Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL10-1027 - JOS A BANK
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL10 -1027 Jos A Bank 321 Strander Boulevard RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 27 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. JOS A BANK 321 STRANDER BL EL1O-1027 Parcel No.: Address: Tenant Name: CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /wtivw.ci.tukwila.wa.us 2623049064 321 STRANDER BL TUICW JOS A BANK ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL10 -1027 04/28/2011 10/25/2011 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: REGENCY CENTERS LP C/O PROPERTY TAX DEPT , PO BOX 790830 78279 ALLISON WALKER 2495 CAMPUS DR - 2ND FLOOR , IRVINE CA 92612 Phone: 949 - 833 -1930 APEX ELECTRIC INC Phone: 425 - 830 -0282 Address: 13619 MUKILTEO SPDWY - STE D -5 #1105 , LYNNWOOD WA 98087 Contractor License No: APEXEEI977RT Expiration Date: 01/04/2012 DESCRIPTION OF WORK: INTERIOR ALTERATION TO INCLUDE ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING Value of Electrical Work: NRES: $28,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $780.63 National Electrical Code Edition: 2008 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not pres me to give authority to violate or cancel the provisions of any other state or local laws regulating construction o; the performance of . I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this per Signature: Date: \ g °"".' Print Name: \J.,16 vciAttc, This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL10 -1027 Printed: 04 -28 -2011 • • PERMIT CONDITIONS Permit No. EL 10 -1027 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-1027 Printed: 04 -28 -2011 CITY OF TUKWfit Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwila.wa.us Electrical Permit No. L10— 1 0)-7 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: Site Address: Z._ 1 "3 4. (Grw- (\ V( v \ \J (A - Suite Number: Z 1 Floor: i Tenant Name: J OS • A • --o∎1n New Tenant: Yes ❑..No Property Owners Name: -P non C� C� �—} .Q�'s -- 'v'\ c p, e jc, Mailing Address: a 6\ 1 arV 0 CA k (V)1 di l SU 1i- Q \ 000 W o rJ4 . C G. y s °`I 1 City i A State Zip CONTACT PERSON — Who do we contact when your permit is ready to be issued Name: \ ` l S OV\ W Ol -2 V' Day Telephone: qqq -83.3 CAA 3D Mailing Address: Z� CIS C CkVv\ N` YS QY • Zr cX 4t ON \ VVi V1 9- CAA I ? (D 1 Z City E -Mail Address: State Zip SOV1 !, C CC-1 tr CA/1 QCk'S • Fax Number: (O ` °1 � — 11 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ '+ OOO Scope of Work (please provide detailed information): 1 OA .I U QV CA V\ f. Y 013" 0 V1 'v c l v a e w tG v\ Cal , P [ o C-\-V ; C a \ \p\ Ovn\O t✓10 Will service be altered? XI Yes ❑ No Adding more than 50 amps? .i Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served bv: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications\Fonns- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78,75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78,75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature Lac0 -40-v _) Date: (" 2J? / 11 / / 0 Print Name: \AV ( kV Q_ C '"ftY V\ 1 ov WC Vy Day Telephone: qqq J Mailing Address: 24 -S C -rp ts privc 1 V kJ( _ City State Zip IDate Application Accepted: Date Application Expires: Staff Initials: H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 • C City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 321 STRANDER BL TUKW Suite No: Applicant: JOS A BANK RECEIPT Permit Number: EL10 -1027 Status: APPROVED Applied Date: 12/16/2010 Issue Date: Receipt No.: R11 -00822 Initials: User ID: Payee: WER 1655 Payment Amount: $637.10 Payment Date: 04/27/2011 11:54 AM Balance: $0.00 HORIZON RETAIL CONSTRCUTION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 212599 637.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 637.10 Total: $637.10 doc: Receiot -06 Printed: 04 -27 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us Parcel No.: 2623049064 Address: 321 STRANDER BL TUKW Suite No: Applicant: JOS A BANK RECEIPT Permit Number: EL10 -1027 Status: PENDING Applied Date: 12/16/2010 Issue Date: Receipt No.: R10 -02520 Payment Amount: $143.53 Initials: WER Payment Date: 12/17/2010 10:29 AM User ID: 1655 Balance: $574.10 Payee: CARLILE COATSWORTH ARCHITECTS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 20651 143.53 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 143.53 Total: $143.53 (Inc. RPr.eint -0n PrintAd• 12 -17 -2010 Tv INSPECTION RECORD Retain a copy with permit UDioi. INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 5 Type of Inspection: o,l Address: 3474 5n07406%. Date Called: Special Instructions: Date Wanted: 0 a.m. Requester: 1 Phone No: IJApproved per applicable codes. D Corrections required prior to approval. COMMENTS: (W&:{1oii 'l1 (A . ' r(PJkZ Inspector: Date: O D t f n REINSPECTION'FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -- 6300 Southcenter B•Ivd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 INSPECTION NO. Project: 007 f btriK, Type of Inspection: oo. - FJ➢ cT TO CbL D /44-1441-00.1 Address: 32e 1 5DC1c Stc'PoS. Yz_ etirrnie t& Date Called: EA ciottp, PPA514 9 l* Ji t,h6CZ__ i - T MOt.Tt tAt( C4-Uvf t Gs._RavM Special Instructions: ,JEtinks 5 fieruted iwcto4r +fit x-i Date Wanted: 6 00 a. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1S6 .(ZDPeRt1 P 106) - FJ➢ cT TO CbL D /44-1441-00.1 p- k l0a.- (9 Marl 611 Stc'PoS. Yz_ etirrnie t& EA ciottp, PPA514 9 l* Ji t,h6CZ__ i - T MOt.Tt tAt( C4-Uvf t Gs._RavM 1441 1ic‘ CA n r. Do der Self ,JEtinks 5 fieruted iwcto4r +fit x-i vJt(E 5E Date: 06/ if I U REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit alOr 1021 PERMIT NO. CITY OF.TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 x_.(206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project:... /Type of Inspection: 5 Address: ��l Lei WH�vD Date Called: "- Special Instructions: Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: ( C6[ U egr AT ALT: gotx Inspector: Date: t% /o.1 111 1. ( n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD-.` Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter 61' d., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 00-407,1 Project: a_ A IS 11" (1 K. .n'�, Type of Inspection: 0� Address: �n � �, ^ !! Date Called: Special Instructions: Date Wanted: a:ml Requester: Phone No: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: SF9Sn tt, 5‘) 146-4)0 -6) - SJePO T tj C, 11}-(4 12-11 Inspector: /ill 66\146k Date`:._ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION ::RECORD Retain a copy with permit 640 /1)Z-7 PERMIT NO. CITY OF,TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431-2451 Project: 5 4 r' 4... Type of Inspection: 773 ov Address: 32I 51D Date Called: Special Instructions: Date Wanted: / 5 !O(ro 6r%'` p.m. Requester: Phone No: 0 Approved per applicable codes. E Corrections required prior to approval. COMMENTS: KCoNIK IVZoo(ftibtrr eiKeLeff Aer Pkac Inspector: ` pipJ Date: 05 oo /11 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14-- 6300 Southcenter Bivd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 (14 C1 - 2:1 Project: 1 �� 0; Type of Inspection: 3 Address: 2 1 ��� Date Called: Special Instructions. Date Wanted. )pr 6" Requester: Phone No: EiApproved per applicable codes. aCorrections required prior to approval. COMMENTS: £© -115, a LJ D.S Inspector: Ziri l h4uers Date: ,c lac% / n REINSPECTION FEE REQUIRED. Prior to next inspection. feermust'be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. REVI CONPpI 2009 Washin ton State Ener Code Com•liance Form for Nonresidential and Multifamil Residential • • Interior Lighting Summary 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised August 2010 Project Info Project Address Jos. A. Bank Date 1/25/2011 321 Strander Blvd., Suite 321 For Building Department Use FILE COP Y N® All Rooms Applicant Name: Applicant Address: PermPt Applicant Phone: Project Description 1 • New Building • Addition .'4 Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plan: Alteration Exceptions (check appropriate box - sec. 1132.3) 1000.00 not changed • No changes are being made to the lighting and space use ■ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per e** gross inienor Area in ft2 Allowed x Area All Rooms Retial category 1.33 4102 5456 1 Retail Type II Display Allowance 1.40 2658 3721 1 Retail allowance of 1000 -W for spaces larger than 25C 1000.00 1 1000 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts! 10177 Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Type B - Downlight, (2) 32w TRT, Electronic Ballast 20 69 1380 Type B - Exempt Per Footnote 10 4 Type B /NL - Downlight, (2) 32w TRT, Electronic Ballast 5 69 345 Type B /NL - Exempt Per Footnote 10 1 Type C - Exempt Per Footnote 10 14 Type D - Downlight, (1) 50w Par30 3 50 150 Type E - Pendant, (1) 100w Incandescent 2 100 200 Type G - 2'x4' Troffer, (3) F32T8, Electronic Ballast 10 90 900 Type G /NL - 2'x4' Troffer, (3) F32T8, Electronic Ball 3 90 270 Type Q - 2'x2' Troffer, (2) FT4OW /2G11, Electroni Bal 32 68 2176 Type Q /NL - 2'x2' Troffer, (2) FT4OW /2G11, Electroni 8 68 544 Type S - 4' Strip Light, (1) F32T8, Electronic Ballast 4 32 128 E■.