Loading...
HomeMy WebLinkAboutPermit EL11-0077 - SIGHTLINE HEALTHSIGHTLINE HEALTH 200 ANDOVER PK E EL1 1 -0077 Parcel No.: Address: Tenant Name: City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://wwwcitulcwila.wa.us 0223100099 200 ANDOVER PK E TIIKW SIGHTLINE HEALTH ELECTRICAL PERMIT Permit Number: EL11 -0077 Issue Date: 03/22/2011 Permit Expires On: 09/18/2011 Owner: Name: Address: Contact Person: Name: Address: ANDOVER PLAZA LLC 1501 N 200TH ST , SHORELINE WA 98133 TED BRANDVOLD 616 14 ST , MODESTO CA 95354 Contractor: Name: NORTH STAR ELECTRIC INC Address: 1905 S JACKSON ST , SEATTLE WA 98144 Contractor License No: NORTHSE 13608 Phone: 209 - 571 -8158 Phone: 206 - 329 -1596 Expiration Date: 09/28/2011 DESCRIPTION OF WORK: ELECTRICAL TENANT IMPROVEMENTS WITHIN EXISTING SPACE FOR CANCER TREATMENT MEDICAL OFFICE /FACILITY Value of Electrical Work: NRES: $100,000.00 Fees Collected: $1,979.25 RES: $0.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Al4 I r I hereby certify that I have read and examined this permit .p d know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit and agree to the conditions on the back of this permit. National Electrical Code Edition: 2008 c7g72— Date: Signature: Print Name: /e) .51.7 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -9/09 EL1 1-0077 Printed: 03 -22 -2011 PERMIT CONDITIONS Permit No. EL11 -0077 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -9/09 EL11 -0077 Printed: 03 -22 -2011 CITY OF TUK A Community Development Department Permit Center 6300- Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.ci. tukwila. wa. us Electrical Permit No. "ELI 1 0i5'7 l Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: r7 221-2 Site Address: 2 fX7 kr.4- 7'Suite Number: Floor: Tenant Name: ,4' New Tenant: ❑ Yes ❑ .. No Property Owners Name: Mailing Address: ✓O 1 G City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name /� _,�ts� ✓� /G� �-• Mailing Address: Day Telephone: �- • S^% //. City State Zip Fax Number: '2-% • E -Mail Address- ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ /%e='p • O47 Scope of Work (please provide detailed information) ��it�� /�Y- �►��j��1 �f��j Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes • . No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:Wpplications\Porns- Applications On Line\2010 Applications \7 -2010 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) $152.85 $81.90 ea $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter /mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $63.00 ❑ Temporary service (generator) $78.75 ❑ Manufactured/mobile home service $84.00 (excluding garage or outbuilding) ❑ Carnivals $78.75 Number of concessions $10.50 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ELECTRICAL CON CTOR: Signature: �:, Date: Print Name: heesA,A.",c,ejt.=> /,,A,...677-%-',A-A,47:4, Day Telephone: O.4 S aj Mailing Address: / CJ City State Zip Date Application Accepted: Date Application Expires: t Staff Initials: - r H: Wpplications\Fomu- Application, On Iine12010 Applications17 -2010 - Electrical Permit Application.doc bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: 11 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov 0223100099 200 ANDOVER PK E TUKW SIGHTLINE HEALTH RECEIPT Permit Number: Status: Applied Date: Issue Date: EL11 -0077 ISSUED 02/01/2011 03/22/2011 Receipt No.: R11 -01280 Initials: User ID: TLS 1670 Payment Amount: $63.00 Payment Date: 06/22/2011 01:48 PM Balance: $0.00 Payee: ROB KINGSLEY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 022756 ACCOUNT ITEM LIST: Description 63.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 Total: $63.00 63.00 doc: Receiot -06 Printed: 06 -22 -2011 Ci, of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 03 -22 -2011 at 09:31:52 03/22/2011 RECEIPT NO: R11 -00555 Initials: JEM Payment Date: 03/22/2011 User ID: 1165 Total Payment: 1,866.70 Payee: MR. JEFFREY J WELLER SET ID: 0322 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D11 -033 EL11 -0077 TOTAL: 283.30 1,583.40 283.30 TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 1,866.70 TOTAL: 1,866.70 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR STATE BUILDING SURCHARGE 000.322.100 000.322.101.00.0 640.237.114 TOTAL: 278.80 1,583.40 4.50 1,866.70 Ciap of Tukwila. • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R11 -00191 Initials: WER Payment Date: 02/01/2011 User ID: 1670 Total Payment: 6,118.39 Payee: WELLER CONSTRUCTION INC SET ID: 020111 SET NAME: SIGHTLINE SET TRANSACTIONS: Set Member Amount D11 -024 EL11 -0077 M11 -016 PG11 -022 TOTAL: 5,347.75 395.85 261.91 112.88 5,347.75 TRANSACTION LIST: Type Method Description Amount Payment Check 709 6,118.39 TOTAL: 6,118.39 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 PLAN CHECK - NONRES 000.345.830 TOTAL: 395.85 5,722.54 6,118.39 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 jr.. (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: c_)(4141 -1,4 �� Type of Inspection: �!cx.) Address: 240 Date Called: Special Instructions: 1 Date Wanted:. Vaa a. . m p.m• Requester: Phone No: Approved per applicable codes. 1 Corrections required prior to approval. COMMENTS: 600A-104.5 tv4z,f (0,4,36"-,.45 c„,piarif 'Inspector: 1�61, 0 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. rate: 07 purl • • • INSPECTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. . • CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: , _ 31G wrJ6 / e of Ins Type Inspection: p ?.boo Address: 2 6 . Date Called: "1' - ovefr,Joi Special Instructions: • • . ,J.,,-. Date Wanted: . g/0/ € Requester: 30 R Ns( To 13f R o i 1, 2-CA Phone No: e f n 446\ 4o'r l d51A-t , Approved per applicable codes. aCorrections required prior to approval. COMMENTS: , "1' - ovefr,Joi ,J.,,-. ,2 Ac. (J,Ji ► 5 44 Root' Rt -iL,f _.: - 30 R Ns( To 13f R o i 1, 2-CA /44444 EaoPr D POI,J e f n 446\ 4o'r l d51A-t , Inspector: Date: 47/61 (i REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 e'ifoO7T ERMIT NO. Project: S4 4E / f % , +�`(- Type of Inspection:7�� �/� Date Called: Address: 20 F Special Instructions: Date Wanted: 7/2.7 41T, Requester: Phone No: KApproved per applicable codes. El Corrections required prior to approval.. COMMENTS: d.4 uAk) r JcoJ �lr2�iw� ��. -fEX acr cr 44.1V - ( ) i Ptl P OtPt4 I " -t.. 5 ¢NLts ra RAF _/la (- .5IPfuric. F Ogna P vtelzS 811fcw JMoby Inspector: 4(1 Date: /II REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be • paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 _ (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 4_ 0V►/ ,4 Type of Inspection: , / Address: nv � , _ !J Date Called: CL . - 6646 PAM( I !►- Special Instructions: Date Wanted: 7 r 7 C° p.m. Requester: Phone No: ElApproved per applicable codes. aCorrections required prior to approval. COMMENTS: ' IR 47 015 r Cfi fS r a� WS Pou-nwJ or sP4.f ("a-Pr kf tPn � CL . - 6646 PAM( I !►- tal1 teritho td Vetti ✓i' ArNto Asia- CbA a.- •,. - X ' (Qvt('rjNr r ` itc' 14sttl,-� i - zircA 1AI Or n,4 gaol A Inspector: Date: 647/11/11 r7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. lei INSPECTION RECORD 6,11- 0011 Retain a copy with permit INSPECTION NO. PERMIT NO. i° • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit (206) 431 -3 ;6, 630 mit Inspection Request Line (206) 431 -2451 �. Project: 5c? fffriela ,,Type of Inspection: 7603 i Address: 4a Date Called: Special Instructions: Date Wanted: 7 `5 ` a.m 1+m• Requester: Phone No: 0 Approved per applicable codes. • . D Corrections required prior to apprc3Val. COMMENTS: tic eAl etc Ititi CeP t-7tec,f-f'r- Inspector: Date: a "cif' REINSPECTION FEE REQUIRED Prior to next inspection. fee must be•• paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection 441 INSPECTION RECORD 1 Retain a copy with permit W 0077 INS ECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 lr-- Project:li ielik gk, dteAtAt Type of Inspection: 00) 7o,5 Address: ..- 2430 461D01/6\ F• Date Called: Special Instructions: Date Wanted: ? 61; Requester: Phone No: ' Approved per applicable codes. Corrections required prior to approval. COMMENTS: 444. GxtbP'( CONLIDaQS, Cr sar4 Apip Kea-Pf Q'J Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. YIYl1i r11/4".i{.Y 4x• S 3'k.: 7"rir‘ • :`9 .S7.,L'dT4it_ "'"1)".7 r'eY . Pr. . -_ = TL -v :N; 71 "-:.■ /6" INSPECTION NO. INSPECTION RECORD Retain a copy with permit ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project: .a4/4 rit. t �� i 17 Type of Inspection: /60 ' 740 Date Called: "3, Special Instructions: Date Wanted: !�! m. Requester: Phone No: LIApproved per applicable codes. 111Corrections required prior to approval. COMMENTS: (QK jlek ,5604 Abp T2oc_._. kool Inspector: VP! Date: Onk l n REINSPECTI('N FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. _.4.4.411ke...3b. ._.s... . ....,,...r,..a�A...1_ INSPECTION RECORD Retain a copy with 641-0077 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Projp ti ( f k Type of Inspection: 704:3 6, Date Called: Special Instructions: Date Wanted: 4 p.m ' Requester: Phone No: EiApproved per applicable codes. • • • n REINSPECTI0i1 FEE REQUIRED. Prior to next inspection, fee must be. paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: $: ; ,.' .-,.•.•-• : . r3 INSPECTION RECORD Retain a copy with permit P RMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 2451 Per Project: ,/ r4 4fl.ii( t- of Inspection: 740 Address:200 6 Date Called: Special Instructions: Date Wanted: gal a. p.m . r Requester: Phone No: ❑ Approved per applicable codes. a Corrections required • • • • • prior to approval. . ,�,'• COMMENTS: I 9 Otio4,6)ti Nur eLdwiltiw, Atoll - coda-4,64a Wel Inspector: Date: 6. r7 REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be ' paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: r3 INSPECTION RECORD Retain a copy with permit 6-A1 _0o77 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 IV_ (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 • Project:Di j- iNk �� Type of Inspection: Dot adli 7 Address: Date Called: Special Instructions: • Date Wanted: ` �� a;asr. Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: JnibtR5L4A 604)JrT6 r�l Cr sir Rocy Inspector: ii":113641(-R, Date: 04 /7-3 ( 1 ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IZ INSPECTION RECORD aikoon Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 :r- (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 = Project: 5aL1'Je 14041- Type of Inspection: 7,03 Address: f , Date Called: Special Instructions: Date Wanted: 10 p rmr�. Requester: Phone No: ElApproved per applicable codes. a Corrections required prior to approval. COMMENTS: qAdt:i uJikai5 it49 A1t•7 CAITlot- v✓At6 /tI414i Dt%N67 Faa►'� cawo I Date: 06/1411( n REINSPECTION FEE REQUIRED. rior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: If INSPECTION NO. INSPECTION RECORD 66 _con Retain a copy with permit .dam _con ERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3 Permit Inspection Request Line (206) 431 -2451 Project:4 artl j�Type 1de of Inspection: 7/3 Address: zoo aweis r Date Called: Special Instructions:' Date Wanted: ■ p.m. Requester: 1/1 Phone No: ❑ Approved per applicable codes. El Corrections required prior to approval. 1" • COMMENTS: tAtiV col4St 7'401 Date: 06/3/11 n REINSPECTION EE REQUIRE . Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: Inspector: I • • '. "‘ /0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 14— (206) 431-36 Permit Inspection Request Line (206) 431-2451 COT/ P RMIT NO. Project: ,,,, doatt ixsf 1414T-i Type of Inspection: 7 I Address: zoo Date Called: ...-'‘ Special Instructions: Date Wanted: Requester: Phone No: Approved per applicable codes. COMMENTS: EJCorrections required prior to approval. A- - xF'i LJ7 RulAfistSfcAtigy cfbAlary Cadtiva-A5 1rki-WM145 6ggiudi>44/8034041 ) 4/c., 3 Date: afrbin ri REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION :RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 x(__(206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: ��� „ 49Type of Inspection: 7`D� Address: ZOO Date Called: Special Instructions. Date Wanted: /DV p.m. Requester: Phone No: LIApproved per applicable codes. Corrections required prior to approval. C'A kr,Y) I 1 COMMENTS: ?Anik,. LA a4D L3i XF?1fM ,:A5icakiNgit evaft l a r+.,S , r1 a1%'t1c s flak: tG C, ka1 1Z1 oc, ?� ge Inspector: r Date: 06 OZ r' next ns inspection. ust b C REINSPECTION FEE REQUIRED. Prior to n p e paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. •INSPECTION RECORD Retain a copy with permit t ( -001 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 r., (206) 431 -36 Permit Inspection Request Line (206) 431 -2451 Project: /G ' f _ Jr 44tAlf Type of Inspection: 7o 5 Address: ��,,` AL+i`�Q,",,ry���^ 6 AcJi E h I. Date Called: Special Instructions: Date Wanted: 5125— a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: . . 141<c)i..-t 11-1120040otir Date: :401 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSPECTION RECORD o Retain a copy with permit -0071 INSPECTION NO. ERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -36 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Project :CJ��I�rlrl:'�� Type of Inspection: ��2., D C) k' - Orn4 rJ /O 1 Address: Date Called: Special Instructions: Date Wanted: � a.m. p.m. Requester: Phone No: EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: A"AASFeletA ' s6C64NRI C5 Rt jah D C) k' - Orn4 rJ /O 1 -r-p4-A610/16 Inspector: r n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 6 INSPECTION RECORD af Retain a copy with permit all - " ` [ INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project 4 �� fA/e* _ _ T1'/'1 C Type of Inspection: 71:003 ^_�� Address: Date Called: Special Instructions: Date Wanted: (7 f a:m: Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: N/•11 • WMMti Ca/ac i,JES( Inspector: Date: 95.1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD ' Retain a copy with permit /+ INSPECTION NO. PERMIT,NO. CITY OF TUKWILA BUILDING DIVISION 62' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 (206) 431 -367 Project:. ll ` '4t l _ _ \s:/NKr errs ! � Type of Inspection: 7 tv Addr�es✓ 200 { ('mow IIr 6 . Date Called: Special Instructions: 1 Date Wanted: 5/i 2_ a.