Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-0963 - DIGITAL FOREST
DIGITAL FOREST 12101 TUKWILA INTERNATIONAL BL EL1O-0963 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 0923049031 Permit Number: EL10 -0963 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Issue Date: 12/08/2010 Permit Expires On: 06/06/2011 Tenant Name: DIGITAL FOREST Owner: Name: INTERNATIONAL GATEWAY WEST Address: 12201 TUKVVILA INTERNATIONAL BLVD , SEATTLE WA 98168 Contact Person: Name: PAT BURKE Address: 900 N 34 , SEATTLE WA 98103 Contractor: Name: TITAN ELECTRIC INC Address: 900 N 34 ST, SUITE 108 , SEATTLE WA 98103 Contractor License No: TITANEI963OB Phone: 206 633 -2811 Phone: 206 - 633 -2811 Expiration Date: 09/02/2012 DESCRIPTION OF WORK: INSTALL (2) 150 KVA TRANSFORMER AND (2) 400 AMP DIST PANELS Value of Electrical Work: NRES: $49,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Fees Collected: $1,169.13 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and =. a ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wit , whether specified herein or not. The granting of this permit does not pre ume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th • erfo ance of wo I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Print Name: L Date: (Z This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-0963 Printed: 12 -08 -2010 PERMIT CONDITIONS Permit No. EL10 -0963 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-0963 Printed: 12 -08 -2010 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://wwwci.tukwila.wa.us Electrical Permit No. Project No. (For•ffice use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION l� ?0h 1 King Co Assessor's Tax No.: .62564/1-- / h Site Address: 1 Z Inn© / 7CG� i �4. �J,t nrr tit, -$.1J OD Suite Number: ! (0 Floor: tia Tenant Name: aZ,/ / )Gr r New Tenant: ❑ Yes ❑..No Property Owners Name: L`e/Y2'iltedY'I /�J7iffir/ �/ i vv Mailing Address: 2 I � ic � :..:; —ry if") ....� State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: t' Mailing Address: A/fzig- E -Mail Address: /like 71/7144 fle,26 ELECTRICAL CONTRACTOR INFORMATION D Telephone: gifie3 City State Zip Fax Number: ('4/ i1f -2/j Z$ Company Name: Mailing Address: Contact Person 4,14 j-j4/,'/-e-' E -Mail Address: %%# 42 7!7111 4l % 4G •� Contractor Registration Number: 77 467 767itr2 City Day Telephone: Fax Number: Expiration Date: 9$id3 State Zip 61633— l� 212�j 2-Z6Y3 Valuation of Project (contractor's bid price): $ 4 /i taro / }} �` Scope of Work (please provide detailed information): l viSftci C�J (g-2 (V,4 • 7ie1 +ors ` corms`. CZ) �vo 4rup DtsT (Pez (� Will service be altered? YesNo Adding more than 50 amps? EK Yes 2o Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel t Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: uget Sound Energy eattle City Light H: \Applications \Forms- Applications On Line4-2007 - Electrical Permit Application.doc