 1.5 1.2 2.1 1A 2.2 t8 5.8 4.4 LP -12B LP -128 12 12 ABO1 RLN 2 DOORS DUAL TEMP 0.5 LP -12B 19 0.6 0.7 02 2.2 LP -12B 14 1.5 LP -12A 2 ABO2 RLN 2 DOORS DUAL TEMP 0.5 LP -12B 19 0.6 0.7 0.9 2.2 LP -12B 14 1.5 LP -12A 2 ABO3 RLN 2 DOORS DUAL TEMP 0.5 LP -12B 19 0.6 0.7 0.9 2.2 LP -12B 14 t5 LP -12A 2 ABO4 P5FGN 3 DOORS DUAL TEMP 1.8 LP -12B 21 t8 2.0 3.8 LP -12B 32 5.9 LP -12A 4 ABM P5FGN 3DOORS DUAL TEMP 12 LP -12B 21 t8 2.0 3.8 LP -12B 32 T.na,, 5.9 111sro n1n LP -12A 4 REFRIGERATION SCHEDULE NOTES: CIRCUITS ARE 120V /1PH, 2 #10, #10 GRD MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. WALK -IN EQUIPMENT SCHEDULE A. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. B. CONDUIT IN UNFINISHED SPACES TO BE EXPOSED. C. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. C01 WALK -IN FREEZER RM 181 1 PROVIDE 11/4'C HOMERUN FOR POWER WIRING. 3.0 2 PROVIDE VC IN CHASE FOR LV CABLE. PROVIDE LP -13 8,10 Note 2 DO1 WALK -IN COOLER RM 180 5 POWER - 1'C HOMERUN TO ELECTRICAL PANEL. 2.4 6 PROVIDE IT FROM BELOW REFRIGERATED CASE TO LP -13 2 Note 1 D02 WALK -IN MEAT COOLER t7 LP -13 14,16 Note 2 D03 WALK -IN PROD. COOLER 32 LP -13 18 Note 1 D04 DRY STORAGE COIL 1.3 ARCHITECTS PROJECT NO. LP -13 7 Note 1 REFRIGERATION SCHEDULE NOTES: 1. CIRCUITS ARE 120V /1PH, 2#10, #10 GRD MINIMUM, UNLESS NOTED OTHERWISE. NO COMMON NEUTRALS PERMITTED. 2. CIRCUITS ARE 208V /1PH, 2 #10, #10 GRD MINIMUM. In z RLN4 RLN4 RLN4:. (A02) RLN4 (A03) RLN5 A CI (ABO) a (T30-6) 05M -12 05M -12 (B07) REMS -4 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 - n n I 11 /1 / /1'7 1 A/ A C H A R G I S Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz n\ A_ie___r"Ar' \/1Ln7_Ar1 _- FREEZER, COOLER, MEAT, PRODUCE & (B04) 05M -12 (B04) 05M -8 (B05) LP -12A 1 05M -12 (A01C) 13 \ (BO7) 05M -12 88' (B05) 05M -12 (A01A) OWIZ z z u7 0 REFRIGERATION GENERAL NOTES A. INSTALL LOW VOLTAGE CABLE FROM REFRIGERATION CONTROL PANELS TO ROOFTOP CONDENSING UNIT, WALK -IN COOLERS AND FREEZERS, ALARM PANEL IN GUEST SERVICES. DOOR HEATER CONTROLLER AND EACH SALES FLOOR REFRIG CASE. CABLE FURNISHED BY REMS VENDOR. FINAL CONNECTIONS BY REMS CONTRACTOR. REFER TO SHEET R621 FOR REMS WIRING DETAILS. B. INSTALL LOW VOLTAGE CABLE TO THE CONNECTION POINT AT TOP OF EACH SALES FLOOR CASE. C. DO NOT TURN ON ELECTRICAL POWER TO THE LIGHTS AND THE FRAME & DOOR HEATERS UNTIL THE REFRIGERATION HAS BEEN TURNED ON. D. REFER TO DETAIL 1/E511 FOR COOLER /FREEZER CONDUIT PENETRATIONS E. LOCATE EXISTING DISTRIBUTION FEEDER FROM MAIN SWITCHBOARD TO FRONT ELECTRICAL ROOM PRIOR TO SAW- CUTTING FLOOR. GENERAL NOTES A. REFER TO SHEET E601 FOR CONTACTOR CONTROLLED CIRCUITS. B. CONDUIT IN UNFINISHED SPACES TO BE EXPOSED. C. STORE FIXTURES ARE SHOWN FOR REFERENCE ONLY. REFER TO OWNERS FIXTURE DRAWINGS FOR FINAL LAYOUT. KEY NOTES (MARKET) 8 NOVEMBER 2010 1 PROVIDE 11/4'C HOMERUN FOR POWER WIRING. REFER TO THE REFRIG. EQUIPMENT SCHEDULE FOR CIRCUIT REQUIREMENTS. 2 PROVIDE VC IN CHASE FOR LV CABLE. PROVIDE CONDUIT FROM ACCESSIBLE CEILING SPACE TO STUB -OUT AT 88'.INSTALL CABLES TO TOP OF CASES. REFER TO SHEET R621 FOR REMS CABLES AND ROUTING. 3 ROUTE CONDUIT FROM ACCESSIBLE CEILING SPACE DOWN THROUGH CHASE. PROVIDE FLEXIBLE CONNECTION TO CASE WIREWAY FOR CASE LOADS. REFER TO SHEET A111 FOR EXACT LOCATION OF FALSE COLUMN CHASE. 4 PROVIDE 120V CONNECTION TO REFRIGERATION I/O PANEL MOUNTED ON TOP OF CASE. 5 POWER - 1'C HOMERUN TO ELECTRICAL PANEL. PROVIDE METAL CONDUIT STUB UPS AND FLEX CONNECTION TO CASES. PROVIDE FINAL CONNECTION FOR POWER. REFER TO EQUIPMENT SCHEDULE. 6 PROVIDE IT FROM BELOW REFRIGERATED CASE TO ACCESSIBLE CEILING SPACE FOR REMS CABLE. INSTALL REMS CABLE FROM EACH CASE TO REFRIGERATION CONTROL PANEL REMS -4. 7 COORDINATE VERTICAL PIPE DROPS OF PLUMBING. REFRIGERATION AND ELECTRICAL CONDUIT. ALL PIPING AND CONDUIT SHALL BE BUNDLED TIGHTLY TOGETHER TO MINIMIZE THE SIZE OF THE FALSE COLUMN PIPE ENCLOSURE. VERTICAL PIPE DROP LOCATION SHALL CORRESPOND WITH LOCATION FALSE COLUMN SHOWN ON ARCHITECTURAL PLANS. REFER TO ARCHITECTURAL FALSE COLUMN ENCLOSURE DETAIL. (A01B) (AO10) OWIZ DRY PRODUCE POWER & SYSTEMS PLAN 1/4" = 1' 4" MARKET AREA FREEZER/COOLER POWER & SYSTEMS PLAN v4" = V-0" Q z CD z 0 EVAP COIL I (COOLER) DOOR- HEATER DATE ISSUED ISSUES AND REVISIONS w 8 NOVEMBER 2010 11.8.10 - PERMIT SET POWER SYSTEMS PLAN DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 -NOV -2010 08:59 KEY NOTES (WALK -IN FREEZER/COOLER) A B 0 D 0 STUB 1/2 'C FROM LEAK INDICATOR ALARM (INSIDE & OUTSIDE WALK -IN COOLER /FREEZER) UP TO 4'ABOVE COOLER /FREEZER. INSTALL LOW VOLTAGE CABLE TO REFRIGERATION CONTROL PANEL ON TOP OF FREEZER. REFER TO SHEETS R421& R621. PROVIDE J -BOX @ 12' FOR LEAK TRANSDUCER. STUB 1/2 'C UP TO 4' ABOVE COOLER /FREEZER. INSTALL LOW VOLTAGE CABLE TO REFRIGERATION CONTROL PANEL ON TOP OF FREEZER. REFER TO SHEETS R421 & R621. PROVIDE CONNECTION TO FREEZER EVAP COIL THROUGH CONTACTOR FURNISHED IN REFRIGERATION CONTROL PANEL. PROVIDE 120V CONNECTION FROM REFRIGERATION CONTROL PANEL TO LIQUID LINE SOLENOID ON TOP COOLER & FREEZER. REFER TO SHEET R621. REFRIGERATION CONTROL PANEL MOUNTED IN VERTICAL POSITION ABOVE FREEZER /COOLER, FURNISHED BY REMS CONTRACTOR. INSTALL LOW VOLTAGE CABLES FROM PANEL TO WALK -IN FREEZER /COOLER. FINAL CONNECTIONS BY REMS CONTRACTOR. REFER TO SHEET R621 FOR REMS WIRING DETAILS. INSTALL HORN /STROBE DOOR SWITCH UNITS. FURNISHED BY REMS VENDOR, OUTSIDE OF FREEZER AND COOLER. STUB 1/2' C UP TO 4' ABOVE FREEZER. INSTALL LOW VOLTAGE CABLE TO REFRIGERATION CONTROL PANEL ON TOP OF FREEZER. REFER TO SHEETS R421 & R621. PROVIDE CONNECTION TO MEAT COOLER EVAP COIL THROUGH CONTACTOR FURNISHED IN REFRIGERATION CONTROL PANEL. GFCIBREAKER PROVIDED BY OWNER FOR HEAT TAPE CIRCUIT. PROVIDE 30 CD HORN /STROBE. CONNECT TO NEAREST FIRE ALARM HORN /STROBE EXISTING CIRCUIT. E -oc1coo REVIEWED FOR COMPLIANCE WITt NFPA70 a NEC DEC 21 2010 City of Tukwila RECEIVED NOV 19 2070 BUILDING DIVISION PERMITCENTER SHEET E401 T -0627 SOUTH CENTER, WA TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T062 7 VERSION R2 10 0 M o 8 08-06-10 TITLE MARKET AREA & PROJECT CODE 270627 CONFIGURATION LL POWER SYSTEMS PLAN SHEET E401 T -0627 SOUTH CENTER, WA VERTICAL SEALING FITTING AFTER WIRING WORK IS COMPLETE FILL SEALING FITTING WITH SILICONE CAULK. REFER TO SPEC SECTION 07 9200. INSULATION BY REFR. CONTRACTOR JUNCTION BOX CAULK PENETRATION BOTH SIDES OF PANEL W/ SILICONE CAULK REFER TO SPEC SECTION 07 9200 EMT CONDUIT NOTES: DO NOT USE SPRAY FOAM MATERIALS TO SEAL PENETRATIONS OR CONDUITS INSULATED PANEL CEILING DRILL HOLES NO MORE THAN 1/8' BIGGER THAN CONDUIT SIZE COOLER /FREEZER CONDUIT PENETRATION DETAIL NOT TO SCALE 6' MINIMUM CEILING NOTE: VERIFY LOCATIONS OF ALL COLUMN MOUNTED DEVICES WITH OWNERS SITE REPRESENTATIVE TO AVOID ANY ACCESSIBILITY CONFLICTS. MAXIMUM ALLOWABLE HOLE SIZE TO BE 1'. DRILL & INSTALL GROMMET & FD CAST JUNCTION BOX FOR FIRE ALARM REMOTE TEST STATION ON COLUMNS DRILL & INSTALL 4' X 4' J -BOX FOR NETWORK /DATA CABLES 4' X 4' J -BOX DRILL & INSTALL 4' X 4' J -BOX FOR THERMOSTAT WIRING 1/2' FLEXIBLE CONDUIT -HOLLOW SQ STEEL COLUMN DRILL & INSTALL GROMMET@ FOR RTU TEMP SENSOR E7 ON COLUMNS . LOCATIONS SHOWN ON MECHANICAL DRAWINGS. REFER TO SHALLOW CAST ALUM FS BOX W /STAINLESS STEEL COVER - PLATE FOR NEMA 5 -20R -GRAY RECEPTACLE OR DATA OUTLET COLUMN OUTLET DETAIL FLOOR v7 , w F z J D_w <z_ = J OLI_ wo Ln x(S 00 COL, LI-x 00 w,t 1-0 we 0z z 1— w iI 0 i;-) 10" TO CENTER OF BOX N- NOT TO SCALE CEILING FLEX CONDUIT FEED TO LIGHT FIXTURE, MOUNTED TO TOP OF FIXTURE BRACKET TYPE 'VV LIGHT FIXTURE FLEX CONDUIT FEED TO LIGHT FIXTURE, MOUNTED TO TOP OF FIXTURE BRACKET TYPE 'V2' LIGHT FIXTURE E2 FLOOR FOCAL LIGHTING SECTION LOCAL DOOR PANEL. BY ACCESS CONTROL CONTRACTOR. MOUNTED AT 12' -0" AFF ( ABOVE CEILING IF APPLICABLE.) CEILING LINE DETAIL NOTES: O SINGLE GANG. MUD RING, 4"x4" J -BOX ® PROVIDE MAGNETIC DOOR STATUS SWITCH. g PROVIDE CARD READER 48" AFF. L IRTEI J -BOX WITH SURFACE ACCESS COVER ONDUIT EMBEDDED IN WALL DOOR STATUS SWITCH (TYP) DOOR ELEVATION ACCESS CONTROL DETAIL 00 NOT TO SCALE TO LOCAL DOOR PANEL C WITH SURFACE ACCESS C99� ACCESCES S COVER r. CONDUIT EMBEDDED IN WALL n N DOOR STATUS SWITCH (TYP) LOCK DOWN BUTTON 54" AFF TO BE MOUNTED ABOVE LIGHT SWITCH (PUSH /PULL. HR DOOR ONLY) NOT TO SCALE LOCAL DOOR PANEL. BY ACCESS CONTROL CONTRACTOR, MOUNTED AT 12' -O" AFF ( ABOVE CEILING IF APPLICABLE.) 7 CEILING LINE IRTEI n e 1, c e n n u CARD READER / J-BOX 1 1e n , n e n n u e n n R ?rES - DETAIL NOTES: O SINGLE GANG, MUD RING. 4"x4" J -BOX ® PROVIDE MAGNETIC DOOR STATUS SWITCH. ® PROVIDE CARD READER 48" AFF. DOOR ELEVATION ACCESS CONTROL DETAIL LOCK DOWN BUTTON (HR DOOR ONLY) s nn 0 DEVICE WIRING TAI c i TO LOCAL PANEL DEVICE WIRING DETAIL 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 NOT TO SCALE TYPE FD BOX WITH WEATHER- PROOF COVERPLATE AND DEVICE LIQUIDTIGHT FLEXIBLE CONDUIT TO EQUIPMENT OR RECEPTACLE RIGID GALV STEEL CONDUIT TI: STUB (TYP) •✓ RIGID GALV STEEL COUPLING •' `�' `'•'�- - • I' ' • FLUSH WITH FLOOR (TYP) • a � ` `' ` • ° 1/416 VC COATED RIGID GALV STEEL CONDUIT (TYP) �� ' ` PVC HARGIS Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T: \Remodels \0627 WA South Center R\ ActiveCAD 0627e511.dcln CONDUIT AS REQUIRED CONDUIT STUBS AND DEVICE BOX FREE STANDING MAC JUNCTION BOX NOT TO SCALE POWER & DATA CABLE ROUTED THROUGH POWER POLE TO JUNCTION BOX ABOVE CEILING SECURE POWER POLE TO TOP OF MAC PRICE SCANNER MAC PHONE GONDOLA GONDOLA BASE DECK CEILING GONDOLA MAC MINI ASSISTANCE CENTER (MAC) DETAIL NOT TO SCALE CONNECTOR BRACKET FURNISHED BY FIXTURE VENDOR MAKE CONNECTION TO LIGHTING FIXTURE ROUTE MC CABLE VIA FIXTURE CHANNEL LOCATE POWER POLE PER PLANS INSTALL POWER POLE MOUNTING BRACKET FURNISHED WITH POWER POLE PRICE SCANNER FLUORESCENT VALANCE LIGHTING FURNISHED AND INSTALLED BY FIXTURE VENDOR GREETING CARDS FIXTURE DETAIL Fz NOT TO SCALE 159' WALL HEIGHT - 6' TYPE V1 VALANCE LIGHT 114' WALL HEIGHT - 4' TYPE V2 VALANCE LIGHT POWER POLE FLEXIBLE CONDUIT TO EQUIPMENT OR RECEPTACLE 4' X 4' X 2 1/8' JUNCTION BOX (TYPICAL) WITH COVERPLATE 1 Y8', IN LENGTH, RIGID GALV STEEL CHASE NIPPLE STUB (TYP) ANCHOR JUNCTION BOX TO FLOOR WITH CONCRETE ANCHORS (TYP) f— FLEXIBLE CONDUIT TO 11111E°11�"�`��`� EQUIPMENT OR RECEPTACLE • PROVIDE SHIM AS jtI:;,1: _�'' ■S REQUIRED •. ° RIGID GALV STEEL COUPLING N NI EXTEND COUPLING I /2' AFF I` . ` CONDUIT AS REQUIRED PVC COATED RIGID GALV STEEL CONDUIT (TYP) FLOOR OUTLET TYPE 'A' LOCAL DOOR PANEL, BY ACCESS CONTROL CONTRACTOR, MOUNTED AT 12' -O" AFF ( ABOVE CEILING IF APPLICABLE.) J -BOX WITH SURFACE ACCESS COVER DOOR ELEVATION ACCESS CONTROL DETAIL NOT TO SCALE CEILING LINE CONDUIT EMBEDDED IN WALL CARD READER/ J -BOX 1 3 DETAIL NOTES: 1 GANG, MUD RING, 4 "x4" SQUARE BOX. PROVIDE MAGNETIC DOOR STATUS SWITCH. PROVIDE CARD READER 48" AFF. VERIFY LOCATION AND KEYED LOCKSET WITH HARDWARE SUPPLIER Atti COOLER /FREEZER INSULATED CEILING PANEL SEAL PENETRATION WITH SILICONE CAULK. REFER TO SPEC SECTION 07 9200 FOR MATERIAL SPECIFICATION A 1.11 AIM FRONT VIEW 4P 11 4111.14. POWER FEED FOR--/ LIGHT FIXTURE SIDE VIEW PROVIDE CONDUITS FOR LOW VOLTAGE (FA & EMS) CABLES. EXTEND CONDUITS A MINIMUM OF 18' ABOVE THE BOTTOM OF THE CONTROL CABINET. BUSH & SUPPORT CONDUITS. ROUTE FEEDER CONDUIT TO J -BOX ENCLOSING THE UNIT DISCONNECT (CIRCUIT BREAKER). PROVIDE GROUND WIRE TO J -BOX. ALL CONNECTIONS SHALL BE LIQUID TIGHT. USE KNOCKOUTS PROVIDED. NO OTHER PENETRATIONS ALLOWED. SEAL ALL UNUSED OPENINGS WITH EPCO DUCTSEAL COMPOUND. RTU WIRING LIQUIDTIGHT FITTING LIQUIDTIGHT CONDUIT • • ■ MC FITTING COUPLING LIQUID TIGHT FITTING DETAIL TO LOCAL SECURITY PANEL DEVICE WIRING DETAIL MOUNT BRACKET TO PANEL UTILIZING HILT) KWIK -PRO 812 -14 HWH SELF - DRILLING TWO (2) SCREW, 3/4' IN LENGTH WITH ZINC COATED FINISH OR EQUAL LIGHT FIXTURE MOUNTING BRACKET LIGHT FIXTURE MOUNTING BRACKET BRACKET SPACING REQUIRED: 4' HOUSING - 36' BETWEEN BRACKETS 8' HOUSING - 49' BETWEEN BRACKETS NOTES: LOCATE COOLER /FREEZER LIGHT FIXTURE NO CLOSER THAN 1' -O' FROM AIR FLOW EVAPORATOR POWER FEED TO COOLER /FREEZER LIGHT FIXTURE SHOULD ONLY PENETRATE COOLER /FREEZER ONCE AND BE CONNECTED AT END OF LIGHT FIXTURE. COOLER/FREEZER LIGHT FIXTURE MOUNTING DETAIL NOT TO SCALE CEILING I ROUTE 3 /8' MC CABLE FROM J -BOX UNDER BASE DECK THROUGH STORE FIXTURE TO VALANCE LIGHT, TYPICAL ROUTE MC CABLE THROUGH BASE DECK TO EACH J -BOX TYPICAL HARDLINES VALANCE LIGHTING WIRING DETAIL NEUTRAL NOT TO SCALE WHT HOT BLK RED 11PP CKRT RED 0 w J 07 J OD CONTROL OUTPUT LOAD COMMON +24VDC • ANY 24VDC • CLG/ WALL I ,SENSOR, LOW VOLTAGE WIRING DIAGRAM FOR SINGLE MOTION SENSOR NOT TO SCALE MOUNT J -BOX UNDER BASE DECK, TYPICAL RTCR (CONDENSER) CONTROL PANEL FURNISHED W /UNIT REFR (CONDENSER) LOW VOLTAGE JUNCTION BOX FURNISHED W/ UNIT LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT FLOOR VALANCE LIGHT 0 GYP BD NOT TO SCALE ELECTRICAL JUNCTION BOX NOTE: VERIFY LOCATION OF VALANCE WITH ELECTRICAL & OWNER'S FIXTURE PLAN FOCAL LIGHTING VALANCE ROUTE POWER CORD FOR GONDOLA DISPLAY THROUGH HOLES TO RECEPTACLE LOCATED UNDERNEATH BASE DECK. I DRILL 2' HOLE IN BASE DECK, '. PROVIDE BUSHING GONDOLA r IGONDOLA BASE DECK RECEPTACLE POWER ROUTED UNDER BASE DECK TO POWER POLE UP TO JUNCTION BOX ABOVE CEILING. 