Permit EL11-0030 - SABEY CORPORATION - 5201B
SABEY 5201B 3355 S 120 PL EL1 1 -0030 Parcel No.: Address: Tenant Name: City t.f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 1023049082 3355 S 120 PL TUKW SABEY 5201B ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL11 -0030 02/10/2011 08/09/2011 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: KURT PREISSLER Phone: 206 948 -8362 Address: 5614 7 AV S , SEATTLE WA 98108 Contractor: Name: VECA ELECTRIC CO INC Address: 5617 7TH AVE S , SEATTLE WA 98108 Contractor License No: VECAECI542MU Phone: 206 860 -0231 Expiration Date: 10/31/2011 DESCRIPTION OF WORK: ARCHITECTURAL LIGHTING UPGRADES TO 2ND FLOOR LIGHTING. REPLACE EXISTING HALLWAY FIXTURES WITH NEW STYLE IN THE HALLWAY OUTSIDE SUITE 5201B. Value of Electrical Work: NRES: $10,000.00 Fees Collected: RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature. $330.63 National Electrical Code Edition: 2008 Date: d1._{ (0 I hereby certify that I have read and exa fined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie, wit , whether specified herein or not. The granting of this permit does not pre - e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. Signature: Date: L / - Print Name: P r ) C _-T C\'! f''^- + 1 / " 17' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL1 1-0030 Printed: 02 -10 -2011 PERMIT CONDITIONS Permit No. EL11 -0030 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL11 -0030 Printed: 02 -10 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. �UI-OD3� (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan revieW. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3355 South 120th Place, Tukwila , WA Tenant Name: Sabey Data Center Property Owners Name: Sabey Corporation King Co Assessor's Tax No.: \02-1,011— 11: U2-- Suite Number: 5201B Floor: New Tenant: ❑ Yes ® .. No Mailing Address: 12201 TUKWILA INTL BLVD 4TH FL Tukwila, WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Kurt Preissler Mailing Address: 5614 7th Ave S Seattle, WA 98108 E -Mail Address: Kurt.Preissler@VECA.com Day Telephone: 2_0_6 =9 4 8 - 8 3 6 2 city state Fax Number: 206- 763 -0505 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA Electric Co. INC Mailing Address: 5614 7th Ave S Contact Person: Paul Masterjohn E -Mail Address: Paul.masterjohn @veca.com Contractor Registration Number: VECAECI542MU Seattle City WA 98108 Zip state Day Telephone: 206- 679 -5733 Fax Number: 206- 763 -0505 Expiration Date: 10/31/10 Valuation of Project (contractor's bid price): $ 10,000 Scope of Work (please provide detailed information): Architectural lighting upgrades to 2nd floor lighting. Replace existing hallway fixtures with new style in the halway outside of suite 5201B. Will service be altered? ❑ Yes Type of Use: Commerical El No Adding more than 50 amps? ❑ Yes ® No Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy j Seattle City Light ❑ Service Change ❑ Fire Alarm H:Wpplications \Forms - Applications On Line \4 -2007 - Electrical Permit Application.doc bh ❑ Remodel ® Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) - -- $55 =00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) - $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PE ,RY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE ,: ' ELECTRICAL CONTRACTOR: Signature: Print Name: Kurt Preissler Mailing Address: 5614 7th Ave S IDate Application Accepted: III tv Date: I t i 4i. 11 Day Telephone: 206 -948 -8362 Seattle WA 98108 City State Zip Date Application Expires: 011 1 Q I [ Staff Initials: HAApplicationsTomu- Applications Chi Line \4 =2007 = Electrical Permit Application.dnc bh Page 2 of 2 • • �J�.`N1LA wqs City of Tukwila �;; ,Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049082 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY 5201B RECEIPT Permit Number: EL11 -0030 Status: APPROVED Applied Date: 01/18/2011 Issue Date: Receipt No.: R11 -00258 Payment Amount: $264.50 Initials: JEM Payment Date: 02/10/2011 11:42 AM User ID: 1165 Balance: $0.00 Payee: VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 056485 264.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 264.50 Total: $264.50 doc: Receiot -06 Printed: 02 -10 -2011 CiP of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 01 -18 -2011 at 10:45:24 01/18/2011 RECEIPT NO: R11 -00095 Initials: JEM Payment Date: 01/18/2011 User ID: 1165 Total Payment: 145.16 Payee: KURT J PREISSLER, VECA SET ID: S000001463 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL11 -0030 EL11 -0031 TOTAL: Amount 66.13 79.03 79.03 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 145.16 TOTAL: 145.16 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 145.16 TOTAL: 145.16 INSPECTION RECORD Retain a copy with permit 644030 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ll: (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: 546 , 54216 /j Type of Inspection: itt7./40D Address: S • IGV ` , Date Called: Special Instructions: Date' Wanted: 7 /fr a.m Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. FOMMENTS: Inspector: /VGa ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 07 i9 i/ it • 1 INSPECTION RECORD �` Retain a copy with permit ^1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 6t4 -vo3o Project: a� Type of Inspection: X062 Address: )20 fie* Date Called: Special Instructions: Date Wanted: 21� a.m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. lo COMMENTS: 71, . G'�NJ� Calcr` atjA 4 &1I Inspector: tAbsti\ 1Date: o20 241 REINSPECTIOIV FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interpr