bit Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added /altered without service change $50.00 (up to 5 circuits) ❑ Circuits added /altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) , $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed, and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER e R ELECTRICAL CONTRACTOR: Signature: - Print Name: Mailing Address: Date Application Accepted: H:Wpplications \Forms - Applications On Line \4.2007 - Electrical Permit Application.doc bh Day Telephone: Date: //`2Z� "� Date Application Expires: • ( n l tirrt State Staff Initials: Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0923049031 Permit Number: EL10 -0963 Address: 12101 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 11/22/2010 Applicant: DIGITAL FOREST Issue Date: Receipt No.: R10 -02369 Initials: User ID: JEM 1165 Payment Amount: $1,169.13 Payment Date: 11/22/2010 01:16 PM Balance: $0.00 Payee: TITAN ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 09758 1,169.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.00 935.30 000.345.832.00.00 233.83 Total: $1,169.13 doc: Receiot -06 Printed: 11 -22 -2010 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (u0-0b3 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -3670 Project. �'� I � anr Type of Inspection: Address: Date Called: Special Instructions: A Q Date Wanted: /207 r/ a:m m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval: COMMENTS: Inspector: I Date: /2/01/ ri REINSPECTI(�N FEE REQUIRED. Prior to next inspection. ' . fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • PERMIT COORD COPY 0 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -0963 DATE: 11/22/10 PROJECT NAME: DIGITAL FOREST SITE ADDRESS: 12101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEEPPARTMFNTc. burl ding ivision Public Works Fire Prevention Structural Planning Division 111 Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete X- Comments: Incomplete n DUE DATE: 11/23/10 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Building Please Routr REVIEWER'S INITIALS: Structural Review Required n No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12/21/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Printer Friendly Page Page 1 of 1 Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name TITAN ELECTRIC INC UBI No. 602250925 Phone 2066332811 Status Active Address 900 N 34Th Ste 108 License No. TITANEI9630B Suite /Apt. License Type Electrical Contractor City Seattle Effective Date 9/2/2004 State WA Expiration Date 9/2/2012 Zip 98103 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status TITANE *986Q5 TITAN ELECTRIC Electrical Contractor General Unused 11/25/2002 11/25/2004 Expired Electrical Administrator INFORMATION License CROOKT *011 PB Name CROOK, TRAVIS Status Active Business Owner Information Name Role Effective Date Expiration Date FUNG, LAWRENCE H