1/2' FLEX CONNECTION TO LIGHT FIXTURE SURFACE MOUNTED RECEPTACLE ©® POWER JUNCTION BOX FURNISHED W/ UNIT MAINTENANCE RCPT PROVIDED BY EC COMM LOOP COMM LOOP CONNECTION POINT COMM LOOP CONTINUATION LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT RTCR (COMPESSOR) CONTROL PANEL FURNISHED W /UNIT RTCR TYPICAL CONDUIT DIAGRAM POWER PACK HIGH VOLTAGE (277V OR 120V) CONNECTION MADE INSIDE BOX POWER PACK NOTES: A. POWER PACK SHOULD NOT BE MOUNTED WITHIN FOUR FEET OF THE SENSOR B. ALL SWITCHES ARE LOCATED ON THE LOAD SIDE OF THE POWER PACK NOT TO SCALE FRONT VIEW 6 1/2 "J j NOT TO SCALE SURFACE MOUNTED RECEPTACLE SIDE VIEW VIDEO GAMES INTERACTIVE DISPLAY — RECEPTACLE MOUNTING DETAIL NOT TO SCALE REFER TO SPECIFICATION SECTION 27 9900 FOR TYPICAL DETAILS 20 THRU 31 3/4'C FOR MAINTENANCE RECEPTACLE CONNECTION VC FOR POWER CONNECTION 3/4'C FOR COMM LOOP 3/4'C FOR LOW VOLTAGE SENSORS MOUNT CONDUIT ON PIPE SUPPORT PROVIDED BY OTHERS. REFER TO R511 LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH LOW VOLTAGE JUNCTION BOX FURNISHED W/ UNIT RTCR (COMPRESSOR) GROMMET ALL SHEET METAL OPENINGS WHERE LIQUID TIGHT IS USED COMM LOOP COMM LOOP CONNECTION POINT LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT NOT TO SCALE DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 08-06-10 8 NOVEMBER 2010 1 C C i C 0 El . OIE1 1os, DOOR STATUS SWITCH (TYP) DOOR ELEVATION ACCESS CONTROL DETAIL NOT TO SCALE CEILING LINE CONDUIT EMBEDDED IN WALL CARD READER/ J -BOX 1 3 DETAIL NOTES: 1 GANG, MUD RING, 4 "x4" SQUARE BOX. PROVIDE MAGNETIC DOOR STATUS SWITCH. PROVIDE CARD READER 48" AFF. VERIFY LOCATION AND KEYED LOCKSET WITH HARDWARE SUPPLIER Atti COOLER /FREEZER INSULATED CEILING PANEL SEAL PENETRATION WITH SILICONE CAULK. REFER TO SPEC SECTION 07 9200 FOR MATERIAL SPECIFICATION A 1.11 AIM FRONT VIEW 4P 11 4111.14. POWER FEED FOR--/ LIGHT FIXTURE SIDE VIEW PROVIDE CONDUITS FOR LOW VOLTAGE (FA & EMS) CABLES. EXTEND CONDUITS A MINIMUM OF 18' ABOVE THE BOTTOM OF THE CONTROL CABINET. BUSH & SUPPORT CONDUITS. ROUTE FEEDER CONDUIT TO J -BOX ENCLOSING THE UNIT DISCONNECT (CIRCUIT BREAKER). PROVIDE GROUND WIRE TO J -BOX. ALL CONNECTIONS SHALL BE LIQUID TIGHT. USE KNOCKOUTS PROVIDED. NO OTHER PENETRATIONS ALLOWED. SEAL ALL UNUSED OPENINGS WITH EPCO DUCTSEAL COMPOUND. RTU WIRING LIQUIDTIGHT FITTING LIQUIDTIGHT CONDUIT • • ■ MC FITTING COUPLING LIQUID TIGHT FITTING DETAIL TO LOCAL SECURITY PANEL DEVICE WIRING DETAIL MOUNT BRACKET TO PANEL UTILIZING HILT) KWIK -PRO 812 -14 HWH SELF - DRILLING TWO (2) SCREW, 3/4' IN LENGTH WITH ZINC COATED FINISH OR EQUAL LIGHT FIXTURE MOUNTING BRACKET LIGHT FIXTURE MOUNTING BRACKET BRACKET SPACING REQUIRED: 4' HOUSING - 36' BETWEEN BRACKETS 8' HOUSING - 49' BETWEEN BRACKETS NOTES: LOCATE COOLER /FREEZER LIGHT FIXTURE NO CLOSER THAN 1' -O' FROM AIR FLOW EVAPORATOR POWER FEED TO COOLER /FREEZER LIGHT FIXTURE SHOULD ONLY PENETRATE COOLER /FREEZER ONCE AND BE CONNECTED AT END OF LIGHT FIXTURE. COOLER/FREEZER LIGHT FIXTURE MOUNTING DETAIL NOT TO SCALE CEILING I ROUTE 3 /8' MC CABLE FROM J -BOX UNDER BASE DECK THROUGH STORE FIXTURE TO VALANCE LIGHT, TYPICAL ROUTE MC CABLE THROUGH BASE DECK TO EACH J -BOX TYPICAL HARDLINES VALANCE LIGHTING WIRING DETAIL NEUTRAL NOT TO SCALE WHT HOT BLK RED 11PP CKRT RED 0 w J 07 J OD CONTROL OUTPUT LOAD COMMON +24VDC • ANY 24VDC • CLG/ WALL I ,SENSOR, LOW VOLTAGE WIRING DIAGRAM FOR SINGLE MOTION SENSOR NOT TO SCALE MOUNT J -BOX UNDER BASE DECK, TYPICAL RTCR (CONDENSER) CONTROL PANEL FURNISHED W /UNIT REFR (CONDENSER) LOW VOLTAGE JUNCTION BOX FURNISHED W/ UNIT LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT FLOOR VALANCE LIGHT 0 GYP BD NOT TO SCALE ELECTRICAL JUNCTION BOX NOTE: VERIFY LOCATION OF VALANCE WITH ELECTRICAL & OWNER'S FIXTURE PLAN FOCAL LIGHTING VALANCE ROUTE POWER CORD FOR GONDOLA DISPLAY THROUGH HOLES TO RECEPTACLE LOCATED UNDERNEATH BASE DECK. I DRILL 2' HOLE IN BASE DECK, '. PROVIDE BUSHING GONDOLA r IGONDOLA BASE DECK RECEPTACLE POWER ROUTED UNDER BASE DECK TO POWER POLE UP TO JUNCTION BOX ABOVE CEILING. 1/2' FLEX CONNECTION TO LIGHT FIXTURE SURFACE MOUNTED RECEPTACLE ©® POWER JUNCTION BOX FURNISHED W/ UNIT MAINTENANCE RCPT PROVIDED BY EC COMM LOOP COMM LOOP CONNECTION POINT COMM LOOP CONTINUATION LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT RTCR (COMPESSOR) CONTROL PANEL FURNISHED W /UNIT RTCR TYPICAL CONDUIT DIAGRAM POWER PACK HIGH VOLTAGE (277V OR 120V) CONNECTION MADE INSIDE BOX POWER PACK NOTES: A. POWER PACK SHOULD NOT BE MOUNTED WITHIN FOUR FEET OF THE SENSOR B. ALL SWITCHES ARE LOCATED ON THE LOAD SIDE OF THE POWER PACK NOT TO SCALE FRONT VIEW 6 1/2 "J j NOT TO SCALE SURFACE MOUNTED RECEPTACLE SIDE VIEW VIDEO GAMES INTERACTIVE DISPLAY — RECEPTACLE MOUNTING DETAIL NOT TO SCALE REFER TO SPECIFICATION SECTION 27 9900 FOR TYPICAL DETAILS 20 THRU 31 3/4'C FOR MAINTENANCE RECEPTACLE CONNECTION VC FOR POWER CONNECTION 3/4'C FOR COMM LOOP 3/4'C FOR LOW VOLTAGE SENSORS MOUNT CONDUIT ON PIPE SUPPORT PROVIDED BY OTHERS. REFER TO R511 LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH LOW VOLTAGE JUNCTION BOX FURNISHED W/ UNIT RTCR (COMPRESSOR) GROMMET ALL SHEET METAL OPENINGS WHERE LIQUID TIGHT IS USED COMM LOOP COMM LOOP CONNECTION POINT LIQUID TIGHT CONDUIT 6' -0' MAX CONDUIT LENGTH IMC CONDUIT NOT TO SCALE DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 08-06-10 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 —NOV -2010 08:27 IMC UNDER BASE DECK RECEPTACLE DETAIL 1/40NDOLA BASE DECK 0 TYPE 'V2' LIGHT FIXTURE JUNCTION BOX AND FLEX CONDUIT FEED TYPE 'V2' LIGHT FIXTURE 0 NOT TO SCALE 4--- TYPE 'V1' LIGHT FIXTURE 0 JUNCTION BOX AND FLEX CONDUIT FEED TYPE 'V1' LIGHT FIXTURE E2 FOCAL LIGHTING ELEVATION NOT TO S MOUNT RECEPTACLE AND DATA OUTLET TO BASE RAIL OF FIXTURE. FIXTURE RAIL DRILL 2' HOLE IN BASE DECK, PROVIDE BUSHING MAINTAIN 3 1/2' OF CLEARANCE FROM BACK OF FIXTURE RAIL WHEN INSTALLING BASE DECK SPLIT TER BOARD NOTE: MOUNT BASE DECK RECEPTACLE TO FIXTURE RAIL WITH 1/4 ' X 1' PANHEAD SHEET METAL SCREWS. PRE -DRILL FIXTURE RAIL AS REQUIRED LEARNING CENTER INTERACTIVE DISPLAY RECEPTACLE & DATA MOUNTING DETAIL NOT TO IMC PIPE BOX CU CU TYPICAL CONDUIT DIAGRAM SIDEVIEW LIQUID TIGHT IF CONDUIT LENGTH BETWEEN CU & PIPING BOX IS LESS THEN 6' -0', THEN LIQUID TIGHT IS ACCEPTABLE, OTHERWISE USE IMC LIQUID TIGHT GROMMET ALL SHEET METAL OPENINGS WHERE LIQUID TIGHT IS USED NOT TO SCALE JUNCTION BOX (INSIDE OF WALL) DIP SWITCHES PW -100 UW -100 PIR LENS NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF WALL MOUNTED MOTION SENSORS. 35 WALL MOUNTED MOTION SENSOR DETAIL FOR TYPES PW -100 & UW -100 NOT TO SCALE SCALE GONDOLA MOUNT RECEPTACLE AND DATA OULET UNDER BASE DECK TO FIXTURE RAIL ARM CEILING 3' MUDRING HOLE CEILING ATTACHMENT RIN OCCUPANCY SENSOR OCCUPANCY SENSOR MOUNTING SCREW, X2 OCCUPANCY COVER NOTE: REFER TO LIGHTING DRAWINGS FOR LOCATION OF CEILING MOUNTED MOTION SENSORS. 32 CI -205 -1 MOTION SENSOR CEILING MOUNTED NOT TO SCALE REVIEWED FOR COMPLIANCE WITH NFPA70 NEC DEC 2 2010 City ofTuj ila BUILDING LINE GROUND "EU0 01(00 BLACK GREEN /YELLOW NEUTRAL GROUND GREEN 1 120V/230V/277V GROUND LOAD RED J 0 RECEIVED NOV 19 2010 PERMIT CENTER LINE VOLTAGE WIRING DIAGRAM FOR MOTION SENSOR TYPE PW -100 NOT TO SCALE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE TO627 VERSION MR201008 08-06-10 TITLE ELECTRICAL DETAILS & PROJECT CODE 270627 CONFIGURATION LL DIAGRAMS SHEET E511 T -0627 SOUTH CENTER, WA • 00.1d 129 ' > ksFEED k.::>1S P E IS .225.4 BUS MLO DESCRIPTION LOAD LOAD BREAKER KVA QTY TYPE AMP/ POLE BREAKER LOAD LOAD AMP/ POLE TYPE QTY KVA DESCRIPTION S FCKR..I'OM LIGHTING STOCKROOM LIL:H1 /1 mss` STOCICROOM LIGHTING SPACE V -17-5 VA VAV -17-6 VAV -17 -7 VAV -17-8 VAV -17 -9 SPECIALTY .• r;... ' L I .3: z:` :f : 4•? SPECIALTY LIGHTING SPECIALTY LIGHTING >.., . ...,,...S :VALANCE TG. SOFT LIN ES VALANCE Tt €:. 1 873 '. >{ LX,M LIGHTING STOCKROOM /B? r.1O.r3' LIGH t IN STOCKROOM l.ik H r• %;`S <.B (23) s, 241 .