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. . "' COMMENTS: 641), n Loci noiJ 64C&o C44 on! /2-a/Z'a V Petit, tAktity-If4 c A-c i(A4ci - g6.061;- Oct Inspector: Date: I I REINSPECTIONI FEE REQUIRED. Prior to next inspection • fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • INSPECTION RECORD Retain a copy with permit INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1P" 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: 5,pL.'J( 176 N Type of Inspection: 7 3 Address: 2A:44 AtWc(.E Date Called: Special Instructions: Date Wanted: 5 i2 m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. • • - COMMENTS: ?Pt OgWow G�JLi� „Ai Ro�S (3) Aroun+ Inspector: ;i45 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: M r 211 INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. '` • • thi -0071 CITY OF TUKWILA BUILDING DIVISION 12-- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 • - Project:, 4 ft, Ak 4" Type of Inspection: 700/ Address: 240 14D 6*, g Date Called: Special Instructions: Date Wanted: /3 ,....„ p.m. Requester: Phone No: ElApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: rLOON f),(1,5 hob) coAwir- 5-rog.5 ALIA), Inspector: Date: 65103/11 n REINSPECTION E REQUIRED. rior to next inspectio fee must be "—I paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • . • '' •• .. ••• INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -367 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: 760/ Address: vtis te Date Called: Special Instructions: Date Wanted: a.m: Requester: Phone No: ❑ Approved per applicable codes. a Corrections required prior to approval. COMMENTS: TP, 1141)-(8 WNW roibuti, ice) k261- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. -..�_ _.. .. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: ,.• I ikeitzt ‘314tintAle Type of Inspection: 7 ,7 0010".."- Address: zoo 1, ha Veitk I • Date Called: Special Instruction .c.. Date Wanted: 7 ly Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (-AkivAlee? bi-SiGnif o ooPrzi3 likAfsbracritai Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ..... . - • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: //www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 6/1 /0 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # 12' Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: S/ bN ELI nl e. Project Address: x-9-00 /q "i ✓>✓ Contact Person: /Z , I bSL,61-2 Summary of Revision: c hl L C Plan Check/Permit Number: 'L 11 — O0 7 7 P412/1/- E4S -r 774 mow) G•1 11 Phone Number: 6J 57/ '" e a,V i 14.4D -v N b Thaws -(-on (,2O)1A �-I^-�- �C.E c.A L irdf1A * et oci �D fel t'i'c„ i , r,a F -- /-1` /Z'- fL, 7f 4/G '€ V - "z ) 11-7v,ve,r '/Z''s -t- L� / . SAi. tC- ) Pie-A4z s� 61.41 -,1,,, 6 , Geta ■14.4- 4n/7 iii€ -s r Ai/S RECEIVED art Sheet Number(s): IJUN 0 2 2011 "Cloud" or highlight all areas of revision including date of {ey{sion Received at the City of Tukwila Permit Center by: I Entered in Permits Plus on P '44 H:\ApplicationsWonns- Applications On Line\2010 Applications\7.2010 - Revision Submitlal.doc Created: 8 -13 -2004 Revised: 7 -2010 PERM►' L. - • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0077 PROJECT NAME: SIGHTLINE SITE ADDRESS: 200 ANDOVER PK E Original Plan Submittal DATE: 06 -02 -11 Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: k ilding "Division Public Works n Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -07-11 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07 -05 -11 Approved K Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Onili CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL11 -0077 PROJECT NAME: SIGHTLINE HEALTH SITE ADDRESS: 200 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # DATE: 02 -01 -11 Response to Incomplete Letter # Revision # After Permit Issued `DEPARTMENTS: t sion Ling Ivision Public Works ❑ Fire Prevention Structural ❑ Planning Division n ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 02-03 -1 1 Not Applicable El Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-03-11 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: \VII- SITE ADDRESS: p [ PERMIT NO: r �— t l `- ^A I ORIGINAL ISSUE DATE: REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITI S Summary of Revision: 1!-t -k rgons 40rwvi t 'j 'ei1't(/�t- 4 h..r i v e- C�k-c.4 S ad Gl TT rdp u,,.. wee u-e 'a w..�— c,O4 atet I l Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) Contractors or Tradespeople Per Friendly Page • Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name NORTH STAR ELECTRIC INC UBI No. 601034594 Phone 2063291596 Status Active Address 1905 S Jackson St License No. NORTHSE13608 Suite /Apt. License Type Electrical Contractor City Seattle Effective Date 9/28/1987 State WA Expiration Date 9/28/2011 Zip 98144 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NORTHSE193LS NORTH STAR ELECTRIC Electrical Contractor General Unused 6/10/1981 3/31/1989 Archived Electrical Administrator INFORMATION License OSTERDS193JP Name OSTERGAARD, DOUGLAS S Status Active Business Owner Information Name Role Effective Date Expiration Date OSTERGAARD, DOUGLAS Violation Amount 01/01/1980 1/16/2009 FREDERICKS, DOLORES ELECTRICAL CITATION 01/01/1980 $250.00 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 TRAVELERS CAS /SURETY CO OF AME 206085610 05/20/2001 Until Cancelled $4,000.00 04/02/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type Warrant Information Warrants are not filed with the department for this contractor type Infractions /Citations Information Infraction / Citation Date RCW Code Type Status Violation Amount ESLOD00275 1/16/2009 19.28.271 RCW ELECTRICAL CITATION Satisfied $250.00 ESLOD00276 1/16/2009 19.28.161 RCW ELECTRICAL CITATION Satisfied $250.00 EBERA00004 3/1/2006 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 ECERM00570 11/1/2010 19.28.101 RCW ELECTRICAL CITATION Satisfied $1,000.00 EBRIC01866 12/3/2009 19.28.101 RCW ELECTRICAL CITATION Satisfied $250.00 https: // fortress .wa.gov /lni/bbip /Print.aspx 03/22/2011 North Star Electric North Star Electric 1905 S. Jackson St. Seattle, WA 98144 (206) 329 -1596 Fax (206) 329 -9437 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees SEPARATE PERMIT REQUIRED FOR: Mlechanical ❑ Electrical Plumbing Mae Piping City of Tukwila II,.DING DIVISION This room was built to accommodate the data equipment that was to be located in the electric room. It has been relocated to accommodate the relocation of the transformers. The circuits have been relocated. zm Changes this area— The two transformers shown on the roof have been relocated to this area. The power conditioner has been relocated to allow for proper clearances. The receptacles for the data rack have been relocated to a new room. FILE COPY' Permit No. E L 7 Plan review approval is subject to errors and omissions. p p ro =°gal of construction comments does not authorize 1 he violation of any adopted code or ordinance. Receipt of approved Field Copy and coMtiona is adu ledged: By, Date:. City Of 1Ukwila BUILDING DIVISION Revisions v7 �n1 — REVIEWED WITH COMPLIANCE FPA70 - NEC JUN 2 2011 City of .Tukwila BUILDING DIVISION all-- 007 7 0 REVISIONNO1L Drawn Byl RECEIVED JUN 0 2 2011 PERMIT CENTER Scale: 1/V=1' Page No. E -1 Date:6 /2/11 GENERAL NOTES GENERAL NOTES: I. ELECTRICAL INSTALLATION SHALL COMPLY WITH LATEST EDITIONS OF CODE, INCLUDING THE FOLLOWING: 2008 UBC 2007 NEC 2008 UMC 2008 UFC ALL APPLICABLE STATE AND LOCAL CODES. 2. ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, LICENSES, ETC. REQUIRED TO CARRY ON AND COMPLETE THE WORK. 3. PROVIDE ALL LABOR, MATERIALS, TOOLS, PLANT EQUIPMENT, TRANSPORTATION AND PERFORM ALL OPERATIONS NECESSARY FOR ANY REASONABLE INCIDENTAL TO PROPER EXECUTION AND COMPLETION OF ALL "ELECTRICAL WORK" WHETHER SPECIFICALLY MENTIONED OR NOT; ALL AS INDICATED, SPECIFIED HEREIN, AND /OR IMPLIED THEREBY TO CARRY OUT THE APPARENT INTENT THEREOF. 4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED WITH THE UNDERWRITERS' LABORATORIES, INC., SHALL MEET THEIR REQUIREMENTS AND SHALL B EAR THEIR LABEL WHEREVER STANDARDS HAVE BEEN ESTABLISHED AND LABEL SERVICE IS REGULARLY FURNISHED BY THAT AGENCY. 5. ELECTRICAL DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH THE SIZE AND LOCATIONS OF EQUIPMENT ARE SHOWN TO SCALE WHEREVER POSSIBLE, CONTRACTOR SHALL MAKE USE OF ALL DATA IN ALL CONTRACT DOCUMENTS AND VERIFY THIS INFORMATION AT THE SITE. CONTRACTOR SHALL BE RESPONSIBLE FOR LAYING OUT AND INSTALLING HIS WORK TO AVOID INTERFERENCE WITH OTHER TRADES. 6. CONDUCTORS SHALL BE COPPER CONDLCTORS TYPE THWN UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. 7. ALL FLUORESC ENT FIXTURES TO B E LAMPED WITH F032, T8, 3500K LAMPS OR APPROVED EQUAL, AND HAVE AN ENERGY SAVING "A" SOUND RATING ELECTRONIC BALLAST OR APPROVED EQUAL UNLESS OTHERWISE SHOWN. ALL H.I.D. LIGHT FIXTURES SHALL HAVE HIGH POWER FACTOR BALLASTS. 8. FLASH AND COUNTERFLASH ALL ITEMS PASSING THROUGH THE ROOF. 9. WORK SHOWN ON THE DRAWINGS TO BE INSTALLED UNDERGROUND SHALL BE INSTALLED AT LEAST 24" BELOW GRADE. BAC KFILL IN 6" THICK, PROPERLY MOISTENED LAYERS, SOLIDLY PACKED AND IRON TAMPED TO A DENSITY NOT LESS THAN THAT OF ADJAC ENT, UNDISTURB ED EARTH. RESTORE SURFACES, ROADWAYS, WALKS, CURBS, WALLS, EXISTING UNDERGROUND INSTALLATIONS TO ORIGINAL CONDITION IN AN ACCEPTABLE MANNER. 10. THE OWNER RESERVES THE RIGHT TO RELOCATE ALL LIGHTING, OUTLETS AND SWITCHES BEFORE THEY ARE ROUGHED IN AT NO EXTRA COST. 11. ALL EXIT SIGNS TO BE UNSWITCHED. 12. ELECTRICAL CONTRACTOR SHALL VERIFY POWER, CABLE T.V. AND PHONE SERVICES AT AT SITE PRIOR TO BIDDING. SERVICE TO CONFORM TO UTILITY CO. REQUIREMENTS. ELECTRICAL CONTRACTOR SHALL ARRANGE FOR SERVICE INSTALLATION PER UTILTY COMPANY REQUIREMENTS AND PAY ALL CUSTOMER CHARGED SERVICE COSTS. INAMEPI ATES & IDENTIFICATION: INSTALL ENGRAVED NAMEPLATES FOR EACH PANELBOARD, CABINET, DISCONNECT, ETC. NAMEPLATES SHALL BE SECURELY FASTENED TO THE EQUIPMENT WITH #4 PHILLIPS ROUND HEAD CADMIUM PLATED SELF - TAPPING SCREWS, BRASS BOLT, OR WITH A PLASTIC RESIN ADHESIVE GLUE, GOODYEAR "PLIEBOND" OR EQUAL. HVAC UNIT DISCONNECTS: 1. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR FOR EXACT LOCATIONS OF ALL HVAC UNITS, DISCONNECTS AND DEVICES IN FIELD. VERIFY AND CONFIRM THE ACTUAL MOUNTING LOCATION ON THE HVAC UNIT FOR THE DISCONNECT. 2. THE RATING OF THE DISCONNECT SHALL BE SUCH AS TO ENABLE THE LARGEST FUSE SIZE ON THE UNIT NAMEPLATE TO BE INSTALLED IN THE DISCONNECT. PROVIDE FUSES OF TIIIS RATING. 3. FURNISH AND INSTALL ALL LINE VOLTAGE AND LOW VOLTAGE CONDUITS AND LINE VOLTAGE WIRING (LOW VOLTAGE WIRING BY OTHERS) TO HVAC EQUIPMENT AND ASSOCIATED CONTROLS AND DEVICES AS SHOWN ON THE ELECTRICAL AND MECHANICAL PLANS, UNLESS OTHERWISE NOTED. WIRING METHODS: 1. ALL WIRING SHALL BE INSTALLED IN STEEL CONDUITS, CONCEALED IN WALL AND CEILING U.O.N. 2. MINIMUM CONDUIT SIZE SHALL BE 1/2 ". MINIMUM ACCEPTABLE CONDUITS ARE A. GALVANIZED RIGID STEEL. B. GALVANIZED STEEL EMT. C. LIQUID TIGHT STEEL FLEX - FOR FINAL CONNECTION TO OUTDOOR EQUIPMENT. D. FLEXIBLE STEEL CONDUIT - FOR INDOOR FINAL CONNECTIONS TO MECHANICAL EQUIPMENT (NOT TO EXCEED .36 "). E. PVC CONDUIT SCHEDULE 40, UNDERGROUND. WIRING DEVICES UNITS SHALL BE EQUAL TO THE DEVICES SET FORTH HEREIN, IN STANDARD COLORS (BROWN, WHITE, GREY, BEIGE OR IVORY) AS SELECTED BY THE ARC H ITEC T: A, WIRING DEVICES LEVITON # HUBBELL # P & S SINGLE POLE SWITCH 1221 1221 2OAC 1 THREE WAY SWITCH 1223 1 223 20AC 3 DUPLEX CONV. OUT. 15A 5262 5262 5262 DUPLEX GFI CONY. OUT. GF5262 DEVIC E PI ATES: 1. ALL DEVICE PLATES FOR INDOOR USE SHALL B E SMOOTH NYLON OR APPROVED EQUAL UNLESS OTHERWISE NOTED. ALL DEVICE PLATES FOR OUTDOOR USE SHALL BE RAISED METAL. 2. DEVICE COVERS FOR SURFACE MOUNTED BOXES SHALL B E 1/2" RAISED STEEL PLATES. WEATHERPROOF COVERS TO BE SNAP TYPE COVERS. 3. DEVICE PLATES FOR TELEPHONE AND COMPUTER OUTLETS TO BE BY OWNER'S VENDOR. ALL TELEPHONE AND COMPUTER SYSTEM WIRING VENDOR. PROVIDED BY OWNER'S SUPPORTS: 1. FURNISH ALL NECESSARY FOUNDATIONS, SUPPORTS, BACKING, ETC., FOR ALL ELECTRICAL ENCLOSURES, C ONDUITS AND EQUIPMENT. 2. ATTACH ALL BOXES, CABINETS, ETC. TO WOOD WITH WOOD OR LAG SCREWS, TO METAL WITH MACHINE SCREWS OR BOLTS AND TO CONCRETE WITH EXPANSION ANCHORS AND MACHINE SCREWS OR BOLTS. GROUNDING: 1. GROUND AND BOND ALL EQUIPMENT AS REQUIRED BY GOVERNING CODES AND SPECIFICALLY INCLUDING SWITC HBOARD, PANELBOARDS, MOTOR CASES, ETC. WORKING CLEARANCES FOR PANFI S & SWITCHBOARDS 1. COORDINATE WITH OTHER TRADES TO ENSURE CODE REQUIRED WORKING CLEARANCES, ACCESS, ETC, FOR PANELS AND SWITCHBOARDS PER N.E.C. SECTIONS 110 -16 AND .384-4. PANELB OARD S; UNITS SHALL BE FLUSH OR SURFACE MOUNTED AS INDICATED ON THE PANEL SCHEDULE, WITH THE NUMBER AND SIZE OF BREAKERS INDICATED ON THE PANEL SCHEDULE. SINGLE POLE, TWO POLE AND THREE POLE BREAKERS SHALL BE BOLT -ON TYPE. THE PANEL DOORS SHALL HAVE FLUSH TYPE LOCKS, ALL LOCKS SHALL BE KEYED ALIKE AND HAVE TYPEWRITTEN DIRECTORIES INDICATING FIXTURES, EQUIPMENT, OR OUTLETS SERVICED BY EACH BREAKER. ALL BUSSING SHALL B F COPPER. TESTING: 1. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE FREE FROM SHORT CIRCUITS AND IMPROPER GROUNDS. TEST ALL WIRING AND CONNECTIONS FOR CONTINUITY AND GROUNDS BEFORE ANY FIXTURES OR EQUIPMENT ARE CONNECTED AND WHETHER SUCH TESTS INDICATE FAULTY INSULATION OR OTHER DEFECTS, THEY SHALL BE LOCATED, REPAIRED AND RETESTED AT THE CONTRACTOR'S EXPENSE. 2. DEMONSTRATE TO THE OWNER AND THE ARCHITECT, THAT THE ENTIRE INSTALLATION IS COMPLETE, IN PROPER OPERATING CONDITION AND THAT THE CONTRACT HAS BEEN PROPERLY AND FULLY EXECUTED. PROVIDE ALL INSTRUMENTS TO MAKE SUCH TESTS. FIRE ALARM SYSTEM NOTES: A. GFNERAL: 1. PROVIDE A FIRE ALARM SYSTEM EXPANSION FOR THIS BUILDING ADDITION AND THE NEW LINEAR ACCELERATOR SUITE. THE SYSTEM SHALL CONFORM TO ARTICLE 760 OF THE NATIONAL ELECTRICAL CODE AND NFPA 72. 2. UPON COMPLETION OF THE INSTALLATION OF THE FIRE ALARM SYSTEM, A SATISFACTORY TEST OF THE ENTIRE SYSTEM SHALL BE PERFORMED IN THE PRESENCE OF THE LOCAL FIRE MARSHAL. . ALL DEVICES OF THE FIRE ALARM SYSTEM SHALL BE APPROVED AND LISTED BY THE LOCAL STATE FIRE MARSHAL. ALL STROBES ARE TO COMPLY WITH ADA REQUIREMENTS. THE SYSTEM SHALL BE AS MANUFACTURED BY THE SAME MANUFACTUER AS THE EXISTING. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PRODUCING AND PROVIDING FIRE ALARM SUBMITTAL DRAWINGS, DEVICE CUT SHEETS /LISTING PAGES AND CALCULATIONS FOR APPROVAL BY THE OWNER /ENGINEER AND FIRE DEPT. FIRE MARSHAL. THIS SHALL BE DONE IN A TIMELY MANNER SUCH AS NOT TO DELAY THE CONSTRUCTION SCHEDULE. SUBMITTALS SHALL BE IN A MANNER AND TYPE ACCEPTABLE TO THE FIRE MARSHAL. SEE "I" BELOW. 5. A STAMPED SET OF APPROVED FIRE ALARM PLANS SHALL B E ON THE JOB SITE AND USED FOR INSTALLATION. ANY DEVIATION FROM APPROVED PLANS, INC LIJDING THE SUBSTITUTION OF DEVICES, SHALL BE APPROVED BY THE FIRE MARSHAL. 6. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF THE INSPECTOR OF RECORD. 7. A CERTIFICATE OF COMPLIANCE SHALL BE PREPARED BY THE INSTALLER AND GIVEN TO THE FIRE MARSHAL UPON COMPLETION OF THE INSTALLATION. 8. ALL DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE NOT TO BE USED IN DETERMINING ACTUAL CONDUIT ROUTES. 9. NO WORK SHALL BEGIN UNTIL DETAILED PLANS AND SPECIFICATIONS INCLUDING C:SFM LISTING NUMBERS FOR EACH COMPONENT HAVE BEEN REVIEWED AND APPROVED BY THE FIRE MARSHAL. 10. ALL FIRE ALARM CIRCUITS ARE CONTINUOUS FROM DEVICE TO DEVICE_. SPLICES ARE NOT ALLOWED UNLESS IN COVERED JUNCTION BOXES ON APPROVED TERMINAL BLOCKS. 11. ACTUAL HEIGHTS OF SYSTEM DEVICES TO BE PER CODE. F3. WIRING: 1. MINIMUM WIRE SIZE FOR STROBE LIGHTS AND HORNS /MINI -HORNS SHALL BE #12 THWN WCS ORANGE/YELLOW. N COLOR CODE AUDIBLE CABLES BLUE /BROWN AND STROBE 2. COMMUNICATION CABLE PER SYSTEM REQUIREMENTS. � LOI TAGE DROP CAI C ULATIONS• 1. PROVIDE VOLTAGE DROP CALL LILATION S FOR SIGNAL CIRCUITS. WORST CASE VOLTAGE DROP SHALL NOT EXCEED 7% OF NOMINAL SYSTEM VOLTAGE AT THE FARTHEST DEVICE PER SECTION 14.103(b) OF U.F.C. PART 9. INCREASE WIRE SIZE OR ADD MORE SIGNAL CIRCUIT MODULES AS NEEDED TO COMPLY WITI -I THIS REQUIREMENT. BATTERY CAPACITY CALCULATIONS: 1. PROVIDE BATTERY CAPACITY CALCULATIONS TO COMPLY WITH 24 HOUR STANDBY AND 5 MINUTE FULL ALARM CONDITIONS. E DEFERRED APPROVAL: THE ELECTRICAL CONTRACTOR, THROUGH HIS FIRE ALARM SYSTEM SUB CONTRACTOR SHALL PRODUCE AND PROVIDE DESIGN BUILD SUBMITTALS FOR REVIEW BY THE ENGINEER AND FIRE MARSHAL. SEE NOTE #A.4 ABOVE. PROVIDE THE FOLLOWING AS A MINIMUM. EQUIPMENT INFORMATION A. MANUFACTURER'S CUT SHEETS B. EQUIPMENT APPLICATION PER LISTING C. CSFM LISTING PAGES GENERAL INFORMATION: A. APPROPRIATE CODES & STANDARDS INCLUDING EDITIONS. B. TYPE OF SYSTEM OR SERVICE INVOLVED. C. VOICE EVACUATION, IF REQUIRED. D. OPERATIONAL MATRIX E. COMBINATION SYSTEMS (SPECIFIC ADDITIONAL USES) F. HVAC DUCT DECTEC TOR CONNECTIONS FOR ALL HVAC UNITS > 2000 CFM. G. SPECIAL SYSTEM FEATURES. H. REQUIRED PLACARDING. PLANS AND DRAWINGS. A. SCALED FLOOR PLANS INCLUDING NORTH ARROW B. COMPLED TITLE BLOCK WITH SITE ADDRESS, CONTRACTOR'S C -10 LICENSE # CONTRACTOR'S NAME, ADDRESS, PHONE NUMBER. C. OWNER NAME AND ROOM IDENTIFICATION. D. LOCATION OF ALL COMPONENTS INCLUDING END OF LINE DEVICES E. SYMBOL LEGEND, INCLUDING QUANTITIES, MANUFACTURER'S NAME, MODEL NUMBER, ETC. F. IDENTIFICATION OF CIRCUIT STYLES, DESIGNATIONS AND METHODS. G. DESCRIPTION OF ZONES ASSIGNMENTS, DEVICE ADDRESSES. H. COMPLETE BUILDING CROSS SECTION INCLUDING ATTIC SOFFIT OR CEILINGS. I. LOCATION OF SPRINKLER SYSTEM CONNECTIONS J. SPECIFICATIONS AND DETAILS OF WALL PENETRATIONS; FIRE STOPPING, ETC. K. DEVICE MOUNTING HEIGHTS L. POWER SUPPLY DETAILS M. BATTERY CALCULATIONS N. VOLTAGE DROP CALCULATIONS. SINGLE LINE (RISER) DIAGRAMS A. CONDUCTOR INFORMATION, INCLUDING SIZE, STRANDS, INSULATION TYPE, ETC. B. CONDUIT FILL OR NEC REFERENCES. C. LOCATION OF END OF LINE .DEVICES. INSTALLATION NOTES: IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO COMPLY WITH THE CURRENT EDITIONS OF ALL BUILDINGS CODES 2. ON FACTORY PROVIDED BACK BOXES, NO ENLARGEMENTS TO THE STANDARD KNOCKOUTS SHALL BE MADE, NOR MAY THE INSTALLER ATTACH CONDUIT TO A NON- FACTORY PROVIDED KNOCKOUT WITHOUT THE EXPRESS WRITTEN CONSENT OF THE SIMPLEX TIME RECORDER COMPANY. 3. ALL CONDUCTORS SHALL BE BRADY OR EQUAL LABELED. 4. IT IS THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO MAINTAIN AND UPDATE HIS CONSTRUCTION DRAWINGS WITH A HIGH DEGREE OF ACC URACY. 5. PENETRATIONS OF FIRE -RATED ASSEMBLIES SHALL BE PROTECTED IN ACCORDANCE WITH UBC CHAPTER 7. EXISTING MAIN SERVICE SWITCHBOARD WITH TWO EXISTING 200 AMP METERS FOR SPACE AND ONE THIRD METER AVAILABLE AREA OF IMPROVEMENTS BUILDING POWER PLAN SCALE: 1" = 20' -0" .i °'LRATE PERMIT REQUIRED FOR: IS Mechanical 0 Electrical �IR umbing 11Mas Piping c -,' y of Tukwila DIVISION REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. NOT -: Revisions will require a new plan submittal end may include additional plan review fees. FILE COPY Permit No. ;iv- II. 06 7 7 Piet review approval Is subject to errors and omissions. ;J,) oval of construction documents does not authorize vv:oration of any adopted code or ordinance. Receipt c approved Field Copy and conditions is acknowledged: Date: 3/04- r City Of'iukwita BUILDING DIVISION �REVIEWED.FOI COMPLIANCE WITH NFPA70 -NEC FEB 14 2011 RECEIVED FEB 0 1 2011 City. of Tukwila pERMIT'CENTER BUILDING DIVISION L11 007 7 K: \2011 \O - 100 \CA WashingtonTwo \Sightline Electrical.rvt ELECTRICAL SITE PLAN r REVISIONS BY W W 3 1 • U Z z 0 U z 0 U W V) 0 z_ J W V) oes J LLJ W U z 0 U '- w OD 4� � U w N 3 " U •o Z 23.O o N Z r� N a X O O COLUMBIA, CA 95310 in V' ❑❑ W z I- to W W W in CO 3 17) W = D i n 1 0 p ❑ U Loin NN W Q k.00a. 7 uJ Z • V":",,, ,79 V) co W • co sz co a_ Q • < O �D < 0 O O N DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 1 SHEETS / REMOVE EXISTING 480 VOLT PANEL 75 KVA TRANSFORMER AND 208 VOLT PANEL. EXISTING METERS TO REMAIN IN SERVICE AND CONNECTED TO NEW PANELS. ABANDON EXISTING 480 VOLT PANEL, 45 KVA TRANSFORMER AND 208 VOLT PANEL REMOVE ALL EXISTING LIGHTING OUTLETS, COMMUNICATION OUTLETS, ETC FROM TI SPACE DEMOLITION ELECTRICAL PLAN SCALE: 1/8" = 1' -0" (e) UNIT TO BE REMOVED. DISCONNECT & SEAL PENETRATIONS (e)CONDENSER GENERAL NOTES 1. the contractor shall remove such existing work as called for on the drawings or as required to clear the areas for new construction. *where existing equipment is to be retained /relocated, extreme care shall be taken to prevent damage during the removal and reinstallation. where damage occurs, the equipment shall be replaced or repaired to the satisfaction of the architect, at no additional cost to the owner. 2. all equipment and material removed that is not being reused shall remain the property of the owner and shall be stored or disposed of as directed. 3. remove existing electrical and special systems wiring devices shown dashed or !acted within dashed areas unless noted otherwise. for all removed devices, remove associated wiring /cabling and raceway from device to source unless required to maintain service to devices in adjacent areas. it is the electrical contractor's responsibility to field verify existing branch wiring circuits to be removed and reused. 4. empty backboxes installed within cmu or concrete walls shall be provided with blank coverplates. 5. existing panelboard cabinets to remain shall not be used for other purposes than circuit protection and distribution points and shall not be used as junction or pull boxes. 6. where existing electrical work interferes with new york and where such installations are to remain in use, the installations shall be disconnected, relocated, and reconnected to coordinate with the work indicated within the contract documents. such devices shall be restored to their original operating condition. (e)RTU -1 (e)RTU -3 (e)RTU -2 (E)AC UNIT TO BE DISCONNECT RELOCATED BY THE MECHANICAL CONTRACTOR, RECONNECT TO NEW CIRCUIT SHOWN BY THE ELECTRICAL CONTRACTOR (e)RTU -4 (e) UNITS TO REMAIN BUT RECONNECTED TO NEW PANEL. SEE MECHANICAL CONNECTION PLAN FOR NEW CIRCUITING (e)EF -1 (e)EF -2 0 (e)RTU -5 (e) UNIT TO BE REMOVED. DISCONNECT & SEAL PENETRATIONS (e) UNITS TO REMAIN BUT RECONNECTED TO NEW PANEL. SEE MECHANICAL CONNECTION PLAN FOR NEW CIRCUITING (E)AC UNIT TO BE DISCONNECT RELOCATED BY THE MECHANICAL CONTRACTOR, RECONNECT TO NEW CIRCUIT SHOWN BY THE ELECTRICAL CONTRACTOR DEMOLITION MECHANICAL ROOF PLAN SCALE: 3/32" = 1-0" �Lll� 04T7 REVIEWED. FOR COMPLIANCE WITH NFPA70 - NEC FEB 14 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTEF K: \2011 \0 - 100 \CA WashingtonTwo \Sightline Electrical.rvt ELECTRICAL DEMOLITION PLAN REVISIONS BY J W cn 0 z 0 J W 2 06 J W W U z 0 0 X 0 00 O COLUMBIA, CA 95310 _J 7 0 W 0 0 CO Z W Z 2_ uJ Z I- Q 00 W s co O` W • Q W > Q O=' zs < 0 o� o ~' CV DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. \ OF SHEET 2 SHEETS ■ 132 (aa) HL -6 r J1. (bb) HL -6 B2 (aa) HL -6 J1 (bb) HL-6 0 B2E (aa) HL -5 2E (aa) HL -6`' J1 (bb) HL -6 J1 (bb) HL -5 (aa) L -5 B2 (aa);, HL -6 J1,(bb)[ Al (c) HL3 6 B2 (aa HL -6 0 0 KEY NOTE 1 FIXTURES B2,B2E,J1,AX IN THIS ROOM TO HAVE A DIMMING BALLAST KEY NOTE 3 FIXTURES J1,AX IN THIS ROOM TO HAVE A DIMMING BALLAST B2 (aa) HL -6 J1 (bb) HL -6 X1 HL -3 Al (d) HL-3 ,d X1 HL -3 0 0 .- B2 (aa) .•. J1 (bb) HL -6 HL -6 A)(...(aa) AX (aa) H J1 (b HL- o ®. J1 (bb) HL -5 B2 (aa HL -6 0 0 J1 (bb) HL -5 HL-3 Al (c) Al L-3) ❑ Al L-3) HL -3 Al (d) HL -3 0 Al (c) HL -3 Al (bb) Al (aa) HL -1 HL -1 Al (aa) HL -1- B2 (aa) B2 (aa) HL -1 Hl 1 HL -3 Al (c) HL -3 J1 (d) HL -3 r c,d Tr- a,b Al (a) H L -3 Al (d) B2 (c) HL -3 HL -3 B2 (d) HL-3 0 D3 (bb) KEY NOTE 3, TYPICAL FOR ALL U2,U3,U4 Al (bb) Al (aa) HL -1 HL -1 0 0 Al (b) HL -3 0 . J1 (aa) CD HL -1 0 Al (c) HL -3 c,d Al (aa) A1...(bb)... HL-1 HL -1 3 Al (a) HL -3 J1 (d)` HL3 a,b 0 Al (b) HL-3 Al (a) HL -3 FIXTURES TAGS DENOTE: TYPE (switching) CIRCUIT - NUMBER SWITCHES OF DOUBLE LETTERS ARE LOCAL SWITCHES (eg. aa, bb,cc) SWITCHES OF SINGLE LETTERS ARE CONTROLLED BY LOW VOLTAGE LIGHTING CONTROL PANEL (eg. a,b...) EXIT SIGNS ARE UNSWITCHED AND CONNECTED TO CIRCUIT SHOWN. FIXTURES THAT ARE HALF SHADED INCLUDEAN EMERGENCY BALLAST THAT IS CONNECTED TO THE CIRCUIT, BUT NOT SWITCHED. 0 0 J1 (aa) 0 HL -1 D3 ON ® HL 1 X1 HL -3 Al (b) HL -3[ Al (d) HL-3 0 Al (a) Al (b) HL -3- HL -3 ❑ Al (a) HL -3( OS -.... B2 (c) HL -3 B2 (d) HL -3 0 Al (b) HL -3 Al (a) HL -3 Eb==pzcz D3...(bb)- ...... HL -1 Al (c) HL -3 Al (aa) HL -1 �J1 (aa) HL -1 0 Al (aai) HL -1 RETAIN FIXTURE IN CLOSET (aa) AZ (DE HL -2 HL -2 Al (b) HL -3 KEY NOTE 4 B2 HL J1 (bb) a) HL4 B2 (aa) I-- HL-4 i JI (bb) HL-4 Al (d) HL -3 (bb) HL -2 0 n 0 J 1(bb) -4 (aa) HL -2 0 J1 (bb) HL-4® 0 Al (a) HL -3 B2 H B2)(aa) -4 J1 (d) HL -3 r'S P2 (cc) HL-4: J1 (bb) B2 HL-4; H J ((b4b)� HALLWAYS USE LOW VOLTAGE LIGHTING CONTROLS FOR 3 WAY SWITCHING. PRE -WIRE WITH CABLE AS REQUIRED BY SYSTEM MANUFACTURER. INSTALL IN CONDUIT IN WALLS AND OPEN ABOVE CEILING Al (c) HL-3 0 B2 (aa) HL -2 (bb`) HL-4 a) 4 0 A2 (bb) I I A2 (aa HL -2 HL -2 LOW VOLTAGES e,f,g 0 .. J1 (f):y.T J1 (f) HL -7 HL -7 H ® HL -7.. El ®„ , ` g 0 ;i 1,(fl (f) ;! -7, rA HL -7 • ; . Al (e) HL-7 P1 (g HL -7 Al (e) HL -7 Al (e) HL -7 Al (e) HL-7 X1 HL -7 Al (e) HL -7 KEY NOTE 1 & 2 - Al (e) $ PC HL -7 ❑ Al (e) 11 1 HL -7 KEY NOTE 2 APPLIES TO THE "Al" FIXTURES IN THIS ROOM LIGHTING PLAN E3 SCALE: 1/8" = 1' -0" KEY NOTE 4 Lighting Fixture Schedule Type Mark Lamp Description Manufacturer Model Apparent Load Al 2 -F32T8 2'x4' 2 LAMP FLUORESCENT LIGHTING FIXTURE. ELECTRONIC BALLAST, PARABOLIC LOUVER LITHOANI #2PM3N- 232 -12 LD -GEB -MVOL T 62 VA A2 2 -F32T8 FLUORESCENT 2'x4' RECESSED DIRECT /INDIRECT TROFFER, (1)2 LAMP LOW PROFILE 10% THD, INSTANT START ELECTRONIC BALLAST, (2)32W 4100K T8 LAMPS, SYMMETRIC METAL DIFFUSER, 90% REFLECTIVE MATTE WHITE POWDER PAINTED FINISH, 120V, GE ULTRAMAX #232- MAX -N /ULTRA BALLAST, F032, 741, ECO SYLVANIA LAMPS LITHONIA 2AV- G- 2 -32 -MD R- 277- GEB10IS 62 VA AX 2 -F32T8 741 ECO 32W FLUORESCENT 2'x4' RECESSED CEILING TROFFER (1) 3 -LAMP LOW PROFILE 10% THD 0 -10VDC ELECTRONIC DIMMING BALLAST, (3) 32W 4100K, T8 LAMPS, COLD ROLLED STEEL HOUSING, POWDER COATED GLOSS WHITE, LUMINOUS SKY LENS INSERT, 90% REFLECTIVE MATTE WHITE POWDER PAINTED FINISH, 120V, ADVANCE MARK VII, 0 -10VDC DIMMING BALLAST FAILSAFE CV- 2- VR- G -C -2- 32 -CL10 -277 -D B-4A 62 VA B2 3 -F017, 741, ECO 10 FLUORESCENT 2x2 RECESSED DIRECT /INDIRECT TROFFER, (1)3 LAMP LOW PROFILE, 10% THD, INSTANT START ELECTRONIC BALLAST, (3)17W 4100K T8 