• tit./ _t"'O�Serchandise Display Lighting JANCE WMpt - 2' Wall Washer, (2) 39W/2G11, Electronic Bs 36 70 2520 A70- NEC Type - Adj. Downlight, (1) 50w MR16, Electronic Bal 24 50 1200 Total FEB 03 21911 otes. . roposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 9813 1. For propose Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For ack lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. CityofTu tiropose Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage)) and BUILDING DID. a specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage +`•��D h, 5 , or as applicable, the wattage of current limiting devices or of the transformer. For low voltage tra transformer rated wattage. 3. List all fixtures. For exempt li hting, note section and exception number, and leave Watts /Fixture blank. IAN 28 2011 �� LB- 111 I� 11 PERMIT CENTER riv 2009 Washin ton State Ener Code Com•liance Form for Nonresidential and Multifamil Residential • • Interior Lighting Summary (back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised August 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage • Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 • Check if 95% or more of fixtures comolv with 1.2 or 3 and rest are ballaste 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic belles 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA`(W /ft`) Use' LPA`(W /ft`) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants/barst 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail"', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices Tess than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free- standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of fumiture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories!, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of trade attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. i 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, 2009 Washington Motor, and Transformer Permit Plans Checklist LTG -CHK State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Jos. A. Bank IDate 1/25/2011 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requirec Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control /access Schedule with type, indicate locations E -120 Yes 1513.2 Area controls Maximum limit per switch E -120 Yes 1513.3 Daylight zone control Schedule with type and features, indicate locations , E -120 Yes vertical glazing Indicate vertical glazing on plans E -120 N.A. overhead glazing Indicate overhead glazing on plans Yes 1513.4 Display /exhib /special Indicate separate controls E -120 Yes 1513.5 Exterior shut -off Schedule with type and features, indicate location Yes (a) timer w/backup Indicate location E -501 N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location N.A. 1513.6.1 (a) occup. sensors Schedule with type and locations N.A. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans N.A. 1513.7 Hotel /motel controls Indicate location of room master controls Yea 1513.8 Commissioning Indicate requirements for lighting controls commissioning E -501 EXIT SIGNS (Section 1514) Yes I 1514 I Max. watts Ilndicate watts for each exit sign IE -601 LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) N.A. I 1540 'Transformers 'Indicate size and efficiency 1 If "no" is circled for any question, provide explanation: 2009 Washin ton State Ener Code Com•liance Forms for Nonresidential and Multifamil Residential • Mechanical Summary • MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Info Project Address Jos. A. Bank Date 1/25/2011 321 Strander Blvd., Suite 321 For Building Dept. Use Applicant Name: Applicant Address: Applicant Phone: Project Briefly describe system type Description mechanical and features. Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 ?i Includes Compliance Option • Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & compl€ Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception Heat Recovery YIN RTU -1 lA(1) CARRIER 48TCDD12A 114000 ECONO 11.1 EER 11.2 IEER ECONO N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N RTU -1 lAtl) CARRIER 48TCDD12A 147000 ECONO 180000 147000 0.82 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SW HP /BHP Flow ControP Location of Service RTU -1 lAll) CARRIER 48TCDD12A 4000 0.50 2.26 BHP CV ROOF 11f available. 2 As tested according to Table 14 -1A through 14 -1 G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS).6 Exception number from Section 1433. 2009 Washin ton State Ener Code Com•liance Forms for Nonresidential and Multifamil Residential Mechanical Summary (back) MECH -SUM 2009 Washington State Energy Code Compl ance Forms for Nonresidential and Multifamily Residential Revised August 2010 System Description See Section 1421 for full description o p Simple System qualifications. All Systems: 'i No humidification? 'i No Reheat? If Heating /Cooling or Cooling Only: 'i Constant vol? • Split system? • <= 84,000 Btuh? .'i Economizer included? & < =10 Btuh /f?t? i . Air rnnlari� I Parkanari cue? n. � < =1 �5 nnn Rti ih r:nnlinn ran < =15 Rtiih /f2? M • Heating Cap. > 0 If Heating Only: • <1 nnn rfm? • <30% outside air? • Heating Cap. < =10 Btuh /fi? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating /Cooling or Cooling Only Reference Sedion 1421 Simple System Allowed (sedion 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Compl Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Jos. A. Bank (Date 1/25/2011 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment Performance Yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M -601 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss N.A. 1411.1 Air- cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water - cooled chiller Full-load and NPLV values adjusted for any non - standard condiitons N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls Yes 1412.1 Temperature zones Indicate locations on plans M -110 Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M -601 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback M -601 Yes 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage M -601 Yes 1412.4.2 Optimum Start Indicate optimum start controls M -110 N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule Yes 1412.6 Combustion heating Indicate modulating or staged control M -601 Yes 1412.7 Balancing Indicate balancing features on plans M -601 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high- occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers Yes 1412.1 Single zone systems Indicate multiple cooling stage control capability. M -601 Yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M -601 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. Yes 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures and sealing requirements M -601 Yes 1414.1 Duct testing Indicate testing required M -601 Yes 1414.2 Duct insulation Indicate R -value of insulation on duct M -601 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements M -110 Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M -110 Yes 1416.3.4 Documentation Indicate O &M manuals, record drawings, staff training M -110 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report M -110 Yes 1416.4 