�5, k :r 2 2.5 2.5 7.5 1.5 £.4 18 1.6 2.6 0 :9 I. ,1 L .2071 SC L ✓O PW 20/1 PW 20/1 PW 201 PW 40/1 PW 9. >^ 20 L }{/ L 297f I i3ifi >1 L 4:0lY 20YI 20./I L .29/1 2w1 .1 C U E 11 C P .sir C fM 8 3 C ,f5 F3£ 29 C .A 33 1s 35 C 37 A ti 4 xI C 4 Lx 'fx 20 wFw: 24 23 _ 4 ,F 20 29/1 20/1 20/1 20/1 20/1 20/1 40/1 20/1 SC�»t (3 Ye MN Si PW L L L L L L, PW PW PW PW (1/;? 3'7 a x . 13; f F. 'Y 4 MAR MARKING 3 331 1 MT:N,4i`.'� 3.Y'•'S L, G S': HG .MAR i:> 1.=0}"1 /7NG .,. 5.4 r K -a. aft LION TING 66 PERGOLA 3.8 COMPACTOR 3.3 fi SPARE - 1 VAV-17-10 • 1.5 FREEZER /COOLER LIGHTING 0.6 FOCAL VALANCE LIGHTING 0.5 FOCAL VALANCE LIGHTING 1.1 INVESTIGATION CTR LTG 1 INVESTIGATION CTR LTG 1.2 INVESTIGATION CTR LTG 1 VAV -17 -1 1 7.5 1.5 VAV -17-2 VAV -17-3 VAV -17-4 2-0627 ,,10 Demand Load Phase A Phase B Phase C Total Average *Spares not included KVA AMPS 28.9 402 41.4 110.5 104.4 145.4 149.5 133.0 Type KVA L 56.9 R 0.0 PN 0.0 PW 28.0 MN 0.0 MNI 11.4 MS 0.0 MW 0.0 KT 0.0 Total 96.3 Factor KVA x 1.25 x0.5= x1= x1= x1= x1= x1= x1= x 0.65 71.1 0.0 0.0 28.0 0.0 11.4 0.0 0.0 0.0 110.5 100 %offs 96.3 1105 133.0 Okva, plus 50% of remainder. Total Connected KVA Total Demand KVA Total Demand Amps FEED TINGf 2254 BUS .2304 MCB Si.JPRLIED FR wi.'i: 42 DESCRIPTION LOAD LOAD BREAKER KVA QTY TYPE AMP/ POLE # BREAKER LOAD LOAD AMP/ POLE TYPE QTY KVA DESCRIPTION SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SUA,07 PUMP //3.1 /. „EMS-PC SPAR E SPAR „. SPARE ZRf.: SPAR E R O OF .8.0t1.1P R 2 C.r .. SPARE STAR t„ SPARE SPAR E. SPARE SR SR SR SR SR SR SR SR SR SR 11.6 f. :•F RN SR SR 0,4 (2) R SR SR .20r'r 20'`1 .2011 204 2871 .:2071 20/1 .:.V,I 23 /I .V t1 I .28/1 ^x74 20/1 .:_£I /2 .2/I /I 2W1 011 I .4 5 0 C B 7 F? 8 i B Ft ?? 11 C ?t: 13 A 14 B '6 1 a. 1 t _: A. S 22 ."2.3 C z y ....c C /0 32 31 33 ., .1 {,: 36 37 A ;3sr: ..?3 S -;0 41 C ,� 20:: SR .231 S;' e' 20/1 • m 200 t. 2.0/ sA' 26> SR , >. >•3 SR SR SR SR SR SR SR: .2/.31 . SR SR F`. SR xr ..SPA. RE .SPARE SPARE SPARE SPARE SPARE SPARE .SFAR Y SPARE SPA RE SPARE SPA .R SPAR SPARE SPARE T-0621 11/0 Demand Load Phase A Phase B Phase C Tata I Average *Spares not included KVA AMPS 04 1.6 0 -0 2.0 3 -3 13.3 0.0 5.6 Type 10A L 0.0 R 0.4 PN 1.6 PW 0.0 MN 0.4 MNI 0.0 MS 0.0 MW 0.0 KT 0.0 Total 2.0 Factor KVA x 1.25 0.0 x 0.5 = 0.4 *100% of 1st lokva, plus 50% of remainder. x1= 1.6 x 1 = 0 -0 x 1 = 0.0 x1= 0.0 x 1 = 0.0 x 1 = 0.0 2.0 Total Connected KVA x 0.65 0.0 2.0 Total Demand KVA 2.0 5.6 Total Demand Amps LP -14 NEW ROOM 146 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 RMS 120/208 VOLT, 3 PHASE, 4 WIRE, WITH GROUND BUS 100A BUS 100A MCB SUPPLIED FROM T -14 EQUIP WITH 100 AMP, 3 POLE CONTACTOR ON MAIN BUS DESCRIPTION LOAD LOAD BREAKER BREAKER LOAD LOAD # AMP/ POLE TYPE QTY KVA KVA QTY TYPE AMP/ POLE # DESCRIPT ION TV TRAC RCPT TV TRAC RCPT TV TRAC RCPT TV TRAC RCPT TV TRAC RCPT TV TRAC RCPT DISPLAY POWER POLE DISPLAY POWER POLE DISPLAY FLOOR BOX DISPLAY FLOOR BOX DISPLAY FLOOR BOX SPARE BOOM BOX BOOM BOX P/S BOOM BOX PIS SPARE SPAR E SPARE DISPLAY FLOOR BOX SPARE SPARE 1.4 (1) R 1.4 (1) R 1.4 (1) R 1.4 (1) R 1.4 (1) R 1.4 (1) R 1.3 (7) R 1.3 (7) R 1.3 (7) R 1.1 (6) R 1.1 (6) R SR 0.4 (2) R 0.6 (1) R 0.6 (1) R O SR SR SR 1 (5) R O SR O SR 20/I ** 20/1 ** 2011 ** 2011 ** 2011 ** 20/1""" 20/1 20/1 2011 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 A B C A B C A B C A B C A B C A B C A B C 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 20 /1 ** 20/1** 20//1 *` 20/1 ** 20/1** 20/1** 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 R R R R R R SR R R SR R R SR R R R R R R R R 1.4 TVTRACRCPT 1.4 TV TRAC RCPT 1.4 TV TRACRCPT i_4 TVTRACRCPT 1.4 TV TRAC RCPT 1.4 TVTRACRCPT SPARE 0.2 DISPLAY POWER POLE 02 DISPLAY POWER POLE 0 SPARE 1.3 DISPLAY POWER POLE 1.3 DISPLAY POWER POLE 0 0.2 0.4 SPARE BOOM BOX RCPT BOOM BOX RCPT 0.4 DISPLAY POWER POLE 02 MMB LCD MONITORS 0.2 MMB LCD MONITORS 0.2 SERVICE COUNTER 0.2 SERVICE COUNTER 1.1 SERVICE COUNTER Demand Load KVA AMPS Phase A Phase B Phase C Tota l Average *Spares not included 6.6 7.1 7.1 20.7 54.9 58-8 58.8 57.5 Type K'VA Factor KVA L 0.0 x 1.25 R 31.4 x0.5= PN 0.0 x1= PW 0.0 x1= MN 0.0 x1= MNI 0.0 x1= MS 0.0 x1= MW 0.0 x1= KT 0.0 x0.65 Total 31.4 0.0 20.7 900% of 1st 1 Okva, plus 50% of remainder. 0.0 0.0 0.0 0.0 0.0 0.0 31.4 Total Connected KVA 0.0 20.7 Total Demand KVA 20.7 57.5 Total Demand Amps T-0621 00,0,0 O 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 H A R G I S ■ ■ Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargIS.biz -r n_____I_I- \('Lr17 \A/A c.,, +4, Ce., +,tr P\ Ar +IviCAf \nA77Pfi01.clan R. -- z - ,. _ : M t RwYOC .acsE(75 MO UN ThVG S. r Ft. w._...... vol.. L.Y-• .. 5;:::: s 1;7. e. ,.... i,:v<E G-Y 4:�.: _� `7 t . ..,, _. >: t,: ,. , It :;20/26V irc:v: 0., ,; r i,:.,. . 4 . r'. `'f i::,: WOW :GR.OUNO SUS OFFICE 212 &213 RECEPT DESCRIPTION KVA LOAD' QTY LOAD BREAKER TYPE AMP/ POLE # BREAKER LOAD BREAKER LOAD # AMP / POLE TYPE LOAD QTY DESCRIPTION KVA KVA QTY TYPE AMP/ POLE lea;. ' -z=-- >. # .,.sT - ,` ; KVA • REFR CTRL PNL -SALES FLOOR PW 20r;3 IC 210 RECEPT A 2 20' ., . / ,2 OFFICE ; (1) PN 30/1 3 8 4 20/1 PN (2) 1.4 ABO4 ABO5 D/T 131=Z&FRM HTR IREFR CTRL PNL - RTCR -2 2.5 PW 5 C 8 0 4 20/1 SPARE 124 4:4 OF l F( CE 11 TG 7 A := 20/1 SR () 0.0 SPARE SPARE 0 SR 20/1 y': c r .w ^. C ; • ,. 0 1 . } 0 : L - 9 4_4 OFFICE 1.. > 0. C 12 20)1 SR a, � - . . / $ l° Y f ^i ¢ 0 . .Z :Lr!y. ? 2011 SR 0 8 ti/ F ... (31 r : lFA Y:Y S :.. 7G .5 1S 2011 SR 0 0.0 SPARE SPARE 0 SR 20/1 ;7 C 15 20/1 SR () 0.0 SPARE SPARE 0 "F 19 SPAR E 20/1 SR 0 0.0 SPARE SPARE 0 SR 20/1 F.:. S .22 p.m () F ^ Cr: 12 . 0/1 SR C .24 0 SPARE () 0.0 SPARE F",._., - - >- 1 () R 20/1 z: TING 1 2011 SR I. 20/1 ,^ A 14 .20 Nxt 1) 0.3 $13-37 0.0 SPARE SPARE z °= _mot rR C 3:9 20/1 SR 0 SPACE 1.5 SC ? A ,:tF t?r 0 0.0 SPARE SPACE C 30 SC 33 B 34 SR U 0.0 SPARE SPACE 201 17 C :f.3 SR rW 0.0 SPARE SPACE (1) SC >'£ -- = FS..H1.1.2) SR :.. 7 (1) P3,1 30/3 . 19 A 2: :20/1 S? 0.0 SPARE 5 SPARE R (3) SC 41' C 42 SR 0 0.0 SPARE PN KVA 31 S 23 291 SR KVA . 9 SPARE . -06,7 me Phase A 1.9 16.2 L 0.3 :F. ) O.4 PN 20/1 ,,3 t : •F %� : 1.0 > k �1 �.w PHARMACY Y � #)i '� -: "Fn t a t,„-I?( PN 7.6 „ 7 -6 FL G4:'1 27 G w„ 20/1 y (. ) 4,4 K11:1-4 x 125 0.0 _ ce 'r : -?> 0.0 SPARE 24.8 E 0.0 se? , �, f '. C 30 ..7:y -t »C MNI R_ i SPARE x 1 = 00 SF= _- , ... 0.3 41 ,. MS SR 3:1/3 31 A 32 25/1 SR 0 SPARE 02 x 1 = 00 8.9 Total Connected KVA 0.0 f;. 0.0 SR 0.0 33 L 34 29 SR 0.0 0 SPARE Total 8.9 Phase B 8.9 24.8 Total Demand Amps R MS SR x1= 33 C V 3 . L (5) 0.3 FOCAL VALANCE LIHTING PN f_--, RE x 1= 0.0 .. Total Connected KVA 55 3073 37 A 30 201 I. (5) 03 FOCAL VALANCE LIGHTING Total Demand KVA Average 102.0 Total F 0.0 3f S Total Demand Amps >w <?T >> :r^y'>9"::.L *Spares not included MNI 0.0 MNI x 1 = 0.0 SR 0.0 `J.R C 42 291 i. 1) >.. w. N -1 MS x1 = 0.0 x 1 = 0.0 MW 02 MW x 1 = 0.0 x 1 = 34.5 Total Connected KVA T-0627 T-0627 as Total Connected KVA Demand Load KVA AMP'S x0.65 Type KVA 36.7 Factor KVA Total Demand KVA Total 34.5 Total 56.4 36.7 Phase A 9.8 3v_5 156.4 L 15.5 x 1.25 19.4 Phase B 13.9 5.O R 1.0 x 0.5 = 1.0 *140% of 1st 10kva, plus 50% of remaind+e *_ Phase C 12.2 4-#-_0 PN 11.0 x 1 = 11.0 Total 35.9 PW 3A x 1 = 3.0 Average 4-....2 MN 0.0 x 1 = 0.4 *Spares not Included MM 0.0 x 1 = 0.0 MS 0.0 x 1 = 00 MW 1.5 x 1 = 1.5 32.0 Total Connected KVA KT 0.0 x0.65 00 35.9 Total Demand KVA Total 32.0 35.9 43.2 Total Demand Amps f =` -I - i.