LAMPS, SYMMETRIC METAL DIFFUSER, 90% REFLECTIVE MATTE WHITE POWDER PAINTED FINISH, 120V, GE ULTRAMAX #317- MAX -N /ULTRA BALLAST LITHONIA 2AV- G- 3 -17 -MD R -MVOLT -GEB 10S 55 VA B2E HL -7 SIMILAR TO TYPE "B2" WITH EMERGENCY BALLAST PACK, SENSOR TYPE DEPENDENT, C. IF MULTIPLE CIRCUITS ARE TO BE CONTROLLED 13Y A SINGLE SENSOR, AUXILIARY RELAYS MAY BE USED IN CONJUNCTION WITH A POWER PACK. 55 VA D3 CFL 13 QUAD FLUORESCENT DECORATIVE WALL SCONCE, ETCHED WHITE OPAL GLASS LENS, SATIN NICKEL FINISH, (1)13W QUAD 4 PIN CFL LAMP, 120V FORECAST F5427 -36E1 17 VA J1 CFL 26 FLUORESCENT 6" RECSSED OPEN DOWNLIGHT, IC- RATED, (1) 10% THD INSTANT START ELECTRONIC BALLAST, (1) 26W 4100K TRT CFL LAMP IN HORIZONTAL POSITION, CLEAR ALZAK REFLECTOR, WHITE FLANGE TRIM, 120V VANTAGE AIC6HF1 -26W- E -1 -SCL 34 VA P2 4- F032T8, 741 ECO FLUORESCENT, 8' DECORATIVE DIRECT /INDIRECT PENDANT, (1) 2 LAMP LOW PROFILE 10% THD INSTANT START ELECTRONIC BALLAST, (2) 32W 4100K T8 LAMPS (PER 4' SECTION), PERFORATED STEEL HOUSING, SPECULAR SLOTTED SIDE REFLECTORS, FLAT ENDCAPS, WHITE POWDER COAT FINISH, 120V, GE ULTRAMAX 232 - MAX -N /ULTRA BALLASTS FINELITE #S5P- 8- 2T8 -SC - SPEC - 277 -AC1 8 -FE 114 VA U2 1 -F17 FLUORESCENT UNDERCABINET FIXTURE, SURFACE MOUNTED, BAKED WHITE ENAMEL FINISH, LOW BRIGHTNESS PRISMATIC ACRYLIC LENS, 10% THD INSTANT START ELECTRONIC BALLAST, T8 LAMP, INTEGRAL ROCKER SWITCH, 120V LITHONIA 2UC- 1- 17 -GEB1 01S-SWR 32 VA U3 1 -25W SIMILAR TO U2, 3' IN LENGTH LITHONIA #2UC -1 -25 -120- GEB10S, SWR 32 VA U4 1 -F32T8 SIMILAR TO U2, 4' LENGTH LITHONIA 2UC -1 -32 -120 - GEBIOIS -SWR 34 VA X1 LED COMBINATION EXIT SIGN /EGRESS LIGHT UNIT, 90 MINUTE BATTERY BACKUP, UNIVERSAL MOUNT LITHONIA LHQM SWIRI20/277 ELN 1 VA Low Voltage Relay Schedule Switch ID LOCATION Apparent Load Circuit Number a HALL 434 VA HL -3 b HALL 372 VA HL -3 c HALL 606 VA HL -3 d HALL 646 VA HL -3 e RECEIPTION 861 VA HL -7 f RECEIPTION 272 VA HL -7 g RECEIPTION 200 VA HL -7 1. ALL T8 FLUORESCENT BALLASTS TO BE 120V. ELECTRONIC 149E THD INSTANT START (MAXIMUM .88 BF) U.N.O. 2. PROVIDE A 0 -10VDC ELECTRONIC DIMMING BALLAST FOR AU. FLUORESCENT LIGHTING FIXTURES INDICATED TO BE DIMMABLE ON THE PLANS U.N.O. 3. PROVIDE A DISCONNECTING MEANS EITHER INTERNAL OR EXTERNAL TO EACH FLUORESCENT LIGHTING FIXTURE THAT UTILIZE DOUBLE - ENDED LAMP(S) AND /OR CONTAIN BALLAST(S) THAT CAN BE SERVICED' IN PLACE PER NEC ARTICLE 410,73(G), 4. PROVIDE TWO (2) BALLASTS FOR FIXTURES SHOWN ON DRAWINGS INDICATED AS BEING HI -LEVEL SWITCHED. 5. PROVIDE AN EMERGENCY BATTERY PACK FOR LIGHTING FIXTURES SHOWN CROSSHATCHED ON DRAWINGS. 6. PROVIDE FLANGE KITS WHERE FIXTURES ARE INSTALLED IN GYP BOARD CEILINGS, 7. ALL METAL HALIDE FIXTURES 150- -WATTS OR GREATER, SHALL UTILIZE ELECTRONIC OR MAGNETIC PULSE -START BALLASTS. 8. ALL FLUORESCENT LAMPS TO BE LOW MERCURY WITH MERCURY CONTENT LESS THAN 70 PICOGRAMS PER LUMEN -HOUR. 9. REFER TO SPEC SECTION 265100 AND 265600 FOR ADDITIONAL INSTALLATION REQUIREMENTS. 10. ALL LIGHTING FIXTURE FINISHES, MOUNTING OPTIONS, ETC. TO BE APPROVED BY THE ARCHITECT PRIOR TO PURCHASE AND INSTALLATION; NO EXCEPTIONS, GENERAL NOTES 1. Provide all equipment, material, labor, supervision, costs, and services required to install complete and working systems including all items and appearances necessary, reasonably incidental, or customarily included, even though each and every item is not specifically specified or shown. 2. Provide and install all lighting fixtures in accordance with the architectural dimensioned drawings. verify and confirm exact fixture type, quantity#, location, and mounting requirements with architect prior to installation. where a lighting control system is indicated or spefced, the contractor shall coordinate all necessary system components with an approved lighting controls vendor. 3. connect all exit signage and emergency egress lighting fixtures (crosshatched) to nearest 120v. lighting branch circuit serving the Unmediated area, ahead of any switching unless noted otherwise. 4. when double switching is shown, one switch shall control the outer lamp(s), and the other switch shall control the inner lamp(s), unless noted otherwise. 5. rooms containing ceiling mounted occupancy sensor(s) and wall switch to be wired such that the wall switch controls circuit to occupancy sensor /power pack. 6. lower case letters adjacent to light fixtures and switches indicate switchleg. 7. provide and secure all conduit raceways per cec, nec, and local code requirements. all fittings, boxes, sleeves, and penetrations shall be sealed and rated accordingly. 8. refer to architectural drawings for exact locations and elevations of electrical wiring devices. KEY NOTES 1. Provide existing lighting fixture with integral 1400 lumen t8 emergency battery pack and indicator test switch, bodine #b50 -120V or approved equal. 2. Provide existing lighting fixture with (1) 3 -lamp t8 electronic 0- 100vdc dimming ballast (100 % -5% lumen output dimming range); advance mark vii or approved equal. 3. connect undercabinet lighting fixture to nearest 120v. 20a. general receptacle branch circuit serving the immediate area. 4. provide and install 0 -10vdc indoor daylight photosensor, cooper controls #dlc -pd -dim or approved equal; install per manufacturer recommendations. photosensor shall control lighting fixture, or portion thereof, as indicated on the plans. 5. provide and install an override pushbutton switch and interface with timeclock to momentarily control lobby, reception, corridor, and waiting area lighting fixtures during after hours. provide identification on switch coverplate using a machine - generated adhesive label (i.e. "timeclock override ", after hours use only "). sequence of operation shall be as follows: 1. once th switch has been activated by an occupant, it shall provide 60 minutes of override for the specified area(s). 2. 10 minutes before the override period is over, the switch shall alert the occupant by blinking the lighting fixtures it currently controls. 3. when the override period has elapsed, all lighting gixtures shall return to the primary settings of the timeclock. 4. the override switch shall be equipped with a 'lock -out' function, and shall only be active during after hours. 6. provide and install (2) separate 4 -pole lighting contactors, square d #Ig400 or approved equal, and a 365 -day astronomical timeclock, tork dts200a or approved equal, to control interior and exterior lighting fixtures. lighting contactors to be mounted in separate nema 1 enclosures with hinged doors; provide respective identification for each contactor enclosure (i.e. "interior lighting ", "circuits 1Ia- 1,3,5 ") / 7. route lighting circuit, or portion thereof, thru lighting contactor controlled by timeclock. 8. route lighting circuit, or portion thereof, thru lighting contactor controlled via outdoor daylight photosensor. 9. coordinate exact placement of lighting fixture with mep equipment/ductwork/piping to be located in this area. REVIEWED FOR COMPLIANCE WITH NFPA70- NEC FEB 14 2011 City of Tukwila BUILDING DIVISION £LttOo77 '7 RECEIVED FEB 012011 PERMIT CENTER K:\201110- 100 \CA WashingtonTwo \Sightline Electrical.rvt J LIGHTING FLOOR PLAN REVISIONS BY J (.5 Z v w ci) U w -- v-) ° w vin v z Z c: O J 10 LLJ = 03 oS J w LLI fY M U= Z O• • 00 U° COLUMBIA, CA 95310 J Q I1 0 0 �t p W z l pi in 0 w m H P ti in... N N W = O N d00 U ko Q k0oa.L z w coa V Z V Z = W w Z I- V) co < cO W s co IZ Q W Q O� Q �O O CN LIGHTING CONTROLS LEGEND SYMBOL DESCRIPTION MTG HT UNO $OC WALL MOUNTED OCCUPANCY SENSOR, DUAL TECHNOLOGY. LEVTON #OSSMT. OR EQUAL TO (COLOR BY ARCHITECT). 48" AFF $US MOW, OR CY EQUAL SENSORTO, DUAL TECHNOLOGY. CLEVItOEILING N MOUNTED OCCUPAN . CEILING NOTES: 1, ALL. SENSOR LOCATIONS ARE APPROXIMATE. REFER TO MANUFACTURER'S. INSTALLATION INSTRUCTIONS PRIOR TO INSTALLATION. 2. ULTRASONIC CEILING MOUNT SENSORS SHOULD BE LOCATED A MINIMUM OF SIX (6) FEET FROM HVAC SUPPLY /RETURN VENTS. 3. CONTRACTOR IS RESPONSIBLE FOR PROPER SENSITIVITY AND TIME DELAY SETTINGS FOR NON-- ADAPTIVE PRODUCTS, FOLLOWING THE MANUFACTURER'S. RECOMMENDED PLACEMENT, AND FIELD VERIFICATION OF CIRCUITS WITH RESPECT TO POWER PACK. PLACEMENT. 4. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF REQUIRED NUMBER OF POWER PACKS: A. ONE POWER PACK IS 'REQUIRED FOR EACH CONTROLLED CIRCUIT, B. UP TO THREE (3) SENSORS CAN BE WIRED IN PARALLEL TO SINGLE POWER PACK, SENSOR TYPE DEPENDENT, C. IF MULTIPLE CIRCUITS ARE TO BE CONTROLLED 13Y A SINGLE SENSOR, AUXILIARY RELAYS MAY BE USED IN CONJUNCTION WITH A POWER PACK. 5. SENSORS MOUNTED OVER DOORWAYS SHOULD BE PLACED ONE (1) FOOT INSIDE THRESHOLD, 6. REFER TO SPEC. SECTION 260923 FOR ADDITIONAL INSTALLATION REQUIREMENTS REVIEWED FOR COMPLIANCE WITH NFPA70- NEC FEB 14 2011 City of Tukwila BUILDING DIVISION £LttOo77 '7 RECEIVED FEB 012011 PERMIT CENTER K:\201110- 100 \CA WashingtonTwo \Sightline Electrical.rvt J LIGHTING FLOOR PLAN REVISIONS BY J (.5 Z v w ci) U w -- v-) ° w vin v z Z c: O J 10 LLJ = 03 oS J w LLI fY M U= Z O• • 00 U° COLUMBIA, CA 95310 J Q I1 0 0 �t p W z l pi in 0 w m H P ti in... N N W = O N d00 U ko Q k0oa.L z w coa V Z V Z = W w Z I- V) co < cO W s co IZ Q W Q O� Q �O O CN DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 3 SHEETS 1 SEE ONE -LINE DIAGRAM FOR FEEDER INFO ONE 2.5" EMPTY CONDUIT IN CEILING'. SPACE FOR FUTURE INJECTOR SYSTEM. RUN CONDUIT DOWN INSIDE WALL NEXT TO WALL DUCTS. COORDINATE EXACT WALL BOX MOUNTING HEIGHT AT CT CONTROL AND AT CT -SCAN WITH GEMS LB -29 \=' LB -25 LB -29 • i CT SCAN'; LB -25 VAULT LB -29 LB -25 VARIAN WORKSTATION (30A OUTLET) SEE KEY NOTE 6 LB-6-..-LB-6 - LB -6 KEY NOTE 9 LB -21 BIOLITEC LASER KEY NOTE 6 KEY NOTE 10 (LB -12) INSTALL TWO 75 KVA TRANSFORMERS ON ROOF. PROVIDE CURBS':, TO MATCH MECH. INSTALL NEMA 3R WEATHERSHIELDS LB-40 CT SCAN LB-33 CONTROL 135 BLOCK STOR. HALL LB -14.. LB -14 LB-16 #10 LB -18 LB -17 LB -33 KEY NOTE 1 LB -33 133 132 PANEL "HA VAULT CONTROL 131 DOSIMETRY LB -18 LB -33 LB -16 LB-40 111 LB -26 LB -19 PROCEDURE 109 LB -26 LB -30 LB -26 LB -26 GFCI 11 111 LB -30 EXAM 108 LB -30 LB -30 . G.FCI.... 111 Iv ;1! LB -31 111 IOde LB -31 EXAM LB -24 HALL 129 PANEL, "HB" LB -40 LB-40 BLOCK CUTTER LB -13 CHG. CHG. MECH. 128 LB-42 HALL 125 LB-42 IOd MEN'S';. 1; R!1 J FUTURE DEVELOPMENT ALL COUNTERTOP OUTLETS TO BE GFI LB -7 LB -34 BREAKI ROOM DISHWASHER BELOW COUNTER LB -20 MICROWAVE IN CABINETS 137 LB -20 107 LB -31 LB -24 LB -31 BLANKET WARMER KEY NOTE 6 120 C'Nl LB -11 LB -20 LB -11 ❑ LB -23 LB -20 LB -11 / HALL LB -22 LB -11 ELEC. LB -24 KEY NOTE 7 LB-35 LB -37 OFFICE 110 LB -37 LB -39 F CONF RENCE HALL LB -37 LB -11 KEY NOTE 3 104 LB-5 -LB -39 LB -35 . LB -39 LB -35 LB -38 LB -4 LB-4 LB -4 LB -28 101 ADJACENT SUITE N.I.C. FOR EACH COMMUNICATION OUTLET SHOWN, STUB 3/4 "CO TO CEILING SPACE, INSTALL (2)CAT 6 DATA CABLES TO DATA RACK AND ONE CAT 5E CABLE TO PHONE BOARD, LABEL EACH END LB -38 LB -38 FIRE ALARM ANNUNCIATOR PANEL KEY NOTE 11 LB -10 S LB- 41......_ LB -10 111 POWER PLAN SCALE: 1/8" = 1' -0" KEY NOTE 1 LB -8 CLINAC POWER CONDITIONER PROVIDED BY VARIAN, INSTALLED BY ELECTRICAL CONTRACTOR. AUTOMATIC LIGHTING CONTROL PANEL "ILC" PANEL "LB" PANEL "LA" %B ELECTRICAL ROOM \E4\ SCALE: 1/4" =11-0" GENERAL NOTES General Notes 1. Provide all equipment, material, labor, supervision, costs, and services required to install complete and working systems including all items and appearances necessary, reasonably incidental, or customarily included, even though each and every item is not specifically specified or shown. 2. Provide and install an intelligent, performance - based fire alarm system. Devices indicated are a minimum, provide additional devices as required to adhere to all code requirements. Contractor shall commission a licensed fire alarm engineer to provide detailed fire alarm system installation drawings and submit to the local fire marshal for review and comment. Refer to spec section 283100 for additional installation requirements. 3. Provide and install an empty conduit raceway for all telecommunications and security system cabling requirements. Raceways shall be installed from device to nearest accessible ceiling space. In areas without accessible ceiling space or exposed to structure, raceways shall be installed between each device and terminal board. Refer to spec section 283100 for additional installation requirements. 4. Provide and secure all conduit raceways per CEC, NEC, and local code requirements. All fittings, boxes, sleeves, and penetrations shall be sealed and rated accordingly. 5. Provide and install all necessary power connections to equipment per vendor specifications. 6. Refer to site specific medical equipment plans and specifications for additional installation and connection requirements and provide for as required. 7. Refer to architectural drawings for exact locations and elevations of electrical wiring devices. 8. Electrical contractor shall provide and install all exhaust fan control and interlock wiring. 9. Maintain clearances per CEC, NEC, and local code requirements for all installed electrical equipment. Electrical contractor shall provide a'/" scale dimensioned drawing of electrical room equipment layout and submit to electrical engineer for final review. KEY NOTES 1. Provide and install all power, conduit, and necessary control wiring connections to accommodate misc. door hardware (motorized door swings, push plates, card readers, auto - locks, etc.) 2. Provide and install telephone backboard, fire -rated AC grade plywood wall mounted vertically with the bottom at 24" A.F.F. Leave plywood fire- rating stamp exposed in one location. 