Agent 09/02/2004 8/10/2009 BURKE, PATRICK D President 09/02/2004 $1,000.00 FUNG, LAWRENCE H Secretary 09/02/2004 ELECTRICAL CITATION CROOK, TRAVIS J Vice President 09/02/2004 8/25/2008 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 COLONIAL AM CAS & SURETY OF MD LPM4066933 08/03/2004 Until Cancelled $4,000.00 08/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EREEB00416 8/10/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EREEB00206 2/20/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHAE00321 8/25/2008 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EOXFJ00469 7/29/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $2,000.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 12/08/2010 ROOF 400A PNL 7CA (N) SEC(1) (2) 2 ", 4 #3/0, 1#3 400A PNL 7CB (N) SEC(2) (2) 2 ", 4 #3/0, 1#3 (N) 400A CB (2) 2 ", 4 #3/0, 1#3 225A PNL 1B (E) (E) 225A CB 4TH FLOOR (N) 150 KVA 480/120 STARLINE (E) (E) 225A CB W w U) (E) 225A CB T7C 3/0 (E) 150 KVA 480/120 T7B (E) 150 KVA 480/120 G5 (E) 480V 600A DIST #6 (E) 480V 600A 225A PNL 1A (E) (E) 225A CB STARLINE (E) (E) 225A CB STARLINE (E) (E) 225A CB 400A PNL 6CA (N) SEC(1) (E) 150 KVA 480/120 (E) 150 KVA 480/120 (N) 400A CB (2) 2", 4 #3/0, 1#3 400A PNL 6CB (\) SEC(2) (2) 2 ", 4 #3/0, 1#3 (2) 2 ", 4 #3/0, 1#3 T7A T6 A T6B FILE COPY Pormlt Plan review approval is subject to errors and �ze Approval of c not authorize documents does o the violation of any adopted code or ordinance. Receipt of approved F - s • a is acknowledged Date:.._...._- - City Of Tukwila BUILDING DIVISION B (2) 4 "C, 4- 600kcmil LEVEL P -2 TO SCL rn N co CT CABINET. LOCATE PER SEATTLE CITY LIGHT REQUIREMENTS. REMOTE METER PER SEATTLE CITY LIGHT REQUIREMENTS. 2N4 / PROVIDE TIME DELAY NEUTRAL STYLE ATS 800A -4P BYPASS / ISOLATION ATS, 65KAIC 2N4 QQ �. 00 00 G #4/0 MSB -3 800A ENCLOSED CB 480Y/277V, 30, 4W 65KAIC 2N4 PNC P2H1 (E) 480V 600A 2K4 2K4 MBP -7 (E) 480V 600A 2K4 800A ROLL UP GEN (2) 4 "C, 4- 600kcmil, #4/0 G. BUSS GUTTER 2N4 800A SERVICE DISCONNECT 2N4 MBP -6 (E) 480V 600A (2K4- 2K4 UPS #7 450 KW (E) 480V IN /OUT 500KW /625KVA ENGINE /GENERATOR G2 UPS #6 450 KW (E) 480V I\/OUT (N) 150 KVA 480/120 T6 C SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping . y of Tukwila ......, mvis!ON REVISIONS No t*' r+ges shall be made to the scope of work without prior approval of Tukwila Building Division. NOT; =: i 5 W vrlaior s Mil require a new plan submittal crA may jflc ude additional plan review fee:,. 