$$. E:x;,s ...4. . ' 4' :i . DESCRIPTION KVA EXISTING PANEL LP -4, RE -LABEL AS LP -.12A _� `7 t . ..,, _. >: t,: ,. , It :;20/26V irc:v: 0., ,; r i,:.,. . 4 . r'. `'f i::,: WOW :GR.OUNO SUS OFFICE 212 &213 RECEPT DESCRIPTION (4) LOAD LOAD BREAKER 20/1 1 BREAKER LOAD LOAD DESCRIPT1 ?.4 0.7 DISTRIC OFFICE 200 RECEPT KVA QTY TYPE AMP/ POLE Il # AMP /POLE TYPE QTY KVA • REFR CTRL PNL -SALES FLOOR 0.4 (2:) PN 20/1 IC 210 RECEPT A .2 20/1 PN (3) 0.5 ABO1 ABO2 ABO3 €I1 /T DR H TR Ft EFR CTRL PNL - RTCR -1 2.5 (1) PN 30/1 3 8 4 20/1 PN (2) 1.4 ABO4 ABO5 D/T 131=Z&FRM HTR IREFR CTRL PNL - RTCR -2 2.5 (1) PN 3011 5 C 8 20/1 SR () 0.0 SPARE SPARE 0 SR 20/1 7 A := 20/1 SR () 0.0 SPARE SPARE 0 SR 20/1 :r :> 10 2011 SR 0 0.0 SPARE SPARE 0 SR 20/1 11 C 12 20)1 SR 0 0.0 SPARE SPARE 0 SR 20/1 13 A 14 2011 SR 0 0.0 SPARE SPARE 0 SR 20/1 / .5 1S 2011 SR 0 0.0 SPARE SPARE 0 SR 20/1 ;7 C 15 20/1 SR () 0.0 SPARE SPARE 0 SR 20/1 19 A .2C 20/1 SR 0 0.0 SPARE SPARE 0 SR 20/1 21 S .22 20/1 SR () 0.0 SPARE REMS -1 CONTROL PANEL 0.2 (1) PN 20/13 R (1) C .24 2011 SR () 0.0 SPARE ROOF RECEPTACLE 1 () R 20/1 25 A 2 2011 SR 0 0.0 SPARE MARKET DOWNLIGHTS 0.3 (5) L 20/1 .2} B 2011 SR () 0.0 SPARE SPARE 0 SR 20/1 29 C 3:9 20/1 SR 0 0.0 SPARE SPACE R (4) SC 31 A ,:tF SR 0 0.0 SPARE SPACE C 30 SC 33 B 34 SR U 0.0 SPARE SPACE 2011 SC 35 . 33 SR 0 0.0 SPARE SPACE (1) SC 37 A 8 SR 0 0.0 SPARE SPACE IC 210 TV SC 39 5 k SR () 0.0 SPARE SPACE R (3) SC 41' C 42 SR 0 0.0 SPARE Demand Load KVA A_IAAPS Type KVA Factor KVA (2) . -06,7 me Phase A 1.9 16.2 L 0.3 x 1.25 O.4 0 20/1 Phase B 4.3 35.8 R 1.0 x 0.5 = 1.0 *100% of 1st l0kva, plus 50% of rema €rtarier_ Phase C 2.7 22.5 PN 7.6 x 1 = 7 -6 KVA A08 FRZR FANS Total 8.9 5.4 PW 0.0 x 1 = 0.4 x 125 0.0 Average 0.0 SPARE 24.8 MN 0.0 x 1 = 0.0 20.6 x 0.5 = *Spares not included *100% of 1st 10kva, plus 50% of rerna inder. Phase C MNI 0.0 x 1 = 00 0.3 x 1 = 0.3 41 C MS 0.0 x 1 = 0.0 PW 0.0 x 1 = 0.0 MW 02 x 1 = 00 8.9 Total Connected KVA 0.0 x 1= 0.0 KT 0.0 x 0.65 0.0 8.9 Total Demand KVA MNI 0.0 x 1= Total 8.9 Phase B 8.9 24.8 Total Demand Amps LP -15 NEW REAR EDC SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER)- 10,000 RMS 1201208 VOLT, 3 PHASE, 4 WIRE, WITH GROUND BUS 100A BUS 100A MCB SUPPLIED FROM T -14 EQUIP WITH 100 AMP, 3 POLE CONTACTOR ON MAIN BUS DESCRIPTION KVA LOAD QTY LOAD BREAKER TYPE AMP/ POLE It BREAKER LOAD LOAD # AMP /POLE TYPE QTY DESCRIPTION KVA OFFICE 212 &213 RECEPT 0.7 (4) R 20/1 1 A 2 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT OFFICE 212 &213 RECEPT 03 (4) R 2011 3 B 4 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 0.7 (3) R 20/1 5 C 6 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 0.7 (1) R 2011 7 A 8 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 03 (1) R 20/1 9 B 10 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 0.7 (1) R 20/1 11 C 12 2011 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 03 (1) R 20/1 13 A 14 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT IC 210 RECEPT 03 (1) R 20111 15 B 16 20/1 R (1) 0.7 DISTRIC OFFICE: 200 RECEPT IC 210 RECEPT 03 (1) R 2011 17 C 18 20/1 R (1) 0.7 DISTRIC OFFICE_ 200 RECEPT IC 210 RECEPT 0.2 (1) R 2011 19 A 20 20/1 R (1) 0.7 DISTRIC OFFICE 200 RECEPT COPY MACHINE 1C210 I (1) R 20/1 21 B 22 20/1 R (1) 0.4 OFFICE201 RECEPT CONFER NECE 249 RECEPT 0.4 (2) R 20/1 23 C 24 2011 R (2) 0.5 OFFICE 201 RECEPT CONF ER NECE 209 RECEPT 4.4 (2) R 20/1 25 A 26 20/1 R (4) 0J OFFICE 202 & 203 RECEPT DOOR CHIME 02 (1) R 20/1 27 B 28 20/1 R (4) 0.7 OFFICE 202 & 203 RECEPT ENCLAVE 216 RECEPT 0.5 (3) R 2011 29 C 30 20/1 R (1) 0.2 DOOR CHIME CONF ER NECE 209 TV 0.2 (1) R 2011 31 A 32 20/1 R (3) 0.5 OFFICE 206,207.208 RECEPT IC 210 TV 02 (1) R 2011 33 B 34 20/1 R (3) 0.5 OFFICE 206207,208 RECEPT IC 210 TV 0.2 (1) R 20/1 35 C 36 20/1 R (3) 0.5 OFFICE 206,207,208 RECEPT VAV -17 -11 0.3 (1) RN 20/1 37 A 38 20/1 SR 0 SPARE SPAR E 0 (2) SR 20/1 39 B 40 2011 SR 0 SPARE SPARE 0 20/1 SR 20/1 41 C 42 20/1 SR 0 SPARE Demand Load KVA AMPS 36 Type KVA Factor KVA A08 FRZR FANS , Phase A 5.4 452 37 L 0.0 x 125 0.0 () 0.0 SPARE Phase B 5.3 44.6 PN R 20.6 x 0.5 = 15.3 *100% of 1st 10kva, plus 50% of rerna inder. Phase C 4.8 40.2 A09 FRZR FANS PN 0.3 x 1 = 0.3 41 C Total 15.6 SR () PW 0.0 x 1 = 0.0 Type Average 43.3 KVA MN 0.0 x 1= 0.0 11.5 95.9 *Spares not included L 8.8 MNI 0.0 x 1= 0.0 Phase B 12.5 103.8 R MS 0.0 x1= 0.0 *100% of 1st 10kva, plus 50% of remainder. Phase C 12.8 106.4 PN MW 0.0 x 1= 0.0 20.9 Total Connected KVA 36.7 Total 56.3 PW KT 0.0 x 0.654 0.0 15.6 Total Demand KVA Average 102.0 Total 20.9 0.0 15.6 43.3 Total Demand Amps CONTACTOR SCHEDULE EXISTINS 19 = • ...w ✓�.w,.w ...,. 1-'."1',,,f;,.,. .'t NOV:. a`. >Y, . ..: P .. ., .,.. .... ,. '6.64 .., EQUIP WITH IVOAMP, 3POLE CONTACTOR ON MAW US E REMS- LIGHTING /DOOR HEATERS CONTROLLER SCHEDULE (ROOM 125) KVA LOAD QTY TYPE DEVICE NUMBER PANEL CIRCUITS CONTROLLED NUMBER COIL OF POLES VOLTAGE CONTACT VOLTAGE CONTACT LOAD DESCRIPTION AM PS DESCRIPTION KVA ROOM 10: k9. } .:_- 7- ^ . TG TOYS , FWY C . �a _� .) TOYS fW^ .':t . POWER �'ti:9 >' .C:73. .SMALL Z . ° F 3 K e� .SMALL YYi r Ab SEASON T.F TRACK LTG - SALES FLOOR SPAR.E SPAR E S:±f e SPARE SPARE a'•i.., SPARE F^ �.. �c O. s 89. L`s v 0. 4 ..L 0.9 0 � ? 04fY : � „ . 7F �',@ ° :! (1) 2011 R s0 ,. .: 20' 1 7 .i: t`X�'s':. .2011 20/1 , l 1 ^Ms� SR 201.1 « �w7 F .2311 SR C ^2071 r SR .,,_3,.>, y„ 20/1 REMS -UDH -1 LP -12B 1,3,5,7,9,11,13,15,# 7,19,21 12 120 V 120 V 20 A REFRIGERATED CASES LIGHTS : x (2) (3) SEASONAL R. J C F .E .L a„ SEASONAL POWER ,:a .c )`" 0.2 SEASONAL . .4 . S : r. AL e�..t3: S....^'�,.;_xt ?vJg f. E'+':. `sY tom,',. ^.. -' &V A : POWER POLES " C SEF, �3 .POWER POLES ✓ 9 SEASONAL. POWER. POLES 0 06 SEASONAL POWER POLES 0.6 SEASONAL POWER ERPOLES 0 SP, 6 SPARE t,3 nm 0 SPARE Demand Load Phase A Phase B Phase C Total Average *Spa res not included KVA 4.2 3.0 3.9 11.1 AMPS 35.2 25.0 32.3 30.8 REMS -UDH 2 LP -12A 27 2 120 V 120 V 20 A MARKET DOW NLIGHTS KVA 3.5 7.6 02 0.0 0.0 02 0.0 0.0 0.0 11.1 900% of 1st 10kva, plus 50% of remainder: 10.4 Total Connected KVA 11.1 Total Demand KVA 30.8 Total Demand Amps (3) 0.3 B02 REFR FANS AO6 A07 FRZR LIGHTS REMS -UDH -3 LP -12B 16,18,20,22,24,26,28,30,34 12 120 V 120 V 20 A REFRIGERATE=D CASES DOOR HEATERS C 6 2011 PN (4) T -0627 11/8/2010 x R0 ?''.> 129 :3i:si{ ..w... 4: GYM .f TOP FEED , 006 ii,>1...-3 EXISTINS 19 = • ...w ✓�.w,.w ...,. 1-'."1',,,f;,.,. .'t NOV:. a`. >Y, . ..: P .. ., .,.. .... ,. '6.64 .., EQUIP WITH IVOAMP, 3POLE CONTACTOR ON MAW US E DESCRI:P1 ON KVA LOAD QTY TYPE LOAD BREAKER AMP/ POLE # BREAKER LOAD it AMP /POLE TYPE BREAKER LOAD # AMP /POLE TYPE LOAIO QTY DESCRIPTION KVA ROOM 10: k9. } .:_- 7- ^ . TG TOYS , FWY C . �a _� .) TOYS fW^ .':t . POWER �'ti:9 >' .C:73. .SMALL Z . ° F 3 K e� .SMALL YYi r Ab SEASON T.F TRACK LTG - SALES FLOOR SPAR.E SPAR E S:±f e SPARE SPARE a'•i.., SPARE F^ �.. �c O. s 89. L`s v 0. 