3. Provide and install flush mounted floor box, Hubbell #S1 DIV1 divider„ #slsp sub - plate, and #slcfcxx coverplate; color /finish to be selected by architect. provide with (1) 120v., 15a. duplex receptacle and (1) tele /data combinations outlet. utilize existing in -slab conduits provided and installed under separate contract. 4. provide and install switched receptacle for garbage disposal located under sink; coordinate installation and connection requirements with manufacturer. 5. refer to gems installation data package for site specific electrical installation and connection requirements. electrical contractor shall provide and install all power conduit and necessary control wiring connections as required. 6. coordinate receptacle requirements with medical equipment vendor and provide accordingly. 7. provide and install power for connection to hvac and plumbing controls (damper actuators, auto -flush valves, etc.); extend circuit wiring and raceway as required. 8. ct -scan flush wall mounted enclosed circuit breaker; refer gems drawing for installation requirements and provide for accordingly. 9. waming light; gems #wziabww- of -xiu. provide a %" empty conduit between warning light and relay junction box. relay junction box (12 "H x 12 "W x 6 "D) shall be located in ceiling space. provide and install potter brumfield- prdl ldgo -24 relay in junction box. 10. provide and install power and data for pet scanner (solo it power mim view workstation). coordinate locations of wiring devices with medical equipment vendor and provide for accordingly. 11. coordinate location of fire alarm annunciator panel with local fire marshal prior to installation. KEY NOTE 2 ID- DATA RACK TELEPHONE TERMINAL BOARD 3/4 "x4'x8' FIRE ALARM CONTROL PANEL GROUND BUS NEMA L5 -30 VARIAN SERVER LB -15 ;' REVIEWED FOR COMPLIANCE OC NECITH FEB 1.4 2011 City ofTukwita BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER IT CLOSET SCALE: 1/4 "= K:\201110-100\CA WashingtonTwo \Sightline Electrical.rvt POWER FLOOR PLAN REVISIONS BY J U z Z 0 0 v) Z 0 U ci) W V) 0 0 J W Q W W 0 Z 0 0 P.O. BOX 1134 COLUMBIA, CA W 0 0 ct co 0 W z F-m w N� Ct 1- • N4�N W IUtn - m m = r 0 ❑ ❑ U U) N N Q! w Q tO0aa � w z ce W z 2Z = W ti oQ a V) C W WSu 0 V Q N g o-a =u- ca,-,0 X10 w Z F-- • CD W sz CO < ce W > < 0 0 < 0 O O DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 4 SHEETS 1 KEY NOTE 10 KEY NOTE 8 KEY NOTE 9 KEY NOTE 6 \KEY . , NOTE 5 . / t err l.i°r 1 j / / / /(O lKEY NOTE 1 iii �� KEY NOTE 7 { iii /1/ viii I• /// /1/ : KEY NOTE 8 VAULT REFER TO THE GEMS INSTALLATION DATA PACKAGE FOR SITE SPECIFIC ELECTRICAL INSTALLATIONI? REQUIREMENTS. ELECTRICAL COTNRACTOR SHALL PROVIDE AND INSTALL ALL UNDERGROUND /IN -SLAB RACEWAYS, PULLBOXES, ETC. AS REQUIRED .. KEY NOTE 12 VESTIBULE ELECTRICAL CONTRACTOR SHALL SPACE CONDUITS 8" ON CENTER WHERE THEY PENETRATE THE CONCRETE STEM WALLS ABOVE NEW SCHEDULED CONCRETE VAULT FOOTINGS. REFER TO THE STRUCTURAL DOCUMENTS. KEY NOTE 11 'KEY NOTE 3 3/4' CO FOR POWER 1 "CO FOR COMMUNICATIONS KEY NOTE 2 fI1 UNDER FLOOR ELECTRICAL PLAN SCALE: 1/8" = GENERAL NOTES KEY NOTES Connections for two ,br more warning Iighls, usually red colored, incandescent (no fluorescent lighting) are provided. Locate over the door, on the outside of the treatment room, They may be required to blink when the x -ray is on. Verify local'` Y requirements with regional regulatory agencies. For more information, see section 4.7,4.5 "Warning Lights;" Provide one 3' (76) and two 2" (51) conduits tight to the ceiling, adjacent to the mechanical duct opening, to facilitate cable access for future room renovations. Review all vault penetrations with the Physicist of Record. Provide one 2(50) conduit between the pull box at In -Room Monitor and the pull box at Control Console. Depending on the configuration, up to four cables may need to be pulled through this conduit. The length of this cable run shall not exceed 75 feet (22,900). Provide one 7`(50) conduit between Main Circuit' Breaker Panel and Modulator pull box. For information on the signal pull box for the in -room monitor, see section 3.2.1.1. Provide '" (1 3) conduit between warning light(s) and the Relay junction box. Provide four - 4 1100) conduits between Control Console pull box and the Base Frame pull box. The length of this cable run shall not exceed 75 feet (22,900). Provide one 2 "(50) conduit between OBI" Circuit Breaker panel and the Base Frame pull box, 1. Provide all equipment, material, labor, supervision, costs, and services required to install complete and working systems including all items and appearances necessary, reasonably incidental, or customarily included, even though each and every item is not specifically specified or shown. 2. contractor shall coordinate the routing and installation of his work with that of all other trades through the general contractor. in any instances of conflict, systems requiring grade, slop, or structural reinforcement shallhave priority. 3. confirm locations of existing underground utilities or services (electrical, telephone, water, gas, etc.) prior to performing any cutting, trenching, boring, etc. notify engineer immediately in writing for any location where a conflict occurs. 4. provide and secure all conduit raceways per cec, nec, and local code requirements. all fittings, boxes, sleeves, and penetrations shall be sealed and rated accordingly. 5. size and install pullboxes in accordance with cec, nec, and local code requirements. where areas are subjuect to vehicular traffic, provide pullboxes with traffic rated covers; label pullbox covers "electrical ". 6. repair areas where digging, trenching, saw cutting, etc. disturbed exising paving, landscaping, etc. to original condition per contract document requirements. 7. refer to site specific medical equipment plans and specifications for additional installation and connection requirements and provide as required. 8. cable runs between equipment pullboxes not to exceed 75 feet. conduit runs between pullboxes shall have a minimum of 270 degrees of bends. conduit bend radii shall be a minimum of 6" diameters. For information on the on-board imager main circuit breaker panel, see section 4.3.1. For information on the main circuit breaker panel, see section 4.2.1.1. 1. refer to varian medical systems installation data package for site specific electrical installation requirements. electrical contractor shall provide and install all underground /in -slab raceways, pullboxes, etc. as required. 2. provide and install a round multi - service floor box for future power and telecomm requirements; hubbell #b2527 or approved equal. 3. route (1)3/4" empty conduit and (1) 1" empty conduit in -slab for future power and telecomm requirements; stub -up inside stud wall. 4. route 2: empty conduit underground between control room and vault for future cctv monitoring requirements; stub -up on interior side of stud wall. 5. route (1) 2" empty conduit underground between obi enclosed circuit breaker location and obi pull box for future medical equipment cabling requirements; stub -up inside stud wall. 6. route (1) 2" empty conduit underground between clinac enclosed circuit breaker location and modular pull box for future medical equipment cabling requirements; stub -up inside stud wall. 7. route (2) 4" empty conduits underground between control room and modular pull box for future medical equipment cabling requirements; stub -up on interior side of stud wall. 8. rout (3) 4" empty conduits underground between control room and obi pull box, and between both obi and modular pull boxes for future medical equipment cabling requirements. 9. provide and install a 12 "h x 24 "w x 10 "d pull box in -slab for future medical cabling requirements. 10. provide and install a 18 "h x 24 "w x 10 "d pull box in -slab for future medical cabling requirements 11. location of future clinac and obi flush wall mounted enclosed circuit breakers. 12. location of future 12 "h x 24 "w x 6 "D surface wall mounted pull box. For information on tine signal pull box for the in -roorn monitor, see section 3.2.1.1. For information on the control equipment pull box, see section 3.2.1.2. A 3 "(75) experimental access (physics:) conduit may be required by the Customer. The experimental access conduit is used to periodically monitor radiation in the equipment room. The conduit should be oriented as perpendicular to the isocenter as possible. Provide a locking 6 "x6 "(150x150) access door at the conduit termination's. Review all vault; penetrations with the Physicist of Record. Provide two 4 "(100) conduits between the Control Console pull box and the Modulator pull box. The length of this cable run shall not exceed 75 feet (22,900).. The Modulator pull box is recessed into the floor slab and shall be 18" x 24" x 10" deep (450 x 600 x 250). See "Modulator Cabinet" drawing for pull box location. The cable access to this box shall be similar to Base Frame Cable Access Details. Provide two 2 "(50) conduits between the Modulator pull box and the Relay junction box. Verification of appropriate utility and cable access is the responsibility the Customer. Selection of the appropriate cable access method is determined by site-specific conditions and Customer preference. The standard bottom cable access details are appropriate for the majority of installations. Side access conduit details are included for installations with sub - floor clearances of at least 24"(610). Duct access details are included: for installations with minimal subfioor clearance. All conduits or cable ducts must be suitably sealed and protected to keep them clean and dry. CONDUIT IN FLOOR E5) SCALE: 12" =11-0" Provide adequate clearance for typical conduit radius of six time the diameter. Conduit bends shall not exceed 270 degrees per cable run. Route all room penetrations as perpendicular to the isocenter;as possible . to avoid radiation scatter. Verify all room penetrations with the, Physicist of Record. ELII The Relay junction box shall be 12 " x 12" x 6" deep (300 x 300 x 150). Locate box above finished ceiling (if accessible) near the Modulator Cabinet. Provide three 4"(100) conduit between the Base Frame pull box and the Modulator pull box. The length of this cable run shall not exceed 75 feet (22,900). Exposed grid ceilings allow for access to the overhead laser and relay junction box without the use of access doors. Major service at the equipment Stand is simplified where there are removable ceiling tiles. Coordinate the layout of ceiling tile to insure that ceiling support system shall not interfere with overhead laser positioning light beam port. As no connections are made at this location, many regulatory agencies do not require a Base Frame pull box. If a pull box is not used, keep this area free of grout If required, provide a 12" x 24" x 10" deep (300 x 600 x 250) Base Frame pull box. Top access is required and the box shall extend Y2113) above concrete: NOT TO _ ICE -tai EVIEWED FOR COMPLIANCE WITH NFPA70 -NEC FEB 14 2011 City of Tukwila RECEIVED 0 FEB 012011 PERMITCENTER K:\201110- 100 \CA WashingtonTwo \Sightline Electrical.rvt UNDERFLOOR ELECTRICAL PLAN r REVISIONS BY J U z z O U v I z O U V) W (1) 0 0 W c= F-- J W W U z 0 U v w ' o 4 L., 03 X d o z 28 0 0 00 m Z 1n o-7� o� 0 COLUMBIA, CA 95310 w ce u W I Q U z w w 1- cn I to Z W co UZZ = W • " n°. E nnN V 0ccb C o� a N W1c 0XzE o co v, y 4 z .r W w Z 41\777,1 I— • 00 W sz CO W Q CZ W. > < O o� zs < 0 O 0 I- N DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 5 SHEETS 160.6501 165.1421 208VAC,3Ph,60Hz Power Supply 480VAC,3Ph,60Hz Power Supply 1'20VACOPh.60Hz Power Supply VARIAN MEDICAL SYSTEMS ELECTRICAL CONNECTION REQUIREMENTS A. MAKE ALL CONNECTIONS UNDER VARIAN SUPERVISION TO MODULAR PATCH PANEL PER THE INTERCONNECTION WIRING DIAGRAM. B. REVIEW CONNECTIONS AND EQUIPMENT FUNCTION WITH THE VARIAN INSTALLER. C. FOR CONDUCTORS FOR LISTED ITEMS INCLUDES 12' -0" INSURE THAT ROUGH -IN O LEFT COILED IN PULL BOXES. D: ROUTE ALL SYSTEM POWER FROM POWER SOURCE THROUGH THE MAIN CIRCUIT BREAKER PANEL E. SUPPLY AND CONNECT PHASE, GROUND AND NEUTRAL POWER SUPPLY WIRES. F. SUPPLY AND CONNECT WIRING FOR UNDER VOLTAGE RELAY, "BEAM -ON LIGHT, DOOR INTERLOCKS, EMERGENCY -OFF SWITCHES, POSITIONING LASER RELAY AND ROOM LIGHTS RELAY. G. BUNDLE ALL WIRING IN CONDUITS SHARED BY VARIAN CABLES. H. PULL VARIAN - SUPPLIED CABLES PER THE VARIAN IDP. I. CABLE RUNS BETWEEN EQUIPMENT PULL BOXES NOT TO EXCEED 75 FEET. CONDUIT RUNS BETWEEN PULL BOXES SHALL HAVE A MAXIMUM OF 270 DEGREES OF BENDS. CONDUIT BEND RADII SHALL BE A MINIMUM OF 6' DIAMETERS. 10.353 60.359 60.528 Customer Supplied Main Circuit Breaker Panel 166.066166.063 Varian 60.360 60.066 Supplied Modulator Cabinet 21.209 UVR Erergency+ -Off UVR Emergency-Off Spare 3 Phase Input Power To Clinac Neutral (50. Hz) Ground Stud In Modulator OBI Circuit Breaker Panel 166.171 Clinac Stand 3 Phase input Power To Stand 60.232 KEY NOTES 1. refer to varian medical systems installation data package for site specific electrical installation and connection requirements. electrical contractor shall provide and install all power, conduit, and necessary control wiring connections as required. 2. existing (1) 2" underground conduit (provided and installed under separate contract) between control room and vault for monitoring requirements. provide surface mount junction box(es) below counter per medical equipment vendor specifications. 