Compliance Chklist Submit to building official upon substantial completion. M -110 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH -CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Jos. A. Bank (Date 1/25/2011 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Ene gy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R -10 insulation under tank N.A. 1442 Shut -off controls Indicate automatic shut -off of circulators or heat trace Yes 1443 Pipe Insulation Indicate R -value of insulation on piping P-501 N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control No 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R -12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401 -1424 or 1440 -1465 , provide explanation: PEW tAMCY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -1027 PROJECT NAME: JOS A BANK SITE ADDRESS: 321 STRANDER BL Original Plan Submittal Response to Correction Letter # DATE: 01 -28 -11 Response to Incomplete Letter # Revision # 1ermit Issued DEPARTMENTS: din Public Works Fire Prevention Structural Planning Division n ❑ Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1$1 Incomplete n DUE DATE: 02 -01 -11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route X- Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-01 -11 Approved ❑ Approved with Conditions g Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • PLAN MEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -1027 DATE: 12 -16 -10 PROJECT NAME: JOS A BANK SITE ADDRESS: 321 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: g'D � (�l I din Ivlslon Public Works n Fire Prevention Structural Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12 -21 -10 Complete Comments: Incomplete Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01-18-11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PROJECT NAME: J 05 A- wV SITE ADDRESS: .\ 1 PERMIT NO: t Lk() `��-'1 ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATERECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS STAFF INITIALS 1 If—A- Al UIn2 Summary of Revision: Received by: . Summary of Revision: `;►, -<< 6t 2 IV 1 Via g. C-Ofvfili OAs Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE - . STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF .INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE - STAFF INITIALS Summary of Revision: Received by: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us • REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ilea 1 11 Plan Check/Permit Number: E LIo — 1 02.7 ❑ Response to Incomplete Letter # Response to Correction Letter # ( k 1,VLLDI f Pr7 g - ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: :ZS ft B4A,IC — S(5UT4$CENTTER. PI.A2A° Project Address: 321 3yefitt 1!) it 'Gut)) W A- Contact Person: itStly (IC AP Phone Number: g9 q•-$3=-lq ;() Summary of Revision: rt.ECTate& LlLitrail RE V1900 AS A >eE$ULY QG il►tflUr-f XPM2T m F- pr Ann RAN ftal CE j 2T n() Dt,i -A) 64 -1FC, e1,1€42,EP11 tNth,. R vtsso,tk. t 1 .L )E UPOtTC_o Ut-orral ' AO tR AGEs TA-luxe fie 4 � LY t)rrfl n UG l i'a1 CAt elAi Tta . RECEIVED CITY OF TUKWILA U N28ZQ11 oB�tuIIT CE.NTEP Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ViA9 ❑ Entered in Permits Plus on H:Wpplications\Forms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7 -2010 Contractors or Tradespeople Peer Friendly Page • Electrical Contractor A business licensed by LEd to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company APEX ELECTRIC INC 4258300282 13619 Mukilteo Spdwy STE D -5 #1105 Lynnwood WA 98087 Snohomish Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602333705 Active APEXEEI977RT Electrical Contractor 12/30/2003 1/4/2012 General Unused Electrical Administrator INFORMATION License VICHANJ947JJ Name VICHAS, NICHOLAS J Status Active Business Owner Information Name Role Effective Date Expiration Date VICHAS, NICK J Agent 12/30/2003 4/5/2007 VIDHAS, NICK J President 12/30/2003 $250.00 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 1 Savings 1 Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 12/1/2003 Until Released Bond $4,000.00 12/10/2003 Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EVATE00253 4/5/2007 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 04/28/2011 P L_ 1 A2 POWER PLAN SCALE: 1/4" = 1' -0" I . ANY EXISTING CONDITIONS INDICATED ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER. 2. THE CONTRACTOR SHALL VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST THE PLANS, AND FAMILIARIZE HIMSELF WITH THE WORK PRIOR TO BIDDING AND START OF THE WORK. 3. THE CONTRACTOR 15 RESPONSIBLE FOR DEMOLITION OF EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND /OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. 4. RECESSED BOXES AND CONDUITS CONCEALED WITHIN WALLS OR. FLOORS THAT ARE TO REMAIN ARE PERMITTED TO BE ABANDONED IN PLACE ONLY IF THE OPENINGS ARE PATCHED AND THE CONDUCTORS ARE REMOVED. 5. THE OWNER SHALL HAVE FIRST SALVAGE RIGHT ON ALL DEMOLISHED EQUIPMENT, DEVICES, LUMINAIRES, AND MATERIALS. THE CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED EQUIPMENT, DEVICES, LUMINAIRES, AND MATERIALS THE OWNER REJECTS. G. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES, AND LUMINAIRES THAT ARE NOT BEING REMOVED. E3 GENERAL NOTES SALES AREA QUADRUPLEX RECEPTACLE MOUNTED AT +48" A.F.F FOR REFRIGERATOR AND MICROWAVE. EACH DUPLEX RECEPTACLE SHALL BE ON A SEPARATE CIRCUIT. DISCONNECT SWITCH 15 PROVIDED BY EQUIPMENT MANUFACTURER INTEGRAL WITH EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT AND FINAL CONNECTION TO DISCONNECT SWITCH AS INDICATED. DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR SHALL ALSO PROVIDE A REMOTE KEYED TEST STATION WITH VISUAL STATUS ANNUNCIATOR LOCATED NEAR. THE ELECTRICAL PANELS IN THE TAILORING AREA. COORDINATE LOCATION OF REMOTE KEYED TEST STATION WITH AUTHORITY HAVING JURISDICTION AND OWNER PRIOR TO ROUGH -IN ALL FINAL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. GANG TOGETHER WITH LIGHT SWITCH. SEE SHEET E- 120 FOR LOCATION OF LIGHT SWITCH. CONNECT FAN SUCH THAT FAN TURNS ON WHEN ANY ONE RESTROOM'S SWITCH 15 TURNED ON AND ONLY TURNS OFF IF BOTH RESTROOM'S SWITCHES ARE TURNED OFF. PROVIDE ANY RELAYS REQUIRED TO ACCOMPLISH THIS SWITCHING. DEVICE AND ASSOCIATED BRANCH CIRCUIT ARE EXISTING TO REMAIN. INTERCEPT AND EXTEND EXISTING BRANCH CIRCUIT AS REQUIRED TO RECONNECT TO EXISTING CIRCUIT SERVING THIS DEVICE PRIOR TO THE PANEL'S RELOCATION. E4 KEYED NOTES FITTING AREA WOMEN'S TOILET s0 IF NOT EXISTING, DUCT SMOKE DETECTOR AND RELAY FOR HVAC UNIT SUPPLY FAN SHUTDOWN SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR FOR INSTALLATION BY THE MECHANICAL CONTRACTOR. THE ELECTRICAL CONTRACTOR. SHALL ALSO PROVIDE A REMOTE KEYED TEST STATION WITH VISUAL STATUS ANNUNCIATOR LOCATED NEAR THE ELECTRICAL PANELS IN THE TAILORING AREA. COORDINATE LOCATION OF REMOTE KEYED TEST STATION WITH AUTHORITY HAVING JURISDICTION AND OWNER PRIOR TO ROUGH -IN ALL FINAL WIRING SHALL BE BY THE ELECTRICAL CONTRACTOR. PROVIDE FINAL CONNECTION TO INSTANTANEOUS WATER HEATER. THE REQUIRED DISCONNECTING MEANS SHALL CONSIST OF PADLOCK ACCESSORY ON CIRCUIT BREAKER SERVING WATER HEATER BRANCH CIRCUIT TO LOCK CIRCUIT BREAKER IN OPEN (OFF) POSITION. COORDINATE ALL REQUIREMENTS WITH PLUMBING CONTRACTOR PRIOR TO ROUGH -IN. MEN'S TOILET 006 TAILORING AREA TAILOR SHOP EQUIPMENT SCHEDULE TAG EQUIPMENT NAME VOLTAGE/ PHASE WIRE / CONDUIT NOTES OSEWING MACHINE 120 / 1 241 2, 14 1 2 GND., 3/4" C. NEMA 5 -20R OMARKING PRESS TABLE 120 / I 241 2, 141 2 GND., 3/4" C. NEMA 5 -20R 5A IRON RECEPTACLE 120 / 1 24I 2, 141 2 GND_, 3/4" C. NEMA 5 -20R OBLIND STITCH MACHINE 1 20 / 1 241 2, 141 2 GND., 3/4" C. NEMA 5 -20R. 11 TRAVELERS CREASE MACHINE 1 20 / 1 2412, 141 2 GND., 3/4" C. NEMA 5 -20K E6 TAILOR SHOP EQUIPMENT SCHEDULE 5 -5 REvisio s No changes stuff be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Recisions will require a new plan submittal and may include additional plan review fees. B -7 WITH B -2G 8- 22,(25/2, # I 0 WIRE) • ELECT 1 (15/1) +44' +44" Or ?ii!' B -2G 8- 38,(50/3, #8 WIRE) RELOCATED PANEL "A" PANEL "B" WITH A-22 EXISTING 4 -TON RTU TO BUZZER IN TAILOR. AREA ENTRY 002 PUSHBUTTON TO BUZZER\IN TAILOR AREA 8 -32 B -2,4 B -G,8 B -G --� IN CEILI SPACE �2BOVE �,D 1 / 1 _ __J i _l EXISTING 5 -TON RTU COORDINATE SHOW WINDOW RECEPTACLE PLACEMENT WITH LIGHT FIXTURES. SEE SHEET E- 120 FOR FIXTURE LCOATIONS. (TYPICAL) 2 5-10,12,14 ENTRY 4 001 5 PRESS AREA 008 Permit No. SY- 1017 PIr review approval is subject to efars admissions. ii,-;royal of construction documents does not authorize ztation of any adopted code or oninance, Receipt i pproved Fold Copyand condlions 1S ad ed: SEF RATE PERMIT RLQUIRED FOR: MeChanical 0 Electrical lumbing (,as Piping City of Tukwila RU1LONG DIVISION City 01111kirdill DON E D C B REVIEWED .FOR COMPLIANCE WITH NFPA 0 - NEC FEB 0 3 2011 . City of Tukwila BUILDING DIVISION REVISION NOLL L1O (O27 6 RECEIVED JAN 2 8 2011 PERMIT CENTER Calvin J. Coatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 01/25/201 1 s5SchracIcel NewYork ® Omaha Los Angeles 800 -581 -0963 www.schnackel.com :j0s. A. BANK ESTABLISHED 1005', SOUTHCENTER PLAZA 321 STRANDER BLVD. SEATTLE, WA 98188 REVISIONS: 13 DECEMBER, 2010 ISSUED FOR JAB / LU PLAN REVIEW 25 JANUARY, 201 I PLAN CHECK CORRECTIONS PROJECT: 10191 FILE: E I IO.DWG DATE: I2/10/2010 DRAWN BY: NWM SCALE: AS NOTED GROSS AREA SALES AREA A TAILOR. /PRESS AREA FITTING AREA TOILET ROOM SHEET TITLE: POWER PLAN 4, 102 sf 3,005 sf 335 sf 600 sf IG2sf E -110 UNIFORM DRAWING SYSTEM . U.S. NATIONAL CAD STANDARD VERSION 3.1 L (a) (b) 0 (c) 0 (d) 0 (e) 0 on on El 0 (SPST) 0 (SPST) 0 (SPST) 0 (SPST) (SPST) (f) 0 (g) 0 (h) 0 (1) 0 (I) 0 El rinEln • (SPST) 0 (SPST) 0 (SPST) 0 (SPST) 0 (SPST) E4 SWITCH PLATE ELEVATION SCALE: NOT TO SCALE DAYLIGHT AREA SALES AREA (k) 0 0 SWITCHPLATE ELEVATION SCHEDULE SWITCH LOAD CONTROLLED DESCRIPTION a A- I SALES AREA LIGHTING b A -3 SALES AREA LIGHTING c A -5 SALES ACCENT LIGHTING d A -7 SALES DOWN LIGHTING e A -9 SALES DOWN LIGHTING f A- I I SALES ACCENT LIGHTING g A -2 SHOW WINDOW LIGHTING h A -4 SHOW WINDOW LIGHTING 1 A -6 SHOW WINDOW ACCENT LIGHTING J A- 12 SALES DAYLIGHTING k CONTACTOR C -1 MANUAL TIME CLOCK OVERRIDE (TC- I ) I CONTACTOR C -2 MANUAL TIME CLOCK OVERRIDE (TC -2) FITTING AREA WOMEN'S TOILET 1. ANY EXISTING CONDITIONS INDICATED ARE BASED ON INFORMATION PROVIDED BY OTHERS AND POSSIBLE LIMITED FIELD VERIFICATION. THE CONTRACTOR SHALL ADJUST FOR ACTUAL FIELD CONDITIONS AT NO ADDITIONAL EXPENSE TO THE OWNER 2. THE CONTRACTOR SHALL VISIT THE PROJECT SITE, REVIEW EXISTING CONDITIONS AGAINST THE PLANS, AND FAMILIARIZE HIMSELF WITH THE WORK PRIOR TO BIDDING AND START OF THE WORK. 3. THE CONTRACTOR IS RESPONSIBLE FOR DEMOLITION OF EXISTING EQUIPMENT, DEVICES, AND LUMINAIRES AS INDICATED AND /OR AS REQUIRED TO ALLOW FOR INSTALLATION AND CONSTRUCTION OF THE NEW WORK. REMOVE ALL EQUIPMENT, DEVICES, LUMINAIRES, CONDUITS, SUPPORTS, HANGERS, ETC. THAT ARE NOT SHOWN AND ARE REQUIRED TO BE REMOVED IN ORDER TO COMPLETE THE NEW WORK. 4. RECESSED BOXES AND CONDUITS CONCEALED WITHIN WALLS OR FLOORS THAT ARE TO REMAIN ARE PERMITTED TO BE ABANDONED IN PLACE ONLY IF THE OPENINGS ARE PATCHED AND THE CONDUCTORS ARE REMOVED. 5. THE OWNER SHALL HAVE FIRST SALVAGE RIGHT ON ALL DEMOLISHED EQUIPMENT, DEVICES, LUMINAIRES, AND MATERIALS. THE CONTRACTOR SHALL DISPOSE OF ALL DEMOLISHED EQUIPMENT, DEVICES, LUMINAIRES, AND MATERIALS THE OWNER REJECTS. G. MAINTAIN CONTINUITY OF EXISTING CIRCUITS AS REQUIRED TO PROVIDE POWER TO REMAINING EQUIPMENT, DEVICES, AND LUMINAIRES THAT ARE NOT BEING REMOVED. 7. COORDINATE FINAL FIXTURE LOCATIONS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. 8. SEE C5 /E -501, LIGHTING CONTROL DIAGRAM, FOR CONTROL SCHEME OF LIGHTING CIRCUITS. E5 GENERAL NOTES MEN'S TOILET TAILORING AREA PROVIDE FINAL CONNECTION TO SIGN. PROVIDE LOCAL DISCONNECT SWITCH CONCEALED FROM VIEW. COORDINATE SIGN LOCATION WITH SIGN CONTRACTOR PRIOR TO ROUGH -IN. PLACEMENT OF ALL TYPE "E" FIXTURES TO BE COORDINATED WITH FINAL CASHWRAP LOCATION. PENDANTS SHALL BE MOUNTED AT 6-0" A.F.F. LOCATION OF LIGHTING CONTROL TIME OVERRIDE SWITCHES. 5EE DETAILS C5/E -50I AND E4/E-120 FOR MORE INFORMATION. EXISTING LUMINAIRES SHALL BE REPAIRED TO A LIKE -NEW CONDITION, THOROUGHLY CLEANED, AND R.ELAMPED. ANY EXISTING LUMINAIRE THAT 15 DAMAGED BEYOND REPAIR SHALL BE REPLACED WITH AN IDENTICAL LUMINAIRE. MAINTAIN THE EXISTING BRANCH CIRCUIT SERVING THE LUMINAIRE. COORDINATE THE EXACT LOCATION OF THE EXTERIOR. EMERGENCY EGRESS LUMINAIRE IN THE FIELD PRIOR TO ROUGH IN. 6 KEYED NOTES A-26010 WIRE) ( I ) FIXTURE TYPE "5" (fYP ) ELECT; ROOM E RELOCATED PANEL "A" PANEL "B" WITH A- I 1 PRESS AREA NMI ■E■ A- 16, ( #8 WIRE) 30A N.F (2) FIXTURE TYPE "5" (TYP ) ENTRY A -I,3,5 DAYLIGHT AREA NMI ■■■ vJAA 11:3 Ir■ WITH A-12 ■EM ■■■ ■EM ■■■ I2 FIXTURE TYPE "L "(fYP) • ■■M ■ •• DAYLIGHT AREA 30/ I N.F. ENTRY 001 A2 LIGHTING PLAN 1 SCALE: 1/4" = 2 3 4 A- 14, (#10 WIRE) 5 REVIEWED FOR COMPLIANCE ECTH NFP FEB 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED JAN 28 2011 PERMIT CENTER LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUT -OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT, AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCEWITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCE OF THE OPERATIONS SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURE AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER IN ACCORDANCE WITH WASHINGTON STATE ENERGY CODE SECTION 1513.7. E D c B 4116, Calvin J. COatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 01/25/2011 ESTABLISHED 1905 SOUTHCENTER PLAZA 321 STRANDER BLVD. SEATTLE, WA 98188 REVISIONS: 13 DECEMBER, 2010 ISSUED FOR JAB / W PLAN REVIEW 25 JANUARY, 201 I PLAN CHECK CORRECTIONS PROJECT: 10191 FILE: E- 120. DWG DATE: 12/10/2010 DRAWN BY: NWM SCALE: GROSS AREA SALES AREA A TAILOR. /PRESS AREA FITTING AREA TOILET ROOM SHEET TITLE: LIGHTING PLAN AS NOTED 4,102sf 3,005 sf 335 sf GOO sf 1G2 sf •• E-120 UNIFORM DRAWING SYSTEM • U.S. NATIONAL CAD STANDARD VERSION 3.1 E F L_ 1 ENTRY 002 SALES AREA 003 cc Pc OB ?C?C?C?COB ` z Pc FITTING WOMEN'S MEN'S TAILORING AREA TOILET TOILET AREA PATH OF EGRESS AVERAGE 6.5 FC MAXIMUM 9.4 FC MINIMUM 3.1 FC MAX /MIN 3.0: 1 AVERAGE / MIN 2.1 : 1 E6 PHOTOMETRIC STATISTICS � Pia qc Ac o�� pc G G 7.7 B/NL .7 +8.4 +8 + + + I'I +8 7.1 6.9 7.1 +7.9 + 8.3 milign, Al Q Q Q- ac A 1 E Q/N1 %4 4r■ + + + + + + + + + + + + + + + + 6.7 6.6 6.5 6.5 6.6 6.9 7.1 7.1 7.1 7.0 7.0 7.0 6.9 6.6 6.3 5.9 QQ + + + + + + + + 5.7 5.7 6.1 6.4 6.8 7.1 7.2 7.3 Q/NL rApi 7.2 + + + + + + + + + + + + + + + + + + + + + + + + + 7.0 6.9 6.8 6.7 6.9 7.0 7.0 6.9 6.8 6.8 6.7 6.6 6.5 6.3 6.0 5.7 5.5 5.6 5.9 6A 6.5 6.9 7.0 7.0 7.0 +7.3 +7. t +� C. -7-0 ±7.0 ±7 O ±6 3--6.� 6 5 +7.5Q/N • + It. I +7A 72 I'. +7.2 +7.0 +6.9 +7.0 +6.8 +�p.5 +6.7 +6.5 +If.2 +6.5 +0.2 +5.9 + + 6.3 5.9 + + + + + + 7.9 7.4 7.0 6.8 6.5 6 +7.8 +7.3 +7.0 + + 6.7 6.4 G. +7.6 +7.2 +7.0 +6.7 +6.5 B/NL Q Q/NL j AWE A A +1 5 -6 6. 5.7 + i- 6.6 6.2 15.8 +6.3 +0.4 16.1 1 +7.1 +6.7 16.3 +7.5 +7.1 12.7 Q -G.4 ±6.3 -6-3 - r -5 + .9- 5-6- -5.4 -5. Q • E._' a.4. 5.7 OD OD OE OB 1 OB +7.1 +6.9 +6.r +2.9 +6.7 +6.14 G /NL G G G /NL C d OE Cfc Cfc ®B /NL Q +6.7 +6.4 +5.9 +5.2 + + 4.6 4 +6.8 +6.4 +5.9 +5.3 + + 4.6 4. 2.6- 72+5.8 2.4 ±53 52 A MEM MNM +3.4 +3.3 +3.2 +3.3 +3.6 +4 +3.4 +3.2 +3.1 +3.2 + + 3.4 3. MOM ©EM ■11 +5.2 +5.7 +2.4 +7.0 + + 7.4 7 +4.9 +5.5 +6.2 +6.5 + + 7.3 7 VAISI .173.5 -33_ 31 _3.L3J_ 32_3.5_3.& 42�.6_:.52_ 55 6.5-7Q L2 i& 7.i 1.3 74 7.5 A Q A Q A EMI MIN Min G TOT Al +7.3 +6.91 +7.2 +6.81 +61 1 +7.0 +6.2 +51.9 +6.6 +6.21 +551.6 +6.1 +5.8 +51.3 + + +I 5.6 5.3 ! 51.0 +5.t +5.0 +49 +4.8 +4.9 +41.9 +4.7 +4.91 +5I I +4.6 +5.01 +13 +4.6 +5.t +47 4.6 5.3, 0 CQNL Q Q +4.6 +5.4 +4.6 +5.5 + + + 4.5 5.4 6.4 L_ -t 1 +7.1 +7.7 +8.4 + + + 6.8 7.5 81_ +7.2 i+,Z.9 +8.7 +9.2 A +2.8 bc dc A Q Q Q +9 +9.4 +9.0 +8.1 5 + 7. 