4 ..L 0.9 0 � ? 04fY : � „ . 7F �',@ ° :! (1) 2011 R s0 ,. .: 20' 1 7 .i: t`X�'s':. .2011 20/1 , l 1 ^Ms� SR 201.1 « �w7 F .2311 SR C ^2071 r SR .,,_3,.>, y„ 20/1 9 5 7 11 13 L 7 19 � , .23 .25 ,Gf ^.,. z 2 A B C A ,r A w C . . .,.. .2 4 i i.� .r: iw 15 :;18 20 ^ 24 .26 .._.:.} 30 2011 .WM^ > aViY .,t.t;.t�> 20/1 _f/C 50/3 w = 23 4 2011 .:7011 ... ,..sj -, > F,c tk! 7 F:'.a "F SR • R R ::±F �.` SR SR : x (2) (3) SEASONAL R. J C F .E .L a„ SEASONAL POWER ,:a .c )`" 0.2 SEASONAL . .4 . S : r. AL e�..t3: S....^'�,.;_xt ?vJg f. E'+':. `sY tom,',. ^.. -' &V A : POWER POLES " C SEF, �3 .POWER POLES ✓ 9 SEASONAL. POWER. POLES 0 06 SEASONAL POWER POLES 0.6 SEASONAL POWER ERPOLES 0 SP, 6 SPARE t,3 nm 0 SPARE Demand Load Phase A Phase B Phase C Total Average *Spa res not included KVA 4.2 3.0 3.9 11.1 AMPS 35.2 25.0 32.3 30.8 L Type L R PN PW MN MNI MS MW KT Total KVA 2.8 72 0.0 0.O 0.0 0.0 0.0 0.0 410 10.4 B Factor x 1.25 x 0.5 = x 1 = x 1 = x 1 = x 1 = x1 = x 1 = x 0.65 KVA 3.5 7.6 02 0.0 0.0 02 0.0 0.0 0.0 11.1 900% of 1st 10kva, plus 50% of remainder: 10.4 Total Connected KVA 11.1 Total Demand KVA 30.8 Total Demand Amps LP -12B NEW ROOM 125 SURFACE MOU €t+IT TOP FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER) - 10,000 R MS 120 /208 VOLT, 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS 175A MCB SUPPLIED FROM T -15 DESctPTION KVA LOAD On' LOAD BREAKER TYPE AMP! POLE # DESCRIPTION BREAKER LOAD it AMP /POLE TYPE WAD QTY DESCRIPTION KVA A02A03 FRZR LIGHTS 0.5 (4) L 2011 1 A 2 20/1 PN (2) 0.2 B01 B03 REFR FANS A04 A05 FRZR LIGHTS 0.5 (4) L 2W1 3 B 4 20/1 PN (3) 0.3 B02 REFR FANS AO6 A07 FRZR LIGHTS 0.5 (4) L 20/1 5 C 6 2011 PN (4) 0.4 B04 B05 REFR FANS A08 A09 FRZR LIGHTS 0.8 (4) L 20/1 7 A 8 2011 PN (4) 0.4 B06 B07 REFR FANS B011303 REFR LIGHTS 0.6 (2) L 2011 9 B 10 20/1 PN (3) t7 B08 B09 REFR FANS B02 REFR LIGHTS 1.1 (3) 1 20/1 11 C 12 2011 PN (2) 12 B10 FANS B041305 REFR LIGHTS 1.5 (4) L 201-1 13 A 14 2011 PN (3) 02 ABO1 ABO2 A1303 DR FANS B061307 REFR LIGHTS 1.5 (4) L 20/1 15 B 16 20/1 PN (2) 0.7 A02 FRZR DR HTR B08 B09 B10 REFR LIGHTS 02 (5) L 2011 17 C 18 20/1 PN (2) 0.8 A03 FRZR DR HTR ABO1 ABU ABO3 DR LIGHTS 0.2 (3) L 2011 19 A 20 2011 PN (2) 0.7 A04 FRZR DR HTR ABO4 ABO5 DTI" LIGHTS 0.4 (2) L 20/1 21 B 22 20/1 PN (2) 0.8 A05 FRZR DR HTR A01 FRZR FANS 1.3 (4) PN 20/1 23 C 24 20/1 PN (2) 03 A06 FRZR DR HTR A02 FRZR FANS 12 (2) PN 20/1 25 A 26 20/1 PN (2) 0.8 A07 FRZR DR HTR A03 FRZR FANS 1.5 (2) PN 20/1 27 B 28 20/1 PN (2) 1.2 A08 FRZR DR HTR AM FRZR FANS 1.2 (2) PN 2011 29 C 30 2011 PN (2) 0.8 A09 FRZR DR HTR A05 FRZR FANS 1.5 (2) PN 20/1 31 A 32 20/1 PN (2) 0.9 ABO4 ABO5 D/T FANS A06 FRZR FANS 1.2 (2) PN 2011 33 B 34 20/1 PN (2) 0.3 B09 REFR DR HTR A07 FRZR FANS 1.5 (2) PN 2011 35 C 36 2011 SR () 02 SPARE A08 FRZR FANS 1.1 (1) PN 20/1 37 A 38 20/1 SR () 0.0 SPARE A08 FRZR FANS 0.7 (1) PN 20/1 39 B 40 20/1 SR 0 0.0 SPARE A09 FRZR FANS 1.5 (2) PN 20/1 41 C 42 20/1 SR () 02 SPARE Demand Load KVA AMPS Type KVA Factor KVA =,6=r,,,, Phase A 11.5 95.9 L 8.8 x 1.25 11.0 Phase B 12.5 103.8 R 02 x 0.5 = 0.0 *100% of 1st 10kva, plus 50% of remainder. Phase C 12.8 106.4 PN 25.7 x 1 = 25.7 Total 36.7 Total 56.3 PW 0.0 PW x 1 = 0.0 x 1 = 0.0 Average 102.0 MN 0.0 MN x 1 = 0.0 x 1 = 02 Spares not included *Spares not included MNI 0.0 MNI x 1 = 0.0 x 1 = 0.0 MS 0.0 MS x1 = 0.0 x 1 = 0.0 MW 02 MW x 1 = 0.0 x 1 = 34.5 Total Connected KVA 56.4 Total Connected KVA Kr 0.0 KT x0.65 0.0 x0.65 36.7 Total Demand KVA 56.3 Total Demand KVA Total 34.5 Total 56.4 36.7 102.0 Total Demand Amps i• COM . SOT : TOM ,,, , EEO .. . t , v 120 .. , ( BUS r. S;1.-P L......, ..O; , .. ... ,..:.: ,.,.: f.+ ,...,....Os:... r- .,.. ON WIN ..,.,: # DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP! POLE # CU -5 ( DRY STORAGE EV. COIL) BREAKER LOAD LOAD DESCRIPTION # AMP! POLE TYPE QTY KVA (1) BEAUTY DISPLAY PP g EA BEAUTY DISPLAY PP BEA BEAUTY DISPLAY PP BEA SM31,4SSES DISPLAY .1'.P DISNEY t , PLAY PP BEAUTY DISPLAY BEAUTY DISPLAY PP P ,F... xi k.:Y. L Y ... TO ',5 ,`. -e.:> 1 BEAUTY DISPLAY PP BEA BEAUTY DISPLAY PP �^ ,.....i':. ;..c ... , �J.. nr `ni:t.. .t ,... , a, ELECTRONIC t: ELECTRONIC 1.4 1.4 1.4 0.7 1.4 1.4 1. 3 .,. 1.4 1.4 .. :r M` -t,,f 4 R d.aE.: { ) R _. (4) (4) R ,: =>f• > ) PO R 2011 z ors >4� R .i.`.F: 1 (4) R 20 () '£ 0 i 20 .,. /1 (4) R ,..,.<. {) (4) R '1 "' J. n: �,. ... F� It ,� .r , „> .: ,.. 9 .,.., 7.7 , ..A y < °> .4 C .. vn L 1 1.2 HBA POWER POLE { ) ?i c` POWER 0.8 HBA P POLE : >,� I L 1 E £ ) 3�. 77,•1..'.1 H POWER ...:.. t L 1 0.8 BA POLE (1) 20/1 SR 0 SPARE 3::.,: €> `v' t y,i L 't,> r r 4. ..,. ) , . 011 -:' =Wf 0.: :PLANT GONDOLA S PP C F7:' .PP 18 .,.,F ,K }C �.r :. ER . f '%'F.:S a.r PL ^::f .PP .... ^..,: >`I `: .;` �,, F. s - 2 1.8 TRACK. LTG SALES FLOOR L _ ( ) :..t .. : F,a> t, F., IC .4r.W..Trr::9`�a�F sF ELECT"? ,... .,.. C >. > t s} 's0 ELF "xr: _` ;" :TER. i : y x 3r t TER S • 7 x 1..4 ELECTR1C r. PN Demand Load Phase A Phase B Phase C Total Average *Spares not included KVA 9.2 11.2 10.9 31.3 AMPS 76.9 93.3 90.9 87.0 Type L R PN PW MN MNI MS MW KT Total KVA 42 16.0 0.0 11.2 1.O 0.0 00 0.0 02 33.1 PN T -.b Factor T-0621 x 125 6.1 , x 0.5 = 13.0 `100% of 1st 10kva, plus 50% of remainder_ x 1 = 0.0 x 1 = 11.2 x 1 = 1.4 xl = 0.0 x 1 = 0.0 x-1 = 02 33.1 Total Connected KVA x4.65 02 31.3 Total Demand KVA 31.3 87.0 Total Demand Amps �a LP -13 NEB REAR EDC 138 SURFACE MOUNT BOTTOM FEED INTEGRATED SHORT CIRCUIT CURRENT RATING (IER)- 10,400 RMS 120 /248 VOLT, 3 PHASE, 4 WIRE, WITH GROUND BUS 225A BUS MCB 175A SUPPLIED FROM T -13 DESCRIPTION KVA LOAD LOAD BREAKER QTY TYPE AMP /POLE # DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES BREAKER LOAD # AMP /POLE TYPE LOAD QTY DESCRIPTION KVA CU -5 ( DRY STORAGE EV. COIL) 1.9 (1) PN 20/3 1 A 2 1511 PN (1) 0.3 EVAP COIL FAN - CLR 180 1.9 CIRCUIT PN 3 B 4 2011 PN (2) 0.5 D /HTR & H/VENT -FRZR 181 LP- 13/30,32,34 1.9 PN 5 C 6 20/1* PN (2) 0.4 HEAT TAPE - CLR 180 EV_ COIL FAN (DRY STORAGE) 0.2 (1) PN 15/1 7 A 8 1512 PN (2) 0.3 EVAP COIL FAN - FRZR 181 COMPACTOR EXHAUST FAN CU -4(W /IN PRODUCE COOLER) 0.3 1.7 (1) PN PN ..,::B.'1. 