3. existing (1) 2" underground conduit (provided and installed under separate contract) between obi enclosed circuit breaker location and obi pull box for medical equipment requirements. 4. existing (1) 2 " underground conduit (provided and installed under separate contract) between clinac enclosed circuit breaker location and modular pull box for medical equipment requirements. 5. existing (2) 4" underground conduits (provided and installed under separate contract) between control room and modular pull box for medical equipment requirements. 6. existing (3) 4" underground conduits (provided and installed under separate contract) between control room and obi pull box, and between both obi and modular pull boxes for medical equipment requirements. 7. existing in -slab 12 "hx24 "Wx10 "D pull box (provided and installed under separate contract) for medical equipment requirements. 8. existing in -slab 18 "Hx24 "wx10 "d pull box (provided and installed under separate contract) for future medical equipment requirements. Customer 4 Supplied 62.03 l Loser Line -VAC In Neutral In Neutral Out Varian 60.060 Supplied 60.360 1 L Laser Line -VAC Out .D Room Lights -VAC In 0 Neutral In -0 Neutral Out 0 Room Lights -VAC Out Ground Stud 0 120 VAC Emergency» -Off' 120 VAC Emergency -Off 60.530 Dedicated Circuit Breakers 66.040 Control Console Power Receptacles 69,051 169.0511 2 WIRING SCHEMATIC E6 SCALE: 12" = 1' -0" In -Room Safety Devices 6! 708 69.051 ©O • 00 0 0 64.482 ❑ VDC Emergency-Off © Spare Emergency -Off © Spare Emergency -Off 0 VDC Emergency -Off ® VDC Door Interlock Q VDC Door Interlock 0 Optional Neutron Door Interlock-Out Ci optional Neutron Door Interlock --In 0 VAC Door Interlock 0 VAC Door Interlock Warning Lights -VAC In Neutral -in Ground am -Off Light am -0n Light ear Ready Light OBI X-Ray ON - OBI Generator On - OBI 0 cI 0 9. door control panel provided by medical equipment vendor and installed by electrical contractor. provide all power, conduit, and necessary control wiring connections to accommodate misc. door hardware (motorized door swings, interlock switches, push plates, etc.) coordinate installation and connection requirements with medical equipment vendor. 10. clinac and obi flush wall mounted enclosed circuit breakers; refer to varian medical systems drawings for installation requirements and provide for accordingly. install relay junction box (rjb) gexpro catalog #vrjb -c3. locate rjb above ceiling. coordinate 11. provide and y 1 (1 ) 9 P 9 J 1 9 specific requirements with vendor. ge supply (800) 200 -9760 or (317) 554 -3876. 12. provide and install a 12 "hx24 "wx6 "d pull box surface mounted on wall below counter. 13. provide and install (2) 2" empty conduits above ceiling between vertical wall duct and relay junction box. 14. provide and install a 24"wx6"d vertical wall duct; connect to floor pull box with (2) 4" empty conduits and (2) 2" empty conduits. 15. provide and install a junction box with (1) 1" empty conduit routed to vault control room for future cctv cabling requirements. 16. warning light; dual -lite dex series or approved equal. provide a1/2" empty conduit between warning light and relay junction box. relay junction box (12 "h x 12 "w x 6 "d) shall be located in ceiling space. provide and install potter brumfield -prdl ldgp -24 relay in juction box. 17. provide a 1" empty conduit between relay junction box to laser positioning lights, emergency - power -off switches, and door interlocks. 18. provide mushroom type emergency -off push button switches (normally closed. manually reset). coordinate with vendor for specific requirements. ge supply (800) 200 -9760 or (317) 554 -3876. THRU CLINIAC POWER CONDITIONER SEE ONE -LINE DIAGRAM FOR FEEDER SIZE GENERAL NOTES IV 1. Provide all equipment, material, labor, supervision, costs, and services required to install complete and working systems including all items and appearances necessary, reasonably incidental, or customarily included, even though each and every item is not specifically specified or shown. 2. Provide and install an intelligent, performance -based fire alarm system. devices indicated are a minimum, provide additional devices as required to adhere to all code requirements. contractor shall commission a licensed fire alarm engineer to provide detailed fire alarm system installation drawings and submit to the local fire marshal for review and comment. 3. provide and install an empty conduit raceway for all telecommunications and security system cabling requirements. raceways shall be installed from device to nearest accessible ceiling space. in areas without accessible ceiling space or exposed to structure, raceways shall be installed between each device and terminal board. 4. provide and secure all conduit raceways per nec and local code requirements. all fittings, boxes, sleeves, and penetrations shall be sealed and rated accordingly. 5. provide and install all necessary power connections to equipment per vendor specifications. 6. refer to site specific medical equipment plans and specifications for additional installation and connection requirements and provide for as required. 7. refer to architectural drawings for exact locations and elevations of electrical wiring devices. 8. electrical contractor shall provide and install all exhaust fan control and interlock wiring. DOOR PUSHBUTTON KEY NOTE 9 ■ KEY NOTE 17 I KEY NOTE 5 KEY NOTE 17 KEY NOTE 4 KEY NOTE 8 LC- 9,11,13 LC -6 WARNING LIGHT KEY NOTE 16 KEY NOTE 15 0 KEY NOTE 15 KEY NOTE 3 KEY NOTE 6 KEY NOTE 7 LC 5 LC -10 EMERGENCY POWER OFF, KEY NOTE 18 KEY NOTE 12 KEY NOTE 14 KEY NOTE 13 KET NOTE 11 EMERGENCY POWER OFF KEY NOTE 18 III I WARNING LIGHT KEY NOTE 16 KEY NOTE 17 LC -12 KEY NOTE 10 LC -14 LC -16 LC -16 LC -16 LC -14 LC -15 KEY NOTE 15 LC -17 LC -17 LC -14 11, LC -15 KEY NOTE 151 WARNING LIGHT KEY NOTE 16 EMERGENCY POWER OFF KEY NOTE 18 KEY NOTE 17. IILC-4 U LC -5 @D REVIEWED FOR COMPLIANCE WITH NFPA 70 FEB 14 2011 KEY NOTE 15 111 LC-4 City o Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER ENLARGED VAULT PLAN E6 j SCALE: 1/4" = 1' -0" K:12011 \0- 100 \CA WashingtonTwo \Sightline Electrical.rvt ENLARGED ELECTRICAL FLOOR PLAN r REVISIONS BY U z Z 0 U F- V) Z 0 U P.O. BOX 1134 COLUMBIA, CA 95310 W 1- U W I (.3 4 0 z z 2 W co V Z Z = W _ DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. t OF SHEET 6 SHEETS J Provide convenience phone jacks as required. A phone jack should be provided at any Varian.equtpment. cabinet not Iodated in the equipment room, near the equipment and within Me control equipment casework.. The phone system shall be. operational .prior to the equipment installation. Provide convenience electrical power receptacles as required. See section 5.8.1, CCTV System Deterla. Provide a two -way patient monitodng intercom system. The in -room intercom may be wall andlor ceiling mounted and should be volce- activated or continuous -on. The intercom at the control equipment area should be push- to-taik Provide a signal conduit from the control equipment area and power to the intercom. Refer to the intercom manufacturer's literature for conduit, mounting and instatiatt0nrequirements. Anon.interruptlbie power . source may be required by regulatory code. 16` -0" (4877) The cm -uoard imager Main Circuit Breaker Panel may be flush mounted on, or recessed 18 the wall_ It recessedd, provide a minimum.8" {150) 8110k wall. Locate within sight Of and within 18' -0 ". (3050) of Clinac control equipment casework, Conspicuoustyidentify:as "Disconnect for 0131, Main Circuit Sneaker- recommended G.E Catalog # OBISgA480V (includes 60Amp, three phase - 480V circuit breaker, 60 amp.; 480VOontacbr /120V coil installed In a Lockout/Tagoatsubpanel) or equivalent. The 0.E Catalog # 011160A486V information Is available from the Planning department' web page: vadan camisupport or contact your regional Planning Manager..: Provide 3 "(75) diameter grommeted holes as required at counter and shelf cables (typical).: If possible;----- in order to accommodate on -she Customer preferences and possible changes el equipment configuration, locate and dolt holes after the control equipment has bean arranged on location. A gap or alatsat the back of the counter and shelf lor:ca'ble access In also aocepwble. Provide grounded .4 piexeieeul0al power receptacles for Varian-Control console equipment.. , Locate adjacent to the underside of the counter to provide maximum power cable extension. Varian Medical Systems requires a single network cable outlet (83.45). and recommends en additional three (3) outlets within three (3) feet . of the Control Console. Thn network cable must be a minimum of Category 5e with a minimum bandwidth of 100 Mops, . full duplex t1008aawT); See Gordian 4 :1.5 for more Infarmatbn, Optional Resp. Gating Optional I Workstation 00 00 Clinac' Electronics Cabinet Control Console L. j Cabinet #2 on le Cabinet #1 The Control Equipment pull box shall have a minimum size of 24" x12" x6 " deep . (610 x 300 x 150).. This pull box may be walrmounled or accessed similar to details In Sarre Frame Cable Access Details, Locate this pull box no that the free ends of cables are protected from physical damage and located within 5'411525) of the Clinac Electronics CabineL As no connections are made at this iodation, many ragutatonr agendas o not require a putt box. 2 CONSOLE E7 SCALE: 12"= 11 -0" Provide' additional control a ea storage and workspace as treaded; Typical storage requlremen s include space for films: charts and personal belongings. Provide a. minimum' 3176} air and cable space at sides, top and rear of all computers. and Monitore For lnfortadan on:csrpellua and requirements, sea aecgnn 5:4.... The Information shown Is far ALL Clihaelinearacceleratormodels 21000(10). 2300CID, 210X, 23Ex ix, Trilogy and Noodle TX. This control equipment casework design- Is provided an a auftgestion for :possible ocrrtp0nam arrangement only The shelf end counter design shown. to recommended: 'beaeuse i €adoiya for Onaleflmponent placernerd adJuetmentsorralte to salt personal preferarloe and can accommodate future equipment upgrades and additional options.. Optional equipment is often added after the Clinac or has been installed and should be planned for even if they are wiped of the initial- order. The control equipment recadon should be as close to the treatment room door as posstbt;tto provide central.:. over the entrance and reduce the travel distance. CCTV, cabinetry, intercom and phones.. are Customer - supplied Dents, shown on Varian drawings for Illustrative purposes only.1t ls. often desirable to locate the control equipment facing in a dlraction that-atlmvs rite therapists . to visually ogfttrgl the edJacent area, ThIn,laydut;en also redce u the visibility of CCTV monitors for patient pdv0dt+.; Provide vendiat)on sufficient' for removal: of control console air heat toad as follows;: > Canao Electitinire Cabinet >1.0 kW (3,415 Blurhr) Control Console cabinet #1 >2.3-kW O7.085'Bturhr):: Control Console Cebmet'#2 > 1.5 kw {5,123 Btumr):.. >AR1A Opdenworkstation> 0.5 kW (1,707 •Littehrlr. Optional Workstation PC DC NOT SCALE The Main Circuit. Breaker Panel and 0111 Circuit Breaker Panel may be flushmoonled on, or recessed in, wall. If recessed, provide 8 minimum 6"(150) thick well Locate within . sight of and within 10 feet (3050) of Clines . control equipment casework:. Locate Control. Console. Cabinets within 15 feet (4572) of each other: Locate Control Console Cabinets within 8 feet (243 of the control nonsole.0B1/4OITCf6adng: monitors,. Provide grounded 4 Alex electrical power receptactas for Varian control console equipment. Locate adjaoent to the underside.gf Ma counter to provide maximum power cable extensi HE070 -1 Connections for two or more warning lights, usually red colored; incandescent (no fluorescent lighting) are provided. Locate over the door, on the outside of the treatment room. They may be required to blink when the x -ray is on. Verify local requirements with regional regulatory agencies. > "X- RAY ON - warning light (maximum 24vdc @254ma) > "GENERATOR ON - warning light (maximum 24vdc fg250ma) The 24vdc (§250ma signal can be used to control a Potter - Brumfield PRD11DG0- 24,24 Vdc (or equivalent) relay to switch higher voltage warning lights. Typical 1 "cable conduit. Provide a: 90 degree bend in conduit above wall to avoid damage to signal cables. (1)3" C (SPARE) (2)2" C (SPARE) (1)1" C (GATING)" Provide 1t2" (13) conduit between X -RAY warning light(s) and the Relay junction box. On -Board Imager (Optional) Power Supply (typical) 480VAC, 64kVA, BOHz, 3 Ph. + G (N. America) or 400- 480VAC, 60kVA, 50Hz, 3 Ph. + G. See Section 4.3, On-Board imager (OBI) Option Subsystem for complete details: Clime Accelerator Power Supply 208VAC, 45kVA, 60Hz, 3 Ph. + G (N. America) or 360.440VAC, 45kVA, 50Hz, 3 Ph. + N + G. See Section 4.2, Ciinac. Linear Accelerator Subsystem Provide two 4" (100) conduits, tight to the ceiling, adjacent to the mechanical duct opening, to facilitate cable access for future room renovations. Review all vault penetrations with the Physicist of Record: For Information on the main circuit breaker panel, see section4.2.1.1. For information on the on- board imager main circuit breaker panel, see section 4.3.1. For information on the signal pull box for the in-rootn monitor, see section 3.1,1.4. For information on the control equipment pull box, see section 3.1.1.1. Provide four - 4 "(100) conduits between the Control Console pull box and the Base Frarne pull box. The length of this cable run shall not exceed 75 feet (22,900). Provide one 2150) conduit between