7.B +8.2 +8.7 +9.0 4.2 +6.3 +6.9 +7.6 +8.9 A Q Q Q Al G /NL G PRESS AREA 008 +8.1 7.3" "7. +8.2 +8.5 +8.7 +8.4 +7.4 +6.6 +7 E D 0 B REVIEWED .FO CON PA OC WITH NEC FEB 0 3 2011 City of Tukwila BUILDING DIVISION DATE: 12/10/2010 • Calvin J. Coatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 01/25/2011 Jos, A. BANK ESTABLISHED 1905 SOUTHCENTER PLAZA 321 STRANDER BLVD. SEATTLE, WA 98188 REVISIONS: A 13 DECEMBER, 2010 I55UED FOR JAB / W PLAN REVIEW 25 JANUARY, 201 I PLAN CHECK CORRECTIONS PROJECT: 10191 FILE: E-121 .DWG ENTRY A2 EMERGENCY PHOTOMETRIC LIGHTING PLAN SCALE: 1/4" = 1' -0" 2 3 4 5 6 RECEIVED JAN 28 2011 PERMITCENTER DRAWN BY: NWM SCALE: A5 NOTED GROSS AREA 4, 102 sf SALES AREA 3,005 sf A TAILOR. /PRESS AREA 335 sf FITTING AREA 600',; TOILET ROOM 162 SHEET TITLE: EMERGENCY PHOTOMETRIC LIGHTING PLAN UNIFORM DRAWING SYSTEM . U.S. NATIONAL CAD STANDARD VERSION 3.1 MOP SINK CEILING 6'-0" 2' -2" STEAM PRESS PRESS 19TA- CITNIE CONTROLS1 FLOOR Dl FULL PRESS AREA ELEVATION SCALE: 1/2" =11-0" 18" ELECTRIC STEAM 1 GENERATOR -_,j VACUUM 4" X 4" SURFACE MOUNT JUNCTION BOX (TYPICAL FOR 2) MOUNT POWER OUTLETS k BEHIND THE ACCESS PANEL=` IN THE CENTER G" A.F.F. uNDERCOUNTER 5-16,18,20 4" X 4" SURFACE MOUNT JUNCTION BOX (TYPICAL FOR 2) PHONE OUTLETS TO BE BEHIND ACCESS PANEL JUST ABOVE RECEPTACLES • T3 (FUT T3 (5 IN FLOOR TS IG 8 -18 MOUNT POW* OUTLETS BEHIND THE/ACCESS PANEL IN THE CATER 6" A.F.F. i.`` — Cl ENLARGED ELECTRICAL PLAN - CASH WRAP SCALE: 1/2" =11-0" I " CONDUIT TO ABOVE ACCESSIBLE CEILING LANDLORD ELECTRICAL ROOM SAFETY SWITCH 200/3, 200A FUSES METERJ NG PER UTI LITY CRITERIA r r 1 1 lh L _i_ J I 4 - #3/0, #G GROUND, 1 #6150. GND., l_ IN 2" CONDUIT r— 1 I I I L-J4 - #3/0, #G GROUND, I #6150. GND., 1 IN 2' CONDUIT AUXILIARY GUTTER EXISTI NG 4 - #3/0, #6 GROUND IN 2" CONDUIT EXISTING 1 1 SAFETY 1 SWITCH I 1 200/3, 200A FUSES L— J EXISTING 4 - #3/0, 1 #6 GROUND IN 2" CONDUIT I� 1METERIG 1 ` M i I PER UTILITY 1 ` 1 CRITERIA LJ EXISTING 4 - #3/0, #G GROUND _1 IN; " CONDUIT 4 - #3/0, #G GROUND IN 2" CONDUIT TERMINATION POINT OF EXISTING SERVICE 4 - #3/0, #G GROUND, #G 150. GND., IN 2" CONDUIT PANEL (RELOCATED) r TENANT SPACE 1 PANEL L - - - -J L - - - -J ALL EQUIPMENT SHOWN IN DASHED LINE IS TO BE PROVIDED AND INSTALLED BY THE LANDLORD Al ELECTRICAL RISER DIAGRAM NOT TO SCALE 1 2 CEILING EXHAUST FAN PILOT LIGHT SWITCH D3 FULL PRESS AREA ELEVATION SCALE: 1/2" = 1' -0" CONNECT TO SEE SHEET E- 1 1110. 0. B- 19 WATER HEATER ELECTRIC STEAM GENERATOR PRESS :MACHINE ONTROLS A- 13, (70/3, #4 WIRE) TAILOR SHOP EQUIPMENT SCHEDULE TAG EQUIPMENT NAME VOLTAGE/ PHASE HP CONDUIT/WIRE DISCONNECT SWITCH NOTES 8B STEAM GENERATOR" 208/3 344, I -#8 GND., 1 1 /4" C. 100 / 3P PROVIDE 70A FRN -IRK FUSE5 9C VACUUM PUMP 120/ I I /2 2412, 1412 GND., 3/4" C. 30 / 1 P PROVIDE MANUAL MOTOR STARTER SWITCH * - STEAM GENERATOR 15 PROVIDED BY THE OWNER AND SHALL BE ORDERED AT 208V, 3 PHASE ENLARGED ELECTRICAL PLAN AND C3 EQUIPMENT CONNECTION SCHEDULE - FULL PRESS AREA SCALE: 1/2" = 1' -0" A3 NOT USED 3 A4 NOT USED 4 E4 MANAGER'S DESK ELEVATION NOT TO SCALE v MOUNTED AT +6' -O" A.F.F. 4' A 6' FLOOR 8' DETAIL NOTES: O"T I " ISOLATED GROUND QUADRAPLEX RECEPTACLE FOR "TTB" MOUNTED AT +7' -0" A.F.F. "51" RECEPTACLES FOR SECURITY SYSTEM MOUNTED AT +8' -0" A.F.F. JUNCTION BOX AND RECEPTACLE MOUNTED AT +G' -0" A.F.F. FOR AUDIO AMPLIFIER AND SPEAKER CONNECTIONS. PROVIDE 1" CONDUIT WITH PULLSTRING FROM MALL TELEPHONE DISTRIBUTION TO TELEPHONE TERMINAL BOARD'TTB" TELEPHONE BOARD ELEVATION & 04 NOTES NOT TO SCALE TC -I MOTO R NC L° 7 NO I -° O° r SQUARE 'D' #850 I CO 15V20 SPDT RELAY MOUNTED IN NEMA I ENCLOSURE I° NC ENO L-_y °_J TOM #55A200, OR EQUAL, TIMED OVERRIDE SWITCH SET FOR 2 HOURS *---717d TC-2 � MOTOR I 1 1 NO I� . NO L -- I �% I NC I I NO I NC ' ool L_ _ — J A -1> A -3 > °- A -5 >--r —� A -8 >- -1-- -o- A -10> SQUARE 0' CLASS 8903, TYPE L ELECTRICALLY HELD LIGHTING CONTACTOR WITH NORMALLY CLOSED CONTACTS MOUNTED IN NEMA I ENCLOSURE r O -0 0 E SPST SWITCH, (TYPICAL) r a1 - c,b1 r— —e1 L°__J ::T::: SPARE TORK #55A200, OR EQUAL, TIMED OVERRIDE SWITCH SET FOR 2 HOURS • A- 1 4 Tc -3, T5 I C�� A -16 °-° --�-- A -18 L — — — J A -12� A -2 A -4 A -G Co/ ° c 0 SQUARE 'D' #8501C0 15V20 SPDT RELAY MOUNTED IN NEMA I ENCLOSURE NC I °NO 1 L_ A -7 > A -9 A- I 1 J EXTERIOR SIGN J EXTERIOR SIGN J EXTERIOR SIGN r - -J1 L° _J r Tn1 L °__J r ri L___1 � - CIRCUIT A -20 r W 0 N °- °- ° - 0 L — — r \od1 L ° - -J e1 1 r�f1 L °__J SPARE J SPARE SALES AREA LTG SALES AREA LTG 5AI FS ACCENT LTG FITTING ROOM LTG TAILOR AREA LTG SALES DOWN LTG SALES DOWN LTG SALES ACCENT LTG SQUARE 'D' CLA55 8903, TYPE L ELECTRICALLY HELD LIGHTING CONTACTOR. WITH NORMALLY CLOSED CONTACTS MOUNTED IN NEMA I ENCLOSURE DAY LIGHTING SHOW WINDOW LTG 51--10W WINDOW LTG SHOW WINDOW ACCENT LTG C5 AUTOMATIC TIMER WIRING DIAGRAM NOT TO SCALE 6 REVIEWED .FOR COMPLIANCE WITH NFPA 70 - NEC JAN 0 3 2011 City of Tukwila BUILDING DIVISION RECEIVED DEC 16 2010 PERMIT CENTER D C B • Calvin J. Coatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 12/13/2010 Schnackel engineers , NewYork n Omaha ® Los Angeles 800 - 581 -0963 www.schnackel.com Jos. A. BANK ESTABLISHED .1905 SOUTHCENTER PLAZA 321 STRANDER BLVD., SUITE 321 SEATTLE, WA 98188 REVISIONS: 13 DECEMBER, 20 I ( ISSUED FOR JAB / Lt./ PLAN REVIEkt PROJECT: 1019 FILE: E -50 I .DWC DATE: 12/10/201C DRAWN BY: NM/ SCALE: AS NOTEE GROSS AREA SALES AREA A TAILOR. /PRESS AREA FITTING AREA TOILET ROOM 4,102 5 3,005 5 335 GOO s 162 s SHEET TITLE: ELECTRICAL DETAILS E -501 UNIFORM DRAWING SYSTEM • U.S. NATIONAL CAD STANDARD VERSION 3.9;. 1 2 MARK SYMBOL DESCRIPTION FIXTURE MANUFACTURER/ TYPE* LAMP MANUFACTURER/ TYPE UNIT TOTAL VOLTAGE TOTAL WATTAGE • Al WALL- MOUNTED DUPLEX RECEPTACLE T4 EMERGENCY LIGHTING UNIT WITH 2 LAMPS 2' RECESSED FLUORESCENT WALLWASHER. ADJUSTABLE IN BOTH THE HORIZONTAL AND VERTICAL FLAN ED. JUNO (2) PHILIPS PL- L3GW/835 120 70 $3 M539 I E -W1 51 D O B RECESSED COMPACT FLUORESCENT DOWNLIGHT LIGHTOLIEK (2) PHILIPS 4 CFTR32WGX2c� -3 120/ 277 69 H 8242U/8038/I 951 B /NL ® L RECESSED COMPACT INTEGRAL BATTERY PACK FLUORESCENT DOWNLIGHT WITH LIGHTOLIER (2) PHILIPS CFTR32WGX24a -3 Z / 69 8242HU /8038 EM/ 195 I C �C RECESSED ADJUSTABLE INCANDESCENT LOW VOLTAGE DOWNLIGHT HALO ( I ) U5H10 50MKI G/NFL24 ( I ) PHILIPS 50MRI G/FL 120 50 HOUSING: H 1499T75 TRIM: 1496P D 0 D RECESSED INCANDESCENT DOWN LIGHT WITH DECORATIVE TRIM JUNG (1) PHILIPS 50PAR3OUHAL/ NFL30 120V 120 50 TC2/9524 -SC E OE INCANDESCENT PENDANT LBL LIGHTING ( I ) PHILIPS I OOA 130V 120 100 H55180-0P-SC-2D G 0 GROUND 2 X 4 FLUORESCENT TROFFER WITH ELECTRONIC BALLAST MERCURY (3) PHILIPS F321-8/11735/ALTO 120 90 OSPEAKER 35- E- 3- 32- OCT -9A- ELB- 120V -2B 0 G /NL ABBREVIATIONS ABBREVIATION DEFINITION 2 X 4 FLUORESCENT TROFFER WITH ELECTRONIC BALLAST AND INTEGRAL BATTERY PACK MERCURY (3) PHILIPS F32T8/TL735 /ALTO 120 90 ri / //' j 0 35- E- 3- 32- OCT -9A- ELB- 120V- 2B- EMPICS NON - FUSIBLE L ELECTRICAL CONTRACTOR tot ` ` SELF POWERED UNIVERSAL MOUNT DUAL -VOLT LED EXIT LIGHT DUAL -LITE INCLUDED 120/ 277 3.8 LXURWE Q:: ST SHUNT TRIP TTB TELEPHONE TERMINAL BACKBOARD 2 X 2 RECESSED FLUORESCENT, 3" DEEP, 9 CELL PARABOLIC MERCURY (2) PHILIPS PL- L40W/835/RS 120 72 504 ME 54- E- 2- 40- BIAX -9 -ELB - 120V FITTING RM LTG. Q/NL 350 2 X 2 RECESSED FLUORESCENT, 3" DEEP, 9 CELL PARABOLIC WITH INTEGRAL BATTERY PACK MERCURY (2) PHILIPS PL- L40W /835/R5 120 72 %AA % ,011 4R I 0 54- E- 2- 40- BIAX -9 -ELM- 1 20V -EM 1 5 1 298 540 4' FLUORESCENT STRJPLIGHT MERCURY (I) PHILIPS F32T8/11L735 /ALTO 120/ 277 32 1 MM- I - 32- OCT -ST- ELB -UNI X 370 EMERGENCY EGRESS LIGHT (VERIFY EXACT MANUFACTURER/MODEL WITH OWNER PRIOR TO BID) LITHONIA (2) LED (INCLUDED) 120/ 277 2 AFN W )Cr E Y Y 0 EXISTING EXTERIOR LUMINAIRE. (SEE SHEET E- 120 FOR ADDITONAL CIRCUITING AND LAMPING INFORMATION) LIGHTOLIER (I) 1 OOW A 19 MAX 120 100 4839 (EXISTING) Al LIGHTING LEGEND 1 2 3 ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION FURNISHED AND INSTALLED BY VENDOR UNDER CONTRACT WITH J05 A BANK. ELECTRICAL CONTRACTOR. TO PROVIDE 2' X 2' PLYWOOD MOUNTING BOARD. PAINT FINISH TO MATCH ADJACENT WALL OF MOUNTING BOARD. TERMINATE ALL PHONE LINES AT'T1" GGM TELEPHONE BLOCK. ALL DATA LINES TO BE TERMINATED IN R148 CONNECTOR, NOT JACK. EXIT LIGHT I=C WALL- MOUNTED DUPLEX RECEPTACLE T4 EMERGENCY LIGHTING UNIT WITH 2 LAMPS IG ISOLATED GROUND WP - WEATHERPROOF TS SINGLE POLE SWITCH CONDUIT, JUNCTION BOXES, CABLING, JACKS, AND ALL OTHER APPURTENANT DEVICES TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CABLING TO BE TAGGED AT ORIGIN, TERMINATION, AND PULL BOXES WITH TAG NUMBER, AND ROOM NAME. ALL CABLING TO BE IN SEPARATE I/2" CONDUIT HOME RUN TO '71" IN TAILOR AREA. GFI RECEPTACLE $3 THREE WAY SWITCH 51 CEILING- MOUNTED DUPLEX RECEPTACLE E0 M I DESCRIPTION: MUSIC SYSTEM AMPLIFIER LOCATION: TELEPHONE TERMINAL BACKBOARD CABLE REQUIRED: N.A. JACK REQUIRED: N.A. ELECTRICAL REQ: ONE 20 AMP DUPLEX RECEPTACLE ON DEDICATED CIRCUIT ELEC. MOUNTING HEIGHT: +G0" A.F.F. II K KEYED SWITCH 4 QUADRUPLEX RECEPTACLE iir PILOT LIGHT SWITCH 0 MOTOR F COMBINATION SWITCH AND FUSE (FUSESTAT) 0 DISCONNECT SWITCH - (SIZE AS INDICATED ON PLAN) 0 SWITCHBOARD / DISTRIBUTION PANELBOARD Q COMMUNICATIONS OUTLET - SEE SCHEDULE :::_:! 