Lighting Sur;. Lary 2001 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG -INT Revised November 2010 Project Info Project Address 3355 South 120th Place Date 1/17/2011 Tukwilla, Wa For Building Department Use FILE COPY Wm. 98168 Applicant Name: VELA Electric Applicant Address: 5614 7th Ave. S. Seattle, wa 98108 03,..,e„0.41* 1008 Applicant Phone: 206- 436 -5200 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition " Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Prescriptive QQ Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2 ** Gross Interior Area in ft2 Allowed x Area Level 2 Hallway 0.91 1008 917 Level 2 LED strip 1.5w per foot - 56' total 56 2 84 r Focal Point Avenue A - 4' -1t5 -28w 6 28 168 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 917 Proposed Lighting Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Level 2 Pinnacle Edge Ex44 -4'- 1- T5 -28w 4 28 112 Level 2 LED strip 1.5w per foot - 56' total 56 2 84 Level 2 Focal Point Avenue A - 4' -1t5 -28w 6 28 168 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 364 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of, crent limitin e . evices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note sect - - =.� •�•-�� 6�4Vatts/Fixture blank. APD MED FEB 07 2011 crtyilMILa JAN 18 2011 PERMIT CENTER City ofTukwila 0 D; BUILDING DIVISION 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential LTG INT Revised November 2010 Prescriptive Spaces Occupancy: 0 Warehouse or Parking Garage © Other Qualification Checklist Note: If occupancy type is `Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.85 .1 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA) Use' _ _ __ LPA` (Wife) Use' LPAz(W /fe) Automotive facility 0.85 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants /bars' 1.20 Police and fire stations _ 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers _ 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture _ 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries _ _ 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 =1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be turned off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. pr • avenue® FILE COPY • Permit No. • dimensional data Grid Mount Drywall Flange frame width REVIEWED FOR COD E COMPLIANCE APDW VFD FEB 07 2011 City of Tukwila BUILDING DIVISION Mounting yoke must be installed before drywall. (see Instruction Sheet )S0214 for details) lens o E M M \J_ 24 -30' Recommended Distance from Wall CIITOSIL.A JAN 182011 PERMIT CEN1€R FAVA -NS -1 T5HO -1 C -U NV -S -G 1- L835 -WH -4' FOCAL POINT' features Narrow aperture high performance T5 /T5H0 asymmetric wall wash. Precisiol v free illumination from the ceiling to the floor. Features 2" narrow aperture for clean unobtrusive aesthetic. Drywall installation is available, which allows for both individual or continuous row mount capability. Great solution for conference rooms, highlighting artwork, corridors, white board or any application that requires high levels of vertical illumination. detail shielding options drywall row mount open optic companion luminaire clear lens mrlb performance 1—Lamp T5H0 57% Efficiency 1933 cd @ 25° idea, everGreen linear recessed wall mount -00 hsr in place of multip'r hif uri o r Visit focalpointlights.com for 1,11,1,1 1,11,1,1 flonre. evil writ aashrrs complete photometric data. wa :,Juc,tlpu� tt y' I. t.un I 1.773.247 949° fixture: project: mounting information grid Standard Standard GI, TI, TOT G2, T2,T2T -Tall 0 vn,' 1ih — °ne Tall Node G4,T4,T4T G5, T5,T5T T6,T6T drywall I 1 2' unit (cutout dimension: 3.5' x 23.6 ") I 3' unit (cutout dimension: 3.5" x 35.6 ") 1� - Ae Slot tee G3 specifications lay -in tile tegular tle 4' unit (Cutout dimension: 3.5" x 47.6') 5' unit (cutout dimension: 3.5" x 59.6') Drywall flange version provided with mounting yoke. construction One -piece 20 Ga. steel housing. Grid luminaires include 20 Ga. steel, .5' wide universal flange rail. Drywall flange option is provided with 20 Ga. steel, .5" wide flange kit and 20 Ga. galvanized steel mounting yoke. 2' unit weight: 3' unit weight: 4' unit weight: 5' unit weight: 5 lbs. 6 lbs. 7 lbs. 8 lbs. optic .020' specular aluminum upper reflector and .020' semi - specular lower reflector. 24 Ga. perforated matte black diffuser with 24% opening. please note: radial cut -off louver FAVA -RL cannot be field installed on the non- shielded profile FAVA -N S. electrical Luminaires are individually wired for specified circuits. Thru - wiring not available. Electronic ballasts are thermally protected and have a Class "P" rating. Optional dimming ballasts available. Consult factory for dimming specifications and availability. UL and cUL listed. finish Polyester powder coat applied over a 5 -stage pre- treatment. Perforated diffuser always finished in Matte Black. • ordering luminaire series FAVA Avenue A FAVA s ' ding No Shielding, Open Opti • NS Snap -on Clear Lens CL (Radial cut -off louver FAVA -RL cannot be field installed on the FAVA -NS or FAVA -CL) tamping One LS� 1T5 One Lamp p T5H T5H 1T5H0 cult Single Circ 1C voltage 120 Volt 277 Volt 347 Volt 120 277 347 ballast Electronic Program Start <10% THD S Electronic Dimming Ballast* D ceiling configurations* Drywall nge F (Consult factory for custom variati Std: 15/16' Lay -in 1vt� Std. 15/16' Tegular Std. 15/16' Tegular, against Tee O Std. 9/16' Lay -in Std. 9/16' Tegular Std. 9/16' Tegular, against Tee 9/16' Slot -tee Tegular Tall 15/16' Lay -in ti 0 Tall 15/16' Tegular