HomeMy WebLinkAboutPermit EL10-1053 - I-FLYI -FLY 349 TUKWILA PY EL1O -1053 City Of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: ht tp://www.c i. to kwil a. wa. us Parcel No.: 0223000010 Address: 301 TUKWILA PY TUKW Tenant Name: I -FLY ELECTRICAL PERMIT Permit Number: EL10 -1053 Issue Date: 01/28/2011 Permit Expires On: 07/27/2011 Owner: Name: BETA HOLDINGS LTD Address: 18827 BOTHELL WAY NE , BOTHELL WA 98011 Contact Person: Name: BRAD SHUPE Address: 4826 B ST NW, STE 101 , AUBURN WA 98007 Contractor: Name: KIRBY ELECTRIC INC Address: 4826 B ST NW, STE 101 , AUBURN WA 98001 Contractor License No: KIRBYEI077BN Phone: 253 859 -2000 Phone: 253 859 -2000 Expiration Date: 01/13/2013 DESCRIPTION OF WORK: INSTALL NEW 3000 AMP SERVICE FOR NEW ADDITION TO AN EXISTING BUILDING WITH NEW LIGHTING AND POWER AS LISTED ON PLANS. Value of Electrical Work: NRES: $198,000.00 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $3,522.75 National Electrical Code Edition: 2008 Date: Ir:d -14— t I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf•r . c of w9zky a orized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: zo a This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 ELI 0-1053 Printed: 01 -28 -2011 PERMIT CONDITIONS Permit No. EL 10 -1053 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 ELI 0-1053 Printed: 01 -28 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http.11www.ci.tukwila.wa.us • Electrical Permit No. /o ` OS3 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 301 Tukwila Pkwy Tenant Name: I -FLY King Co Assessor's Tax No.: Suite Number: New Tenant: Property Owners Name: The Annex Mailing Address: 10325 E Marginal Way S Tukwila Floor: Yes ❑..No WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Brad Shupe Day Telephone: (253) 859 -2000 Mailing Address: 4826 B St. NW Ste. 101 Auburn WA 98001 Zip E -Mail Address: brad @kirbyelectric.com City State Fax Number: (253) 859 -2363 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Kirby Electric Inc. 4826 B St NW Ste. 101 Auburn WA 98001 Contact Person: Kirby Electric Inc. E -Mail Address: brad @kirbyelectric.com Contractor Registration Number: KIRBYEI077BN City State Day Telephone: (253) 859 -2000 Fax Number: (253) 859 -2363 Expiration Date: 01/13/2011 Zip A act Valuation of Project (contractor's bid price): $ 44900"- net ,t709— Scope of Work (please provide detailed information): New 3000amp service for new addition to an existing building with new lighting and power as listed on plans Will service be altered? m Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New m Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: Puget Sound Energy ❑ Seattle City Light H:Wpplications \Forms - Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 ❑ Tenant Improvement • Temporary Service RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Date: 12/30/2010 J s £4..J 0 are Day Telephone: (253) 859 -2000 Mailing Address: 4826 B St. NW Ste. 101 Auburn 98001 IDate Application Accepted: IQr9jDf fro City H:\Applications\Forms- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 2 of 2 State Zip Staff Initials: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 0223000010 Address: 301 TUKWILA PY TUKW Suite No: Applicant: I -FLY RECEIPT Permit Number: EL10 -1053 Status: APPROVED Applied Date: 12/30/2010 Issue Date: Receipt No.: R11 -00172 Initials: WER User ID: 1655 Payment Amount: $2,818.20 Payment Date: 01/28/2011 02:19 PM Balance: $0.00 Payee: KIRBY ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 512255 2,818.20 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 2,818.20 Total: $2,818.20 doc: Receiot -06 Printed: 01 -28 -2011 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: htu,://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0223000010 Permit Number: EL10 -1053 Address: 301 TUKWILA PY TUKW Status: PENDING Suite No: Applied Date: 12/30/2010 Applicant: I -FLY Issue Date: Receipt No.: R10 -02590 Initials: User ID: Payee: JEM 1165 Payment Amount: $704.55 Payment Date: 12/30/2010 01:07 PM Balance: $2,818.20 KIRBY ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 512108 704.55 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 704.55 Total: $704.55 doc: Receiot -06 Printed: 12 -30 -2010 INSPECTION''RECORD Retain a copy with permit INSPECTION NO. al b -io5 PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (L (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: / (,` I'r Type of Inspection: Address: 311? Date Called: Special Instructions: Date Wanted:. 47 Requester: , Phone No: Approved per applicable codes. ECorrections required prior to approval. COMMENTS: 414i CA4cAnol-iB mbrbE 4:0\-t/ Inspector: Date: 46 ff ❑ REINSPECTION FEE REQUI ED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100: Call to schedule reinspection :: INSPECTION RECORD Retain a copy with permit fa() 3 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tL 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: % rt . Type of Inspection: PO 0 Address: ( Date Called: CoiPr, Special Istructions: Date Wanted:. . Imo•m,:+ 02, Requester: ele arc4 Phone No: .- 6/2,0&P t1J lit& Ct2C9 r"4 (iJ NAT, EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: 1/ ' '' 11-K- e-ra occoq - I0,1% 631‘( C1 go JS A i c 44 II l6 .. CoiPr, hior(c: - tefit- N ik , u Arip Zit■t.A Fort. r# C! B.tE-a-l1.-£ 'PLC-kV-M. u0(40(k -„&, rat. h. -T-t - t OJ ele arc4 Fivi5( 04.1-5 rok. VAN P , .- 6/2,0&P t1J lit& Ct2C9 r"4 (iJ NAT, n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /O INSPECTION RECORD Retain a copy with permit 600-1°9 INSPECTION NO. PERMIT NO. _CITY OF'TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 tr (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: ©v Address: . 301 T k. U Q Date Called: Special Instructions: Date Wanted:. Vfl 1 64 Requester: Phone No: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: V(z TpkC.4Is lAl ifc.. 'r B (( {4 eopto,,eit eakb vioi is is A7,0 L C iAJ� Inspector: tiNje ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0411 II INSPECTION RECORD ` in Retain a copy with permit W v INSPECTION NO. PERMIT NO. • CITY OF TUKWILA BUILDING DIVISIONC 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: %% % t r(-5 teott4 LA-Sty) matcmf Type of Inspection: �rtw --. ' w `tic- --C--c ID 66(.1511-- w&401-f--1Z Address:. 30 /� Py- Date Called: r - MaSkt C-®VC STD ltt44e ©d iat p Special Instructions: - 64{>J1 T- fP 5.4. lo Date Wanted:. 57 10 (a.m. pirTy Requester: jffjj Phone No: JApproved per applicable codes. Corrections required prior to approval. COMMENTS: t r(-5 teott4 LA-Sty) matcmf t.xcA -T-1 t of aitst /t oc e, a 1 5P Root- aP /. jJiTS atam k -5 --. ' w `tic- --C--c ID 66(.1511-- w&401-f--1Z (2$- 3tS'1 - #r T t. f !'l v ! tu1 s.- 1viz�� -,. r - MaSkt C-®VC STD ltt44e ©d iat p KR/ - c � tr /7 - � A 50k 044-usr: r sio F r� T; �s �P ��5 - 64{>J1 T- fP 5.4. lo Inspector: Date: t/ n REINSPECTION FEE REQUIREb. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. t INSPECTION RECORD Retain a copy with permit INSPECTION NO. 7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IL. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 • 1 Project: Type of Inspection: Address: 439/ 70k1' ran Date Called: ' Special Instructions: /j� ✓ Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. 13 gCZv /y -7 (Iv LC 1Y'7 fc 9 ) e Inspector: eWier 14ex6,07" Date: 7/ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at /6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. /H INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.- CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Fug -��s3 Project: ' f i v Type of Inspection: v 7 / Address: n ,, �J� 5 Pi. Date Called: -- Special Instructions: Date Wanted: a. m. (per= Requester: / Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (A j JG. f Date: Q 7 %Z`gf ( 1 400100\ r ■ n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit g10-ios5 PERMIT NO', CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431-2451 ft,yProject: { j' Type of Inspection: 7-0D2* Address: el ..C1 1 TN, VI • Date Called: ID e Tina - i4 tiSc..