0 ® 208/ 1 20V PANELBOARD 0 TELEPHONE BOARD 0 MI 480/277V PANELBOARD ® PUSHBUTTON - WEATHERPROOF WHERE REQUIRED JO JUNCTION BOX Q. BUZZER r \a CONDUIT AND HOMERUN TO PANEL EXIST. LOAD I .25 SIGNAL TRANSFORMER V 0 0 GROUND DUCT SMOKE DETECTOR III OSPEAKER 16882 0 THERMOSTAT ABBREVIATIONS ABBREVIATION DEFINITION ABBREVIATION DEFINITION APP ABOVE FINISHED FLOOR TI TENANT IMPROVEMENT NF NON - FUSIBLE EC ELECTRICAL CONTRACTOR FAO' FIRE ALARM CONTROL PANEL MC MECHANICAL CONTRACTOR GPI GROUND FAULT CIRCUIT INTERRUPTING GC GENERAL CONTRACTOR ST SHUNT TRIP TTB TELEPHONE TERMINAL BACKBOARD D3 ELECTRICAL SYMBOL LEGEND TAG DE5CRIPTI ON REMARKS 1-1 DESCRIPTION: PHONE TERMINAL CONTROL UNIT LOCATION: TELEPHONE TERMINAL BACKBOARD CABLE REQUIRED: N.A. JACK REQUIRED: N.A. ELECTRICAL REQ: ONE 20 AMP I.G. QUADRAPLEX RECEPTACLE ON DEDICATED CIRCUIT ELEC. MOUNTING HEIGHT: +84" A.F.F. FURNISHED AND INSTALLED BY VENDOR UNDER CONTRACT WITH J05 A BANK. ELECTRICAL CONTRACTOR. TO PROVIDE 2' X 2' PLYWOOD MOUNTING BOARD. PAINT FINISH TO MATCH ADJACENT WALL OF MOUNTING BOARD. TERMINATE ALL PHONE LINES AT'T1" GGM TELEPHONE BLOCK. ALL DATA LINES TO BE TERMINATED IN R148 CONNECTOR, NOT JACK. T3 DESCRIPTION: FOR P.C. MODEM LOCATION: CASHWRAP / LOGO WALL CABLE REQUIRED: CAT5 JACK REQUIRED: RJ 1 IC MOUNTING HEIGHT: + 12" A.F.F. BOXES, CABLING, JACKS, AND ALL OTHER. CONDUIT, JUNCTION B R APPURTENANT DEVICES TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CABLING TO BE TAGGED AT ORIGIN, TERMINATION, AND PULL BOXES WITH TAG NUMBER, AND ROOM NAME. ALL CABLING TO BE IN SEPARATE I " CONDUIT HOME -RUN TO '71" IN TAILOR AREA. UTILIZE 66M TELEPHONE BLOCK. T4 DESCRIPTION: MANAGER'S PHONE VOICE TERMINAL LOCATION: MANAGER'S DESK CABLE REQUIRED: CAT5 JACK REQUIRED: RJ I I C MOUNTING HEIGHT: + 18" A.F.F. CONDUIT, JUNCTION BOXES, CABLING, JACKS, AND ALL OTHER APPURTENANT DEVICES TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CABLING TO BE TAGGED AT ORIGIN, TERMINATION, AND PULL BOXES WITH TAG NUMBER, AND ROOM NAME. ALL CABLING TO BE IN SEPARATE 1/2" CONDUIT HOME -RUN TO 'T I " IN TAILOR AREA. TS DESCRIPTION: PHONE VOICE TERMINAL LOCATION: VARIOUS CABLE REQUIRED: CAT5 ' JACK REQUIRED: RJ I I C MOUNTING HEIGHT: +18 A.F.F. UNLESS NOTED OTHERWISE CONDUIT, JUNCTION BOXES, CABLING, JACKS, AND ALL OTHER APPURTENANT DEVICES TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CABLING TO BE TAGGED AT ORIGIN, TERMINATION, AND PULL BOXES WITH TAG NUMBER, AND ROOM NAME. ALL CABLING TO BE IN SEPARATE I/2" CONDUIT HOME RUN TO '71" IN TAILOR AREA. T9 DESCRIPTION : FAX LOCATION: FAX AP CABLE REQUIRED: CAT5 JACK REQUIRED: RJ I 1 C MOUNTING HEIGHT: + 18" A.F.F. CONDUIT, JUNCTION BOXES, CABLING, JACKS, AND ALL OTHER APPURTENANT DEVICES TO BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL CABLING TO BE TAGGED AT ORIGIN, TERMINATION, AND PULL BOXES WITH TAG NUMBER, AND ROOM NAME. ALL CABLING TO BE IN SEPARATE 1/2" CONDUIT HOME -RUN TO 'TI" IN TAILOR AREA. UTILIZE GGM TELEPHONE BLOCK. 51 DESCRIPTION: SECURITY SYSTEM CONTROLLER LOCATION: TELEPHONE TERMINAL BACKBOARD CABLE REQUIRED: 4 PAIR, TWISTED JACK REQUIRED: R.13 I X JACK MOUNTING HEIGHT: +108" A.F.F. ELECTRICAL REQ: TWO 20 AMP DUPLEX RECEPTACLES ON DEDICATED CIRCUIT ELEC. MOUNTING HEIGHT: + 1 08" A.F.F. CONTROLLER, SENSORS, AND WIRING FURNISHED AND INSTAI 1 FD BY WEI 1 S FARGO, INC. UNDER CONTRACT WITH JOS A BANK. M I DESCRIPTION: MUSIC SYSTEM AMPLIFIER LOCATION: TELEPHONE TERMINAL BACKBOARD CABLE REQUIRED: N.A. JACK REQUIRED: N.A. ELECTRICAL REQ: ONE 20 AMP DUPLEX RECEPTACLE ON DEDICATED CIRCUIT ELEC. MOUNTING HEIGHT: +G0" A.F.F. AMPLIFIER AND TERMINATIONS AT AMPLIFIER, SPEAKERS, BACKBOXES, WIRING, CONDUIT, AND OTHER APPURTENANT DEVICES FURNISHED AND INSTALLED BY MUSIC SYSTEM VENDOR UNDER CONTRACT WITH JOS A BANK. D I DESCRIPTION: LAN DATA CONNECTION LOCATION: CASHWRAP CABLE REQUIRED: CAT5 JACK REQUIRED: RJ45 MOUNTING HEIGHT: + 1 2" A.F.F. "D I " JACK IN EACH REGISTER COUNTER TO BE CONNECTED THRU CONDUIT BETWEEN REGISTER COUNTERS. A3 TELECOMMUNICATIONS DEVICE SCHEDULE 3 4 LOADS BASED ON NATIONAL ELECTRIC CODE RELOCATED PANEL A CONNECTED LOAD BY PHASE TOTAL CONNECTED TOTAL DEMAND LOAD 3 PHASE A B C LIGHTING I .25 4863 3970 4541 1 3374 16718 RECEPTACLES 0 360 0 360 360 MOTORS I 0 0 0 0 0 OTHER I 6867 GGG7 GGG7 20201 20201 KITCHEN 1 0 0 0 0 0 NON - SIMULTAN 0 0 0 0 0 0 HEATING ONLY 0 0 0 0 0 0 COOLING ONLY 1 5152 5152 5152 15457 15457 EXIST. LOAD I .25 0 0 0 0 0 G90 1000 LOAD TOTAL 16882 16149 16360 49392 52736 LOADS BASED ON NATIONAL ELECTRIC CODE PANEL B CONNECTED LOAD BY PHASE TOTAL CONNECTED TOTAL DEMAND LOAD 3 PHASE A B C LIGHTING 1.25 0 0 0 0 0 RECEPTACLES 1800 1080 1800 4680 4680 MOTORS I 0 304 448 752 752 OTHER I 6020 7070 5820 18910 18910 KITCHEN 1 0 0 0 0 0 NON - SIMULTAN 0 0 0 0 0 0 HEATING ONLY 0 0 0 0 0 0 COOLING ONLY 1 4768 4768 4768 14303 14303 EXIST. LOAD I .25 0 0 0 0 0 G90 1000 LOAD TOTAL 1 2588 1 3222 12836 38645 38645 D4 ELECTRICAL LOAD SUMMARY -e- -e- -e- CONTACTOR SCHEDULE * CONTACTOR ,, TYPE CONTROLLED CIRCUITS NUMBER OF POLES C I SQUARE 'D' #LG SERIES A- I ,3,5,8, I O G (NC) C2 SQUARE 'D' #LG SERIES A -7,9, I I G (NC) * - ALSO SEE DETAIL C5/E -50I AUTOMATIC TIMECLOCK SCHEDULE TAG DESCRIPTION MFR. CAT. NUMBER HOURS OF OPERATION TC- I DPDT, 120V, 40 AMP TIMECLOCK WITH 7 -DAY DIAL AND RESERVE POWER SUPPLY TORK W220L 9:45AM -9: 1 5PM TC 2 DPDT, 120V, 40 AMP TIMECLOCK WITH 7 -DAY DIAL AND RESERVE POWER SUPPLY TORK W220L 9:45AM-9: 1 5PM TC -3 3PST, 120V, 40 AMP TIMECLOCK WITH 7 -DAY DIAL AND RESERVE POWER SUPPLY TORK W300L S :OOPM- I I :00PM TC-4 4PST, 120V, 40 AMP TIMECLOCK WITH 7 -DAY DIAL AND RESERVE POWER SUPPLY TOM W400AL 9 :45AM -9: 1 5PM D5 TIMECLOCK AND CONTACTOR SCHEDULES RELOCATED PANELBOARD "A" SCHEDULE SERVES LOAD A ML P 5 P 0 E 5 C K T # C K T # A M P 5 1, 0 L E S LOAD SERVES A B C A B C CON NON CON NON CON NON CON NON CON NON CON NON SALES AREA LTG 648 830 20 I I 2 20 1 1 104 1 000 SHOW WINDOW LTG SALES AREA LTG 432 1500 20 I 3 4 20 1 G90 1000 SHOW WINDOW LTG SALES ACCENT LTG 1 330 360 20 I 5 G 20 I 1 500 1 000 SHOW WDW ACCENT LTG SALES DOWN LTG. 207 180 20 I 7 8 20 1 504 1 000 FITTING RM LTG. SALES DOWN LTG. 350 3G0 20 1 9 I 0 20 1 1 298 540 TAILOR AREA LTG. SALES ACCENT LTG 419 370 20 1 1 1 12 20 1 1 292 900 SALES DAYLIGHTING STEAM GENERATOR GGG7 70 3 13 14 20 I 1 200 900 EXTERIOR SIGNAGE SECURITY RECEPTS GGG7 - -- -- 15 16 20 1 1 200 360 EXTERIOR SIGNAGE TELEPHONE EQUIPMENT GGG7 - -- -- 17 18 20 1 180 SPARE EXIST. 4 -TON RTU 2438 30 3 19 20 20 1 200 LIGHTING CONTROLS VACUUM PUMP 2438 - -- -- 21 22 20 1 360 RTU RECEPTS. PRESS MACHINE CONTROLS 2438 - -- -- 23 24 20 1 2050 SPARE EXIST. 