20/3 9 11 B A 10 12 `r 2r,.. PN PN (1) 0.1 REFRIG CTRL PNL FRZR 181 1.7 PN 13 B 14 15/2 PN (1) 0.2 EV.COIL FAN (MEAT COOLER) 1.7 PN 15 C 16 PN 0.2 SPARE 0 SR 20/1 17 A 18 15 /1 PN (1) 0.4 EV. COIL FAN (PROD. COOLER SCALE YE1030A 0.3 (1) KT 20/f 19 B 20 rr 3I PN (1) 0.2 HEAT TAPE - PROD, COOLER CU -2 (WALK -IN COOLER) 2.3 (1) PN 30/3 21 A 22 20, <`` R (1) 02 RECEPTACLE RM 184 2.3 PN 23 B 24 30/3 PN (1) 2.7 CU-3 (W/IN MEAT COOLER) 2.3 PN 25 C 26 PN 2.7 CU -1 (WALK -IN FREEZER) 7.1 (1) PN 80/3 27 A 28 PN 2.7 7.1 PN 29 B 30 3013 PN (1) 1.8 CV -1 7.1 PN 31 A 32 PN 12 SPARE 0 SR 20/1 33 B 34 PN 1.8 SPARE 0 SR 2011 35 C 36 20/1 SR 0 SPARE SPARE 0 SR 20/1 37 A 38 2011 SR 0 SPARE SPARE 0 SR 2011 39 B 40 2011 SR 0 SPARE SPARE 0 SR 20/1 41 C 42 20/1 SR 0 SPARE T-0027 ,,,. Demand Load KVA AMPS Type KVA Factor KVA Phase A 18.9 157.5 L 0.0 x 1.25 0.0 Phase B 19.0 158.3 R 0.2 x0.5 = 02 *100 %af 1st 10kva, plus 50% of remainder_ Phase C 18.4 153.3 PN 55.9 x 1 = 55.9 Total 56.3 PW 0.0 x 1 = 0.0 Average 156.4 MN 02 x 1 = 02 *Spares not included MNI 0.0 x 1 = 0.0 MS 02 x 1 = 0.0 MW 0.0 x 1 = 0.0 56.4 Total Connected KVA KT 0.3 x0.65 0.2 56.3 Total Demand KVA Total 56.4 56.3 156.4 Total Demand Amps RTU # ROOF TOP UNITS LOCATION VOLTPH LOAD TYPE WIRE & CONDUIT CONTROL PANEL/ CIRCUIT LOCAL DISC D- DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES 17 ROOF TOP UNIT ROOF 480 3 22.5 KW 3 #8, #8G, 3/ 4 "C EMS HP -1 WI UNIT D VAV VAV ELECTRIC HEAT LOCATION VOLTPH LOAD TYPE WIRE & CONDUIT CONTROL PANEU CIRCUIT LOCAL DISC 0- DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES 17 -1 17 -2 17 -3 17-4 17 -5 17 -6 17 -7 17 -8 17 -9 17 -10 17 -11 VAV BOX / HEAT COIL VAV BOX / H EAT COI L VAV BOX / HEAT COIL VAV BOX / HEAT COIL VAV BOX / HEAT COIL VAV BOX/ HEAT COIL VAV BOX / HEAT COIL VAV BOX / HEAT COIL VAV BOX / HEAT COIL VAV BOX / HEAT COIL VAV BOX ROOM 200 ROOM 200 ROOM 200 ROOM 200 ROOM 209 ROOM 210 ROOM 210 ROOM 215 ROOM 200 ROOM 205 ROOM 207 277 277 277 277 277 277 277 277 277 277 120 1 1 1 1 1 1 1 1 1 1 1.0 KVA 2 #12, #12G, 1/2 "C 1.0 KVA 2#12, #12G, 1/ 2"C 7.5 KVA 2 #8, #8G, 3/4 "C 1.5 KVA 2 #12, #12G, 1/2 "C 2.0 KVA 2 #12, #12G, 1/2 "C 2.5 KVA 2 #12, #12G, 1/2 "C 2.5 KVA 2# 12, #12G, 1/2"C 7.5 KVA 2 #8, #8G, 3/4 "C 1.5 KVA 2#12, #12G, 1/2 "C 1.0 KVA 2#12, #12G, 1/2 "C 0.3 KVA 2 #12, #12G, 1/2 "C EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS EMS H L -2/ 36 H L -2/ 38 HL-2/ 40 HL-2/ 42 HL-2/ 11 HL-2/ 13 H L-2/15 HL-2/17 H L-2/19 H L -2/ 22 LP-15/37 W/ UNIT WI UNIT W/ UNIT W/ UNIT W/ UNIT W/ UNIT WI UNIT W/ UNIT WI UNIT WI UNIT D D D D D D D D D D REFRIGERATION LOCATION VOLTPH LOAD TYPE WIRE & CONDUIT CONTROL PANEL/ CIRCUIT LOCAL DISC D- DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES RTCR -1 COMPRESSOR RACK RTCR -2 COMPRESSOR RACK CU -1 W/ IN FREEZER RM 181 CU -2 W/ IN COOLER RM 180 CU -3 W/ IN MEAT COOLER CU-4 W/ IN PROD. COOLER CU -5 DRY STORAGE ROOF ROOF ROOF ROOF ROOF ROOF ROOF 480 3 480 3 208 3 208 3 208 3 208 3 208 3 62.6 77.1 21.2 6.8 8.1 5.0 5.9 KW SEE RISER KW SEE RISER KW 3#3, 1 -1 /4 "C KW 3#10, 3 /4"C KW 3#10, 3 /4 "C KW 3#10, 3/ 4"C KW 3#10, 3/4 "C R EMS REMS REMS R EMS REMS REMS REMS LP-13/27,29,31 LP- 13/21,23,25 LP- 13/24,25,28 LP- 13/11,13,15 LP- 13/1,3,5 W/ UNIT WI UNIT WI UNIT WI UNIT WI UNIT WI UNIT WI UNIT YE GROCERY # LOCATION VOLTPH LOAD TYPE WIRE & CONDUIT 8 NOVEMBER 2010 CONTROL PANEU CIRCUIT LOCAL DISC D- DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES D- DIRECT CONNECT CV VACUUM PUMP 1/2 "C VOLTPH LOAD TYPE WIRE & R 48" 1 CONTROL PANEU LOCAL C. MUSSER R- RECEPTACLE # LOCATION CONDUIT CHECKED BY CIRCUIT DISC HEIGHT NOTES 1 VACUUM PUMP ROOM 185 208 3 5.5 KW 3 #10, #10G, 3 /4 "C W/ UNIT LP- 13/30,32,34 30A, NF D YE GROCERY # LOCATION VOLTPH LOAD TYPE WIRE & CONDUIT 8 NOVEMBER 2010 CONTROL PANEU CIRCUIT LOCAL DISC D- DIRECT CONNECT R- RECEPTACLE I HEIGHT NOTES 1030-A SCALE PRINTER DRY STORAGE 120 1 0.3 KW 2 #12, #12G, 1/2 "C LP -13/19 R 48" 1 T -0627 °11/8/2010 SCHEDULE NOTES 1. PROVIDE LOW VOLTAGE WIRING TO DATA OUTLET FURNISHED IN CASE. DATE ISSUED ISSUES AND REVISIONS VERSION MR201008 08-06-10 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09-NOV-2010 08:27 la,1001(00 REVIEWED FOR W COMPLIANCE - NEC DEC 21 2010 BUILDING DIVISION RECEIVED NOV 19 2010 PERMIT CENTER GENERAL NOTES A. PROVIDE HANDLE TIES FOR SIMULTANEOUS DISCONNECTING MEANS OF MULTIWIRE BRANCH CIRCUITS PER NEC 210.4. PANELBOARD LOAD LEGEND R RECEPTACLE L - LIGHTING PN - POWER NON- SEASONAL PW - POWER WINTER MN - MOTORS NON- SEASONAL MNI - MOTORS NON- SEASONAL INTERMITTENT MW - MOTORS WINTER KT - KITCHEN SR - SPARE SC - SPACE • - GFCI BREAKER ( ) - INDICATES NUMBER OF CONNECTIONS TO CIRCUIT •• - PROVIDE MECHANICAL TIE FOR SPLIT WIRE RECEPTACLE TARGET STORE SOUTH CENTER WA 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR201008 08-06-10 TITLE PROJECT CODE 270627 CONFIGURATION -LL SCHEDULES SHEET E601 T -0627 SOUTH CENTER, WA 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 I 0 30x72 (H) H A R G I S Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz T: \Remodels \0627 WA South Center R\ ActiveCAD\0627e931.dan O _i W o QVIH JE r—T r—Y EdQV1H 0 QVIH.... aV1H EJIIV_LH J J 218 SPRI \KLER SYSTEV SUPERVISORY SCOPE OF WORK SCOPE A. DISCONNECT AND REMOVE DUCT SMOKE DETECTORS FOR DEMOLISHED ROOFTOP UNITS. REFER TO SHEET ED01 FOR QUANTITY AND LOCATIONS. B. PROVIDE MODIFICATIONS TO EXISTING SPRINKLER SUPERVISORY FIRE ALARM CONTROL PANEL LOCATED IN ADJACENT TARGET STORE FOR NEW DEVICES AS DESCRIBED ON E932. FIELD VERIFY MODE OF EXISTING BOSCH FIRE ALARM CONTROL PANEL LOCATED IN TARGET STORE'S FRONT ELECTRICAL ROOM. ALAR \ SYMBOL LIST - PERMIT SET FIRE CONTROL AUXILIARY FIRE SYSTEM NAC PANEL REMOTE TEST SURGE PROTECTOR CONTROL MODULE FIRE ALARM MONITOR MODULE CEILING HORN PANEL O CEILING XX POWER SUPPLY WALL HORN STROBE WITH CD RATING /STROBE WITH CD RATING WITH CD RATING DETECTOR SWITCH (SUPPLIED BY OTHERS) VALVE SWITCH (SUPPLIED BY OTHERS) LINE RESISTOR (EOL) FIRE PNL AUX PWR ANNUNCIATOR XX FSA WALL STROBE NAC XX STATION O SMOKE DETECTOR OD DUCT SMOKE WATERFLOW PULL STATION TAMPER 0-- END OF /STROBE WITH CD RATING RTS SP CHECKED BY C F M 0 XX GENERAL NOTES ALARM WIRE LEGE \D A. ALARM SYSTEM WILL BE CONNECTED TO A UL CENTRAL MONITORING STATION B. ALARM CONTRACTOR TO MAKE WIRE CONNECTION BETWEEN NEW DUCT SMOKE DETECTORS AND NEW RTS DEVICE. RTS DEVICE SUPPLIED BY ALARM CONTRACTOR. C. SPRINKLER SUPERVISORY SYSTEM MODIFICATIONS SHALL REPLACE EXISTING SYSTEM IN THIS AREA, UNLESS OTHERWISE NOTED. EXISTING TENANT FIRE ALAREM SYSTEM SHALL REMAIN ACTIVE AND BE ENTIRELY REMOVED UPON ACTIVATION OF THE NEW SYSTEM. A. POWER, NAC ACTIVATION AND SLC COMMUNICATION LOOP SHALL BE 14/2 AWG FPL. SLC WIRE SHALL BE TWISTED B. ANNUNCIATOR SHALL BE 16/4 TWISTED SHIELDED AWG FOR COMM. AND 16/2 UNSHIELDED AWG FOR ANNUNCIATOR POWER. C. NOTIFICATION CIRCUIT SHALL BE 12/2 AWG TWISTED PAIR FPL. D. REMOTE TEST SWITCH WIRE SHALL BE 18/4 AWG FPL. NOTE: FIRE ALARM CONDUCTORS SHALL BE SOLID. KEYED \OTES NEW SPRINKLER SUPERVISORY ZONE. CONNECT TO EXISTING SUPERVISORY SYSTEM NAC OR PROVIDE NEW NAC AS 1 PROVIDE SPRINKLER REQUIRED. 219 0 0 r--: 216 E Idl 0 Hd I 200 O O O O O 0 0 daVI -I 2 4EBH 2 0 0 0 0 2 [- O io TADF 2 4EBH (H) 2Lx0C (H) 2Lx0E (H) 2Lx0E PHo I- TA 3 INVESTIGATION CENTER SPRINKLER SUPERVISORY INITIATING & SIGNALING DEVICE PLAN V4 " =1' -0" — FEP24 O 0 024 DATE ISSUED ISSUES AND REVISIONS VERSION MR20100e �u.'.° CONFIGURATION ,oN LL 8 NOVEMBER 2010 11.8.10 - PERMIT SET DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 —NOV -2010 08:59 4FUo -01(.e0 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 21 2010 City of Tukwila BUILDING DIVISION TARGET STORE SOUTH CENTER \WA 301 STRANDER BLVD TUKN/IW WA 98188 STORE T0627 VERSION MR20100e �u.'.