Tall 15/16' Tegular, against Tee Tall 9/16' Lay -In Tall 9/16' Tegular Tall 9/16'; Tegular, against Tee Node 9/16' Tegular Node 9/16' Tegular, against Tee G1 T1 T1T G2 T2 T2T G3 G4 T4 T4T G5 T5 T5T T6 T6T factory options Chicago Plenum CP Emergency Battery Pack* EM (3' & 4' Luminaires Only) Earthquake Clips EQ HLR /GLR Fuse FU Include 300 amp L830 Include 3500K Laniffill, L835 Include 4100K Lamp L841 Lutron1'" Sensor Feed* SF (EcoSystem ballast required) finish Matte White Housing WH Titanium Silver TS Matte Black Housing BK (Perforated diffuser always painted black) luminaire length 2' Nominal Housing 2' 3' Nominal H 3' 4' Nominal Housin 4' 5' Nominal Housing 5' (Dimming not available with 5' lamps) (For continuous row mount in drywall ceiling, specify luminaire run length, ie 24') 1C FAVA- NS- 1T5HO- 1C- UNV -S -G1- L835 -WH -4' avenue' a • • CANDLEPOWER DISTRIBUTION LUMEN SUMMARY Vertical Horizontal Angle Zonal Angle 0° 22.5° 45° 67.5° 90° Lumens Zone Lumens Lamp Fiat 0° 108 108 108 108 108 0° -30° 376 7.5 13.2 5° 276 256 214 154 101 13 0"40" 784 15:7 27.4 15° 919 771 499 291 102 85 0°60° 1975 39.5 69.0 25° 1933 1873 1300 415 101 279 Total 0 ° -90° 2861 57.2 100.0 35° 1832 1799 1695 707 96 408 Luminaire 0° -180° 2861 57.2 100.0 45° 1806 1775 1647 1296 88 610 55° 1434 1416 1329 1108 74 580 65° 1072 1052 962 811 56 473 75° 655 631 568 458 39 294 85° 317 294 224 129 14 119 90° 183 165 112 40 2 95° 0 0 0 0 0 0 105° 0 0 0 0 0 0 115° 0 0 0 0 0 0 125° 0 0 0 0 0 0 135° 0 0 0 0 0 0 145° 0 0 0 0 0 0 155° 0 0 0 0 165° 0 0 0 0 0 175° 0 0 0 0 0 180° 0 0 0 0 Go to www.focalpointlights.corn for additional photometric data. FAVA- NS- 1T5HO- 1C- UNV- S- G1- L835 -WH -4' • avenue a grid ceiling configurations Avenue A is configured at our factory to integrate easily with your specified grid type, tile style and fixture position. Please review the below options and choose the mounting code that matches your application. 1 1/2" G1 lay -in tile, any fixture placement tile style lay -in tile tegular tile _ _ n fixture position fixture between tees fixture against tee T1 tegular tile, fixture between tees 1 1/2 9/16 Standard 9/16' G2 lay -in tile, any fixture placement f l 9 /16n Slot Tee 9/16' G3 slot -tee tegular tile, any fixture placement www io:..1. puuuhgh:s , c -i 1 1 77s 247.9494 T2 tegular tile, fixture between tees T1T tegular tile, fixture against tee T2T tegular tile, fixture against tee FAVA -NS -1 T5HO -1 C- UNV- S- G1- L835 -WH -4' • FEATURES OPTICAL SYSTEM • Internal housing components painted matte black. Lamp snoot minimizes stray light in housing. • Semi - specular, matte - diffuse or specular cone with spread lens. • Seamless cast faceplate is retained by self - aligning, torsion support springs. • Optical system designed for spot lamps. • Tool -less 355° horizontal aiming adjustments are made wit optical system removed. • Adjustment mechanism is lockable to maintain focus during relamping. • Accommodates up to two lenses, filters or louvers. • Clear safety lens standard. MECHANICAL SYSTEM • Black painted housing features tool -less top access and accommodates a maximum 1 -1/2" ceiling thickness. • Re -lamp capability from above or below ceiling. • 16 -gauge galvanized steel mounting bars with continuous 4" vertical adjustment are shipped pre - installed. Post installa- tion adjustment possible without the use of tools above or below ceiling. • Secondary housing adjustment system for precise, final flange to ceiling alignment. • Galvanized steel junction box with hinged access covers_and spring latch. Four combination 1/2' -3/4" knockouts for raignEVIEWED F through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 A conductors, rated for 90 °C. ELECTRICAL SYSTEM APDQAVn° Type ¥LE COPY Catalog number Low Voltage Downlights 3" DLV Lensed Wallwash Seamless Cast Faceplate with Open Cone and Spread Lens Max 75 Watt ODE COMPLIANCE • Tool -less access door provides access to junction bo the aperture. • Replaceable socket assembly. MR16 socket assembly standard. • 12 -volt electronic transformer is replaceable without th of tools. • Thermally - activated insulation detector is replaceable without the use of tools. LISTING use FEB 0 7 ail CityotTu BUILDING DIVI4ION 15 -1/4 (38.7) • Fixtures are UL Listed for thru - branch wiring, Non -IC recessed mounting and damp locations. Listed and labeled to comply with Canadian Standards. All dimensions are inches (centimeters) 13 -11/16 (34.8) Aperture: 3 (7.6) Ceiling opening: 5- 1/16 (12.9) Overlap trim: 5.1/2 (14.0) ORDERING INFORMATION Choose the boldface catalog nomenclature that best suits your needs and write it on the appropriate line. Order accessories as separate catalog numbers (shipped separately). DLV WH 16 3AC 120 LD Series Configuration DLV WSH Aperture/Trim color Lamp designation MR16 MR16 capability (standard) MR11 MR11 capability ALR12 ALR12 capability ALR18 ALR18 capability AR70 AR70 capability 3BC' Black 3AC Clear 3PC Pewter 3UBC Umber 3WTC Wheat 3GC Gold Finish (blank) LD LS NOTES 1 Spot lamp recommended. 2 Not available with finishes. 3 For compatible Reloc systems, refer to Technical Bulletins tab. 4 Not available with ALMS and AR70 lamps. 