5 -TON RTU 2714 30 3 25 26 20 1 1 200 720 EXTERIOR SIGNAGE EF- I 2714 - -- -- 27 28 20 1 180 SPARE EP -2 2714 - -- -- 29 30 20 I I 80 SPARE SPARE 20 1 31 32 20 I 1 000 SPARE SPARE 20 1 33 34 20 1 v v v v v SPARE SPARE 20 1 35 3G 20 I 720 SPARE SPARE 20 1 37 38 20 1 ' -- SPARE SPARE 20 1 39 40 20 1 4768 SPARE SPARE 20 1 41 42 20 I 4768 SPARE 855 11819 782 11819 1749 11819 4008 200 3188 360 2792 0 VOLTAGE 208/1 20V, 3P, 4W AMPS 225 LOCATION TAILORING AREA SECT I MTG 5 MAIN M.L.O. AIC SPECS REMARK5 GROUND BUS A B C DESIGN VA 52736 CONNECTED LOADS: 1 6882 1 6 1 4 9 16360 DESIGN AMPS 1 5 I CONNECTED VA 49392 Vn-41 PANELBOARD "B" SCHEDULE SERVES LOAD A ML P 5 P OK E 5 C T # C K T # A ML P 5 P 0 E 5 LOAD SERVES A B C A B C CON NON CON NON CON NON CON NON CON NON CON NON REFRJGERATOR 830 20 I I 2 20 1 1 000 MARKING PRESS TABLE(4) MICROWAVE 1500 20 I 3 4 20 1 1000 IRON(5A) MANAGER'S PC 360 20 I 5 G 20 I 1 000 SEWING MACHINE(3) MANAGER'S RECEPT 180 20 I 7 8 20 1 1 000 BOND STITCH MACHINE(9) TOILET RECEPTS 3G0 20 I 9 10 20 II 540 SALES AREA RECEPTS EWC 370 20 1 I I 12 20 I 900 SHOW WINDOW RECEPTS AUDIO RECEPT I 80 20 1 13 14 20 I 900 SHOW WINDOW RECEPTS SECURITY RECEPTS 360 20 1 15 1G 20 1 360 CASHWRAP IG QUAD TELEPHONE EQUIPMENT 360 20 I 17 18 20 i1 180 CASHWRAP IG RECEPT WATER HEATER 1 650 20 I 19 20 20 1 360 CASHWRAP IG QUAD VACUUM PUMP 1800 20 I 21 22 25 2 2050 INSTA -HOT (IWH) PRESS MACHINE CONTROLS 1 500 20 1 23 24 - -- -- 2050 SPARE 20 1 25 26 20 it 720 BACK OF HOUSE RECEPTS EF- I 304 15 I 27 28 20 I 180 BACKWRAP IG RECEPT EP -2 448 15 1 29 30 20 1 I 80 BACKWRAP IG RECEPT SPARE 20 I 3 I 32 20 1 1 000 CREASE MACHINE(I I) SPARE 20 I 33 34 v v v v v vSPAtE L SPARE 20 I 35 36 20 1 720 SHOW WINDOW RECEPTS SPARE 20 I 37 38 e ' -- 5,TU I SPACE ONLY 39 40 - -- - 4768 SPACE ONLY 41 42 - -- -- 4768 0 2840 0 4324 0 3038 0 9748 0 8898 0 9798 VOLTAGE 208/1 20V, 3P, 4W AMPS 225 LOCATION TAILORING AREA SECT I MTG 5 MAIN 200/3 AIC SPECS REMARKS GROUND BUS A B C DESIGN VA 38645 CONNECTED LOADS: 1 2588 13222 1 2836 DESIGN AMPS 1 10 THIS PANEL SHALL BE EQUIPPED WITH AN ISOLATED GROUND BUS IN ADDITION TO THE EQUIPMENT GROUND BUS CONNECTED VA 38645 PANELBOARD NOTES: H-e-H SYMBOL DENOTES LOCK -ON TYPE CIRCUIT BREAKER. A4 PANELBOARD SCHEDULES ELECTRICAL CONTRACTOR SHALL PROVIDE HANDLE TIES FOR ALL SINGLE POLE CIRCUIT BREAKERS THAT SERVE CIRCUITS THAT COMPRISE A MULTIWIRE BRANCH CIRCUIT TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS IN THE MULTIWIRE BRANCH CIRCUIT. 5 REVIEWED FOR COMPLIANCE WIITH NFPA o FEB 0 3 2011 City of Tukwila BUILDING DIVISION 6 E D C B • 4., Calvin J. Coatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 01/25/2011 Schnackel engineers,, NewYork 0 Omaha ® Los Angeles 800- 581 -0963 www.schnackel.com Jos. A. BANK ESTABLISHED' 1905 SOUTHCENTER PLAZA 321 STRANDER BLVD. SEATTLE, WA 98188 REVISIONS: 13 DECEMBER, 2010 ISSUED FOR JAB / LL/ PLAN REVIEW 25 JANUARY, 201 1 PLAN CHECK CORRECTIONS PROJECT: 10191 FILE: E -60 I .DWG DATE: 12/10/2010 DRAWN BY: NWM SCALE: GROSS AREA SALES AREA A TAILOR. /PRESS AREA FITTING AREA TOILET ROOM RECEIVED JAN 28 2011 PERU CENTER ER AS NOTED 4,102 sf 3,005 sf 335 sf GOO sf 162 sf SHEET TITLE: ELECTRICAL SCHEDULES AND LEGENDS UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERSION 3.1 L 2 3 I.01 GENERAL ENTIRE INSTALLATION SHALL BE MADE IN STRICT ACCORDANCE WITH THE CURRENT EDITION OF THE NATIONAL ELECTRICAL CODE, LOCAL CODES AND THE LANDLORD'S REQUIREMENTS. REFER IN PARTICULAR TO LANDLORD'S TENANT HANDBOOK. B. SECURE AND PAY FOR ALL REQUIRED PERMITS. C. ELECTRICAL WORK SHALL BE COMPLETE IN EVERY DETAIL. ALL MISCELLANEOUS MATERIALS AND LABOR NECESSARY TO COMPLETE THE WORK DESCRIBED, SHOWN, OR REASONABLY IMPLIED, ON DRAWINGS OR SPECIFICATIONS, SHALL BE INCLUDED IN THE CONTRACT. CONTRACTOR SHALL MAKE MINOR ADJUSTMENTS TO THE WORK WHERE REQUESTED BY THE TENANT WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. D. VERIFY EXISTING CONDITIONS AT THE SITE. ELECTRICAL CONTRACTOR SHALL VISIT THE SITE AND OBSERVE ALL EXISTING CONDITIONS BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. EXTRAS WILL NOT BE ENTERTAINED FOR FAILURE TO MAKE THIS VISIT. E. ELECTRICAL CONTRACTOR SHALL ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. F. CONFORM TO GENERAL CONTRACTOR'S SCHEDULE AND INSTRUCTIONS THROUGHOUT THE DURATION OF THE. AT NO TIME SHALL ANY WORK BE UNDERTAKEN WHICH SHALL INTERFERE WITH THE NORMAL OPERATION OF BUSINESS. ANY SHUTDOWN MUST OCCUR AFTER REGULAR BUSINESS HOURS AND MUST BE CLEARED WITH THE MANAGEMENT WITH PROPER PRIOR NOTICE GIVEN TO THE OWNER'S REPRESENTATIVE. G. CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER OF ERRORS, OMISSIONS OR DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK. FAILING TO PROVIDE SUCH NOTICE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, ARCHITECT OR ENGINEER. 2.0 I MATERIALS A. GENERAL ALL EQUIPMENT SHALL BE UL LISTED. 2. FURNISH ALL MATERIAL AND EQUIPMENT AS SPECIFIED, EXCEPT WHERE SPECIFIC APPROVAL FOR SUBSTITUTION IS GIVEN BY THE TENANT. 3. PROPOSAL SHALL BE BASED ON SPECIFIED MATERIAL AND EQUIPMENT. IN ORDER TO PROMOTE COMPETITION, HOWEVER, BIDDERS ARE ENCOURAGED TO SUBMIT ALTERNATE PROPOSALS ON ANY ALTERNATE MATERIALS AND /OR EQUIPMENT THEY WISH TO PROPOSE, INCLUDING ANY PRICE CHANGES EFFECTED BY ACCEPTANCE OF ALTERNATES. 4. COST OF ANY CHANGES REQUIRED BY OTHER TRADES DUE TO SUBSTITUTION OF ALTERNATE EQUIPMENT SHALL BE INCLUDED IN THE ALTERNATE PROPOSAL. 5. ALTERNATE PROPOSALS WILL BE ACCEPTED OR REJECTED BEFORE ISSUANCE OF CONTRACTS. NO CHANGES WILL BE ALLOWED AFTER THE CONTRACT IS SIGNED. B. ELECTRICAL EQUIPMENT I . LIGHTING AND APPLIANCE PANELBOARDS a. EXISTING 2. CIRCUIT BREAKERS a. ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE. b. LIGHTING CIRCUITS WHICH ARE SWITCHED AT PANELS SHALL BE FITTED WITH SWITCHING DUTY RATED "SWD" BREAKERS. c. FURNISH AND INSTALL HANDLE LOCKS WHERE SHOWN ON THE DRAWINGS. 3. FUSES a. ALL FUSES GOO AMPERES OR LESS SHALL BE UL LISTED, CLASS RK I OR J, LOW -PEAK, DUAL ELEMENT, TIME DELAY, 600 VOLT. ACCEPTABLE MANUFACTURES ARE BUSSMAN, GOULD OR SHAWMUT. C. WIRING DEVICES I. RECEPTACIF, a. DUPLEX: HUBBELL #5362 OR EQUAL b. QUADRUPLEX: TWO HUBBELL #5362 OR EQUAL IN A COMMON JUNCTION BOX WITH A 4 -GANG COVERPLATE. c. GFCI DUPLEX: HUBBELL #GF -5362 WITH "A8" ALUMINUM COVER PLATE. d. ISOLATED GROUND DUPLEX: HUBBELL #1G5362 OR EQUAL e. ISOLATED GROUND QUADRUPLEX: TWO HUBBELL #IG5362 OR EQUAL IN A COMMON JUNCTION BOX WITH A 4 -GANG COVERPLATE. 2. TELECOMMUNICATIONS OUTLETS a. TELEPHONE: HUBBELL TYPE RJ I I G, OR EQUAL, WITH COVER PLATE. b. MODEM: HUBBELL TYPE RJ I I C, OR EQUAL, WITH COVER PLATE. c. HYPERCOM: HUBBELL TYPE R.11 I C, OR EQUAL, WITH COVER PLATE. d. DATA: HUBBELL TYPE RJ45, OR EQUAL, WITH COVER PLATE. 3. SWITCHES a. SINGLE-POLE: HUBBELL #HBL -1221 OR EQUAL b. THREE -WAY: HUBBELL #H5L -1223 OR EQUAL c. PILOT LIGHT: HUBBELL #HBL- 122 I -IL OR EQUAL 4. COVERPLATES a. STANDARD SIZE, THERMOPLASTIC. COLORS AS SCHEDULED BY ARCHITECT. ALL COVERPLATE5 FOR ALL DEVICES SHALL MATCH ADJACENT FINISHES. COORDINATE WITH ARCHITECT. D. WIRE I . ALL WIRE SHALL BE COPPER. 2. MINIMUM WIRE SIZE SHALL BE # 12 AWG. 3. ALL CONDUCTORS # I 0 AND SMALLER SHALL BE SOLID AND HAVE TYPE 'THHN" INSULATION. 4. CONDUCTORS LARGER THAN # 10 SHALL 5E STRANDED AND HAVE TYPE 'THW' INSULATION. E. SIGNALING SYSTEM I . PUSHBUTTON: EDWARDS # 1 7860 -8 2. TRANSFORMER: EDWARDS #596 3. BUZZER: EDWARDS # 15 -OA.1 F. AUTOMATIC TIMECLOCKS I . AS SCHEDULED, OR EQUAL. A4 ELECTRICAL SPECIFICATIONS 4 G. CONTACTORS I . AS SCHEDULED, OR EQUAL. 3.0I EXECUTION A. GENERAL I . WORK SHALL INCLUDE STARTUP OF ALL SYSTEMS, FURNISHING OF OPERATING AND MAINTENANCE INSTRUCTIONS, WARRANTY FOR ALL EQUIPMENT AND ONE YEAR GUARANTEE OF ALL WORKMANSHIP, COMMENCING ON DATE OF ACCEPTANCE BY THE TENANT. 2. WORK SHALL ALSO INCLUDE FULL ONE (1) YEAR MAINTENANCE, PARTS AND SERVICE CONTRACT FOR ALL EQUIPMENT FURNISHED UNDER THE CONTRACT. 5. SPACE PREPARATION I . IF REQUIRED, REMOVE ANY EXISTING UGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, WIRE, ETC., NOT REQUIRED FOR THE NEW WORK. ANY UNUSED FIXTURES SHALL BECOME THE PROPERTY OF THE ELECTRICAL CONTRACTOR AND SHALL BE PROMPTLY REMOVED FROM THE 51TE. C. EXISTING EQUIPMENT I . IF ANY OF THE EXISTING EQUIPMENT, INCLUDING PANELS, DISCONNECT SWITCHES, ETC., 15 ADEQUATELY SIZED AND IN GOOD OPERATING CONDITION, IT MAYBE REUSED. BASE BID SHALL INCLUDE ALL ADDITIONAL CONDUIT AND WIRING AND CONNECTIONS AS REQUIRED TO ACCOMMODATE THE INSTALLATION OF THE NEW EQUIPMENT, ETC. VERIFY SIZE AND VOLTAGE CHARACTERISTICS OF EXISTING SERVICE AT SITE. IF EXISTING SERVICE IS NOT AS INDICATED ON THE PLANS, CONTACT THE ARCHITECT FOR DISPOSITION PRIOR TO BID. 2. FIELD VERIFY THE EXACT EQUIPMENT LOCATIONS, ORIENTATIONS, SIZES, ETC. AND AVAILABIUTY FOR. REUSE OF ANY DISTRIBUTION EQUIPMENT AT THE LANDLORD'S DISTRIBUTION CENTER. TO ENSURE COMPATIBILITY, COORDINATE ANY NEW). Y REQUIRED WORK AT THE DISTRIBUTION CENTER WITH THE LANDLORD. IF ANY ISSUES ARISE WITH REGARD TO REUSE OF SERVICE AND EQUIPMENT, CONTACT ARCHITECT AND /OR ENGINEER PRIOR TO BID. BASE BID SHALL INCLUDE ALL REQUIRED WORK AT LANDLORD'S DISTRIBUTION CENTER AND SHALL BE COMPETE IN EVERY ASPECT, AS REQUIRED, TO ACCOMMODATE THIS INTENT. NO EXTRAS WILL BE ALLOWED FOR WORK NOT INCLUDED IN BASE BID. 3. FOR ANY REUSED EQUIPMENT, ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EQUIPMENT AND DtItRMINE ITS SIZE AND CONDITION PRIOR TO BID. ELECTRICAL CONTRACTOR SHALL TAKE COMPLETE RESPONSIBILITY FOR REUSED EQUIPMENT, INCLUDING: a. REFURBISHMENT OF ALL REUSED EQUIPMENT TO BRING TO LIKE NEW CONDITION, AND b. PROVIDING A I YEAR REPLACEMENT WARRANTY (INCLUDING EQUIPMENT AND INSTALLATION AND WORKMANSHIP) FOR ALL REUSED EQUIPMENT. D. TEMPORARY SERVICE 1. IF REQUIRED, PROVIDE TEMPORARY WIRING WHILE EQUIPMENT'S BEING REPLACED TO ALLOW FOR. LIGHTING AND POWER FOR CONSTRUCTION PURPOSES. ALL EXISTING EQUIPMENT SHALL REMAIN IN PLACE AS REQUIRED UNTIL THE NEW EQUIPMENT I5 READY TO BE INSTALLED. WHEN REPLACING EQUIPMENT, KEEP SHUTDOWN TIME TO A MINIMUM. E. NEW EQUIPMENT I . CONNECT ALL CIRCUITS TO PANELS P5 REQUIRED. CIRCUITS SHALL BE ARRANGED ON THE PANELS IN STRICT ACCORDANCE WITH THE NUMBERS SHOWN ON THE DRAWINGS. ANY CHANGE IN CIRCUITING DUE TO ACTUAL FIELD CONDITIONS MUST BE APPROVED BY THE ENGINEER PRIOR TO AFFECTING THE CHANGE. ANY WORK PERFORMED ASIDE FROM THAT SHOWN, INDICATED OR IMPLIED, MUST BE APPROVED BY THE PROJECT MANAGER AND /OR ENGINEER BEFORE STARTING. PANELS SHALL BE BALANCED TO WITHIN I O% BETWEEN PHASES. 