° CONFIGURATION ,oN LL TITLE SPRINKLER SUPERVISORY INITIATING &SIGNALING DEVICE PLAN PROJECT CODE 270627 RECEIVED NOV 19 2010 PERMIT CENTER SHEET E931 SOUTH CENTER, WA N N t4 H- INTRUSION SY 9412 SEC SEC CAB KPD MAIN BURGLAR PANEL EQUIP CAB WIRE SPLICE SECURITY SYSTEM KEYPAD V BOL LIST O C MOTION SENSOR CEILING MOUNT DOUBLE DOOR CONTACTS • SINGLE DOOR CONTACTS El KEY NOTE ITEM SZ * ZONE NUMBER FOR THE CIRCUIT INTRUSIO\ KEY NOTES I\TRUSION GENERAL \OTES INTRUSION AREAS AREA 1 AREA 2 AREA 3 AREA 4 AREA 5 AREA 6 AREA 7 AREA 8 PERIMETER NOT USED NOT USED NOT USED NOT USED GROUP OFFICE DISTRICT OFFICE INVESTIGATION CENTER INTRUSION WIRE LEGE\ D A. DATA COMMUNICATION SHALL BE 18/4 AWG TWISTED. USAGE: D1255 KEYPAD. B. CIRCUIT CABLE SHALL BE 22/4 AWG TWISTED. USAGE: DEVICES AND POPIT. C. CIRCUIT CABLE SHALL BE 22/12 AWG TWISTED. USAGE: SPARE WIRE FOR FUTURE. D. POWER AND SIGNAL CABLE 16/2 AWG. USAGE: POWER FOR DEVICES AND PA TRIGGER NOTE: INTRUSION CABLING SHALL BE STRANDED 1000 NICOLLET MALL MINNEAPOLIS, MINNESOTA 55403 — \ n I I •nines IuA r H A R G I S Hargis Engineers, Inc. 600 Stewart Street Suite 1000 Seattle, WA 98101 206.448.3376 fax 206.448.4450 www.hargis.biz 0 II El 4 a 0 8 9 10 m 14 POP BOX. SEE 4/E932. BOSCH D1255 KEYPAD. NOT USED. NOT USED. D59360 PANORAMIC TRITECH DETECTOR. CALIBRATE THE DEVICE TO THE LOWEST SENSITIVITY LEVEL WHILE STILL OBTAINING APPROPRIATE COVERAGE. MULTI CONDUCTOR CABLE. CONTRACTOR TO VERIFY WIRE AS REQUIRED. CONTRACTOR TO FURNISH AND INSTALL WIRING FROM DEVICE TO LOCAL POPIT CABINET (HOMERUN). REFER TO DETAIL NOT USED. GE RECESSED MAGNETIC 1078CTW DOOR CONTACT. MOUNT ON THE TOP OF THE DOOR AND DOOR FRAME. ALIGN THE CONTACTS TO AVOID FALSE ALARMS. REFER TO DETAIL NOT USED. D941 NOT USED. NOT USED. 246 POINT RADIONICS PANEL. TIE INTO SPARE ALARM ZONES IN EXISTING SECURITY SYSTEM PANEL IN REAR ELECTRICAL ROOM (FIELD VERIFY EXACT LOCATION AND SPARE CAPACITY PRIOR TO START OF WORK). A. UTILIZE A D9412GV2 CONTROL COMMUNICATOR FOR THE INTRUSION SYSTEM. REFER TO THE SPECIFICATIONS. TARGET ALARM CENTER (TAC) IN MINNEAPOLIS. MN SHALL MONITOR THE INTRUSION ALARM SYSTEM. THE CONTROL PANEL PROGRAM WILL BE WRITTEN AND DOWNLOADED REMOTELY BY THE TARGET ALARM PROJECTS TEAM. CONTACT THE ALARM PROJECTS AT (800 -622 -0650 OPTION #6) MONDAY - FRIDAY BETWEEN THE HOURS OF 7 :00AM 4 :00PM CENTRAL TIME FOR SYSTEM PROGRAMMING. AFTER THE PROGRAMMING IS COMPLETED, CONTACT THE TARGET ALARM CENTER AT (800- 622 -0650 OPTION *5) FOR TECHNICAL SUPPORT AND PROGRAM CHANGES. B. INSTALL THIS SYSTEM IN COMPLIANCE WITH THE TARGET DRAWINGS AND SPECIFICATIONS. CONSULT THE DRAWINGS FOR WIRING DIAGRAMS, SCHEMATICS, ETC BEFORE BEGINNING SYSTEM INSTALLATION. C. T- TAPPING THE PDC IS NOT PERMITTED. POWERED AND NON- POWERED DEVICE WIRING SHALL BE CLASS B. D. POPITS SHALL BE MOUNTED IN CABINETS. SEE KEY NOTE 3 AND DETAIL 12/E982. E. OUTDOOR DEVICES SHALL BE LISTED FOR OUTDOOR USE AND WEATHERPROOF. F. CONDUIT, BOXES (UNO) FITTINGS, COUPLINGS, CONNECTORS, STRAPS, SUPPORTS. PULL- STRINGS, BUSHINGS ETC SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. WORK SHALL MEET THE REQUIREMENTS OF THE NEC. G. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LINE VOLTAGE (120V. MAX) INSTALLED IN A SEPARATE CONDUIT. INSTALL LOW- VOLTAGE CIRCUITING SHALL BE INSTALLED EXPOSED PER NEC. ARTICLE 760 UNO BY LOCAL JURISDICTIONAL AUTHORITIES AND SHALL BE INSTALLED BY THE SECURITY SYSTEM CONTRACTOR. CABLE BELOW THE BAR JOIST OR OTHER ROOF STRUCTURE PROTRUDING LOWER, OR OTHER LOCATIONS WHERE THE CABLE MAY BECOME EXPOSED AND /OR DAMAGED, MUST BE WITHIN A CONDUIT PROVIDED BY ELECTRICAL CONTRACTOR. H. MOUNT MAIN CONTROL CABINETS AT 60' ABOVE THE FINISHED FLOOR TO CENTER. LABEL 'INTRUSION SYSTEM'. MOUNT POPIT AND SPLICE BOXES IN THE LOCATIONS INDICATED ON SHEET E961 AND LABEL ' INTRUSION SYSTEMS'. I. INSTALL WIRING ON WIRE LAYOUT. SHEETS E961 AND E971 PERMANENTLY IDENTIFY WIRE LAYOUT. PROVIDE NOT LESS THAN 18 INCHES SLACK WIRE AT DEVICES, AND 6 FEET SLACK WIRE AT THE MAIN CONTROL PANEL AND SPLICE BOXES FOR FINAL TERMINATION. METER THE CIRCUITS FOR PROPER INTEGRITY BY A QUALIFIED TECHNICIAN PRIOR TO FINAL TERMINATION. LABEL WIRES BY ZONE NUMBER. J. ONE DEDICATED PHONE AND ONE NETWORK LINES VIA RJ -31X OR RJ -45X JACKS SHALL BE PROVIDED WITHIN TWO FEET OF THE MAIN 9412 CONTROL PANEL THE BLACK BOX RJ31X TELCO JACKS SHALL NOT BE LOCATED INSIDE ANY CABINETS, PER PHONE COMPANY REGULATIONS. REFER TO E981 FOR DETAIL. PROVIDE TELEPHONE CABLE 'FROM RJ31X TO D928 MODULE (RJ45) CABLE'. 9 SZ 13 TO POPIT INPUT DEVICE WIRES /CONDUIT EMBEDDED IN WALL, IF POSSIBLE EOL LOCATED HERE DOOR _J DOOR CONTACT NORMALLY CLOSED WHEN DOOR IS SHUT DOOR CONTACT MOUNTED IN DOOR AND DOOR FRAME DETAIL NOT TO SCALE Edl-I O Hd O cl 2 0 i O 0 0 0 0 2 I� 0 TADF II 4E9H dQVIH 2 n 2 P O O 2 O 4EBH II PH o FTA 3 C• 0 DOOR FRAME SENSOR IN DOOR FRAME SEAL WITH SILICONE SEALANT INVESTIGATION CENTER ACCESS CONTROL & INTRUSION PLAN V4" =1'-0" DATE ISSUED ISSUES AND REVISIONS STORE T0627 8 NOVEMBER 2010 11.8.10 - PERMIT SET LL INTRUSION DRAWN BY C. MUSSER CHECKED BY R. OLSON ARCHITECTS PROJECT NO. 09 -NOV -2010 08:28 — ACCESS CONTROL GENERAL NOTES A. COORDINATE CONSTRUCTION WORK WITH TARGET OSR FOR THE PHASING OF DEMOLITION AND NEW CONSTRUCTION. B. THE REMOVAL OF LOW VOLTAGE CABLE IS THE RESPONSIBILITY OF THE LOW VOLTAGE CONTRACTOR. C. THE ACCESS CONTROL CONTRACTOR SHALL COORDINATE WITH THE DOOR HARDWARE SUPPLIER FOR THE INTERFACE TO THE ACCESS CONTROL SYSTEM. D. THE ACCESS CONTROL CONTRACTOR SHALL COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR ALL POWER REQUIREMENTS. ACCESS CONTROL SYMBOL LEGEND CR DC RTE PROXIMITY SYTLE CARD READER RECESSED /FLUSH MOUNTED DOOR CONTACT SENTROL *SR- 1078CW ELECTRIC DOOR STRIKE REQUEST TO EXIT 'PIR' HOFFMAN MEDIUM TYPE I ENCLOSURE A24N24ALP & A24P24C OR EQUAL 12 GAUGE J O O 0 0 0 O 0 0 0 O 0 O 0 I — I I O 0 0 0 o I o I I I O 0 0 0 0 1 o I I O 0 O 0 I 1 O 0 0 0 o I o 1 I 1 O 0 0 0 0 o L _ _ 1 O 0 0 0 O 0 0 0 0 0 O 0 O 0 POPIT O 0 O 0 O 0 O 0 O 0 O 0 I I I O I I 0 I 0 0 I I I I I 0 11 0 I O 0 I - -I L— —I O 0 O 0 TERMINAL STRIP AS REQUIRED O 0 O 0 0 0 POPIT MOUNTING DETAIL AND SPLICE BOX DETAIL NOT TO SCALE GENERAL NOTES 1. MOUNT POPITS ONLY WITH SCREWS PROVIDED. SECURELY TIGHTEN SCREWS. TO AVOID CONTACT WITH THE BACK SIDE OF THE POPIT'S CIRCUIT BOARD, COVER THE TOPS OF THE SCREWS WITH ELECTRICAL TAPE. 2. SECURE INCOMING CIRCUIT AND DATA WIRES WITH WIRE CLAMPS. IDENTIFY WIRING WITH WIRE MARKERS AND RECORD IN THE SYSTEM'S WIRE LEGEND. MARK (SEE SECTION 26 -0553) SPL BOXES WITH A PLACARD OR OTHER PERMANENT MEANS TO IDENTIFY THE BOX. 3. CONFIGURE POPITS IN ORDER. STARTING WITH THE LOWEST POINT NUMBER TO THE HIGHEST POINT NUMBER. 4. CYLINDER LOCK KIT (AL12AR) SHALL BE SUPPLIEC IF ENCLOSURE IS NOT IN A SECURED ROOM. METAL BACKPLATE *OA() --- 01100 METAL BACKPLATE --REVIEWED .EOH COMPLIANCE WITH NFPATO -NEC DEC 2 2010 City of Tukwila BUILDING DIVISION RECEIVED NOV 19 2010 PERMIT CENTER SHEET E932 T -0627 SOUTH CENTER, WA TARGET STORE SOUTH CENTER ` 301 STRANDER BLVD TUKWILA WA 98188 STORE T0627 VERSION MR201oo8 TITLE INVESTIGATION CENTER CONTROL & PLAN 270627 LL INTRUSION RECEIVED NOV 19 2010 PERMIT CENTER SHEET E932 T -0627 SOUTH CENTER, WA