+anG�l+ r ........„ Special Instructions: Date Wanted: �7 7/ a rr p.m. Requester: s_ Phone No: LJApproved per applicable codes. aCorrections required prior to approval. COMMENTS: r 0 VII ' - CI4tIMM 44014 & F ID e Tina - i4 tiSc..+anG�l+ r To •14-G aide ( s_ Inspector: Date: 07 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 3 l3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit tho4os3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /7-- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: Address: Fri 301 /1)K- Pl. Type of Inspection: Date Called: Special Instructions: Date Wanted: Requester: loo/ 7/Z7 Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - Viif V 1 f 1/4-1. -' t» t co4IN'r5 �. vtucw) kr f JitJcf u1 ail 1 f tool what. r iso.ldOcat )RL.1 : SPfr...S 1tIok.TAr( D11-0P on) bo wak Lokt) S tV Inspector: Date: O7/271(1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. /2- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367, Permit Inspection Request Line (206) 431 -2451 Project: / ` rt.)/ Type of Inspection: --') /i/� Address: t t () Date Called: Special Instructions: Date Wanted: i� a.m. Requester: Phone No: Approved per applicable codes. ECorrections required prior to approval COMMENTS: . - gootAicliikiricrt-K er,IoK Ucjt4T+�/f. 1 Inspector: ti L1 I O V J Date: /i/� 1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be at 6300 Southcenter Blvd.. Suite 100. Call to schedule.reinspection. INSPECTION RECORD Retain a copy -with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 tho-1o53 Project: /' i L� Type of Inspection: 7003 Address:., (�4- Py . Date Called: Special Instructions: Date Wanted: m. Requester: Phone No: EIApproved per applicable codes. Corrections required prior to approval. COMMENTS: )A OXhe5f 0-001C (44445 44P &‘1‘ief\ Date: D n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be.. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.',. Inspector: INSPECTION RECORD 6110-10 Retain a copy with permit . INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 l- (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 1, rt . _ Type of Inspection: 7 Address: P, 1 301 t Ur- Py Date Called: Special Instructions: Date Wanted: �! a.m. Requester: Phone No: El Approved per applicable codes. El Corrections required prior to approval.. COMMENTS: u�w05 Zia � - ?•N\ FLeD 4 c in- Inspector: jr 8N4bc, REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection:. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36' Permit Inspection Request Line (206) 431 -2451 R^ o -1oS3 Project: f T Type of Inspection: 7003 r JAddress: D Date Called: Special Instructions: D Date Wanted: ' ''j l / a a m� o ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: n whei4/ /barithe n Inspector: ji 13(4.146, Date: 0.-1/0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD- - Retain a copy with permit- INSPECTION NO. PERMIT NO. CITY OF TUKWILA.BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 • te..(206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: / r Type of Inspection: 700/ Address: 3o '?UK Date Called: :Special Instructions: Date Wanted: Of a . Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sfr,46 CAI DVI 15 c(A -fig x1404 4 n Inspector: l 1?VNiL `� Date: Q1+ bi fit n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD kto R etain a copy with permit .� 1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 4 (206) 431 -367 Permit Inspection Request Line (206) 431-2451 Project: 1- (Li Type of Inspection: Address: 0 - t� / P. Date Called: Special Instructions: Date Wanted: dlf, a. .. t'' Requester: Phone No: aApproved per applicable codes. Corrections required prior to approval. COMMENTS: 171 c56,0c,6 7a DiscyJ,JccT` 61AW6ciDate: a /of,l:�' I n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must` be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule.reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0' CITY OF TUKWILA BUILDING DIVISION �' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: 1..... /7q � t'" Type of Inspection: 7� / Address: 7%1 Ilk- rt Date Called: Special Instructions: Date Wanted: 5� 6;1: ,11 Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Sere% CoAbiir Inspector: Date: 051/1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION- RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: / Lr � Type of Inspection: QO / Address: ,al tee. Pi- Date Called: Special Instructions: Date Wanted: . /r F m. Requester: Phone No: ElApproved per applicable codes. E Corrections required prior to approval. COMMENTS: Inspector: 664" Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: I ' � Type of Inspection: 700( Address: jj 3af —fiv�.P�- Date Called: Special Instructions: Date Wanted: �/ 7 a.m.. 1fm1 Requester: t" Phone No: E1Approved per applicable codes. E Corrections required prior to approval. COMMENTS: (0)D ()rrt ewes A ,Std CA. ,f1.0644 Date: X17 1 I n REINSPECTION FEE REQUIR D. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION NO. INSPECTION RECORD Retain a copy with permit iuo -i053 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Address: 0/ 1.* PY . Spe cial Instructions: x Type of Inspection: Date Called: a.m. 29 1 Requester: Date Wanted: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1/ Inspector: eNiii / `p Date: 009/1 ,' n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD • t Retain a copy with permit L" 0 -1053 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: /— rvi Type of Inspection: 7 Address: o i „�(� J( iit- Date Called: — 1 'i AtAtir, 5' Co -to F,6 <S8A- ab ‘$Sg Special Instructions: Date Wanted: y Z5- " . p.mmei Requester: Phone No: Approved per applicable codes. DCorrections required prior to approval. COMMENTS: ' T4 ii rr „kJ, t,e ,A,-,-,q4,,,.....,7-035 Flo/ hY ti Pts4.:� PLOP 4T7 t i'J — 1 'i AtAtir, 5' Co -to F,6 <S8A- ab ‘$Sg Date: de irl n REINSPECTION FEE REQUIRE . Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 640-10.53 CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: / — ri,,y Type of Inspection: 7005 e7 Address: ' 501 f-K- PI. Date Called: . Special Instructions: . . Date Wanted: CID; P.m. Requester: Phone No: ElApproved per applicable codes. OCorrections required prior to approval. /8 COMMENTS: Yik 60AINiT APIP 39A fni KUM," Inspector: Date: 1)3/21 REINSPECTION FEE REQUIRED. Prior to next inspectio fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 6io -4©55 PERMIT NO. Project: / 6,7 Type of Inspection: ® / Address: Pt (/. Date Called: Special Instructions: Date Wanted: 3/07 a.m. p.m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: u_e Not' pry 14 ttt3 Inspector: Zi 6/01)Afe r� n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: 0300 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director 1908 January 13, 2011 Brad Shupe Kirby Electric Inc 4826 B St NW — Suite 101 Auburn, WA 98001 RE: Correction Letter #1 Electrical Permit Application Number EL10 -1053 I -Fly — 301 Tukwila Py Dear Mr. Shupe, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. Building Department: Jim Benner at 206 - 431 -3679 if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that two (2) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, c3cut j/),_ Bill Rambo Permit Technician encl File No. ELIO -1053 W:\Permit Center \Correction Letters \2010\EL10 -1053 Correction Letter #1.DOC 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Jim Benner, Electrical Inspector Building Division Review Memo Date: January 12, 2011 Project Name: I -FLY Permit #: EL10 - 1053 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Sheet E400 Feeder Schedule 3000G. Equipment grounding conductors in parallel conduits to be 400kcmil per NEC 250.122(F) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PLANPI 1 ING SLIP ACTIVITY NUMBER: EL10 -1053 DATE: 01 -26- PROJECT NAME: I -FLY SITE ADDRESS: 301 TUKWILA PY Original Plan Submittal X Response to Correction Letter # 1 Revision # After Permit Issued Response to Incomplete Letter # DEPARTMENTS: G Oil' !vision Fire Prevention Public Works n Structural n Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 01 -27 -11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions \V Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 02 -24 -11 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 IIPPERMITCOORDCOPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL10 -1053 DATE: 12/30/10 PROJECT NAME: I -FLY SITE ADDRESS: 301 TUKWILA PY X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART ENT • ilkling 'vision ill Public Works Fire Prevention ❑ Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete „d Comments: Incomplete U DUE DATE: 01/04/11 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route. Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Nr Notation: REVIEWER'S INITIALS: DUE DATE: 02/01/11 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: I-051k Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www,ci.fulnvila.wa.us 1 REVISION SUBMITTAL 1 Revision submittals Hurst be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: C_ ( f Plan Check/Permit Number: ELI 0-1053 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: I -Fly Project Address: 301 Tukw la P l 6 '' 51u - 77� `� Contact Person: Phone Number: % Summary of Revision: ilekocridat WV OF TUKWILA X262011 PEPMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisit), Received at the City of Tukwila Permit Center by: fal'Entered in Permits Plus on 1'•J—r10'' \applications \forms - applications on line `,revision submittal Created: 8 -13 -2004 Revised. Contractors or Tradespeople P> ter Friendly Page 1 Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company KIRBY ELECTRIC INC 2538592000 4826 B St Nw Ste 101 Auburn WA 98001 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601433048 Active KIRBYEI077BN Electrical Contractor 1/15/1993 1/13/2013 General Unused License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status KIRBYE'101QE ELEC ELEC TRIC Electrical Contractor General Unused 11/5/1990 11/5/1994 Archived Master Electrician INFORMATION License KIRBYDE962LZ Name KIRBY, DOUGLAS E Status Active Business Owner Information Name Role Effective Date Expiration Date KIRBY, DOUGLAS E Cancel Date 01/01/1980 Bond Amount KIRBY, SHANNON 5 01/01/1980 70607132 KIRBY, SHANON E Agent 12/22/1992 ELECTRICAL CITATION Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 WESTERN SURETY CO 70607132 01/14/2009 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 11/05/2008 4 MERCHANTS BONDING CO (MUTUAL) WA 12415 01/14/2005 Until Cancelled 01/14/2009 $4,000.0011/04/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBIEA00522 9/3/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ENORW00271 1/27/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 ECHIR00274 9/24/2007 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 01/28/2011 NOTE: 1. THE FIXTURES SPECIFIED DO NOT SHOW ALL OF THE OPTIONS REQUIRED FOR INSTALLATION. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED .MOUNTING EQUIPMENT, FLANGE KITS, SUPPORTS, PENDANTS, ETC. REQUIRED FOR THE SPECIFIC CEILING TYPE AT NO ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND VERIFY CEILING TYPES AND MOUNTING CONDITIONS WITH ARCHITECTURAL CEILING PLANS. 2. ALL FLUORESCENT LAMPS SHALL BE 3000'K. SYMBOL LEGEND LIGHTING 2a F ---0 -1 O FLUORESCENT FIXTURE, SURFACE. "2" INDICATES CIRCUITING. "a" INDICATES SWITCHLEG FLUORESCENT STRIP FIXTURE FLUORESCENT LIGHTING FIXTURE, WALL MOUNTED FLUORESCENT LIGHTING FIXTURE, WITH EMERGENCY BATTERY BACKUP, (MINIMUM 1150 LUMEN OUTPUT). INCANDESCENT, COMPACT FLUORESCENT, OR H.I.D. DOWNLIGHT, CEILING MOUNTED. Q INCANDESCENT, COMPACT FLUORESCENT, OR H.I.D. DOWNLIGHT, CEILING MOUNTED W ITH EMERGENCY BACKUP, (MINIMUM 700 LUMEN OUTPUT). et 1-et H.I.D. FLOODLIGHT SURFACE OR WALL MOUNTED { SURFACE MOUNTED FIXTURE PENDANT MOUNTED FIXTURE PO INCANDESCENT, COMPACT FLUORESCENT OR H.I.D. LIGHTING FIXTURE, WALL MOUNTED. TRACK LIGHTING FIXTURE. EXIT LIGHT, INDICATES DIRECTION OF ARROW IN- GROUND FIXTURE. CONTROLS $v $3 $4 $LV M SINGLE POLE SWITCH - "a" INDICATES SWITCHLEG THREE WAY SWITCH FOUR WAY SWITCH MANUAL OVERRIDE SWITCH, LOW VOLTAGE MANUAL MOTOR STARTER, WITH THERMAL OVERLOAD AUTOMATIC CONTROLS 4 WALL SWITCH /OCCUPANCY SENSOR (SINGLE LOAD CONTROL) WALL SWITCH /OCCUPANCY SENSOR (DUAL LOAD CONTROL) oc CEILING MOUNTED - OCCUPANCY SENSOR, SEE DETAIL. LOW VOLTAGE / COMMUNICATIONS • WALL MOUNTED TELEPHONE OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. WALL MOUNTED DATA OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. lr COMBINATION DATA /TELEPHONE OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. POWER DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER AT +44" UNLESS NOTED OTHERWISE. SPECIAL PURPOSE RECEPTACLE, AS NOTED OO JUNCTION BOX 4O' MOTOR CONNECTION (Th, EQUIPMENT CONNECTION (INCLUDES CONDUCTORS, TERMINATIONS, GROUNDING CONDUCTOR, ETC.) DISCONNECT SWITCH OR COMBINATION MOTOR STARTER/ DISCONNECT SWITCH. SEE EQUIPMENT SCHEDULES. SWITCH SHALL INCLUDE ALL REQUIRED CONNECTIONS. (60) INDICATES SWITCH AMPERAGE/ (40) INDICATES FUSE AMPERAGE. Asa /4o CIRCUIT HOMERUN - MIN 3/4 "C -2 #12 PLUS #12GND UNLESS NOTED OTHERWISE. CONDUIT CONCEALED IN WALLS OR CEILING. — — — CONDUIT UNDER FLOOR OR UNDERGROUND. 0 CONDUIT UP /DOWN PANELBOARD CALL OUTS D FLAG NOTE EF -21 WP LIGHTING FIXTURE TYPE. SEE FIXTURE SCHEDULE. EQUIPMENT CALLOUT - SEE EQUIPMENT SCHEDULES FAULT CURRENT CALLOUT - SEE FAULT CURRENT SCHEDULE WEATHERPROOF TO (2) OVERRIDE CAT 5 SWITCHES L1 -2,4,6 L1- 1,3,5,7 ON ROOF NEW LIGHTING CONTROL PANEL WATTSTOPPER #LP8 OR EQUAL W/ 8 -1P RELAYS 1"C 10 TELEPHONE BACKBOARD FRONT ENTRY, SIGN AND BLDG. LIGHTING NEU. LOCAL SWITCHES INTERIOR LIGHTING —• 1 NEU. EMERGENCY BATTERIES Q 2 NEU. SEPARATE PERMIT REQUIRED FOR: et Mechanical ❑ Electrical d Plumbing Gas Piping City of Tukwila BUILDING DIVISION rTh LIGHTING CONTROL WI R.I NG DIAGRAM NO SCALE NEUTRAL PHASE C) NO SCALE LIGHTING FIXTURE SCHEDULE CHECK: TYPE DESCRIPTION LAMPS MANUFACTURER VA F1 2 -LAMP COMPACT FLUORESCENT PENDANT WITH 12 "DIA. FROSTED ACRYLIC REFRACTOR AND BRUSHED ANODIZED ALUMINUM TRIM. PREWIRED WITH BLACK CORD SET AND CANOPY. 2 -32W /CFL LSI ABOLITE # ATM- 32- CFL2 -277V- BRU- AF12CSL 70 F2 1 -LAMP COMPACT FLUORESCENT WALL SCONCE WITH FROSTED GLOBE AND METALLIC SILVER TRIM GUARD. PREWIRED WITH 36IN. LEADS FOR REMOTE MOUNTED BALLAST. 1 -26W /CFL LSI ABOLITE # EPT- W- 26- CFL -277V MSV- LDS96- 8 -FG 19 F3 1 -LAMP COMPACT FLUORESCENT PENDANT WITH 12 "DIA. SPUN STEEL REFLECTOR (COLOR BY ARCHITECT), WHITE GLOBE, AND WIRE GUARD. PREWIRED WITH BLACK CORD SET AND CANOPY. 1 -32W /CFL LSI ABOLITE # RD100 -32- CFL -277V- XX- CABLK -G6 -WIRE GUARD 35 F4 4FT. 2 -LAMP FLUORESCENT INDUSTRIAL STRIP WITH STEEL 8% UPLIGHT REFLECTOR AND WIRE GUARD. 2-32W/T8 METALUX # IAF- 232 -277V SERIES LSI INDUSTRIES DAYBRITE_' 62 F5 4FT. 1 -LAMP FLUORESCENT STRIP. SPECIFICATION GRADE. 1- 32W /T8 METALUX # SSF- 132 -277V SERIES LSI INDUSTRIES DAYBRITE 31 F5A 4FT. 1 -LAMP FLUORESCENT STRIP. SPECIFICATION GRADE. 120V 1-32W/T8 METALUX # SSF- 132 -120V SERIES LSI INDUSTRIES DAYBRITE, 31 F6 4FT. 2 -LAMP SURFACE FLUORESCENT FIXTURE WITH WRAPAROUND ACRYLIC LENS. SPECIFICATION GRADE. 2- 32W/T8 METALUX # WE -232 -1 -277V SERIES LSI INDUSTRIES DAYBRITE 62 F7 6 "DIA. 1 -LAMP VERTICAL COMPACT FLUORESCENT DOWNLIGHT WITH CLEAR ALZAK REFLECTOR. 1 -32W /CFL OMEGA .# S6 -32PLT SERIES PORTFOLIO 35 F8 1 -LAMP COMPACT FLUORESCENT PENDANT WITH FROSTED GLOBE AND METALLIC SILVER TRIM GUARD. PREWIRED WITH 36FT LEADS FOR REMOTE MOUNTED BALLAST. 1 -18W /CFL LSI ABOLITE # EPT -P -18- CFL -277V MSV- LDS96 -8 -FG 19 F9 FLIGHT CHAMBER LIGHTING F1d 1 -LAMP INCANDESCENT LINE VOLTAGE TRACK HEAD ON SURFACE MOUNTED SINGLE CIRCUIT TRACK. RING SHAPED LAMPHOLER ON ADJUSTABLE YOKE MOUNT. FINISH AS SPECIFIED BY ARCHITECT. LENGTH OF TRACK AS NOTED ON DRAWING. 