5 Colors available for faceplate. Additional architectural colors available: please see brochure 794.3. Example: DLV WSH MR16 3AC 120 DWHG Voltage I Semi- 120 LRC' specular 277 Matte- 347 diffuse Specular DWHG Options Provides compatibility )S Architectural Colors (powder tinish with Uthonia Reloc DWHG Matte OMB System. Lithonia Reloc white System can be installed (standard) DNA less this option with connectors provided by others. Access above ceiling required SHHSG' HSG height reduced to 5.3/4' (14.61 Accessories • For lens accessories, refer to Technical Bulletins tab. C • For lamp options, refer to Technical Bulletins tab. DDB Dark bronze Black Gloss white DBL DWH JAN 18 2011 DSS DGC DTG DBR DSB Medium bronze Natural aluminum Sandstone Charcoal gray Tennis green Bright red Steel blue gotham® MWWIfl9arhWrperN _ GOTHAM ARCHITECTURAL DOWNLIGHTING 1400 Lester Road Conyers Georgia 30012 P 800 315 4982 F 770 860 3129 va gothamlighting.com PERMIT CENTER DLV H 3 ALV -16 wawa" • 3" DLV Lensed Wallwash TECHNICAL INFORMATION • For fixture -to -well distance other than those shown, use maximum of one -to -one spacing (distance between fixtures not more than distance to wall) for best l57V 22'h" results room wall 135" 45' 112V2 90" 67W Candlepower data Single luminaire tootcandle values DLV WSH MR16 3AC, Q50MR16 /C /NSP15 (EXT) lamp , 880 rated lumens, Test no. 2198012903 Vertical angle Plane angle Room side Wall side Room 15714° 135° 11234° 90° 6734° 45° 2214° Wall 0° 124 1 5° 85 8 15° 41 4 25° 2 2 35° 1 1 45° 55° 65° 75° 85° 90° 4 124 124 124 124 124 124 124 101 113 120 129 136 141 140 43 55 84 129 166 198 208 21 28 52 100 180 256 284 11 14 34 83 170 276 328 1 7 15 51 128 233 285 0 0 6 32 77 152 200 0 0 0 8 46 83 113 0 0 0 0 7 24 39 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Distance from ceiling Fixture 1' Fixture 2' Fixture 3' from wall from wall from wall Distance alon wall: 0' 1' 2' 3' 0' 1 2' 3' 0' 1' 2' 3' 4' 1' 101 22 2 0 22 11 2 0 5 4 1 0 0 2' 26 16 5 1 25 16 5 2 12 8 4 2 1 3' 7 7 4 2 14 11 6 3 11 9 5 2 1 4' 3 3 2 1 7 6 4 2 8 7 5 3 1 5' 1 2 2 1 3 3 3 2 5 4 3 2 1 6' 1 1 1 1 2 2 2 1 3 3 2 2 1 7' 0 1 1 1 1 1 1 1 2 2 2 1 1 8' 0 0 1 1 1 1 1 1 1 1 1 1 1 9' 0 0 0 0 0 1 1 1 1 1 1 1 1 10' 0 0 0 0 0 0 0 0 1 1 1 1 1 DLV WSH MR16 3AC , 65MR160/10 /NSP (FPA) lamp, 1100 rated lumens, Test no. 2198011404 Vertical Plane angle angle Room side Wall side Fixture 1' Fixture 2" Fixture 3' Room 15715° 135° 11235° 90° 6715° 45° 2214° Wall 0° 186 1 6 186 186 186 186 186 186 186 5° 106 1 6 130 150 182 191 187 190 188 15° 3 3 42 64 104 178 232 272 282 25° 1 1 21 2 62 129 244 367 414 35° 9 1 41 100 228 413 524 45° 1 20 68 183 372 505 55° 0 9 33 123 255 357 65° 0 1 14 67 146 197 75° 0 0 0 4 26 49 85° 0 0 0 0 0 0 90° 0 0 0 0 0 0 Distance from ceding from wall from wall from wall Distance alon' wall: 0' 1' 2' 3' 0' 1' 2' 3' 0' 1' 2' 3' 4' 1' 179 34 2 0 40 18 3 0 10 6 1 0 0 2' 39 22 6 2 45 26 9 3 22 14 7 3 1 3' 10 9 5 2 22 16 8 3 20 15 8 4 2 4' 4 5 3 2 10 9 5 3 13 10 7 4 2 5' 2 2 2 1 5 5 4 2 7 7 5 3 2 6' 1 1 1 1 3 3 2 2 4 4 3 2 2 7' 1 1 1 1 2 2 2 1 3 3 2 2 1 8' 0 1 1 1 1 1 1 1 2 2 2 1 1 9' 0 0 1 0 1 1 1 1 1 1 1 1 1 10' 0 0 0 0 0 1 1 1 1 1 1 1 1 NOTES 1 Tested to current IES and NEMA standards under stabilized laboratory conditions. Various operating factors can cause differences between laboratory data and actual field measurements. Dimensions and specifications are based on the most current available data and are subject to change without notice. ALV -160 C2007. 2009 Acuity Brands Lighting, Inc. All Rights Reserved. got h a m anossailyannsaConawe GOTHAM ARCHITECTURAL DOWNUGHTINO A DIVISION OF ACUITY LIGHTING GROUP, INC, 1400 Laster Road Conyers Georgia 30012 P 800 315 4982 F 770 860 3129 www.got ham hghti ng.com I 11 ARCHITECTURAL LIGHTING" F I N N A C L E • EDGEEx44 DIRECT 4 X 4 with ACRYLIC LENS CONSTRUCTION 6063 -T5 extruded aluminum hous- ing. Highly reflective die - formed white painted alu- minum reflector, .125' diffuse snap -in acrylic lens with matte finish, removable for lamp replacement. ELECTRICAL Standard T5 and T5HO: Program start 120/277 volt integral electronic ballast with less than 4' 10% THD. Standard T8: Instant start 1201277 volt electronic ballast with less than 10% THD. Through wiring with quick connects standard. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement. MOUNTING Aircraft cable, 1/2' diameter rigid stem pendant, wall and surface mount available. Adjust- able aircraft cable mounts on 4' -0" 8' -0' and 12' -0" centers (See back page for MR16 mounting detail). Aircraft Cable supplied with 5" power and 2" non - power canopies. Refer to installation instructions for appropriate ceiling detail and rigid pendant details. Pendants, canopies, and power cords are painted white unless otherwise specified. FINISH Standard powder -coat textured white painted finish. Consult factory for custom colors. LABELS UL and cUL Listed, approved for dry /damp location unless otherwise noted. -- 4 -7/16' 1 EX44 -A EX44 -WA LUMINAIRE SPECIFICATION EX44- - N LAMPS Individual Units 4- 4' 8- 8' 12- 12' Continuous Runs xx'- Specify nominal overall row length in 4' increments A- Acrylic Lens WA- Asymmetric with Acrylic Lens 175- (1) 28W T5 1T5H0- (1)54W T5H0 1T8- 1 32W T8 2T5H 1- (2) 54W T5 2T8- (2) 32W T81 Sample Catalog #: EX44-A- N- 1T5- 24- AC48G1- 120 -1C -W 120- 120 V 277. 277 V 347. 347 V5 UNV- UNV5 (120/277) Aircraft Cable2 AC48G1- 1" 7-Bar' AC48G9- 9/16' T -Bar3 AC48GS- Slotted T-Bar3 AC48JB- Junction Box AC48ST- Structure AC5_G_ 5" Non -Power Canopy' AC5_JB- 5' Non -Power Canopy' Pendant2 PP_JB- Junction Box (seedy C.AL,12",18` or 24') PP $T• structure Wall (specify C.AL.,12",18' or 24') WA- Wall Mount Surface (Ceiling) S- Ceiling Surface Mount 1C- Single Circuit 2C- Dual Circuit' 10- Single Circuit Dimming' 2D- Dual Circuit Dimming' 1E- Single Circuit with Emergency Circuit' 2E- Dual Circuit with Emergency Circuit' 1B- Single Circuit with Battery Pack" 2B- Dual Circuit with Battery Pack' MR16- MR16' Not available with Asymmetric Lamp with Acrylic Lens option (WA). 