Main Circuit Breaker Panel and Modulator pull box. In -Roorn Monitor The Relay junction box shall be 12" x 12" x 6" deep (300 x 300 x 150). Locate box above finished ceiling (if' accessible) near the Modulator Cabinet. Provide two 2 "(50) conduits' between' the Modulator pull box and the Relay junction box. Provide network cabling, outlets at all server or workstation equipment locations. All network cabling must be in place and tested prior to equipment installation. Network patch panels, hubs and routers are typically located in a server room or closet. /3 VAULT CONDUIT �E7 SCALE: 12"= 11 -0" Provide one 2 "(50) conduit between the pull box at In -Roorn Monitor and the pull box at Control Console. Depending on the configuration, . up to four cables may need to be pulled through this conduit. The length of this cable run shall not exceed 75 feet (22;900). For information on the signal pull box for the in -room monitor, see section 3.1.1.4. A 3 "(75) experimental access (physics) conduit may be required by the Customer: The experimental access conduit is used to periodically monitor radiation in the equipment room. The conduit shouid be oriented as perpendicular to the isocenter as possible. Provide a locking 6 "x6 "(150x150) access door at the conduit termination's. Review all vault penetrations with the Physicist of Record. Provide one 2 " {50) conduit between OBI Circuit Breaker panel and the Base Frame pull box,. As no connections are made at this location, many regulatory agencies do not require a Base Frame pull box. If a pull box is not used, keep this area free of grout. If required, provide a 12" x 24" x 10" deep (300 x600 x 250) Base Frame pull box. Top access is required and the box shall extend 1 d2 "(13) above concrete. DO NOT SCALE HE069.1 The Modulator pull box is recessed into the floor slab and shall be 18 ",x 24" x 10" deep {450 x 600 x 250). Refer to the "Modulator Cabinet" drawing for pull box location. The cable access to this box shall be similar to Base Frarne Cable Access Details. Provide three 4 "(100) conduit between the Base Frame pull box and the Modulator pull box. The length of this cable run shall not exceed 75 feet (22,901 Provide two 4 "(100) conduits between the Control Console pull box and the. Modulator pull box. The length of this cable run shall not exceed 75 feet {22,900). 1 PAINT FRONT 'LEG RED: A - TELEVISION` HVAC CONTROLS FIRE ALARM SECURITY MUSIC PAINT FRONT LEG BLUE: - CODE BLUE NURSE CALL PAGING PATIENT MONITORING MEDGAS ALARM PAINT FRONT LEG YELLOW: C VOICE DATA DICTATION GENERAL NOTES: 1. SEAL PENETRATIONS THROUGH RATED} WALLS NTH APPROVED SEALANT. 2. SEE VENDOR CABLE ROUTING DRAWINGS. WHERE ROUTE CROSSES CORRIDORS, PROVIDE 1 -12" CABLETRAY FOR CONTENTS OF All. 3 HOOKS. TRAY SHALL BE ONE OF FOUR APPROVED FROM TABLE BELOW. 3. ALL FIRE' WALL PENETRATIONS THROUGHOUT MAIN CORRIDOR SHALL HAVE 3-4" SLEEVES AND ARE TO MATCH COLOR OF 11- HOOKS. ORIENT SLEEVES VERTICALLY AND ALIGN %ITN RESP'EC'TIVE HOOK. EYED NOTES: o CTYP 11/2" B 1/2' J--HOOK CABLE SUPPORT HANGER. CADDY MODEL ,SAT -644 OR B-UNE MODEL 1BH64. ED WALL FINISHED CEIUNG (SEE ARCHITECTURAL. REFLECTED CEILING PLAN.) IN SIXTY FEET OF ANY TELECOMMUNICATIONS ROOM, SPACING FOR THESE iS SHALL BE REDUCED TO 32" CENTERS.. PROVIDE MOUNTING HARDWARE PER MANUFACTURERS RECOMMENDATIONS, SECURE. TO STUDS AT 48" ON- CENTER, PROVIDE BRACING AS REQUIRED OR LOCATE ON METAL STUDS. cot )T3 SB- 17 -12 -F 12 11252 -712 rung :spacing stringer dims 1.5 "x.375" "x.375" 5"x.375" 1.5 "x.375" dims 1.5 "x.37 1 ") 15 "x1. rung shape tubular tubular lnnel tubular std length 120" 119.5 "' 16.5 "' 116.5" TELEPHONE SUPPORT REFER TO SPEC SECTION 270500 FOR ADDITIONAL INSTALLATION REQUIREMENTS. E7 SCALE: 12" =11-0" EL\OO7 7 REVIEWED FOR COMPLIANCE WITH NEPA70 - NEC FEB 14 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER K:1201110- 1001CA WashingtonTwo\Sightline Electricai.rvt VAULT DETAILS REVISIONS BY P.O. BOX 1134 COLUMBIA, CA 95310 0 0 N < N inN i U N I 010 r- H 0 w N N W tDp =X ❑ate Z = W Z v DRAWN RCS CHECKED RCS DATE 10/22/1 0 SCALE AS SHOWN JOB NO. 2010. N. OF SHEET 7 SHEETS J 1 ALL ROOF TOP OUTLETS TOBE WP, GFI RTU.1 HM- 8,10,12 • HM- 13,15,17 RTU -2 LM -27,29 ZD -10 LM -5 RTU -3 HWCP -1 HM- 7,9,11 LM -9 RTU -7 HL- 9,11,13 LM -6,8 EDH -2 LM -16 1 HP -1 LM -19,21 ACC -1 LA- 30,32,34 ne s LM -22,24 LM -10 IRCOMP RTU -5 LM -15 1 EDH -1 MOTORIZED DAMPER CONTROLLED BY THERMO STAT IN ELECTRICAL ROOM. SEE MECHANICAL PLANS FOR CONTROLS CONNECT TO OUTLET CIRCUIT FOR ADJACENT UNIT EF -3 LM -4 » HL- 8,10,12 MECHANICAL EQUIPMENT CONNECTION POWER PLAN SCALE: 1/8" = 1' -0 UNIT NAME UNIT DATA & FEEDER AC -1 480V, 3PH, 20.3 MCA, 30/3 DISC, 30 A FUSES, 3/4 "C- 3 #10 +1 #10 GND AC -2 480V, 3PH, 16.3 MCA, 30/3 DISC, 25 A FUSES, 314 "C- 3 #10 +1 #10 GND AC -3 208V, 1PH, 33.7 MCA, 60/2 DISC, 50 A FUSES, 1 "C- 2 #8 +1 #10 GND ACC -1 208V, 3P1-1, 46 FLA, 100/3 DISC, 90 FLA, 1- 1/2 "C- 3 #2 +1 #8 GND AIRCOMP 120V, 1PH, 1 /3HP, MANUAL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND EDH -1 120V, 1PH, 1.5 KW, MANAUL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #10 +1 #10 GND EDH -2 120V, 1PH, 1.5 KW, MANAUL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #10 +1 #10 GND EF -1 120V, 1PH, 1 /6HP, MANUAL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND EF -2 120V, 1PH, 1 /25HP, MANUAL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND EF -3 120V, 1PH, 1 /4HP, MANUAL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND FC -1 208V, 1PH, 1 A, MANUAL MOTOR DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND HP -1 208V, 1PH, 15A, 30/2 DISC, 20A FUSES, 1/2 "C- 2 #12 +1 #12 GND HWCP -1 120V, 1PH, 1/12HP, MANUAL MOTOR STARTER/DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND RTU -1 480V, 3PH, 16.0 MCA, 30/3 DISC, 25 A FUSES, 3/4 "C- 3 #10 +1 #10 GND RTU -2 208V, 1PH, 21.5 MCA, 30/2 DISC, 30 A FUSES, 3/4 "C- 2 #10 +1 #10 GND RTU -3 480V, 3PH, 16.0 MCA, 30/3 DISC, 25 A FUSES, 3/4 "C- 3 #10 +1 #10 GND RTU-4 208V, 1PH, 17.7 MCA, 30/2 DISC, 25 A FUSES, 3/4 "C- 2 #10 +1 #10 GND RTU -5 208V, 1 PH, 17.7 MCA, 30/2 DISC, 25 A FUSES, 3/4 "C- 2 #10 +1 #10 GND RTU -7 480V, 3PH, 16.0 MCA, 30/3 DISC, 25 A FUSES, 3/4 "C- 3 #10 +1 #10 GND ZD -10 120V, 1PH, MANUAL MOTOR STARTER DISCONNECT, 1/2 "C- 2 #12 +1 #12 GND 6Lil-ron7 REVIEWED FOR COMPLIANCE A �� NBC NFP FEB 14 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER K:\201110- 100 \CA WashingtonTwo \Sightline Electrical.rvt MECH EQUIPMENT CONNECTIONS r REVISIONS BY W r• v)Q� w z� °W - Z ALL# U 0 Illidi p Z - o W R N U� w W =0 ,r) cn = 3 v) cz I__ 1_06 - J 1 • ZQ OW U ~ w ce U Z O U P.O. BOX 1 134 COLUMBIA, CA 95310 4 J W IY [] W • W W Q M to � ~� d OONJ ow _ z Wv1 2 C g E2- § w a °' N W w co 0 Z Wo° V)' -^ (Wz I "ZZ FW a =W c4o DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 8 SHEETS J FIRE ALARM CONTROL PANEL] VAULT CONTROL EMPLOYEE RESTROOM ELECTRICAL r FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM PLAN E9y SCALE: 1/8" = 1' -0" THE FIRE ALARM CONTRACTOR SHALL PROVIDE DUCT SMOKE DETECTORS ON SUPPLY & RETURN DUCTS FOR ALL UNITS. INTERCONNECT THE DETECTORS WITH THE HVAC UNIT SHUT DOWN. DETECTORS TO BE POWERED BY THE FIRE ALARM CONTROL PANEL (e)RTU -1 DSD DSD DSD D DF-1 I WH -1 HWCP -1 (e)RTU -3 (e)RTU -4 DSD DSD W DSD DSD DSD iSD EF -1 -EF -2 AC -3 DSD;.: DSD' • c:c (e)RTU -5 DSD DSD EDH -1 MAU -1 MD DSD v EF -3 :z. AC -1 DSD 'DSD ROOFTOP FIRE ALARM SCALE: 1/8" = 1' -0" ELUOOT7 REVIEWED FOR COMPLIANCE WITH NFPA7 FEB 14 2011 City o .Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMIT CENTER K:1201110- 1001CA WashingtonTwolSightline Electrical.rvt FIRE ALARM PLAN REVISIONS BY J ..,5 v ZQ O > ° W 1111:00 Q m� 00 Ei Et W d pp❑ W z m � w O Et 01 93 W Q N u1i W I D O U N N N IY w • Q tfl0EL uJ Z • • CO CO W CO 0— Q !Y > > O 0 z� QU 0 I— DRAWN RCS CHECKED RCS DATE 1 0/22/1 0 SCALE AS SHOWN JOB NO. 2010. OF SHEET 9 SHEETS J 1 3/4 "C- 3 #10 +1 #10 GND r EXISTING MAIN SERVICE EXISTING 277/480 VOLT 3 PHASE BUS L 2 "C- 4 #3/0 +1#4 GND PANEL "HL" 200/3 ) 200/3 ) 200/3 ) 200/3 ) 200A - 277/480Y, 3 PHASE, 4W BUS, 22000 AIC 30/3 SEE PANEL SCHEDULE FOR LIGHTING CIRCUITS MINIMUM 320KA SURGE SPD CURRENT TVSS RATING EXTERNAL MOUNTED SPD/TVSS UNIT, SQUARE D SURGELOGIC OR APPROVED EQUAL, LOCATE ADJACENT TO MAIN DISTRIBUTION BOAR "MDP ", MINIMIZE DISTANCE AND QUANTITY OF BENDS IN SENSOR WIRING 1 ONE LINE DIAGRAM E1( SCALE: 6" = 1' -0" 125/3 125/3) CT -SCAN ENCLOSED CIRCUIT BREAKER SHALL BE GEMS #E4502AE PANEL "HM" PANEL "HA" 200A - 277/480Y, 3 PHASE, 4W BUS, 22000 AIC 100/3 ) HVAC TIES IN HERE 1 1/2 "C- 4#1 +1 #1/0 GND GROUND TRANSFORMERS PER NEC AND LOCAL CODE REQUIREMENTS. GROUND TO WATER PIPE, BUILDING STEEL & GAS PIPE WITH 3/0 CU 2 "C- 4 #3/0 +1#4 GND 75 KVA TRANSFORM 480/277V, 3PH TO 120/208V,3PH, 4W FOR CONV. POWER 200/3 ) PANEL "LA" PANEL " LB" 2 "C- 4 #1/0 +1#6 GND 150/3 200A - 277/480Y, 3 PHASE, 4W BUS, 22000 AIC 30/3 ) SP /3 ) 1 1/2 "C- 3 #1 +1 #1/0 GND 75 KVA TRANSFORM 480/277V, 3PH TO 120/208V,3PH, 4W FOR CONV. POWER 200/3 PANEL " LC" PANEL "LM" 3/4 "C- 3 #10 +1 #10 GND MINIMUM 320KA SURGE SPD CURRENT TVSS RATING 2 "C- 3 #3/0 +1#4 GND 150/3 ) 480 V L i 1 1/2 "C- 4 #1 +1 #1/0 GND 150/3 208V 60/3 480V J PANEL "HB" 200A - 277/480Y, 3 PHASE, 4W BUS, 22000 AIC 150/3 30/3 ) SPARE SP /3 EXTERNAL MOUNTED SPD/TVSS UNIT, SQUARE D SURGELOGIC OR APPROVED EQUAL, LOCATE ADJACENT TO MAIN DISTRIBUTION BOAR "MDP ", MINIMIZE DISTANCE AND QUANTITY OF BENDS IN SENSOR WIRING 150/3 60/3 110 KVA DUAL OUTPUT (480V, 277/480V) CLINAC POWER CONDITIONER WITH INTEGRAL ISOLATION TRANSFORMER AND TVSS, TRANSECTOR 70 /AV SERIES SUPPLIED BY VARIAN & INSTALLED BY ELECTRICAL CONTRACTOR GROUND TRANSFORMER PER NEC AND LOCAL CODE REQUIREMENTS. GROUND TO WATER PIPE, BUILDING STEEL & GAS PIPE WITH 3/0 CU 2 "C- 4#1/0 +1 #6 GND 1 "C- 4 #6 +1 #10 GND OBI SYSTEM ENCLOSED CIRCUIT BREAKER SHALL BE GEMS #0B160A480V WITH SHUNT TRIP CLINAC MODULATOR ENCLOSED CIRCUIT BREAKER SHALL BE GEMS # 2100CCB150A (US) WITH SHUNT TRIP, UVR- GE24VDC #TEDUV8RS, START BUTTON, 115/24V CONTROL TRANSFORMER AND 1A FUSE. ELl1oo'77 REVIEWED FOR COMPLIANCE WITH NFPA 70 NEC FEB 14 2011 C o Tukwila BUILDING DIVISION RECEIVED FEB 012011 PERMITCENTER K:1201110- 1001CA WashingtonTwo \Sightline Electrical.rvt ONE -LINE DIAGRAM REVISIONS BY J w d U V) �-0 C') Q� I—O N w (� U 7.790 CO O Z J o _ = °3 cn n. 06 J W W U Z 0 U COLUMBIA, CA 95310 Q 0 W 0 0 ARCHITECTURE U z H w w ce In F- ct u0 0 V z cc W z = W _ w Z 051 200 ANDOVER PARK EAST CD co CD tT TUCKWILA, WA DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. OF SHEET 1 0 SHEETS l Branch Panel: PANEL "HM" Location: CONF 104 Supply From: Mounting: Surface Enclosure: Type 1 Notes: Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: Mains Rating: 200 A MCB Rating: CKT HM -1 Circuit Description Trip Pol es HM -3 HM -5 HM -7 HM -9 HM-1 HM -1 RTU -3 AC -2 30 A 30 A 3 3 B Pol es 4432 4432 HM-1 HM-1 HM -1 75 kVA, 277 V/480 V, Three Phase, 4 100 A 3 HM -2 4515 16411 4515 17679 4515 16501 HM -2 HM -2 HM -2 HM -2 HM -3 HM -3 19671 19354 Trip 30 A 100 A Circuit Description RTU -1 75 kVA, 277 V /480 V, Three Phase, 4 CKT HM -2 HM-4 HM -6 HM-8 HM -1 HM -1 HM -1 HM -1 HM -1" HM -2 HM-2 HM -2 HM -2 HM -2 HM -3 HM -3 HM -3 HM -3 HM-3 HM -3 HM-4 HM -3 HM -3 HM-4 HM-4 Total Load: 49460 VA Total 179 A 48834 VA 176 A 49233 VA 178A Legend: Notes: Branch Panel: PANEL "LA" Location: ELEC 105 Volts: 120/208 Wye A.I.C. Rating: 22,000 Supply From: 75 kVA, 277 V/480 V, Three Phases: 3 Mains Type: Mounting: Surface Wires: 4 Mains Rating: 200 A Enclosure: Type 1 MCB Rating: Notes: CKT Circuit Description Trip Pol es A B C Pol es Trip Circuit Description CKT LA -1 FIRE ALARM CONTROL PANEL 20 A 1 100 180 VA # 1 20 A LA-2 LA -3 FIRE ALARM COMPRESSOR 20 A 1 �E i °'SFw"' �x ��ht'�^ � 428 VA 360 VA R 1 20 A IT CLOSET OUTLET LA -4 LA -5 FIRE ALARM BELL 20 A 1 � � � 4 ' f 100 VA 50 VA 360 1 20 A IT CLOSET OUTLET LA -6 LA -7 SPARE FOR FIRE ALARM 20 A 1 0 VA 360 VA y 1 20 A IT CLOSET OUTLET LA -8 LA -9 IT CLOSET OUTLET 20 A 1E 1 360 VA 1 20 A FIRE ALARM CONTROL PANEL LA -10 LA -11 MECHANICAL CONTROLS 20 A 3 �� <m� Power 167 VA 10404 3 150 A PANEL "LB" LA -12 1260 2000 1 20 A 167 10264 LB -13 Power 20 A 1 180 360 VA LA -14 LA -15 - 1 20 A � 167 VA 10744 LB -15 VARIAN SERVER 30 A 1 LA -16 LA-17 360 VA 1 20 A Power LB -16 LB -17 WORK STATION 30 A LA -18 LA-19 q 180 VA 360 1 20 A Power Na LB -19 BIOLETIC LASER 20 A LA-20 LA-21 720 VA ;k, �A t�1 1 F ..... Power LB -20 LA -22 LA-23 1 a ; ; 500 VA �. .