2 HEADS PER 4' -O" 1 -75W PAR30 LIGHTOLIER # 6282 HEAD # 6000 BASIC LYTESPAN TRACK 75 F11 4FT 1 -LAMP FLUORESCENT WITH VAPOR -TIGHT ENCLOSURE. WALL MOUNTED 1- 32W/T8 METALUX #VT1- 132 -PCR -277V SERIES LSI INDUSTRIES DAYBRITE 31 F12 1 -LAMP METAL HALIDE WALLWASHER, WITH MEDIUM NARROW WASH DISTRIBUTION, CAST ALUMINUM HOUSING AND SURFACE MOUNTED ON ROOF. FINISH AS SPECIFIED BY ARCHITECT. UL LISTED FOR WET LOCATION. 1 -150W /CMH INSIGHT # M02- 150CMH- MW -SM -2 170 F13 (2) FLOODLIGHTS MOUNTED ON SINGLE 12" ARM. (1) 150W MH UP WALL WASHER, WITH MEDIUM NARROW DISTRIBUTION AND (1) 39W MH DOWN WITH ASYMMETRICAL DISTRIBUTION. CAST ALUMINUM HOUSING. FINISH AS SPECIFIED BY ARCHITECT. UL LISTED FOR WET LOCATION. 1 -150W /CMH 1 -39W /CMH INSIGHT # M02- 150CMH -MW & # MQ1- 39CMH- AS4 /WM2 215 F14 6 "DIA. 1 -LAMP METAL HALIDE IN- GROUND UPLIGHT WITH BRASS TRIM AND NARROW FLOOD OPTICS. MOUNTED FLUSH IN CONCRETE. UL LISTED FOR WET LOCATION. 1 -39W /CMH KIM # LTV769 SERIES 45 F15 6 "DIA. 1 -LAMP METAL HALIDE IN- GROUND UPLIGHT WITH BRASS TRIM AND NARROW FLOOD OPTICS. MOUNTED FLUSH IN CONCRETE. UL LISTED FOR WET LOCATION. 1 -20W /CMH KIM # LTV769 SERIES 25 F16 NOT USED F17 (21 -LAMP COMPACT FLUORESCENT WALL SCONCE WITH 18 W x10 "H x 9 "D RECTANGULAR ALUMINUM HOUSING, GASKETED TEMPERED GLASS LENS AND MEDIUM FORWARD THROW OPTICS. BRONZE FINISH. 2-32W/CFL GREENBRIAR #GBWS SERIES FINELITE 70 X DIE -CAST ALUMINUM LED EXIT SIGN, UNIVERSAL MOUNTING, WHITE HOUSING, STENCIL FACE, GREEN LETTERS, DUAL VOLTAGE, NI-CAD BATTER WITH SELF - DIAGNOSTIC ELECTRONICS. LED CHLORIDE # CX SERIES 3 NOTE: 1. THE FIXTURES SPECIFIED DO NOT SHOW ALL OF THE OPTIONS REQUIRED FOR INSTALLATION. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED .MOUNTING EQUIPMENT, FLANGE KITS, SUPPORTS, PENDANTS, ETC. REQUIRED FOR THE SPECIFIC CEILING TYPE AT NO ADDITIONAL COST. CONTRACTOR SHALL COORDINATE AND VERIFY CEILING TYPES AND MOUNTING CONDITIONS WITH ARCHITECTURAL CEILING PLANS. 2. ALL FLUORESCENT LAMPS SHALL BE 3000'K. SYMBOL LEGEND LIGHTING 2a F ---0 -1 O FLUORESCENT FIXTURE, SURFACE. "2" INDICATES CIRCUITING. "a" INDICATES SWITCHLEG FLUORESCENT STRIP FIXTURE FLUORESCENT LIGHTING FIXTURE, WALL MOUNTED FLUORESCENT LIGHTING FIXTURE, WITH EMERGENCY BATTERY BACKUP, (MINIMUM 1150 LUMEN OUTPUT). INCANDESCENT, COMPACT FLUORESCENT, OR H.I.D. DOWNLIGHT, CEILING MOUNTED. Q INCANDESCENT, COMPACT FLUORESCENT, OR H.I.D. DOWNLIGHT, CEILING MOUNTED W ITH EMERGENCY BACKUP, (MINIMUM 700 LUMEN OUTPUT). et 1-et H.I.D. FLOODLIGHT SURFACE OR WALL MOUNTED { SURFACE MOUNTED FIXTURE PENDANT MOUNTED FIXTURE PO INCANDESCENT, COMPACT FLUORESCENT OR H.I.D. LIGHTING FIXTURE, WALL MOUNTED. TRACK LIGHTING FIXTURE. EXIT LIGHT, INDICATES DIRECTION OF ARROW IN- GROUND FIXTURE. CONTROLS $v $3 $4 $LV M SINGLE POLE SWITCH - "a" INDICATES SWITCHLEG THREE WAY SWITCH FOUR WAY SWITCH MANUAL OVERRIDE SWITCH, LOW VOLTAGE MANUAL MOTOR STARTER, WITH THERMAL OVERLOAD AUTOMATIC CONTROLS 4 WALL SWITCH /OCCUPANCY SENSOR (SINGLE LOAD CONTROL) WALL SWITCH /OCCUPANCY SENSOR (DUAL LOAD CONTROL) oc CEILING MOUNTED - OCCUPANCY SENSOR, SEE DETAIL. LOW VOLTAGE / COMMUNICATIONS • WALL MOUNTED TELEPHONE OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. WALL MOUNTED DATA OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. lr COMBINATION DATA /TELEPHONE OUTLET - PROVIDE BACKBOX AND STUB 3/4 "C. UP TO SERVER ROOM. POWER DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE, MOUNTED ABOVE COUNTER AT +44" UNLESS NOTED OTHERWISE. SPECIAL PURPOSE RECEPTACLE, AS NOTED OO JUNCTION BOX 4O' MOTOR CONNECTION (Th, EQUIPMENT CONNECTION (INCLUDES CONDUCTORS, TERMINATIONS, GROUNDING CONDUCTOR, ETC.) DISCONNECT SWITCH OR COMBINATION MOTOR STARTER/ DISCONNECT SWITCH. SEE EQUIPMENT SCHEDULES. SWITCH SHALL INCLUDE ALL REQUIRED CONNECTIONS. (60) INDICATES SWITCH AMPERAGE/ (40) INDICATES FUSE AMPERAGE. Asa /4o CIRCUIT HOMERUN - MIN 3/4 "C -2 #12 PLUS #12GND UNLESS NOTED OTHERWISE. CONDUIT CONCEALED IN WALLS OR CEILING. — — — CONDUIT UNDER FLOOR OR UNDERGROUND. 0 CONDUIT UP /DOWN PANELBOARD CALL OUTS D FLAG NOTE EF -21 WP LIGHTING FIXTURE TYPE. SEE FIXTURE SCHEDULE. EQUIPMENT CALLOUT - SEE EQUIPMENT SCHEDULES FAULT CURRENT CALLOUT - SEE FAULT CURRENT SCHEDULE WEATHERPROOF TO (2) OVERRIDE CAT 5 SWITCHES L1 -2,4,6 L1- 1,3,5,7 ON ROOF NEW LIGHTING CONTROL PANEL WATTSTOPPER #LP8 OR EQUAL W/ 8 -1P RELAYS 1"C 10 TELEPHONE BACKBOARD FRONT ENTRY, SIGN AND BLDG. LIGHTING NEU. LOCAL SWITCHES INTERIOR LIGHTING —• 1 NEU. EMERGENCY BATTERIES Q 2 NEU. SEPARATE PERMIT REQUIRED FOR: et Mechanical ❑ Electrical d Plumbing Gas Piping City of Tukwila BUILDING DIVISION rTh LIGHTING CONTROL WI R.I NG DIAGRAM NO SCALE NEUTRAL PHASE C) NO SCALE SHEET INDEX E100 ELECTRICAL COVER SHEET E200 ELECTRICAL SITE PLAN E300 PLENUM LEVEL ELECTRICAL PLAN E305 GROUND LEVEL LIGHTING AND POWER PLANS E310 SECOND LEVEL LIGHTING AND POWER PLANS E315 LOW ROOF LEVEL ELECTRICAL PLAN E320 SERVICE LEVEL ELECTRICAL PLAN E400 ELECTRICAL ONE -LINE DIAGRAM E401 SKYDIVING EQUIPMENT WIRING DIAGRAM REVIEWED .FOH COMPLIANCE WITH NFPA 70 - NEC JAN 2 7 2011 City o . j !la BUILDING (VISION FILE COPY Permit No., Ek-Ao Plan review approval is subject to errors and omissions. Approval of construction documents dons not authorize the violation of any adopted code or ordinance. Receipt of approved Field ,► • : 1 ., ,1 : Is acknowledged: By . 4 : #'- l Date: Arr City Of 1i.kwila BUILDING DIVISION RELAY POWER PACK 17- LOW VOLTAGE CABLE FOR MANUFACTURER —(- REQUIREMENTS TO NEXT REMOTE SENSOR IF REQUIRED 24VDC REMOTE SENSOR LIGHTS - CONTROL GROUP (a,b,c) OVERRIDE (OFF) SWITCH LOCATED IN SAME SPACE AS LUMINARIES PROVIDE ONLY IF INDICATED ON PLANS. OCCUPANCY SENSOR WIRING DIAGRAM REVISIONS No granges shall b dae mm to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. duo r 821z Pi • w w u 'o • is MS sl w o `U CITYEOCFETUI(NALA DEC ? 0 2010 PERMIT CENTER 0 DRAWN BY: BN/SAS CHECK: GENERAL NOTES 1. NOT ALL CONDUIT AND CONDUCTORS FOR BRANCH CIRCUITS HAVE BEEN SHOWN. IT IS THE PLOT DATE: RESPONSIBILITY OF THE CONTRACTOR TO INSTALL REQUIRED CONDUIT AND WIRE FOR A JOB NO COMPLETE INSTALLATION. HOMERUN FROM FIRST DEVICE TO PANEL SHALL BE INDICATED ON AS -BUILT DRAWINGS. 2. CONTRACTOR SHALL PROVIDE REQUIRED UNSWITCHED CIRCUIT TO ALL EXIT AND EGRESS LIGHTING. 3. ALL EXTERIOR LIGHTING CIRCUITS SHALL BE #10 Cu AND ROUTED THROUGH LIGHTING CONTROL PANEL. 4. CONTRACTOR SHALL COORDINATE HVAC EQUIPMENT REQUIREMENTS (LOCATION, CONNECTION TYPE, CONTROLS, LOAD, VOLTAGE, ETC.) WITH HVAC CONTRACTOR PRIOR TO EQUIPMENT ORDERING AND ROUGH -IN. 5. CONTRACTOR SHALL PROVIDE ALL CONDUIT AND 120V CONTROL WIRING FOR HVAC EQUIPMENT. COORDINATE WITH HVAC CONTRACTOR. 6. CONTRACTOR SHALL COORDINATE SKYVENTURE EQUIPMENT REQUIREMENTS (LOCATION, CONNECTION TYPE, CONTROLS, LOAD, VOLTAGE, ETC.) WITH MANUFACTURER PRIOR TO ROUGH -IN. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR INCOMING POWER UTILITY. COORDINATE WITH PSE AND PROVIDE AS REQUIRED. COORDINATION TO BE DONE PRIOR TO BID. 8. COORDINATE DEVICE HEIGHTS AND LOCATIONS WITH FURNITURE LAYOUT AND ARCHITECTURAL ELEVATIONS, PRIOR TO ROUGH -IN. 9. THE FIRE ALARM SYSTEM. SHALL BE BIDDER - DESIGN. PROVIDE COMPLETE SYSTEM WITH DEVICES AS REQUIRED BY STATE AND LOCAL CODES AND AHJ. REFER TO SPECIFICATION SECTION 28 31 00. SHEET INDEX E100 ELECTRICAL COVER SHEET E200 ELECTRICAL SITE PLAN E300 PLENUM LEVEL ELECTRICAL PLAN E305 GROUND LEVEL LIGHTING AND POWER PLANS E310 SECOND LEVEL LIGHTING AND POWER PLANS E315 LOW ROOF LEVEL ELECTRICAL PLAN E320 SERVICE LEVEL ELECTRICAL PLAN E400 ELECTRICAL ONE -LINE DIAGRAM E401 SKYDIVING EQUIPMENT WIRING DIAGRAM REVIEWED .FOH COMPLIANCE WITH NFPA 70 - NEC JAN 2 7 2011 City o . j !la BUILDING (VISION FILE COPY Permit No., Ek-Ao Plan review approval is subject to errors and omissions. Approval of construction documents dons not authorize the violation of any adopted code or ordinance. Receipt of approved Field ,► • : 1 ., ,1 : Is acknowledged: By . 