3/0 STANDBY POWER RISER DIAGRAM SCALE: NONE FEEDER FEEDER SCHEDULE COPPER CONDUCTORS NO. CONDUIT A4 ( 1" A3 1" B4 1 1/4" 1 1/4" 2" 1 1/2" 1 1/2" B3 CH C4 C3 D5 D4 D3 WIRE 4 #4, 1#8 G. 3 - #4, 1#8 G. 4 - #2, 1 #6 G. 3 - #2, 1 #6 G. 3 - #1, 1#1/0 N , 1#6 G. 4 - #1, 1 #6 G. 3 - #1, 1 #6 G. AMPACITY NOTE 2 70 70 115 115 120 130 130 2" 1 1/2" 1 1/4" 5 - WO, 1 #6 G. 4 - WO, 1 #6 G. 3 - WO, 1 #6 G. 136 150 150 E5 E4 E3 F5 F4 F3 G5 G4 G3 H5 H4 H3 2" 5 - #2/0, 1 #6 G. 2" 4 - #2/0, 1 #6 G. 2" 3 - #2/0, 1 #6 G. 156 175 175 2" 5 - #3/0, 1 #6 G. 2" 4 - #3/0, 1 #6 G. 1 1/2" 3 #3/0, 1 #6 G. 2 1/2" 5 - #4/0, 1 #6 G. 2" 4 - #4/0, 1 #4 G. 2" 3 - #4/0, 1 #4 G. 3" 2 1/2" 2 1/2" j 5- 250kcmil, 1 #4 G. 4- 250kcmil, 1 #4 G. 3- 250kcmil, 1 #4 G. 180 200 200 208 230 230 232 255 255 J5 J4 J3 K5 K4 K3 L5 L4 L3 M5 M4 M3 N5 N4 N3 3" 5- 300kcmil, 1 #4 G. 3" 4- 300kcmil, 1 #4 G. 3" 3- 300kcmil, 1 #4 G. 256 285 285 3" 5- 350kcmil, 1 #4 G. 3" 4- 350kcmil, 1 #4 G. 3" 3- 350kcmil, 1 #4 G. 280 310 310 3" 5- 400kcmil, 1 #2 G. 3" 4- 400kcmil, 1 #2 G. 3" 3- 400kcmil, 1 #2 G. 3 1/2" 5- 500kcmil, 1 #2 G. 3" 4- 500kcmil, 1 #2 G. 3" 3- 500kcmil, 1 #2 G. 4" 5- 600kcmil, 1 #2 G. 3 1/2" 4- 600kcmil, 1 #2 G. 3 1/2" 3- 600kcmil, 1 #2 G. 304 335 335 344 380 380 420 420 2H5 2H4 2H3 2J5 2K5 2K4 2K3 (2) 3" 5- 250kcmil, 1 #2 G. EA. (2) 2-1/2" 4- 250kcmil, 1° #2 G. EA. (2) 2-1/2" 3- 250kcmil, 1 #2 G. EA. (2) 3" 5- 300kcmil, 1 #2 G. EA. (2) 3" 5- 350kcmil, 1 #1 G. EA. (2) 3" 4- 350kcmil, 1 #1 G. EA. (2) 2 -1/2" 3- 350kcmil, 1 #1 G. EA. 2M4 2M3 2N4 2N3 3L4 3L3 4H4 4H3 4K4 4K3 464 510 510 512 560 620 620 (2) 3" 4- 500kcmil, 1 #1 /O G. EA. (2) 3" 3- 500kcmil, 1 WO G. EA. (2) 3 -1/2" 4- 600kcmil, 1 #1/O G. EA. (2) 3 -1/2" 3- 600kcmil, 1 #1/O G. EA. 760 760 (3) 3" 4- 400kcmil, 1 #2/0 G. EA. (3) 3" 3- 400kcmil, 1 #2/0 G. EA. (4) 2 -1/2" 4- 250kcmil, 1 #2/0 G. EA. (4) 2-1/2" 3- 250kcmil, 1 #2/0 G. EA. (4) 3" 4- 350kcmil,• 1 #3/0 G. EA. (4) 3" 3- 350kcmil, 1 #3/0 G. EA. 840 840 1005 1005 1020 1020 1240 1240 4N4 4N3 5N4 5N3 6M4 6N4 6N3 (4) 3 -1/2" 4- 600kcmil, 1 #4/0 G. EA. (4)3...1 /2" 3- 600kcm il.�._.1..... #4/O G. EA. (5) 3 -1/2" 4- 600kcmil, 1 #250 G. EA. (5) 3 -1/2" 3- 600kcmil, 1 #250 G. EA. (6) 3" 6- 500kcmil, 1 #250 G. EA. (6) 3 -1/2" 4- 600kcmil, 1 #350 G. EA. (6) 3 -1/2" 3- 600kcmil, 1 #350 G. EA. 1680 1680 2100 2100 2280 2520 2520 SCHEDULE NOTES: 1. CONDUIT SIZING BASED ON RIGID GALVANIZED STEEL CONDUIT TYPE THHN -2 /THWN -2 AND XHHW WIRE TAKING INTO ACCOUNT BOTH CONDUIT FILL AND JAMB RATIO. 2. AMPACITIES LISTED ARE BASED ON THE FOLLOWING TAKEN FROM TABLE 310 -16. A. 60° RATING FOR TERMINATION TO DEVICES © 100A OR LESS PER UL. B. 75° RATING FOR 3W AND 4W FEEDERS. C. 90° RATING FOR 5W FEEDERS DE -RATED TO 80% WHERE PREDOMINATLY HARMONIC CURRENTS ARE PRESENT. NEUTRALS > #1/0 ARE PARALLED ON 5W FEEDERS. 3. INCREASE RACEWAY SIZE FOR OTHER TYPES OF RACEWAYS AND DIFFICULT OR LONG PULLS. 4. GROUND WIRE SIZE INCREASED FOR PARALLEL CONDUCTOR RUNS PER NEC TABLE 250 -95. 5. PROVIDE A SEPERATE ISOLATED GROUND CONDUCTOR ON ALL FEEDERS SHOWN. 6. INCREASE GROUND SIZE FOR GROUNDING ELECTRODES PER NEC TABLE 250 -94. FLAG NOTES: 3 "H CONCRETE HOUSEKEEPING PAD. COORDINATE INSTALLATION REQUIREMENTS WITH SEATTLE CITY LIGHT. 