�� � � ���� � 1 20 A Power LB -22 LA -24 LA -25 20 A 1, 3 zF �' 720 1 20 A Power LA -26 LA -27 Power 20 A 1 720 720 VA '`° 3 1 20 A LA-28 LA-29 LB -27 Power 20 A 1 720 VA 5520 3 90 A ACC -1 LA -30 LA -31 LB -28 LB -29 Power 20 A 5520 � ���':� � x -- -- - LA -32 LA -33 20 A Power LB -30 F Power 20 A 5520 ® 864 VA -- F -- LA -34 LA 35 20 A Power LB -32 LB -33 Power 20 A LA-36 720 VA 864 VA k� 1 20 A Power LA -38 LA-39 Power 20 A 1 ' a 4�' 4, 720 VA 1864 1 LA-40 LA-41 LB -36 LB -37 Power 20 A 1 900 1080 ,34 LA-42 Total Load: Total 16411 VA 17679 VA 16501 VA Power 137 A 147 A 138 A Legend: Notes: Branch Panel: PANEL "LB" Location: ELEC 105 Volts: 120/208 Wye A.I.C. Rating: 22,00 Supply From: PANEL "LA" Phases: 3 Mains Type: Mounting: Surface Wires: 4 Mains Rating: 100 A Enclosure: Type 1 MCB Rating: Notes: CKT Circuit Description Trip Pol es A B C Pol es Trip Circuit Description CKT LB -1 Power 20 A 1 100 180 VA k =ft' # 1 20 A Power LB -2 LB -3 Power 20 A 1 s„ 360 VA 540 VA y 1 20 A, Power LB -4 LB -5 Power 20 A 1 � � � � � „ � '' f 180 VA 540 1 20 A Power LB -6 LB -7 Power 20 A 1 360 3000 y 1 20 A Power LB -8 LB -9 Power 20 A 1 600 VA 2000 R� �, 1 20 A Power LB -10 LB -11 Power 20 A 1 a 54, F • 1260 2000 1 20 A Power LB -12 LB -13 Power 20 A 1 180 360 VA " g �� 1 20 A Power LB -14 LB -15 VARIAN SERVER 30 A 1 180 VA 360 VA 1 20 A Power LB -16 LB -17 WORK STATION 30 A 1 `: v` $ ` q 180 VA 360 1 20 A Power LB -18 LB -19 BIOLETIC LASER 20 A 1 500 720 VA ;k, �A t�1 1 20 A Power LB -20 LB -21 DOOR POWER 20 A 1 a ; ; 500 VA 720 VA 1 20 A Power LB -22 LB -23 Power 20 A 1, 3 zF 500 VA 720 1 20 A Power LB -24 LB -25 Power 20 A 1 720 720 VA '`° 3 1 20 A Power LB -26 LB -27 Power 20 A 1 ; 720 VA 720 VA 1 20 A Power LB -28 LB -29 Power 20 A 1 � ���':� � x r � as. 720 VA 720 1 20 A Power LB -30 LB -31 Power 20 A 1 720 864 VA F 3 1 20 A Power LB -32 LB -33 Power 20 A 1 720 VA 864 VA k� 1 20 A Power LB -34 LB -35 Power 20 A 1 ' a 4�' , „'r 720 VA 1864 1 20 A Power LB -36 LB -37 Power 20 A 1 900 1080 ,34 �� 1 20 A Power LB -38 LB -39 Power 20 A 1 aEt 3 900 VA 1080 fh 1 20 A Power LB-40 LB-41 Power 20 A 1 Lai ` ` 900 VA 1080 1 20 A Power LB-42 Total Load: Total 10404 VA 10264 VA 10744 VA 87 A 86 A 90 A Legend: Notes: Branch Panel: PANEL "LC" Location: ELEC 105 Supply From: PANEL "LM" Mounting: Surface Enclosure: Type 1 Notes: Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,00 Mains Type: Mains Rating: 200 A MCB Rating: CKT Circuit Description Trip Poi es B C Pol es Trip Circuit Description CKT LC -1 LC -3 LC -5 Power 20 A 1 LC -7 LC -9 LC -11 LC -13 Power DOOR 20 A 20 A 1 3 210 VA 540 VA 20 A Motor LC -2 20 A Power LC-4 900 VA 540 540 VA 167 VA 360 VA 167 VA LC -15 LC -17 LC -19 LC -21 LC -23 LC -25 LC -27 LC -29 LC -31 Receptacle Receptacle 20 A 20 A 1 1 LC -33 LC -35 LC -37 LC -39 LC-41 167 1080 720 VA 540 VA 540 1 20 A 20 A Power Power LC -6 LC -8 20 A Power LC -10 720 1 20 A Receptacle LC -12 20 A OUTLETS LC -14 20 A OUTLETS LC -16 720 VA Total Load: Total 2537 VA 2327 VA 3047 VA 21 A 19A 25 A LC -18 LC -20 LC -22 LC -24 LC -26 LC -28 LC -30 LC -32 LC -34 LC -36 LC -38 LC-40 LC-42 Legend: Notes: Branch Panel: PANEL "LM" Location: ELEC 105 Supply From: 75 kVA, 277 V/480 V, Three Mounting: Surface Enclosure: Type 1 Notes: Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: Mains Rating: 400 A MCB Rating: CKT Circuit Description Pol Trip es C Pol es Trip Circuit Description CKT LM -1 EF -2 15A 210 LM -2 LM -3 EF -1 15A 1 480 VA 696 VA 15A EF -3 LM -4 LM -5 LM -7 ZD -10 20 A 500 VA 12241 2 30 A RTU-4 LM -6 LM -8 LM -9 ROOF OUTLETS 20 A 1 720 VA 864 VA 1 20 A AIR COMPRESSOR LM -1 LM -1 LM -1 LM -1 LM -1 LM -1 EDH -1 20 A 1 LM -1 LM -2 HP- 1 /FC -1 20 A LM -2 LM -2 LM -2 LM -2 LM -3 LM -3 LM -3 LM -3 LM -3 LM -4 RTU -2 30 A 2 1500 1841 2236 3505 3047 1841 1 20 A EDH -2 30 A RTU -5 2236 2537 2 50 A 100 A AC -3 PANEL "LC" LM -1 LM -1 LM -1 LM -2 LM -2 LM -2 LM -2 LM -2 LM -3 LM -3 LM -3 LM -3 LM -3 LM -4 LM -4 Total Load: Total 19671 VA 164 A 17777 VA 148 A 19354 VA 161 A Legend: Notes: Branch Panel: PANEL "HL" Location: CONF 104 Supply From: Mounting: Surface Enclosure: Type 1 Notes: Volts: 480/277 Wye Phases: 3 Wires: 4 A.I.C. Rating: 22,000 Mains Type: Mains Rating: 200 A MCB Rating: CKT Circuit Description HL -1 Lighting HL -3 Lighting Trip 20 A 20 A Pol es HL -5 Lighting 20 A A 1 1638 427 VA C Pol es 1 2190 716 VA 1194 890 Trip 20 A Lighting 20 A Lighting Circuit Description CKT HL -2 HL -4 1 20 A Lighting HL -6 HL -7 LIGHTING 20 A 1 HL -9 RTU -7 30 A 3 HL -11 1334 5623 3 30 A AC -1 HL -8 HL -10 HL -12 HL -13 4432 HL -14 HL -15 HL -16 HL -17 HL -18 HL -19 HL -21 HL -23 HL -25 HL -27 HL -29 HL -31 HL -33 TVSS 30 A 3 0 VA 0 VA HL -20 HL -22 HL -24 HL -26 HL -28 HL -30 HL -32 HL -34 HL -35 0 VA HL -36 HL -37 CT SCAN 125 A HL -39 HL-41 -- Total Load: 43454 VA Total 157 A 42961 VA 155 A 30000 42139 VA 152 A HL-38 HL-40 HL-42 Legend: Notes: REVIEWED FOR COMPLIANCE WITH NFPA 70 - NEC FEB 14 2011 City of Tukwila B ILDING DIVISION ELllOO77 RECEIVED FEB 012011 PERMIT CENTER K:\2011\0- 100 \CA WashingtonTwo \Sightline Electrical.rvt PANEL SCHEDULES REVISIONS 1 BY J U z z O F- L) CZ V) z O U P.O. BOX 1 134 COLUMBIA, CA 95310 J U ce Id 0 C3 W I- U W I- U a 0 z 61 6 14TH STREET 0 z 2 w c z w Z =_ J W� v, Q g Zs co IY 0 W 0 0 O N uggi TUCKWILA, WA DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. t OF SHEET SHEETS J COLUMBIA, CA _J LOW VOLTAGE CABLE 3- CONDUCTOR FOR STANDARD LOW VOLTAGE SWITCH AND 5 CONDUCTOR FOR PILOT LIGHT SWITCH. INSTALL IN CONDUIT IN WALLS AND OPEN ABOVE CEILINGS. CIRCUITS FROM PANEL SEE RELAY SCHEDULE FOR ACTUAL CIRCUITS 1 111 LOW VOLTAGE RELAYS. SEE RELAY SCHEDULE FOR ACTUAL NUMBER OF RELAYS LOW VOLTAGE SWITCHES IN INDIVIDUAL ROOMS. ALSO SERVES AS MANUAL OVERRIDE SWITCH LOW VOLTAGE COMPARTMENT 0 0 0 0 AUTOMATIC SHUTOFF CONTROLS TIME SWITCH CONTROL XFMR I o lo IoI O II 0 CONTROLLED LIGHTS 1 LINE VOLTAGE COMPARTMENT LOW VOLTAGE RELAY CONTROL CABINET SEE BELOW FOR RELAY SCHEDULE TYPICAL SCHEMATIC DIAGRAM: LOW VOLTAGE LIGHTING CONTROLS/ AUTOMATIC SHUT OFF CONTROL PANEL 1. CONTROL PANEL TO BE AS MANUFACTURED BY WATT STOPPER TYPE "SWS ". APPROVED EQUALS ARE ILC LIGHT MASTER, LITHONIA SWITCH KEEPER AND TRIATEK "LP" SERIES. ALL OTHERS REQUIRE PER - APPROVAL BY THE ENGINEER. LIGHTING CONTROLS TO BE PROVIDED: 1. AN AUTOMATIC SHUT OFF CONTROL SYSTEM SHALL BE PROVIDED FOR THE INTERIOR LIGHTING OF THE AREAS NOTED ON THE PANELS IN COMPLIANCE WITH THE ENERGY EFFICIENCY STANDARDS, TITLE 24 PART 6 SECTION 131(d). AN AUTOMATIC TIME SWITCH CONTROL DEVICE SHALL BE INSTALLED TO COMPLY WITH SECTION 131(d)1. THIS DEVICE SHALL BE PART OF A COMPREHENSIVE INTELLIGENT LIGHTING CONTROLLER, COMPLETE WITH TIMERS, KEYPAD, RELAYS, POWER SUPPLY, ETC. AN OVERRIDE SWITCHING DEVICE SHALL BE PROVIDED TO COMPLY WITH SECTION 131(d)2. THE LIGHTING SWITCH FOR INDIVIDUAL ROOMS AND AREAS SHALL ALSO SERVE AS THESE OVERRIDE DEVICES. THE ENTIRE LIGHTING CONTROL SYSTEM SHALL BE WIRED AND PROGRAMMED TO MEET THE ABOVE MENTIONED REQUIREMENTS. 2. ALL LIGHTS SHALL BE SWITCHED ON AND OFF USING MOMENTARY CONTACT, ON /OFF SWITCHES UNLESS OTHERWISE SHOWN. APPROVED ALTERNATES ARE DIGITAL SWITCHES. THEY SHALL ADDITIONALLY BE SWITCHED OFF AUTOMATICALLY THROUGH THE AUTOMATIC SHUT OFF CONTROL PANEL. 3. ALL EXIT SIGNS SHALL BE UNSWITCHED AND NOT PASS THROUGH THE AUTOMATIC SHUT OFF CONTROL PANEL. 3 LOW VOLTAGE AUTOMATIC LIGHTING CONTROLLER E12 l SCALE: 12" = 1' -0" PURPLE PURPLE (+) GREY ( -) PURPLE ( +) 10 VDC CONTROLLED ELECTRONIC DIMMING BALLAST HOT ON /OFF SWITCH I2 -GANG PLATE ELEVATION 5 WALL SWITCH DETAIL E12 SCALE: 12" = 1' -0" NEUTRAL GREY GREY ( -) INDOOR DAYLIGHT PHOTOSENSOR PURPLE (+) 10 VDC CONTROLLED ELECTRONIC DIMMING BALLAST HOT NEUTRAL GREY ( -) 2 DAY LIGHTING CONTROLS 0 VDC CONTROLLED ELECTRONIC DIMMING BALLAST HOT NEUTRAL TO ADDITIONAL 10 VDC CONTROLLED ELECTRONIC DIMMING BALLASTS MAXIMUM OF 50 BALLASTS E12 SCALE: 12" = 1' -0" IMOTION SENSOR IAUTO /OFF SWITCH HOT GROUND NEUTRAL HOT GROUND BLUE] BLUE BLACK WHITE OVERRIDE SWITCH 24 VDC (RED) COMMON (BLACK) CQ'TROL (BLUE) POWER PACK (ABOVE ACCESSIBLE CEIUNG) LIAD TING REQUIRED FOR MULTIPLE VOLTAGES OR 'BI -LEVEL SWITCHING NEUTRAL OCCUPANCY SENSOR SCALE: 12" = 1' -0" OVERRIDE SWITCH 24, VDC (RFD) COMMON (B 4QK)' CONTROL (BLUE)' L___s_ -J ADD -A -RELAY (ABOVE ACCESSIBLE CEILING) 'AUTOMATIC SENSOR I SWITCH LIGHTS - INSIDE I LAMPS EACH FIXTURE MANUAL ON /OFF SWITCH LIGHTS - OUTSIDE LAMPS EACH FIXTURE SCHEMATIC DIAGRAM TEST SWITCH HOT NEUTRAL TEST SWITCH -J o S LIGHTING. LOAD ca 0 J 0 SWITCH LEAD CHARGE CIRCUIT LEAD EMERGENCY BALLAST 3 -LAMP AC BALLAST HOT NEUTRAL 3—LAMP BALLAST INSTALLATION 0 SWITCH LEAD 2 -LAMP AC BALLAST CHARGE CIRCUIT LEAD EMERGENCY BALLAST 1 OR 2 —LAMP BALLAST INSTALLATION EMERGENCY BALLAST WIRING ® SCALE: 12" = 1' -0" OCCUPANCY SENSOR (S) UP TO THREE (3) SENSORS CAN BE WIRED IN PARALLEL TO A SINGLE POWER PACK GENERAL NOTES: 1. LAMP LEADS NOT SHOWN. CONTRACTOR TO REFER TO BALLAST MANUFACTURER'S WIRING DIAGRAMS PRIOR TO ELECTRICAL INSTALLATION. 2. CONTRACTOR TO TEST ALL EMERGENCY FIXTURES TO INSURE PROPER OPERATION. MUST BE FED SAME EMERGENCY BALLAST IRICUII TO INSURE OPERATION IEVIEWED.FOR COMPLIANCE WITH NFPA 70 NEC 4. CHARGING LEADS FOR BATTERY BALLAST MUST BE CONNECTED AHEAD OF ALL LIGHTING CONTROLS (CONTACTORS; RELAYS, SWITCHES, SENSORS, ETC:) FEB 14 2011 SEQUENCE OF OPERATION` City of. Tukwila DURING NORMAL AC MODE - BUILDING DIVISION FIXTURE OPERATES AS STANDARD SWITCHED FIXTURE. NO LAMPS ARE ILLUMINATED WHILE SWITCH IS IN 'OFF' POSITION. ALL LAMPS ARE ILLUMINATED WHILE THE SWITCH IS IN THE 'ON' POSITION. THE EMERGENCY BALLAST IS IN STANDBY /CHARGING MODE. DURING AC POWER FAILURE - EMERGENCY BALLAST IMMEDIATELY SWITCHES TO EMERGENCY MODE, KEEPING 1 OR 2 LAMPS ILLUMINATED FOR A MINIMUM OF 90 MINUTES, REGARDLESS OF SWITCH p TCEHTER POSITION. WHEN AC POWER IS RESTORED, THE EMERGENCY BALLAST AUTOMATICALLY RETURNS TO STANDBY /CHARGING MODE. RECEIVED FEB 01 2011 K :1201110- 1001CA WashingtonTwo\Sightline Electrical.rvt LIGHTING CONTROL DETAILS REVISIONS BY l U z z 0 U z 0 U 06 J W F— w IY U z 0 U X 0 V W 0 C] ri �t 0 W m _in e ig MEP W 4 N N = U in ❑ p - F_ N N N N • w w O I X ❑ a < V z 2 W c Z z = W WLI-ga= Or W a, c gg5T-16 U � s m UP), W d' U C 2 X Z E = 0 §4- °' w Z • • co W r- sz co a_ • Q W > < O J 0 < U O I- N DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. t OF SHEET 12 SHEETS l ARC FLASH SPECIFICATIONS A. SHORT CIRCUIT AND OVERCURRENT COORDINATION PROTECTIVE DEVICE ANALYSIS: SUBMIT SHORT CIRCUIT ANALYSIS TO INCLUDE SHORT CIRCUIT VALUES AT SWITCHBOARDS, DISTRIBUTION BOARDS, PANELBOARDS, MAJOR CONTROL PANELS AND MOTOR CONTROL CENTER LOCATIONS TO VERIFY CORRECT APPLICATION OF EQUIPMENT AIC RATINGS. SUBMIT OVERCURRENT COORDINATION PROTECTIVE DEVICE ANALYSIS WITH RECOMMENDATIONS FOR SWITCHBOARD AND DISTRIBUTION BOARD OVERCURRENT PROTECTIVE DEVICES (CURRENT SEIZING, LONG TIME PICKUP, LONG TIME DELAY, SHORT TIME PICKUP, SHORT TIME DELAY, GROUND FAULT PICKUP AND GROUND FAULT DELAY) TO ILLUSTRATE COORDINATION WITH DOWNSTREAM DEVICES, B. INCLUDE LABELS FOR RECOMMENDED PPE RATINGS FOR ARCFLASH PROTECTION, PER NFPA 70(E), FOR EQUIPMENT LISTED ABOVE, BASED ON SHORT CIRCUIT ANALYSIS. ON LABEL FOR EACH PIECE OF EQUIPMENT, INCLUDE AVAILABLE FAULT CURRENT, FLASH HAZARD BOUNDARY, BREAKER TRIP TIME IN CYCLES, ARC FLASH HAZARD CATEGORY, CAL, /SQ CM AT 18, VOLTAGE RATING SHOCK HAZARD, LIMITED APPROACH BOUNDARY, RESTRICTED APPROACH BOUNDARY, PROHIBITED APPROACH BOUNDARY AND LISTED REQUIRED PPE, INCLUDING ARTICLES. I ARC FLASH REQUIREMENTS Arc Fla hl t Shock Hazard Appropriate PPE Required ARC FLASH AND Appropriate PPE and tools required when working on this equipment. PP 21- 1 -B28-A 30619 A Available Fault Current 2.6 teat Flash Hazard Boundary 6 Cycle Breaker trip time Cataaory 0 5.91 Cal/sq cm at 18" 480 VAC Shock Hazard 42, Limited Approach Boundary 12" Restricted Approach Boundary 1" Prohibited Approach Boundary Required PPE includes: Fabric Safety taeees& Ant Rata." a H atwith Safely' Maki OAK H4 RD 9 Protection Safely Shaaa' March 20Th E1,3 SCALE: 12" = 1' -0" ELECTRICAL LEGEND 0 MOMS 1 0 0 EXIT S = D GFI C F LV OS US 3,4 $D P PC TC 0 J SB T ATS SOLID LINE IS CONDUIT, 1/2 "C- 2 #12 +1 #12 GND UNLESS OTHERWISE NOTED SHORT TICKS = # OF HOTS, LONG TICKS = NEUTRALS, LINES WITH DOTS INDICATE GROUNDS LIGHT FIXTURES RECESSED TROFFER RECESSED CAN HALF SHADED FIXTURES TO HAVE EMERGENCY BATTERY BACKED BALLAST SURFACE MOUNT FLUORESCENT FIXTURE TRACK LIGHTING LINEAR FLUORESCENT SURFACE AND /OR PENDANT FIXTURE WALL MOUNT FIXTURE +7' -6" AFG, U.O.N. EXIT SIGN MOUNT ABOVE DOOR, L = LOW LEVEL, EACH UNIT TO HAVE 90 MINUTE BATTERY BACK -UP EMERGENCY EGRESS WALL MOUNT LIGHT UNIT, 90 MINUTE BATTERY BACK -UP. INSTALL AT +7' -6" U.O.N. COMBINATION EXIT SIGN /EGRESS LIGHT UNIT, 90 MIN. BATTERY BACK -UP CEILING EXHAUST FAN OUTLETS DUPLEX CONVIENCE OUTLET +15" (TO BOTTOM) LETTER DESIGNATES SPECIAL PURPOSE OUTLET S = SHOW WINDOW OUTLET (ABOVE WINDOW/ ON CEILING) D = DISPLAY CABINET OUTLET +72 " (VERIFY WITH DISPLAY) GFI = GROUND FAULT INTERUPTER OUTLET +48" C = ON CEILING F = FLOOR OUTLET, W/ FIRE RATED POKE THRU IN RATED FLOORS LIGHT SWITCH, +48" TO CENTER LETTER DESIGNATES SPECIAL PURPOSE SWITCH LV = LOW VOLTAGE LIGHT SWITCH OS = OCCUPANCY SENSOR WALL SWITCH US = CEILING MOUNT OCCUPANCY SENSOR SWITCH 3 OR 4 = 3 -WAY OR 4 -WAY LIGHT SWITCH D = DIMMMER SWITCH P = PILOT LIGHIT SWITCH PC = PHOTOCELL SWITCH TC = TIME CLOCK SWITCH JUNCTION BOX DISCONNECT ELECTRICAL DISTRIBUTION EQUIPMENT PANELBOARD SWITCHBOARD TRANSFORMER AUTOMATIC TRANSFER SWITCH Legend COMMUNICATION LEGEND COMMUNICATION CABINETS IDF INTERMEDIATE DISTRIBUTION FRAME 1-1 TELEPHONE TERMINAL BOARD COMMUNICATION OUTLETS PHONE +15" TO BOTTOM, W = WALL PHONE +48 ", F = FLOOR, I = INTERCOM DATA +15" TO BOTTOM, F= FLOOR HALF FILLED IS BOTH PHONE AND DATA, F = FLOOR TRIANGLE INDICATED COMMUNICATION OUTLET, LETTER DESIGNATES COMMUNICATION SYSTEM T = TV OUTLET, +15 ", W = +96" \S/ S = SPEAKER OUTLET +96" \v V/ TV M M = MICROPHONE OUTLET +15" FIRE ALARM FIRE ALARM CONTROL PANEL MANUAL PULL STATION +48" TO CENTER a STROBE, +80" ©i • • HORN /STROBE, +80" O SMOKE DETECTOR, (DSD = DUCT SMOKE DETECTOR) SCALE: 1/8" = 1' -0" EL ooY? REVIIWEL) t-uh COMPLIANCE WITH NFPA 70 -NEC FEB 14 2011 City of Tukwila BUILDING DIVISION RECEIVED FEB 01 2011 PERMIT CENTER K:1201110- 1001CA WashingtonTwo\Sightline Electrical.rvt r REVISIONS 1 BY U z z 0 U v I z 0 U A X O 0 COLUMBIA, CA 95310 U Z I- w w I- 1n to �0 N m in at U O I- ln w 0 0 2 m o In 0 CO- 93 Nr in to 0.)63 O N = X a� w Z 200 ANDOVER PARK EAST TUCKWILA, WA 98188 DRAWN RCS CHECKED RCS DATE 10/22/10 SCALE AS SHOWN JOB NO. 2010. N. OF SHEET 1 3 SHEETS