4 : #'- l Date: Arr City Of 1i.kwila BUILDING DIVISION RELAY POWER PACK 17- LOW VOLTAGE CABLE FOR MANUFACTURER —(- REQUIREMENTS TO NEXT REMOTE SENSOR IF REQUIRED 24VDC REMOTE SENSOR LIGHTS - CONTROL GROUP (a,b,c) OVERRIDE (OFF) SWITCH LOCATED IN SAME SPACE AS LUMINARIES PROVIDE ONLY IF INDICATED ON PLANS. OCCUPANCY SENSOR WIRING DIAGRAM REVISIONS No granges shall b dae mm to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. duo r 821z Pi • w w u 'o • is MS sl w o `U CITYEOCFETUI(NALA DEC ? 0 2010 PERMIT CENTER 0 DRAWN BY: BN/SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO 1 009 Jlf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL: 425 216.0318 FAX: 425 216.0329 W p4, oga 01 1.110124E21 M O ca SHEET: E 100 OF: SHEETS 063 1- _,,." -- — EXISTING UTILITY CO. TRANSFORMER lX15TIRG I3CLDING 5. 'RICA_ ROOM EXISTING PSE PRIMARY VAUL: EXISTING BUILDING TEL. TERM. BOARD NEW FIRE ALARM CONTROL PANEL NEW PRIMARY SERVICE< NEW UTILITY CO. TRANSFORMER C NEW SECONDARY SERVICE - SEE ONE -LINE DIAGRAM — NEW MDB rim elect - roan MEI C ELECTRICAL SITE FLAN I i II = 20LO" 1 V_ 1 1 0 L• � o — 4, a, N 2` to 4) VP Ex. i~ t0 '� in ch oo c'1 `a� °a tea GENERAL NOTES 1. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. 2. COORDINATE ELECTRICAL SERVICE REQUIREMENTS WITH POTELCO /PSE - JAMES ROBBINS (james.robbinsepse.corn) AND PROVIDE ALL WORK, MATERIAL, ETC. AS REQUIRED. 3. PROVIDE SERVICE IDENTIFICATION PLACARDS IDENTIFYING ADDITIONAL BUILDING SERVICES, AS REQUIRED BY NEC AND LOCAL AHJ. 4. COORDINATE TEMPORARY POWER OUTAGE TO EXISTING TENANTS WITH UTILITY COMPANY AND GENERAL CONTRACTOR. PROVIDE TEMPORARY SERVICE (POWER, TELEPHONE, CABLE) FOR EXISTING TENANTS AS REQUIRED DURING SWITCHOVER. REVIEWED FOH COMPLIANCE WITH NFPA70 -NEC JAN 2 7 2011 City of Tukwila BUILDING DIVISION DETAIL NOTES NEW UTILITY COMPANY PRIMARY SERVICE. COORDINATE REQUIREMENTS WITH POTELCO AND PROVIDE AS REQUIRED. TRENCHING /BACKFILL BY CONTRACTOR. CONDUCTORS, CONDUIT, TRANSFORMER, AND PAD /VAULT BY UTILITY COMPANY. PROVIDE NEW FIRE ALARM CONTROL PANEL. REPLACE EXISTING PANEL AND ASSOCIATED DEVICES IN ELECTRICAL ROOM WITH NEW. MAKE REQUIRED CONNECTIONS TO EXISTING BUILDING DEVICES, AS WELL AS NEW TENANT SPACE DEVICES. ELIO - 1053 PERMIT SET 10/13/2010 DESCRIPTION DRAWN BY: BN /SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 Jf Jensen Fey ARCHITECTURE& PLANNING 7 730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216 0318 FAX: 425.216D329 7:4 z W U C/D r:4 0 0 g (/) w (2) rri J ll—Hii to BOTHELL, WA. 9801 1 SHEET: E200 OF: SHEETS \\ REVIEWED � FOR H COMPLIANCE 70 - NEC JAN 2'7 2011 City wTukila BUILDING DIVISION GENERAL NOTES t RECEPTACLES IN PLENUM LEVEL SHALL HAVE "WEATHERPROOF" ENCLOSURE, GFCI TYPE. P1 -7 L1 -1 -L P1-7 L1 -1 (F11 ;P1 -7 L1 -1 M IA/P-21 L1 -1 El P1 -7 WP L1 -1 P1 -7 L1 -1 wPtil t y PLENUM LEVEL - ELECTRICAL PLAN Q___) 1 /8" = 1 '-0" ELIO 1053 E,:=1 p6?t ECEIV E D CITY R OF TUtA DEC 2 0 2010 PERMIT CENTER DESCRIPTION DRAWN BY: MECHANICAL EQUIPMENT SCHEDULE CHECK: TYPE DESCRIPTION VOLTAGE LOAD MOCP CIRCUIT CONDUCTORS WP -1 DEWATERING PUMP - 1 120V /1PH 1 /3HP P1 -9 3/4 "C,2 #12 & 1 #12G WP -2 DEWATERING PUMP - 2 120V /1PH 1 /3HP P1 -9 3/4 "C,2 #12 & 1 #12G \\ REVIEWED � FOR H COMPLIANCE 70 - NEC JAN 2'7 2011 City wTukila BUILDING DIVISION GENERAL NOTES t RECEPTACLES IN PLENUM LEVEL SHALL HAVE "WEATHERPROOF" ENCLOSURE, GFCI TYPE. P1 -7 L1 -1 -L P1-7 L1 -1 (F11 ;P1 -7 L1 -1 M IA/P-21 L1 -1 El P1 -7 WP L1 -1 P1 -7 L1 -1 wPtil t y PLENUM LEVEL - ELECTRICAL PLAN Q___) 1 /8" = 1 '-0" ELIO 1053 E,:=1 p6?t ECEIV E D CITY R OF TUtA DEC 2 0 2010 PERMIT CENTER DESCRIPTION DRAWN BY: BN /SAS CHECK: BAA ti NOTES: PLOT DATE: 10 -13 -10 JOB NO: i 1009 Jlf Jensen Fey ARCHITECTURE & PLANNING 7 730 LEARY WAY N E REDMOND, WA 98052 TEL 425 216 0318 FAX 425.216.0329 47:4 _ O f1 m_1 V All dr- 3 (7) 1-2'ill p4 p o o � m� o�� z �r p 112 J° ' o c%) oq SHEET: E300 OF: SHEETS L1 -3 - —L-1 -3 L1 -3 L1 -3 ''knctrlcal roo"r [ i._,1 11-6 r'ocr F7771 C.' , 11111M71111111 L1 -36' ®6 L0 1 -6 L1-6 L® GROUND LEVEL -- LIGHTING PLAN /8" = -Q11 DETAIL NOTES 3/4 "CONDUIT TO SERVER ROOM. 1 "CONDUIT TO SERVER ROOM. 45A/3P SHUNT -TRIP BREAKER FOR ELEVATOR. PROVIDE FEEDER TO MDB (SEE ONE -LINE SHEET E400) LIGHTING CONTROL SYSTEM OVERRIDE SWITCH. SEE WIRING DIAGRAM SHEET E100. PROVIDE LOCAL DISCONNECTING MEANS FOR CONTROL PANELS AND CONDUIT /WIRE TO WP- 1 /WP -2 AS REQUIRED BY MECHANICAL CONTRACTOR. • } 1. 7: -fi' ,411,1 . LIGHTING CONTROLS 1 WH -01 2 "C TO FACP IN EXISTING BUILDING ELEC. RM. SEE SHEET E200 WH -1 I PULL SECT. DIST. DP1/DP2 CONTROL PANELS (P1 -17) ELEVATOR CONTROLLER 1 "C, 4 #6 & 1 110 GND CAB LTG. EL -2 TU -T SEE ELEV. WIRING DIAGRAM SHEET E401 REVIEWED FClH CONFPA7�OCNEGTH JAN 27 2011 City ty ot.Tukwila BUILDING (VISION . FIRE ALARM ANNUNCIATOR ii oir to;,+;:cr- MECHANICAL EQUIPMENT SCHEDULE CHECK: TYPE DESCRIPTION VOLTAGE LOAD MOCP CIRCUIT CONDUCTORS WH -01 FAN FORCED WALL HEATER 120V /1PH 1500W COFFEE P1 -25 Cc P1 -19 y REFRIG. P1 -21 3/4 "C,2#12 & 1 #12G WH -1 WATER HEATER 208V /1PH 4500W P1-23 P1 -40,42 3/4 "C,3 #10 & 1 #10G EU -1 FAN COIL UNIT 120V /1PH 114W EL -4 3/4 "C,2 #12 & 1 #12G • } 1. 7: -fi' ,411,1 . LIGHTING CONTROLS 1 WH -01 2 "C TO FACP IN EXISTING BUILDING ELEC. RM. SEE SHEET E200 WH -1 I PULL SECT. DIST. DP1/DP2 CONTROL PANELS (P1 -17) ELEVATOR CONTROLLER 1 "C, 4 #6 & 1 110 GND CAB LTG. EL -2 TU -T SEE ELEV. WIRING DIAGRAM SHEET E401 REVIEWED FClH CONFPA7�OCNEGTH JAN 27 2011 City ty ot.Tukwila BUILDING (VISION . FIRE ALARM ANNUNCIATOR ii oir to;,+;:cr- WARR ING CHECK: BAA DRAWER P1 -39,41 ,>----- , ' 3/4 "C,3 #12 & 1 VERIFY RECEPT MICROWAVE P1 -27 �\ #12G NOTES: FFE7 T C1.1E\ 10 -13 -10 33 1 rT P1 -27 P1 -19 a P1 -19- COFFEE P1 -25 Cc P1 -19 y REFRIG. -, 1 ID L. -- — +s4� \r L J '11C 't raj P1-23 i' - aI P1 -19 - II `ESP- 400HP ORS EO- {2)- -MO ON SERVICE - LEVEL. SEE SHEET ,E320: __ / \\ 7 / \ lr cc,,, t! -- '`� , \ et 61, lr- \ iaii 1 1 ilk 1 :1H 1 -1 ,r_ 1 . opp, • FE'-ETER. -- 1), /P1 -11 1- - al a_ j- r o fFI_ (i! , — P = - 1 -13 L1 1 --=-:::::_.-------...R.1-13 P1 -11 P1 -15 P1 -1 � +.tom +84 "' k284 L J G1r t:-.)0 /'ni f ,M `.. UP TO-{2) -400HP MOTORS -( ON SERVICE LEVEL SEE SHEET E320. 4x4 x3/4 PLYWOOD TELEPHONE TERMINAL BOARD #6CU, GND GROUND LEVEL - POWER PLAN 1" C FROM TENANT TTB TO BUILDING TELE. TERM. BOARD IN EXISTING ELEC. RM. SEE SHEET E200. ELIo (053 /&II = 1 1 -0rr crtvoTitn DEC ? 0 2010 PERMIT CENTER H fg H DESCRIPTION Q 2 DRAWN BY: BN /SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 Jlf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425 216 0318 FAX: 425.216.0329 U) z I 1 w w Q U � � (/) All • cn mw �C Q ,„ z� CD `I J tgrilz z ijd8- 01 2C) r Dz H_ c5,om_ SrIEET: E305 OF: SHEETS F6 L1 -3` women's roorn it L1 / 1101.11.0 F3 .,mew F7 L11--5 L1-5 5 F7 L1 -5 101 �O N ' L1 -5 NN ,-, ! !► a [— I[--1 or d ;7 ,l L1-5/ .j 0 to dL d d �,- �L1' -5 Fg Lt L1 -5 L17:-5 (j ,.. 11 =5 --= - L —5 `1AL-' F9 I_ 1 lill �/ i.�r 1I -,: r 1 -5 L1— h iIiV v r IR! L1-5 F3 d L1 -5 • d NN 4► L1 -1 rPtirn <:]v toover L X11 •]1111011C L1 -5 Fort COOtr 2 MEM MEC 0 • L1 -5 11•1111i MINK1]IMIDi rt. room ® L1 -5 0 111•OR MINIID1 L1 -5 -- -'`L1 -5 ILA ,,.L„ F6 L1 -5 11•1110] L1 -5 L1 -5 9, d 4D L1 -5 F3 r. d L1 -5 L1 -5 L1 -5 Ll -5d`t d L1 -5 Sjit d •0 L1 -5 • d `N ,Nt1 5 `N F10 0 1 -5 MI • ■■ L d 0 L1 -5 41)'e F8 L- 0 r L1 5 } L1 -5 Li- e) 11 9io -3a e I,1r;r`"v5 � d 0 /L1 -5 •a 0 FAA tl` 0 F4 L1 -5 0 L1-5 NM* L i.. r•,-;\ SECOND LEVEL - LIGHTING PLAN /SII = I I -0II DETAIL NOTES 3/4 "C TO SERVER ROOM. NOT USED. INSIDE AND OUTSIDE TEMPERATURE SENSORS. VERIFY LOCATIONS. ENTRY AND EXIT DOOR ACTUATORS. CONTROL PROVIDED AND INSTALLED BY EQUIPMENT MANUFACTURER. 120V POWER BY ELECTRICAL CONTRACTOR. VERIFY EXACT LOCATIONS. ADDITIONAL FIELD CONNECTIONS TO EQUIPMENT MANUFACTURER INSTALLED EQUIPMENT MAY BE REQUIRED. COORDINATE WITH EQUIPMENT MANUFACTURER. roorl J Ill:n'S r o::'t11 I i1Ct1 room i.