'Consult factory or additional lengths. 'Consult factory for tegular edged files. 'Replaces standard 2' non-power canopy. 'Not available with MR16 and battery pack. 'Some Edge EX configurations wit not accommodate all electrical options. Consult factory. 'See Back Page for layout and Ordering Information. COMPONENTS Individual Luminaires 48.0.1 4' 8' 12' I - (1) lens per 4' unit 96.0'1 (1) lens per 8' unit 144.0 "1 I (1) 8' lens and () 4' lens per 12' housing 4' 8' 12' T5 1 or 2 -28W dr4 ,,, 3 or 6-28W T5H0 1 or 2 -54W 2 or 4 -54W 3 or 6-54W TS 1 or 2 -32W 2 or 4 -32W 3 or 6-32W 1Add 1/16" for each end plate or 1/8" to the overall length of the row. Mounting Options .1l AC- Aircraft Cable PP- Rigid Stem Pendant Wall Mount Options (WA) 1/2" I J 1/2' (EX44 -A-N) (EX44 -WA-N) S - Surface Mount PINNACLE ARCHITECTURAL LIGHTING" 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 wwwpinnade- Itg.com Specifications and dimensions subject to change without notice. Specification sheets that appear on December 2009 pomade -Itg corn are the most recent version and supersede all other previous printed or electronic versions. C 2009 Pinnacle Architectural Lighting' Project: SABEY Description: EX44 -A -1 T5 -08' -S -277 -1 C -W Type: 40I • PHOTOMETRICS • EDGE EX44 DIRECT Test# 203 62 Test# 203165 Part # EX44- A -N -1T5 Part # EX44- A -N -2T5 Total Efficency: 79.8% Total Efficency: 75% FEATURES AND OPTIONS Test # 203 64 Part # EX44- A -N -1T8 Total Efficency: 65.2% Test # 203 67 Part # EX44- A -N-2T8 Total Efficecny: 56.7% • MR16 HALOGEN LAMP EDGE EX Layout Options 1' Colon M4 6'1 48' 104 16.1 Option 3 =M4M 46 1▪ 6'1 104 +01 • Mates fodure mounding bratims t 4M' 15'1 Option 2 =4M f +01 Consult factory for MR16 applications as detailed shop drawings 10z are required. 15'1 45' 45' Optinn4 =4Ma APPLICATION: EDGE EX44 offers both task and accent lighting when used with MR16 lamps. MR16's are Ideal for conference Opim5' rooms, corridors, wall washing, retail spaces and training facilities. TECHNICAL: MR16 6' fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20,35 and 50 watt halogen lamps Opp 6' 4M4M (lamps not Included). Consult factory for other lamp types. Lamp tilts to 35 degrees with 358 degree rotation. ELECTRICAL: Standard 50 watt max halogen lamp transformer. MR16 Option7'M4M4M Installed as independent circuit MR16 voltage to match fluorescent voltage. Universal voltage and 347 volt not available with MR16. LENS: MR16 available in 5 different lens options: Clear Lens (LC), Prismatic Optbn 8' M12M Lens (LP), Linear Spread Lens (LL), Diffuse Spread Lens (LD) and Frosted Lens (LF). Clear lens provided with each MR16. LABELS: UL and cUL Listed, approved for dry /damp location unless Option 9.481014 otherwise noted. ORDERING INFORMATION: Specify MR16 layout and lens In the options section of the part number. See right for Edge EX layout options. Sample Oflticli 10' M4M4M4M Catalog #: EX44- A- N- 1T5- 24- AC48G1- 120.1C- W- 44MJLP. f5') 45' 1m' 16'1 45' 101 101 48' 108' 16') 45' 16. 101 tQI 114' 16' 4 . 16' l le' 15' lot tot t01 155' 144' 5'1 16. 104 48" 155' 48' 16'1 48' 101 101 6'1 (04 48' 101 168' 45' 16'1 48' _ 101 If 401 • CIRCUITING (shown using 2 lamp cross sections) Single Circuit (1C) Layout j 8CC-IC 8CC-1C Dual Circuit (2C) Layout j 8CC-2C 8CC-2C celanssimao I Circuit 1® P =Power Circuit low Circuit 2 wn P =Power Dual Circuit with Emergency Circuit (2E) Layout Circuit 1 oce 8CC-2E 8EC -2E' j Circuit 2 - '� I EC Circuit ow ®111lO7" ® P =Power 'Emergency Circuit is not dual circuited • STANDARD ROW CONFIGURATION Individual Length Row Length 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 4' 1 8' 1 2 1 2 1 2 1 2 1 2 1 2 1111131111111111111111111111111=1111111^111111111111111111111111111131111112111111111111 6 E 6 PINNACLE ARCHITECTURAL LIGHTING' 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnacle.Itg.can Specfica5ons and dimensions sub ect to change without rnotice. Specification sheets that appear on December 2009 pinnadeatg.00m we the most recent version and supersede at other previous printed or electronic versions ® 2009 Pinnacle Ardilecbnal Lighting" Project: SAB EY Description: EX44 -A -1 T5 -08' -S -277 -1 C -W Type: l • P I N N A C L E "ARCHITECTURAL LIGHTING' • EDGEEx44 DIRECT 4 X 4 with ACRYLIC LENS CONSTRUCTION 6063 -T5 extruded aluminum hous- ing. Highly reflective die - formed white painted alu- minum reflector, .125' diffuse snap -in acrylic lens with matte finish, removable for lamp replacement. ELECTRICAL Standard T5 and T5HO: Program start 120/277 volt integral electronic ballast with less than 10% THD. Standard 78: Instant start 120/277 volt electronic ballast with less than 10% THD. Through wiring with quick connects standard. Standard single circuit. Each ballast provided with disconnects to meet luminaire disconnect code requirement. MOUNTING Aircraft cable, 1/2" diameter rigid stem pendant, wall and surface mount available. Adjust- able aircraft cable mounts on 4' -0" 8' -0" and 12' -0" centers (See back page for MR16 mounting detail). Aircraft Cable supplied with 5" power and 2" non - power canopies. Refer to installation instructions for appropriate ceiling detail and rigid pendant details. Pendants, canopies, and power cords are painted white unless otherwise specified. FINISH Standard powder -coat textured white painted finish. Consult factory for custom colors. LABELS UL and cUL Listed, approved for dry /damp location unless otherwise noted. .