3 PANEL PDU. 2 PANEL PDU. SQUARE D 2350 WITH IOM -4444 I/O MODULE. CITYOFETUKNALA NOV 2 2 2010 PERMIT CENTER t 1,o -off �3 71C17CTAIII ELECTRIC Full Service Electrical Technology Contractor 900 N 34th, Suite 108, Seattle, WA 98103 Phone: 206-633-2811 Fax: 206-374-2128 Email: Info@titanelectric.net 1 REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 6 2010 1' City WIN o lG ila Project Title: 'VISION 1 PERMIT SET DIGITAL FOREST AT INTERGATE WEST 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA Sheet Title: RISER DIAGRAM & PANEL SCHEDULES Designed By: PB Drawn By: JH Project No: Date: Sheet Number: 11/22/10 EO "i1TAl ELECRic•' - - - - -- Project: Location : CktT No. I 1 Receptacle L6-20R 5 Receptacle L6 -20R 9 Race" tacle L6 -20R PANEL SCHEDULE' PANEL :6A Date : i Digital Forest 4th Floor rom : Transformer 60 CIRCUIT NAME P Cb /FU € Load Kva «'1, Receptacle L6 -20R 15 177 Receptacle L6 -20R • C 20 19 h ` Amp P: Rec Heat Motor Ltg Other Total A 20 ,2 16 5 1.6 1.6 1.6 20 2 H y A B 2 21 23 1 L6 -2 R 25 Receptac a D 2i_ . _ ..........,.,,,,, 29 Space c 31 Space _� A 3 i Space ! Q 35 Space Receptacle L6 -20R g B 37 Space lc A? I 39 apace « € B « 41 Space 1 C I : 2 ;Space A 4 Space B 6 Space T TZ IAI 8 Space 10 ISpace 12 Space 14 JSpace 16 Space 18 Space 20 Space 22 Space .. 24 Space__ 26 Space 28 Space 30 ;Space 32 [Space 34 :Space _, 36. Space Section 1 PANEL '- „_,_, _, DESCRIPTION Panel Amps Max Amps L - L Volts. 16 j 16 L - N Volts 1.6 1 6 Phase 1.e j 16 JWire 1.6 5 1;6 A.I.C. l 1.6 1.6 1 6, «11.6 1.6... ! 1 6 Main 0.6. 1.6 £ 1 6 Main Fu. 1 6 « 1 6 ^ Flush 1,6 1;6 Surface Bond Gnd. ,, «,.,, Iso. Gnd. Feed Thru I,, -, - -: f., -::,:_ Sub Feed 38 Space 40 Space 42 Space REMARKS: A B CI ,Top Feed iBtm Feed LOAD SUMMARY ' ( Total, All Sections ) 400. 400 208 120 3 4 x 400 X5 tX€ Rec Kva iHeat Kva -Motor Kva Ltg Kva OtherKva Phase A Phase B 1, !Phase C • i Conn. Kva Conn, Amps ;Demand Kva Demand Amps first 10 kva rec: (a? 100% + balance @ 50% ,N rgest motor @ 125% + balance @. 1.00% lighting @ 125% heating .@ 100% other @ 100% Page 1 22.4 8.0 8.0 6.4 22.4 62 22.4 62 22.4 Sucker Punch(1) pat.xls TITAN ELECTRIC Location Receptacle L6-20R A120 + 1 & 1 b Panel Amps 3 5 !Receptacle L6-20R 7 1 �� € 9 Receptacle L6-2011 £ 11 13 Receptacle L6,2-0R A 20 21 « i 15 Ckt PANEL7A Digital Forest 4th Floor Fed From Transformer 7C CIRCUIT NAME P Cb /Fu Load Kva PANEL SCHEDULE! Dale : Section;. PANEL 1 No h Amp P Rec Heat Motor Ltg Other Iota; DESCRIPTION • A t B 1.6 1 E Max Amps _ C1 20 2 g 1.6 5 1:6 L - LVolts 1,6 1 1,6 L - N Volts 1,6 5 1.6 Phase 1.6 l 1,6 Wire 1 «6, «A.LC. 1.6 1.6 5 I 1.6 1T6« - ..-1.6_ 1.61M,L.O; 1,6 1.6lMain C.B. t 1.6 1,6 5Main Fu. 1 2 ; 16 1 6 '•, Flush 1.6 ,1 6 Surface A B5 20 2'•' 17 Receptacle L6 -20R C 20 l 2 ece tacle L6 -20R Bi 20 23 , _ cJ 25 !Receptacle L6-20R 27 29 Space 31 Space 33 Space ,..,,_,, ,«,_,,,,:, ,•,•.,,,. B � ,,,,,.,...3 Space . 