- REFRIG. P1 -12 MICROWAVE P1 -14 MICROWAVE P�1 fi 1LI 1' -LN P1-18 i1A1 (,,: -.,,Y di iG rill-) P1-18 t 3111 room REVIEWED FOft COMPLIANCE WITH NFPA 7Q -NEC JAN 272011 8�1o Tukwila NQ DIVISION :om EP1 -20 KN.1 1-12 � P1(tb - 20 P1 -2 STACKED P1 -3 WASHER /DRYER '-'-----. P2 -32,34 3/4 "C,3 #1O & 1 #10G SECOND LEVEL - POWER PLAN LI 1 /8" = I I -OII I 0 5 3 e"NA C40F1UKVNLA DEC ? 0 2010 PERMIT CENTER 4-1 DESCRIPTION az 2 DRAWN BY: MECHANICAL EQUIPMENT SCHEDULE CHECK: TYPE DESCRIPTION VOLTAGE LOAD MOCP CIRCUIT CONDUCTORS WH -01 FAN FORCED WALL HEATER 120V /1PH 1500W P1 -31 3/4 "C,2 #12 & 1 #12G RTU -4 ROOF TOP UNIT -4 480V/3PH 10.4MCA 15.0A L1- 31,33,35 3/4 "C,4 #12 & 1 #12G roorl J Ill:n'S r o::'t11 I i1Ct1 room i.- REFRIG. P1 -12 MICROWAVE P1 -14 MICROWAVE P�1 fi 1LI 1' -LN P1-18 i1A1 (,,: -.,,Y di iG rill-) P1-18 t 3111 room REVIEWED FOft COMPLIANCE WITH NFPA 7Q -NEC JAN 272011 8�1o Tukwila NQ DIVISION :om EP1 -20 KN.1 1-12 � P1(tb - 20 P1 -2 STACKED P1 -3 WASHER /DRYER '-'-----. P2 -32,34 3/4 "C,3 #1O & 1 #10G SECOND LEVEL - POWER PLAN LI 1 /8" = I I -OII I 0 5 3 e"NA C40F1UKVNLA DEC ? 0 2010 PERMIT CENTER 4-1 DESCRIPTION az 2 DRAWN BY: BN/SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1 009 Jlf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216.0318 FM: 425.216.0329 ca `/' dui P4 b> z cf) I91LI < O @) Z�I p o �- loDuN .._I SHEET: E310 OF: SHEETS LRUVER ACTUA IOR _- ._._.- 2HR,480V 3/4 C,3 #12 & 1'#r2G L UVER ACTURATOR F�ANEL\ }N ELEC. 112. TYPICAL< OF (8) r LOUVER A TUATOR BRAKE 3/4 "C, 2 #1 TO A TUMOR &TOR -VFO -- LOUVER FEEDBACK POT 3/4 "C, 2 #12 T AOTUATOR MOT VFD \CL LL-4 s' 0" CU -1 rC ;C?t L--- -I L1 -4� -o" L1-4N, MECHANICAL EQUIPMENT SCHEDULE CHECK: TYPE DESCRIPTION VOLTAGE LOAD MOCP CIRCUIT CONDUCTORS RTU -01 ROOFTOP UNIT - 01 480V,3PH 14.6MCA 15.OA L1- 37,39,41 3/4 "C,4 #12 & 1 #12G RTU -02 ROOFTOP UNIT - 02 480V,3PH 21.1MCA 25.OA L1- 38,40,42 3/4 "C,4 #10 & 1 #10G RTU -03 ROOFTOP UNIT - 03 480V,3PH 11.8MCA 15.OA L1- 32,34,36 3/4 "C,4 #12 & 1 #12G EF -01 ROOF MOUNTED UTILITY FAN - 01 120V,1PH 1 /6HP P1 -29 3/4 "C,2 #12 & 1 #12G EF -02 ROOF MOUNTED UTILITY FAN - 02 120V.1PH 1 /4HP P1 -29 3/4 "C.2 #12 & 1 #12G CU -1 ROOF MOUNTED CONDENSING UNIT 120V,1PH 14.0MCA EL -4 3/4 "C,2 #12 & 1 #12G 111 LRUVER ACTUA IOR _- ._._.- 2HR,480V 3/4 C,3 #12 & 1'#r2G L UVER ACTURATOR F�ANEL\ }N ELEC. 112. TYPICAL< OF (8) r LOUVER A TUATOR BRAKE 3/4 "C, 2 #1 TO A TUMOR &TOR -VFO -- LOUVER FEEDBACK POT 3/4 "C, 2 #12 T AOTUATOR MOT VFD \CL LL-4 s' 0" CU -1 rC ;C?t L--- -I L1 -4� -o" L1-4N, +23' -0" +23' -0" L1 -4 L1 -4 1 +2S -0- L1 -4 +2 L1 -4 23' -O" L1 -4 LOW ROOf LEVEL - ELECTRICAL FLAN L1 -4 23' -O" 1/8" = 1 1 -0rr REVIEWED FU,H COMP LANCE WITH A 70 - NEC JAN 2 7 2011 City of Tukwila BUILDING DIVISION "'Ad wiZ\ O PIP ELIO- 165 3 H H P1 0 0 0 oL 2 DRAWN BY: • CHECK: ' 30/6 1 Q d o L1 -1 _0 - O 30%6 30/6 ■ - -' 0 Q L1 -1 0 O '30/6. NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 U wP 1 -� 1 EF( -02 r;,,, < 1 1 "-- RTU -02 1 3030:: S 111 ■ 30/20 YIP ^^ , `---- _ FO c RTU -1 - —_,,.. s RTU -03 - EF -01 �■ 30 20- --- q wr inPtb P1 -3 -30/6 O L0 1-1 ,,, 39/s 0 O ,,U O O - 30/6 O O - - -- - -- -' .,„ +23' -0" +23' -0" L1 -4 L1 -4 1 +2S -0- L1 -4 +2 L1 -4 23' -O" L1 -4 LOW ROOf LEVEL - ELECTRICAL FLAN L1 -4 23' -O" 1/8" = 1 1 -0rr REVIEWED FU,H COMP LANCE WITH A 70 - NEC JAN 2 7 2011 City of Tukwila BUILDING DIVISION "'Ad wiZ\ O PIP ELIO- 165 3 H H P1 0 0 0 oL 2 DRAWN BY: BN/SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 U Jlf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216 0318 FM 425.2160329 SHEET: E315 OF: SHEETS DETAIL NOTES MAKE CONNECTION TO INTERNALLY ILLUMINATED SIGN. VERIFY EXACT LOCATION WITH ARCHITECTURAL ELEVATIONS. INSTALL HATCH SENSORS PER MANUFACTURER'S REQUIREMENTS AND MAKE CONNECTION TO REMOTE I/O PANEL. INTERNALLY CONDUITS DOWN Tp IN ELECTRIC ROOM SEE SHEET E305. VFD'S 113. • F5 L1 -1 0 INTEINALLY ILLUMINATED SIGN L1 -1 L1 -1 P1 -5 et L1 -1 A. L1 -1 1 \ P -8 2 VPC%& C TO PLC ON ROOF. 'SEE E3:5 & E4 11-1 LINK STAGING SHEETS 1. SERVICE LEVEL - ELECTRICAL PLAN CONDUITS DOWN TO VFD'S IN ELECTRIC ROOM 113. SEE SHEET E305. REMOTE I/O PA PROVIDED BY EQUIPMENT MANUFACTURER INSTALLED BY ELECT. CONTRACTOR. VERIFY EXACT LOCATION. I/8" = 11-0" REVIEWED rUit COMPLIANCE WITH NFPA 70 - NEC JAN 2 7 2011 City o'Tukwila BUILDING DIVI, ION OLIO-1053 RECEIV CITY CF MA LA DEC ? 0' 2010 PERMIT CENTER 2 DRAWN BY: BN /SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 Jf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216 0318 FAX 425.216.0329 W a � f.j , `�` C� LLB, icr> O mw O va a dw Ra z = LLI H<c4u F-1 M O rn _ LLJ SHEET: E320 OF: SHEETS Panel L1 . 1 PANEL SCHEDLLE (PROJECT: I FLY - INDOOR SKYDIVING #10051 277/480V, 3PH, 4W 100A Bus M.L.O. SURFACE WALL MOUNTED 17-Jan-11 Ckt. No. Description / Location Load (VA) Load Type C.B. Amp C.B. Pole Phase C.B. Amp C.B. Pole Load (VA) Load Type .Description / Location Ckt, No. 1 LTG - PLENUM, SERVICE & TOWERS 930 1 20 1 A 20 1 500 L LTG - SIGN 2 3 LTG - GROUND LEVEL 2,877 1 20 1 B 20 1 2,560 L LTG - TOWER FLOODLIGHTS 4 5 LTG - SECOND LEVEL 2,683 1 20 1 C 20 1 510 L LTG - FRONT ENTRY. REAR 6 7 LTG - EXIT STAIR & ELEC. ROOMS 809 1 20 1 A 20 1 f ,V SPARE 8 9 SPARE 0 20 20 1 B 20 1 WW1 3,000 SPARE 10 11 SPARE 17,439 20 20 1 C 20 1 LM SPACE SPARE 12 13 SPARE 117,501 470,004 20 i A 20 1 4,500 100% SPARE 14 15 SPARE Continuous General Load 0 20 1 B 20 1 125% 375 SPARE 16 17 SPARE 1,410,012 VA 2,130,679 VA 20 1 C 20 1 R RECEPT - LOUNGE & HALL SPARE 18 19 SPARE H 20 20 3 A 60 3 R RECEPT - TEAM ROOMS SPARE 20 21 -- K 20 - - 0 - - R RECEPT - UT1L,STOR,CLASS,BREAK - 22 23 -- K 20 - - C - - R RECEPT - MAIN HALL -- 24 25 SPARE K 20 20 3 A 1 1,080 R RECEPT - PARTY ROOMS SPACE 26 27 -- K 20 - A B 1 900 R RECEPT- RESTROOMS,HALL JAN SPACE 28 29 - -- K 20 - - c 1 1,000 C SERVER ROOM SPACE 30 31 RTU4 M M 20 3 A 20 3 3266 M RTU-03 32 33 -- H M - - 8 - - 3266 M - 34 35 -- L M - - c - - 3,266 M - 36 37 RTtl -01 4,041 M 20 3 A 30 3 4,041 M RTi -02 38 39 -- 4:041 M - - 13 - 2,500 4,041 M - 40 41 -- 4,041 M - - C - - 4,041 M -- 42 Total Connected Load: Ph A 13,587 VA 49 A Total Connected Load: Ph B 16,785 VA 61 A Total Connected Load: Ph C 14,541 VA 52 A Total Connected Load: 44.9 KVA Total Demand Load; 47.6 KVA 54.1 AMPS 57.4 AMPS Connected Striated Total Demand Demand Loads Loads (S) Loads Factor Load G General (Non-Continuous) 0 0 100% 0 L Lighting 40,869 10,869 125% 13,586 R Receptacles - to 10 KVA 0 0 100% 0 over 10 KVA 0 50% 0 K Kitchen o 0 100% 0 H Heating 0 0 100% 0 M Motors 34,044 34,044 100% 34,044 LM Largest Motor 0 0 125% 0 WH Water Heater 0 0 100% 0 C Continuous General Load 0 0 125% 0 44,913 VA 0 VA 44,913 VA 47,830 VA 22,000AIC Accessories: - - Panel EL (ELEVATOR RM.) 1 PANEL SCHEDULE (PROJECT: I FLY - INDOOR SKYDIVING ##10051 120/208V, 1PH, 3W 100A Bus M.L.O. SURFACE WALL MOUNTED 17- Jan -11 Ckt. Na Description / Location Load (VA) Load Type C.B. Amp C.B. Pole Phase CB. Amp C.B. Pole Load (VA) Load Type Description / Location Ckt. No. 1 ELEV. PIT LTG & REC 242 G 20 1 A 20 1 500 L CAB LTG 2 3 ELEV. MAGI RM. LTG & REC 242 G 20 . 1 B 20 1 1,880 M EU -1 & CU -1 4 6 SPARE 0 125% 20 1 A 10,000 10,000 100% 10,000 SPACE 6 7 SPARE 720 3,680 20 1 B 0 50% K f ,V 8 9 SPARE 9,194 0 20 1 A 0 3,000 3,000 WW1 3,000 10 11 SPARE Motors 17,439 20 1 B 1,961,699 965,904 100% LM SPACE 12 Total Connected Load: Ph A 742 VA 6 A Total Connected Load: Ph B 1,922 VA 16 A Total Connected Load: 2.7 KVA Total Demand Load: 2.8 KVA 12.8 AMPS 13.4 AMPS Connected Subfed Total Demand Demand Loads Loads (S) Loads Factor Load G General (Non - Continuous) 484 484 100% 484 L Lighting 500 500 125% 625 R Receptaces - to 10 KVA 0 0 100% 0 over 10 KVA 0 50% 0 K IGtchen 0 0 65% 0 H Heating 0 0 100% 0 M Motors 1,680 1,680 100% 1,680 LM Largest Motor 0 0 125% 0 WH Water Heater 0 0 100% 0 c Continuous General Load 0 0 125% 0 2,664 VA U VA 2,664 VA 2,789 VA 10,000AIC Accessories: 117,501 470,004 Panel P1 1 PANEL SCHEDULE (PROJECT: I FLY - INDOOR SKYDIVING #10051 120/208V, 3PH, 4W 225A Bus 150AM.C.B. SURFACE WALL MOUNTED 17- tan -11 Ckt. Description / Load Load C.B. C.B. 