— 4-7/16'7 4' EX44 -A LUMINAIRE SPECIFICATION EX44- must Nn EX44- Edge EX 4X4 DIRECT N INDIRECT N- None, Closed dividual Units 4- 4' 8- 8' 12- 12' Continuous Runs xx'- Specify nominal overall row length in 4' increments T5 -w 1y 4 ,28W 75 1T '0- (1)54WT5H0 1T8- (1)32W T8 2T5- (2) 28W T5' 2T5H0- (2) 54W T5H0' 2T8- (2) 32W T8' Sample Catalog /t: EX44- A- N- 1T5- 24- AC48G1- 120 -1C -W VOLTAGE 120- 120 V 277- 277 V 347- 347 V5 UNV- UNVS (120/277) Aircraft Cable AC48G1- 1"T -Bar3 AC48G9• 9/16' T -Bari AC48GS- Slotted T -Bari AC48JB- Junction Box AC48ST- Structure ACS_G_ 5" Non -Power Canopy4 AC5 —JB- 5" Non -Power Canopy' Pendant2 PP —J& Junction Box (specify O.AL, 12", 18'or24') PP_ST- Structure Wall (specify CAL, 12", 18' or 20) \1st WA. Wall Mount urface (Ceiling) S- Ceiling Surface Mount OPTIONS W- Matte White CC- Custom Color 1C- Single Circuit 2C- Dual Circuit. 1D- Single Circuit Dimming' 2D- Dual Circuit Dimming" 1 E- Single Circuit with Emergency Circuit. 2E- Dual Circuit with Emergency Circuit. 1B- Single Circuit with Battery Pack' 2B- Dual Circuit with Battery Pack• MR16- MR16' 'Not available with Asymmetric Lamp with Acrylic Lens option (WA). 'Consult factory for addllorel lengths. 'Consrdt factory for tegular edged tiles. 'Replaces standard 2' non-power canopy. 'Not available with MR16 and battery pack. "Some Edge EX configurations will not accommodate all electrical options. Corset factory. 'See Back Page for Layout and Ordering Information. COMPONENTS Individual Luminaires 48.0'1 4 8 12 .sy (1) lens per 4' unit 96.0'1 (1) lens per 8' unit 144.0 't nft (1) 8' lens and ( ) 4' lens per 17 housing TS T5H0 4' NIkir,2428Wi 1 or 2 -54W 8' 2 or 4-28W 2 or 4-54W 12' 3 or 6-28W 3 or 6 -54W T8 1 or 2 -32W 2 or 4 -32W 3 or 6-32W 1Add 1/16" for each end plate or 1/8" to the overall length of the row. Mounting Options AC - Aircraft Cable PP - Rigid Stem Pendant Wall Mount Options (WA) 1/2" (EX44 -A -N) (EX44-WA -N) S - Surface Mount PINNACLE ARCHITECTURAL LIGHTING" 12655 East42ndAvenue, Suite 50 Denver, Colorado80239 Ph 303.322.5570 Fax 303.322.5568 www.pinnade- Itg.com Specifications and dimensions subject to change without notice. Specification sheets that appear on December 2009 pinnacle -ltg corn are the most recent version and supersede all other previous printed or electronic versions. ® 2009 Pinnacle Architectural Lighting' Project SAB EY Description: EX44 -A -1 T5 -04' -S -277 -1 B(ISL28W) -W Type: • PHOTOMETRICS • EDGE EX44 DIRECT Test # 203 62 Test # 203165 Part # EX44- A -N -1T5 Part # EX44- A -N -2T5 Total Efficency: 79.8% Total Efficency: 75% FEATURES AND OPTIONS Test # 203 64 Part # EX44- A -N -1T8 Total Efficency: 65.2% Test # 203 67 Part # EX44- A -N-2T8 Total Efficexry. 56.7% • Indptes • MR16 HALOGEN LAMP APPLICATION: EDGE EX44 offers both task and accent lighting when used with MR16 lamps. MR16's are Ideal for conference rooms, corridors, wall washing, retail spaces and training facilities. TECHNICAL: MR16 6' fully enclosed compartment eliminates light from entering into other fixture areas. Available in 20, 35 and 50 watt halogen lamps (lamps not Included). Consult factory for other lamp types. Lamp tilts to 35 degrees with 358 degree rotation. ELECTRICAL: Standard 50 watt max halogen lamp transformer. MR16 installed as Independent circuit MR16 voltage to match fluorescent voltage. Universal voltage and 347 volt not available with MR16. LENS: MR16 available in 5 different lens options: Clear Lens (LC), Prismatic Lens (LP), Linear Spread Lens (LL), Diffuse Spread Lens (LD) and Frosted Lens (LF). Clear lens provided with each MR16. LABELS: UL and cUL Listed, approved for dry/damp location unless otherwise noted. ORDERING INFORMATION: Spedfy MR16 layout and lens In the options section of the part number. See right for Edge EX layout options. Sample Catalog #: EX44- A- t41T5- 24- AC48G1- 120- 1C- W- M4MILP. EDGE EX Layout Options Option 1=184 fable mounting bca0ms 161 48' f 1 48' 161 Option 2' 4M 10+ 161 Option 3 -M4M 16t 104 401 102' 46 161 4r Op5on4 =4M4 401 Consult factory for MR16 applications as detailed shop drawings 1 are required. Option 5414M4 Opfprt 6' 4M4M Option 7' M4M4M Option 8' M12M Option 9.4814844 Option 10' M4M4M4M 161 1ti6 46 161 48' lot 101 1 46 106 161 48' 16 101 pal 161 46 114' 161 46 16 lot 101 tol 61 158' 144' 16 lot 401 46 161 156 48' 161 46 lot tot -161 46 161 lot tot 161 // 46 161 101 I7 401 • CIRCUITING (shown using 2 lamp cross sections) Single Circuit (1C) Layout j 8CC-1C 8CC-1C r Dual Circuit (2C) Layout j BCC -2C 8CC -2C Circuit 1 as P =Power Circuit 1 um Circuit 2we P =Power Dual Circuit with Emergency Circuit (2E) Layout Circuit 1 CZI 8CC-2E 8EC -2E' Circuit 2 ern f ' 1 EC Circuit 1223 *Emergency Circuit is not dual drculted • STANDARD ROW CONFIGURATION Individual Length Row Length 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 68 72 76 80 4' 1 8' 1 2 1 2 1 2 1 2 1 2 1 2 1 12' 1 1 2 1 2 3 2 3 4 3 4 5 4 5 6 5 6 PINNACLE ARCHITECTURAL LIGHTING'''. 