37 Space A 39 Space • B 41 :Space ICI 2 Space 5 A- 4 Space 5 B. 5 6 Space t-' 8 Space 10 Space Space ;5pace - 6 :space 8 Space 20 Space 22 Space 24 Space 26 28 :Space Bond Gnd. Jso. Grid. Feed Thru XI Sub Feed »..1 ,.:Top Feed Btrn. Feed 400 400 208 120 3 4 i K,.,, 400 30 'Space 32 Space 34 Space ,__,_,,,__ ,,w,.,_ -.,_ 36 Space µ« 38 Space 40 Space 5 42 .Space REMARKS: ..,,«,1,,,.._,., l ,,,,,_._.. ;Gann. Kva LOAD SUMMARY ( Total, All Sections ). Rec Kva Heat Kva Motor Kva Ltg Kva Other Kva Phase A Phase B Phase G „ ... y Conn. Amps - Demand Kva I 5Demand Amps first 10 kva rec @ 100%-+ balance @ Page 1 rgest motor @ 126 %. + balance @ lighting @ heating @ other @. 22.4 8.0 8.0 6.4 I 22.4 62 22.4 I 62 100% _ 125% = 100% 100% = 22.4 Sucker_Punch(1) pat.xls 'TITAN ELECTRIC PANEL SCHEDULE PANEL:6B Protect: Digital Forest Location 4th Floor Fed From Panel 6A Ckt CIRCUITNAME P Cb /Fu Load Kva I No i 5 h i Amp P Rec 1 Heat {Motor Ltg I Other# Total ..1 -, :.Spa ,..:. _ - ,,,> ,,, ,,,,,, A I: ,,..,,,,, ,,,, S £a 1.6 1,6 Panel Amps t 3 Space B : 1.6 1 6 Max Amps 5 - - -- Space G! . I 1 « 1.6 ° 1.6 L - L Volts 7 Space A 1.6 T.6 IL N Volts ' Phase g Space,,,..,«,,,,,, ,,,,,_,,,� ..................... .. . . ,,,..�- , - -, _ ,q,,,1,6 1.6-1 11 :Space t 16 1 6 Wire Date.: # Section: PANEL DESCRIPTION : , 113 iSpace A 15 Sipace., B «'17 Space 19 Space 21 ISpace 123 _j Space 25 'Space 27 Space 29 Space 31 Space 33 ISpace µ _35 [Space 1 37 ':Space 39 :Space 1 BI "41Spacc C1 t , 1,6 1 .671A•1.0. I' I .,,, -1 . ............ s ,,.-.: is -- 1 6 I 1.6 1,6 I I 1 . 6 4 1 6 3 1 6 Main C.B. 5 1.6 1.6 Main Fu, 1.6 1.6 Flush 1.6 16 Surface r 4 Space 6 Space C 8 bpai e A 5 I 10 Space B 12 Space C I I 14 'Space Al 16 !Space 18 :Space •Space Space Space Space Space Space 24,, 26 28 30 32 Space 1 34 Space 36 Space Space Space 42 Space REMARKS: € 5 l Btm. Feed Bond Gnd Iso. Gnd. Feed Thru Sub Feed Top Feed 400 400 208 120 3 4 i € LOAD SUMMARY • (l Total, All Sections. ) y_ I £Rec Kva • 5' 1 w...,......£ 5 Heat Kva Motor Kva Ltg Kva Other Kva Phase A Phase B Phase C 1 I :'Conn. Kva Conn, Amps Demand Kva € Demand Amps ,, z,,,,,, ,: s , ;, ;, , ,,,,, first 10 kva rec 1c 100% + balanced 50% r"..'lrgest motor @ 125'/ + balance lighting @ Page 1 heating @ other @ 22.4 8.0 8.0 6,4 22.4 62 22.4 62 100% 125% 100% 100% = 22,4 Sucker_Punch(1) petals TITAN ELECTRIC PANEL SCHEDULE] PANEL :78 Project: Digital Forest SLocation : 4th Floor Fed From : Peale 7A Ckt £ CIRCUIT NAME P Cb /Fu Load Kva 1 5Space 3 Space 5 Space 7 Space 9 11 Space Space 13 Space 15 Space 17 Space 19 ;Space 21 :Space 23 'Space 25 Space 27 Space 29 Space 31 Space 33 Space 35 Space 37,. !Space .......... ..... 3 h i Amp P Rec Heat l Motor Ltg Other Total DESCRIPTION I 1.6 j 1 6 (Panel Amps Date , _ #_ M Section: 1 PANEL B CI 1.6 .6 >, I 1,6 1 -6 1.6 1.6 1,6 1.6 l Max Amps 1 6 I L- L Volts 16 L - NVolts 1.6 Phase Wire A.I.C. 1.6 1,6 1,6 1,.1,6 1.6 1,6 _ 176 i 1,6 IM.L.O. , 1.6 1 1 6 .Main C.B. I« £ 1.6 t 1 6 Main Fu- 1,6 Flush 1,6 1 1.6 Surface 41 :Space 5C {apace _...