'L' Length MAIN DIST. BOARD LOAD CALCULATIONS LOAD CALCULATIONS Load Load Description 1 Ckt. No. Location (VA) Type Amp Pole Connected Loads Subfed Loads (S) Total Demand Loads Fodor Demand Load Subfed Loads (S) Total Demand Loads Factor G General (Non - Continuous) 0 5,734 5,734 100% 5,734 0 100% 1 Lighting 0 11,969 11,969 125% 14,961 0 125% R Receptacles - to 10 KVA 0 10,000 10,000 100% 10,000 0 100% 0 over 10 KVA 720 3,680 3,680 50% 1,840 0 50% K Kitchen 0 9,194 9,194 100% 9,194 0 100% H Heating 0 3,000 3,000 100% 3,000 0 100% M Motors 17,439 1,944,260 1,961,699 100% 1,961,699 965,904 100% LM Largest Motor 0 470,004 470,004 25% 117,501 470,004 25% WH Water Heater 0 4,500 4,500 100% 4,500 0 100% C Continuous General Load 0 1,800 t800 125% 2,250 300 125% 375 14 17,439 VA 2,464,141 VA 2,481,580 VA 1,410,012 VA 2,130,679 VA = 2,566 Amps 1,083,780 VA = 1,305 Amps R RECEPT - LOUNGE & HALL 16 17 WALL HEATER WH -1 1,500 Panel P1 1 PANEL SCHEDULE (PROJECT: I FLY - INDOOR SKYDIVING #10051 120/208V, 3PH, 4W 225A Bus 150AM.C.B. SURFACE WALL MOUNTED 17- tan -11 Ckt. Description / Load Load C.B. C.B. 'L' Length SWDD SD LOAD CALCULATIONS Load Load Description 1 Ckt. No. Location (VA) Type Amp Pole Phase Amp Pole Connected Loads Subfed Loads (S) Total Demand Loads Factor Demand Load 1 RECEPT.-ELECT, HALL G General (Non-Continuous) 0 0 0 100% 0 Lighting L L Lighting 0 0 0 125% 0 1 8 R Receptacles - to 10 KVA 0 0 0 100% 0 RECEPT - SERVICE LEVEL 720 R over 10 KVA 1 0 0 50% 0 Kitchen - K Kitchen 0 0 0 100% 0 A 20 H Heating 0 0 0 100% 0 1,728 M M Motors 940,008 25.896 965,904 100% 965,904 PLC 10 IM Largest Motor 470,004 0 470,004 25% 117,501 20 1 WH Water Heater 0 0 0 100% 0 R 20 C Continuous General Load 0 300 300 125% 375 14 15 RECEPT - RRS, JAN & MTG RMS 1,260 1,410,012 VA 26,196 VA 1,436,208 VA B 1,083,780 VA = 1,305 Amps R RECEPT - LOUNGE & HALL 16 17 WALL HEATER WH -1 1,500 H 20 1 Panel P1 1 PANEL SCHEDULE (PROJECT: I FLY - INDOOR SKYDIVING #10051 120/208V, 3PH, 4W 225A Bus 150AM.C.B. SURFACE WALL MOUNTED 17- tan -11 Ckt. Description / Load Load C.B. C.B. 'L' Length C.B. C.B. Load Load Description 1 Ckt. No. Location (VA) Type Amp Pole Phase Amp Pole (VA) Type Location No. 1 RECEPT.-ELECT, HALL 720 R 20 1 A 30 3 Lighting L SURGE SUPPRESSION NOTE 1 2 3 RECEPT - ROOF & TOWERS 1,080 R 20 1 8 - - 100% 0 - 4 5 RECEPT - SERVICE LEVEL 720 R 20 1 C - - K Kitchen - 6 7 RECEPT - PLENUM 1.080 R 20 1 A 20 1 250 C REMOTE I/O PANEL 8 9 DEWATER PUMPS 1& 2 1,728 M 20 1 B 20 1 250 C PLC 10 11 RECEPT - GR. LEVEL OFFICES & RECE 1,080 R 20 1 C 20 1 1,200 K REFRIG & REC - BREAKROOM 12 13 RECEPT - LOBBY, HALL 1,080 R 20 1 A 20 1 900 K MICROWAVE - BREAKROOM 14 15 RECEPT - RRS, JAN & MTG RMS 1,260 R 20 1 B 20 1 900 R RECEPT - LOUNGE & HALL 16 17 WALL HEATER WH -1 1,500 H 20 1 C 20 1 1.260 R RECEPT - TEAM ROOMS 18 19 MICROWAVE - PREP 105 1,200 K 20 1 A 20 1 1,260 R RECEPT - UT1L,STOR,CLASS,BREAK 20 21 KIT REC & TOASTER OVEN - PREP 105 1,000 K 20 1 B 20 1 1260 R RECEPT - MAIN HALL 22 23 REFRIG - PREP 105 850 K 20 1 C 20 1 1,080 R RECEPT - PARTY ROOMS 24 25 COFFEE - PREP 105 1,596 K 20 1 A 20 1 900 R RECEPT- RESTROOMS,HALL JAN 26 27 DISHWASHER - PREP 105 1,100 K 20 1 B 20 1 1,000 C SERVER ROOM 28 29 EF -01, 02 & 03 896 M 20 1 C 20 1 250 G FACP 30 31 WH -01 SECOND FLOOR LEVEL 1,500 H 20 1 A 30 2 742 S PANEL EL 32 33 LTG - TRACK LTG & CHAMBER SPOTS 6.00 L 20 1 B - - 1,922 S - 34 35 SPARE 20 1 C 30 2 2,500 G STACKED WASHER/DRYER 36 37 SPARE 20 1 A - - 2,500 G - 38 39 WARMING DRAWERS 674 K 20 2 B 30 2 2250 WH WATER HEATER WH -1 40 41 -- 674 K - - C - - 2.250 WH - 42 Total Connected Load: Ph A 7,176 VA 26 A Total Connected Load: Ph B 7,442 VA 27 A Total Connected Load: Ph C 5,720 VA 21 A Total Connected Load: 20.3 KVA Total Demand Load: 39.1 KVA 56.5 AMPS 108.6 AMPS Connected Suhfed Total Demand Demand Loads Loads (3) Loads Factor Load 10,000AIC G General (Non- Continuous) 5,250 484 5,734 100% 5,734 1 Lighting 600 500 1,100 125% 1,375 R Receptacles -to 10 KVA 13,680 0 10,000 100% 10,000 Accessories: over 10 KVA 0 3,680 50% 1,840 K Kitchen 9,194 0 9,194 70% 6,436 H Heating 3,000 0 3,000 100% 3,000 M Motors 2,624 1,680 4,304 100% 4,304 LM Largest Motor 0 0 0 125% 0 WH Water Heater 4,500 0 4;500 100% 4,500 C Continuous General Load 1,500 0 1,500 125% 1,875 40,348 VA 2,664 VA 43,012 VA 39,064 VA NOTES: PROVIDE LEVITON 52000 SERIES SURGE SUPPRESSION IN ADJACENT ENCLOSURE. METAL PIPE (1) #3/0 CU BONDING CONDUCTOR (1) #3/0 CU GROUNDING ELECTRODE CONDUCTOR TO MDB (1) #3/0 CU. (TYP.) CONCRETE ENCASED ELECTRODE - MIN. 20' LONG #4 BARE CU IN CONCRETE FOOTING /FOUNDATION 20' -0" 10' x 3/4" COPPER CLAD STEEL GROUND ROD - TYPICAL FOR (2) STRUCTURAL STEEL GROUNDING INSTALLATION SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250 (MINIMUM OF 3 GROUNDING ELECTRODES ARE REQUIRED) GROUNDING DETAIL SCALE: NONE MAKE CONNECTION TO BUILDING STEEL TYP. 4 FANS { HL A C T COMPLIANCE FPA 70 - NEC TO UTILITY CO. PRIMARY VAULT SEE SITE PLAN. JAN 2 7 2011 City of Tukwila BUILQING DIVISION NEW UTILITY CO. PAD MOUNTED TRANSFORMER L FAN 1 400HP FAULT CURRENT CALCULATIONS CHECK: TAG PNL Avail. Upstream Current (lsca) g a N co Conduit •c' Value 'L' Length SWBD. SPA LOAD CALCULATIONS 'ELL` Vdtag e if 1.732xLxlsca 'M' 1 Avail Short Circuit Current KVA Z' ImP d. Y' Isc(p)x480x1.732xZ 'M' 1 Avail Short Circuit Current NxCxaL 1 +1 Connected Loads Subfed Loads(S) Connected Loads Subfed Loads (S) Total Demand Loads Factor Demand Load G General (Non-Continuous) 0 General (Non - Continuous) 0 100% 0 100% 0 L Lighting L Lighting 0 125% 0 125% 0 R Receptades - to 10 KVA R Receptacles -to 10 KVA 0 100% 0 100% 0 over 10 KVA over 10 KVA 0 50% 0 50% 0 K Kitchen K Kitchen 0 100% 0 100% 0 H Heating H Heating 0 100% 0 100% 0 M Motors M Motors 940,008 100% 940,008 100% 940,008 IM Largest Motor LM Largest Motor 470,004 125% 470,004 25% 117,501 WH Water Heater WH WaterHeater 0 100% 0 100% 0 C Continuous General Load C Continuous General Load 0 125% 0 125% 0 0.056 0.947 13,098 VA 0 VA 1,410,012 VA 0 VA 1,410,012 VA = 1,057,509 VA = 1,273 Amps 600 Steel 22,965 20 4 480 0.027 0.973 34,002 MAKE CONNECTION TO BUILDING STEEL TYP. 4 FANS { HL A C T COMPLIANCE FPA 70 - NEC TO UTILITY CO. PRIMARY VAULT SEE SITE PLAN. JAN 2 7 2011 City of Tukwila BUILQING DIVISION NEW UTILITY CO. PAD MOUNTED TRANSFORMER L FAN 1 400HP FAULT CURRENT CALCULATIONS CHECK: TAG PNL Avail. Upstream Current (lsca) g a N co Conduit •c' Value 'L' Length LOUVER PANELS LOAD CALCULATIONS 'ELL` Vdtag e if 1.732xLxlsca 'M' 1 Avail Short Circuit Current KVA Z' ImP d. Y' Isc(p)x480x1.732xZ 'M' 1 Avail Short Circuit Current NxCxaL 1 +1 Connected Loads Subfed Loads(S) Total Demand Loads Factor Demand Load 56,738 1-1/2"C G General (Non-Continuous) 0 0 100% 0 600 > L Lighting 0 1680 9 125% 0 500 PVC R Receptades - to 10 KVA 0 480 0 100% 0 over 10 KVA 0 50% 0 Steel 981 K Kitchen 0 9.246 0 100% 0 H Heating 0 LI 0 100% 0 2,425 25 M Motors 12,948 0.330 12,948 100% 12,948 IM Largest Motor 0 54,644 0 125% 0 25 1 WH Water Heater 0 9,070 0 100% 0 C Continuous General Load 150 500 150 125% 188 8 208 0.056 0.947 13,098 VA 0 VA 13,098 VA 0,481 13,136 VA = 16 Amps SW BD 34,935 600 Steel 22,965 20 4 480 0.027 MAKE CONNECTION TO BUILDING STEEL TYP. 4 FANS { HL A C T COMPLIANCE FPA 70 - NEC TO UTILITY CO. PRIMARY VAULT SEE SITE PLAN. JAN 2 7 2011 City of Tukwila BUILQING DIVISION NEW UTILITY CO. PAD MOUNTED TRANSFORMER L FAN 1 400HP FAULT CURRENT CALCULATIONS CHECK: TAG PNL Avail. Upstream Current (lsca) g a N co Conduit •c' Value 'L' Length 'N' Parallel Runs 'ELL` Vdtag e if 1.732xLxlsca 'M' 1 Avail Short Circuit Current KVA Z' ImP d. Y' Isc(p)x480x1.732xZ 'M' 1 Avail Short Circuit Current NxCxaL 1 +1 100,000xKVA 1 +f XFMR 56,738 1-1/2"C 150 150 > (2) 4 #350kCMIL, 1 #0 GND (2) 3 "C 620 600 > (4) 4#600kCMIL, 1 #4/0 GND (4) 4 "C 1680 (1600 MDP 56,738 500 PVC 26,706 40 8 480 0.038 0.963 54,644 ELEV 54,644 10 Steel 981 46 1 480 9.246 0.098 5,333 LI 54,644 6 Steel 2,425 25 1 480 2.033 0.330 18,018 XFMR 54,644 10 Steel 981 25 1 480 5.025 0.166 9,070 FILTER 54,644 500 Steel 22,185 22 8 208 0.056 0.947 51,726 1700 1.9 0,481 0.675 34,935 SW BD 34,935 600 Steel 22,965 20 4 480 0.027 0.973 34,002 MAKE CONNECTION TO BUILDING STEEL TYP. 4 FANS { HL A C T COMPLIANCE FPA 70 - NEC TO UTILITY CO. PRIMARY VAULT SEE SITE PLAN. JAN 2 7 2011 City of Tukwila BUILQING DIVISION NEW UTILITY CO. PAD MOUNTED TRANSFORMER L FAN 1 400HP FAN 2 400HP 0 O co 600/600 1 VFD 1 I 1 VFD 2 I L - -J L - -J O O CD 0 0 CD ro ( Q CD C I -- - - - - -4 -- ELECTRICAL SWITCHBOARD A 1600A, 480/277V, 3PH, 4W 35,000AIC X <3000> X 0 O (0 r L FAN 4 400HP { 600/600 600 /600 0 0 (D I VFD 3 1 I VFD 4 I L__J L - -J 0 0 CD O O (D DETAIL NOTES: PROVIDED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE BROADBAND HARMONIC FILTER, MIRUS # AUHF- 2300 - 480- 60 -D -E1, IN NEMA 3R ENCLOSURE. FILTER SHALL BE IEEE 519 COMPLIANT FOR VOLTAGE AND CURRENT DISTORTION. CONTACT MICHAEL BOND OF PERFORMANCE POWER CONCEPTS, BELLEVUE, WA. PH. 425.638.0340 OR EMAIL mbond . pcwa.com. LOUVER ACTUATOR PANELS 22,000AIC 22,000AIC - --1 IA,B,C,D1 1 E,F,G,H 1 I_ -J L_ _J 0 r7 0 Iv) v Q� Q� CD c \I 5 I UD -41- --- - -3 - - -- - - -4- - O O (0 x FILTER ■x 0 0 0 0 ro ELECTRICAL SWITCHBOARD B 1600A, 480/277V, 3PH, 4W 35,000AIC O LD 0 w J W 0' O O 0 r7 ( 1 1 PANEL P1 C 150A M.B. M 0 (0 45KVA 480- 120/208V STEPDOWN TRANFORMER Cl- M Q O t) fie 0_ M • O N O U Q CL 1 0_ u, 0_ O 0 MAIN DIST. BOARD (MDB) 3000A, 480/277V, 3PH, 4W 65,000AIC SEE GROUND = ROD DETAIL C�� ELECTRICAL ONE -LINE DIAGRAM } No SCALE CORRECTION Q RECEIVED: . .,r JAN 2 6 2011 c� I PERMIT CENTER H ELto 1053 O O N O PERMIT COMMENTS 01 -17 -I1 DRAWN BY: FEEDER SCHEDULE CHECK: TAG FEEDER (Cu) CONDUIT AMPERAGE (75'C) 4 #10, 410 GND 1"C 35 30 > 4#6, 1 #10 GND 1 "C 65 60 > 4 #2, 1#6 GND 1-1/2"C 115 100 ) 4#1/0 CU, 1#6 CU GND 1-1/2"C 150 150 > (2) 4 #350kCMIL, 1 #0 GND (2) 3 "C 620 600 > (4) 4#600kCMIL, 1 #4/0 GND (4) 4 "C 1680 (1600 (8) 4 #500kCMIL, 1#400kCMIL GND (8) 4 "C 3040 <3000G> <3000> (8) 4 #500kCMIL (8) 4 "C 3040 FAN 2 400HP 0 O co 600/600 1 VFD 1 I 1 VFD 2 I L - -J L - -J O O CD 0 0 CD ro ( Q CD C I -- - - - - -4 -- ELECTRICAL SWITCHBOARD A 1600A, 480/277V, 3PH, 4W 35,000AIC X <3000> X 0 O (0 r L FAN 4 400HP { 600/600 600 /600 0 0 (D I VFD 3 1 I VFD 4 I L__J L - -J 0 0 CD O O (D DETAIL NOTES: PROVIDED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR. PROVIDE BROADBAND HARMONIC FILTER, MIRUS # AUHF- 2300 - 480- 60 -D -E1, IN NEMA 3R ENCLOSURE. FILTER SHALL BE IEEE 519 COMPLIANT FOR VOLTAGE AND CURRENT DISTORTION. CONTACT MICHAEL BOND OF PERFORMANCE POWER CONCEPTS, BELLEVUE, WA. PH. 425.638.0340 OR EMAIL mbond . pcwa.com. LOUVER ACTUATOR PANELS 22,000AIC 22,000AIC - --1 IA,B,C,D1 1 E,F,G,H 1 I_ -J L_ _J 0 r7 0 Iv) v Q� Q� CD c \I 5 I UD -41- --- - -3 - - -- - - -4- - O O (0 x FILTER ■x 0 0 0 0 ro ELECTRICAL SWITCHBOARD B 1600A, 480/277V, 3PH, 4W 35,000AIC O LD 0 w J W 0' O O 0 r7 ( 1 1 PANEL P1 C 150A M.B. M 0 (0 45KVA 480- 120/208V STEPDOWN TRANFORMER Cl- M Q O t) fie 0_ M • O N O U Q CL 1 0_ u, 0_ O 0 MAIN DIST. BOARD (MDB) 3000A, 480/277V, 3PH, 4W 65,000AIC SEE GROUND = ROD DETAIL C�� ELECTRICAL ONE -LINE DIAGRAM } No SCALE CORRECTION Q RECEIVED: . .,r JAN 2 6 2011 c� I PERMIT CENTER H ELto 1053 O O N O PERMIT COMMENTS 01 -17 -I1 DRAWN BY: BN /SAS CHECK: BAA NOTES: PLOT DATE: 11 -08 -10 JOB NO: 1009 Jlf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216.0318 FAX: 425.216.0329 SHEET: E400 Or: SHEETS ELEV. MACH. RM. ELEVATOR DETIAL NOTES: PROVIDE TELEPHONE LINE TO ELEVATOR AND DIAL TELEPHONE IN ELEVATOR MACHINE ROOM. MIN. 1 "C. TO MAIN TELEPHONE TERMINAL BOARD. LOCATE PIT LIGHTS AND RECEPTACLES AS RECOMMENDED BY ELEVATOR CONTRACTOR. PIT LIGHTS TO BE NEMA 4X. PROVIDE HEAT DETECTORS IN ELEVATOR MACHINE ROOM AND ELEVATOR SHAFT-MAXIMUM 18" FROM SPRINKLER HEAD. LABEL "ELEVATOR CONTROL ONLY - DO NOT TEST ". INTERCONNECT SHUNT TRIP DEVICE SUPPLYING ELEVATOR POWER WITH THESE DETECTORS. CONNECT FOR ELEVATOR RECALL. MOUNT ELEVATOR MAIN DISCONNECT IMMEDIATELY ADJACENT TO DOOR. PROVIDE CONTROL TRANSFORMER TO SUPPLY POWER TO HEAT DETECTORS & SHUNT TRIP, NEMA 1 ENCLOSURE. PROVIDE AUX, DRY CONTACTS FOR AUTOMATIC BACKDOWN FEATURE. COORDINATE REQUIREMENTS WITH ELEVATOR SUPPLIER. CAB LIGHTS AND FAN, EXACT LOCATION TO BE COORDINATED WITH ELEVATOR SUPPLIER. PROVIDE LOCKABLE TYPE DISCONNECTING MEANS IN MACHINE ROOM. LOUVER DAMPER. MAKE CONNECTION TO FIRE ALARM CONTROL PANEL TO OPEN ON ALARM, PER WAC 296 -96- 02570. COORDINATE LOCATION AND REQUIREMENTS WITH GENERAL CONTRACTOR. CNTRL. TRANSFORMER WITH PRI /SEC FUSING (480 OR 208) / 120V, 250VA SHUNT -TRIP DEVICE 3 -PH PWR r ELEV. PIT TOP OF SHAFT DAMPER M ELEVATOR MAIN DISCONNECT AUX DRY CONTACTS ELEVATOR CONTROLLER ELEV. LOBBY (TYPICAL) 1 ID DICATED 1 OV CIRCUIT 1 TO FIRE ALARM PANEL ELEVATOR RECALL DED. 120V CKT. TO TTB ELEVATOR POWER $ EIRE ALARM WIRING DIAGRAM NO SCALE O W . ;" 8,0060 1 0 - cT vp o� a, do -1I- 0 oh DESCRIPTION CONDUCTOR LEGEND 24VDC MULTICONDUCTOR CABLE (ANIXTER P/N 323 - 321 -2001 OR EQUAL), INSTALL.IN CONDUIT, AND- TERMINATE PER EQUIPMENT MANUFACTURER'S DIRECTION. 24VDC MULTICONDUCTOR CABLE (ANIXTER P/N 6G- 1801 -6 OR EQUAL), INSTALL IN CONDUIT AND TERMINATE PER EQUIPMENT MANUFACTURER'S DIRECTION. 24VDC SHIELDED TWISTED 2 CONDUCTOR CABLE, BELDEN # 9497 OR EQUAL. INSTALL IN CONDUIT AND TERMINATE PER EQUIPMENT MANUFACTURER'S DIRECTION. 24VDC SHIELDED TWISTED 3 CONDUCTOR CABLE, BELDEN # 9498 OR EQUAL. INSTALL IN CONDUIT AND TERMINATE PER EQUIPMENT MANUFACTURER'S DIRECTION. CC LINK CABLE, BELDEN #1349A, 5- CONDUCTOR DATA CABLE. INSTALL._IN: CONDUIT AND TERMINATE PER EQUIPMENT MANUFACTURER'S DIRECTION. 24VDC CABLE, INSTALLED BY EQUIPMENT MANUFACTURER. SOME FIELD TERMINATIONS MAY BE REQUIRED, PER EQUIPMENT MANUFACTURER'S DIRECTION. 480V POWER. REFER TO ONE -LINE DIAGRAM AND PLAN DRAWINGS FOR SIZE. 120V POWER. REFER TO PLAN DRAWINGS FOR SIZE. DETAIL NOTES: PROVIDED BY EQUIPMENT MANUFACTURER, INSTALLED BY ELECTRICAL CONTRACTOR. SEE PLAN DRAWINGS FOR LOCATIONS. 120V POWER 120V POWER 120V POWER ❑ HATCH E SENSORS 0 INSIDE TEMP SENSOR REMOTE I/O TYP. HATCH SENSORS OUTSIDE TEMP (T SENSOR ``�� FACP TEL. TERM. BD. PROVIDED AND INSTALLED BY EQUIPMENT MANUFACTURER. SOME FIELD TERMINATIONS MAY BE REQUIRED. REFER TO EQUIPMENT MANUFACTURER DIRECTIONS. GENERAL NOTES: 1. ALL CONDUCTORS SHALL BE RUN IN CONDUIT, UNLESS OTHERWISE NOTED. CONDUIT BY CONTRACTOR. 2. ALL 24VDC, CC LINK AND POWER CONDUCTORS SHALL BE RUN IN SEPARATE CONDUITS WITH 24IN. SEPARATION. 3. ALL 24VDC CONDUCTORS SHALL BE TERMINATED PER EQUIPMENT MANUFACTURER'S DIRECTION. ENT. DOOR J -BOX ENT. DOOR J -BOX PLC VIBRATION 0 SENSORS ❑ 0 ■ TYP. VIBRATION SENSORS FAN 1 400HP L WIRELESS ROUTER CONSOLE 0 VFD 1 1 CD FAN 2 400HP //(7)/ I I 0 VFD 2 FAN 3 FAN 4 400HP 400HP /cy I N I N V V ACTUATOR A BRAKE 2HP POT 11 V VFD 3 11 v VFD 4 11 SWITCHBOARD A SBA 480V POWER SEE ONE -LINE DIAGRAM CDSKYDIVING EQUIPMENT WIRING DIAGRAM NO SCALE 11 El 11 11 11 1. SWITCHBOARD B SBB ACTUATOR B BRAKE 2HP POT v ACTUATOR C ACTUATOR 0 BRAKE 2HP POT BRAKE 2HP POT 11 LOUVER ACTUATOR PANELS A,B,C,D 1 1 1 480V POWER SEE ONE -LINE DIAGRAM r C 0 E 11 0 \O` LOUVER ACTUATOR PANELS E,F,G,H BRAKE 2HP POT BRAKE 2HP POT ACTUATOR E ACTUATOR F n 11 0 11 COMPLIANCE W TH NFPA 70 -NEC JAN 2 7 2011 City of Tukwila BUILDING DIVISION 0 ' BRAKE 2HP POT BRAKE 2HP POT ACTUATOR G ACTUATOR H ELiO 1053 cry RE 0CEIV T 1 U uA DEC 2 0 2010 PERMIT CENTER H H w Q a 5 DRAWN BY: BN /SAS CHECK: BAA NOTES: PLOT DATE: 10 -13 -10 JOB NO: 1009 Jf Jensen Fey ARCHITECTURE & PLANNING 7730 LEARY WAY NE REDMOND, WA 98052 TEL 425.216.0318 FAX: 425.216.0329 C. 4:--r =1.'1 Q 4 c.) r( W r cio _i P4 0 0@)P-1 v QU 4 FFii '61 I4 0") CD �w =mow F�rr� RI �- Mo m _w SHEEP: 4oJ OP: SHEETS