2. FURNISH AND INSTALL NEW TYPEWRITTEN PANEL DIRECTORIES. 3. IDENTIFY AND LABEL ALL ELECTRICAL SERVICE INCLUDING DISCONNECT SWITCHES, PANELS, PUSHBUTTONS AND STARTERS EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATES. 4. ORDER EQUIPMENT ON A TIMELY BASIS (WITHIN 5 DAYS OF RECEIPT OF CONTRACT) TO MAINTAIN CONSTRUCTION SCHEDULE. 5. CONTRACTOR SHALL ENSURE THAT ENTIRE INSTALLATION IN ACCORDANCE WITH NEC ARTICLE 110 -26 AND THAT ALL REQUIRED OPERATING AND MAINTENANCE CLEARANCES ARE MAINTAINED AND ACCOUNTED FOR. ADJUSTMENTS TO LAYOUT SHOWN TO ACCOMMODATE CLEARANCE REQUIREMENTS SHALL BE DISCUSSED WITH ARCHITECT AND/OR ENGINEER 50 A5 TO MINIMIZE IMPACT ON OTHER SYSTEMS. G. CONTRACTOR SHALL OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE PROTECTION FOR MAIN CIRCUIT BREAKER AND BRANCH DEVICES AS REQUIRED. 7. CONNECT ALL TIMECLOCK5 A5 INDICATED AND REQUIRED. CONNECTION OF CIRCUITS TO TIMECLOCKS SHALL BE SUCH THAT STORE CAN BE CONTROLLED WITH THE INTENT SHOWN. FURNISH AND INSTALL LABELS ON SWITCHES AS REQUIRED TO IDENTIFY CIRCUITS BEING CONTROLLED. LABELS SHALL BE PERMANENTLY AFFIXED TO COVER PLATES. F. WIRING I . ALL WIRE SHALL BE IN CONDUIT AND SHALL BE CONCEALED FROM VIEW. 2. CONDUIT IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT IN UNFINISHED AREAS MAY BE EXPOSED. 3. EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIGHT LINES PARALLEL WITH OR PERPENDICULAR TO COLUMN LINES OR BEAMS AND SHALL BE SEPARATED BY AT LEAST 3" INCHES FROM DOMESTIC WATER ONES WHENEVER ALONG SIDE OR ACROSS SUCH UNES. 4. ROMEX IS NOT PERMITTED. 5. FLEXIBLE CONDUIT OR TYPE MC CABLE MAY BE USED FOR FIXTURE AND EQUIPMENT CONNECTIONS ONLY, AND WHERE 50 USED, SHALL BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. a. FLEXIBLE CONDUIT CONNECTIONS SHALL BE LIMITED TO G' -O IN LENGTH. G. CONDUIT EXPOSED TO WEATHER SHALL BE RIGID. ALL OTHER CONDUIT SHALL BE EMT. a. CONDUIT FITTINGS SHALL BE COMPRESSION OR THREADED TYPE, USE OF SET SCREW FITTINGS 15 NOT ACCEPTABLE. 7. SEAL ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS, ETC. 50 THAT THEY ARE AIR, WATER AND FIRE TIGHT. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRE PROOFED TO THE SAME OR GREATER RATING THAN THAT OF THE ASSEMBLY. WHERE CONFLICT OCCURS, NOTIFY THE ARCHITECT. 5 G. WIRING DEVICES I . VERIFY EXACT LOCATION OF OUTLETS AND DEVICES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. FURNISH AND INSTALL OUTLET BOXES, DEVICES, COVERPLATES AND FLANGES A5 REQUIRED. 2. UNLESS NOTED OTHERWISE, ALL RJ=CEPTACI F9 AND TELECOMMUNICATIONS OUTLETS SHALL BE MOUNTED AT + 18" A.F.F. TO THE CENTER OF THE DEVICE 50X. 3. UNLESS NOTED OTHERWISE, SWITCHES SHALL BE MOUNTED AT +48" A.F.F. TO THE CENTER OF THE DEVICE BOX. 4. MOUNTING HEIGHTS OF EQUIPMENT NOT SPECIFICALLY CALLED OUT MAY BE NOTED ON ARCHITECTURAL DRAWINGS - SEE ARCHITECTURAL DRAWINGS TO COORDINATE. 5. ISOLATED GROUND AND GFI RECEPTACLES SHALL BE RATED AT 20 AMPERES AND SHALL HAVE A DEDICATED INSULATED GREEN GROUND WIRE, THE GROUND WIRE SHALL BE RUN CONTINUOUS AND UNSPLICED BETWEEN THE DEVICE AND THE PANEL GROUND BUS. H. UGHTING I . SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATIONS OF ALL UGHTING FIXTURES, CEILING GRIDS, ETC. AND NOTES AND OTHER SPECIFICATION REQUIREMENTS. 2. ALL LIGHTING FIXTURES WILL BE FURNISHED BY THE OWNER UNLESS NOTED OTHERWISE. PROCURE ALL LIGHTING FIXTURES FROM OWNER AND INSTALL THEM IN THE LOCATIONS SHOWN AS REQUIRED. INSTALL ALL FIXTURES AS REQUIRED FOR A COMPLETE INSTALLATION. LEAVE PROTECTIVE COVERING/FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHTING FIXTURES IN RATED CEILING SO AS TO MAINTAIN INTEGRITY OF RATING. REPLACE ANY LAMPS THAT HAVE EXPIRED DURING CONSTRUCTION AND MAKE ALL ADJUSTMENTS TO FIXTURES FOR DIRECTION AS REQUIRED PRIOR TO COMPLETION. 3. SUPPORT ALL FIXTURES ACROSS CEIUNG TEES OR FROM STRUCTURE ABOVE. IN NO CASE SHALL CEILING TILES OR PLASTER CEILING SUPPORT ANY FIXTURES. 4. WIRE EMERGENCY BALLAST AND BATTERY LIGHTS ON SAME CIRCUIT IN AREA AND AHEAD OF LOCAL SWITCHING. 5. EXTERIOR SIGNAGE WILL BE FURNISHED AND INSTALLED BY SIGN CONTRACTOR. ELECTRICAL CONTRACTOR SHALL CONNECT SIGNS AND PROVIDE POWER AS REQUIRED FOR A COMPLETE INSTALLATION. COORDINATE THIS PORTION OF THE WORK WITH SIGN CONTRACTOR AS REQUIRED. I. SPECIALTY EQUIPMENT THE OWNER WILL FURNISH AN ELECTRIC STEAM GENERATOR FOR THIS PROJECT. THE ELECTRIC STEAM GENERATOR WILL BE INSTALLED BY THE MANUFACTURER OR REPRESENTATIVE. ELECTRICAL CONTRACTOR SHALL COORDINATE AND PERFORM THE FOLLOWING IN CONJUNCTION WITH THIS INSTALLATION: a. FURNISH AND INSTALL POWER WIRING AND CONDUIT TO ELECTRIC STEAM GENERATOR AS REQUIRED. b. DISCONNECT SWITCH SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. c. FURNISH AND INSTALL 120V POWER WRING AND CONDUIT TO ELECTRIC STEAM GENERATOR CONTROLS AS REQUIRED. d. FURNISH AND INSTALL LIGHTED PILOT SWITCH ON WALL FOR CONTROL OF TAILOR SHOP EXHAUST FAN AS REQUIRED. J. TELEPHONE I . NEW TELEPHONE TERMINAL BOARD SHALL BE 4-O" x 8' -0" PLYWOOD x 3/4" PAINTED PLYWOOD BACKBOARD, MOUNTED ON WALL, READY TO RECEIVE TELEPHONE EQUIPMENT. 2. FURNISH AND INSTALL A I " CONDUIT FOR INCOMING TELEPHONE SERVICE TO TELEPHONE BACKBOARD FROM LOCATION AS DIRECTED BY LOCAL TELEPHONE COMPANY AND /OR LANDLORD. VERIFY EXACT LOCATION AND REQUIREMENTS WITH TELEPHONE COMPANY AND LANDLORD'S REPRESENTATIVE IN FIELD. CONTACT THE TELEPHONE COMPANY TO ARRANGE FOR TELEPHONE SERVICE. FURNISH AND INSTALL ALL CONDUIT .REQUIRED K. TEMPERATURE CONTROL I . TEMPERATURE CONTROL WORK WILL BE A PART OF THE MECHANICAL CONTRACT. L. SOUND SYSTEM I . ALL SOUND SYSTEM EQUIPMENT, INCLUDING SPEAKERS AND ASSOCIATED CABUNG, IS PROVIDED AND INSTALLED BY OTHERS. M. SUBMITTALS I . SUBMIT FIVE COPIES OF SHOP DRAWINGS OF ALL EQUIPMENT FOR REVIEW BY THE ENGINEER AND ARCHITECT. ONE COPY WILL BE RETAINED FOR RECORD. ONLY FURNISH SYSTEMS, EQUIPMENT AND MATERIAL IN COMPLIANCE WITH APPROVED SHOP DRAWINGS. N. PROJECT CLOSE -OUT UPON COMPLETION OF WORK, PREPARE UGHTING AND POWER PROJECT RECORD AS- GUILTS. PRESENT THE COMPLETED DRAWINGS TO THE OWNER. AS -BUILT DRAWINGS SHALL INCLUDE ALL BRANCH CIRCUIT WORK, ANY PANELBOARD INFORMATION, FINAL SWITCHING, ETC. 2. FURNISH ALL EQUIPMENT MANUALS AND WARRANTIES TO TENANT AT THE COMPLETION OF THE PROJECT. 6 REVIEWED FOR CONELIANCE WITH PA 70- NEC JAN 0 3 2011 BUILDNG Tukwila DIVISION RECEIVED DEC 16 2010 PERMIT CENTER E D B Calvin J. Coatsworth, AIA 2495 Campus Drive Second Floor Irvine, Califomia 92612 Phone: 949. 833. 1930 Fax: 949. 833. 1140 12/13/2010 Schnackel engineers,, n New York ® Omaha ® Los Angeles 800- 581 -0963 wwwschnackel.com Jos. A. BANK ESTABLISHED 1905 SOUTHCENTER PLAZA 321 STRANDER BLVD., SUITE 321 SEATTLE, WA 98188 REVISIONS: 13 DECEMibER, 2010 ISSUED FOR JAB / LL/ PLAN REVIEW PROJECT: FILE: DATE: DRAWN BY: SCALE: GROSS AREA SALES AREA A TAILOR. /PRESS AREA FITTING AREA TOILET ROOM SHEET TITLE: ELECTRICAL SPECIFICATIONS 10191 E-701 .DWG 12/10/2010 NWM AS NOTED 4,102 sf 3,005 sf 335 sf GOO sf 162 sf E -701 UNIFORM DRAWING SYSTEM - U.S. NATIONAL CAD STANDARD VERB`