-,,,..1==.17,S:17.=7ItA 7 5 14 Space 6 Space 8 Space 10_. Space 12 ;Space 14 ISpace 16 ISpace . 18 Space B. B: Space I A ', 20 220_ Space l •`24 i 26 :S ace 1_28 (Space 30ISpace 32 jSpace 34 :Space 36 Space 38 Space 40 Space 42 pace REMARKS : 5 4 l Bond Gad. Iso. Gnd. Feed Thru Sub Feed Top Feed :atm. Feed 400 400 208 120 3 4 x' 400 5 I X LOAD SUMMARY ( Total, All Sections) Rec Kva Heat Kva Motor Kva Ltg Kva Other Kva hPhase A Phase B « Phase C 22.4 8.0 8.0 6.4 !Conn. Kva 22.4 5 :Conn. Amps 62 Demand Kva 22,4 ,,,,,,)DemandAmps 62 . �_ ._....,......s first 10 kva rec @ 100% + balance @ 50% = lrgest motor @ 125% * balance @ 100% Page 1 lighting @ 125% heating @ 100% other @ 100% = 22.4 Sucker_Punch(1) petals LOAD SUMMARY (Per NEC 220 Categories) (277/480Y VOLTS - 3PHASE - 4 WIRE) DIST #6 DEMAND DEMAND DESCRIPTION FACTOR kVA MAX 30 Day Demand 44 1, Added Loads Lighting Receptacles- specific use Receptacles- general use ** Motors Largest motor load Heating Cooling TOTAL CONNECTED LOAD -kVA 36,5 0,0 36.4 0 :0 €,0 0,0 7 *50% Demand On General Use Receptacles Over 1 OKVA ** Does Not Include Receptacles For Specific Equipment 1.25 1.25 1.00 1.00 1.25 1,(10 1:00 0.0 36.4 5.0 0.0 0,0 0,0 LOAD AMPS 53 0 44 0 0 0 X35 <.8 103 @ 480Y/277V 3PH, 4W DESCRIPTION MAX •30 Day Demand LOAD SUMMARY (Per NEC 220 Categories) (2771480Y VOLTS - 3PHASE - 4 WIRE) DIST #7 CONNECTED DEMAND LOAD -kVA FACTOR 35.5 1.25 Added Loads Lighting Receptacles- specific use Receptacles- general use ** Motors Largest motor load Heating Cooling TOTAL 0,0 36.4 0.0 0,0 0.0, 71,9 *50% Demand On General Use Receptacles Over 10KVA * *Does Not. include Receptacles For Specific Equipment 1.25 1.00 1.00 1.25 1.00 1.00 DEMAND LOAD kVA AMPS 44.4 53 0.0 0 36,4 44 5,0 6 0..() 0 0,0 0 0,0 0 0.0 0 85 .,8 103 @ 480Y/277V 3PH, 4W LOAD SUMMARY (Per NEC 220 Categories) (2771480Y VOLTS - 3PHASE - 4 WIRE) MSB #3 DESCRIPTION MAX 30 Day Demand CONNECTED LOAD -kVA DEMAND FACTOR DEMAND LOAD kVA AMPS Added Loads Lighting Receptacles- specific use Receptacles- general use ** Motors Largest motor Toad Heating Cooling TOTAL 71.0 0.0 72,5 0.0 0.0 0.0 143,.5 *50% Demand On General Use Receptacles Over 10KVA ** Does Not Include Receptacles For Specific. Equipment 1.25 1.25 1.00 1.00 1.25 1.00 1.00 88,8 107 0,0 0 72:6 87 x.5.0 6 0.0 0 0,0 0 Q.0 0. 0.0 0: 166.3 200 @ 480Y/277V 3PH, 4W \\ REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC DEC 0 6 2010 City o •Tukwila BUILDING MANN ,.., ELO o9 b3 RECEIV D CITY OF TU !MLA NOV 2 2 Z010 PERMIT CENTER ELECTRIC Full Service Electrical Technology Contractor 900 N 34th, Suite 108, Seattle, WA 98103 Phone: 206-633-2811 Fax: 206-374-2128 Email: 1nfo@titanelectric.net PERMIT SET Project Tide: DIGITAL FOREST AT INTERGATE WEST 12101 TUKWILA INTERNATIONAL BLVD. TUKWILA, WA Sheet Tide: RISER DIAGRAM & PANEL SCHEDULES Designed By: PB Drawn By: III Project No: Date: Sheet Number: 11/22/10