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239 Ph303.322.5570 Fax 303.322.5568 www.pinnacle- Itg.com Specifications and dimensions subject to change wi tout notice. Specification sheets that appear on December 2009 pinnade-ttg.00m we the most recent version and supersede all other previous printed or electronic versions C 2009 Pinnacle Amldtecdaal Lighting^' Project SABEY Description: EX44 -A -1 T5 -04' -S -277 -1 B(ISL28W) -W • • LEDR SERIES -LED RIBBON STANDARD LED RIBBON • 8mm(.31 ") wide and 0,2mm(.01 ") thick ribbon contains 60 LEDs per meter(1 8 LEDs perff) • Highly flexible circuit board with 3M adhesive tape can be applied to most accessible surfaces • Can cut every 50mm(2 ") and connect with quick connectors • Energy consumption: 1 .5 watts per foot compared to incandescent linear light that draws 20 -40 watts per foot • 4114 f • Powered by DC 12V power.suppiy, low, voltage, low heat, more safety • Durable LEDs with :an .average life£of 50 00 a hours. • No UV, no mercury and.1RoH Dimensions 1000mm 39.37" 50mm 16.54mm 0.65" 1.97" EIS N (V • LEDR - ROLLRED ®RED., au LEDR - ROLLYELLOW YELLOW LEDR - ROLLBLUE 0 BLUE LEDR - ROLLGREEN ® GREEN LEDR- ROLLWW ❑ WARM WHITE LEDR - ROLLNW ❑ NATURE WH LEDR - ROLLWH ❑ WHITE LEDR - ROLLCW ❑ COOL WHITE 160 =170 20;180 50 -160 • ;.320-340 200 -260 .4:08180"': ° A ' 320 -340 340 400 d 80 s • 340 -360 -340,900; • 4.084.80 340 -360 'r •r 5 meter /reel 16.4ft/reel 06 -30 -2011 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director KURT PREISSLER 5614 7 AV S SEATTLE WA 98108 RE: Permit No. EL11 -0030 3355 S 120 PL TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/24/2011. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, , provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/24/2011, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, .11° Bill Rambo Permit Technician File: Permit File No. EL11 -0030 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: ELI 1-0030 DATE: 01/18/11 PROJECT NAME: SABEY SITE ADDRESS: 3355 S 120 PL, STE 5201B X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: �Y1 �I ing Di eft Public Works Fire Prevention Structural u Planning Division Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete p. Comments: Incomplete DUE DATE: 01/20/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/17/11 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Document shouting sl ip.doc 2 -28 -02 Contractors or Tradespeople Piper Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7Th Ave S PO BOX 80467 Seattle WA 98108 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601190731 Active VECAECI542MU Electrical Contractor 7/31/1946 10/31/2011 General Unused Master Electrician INFORMATION License CONTIK'965D6 Name CONTI, KEITH Status Active Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON Agent 01/01/1980 929407110 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Until Cancelled 19.28.101 RCW ELECTRICAL CITATION $4,000.00 01/06/2007 6 TRAVELERS CAS SURETY CO 0815103520497 01/06/2001 Until Cancelled 01/06/2007 E54947 $4,000.00 01/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount EBOES00247 5/30/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $2,000.00 EBOES00447 3/9/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 EJONV00207 9/13/2005 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 E54947 8/8/2005 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000556 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000548 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000561 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000547 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 EMEH000559 4/19/2006 19.28.161(6) RCW ELECTRICAL CITATION Satisfied $250.00 https:// fortress .wa.gov /lni/bbip/Print.aspx 02/10/2011 ES: 1. ELECTRICAL/LIGHTING UNDER SEPARATE PERMIT. 2. MECHANICAL UNDER SEPARATE PERMIT. 3. SPRINKLERS UNDER SEPARATE PERMIT. LEG ND: 1. A — 45(10' Panel-NIC 2. B 42"x60" Aqua Panel 3., C 36"x36" Blue Panel DW-l4-4t% Wallcovering by Sabey • ; ; , 3ELICL o.. SZSOSS M.SSM MAN SZSZ. MS= isSAVS {62,(6.1 Mal MSS.. WM* SOMMA SWAM MMUS* ZSMSS saws MOMM MSSSAS iSSSMAI NOSSItt MISMS MMUS MAWS MO= WORM WSW MM. Fixture with Emergency Lighting Area of Work SDC 5201B *V"' '36" "52V *WM 'MZZ' WM° t***2 "" EQ. Ms'..SMY / / / !WW1. MD.W.WOM Offi,55555. MS.. .5.902 .140 9.4619 4555555. (555555.1 i6666666, 547/9191 555555 9$619999. 54459 .454b5555525, 545.99 4r69'. *951.296 " .42559S55 CANDDS59 I *msssm mwom Isms. mmmo momm ...me Immo omm. momm mosso mmm. .ssm. OVERALL C L NCR A\ NEV ACT Celting Dropped ACT See 3,11D2.0 3 20 MOM sccle: 1/8" = 1' )) SEPARATE PERMIT REQUIRED FOR: [(Mechanical 0 Electrical DI Plumbing 2rIGPas Piping City of Tukwila UILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Meto.E Mesh ring New LED inside ring by Dynamik CF NG PLAN -w*-REVIEWED FOR CODE COMPLIANCE APIA:MED FEB 0 7 2011 bL UAL City of Tukwila BUILDING DIVISION scale: 1/8" = 1' )) CITY JAN • 8 2011 PERMIT MIER D 'YNAMIK 615 Second Avenue Studio 720 seattle, wa 98104 206.686.2525 ph/fax melaniedynamikspace.com FILE COPY Permft No. 01)30 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize th violation of any adopted code or ordinance. Receipt oi approved Field Copy and oonthtionsis acknowledged: By "1"4e7rtAT a. TA& Date: city of /devils BUILDING DIVISION (/) oJ 0 CL ) L. C 0 o re) rr) OVERALL RCP APPROVED: DATE: APPROVED: DATE: DRAWN BY CHECKED BY: CLIENT APPROVAL... DRAWING Melanie Corey-Ferrini Pricing SET DATE:: NO. DA S S U 0 January 7, 2011 • REVISIONS DESCRIPTION: BY 1,7.1 1 REVISION REVISION MG MG PROJECT NUMBER: 10-2096 PROJECT MGR: Melanie Corey--Ferrini TI\G SCHEDUL= LC- Refer to Reflected Ceiling Plan, Architectural Plans, and Elevations for Locations GENERAL LIGHTING SYMBOL FIXTURE LOCATION NOTES QTY. 1 massmisma Focal Point Avenue A 4.5"x4'-0" LINEAR FLUORESCENT LIGHT Mount to ACT Secondary Axis SDC— 5201B by VECA 6 2 P Pinnacle Edge EX44 E=EEEEE LINEAR FLUORESCENT LIGHT 4"x 4'—O" Mount to Unistrut 28W T5 by VECA 4 , ES: 1. ELECTRICAL/LIGHTING UNDER SEPARATE PERMIT. 2. MECHANICAL UNDER SEPARATE PERMIT. 3. SPRINKLERS UNDER SEPARATE PERMIT. LEG ND: 1. A — 45(10' Panel-NIC 2. B 42"x60" Aqua Panel 3., C 36"x36" Blue Panel DW-l4-4t% Wallcovering by Sabey • ; ; , 3ELICL o.. SZSOSS M.SSM MAN SZSZ. MS= isSAVS {62,(6.1 Mal MSS.. WM* SOMMA SWAM MMUS* ZSMSS saws MOMM MSSSAS iSSSMAI NOSSItt MISMS MMUS MAWS MO= WORM WSW MM. Fixture with Emergency Lighting Area of Work SDC 5201B *V"' '36" "52V *WM 'MZZ' WM° t***2 "" EQ. Ms'..SMY / / / !WW1. MD.W.WOM Offi,55555. MS.. .5.902 .140 9.4619 4555555. (555555.1 i6666666, 547/9191 555555 9$619999. 54459 .454b5555525, 545.99 4r69'. *951.296 " .42559S55 CANDDS59 I *msssm mwom Isms. mmmo momm ...me Immo omm. momm mosso mmm. .ssm. OVERALL C L NCR A\ NEV ACT Celting Dropped ACT See 3,11D2.0 3 20 MOM sccle: 1/8" = 1' )) SEPARATE PERMIT REQUIRED FOR: [(Mechanical 0 Electrical DI Plumbing 2rIGPas Piping City of Tukwila UILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Meto.E Mesh ring New LED inside ring by Dynamik CF NG PLAN -w*-REVIEWED FOR CODE COMPLIANCE APIA:MED FEB 0 7 2011 bL UAL City of Tukwila BUILDING DIVISION scale: 1/8" = 1' )) CITY JAN • 8 2011 PERMIT MIER D 'YNAMIK 615 Second Avenue Studio 720 seattle, wa 98104 206.686.2525 ph/fax melaniedynamikspace.com FILE COPY Permft No. 01)30 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize th violation of any adopted code or ordinance. Receipt oi approved Field Copy and oonthtionsis acknowledged: By "1"4e7rtAT a. TA& Date: city of /devils BUILDING DIVISION (/) oJ 0 CL ) L. C 0 o re) rr) OVERALL RCP APPROVED: DATE: APPROVED: DATE: DRAWN BY CHECKED BY: CLIENT APPROVAL... DRAWING Melanie Corey-Ferrini Pricing SET DATE:: NO. DA S S U 0 January 7, 2011 • REVISIONS DESCRIPTION: BY 1,7.1 1 REVISION REVISION MG MG PROJECT NUMBER: 10-2096 PROJECT MGR: Melanie Corey--Ferrini Existing HVAC CD 0) CORRIDOR �So,t-\ evctio scale: 1/4" = 1' 8" 99 i TYRE I MT'L. HM Ge -C3 "I ,_1m Door Scheo ASSEMBLY RATING...... 45 New Door I- evc 3 scale: 1/4" = 1' tion u le i-� �WR FRAME TYPE 4 B FRAME HEAD MT'L DETAIL NM 7 /IDE.O KW-4 Access douoie door 3 PR Butts 1 Lever. Handle Mortise L.ockset (active leaf) 1 I....oc:k (active Leaf) 1 Set Self 1„..atching Flush Bolts (Top & bottom inactive leaf) 2 Closers 1 Set Smoke Gaskets at Rated Doors 1 Coordinator 1 Set SRencers JAMB DETAIL /1132,0 99 Metc Ves DoT TO scAL- MESH PANEL CLOUD WEIGHT=125# NOTE: LIGHT FIXTURES TO BE INSTALLED PER IBC CHAPTER 27 C OL d Axo HVAC above Varies- See Devotions Varies_ fee Flan CL. Mctc scale: des 299 1' C 0 d ARMSTRONG MAIN BEAM NOIES: 1. ELECTRICALILIGHTING UNDER SEPARATE PERMIT. 2. MECHANICAL UNDER SEPARATE PERMIT. 3. SPRINKLERS UNDER SEPARATE PERMIT. L/2.) S,S Existin g/ HVAC /„„ ........... New Lighting New ACT Ceiling Sccondcry Axis Section scale: 1/4" = 1 -0° min: 3/8" ARMSTRONG MAIN BEAM ACT Cr°d—Wc on nection ARMSTRONG STABLIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS FROM SPREADING A=PART, ARMSTRONG MAIN BEAM ARMSTRONG CONTINUOUS min, 3/8" SHADOW MOLDING - €.ttach to existing Mn, i 7/8" metal stud wall, scale: not to scale 1301± to unistrut and metal mesh frame, Unlstrut< Attach to '" Continuous wall angle< Attach to metal stud wall ( 2e-0" Lc, (wait to wall) LED light 2" Frame. /Th on Rod for StabIllty Adjust on site �cctio � @ We 99 1 o ow Metc Door lecd ELI . STUD WALL. ,)EE PLAN FOR SIZE (DOUBLE STUD AT JAMBS). HOLLOW METAL FRAME WRAP AROUND GYP. BD, HOLLOW METAL DOOR Frc (Jcm me b, S* Q030 REVIEWED Fpp CODE COMPLIANCE ADDD'?f VED FEB 0 7 2011 scale: 3 "= 1' 99 City of Tukwila BUILDING DIVISION crtvFMRIn JAN' 18 2011 PEwMITCEN1ER DYNAMIK 615 Second Avenue Studio 720 seattle, wa 98104 206.686.2525 ph /fax melanie @dynamikspace.corn EL -TAILS APPROVED: DATE: APPROVED: DATE: DRAWN BY: iJ I....I 6... E ' T APPROVAL.. DRAWING CHECKED BY: MelarnieC'crey_Ferrini PERMIT SET DATE: February 27; 2008 NO DATE: DE SCRIPT l_J L REVISIONS ON : BY PROJECT NUMBER: 10-2077 PROJECT MGR: Melanie C.orey_Ferrin€ D2.O CORRIDOR Existing HVAC N) SoLt -evctio scale: 1/4" = NIC 73 N West evc too CORRIDOR Ne W Fire Cab scale: 1/4" = 1 —C° ARMSTRONG MAIN BEAM ARMSTRONG AIN BEAM ACT Cric U —Wc 0 c Ll0 min. �i --min: 31 8 " rmin> 7/8' ARMSTRONG STABLIZER BAR, OR OTHER SUITABLE SYSTEM, TO KEEP PERIMETER COMPONENTS E' TS FROM SPREADING APART, ARMSTRONG MAIN BEAM ARMSTRONG CONTINUOUS SHADOW MOLDING -attach to existing metal stud wall, scale: not to scale meememesEs --New New L €ght€ng New ACT Ceiling Sccondcry AXTS—SCCTIO scale: 1/4" = 1 - -0" Meta Vcs \OT TO SCAL- ,Th CLOUD WE GHT =125 NOTE: LIGHT FIXTURES TO BE INSTALLED PER IBC CHAPTER 27 J d Axo HVAC above Varies- -See Devotions Varies-See Flan Vctcl C✓L.. NOIES: t ELECTRICAL /LIGHTING UNDER SEPARATE PERMIT. 2. MECHANICAL UNDER SEPARATE PERMIT. a SPRINKLERS UNDER SEPARATE PERMIT. ELW» 003 vas 0 REVIEWED FOR CODE COMPLIANCE ApogAVep FEB 0 7 2011 City Tukwila c' ofr BUILDING DIVISION Ci ofT ' BUILDING DIVISION Bolt -to unistrut and metal mesh frame, -2x2 Unistrut Attach to 2" Continuous watt angle, Attach to metal stud watt 2' -O" ❑,C, (watt to watt) light —2" Frame d Con ciTAWARiA JAN' 18 2011 PERMIT t t ction @ We scale: 2" = 1' )) DYNAMIK 615 Second Avenue Studio 720 seattle, wa 98104 206.686.2525 ph /fax melanie @dynamikspace.com ELEV /D =TAILS APPROVED: DATE: A APPROVED: DATE:: CLIE.N..T. APPROVAL.. 'RA WI DRAWN BY: CHECKED Ear: Melanie, Corey -F {.rein€ PER v I T SET DATE: S S _ ° D February 27, 2008 NO. DATE: E..E. SCRI P f REVISIONS ON: BY P OJEC., ( NUMBER: 10-2077 PROJECT MGR: Melanie Corey- errini D2.0